Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1722 W First St - Plan
©2024 2025.02.26PROJECT START: REVISION DATE ISSUED: NOTES: SCALE: AS NOTED CHECKED BY:JM DRAWN BY:JM DATE ISSUED: PROJECT NO.:25-0014 2025/02/26 1722 W 1ST STREET, SANTA ANA, CA 92703 PARKING LOT REPAINT PLANS 111 W JACKSON BLVD., STE 1700, CHICAGO, IL 60604 DESIGN PROFESSIONAL SEAL STATE OF CALIFORNIA CS MASSIE CONSTRUCTION COMPANY INC. HEREBY RESERVE IT'S COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHT IN THESE PLANS, IDEAS AND DESIGNS. THESE IDEAS, DESIGNS AND PLANS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THE TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT WRITTEN PERMISSION FROM REFLECT DESIGN + BUILD GROUP, INC. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS OF THE JOB AND MASSIE CONSTRUCTION COMPANY INC. SHALL BE NOTIFIED IN WRITING OF ANY VARIATIONS FROM THE DIMENSION, CONDITIONS AND SPECIFICATIONS SHOWN BY THESE DRAWINGS. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL STATE AND LOCAL CODES. COPYRIGHT NOTICE: MASSIE ©2025 TITLESHEET & PROJECT INFORMATION PARKING LOT REPAINT PLANS 1722 W 1ST STREET, SANTA ANA, CA 92703 GENERAL NOTES 1. AN APPROVED SET OF PLANS (BUILDING, FIRE SPRINKLER, FIRE ALARM SHOP DRAWINGS, ETC.) SHALL BE ON THE JOB SITE DURING CONSTRUCTION. NO INSPECTIONS WILL BE MADE WITHOUT COMPLIANCE WITH THE ABOVE. 2. ALL METAL STUD PARTITIONS SHALL BE CONSTRUCTED OF METAL STUDS AT 16" O.C. MAXIMUM. SEE PLANS FOR EXCEPTIONS. 3. MAINTAIN A TELEPHONE AND FAX MACHINE WITH WORKING PHONE LINES THROUGHOUT THE PROGRESS OF THE WORK. 4. DRAWINGS ARE NOT TO BE SCALED FOR INFORMATION. 5. CONTRACTOR SHALL PROVIDE FIRE EXTINGUISHERS AND CABINETS WITH REQUIRED SIGNAGE AS DIRECTED BY THE FIRE DEPARTMENT. 6. CONTRACTOR SHALL PROVIDE CONCEALED BLOCKING AS REQUIRED TO SUPPORT/SECURE WALL-HUNG FIXTURES, WALL STANDARDS, BATH ACCESSORIES, ARCHITECTURAL AND MILLWORK ITEMS, ETC. 7. CONTRACTOR'S INSTALLATION OF ALL UTILITIES AND SUBSEQUENT HOOKUP SHALL BE AS NECESSARY TO ASSURE PERFORMANCE WITH UTILITY COMPANY. 8. CONTRACTOR SHALL PROVIDE ACCESS PANELS AS REQUIRED BY PLUMBING, AIR CONDITIONING AND OTHER TRADES, AND AS REQUIRED BY CODES. LOCATIONS TO BE APPROVED BY ARCHITECT. 9. FIRE DAMPERS ARE REQUIRED IF DUCTS PENETRATE THE CEILING OF A FIRE-RESISTIVE FLOOR-CEILING ASSEMBLY, OR PENETRATE FIRE-RATED CORRIDOR WALLS. PROVIDE AS REQUIRED. 10. SIGN CONTRACTOR TO OBTAIN SEPARATE APPROVALS AND PERMITS FROM APPLICABLE GOVERNMENT AGENCIES FOR SIGNS. 11. CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING AND OBTAINING ALL INSPECTIONS AND TESTS REQUIRED TO IMPLEMENT THE PLANS AND SPECIFICATIONS. TESTING AND INSPECTION COSTS BY GENERAL CONTRACTOR. 12. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF WORK AND REPORT ANY DISCREPANCIES TO ARCHITECT. 13. ALL NEW WORK TO BE SQUARE AND TRUE TO THE "REFERENCE LINES", AS SHOWN ON THE PLANS. THE EXISTING STRUCTURE SHOULD NOT BE ASSUMED TO BE SQUARE OR TRUE AND SHOULD NOT BE USED AS A REFERENCE OR CONTROL GUIDELINE FOR LAYOUT UNLESS OTHERWISE NOTED. 14. ALL WORK PERFORMED BY THE GENERAL CONTRACTOR AND HIS SUBCONTRACTORS SHALL CONFORM TO THE REQUIREMENTS OF MUNICIPAL AND STATE LAWS AND ALL OTHER GOVERNING AGENCIES HAVING JURISDICTION, WHETHER OR NOT SPECIFIED HEREIN. 15. THE CONTRACTOR SHALL ERECT AND MAINTAIN AS REQUIRED BY EXISTING FIELD CONDITIONS, THROUGHOUT THE ENTIRE PROGRESS OF THE WORK, ALL SAFEGUARDS AND BARRICADES FOR SAFETY PER O.S.H.A. STANDARDS INCLUDING (BUT NOT LIMITED TO) POSTING WARNING SIGNS, ENFORCING SAFETY REGULATIONS, AND PROTECTION OF PROPERTY. 16. UNLESS OTHERWISE NOTED ALL MATERIALS SHALL BE CONSIDERED NEW AND ARE TO BE PROVIDED BY THE GENERAL CONTRACTOR. 17. THE CONTRACTOR SHALL COORDINATE WORK BETWEEN ALL TRADES ON JOB SITE. 18. G.C. SHALL COORDINATE ALL BUILDING TRADES TO PROVIDE ROUTING AND LOCATION FOR H.V.A.C., PLUMBING, ELECTRICAL, FIRE PROTECTION, STRUCTURAL, ETC. TO PERMIT EXACT LOCATION OF ALL ARCHITECTURAL ELEMENTS. ANY CONFLICTS OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IN WRITING IMMEDIATELY BEFORE PROCEEDING WITH THE WORK. 19. REFER TO PLUMBING AND ELECTRICAL DRAWINGS FOR SCOPE OF ALL UNDERGROUND TRENCHING WORK. GENERAL CONTRACTOR SHALL CUT, PATCH AND REPAIR CONCRETE SLAB AS REQUIRED. 20. ALL WOOD BLOCKING, SHEATHING, SHIMS, LEDGERS, PLATES,ETC. TO BE FIRE-RETARDANT, TREATED WOOD (TYPICAL UNLESS OTHERWISE NOTED). 21. COORDINATE ALL TELEPHONE WORK WITH OWNER'S REPRESENTATIVE AND LOCAL TELEPHONE COMPANY BEFORE STARTING WORK. 22. BEFORE CORE DRILLING STARTS, NOTIFY THE BUILDING MANAGEMENT AND TENANTS OF SUCH WORK. MAKE ALL ARRANGEMENTS AND SCHEDULES OF WORK WITH SAME. PROTECT ALL WALLS, FLOORS, CEILINGS, ETC., THAT ARE ADJACENT TO THE CORE DRILLING OPERATIONS. 23. FOR WOODWORK INSTALLATION. CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE PRIOR TO STARTING WORK. PROVIDE SHOP DRAWINGS TO ARCHITECT FOR APPROVAL OF ALL MILLWORK. 24. ALL FINISHED WORK SHALL BE CONSTRUCTED IN THE MOST CAREFUL AND THOROUGH MANNER IN ACCORDANCE WITH DETAILS, AFTER SHOP DRAWINGS AND THE BEST METHODS KNOWN IN THE INDUSTRY. ALL EXPOSED STRUCTURES SHALL BE FREE FROM MARKS, BLEMISHES, OR DEFECTS OF ANY KIND. PROVIDE ALL CONNECTIONS FOR ELECTRICAL FIXTURES. 25. ALL SURFACES TO BE PAINTED OR TO RECEIVE WALL COVERING SHALL PRESENT A TRUE, SMOOTH, LEVEL FINISH AND SHALL BE CLEANED FREE FROM ALL GRIT, GREASE, DIRT AND LOOSE MATERIALS AND ALL SCRATCHES, CRACKS, OPEN JOINTS, HOLES AND OTHER DEFECTS, SHALL BE PROPERLY CUT OUT, SPACKLED AND BROUGHT TO A SMOOTH EVEN FINISH AND GIVEN A PRIME COAT AS SPECIFIED FOR THE AFFECTED WORK. 26. PROVIDE AND MAINTAIN ADEQUATE PROTECTION FOR ALL FLOORING WORK FOR THE DURATION OF CONSTRUCTION. 27. FOR COMPLETION, ALL WORK SHALL BE CLEANED, REMOVING ALL SPOTS OF ADHESIVE, SURFACE STAINS AND ALL SCRATCHES. 28. SUBMIT TO THE ARCHITECT, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES FOR REVIEW AND APPROVAL AS LISTED BELOW BUT NOT LIMITED TO: - MECHANICAL DUCT WORK LAYOUT - MECHANICAL LOUVERS, DIFFUSERS, FIRE DAMPERS, DUCT DETECTORS, THERMOSTATS, ROOF TOP UNITS, ETC. - SPRINKLER SYSTEM DESIGN WITH HYDRAULIC CALCULATIONS - LIGHTING FIXTURES - EXTERIOR SIGNAGE (GENERAL CONTRACTOR AND OWNER TO COORDINATE) - ELECTRICAL PANELS AND TRANSFORMERS - MILLWORK AND CABINETRY - SAMPLES OF ALL WOOD FINISHES - FAUX FINISHES - MASONRY AND/OR MASONRY VENEER - ORNAMENTAL METALS - CERAMIC TILE - STOCK ROOM SHELVING - DOORS, FRAMES AND HARDWARE - PLUMBING FIXTURES 29. GENERAL CONTRACTOR SHALL NOTE THAT, UNLESS OTHERWISE AGREED IN WRITING WITH THE ARCHITECT, SHOULD GENERAL CONTRACTOR AND/OR HIS SUBCONTRACTOR(S) COMMENCE FABRICATION AND/OR INSTALLATION ON ANY ITEM LISTED ABOVE PRIOR TO SHOP DRAWING SUBMITTAL AND APPROVAL BY THE ARCHITECT, GENERAL CONTRACTOR SHALL ASSUME ALL RESPONSIBILTY FOR THAT SPECIFIC ITEM (MATERIAL AND LABOR COSTS) AND, SHOULD THE ARCHITECT DETERMINE THAT MODIFICATIONS ARE NECESSARY TO ENABLE THE ITEM OR SYSTEM TO PERFORM TO DESIGN SPECIFICATIONS, THE GENERAL CONTRACTOR SHALL PERFORM OR HAVE PERFORMED THE MODIFICATIONS NECESSARY AT HIS OWN COST. 30. THE GENERAL CONTRACTOR MUST SUBMIT THE FOLLOWING ITEMS TO THE OWNER AND ARCHITECT ALONG WITH FINAL CONSTRUCTION INVOICE PRIOR TO FINAL PAYMENT. GENERAL CONTRACTOR PROVIDES: - GC CERTIFICATION (100% COMPLETE AND 1 YEAR WARRANTY) - CERTIFICATE OF OCCUPANCY - AS-BUILT DRAWINGS - ALL BUILDING INSPECTION SIGN OFF - COPY OF BUILDING PERMIT - CERTIFICATE OF INSURANCE FROM CONTRACTOR - SUBCONTRACTOR LIST - MANUFACTURER'S AND SUBCONTRACTOR'S GUARANTEES AND WARRANTIES - AIR BALANCE REPORT - OWNERS MANUAL OF EQUIPMENT 31. GENERAL CONTRACTOR WILL BE FULLY RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH OBTAINING PERMITS, APPROVALS, IMPACT FEES, TIE-IN FEES, ETC. AS REQUIRED BY ALL APPROVING AGENCIES AND LANDLORDS. 32. GENERAL CONTRACTOR SHALL PREPARE AND SUBMIT TO FIRE DEPARTMENT AND OTHER REQUIRED APPROVING AGENCIES THE FOLLOWING: FIRE ALARM AND SPRINKLER DRAWINGS SIGNED, SEALED AND PREPARED BY A LICENSED ENGINEER FOR REVIEW AND APPROVAL PRIOR TO OBTAINING PERMITS. REFER TO ADDITIONAL NOTES ON SPRINKLER DRAWINGS AND FIRE ALARM DRAWINGS FOR FURTHER CLARIFICATIONS. 33. GENERAL CONTRACTOR TO VERIFY THAT MAXIMUM HEIGHT FOR ALL STAIR RISERS SHALL BE 7" AND MINIMUM STAIR TREAD WIDTH TO BE 11". 34. GENERAL CONTRACTOR/ELECTRICIAN IS RESPONSIBLE FOR PROVIDING TYPED LABELS INDICATING PANEL AND CIRCUIT NUMBER FOR ALL OUTLETS AND JUNCTION BOXES. ADDITIONALLY, THOSE OUTLETS DESIGNATED FOR USE BY THE RED DOT NET MUSIC SYSTEM SHALL BE LABELED WITH RDN/PANEL/CIRCUIT AND AN ADHESIVE RED DOT SHALL BE APPLIED AT BOTH THE OUTLET AND PANEL BREAKER. DRAWING INDEX SHEET TITLE CS TITLESHEET & PROJECT INFORMATION PROJECT DIRECTORY CLIENT: NOK NOK NAIL SALON & HEAD SPA 1660 W HANFORD ARMONA RD, STE C & D, HANFORD, CA 93230 TEL: DESIGNER: MASSIE CONSTRUCTION COMPANY 111 W JACKSON STREET, SUITE 1700, CHICAGO, IL 60604 TEL.: (202) 545-7677 ATTN.: JOE MORALES SEPARATE SUBMITTALS HARMONY CLAUSE THERE SHALL BE NO MANIFESTATIONS ON THE PROJECT OF ANY DISPUTE BETWEEN ANY LABOR ORGANIZATION AND ANY TENANT CONTRACTOR OR SUBCONTRACTOR, INCLUDING BUT NOT LIMITED TO, ANY AREA STANDARDS PICKETING AGAINST SAID CONTRACTOR OR SUBCONTRACTOR. SHOULD THERE BE ANY MANIFESTATION OF A LABOR DISPUTE BETWEEN ANY TENANT CONTRACTOR OR SUBCONTRACTOR AND ANY UNION, WHICH RESULTS IN A STOPPAGE OF WORK ON THE PART OF SAID CONTRACTOR OF CONTRACTOR'S EMPLOYEES OF ANY OTHER EMPLOYER OR SUPPLIER ON THE PROJECT, WHICH IN THE SOLE JUDGMENT OF THE LANDLORD WILL CAUSE, OR IS LIKELY TO CAUSE, UNREASONABLE DELAY IN THE PROGRESS OF CONSTRUCTION THEN UPON WRITTEN NOTICE FROM LANDLORD, THE TENANT SHALL HAVE THE OBLIGATION AND RIGHT TO DECLARE THE CONTRACTOR OR SUBCONTRACTOR IN DEFAULT OF HIS CONTRACT, AND UPON SUCH NOTICE, THE TENANT SHALL HAVE THE RIGHT TO TAKE SUCH STEPS AS NECESSARY TO FINISH THE UNCOMPLETED PORTION OF THE WORK TO BE PERFORMED BY THE CONTRACTOR OR SUBCONTRACTOR. COPYRIGHT NOTICE: MASSIE CONSTRUCTION COMPANY 2024 REPRODUCTION OF MATERIAL AND OR QUOTATIONS SHOWN OR DEPICTED ON PLANS OR IN SPECIFICATIONS WITHOUT PERMISSION OF MASSIE VIOLATES THE COPYRIGHT LAWS OF THE UNITED STATES AND WILL BE SUBJECT TO LEGAL PROSECUTION. ABBREVIATIONS OA OVERALL OC ON CENTER OF OUTSIDE FACE OH OPPOSITE HAND OPNG OPENING OPP OPPOSITE ORIG ORIGINAL PTN PARTITION % PERCENT PERF PERFORATED PERIM PERIMETER PERM PERMANENT PERP PERPENDICULAR PL PLATE PLBG PLUMBING PLUMB PLUMBING +/- PLUS/MINUS PNL PANEL PR PAIR PROJ PROJECT PT PAINT PTD PAINTED PTN PARTITION QTY QUANTITY QUAL QUALITY R RISER RAD RADIUS REC RECESSED REINF REINFORCING REQ'D REQUIRED RET RETURN RD ROOF DRAIN RFG ROOFING RM ROOM RND ROUND RO ROUGH OPENING RWO ROUGH WALL OPENING S SOUTH SB SPLASH BLOCK SDL SADDLE SECT SECTION SIM SIMILAR SLP SLOPE SLV SLEEVE SPEC SPECIFICATION SPKLR SPRINKLER SQ SQUARE SS STAINLESS STEEL STD STANDARD STL STEEL STOR STORAGE STRUCT STRUCTURAL T TREAD TEMP TEMPERED THK THICK TO TOP OF TS TUBE STEEL TYP TYPICAL UNO UNLESS NOTED OTHERWISE VERT VERTICAL VIF VERIFY IN FIELD W WEST WC WATER CLOSET WH WATER HEATER W/ WITH WP WORKING POINT @ AT & AND L ANGLE ACT ACOUSTICAL CEILING TILE ABV ABOVE AFF ABOVE FINISHED FLOOR ADJ ADJUSTABLE AHJ AUTHORITY HAVING JURISDICTION ALUM ALUMINUM APP APPROVED BM BEAM BLDG BUILDING BLK BLOCK BO BOTTOM OF BTM BOTTOM BU BUILT-UP CH CEILING HEIGHT CHK CHECKED CL CENTER LINE CLG CEILING CLJ CONTROL JOINT CLOS CLOSURE CLR CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONST CONSTRUCTION CONT CONTINUOUS CORR CORRIDOR Ø DIAMETER DET DETAIL DIA DIAMETER DIM DIMENSION DISP DISPENSER DN DOWN DR DOOR DTL DETAIL DWG DRAWING E EAST EA EACH EL ELEVATION ELECT ELECTRICAL ENCL ENCLOSURE EQ EQUAL EQUIP EQUIPMENT EWC ELECTRIC WATER COOLER EXIST'G EXISTING EXP EXPANSION EXT EXTERIOR FAST FASTENED FD FLOOR DRAIN FIN FINISH FL FLASHING FLR FLOOR FND FOUNDATION FO FACE OF FTG FOOTING GA GAUGE GEN GENERAL GC GENERAL CONTRACTOR GL GLASS GR GRADE GWB GYPSUM WALL BOARD GYP BD GYPSUM BOARD HM HOLLOW METAL HORIZ HORIZONTAL HP HIGH POINT HR HOUR HT HEIGHT INSUL INSULATION INT INTERIOR INTER INTERMEDIATE JB JUNCTION BOX JT JOINT K KIP (1000 LB) KPL KICK PLATE L LENGTH LDG LANDING LNTL LINTEL LOC LOCATION LP LOW POINT LT LIGHT LVR LOUVER MAS MASONRY MAT MATERIAL MAX MAXIMUM MECH MECHANICAL MEMB MEMBRANE MFR MANUFACTURER MIN MINIMUM MO MASONRY OPENING MR MOISTURE RESISTANT MTD MOUNTED MTG MEETING MTL METAL # NUMBER N NORTH NA NOT APPLICABLE NIC NOT IN CONTRACT NO NUMBER NTS NOT TO SCALE SYMBOLS LEGEND VICINITY/ AERIAL MAP KEY PLAN WALL TYPE CHANGE IN SURFACE HT. WINDOW TAG SYMBOL MATERIAL DOOR TAG W1 101B A KEY NOTE# ROOM 101 ROOM TAG+2'-0" 3 1 2 3 4 A5.6 AX.X X AX.X X AX.X X EXTERIOR ELEVATION INTERIOR ELEVATION SECTION DETAIL CALLOUT REVISION TAG ELEVATION MASONRY INSULATION GYPSUM BOARD PLYWOOD GLASS NEW FRAMED WALL (PLAN) STEEL CONCRETE GRAVEL FILL EARTH BRICK (ELEVATION) BLOCKING UNIT MASONRY CMU (ELEVATION) ROUGH LUMBER ENGINEERED FILL STONE VENEER WOOD SYMBOL SYMBOLMATERIAL MATERIAL REV. 1 REVISIONS AREA OF WORKSITE LOCATION BUILDING CODE DATA AREA BREAK DOWN SPACE NAME GROSS AREA BREAKDOWN COMBINED SQ. FT. ALL CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING CODES AND AMENDMENTS PER THEIR ADOPTING ORDINANCES. 1722 W 1ST STREET, SANTA ANA, CA 92703 JOB ADDRESS: GOVERNING AGENCIES: CODE INFORMATION: PROJECT SCOPE: OVERALL SUMMARY: CITY OF SANTA ANA, CA CONSTRUCTION CODES: MECHANICAL PLUMBING ELECTRICAL BUILDING FIRE ENERGY ACCESSIBILTY BUILDING OFFICIAL: CITY OF SANTA ANA, CA PLANNING & BUILDING AGENCY BUILDING & SAFETY DIVISION 20 CIVIC CENTER PLAZA, SANTA ANA, 92702 TEL: (714) 647-5800 CITY OF SANTA ANA, CA PLANNING & BUILDING AGENCY BUILDING & SAFETY DIVISION 20 CIVIC CENTER PLAZA, SANTA ANA, 92702 2022 CALIFORNIA BUILDING CODE, BUILDING, VOLUMES 1 & 2 2022 CALIFORNIA EXISTING BUILDING CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA ELECTCRICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA GREEN BUILDING CODE 2021 CALIFORNIA BUILDING CODE, CHAPTER 11B AS-100 ARCHITECTURAL SITE PLAN EXISTING PARKING LOT PAINT & RESTRIPING. ROOM # 6-19-2025 DESIGN PROFESSIONAL SEAL STATE ALIF RNI 6-1 -2 2 Bldg #101123960 APPROVALS: PLNG - F. DAlessandro BLDG - G. Huang PUBLIC WORKS - Y. Soto 1 2 3 4 5 6 7 8 9 10 11 12 15 16 17 18 19 20 21 22 2324 25 2728293031 26 34 33 8'-6" 18 ' - 0 " 6'-0"12'-0" 1'-1"1'-1" 9'-0" 18 ' - 0 " 25'-0"25'-0" 7' - 0 " W 1ST STREET PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E PROPERTY LINE 3' - 0 " 6" 3' - 6 " WARNING TACTILE. TRUNCATED DOMES ADA PARKING SIGN w/ TOW AWAY SIGN VAN ADA PARKING SIGN w/ TOW AWAY SIGN 1722 W 1ST STREET ADJACENT PROPERTY BLDG (N.I.C) ADJACENT PROPERTY BLDG (N.I.C) ADJACENT PROPERTY (N.I.C) ADJACENT PROPERTY (N.I.C)ADJACENT PROPERTY (N.I.C) 8' - 0 " 10 ' - 0 " 10 ' - 0 " EX. CONC. WALKEX. CONC. WALK EX. CONC. WALK EX. CONC. WALK EX. LANDSCAPING 32 13 14 UNIT 1 1,700 SF UNIT 2 2,300 SF UNIT 2 3,800 SF ©2024 2025.02.26PROJECT START: REVISION DATE ISSUED: NOTES: SCALE: AS NOTED CHECKED BY:JM DRAWN BY:JM DATE ISSUED: PROJECT NO.:25-0014 2025/02/26 1722 W 1ST STREET, SANTA ANA, CA 92703 PARKING LOT REPAINT PLANS 111 W JACKSON BLVD., STE 1700, CHICAGO, IL 60604 DESIGN PROFESSIONAL SEAL STATE OF CALIFORNIA AS-100 MASSIE CONSTRUCTION COMPANY INC. HEREBY RESERVE IT'S COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHT IN THESE PLANS, IDEAS AND DESIGNS. THESE IDEAS, DESIGNS AND PLANS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THE TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT WRITTEN PERMISSION FROM REFLECT DESIGN + BUILD GROUP, INC. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS OF THE JOB AND MASSIE CONSTRUCTION COMPANY INC. SHALL BE NOTIFIED IN WRITING OF ANY VARIATIONS FROM THE DIMENSION, CONDITIONS AND SPECIFICATIONS SHOWN BY THESE DRAWINGS. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL STATE AND LOCAL CODES. COPYRIGHT NOTICE: MASSIE ©2025 ARCHITECTURAL SITE PLAN SCALE: 1/16 = 1'-0"1 SITE NOTES 1. SITE PLAN IS FOR DESIGN PURPOSES ONLY. REFER TO SIGN AND SEAL SURVEY FOR PROPOSED STRUCTURE LOCATION. 2. DO NOT SCALE DRAWINGS. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ARCHITECTS ATTENTION. 3. CONTRACTOR TO REVIEW DRAWINGS IN ITS ENTIRETY. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ARCHITECTS ATTENTION. 4. OSHA REQUIREMENTS SHALL BE FOLLOWED AT ALL TIMES. CERTIFIED HARD HATS SHALL BE WORN WHILE ON SITE. 5. VERIFY SITE CONDITIONS PRIOR TO COMMENCEMENT OF WORK. 6. VERIFY ALL UTILITY LOCATIONS. MARK WITH IDENTIFIABLE FLUORESCENT PAINT PRIOR TO CONSTRUCTION. 7. DISCONNECT ANY UNNECESSARY SERVICES PRIOR TO CONSTRUCTION. CAP ANY UNUSED SERVICES BELOW GRADE. 8. ALL DEBRIS SHALL BE DISCARDED IN ASSIGNED LOCATION/S IE. DUMPSTER. N ARCHITECTURAL SITE PLAN PARKING DATA EXISTING PROPOSED # OF REGULAR PARKING SPOTS 32 32 # OF HANDICAP PARKING SPOTS 2 2 TOTAL 34 34 FINAL FIXTURES TO BE APPROVED BY OWNER & INTERIOR DESIGNER. ADA FIXTURES TO REMAIN ADA COMPLIANT. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL FIXTURES TO BE ADA COMPLIANT PARKING TABULATION DATA ADDRESS USE SQUARE FOOTAGE PARKING RATIO REQUIRED PARKING UNIT 1 RESTAURANT 1,700 8 SPACES PER 1,000 SF 14 SPACES UNIT 2 BUSINESS 2,300 3 SPACES PER 1,000 SF 7 SPACES UNIT 3 RETAIL 3,800 5 SPACES PER 1,000 SF 19 SPACES TOTAL PARKING SPACES REQUIRED 40 SPACES TOTAL PARKING SPACES PROVIDED 34 SPACES FINAL FIXTURES TO BE APPROVED BY OWNER & INTERIOR DESIGNER. ADA FIXTURES TO REMAIN ADA COMPLIANT. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL FIXTURES TO BE ADA COMPLIANT 6-19-2025 DE I N PR FE I NAL EAL 6-1 -2 2 CITY OF SANTA ANA F1 Itl Plan Submittal Criteria Planning and Buildin -Raw D�r�rn�i�1 01AI COMMERCIAL MULTIFAMILY RESIDENTIAL "'�"V"'""`" ■ projects, proj'eckts FOR PERMIT ISSUANC anu rcwiv�i� i w� � rcrr�, i aevewpmenIs INSTRUCTIONS: rug in ine projean usiness address aria proviae a oner aescnpuon or me scope of worK aria type or busine ss oaera; � 4 Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification c�Aayter ID:'TH If you answer - "YES" to an � FOUNDED y y part of questions 1 through 10, submit the type of plan indicated m italics to bate: In some cases, other plan types not indicated herein may also be necessary depending on specific conditi ns or opers_ • Visit www ocfa orQ for submittal information and locations If you need assistance in filling out this form or lave -qo�� requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602 Aaarass kq q Z W S4r Project Scope/Business Description cv�-S k_.'r � p l,rta R 1C i S V i L of Suite I Cgad$41L 12 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. � Property is adjacent to a wildland area or non -irrigated native vegetation? O� Fire Master Plan (PR / 45); a Fuel Modification Plan may also be required. (PR 120, PR 1 3 J;J'**Located in or < 100'from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300' from an oil/gas seep, or < 1000'from a landfill? Methane Work Plan. (PR170) 5 7 A 'Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hyd rant/sprin kler/stand pipe systems? Underground Plan. (PR470, PR475) O(�'brinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq ft. (> 1,000 ��■� sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ ►s exempt unless classified as an E occupancy by the Building Offician? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story town houseslrowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitohes with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) Installation/modification of locks delaying or preventing occupants from leavin a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) J Joo**'Ol'onstallation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems, compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery, smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion), welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations Special Equipment Plan (PR315, PR340-PR382) (� Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft � maintenance/repair? Cabinetry/woodworking/finishing facility? (."hem Class & floor plan (full urrhiteciiirul plan y' H occupancy); Special Equipment Plans may be necessary. (PR3 1 PR232-PR240) g O Storage or merchandizing areas in excess of 500 sq. ft where items are located higher than 12' (6' for high -hazard commodities, plastic, rubber, foam, etc. )? High -piled StoraQre Plan (PR330) 10 r�j r�A" Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in commercial cooking hood? Hood& Duct E�xfingwshing System, iiut just the hour! mechanicalplan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: ill `Sprinklers/Alarms- Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications system is a licensed innoa 12. A` Fire Hazard Severity Zone' Consult maps available at building department or on OCFA website to determine if your site is located ='s in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. 1 certify under penalty of perjury under the laws of the State of California that the above Is true: Print kA9 Phone Number oz Signature Date 2 BuNing Departmeat: if you have verified that all q1* 1he questions have been answered accurately as ''NO ", and the project does riot otherwise requirg CSC' A review of sprinkler or alarm plants 0. /her, you Islay accept Mis 191ted rornt cis c1 written release that CKTA review is nul required. Should you still require Aat t&P J applicant have plans appruved by 0C'Iv'A, please Milial here- (S or f11tach an ()(Tel referral jortn and have the apph'C(1111 Submit the form along with the approprune plans and fees ,for oC H re vie w. l U-08-14 E E CITY OF SANTA ANA Planning'and Building Agency PAN���W M 0 'ROW W ', C��L�N1Y FIiZI'. AI I II�)Il� I Y�ORPERMITISSUANCE Plan Referral Form Required for OCFA. to review plane upon the mquestof the Building Department & the answers on the Plan Submittal Criteria Forth (onthereveme)ar9s11,'No,,, Gty � County Official Requesting Review: City I County Reference W. -- City I County: Contact %ameft TAle.. Date: E-Ma,1144 Phone #*. NAaster ID- Date: '• Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. " Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County: /+ - -... &.. a"* At • V � d DQ02/"20 rs