HomeMy WebLinkAbout1529 W St Anne Pl Unit #2 - PlanCHECK AND VERIFY ALL DIMENSIONS  BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION  SHALL  CONFORM TO THE C.B.C.  DESIGNER: PROJECT: SA I N T A N N E R E S I D E N C E NE W A D U 15 2 9 W S A I N T A N N E P L . U N I T 2 SA N T A A N A , C A 9 2 7 0 4 PR O J E C T A D D R E S S : MARK DATE REVISION TITLE: JOB NO. 24-410 DRAWN: GH GH CHECKED: DATE: SEP 10 25 SHEET NUMBER OF SHEETS 7-19-25 G-1 SHEET INDEX GENERAL NOTES PROPERTY /OWNER INFO BUILDING DATA LOT COVERAGE GROUND FLR. VICINITY MAP SCOPE OF WORK ARCHITECTURAL DRAWINGS STRUCTURAL DRAWINGS LIST OF CONSULTANTS BUILDING STANDARDS ADMINISTRATIVE CODE SHEET NO.SHEET DESCRIPTION 1. THESE DRAWINGS ARE INTENDED TO CONVEY AN OVERALL DESCRIPTION OF PROJECT IN SUFFICIENT DETAIL FOR ITS COMPLETE CONSTRUCTION. IN SOME CONDITIONS, WHICH ARE COMMONLY ENCOUNTERED IN CONSTRUCTION OF THIS TYPE MAY NOT BE SPECIFICALLY DETAILED IN THESE PLANS. ALL CONDITIONS NOT SPECIFICALLY DETAILED SHALL BE CONSTRUCTED PER THE CURRENT STANDARDS OF APPROPRIATE INDUSTRY AND IN COMPLIANCE WITH THE CURRENTLY ADOPTED CODES, ORDINANCES, REGULATIONS, ETC. 3. NOTHING IN THE DRAWINGS AND/OR SPECIFICATIONS SHALL BE CONSTRUED TO PERMIT AN INSTALLATION THAT COULD BE IN VIOLATION OF THE CURRENTLY ADOPTED CODES. ALL WORK PERFORMED UNDER THIS CONTRACT SHALL BE IN FULL ACCORDANCE WITH THE APPLICABLE ADOPTED CODES, ORDINANCES, REGULATIONS, ETC. 2. THE INTENT OF THESE DRAWINGS AND SPECIFICATIONS IS THAT THE WORK OF THE ALTERATION, REHABILITATION, OR RECONSTRUCTION BE IN ACCORDANCE WITH THE CURRENTLY ADOPTED CODES, ORDINANCES, REGULATIONS, ETC. SHOULD ANY EXISTING CONDITION SUCH AS DETERIORATION OR NONCOMPLIANT CONSTRUCTION BE DISCOVERED WHICH IS NOT COVERED BY THE CONTRACT DOCUMENTS WHEREIN THE FINISHED WORK WILL NOT COMPLY, THE ARCHITECT/ENGINEER SHALL BE NOTIFIED AND A CHANGE ORDER, OR SEPARATE SET OF PLANS, DETAILING AND SPECIFYING THE REQUIRED WORK SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT FOR REVIEW AND APPROVAL. 4. MISPLACEMENT, ADDITION, OR OMISSION OF ANY WORD, LETTER, FIGURE, OR PUNCTUATION MARK, ETC. SHALL IN NO WAY CHANGE OR ALTER THE INTENT, SPIRIT, OR MEANING OF THE DRAWINGS . 5. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD PRIOR TO ORDERING, FABRICATING, OR INSTALLING ANY ASSOCIATED WORK. IF DISCREPANCIES ARE FOUND, THE CONTRACTOR SHALL REQUEST IN WRITING A CLARIFICATION FORM THE ARCHITECT/ ENGINEER PRIOR TO COMMENCEMENT OF ANY ASSOCIATED WORK. 6. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD PRIOR TO ORDERING, FABRICATING, OR INSTALLING ANY ASSOCIATED WORK. IF DISCREPANCIES ARE FOUND, THE CONTRACTOR SHALL REQUEST IN WRITING A CLARIFICATION FORM THE ARCHITECT/ ENGINEER PRIOR TO COMMENCEMENT OF ANY ASSOCIATED WORK. 7. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THE ARCHITECT/ENGINEER MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN ON THESE DRAWINGS. 8. CUTTING, NOTCHING, OR BORING THROUGH NEW OR EXISTING STRUCTURAL ELEMENTS TO BE DONE ONLY WHEN SO DETAILED IN THE DRAWINGS. 9. THE CONTRACTOR SHALL VERIFY, AT THE SITE, ALL EXISTI NG CONDITIONS PRIOR TO SUBMITTAL OF BIDS. 10. THE CONTRACTOR(S) SHALL BE RESPONSIBLE FOR THEIR OWN CLEANUP AS WORK PROGRESSES. 11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL WORK PROVIDED BY OTHERS UNDER SEPARATE CONTRACT. 12. THE CONTRACTOR SHALL INSTALL WALL BACKINGS, BLOCKING, OR MISCELLANEOUS STEEL AS REQUIRED FOR ALL PARTITIONS, LIGHT FIXTURES, FIXED SHELVES, AND ACCESSORIES. 13. THE CONTRACTOR SHALL INSTALL BRACING AND TEMPORARY SUPPORTS AS REQUIRED TO HOLD THE WORK SECURELY IN PLACE AND SUSTAIN ALL LOADS THAT MAY OCCUR DURING ERECTION. 14. DETAILS OR SECTIONS NOTED AS "TYP" (TYPICAL) OR "SIM" (SIMILAR) SHALL APPLY IN ALL CASES WHETHER OR NOT SPECIFICALLY REFERENCED. 15. WHERE INSTALLATIONS INCLUDE MANUFACTURED PRODUCTS, COMPLY WITH MANUFACTURER'S APPLICABLE INSTRUCTIONS AND RECOMMENDATIONS FOR INSTALLATION. 16. ALL ELECTRICAL AND PLUMBING SHALL CONFORM WITH THE LATEST ADOPTED CODE AND ALL OTHER APPLICABLE CODE REGULATIONS AS REQUIRED BY THE CITY OR COUNTY. 17. ANY REQUIRED INTERRUPTION OF OR REMOVAL OF ANY UTILITY SERVICE SERVING THE EXISTING DWELLING SHALL NOT BE PERFORMED UNTIL A MINIMUM OF A 24 -HOUR PRIOR NOTICE IS GIVEN TO THE OWNER BY THE CONTRACTOR. SUCH WORK SHALL BE COORDINATED WITH THE OWNER AND THE APPLICABLE UTILITY COMPANY. AS MAY BE NECESSARY. THE REMOVAL OR RELOCATING OF ANY EXISTING OR NEW UTILITY(S) (SEWER, PLUMBING, PHONE LINES, GAS LINE, ETC.) SHALL BE DONE BY THE CONTRACTOR AT NO EXTRA COST TO THE OWNER. 18. ALL WORK SHALL BE PERFORMED IN A WORK MAN LIKE MANNER, USING ACCEPTED TRADE PRACTICES AND NEW MATERIALS FREE FROM ALL DEFECTS. 19. CONTRACTOR SHALL PROTECT ALL EXISTING WORK. ANY DAMAGED WORK SHALL BE REPLACED WITH THE SAME MATERIALS, INCLUDING MATCHING THE EXISTING COLORS & TEXTURES. 20. EXISTING WORK IS SHOWN FOR REFERENCE ONLY. THE OWNER & ARCHITECT/ENGINEER DO NOT GUARANTEE EXISTING CONDITIONS AS SHOWN ON THESE DOCUMENTS. DESIGNER STRUCTURAL ENGINEER TITLE 24 ANALYSIS GUADALUPE HERNANDEZ 714 725 8320 CONTACT@CASTILLOENGINEERING.COM 714 631 2458 C8202964@YAHOO.COM MARGARITO CASTILLO 1147 E Market St, Long Beach, CA 90805 805 904 9048 TITLE24@YAHOO.COM TIMOTHY CARSTAIRS 2238 BAYVIEW HEIGHTS DRIVE, SUITE E LOS OSOS, CA 93402 DEVELOPMENT FEE A.D.U. 1529 W SAINT ANNE PL. UNIT 2 SANTA ANA CA 92704 ASSESSOR ID: 408-342-09 PROPERTY TYPE: SINGLE FAMILY-RESIDENTIAL LEGAL DESCRIPTION: N-TRACK:2208 BLOCK: LOT:104 BEDROOMS / BATHROOMS: 3 / 2 UNITS: 1 ZONING: R-1N FEMA DESIGNATED FLOOD ZONE: X OCCUPANCY GROUP: R3/U TYPE OF CONSTRUCTION: VB FIRE SEVERITY HAZARD ZONE: NO ADDRESS: 1529 SAINT ANNE PL. UNIT 2 SANTA ANA, CA 92704 LOT SIZE: 65.00 FT. X 105.00 FT. LOT AREA: 6,775.00 SQ.FT. (E) DWELLING: 1,304.00 SQ.FT. (E) GARAGE: 400.00 SQ.FT. (N) A.D.U. 784.00 SQ.FT. (N) A.D.U. PORCH 28.00 SQ.FT. TOTAL: 2,513.0 SQ.FT. TOTAL RFA: 2 085.00 SQ.FT. NEW 784.00 SQ.FT. A.D.U. ATTACHED TO EXISTING FAMILY DWELLING. 2 085.00 / 6,775.00 SQ.FT. = 0.30 FAR FAR: 30% OPEN SPACE 6,775.00 -2 085.00 = 4 690.00 SQ.FT. SITE PLAN A1.0 TITLE SHEET G-1 DEMO PLAN A2.0 FLOOR PLAN A2.2 EXISTING ELEVATIONS A3.0 ELEVATIONS A3.2 ROOF PLAN A4.0 TITLE SHEET STRUCTURAL NOTES S1.0 1529 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA ENERGY CODE (CEEC) 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA HISTORICAL BUILDING CODE 2022 CALIFORNIA EXISTING BUILDING CODE 2022 CALIFORNIA GREN BUILDING STANDARDS CODE (CAL GREEN) SANTA ANA MUNICIPAL CODE TYPICAL DETAILS S1.1 TYPICAL DETAILS S1.2 TYPICAL DETAILS S1.3 FOUNDATION PLAN S2.0 ROOF FRAMING PLAN S2.2 FOUNDATION DETAILS S3.0 ROOF FRAMING DETAILS S5.0 SECTIONS A4.1 TITLE 24 T-1 RES. MANDATORY REQ. SUMMARY T-2 FRONT WALL 3D A2.3 CAL GREEN SHEETS T-3 T-4 CAL GREEN SHEETS NEW SITE PLAN A1.1 SFR: 784 SF/1322 SF = 0.593 The ADU sf / SFD sf ratio is for Park & Rec fee purpose only. The applicant is responsible for the given “SFR sf” of the existing primary residence; Building Safety staff are notresponsible for the accuracy of the given “SFR sf”of the existing residence. Bldg #'s 101123772 & 25165 APPROVALS: PLNG - C. Santana BLDG - CSG POLICE - B. Martin PUBLIC WORKS - B. Sarlak LI C E N S E N O . E X P . D A T E AR C H I T E C T : OR A N G E C O U N T Y F I R E A U T H O R I T Y CO M M U N I T Y R I S K R E D U C T I O N - P L A N N I N G A N D D E V E L O P M E N T S E C T I O N CH E C K E D : DA T E : SC A L E : 4 3 2 1 NO . DA T E DE S I G N E D : DR A W N : 7 6 5 SHEET SERVICE REQUEST NUMBER 1 RESIDENTIAL SITE PLAN ORANGE COUNTY FIRE AUTHORITY VICINITY MAP OCFA STAMP <INSERT LOCATION MAP THAT INCLUDES MAJOR CROSS STREETS PROVIDING SITE ACCESS> O C F A R E V I E W A N D I N S P E C T I O N S ( O C F A U S E O N L Y ) NO O C F A R E V I E W R E Q U I R E D PL A N R E V I E W O N L Y PL A N R E V I E W A N D I N S P E C T I O N OCFA STANDARD RESIDENTIAL SITE PLAN NOTES RE V I S E D 6 / 2 / 2 0 2 0 J A H INSTRUCTIONS FOR APPLICANT 1. FILL IN ALL APPLICABLE INFORMATION BELOW 2.FILL IN ALL APPLICABLE BUBBLES 3.ADD LOCATION MAP SHOWING NEAREST CROSS STREETS PROVIDING FIRE DEPARTMENT ACCESS. 4. ARCHITECTURAL SUBMITTALS TO OCFA REQUIRE COMPLETE ARCHITECTURAL SHEETS INCLUDING EGRESS ANALYSIS AND DOOR SCHEDULE AS WELL ELECTRICAL SHEETS TO BE SUBMITTED FOR REVIEW. ORANGE COUNTY FIRE AUTHORITY Reviewed by Planning & Development Service Request Expires After 6 Months of Inactivity Approval subject to field inspection and required test, notations hereon, conditions in correspondence and conformance with applicable regulations. The stamping of these plans shall not be held to permit or approve the violation of any law. OCFA SR #: Fee Codes: Plan Type: By: ONLY STAMPED SHEETS REVIEWED BY ORANGE COUNTY FIRE AUTHORITY Call at least 72 hours in advance to schedule inspections: (714) 573­6150 Notes: 25001344 PR160 OCFA Approved PR 160 Residential Site Plan Date: 04/30/2025 brianslegers AUT H O RITY FI RE REVIEWED CALIFORNIA ROANGE COUNTY 25001344 PR160 OCFA Approved LI C E N S E N O . E X P . D A T E AR C H I T E C T : OR A N G E C O U N T Y F I R E A U T H O R I T Y CO M M U N I T Y R I S K R E D U C T I O N - P L A N N I N G A N D D E V E L O P M E N T S E C T I O N CH E C K E D : DA T E : SC A L E : 4 3 2 1 NO . DA T E DE S I G N E D : DR A W N : 7 6 5 SHEET SERVICE REQUEST NUMBER 1 RESIDENTIAL SITE PLAN ORANGE COUNTY FIRE AUTHORITY VICINITY MAP OCFA STAMP <INSERT LOCATION MAP THAT INCLUDES MAJOR CROSS STREETS PROVIDING SITE ACCESS> O C F A R E V I E W A N D I N S P E C T I O N S ( O C F A U S E O N L Y ) NO O C F A R E V I E W R E Q U I R E D PL A N R E V I E W O N L Y PL A N R E V I E W A N D I N S P E C T I O N OCFA STANDARD RESIDENTIAL SITE PLAN NOTES RE V I S E D 6 / 2 / 2 0 2 0 J A H INSTRUCTIONS FOR APPLICANT 1. FILL IN ALL APPLICABLE INFORMATION BELOW 2.FILL IN ALL APPLICABLE BUBBLES 3.ADD LOCATION MAP SHOWING NEAREST CROSS STREETS PROVIDING FIRE DEPARTMENT ACCESS. 4. ARCHITECTURAL SUBMITTALS TO OCFA REQUIRE COMPLETE ARCHITECTURAL SHEETS INCLUDING EGRESS ANALYSIS AND DOOR SCHEDULE AS WELL ELECTRICAL SHEETS TO BE SUBMITTED FOR REVIEW. ORANGE COUNTY FIRE AUTHORITY Reviewed by Planning & Development Service Request Expires After 6 Months of Inactivity Approval subject to field inspection and required test, notations hereon, conditions in correspondence and conformance with applicable regulations. The stamping of these plans shall not be held to permit or approve the violation of any law. OCFA SR #: Fee Codes: Plan Type: By: ONLY STAMPED SHEETS REVIEWED BY ORANGE COUNTY FIRE AUTHORITY Call at least 72 hours in advance to schedule inspections: (714) 573­6150 Notes: 25001344 PR160 OCFA Approved PR 160 Residential Site Plan Date: 04/30/2025 brianslegers AUT H O RITY FI RE REVIEWED CALIFORNIA ROANGE COUNTY 25001344 PR160 OCFA Approved (E) SINGLE FAMILY DWELLING 1,304.00 SQ.FT. 1529 W SAINT ANNE PL. (E) GARAGE 400.00 SQ.FT. (E) LANDSCAPE (E ) C O N C R E T E (E) DRIVEWAY APPROACH (E) LANDSCAPE 105.00 FT. 65 . 0 0 F T . S. S P R U C E S T . (E) CONCRETE DRIVEWAY (E) CONCRETE (E) LANDSCAPE (E) G-M(E) E-M PL (E) WOODEN WALL 6' HEIGHT (E) CMU WALL 6' HEIGHT (E ) C M U W A L L 6 ' H E I G H T 65 . 0 0 F T . 105.00 FT. PL PL PL PL PL PL PL (E ) L A N D S C A P E ( E ) L A N D S C A P E (E ) S I D E W A L K (E) W-H NEW A.D.U. 783.66 SQ.FT. 1529 W SAINT ANNE PL UNIT 2 2% 2%2% 2% 2%2% 15 R 6' - 0" 4' - 4 " 4' - 4 " 25 ' - 1 0 " 25' - 4" 10 ' - 2 " 35' - 2" 2% 1529 W SAINT ANNE PL (E) LANDSCAPE (E) LANDSCAPE (N) Homeline 100 Amp 16-Space 24-Circuit Outdoor Ring-Type Overhead/Underground Surface Mount Main Breaker CSED or similar MINISPLIT OUTSIDE UNIT. Enclosed Tankless W-H WOODEN WALL 2'-6" HEIGHT No shared utilities (N) G-M HEDGES MAY NOT BE HIGHER THAN 2.5' WITHIN CORNER LINE OF SIGHT TRIANGLE. HEDGES MAY NOT BE HIGHER THAN 3' OUTSIDE CORNER AREA. ENCLOSED WATER HEATER ENCLOSEMENT APPROVED BY CITY ON 2022 CONCRETE -AN EASEMENT AFFECTS THE REAR SIX (6) FEET. FOR: INSTALLATION AND MAINTENENCE OF UTILITIES AND DRAINAJE FACILITIES AND INCIDENTAL PURPOSES. -AN EASEMENT AFFECTS: THE LOCATION OF SAID EASEMENT IS SET FORTH THEREIN. FOR: CONSTRUCT, PLACE, OPERATE, INSPECT, MAINTAIN, REPAIR, REPLACE, AND REMOVE SUCH AERIAL AND UNDERGROUND TELEPHONE, TELEGRAPH AND COMMUNICATION STRUCTURES AS GRANTEE MAY FROM TIME TO TIME REQUIRE, CONSISTING OF POLES, ANCHORS, WIRES, CABLES, CONDUITS, MANHOLES, MARKERS, AND NECESSARY FIXTURES AND APPURTENANCES AND INCIDENTAL PURPOSES. -AN EASEMENT AFFECTS THE WEST 6 FEET OF SAID LAND. CONSTRUCT, USE, MAINTAIN, OPERATE, ALTER, ADD TO, REPAIR, REPLACE, AND/OR REMOVE, ELECTRIC LINE, CONSISTING OF POLES, NECESSARY GUYS AND ANCHORS, CROSS-ARMS, WIRES AND OTHER FIXTURES AND APPLIANCES, FOR CONVEYING ELECTRIC ENERGY TO BE USED FOR LIGHT, HEAT, POWER, TELEPHONE AND/OR OTHER PURPOSES AND INCIDENTAL PURPOSES. 6' - 0 " 22 SQ.FT. PORCH (E) UTILITY POLE SCALE: 3/16" = 1'-0"1 SITE PLAN CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. DESIGNER: PROJECT: SA I N T A N N E R E S I D E N C E A. D . U . 15 2 9 W S A I N T A N N E P L . U N I T 2 SA N T A A N A , C A 9 2 7 0 4 PR O J E C T A D D R E S S : MARK DATE REVISION TITLE: SHEET NUMBER OF SHEETS JOB NO. 24-410 DRAWN: GH CHEKED: GH DATE: FEB 12 25 7-19-25 A1.0N SITE PLAN (E) SINGLE FAMILY DWELLING 1,304.00 SQ.FT. 1529 W SAINT ANNE PL. (E) GARAGE 400.00 SQ.FT. (E) LANDSCAPE (E ) C O N C R E T E (E) DRIVEWAY APPROACH (E) LANDSCAPE 105.00 FT. 65 . 0 0 F T . S. S P R U C E S T . (E) CONCRETE DRIVEWAY (E) CONCRETE (E) LANDSCAPE (E) G-M (E) E-M PL (E) WOODEN WALL 6' HEIGHT (E) CMU WALL 6' HEIGHT (E ) C M U W A L L 6 ' H E I G H T 65 . 0 0 F T . 105.00 FT. PL PL PL PL PL PL PL (E ) L A N D S C A P E ( E ) L A N D S C A P E (E ) S I D E W A L K (E) W-H NEW A.D.U. 783.66 SQ.FT. 1529 W SAINT ANNE PL UNIT 2 2% 2%2% 2% 2% 2% 15 R 4' - 4 " 25 ' - 1 0 " 25' - 4" 10 ' - 2 " 35' - 2" 2% 1529 W SAINT ANNE PL (E) LANDSCAPE (E) LANDSCAPE (N) Homeline 100 Amp 16-Space 24-Circuit Outdoor Ring-Type Overhead/Underground Surface Mount Main Breaker CSED or similar MINISPLIT OUTSIDE UNIT. Enclosed Tankless W-H WOODEN WALL 2'-6" HEIGHT No shared utilities (N) G-M HEDGES MAY NOT BE HIGHER THAN 2.5' WITHIN CORNER LINE OF SIGHT TRIANGLE. HEDGES MAY NOT BE HIGHER THAN 3' OUTSIDE CORNER AREA. ENCLOSED WATER HEATER ENCLOSEMENT APPROVED BY CITY ON 2022 CONCRETE WATER LINE 6' - 0 " 22 SQ.FT. PORCH W SEWER LINE S ELECTRICITY LINE E GAS LINE G S S S S S S S S S S S S S S S S G G G G G G G G G G G G G G W W W W W W W W W S W W W W W W W W W W W W W W W W W W W W W W W W W W W 4" 3' - 8" 2' - 0 " 2' - 4" 2' - 4 " 1 HR RATED (E) UTILITY POLE E E E E E 4" 1 HR RATED EAVE SEE DETAIL 4 IN A2.2 CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. DESIGNER: PROJECT: SA I N T A N N E R E S I D E N C E A. D . U . 15 2 9 W S A I N T A N N E P L . U N I T 2 SA N T A A N A , C A 9 2 7 0 4 PR O J E C T A D D R E S S : MARK DATE REVISION TITLE: SHEET NUMBER OF SHEETS JOB NO. 24-410 DRAWN: GH CHEKED: GH DATE: FEB 12 25 7-19-25 A1.1 SCALE: 3/16" = 1'-0"1 NEW SITE PLAN NEW SITE PLAN (E ) B A T H R O O M (E) LIVING AREA (E ) D I N I N G A R E A (E) KITCHEN (E) BEDROOM (E) BEDROOM (E) OFFICE (E) W-H 2 (E ) B A T H R O O M (E) BEDROOM 2 NOTES FOR NEW ENERGY CODE REQUIREMENTS a) Energy storage systems (ESS) ready. All single-family residences that include one or two dwelling units shall meet the following. All electrical components shall be installed in accordance with the California Electrical Code: 1. At least one of the following shall be provided: A. ESS ready interconnection equipment with a minimum backed-up capacity of 60 amps and a minimum of four ESS-supplied branch circuits, or B. A dedicated raceway from the main service to a panelboard (subpanel) that supplies the branch circuits in Section 150.0(s)(2). All branch circuits are permitted to be supplied by the main service panel prior to the installation of an ESS. The trade size of the raceway shall be not less than 1 inch. The panelboard that supplies the branch circuits (subpanel) must be labeled "Subpanel shall include all backed-up load circuits." 2. A minimum of four branch circuits shall be identified and have their source of supply collocated at a single panelboard suitable to be supplied by the ESS. At least one circuit shall supply the refrigerator, one lighting circuit shall be located near the primary egress and at least one circuit shall supply a sleeping room receptacle outlet. 3. The main panelboard shall have a minimum busbar rating of 225 amps. 4. Sufficient space shall be reserved to allow future installation of a system isolation equipment/transfer switch within 3 feet of the main panelboard. Raceways shall be installed between the panelboard and the system isolation equipment/transfer switch location to allow the connection of backup power source. b) Heat pump space heater ready. Systems using gas or propane furnace to serve individual dwelling units shall include the following: 1. A dedicated 240 volt branch circuit wiring shall be installed within 3 feet from the furnace and accessible to the furnace with no obstructions. The branch circuit conductors shall be rated at 30 amps minimum. The blank cover shall be identified as "240V ready." All electrical components shall be installed in accordance with the California Electrical Code. 2. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a future heat pump space heater installation. The reserved space shall be permanently marked as "For Future 240V use." c) Electric cooktop ready.Systems using gas or propane cooktop to serve individual dwelling units shall include the following: 1. A dedicated 240 volt branch circuit wiring shall be installed within 3 feet from the cooktop and accessible to the cooktop with no obstructions. The branch circuit conductors shall be rated at 50 amps minimum. The blank cover shall be identified as "240V ready." All electrical components shall be installed in accordance with the California Electrical Code. 2. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a future electric cooktop installation. The reserved space shall be permanently marked as "For Future 240V use." d) Electric clothes dryer ready.Clothes dryer locations with gas or propane plumbing to serve individual dwelling units shall include the following: 1. A dedicated 240 volt branch circuit wiring shall be installed within 3 feet from the clothes dryer location and accessible to the clothes dryer location with no obstructions. The branch circuit conductors shall be rated at 30 amps minimum. The blank cover shall be identified as "240V ready. " All electrical components shall be installed in accordance with the California Electrical Code. 2. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a future electric clothes dryer installation. The reserved space shall be permanently marked as "For Future 240V use." CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. DESIGNER: PROJECT: SA I N T A N N E R E S I D E N C E A. D . U . 15 2 9 W S A I N T A N N E P L . U N I T 2 SA N T A A N A , C A 9 2 7 0 4 PR O J E C T A D D R E S S : MARK DATE REVISION TITLE: SHEET NUMBER OF SHEETS JOB NO. 24-410 DRAWN: GH CHEKED: GH DATE: FEB 12 25 7-19-25 A2.0 REMOVE EXISTING DOOR AND FILL OUT THE OPENING ------------ LEGEND KEYNOTESKEYNOTES NEW WALL EXISTING WALL DEMO WALL THE KEY NOTES DIRECTLY BELOW REFER THE DEMO PLAN ONLY 1 2 3 4 5 6 7 8 9 10 12 11 13 14 15 16 17 18 19 20 DEMO PLAN SCALE: 1/4" = 1'-0"1 DEMO PLAN ------ ------- -------- 3 3 3 3 GF C I GF C I GFCI GF C I AF C I AF C I AF C I AF C I AFCI AF C I AF C I AF C I AF C I AFCI AFCI AFCIAFCI AF C I AF C I AFCI AFCI AFCI AF C I AF C I GF C I GFCI GFCI GFCI GF C I AFCI AFCI AF C I AF C I GF C I GF C I GFCI GFCI AF C I AFCI AF C I AF C I 3 3 AF C I AF C I AF C I GF C I GF C I GF C I GFCI GFCI GF C I (E) LIVING AREA 328 SF. (E ) D I N I N G A R E A (E) KITCHEN (E) BEDROOM BEDROOM (E) GARAGE (E) BEDROOM (E) MASTER BEDROOM SD CO SD CO SD SD SD SD 7 3/4" MAX THRESHOLD 23' - 6" 31 ' - 2 " 10' - 2"2' - 6"10' - 10" SD SD CO (E ) B A T H R O O M (E ) B A T H R O O M LA U N D R Y BEDROOM KITCHEN LIVING AREA A A A B C A1 4 3 3 1 A4.1 2 A4.1 85% CE OR 280 CFM KITCHEN RANGE HOOD WP WP 2 2 BA T H R O O M B 13 ' - 3 " 5' - 6 " 12 ' - 5 " 17 ' - 2 " 19' - 2" 2' - 2 " (E) WH 4' - 1 " 5' - 3" 3' - 0" 3' - 0"3' - 0" 1' - 5"1' - 5" 8' - 5" 8' - 7 " D 11' - 0" 29' - 2" LANDING D D D D D D D D ø 2' - 6" 2' - 2 " VS VS 1' - 10" 2' - 6 " AT T I C AC C E S S BREAKFAST TABLE TOP 3' - 0" 5' - 0 " 4' - 0"3' - 6"2' - 9"2' - 6"5' - 6" 3' - 0 " Future Installation of a Heat Pump Water Heater 458X.08=36.64 SF OF GLAZING AREA NEW 4'X4' WINDOW D= 16 SF (E) 60"X48" WINDOW E (E) 5'X4' WINDOW E = 20 SF (E) 3'X6'-8" ENTRY HALF ARCH DOOR (E) HALF ARCH DOOR 2.33'X3.33' = 7.76 SF TOTAL = 43.76 SF R327.1.1 Reinforcement for Grab Bars At least one bathroom on the entry level shall be provided with reinforcement installed in accordance with this section. Where there is no bathroom on the entry level, at least one bathroom on the second or third floor of the dwelling shall comply with this section. Reinforcement shall be solid lumber or other construction materials approved by the enforcing agency. Reinforcement shall not be less than 2 by 8 inch (51 mm by 203 mm) nominal lumber. [11/2 inch by 71/4 inch (38 mm by 184 mm) actual dimension] or other construction material providing equal height and load capacity. Reinforcement shall be located between 32 inches (812.8 mm) and 391/4 inches (997 mm) above the finished floor flush with the wall framing. Water closet reinforcement shall be installed on both side walls of the fixture, or one side wall and the back wall. Shower reinforcement shall be continuous where wall framing is provided. Bathtub and combination bathtub/shower reinforcement shall be continuous on each end of the bathtub and the back wall. Additionally, back wall reinforcement for a lower grab bar shall be provided with the bottom edge located no more than 6 inches (152.4 mm) above the bathtub rim. R327.1.2 Electrical Receptacle Outlet, Switch and Control Heights Electrical receptacle outlets, switches and controls (including controls for heating, ventilation and air conditioning) intended to be used by occupants shall be located no more than 48 inches (1219.2 mm) measured from the top of the outlet box and not less than 15 inches (381 mm) measured from the bottom of the outlet box above the finish floor. R327.1.3 Interior Doors Effective July 1, 2024, at least one bathroom and one bedroom on the entry level shall provide a doorway with a net clear opening of not less than 32 inches (812.8 mm), measured with the door positioned at an angle of 90 degrees from the closed position; or, in the case of a two-or three-story single family dwelling, on the second or third floor of the dwelling if a bathroom or bedroom is not located on the entry level. 2 1 HR FIRE AND SOUND RATED WILL GO FROM THE FOUNDATION TO THE BOTTOM OF THE ROOF SHEATHING. SEE DETAIL 2 IN A2.2 R327.1.4 Doorbell Buttons Doorbell buttons or controls, when installed, shall not exceed 48 inches (1219.2 mm) above exterior floor or landing, measured from the top of the doorbell button assembly. Where doorbell buttons integrated with other features are required to be installed above 48 inches (1219.2 mm) measured from the exterior floor or landing, a standard doorbell button or control shall also be provided at a height not exceeding 48 inches (1219.2 mm) above exterior floor or landing, measured from the top of the doorbell button or control. (n) WATER HEATING SYSTEM. 1. Systems using gas or propane water heaters to serve individual dwelling units shall designate a space at least 2.5 feet by 2.5 feet wide and 7 feet tall suitable for the future installation of a heat pump water heater (HPWH) by meeting either A or B below. All electrical components shall be installed in accordance with the California Electrical Code: A. If the designated space is within 3 feet from the water heater, then this space shall include the following: i. A dedicated 125 volt, 20 amp electrical receptacle that is connected to the electric panel with a 120/240 volt 3 conductor, 10 AWG copper branch circuit, within 3 feet from the water heater and accessible to the water heater with no obstructions; and ii. Both ends of the unused conductor shall be labeled with the word “spare”and be electrically isolated; and iii. A reserved single pole circuit breaker space in the electrical panel adjacent to the circuit breaker for the branch circuit in A above and labeled with the words “Future 240V Use”; and iv. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance. B. If the designated space is more than 3 feet from the water heater, then this space shall include the following: i. A dedicated 240 volt branch circuit shall be installed within 3 feet from the designated space. The branch circuit shall be rated at 30 amps minimum. The blank cover shall be identified as “240V ready”; and ii. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a future HPWH installation. The reserved space shall be permanently marked as “For Future 240V use”; and iii. Either a dedicated cold water supply, or the cold water supply shall pass through the designated HPWH location just before reaching the gas or propane water heater; and iv. The hot water supply pipe coming out of the gas or propane water heater shall be routed first through the designated HPWH location before serving any fixtures; and v. The hot and cold water piping at the designated HPWH location shall be exposed and readily accessible for future installation of an HPWH; and vi. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance. 2. Water heating recirculation loops serving multiple dwelling units shall meet the requirements of Section 110.3(c)4. 3. Solar water-heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC), the International Association of Plumbing and Mechanical Officials, Research and Testing (IAPMO R&T), or by a listing agency that is approved by the Executive Director. 4. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2kW) shall meet the requirements of Section 110.3(c)6. SEE DETAILS OF: AGING-IN-PLACE IN A4.0 ROOF PLAN CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. DESIGNER: PROJECT: SA I N T A N N E R E S I D E N C E A. D . U . 15 2 9 W S A I N T A N N E P L . U N I T 2 SA N T A A N A , C A 9 2 7 0 4 PR O J E C T A D D R E S S : MARK DATE REVISION TITLE: SHEET NUMBER OF SHEETS JOB NO. 24-410 DRAWN: GH CHEKED: GH DATE: FEB 12 25 7-19-25 A2.2 KEYNOTES THE KEY NOTES DIRECTLY BELOW REFER THE FLOOR PLAN ONLY 1 2 3 4 5 6 7 8 LEGEND PLAN NOTES NEW WALL EXISTING WALL DEMO WALL SD CO SURFACE OR PENDANT MTD. LT. FIXTURE (HIGH EFFICACY) SINGLE POLE SWITCH SMOKE DETECTOR 110VOLT, WITH BATTERY BACK UP ALL SMOKE DETECTORS SHALL BE INTERCONNECTED CARBON MONOXIDE DETECTOR 110 VOLT, WITH BATTERY BACK UP WALL MTD. LT. FIXTURE (HIGH EFFICACY) THREE WAY POLE SWITCH WALL OUTLET 110 VOLTS ALL OUTLETS SHALL BE TAMPERED RESISTANT TYP. 50 CFM TO EXHAUST MOISTURE OF THE BUILDING MECHANICAL VENTILATION REQUIRED IN ALL BATHROOM WITH TUB OR SHOWER FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO DETERMINATE TO THE OUTSIDE OF THE BUILDING. FANS, NOT FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, MUST BE CONTROLLED BY A HUMIDITY CONTROL. EXISTING WINDOW TYPE PER SCHEDULE THIS SHEET DOOR TYPE PER SCHEDULE THIS SHEET NOTE PER KEYNOTES (E) A 6 29 3 DOUBLE POLE SWITCH2 FIRE WALL THREE WAY POLE SWITCH WITH DIMMER3D SWITCH WITH VACANCY SENSORVS 1. PROVIDE ATTIC ACCESS OPENING (22"x30" MIN.) READILY ACCESSIBLE WITH A 30" MIN. CLEAR HEAD ROOM ABOVE ACCESS IN ALL ATTIC SPACES WITH A MINIMUM VERTICAL HEIGHT OF 30". 2. ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLTS, SINGLE PHASE, 15 & 20 AMPERE RECEPTACLE OUTLETS INSTALLED IN BEDROOMS SHALL BE PROTECTED BY AN ARC-FAULTED CIRCUIT INTERRUPTERS. 3. ACCES PANEL 12"x12" REQUIRED FOR TUB TRAP SLIP-JOINT OR USE NON-SLIP (WELDED) JOINTS. 4. PROVIDE MECHANICAL VENTILATION CAPABLE OF PROVIDING FIVE AIR CHANGES PER HOUR IN BATHROOMS. DUCTLESS FANS ARE NOT ACCEPTABLE. THE POINT OF DISCHARGE SHALL BE AT LEAST 3 FEET FROM ANY OPENING. 5. WATER CLOSETS (TOILETS) SHALL BE CERTIFIED TO USE A MAXIMUM OF 1.28 GALLONS PER FLUSH. 6. SHOWER SHALL HAVE EITHER A PRESSURE VALVE BALANCE OR A THERMOSTATIC MIXING VALVE. SHOWER HEADS SHALL BE CERTIFIED TO USE A MAXIMUM OF 1.8 GALLONS PER MINUTE. 7. SMOKE DETECTORS SHALL RECEIVE THEIR PRIMARY POWER SOURCE FROM THE BUILDING WIRING AND SHALL BE EQUIPPED WITH A BATTERY BACK-UP AND ALLOW BATTERY SIGNAL. IN EXISTING CONSTRUCTION SMOKE DETECTORS MAY BE BATTERY OPERATED. 8. IN A CLOSET, SURFACE MOUNTED LIGHTING FIXTURES SHALL BE AT LEAST 18 INCHES FROM A STORAGE AREA AND FLUSH MOUNTED LIGHTING FIXTURES SHALL BE AT LEAST 6 INCHES FROM A STORAGE AREA. 9. GROUND-FAULT CIRCUIT-INTERRUPTER. (GFCI) PROTECTED ELECTRICAL RECEPTACLES SHALL BE PROVIDED AT: • ALL RECEPTACLES INSTALLED IN A BATHROOM. • ALL RCEPTACLES INSTALLED IN A GARAGE. • ALL OUTDOOR RECEPTACLES WHERE THERE IS DIRECT GRADE LEVEL ACCESS. 10. BATHROOM RECEPTACLES SHALL BE SERVED BY DEDICATED 20 AMP.CIRCUIT. 11. SHOWER WALLS SHALL BE FINISHED WITH A SMOOTH HARD, NON-ABSORBENT SURFACE SUCH AS PORTLAND CEMENT TILE OR OTHER APPROVED MATERIAL. SUCH WALL FINISH SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 72 IN. ABOVE THE DRAIN INLET. 12. LAZING IN DOORS AND WINDOWS SHALL BE PROVIDED WITH TEMPERED GLASS AS REQUIRED IN U.B.C. CHAPTER 24 INCLUDING GLAZING IN ANY PORTION OF A BUILDING WALL AND GLAZING IN ANY PORTION OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF TH GLAZING IS LESS THAN 60 INCHES ABOVE A STANDING SURFACE AND DRAIN INLET; GLAZING IN FIXED OR OPENABLE PANELS ADJACENT TO A DOOR WHERE THE NEAREST EXPOSED EDGE TO THE GLAZING IS WITHIN A 24-INCH ARC OF EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES ABOVE THE WALKING SURFACE. GLAZING IN WALLS ENCLOSING STAIRWAYS LANDINGS OR WITHING 5 FEET OF THE BOTTOM AND TOP OF STAIRWAYS WHERE THE BOTTOM EDGE OF THE GLASS IS LESS THAN 60 INCHES ABOVE FLOOR PLAN SCALE: 1/4" = 1'-0"1 FLOOR PLAN SEE NOTES ON A4.0 WINDOW SHEDULE MARK SIZE WIDTHxHEIGHT QUANTITY REMARKS A 5'-0" x 4'-0" 4 SLIDING DOUBLE WINDOW TEMPERED VINYL B 2'-0" x 1'-4" 2 SLIDING DOUBLE WINDOW DUAL GLAZE VINYL C DOOR SHEDULE MARK SIZE WIDTHxHEIGHT QUANTITY REMARKS 1 3'-0" x 6'-8" 1 36" HOLLOW CORE EXTERIOR DOOR 6-PANEL PAINTED WHITE 2 2'-10" x 6'-8" 3 3 6'-0" x 6'-8" 2 DOUBLE SLIDING DOOR 2 PANEL PAINTED WHITE 4 34" INTERIOR 6 PANEL WOOD 6-PANEL PAINTED WHITE D 3'-0" x 4'-0" 1 DOUBLE HUNG WINDOW TEMPERED VINYL 4'-0" x 4'-0" 1 SLIDING DOUBLE WINDOW TEMPERED VINYL U-FACTOR SHGC 1 2'-10" x 6'-8" 34" INTERIOR MINIMUM 100 SI LOUVERED DOOR 2-PANEL PAINTED WHITE 0.3 0.3 0.3 0.3 0.3 0.23 0.23 0.23 0.23 0.235 -- ----- --------- 6-PANEL PAINTED WHITE FIN. FLOOR 0' -0" FIN. FLOOR 0' -0" TOP PLATES 8' -0" FIN.GRADE -0' -6" FIN.GRADE -0' -6" TOP ROOF 11' -8"TOP ROOF. 11' -0" TOP PLATES ADU 9' -0" 4 NEW EXIST.2 2 1 36 CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. DESIGNER: PROJECT: SA I N T A N N E R E S I D E N C E A. D . U . 15 2 9 W S A I N T A N N E P L . U N I T 2 SA N T A A N A , C A 9 2 7 0 4 PR O J E C T A D D R E S S : MARK DATE REVISION TITLE: SHEET NUMBER OF SHEETS JOB NO. 24-410 DRAWN: GH CHEKED: GH DATE: FEB 12 25 7-19-25 A2.3 SCALE: 1/4" = 1'-0"1 SOUTH ELEVATION WITH WALL SCALE:2 FRONT WALL FRONT WALL 3D FIN. FLOOR 0' -0" FIN. FLOOR 0' -0" TOP PLATES 8' -0" TOP PLATES 8' -0" FIN.GRADE -0' -6" FIN.GRADE -0' -6" TOP ROOF. 11' -0" TOP ROOF. 11' -0" FIN. FLOOR 0' -0" FIN. FLOOR 0' -0" TOP PLATES 8' -0" TOP PLATES 8' -0" FIN.GRADE -0' -6" FIN.GRADE -0' -6" TOP ROOF. 11' -0" TOP ROOF. 11' -0" 8 FIN. FLOOR 0' -0" FIN. FLOOR 0' -0" TOP PLATES 8' -0" TOP PLATES 8' -0" FIN.GRADE -0' -6" FIN.GRADE -0' -6" TOP ROOF. 11' -0" TOP ROOF. 11' -0" FIN. FLOOR 0' -0" FIN. FLOOR 0' -0" TOP PLATES 8' -0" TOP PLATES 8' -0" FIN.GRADE -0' -6" FIN.GRADE -0' -6" TOP ROOF. 11' -0" TOP ROOF. 11' -0" 8 10 CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. DESIGNER: PROJECT: SA I N T A N N E R E S I D E N C E A. D . U . 15 2 9 W S A I N T A N N E P L . U N I T 2 SA N T A A N A , C A 9 2 7 0 4 PR O J E C T A D D R E S S : MARK DATE REVISION TITLE: SHEET NUMBER OF SHEETS JOB NO. 24-410 DRAWN: GH CHEKED: GH DATE: FEB 12 25 7-19-25 A3.0 EXISTING ELEVATIONS SCALE: 1/4" = 1'-0"1 (E) EAST ELEVATION SCALE: 1/4" = 1'-0"2 (E) NORTH ELEVATION SCALE: 1/4" = 1'-0"4 (E) SOUTH ELEVATION SCALE: 1/4" = 1'-0"3 (E) WEST ELEVATION FIN. FLOOR 0' -0" FIN. FLOOR 0' -0" TOP PLATES 8' -0" FIN.GRADE -0' -6" FIN.GRADE -0' -6" TOP ROOF. 11' -0" 2 2 1 TOP ROOF ' 11' -8" 42 TOP PLATES ADU 9' -0" 5 STUCCO TO MATCH EXISTENT STUCCO ON HOUSE. 8 2 FIN. FLOOR 0' -0" FIN. FLOOR 0' -0" TOP PLATES 8' -0" FIN.GRADE -0' -6" FIN.GRADE -0' -6" TOP ROOF 11' -8"TOP ROOF. 11' -0" 4 NEW EXIST.2 2 1 3 TOP PLATES ADU 9' -0" 611 FIN. FLOOR 0' -0" FIN. FLOOR 0' -0" TOP PLATES 8' -0" FIN.GRADE -0' -6" FIN.GRADE -0' -6" TOP ROOF. 11' -0" 2 1 NEWEXIST. TOP ROOF ' 11' -8" 2 4 TOP PLATES ADU 9' -0" 8 5 FIN. FLOOR 0' -0" FIN. FLOOR 0' -0" TOP PLATES 8' -0" TOP PLATES 8' -0" FIN.GRADE -0' -6" FIN.GRADE -0' -6" TOP ROOF. 11' -0"TOP ROOF, 10' -2 3/8" 4 TOP ROOF ' 11' -8" 8 CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. DESIGNER: PROJECT: SA I N T A N N E R E S I D E N C E A. D . U . 15 2 9 W S A I N T A N N E P L . U N I T 2 SA N T A A N A , C A 9 2 7 0 4 PR O J E C T A D D R E S S : MARK DATE REVISION TITLE: SHEET NUMBER OF SHEETS JOB NO. 24-410 DRAWN: GH CHEKED: GH DATE: FEB 12 25 7-19-25 A3.2 KEYNOTES THE KEY NOTES DIRECTLY BELOW REFER TO THE ELEVATIONS ONLY UNDER FLOOR VENTILATION 1 2 3 5 6 7 9 10 4 8 11 7/8" PORTLAND CEMENT PLASTER (STUCCO) OVER METAL LATH 3/8" SCRATCH COAT, 3/8" BROWN COAT, 1/8" FINISH COAT (ICC-ES ESR -2564). APPLY OVER 2-LAYERS GRADE-D PAPER OVER PLYWOOD SHEATHING (MATCH TO EXISTING) (SEE STRUCTURAL FOR PLYWOOD GRADE & THICKNESS). TYP. WINDOW, SEE WINDOW SCHEDULE ON PAGE A2.2 FOR SIZE, TYPE, AND MFR. DOOR, SEE DOOR SCHEDULE ON SHEET A2.2 FOR SIZE, TYPE, AND MFR. ROOF SEE ROOF PLAN ON SHEET A4.0 FOR ROOF TYPE, MANUFACTURER, UNDERLAYMENT, AND ADDITIONAL NOTES. (MATCH TO EXISTING). ELEVATIONS SCALE: 1/4" = 1'-0"1 WEST ELEVATION SCALE: 1/4" = 1'-0"2 SOUTH ELEVATION SCALE: 1/4" = 1'-0"3 NORTH ELEVATION ICC ES ESR-1066 Vinyl siding complying with ASTM D3679 (without foam plastic backing) or ASTM D7793 (with foam plastic backing) and is limited to siding located on exterior walls. OR SIMILAR APPROVED. SCALE: 1/4" = 1'-0"4 EAST ELEVATION ENCLOSED TANKLESS WATER HEATER PORCH -------- EXISTING ENCLOSED WATER HEATER NEW ENCLOSED THANKLESS WATER HEATER REMOVE DOOR AND FILL OUT THE OPENING PREPARE FOR NEW WINDOW "TIMBERLINE HD" ASPHALT SHINGLES (CLASS-A) BY GAF MATERIALS CORPORATION (ICC-ESR #3267) OVER UNDERLAYMENT PER ROOF PLAN NOTES. TO MATCH EXISTENT. (OR APPROVED EQUAL) 3 OVERHANG OV E R H A N G SLOPE 2:12 SLOPE 2:12 2 3 SLOPE 2:12 SLOPE 2:12 3' OF NON-COMBUSTIBLE OR IGNITION RESISTANT MATERIAL SLOPE 2:12SLOPE 2:12 SL O P E 2 : 1 2 SL O P E 2 : 1 2 2' - 4 " 1 1 2' - 4" 2 2 22 SQ.FT. PORCH 3' - 0" R327.1.1 Reinforcement for Grab Bars At least one bathroom on the entry level shall be provided with reinforcement installed in accordance with this section. Where there is no bathroom on the entry level, at least one bathroom on the second or third floor of the dwelling shall comply with this section. Reinforcement shall be solid lumber or other construction materials approved by the enforcing agency. Reinforcement shall not be less than 2 by 8 inch (51 mm by 203 mm) nominal lumber. [11/2 inch by 71/4 inch (38 mm by 184 mm) actual dimension] or other construction material providing equal height and load capacity. Reinforcement shall be located between 32 inches (812.8 mm) and 391/4 inches (997 mm) above the finished floor flush with the wall framing. Water closet reinforcement shall be installed on both side walls of the fixture, or one side wall and the back wall. Shower reinforcement shall be continuous where wall framing is provided. Bathtub and combination bathtub/shower reinforcement shall be continuous on each end of the bathtub and the back wall. Additionally, back wall reinforcement for a lower grab bar shall be provided with the bottom edge located no more than 6 inches (152.4 mm) above the bathtub rim. Exceptions: Where the water closet is not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom shall have provisions for installation of floor-mounted, foldaway or similar alternate grab bar reinforcements approved by the enforcing agency. Reinforcement shall not be required in wall framing for pre-fabricated shower enclosures and bathtub wall panels with integral factory-installed grab bars or when factory-installed reinforcement for grab bars is provided. Shower enclosures that do not permit installation of reinforcement and/or grab bars shall be permitted, provided reinforcement for installation of floor-mounted grab bars or an alternate method is approved by the enforcing agency. Bathtubs with no surrounding walls, or where wall panels do not permit the installation of reinforcement shall be permitted, provided reinforcement for installation of floor-mounted grab bars adjacent to the bathtub or an alternate method is approved by the enforcing agency. Reinforcement of floors shall not be required for bathtubs and water closets installed on concrete slab floors. R327.1.1.1 Documentation for Grab Bar Reinforcement Information and/or drawings identifying the location of grab bar reinforcement shall be placed in the operation and maintenance manual in accordance with the California Green Building Standards Code, Chapter 4, Division 4.4. R327.1.2 Electrical Receptacle Outlet, Switch and Control Heights Electrical receptacle outlets, switches and controls (including controls for heating, ventilation and air conditioning) intended to be used by occupants shall be located no more than 48 inches (1219.2 mm) measured from the top of the outlet box and not less than 15 inches (381 mm) measured from the bottom of the outlet box above the finish floor. Exceptions: Dedicated receptacle outlets; floor receptacle outlets; controls mounted on ceiling fans and ceiling lights; and controls located on appliances. Receptacle outlets required by the California Electrical Code on a wall space where the distance between the finished floor and a built-in feature above the finish floor, such as a window, is less than 15 inches (381 mm). R327.1.3 Interior Doors Effective July 1, 2024, at least one bathroom and one bedroom on the entry level shall provide a doorway with a net clear opening of not less than 32 inches (812.8 mm), measured with the door positioned at an angle of 90 degrees from the closed position; or, in the case of a two-or three-story single family dwelling, on the second or third floor of the dwelling if a bathroom or bedroom is not located on the entry level. R327.1.4 Doorbell Buttons Doorbell buttons or controls, when installed, shall not exceed 48 inches (1219.2 mm) above exterior floor or landing, measured from the top of the doorbell button assembly. Where doorbell buttons integrated with other features are required to be installed above 48 inches (1219.2 mm) measured from the exterior floor or landing, a standard doorbell button or control shall also be provided at a height not exceeding 48 inches (1219.2 mm) above exterior floor or landing, measured from the top of the doorbell button or control. (n) WATER HEATING SYSTEM. 1. Systems using gas or propane water heaters to serve individual dwelling units shall designate a space at least 2.5 feet by 2.5 feet wide and 7 feet tall suitable for the future installation of a heat pump water heater (HPWH) by meeting either A or B below. All electrical components shall be installed in accordance with the California Electrical Code: A. If the designated space is within 3 feet from the water heater, then this space shall include the following: i. A dedicated 125 volt, 20 amp electrical receptacle that is connected to the electric panel with a 120/240 volt 3 conductor, 10 AWG copper branch circuit, within 3 feet from the water heater and accessible to the water heater with no obstructions; and ii. Both ends of the unused conductor shall be labeled with the word “spare”and be electrically isolated; and iii. A reserved single pole circuit breaker space in the electrical panel adjacent to the circuit breaker for the branch circuit in A above and labeled with the words “Future 240V Use”; and iv. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance. B. If the designated space is more than 3 feet from the water heater, then this space shall include the following: i. A dedicated 240 volt branch circuit shall be installed within 3 feet from the designated space. The branch circuit shall be rated at 30 amps minimum. The blank cover shall be identified as “240V ready”; and ii. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a future HPWH installation. The reserved space shall be permanently marked as “For Future 240V use”; and iii. Either a dedicated cold water supply, or the cold water supply shall pass through the designated HPWH location just before reaching the gas or propane water heater; and iv. The hot water supply pipe coming out of the gas or propane water heater shall be routed first through the designated HPWH location before serving any fixtures; and v. The hot and cold water piping at the designated HPWH location shall be exposed and readily accessible for future installation of an HPWH; and vi. A condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance. 2. Water heating recirculation loops serving multiple dwelling units shall meet the requirements of Section 110.3(c)4. 3. Solar water-heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC), the International Association of Plumbing and Mechanical Officials, Research and Testing (IAPMO R&T), or by a listing agency that is approved by the Executive Director. 4. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2kW) shall meet the requirements of Section 110.3(c)6. 1 HOUR FIRE RATED EAVE SEE DETAIL 4 IN A2.2 2' - 2 " 4' - 6 " 11' - 4" SCALE: 1/4" = 1'-0"1 ROOF PLAN CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. DESIGNER: PROJECT: SA I N T A N N E R E S I D E N C E A. D . U . 15 2 9 W S A I N T A N N E P L . U N I T 2 SA N T A A N A , C A 9 2 7 0 4 PR O J E C T A D D R E S S : MARK DATE REVISION TITLE: SHEET NUMBER OF SHEETS JOB NO. 24-410 DRAWN: GH CHEKED: GH DATE: FEB 12 25 7-19-25 A4.0 GABLE VENTS 18x24; 140 NFA BUILDERS EDGE OR SIMILAR PRODUCT. 12X24 IN. DIA. HALF ROUND DORMER VENT; 100 NFA GIBRALTAR BUILDING PRODUCTS OR SIMILAR PRODUCT. VENTSURE SKY RUNNER LTE ROLLED RIDGE VENT NET FREE VENT AREA (NFVA) 12 SQ. IN. PER LINEAL FT. BY OWENS CORNING ROOFING AND ASPHALT, LLC. REQUIRED VENT AREA: 784.00 / 150 x 144 = 752.64 SQ. IN./2 376.32 INTAKE 376.32 EXHAUST INTAKE PROVIDED VENT AREA: 2-24X16 IN. GABLE VENTS: 2 @ 120 NFA= 240 SQ.IN. 3-24 IN. DIA. HALF ROUND VENTS: 2 @ 100 NFA= 200 SQ.IN. TOTAL = 440 SQ. IN. O.K. EXHAUST PROVIDED VENT AREA: ROLLED RIDGE VENT: 36 @ 12 NFA= 432 SQ.IN. TOTAL = 432 SQ. IN. O.K. ROOF PLAN KEYNOTES THE KEY NOTES DIRECTLY BELOW REFER TO THE ROOF PLAN ONLY 1 2 3 5 6 7 4 ROOF PLAN NOTES ATTIC VENTILATION 1. ASPHALT SHINGLES MAY BE INSTALLED IN SLOPES AS LOW AS 2 UNITS VERTICAL IN 12 UNITS HORIZONTAL, PROVIDED THE SHINGLES ARE APPROVED SELF-SEALING OR HAND SEALED AND ARE INSTALLED WITH AN UNDERLAYMENT CONSISTING OF TWO LAYERS OF NONPERFORATED TYPE 15 FELT APPLIED SHINGLE FASHION. STARTING WITH AN 18-INCH -WIDE SHEET AND A 36-WIDE SHEET OVER IT AT THE EAVES, EACH SUBSEQUENT SHEET SHALL BE LAPPED 19 INCHES HORIZONTALLY. 2. FOR SLOPES OF 4 UNITS VERTICAL IN 12 UNITS HORIZONTAL OR STEEPER, USE ONE LAYER NONPERFORATED TYPE 15 FELT LAPPED 2 INCHES HORIZONTALLY AND 4 INCHES VERTICALLY TO SHED WATER. 3. FASTEN SHINGLES WITH CORROSION-RESISTANT NAILS, MINIMUM 12-GAGE WITH 3/8 INCH HEAD, OR APPROVED CORROSION-RESISTANT STAPLES, MINIMUM 16-GAGE 15/16 CROWN WIDTH. FASTENERS SHALL BE LONG ENOUGH TO PENETRATE INTO THE SHEATHING 3/4 INCH OR THROUGH THICKNESS OF THE SHEATHING, WHICHEVER IS LESS. INSTALL FOUR FASTENERS FOR STRIP ASPHALT SHINGLES 36 INCHES TO 40 INCHES IN WIDTH. 4. THE ROOF VALLEY FLASHING SHALL NOT BE PROVIDED OF LESS THAN 0.016-INCH (No. 28 GALVANIZED SHEET GAGE) CORROSION-RESISTANT METAL, AND SHALL EXTEND AT LEAST 8 INCHES (203 mm) FROM THE CENTER LINE EACH WAY. SECTIONS OF FLASHING SHALL HAVE AN END LAP OF NOT LESS THAN 4 INCHES. ALTERNATIVELY, THE VALLEY SHALL CONSIST OF WOVEN ASPHALT SHINGLES APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S PRINTED INSTRUCTIONS. 5. THE ROOF VALLEY FLASHING SHALL HAVE A 36-INCH-WIDE UNDERLAYMENT DIRECTLY UNDER IT CONSISTING OF ONE LAYER OF TYPE 15 FELT RUNNING THE FULL LENGTH OF THE VALLEY, IN ADDITION TO THE UNDERLAYMENT SPECIFIED ABOVE. 6. AT THE JUNCTURE OF THE ROOF AND VERTICAL SURFACES, PROVIDE 'Z' FLASHING NOT LESS THAN 0.019-INCH (No. 26 GALVANIZED SHEET GAGE) CORROSION-RESISTANT METAL TO 1x4 BACKING. STEP COUNTER FLASHINIG SHALL BE INSTALLED WHERE THE 'Z' BAR FLASHING SLOPES WITH THE ROOF. 'L' METAL COUNTER FLASHING SHALL BE INSTALLED WHERE THE ROOF SLOPES AWAY FROM THE 'Z' BAR FLASHING. 7. OPENINGS FOR ATTIC VENTILATION SHALL BE COVERED WITH CORROSION-RESISTANT METAL MESH WITH MESH OPENINGS OF 1/4-INCH IN DIMENSION. FIN. FLOOR 0' -0" FIN. FLOOR 0' -0" FIN.GRADE -0' -6" FIN.GRADE -0' -6" TOP ROOF ' 11' -8" TOP ROOF ' 11' -8" 9 3 2 1 11 6 5 8 13 12 14 4 TOP PLATES ADU 9' -0" TOP PLATES ADU 9' -0" 10 FIN. FLOOR 0' -0" FIN.GRADE -0' -6" TOP ROOF ' 11' -8" 9 3 2 1 11 6 5 8 13 12 4 14 TOP PLATES ADU 9' -0" 7 CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. DESIGNER: PROJECT: SA I N T A N N E R E S I D E N C E A. D . U . 15 2 9 W S A I N T A N N E P L . U N I T 2 SA N T A A N A , C A 9 2 7 0 4 PR O J E C T A D D R E S S : MARK DATE REVISION TITLE: SHEET NUMBER OF SHEETS JOB NO. 24-410 DRAWN: GH CHEKED: GH DATE: FEB 12 25 7-19-25 A4.1 7/8" PORTLAND CEMENT PLASTER (STUCCO) OVER METAL LATH 3/8" SCRATCH COAT, 3/8" BROWN COAT, 1/8" FINISH COAT. APPLY OVER 2-LAYERS GRADE-D PAPER OVER PLYWOOD SHEATHING (SEE STRUCTURAL FOR PLYWOOD GRADE & THICKNESS). TYP. PLYWOOD SHEATHING, SEE STRUCTURAL. STUD WALLS, SEE STRUCTURAL. CEILING JOIST, SEE STRUCTURAL. ROOF FRAMING, SEE STRUCTURAL. SEE ROOF FRAMING PLAN ON SHEET A4.0 FOR ROOF TYPE, MANUFACTURER, UNDERLAYMENT, AND ADDITIONAL NOTES. FOUNDATION, SEE STRUCTURAL. RIDGE BOARD. 2x6 FASCIA R-21 WALL INSULATION. R-30 CEILING INSULATION. 1/2" GYPSUM BOARD AT WALL. 1/2" GYPSUM BOARD AT CEILING. EXPOSED ROOF RAFTERS. KEYNOTES THE KEY NOTES DIRECTLY BELOW REFER THE SECTION ONLY 1 2 3 5 6 7 9 10 4 8 11 12 13 15 16 17 19 20 14 18 SECTION SCALE: 1/4" = 1'-0"1 Section 1 SCALE: 1/4" = 1'-0"2 Section 2 SPLIT SYSTEM INDOOR UNIT SPLIT SYSTEM OUTDOOR UNIT PIONEER Air Conditioner WYS020GMHI22M2 Multi Heat Pump, Dual Split (2 Zone) 1-HR FIRE RATED & SOUND STRUCTURAL NOTES S1.0 SHEET NUMBER PR O J E C T A D D R E S S : SHEETSOF REVISIONS CONSTRUCTION SHALL CONFORMTO THE ENGINEER. ALLWORK. REPORT DISCREPANCIESBEFORE PROCEEDING WITH THECHECK AND VERIFY ALL DIMENSIONS DRAWN : CHECKED : DATE : JOB NO. TO THE C.B.C. MARK DATE PROJECT: 24-463 ANAHI ANAHI 15 AUG 25 . . . . . . . . . . . . TITLE AD D I T I O N 15 2 9 W S T . A N N E P L 3 1 2 3 1147 E MARKET ST. LONG BEACH, CA 90805 T:562-961-5600 ENGINEER: Margarito Castillo, S.E. CASTILLO ENGINEERING 15 2 9 W S T . A N N E P L SA N T A A N A , C A 9 2 7 0 4 WWW.CASTILLOENGINEERING.COM STRUCTURAL NOTES TYPICAL DETAIL1TYPICAL DETAIL2TYPICAL DETAIL4 TYPICAL DETAIL5TYPICAL DETAIL6TYPICAL DETAIL7TYPICAL DETAIL8 TYPICAL DETAIL12 TYPICAL DETAIL11 TYPICAL DETAIL10 TYPICAL DETAIL9 TYPICAL DETAIL3 S1.1 SHEET NUMBER PR O J E C T A D D R E S S : SHEETSOF REVISIONS CONSTRUCTION SHALL CONFORMTO THE ENGINEER. ALLWORK. REPORT DISCREPANCIESBEFORE PROCEEDING WITH THECHECK AND VERIFY ALL DIMENSIONS DRAWN : CHECKED : DATE : JOB NO. TO THE C.B.C. MARK DATE PROJECT: 24-463 ANAHI ANAHI 15 AUG 25 . . . . . . . . . . . . TITLE AD D I T I O N 15 2 9 W S T . A N N E P L 3 1 2 3 1147 E MARKET ST. LONG BEACH, CA 90805 T:562-961-5600 ENGINEER: Margarito Castillo, S.E. CASTILLO ENGINEERING 15 2 9 W S T . A N N E P L SA N T A A N A , C A 9 2 7 0 4 WWW.CASTILLOENGINEERING.COM TYPICAL DETAILS TYPICAL DETAIL2TYPICAL DETAIL4 TYPICAL DETAIL5TYPICAL DETAIL8 TYPICAL DETAIL12 TYPICAL DETAIL9TYPICAL DETAIL10 S1.2 SHEET NUMBER PR O J E C T A D D R E S S : SHEETSOF REVISIONS CONSTRUCTION SHALL CONFORMTO THE ENGINEER. ALLWORK. REPORT DISCREPANCIESBEFORE PROCEEDING WITH THECHECK AND VERIFY ALL DIMENSIONS DRAWN : CHECKED : DATE : JOB NO. TO THE C.B.C. MARK DATE PROJECT: 24-463 ANAHI ANAHI 15 AUG 25 . . . . . . . . . . . . TITLE AD D I T I O N 15 2 9 W S T . A N N E P L 3 1 2 3 1147 E MARKET ST. LONG BEACH, CA 90805 T:562-961-5600 ENGINEER: Margarito Castillo, S.E. CASTILLO ENGINEERING 15 2 9 W S T . A N N E P L SA N T A A N A , C A 9 2 7 0 4 WWW.CASTILLOENGINEERING.COM TYPICAL DETAILS TYPICAL DETAIL1TYPICAL DETAIL2TYPICAL DETAIL4 TYPICAL DETAIL12 TYPICAL DETAIL11 TYPICAL DETAIL3 TYPICAL DETAIL9TYPICAL DETAIL10 S1.3 SHEET NUMBER PR O J E C T A D D R E S S : SHEETSOF REVISIONS CONSTRUCTION SHALL CONFORMTO THE ENGINEER. ALLWORK. REPORT DISCREPANCIESBEFORE PROCEEDING WITH THECHECK AND VERIFY ALL DIMENSIONS DRAWN : CHECKED : DATE : JOB NO. TO THE C.B.C. MARK DATE PROJECT: 24-463 ANAHI ANAHI 15 AUG 25 . . . . . . . . . . . . TITLE AD D I T I O N 15 2 9 W S T . A N N E P L 3 1 2 3 1147 E MARKET ST. LONG BEACH, CA 90805 T:562-961-5600 ENGINEER: Margarito Castillo, S.E. CASTILLO ENGINEERING 15 2 9 W S T . A N N E P L SA N T A A N A , C A 9 2 7 0 4 WWW.CASTILLOENGINEERING.COM TYPICAL DETAILS N1FOUNDATION PLAN SHEET NUMBER PR O J E C T A D D R E S S : SHEETSOF REVISIONS CONSTRUCTION SHALL CONFORMTO THE ENGINEER. ALLWORK. REPORT DISCREPANCIESBEFORE PROCEEDING WITH THECHECK AND VERIFY ALL DIMENSIONS DRAWN : CHECKED : DATE : JOB NO. TO THE C.B.C. MARK DATE PROJECT: 24-463 ANAHI ANAHI 23 JAN 25 . . . . . . . . . . . . TITLE AD D T I O N 15 2 9 W S T . A N N E P L 3 1 2 3 1147 E MARKET ST. LONG BEACH, CA 90805 T:562-961-5600 ENGINEER: Margarito Castillo, S.E. Expires 12-31-26 NO. 4808 CASTILLO ENGINEERING 15 2 9 W S T . A N N E P L SA N T A A N A , C A 9 2 7 0 4 WWW.CASTILLOENGINEERING.COM S2.0 FOUNDATION PLAN N1ROOF FRAMING PLAN C.J. C. J . C.J.C.J. SHEET NUMBER PR O J E C T A D D R E S S : SHEETSOF REVISIONS CONSTRUCTION SHALL CONFORMTO THE ENGINEER. ALLWORK. REPORT DISCREPANCIESBEFORE PROCEEDING WITH THECHECK AND VERIFY ALL DIMENSIONS DRAWN : CHECKED : DATE : JOB NO. TO THE C.B.C. MARK DATE PROJECT: 24-463 ANAHI ANAHI 23 JAN 25 . . . . . . . . . . . . TITLE AD D T I O N 15 2 9 W S T . A N N E P L 3 1 2 3 1147 E MARKET ST. LONG BEACH, CA 90805 T:562-961-5600 ENGINEER: Margarito Castillo, S.E. Expires 12-31-26 NO. 4808 CASTILLO ENGINEERING 15 2 9 W S T . A N N E P L SA N T A A N A , C A 9 2 7 0 4 WWW.CASTILLOENGINEERING.COM S2.2 ROOF FRAMING PLAN DETAIL1DETAIL2DETAIL4 DETAIL5DETAIL6DETAIL7DETAIL8 DETAIL12 DETAIL11 DETAIL10 DETAIL9 DETAIL3 S3.0 SHEET NUMBER PR O J E C T A D D R E S S : SHEETSOF REVISIONS CONSTRUCTION SHALL CONFORM TO THE ENGINEER. ALL WORK. REPORT DISCREPANCIES BEFORE PROCEEDING WITH THE CHECK AND VERIFY ALL DIMENSIONS DRAWN : CHECKED : DATE : JOB NO. TO THE C.B.C. MARK DATE PROJECT: 24-463 ANAHI ANAHI 15 AUG 25 . . . . . . . . . . . . TITLE AD D I T I O N 15 2 9 W S T . A N N E P L 3 1 2 3 1147 E MARKET ST. LONG BEACH, CA 90805 T:562-961-5600 ENGINEER: Margarito Castillo, S.E. CASTILLO ENGINEERING 15 2 9 W S T . A N N E P L SA N T A A N A , C A 9 2 7 0 4 WWW.CASTILLOENGINEERING.COM FOUNDATION DETAILS DETAIL1DETAIL2DETAIL4 DETAIL5DETAIL6DETAIL7DETAIL8 DETAIL12 DETAIL11 DETAIL10 DETAIL9 DETAIL3 S5.0 SHEET NUMBER PR O J E C T A D D R E S S : SHEETSOF REVISIONS CONSTRUCTION SHALL CONFORMTO THE ENGINEER. ALLWORK. REPORT DISCREPANCIESBEFORE PROCEEDING WITH THECHECK AND VERIFY ALL DIMENSIONS DRAWN : CHECKED : DATE : JOB NO. TO THE C.B.C. MARK DATE PROJECT: 24-463 ANAHI ANAHI 15 AUG 25 . . . . . . . . . . . . TITLE AD D I T I O N 15 2 9 W S T . A N N E P L 3 1 2 3 1147 E MARKET ST. LONG BEACH, CA 90805 T:562-961-5600 ENGINEER: Margarito Castillo, S.E. CASTILLO ENGINEERING 15 2 9 W S T . A N N E P L SA N T A A N A , C A 9 2 7 0 4 WWW.CASTILLOENGINEERING.COM ROOF FRAMING DETAILS CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. DESIGNER: PROJECT: SA I N T A N N E R E S I D E N C E A. D . U . 15 2 9 W S A I N T A N N E P L . U N I T 2 SA N T A A N A , C A 9 2 7 0 4 PR O J E C T A D D R E S S : MARK DATE REVISION TITLE: JOB NO. 24-410 DRAWN: GH GH CHECKED: DATE: FEB 12 25 SHEET NUMBER OF SHEETS 7-19-25 T-1 TITLE 24 CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. DESIGNER: PROJECT: SA I N T A N N E R E S I D E N C E A. D . U . 15 2 9 W S A I N T A N N E P L . U N I T 2 SA N T A A N A , C A 9 2 7 0 4 PR O J E C T A D D R E S S : MARK DATE REVISION TITLE: JOB NO. 24-410 DRAWN: GH GH CHECKED: DATE: FEB 12 25 SHEET NUMBER OF SHEETS 7-19-25 T-2 RES MANDATORY REQ SUMMARY CHAPTER 4 RESIDENTIAL MANDATORY MEASURES DIVISION 4.1 PLANNING AND DESIGN DIVISION 4.3 WATER EFFICIENCY AND CONSERVATION 4.406 ENHANCED DURABILITY AND REDUCED MAINTENANCE 4.406.1 RODENT PROOFING. Annular spaces around pipes, electric cables, conduits or other openings in sole/bottom plates at exterior walls shall be protected against the passage of rodents by closing such openings with cement mortar, concrete masonry or a similar method acceptable to the enforcing agency. 4.408 CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING 4.408.1 CONSTRUCTION WASTE MANAGEMENT. Recycle and/or salvage for reuse a minimum of 65 percent of the non-hazardous construction and demolition waste in accordance with either Section 4.408.2, 4.408.3 or 4.408.4, or meet a more stringent local construction and demolition waste management ordinance. Exceptions: 1. Excavated soil and land-clearing debris. 2. Alternate waste reduction methods developed by working with local agencies if diversion or recycle facilities capable of compliance with this item do not exist or are not located reasonably close to the jobsite. 3. The enforcing agency may make exceptions to the requirements of this section when isolated jobsites are located in areas beyond the haul boundaries of the diversion facility. 4.408.2 CONSTRUCTION WASTE MANAGEMENT PLAN. Submit a construction waste management plan in conformance with Items 1 through 5. The construction waste management plan shall be updated as necessary and shall be available during construction for examination by the enforcing agency. 1. Identify the construction and demolition waste materials to be diverted from disposal by recycling, reuse on the project or salvage for future use or sale. 2. Specify if construction and demolition waste materials will be sorted on-site (source separated) or bulk mixed (single stream). 3. Identify diversion facilities where the construction and demolition waste material collected will be taken. 4. Identify construction methods employed to reduce the amount of construction and demolition waste generated. 5. Specify that the amount of construction and demolition waste materials diverted shall be calculated by weight or volume, but not by both. 4.408.3 WASTE MANAGEMENT COMPANY. Utilize a waste management company, approved by the enforcing agency, which can provide verifiable documentation that the percentage of construction and demolition waste material diverted from the landfill complies with Section 4.408.1. Note: The owner or contractor may make the determination if the construction and demolition waste materials will be diverted by a waste management company. 4.408.4 WASTE STREAM REDUCTION ALTERNATIVE [LR]. Projects that generate a total combined weight of construction and demolition waste disposed of in landfills, which do not exceed 3.4 lbs./sq.ft. of the building area shall meet the minimum 65% construction waste reduction requirement in Section 4.408.1 4.408.4.1 WASTE STREAM REDUCTION ALTERNATIVE. Projects that generate a total combined weight of construction and demolition waste disposed of in landfills, which do not exceed 2 pounds per square foot of the building area, shall meet the minimum 65% construction waste reduction requirement in Section 4.408.1 4.408.5 DOCUMENTATION. Documentation shall be provided to the enforcing agency which demonstrates compliance with Section 4.408.2, items 1 through 5, Section 4.408.3 or Section 4.408.4.. Notes: 1. Sample forms found in "A Guide to the California Green Building Standards Code (Residential)" located at www.hcd.ca.gov/CALGreen.html may be used to assist in documenting compliance with this section. 2. Mixed construction and demolition debris (C & D) processors can be located at the California Department of Resources Recycling and Recovery (CalRecycle). 4.410 BUILDING MAINTENANCE AND OPERATION 4.410.1 OPERATION AND MAINTENANCE MANUAL. At the time of final inspection, a manual, compact disc, web-based reference or other media acceptable to the enforcing agency which includes all of the following shall be placed in the building: 1. Directions to the owner or occupant that the manual shall remain with the building throughout the life cycle of the structure. 2. Operation and maintenance instructions for the following: a. Equipment and appliances, including water-saving devices and systems, HVAC systems, photovoltaic systems, electric vehicle chargers, water-heating systems and other major appliances and equipment. b. Roof and yard drainage, including gutters and downspouts. c. Space conditioning systems, including condensers and air filters. d. Landscape irrigation systems. e. Water reuse systems. 3. Information from local utility, water and waste recovery providers on methods to further reduce resource consumption, including recycle programs and locations. 4. Public transportation and/or carpool options available in the area. 5. Educational material on the positive impacts of an interior relative humidity between 30-60 percent and what methods an occupant may use to maintain the relative humidity level in that range. 6. Information about water-conserving landscape and irrigation design and controllers which conserve water. 7. Instructions for maintaining gutters and downspouts and the importance of diverting water at least 5 feet away from the foundation. 8. Information on required routine maintenance measures, including, but not limited to, caulking, painting, grading around the building, etc. 9. Information about state solar energy and incentive programs available. 10. A copy of all special inspections verifications required by the enforcing agency or this code. 11. Information from the Department of Forestry and Fire Protection on maintenance of defensible space around residential structures. 12. Information and/or drawings identifying the location of grab bar reinforcements. 4.410.2 RECYCLING BY OCCUPANTS. Where 5 or more multifamily dwelling units are constructed on a building site, provide readily accessible area(s) that serves all buildings on the site and are identified for the depositing, storage and collection of non-hazardous materials for recycling, including (at a minimum) paper, corrugated cardboard, glass, plastics, organic waster, and metals, or meet a lawfully enacted local recycling ordinance, if more restrictive. Exception: Rural jurisdictions that meet and apply for the exemption in Public Resources Code Section 42649.82 (a)(2)(A) et seq. are note required to comply with the organic waste portion of this section. DIVISION 4.4 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY DIVISION 4.5 ENVIRONMENTAL QUALITY 4.303 INDOOR WATER USE 4.303.1 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS. Plumbing fixtures (water closets and urinals) and fittings (faucets and showerheads) shall comply with the sections 4.303.1.1, 4.303.1.2, 4.303.1.3, and 4.303.4.4. Note: All noncompliant plumbing fixtures in any residential real property shall be replaced with water-conserving plumbing fixtures. Plumbing fixture replacement is required prior to issuance of a certificate of final completion, certificate of occupancy, or final permit approval by the local building department. See Civil Code Section 1101.1, et seq., for the definition of a noncompliant plumbing fixture, types of residential buildings affected and other important enactment dates. 4.303.1.1 Water Closets. The effective flush volume of all water closets shall not exceed 1.28 gallons per flush. Tank-type water closets shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for Tank-type Toilets. Note: The effective flush volume of dual flush toilets is defined as the composite, average flush volume of two reduced flushes and one full flush. 4.303.1.2 Urinals. The effective flush volume of wall mounted urinals shall not exceed 0.125 gallons per flush. The effective flush volume of all other urinals shall not exceed 0.5 gallons per flush. 4.303.1.3 Showerheads. 4.303.1.3.1 Single Showerhead. Showerheads shall have a maximum flow rate of not more than 1.8 gallons per minute at 80 psi. Showerheads shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for Showerheads. 4.303.1.3.2 Multiple showerheads serving one shower. When a shower is served by more than one showerhead, the combined flow rate of all the showerheads and/or other shower outlets controlled by a single valve shall not exceed 1.8 gallons per minute at 80 psi, or the shower shall be designed to only allow one shower outlet to be in operation at a time. Note: A hand-held shower shall be considered a showerhead. 4.303.1.4 Faucets. 4.303.1.4.1 Residential Lavatory Faucets. The maximum flow rate of residential lavatory faucets shall not exceed 1.2 gallons per minute at 60 psi. The minimum flow rate of residential lavatory faucets shall not be less than 0.8 gallons per minute at 20 psi. 4.303.1.4.2 Lavatory Faucets in Common and Public Use Areas. The maximum flow rate of lavatory faucets installed in common and public use areas (outside of dwellings or sleeping units) in residential buildings shall not exceed 0.5 gallons per minute at 60 psi. 4.303.1.4.3 Metering Faucets. Metering faucets when installed in residential buildings shall not deliver more than 0.2 gallons per cycle. 4.303.1.4.4 Kitchen Faucets. The maximum flow rate of kitchen faucets shall not exceed 1.8 gallons per minute at 60 psi. Kitchen faucets may temporarily increase the flow above the maximum rate, but not to exceed 2.2 gallons per minute at 60 psi, and must default to a maximum flow rate of 1.8 gallons per minute at 60 psi. Note: Where complying faucets are unavailable, aerators or other means may be used to achieve reduction. 4.303.1.4.5 Pre-rinse spray valves. When installed, shall meet the requirements in the California Code of Regulations, Title 20 (Appliance Efficiency Regulations), Sections 1605.1 (h)(4) Table H-2, Section 1605.3 (h)(4)(A), and Section 1607 (d)(7) and shall be equipped with an integral automatic shutoff. FOR REFERENCE ONLY: The following table and code section have been reprinted from the California Code of Regulations, Title 20 (Appliance Efficiency Regulations),Section 1605.1 (h)(4) and Section 1605.3 (h)(4)(A). Title 20 Section 1605.3 (h)(4)(A): Commercial prerinse spray values manufactured on or after January 1, 2006, shall have a minimum spray force of not less than 4.0 ounces-force (ozf)[113 grams-force(gf)] 4.303.2 Submeters for multifamily buildings and dwelling units in mixed-used residential/commercial buildings. Submeters shall be installed to measure water usage of individual rental dwelling units in accordance with the California Plumbing Code. 4.303.3 Standards for plumbing fixtures and fittings. Plumbing fixtures and fittings shall be installed in accordance with the California Plumbing Code, and shall meet the applicable standards referenced in Table 1701.1 of the California Plumbing Code. TABLE - MAXIMUM FIXTURE WATER USE FIXTURE TYPE FLOW RATE SHOWER HEADS (RESIDENTIAL)1.8 GMP @ 80 PSI LAVATORY FAUCETS (RESIDENTIAL)MAX. 1.2 GPM @ 60 PSI MIN. 0.8 GPM @ 20 PSI LAVATORY FAUCETS IN COMMON & PUBLIC USE AREAS 0.5 GPM @ 60 PSI KITCHEN FAUCETS 1.8 GPM @ 60 PSI METERING FAUCETS 0.2 GAL/CYCLE WATER CLOSET 1.28 GAL/FLUSH URINALS 0.125 GAL/FLUSH 4.304 OUTDOOR WATER USE 4.304.1 OUTDOOR POTABLE WATER USE IN LANDSCAPE AREAS. Residential developments shall comply with a local water efficient landscape ordinance or the current California Department of Water Resources' Model Water Efficient Landscape Ordinance (MWELO), whichever is more stringent. NOTES: 1. The Model Water Efficient Landscape Ordinance (MWELO) is located in the California Code Regulations, Title 23, Chapter 2.7, Division 2. MWELO and supporting documents, including water budget calculator, are available at: https://www.water.ca.gov/ ABBREVIATION DEFINITIONS: HCD Department of Housing and Community Development BSC California Building Standards Commission DSA-SS Division of the State Architect, Structural Safety OSHPD Office of Statewide Health Planning and Development LR Low Rise HR High Rise AA Additions and Alterations N New NOTE: THIS TABLE COMPILES THE DATA IN SECTION 4.303.1, AND IS INCLUDED AS A CONVENIENCE FOR THE USER. SECTION 4.102 DEFINITIONS 4.102.1 DEFINITIONS The following terms are defined in Chapter 2 (and are included here for reference) FRENCH DRAIN. A trench, hole or other depressed area loosely filled with rock, gravel, fragments of brick or similar pervious material used to collect or channel drainage or runoff water. WATTLES. Wattles are used to reduce sediment in runoff. Wattles are often constructed of natural plant materials such as hay, straw or similar material shaped in the form of tubes and placed on a downflow slope. Wattles are also used for perimeter and inlet controls. 4.106 SITE DEVELOPMENT 4.106.1 GENERAL. Preservation and use of available natural resources shall be accomplished through evaluation and careful planning to minimize negative effects on the site and adjacent areas. Preservation of slopes, management of storm water drainage and erosion controls shall comply with this section. 4.106.2 STORM WATER DRAINAGE AND RETENTION DURING CONSTRUCTION. Projects which disturb less than one acre of soil and are not part of a larger common plan of development which in total disturbs one acre or more, shall manage storm water drainage during construction. In order to manage storm water drainage during construction, one or more of the following measures shall be implemented to prevent flooding of adjacent property, prevent erosion and retain soil runoff on the site. 1. Retention basins of sufficient size shall be utilized to retain storm water on the site. 2. Where storm water is conveyed to a public drainage system, collection point, gutter or similar disposal method, water shall be filtered by use of a barrier system, wattle or other method approved by the enforcing agency. 3. Compliance with a lawfully enacted storm water management ordinance. Note: Refer to the State Water Resources Control Board for projects which disturb one acre or more of soil, or are part of a larger common plan of development which in total disturbs one acre or more of soil. (Website: https://www.waterboards.ca.gov/water_issues/programs/stormwater/construction.html) 4.106.3 GRADING AND PAVING. Construction plans shall indicate how the site grading or drainage system will manage all surface water flows to keep water from entering buildings. Examples of methods to manage surface water include, but are not limited to, the following: 1. Swales 2. Water collection and disposal systems 3. French drains 4. Water retention gardens 5. Other water measures which keep surface water away from buildings and aid in groundwater recharge. Exception: Additions and alterations not altering the drainage path. 4.106.4 Electric vehicle (EV) charging for new construction. New construction shall comply with Section 4.106.4.1 or 4.106.4.2. Electric vehicle supply equipment (EVSE) shall comply with the California Electrical Code. Exceptions: 1. On a case-by-case basis, where the local enforcing agency has determined EV charging and infrastructure are not feasible based upon one or more of the following conditions: 1.1 Where there is no local utility power supply or the local utility is unable to supply adequate power. 1.2 Where there is evidence suitable to the local enforcing agency substantiating that additional local utility infrastructure design requirements, directly related to the implementation of Section 4.106.4, may adversely impact the construction cost of the project. 2. Accessory Dwelling Units (ADU) and Junior Accessory Dwelling Units (JADU) without additional parking facilities. 4.106.4.1 New one- and two-family dwellings and townhouses with attached private garages. For each dwelling unit, install a listed raceway to accommodate a dedicated 208/240-volt branch circuit. The raceway shall not be less than trade size 1 (nominal 1-inch inside diameter). The raceway shall originate at the main service or subpanel and shall terminate into a listed cabinet, box or other enclosure in close proximity to the proposed location of an EV charger. Raceways are required to be continuous at enclosed, inaccessible or concealed areas and spaces. The service panel and/or subpanel shall provide capacity to install a 40-ampere 208/240-volt minimum dedicated branch circuit and space(s) reserved to permit installation of a branch circuit overcurrent protective device. Exemption: A raceway is not required if a minimum 40-ampere 208/240-volt dedicated EV branch circuit is installed in close proximity to the proposed location of an EV charger at the time of original construction in accordance with the California Electrical Code. 4.106.4.1.1 Identification. The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging as "EV CAPABLE". The raceway termination location shall be permanently and visibly marked as "EV CAPABLE". CHAPTER 3 GREEN BUILDING SECTION 301 GENERAL 301.1 SCOPE. Buildings shall be designed to include the green building measures specified as mandatory in the application checklists contained in this code. Voluntary green building measures are also included in the application checklists and may be included in the design and construction of structures covered by this code, but are not required unless adopted by a city, county, or city and county as specified in Section 101.7. 301.1.1 Additions and alterations. [HCD] The mandatory provisions of Chapter 4 shall be applied to additions or alterations of existing residential buildings where the addition or alteration increases the building's conditioned area, volume, or size. The requirements shall apply only to and/or within the specific area of the addition or alteration. The mandatory provision of Section 4.106.4.2 may apply to additions or alterations of existing parking facilities or the addition of new parking facilities serving existing multifamily buildings. See Section 4.106.4.3 for application. Note: Repairs including, but not limited to, resurfacing, restriping and repairing or maintaining existing lighting fixtures are not considered alterations for the purpose of this section. Note: On and after January 1, 2014, residential buildings undergoing permitted alterations, additions, or improvements shall replace noncompliant plumbing fixtures with water-conserving plumbing fixtures. Plumbing fixture replacement is required prior to issuance of a certificate of final completion, certificate of occupancy or final permit approval by the local building department. See Civil Code Section 1101.1, et seq., for the definition of a noncompliant plumbing fixture, types of residential buildings affected and other important enactment dates. 301.2 LOW-RISE AND HIGH-RISE RESIDENTIAL BUILDINGS. [HCD] The provisions of individual sections of CALGreen may apply to either low-rise residential buildings high-rise residential buildings, or both. Individual sections will be designated by banners to indicate where the section applies specifically to low-rise only (LR) or high-rise only (HR). When the section applies to both low-rise and high-rise buildings, no banner will be used. SECTION 302 MIXED OCCUPANCY BUILDINGS 302.1 MIXED OCCUPANCY BUILDINGS. In mixed occupancy buildings, each portion of a building shall comply with the specific green building measures applicable to each specific occupancy. Exceptions: 1. [HCD] Accessory structures and accessory occupancies serving residential buildings shall comply with Chapter 4 and Appendix A4, as applicable. 2. [HCD] For purposes of CALGreen, live/work units, complying with Section 419 of the California Building Code, shall not be considered mixed occupancies. Live/Work units shall comply with Chapter 4 and Appendix A4, as applicable. 4.106.4.2 New multifamily dwellings, hotels and motels and new residential parking facilities. When parking is provided, parking spaces for new multifamily dwellings, hotels and motels shall meet the requirements of Section 4.106.4.2.2. Calculations for spaces shall be rounded up to the nearest whole number. A parking space served by electric vehicle supply equipment or designed as an EV charging space shall count as at least one standard automobile parking space only for the purpose of complying with any applicable minimum parking space requirements established by a local jurisdiction. See Vehicle Code Section 22511.2 for further details. 4.106.4.2.1 Reserved. 4.106.4.2.2 Multifamily dwellings, hotels and motels 1. EV ready parking spaces with receptacles. a. Hotels and motels. Forty (40) percent of the total number of parking spaces shall be equipped with low power Level 2 EV charging receptacles. b. Multifamily parking facilities. Forty (40) percent of the total number of parking spaces shall be equipped with low power Level 2 EV charging receptacles. EV charging receptacles required by this section shall be located in at least one assigned parking space per dwelling unit where assigned parking is provided but need not exceed forty (40) percent of the total number of assigned parking spaces provided on the site. Exception: Areas of parking facilities served by parking lifts, including but not limited to automated mechanical-access open parking garages as defined in the California Building Code; or parking facilities otherwise incapable of supporting electric vehicle charging. c. Receptacle power source. EV charging receptacles in multifamily parking facilities shall be provided with a dedicated branch circuit connected to the dwelling unit’s electrical panel, unless determined as infeasible by the project builder or designer and subject to concurrence of the local enforcing agency. Exception: Areas of parking facilities served by parking lifts, including but not limited to automated mechanical-access open parking garages as defined in the California Building Code; or parking facilities otherwise incapable of supporting electric vehicle charging. d. Receptacle configurations. 208/240V EV charging receptacles shall comply with one of the following configurations: 1. For 20-ampere receptacles, NEMA 6-20R 2. For 30-ampere receptacles, NEMA 14-30R 3. For 50-ampere receptacles, NEMA 14-50R 2. EV ready parking spaces with EV chargers. a. Hotels and motels. Ten (10) percent of the total number of parking spaces shall be equipped with Level 2 EV chargers. At least fifty (50) percent of the required EV chargers shall be equipped with J1772 connectors. b. Multifamily parking facilities. Ten (10) percent of the total number of parking spaces shall be equipped with Level 2 EV chargers. At least fifty (50) percent of the required EV chargers shall be equipped with J1772 connectors. Where common use parking or unassigned parking is provided, EV chargers shall be located in common use or unassigned parking areas and shall be available for use by all residents or guests. Where low power Level 2 EV charging receptacles or Level 2 EV chargers are installed beyond the minimum required, an automatic load management system (ALMS) may be used to reduce the maximum required electrical capacity to each space served by the ALMS. The electrical system and any on-site distribution transformers shall have sufficient capacity to deliver at least 3.3 kW simultaneously to each EV charging station (EVCS) served by the ALMS. The branch circuit shall have a minimum capacity of 40 amperes, and installed EV chargers shall have a capacity of not less than 30 amperes. 4.106.4.2.2.1 Electric vehicle charging stations (EVCS). Electric vehicle charging stations required by Section 4.106.4.2.2, Item 2, with EV chargers installed shall comply with Section 4.106.4.2.2.1.1. Exception: Electric vehicle charging stations serving public accommodations, public housing, motels and hotels shall not be required to comply with this section. See California Building Code, Chapter 11B, for applicable requirements. 4.106.4.2.2.1.1 Electric vehicle charging stations (EVCS) spaces with EV chargers installed; dimensions and location. EVCS spaces shall be designed to comply with the following: 1. The minimum length of each EVCS space shall be 18 feet (5486 mm). 2. The minimum width of each EVCS space shall be 9 feet (2743 mm). 3. One in every 25 EVCS spaces, but not less than one, shall also have an 8-foot (2438 mm) wide minimum aisle. A 5-foot (1524 mm) wide minimum aisle shall be permitted provided the minimum width of the EVCS space is 12 feet (3658 mm). Surface slope for this EVCS space and the aisle shall not exceed 1 unit vertical in 48 units horizontal (2.083 percent slope) in any direction. These EVCS spaces shall also comply with at least one of the following: a. The EVCS space shall be located adjacent to an accessible parking space meeting the requirements of the California Building Code, Chapter 11A, to allow use of the EV charger from the accessible parking space. b. The EVCS space shall be located on an accessible route, as defined in the California Building Code, Chapter 2, to the building. Exception: Electric vehicle charging stations designed and constructed in compliance with the California Building Code, Chapter 11B, are not required to comply with Section 4.106.4.2.2.1.1. 4.106.4.2.2.1.2 Accessible electric vehicle charging station spaces. In addition to the requirements in Section 4.106.4.2.2.1.1, all EV chargers, where installed, shall comply with the accessibility provisions for EV chargers in the California Building Code, Chapter 11B. EV ready spaces and EVCS in multifamily developments shall comply with California Building Code, Chapter 11A, Section 1109A. 4.106.4.2.3 Reserved. 4.106.4.2.4 Reserved. 4.106.4.2.5 Electric vehicle ready space signage. Electric vehicle ready spaces shall be identified by signage or pavement markings, in compliance with Caltrans Traffic Operations Policy Directive 13-01 (Zero Emission Vehicle Signs and Pavement Markings) or its successor(s). 4.106.4.3 Electric vehicle charging for additions and alterations of parking facilities serving existing multi-family buildings. Where new parking facilities are added, or electrical systems or lighting of existing parking facilities are added or altered and the work requires a building permit, ten (10) percent of the total number of parking spaces added or altered shall be EV capable spaces to support future Level 2 electric vehicle supply equipment. The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging purposes as “EV CAPABLE.” Notes: 1.Construction documents are intended to demonstrate the project’s capability and capacity for facilitating future EV charging. 2.There is no requirement for EV spaces to be constructed or available until EV chargers are installed for use. SECTION 4.501 GENERAL 4.501.1 Scope The provisions of this chapter shall outline means of reducing the quality of air contaminants that are odorous, irritating and/or harmful to the comfort and well being of a building's installers, occupants and neighbors. SECTION 4.502 DEFINITIONS 5.102.1 DEFINITIONS The following terms are defined in Chapter 2 (and are included here for reference) AGRIFIBER PRODUCTS. Agrifiber products include wheatboard, strawboard, panel substrates and door cores, not including furniture, fixtures and equipment (FF&E) not considered base building elements. COMPOSITE WOOD PRODUCTS. Composite wood products include hardwood plywood, particleboard and medium density fiberboard. "Composite wood products" does not include hardboard, structural plywood, structural panels, structural composite lumber, oriented strand board, glued laminated timber, prefabricated wood I-joists or finger-jointed lumber, all as specified in California Code of regulations (CCR), title 17, Section 93120.1. DIRECT-VENT APPLIANCE. A fuel-burning appliance with a sealed combustion system that draws all air for combustion from the outside atmosphere and discharges all flue gases to the outside atmosphere. DISCLAIMER:THIS DOCUMENT IS PROVIDED AND INTENDED TO BE USED AS A MEANS TO INDICATE AREAS OF COMPLIANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS (CALGREEN) CODE. DUE TO THE VARIABLES BETWEEN BUILDING DEPARTMENT JURISDICTIONS, THIS CHECKLIST IS TO BE USED ON AN INDIVIDUAL PROJECT BASIS AND MAY BE MODIFIED BY THE END USER TO MEET THOSE INDIVIDUAL NEEDS. THE END USER ASSUMES ALL RESPONSIBILITY ASSOCIATED WITH THE USE OF THIS DOCUMENT, INCLUDING VERIFICATION WITH THE FULL CODE. Y N/AY N/AY N/AY N/A RESPON. PARTY RESPON. PARTY RESPON. PARTY RESPON. PARTY 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE RESIDENTIAL MANDATORY MEASURES, SHEET 1 (July 2024 Supplement)Y = YES N/A = NOT APPLICABLE RESPON. PARTY = RESPONSIBLE PARTY (ie: ARCHITECT, ENGINEER, OWNER, CONTRACTOR, INSPECTOR ETC.) 4.201 GENERAL 4.201.1 SCOPE. For the purposes of mandatory energy efficiency standards in this code, the California Energy Commission will continue to adopt mandatory standards. DIVISION 4.2 ENERGY EFFICIENCY TABLE H-2 STANDARDS FOR COMMERCIAL PRE-RINSE SPRAY VALUES MANUFACTURED ON OR AFTER JANUARY 28, 2019 PRODUCT CLASS [spray force in ounce force (ozf)]MAXIMUM FLOW RATE (gpm) Product Class 1 (≤1.00 Product Class 2 (> 5.0 ozf and ≤1.20 Product Class 3 (> 8.0 ozf)1.28 T-3 15 2 9 W S A I N T A N N E P L U N I T 2 SA N T A A N A C A , 9 2 7 0 4 Y Y Y Y MAXIMUM INCREMENTAL REACTIVITY (MIR). The maximum change in weight of ozone formed by adding a compound to the "Base Reactive Organic Gas (ROG) Mixture" per weight of compound added, expressed to hundredths of a gram (g O³/g ROC). Note: MIR values for individual compounds and hydrocarbon solvents are specified in CCR, Title 17, Sections 94700 and 94701. MOISTURE CONTENT. The weight of the water in wood expressed in percentage of the weight of the oven-dry wood. PRODUCT-WEIGHTED MIR (PWMIR). The sum of all weighted-MIR for all ingredients in a product subject to this article. The PWMIR is the total product reactivity expressed to hundredths of a gram of ozone formed per gram of product (excluding container and packaging). Note: PWMIR is calculated according to equations found in CCR, Title 17, Section 94521 (a). REACTIVE ORGANIC COMPOUND (ROC). Any compound that has the potential, once emitted, to contribute to ozone formation in the troposphere. VOC. A volatile organic compound (VOC) broadly defined as a chemical compound based on carbon chains or rings with vapor pressures greater than 0.1 millimeters of mercury at room temperature. These compounds typically contain hydrogen and may contain oxygen, nitrogen and other elements. See CCR Title 17, Section 94508(a). 4.503 FIREPLACES 4.503.1 GENERAL. Any installed gas fireplace shall be a direct-vent sealed-combustion type. Any installed woodstove or pellet stove shall comply with U.S. EPA New Source Performance Standards (NSPS) emission limits as applicable, and shall have a permanent label indicating they are certified to meet the emission limits. Woodstoves, pellet stoves and fireplaces shall also comply with applicable local ordinances. 4.504 POLLUTANT CONTROL 4.504.1 COVERING OF DUCT OPENINGS & PROTECTION OF MECHANICAL EQUIPMENT DURING CONSTRUCTION. At the time of rough installation, during storage on the construction site and until final startup of the heating, cooling and ventilating equipment, all duct and other related air distribution component openings shall be covered with tape, plastic, sheet metal or other methods acceptable to the enforcing agency to reduce the amount of water, dust or debris which may enter the system. 4.504.2 FINISH MATERIAL POLLUTANT CONTROL. Finish materials shall comply with this section. 4.504.2.1 Adhesives, Sealants and Caulks. Adhesives, sealant and caulks used on the project shall meet the requirements of the following standards unless more stringent local or regional air pollution or air quality management district rules apply: 1. Adhesives, adhesive bonding primers, adhesive primers, sealants, sealant primers and caulks shall comply with local or regional air pollution control or air quality management district rules where applicable or SCAQMD Rule 1168 VOC limits, as shown in Table 4.504.1 or 4.504.2, as applicable. Such products also shall comply with the Rule 1168 prohibition on the use of certain toxic compounds (chloroform, ethylene dichloride, methylene chloride, perchloroethylene and tricloroethylene), except for aerosol products, as specified in Subsection 2 below. 2. Aerosol adhesives, and smaller unit sizes of adhesives, and sealant or caulking compounds (in units of product, less packaging, which do not weigh more than 1 pound and do not consist of more than 16 fluid ounces) shall comply with statewide VOC standards and other requirements, including prohibitions on use of certain toxic compounds, of California Code of Regulations, Title 17, commencing with section 94507. 4.504.2.2 Paints and Coatings. Architectural paints and coatings shall comply with VOC limits in Table 1 of the ARB Architectural Suggested Control Measure, as shown in Table 4.504.3, unless more stringent local limits apply. The VOC content limit for coatings that do not meet the definitions for the specialty coatings categories listed in Table 4.504.3 shall be determined by classifying the coating as a Flat, Nonflat or Nonflat-High Gloss coating, based on its gloss, as defined in subsections 4.21, 4.36, and 4.37 of the 2007 California Air Resources Board, Suggested Control Measure, and the corresponding Flat, Nonflat or Nonflat-High Gloss VOC limit in Table 4.504.3 shall apply. 4.504.2.3 Aerosol Paints and Coatings. Aerosol paints and coatings shall meet the Product-weighted MIR Limits for ROC in Section 94522(a)(2) and other requirements, including prohibitions on use of certain toxic compounds and ozone depleting substances, in Sections 94522(e)(1) and (f)(1) of California Code of Regulations, Title 17, commencing with Section 94520; and in areas under the jurisdiction of the Bay Area Air Quality Management District additionally comply with the percent VOC by weight of product limits of Regulation 8, Rule 49. 4.504.2.4 Verification. Verification of compliance with this section shall be provided at the request of the enforcing agency. Documentation may include, but is not limited to, the following: 1. Manufacturer's product specification. 2. Field verification of on-site product containers. CHAPTER 7 INSTALLER & SPECIAL INSPECTOR QUALIFICATIONS 702 QUALIFICATIONS 702.1 INSTALLER TRAINING. HVAC system installers shall be trained and certified in the proper installation of HVAC systems including ducts and equipment by a nationally or regionally recognized training or certification program. Uncertified persons may perform HVAC installations when under the direct supervision and responsibility of a person trained and certified to install HVAC systems or contractor licensed to install HVAC systems. Examples of acceptable HVAC training and certification programs include but are not limited to the following: 1. State certified apprenticeship programs. 2. Public utility training programs. 3. Training programs sponsored by trade, labor or statewide energy consulting or verification organizations. 4. Programs sponsored by manufacturing organizations. 5. Other programs acceptable to the enforcing agency. 702.2 SPECIAL INSPECTION [HCD]. When required by the enforcing agency, the owner or the responsible entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition to other certifications or qualifications acceptable to the enforcing agency, the following certifications or education may be considered by the enforcing agency when evaluating the qualifications of a special inspector: 1. Certification by a national or regional green building program or standard publisher. 2. Certification by a statewide energy consulting or verification organization, such as HERS raters, building performance contractors, and home energy auditors. 3. Successful completion of a third party apprentice training program in the appropriate trade. 4. Other programs acceptable to the enforcing agency. Notes: 1. Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code. 2. HERS raters are special inspectors certified by the California Energy Commission (CEC) to rate homes in California according to the Home Energy Rating System (HERS). [BSC] When required by the enforcing agency, the owner or the responsible entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition, the special inspector shall have a certification from a recognized state, national or international association, as determined by the local agency. The area of certification shall be closely related to the primary job function, as determined by the local agency. Note: Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code. 703 VERIFICATIONS 703.1 DOCUMENTATION. Documentation used to show compliance with this code shall include but is not limited to, construction documents, plans, specifications, builder or installer certification, inspection reports, or other methods acceptable to the enforcing agency which demonstrate substantial conformance. When specific documentation or special inspection is necessary to verify compliance, that method of compliance will be specified in the appropriate section or identified applicable checklist. 4.505 INTERIOR MOISTURE CONTROL 4.505.1 General. Buildings shall meet or exceed the provisions of the California Building Standards Code. 4.505.2 CONCRETE SLAB FOUNDATIONS. Concrete slab foundations required to have a vapor retarder by California Building Code, Chapter 19, or concrete slab-on-ground floors required to have a vapor retarder by the California Residential Code, Chapter 5, shall also comply with this section. 4.505.2.1 Capillary break. A capillary break shall be installed in compliance with at least one of the following: 1. A 4-inch (101.6 mm) thick base of 1/2 inch (12.7mm) or larger clean aggregate shall be provided with a vapor barrier in direct contact with concrete and a concrete mix design, which will address bleeding, shrinkage, and curling, shall be used. For additional information, see American Concrete Institute, ACI 302.2R-06. 2. Other equivalent methods approved by the enforcing agency. 3. A slab design specified by a licensed design professional. 4.505.3 MOISTURE CONTENT OF BUILDING MATERIALS. Building materials with visible signs of water damage shall not be installed. Wall and floor framing shall not be enclosed when the framing members exceed 19 percent moisture content. Moisture content shall be verified in compliance with the following: 1. Moisture content shall be determined with either a probe-type or contact-type moisture meter.Equivalent moisture verification methods may be approved by the enforcing agency and shall satisfy requirements found in Section 101.8 of this code. 2. Moisture readings shall be taken at a point 2 feet (610 mm) to 4 feet (1219 mm) from the grade stamped end of each piece verified. 3. At least three random moisture readings shall be performed on wall and floor framing with documentation acceptable to the enforcing agency provided at the time of approval to enclose the wall and floor framing. Insulation products which are visibly wet or have a high moisture content shall be replaced or allowed to dry prior to enclosure in wall or floor cavities. Wet-applied insulation products shall follow the manufacturers' drying recommendations prior to enclosure. 4.506 INDOOR AIR QUALITY AND EXHAUST 4.506.1 Bathroom exhaust fans. Each bathroom shall be mechanically ventilated and shall comply with the following: 1. Fans shall be ENERGY STAR compliant and be ducted to terminate outside the building. 2. Unless functioning as a component of a whole house ventilation system, fans must be controlled by a humidity control. a. Humidity controls shall be capable of adjustment between a relative humidity range less than or equal to 50% to a maximum of 80%. A humidity control may utilize manual or automatic means of adjustment. b. A humidity control may be a separate component to the exhaust fan and is not required to be integral (i.e., built-in) Notes: 1. For the purposes of this section, a bathroom is a room which contains a bathtub, shower or tub/shower combination. 2. Lighting integral to bathroom exhaust fans shall comply with the California Energy Code. 4.507 ENVIRONMENTAL COMFORT 4.507.2 HEATING AND AIR-CONDITIONING SYSTEM DESIGN. Heating and air conditioning systems shall be sized, designed and have their equipment selected using the following methods: 1. The heat loss and heat gain is established according to ANSI/ACCA 2 Manual J - 2011 (Residential Load Calculation), ASHRAE handbooks or other equivalent design software or methods. 2. Duct systems are sized according to ANSI/ACCA 1 Manual D - 2014 (Residential Duct Systems), ASHRAE handbooks or other equivalent design software or methods. 3. Select heating and cooling equipment according to ANSI/ACCA 3 Manual S - 2014 (Residential Equipment Selection), or other equivalent design software or methods. Exception: Use of alternate design temperatures necessary to ensure the system functions are acceptable. TABLE 4.504.1 - ADHESIVE VOC LIMIT1,2 (Less Water and Less Exempt Compounds in Grams per Liter) ARCHITECTURAL APPLICATIONS VOC LIMIT INDOOR CARPET ADHESIVES 50 CARPET PAD ADHESIVES 50 OUTDOOR CARPET ADHESIVES 150 WOOD FLOORING ADHESIVES 100 RUBBER FLOOR ADHESIVES 60 SUBFLOOR ADHESIVES 50 CERAMIC TILE ADHESIVES 65 VCT & ASPHALT TILE ADHESIVES 50 DRYWALL & PANEL ADHESIVES 50 COVE BASE ADHESIVES 50 MULTIPURPOSE CONSTRUCTION ADHESIVE 70 STRUCTURAL GLAZING ADHESIVES 100 SINGLE-PLY ROOF MEMBRANE ADHESIVES 250 OTHER ADHESIVES NOT LISTED 50 SPECIALTY APPLICATIONS PVC WELDING 510 CPVC WELDING 490 ABS WELDING 325 PLASTIC CEMENT WELDING 250 ADHESIVE PRIMER FOR PLASTIC 550 CONTACT ADHESIVE 80 SPECIAL PURPOSE CONTACT ADHESIVE 250 STRUCTURAL WOOD MEMBER ADHESIVE 140 TOP & TRIM ADHESIVE 250 SUBSTRATE SPECIFIC APPLICATIONS METAL TO METAL 30 PLASTIC FOAMS 50 POROUS MATERIAL (EXCEPT WOOD)50 WOOD 30 FIBERGLASS 80 1. IF AN ADHESIVE IS USED TO BOND DISSIMILAR SUBSTRATES TOGETHER, THE ADHESIVE WITH THE HIGHEST VOC CONTENT SHALL BE ALLOWED. 2. FOR ADDITIONAL INFORMATION REGARDING METHODS TO MEASURE THE VOC CONTENT SPECIFIED IN THIS TABLE, SEE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168. TABLE 4.504.2 - SEALANT VOC LIMIT (Less Water and Less Exempt Compounds in Grams per Liter) SEALANTS VOC LIMIT ARCHITECTURAL 250 MARINE DECK 760 NONMEMBRANE ROOF 300 ROADWAY 250 SINGLE-PLY ROOF MEMBRANE 450 OTHER 420 SEALANT PRIMERS ARCHITECTURAL NON-POROUS 250 POROUS 775 MODIFIED BITUMINOUS 500 MARINE DECK 760 OTHER 750 TABLE 4.504.5 - FORMALDEHYDE LIMITS1 MAXIMUM FORMALDEHYDE EMISSIONS IN PARTS PER MILLION PRODUCT CURRENT LIMIT HARDWOOD PLYWOOD VENEER CORE 0.05 HARDWOOD PLYWOOD COMPOSITE CORE 0.05 PARTICLE BOARD 0.09 MEDIUM DENSITY FIBERBOARD 0.11 THIN MEDIUM DENSITY FIBERBOARD2 0.13 1. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIF. AIR RESOURCES BOARD, AIR TOXICS CONTROL MEASURE FOR COMPOSITE WOOD AS TESTED IN ACCORDANCE WITH ASTM E 1333. FOR ADDITIONAL INFORMATION, SEE CALIF. CODE OF REGULATIONS, TITLE 17, SECTIONS 93120 THROUGH 93120.12. 2. THIN MEDIUM DENSITY FIBERBOARD HAS A MAXIMUM THICKNESS OF 5/16" (8 MM). TABLE 4.504.3 - VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS2,3 GRAMS OF VOC PER LITER OF COATING, LESS WATER & LESS EXEMPT COMPOUNDS COATING CATEGORY VOC LIMIT FLAT COATINGS 50 NON-FLAT COATINGS 100 NONFLAT-HIGH GLOSS COATINGS 150 SPECIALTY COATINGS ALUMINUM ROOF COATINGS 400 BASEMENT SPECIALTY COATINGS 400 BITUMINOUS ROOF COATINGS 50 BITUMINOUS ROOF PRIMERS 350 BOND BREAKERS 350 CONCRETE CURING COMPOUNDS 350 CONCRETE/MASONRY SEALERS 100 DRIVEWAY SEALERS 50 DRY FOG COATINGS 150 FAUX FINISHING COATINGS 350 FIRE RESISTIVE COATINGS 350 FLOOR COATINGS 100 FORM-RELEASE COMPOUNDS 250 GRAPHIC ARTS COATINGS (SIGN PAINTS)500 HIGH TEMPERATURE COATINGS 420 INDUSTRIAL MAINTENANCE COATINGS 250 LOW SOLIDS COATINGS1 120 MAGNESITE CEMENT COATINGS 450 MASTIC TEXTURE COATINGS 100 METALLIC PIGMENTED COATINGS 500 MULTICOLOR COATINGS 250 PRETREATMENT WASH PRIMERS 420 PRIMERS, SEALERS, & UNDERCOATERS 100 REACTIVE PENETRATING SEALERS 350 RECYCLED COATINGS 250 ROOF COATINGS 50 RUST PREVENTATIVE COATINGS 250 SHELLACS CLEAR 730 OPAQUE 550 SPECIALTY PRIMERS, SEALERS & UNDERCOATERS 100 STAINS 250 STONE CONSOLIDANTS 450 SWIMMING POOL COATINGS 340 TRAFFIC MARKING COATINGS 100 TUB & TILE REFINISH COATINGS 420 WATERPROOFING MEMBRANES 250 WOOD COATINGS 275 WOOD PRESERVATIVES 350 ZINC-RICH PRIMERS 340 1. GRAMS OF VOC PER LITER OF COATING, INCLUDING WATER & EXEMPT COMPOUNDS 2. THE SPECIFIED LIMITS REMAIN IN EFFECT UNLESS REVISED LIMITS ARE LISTED IN SUBSEQUENT COLUMNS IN THE TABLE. 3. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR RESOURCES BOARD, ARCHITECTURAL COATINGS SUGGESTED CONTROL MEASURE, FEB. 1, 2008. MORE INFORMATION IS AVAILABLE FROM THE AIR RESOURCES BOARD. DIVISION 4.5 ENVIRONMENTAL QUALITY (continued) 4.504.3 CARPET SYSTEMS. All carpet installed in the building interior shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.3.1 Carpet cushion. All carpet cushion installed in the building interior shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.3.2 Carpet adhesive. All carpet adhesive shall meet the requirements of Table 4.504.1. 4.504.4 RESILIENT FLOORING SYSTEMS. Where resilient flooring is installed , at least 80% of floor area receiving resilient flooring shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health's website for certification programs and testing labs. hhtps://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.5 COMPOSITE WOOD PRODUCTS. Hardwood plywood, particleboard and medium density fiberboard composite wood products used on the interior or exterior of the buildings shall meet the requirements for formaldehyde as specified in ARB's Air Toxics Control Measure for Composite Wood (17 CCR 93120 et seq.), by or before the dates specified in those sections, as shown in Table 4.504.5 4.504.5.1 Documentation. Verification of compliance with this section shall be provided as requested by the enforcing agency. Documentation shall include at least one of the following: 1. Product certifications and specifications. 2. Chain of custody certifications. 3. Product labeled and invoiced as meeting the Composite Wood Products regulation (see CCR, Title 17, Section 93120, et seq.). 4. Exterior grade products marked as meeting the PS-1 or PS-2 standards of the Engineered Wood Association, the Australian AS/NZS 2269, European 636 3S standards, and Canadian CSA 0121, CSA 0151, CSA 0153 and CSA 0325 standards. 5. Other methods acceptable to the enforcing agency. DISCLAIMER:THIS DOCUMENT IS PROVIDED AND INTENDED TO BE USED AS A MEANS TO INDICATE AREAS OF COMPLIANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS (CALGREEN) CODE. DUE TO THE VARIABLES BETWEEN BUILDING DEPARTMENT JURISDICTIONS, THIS CHECKLIST IS TO BE USED ON AN INDIVIDUAL PROJECT BASIS AND MAY BE MODIFIED BY THE END USER TO MEET THOSE INDIVIDUAL NEEDS. THE END USER ASSUMES ALL RESPONSIBILITY ASSOCIATED WITH THE USE OF THIS DOCUMENT, INCLUDING VERIFICATION WITH THE FULL CODE. Y N/AY N/AY N/AY N/A RESPON. PARTY RESPON. PARTY RESPON. PARTY RESPON. PARTY 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE RESIDENTIAL MANDATORY MEASURES, SHEET 2 (July 2024 Supplement)Y = YES N/A = NOT APPLICABLE RESPON. PARTY = RESPONSIBLE PARTY (ie: ARCHITECT, ENGINEER, OWNER, CONTRACTOR, INSPECTOR ETC.) 15 2 9 W S A I N T A N N E P L U N I T 2 SA N T A A N A C A , 9 2 7 0 4 T-4 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y structural calculations for 1012 N KEMP STREET new adu above (e)garage 1012 N KEMP STREET ANAHEIM, CA 92801. 09-JUNE-25 CE JOB NO. : 25-181 S T R U C T U R A L 3 2 4 E S O U T H S T , L O N G B E A C H , C A L I F O R N I A 9 0 8 0 5 T : 5 6 2 . 9 6 1 . 5 6 0 0 W W W . C A S T I L L O E N G I N E E R I N G . C O M 1 ARCHITECT CASTILLO ENGINEERING, INC.JOB 1205 Pine Avenue, Suite 201 Long Beach, CA 90813 ENGR. MC JOB NO. SHEET NO. DESIGN CRITERIA 1 Soil supporting footings is natural grade or engineered fill. 2 Soil allowable bearing pressure used in design_______________________________ 3 Footing shall extend_____ minimum into undisturbed soil or_____ below finish grade whichever is lower. 4 All concrete shall develop a minimum compressive strength of 2500 psi in 28 days. 5 Reinforcing steel shall conform to ASTM 615, Grade 60. 6 Structural steel shall conform to the following: Wide flange shapes ASTM A992 TS shapes ASTM A500, Grade B Pipe shapes ASTM A53 , Grade B Other rolled shapes, Bars and plates ASTM A36 7 Structural steel shall be fabricated in a shop of an approved fabricator. 8 All welding shall be done by Certified Welders. 9 Concrete Block shall conform to ASTM C90, Grade N-1. 10 Grout shall develop 2000 psi in 28 days. 11 Mortar shall be Type S and develop 1800 psi in 28 days. 12 All lumber shall be grade marked Douglas Fir. (Grading rule No. 17) Light Framing Construction Joist & Planks No. 2 Beams & Stringers No. 1 Posts & Timbers No. 1 13 Glue Laminated Timbers shall be combination No. 24F-V8. 14 Plywood shall conform to PS 1-95, Structural 1. 15 All material and workmanship shall conform to the requirements of 2019 California Building Code. 2 ARCHITECT ENGR. DATE: CASTILLO ENGINEERING, INC. 1205 Pine Avenue, Suit.e 201 Long Beach, CA 80813 SHEET NO. D □UGLAS F"IR.-LAR.CH DESIGN VALUES DESIGNATION GRADE FB FT Fcperp. LIGHT FRAMING CONSTRUCTION 1000 650 625 2" TO 4" THICK 2"TO4' WIDE JOIST & PLANKS NO. 2 900 575 625 2" TO 4" THICK 6"&WIDER POST & TIMBER NO.1 1200 825 625 5x5 AND LARGER WIDTH NOT MORE THAN 2" GREATER THAN THICKNESS BEAM & STRINGER NO.1 1350 675 625 5" & THICKER WIDTH MORE THAN 2" GREATER THAN THICKNESS GLU-LAM BEAMS COMBINATION 2400 1100 650 NO. 24F-V8 Y-DIR 1450 1100 560 ( 1 )THE ABOVE VALUES ARE TAKEN FROM THE NOS. (2)USE STANDARD GRADING RULE NO. 1 7. Fe Fv 1650 180 1350 180 1000 170 925 170 1650 265 1650 230 E E MIN 1,500,000 550,000 1,600,000 580,000 1,600,000 580,000 1,600,000 580,000 1,800,000 930,000 1,600,000 830,000 3 PROJECT:CASTILLO ENGINEERING 324 E South St, Long Beach, CA 90805 37683.00 Wood :Douglas-Fir/Larch Cr = 1.15 (repetitive member factor)Fv =180 psi (for Light Framing and Joists & Planks) E = 1,500,000 psi (Const Light Framing)Fv =170 psi (for Beams & Stringers and Posts & Timbers) E = 1,600,000 psi (#2 Joists & Planks, #1 Beams & Stringers, #1 Posts & Timbers) FLOO ROOF MEMBER:SIZE:(35 PCF)PROPERTIES:BENDING STRESS:1.00 (k-ft & k)Cd =1.00 (k-ft & k)Cd =1.25 Nominal Grade Type B (in)D (in)PLF (in^2)S(in^3)I(in^4)Fb(psi)CF Fb x CF max Mmax Mmax(rep)max Mmax Mmax(rep) 2x4 Const. LF 1.5 3.50 1.3 5.3 3.1 5.4 1000 1.00 1000 0.63 0.26 0.29 0.79 0.32 0.37 2x6 #2 JP 1.5 5.50 2.0 8.3 7.6 20.8 900 1.30 1170 0.99 0.74 0.85 1.24 0.92 1.06 2x8 #2 JP 1.5 7.25 2.6 10.9 13.1 47.6 900 1.20 1080 1.31 1.18 1.36 1.63 1.48 1.70 2x10 #2 JP 1.5 9.25 3.4 13.9 21.4 98.9 900 1.10 990 1.67 1.76 2.03 2.08 2.21 2.54 2x12 #2 JP 1.5 11.25 4.1 16.9 31.6 178.0 900 1.00 900 2.03 2.37 2.73 2.53 2.97 3.41 2x14 #2 JP 1.5 13.25 4.8 19.9 43.9 290.8 900 0.90 810 2.39 2.96 3.41 2.98 3.70 4.26 4x4 Const LF 3.5 3.50 3.0 12.3 7.1 12.5 1000 1.00 1000 1.47 0.60 0.68 1.84 0.74 0.86 4x6 #2 JP 3.5 5.50 4.7 19.3 17.6 48.5 900 1.30 1170 2.31 1.72 1.98 2.89 2.15 2.47 4x8 #2 JP 3.5 7.25 6.2 25.4 30.7 111.1 900 1.30 1170 3.05 2.99 3.44 3.81 3.74 4.30 4x10 #2 JP 3.5 9.25 7.9 32.4 49.9 230.8 900 1.20 1080 3.89 4.49 5.17 4.86 5.62 6.46 4x12 #2 JP 3.5 11.25 9.6 39.4 73.8 415.3 900 1.10 990 4.73 6.09 7.00 5.91 7.61 8.76 4x14 #2 JP 3.5 13.25 11.3 46.4 102.4 678.5 900 1.00 900 5.57 7.68 8.83 6.96 9.60 11.0 6x4 #2 JP 5.5 3.50 4.7 19.3 11.2 19.7 900 1.00 900 2.31 0.84 2.89 1.05 6x6 #1 PT 5.5 5.50 7.4 30.3 27.7 76.3 1200 1.00 1200 3.43 2.77 4.29 3.47 6x8 #1 PT 5.5 7.50 10.0 41.3 51.6 193.4 1200 1.00 1200 4.68 5.16 5.84 6.45 6x10 #1 BS 5.5 9.50 12.7 52.3 82.7 393.0 1350 1.00 1350 5.92 9.31 7.40 11.6 6x12 #1 BS 5.5 11.50 15.4 63.3 121.2 697.1 1350 1.00 1350 7.17 13.6 8.96 17.0 6x14 #1 BS 5.5 13.50 18.0 74.3 167.1 1127.7 1350 0.99 1332 8.42 18.6 10.5 23.2 4 5 6 7 8 CASTILLO ENGINEERING, INC 1147 E. Market Street Long Beach, CA 90805 ROOF LOADS composite shingles 2.5 psf re-roof 2.0 psf 1/2" plywwod 1.5 psf rafters 4.0 psf insulation 0.5 psf Ceiling 3.0 psf beams/headers 1.0 psf MP&E/ misc.0.5 psf D=15.0 psf Lr= 20.0 psf REDUCIBLE FLOOR LOADS flooring 1.0 psf 3/4" plywood 2.3 psf joist 3.0 psf ceiling 4.0 psf beams/headers 2.0 psf MP&E/ misc.2.7 psf D=15.0 psf L= 40.0 psf EXTERIOR WALL LOADS 7/8" stucco 10.0 psf 1/2" plywood 1.5 psf 2x6 studs at 16"oc 1.5 psf insulation 0.5 psf 1/2" gyp board 2.3 psf MP&E/ misc.0.2 psf D=16.0 psf INTERIOR WALL LOADS 1/2" gyp board 2.3 psf 1/2" plywood 1.5 psf 2x6 studs at 16"oc 1.5 psf insulation 0.5 psf 1/2" gyp board 2.3 psf MP&E/ misc.1.9 psf D=10.0 psf 9 10 11 ARCHITECT JOB 1205 Pine Avenue, Suite 201 Long Beach, CA 90813 ENGR. MC DATE:JOB NO. SHEET NO. CASTILLO ENGINEERING, INC. REMARKS 4x4 4x4 4X4 4X6 4X67.15 10.83 ALLOWABLE 75% 2.31 3.42 4.23 6X6HDU14 3.075 4.565 5.645 6.970 9.535 14.445 5.23 HDU5 HDU8 HDU11 HOLDOWNS HDU2 HDU4 HD ALLOWABLE UPLIFT 12 13 CE E n g i n e e r i n g S o f t w a r e v 1 . 0 PR O J E C T : == T Y P I C A L S Q U A R E P A D F O O T I N G D E S I G N T A B L E = = (2 / 9 9 ) Ba r # So i l B e a r i n g P r e s s u r e : Mi s c e l l a n e o u s : 3 0 . 1 1 q = 15 0 0 ps f c o l u m n f o o t p r i n t = 4 in 4 0 . 2 0 (f o r s e l e c t i o n o f s t e e l s p a c i n g v s . s i z e o n l y ) 6 0 . 4 4 Ma t e r i a l S t r e n g t h s : 7 0 . 6 0 co n c r e t e = 25 0 0 ps i No t e s : 8 0 . 7 8 10 1 . 2 3 11 1 . 5 6 Ma r k : Si z e T h i c k (f t ) - S Q . ( i n ) ( k ) ( i n ) 1. 5 1 2 3. 0 4 8 0 . 0 1 2 . 2 Y 2 . 7 6 5 . 3 Y 7 0 . 0 2 0 . 0 2 0 . 7 2 0 . 3 9 0 . 3 9 2 # 4 2. 0 1 2 5. 4 0 8 0 . 7 1 6 . 3 Y 6 . 5 6 5 . 3 Y 1 8 0 . 0 5 0 . 0 4 0 . 9 6 0 . 5 2 0 . 5 2 3 # 4 2. 5 1 2 8. 4 4 8 2 . 3 2 0 . 4 Y 1 1 . 3 6 5 . 3 Y 3 8 0 . 0 8 0 . 0 9 1 . 2 0 0 . 6 5 0 . 6 5 4 # 4 3. 0 1 2 12 . 2 8 4 . 3 2 4 . 5 Y 1 7 . 3 6 5 . 3 Y 6 9 0 . 1 3 0 . 1 6 1 . 4 4 0 . 7 8 0 . 7 8 4 # 4 3. 5 1 2 16 . 5 8 6 . 9 2 8 . 6 Y 2 4 . 3 6 5 . 3 Y 1 1 4 0 . 1 8 0 . 2 7 1 . 6 8 0 . 9 1 0 . 9 1 5 # 4 4. 0 1 2 21 . 6 8 1 0 . 1 3 2 . 6 Y 3 2 . 4 6 5 . 3 Y 1 7 4 0 . 2 4 0 . 4 1 1 . 9 2 1 . 0 4 1 . 0 4 6 # 4 4. 5 1 2 27 . 3 8 1 3 . 8 3 6 . 7 Y 4 1 . 6 6 5 . 3 Y 2 5 3 0 . 3 1 0 . 6 0 2 . 1 6 1 . 1 7 1 . 1 7 4 # 5 5. 0 1 2 33 . 8 8 1 8 . 0 4 0 . 8 Y 5 1 . 8 6 5 . 3 Y 3 5 3 0 . 3 9 0 . 8 4 2 . 4 0 1 . 3 0 1 . 3 0 5 # 5 5. 5 1 2 40 . 8 8 2 2 . 8 4 4 . 9 Y 6 3 . 2 6 5 . 3 Y 4 7 6 0 . 4 9 1 . 1 4 2 . 6 4 1 . 4 3 1 . 5 1 5 # 5 6. 0 1 5 47 . 3 1 1 2 4 . 2 6 7 . 3 Y 7 2 . 3 1 1 2 . 2 Y 6 0 7 0 . 4 1 1 . 0 4 3 . 6 0 1 . 9 4 1 . 9 4 7 # 5 14 C.J. C. J . ROOF KEYPLAN RJ3 RJ1 RJ2 RJ2 B1 H1 H1 H1 H2 H2 H3 H3 H5 H4 15 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet Tag Beam 5 L =9.75 ft Member=2x6 A =8.25 in^2 S =7.6 in^3 No. of members=1 I =20.8 in^4 CD=1.25 E =1,600,000 psi CF=1.30 Va =0.990 kips CV=1.00 Ma =0.567 k-ft Cr=1.15 Total Load L/n=180 Live Load L/n=240 L=9.75 ft 0.23 0.23 Uniform load (W1) D L Trib w1,1 (15 +20)x 1.33 =19.95 +26.6 w1,2 (16 +0)x 0 =0 +0 w1,3 (5 +20)x 0 =0 +0 w1,4 (15 +40)x 0 =0 +0 w1,5 (5 +20)x 0 =0 +0 W1 =19.95 +26.6 =0.047 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 9.75 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (+)x 0 x 0 =0 +0 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =0 +0 =0.00 kips 0 9.75 Shear R1=0.227 kips R2=-0.227 kips Stress Ratio Vmax=0.23 kips Vallow.=1.24 x 1 =1.2375 kips OK .18 Flexure M=0.553 k-ft Mallow.=1.06 x 1 =1.0599 k-ft OK .52 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.284 +0.000 +0.000 +0.000 =0.28 =L <L OK deflection:.44 411 180 0.284 +0 D (L Only)=0.163 +0 +0 +0 =0.16 =L L OK deflection:.33 720 240 USE:1- 2X6 flexure: 0 0 shear: 2/7/25 12:00 AM RJ1 0 0 0 16 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet Tag Beam 5 L =5.41 ft Member=2x6 A =8.25 in^2 S =7.6 in^3 No. of members=1 I =20.8 in^4 CD=1.25 E =1,600,000 psi CF=1.30 Va =0.990 kips CV=1.00 Ma =0.567 k-ft Cr=1.15 Total Load L/n=180 Live Load L/n=240 L=5.41 ft 0.13 0.13 Uniform load (W1) D L Trib w1,1 (15 +20)x 1.33 =19.95 +26.6 w1,2 (16 +0)x 0 =0 +0 w1,3 (5 +20)x 0 =0 +0 w1,4 (15 +40)x 0 =0 +0 w1,5 (5 +20)x 0 =0 +0 W1 =19.95 +26.6 =0.047 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 5.41 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (+)x 0 x 0 =0 +0 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =0 +0 =0.00 kips 0 5.41 Shear R1=0.126 kips R2=-0.126 kips Stress Ratio Vmax=0.13 kips Vallow.=1.24 x 1 =1.2375 kips OK .10 Flexure M=0.170 k-ft Mallow.=1.06 x 1 =1.0599 k-ft OK .16 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.027 +0.000 +0.000 +0.000 =0.03 =L <L OK deflection:.07 2408 180 0.027 +0 D (L Only)=0.015 +0 +0 +0 =0.02 =L L OK deflection:.06 4214 240 USE:1- 2X6 flexure: 0 0 shear: 2/7/25 12:00 AM RJ2 0 0 0 17 Wood Beam LIC# : KW-06017148, Build:20.23.10.31 CASTILLO ENGINEERING INC.(c) ENERCALC INC 1983-2023 DESCRIPTION:RJ3 Project File: 24-181.ec6 Project Title:Engineer: CODE REFERENCES Calculations per NDS 2024, IBC 2024, ASCE 7-22 Load Combination Set : ASCE 7-22 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase Allowable Stress Design Douglas Fir-Larch No.2 900 900 1350 625 1600 580 180 575 31.21 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-22 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load : D = 0.0150, Lr = 0.020 ksf, Tributary Width = 1.330 ft, (ROOF) Load for Span Number 2 Uniform Load : D = 0.0150, Lr = 0.020 ksf, Tributary Width = 1.330 ft, (ROOF) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.341: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 3.959 ft 36.96 psi= = 1,681.88 psi 2x6Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 2x6 Maximum Shear Stress Ratio 0.164 : 1 8.310 ft= = 574.14 psi Maximum Deflection 1214 >=240 737Ratio =694 >=180 Max Downward Transient Deflection 0.081 in 1290Ratio =>=240 Max Upward Transient Deflection -0.054 in Ratio = Max Downward Total Deflection 0.142 in Ratio =>=180 Max Upward Total Deflection -0.095 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only Span: 2 : Lr Only Span: 1 : +D+Lr Span: 2 : +D+Lr .Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1 0.203 0.098 0.90 1.300 1.151.00 1.00 0.16 246.1 1,211.0 0.09 162.015.8 2 0.099 0.098 0.90 1.300 1.151.00 1.00 0.08 119.7 1,211.0 0.05 162.015.8 0.00.0 1 0.341 0.164 1.25 1.300 1.151.00 1.00 0.36 574.1 1,681.9 0.20 225.037.0 2 0.166 0.164 1.25 1.300 1.151.00 1.00 0.18 279.3 1,681.9 0.11 225.037.0 0.00.0 1 0.293 0.141 1.25 1.300 1.151.00 1.00 0.31 492.1 1,681.9 0.17 225.031.7 18 Wood Beam LIC# : KW-06017148, Build:20.23.10.31 CASTILLO ENGINEERING INC.(c) ENERCALC INC 1983-2023 DESCRIPTION:RJ3 Project File: 24-181.ec6 Project Title:Engineer: Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00Length = 2.750 ft 2 0.142 0.141 1.25 1.300 1.151.00 1.00 0.15 239.4 1,681.9 0.09 225.031.7 0.00.0 1 0.069 0.033 1.60 1.300 1.151.00 1.00 0.09 147.6 2,152.8 0.05 288.09.5 2 0.033 0.033 1.60 1.300 1.151.00 1.00 0.05 71.8 2,152.8 0.03 288.09.5 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.1424 4.204 0.0000 0.000 2 0.0000 4.204 -0.0950 2.750 . Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.184 0.352 Max Upward from Load Combinations 0.184 0.352 Max Upward from Load Cases 0.105 0.201 D Only 0.079 0.151 +D+Lr 0.184 0.352 +D+0.750Lr 0.157 0.302 +0.60D 0.047 0.090 Lr Only 0.105 0.201 19 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet Tag Beam 5 L =11.41 ft Member=6x10 A =52.25 in^2 S =82.7 in^3 No. of members=1 I =393.0 in^4 CD=1.25 E =1,600,000 psi CF=1.00 Va =5.922 kips CV=1.00 Ma =9.307 k-ft Cr=1.00 Total Load L/n=180 Live Load L/n=240 L=11.41 ft 2.49 2.49 Uniform load (W1) D L Trib w1,1 (15 +20)x 11.3 =169.95 +226.6 w1,2 (10 +0)x 4 =40 +0 w1,3 (5 +20)x 0 =0 +0 w1,4 (15 +40)x 0 =0 +0 w1,5 (5 +20)x 0 =0 +0 W1 =209.95 +226.6 =0.437 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 11.41 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (+)x 0 x 0 =0 +0 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =0 +0 =0.00 kips 0 11.41 Shear R1=2.491 kips R2=-2.491 kips Stress Ratio Vmax=2.49 kips Vallow.=7.40 x 1 =7.4021 kips OK .34 Flexure M=7.104 k-ft Mallow.=11.63 x 1 =11.634 k-ft OK .61 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.265 +0.000 +0.000 +0.000 =0.26 =L <L OK deflection:.35 517 180 0.265 +0 D (L Only)=0.137 +0 +0 +0 =0.14 =L L OK deflection:.24 996 240 USE:1- 6X10 flexure: 0 0 shear: 2/7/25 12:00 AM B1 0 0 0 20 ARCHITECT CASTILLO ENGINEERING JOB 1147 E. MARKET STREET Long Beach, CA 90805 ENGR. MC DATE JOB NO. SHEET NO. NOTCH ON COMPRESSION FACE AT END 1.75 5.53 0.58 4.95 V 2500 lbs member type= 2x8 b=5.5 in viga Fv=psi d 9.5 in viga Cd= dn= 4.95 in F'v=psi e=11.00 in 'e' > 'dn', therefore use Eq.(3.4-2)slope=4 :12 support member width w= 3.5 in 2024 NDS Equation 3.4-5 fv= 2b = 3 x =psi < psi, therefore NA 2 x 5.5 x 9.50 -- 4.95 x 11 Use Eq. (3.4-2) 2024 NDS Equation 3.4-2 fv= 1.5V =psi < psi, therefore Satisfactory (.65) b dn 138 213 12/02/2025 4.95 draftrer= 9.50 6x 170 1.25 213 2500 5.25 4.95dn Rec'd= TAG: B1 -1121 w 3V d-(d-dn)/(dn)*e 213 21 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet Tag Beam 5 L =4.00 ft Member=4x6 A =19.25 in^2 S =17.6 in^3 No. of members=1 I =48.5 in^4 CD=1.25 E =1,600,000 psi CF=1.30 Va =2.310 kips CV=1.00 Ma =1.323 k-ft Cr=1.00 Total Load L/n=180 Live Load L/n=240 L=4 ft 0.27 0.27 Uniform load (W1) D L Trib w1,1 (15 +20)x 2 =30 +40 w1,2 (16 +0)x 4 =64 +0 w1,3 (5 +20)x 0 =0 +0 w1,4 (15 +40)x 0 =0 +0 w1,5 (5 +20)x 0 =0 +0 W1 =94 +40 =0.134 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 4 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (+)x 0 x 0 =0 +0 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =0 +0 =0.00 kips 0 4 Shear R1=0.268 kips R2=-0.268 kips Stress Ratio Vmax=0.27 kips Vallow.=2.89 x 1 =2.8875 kips OK .09 Flexure M=0.268 k-ft Mallow.=2.15 x 1 =2.1506 k-ft OK .12 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.010 +0.000 +0.000 +0.000 =0.01 =L <L OK deflection:.04 4828 180 0.01 +0 D (L Only)=0.003 +0 +0 +0 =0 =L L OK deflection:.01 16175 240 USE:1- 4X6 flexure: 0 0 shear: 2/7/25 12:00 AM H1 0 0 0 22 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet Tag Beam 5 L =2.00 ft Member=4x4 A =12.25 in^2 S =7.1 in^3 No. of members=1 I =12.5 in^4 CD=1.25 E =1,600,000 psi CF=1.00 Va =1.470 kips CV=1.00 Ma =0.595 k-ft Cr=1.00 Total Load L/n=180 Live Load L/n=240 L=2 ft 0.43 0.43 Uniform load (W1) D L Trib w1,1 (15 +20)x 11.3 =168.75 +225 w1,2 (16 +0)x 2 =32 +0 w1,3 (5 +20)x 0 =0 +0 w1,4 (15 +40)x 0 =0 +0 w1,5 (5 +20)x 0 =0 +0 W1 =200.75 +225 =0.426 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 2 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (+)x 0 x 0 =0 +0 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =0 +0 =0.00 kips 0 2 Shear R1=0.426 kips R2=-0.426 kips Stress Ratio Vmax=0.43 kips Vallow.=1.84 x 1 =1.8375 kips OK .23 Flexure M=0.213 k-ft Mallow.=0.74 x 1 =0.7444 k-ft OK .29 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.008 +0.000 +0.000 +0.000 =0.01 =L <L OK deflection:.06 3133 180 0.008 +0 D (L Only)=0.004 +0 +0 +0 =0 =L L OK deflection:.04 5928 240 USE:1- 4X4 flexure: 0 0 shear: 2/7/25 12:00 AM H2 0 0 0 23 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet Tag Beam 5 L =4.00 ft Member=4x6 A =19.25 in^2 S =17.6 in^3 No. of members=1 I =48.5 in^4 CD=1.25 E =1,600,000 psi CF=1.30 Va =2.310 kips CV=1.00 Ma =1.323 k-ft Cr=1.00 Total Load L/n=180 Live Load L/n=240 L=4 ft 0.85 0.85 Uniform load (W1) D L Trib w1,1 (15 +20)x 11.3 =168.75 +225 w1,2 (16 +0)x 2 =32 +0 w1,3 (5 +20)x 0 =0 +0 w1,4 (15 +40)x 0 =0 +0 w1,5 (5 +20)x 0 =0 +0 W1 =200.75 +225 =0.426 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 4 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (+)x 0 x 0 =0 +0 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =0 +0 =0.00 kips 0 4 Shear R1=0.852 kips R2=-0.852 kips Stress Ratio Vmax=0.85 kips Vallow.=2.89 x 1 =2.8875 kips OK .29 Flexure M=0.852 k-ft Mallow.=2.15 x 1 =2.1506 k-ft OK .40 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.032 +0.000 +0.000 +0.000 =0.03 =L <L OK deflection:.12 1520 180 0.032 +0 D (L Only)=0.017 +0 +0 +0 =0.02 =L L OK deflection:.08 2876 240 USE:1- 4X6 flexure: 0 0 shear: 2/7/25 12:00 AM H3 0 0 0 24 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet Tag Beam 5 L =4.00 ft Member=4x6 A =19.25 in^2 S =17.6 in^3 No. of members=1 I =48.5 in^4 CD=1.25 E =1,600,000 psi CF=1.30 Va =2.310 kips CV=1.00 Ma =1.323 k-ft Cr=1.00 Total Load L/n=180 Live Load L/n=240 L=4 ft 0.55 0.55 Uniform load (W1) D L Trib w1,1 (15 +20)x 7 =105 +140 w1,2 (16 +0)x 2 =32 +0 w1,3 (5 +20)x 0 =0 +0 w1,4 (15 +40)x 0 =0 +0 w1,5 (5 +20)x 0 =0 +0 W1 =137 +140 =0.277 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 4 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (+)x 0 x 0 =0 +0 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =0 +0 =0.00 kips 0 4 Shear R1=0.554 kips R2=-0.554 kips Stress Ratio Vmax=0.55 kips Vallow.=2.89 x 1 =2.8875 kips OK .19 Flexure M=0.554 k-ft Mallow.=2.15 x 1 =2.1506 k-ft OK .26 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.021 +0.000 +0.000 +0.000 =0.02 =L <L OK deflection:.08 2336 180 0.021 +0 D (L Only)=0.01 +0 +0 +0 =0.01 =L L OK deflection:.05 4622 240 USE:1- 4X6 flexure: 0 0 shear: 2/7/25 12:00 AM H4 0 0 0 25 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet Tag Beam 5 L =4.00 ft Member=4x6 A =19.25 in^2 S =17.6 in^3 No. of members=1 I =48.5 in^4 CD=1.25 E =1,600,000 psi CF=1.30 Va =2.310 kips CV=1.00 Ma =1.323 k-ft Cr=1.00 Total Load L/n=180 Live Load L/n=240 L=4 ft 0.24 0.24 Uniform load (W1) D L Trib w1,1 (15 +20)x 2 =30 +40 w1,2 (16 +0)x 3 =48 +0 w1,3 (5 +20)x 0 =0 +0 w1,4 (15 +40)x 0 =0 +0 w1,5 (5 +20)x 0 =0 +0 W1 =78 +40 =0.118 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 4 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (+)x 0 x 0 =0 +0 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =0 +0 =0.00 kips 0 4 Shear R1=0.236 kips R2=-0.236 kips Stress Ratio Vmax=0.24 kips Vallow.=2.89 x 1 =2.8875 kips OK .08 Flexure M=0.236 k-ft Mallow.=2.15 x 1 =2.1506 k-ft OK .11 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.009 +0.000 +0.000 +0.000 =0.01 =L <L OK deflection:.03 5483 180 0.009 +0 D (L Only)=0.003 +0 +0 +0 =0 =L L OK deflection:.01 16175 240 USE:1- 4X6 flexure: 0 0 shear: 2/7/25 12:00 AM H5 0 0 0 26 FLOOR/LOW ROOF KEYPLAN FJ1 FJ2 FJ3 FJ4 FJ5 H1 H2 H2(E)H1 (E)H2 B1 B3 B4 B5 B6 B7 B8 B13 B10 B11 B12 RJ1 C.J. C. J .HB1 B2 FJ5 B9 27 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet Tag Beam 5 L =2.00 ft Member=2x6 A =8.25 in^2 S =7.6 in^3 No. of members=1 I =20.8 in^4 CD=1.00 E =1,600,000 psi CF=1.30 Va =0.990 kips CV=1.00 Ma =0.567 k-ft Cr=1.15 Total Load L/n=240 Live Load L/n=360 L=2 ft 0.05 0.05 Uniform load (W1) D L Trib w1,1 (15 +20)x 1.33 =19.95 +26.6 w1,2 (16 +0)x 0 =0 +0 w1,3 (15 +40)x 0 =0 +0 w1,4 (15 +60)x 0 =0 +0 w1,5 (5 +20)x 0 =0 +0 W1 =19.95 +26.6 =0.047 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 2 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (+)x 0 x 0 =0 +0 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =0 +0 =0.00 kips 0 2 Shear R1=0.047 kips R2=-0.047 kips Stress Ratio Vmax=0.05 kips Vallow.=0.99 x 1 =0.99 kips OK .05 Flexure M=0.023 k-ft Mallow.=0.85 x 1 =0.8479 k-ft OK .03 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.001 +0.000 +0.000 +0.000 =0.00 =L <L OK deflection:.01 47655 240 5E-04 +0 D (L Only)=3E-04 +0 +0 +0 =0 =L L OK deflection:.00 83396 360 USE:1- 2X6 shear: 2/10/25 12:00 AM RJ1 0 0 0 flexure: 0 0 28 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet Tag Beam 5 L =15.66 ft Member=2x12 A =16.88 in^2 S =31.6 in^3 No. of members=1 I =178.0 in^4 CD=1.00 E =1,600,000 psi CF=1.00 Va =2.025 kips CV=1.00 Ma =2.373 k-ft Cr=1.15 Total Load L/n=240 Live Load L/n=360 L=15.66 ft 0.57 0.57 Uniform load (W1) D L Trib w1,1 (15 +20)x 0 =0 +0 w1,2 (16 +0)x 0 =0 +0 w1,3 (15 +40)x 1.33 =19.95 +53.2 w1,4 (15 +60)x 0 =0 +0 w1,5 (5 +20)x 0 =0 +0 W1 =19.95 +53.2 =0.073 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 15.66 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (+)x 0 x 0 =0 +0 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =0 +0 =0.00 kips 0 15.66 Shear R1=0.573 kips R2=-0.573 kips Stress Ratio Vmax=0.57 kips Vallow.=2.03 x 1 =2.025 kips OK .28 Flexure M=2.242 k-ft Mallow.=2.73 x 1 =2.729 k-ft OK .82 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.348 +0.000 +0.000 +0.000 =0.35 =L <L OK deflection:.44 541 240 0.348 +0 D (L Only)=0.253 +0 +0 +0 =0.25 =L L OK deflection:.48 743 360 USE:1- 2X12 shear: 2/10/25 12:00 AM FJ1 0 0 0 flexure: 0 0 29 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet Tag Beam 5 L =3.08 ft Member=2x12 A =16.88 in^2 S =31.6 in^3 No. of members=1 I =178.0 in^4 CD=1.00 E =1,600,000 psi CF=1.00 Va =2.025 kips CV=1.00 Ma =2.373 k-ft Cr=1.15 Total Load L/n=240 Live Load L/n=360 L=3.08 ft 0.11 0.11 Uniform load (W1) D L Trib w1,1 (15 +20)x 0 =0 +0 w1,2 (16 +0)x 0 =0 +0 w1,3 (15 +40)x 1.33 =19.95 +53.2 w1,4 (15 +60)x 0 =0 +0 w1,5 (5 +20)x 0 =0 +0 W1 =19.95 +53.2 =0.073 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 3.08 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (+)x 0 x 0 =0 +0 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =0 +0 =0.00 kips 0 3.08 Shear R1=0.113 kips R2=-0.113 kips Stress Ratio Vmax=0.11 kips Vallow.=2.03 x 1 =2.025 kips OK .06 Flexure M=0.087 k-ft Mallow.=2.73 x 1 =2.729 k-ft OK .03 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.001 +0.000 +0.000 +0.000 =0.00 =L <L OK deflection:.00 71059 240 5E-04 +0 D (L Only)=4E-04 +0 +0 +0 =0 =L L OK deflection:.00 97706 360 USE:1- 2X12 shear: 2/10/25 12:00 AM FJ2 0 0 0 flexure: 0 0 30 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet Tag Beam 5 L =11.16 ft Member=2x12 A =16.88 in^2 S =31.6 in^3 No. of members=1 I =178.0 in^4 CD=1.00 E =1,600,000 psi CF=1.00 Va =2.025 kips CV=1.00 Ma =2.373 k-ft Cr=1.15 Total Load L/n=240 Live Load L/n=360 L=11.16 ft 0.41 0.41 Uniform load (W1) D L Trib w1,1 (15 +20)x 0 =0 +0 w1,2 (16 +0)x 0 =0 +0 w1,3 (15 +40)x 1.33 =19.95 +53.2 w1,4 (15 +60)x 0 =0 +0 w1,5 (5 +20)x 0 =0 +0 W1 =19.95 +53.2 =0.073 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 11.16 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (+)x 0 x 0 =0 +0 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =0 +0 =0.00 kips 0 11.16 Shear R1=0.408 kips R2=-0.408 kips Stress Ratio Vmax=0.41 kips Vallow.=2.03 x 1 =2.025 kips OK .20 Flexure M=1.139 k-ft Mallow.=2.73 x 1 =2.729 k-ft OK .42 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.090 +0.000 +0.000 +0.000 =0.09 =L <L OK deflection:.16 1494 240 0.09 +0 D (L Only)=0.065 +0 +0 +0 =0.07 =L L OK deflection:.18 2054 360 USE:1- 2X12 shear: 2/10/25 12:00 AM FJ3 0 0 0 flexure: 0 0 31 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet Tag Beam 5 L =7.41 ft Member=2x12 A =16.88 in^2 S =31.6 in^3 No. of members=1 I =178.0 in^4 CD=1.00 E =1,600,000 psi CF=1.00 Va =2.025 kips CV=1.00 Ma =2.373 k-ft Cr=1.15 Total Load L/n=240 Live Load L/n=360 L=7.41 ft 0.27 0.27 Uniform load (W1) D L Trib w1,1 (15 +20)x 0 =0 +0 w1,2 (16 +0)x 0 =0 +0 w1,3 (15 +40)x 1.33 =19.95 +53.2 w1,4 (15 +60)x 0 =0 +0 w1,5 (5 +20)x 0 =0 +0 W1 =19.95 +53.2 =0.073 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 7.41 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (+)x 0 x 0 =0 +0 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =0 +0 =0.00 kips 0 7.41 Shear R1=0.271 kips R2=-0.271 kips Stress Ratio Vmax=0.27 kips Vallow.=2.03 x 1 =2.025 kips OK .13 Flexure M=0.502 k-ft Mallow.=2.73 x 1 =2.729 k-ft OK .18 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.017 +0.000 +0.000 +0.000 =0.02 =L <L OK deflection:.05 5103 240 0.017 +0 D (L Only)=0.013 +0 +0 +0 =0.01 =L L OK deflection:.05 7016 360 USE:1- 2X12 shear: 2/12/25 12:00 AM FJ4 0 0 0 flexure: 0 0 32 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet Tag Beam 5 L =4.17 ft Member=2x12 A =16.88 in^2 S =31.6 in^3 No. of members=1 I =178.0 in^4 CD=1.00 E =1,600,000 psi CF=1.00 Va =2.025 kips CV=1.00 Ma =2.373 k-ft Cr=1.15 Total Load L/n=240 Live Load L/n=360 L=4.17 ft 0.15 0.15 Uniform load (W1) D L Trib w1,1 (15 +20)x 0 =0 +0 w1,2 (16 +0)x 0 =0 +0 w1,3 (15 +40)x 1.33 =19.95 +53.2 w1,4 (15 +60)x 0 =0 +0 w1,5 (5 +20)x 0 =0 +0 W1 =19.95 +53.2 =0.073 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 4.17 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (+)x 0 x 0 =0 +0 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =0 +0 =0.00 kips 0 4.17 Shear R1=0.153 kips R2=-0.153 kips Stress Ratio Vmax=0.15 kips Vallow.=2.03 x 1 =2.025 kips OK .08 Flexure M=0.159 k-ft Mallow.=2.73 x 1 =2.729 k-ft OK .06 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.002 +0.000 +0.000 +0.000 =0.00 =L <L OK deflection:.01 28633 240 0.002 +0 D (L Only)=0.001 +0 +0 +0 =0 =L L OK deflection:.01 39370 360 USE:1- 2X12 shear: 2/12/25 12:00 AM FJ5 0 0 0 flexure: 0 0 33 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet Tag Beam 5 L =16.16 ft Member=5.25x11.875 PSL A =62.34 in^2 S =123.4 in^3 No. of members=1 I =732.6 in^4 CD=1.00 E =2,000,000 psi CF=1.00 Va =12.053 kips CV=1.00 Ma =29.819 k-ft Cr=1.00 Total Load L/n=240 Live Load L/n=360 L=16.16 ft 4.95 4.95 Uniform load (W1) D L Trib w1,1 (15 +20)x 11.3 =168.75 +225 w1,2 (16 +0)x 8 =128 +0 w1,3 (15 +40)x 0 =0 +0 w1,4 (15 +40)x 1.66 =24.9 +66.4 w1,5 (5 +20)x 0 =0 +0 W1 =321.65 +291.4 =0.613 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 16.16 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (+)x 0 x 0 =0 +0 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =0 +0 =0.00 kips 0 16.16 Shear R1=4.953 kips R2=-4.953 kips Stress Ratio Vmax=4.95 kips Vallow.=12.05 x 1 =12.053 kips OK .41 Flexure M=20.012 k-ft Mallow.=29.85 x 1 =29.854 k-ft OK .67 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.642 +0.000 +0.000 +0.000 =0.64 =L <L OK deflection:.79 302 240 0.642 +0 D (L Only)=0.305 +0 +0 +0 =0.31 =L L OK deflection:.57 635 360 USE:1- 5.25X11.875 PSL flexure: 0 0 shear: 2/7/25 12:00 AM B1 0 0 0 34 CASTILLO ENGINEERING INC.Project KEMP ST 1205 Pine Avenue, Suite 201 Long Beach, CA 90813 Engr.Date:Job No.25-181 Sheet Elements Supporting Discontinuous Walls or Frames (ASCE 7-16, Section 12.3.3.3) Tag Load Combination with Overstrength (ASCE7-05 Section 12.4.3.3) Case:6 :1.1523 D +0.75 L +1.88 E Beam Member=5.25x11.875 PSL L =16.166667 ft No. of members=1 A =62.34 in^2 CD=1.60 S =123.4 in^3 CF=1.00 Va =12.053 kips CV=1.00 Ma =29.819 k-ft MOD FACTOR1.20 Seismic load (PE1,PE2,PE3,PE4) v h Wo location (ft) E1 =537 x 8 x 1.88 =-8.06 kips UP 5.83 PE2 =537 x 8 x 1.88 =8.06 kips DOWN 10.5 PE3 =0 x 8 x 1.88 =0.00 kips PE4 =0 x 8 x 1.88 =0.00 kips Uniform load (w1) D L Trib w1,1 (15 +20)x 11.3 =169.5 +226 w1,2 (16 +0)x 8 =128 +0 w1,3 (15 +40)x 1.66 =24.9 +66.4 w1,4 (+)x 0 =0 +0 w1,5 (+)x 0 =0 +0 w1 =322.4 +292.4 =0.615 klf factored w1=1.152 x 322.4 +0.75 x 292.4 =0.591 klf Point Load (P1) D L Trib.1 Trib.2 p1,1 (+)x 0 x 0 =0 +0 p1,2 (+)x 0 x 0 =0 +0 p1,3 (+)x 0 x 0 =0 +0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 P1 =0 +0 =0 kips 16.1666667 location (ft) factored P1=1.152 x 0 +0.75 x 0 =0.00 kips 0 ft Point Load (P2) D L Trib.1 Trib.2 p2,1 (+)x 0 x 0 =0 +0 p2,2 (+)x 0 x 0 =0 +0 p2,4 (+)x 0 x 0 =0 +0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 P2 =0 +0 =0.00 kips 16.1666667 location (ft) factored P2=1.152 x 0 +0.75 x 0 =0.00 kips 0 Shear CD ** Factor per ASCE7-16 12.4.3.3 R1=2.45 kips Vallow.=12.053 1.60 1.20 =23.1 R2=-7.10 kips Stress Ratio Vmax=7.10 kips Vallow.=23.14 x 1 =23.14 kips OK shear:.31 Flexure CD CF Cv * Mallow.=29.819 1.60 1.00 1.00 1.20 =57.3 M=30.73 k-ft Mallow.=57.32 x 1 =57.32 k-ft OK flexure:.54 USE:1- 5.25x11.875 PSL B1 6/9/25 12:00 AM 35 Wood Beam LIC# : KW-06017148, Build:20.23.10.31 CASTILLO ENGINEERING INC.(c) ENERCALC INC 1983-2023 DESCRIPTION:B2 Project File: 24-181.ec6 Project Title:Engineer: CODE REFERENCES Calculations per NDS 2024, IBC 2024, ASCE 7-22 Load Combination Set : ASCE 7-22 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist Parallam PSL 2.0E 2900 2900 2900 750 2000 1016.535 290 2025 45.07 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-22 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load : D = 0.0150, Lr = 0.020 ksf, Extent = 3.330 -->> 14.080 ft, Tributary Width = 7.0->0.0 ft, (ROOF) Uniform Load : D = 0.0160 ksf, Extent = 3.330 -->> 14.080 ft, Tributary Width = 8.0 ft, (WALL) Uniform Load : D = 0.0150, L = 0.040 ksf, Extent = 0.0 -->> 14.080 ft, Tributary Width = 5.410 ft, (FLOOR) Uniform Load : D = 0.0150, L = 0.040 ksf, Extent = 0.0 -->> 3.330 ft, Tributary Width = 0.670 ft, (FLOOR) Point Load : D = 1.350, L = 3.60 k @ 3.580 ft, (B1) Point Load : D = 1.067, Lr = 1.423 k @ 3.580 ft, (B1 ROOF) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.622: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 4.060 ft 129.49 psi= = 2,903.37 psi 7x11.875Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 290.00 psi== Section used for this span 7x11.875 Maximum Shear Stress Ratio 0.447 : 1 0.000 ft= = 1,806.35 psi Maximum Deflection 0 <360 386Ratio =0 <240 Max Downward Transient Deflection 0.231 in 730Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.437 in Ratio =>=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only n/a Span: 1 : +D+0.750Lr+0.750L n/a .Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1 0.313 0.216 0.90 1.001 1.001.00 1.00 11.20 817.2 2,613.0 3.13 261.056.4 0.00.0 1 0.622 0.447 1.00 1.001 1.001.00 1.00 24.76 1,806.3 2,903.4 7.18 290.0129.5 0.00.0 36 Wood Beam LIC# : KW-06017148, Build:20.23.10.31 CASTILLO ENGINEERING INC.(c) ENERCALC INC 1983-2023 DESCRIPTION:B2 Project File: 24-181.ec6 Project Title:Engineer: Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00Length = 14.080 ft 1 0.327 0.228 1.25 1.001 1.001.00 1.00 16.27 1,186.8 3,629.2 4.57 362.582.5 0.00.0 1 0.507 0.361 1.25 1.001 1.001.00 1.00 25.20 1,838.3 3,629.2 7.25 362.5130.8 0.00.0 1 0.466 0.334 1.15 1.001 1.001.00 1.00 21.35 1,557.2 3,338.9 6.16 333.5111.2 0.00.0 1 0.106 0.073 1.60 1.001 1.001.00 1.00 6.72 490.3 4,645.4 1.88 464.033.9 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+0.750Lr+0.750L 1 0.4373 6.629 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 7.514 4.767 Max Upward from Load Combinations 7.514 4.767 Max Upward from Load Cases 4.287 2.449 D Only 3.216 2.318 +D+L 7.503 4.767 +D+Lr 4.660 3.049 +D+0.750Lr+0.750L 7.514 4.703 +D+0.750L 6.431 4.155 +0.60D 1.929 1.391 Lr Only 1.444 0.731 L Only 4.287 2.449 37 Wood Beam LIC# : KW-06017148, Build:20.24.10.30 CASTILLO ENGINEERING INC.(c) ENERCALC, LLC 1982-2025 DESCRIPTION:B2 Overstrength Project File: 25-181.ec6 Project Title: Engineer: CODE REFERENCES Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist Parallam PSL 2.0E 2,900.0 2,900.0 2,900.0 750.0 2,000.0 1,016.54 290.0 2,025.0 45.070 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load : D = 0.0150, Lr = 0.020 ksf, Extent = 3.330 -->> 14.080 ft, Tributary Width = 7.0->0.0 ft, (ROOF) Uniform Load : D = 0.0160 ksf, Extent = 3.330 -->> 14.080 ft, Tributary Width = 8.0 ft, (WALL) Uniform Load : D = 0.0150, L = 0.040 ksf, Extent = 0.0 -->> 14.080 ft, Tributary Width = 5.410 ft, (FLOOR) Uniform Load : D = 0.0150, L = 0.040 ksf, Extent = 0.0 -->> 3.330 ft, Tributary Width = 0.670 ft, (FLOOR) Point Load : D = 1.350, L = 3.60 k @ 3.580 ft, (B1) Point Load : D = 1.067, Lr = 1.423 k @ 3.580 ft, (B1 ROOF) Point Load : E = 0.80 k @ 3.670 ft, (Y2) Point Load : E = -0.80 k @ 6.167 ft, (Y2) Point Load : E = 0.80 k @ 10.667 ft, (Y2) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.622: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 4.060 ft 129.49 psi= = 2,903.37 psi 7x11.875Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 290.00 psi== Section used for this span 7x11.875 Maximum Shear Stress Ratio 0.447 : 1 0.000 ft= = 1,806.35 psi Maximum Deflection 730 >=360 386 Ratio =0 <240 Max Downward Transient Deflection 0.231 in 9894 Ratio =>=360 Max Upward Transient Deflection -0.017 in Ratio = Max Downward Total Deflection 0.437 in Ratio =>=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only Span: 1 : E Only * -1.0 Span: 1 : +D+0.750Lr+0.750L n/a .Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 38 Wood Beam LIC# : KW-06017148, Build:20.24.10.30 CASTILLO ENGINEERING INC.(c) ENERCALC, LLC 1982-2025 DESCRIPTION:B2 Overstrength Project File: 25-181.ec6 Project Title: Engineer: Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00Length = 14.080 ft 1 0.313 0.216 0.90 1.001 1.001.00 1.00 11.20 817.2 2,613.0 3.13 261.056.4 +D+L 0.00.0 Length = 14.080 ft 1 0.622 0.447 1.00 1.001 1.001.00 1.00 24.76 1,806.3 2,903.4 7.18 290.0129.5 +D+Lr 0.00.0 Length = 14.080 ft 1 0.327 0.228 1.25 1.001 1.001.00 1.00 16.27 1,186.8 3,629.2 4.57 362.582.5 +D+0.750Lr+0.750L 0.00.0 Length = 14.080 ft 1 0.507 0.361 1.25 1.001 1.001.00 1.00 25.20 1,838.3 3,629.2 7.25 362.5130.8 +D+0.750L 0.00.0 Length = 14.080 ft 1 0.466 0.334 1.15 1.001 1.001.00 1.00 21.35 1,557.2 3,338.9 6.16 333.5111.2 +0.60D 0.00.0 Length = 14.080 ft 1 0.106 0.073 1.60 1.001 1.001.00 1.00 6.72 490.3 4,645.4 1.88 464.033.9 +1.203D+1.750E 0.00.0 Length = 14.080 ft 1 0.241 0.169 1.60 1.001 1.001.00 1.00 15.33 1,118.0 4,645.4 4.35 464.078.5 +1.203D-1.750E 0.00.0 Length = 14.080 ft 1 0.205 0.123 1.60 1.001 1.001.00 1.00 13.09 954.5 4,645.4 3.17 464.057.3 +1.152D+0.750L+1.313E 0.00.0 Length = 14.080 ft 1 0.386 0.275 1.60 1.001 1.001.00 1.00 24.56 1,791.6 4,645.4 7.08 464.0127.8 +1.152D+0.750L-1.313E 0.00.0 Length = 14.080 ft 1 0.348 0.241 1.60 1.001 1.001.00 1.00 22.14 1,615.1 4,645.4 6.20 464.0111.9 +0.3970D+1.750E 0.00.0 Length = 14.080 ft 1 0.102 0.071 1.60 1.001 1.001.00 1.00 6.49 473.4 4,645.4 1.83 464.033.0 +0.3970D-1.750E 0.00.0 Length = 14.080 ft 1 0.066 0.047 1.60 1.001 1.001.00 1.00 4.23 308.7 4,645.4 1.20 464.021.6 . LocationLoad CombinationMax.LocationLoad CombinationSpan Max. Overall Maximum Deflections "-" Defl in Span in Span"+" Defl +D+0.750Lr+0.750L1 6.629 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 7.514 4.767 Max Upward from Load Combinations 7.514 4.767 Max Upward from Load Cases 4.287 2.449 Max Downward from all Load Conditions (Resisting Uplift)-0.336 -0.464 Max Downward from Load Cases (Resisting Uplift)-0.336 -0.464 D Only 3.216 2.318 +D+L 7.503 4.767 +D+Lr 4.660 3.049 +D+0.750Lr+0.750L 7.514 4.703 +D+0.750L 6.431 4.155 +0.60D 1.929 1.391 +D+0.70E 3.451 2.643 +D-0.70E 2.981 1.993 +D+0.750L+0.5250E 6.607 4.398 +D+0.750L-0.5250E 6.255 3.911 +0.60D+0.70E 2.165 1.716 +0.60D-0.70E 1.694 1.066 Lr Only 1.444 0.731 L Only 4.287 2.449 E Only 0.336 0.464 E Only * -1.0 -0.336 -0.464 39 Wood Beam LIC# : KW-06017148, Build:20.23.10.31 CASTILLO ENGINEERING INC.(c) ENERCALC INC 1983-2023 DESCRIPTION:B3 Project File: 24-181.ec6 Project Title:Engineer: CODE REFERENCES Calculations per NDS 2024, IBC 2024, ASCE 7-22 Load Combination Set : ASCE 7-22 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist Parallam PSL 2.0E 2900 2900 2900 750 2000 1016.535 290 2025 45.07 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-22 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.0150, Lr = 0.020 ksf, Tributary Width = 2.0 ft, (ROOF) Uniform Load : D = 0.0160 ksf, Tributary Width = 9.750 ft, (WALL) Uniform Load : D = 0.0150, L = 0.040 ksf, Tributary Width = 0.670 ft, (FLOOR) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.182: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 5.705 ft 38.18 psi= = 2,903.37 psi 3.5x11.875Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 290.00 psi== Section used for this span 3.5x11.875 Maximum Shear Stress Ratio 0.132 : 1 0.000 ft= = 529.04 psi Maximum Deflection 0 <360 1416Ratio =0 <240 Max Downward Transient Deflection 0.016 in 8717Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.097 in Ratio =>=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+0.750Lr+0.750L n/a .Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1 0.178 0.129 0.90 1.001 1.001.00 1.00 3.19 465.4 2,613.0 0.93 261.033.6 0.00.0 1 0.182 0.132 1.00 1.001 1.001.00 1.00 3.63 529.0 2,903.4 1.06 290.038.2 0.00.0 1 0.154 0.112 1.25 1.001 1.001.00 1.00 3.84 560.4 3,629.2 1.12 362.540.4 0.00.0 1 0.161 0.116 1.25 1.001 1.001.00 1.00 4.01 584.4 3,629.2 1.17 362.542.2 0.00.0 40 Wood Beam LIC# : KW-06017148, Build:20.23.10.31 CASTILLO ENGINEERING INC.(c) ENERCALC INC 1983-2023 DESCRIPTION:B3 Project File: 24-181.ec6 Project Title:Engineer: Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00Length = 11.410 ft 1 0.154 0.111 1.15 1.001 1.001.00 1.00 3.52 513.1 3,338.9 1.03 333.537.0 0.00.0 1 0.060 0.043 1.60 1.001 1.001.00 1.00 1.91 279.3 4,645.4 0.56 464.020.2 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+0.750Lr+0.750L 1 0.0967 5.747 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 1.404 1.404 Max Upward from Load Combinations 1.404 1.404 Max Upward from Load Cases 1.118 1.118 D Only 1.118 1.118 +D+L 1.271 1.271 +D+Lr 1.347 1.347 +D+0.750Lr+0.750L 1.404 1.404 +D+0.750L 1.233 1.233 +0.60D 0.671 0.671 Lr Only 0.228 0.228 L Only 0.153 0.153 41 Wood Beam LIC# : KW-06017148, Build:20.24.10.30 CASTILLO ENGINEERING INC.(c) ENERCALC, LLC 1982-2025 DESCRIPTION:B3 Overstrength Project File: 25-181.ec6 Project Title: Engineer: CODE REFERENCES Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist Parallam PSL 2.0E 2,900.0 2,900.0 2,900.0 750.0 2,000.0 1,016.54 290.0 2,025.0 45.070 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.0150, Lr = 0.020 ksf, Tributary Width = 2.0 ft, (ROOF) Uniform Load : D = 0.0160 ksf, Tributary Width = 9.750 ft, (WALL) Uniform Load : D = 0.0150, L = 0.040 ksf, Tributary Width = 0.670 ft, (FLOOR) Point Load : E = 0.7473 k @ 3.50 ft, (X3) Point Load : E = -0.7473 k @ 8.0 ft, (X3) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.182: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 5.705 ft 38.18 psi= = 2,903.37 psi 3.5x11.875Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 290.00 psi== Section used for this span 3.5x11.875 Maximum Shear Stress Ratio 0.132 : 1 0.000 ft= = 529.04 psi Maximum Deflection 8717 >=360 1416 Ratio =0 <240 Max Downward Transient Deflection 0.016 in 31363 Ratio =>=360 Max Upward Transient Deflection -0.004 in Ratio = Max Downward Total Deflection 0.097 in Ratio =>=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only Span: 1 : E Only Span: 1 : +D+0.750Lr+0.750L n/a .Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 Length = 11.410 ft 1 0.178 0.129 0.90 1.001 1.001.00 1.00 3.19 465.4 2,613.0 0.93 261.033.6 +D+L 0.00.0 Length = 11.410 ft 1 0.182 0.132 1.00 1.001 1.001.00 1.00 3.63 529.0 2,903.4 1.06 290.038.2 +D+Lr 0.00.0 42 Wood Beam LIC# : KW-06017148, Build:20.24.10.30 CASTILLO ENGINEERING INC.(c) ENERCALC, LLC 1982-2025 DESCRIPTION:B3 Overstrength Project File: 25-181.ec6 Project Title: Engineer: Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00Length = 11.410 ft 1 0.154 0.112 1.25 1.001 1.001.00 1.00 3.84 560.4 3,629.2 1.12 362.540.4 +D+0.750Lr+0.750L 0.00.0 Length = 11.410 ft 1 0.161 0.116 1.25 1.001 1.001.00 1.00 4.01 584.4 3,629.2 1.17 362.542.2 +D+0.750L 0.00.0 Length = 11.410 ft 1 0.154 0.111 1.15 1.001 1.001.00 1.00 3.52 513.1 3,338.9 1.03 333.537.0 +0.60D 0.00.0 Length = 11.410 ft 1 0.060 0.043 1.60 1.001 1.001.00 1.00 1.91 279.3 4,645.4 0.56 464.020.2 +1.203D+1.750E 0.00.0 Length = 11.410 ft 1 0.159 0.127 1.60 1.001 1.001.00 1.00 5.07 739.3 4,645.4 1.64 464.059.0 +1.152D+0.750L+1.313E 0.00.0 Length = 11.410 ft 1 0.149 0.121 1.60 1.001 1.001.00 1.00 4.76 694.0 4,645.4 1.55 464.056.1 +0.3970D+1.750E 0.00.0 Length = 11.410 ft 1 0.090 0.075 1.60 1.001 1.001.00 1.00 2.88 420.3 4,645.4 0.97 464.035.0 . LocationLoad CombinationMax.LocationLoad CombinationSpan Max. Overall Maximum Deflections "-" Defl in Span in Span"+" Defl +D+0.750Lr+0.750L1 5.747 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 1.404 1.404 Max Upward from Load Combinations 1.404 1.404 Max Upward from Load Cases 1.118 1.118 Max Downward from all Load Conditions (Resisting Uplift)-0.295 Max Downward from Load Cases (Resisting Uplift)-0.295 D Only 1.118 1.118 +D+L 1.271 1.271 +D+Lr 1.347 1.347 +D+0.750Lr+0.750L 1.404 1.404 +D+0.750L 1.233 1.233 +0.60D 0.671 0.671 +D+0.70E 1.325 0.912 +D+0.750L+0.5250E 1.388 1.078 +0.60D+0.70E 0.877 0.465 Lr Only 0.228 0.228 L Only 0.153 0.153 E Only 0.295 -0.295 43 Wood Beam LIC# : KW-06017148, Build:20.23.10.31 CASTILLO ENGINEERING INC.(c) ENERCALC INC 1983-2023 DESCRIPTION:B4 Project File: 24-181.ec6 Project Title:Engineer: CODE REFERENCES Calculations per NDS 2024, IBC 2024, ASCE 7-22 Load Combination Set : ASCE 7-22 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist Parallam PSL 2.0E 2,900.0 2,900.0 2,900.0 750.0 2,000.0 1,016.54 290.0 2,025.0 45.070 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-22 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load : D = 0.0150, Lr = 0.020 ksf, Extent = 3.330 -->> 14.080 ft, Tributary Width = 7.0 ft, (ROOF) Uniform Load : D = 0.0160 ksf, Extent = 0.0 -->> 14.080 ft, Tributary Width = 8.0 ft, (WALL) Uniform Load : D = 0.0150, L = 0.040 ksf, Extent = 0.0 -->> 14.080 ft, Tributary Width = 5.410 ft, (FLOOR) Point Load : D = 1.067, Lr = 1.423 k @ 3.580 ft, (B1 ROOF) Uniform Load : D = 0.0150, Lr = 0.020 ksf, Extent = 0.0 -->> 3.330 ft, Tributary Width = 2.0 ft, (ROOF) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.499: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 6.578 ft 93.01 psi= = 2,903.37 psi 5.25x11.875Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 290.00 psi== Section used for this span 5.25x11.875 Maximum Shear Stress Ratio 0.321 : 1 0.000 ft= = 1,449.52 psi Maximum Deflection 0 <360 380Ratio =0 <240 Max Downward Transient Deflection 0.146 in 1157Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.444 in Ratio =>=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+0.750Lr+0.750L n/a .Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1 0.357 0.235 0.90 1.001 1.001.00 1.00 9.58 931.7 2,613.0 2.55 261.061.4 0.00.0 1 0.499 0.321 1.00 1.001 1.001.00 1.00 14.90 1,449.5 2,903.4 3.87 290.093.0 0.00.0 1 0.417 0.283 1.25 1.001 1.001.00 1.00 15.58 1,514.9 3,629.2 4.27 362.5102.7 44 Wood Beam LIC# : KW-06017148, Build:20.23.10.31 CASTILLO ENGINEERING INC.(c) ENERCALC INC 1983-2023 DESCRIPTION:B4 Project File: 24-181.ec6 Project Title:Engineer: Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00+D+0.750Lr+0.750L 1.001 1.001.00 1.00 0.0 0.00 0.00.0 1 0.483 0.320 1.25 1.001 1.001.00 1.00 18.01 1,752.0 3,629.2 4.82 362.5116.0 0.00.0 1 0.395 0.255 1.15 1.001 1.001.00 1.00 13.57 1,319.7 3,338.9 3.54 333.585.1 0.00.0 1 0.120 0.079 1.60 1.001 1.001.00 1.00 5.75 559.0 4,645.4 1.53 464.036.9 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+0.750Lr+0.750L 1 0.4442 6.886 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 5.245 4.577 Max Upward from Load Combinations 5.245 4.577 Max Upward from Load Cases 2.787 2.453 D Only 2.787 2.453 +D+L 4.311 3.977 +D+Lr 4.540 3.761 +D+0.750Lr+0.750L 5.245 4.577 +D+0.750L 3.930 3.596 +0.60D 1.672 1.472 Lr Only 1.753 1.308 L Only 1.523 1.523 45 Wood Beam LIC# : KW-06017148, Build:20.24.10.30 CASTILLO ENGINEERING INC.(c) ENERCALC, LLC 1982-2025 DESCRIPTION:B4 Overstrength Project File: 25-181.ec6 Project Title: Engineer: CODE REFERENCES Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist Parallam PSL 2.0E 2,900.0 2,900.0 2,900.0 750.0 2,000.0 1,016.54 290.0 2,025.0 45.070 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load : D = 0.0150, Lr = 0.020 ksf, Extent = 3.330 -->> 14.080 ft, Tributary Width = 7.0 ft, (ROOF) Uniform Load : D = 0.0160 ksf, Extent = 0.0 -->> 14.080 ft, Tributary Width = 8.0 ft, (WALL) Uniform Load : D = 0.0150, L = 0.040 ksf, Extent = 0.0 -->> 14.080 ft, Tributary Width = 5.410 ft, (FLOOR) Point Load : D = 1.067, Lr = 1.423 k @ 3.580 ft, (B1 ROOF) Uniform Load : D = 0.0150, Lr = 0.020 ksf, Extent = 0.0 -->> 3.330 ft, Tributary Width = 2.0 ft, (ROOF) Point Load : E = 1.196 k @ 3.580 ft, (Y3) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.499: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 6.578 ft 93.01 psi= = 2,903.37 psi 5.25x11.875Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 290.00 psi== Section used for this span 5.25x11.875 Maximum Shear Stress Ratio 0.321 : 1 0.000 ft= = 1,449.52 psi Maximum Deflection 1157 >=360 380 Ratio =0 <240 Max Downward Transient Deflection 0.146 in 2888 Ratio =>=360 Max Upward Transient Deflection -0.058 in Ratio = Max Downward Total Deflection 0.444 in Ratio =>=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only Span: 1 : E Only * -1.0 Span: 1 : +D+0.750Lr+0.750L n/a .Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 Length = 14.080 ft 1 0.357 0.235 0.90 1.001 1.001.00 1.00 9.58 931.7 2,613.0 2.55 261.061.4 +D+L 0.00.0 Length = 14.080 ft 1 0.499 0.321 1.00 1.001 1.001.00 1.00 14.90 1,449.5 2,903.4 3.87 290.093.0 46 Wood Beam LIC# : KW-06017148, Build:20.24.10.30 CASTILLO ENGINEERING INC.(c) ENERCALC, LLC 1982-2025 DESCRIPTION:B4 Overstrength Project File: 25-181.ec6 Project Title: Engineer: Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00+D+Lr 1.001 1.001.00 1.00 0.0 0.00 0.00.0 Length = 14.080 ft 1 0.417 0.283 1.25 1.001 1.001.00 1.00 15.58 1,514.9 3,629.2 4.27 362.5102.7 +D+0.750Lr+0.750L 0.00.0 Length = 14.080 ft 1 0.483 0.320 1.25 1.001 1.001.00 1.00 18.01 1,752.0 3,629.2 4.82 362.5116.0 +D+0.750L 0.00.0 Length = 14.080 ft 1 0.395 0.255 1.15 1.001 1.001.00 1.00 13.57 1,319.7 3,338.9 3.54 333.585.1 +0.60D 0.00.0 Length = 14.080 ft 1 0.120 0.079 1.60 1.001 1.001.00 1.00 5.75 559.0 4,645.4 1.53 464.036.9 +1.203D+1.750E 0.00.0 Length = 14.080 ft 1 0.336 0.240 1.60 1.001 1.001.00 1.00 16.06 1,561.4 4,645.4 4.63 464.0111.5 +1.203D-1.750E 0.00.0 Length = 14.080 ft 1 0.162 0.106 1.60 1.001 1.001.00 1.00 7.74 753.1 4,645.4 2.05 464.049.3 +1.152D+0.750L+1.313E 0.00.0 Length = 14.080 ft 1 0.381 0.264 1.60 1.001 1.001.00 1.00 18.20 1,770.1 4,645.4 5.10 464.0122.6 +1.152D+0.750L-1.313E 0.00.0 Length = 14.080 ft 1 0.255 0.159 1.60 1.001 1.001.00 1.00 12.16 1,182.3 4,645.4 3.06 464.073.6 +0.3970D+1.750E 0.00.0 Length = 14.080 ft 1 0.187 0.134 1.60 1.001 1.001.00 1.00 8.94 869.1 4,645.4 2.57 464.061.9 +0.3970D-1.750E 0.00.0 Length = 14.080 ft 1 0.047 0.045 1.60 1.001 1.001.00 1.00 2.22 216.0 4,645.4 0.87 464.020.8 . LocationLoad CombinationMax.LocationLoad CombinationSpan Max. Overall Maximum Deflections "-" Defl in Span in Span"+" Defl +D+0.750Lr+0.750L1 6.886 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 5.245 4.577 Max Upward from Load Combinations 5.245 4.577 Max Upward from Load Cases 2.787 2.453 Max Downward from all Load Conditions (Resisting Uplift)-0.892 -0.304 Max Downward from Load Cases (Resisting Uplift)-0.892 -0.304 D Only 2.787 2.453 +D+L 4.311 3.977 +D+Lr 4.540 3.761 +D+0.750Lr+0.750L 5.245 4.577 +D+0.750L 3.930 3.596 +0.60D 1.672 1.472 +D+0.70E 3.411 2.666 +D-0.70E 2.163 2.241 +D+0.750L+0.5250E 4.398 3.756 +D+0.750L-0.5250E 3.461 3.436 +0.60D+0.70E 2.297 1.685 +0.60D-0.70E 1.048 1.259 Lr Only 1.753 1.308 L Only 1.523 1.523 E Only 0.892 0.304 E Only * -1.0 -0.892 -0.304 47 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet Tag Beam 5 L =3.75 ft Member=4x12 A =39.38 in^2 S =73.8 in^3 No. of members=1 I =415.3 in^4 CD=1.00 E =1,600,000 psi CF=1.10 Va =4.725 kips CV=1.00 Ma =5.537 k-ft Cr=1.00 Total Load L/n=240 Live Load L/n=360 L=3.75 ft 0.60 0.60 Uniform load (W1) D L Trib w1,1 (15 +20)x 0 =0 +0 w1,2 (16 +0)x 0 =0 +0 w1,3 (15 +40)x 1 =15 +40 w1,4 (15 +60)x 3.5 =52.5 +210 w1,5 (5 +20)x 0 =0 +0 W1 =67.5 +250 =0.318 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 3.75 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (+)x 0 x 0 =0 +0 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =0 +0 =0.00 kips 0 3.75 Shear R1=0.595 kips R2=-0.595 kips Stress Ratio Vmax=0.60 kips Vallow.=4.73 x 1 =4.725 kips OK .13 Flexure M=0.558 k-ft Mallow.=6.09 x 1 =6.0908 k-ft OK .09 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.002 +0.000 +0.000 +0.000 =0.00 =L <L OK deflection:.01 21165 240 0.002 +0 D (L Only)=0.002 +0 +0 +0 =0 =L L OK deflection:.01 26880 360 USE:1- 4X12 shear: 2/10/25 12:00 AM B5 0 0 0 flexure: 0 0 48 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet Tag Beam 5 L =4.16 ft Member=4x12 A =39.38 in^2 S =73.8 in^3 No. of members=1 I =415.3 in^4 CD=1.00 E =1,600,000 psi CF=1.10 Va =4.725 kips CV=1.00 Ma =5.537 k-ft Cr=1.00 Total Load L/n=240 Live Load L/n=360 L=4.16 ft 0.22 0.22 Uniform load (W1) D L Trib w1,1 (15 +20)x 0 =0 +0 w1,2 (10 +0)x 5 =50 +0 w1,3 (15 +40)x 1 =15 +40 w1,4 (15 +60)x 0 =0 +0 w1,5 (5 +20)x 0 =0 +0 W1 =65 +40 =0.105 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 4.16 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (+)x 0 x 0 =0 +0 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =0 +0 =0.00 kips 0 4.16 Shear R1=0.218 kips R2=-0.218 kips Stress Ratio Vmax=0.22 kips Vallow.=4.73 x 1 =4.725 kips OK .05 Flexure M=0.227 k-ft Mallow.=6.09 x 1 =6.0908 k-ft OK .04 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.001 +0.000 +0.000 +0.000 =0.00 =L <L OK deflection:.01 46881 240 0.001 +0 D (L Only)=4E-04 +0 +0 +0 =0 =L L OK deflection:.00 123062 360 USE:1- 4X12 shear: 2/10/25 12:00 AM B6 0 0 0 flexure: 0 0 49 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet Tag Beam 5 L =3.50 ft Member=4x12 A =39.38 in^2 S =73.8 in^3 No. of members=1 I =415.3 in^4 CD=1.00 E =1,600,000 psi CF=1.10 Va =4.725 kips CV=1.00 Ma =5.537 k-ft Cr=1.00 Total Load L/n=240 Live Load L/n=360 L=3.5 ft 0.29 0.29 Uniform load (W1) D L Trib w1,1 (15 +20)x 0 =0 +0 w1,2 (10 +0)x 5 =50 +0 w1,3 (15 +40)x 2.08 =31.2 +83.2 w1,4 (15 +60)x 0 =0 +0 w1,5 (5 +20)x 0 =0 +0 W1 =81.2 +83.2 =0.164 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 3.5 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (+)x 0 x 0 =0 +0 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =0 +0 =0.00 kips 0 3.5 Shear R1=0.288 kips R2=-0.288 kips Stress Ratio Vmax=0.29 kips Vallow.=4.73 x 1 =4.725 kips OK .06 Flexure M=0.252 k-ft Mallow.=6.09 x 1 =6.0908 k-ft OK .04 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.001 +0.000 +0.000 +0.000 =0.00 =L <L OK deflection:.00 50276 240 8E-04 +0 D (L Only)=4E-04 +0 +0 +0 =0 =L L OK deflection:.00 99343 360 USE:1- 4X12 shear: 2/10/25 12:00 AM B7 0 0 0 flexure: 0 0 50 Wood Beam LIC# : KW-06017148, Build:20.23.10.31 CASTILLO ENGINEERING INC.(c) ENERCALC INC 1983-2023 DESCRIPTION:B8 Project File: 24-181.ec6 Project Title:Engineer: CODE REFERENCES Calculations per NDS 2024, IBC 2024, ASCE 7-22 Load Combination Set : ASCE 7-22 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 900 900 1350 625 1600 580 180 575 31.21 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-22 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.0150, L = 0.040 ksf, Tributary Width = 1.330 ft, (FLOOR) Uniform Load : D = 0.010 ksf, Extent = 4.160 -->> 7.660 ft, Tributary Width = 8.0 ft, (WALL) Point Load : D = 0.0810, L = 0.2181 k @ 4.160 ft, (B7) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.224: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 4.165 ft 19.71 psi= = 990.00 psi 4x12Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 180.00 psi== Section used for this span 4x12 Maximum Shear Stress Ratio 0.109 : 1 6.737 ft= = 222.11 psi Maximum Deflection 0 <360 4622Ratio =0 <240 Max Downward Transient Deflection 0.012 in 7977Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.020 in Ratio =>=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only n/a Span: 1 : +D+L n/a .Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1 0.103 0.057 0.90 1.100 1.001.00 1.00 0.57 92.0 891.0 0.24 162.09.3 0.00.0 1 0.224 0.109 1.00 1.100 1.001.00 1.00 1.37 222.1 990.0 0.52 180.019.7 0.00.0 1 0.153 0.076 1.25 1.100 1.001.00 1.00 1.17 189.6 1,237.5 0.45 225.017.1 0.00.0 1 0.035 0.019 1.60 1.100 1.001.00 1.00 0.34 55.2 1,584.0 0.15 288.05.6 . 51 Wood Beam LIC# : KW-06017148, Build:20.23.10.31 CASTILLO ENGINEERING INC.(c) ENERCALC INC 1983-2023 DESCRIPTION:B8 Project File: 24-181.ec6 Project Title:Engineer: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+L 1 0.0199 3.942 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.481 0.659 Max Upward from Load Combinations 0.481 0.659 Max Upward from Load Cases 0.303 0.336 D Only 0.177 0.336 +D+L 0.481 0.659 +D+0.750L 0.405 0.578 +0.60D 0.106 0.202 L Only 0.303 0.322 52 Wood Beam LIC# : KW-06017148, Build:20.23.10.31 CASTILLO ENGINEERING INC.(c) ENERCALC INC 1983-2023 DESCRIPTION:B9 Project File: 24-181.ec6 Project Title:Engineer: CODE REFERENCES Calculations per NDS 2024, IBC 2024, ASCE 7-22 Load Combination Set : ASCE 7-22 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.1 1350 1350 925 625 1600 580 170 675 31.21 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-22 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load : D = 0.0150, L = 0.040 ksf, Extent = 0.0 -->> 3.50 ft, Tributary Width = 2.080 ft, (FLOOR) Point Load : D = 0.1770, L = 0.3030 k @ 3.50 ft, (B8) Uniform Load : D = 0.0150, L = 0.040 ksf, Extent = 3.50 -->> 11.410 ft, Tributary Width = 3.750 ft, (FLOOR) Point Load : D = 0.1636, L = 0.4363 k @ 6.910 ft, (B5) Uniform Load : D = 0.0150, L = 0.040 ksf, Extent = 6.910 -->> 11.410 ft, Tributary Width = 1.750 ft, (FLOOR) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.431: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 6.788 ft 40.22 psi= = 1,350.00 psi 6x12Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 170.00 psi== Section used for this span 6x12 Maximum Shear Stress Ratio 0.237 : 1 10.452 ft= = 581.43 psi Maximum Deflection 0 <360 1130Ratio =0 <240 Max Downward Transient Deflection 0.086 in 1586Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.121 in Ratio =>=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only n/a Span: 1 : +D+L n/a .Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1 0.136 0.074 0.90 1.000 1.001.00 1.00 1.67 165.2 1,215.0 0.48 153.011.3 0.00.0 1 0.431 0.237 1.00 1.000 1.001.00 1.00 5.87 581.4 1,350.0 1.70 170.040.2 0.00.0 1 0.283 0.155 1.25 1.000 1.001.00 1.00 4.82 477.3 1,687.5 1.39 212.533.0 53 Wood Beam LIC# : KW-06017148, Build:20.23.10.31 CASTILLO ENGINEERING INC.(c) ENERCALC INC 1983-2023 DESCRIPTION:B9 Project File: 24-181.ec6 Project Title:Engineer: Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00+0.60D 1.000 1.001.00 1.00 0.0 0.00 0.00.0 1 0.046 0.025 1.60 1.000 1.001.00 1.00 1.00 99.1 2,160.0 0.29 272.06.8 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+L 1 0.1211 5.830 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 1.559 1.986 Max Upward from Load Combinations 1.559 1.986 Max Upward from Load Cases 1.102 1.430 D Only 0.457 0.556 +D+L 1.559 1.986 +D+0.750L 1.284 1.628 +0.60D 0.274 0.333 L Only 1.102 1.430 54 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet Tag Beam 5 L =11.41 ft Member=3.5x11.875 PSL A =41.56 in^2 S =82.3 in^3 No. of members=1 I =488.4 in^4 CD=1.00 E =2,000,000 psi CF=1.00 Va =8.035 kips CV=1.00 Ma =19.879 k-ft Cr=1.00 Total Load L/n=240 Live Load L/n=360 L=11.41 ft 2.98 2.98 Uniform load (W1) D L Trib w1,1 (15 +20)x 11.3 =168.75 +225 w1,2 (16 +0)x 8 =128 +0 w1,3 (15 +40)x 0 =0 +0 w1,4 (15 +60)x 0 =0 +0 w1,5 (5 +20)x 0 =0 +0 W1 =296.75 +225 =0.522 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 11.41 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (+)x 0 x 0 =0 +0 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =0 +0 =0.00 kips 0 11.41 Shear R1=2.977 kips R2=-2.977 kips Stress Ratio Vmax=2.98 kips Vallow.=8.04 x 1 =8.0354 kips OK .37 Flexure M=8.491 k-ft Mallow.=19.90 x 1 =19.902 k-ft OK .43 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.204 +0.000 +0.000 +0.000 =0.20 =L <L OK deflection:.36 672 240 0.204 +0 D (L Only)=0.088 +0 +0 +0 =0.09 =L L OK deflection:.23 1559 360 USE:1- 3.5X11.875 PSL shear: 2/10/25 12:00 AM B10 0 0 0 flexure: 0 0 55 CASTILLO ENGINEERING INC.Project KEMP ST 1205 Pine Avenue, Suite 201 Long Beach, CA 90813 Engr.Date:Job No.25-181 Sheet Elements Supporting Discontinuous Walls or Frames (ASCE 7-16, Section 12.3.3.3) Tag Load Combination with Overstrength (ASCE7-05 Section 12.4.3.3) Case:6a :1.105 D +0.75 L +-1.88 E Beam Member=3.5x11.875 PSL L =11.41 ft No. of members=1 A =41.56 in^2 CD=1.60 S =82.3 in^3 CF=1.00 Va =8.035 kips CV=1.00 Ma =19.879 k-ft MOD FACTOR1.20 Seismic load (PE1,PE2,PE3,PE4) v h Wo location (ft) E1 =134 x 8 x -1.88 =2.01 kips UP 5.167 PE2 =134 x 8 x -1.88 =-2.01 kips DOWN 0 PE3 =0 x 8 x -1.88 =0.00 kips PE4 =0 x 8 x -1.88 =0.00 kips Uniform load (w1) D L Trib w1,1 (15 +20)x 11.3 =169.5 +226 w1,2 (16 +0)x 8 =128 +0 w1,3 (+)x 0 =0 +0 w1,4 (+)x 0 =0 +0 w1,5 (+)x 0 =0 +0 w1 =297.5 +226 =0.524 klf factored w1=1.105 x 297.5 +0.75 x 226 =0.498 klf Point Load (P1) D L Trib.1 Trib.2 p1,1 (+)x 0 x 0 =0 +0 p1,2 (+)x 0 x 0 =0 +0 p1,3 (+)x 0 x 0 =0 +0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 P1 =0 +0 =0 kips 11.41 location (ft) factored P1=1.105 x 0 +0.75 x 0 =0.00 kips 0 ft Point Load (P2) D L Trib.1 Trib.2 p2,1 (+)x 0 x 0 =0 +0 p2,2 (+)x 0 x 0 =0 +0 p2,4 (+)x 0 x 0 =0 +0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 P2 =0 +0 =0.00 kips 11.41 location (ft) factored P2=1.105 x 0 +0.75 x 0 =0.00 kips 0 Shear CD ** Factor per ASCE7-16 12.4.3.3 R1=1.93 kips Vallow.=8.035 1.60 1.20 =15.4 R2=-3.75 kips Stress Ratio Vmax=3.94 kips Vallow.=15.43 x 1 =15.43 kips OK shear:.26 Flexure CD CF Cv * Mallow.=19.879 1.60 1.00 1.00 1.20 =38.2 M=13.67 k-ft Mallow.=38.21 x 1 =38.21 k-ft OK flexure:.36 USE:1- 3.5x11.875 PSL B10 6/9/25 12:00 AM 56 Wood Beam LIC# : KW-06017148, Build:20.23.10.31 CASTILLO ENGINEERING INC.(c) ENERCALC INC 1983-2023 DESCRIPTION:B11. Project File: 24-181.ec6 Project Title:Engineer: CODE REFERENCES Calculations per NDS 2024, IBC 2024, ASCE 7-22 Load Combination Set : ASCE 7-22 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist Parallam PSL 2.0E 2,900.0 2,900.0 2,900.0 750.0 2,000.0 1,016.54 290.0 2,025.0 45.070 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-22 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load : D = 0.0150, Lr = 0.020 ksf, Extent = 1.750 -->> 18.410 ft, Tributary Width = 2.0 ft, (ROOF) Uniform Load : D = 0.0160 ksf, Extent = 1.750 -->> 11.410 ft, Tributary Width = 8.0->10.660 ft, (WALL) Uniform Load : D = 0.0160 ksf, Extent = 11.410 -->> 18.410 ft, Tributary Width = 10.660->9.750 ft, (WALL) Uniform Load : D = 0.0150, Lr = 0.020 ksf, Extent = 1.750 -->> 18.410 ft, Tributary Width = 0.750 ft, (LOW ROOF) Uniform Load : D = 0.0150, L = 0.040 ksf, Extent = 1.750 -->> 18.410 ft, Tributary Width = 7.830 ft, (FLOOR) Point Load : D = 2.560, Lr = 1.932, L = 0.2160 k @ 2.0 ft, (B12) Point Load : D = 0.02150, Lr = 0.02857 k @ 2.0 ft, (HB1) Load for Span Number 2 Uniform Load : D = 0.0150, Lr = 0.020 ksf, Tributary Width = 2.0 ft, (ROOF) Uniform Load : D = 0.0160 ksf, Extent = 0.0 -->> 3.830 ft, Tributary Width = 9.750->8.0 ft, (WALL) Uniform Load : D = 0.0150, L = 0.040 ksf, Tributary Width = 0.670 ft, (FLOOR) Point Load : D = 1.350, L = 3.60 k @ 3.580 ft, (B1) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.345: 1 Load Combination +D+L+H Span # where maximum occurs Span # 1 Location of maximum on span 7.199 ft 78.51 psi= = 2,903.37 psi 10.50 X 11.875Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L+H = = = 290.00 psi== Section used for this span 10.50 X 11.875 Maximum Shear Stress Ratio 0.271 : 1 17.484 ft= = 1,001.95 psi Maximum Deflection 1706 >=360 525Ratio =538 >=240 Max Downward Transient Deflection 0.118 in 1878Ratio =>=360 Max Upward Transient Deflection -0.054 in Ratio = Max Downward Total Deflection 0.421 in Ratio =>=240 Max Upward Total Deflection -0.170 in fb: Actual F'b fv: Actual F'v Span: 2 : L Only Span: 2 : Lr Only Span: 1 : +D+0.750Lr+0.750L+H Span: 2 : +D+Lr+H . 57 Wood Beam LIC# : KW-06017148, Build:20.23.10.31 CASTILLO ENGINEERING INC.(c) ENERCALC INC 1983-2023 DESCRIPTION:B11. Project File: 24-181.ec6 Project Title:Engineer: Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu +D+H 0.0 0.00 0.00.0 1 0.244 0.198 0.90 1.001 1.001.00 1.00 13.12 638.1 2,613.0 4.29 261.051.6 2 0.114 0.198 0.90 1.001 1.001.00 1.00 6.13 298.3 2,613.0 1.86 261.051.6 0.00.0 1 0.345 0.271 1.00 1.001 1.001.00 1.00 20.60 1,002.0 2,903.4 6.53 290.078.5 2 0.322 0.271 1.00 1.001 1.001.00 1.00 19.22 934.5 2,903.4 5.53 290.078.5 0.00.0 1 0.235 0.214 1.25 1.001 1.001.00 1.00 17.55 853.6 3,629.2 6.44 362.577.5 2 0.086 0.214 1.25 1.001 1.001.00 1.00 6.43 312.5 3,629.2 1.97 362.577.5 0.00.0 1 0.191 0.155 1.15 1.001 1.001.00 1.00 13.12 638.1 3,338.9 4.29 333.551.6 2 0.089 0.155 1.15 1.001 1.001.00 1.00 6.13 298.3 3,338.9 1.86 333.551.6 0.00.0 1 0.296 0.242 1.25 1.001 1.001.00 1.00 22.07 1,073.0 3,629.2 7.29 362.587.6 2 0.217 0.242 1.25 1.001 1.001.00 1.00 16.17 786.2 3,629.2 4.70 362.587.6 0.00.0 1 0.273 0.206 1.15 1.001 1.001.00 1.00 18.73 910.9 3,338.9 5.70 333.568.6 2 0.232 0.206 1.15 1.001 1.001.00 1.00 15.95 775.5 3,338.9 4.62 333.568.6 0.00.0 1 0.137 0.111 1.60 1.001 1.001.00 1.00 13.12 638.1 4,645.4 4.29 464.051.6 2 0.064 0.111 1.60 1.001 1.001.00 1.00 6.13 298.3 4,645.4 1.86 464.051.6 0.00.0 1 0.231 0.189 1.60 1.001 1.001.00 1.00 22.07 1,073.0 4,645.4 7.29 464.087.6 2 0.169 0.189 1.60 1.001 1.001.00 1.00 16.17 786.2 4,645.4 4.70 464.087.6 0.00.0 1 0.196 0.148 1.60 1.001 1.001.00 1.00 18.73 910.9 4,645.4 5.70 464.068.6 2 0.167 0.148 1.60 1.001 1.001.00 1.00 15.95 775.5 4,645.4 4.62 464.068.6 0.00.0 1 0.082 0.067 1.60 1.001 1.001.00 1.00 7.87 382.9 4,645.4 2.58 464.031.0 2 0.039 0.067 1.60 1.001 1.001.00 1.00 3.68 179.0 4,645.4 1.11 464.031.0 0.00.0 1 0.137 0.111 1.60 1.001 1.001.00 1.00 13.12 638.1 4,645.4 4.29 464.051.6 2 0.064 0.111 1.60 1.001 1.001.00 1.00 6.13 298.3 4,645.4 1.86 464.051.6 0.00.0 1 0.196 0.148 1.60 1.001 1.001.00 1.00 18.73 910.9 4,645.4 5.70 464.068.6 2 0.167 0.148 1.60 1.001 1.001.00 1.00 15.95 775.5 4,645.4 4.62 464.068.6 0.00.0 1 0.082 0.067 1.60 1.001 1.001.00 1.00 7.87 382.9 4,645.4 2.58 464.031.0 2 0.039 0.067 1.60 1.001 1.001.00 1.00 3.68 179.0 4,645.4 1.11 464.031.0 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+0.750Lr+0.750L+0.450W+H 1 0.4207 8.434 0.0000 0.000 2 0.0000 8.434 -0.1705 3.830 . Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 7.285 12.858 Max Upward from Load Combinations 7.285 12.858 Max Upward from Load Cases 4.293 7.294 58 Wood Beam LIC# : KW-06017148, Build:20.23.10.31 CASTILLO ENGINEERING INC.(c) ENERCALC INC 1983-2023 DESCRIPTION:B11. Project File: 24-181.ec6 Project Title:Engineer: Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS +D+H 4.293 5.564 +D+L+H 6.136 12.858 +D+Lr+H 6.440 6.448 +D+S+H 4.293 5.564 +D+0.750Lr+0.750L+H 7.285 11.698 +D+0.750L+0.750S+H 5.675 11.035 +D+0.60W+H 4.293 5.564 +D+0.750Lr+0.750L+0.450W+H 7.285 11.698 +D+0.750L+0.750S+0.450W+H 5.675 11.035 +0.60D+0.60W+0.60H 2.576 3.339 +D+0.70E+0.60H 4.293 5.564 +D+0.750L+0.750S+0.5250E+H 5.675 11.035 +0.60D+0.70E+H 2.576 3.339 D Only 4.293 5.564 Lr Only 2.146 0.884 L Only 1.843 7.294 H Only 59 Wood Beam LIC# : KW-06017148, Build:20.24.10.30 CASTILLO ENGINEERING INC.(c) ENERCALC, LLC 1982-2025 DESCRIPTION:B11. Overstrength Project File: 25-181.ec6 Project Title: Engineer: CODE REFERENCES Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist Parallam PSL 2.0E 2,900.0 2,900.0 2,900.0 750.0 2,000.0 1,016.54 290.0 2,025.0 45.070 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load : D = 0.0150, Lr = 0.020 ksf, Extent = 1.750 -->> 18.410 ft, Tributary Width = 2.0 ft, (ROOF) Uniform Load : D = 0.0160 ksf, Extent = 1.750 -->> 11.410 ft, Tributary Width = 8.0->10.660 ft, (WALL) Uniform Load : D = 0.0160 ksf, Extent = 11.410 -->> 18.410 ft, Tributary Width = 10.660->9.750 ft, (WALL) Uniform Load : D = 0.0150, Lr = 0.020 ksf, Extent = 1.750 -->> 18.410 ft, Tributary Width = 0.750 ft, (LOW ROOF) Uniform Load : D = 0.0150, L = 0.040 ksf, Extent = 1.750 -->> 18.410 ft, Tributary Width = 7.830 ft, (FLOOR) Point Load : D = 2.560, Lr = 1.932, L = 0.2160 k @ 2.0 ft, (B12) Point Load : D = 0.02150, Lr = 0.02857 k @ 2.0 ft, (HB1) Point Load : E = 1.180 k @ 2.0 ft, (X1) Point Load : E = 1.670 k @ 9.250 ft, (Y1) Load for Span Number 2 Uniform Load : D = 0.0150, Lr = 0.020 ksf, Tributary Width = 2.0 ft, (ROOF) Uniform Load : D = 0.0160 ksf, Extent = 0.0 -->> 3.830 ft, Tributary Width = 9.750->8.0 ft, (WALL) Uniform Load : D = 0.0150, L = 0.040 ksf, Tributary Width = 0.670 ft, (FLOOR) Point Load : D = 1.350, L = 3.60 k @ 3.580 ft, (B1) Point Load : E = -1.670 k @ 3.580 ft, (Y1) . 60 Wood Beam LIC# : KW-06017148, Build:20.24.10.30 CASTILLO ENGINEERING INC.(c) ENERCALC, LLC 1982-2025 DESCRIPTION:B11. Overstrength Project File: 25-181.ec6 Project Title: Engineer: DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.438: 1 Load Combination +D+L+H, LL Comb Run (L*) Span # where maximum occurs Span # 1 Location of maximum on span 8.331 ft 82.37 psi= = 2,903.37 psi 10.50 X 11.875Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L+H, LL Comb Run (L*) = = = 290.00 psi== Section used for this span 10.50 X 11.875 Maximum Shear Stress Ratio 0.284 : 1 0.000 ft= = 1,270.62 psi Maximum Deflection 422 >=360 372 Ratio =256 >=240 Max Downward Transient Deflection 0.217 in 468 Ratio =>=360 Max Upward Transient Deflection -0.196 in Ratio = Max Downward Total Deflection 0.593 in Ratio =>=240 Max Upward Total Deflection -0.357 in fb: Actual F'b fv: Actual F'v Span: 2 : L Only, LL Comb Run (*L) Span: 2 : E Only Span: 1 : +D+0.750L+0.750S+0.5250E+H, LL Comb Run (L*) Span: 2 : +D+0.750L+0.750S+0.5250E+H, LL Comb Run (L*) .Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu +D+H 0.0 0.00 0.00.0 Length = 18.410 ft 1 0.244 0.198 0.90 1.001 1.001.00 1.00 13.12 638.1 2,613.0 4.29 261.051.6 Length = 3.830 ft 2 0.114 0.198 0.90 1.001 1.001.00 1.00 6.13 298.3 2,613.0 1.86 261.051.6 +D+L+H, LL Comb Run (*L)0.00.0 Length = 18.410 ft 1 0.322 0.230 1.00 1.001 1.001.00 1.00 19.22 934.5 2,903.4 5.53 290.066.6 Length = 3.830 ft 2 0.322 0.230 1.00 1.001 1.001.00 1.00 19.22 934.5 2,903.4 5.53 290.066.6 +D+L+H, LL Comb Run (L*)0.00.0 Length = 18.410 ft 1 0.438 0.284 1.00 1.001 1.001.00 1.00 26.13 1,270.6 2,903.4 6.85 290.082.4 Length = 3.830 ft 2 0.103 0.284 1.00 1.001 1.001.00 1.00 6.13 298.3 2,903.4 1.86 290.082.4 +D+L+H, LL Comb Run (LL)0.00.0 Length = 18.410 ft 1 0.345 0.271 1.00 1.001 1.001.00 1.00 20.60 1,002.0 2,903.4 6.53 290.078.5 Length = 3.830 ft 2 0.322 0.271 1.00 1.001 1.001.00 1.00 19.22 934.5 2,903.4 5.53 290.078.5 +D+Lr+H, LL Comb Run (*L)0.00.0 Length = 18.410 ft 1 0.174 0.142 1.25 1.001 1.001.00 1.00 13.00 632.4 3,629.2 4.28 362.551.5 Length = 3.830 ft 2 0.086 0.142 1.25 1.001 1.001.00 1.00 6.43 312.5 3,629.2 1.97 362.551.5 +D+Lr+H, LL Comb Run (L*)0.00.0 Length = 18.410 ft 1 0.237 0.214 1.25 1.001 1.001.00 1.00 17.67 859.1 3,629.2 6.46 362.577.7 Length = 3.830 ft 2 0.082 0.214 1.25 1.001 1.001.00 1.00 6.13 298.3 3,629.2 1.86 362.577.7 +D+Lr+H, LL Comb Run (LL)0.00.0 Length = 18.410 ft 1 0.235 0.214 1.25 1.001 1.001.00 1.00 17.55 853.6 3,629.2 6.44 362.577.5 Length = 3.830 ft 2 0.086 0.214 1.25 1.001 1.001.00 1.00 6.43 312.5 3,629.2 1.97 362.577.5 +D+S+H 0.00.0 Length = 18.410 ft 1 0.191 0.155 1.15 1.001 1.001.00 1.00 13.12 638.1 3,338.9 4.29 333.551.6 Length = 3.830 ft 2 0.089 0.155 1.15 1.001 1.001.00 1.00 6.13 298.3 3,338.9 1.86 333.551.6 +D+0.750Lr+0.750L+H, LL Comb Run (*L)0.00.0 Length = 18.410 ft 1 0.217 0.156 1.25 1.001 1.001.00 1.00 16.17 786.2 3,629.2 4.70 362.556.5 Length = 3.830 ft 2 0.217 0.156 1.25 1.001 1.001.00 1.00 16.17 786.2 3,629.2 4.70 362.556.5 +D+0.750Lr+0.750L+H, LL Comb Run (L*)0.00.0 Length = 18.410 ft 1 0.351 0.260 1.25 1.001 1.001.00 1.00 26.19 1,273.3 3,629.2 7.83 362.594.2 Length = 3.830 ft 2 0.082 0.260 1.25 1.001 1.001.00 1.00 6.13 298.3 3,629.2 1.86 362.594.2 +D+0.750Lr+0.750L+H, LL Comb Run (LL)0.00.0 Length = 18.410 ft 1 0.296 0.242 1.25 1.001 1.001.00 1.00 22.07 1,073.0 3,629.2 7.29 362.587.6 Length = 3.830 ft 2 0.217 0.242 1.25 1.001 1.001.00 1.00 16.17 786.2 3,629.2 4.70 362.587.6 +D+0.750L+0.750S+H, LL Comb Run (*L)0.00.0 61 Wood Beam LIC# : KW-06017148, Build:20.24.10.30 CASTILLO ENGINEERING INC.(c) ENERCALC, LLC 1982-2025 DESCRIPTION:B11. Overstrength Project File: 25-181.ec6 Project Title: Engineer: Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00Length = 18.410 ft 1 0.232 0.166 1.15 1.001 1.001.00 1.00 15.95 775.5 3,338.9 4.62 333.555.5 Length = 3.830 ft 2 0.232 0.166 1.15 1.001 1.001.00 1.00 15.95 775.5 3,338.9 4.62 333.555.5 +D+0.750L+0.750S+H, LL Comb Run (L*)0.00.0 Length = 18.410 ft 1 0.333 0.224 1.15 1.001 1.001.00 1.00 22.85 1,111.3 3,338.9 6.21 333.574.7 Length = 3.830 ft 2 0.089 0.224 1.15 1.001 1.001.00 1.00 6.13 298.3 3,338.9 1.86 333.574.7 +D+0.750L+0.750S+H, LL Comb Run (LL)0.00.0 Length = 18.410 ft 1 0.273 0.206 1.15 1.001 1.001.00 1.00 18.73 910.9 3,338.9 5.70 333.568.6 Length = 3.830 ft 2 0.232 0.206 1.15 1.001 1.001.00 1.00 15.95 775.5 3,338.9 4.62 333.568.6 +D+0.60W+H 0.00.0 Length = 18.410 ft 1 0.137 0.111 1.60 1.001 1.001.00 1.00 13.12 638.1 4,645.4 4.29 464.051.6 Length = 3.830 ft 2 0.064 0.111 1.60 1.001 1.001.00 1.00 6.13 298.3 4,645.4 1.86 464.051.6 +D+0.750Lr+0.750L+0.450W+H, LL Comb Run (*L)0.00.0 Length = 18.410 ft 1 0.169 0.122 1.60 1.001 1.001.00 1.00 16.17 786.2 4,645.4 4.70 464.056.5 Length = 3.830 ft 2 0.169 0.122 1.60 1.001 1.001.00 1.00 16.17 786.2 4,645.4 4.70 464.056.5 +D+0.750Lr+0.750L+0.450W+H, LL Comb Run (L*)0.00.0 Length = 18.410 ft 1 0.274 0.203 1.60 1.001 1.001.00 1.00 26.19 1,273.3 4,645.4 7.83 464.094.2 Length = 3.830 ft 2 0.064 0.203 1.60 1.001 1.001.00 1.00 6.13 298.3 4,645.4 1.86 464.094.2 +D+0.750Lr+0.750L+0.450W+H, LL Comb Run (LL)0.00.0 Length = 18.410 ft 1 0.231 0.189 1.60 1.001 1.001.00 1.00 22.07 1,073.0 4,645.4 7.29 464.087.6 Length = 3.830 ft 2 0.169 0.189 1.60 1.001 1.001.00 1.00 16.17 786.2 4,645.4 4.70 464.087.6 +D+0.750L+0.750S+0.450W+H, LL Comb Run (*L)0.00.0 Length = 18.410 ft 1 0.167 0.120 1.60 1.001 1.001.00 1.00 15.95 775.5 4,645.4 4.62 464.055.5 Length = 3.830 ft 2 0.167 0.120 1.60 1.001 1.001.00 1.00 15.95 775.5 4,645.4 4.62 464.055.5 +D+0.750L+0.750S+0.450W+H, LL Comb Run (L*)0.00.0 Length = 18.410 ft 1 0.239 0.161 1.60 1.001 1.001.00 1.00 22.85 1,111.3 4,645.4 6.21 464.074.7 Length = 3.830 ft 2 0.064 0.161 1.60 1.001 1.001.00 1.00 6.13 298.3 4,645.4 1.86 464.074.7 +D+0.750L+0.750S+0.450W+H, LL Comb Run (LL)0.00.0 Length = 18.410 ft 1 0.196 0.148 1.60 1.001 1.001.00 1.00 18.73 910.9 4,645.4 5.70 464.068.6 Length = 3.830 ft 2 0.167 0.148 1.60 1.001 1.001.00 1.00 15.95 775.5 4,645.4 4.62 464.068.6 +0.60D+0.60W+0.60H 0.00.0 Length = 18.410 ft 1 0.082 0.067 1.60 1.001 1.001.00 1.00 7.87 382.9 4,645.4 2.58 464.031.0 Length = 3.830 ft 2 0.039 0.067 1.60 1.001 1.001.00 1.00 3.68 179.0 4,645.4 1.11 464.031.0 +1.203D+1.750E+0.60H 0.00.0 Length = 18.410 ft 1 0.376 0.234 1.60 1.001 1.001.00 1.00 35.94 1,747.5 4,645.4 9.03 464.0108.6 Length = 3.830 ft 2 0.032 0.234 1.60 1.001 1.001.00 1.00 3.08 149.9 4,645.4 1.25 464.0108.6 +1.203D-1.750E+0.60H 0.00.0 Length = 18.410 ft 1 0.187 0.134 1.60 1.001 1.001.00 1.00 17.84 867.6 4,645.4 5.16 464.062.0 Length = 3.830 ft 2 0.187 0.134 1.60 1.001 1.001.00 1.00 17.84 867.6 4,645.4 5.16 464.062.0 +1.152D+0.750L+0.750S+1.313E+H, LL Comb Run (*L)0.00.0 Length = 18.410 ft 1 0.264 0.190 1.60 1.001 1.001.00 1.00 25.17 1,224.2 4,645.4 7.31 464.088.0 Length = 3.830 ft 2 0.095 0.190 1.60 1.001 1.001.00 1.00 9.03 439.3 4,645.4 2.71 464.088.0 +1.152D+0.750L+0.750S+1.313E+H, LL Comb Run (L*)0.00.0 Length = 18.410 ft 1 0.419 0.253 1.60 1.001 1.001.00 1.00 40.04 1,947.1 4,645.4 9.76 464.0117.4 Length = 3.830 ft 2 0.009 0.253 1.60 1.001 1.001.00 1.00 0.84 40.9 4,645.4 0.59 464.0117.4 +1.152D+0.750L+0.750S+1.313E+H, LL Comb Run (LL)0.00.0 Length = 18.410 ft 1 0.368 0.239 1.60 1.001 1.001.00 1.00 35.11 1,707.2 4,645.4 9.23 464.0111.0 Length = 3.830 ft 2 0.095 0.239 1.60 1.001 1.001.00 1.00 9.03 439.3 4,645.4 2.71 464.0111.0 62 Wood Beam LIC# : KW-06017148, Build:20.24.10.30 CASTILLO ENGINEERING INC.(c) ENERCALC, LLC 1982-2025 DESCRIPTION:B11. Overstrength Project File: 25-181.ec6 Project Title: Engineer: Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00+1.152D+0.750L+0.750S-1.313E+H, LL Comb Run (*L)1.001 1.001.00 1.00 0.0 0.00 0.00.0 Length = 18.410 ft 1 0.259 0.184 1.60 1.001 1.001.00 1.00 24.73 1,202.5 4,645.4 7.09 464.085.3 Length = 3.830 ft 2 0.259 0.184 1.60 1.001 1.001.00 1.00 24.73 1,202.5 4,645.4 7.09 464.085.3 +1.152D+0.750L+0.750S-1.313E+H, LL Comb Run (L*)0.00.0 Length = 18.410 ft 1 0.156 0.125 1.60 1.001 1.001.00 1.00 14.91 725.3 4,645.4 4.82 464.057.9 Length = 3.830 ft 2 0.156 0.125 1.60 1.001 1.001.00 1.00 14.91 725.3 4,645.4 4.33 464.057.9 +1.152D+0.750L+0.750S-1.313E+H, LL Comb Run (LL)0.00.0 Length = 18.410 ft 1 0.259 0.184 1.60 1.001 1.001.00 1.00 24.73 1,202.5 4,645.4 7.09 464.085.3 Length = 3.830 ft 2 0.259 0.184 1.60 1.001 1.001.00 1.00 24.73 1,202.5 4,645.4 7.09 464.085.3 +0.3970D+1.750E+H 0.00.0 Length = 18.410 ft 1 0.270 0.144 1.60 1.001 1.001.00 1.00 25.77 1,252.9 4,645.4 5.57 464.067.0 Length = 3.830 ft 2 0.084 0.144 1.60 1.001 1.001.00 1.00 8.03 390.3 4,645.4 2.37 464.067.0 +0.3970D-1.750E+H 0.00.0 Length = 18.410 ft 1 0.165 0.095 1.60 1.001 1.001.00 1.00 15.74 765.6 4,645.4 3.66 464.044.0 Length = 3.830 ft 2 0.135 0.095 1.60 1.001 1.001.00 1.00 12.90 627.2 4,645.4 3.66 464.044.0 . LocationLoad CombinationMax.LocationLoad CombinationSpan Max. Overall Maximum Deflections "-" Defl in Span in Span"+" Defl +D+0.750L+0.750S+0.5250E+H, LL Comb Run (L*)1 9.051 0.0000 0.000 2 9.051 -0.3570 3.830 . Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 7.830 12.858 Max Upward from Load Combinations 7.830 12.858 Max Upward from Load Cases 4.293 7.294 Max Downward from all Load Conditions (Resisting Uplift)-2.207 -1.027 Max Downward from Load Cases (Resisting Uplift)-2.207 -1.027 +D+H 4.293 5.564 +D+L+H, LL Comb Run (*L)3.583 9.978 +D+L+H, LL Comb Run (L*)6.847 8.445 +D+L+H, LL Comb Run (LL)6.136 12.858 +D+Lr+H, LL Comb Run (*L)4.277 5.733 +D+Lr+H, LL Comb Run (L*)6.456 6.279 +D+Lr+H, LL Comb Run (LL)6.440 6.448 +D+S+H 4.293 5.564 +D+0.750Lr+0.750L+H, LL Comb Run (*L)3.748 9.001 +D+0.750Lr+0.750L+H, LL Comb Run (L*)7.830 8.261 +D+0.750Lr+0.750L+H, LL Comb Run (LL)7.285 11.698 +D+0.750L+0.750S+H, LL Comb Run (*L)3.760 8.874 +D+0.750L+0.750S+H, LL Comb Run (L*)6.208 7.725 +D+0.750L+0.750S+H, LL Comb Run (LL)5.675 11.035 +D+0.60W+H 4.293 5.564 +D+0.750Lr+0.750L+0.450W+H, LL Comb Run (*L)3.748 9.001 +D+0.750Lr+0.750L+0.450W+H, LL Comb Run (L*)7.830 8.261 +D+0.750Lr+0.750L+0.450W+H, LL Comb Run (LL)7.285 11.698 +D+0.750L+0.750S+0.450W+H, LL Comb Run (*L)3.760 8.874 +D+0.750L+0.750S+0.450W+H, LL Comb Run (L*)6.208 7.725 +D+0.750L+0.750S+0.450W+H, LL Comb Run (LL)5.675 11.035 +0.60D+0.60W+0.60H 2.576 3.339 +D+0.70E+0.60H 5.839 4.845 +D-0.70E+0.60H 2.748 6.284 +D+0.750L+0.750S+0.5250E+H, LL Comb Run (*L)4.919 8.335 +D+0.750L+0.750S+0.5250E+H, LL Comb Run (L*)7.367 7.185 +D+0.750L+0.750S+0.5250E+H, LL Comb Run (LL)6.834 10.495 63 Wood Beam LIC# : KW-06017148, Build:20.24.10.30 CASTILLO ENGINEERING INC.(c) ENERCALC, LLC 1982-2025 DESCRIPTION:B11. Overstrength Project File: 25-181.ec6 Project Title: Engineer: Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS +D+0.750L+0.750S-0.5250E+H, LL Comb Run (*L)2.601 9.414 +D+0.750L+0.750S-0.5250E+H, LL Comb Run (L*)5.050 8.264 +D+0.750L+0.750S-0.5250E+H, LL Comb Run (LL)4.517 11.574 +0.60D+0.70E+H 4.121 2.619 +0.60D-0.70E+H 1.031 4.058 D Only 4.293 5.564 Lr Only, LL Comb Run (*L)-0.016 0.169 Lr Only, LL Comb Run (L*)2.162 0.715 Lr Only, LL Comb Run (LL)2.146 0.884 L Only, LL Comb Run (*L)-0.711 4.413 L Only, LL Comb Run (L*)2.553 2.880 L Only, LL Comb Run (LL)1.843 7.294 E Only 2.207 -1.027 E Only * -1.0 -2.207 1.027 H Only 64 ARCHITECT CASTILLO ENGINEERING JOB 1147 E. MARKET STREET Long Beach, CA 90805 ENGR. MC DATE JOB NO. SHEET NO. NOTCH ON COMPRESSION FACE AT END 2.42 7.64 0.58 7.06 V 7285 lbs member type= 2x8 b=10.5 in viga Fv=psi d 11.875 in viga Cd= dn= 7.06 in F'v=psi e=9.00 in 'e' > 'dn', therefore use Eq.(3.4-2)slope=4 :12 support member width w= 3.5 in 2024 NDS Equation 3.4-5 fv= 2b = 3 x =psi < psi, therefore NA 2 x ## x 11.88 -- 7.06 x 9 Use Eq. (3.4-2) 2024 NDS Equation 3.4-2 fv= 1.5V =psi < psi, therefore Satisfactory (.51) b dn 7.25 7.06dn Rec'd= TAG: B11 181 w 3V d-(d-dn)/(dn)*e 290 10/02/2025 7.06 draftrer= 11.88 psl 290 1 290 7285 147 290 65 Wood Beam LIC# : KW-06017148, Build:20.23.10.31 CASTILLO ENGINEERING INC.(c) ENERCALC INC 1983-2023 DESCRIPTION:B12 Project File: 24-181.ec6 Project Title:Engineer: CODE REFERENCES Calculations per NDS 2024, IBC 2024, ASCE 7-22 Load Combination Set : ASCE 7-22 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist Parallam PSL 2.0E 2,900.0 2,900.0 2,900.0 750.0 2,000.0 1,016.54 290.0 2,025.0 45.070 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-22 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load : D = 0.0150, Lr = 0.020 ksf, Extent = 0.0 -->> 16.10 ft, Tributary Width = 11.250 ft, (ROOF) Uniform Load : D = 0.0160 ksf, Extent = 0.0 -->> 16.10 ft, Tributary Width = 8.0 ft, (WALL) Uniform Load : D = 0.0150, Lr = 0.020 ksf, Extent = 0.0 -->> 16.10 ft, Tributary Width = 0.750 ft, (LOW ROOF) Uniform Load : D = 0.0150, L = 0.040 ksf, Extent = 0.0 -->> 16.10 ft, Tributary Width = 0.670 ft, (FLOOR) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.485: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 8.050 ft 95.46 psi= = 3,629.22 psi 5.25x11.875Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 362.50 psi== Section used for this span 5.25x11.875 Maximum Shear Stress Ratio 0.263 : 1 15.160 ft= = 1,758.49 psi Maximum Deflection 0 <360 333Ratio =0 <240 Max Downward Transient Deflection 0.249 in 775Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.579 in Ratio =>=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1 0.384 0.208 0.90 1.001 1.001.00 1.00 10.31 1,002.2 2,613.0 2.26 261.054.4 0.00.0 1 0.374 0.203 1.00 1.001 1.001.00 1.00 11.17 1,086.7 2,903.4 2.45 290.059.0 0.00.0 1 0.485 0.263 1.25 1.001 1.001.00 1.00 18.08 1,758.5 3,629.2 3.97 362.595.5 0.00.0 66 Wood Beam LIC# : KW-06017148, Build:20.23.10.31 CASTILLO ENGINEERING INC.(c) ENERCALC INC 1983-2023 DESCRIPTION:B12 Project File: 24-181.ec6 Project Title:Engineer: Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00Length = 16.10 ft 1 0.450 0.245 1.25 1.001 1.001.00 1.00 16.79 1,632.8 3,629.2 3.68 362.588.6 0.00.0 1 0.319 0.173 1.15 1.001 1.001.00 1.00 10.96 1,065.6 3,338.9 2.40 333.557.8 0.00.0 1 0.129 0.070 1.60 1.001 1.001.00 1.00 6.18 601.3 4,645.4 1.36 464.032.6 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.5791 8.109 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 4.492 4.492 Max Upward from Load Combinations 4.492 4.492 Max Upward from Load Cases 2.560 2.560 D Only 2.560 2.560 +D+L 2.776 2.776 +D+Lr 4.492 4.492 +D+0.750Lr+0.750L 4.171 4.171 +D+0.750L 2.722 2.722 +0.60D 1.536 1.536 Lr Only 1.932 1.932 L Only 0.216 0.216 67 Wood Beam LIC# : KW-06017148, Build:20.24.10.30 CASTILLO ENGINEERING INC.(c) ENERCALC, LLC 1982-2025 DESCRIPTION:B12 Overstrength Project File: 25-181.ec6 Project Title: Engineer: CODE REFERENCES Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist Parallam PSL 2.0E 2,900.0 2,900.0 2,900.0 750.0 2,000.0 1,016.54 290.0 2,025.0 45.070 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load : D = 0.0150, Lr = 0.020 ksf, Extent = 0.0 -->> 16.10 ft, Tributary Width = 11.250 ft, (ROOF) Uniform Load : D = 0.0160 ksf, Extent = 0.0 -->> 16.10 ft, Tributary Width = 8.0 ft, (WALL) Uniform Load : D = 0.0150, Lr = 0.020 ksf, Extent = 0.0 -->> 16.10 ft, Tributary Width = 0.750 ft, (LOW ROOF) Uniform Load : D = 0.0150, L = 0.040 ksf, Extent = 0.0 -->> 16.10 ft, Tributary Width = 0.670 ft, (FLOOR) Point Load : E = 1.178 k @ 12.667 ft, (X1) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.485: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 8.050 ft 95.46 psi= = 3,629.22 psi 5.25x11.875Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 362.50 psi== Section used for this span 5.25x11.875 Maximum Shear Stress Ratio 0.263 : 1 15.160 ft= = 1,758.49 psi Maximum Deflection 775 >=360 333 Ratio =0 <240 Max Downward Transient Deflection 0.249 in 2599 Ratio =>=360 Max Upward Transient Deflection -0.074 in Ratio = Max Downward Total Deflection 0.579 in Ratio =>=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only Span: 1 : E Only * -1.0 Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 Length = 16.10 ft 1 0.384 0.208 0.90 1.001 1.001.00 1.00 10.31 1,002.2 2,613.0 2.26 261.054.4 +D+L 0.00.0 Length = 16.10 ft 1 0.374 0.203 1.00 1.001 1.001.00 1.00 11.17 1,086.7 2,903.4 2.45 290.059.0 68 Wood Beam LIC# : KW-06017148, Build:20.24.10.30 CASTILLO ENGINEERING INC.(c) ENERCALC, LLC 1982-2025 DESCRIPTION:B12 Overstrength Project File: 25-181.ec6 Project Title: Engineer: Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00+D+Lr 1.001 1.001.00 1.00 0.0 0.00 0.00.0 Length = 16.10 ft 1 0.485 0.263 1.25 1.001 1.001.00 1.00 18.08 1,758.5 3,629.2 3.97 362.595.5 +D+0.750Lr+0.750L 0.00.0 Length = 16.10 ft 1 0.450 0.245 1.25 1.001 1.001.00 1.00 16.79 1,632.8 3,629.2 3.68 362.588.6 +D+0.750L 0.00.0 Length = 16.10 ft 1 0.319 0.173 1.15 1.001 1.001.00 1.00 10.96 1,065.6 3,338.9 2.40 333.557.8 +0.60D 0.00.0 Length = 16.10 ft 1 0.129 0.070 1.60 1.001 1.001.00 1.00 6.18 601.3 4,645.4 1.36 464.032.6 +1.203D+1.750E 0.00.0 Length = 16.10 ft 1 0.339 0.225 1.60 1.001 1.001.00 1.00 16.19 1,574.4 4,645.4 4.34 464.0104.5 +1.203D-1.750E 0.00.0 Length = 16.10 ft 1 0.191 0.118 1.60 1.001 1.001.00 1.00 9.11 886.1 4,645.4 2.28 464.054.9 +1.152D+0.750L+1.313E 0.00.0 Length = 16.10 ft 1 0.321 0.206 1.60 1.001 1.001.00 1.00 15.32 1,489.9 4,645.4 3.96 464.095.4 +1.152D+0.750L-1.313E 0.00.0 Length = 16.10 ft 1 0.210 0.125 1.60 1.001 1.001.00 1.00 10.01 973.7 4,645.4 2.42 464.058.2 +0.3970D+1.750E 0.00.0 Length = 16.10 ft 1 0.176 0.131 1.60 1.001 1.001.00 1.00 8.39 816.4 4,645.4 2.52 464.060.6 +0.3970D-1.750E 0.00.0 Length = 16.10 ft 1 0.059 0.054 1.60 1.001 1.001.00 1.00 2.80 272.0 4,645.4 1.04 464.024.9 . LocationLoad CombinationMax.LocationLoad CombinationSpan Max. Overall Maximum Deflections "-" Defl in Span in Span"+" Defl +D+Lr1 8.109 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 4.492 4.492 Max Upward from Load Combinations 4.492 4.492 Max Upward from Load Cases 2.560 2.560 Max Downward from all Load Conditions (Resisting Uplift)-0.251 -0.927 Max Downward from Load Cases (Resisting Uplift)-0.251 -0.927 D Only 2.560 2.560 +D+L 2.776 2.776 +D+Lr 4.492 4.492 +D+0.750Lr+0.750L 4.171 4.171 +D+0.750L 2.722 2.722 +0.60D 1.536 1.536 +D+0.70E 2.736 3.209 +D-0.70E 2.384 1.912 +D+0.750L+0.5250E 2.854 3.209 +D+0.750L-0.5250E 2.590 2.236 +0.60D+0.70E 1.712 2.185 +0.60D-0.70E 1.360 0.887 Lr Only 1.932 1.932 L Only 0.216 0.216 E Only 0.251 0.927 E Only * -1.0 -0.251 -0.927 69 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet Tag Beam 5 L =7.00 ft Member=4x12 A =39.38 in^2 S =73.8 in^3 No. of members=1 I =415.3 in^4 CD=1.00 E =1,600,000 psi CF=1.10 Va =4.725 kips CV=1.00 Ma =5.537 k-ft Cr=1.00 Total Load L/n=240 Live Load L/n=360 L=7 ft 0.81 0.81 Uniform load (W1) D L Trib w1,1 (15 +20)x 2 =30 +40 w1,2 (16 +0)x 10 =160 +0 w1,3 (15 +40)x 0 =0 +0 w1,4 (15 +60)x 0 =0 +0 w1,5 (5 +20)x 0 =0 +0 W1 =190 +40 =0.230 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 7 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (+)x 0 x 0 =0 +0 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =0 +0 =0.00 kips 0 7 Shear R1=0.805 kips R2=-0.805 kips Stress Ratio Vmax=0.81 kips Vallow.=4.73 x 1 =4.725 kips OK .17 Flexure M=1.409 k-ft Mallow.=6.09 x 1 =6.0908 k-ft OK .23 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.019 +0.000 +0.000 +0.000 =0.02 =L <L OK deflection:.05 4492 240 0.019 +0 D (L Only)=0.003 +0 +0 +0 =0 =L L OK deflection:.01 25829 360 USE:1- 4X12 shear: 2/10/25 12:00 AM B13 0 0 0 flexure: 0 0 70 CASTILLO ENGINEERING INC.Project KEMP ST 1205 Pine Avenue, Suite 201 Long Beach, CA 90813 Engr.Date:Job No.25-181 Sheet Elements Supporting Discontinuous Walls or Frames (ASCE 7-16, Section 12.3.3.3) Tag Load Combination with Overstrength (ASCE7-05 Section 12.4.3.3) Case:5a :1.14 D +0 L +-2.50 E Beam Member=4X12 L =7 ft No. of members=1 A =39.38 in^2 CD=1.60 S =73.8 in^3 CF=1.10 Va =4.725 kips CV=1.00 Ma =5.537 k-ft MOD FACTOR1.20 Seismic load (PE1,PE2,PE3,PE4) v h Wo location (ft) E1 =136 x 8 x -2.50 =2.72 kips UP 4.75 PE2 =136 x 8 x -2.50 =-2.72 kips DOWN 0 PE3 =0 x 8 x -2.50 =0.00 kips PE4 =0 x 8 x -2.50 =0.00 kips Uniform load (w1) D L Trib w1,1 (15 +20)x 2 =30 +40 w1,2 (16 +0)x 10 =160 +0 w1,3 (+)x 0 =0 +0 w1,4 (+)x 0 =0 +0 w1,5 (+)x 0 =0 +0 w1 =190 +40 =0.230 klf factored w1=1.14 x 190 +0 x 40 =0.217 klf Point Load (P1) D L Trib.1 Trib.2 p1,1 (+)x 0 x 0 =0 +0 p1,2 (+)x 0 x 0 =0 +0 p1,3 (+)x 0 x 0 =0 +0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 P1 =0 +0 =0 kips 7 location (ft) factored P1=1.14 x 0 +0 x 0 =0.00 kips 0 ft Point Load (P2) D L Trib.1 Trib.2 p2,1 (+)x 0 x 0 =0 +0 p2,2 (+)x 0 x 0 =0 +0 p2,4 (+)x 0 x 0 =0 +0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 P2 =0 +0 =0.00 kips 7 location (ft) factored P2=1.14 x 0 +0 x 0 =0.00 kips 0 Shear CD ** Factor per ASCE7-16 12.4.3.3 R1=-1.09 kips Vallow.=4.725 1.60 1.20 =9.07 R2=-2.60 kips Stress Ratio Vmax=2.60 kips Vallow.=9.07 x 1 =9.07 kips OK shear:.29 Flexure CD CF Cv * Mallow.=5.537 1.60 1.10 1.00 1.20 =11.7 M=5.29 k-ft Mallow.=11.69 x 1 =11.69 k-ft OK flexure:.45 USE:1- 4X12 B13 6/9/25 12:00 AM 71 ARCHITECT CASTILLO ENGINEERING, INC.JOB 1012 N KEMP STREET 1147 E Market Street, Long Beach, CA 90805 ENGR. MC DATE JOB NO. 25-181 SHEET NO. HIP RIDGE BEAM DESIGN L=ft L1= ft w= ( + ) x /2 x 2 / (2)^.5 =+ =plf W=x x = k x 1 / 3 =k x 2 / 3 =k <k M= 2x x =k-ft <k-ft 9 x D=x (x 12 )^3 = in = 76.7 x x 3.5 x USE: 2.83 2.002015 (.03) 28 4921 2.83 0.07 19028 1.84 0.74 07/02/2025 2.00 0.02 2.80.07 0.5 (.01) (3)^.5 HB1 70 1600000 0.07 L 49 4x4 0.07 0.05 0.00 3.50 0.03 2.83 (.03) BEAM L1 L1 L w W V1 72 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet Tag Beam 5 L =3.00 ft Member=4x6 A =19.25 in^2 S =17.6 in^3 No. of members=1 I =48.5 in^4 CD=1.00 E =1,600,000 psi CF=1.30 Va =2.310 kips CV=1.00 Ma =1.323 k-ft Cr=1.00 Total Load L/n=240 Live Load L/n=360 L=3 ft 0.10 0.10 Uniform load (W1) D L Trib w1,1 (15 +20)x 1 =15 +20 w1,2 (16 +0)x 2 =32 +0 w1,3 (15 +40)x 0 =0 +0 w1,4 (15 +60)x 0 =0 +0 w1,5 (5 +20)x 0 =0 +0 W1 =47 +20 =0.067 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 3 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (+)x 0 x 0 =0 +0 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =0 +0 =0.00 kips 0 3 Shear R1=0.101 kips R2=-0.101 kips Stress Ratio Vmax=0.10 kips Vallow.=2.31 x 1 =2.31 kips OK .04 Flexure M=0.075 k-ft Mallow.=1.72 x 1 =1.7205 k-ft OK .04 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.002 +0.000 +0.000 +0.000 =0.00 =L <L OK deflection:.01 22890 240 0.002 +0 D (L Only)=5E-04 +0 +0 +0 =0 =L L OK deflection:.00 76683 360 USE:1- 4X6 shear: 2/10/25 12:00 AM H1 0 0 0 flexure: 0 0 73 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet Tag Beam 5 L =3.16 ft Member=4x6 A =19.25 in^2 S =17.6 in^3 No. of members=1 I =48.5 in^4 CD=1.00 E =1,600,000 psi CF=1.30 Va =2.310 kips CV=1.00 Ma =1.323 k-ft Cr=1.00 Total Load L/n=240 Live Load L/n=360 L=3.16 ft 0.17 0.17 Uniform load (W1) D L Trib w1,1 (15 +20)x 0 =0 +0 w1,2 (16 +0)x 2 =32 +0 w1,3 (15 +40)x 1.33 =19.95 +53.2 w1,4 (15 +60)x 0 =0 +0 w1,5 (5 +20)x 0 =0 +0 W1 =51.95 +53.2 =0.105 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 3.16 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (+)x 0 x 0 =0 +0 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =0 +0 =0.00 kips 0 3.16 Shear R1=0.166 kips R2=-0.166 kips Stress Ratio Vmax=0.17 kips Vallow.=2.31 x 1 =2.31 kips OK .07 Flexure M=0.131 k-ft Mallow.=1.72 x 1 =1.7205 k-ft OK .08 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.003 +0.000 +0.000 +0.000 =0.00 =L <L OK deflection:.02 12480 240 0.003 +0 D (L Only)=0.002 +0 +0 +0 =0 =L L OK deflection:.01 24667 360 USE:1- 4X6 shear: 2/10/25 12:00 AM H2 0 0 0 flexure: 0 0 74 Wood Beam LIC# : KW-06017148, Build:20.23.10.31 CASTILLO ENGINEERING INC.(c) ENERCALC INC 1983-2023 DESCRIPTION:(E)H1 Project File: 24-181.ec6 Project Title:Engineer: CODE REFERENCES Calculations per NDS 2024, IBC 2024, ASCE 7-22 Load Combination Set : ASCE 7-22 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist Parallam PSL 2.0E 2,900.0 2,900.0 2,900.0 750.0 2,000.0 1,016.54 290.0 2,025.0 45.070 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-22 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.0150, L = 0.040 ksf, Tributary Width = 2.250 ft, (FLOOR) Uniform Load : D = 0.0160 ksf, Tributary Width = 1.0 ft, (WALL) Point Load : D = 5.564, Lr = 0.8840, L = 7.294 k @ 1.0 ft, (B11) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.488: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 2.359 ft 54.13 psi= = 2,850.80 psi 3.5x14.0Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 290.00 psi== Section used for this span 3.5x14.0 Maximum Shear Stress Ratio 0.187 : 1 15.039 ft= = 1,391.29 psi Maximum Deflection 0 <360 530Ratio =0 <240 Max Downward Transient Deflection 0.218 in 890Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.366 in Ratio =>=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only n/a Span: 1 : +D+L n/a .Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1 0.229 0.081 0.90 0.983 1.001.00 1.00 5.60 587.5 2,565.7 0.69 261.021.1 0.00.0 1 0.488 0.187 1.00 0.983 1.001.00 1.00 13.26 1,391.3 2,850.8 1.77 290.054.1 0.00.0 1 0.189 0.063 1.25 0.983 1.001.00 1.00 6.43 674.4 3,563.5 0.75 362.522.8 0.00.0 1 0.351 0.130 1.25 0.983 1.001.00 1.00 11.91 1,250.1 3,563.5 1.54 362.547.1 0.00.0 75 Wood Beam LIC# : KW-06017148, Build:20.23.10.31 CASTILLO ENGINEERING INC.(c) ENERCALC INC 1983-2023 DESCRIPTION:(E)H1 Project File: 24-181.ec6 Project Title:Engineer: Maximum Forces & Stresses for Load Combinations Span #C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00Length = 16.160 ft 1 0.363 0.138 1.15 0.983 1.001.00 1.00 11.33 1,189.5 3,278.4 1.50 333.545.9 0.00.0 1 0.077 0.027 1.60 0.983 1.001.00 1.00 3.36 352.5 4,561.3 0.41 464.012.7 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+L 1 0.3657 7.372 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 13.192 1.925 Max Upward from Load Combinations 13.192 1.925 Max Upward from Load Cases 7.570 1.179 D Only 5.622 0.746 +D+L 13.192 1.925 +D+Lr 6.451 0.801 +D+0.750Lr+0.750L 11.921 1.671 +D+0.750L 11.299 1.630 +0.60D 3.373 0.448 Lr Only 0.829 0.055 L Only 7.570 1.179 76 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet 1.5ft 1.16ft Tag Beam 5 L =2.66 ft Member=4x10 A =32.38 in^2 S =49.9 in^3 No. of members=1 I =230.8 in^4 4.50 CD=1.00 E =1,600,000 psi CF=1.20 Va =3.885 kips CV=1.00 Ma =3.743 k-ft Cr=1.00 Total Load L/n=240 Live Load L/n=360 L=2.66 ft 2.67 3.25 Uniform load (W1) D L Trib w1,1 (15 +20)x 2 =30 +40 w1,2 (16 +0)x 2 =32 +0 w1,3 (15 +40)x 7.83 =117.45 +313.2 w1,4 (15 +60)x 0 =0 +0 w1,5 (5 +20)x 0 =0 +0 W1 =179.45 +353.2 =0.533 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 2.66 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (1227 +3272)x 1 x 1 =1227 +3272 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =1227 +3272 =4.50 kips 1.5 1.16 Shear R1=2.670 kips R2=-3.245 kips Stress Ratio Vmax=3.25 kips Vallow.=3.89 x 1 =3.885 kips OK .84 Flexure M=3.387 k-ft Mallow.=4.49 x 1 =4.492 k-ft OK .75 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.002 +0.000 +0.000 +0.008 =0.01 =L <L OK deflection:.07 3291 240 0.002 +0.008 D (L Only)=0.001 +0 +0 +0.00587394 =0.01 =L L OK deflection:.08 4592 360 USE:1- 4X10 shear: 2/10/25 12:00 AM (E)H2 0 0 0 flexure: 0 0 77 FOUNDATION KEYPLAN (E)CF1 5.52 K CF1 4.13 K CF2 4.52 K (E)CF3 5.12 K CF36.74 K F1 0.02 K F2 7.28 K F3 2.98 K 3.25 K F4 0.37 K F4 0.37 K F5 2.98 K 0.81 KB1B1 B2B2 F6 0.42 K 0.37 K 1.55 K 0.22 K F7 0.42 K F8 0.81 K 0.65 K F9 5.24 K F10 1.98 K F11 7.51 K F14 1.92 K F15 13.19 K FJ1 F12 0.60 K F13 0.42 K (E)CF2 3.32 K F17 4.57 K 1.40 K F16 4.76 K 1.40 K 78 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet Tag Beam 5 L =3.25 ft Member=2x6 A =8.25 in^2 S =7.6 in^3 No. of members=1 I =20.8 in^4 CD=1.00 E =1,600,000 psi CF=1.30 Va =0.990 kips CV=1.00 Ma =0.567 k-ft Cr=1.15 Total Load L/n=240 Live Load L/n=360 L=3.25 ft 0.12 0.12 Uniform load (W1) D L Trib w1,1 (15 +20)x 0 =0 +0 w1,2 (16 +0)x 0 =0 +0 w1,3 (15 +40)x 1.33 =19.95 +53.2 w1,4 (15 +60)x 0 =0 +0 w1,5 (5 +20)x 0 =0 +0 W1 =19.95 +53.2 =0.073 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 3.25 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (+)x 0 x 0 =0 +0 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =0 +0 =0.00 kips 0 3.25 Shear R1=0.119 kips R2=-0.119 kips Stress Ratio Vmax=0.12 kips Vallow.=0.99 x 1 =0.99 kips OK .12 Flexure M=0.097 k-ft Mallow.=0.85 x 1 =0.8479 k-ft OK .11 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.006 +0.000 +0.000 +0.000 =0.01 =L <L OK deflection:.03 7067 240 0.006 +0 D (L Only)=0.004 +0 +0 +0 =0 =L L OK deflection:.04 9718 360 USE:1- 2X6 flexure: 0 0 shear: 2/10/25 12:00 AM FJ1 0 0 0 79 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet Tag Beam 5 L =3.58 ft Member=4x12 A =39.38 in^2 S =73.8 in^3 No. of members=1 I =415.3 in^4 CD=1.00 E =1,600,000 psi CF=1.10 Va =4.725 kips CV=1.00 Ma =5.537 k-ft Cr=1.00 Total Load L/n=240 Live Load L/n=360 L=3.58 ft 0.42 0.42 Uniform load (W1) D L Trib w1,1 (15 +20)x 0 =0 +0 w1,2 (16 +0)x 0 =0 +0 w1,3 (15 +40)x 1.58 =23.7 +63.2 w1,4 (15 +60)x 2 =30 +120 w1,5 (5 +20)x 0 =0 +0 W1 =53.7 +183.2 =0.237 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 3.58 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (+)x 0 x 0 =0 +0 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =0 +0 =0.00 kips 0 3.58 Shear R1=0.424 kips R2=-0.424 kips Stress Ratio Vmax=0.42 kips Vallow.=4.73 x 1 =4.725 kips OK .09 Flexure M=0.380 k-ft Mallow.=6.09 x 1 =6.0908 k-ft OK .06 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.001 +0.000 +0.000 +0.000 =0.00 =L <L OK deflection:.01 32602 240 0.001 +0 D (L Only)=0.001 +0 +0 +0 =0 =L L OK deflection:.01 42159 360 USE:1- 4X12 flexure: 0 0 shear: 2/10/25 12:00 AM B1 0 0 0 80 CASTILLO ENGINEERING, INC.Project 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 Engr.Date:Job No.25-181 Sheet Tag Beam 5 L =3.50 ft Member=4x12 A =39.38 in^2 S =73.8 in^3 No. of members=1 I =415.3 in^4 CD=1.00 E =1,600,000 psi CF=1.10 Va =4.725 kips CV=1.00 Ma =5.537 k-ft Cr=1.00 Total Load L/n=240 Live Load L/n=360 L=3.5 ft 0.37 0.37 Uniform load (W1) D L Trib w1,1 (15 +20)x 0 =0 +0 w1,2 (16 +0)x 0 =0 +0 w1,3 (15 +40)x 1 =15 +40 w1,4 (15 +60)x 2.08 =31.2 +124.8 w1,5 (5 +20)x 0 =0 +0 W1 =46.2 +164.8 =0.211 klf Triangular load (W2) D L Trib ` w2,1 (0 +1.84)x 0 =0 +0 w2,2 (0 +0)x 0 =0 +0 w2,3 (0 +0)x 0 =0 +0 w2,4 (0 +0)x 0 =0 +0 w2,5 (0 +0)x 0 =0 +0 W2 =0 +0 =0.000 klf Point Load (P1) D L Trib.1 Trib.2 TAG: p1,1 (+)x 0.00 x 0.00 =0 +0 0 p1,2 (+)x 0 x 0 =0 +0 0 p1,3 (+)x 0 x 0 =0 +0 0 p1,4 (+)x 0 x 0 =0 +0 p1,5 (+)x 0 x 0 =0 +0 X1 (ft)X2 (ft) P1 =0 +0 =0.00 kips 0 3.5 Point Load (P2) D L Trib.1 Trib.2 TAG: p2,1 (+)x 0 x 0 =0 +0 0 p2,2 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 0 p2,4 (+)x 0 x 0 =0 +0 p2,5 (+)x 0 x 0 =0 +0 X3 (ft)X4 (ft) P2 =0 +0 =0.00 kips 0 3.5 Shear R1=0.369 kips R2=-0.369 kips Stress Ratio Vmax=0.37 kips Vallow.=4.73 x 1 =4.725 kips OK .08 Flexure M=0.323 k-ft Mallow.=6.09 x 1 =6.0908 k-ft OK .05 Deflection D =D w1 +Dw2 +D p1 +Dp2 D (D+L)=0.001 +0.000 +0.000 +0.000 =0.00 =L <L OK deflection:.01 39172 240 0.001 +0 D (L Only)=8E-04 +0 +0 +0 =0 =L L OK deflection:.01 50154 360 USE:1- 4X12 flexure: 0 0 shear: 2/10/25 12:00 AM B2 0 0 0 81 ARCHITECT CASTILLO ENGINEERING JOB 1012 N KEMP STREET 1147 E Market, Long Beach, CA 90805 ENGR. MC DATE JOB NO. 25-181 SHEET NO. CONTINUOUS FOOTINGS CF-1 LOADING:TRIB. ( + ) x ft = + ( + ) x ft = + ( + ) x ft = + DECK ( + ) x ft = + w = + =plf B=plf = ft psf USE: CF-2 LOADING:TRIB. ( + ) x ft = + ( + ) x ft = + ( + ) x ft = + w = + =plf B=plf = ft psf USE: CF-3 LOADING:TRIB. ( + ) x ft = + ( + ) x ft = + ( + ) x ft = + w = + =plf B=plf = ft psf USE: 0 15 16 0 8 0 1'-0" WIDE FTG. 596.25 FLOOR: WALL: 40 1'-0" WIDE FTG. 1.33 19.95 53.2 0 190 40 56.25 0 406.25 596.25 0.40 1500 ROOF: 15 D L 20 ROOF: 1'-0" WIDE FTG.1500 201.15 128 0 201.15 0.13 147.95 53.2 0 320 30 WALL: 16 0 20 FLOOR:40 3.75 150 0.44 D L 215 20 15 1500 665.75 272 225 0 0 168.75 0 225 0 WALL:17 10/02/2025 20 D L ROOF: FLOOR: 15 11.25 0 665.75 16 440.75 4015 0 15 60 0 F-CONTINUOUS FOOTINGS-1500.XLS 82 ARCHITECT Castillo Engineering, Inc.PROJECT 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 ENGR. MC DATE JOB NO. 25-181 SHEET NO. Given: h1 =24 in.d =3.5 in.D L TRIB D L w1 15 20 11 =169 +225 h2 =8 in.W =12 in.15 40 0 =0 +0 16 0 17 =272 +0 H =32 in.12 20 0 =0 +0 441 +225 =666 plf Area = 810 in.2 L = 67.5 in. 5.625 ft.2 = 5.63 ft. Conc. Wt. = 150 x 12 x 8 /144 = 100 plf Abv. Grade =766 qa =1500 psf Pa =1500 x 5.63 =8.44 kips Pload =766 x 5.63 =4.31 kips Pnet = 8.44 - 4.31 = 4.13 kips CF1 FOOTING CAPACITY Pnet = 10/02/2025 4.13 kips wuniform 83 ARCHITECT Castillo Engineering, Inc.PROJECT 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 ENGR. MC DATE JOB NO. 25-181 SHEET NO. Given: h1 =24 in.d =3.5 in.D L TRIB D L w1 15 20 2 =30 +40 h2 =8 in.W =12 in.15 40 3.8 =56 +150 16 0 20 =320 +0 H =32 in.12 20 0 =0 +0 406 +190 =596 plf Area = 810 in.2 L = 67.5 in. 5.625 ft.2 = 5.63 ft. Conc. Wt. = 150 x 12 x 8 /144 = 100 plf Abv. Grade =696 qa =1500 psf Pa =1500 x 5.63 =8.44 kips Pload =696 x 5.63 =3.92 kips Pnet = 8.44 - 3.92 = 4.52 kips CF2 FOOTING CAPACITY Pnet = 10/02/2025 4.52 kips wuniform 84 ARCHITECT Castillo Engineering, Inc.PROJECT 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 ENGR. MC DATE JOB NO. 25-181 SHEET NO. Given: h1 =24 in.d =3.5 in.D L TRIB D L w1 15 20 0 =0 +0 h2 =8 in.W =12 in.15 40 1.3 =20 +53.2 16 0 8 =128 +0 H =32 in.12 20 0 =0 +0 148 +53.2 =201 plf Area = 810 in.2 L = 67.5 in. 5.625 ft.2 = 5.63 ft. Conc. Wt. = 150 x 12 x 8 /144 = 100 plf Abv. Grade =301 qa =1500 psf Pa =1500 x 5.63 =8.44 kips Pload =301 x 5.63 =1.69 kips Pnet = 8.44 - 1.69 = 6.74 kips CF3 FOOTING CAPACITY Pnet = 10/02/2025 6.74 kips wuniform 85 ARCHITECT Castillo Engineering, Inc.PROJECT 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 ENGR. MC DATE JOB NO. 25-181 SHEET NO. Given: h1 =18 in.d =3.5 in.D L TRIB D L w1 15 20 2.3 =34 +45 h2 =8 in.W =12 in.15 40 0 =0 +0 16 0 8 =128 +0 H =26 in.12 20 0 =0 +0 162 +45 =207 plf Area = 666 in.2 L = 55.5 in. 4.625 ft.2 = 4.63 ft. Conc. Wt. = 150 x 12 x 8 /144 = 100 plf Abv. Grade =307 qa =1500 psf Pa =1500 x 4.63 =6.94 kips Pload =307 x 4.63 =1.42 kips Pnet = 6.94 - 1.42 = 5.52 kips (E)CF1 FOOTING CAPACITY Pnet = 10/02/2025 5.52 kips wuniform 86 ARCHITECT Castillo Engineering, Inc.PROJECT 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 ENGR. MC DATE JOB NO. 25-181 SHEET NO. Given: h1 =18 in.d =3.5 in.D L TRIB D L w1 15 20 0 =0 +0 h2 =8 in.W =12 in.15 40 10 =151 +403 16 0 8 =128 +0 H =26 in.12 20 0 =0 +0 279 +403 =682 plf Area = 666 in.2 L = 55.5 in. 4.625 ft.2 = 4.63 ft. Conc. Wt. = 150 x 12 x 8 /144 = 100 plf Abv. Grade =782 qa =1500 psf Pa =1500 x 4.63 =6.94 kips Pload =782 x 4.63 =3.62 kips Pnet = 6.94 - 3.62 = 3.32 kips (E)CF2 FOOTING CAPACITY Pnet = 10/02/2025 3.32 kips wuniform 87 ARCHITECT Castillo Engineering, Inc.PROJECT 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 ENGR. MC DATE JOB NO. 25-181 SHEET NO. Given: h1 =18 in.d =3.5 in.D L TRIB D L w1 15 20 0 =0 +0 h2 =8 in.W =12 in.15 40 3 =45 +120 16 0 8 =128 +0 H =26 in.12 20 0 =0 +0 173 +120 =293 plf Area = 666 in.2 L = 55.5 in. 4.625 ft.2 = 4.63 ft. Conc. Wt. = 150 x 12 x 8 /144 = 100 plf Abv. Grade =393 qa =1500 psf Pa =1500 x 4.63 =6.94 kips Pload =393 x 4.63 =1.82 kips Pnet = 6.94 - 1.82 = 5.12 kips (E)CF3 FOOTING CAPACITY Pnet = 10/02/2025 5.12 kips wuniform 88 ARCHITECT CASTILLO ENGINEERING, INC.JOB 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 ENGR. MC DATE JOB NO. 25-181 SHEET NO. SPREAD FOOTINGS P1 =K P2 =K P3 =K P4 =K TOTAL =K P ALLOW.=K USE:TYPE 2.0 FOOTING P1 =K P2 =K P3 =K P4 =K TOTAL =K P ALLOW.=K USE:TYPE 2.5 FOOTING P1 = K P2 = K P3 = K P4 = K = K = K USE:TYPE 2.5 FOOTING P1 =K P2 =K P3 =K P4 =K P TOTAL =K P ALLOW.=K USE:TYPE 2.0 FOOTING P1 =K P2 =K P3 =K P4 =K P TOTAL =K P ALLOW.=K USE:TYPE 2.0 FOOTING 6.23 8.44 F3 0 8.44 0 0 3.25 0 7.28 5.4 2.98 0.81 0 0 3.79 F5 0 0 F4 0.37 0.37 5.4 0 F1 0.02 0 0 F2 2.98 10/02/2025 0 0 0.02 5.4 7.28 F-SPREAD FOOTINGS1500.xls 89 ARCHITECT CASTILLO ENGINEERING, INC.JOB 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 ENGR. MC DATE JOB NO. 25-181 SHEET NO. SPREAD FOOTINGS P1 =K P2 =K P3 =K P4 =K TOTAL =K P ALLOW.=K USE:TYPE 2.0 FOOTING P1 =K P2 =K P3 =K P4 =K TOTAL =K P ALLOW.=K USE:TYPE 2.0 FOOTING P1 = K P2 = K P3 = K P4 = K = K = K USE:TYPE 2.0 FOOTING P1 =K P2 =K P3 =K P4 =K P TOTAL =K P ALLOW.=K USE:TYPE 2.0 FOOTING P1 =K P2 =K P3 =K P4 =K P TOTAL =K P ALLOW.=K USE:TYPE 2.0 FOOTING 12/02/2025 0 0.22 2.56 5.4 0.42 F6 0.42 0.37 1.55 F7 0.81 F10 0 0 F9 5.24 5.24 5.4 0 5.4 1.98 0 0 0 1.98 1.46 5.4 F8 0 5.4 0 0 0.65 0 0.42 F-SPREAD FOOTINGS1500.xls 90 ARCHITECT CASTILLO ENGINEERING, INC.JOB 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 ENGR. MC DATE JOB NO. 25-181 SHEET NO. SPREAD FOOTINGS P1 =K P2 =K P3 =K P4 =K TOTAL =K P ALLOW.=K USE:TYPE 2.5 FOOTING P1 =K P2 =K P3 =K P4 =K TOTAL =K P ALLOW.=K USE:TYPE 2.0 FOOTING P1 = K P2 = K P3 = K P4 = K = K = K USE:TYPE 2.0 FOOTING P1 =K P2 =K P3 =K P4 =K P TOTAL =K P ALLOW.=K USE:TYPE 2.0 FOOTING P1 =K P2 =K P3 =K P4 =K P TOTAL =K P ALLOW.=K USE:TYPE 3.5 FOOTING 0.42 5.4 F13 0 5.4 0 0 0 0 0.6 16.5 13.19 0 0 0 13.19 F15 0 0 F14 1.92 1.92 5.4 0 F11 7.51 0 0 F12 0.42 10/02/2025 0 0 7.51 8.44 0.6 F-SPREAD FOOTINGS1500.xls 91 ARCHITECT CASTILLO ENGINEERING, INC.JOB 1012 N KEMP STREET 1147 E Market Street Long Beach, CA 90805 ENGR. MC DATE JOB NO. 25-181 SHEET NO. SPREAD FOOTINGS P1 =K P2 =K P3 =K P4 =K TOTAL =K P ALLOW.=K USE:TYPE 2.5 FOOTING P1 =K P2 =K P3 =K P4 =K TOTAL =K P ALLOW.=K USE:TYPE 2.5 FOOTING 1.24 8.44 0 6.48 F16 4.76 1.4 0 F17 10/02/2025 0 0 6.16 8.44 5.24 F-SPREAD FOOTINGS1500.xls 92 ARCHITECT CASTILLO ENGINEERING JOB 1205 Pine Avenue, Suite 201, Long Beach, CA 90813 ENGR. MC JOB NO. SHEET NO. C1 Flagpole Footing - Nonconstrained CBC07, Section 1805.7.2.1 F=lbs applied lateral force h=ft distance from ground to point of application of F Pp =pcf passive bearing pressure Table 1804.2 Note: 2x Increase allowed for minor structures 1804.3.1 1.33 Increase allowed for wind or seismic, footnote d Footing Dimension B=ft b=ft diameter or diagonal dimension of square footing d=ft depth of embedment OK S1=psf A =` req.=ft USE:3.25 FT x 4.00 FT DEEP FLAGPOLE FOOTING ( 4.60 FT. DIA. OPTIONAL) 804 8.5 266.67 4.60 4.00 3.25 356 3.89 1.15 =2.34 · F S1 · b [Eqn. 1] = (A / 2) · (1 + [1 + 4.36 · h / A]0.5) [Eqn. 2] 93 PROJECT : PAGE : CLIENT : DESIGN BY : JOB NO. : DATE : 02/10/25 REVIEW BY : INPUT DATA Exposure category (B, C or D)B Importance factor I = 1.00 Category II Basic wind speed V = 110 mph Topographic factor Kzt =1 Flat Building height to eave he =17 ft Building height to ridge hr =20 ft Building length L =28 ft Building width B =31 ft Effective area of components A =96.33333 2 DESIGN SUMMARY Max horizontal force normal to building length, L, face =7.28 kips X 0.6= 4.37 Max horizontal force normal to building length, B, face =8.00 kips X 0.6= 4.80 Max total horizontal torsional load = 31.19 ft-kips Max total upward force = 12.70 kips ANALYSIS Velocity pressure qh = 0.00256 Kh Kzt Kd V2 I =18.43 psf where: qh = velocity pressure at mean roof height, h. Kh = velocity pressure exposure coefficient evaluated at height, h,= 0.70 Kd = wind directionality factor = 0.85 h = mean roof height = 18.50 ft < 60 ft, [Satisfactory] Design pressures for MWFRS p = qh [(G Cpf )-(G Cpi )] where: p = pressure in appropriate zone G Cp f = product of gust effect factor and external pressure coefficient G Cp i = product of gust effect factor and internal pressure coefficient = 0.18 or -0.18 a = width of edge strips, MAX[ MIN(0.1B, 0.4h), 0.04B,3] =3.10 ft Net Pressures (psf), Basic Load Cases Net Pressures (psf), Torsional Load Cases 10.95 0.00 10.95 (+GCp i ) (-GCp i )(+GCp i ) (-GCp i )(+GCp i ) (-GCp i ) 1 0.45 5.01 11.64 0.40 4.05 10.69 1T 0.45 1.25 2.91 2 -0.69 -16.03 -9.40 -0.69 -16.03 -9.40 2T -0.69 -4.01 -2.35 3 -0.41 -10.94 -4.31 -0.37 -10.14 -3.50 3T -0.41 -2.74 -1.08 4 -0.35 -9.69 -3.05 -0.29 -8.66 -2.03 4T -0.35 -2.42 -0.76 1E 0.69 9.32 15.95 0.61 7.93 14.56 3E -0.59 -14.26 -7.62 -0.53 -13.09 -6.45 (+GCp i ) (-GCp i ) 4E -0.51 -12.78 -6.14 -0.43 -11.24 -4.61 1T 0.40 1.01 2.67 5 -0.45 -11.61 -4.98 -0.45 -11.61 -4.98 2T -0.69 -4.01 -2.35 6 -0.45 -11.61 -4.98 -0.45 -11.61 -4.98 3T -0.37 -2.53 -0.88 4T -0.29 -2.17 -0.51 CASTILLO Net Pressure withG Cp f Wind Analysis for Low-rise Building, Based on ASCE 7-22 / IBC 2024 / CBC 2022 Roof angle q = G Cp f Net Pressure with 25-181 1012 N KEMO STREET Surface Roof angle q = G Cp f Net Pressure with Surface Roof angle q = G Cp f ENGINEERING Surface Roof angle q = Net Pressure with 94 Basic Load Cases in Transverse Direction Basic Load Cases in Longitudinal Direction Area Area (ft2)(+GCp i ) (-GCp i )(ft2)(+GCp i ) (-GCp i ) 1 371 1.86 4.31 1 464 1.88 4.96 2 344 -5.52 -3.24 2 354 -5.67 -3.32 3 344 -3.77 -1.48 3 354 -3.58 -1.24 4 371 -3.59 -1.13 4 464 -4.02 -0.94 1E 105 0.98 1.68 1E 109 0.86 1.59 2E 98 -2.26 -1.61 2E 88 -2.04 -1.45 3E 98 -1.40 -0.75 3E 88 -1.16 -0.57 4E 105 -1.35 -0.65 4E 109 -1.23 -0.50 Horiz. 7.28 7.28 Horiz. 8.00 8.00 Vert. -12.70 -6.94 Vert. -12.22 -6.46 10 psf min.Horiz. 5.60 5.60 10 psf min.Horiz. 5.74 5.74 Sec. 6.1.4.1 Vert. -8.68 -8.68 Sec. 6.1.4.1 Vert. -8.68 -8.68 Torsional Load Cases in Transverse Direction Torsional Load Cases in Longitudinal Direction Area Area (ft2)(+GCp i ) (-GCp i ) (+GCp i ) (-GCp i )(ft2)(+GCp i ) (-GCp i ) (+GCp i ) (-GCp i ) 1 133 0.66 1.54 4 8 1 178 0.72 1.90 3 9 2 123 -1.97 -1.16 -2 -1 2 265 -4.25 -2.49 6 3 3 123 -1.35 -0.53 1 1 3 265 -2.69 -0.93 -4 -1 4 133 -1.28 -0.40 7 2 4 178 -1.54 -0.36 7 2 1E 105 0.98 1.68 11 18 1E 109 0.86 1.59 11 20 2E 98 -2.26 -1.61 -5 -3 2E 88 -2.04 -1.45 3 2 3E 98 -1.40 -0.75 3 2 3E 88 -1.16 -0.57 -2 -1 4E 105 -1.35 -0.65 15 7 4E 109 -1.23 -0.50 15 6 1T 238 0.30 0.69 -2 -5 1T 287 0.29 0.77 -2 -6 2T 221 -0.89 -0.52 1 1 2T 354 -1.42 -0.83 -4 -2 3T 221 -0.60 -0.24 -1 0 3T 354 -0.90 -0.31 2 1 4T 238 -0.58 -0.18 -4 -1 4T 287 -0.62 -0.15 -5 -1 28 28 31.2 31.2 Design pressures for components and cladding p = qh[ (G Cp) - (G Cpi)] where: p = pressure on component pmin = 10 psf (Sec. 6.1.4.2, pg 21) G Cp = external pressure coefficient. see table below Effective Area (ft2)P P P P P P P P P P Comp.96.33333 0.30 -0.80 0.30 -1.21 0.30 -2.01 0.83 -0.93 0.83 -1.05 Positive Negative Positive Negative Positive Negative Positive Negative Positive Negative 10.00 -18.09 10.00 -25.58 10.00 -40.36 18.55 -20.39 18.55 -22.72 Pressure Zone 1 Zone 2 Total Horiz. Torsional Load, MT Comp. & Cladding Surface Pressure (k) with Zone 1 ( psf ) Zone 3 Zone 4Zone 2 Zone 5 Zone 3 Zone 4 Zone 5 Pressure (k) with Torsion (ft-k) Total Horiz. Torsional Load, MT Torsion (ft-k)Surface Surface S Surface Pressure (k) withPressure (k) with S 95 ASCE Hazards Report Address: 1012 N Kemp St Anaheim, California 92801 Standard:ASCE/SEI 7-22 Latitude:33.847709 Risk Category:II Longitude:-117.916427 Soil Class:Default Elevation:160.87233439988304 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph 300-year MRI 89 Vmph 700-year MRI 95 Vmph 1,700-year MRI 101 Vmph 3,000-year MRI 106 Vmph 10,000-year MRI 115 Vmph 100,000-year MRI 132 Vmph 1,000,000-year MRI 151 Vmph Data Source: ASCE/SEI 7-22, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Mon Feb 10 2025 Page 1 of 5https://ascehazardtool.org/Mon Feb 10 2025 96 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-22 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Values for 10-year MRI, 25-year MRI, 50-year MRI and 100-year MRI are Service Level wind speeds, all other wind speeds are Ultimate wind speeds. Site is not in a hurricane-prone region as defined in ASCE/SEI 7-22 Section 26.2. Page 2 of 5https://ascehazardtool.org/Mon Feb 10 2025 97 PGA M : 0.76 SMS : 1.93 SM1 : 1.42 SDS : 1.29 SD1 : 0.94 T L : 8 SS : 1.75 S1 : 0.68 VS30 : 260 Seismic Design Category: D Multi-Period Design Spectrum S (g) vs T(s)a Multi-Period MCE SpectrumR S (g) vs T(s)a Two-Period Design Spectrum S (g) vs T(s)a Two-Period MCE SpectrumR S (g) vs T(s)a Design Vertical Response Spectrum Vertical ground motion data has not yet been made available by USGS. MCE Vertical Response SpectrumR Vertical ground motion data has not yet been made available by USGS. Seismic DefaultSite Soil Class: Results: Page 3 of 5https://ascehazardtool.org/Mon Feb 10 2025 98 Data Accessed: Mon Feb 10 2025 Date Source: USGS Seismic Design Maps based on ASCE/SEI 7-22 and ASCE/SEI 7-22 Table 1.5-2. Additional data for site-specific ground motion procedures in accordance with ASCE/SEI 7-22 Ch. 21 are available from USGS. Page 4 of 5https://ascehazardtool.org/Mon Feb 10 2025 99 Snow Results: Ground Snow Load, p : 3 lb/ftg 2 20-year MRI Value: 1 lb/ft^2 Winter Wind Parameter: 0.25 Mapped Elevation: 160.3 ft Data Source: ASCE/SEI 7-22, Figures 7.6-1 and 7.6-2 A-D Date Accessed: Mon Feb 10 2025 Values provided are ground snow loads. In areas designated "case study required," extreme local variations in ground snow loads preclude mapping at this scale. Site-specific case studies are required to establish ground snow loads at elevations not covered. Snow load values are mapped to a 0.5 mile resolution. This resolution can create a mismatch between the mapped elevation and the site-specific elevation in topographically complex areas. Engineers should consult the local authority having jurisdiction in locations where the reported ‘elevation’ and ‘mapped elevation’ differ significantly from each other. Ground Snow Loads for IRC only, p :g(asd)2.1 lb/ft 2 The ASCE Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE Hazard Tool. Page 5 of 5https://ascehazardtool.org/Mon Feb 10 2025 100 SEISMIC BASE SHEAR (ASCE7-22) Latitude: 33.847709 Longitude: -118.91643 SITE CLASS:D (Table 20.3-1)ρ=1.3 R=6.5 (Table 12.2-1)Ie=1 (Section 21.4) 1.930 0 1.420 0 (11.4-3) 1.287 (11.4-4) 0.9466667 0.14715 0.73575 See on Figs. 22-14 through 22-17 0.02 20.000 0.75 0.189 W= Effective seismeic weight (GOVERNS) For S1 is equal to greater than 0.6g 0.109 W 0.770 W 0.198 0.257 W Strength Level 0.180 W Allowable Stress Design 𝑆= 𝑆= 𝑆=3 𝑆 = 𝑆=3 𝑆 = 𝑇= 𝐶ℎ= ℎ= 𝑥= = = =. = =ρW = = == == 101 SEISMIC ANALYSIS WEIGHT Level 2 W roof = 20 psf x 823 ft^2 =16.45 kips W wall = 16 psf x 473 ft^2 =7.56 kips WR =24.01 kips Level 1 W floor= 25 psf x 800 ft^2 = 20.01 kips 16 psf x 473 ft^2 = 7.56 kips 16 psf x 391 ft^2 = 6.26 kips W1 =33.83 kips BASE SHEAR 0.180 x 57.85 kips = 10.42 kips DISTRIBUTION OF BASE SHEAR 1 Level F2=6.11 kips 7.43 psf F1=4.31 kips 5.38 psf 2 or more levels W TOTAL 57.85 kips 𝑽𝑩𝑨𝑺𝑬= 𝑽 ∗ 𝑾𝑻𝑶𝑻𝑨𝑳 = 𝑉 ∗ 𝑊= 𝑭𝒙= 𝑽𝑩𝑨𝑺𝑬∗𝑾𝑿∗ 𝒉𝑻𝑶𝑻𝑨𝑳 𝑾𝟏∗ 𝒉𝟏+𝑾𝟐∗𝒉𝟏+ 𝒉𝟐+ ⋯𝑾𝒏∗ 𝒉𝑻𝑶𝑻𝑨𝑳 𝑩𝑨𝑺𝑬=∗𝑻𝑶𝑻𝑨𝑳 𝑨 102 ARCHITECT JOB ESTRUCTURA USA, INC. 1205 PINE AVE ENGR. MC DATE:LONG BEACH CA JOB NO. 25-181 SHEET NO. First Floor Shearwall Forces L1 Level 1 F1= 5.380 psf DIAPHRAGM X4 5.38 295.00 1.59 KIPS 12.00 ft X5 5.38 87.94 0.47 KIPS 8.16 ft X6 5.38 419.18 2.26 KIPS 4.25 ft Y4 5.38 234.89 1.26 KIPS 12.00 ft Y5 5.38 389.58 2.10 KIPS 11.83 ft Y6 5.38 175.89 0.95 KIPS 15.41 ft C1 5.38 x (6.5/2.5)115.00 1.61 KIPS C1 Second Floor Shearwall Forces L2 Level 2 F2= 7.430 psf SW U-FORCE T.A.FORCE L1 L2 L3 L4 X1 7.43 359.46 2.67 KIPS 13.16 ft 6.75 ft X2 7.43 372.60 2.77 KIPS 5.16 ft X3 7.43 90.45 0.67 KIPS 3.91 ft 4.00 ft Y1 7.43 337.96 2.51 KIPS 13.25 ft Y2 7.43 85.18 0.63 KIPS 3.08 ft 3.91 ft Y3 7.43 399.37 2.97 KIPS 10.41 ft 11.33 ft February 10, 2025 LENGHT WALLS LENGHT WALLS SEISMIC FORCES 1012 N KEMP STREET 103 SHEARWALL 2ND LEVEL KEYPLAN AREA:822.53 SQ. FT. PERIMETER:118.16 FT. X:28.08 FT. Y:31.00 FT. 2.51 K 2.67 K 2.77 K 0.63 K 2.97 K 0.67 K X1.1 X1.2 X2.1 X3.1 X3.2 Y1.1 Y2.1 Y2.2 Y3.1 Y3.2 104 X1.1 X1.2 X2.1 X3.1 X3.2 X DIRECTION 2ND LEVEL KEYPLAN AREA:359.46 SQ. FT. AREA:372.60 SQ. FT. AREA:90.45 SQ. FT. 105 ARCHITECT JOB ESTRUCTURA USA, INC. 1205 Pine Avenue, Suite 201 ENGR. MC Long Beach, CA 90813 25-181 SHEET NO. TAG:X1.1 ( 13.16 ft),X1.2 ( 6.75 ft) FORCE: SEISMIC GOVERNS F2=kips Load Comb.:(0.6-.14SDS)D + 0.7 E SDS= 1.29 SHEAR STRESS X1.1 : L1=ft v=lbs =plf X1.2 : L2=ft ft Ltotal=ft OVERTURNING height= 8.00 ft MOT=x x 8 = ROOF:psf x ft =plf h/w= 0.61 OK WALL:psf x ft =plf w =plf Vallow=340 PLF MR=x 13.16 ^2/2 =k-ft USE: TYPE 6 SHEARWALL - 0.42 x =kips kips OK USE:4 x 4 POST w/H.D. height= 8.00 ft MOT=x x 8 = ROOF:psf x ft =plf h/w= 1.19 OK WALL:psf x ft =plf w =plf Vallow=340 PLF MR=x 6.75 ^2/2 =k-ft USE: TYPE 6 SHEARWALL - 0.42 x =kips kips OK USE:4 x 4 POST w/H.D. 6.75 19.91 1012 N KEMP STREET SHEARWALL CALCULATIONS-LEVEL 2 2.67 13.16 2671 134 15 11 169 19.91 Unit load Tributary 19.91 13.16 14.12 WALL:X1.1 2.67 T= 14.12 25.70 0.25 128 297 0.297 25.70 16 8 ST-1 WALL:X1.2 13.16 Tallow=1.03 16 8 128 15 11 169 19.91 Unit load Tributary 7.24 2.67 6.75 ST-1 T= 7.24 6.76 0.65 6.75 Tallow=1.03 0.297 6.76 297 106 ARCHITECT JOB ESTRUCTURA USA, INC. 1205 Pine Avenue, Suite 201 ENGR. MC Long Beach, CA 90813 25-181 SHEET NO. TAG:X2.1 ( 5.16 ft), FORCE: SEISMIC GOVERNS F2=kips Load Comb.:(0.6-.14SDS)D + 0.7 E SDS= 1.29 SHEAR STRESS X2.1 : L1=ft v=lbs =plf ft Ltotal=ft OVERTURNING height= 8.00 ft MOT=x x 8 = ROOF:psf x ft =plf h/w= 1.55 OK WALL:psf x ft =plf w =plf Vallow=665 PLF MR=x 5.16 ^2/2 =k-ft USE: TYPE 3 SHEARWALL - 0.42 x =kips kips OK USE:4 x 4 POST w/H.D. 5.16 1012 N KEMP STREET SHEARWALL CALCULATIONS-LEVEL 2 2.77 5.16 2768 537 15 11 169 5.16 Unit load Tributary 5.16 5.16 22.15 WALL:X2.1 2.77 T= 22.15 3.95 3.97 128 297 0.297 3.95 16 8 ST-6 5.16 Tallow=4.87 107 ARCHITECT JOB ESTRUCTURA USA, INC. 1205 Pine Avenue, Suite 201 ENGR. MC Long Beach, CA 90813 25-181 SHEET NO. TAG:X3.1 ( 3.91 ft),X3.2 ( 4.00 ft) FORCE: SEISMIC GOVERNS F2=kips Load Comb.:(0.6-.14SDS)D + 0.7 E SDS= 1.29 SHEAR STRESS X3.1 : L1=ft v=lbs =plf X3.2 : L2=ft ft Ltotal=ft OVERTURNING height= 8.00 ft MOT=x x 8 = ROOF:psf x ft =plf h/w= 2.05 2w/h factor= 0.99 WALL:psf x ft =plf w =plf Vallow=340 x 0.99 =PLF MR=x 3.91 ^2/2 =k-ft USE: TYPE 6 SHEARWALL - 0.42 x =kips kips OK USE:4 x 4 POST w/H.D. height= 8.00 ft MOT=x x 8 = ROOF:psf x ft =plf h/w= 2.00 OK WALL:psf x ft =plf w =plf Vallow=340 PLF MR=x 4.00 ^2/2 =k-ft USE: TYPE 6 SHEARWALL - 0.42 x =kips kips OK USE:4 x 4 POST w/H.D. 4.00 7.91 1012 N KEMP STREET SHEARWALL CALCULATIONS-LEVEL 2 0.67 3.91 672 85 338 15 2 30 7.91 Unit load Tributary 7.91 3.91 2.66 WALL:X3.1 0.67 T= 2.66 1.33 0.54 144 174 0.174 1.33 16 9 ST-1 WALL:X3.2 3.91 Tallow=1.03 16 9 144 15 2 30 7.91 Unit load Tributary 2.72 0.67 4.00 ST-1 T= 2.72 1.39 0.53 4.00 Tallow=1.03 0.174 1.39 174 108 Y1.1 Y2.1 Y2.2 Y3.1 Y3.2 Y DIRECTION 2ND LEVEL KEYPLAN AREA:337.96 SQ. FT.AREA:399.37 SQ. FT. AREA:85.18 SQ. FT. 109 ARCHITECT JOB ESTRUCTURA USA, INC. 1205 Pine Avenue, Suite 201 ENGR. MC Long Beach, CA 90813 25-181 SHEET NO. TAG:Y1.1 ( 13.25 ft), FORCE: SEISMIC GOVERNS F2=kips Load Comb.:(0.6-.14SDS)D + 0.7 E SDS= 1.29 SHEAR STRESS Y1.1 : L1=ft v=lbs =plf ft Ltotal=ft OVERTURNING height= 8.00 ft MOT=x x 8 = ROOF:psf x ft =plf h/w= 0.60 OK WALL:psf x ft =plf w =plf Vallow=340 PLF MR=x 13.25 ^2/2 =k-ft USE: TYPE 6 SHEARWALL - 0.42 x =kips kips OK USE:4 x 4 POST w/H.D. 13.25 1012 N KEMP STREET SHEARWALL CALCULATIONS-LEVEL 2 2.51 13.25 2511 190 15 2 30 13.25 Unit load Tributary 13.25 13.25 20.09 WALL:Y1.1 2.51 T= 20.09 15.27 1.03 144 174 0.174 15.27 16 9 ST-2 13.25 Tallow=1.28 110 ARCHITECT JOB ESTRUCTURA USA, INC. 1205 Pine Avenue, Suite 201 ENGR. MC Long Beach, CA 90813 25-181 SHEET NO. TAG:Y2.1 ( 3.08 ft),Y2.2 ( 3.91 ft) FORCE: SEISMIC GOVERNS F2=kips Load Comb.:(0.6-.14SDS)D + 0.7 E SDS= 1.29 SHEAR STRESS Y2.1 : L1=ft v=lbs =plf Y2.2 : L2=ft ft Ltotal=ft OVERTURNING height= 8.00 ft MOT=x x 8 = ROOF:psf x ft =plf h/w= 2.60 2w/h factor= 0.93 WALL:psf x ft =plf w =plf Vallow=340 x 0.93 =PLF MR=x 3.08 ^2/2 =k-ft USE: TYPE 6 SHEARWALL - 0.42 x =kips kips OK USE:4 x 4 POST w/H.D. height= 8.00 ft MOT=x x 8 = ROOF:psf x ft =plf h/w= 2.05 2w/h factor= 0.99 WALL:psf x ft =plf w =plf Vallow=340 x 0.99 = MR=x 3.91 ^2/2 =k-ft USE: TYPE 6 SHEARWALL - 0.42 x =kips kips OK USE:4 x 4 POST w/H.D. 3.91 6.99 1012 N KEMP STREET SHEARWALL CALCULATIONS-LEVEL 2 0.63 3.08 633 91 315 15 7 105 6.99 Unit load Tributary 6.99 3.08 2.23 WALL:Y2.1 0.63 T= 2.23 1.11 0.57 128 233 0.233 1.11 16 8 ST-1 WALL:Y2.2 3.08 Tallow=1.03 16 8 128 15 7 105 6.99 Unit load Tributary 2.83 0.63 3.91 338 ST-1 T= 2.83 1.78 0.53 3.91 Tallow=1.03 0.233 1.78 233 111 ARCHITECT JOB ESTRUCTURA USA, INC. 1205 Pine Avenue, Suite 201 ENGR. MC Long Beach, CA 90813 25-181 SHEET NO. TAG:Y3.1 ( 10.41 ft),Y3.2 ( 11.33 ft) FORCE: SEISMIC GOVERNS F2=kips Load Comb.:(0.6-.14SDS)D + 0.7 E SDS= 1.29 SHEAR STRESS Y3.1 : L1=ft v=lbs =plf Y3.2 : L2=ft ft Ltotal=ft OVERTURNING height= 8.00 ft MOT=x x 8 = ROOF:psf x ft =plf h/w= 0.77 OK WALL:psf x ft =plf w =plf Vallow=340 PLF MR=x 10.41 ^2/2 =k-ft USE: TYPE 6 SHEARWALL - 0.42 x =kips kips OK USE:4 x 4 POST w/H.D. height= 8.00 ft MOT=x x 8 = ROOF:psf x ft =plf h/w= 0.71 OK WALL:psf x ft =plf w =plf Vallow=340 PLF MR=x 11.33 ^2/2 =k-ft USE: TYPE 6 SHEARWALL - 0.42 x =kips kips OK USE:4 x 4 POST w/H.D. 11.33 21.74 1012 N KEMP STREET SHEARWALL CALCULATIONS-LEVEL 2 2.97 10.41 2967 136 15 2 30 21.74 Unit load Tributary 21.74 10.41 11.37 WALL:Y3.1 2.97 T= 11.37 8.56 0.75 128 158 0.158 8.56 16 8 ST-1 WALL:Y3.2 10.41 Tallow=1.03 16 8 128 15 2 30 21.74 Unit load Tributary 12.37 2.97 11.33 ST-1 T= 12.37 10.14 0.72 11.33 Tallow=1.03 0.158 10.14 158 112 X4.1 X5.1 X6.1 Y4.1 Y5.1 Y6.1 1.26 K 1.13 K 0.95 K 2.26 K 2.10 K C1 C1 AREA:800.46 SQ. FT. PERIMETER:97.83 FT. X:31.08 FT. Y:18.91 FT. SHEARWALL 1ST LEVEL KEYPLAN 0.47 K 113 X4.1 X5.1 X6.1 C1 C1 X DIRECTION 1ST LEVEL KEYPLAN AREA:209.23 SQ. FT. AREA:87.94 SQ. FT. AREA:419.18 SQ. FT. AREA:84.09 SQ. FT. 114 ARCHITECT JOB ESTRUCTURA USA, INC. 1205 Pine Avenue, Suite 201 ENGR. MC Long Beach, CA 90813 JOB NO. SHEET NO. TAG:X4.1 ( 12.00 ft) FORCE: h2=8.00 ft F1=kips h1=8.00 ft SEISMIC GOVERNS FTOTAL=kips Load Comb.:(0.6-.14SDS) D + 0.7 E SDS= 1.45 SHEAR STRESS X4.1 : L1=ft v=lbs =plf ft Ltotal=ft OVERTURNING MOT=x 12.00 x 16.0 + 3.80 x 12.00 x 8.00 =k-ft 12.00 12.00 ROOF:psf x ft =plf FLOOR:psf x ft =plf h/w=0.67 OK WALL:psf x ft =plf w =plf Vallow=340 PLF MR=x 12.00 ^2/2 =k-ft USE: TYPE 6 SHEARWALL - 0.42 x =kips kips OK USE:4 x 4 POST w/H.D. SHEARWALL CALCULATIONS-LEVEL 1 3.80 3.80 12.00 3800 317 30.40 12.00 12.00 30 15 0 0 WALL:X4.1 0.00 Unit load Tributary 15 2 16 8 128 158 T= 30.4 11.38 2.14 0.158 11.38 12.00 HDU2Tallow=3.08 115 ARCHITECT JOB 754 ET ESTRUCTURA USA, INC. 1205 Pine Avenue, Suite 201 ENGR. MC Long Beach, CA 90813 21-107 SHEET NO. TAG:X5.1 ( 8.16 ft) FORCE: F2=kips h2=8.00 ft F1=kips h1=8.00 ft SEISMIC GOVERNS FTOTAL=kips Load Comb.:(0.6-.14SDS) D + 0.7 E SDS= 1.45 SHEAR STRESS X5.1 : L1=ft v=lbs =plf ft Ltotal=ft OVERTURNING MOT=x 8.16 x 16.0 + 0.47 x 8.16 x 8.00 =k-ft 8.16 8.16 ROOF:psf x ft =plf FLOOR:psf x ft =plf h/w=0.98 OK WALL:psf x ft =plf w =plf Vallow=510 PLF MR=x 8.16 ^2/2 =k-ft USE: TYPE 4 SHEARWALL - 0.42 x =kips kips OK USE:4 x 4 POST w/H.D. 8.16 HDU8Tallow=5.23 T= 46.5 14.67 4.95 0.441 14.67 16 17 272 441 169 15 0 0 WALL:X5.1 2.67 Unit load Tributary 15 11 46.52 8.16 8.16 SHEARWALL CALCULATIONS-LEVEL 1 2.67 0.47 3.14 8.16 3144 385 116 ARCHITECT JOB ESTRUCTURA USA, INC. 1205 Pine Avenue, Suite 201 ENGR. MC Long Beach, CA 90813 JOB NO. SHEET NO. TAG:X6.1 ( 4.25 ft) FORCE: h2=8.00 ft F1=kips h1=8.00 ft SEISMIC GOVERNS FTOTAL=kips Load Comb.:(0.6-.14SDS) D + 0.7 E SDS= 1.45 SHEAR STRESS X6.1 : L1=ft v=lbs =plf ft Ltotal=ft OVERTURNING MOT=x 4.25 x 16.0 + 5.03 x 4.25 x 8.00 =k-ft 4.25 4.25 ROOF:psf x ft =plf FLOOR:psf x ft =plf h/w=1.88 OK WALL:psf x ft =plf w =plf Vallow=1330 PLF MR=x 4.25 ^2/2 =k-ft USE: TYPE 3D SHEARWALL - 0.42 x =kips kips OK USE:4 x 4 POST w/H.D. 4.25 HDU14Tallow=10.83 T= 40.2 1.43 9.33 0.158 1.43 16 8 128 158 0 15 2 30 WALL:X6.1 0.00 Unit load Tributary 15 0 40.24 4.25 4.25 SHEARWALL CALCULATIONS-LEVEL 1 5.03 5.03 4.25 5030 1184 117 Y4.1 Y5.1 Y6.1 Y DIRECTION 1ST LEVEL KEYPLAN AREA:389.58 SQ. FT. AREA:175.89 SQ. FT. AREA:234.98 SQ. FT. 118 ARCHITECT JOB 754 ET ESTRUCTURA USA, INC. 1205 Pine Avenue, Suite 201 ENGR. MC Long Beach, CA 90813 21-107 SHEET NO. TAG:Y4.1 ( 12.00 ft) FORCE: h2=8.00 ft F1=kips h1=8.00 ft SEISMIC GOVERNS FTOTAL=kips Load Comb.:(0.6-.14SDS) D + 0.7 E SDS= 1.45 SHEAR STRESS Y4.1 : L1=ft v=lbs =plf ft Ltotal=ft OVERTURNING MOT=x 12.00 x 16.0 + 3.77 x 12.00 x 8.00 =k-ft 12.00 12.00 ROOF:psf x ft =plf FLOOR:psf x ft =plf h/w=0.67 OK WALL:psf x ft =plf w =plf Vallow=340 PLF MR=x 12.00 ^2/2 =k-ft USE: TYPE 6 SHEARWALL - 0.42 x =kips kips OK USE:4 x 4 POST w/H.D. 12.00 HDU2Tallow=2.31 T= 30.2 11.38 2.12 0.158 11.38 16 8 128 158 30 15 0 0 WALL:Y4.1 0.00 Unit load Tributary 15 2 30.16 12.00 12.00 SHEARWALL CALCULATIONS-LEVEL 1 3.77 3.77 12.00 3770 314 119 ARCHITECT JOB 754 ET ESTRUCTURA USA, INC. 1205 Pine Avenue, Suite 201 ENGR. MC Long Beach, CA 90813 21-107 SHEET NO. TAG:Y5.1 ( 11.83 ft) FORCE: F2=kips h2=8.00 ft F1=kips h1=8.00 ft SEISMIC GOVERNS FTOTAL=kips Load Comb.:(0.6-.14SDS) D + 0.7 E SDS= 1.45 SHEAR STRESS Y5.1 : L1=ft v=lbs =plf ft Ltotal=ft OVERTURNING MOT=x 11.83 x 16.0 + 2.10 x 11.83 x 8.00 =k-ft 11.83 11.83 ROOF:psf x ft =plf FLOOR:psf x ft =plf h/w=0.68 OK WALL:psf x ft =plf w =plf Vallow=340 PLF MR=x 11.83 ^2/2 =k-ft USE: TYPE 6 SHEARWALL - 0.42 x =kips kips OK USE:4 x 4 POST w/H.D. 11.83 HDU2Tallow=2.31 T= 26.9 11.06 1.88 0.158 11.06 16 8 128 158 30 15 0 0 WALL:Y5.1 0.63 Unit load Tributary 15 2 26.89 11.83 11.83 SHEARWALL CALCULATIONS-LEVEL 1 0.63 2.10 2.73 11.83 2729 231 120 ARCHITECT JOB ESTRUCTURA USA, INC. 1205 Pine Avenue, Suite 201 ENGR. MC Long Beach, CA 90813 JOB NO. SHEET NO. TAG:Y6.1 ( 15.41 ft) FORCE: F2=kips h2=8.00 ft F1=kips h1=8.00 ft SEISMIC GOVERNS FTOTAL=kips Load Comb.:(0.6-.14SDS) D + 0.7 E SDS= 1.45 SHEAR STRESS Y6.1 : L1=ft v=lbs =plf ft Ltotal=ft OVERTURNING MOT=x 15.41 x 16.0 + 0.95 x 15.41 x 8.00 =k-ft 15.41 15.41 ROOF:psf x ft =plf FLOOR:psf x ft =plf h/w=0.52 OK WALL:psf x ft =plf w =plf Vallow=340 PLF MR=x 15.41 ^2/2 =k-ft USE: TYPE 6 SHEARWALL - 0.42 x =kips kips OK USE:4 x 4 POST w/H.D. 15.41 HDU2Tallow=2.31 T= 55.0 46.78 2.30 0.394 46.78 16 19 304 394 30 15 4 60 WALL:Y6.1 2.97 Unit load Tributary 15 2 55.05 15.41 15.41 SHEARWALL CALCULATIONS-LEVEL 1 2.97 0.95 3.91 15.41 3914 254 121 Steel Column LIC# : KW-06017148, Build:20.24.10.30 CASTILLO ENGINEERING INC.(c) ENERCALC, LLC 1982-2025 DESCRIPTION:C1* Project File: 25-132.ec6 Project Title: Engineer: .Code References Calculations per AISC 360-16, IBC 2018, CBC 2019 Load Combinations Used : ASCE 7-22 / IBC 2024 (L<=100psf) General Information Steel Stress Grade Analysis Method : 8.5Overall Column Height Top & Bottom FixityAllowable Strength Fy : Steel Yield ksi Steel Section Name :HSS6x6x1/2 46.0 ft E : Elastic Bending Modulus .Applied Loads Service loads entered. Load Factors will be applied for calculations. Column self weight included : 299.540 lbs * Dead Load Factor AXIAL LOADS . . . B3: Axial Load at 8.50 ft, D = 0.6520, LR = 0.8680 k B4: Axial Load at 8.50 ft, D = 0.5440, LR = 0.7260 k BENDING LOADS . . . Lat. Point Load at 8.50 ft creating Mx-x, E = 0.8040 k .DESIGN SUMMARY PASS Max. Axial+Bending Stress Ratio =0.1402 Location of max.above base 0.0 ft 1.799 k 268.287 k -6.219 k-ft Load Combination +1.203D+0.910E Load Combination +1.203D+0.910E 45.449 k-ft Bending & Shear Check Results PASS Maximum Shear Stress Ratio = 0.7316 k 0.01034 : 1 Location of max.above base 0.0 ft At maximum location values are . . . : 1 At maximum location values are . . . k 45.449 k-ft 0.0 k-ft Pa : Axial Pn / Omega : Allowable Ma-x : Applied Mn-x / Omega : Allowable Ma-y : Applied Mn-y / Omega : Allowable Va : Applied Vn / Omega : Allowable Maximum Load Reactions . . Top along X-X 0.0 k Bottom along X-X 0.0 k Top along Y-Y 0.0 k Bottom along Y-Y 0.8040 k Maximum Load Deflections . . . Along Y-Y 0.2020 in at 8.50 ft above base for load combination :E Only Along X-X 0.0 in at 0.0 ft above base for load combination : 70.779 . Maximum Axial + Bending Stress Ratios Maximum Shear Ratios Load Combination Stress Ratio Location Stress Ratio Status LocationStatus Load Combination Results Cbx Cby KxLx/Rx KyLy/Ry D Only PASS PASS0.00 0.000 0.00 ftft0.006 1.00 1.00 0.00 0.00 +D+Lr PASS PASS0.00 0.000 0.00 ftft0.012 1.00 1.00 0.00 0.00 +D+0.750Lr PASS PASS0.00 0.000 0.00 ftft0.010 1.00 1.00 0.00 0.00 +0.60D PASS PASS0.00 0.000 0.00 ftft0.003 1.00 1.00 0.00 0.00 +1.203D+0.910E PASS PASS0.00 0.010 0.00 ftft0.140 1.00 1.00 0.00 0.00 +1.203D-0.910E PASS PASS0.00 0.010 0.00 ftft0.140 1.00 1.00 0.00 0.00 +1.152D+0.6825E PASS PASS0.00 0.008 0.00 ftft0.106 1.00 1.00 0.00 0.00 +1.152D-0.6825E PASS PASS0.00 0.008 0.00 ftft0.106 1.00 1.00 0.00 0.00 +0.3970D+0.910E PASS PASS0.00 0.010 0.00 ftft0.138 1.00 1.00 0.00 0.00 +0.3970D-0.910E PASS PASS0.00 0.010 0.00 ftft0.138 1.00 1.00 0.00 0.00 . k k-ft Note: Only non-zero reactions are listed. Load Combination X-X Axis Reaction Y-Y Axis ReactionAxial Reaction @ Base @ Top@ Base @ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top Mx - End Moments My - End Moments D Only 1.496 +D+Lr 3.090 +D+0.750Lr 2.691 122 Steel Column LIC# : KW-06017148, Build:20.24.10.30 CASTILLO ENGINEERING INC.(c) ENERCALC, LLC 1982-2025 DESCRIPTION:C1* Project File: 25-132.ec6 Project Title: Engineer: k k-ft Note: Only non-zero reactions are listed. Load Combination X-X Axis Reaction Y-Y Axis ReactionAxial Reaction @ Base @ Top@ Base @ Base @ Top Maximum Reactions @ Base @ Base@ Top @ Top Mx - End Moments My - End Moments +0.60D 0.897 +D+0.70E 1.496 0.563 -4.784 +D+0.5250E 1.496 0.422 -3.588 +0.60D+0.70E 0.897 0.563 -4.784 Lr Only 1.594 E Only 0.804 -6.834 k k-ft Item X-X Axis Reaction Y-Y Axis ReactionAxial Reaction @ Base @ Top@ Base @ Base @ Top Extreme Reactions Extreme Value @ Base @ Base@ Top @ Top Mx - End Moments My - End Moments MaximumAxial @ Base 3.090 Minimum"0.804 -6.834 MaximumReaction, X-X Axis Base 1.496 Minimum"1.496 MaximumReaction, Y-Y Axis Base 0.804 -6.834 Minimum"1.496 MaximumReaction, X-X Axis Top 1.496 Minimum"1.496 MaximumReaction, Y-Y Axis Top 1.496 Minimum"1.496 MaximumMoment, X-X Axis Base 1.496 Minimum"0.804-6.834 -6.834 MaximumMoment, Y-Y Axis Base 1.496 Minimum"1.496 MaximumMoment, X-X Axis Top 1.496 Minimum"1.496 MaximumMoment, Y-Y Axis Top 1.496 Minimum"1.496 .Maximum Deflections for Load Combinations Max. Deflection in X dir Max. Deflection in Y dir DistanceLoad Combination Distance D Only 0.0000 0.000 0.0000.000 0.0000 0.000 0.0000.000 0.0000 0.000 0.0000.000 0.0000 0.000 0.0000.000 0.0000 0.141 8.5000.000 0.0000 0.106 8.5000.000 0.0000 0.141 8.5000.000 0.0000 0.000 0.0000.000 0.0000 0.200 8.4430.000 .Steel Section Properties :HSS6x6x1/2 R xx = 2.230 in Depth =6.000 in R yy = 2.230 in J =81.100 in^4 Width =6.000 in Wall Thick = 0.500 in Zx =19.800 in^3 Area = 9.740 in^2 Weight =35.240 plf I xx =48.30 in^4 S xx =16.10 in^3Design Thick =0.465 in I yy =48.300 in^4 C =28.100 in^3 S yy =16.100 in^3 Ycg =0.000 in 123 Steel Column LIC# : KW-06017148, Build:20.24.10.30 CASTILLO ENGINEERING INC.(c) ENERCALC, LLC 1982-2025 DESCRIPTION:C1* Project File: 25-132.ec6 Project Title: Engineer: Sketches 124 CASTILLO ENGINEERING INC. 1205 Pine Avenue, Suite 201 Long Beach, CA 90813 Vertical Distribution of Seismic Forces (ASCE7-16 12.8.3)Diaphragm Design Forces (ASCE7-16 12.10.1.1) 1.29 0.198 1 base=11.5 kips R=6.5 Wo=2.5 No. of levels=2 T=0.189 sec k= 1 Vertical Distribution of Base Shear Diaphragm Forces Level x hx^k Wx SWi Wxhx^k Cvx=Wxhx^K/Swihi^k Fx=Cvx*V Fx/Wx=sa SVx Wpx SFx/SWi Fpx Fpx(max.)Fpx(min.)Fpx coeff. 2 16 24.01 24.01 1 8 33.83 33.83 S 2 57.84 655 1.000 11 57.84 125 CASTILLO ENGINEERING INC. 1205 Pine Avenue, Suite 201 Long Beach, CA 90813 T:562-961-5600 F:562-961-5700 Direction-X DIR Diaphragm span L1 19 ft Unit load u1 13.6 psf Diaphragm depth d1 19 ft DIA-1 w1=0.258 klf d1 19 ft d1 19 ft V1=2.45 k 19 ft V2=-2.45 k R=2.45 2.45 Shear v1=2.45119 =129 plf va=215 plf OK 19 v2=2.45119 =129 plf va=215 plf OK 19 Chords M1=11.64 k-ft T1=11.64 =0.61 k Ta=1.25 k OK 19.00 Use:3/4" Struct-1 w/ 10d nails @ 6,6,12 , 2x members (unblocked) Use:TYPE 6 SLPICE 2-2x4 MIN. TOP PLATES -3 -2 -1 0 1 2 3 126 CASTILLO ENGINEERING INC. 1205 Pine Avenue, Suite 201 Long Beach, CA 90813 T:562-961-5600 F:562-961-5700 Direction-Y DIR Diaphragm span L1 19 ft Unit load u1 13.6 psf Diaphragm depth d1 19 ft DIA-1 w1=0.258 klf d1 19 ft d1 19 ft V1=2.45 k 19 ft V2=-2.45 k R=2.45 2.45 Shear v1=2.45119 =129 plf va=215 plf OK 19 v2=2.45119 =129 plf va=215 plf OK 19 Chords M1=11.64 k-ft T1=11.64 =0.61 k Ta=1.25 k OK 19.00 Use:3/4" Struct-1 w/ 10d nails @ 6,6,12 , 2x members (unblocked) Use:TYPE 6 SLPICE 2-2x4 MIN. TOP PLATES -3 -2 -1 0 1 2 3 127 CASTILLO ENGINEERING INC. 1205 Pine Avenue, Suite 201 Long Beach, CA 90813 T:562-961-5600 F:562-961-5700 Direction-X DIR Diaphragm span L1 15.5 ft Unit load u1 13.6 psf Diaphragm depth d1 11.3 ft DIA-1 w1=0.154 klf d1 11.3333 ft d1 11.333 ft V1=1.19 k 15.5 ft V2=-1.19 k R=1.19 1.19 Shear v1=1.19277 =105 plf va=215 plf OK 11.3333 v2=1.19277 =105 plf va=215 plf OK 11.3333 Chords M1=4.62 k-ft T1=4.62 =0.41 k Ta=1.25 k OK 11.33 Use:3/4" Struct-1 w/ 10d nails @ 6,6,12 , 2x members (unblocked) Use:TYPE 6 SLPICE 2-2x4 MIN. TOP PLATES -1.5 -1 -0.5 0 0.5 1 1.5 128 CASTILLO ENGINEERING INC. 1205 Pine Avenue, Suite 201 Long Beach, CA 90813 T:562-961-5600 F:562-961-5700 Direction-Y DIR Diaphragm span L1 11.3 ft Unit load u1 13.6 psf Diaphragm depth d1 15.5 ft DIA-1 w1=0.210 klf d1 15.5 ft d1 15.5 ft V1=1.19 k 11.3 ft V2=-1.19 k R=1.19 1.19 Shear v1=1.19274 =77 plf va=215 plf OK 15.5 v2=1.19274 =77 plf va=215 plf OK 15.5 Chords M1=3.38 k-ft T1=3.38 =0.22 k Ta=1.25 k OK 15.50 Use:3/4" Struct-1 w/ 10d nails @ 6,6,12 , 2x members (unblocked) Use:TYPE 6 SLPICE 2-2x4 MIN. TOP PLATES -1.5 -1 -0.5 0 0.5 1 1.5 129 Certificate of Compliance Payment of School Facility Fees Santa Ana Unified School District CITY OF SANTA ANA Planning and Building Agency A 52d 6 pPr FOR PERMIT ISSUANCE Name (First, MI, Last) Telephone Master ID: Aldo A -Ttane++ee Gasielan --fla--a P*4- 4S Project Address Tract/Parcel Number 5 29 N fit. Anne -Pl , Z iO1123-412 City, State, 'Lip Code San -fa Ana, CA g2104 Name (First, MI, Last) Use of Building (check) Residential Commercial ❑ Senior Housing ❑ Description of Project New Afbched ADU Number of Square Feet of —+ E3 y Residential Space Number of Square Feet of Commercial Space Telephone Type of Project (check) New 9 Addition ❑ Alteration ❑ Sq.Ft x $ S X+ (Dev. Fee) Sq.Ft x $ (Dev. Fee) Total $ 4,053.28 Total S The above representations as to square footage are true. Applicant agrees that if it is later determined that such representations are not true, then this certificate shall automatically terminate, and the appropriate City/County shall be notified. Applicant is hereby noticed that any party tiling a protest regarding the imposition of fees pursuant to Government Code Section 53080 must do so within 90 days from the payment of the fee. eDucxclaiu pe 4ernanc ez, �ep� 25 Z5 Applicant Name (Please Print) Date I Signature This certifies that the above -named Applicant has paid school facility fees in compliance with all existing and applicable sections of the Gover t Code and Education Code. t, Santa Ana 4i&d School Distric Authorized epresentative Date DISTRIBUTION White - CinXounn, Canan- -Applicant Pink - Facilities Page 1 of 1 EXISTING ONE & TWO FAMILY DWELLINGS ELECTRICAL SERVICES UNDERGROUND EXCEPTION CEC 2022 ELC-04 All new utility connections are required to be installed below grade by Santa Ana Municipal Code 41- 626(b). There is a standing exception for one and two family dwellings. This exception applies only when the new electrical service is designed to be fed from below grade as well as overhead. This diagram is a typical unit. The utility is able to feed this cabinet from the top or the bottom without interfering with the distribution wiring. All the circuit breakers and branch circuits are contained in the circuit breaker side of this cabinet. Only listed combination overhead and underground feed service boxes may be used to connect to an overhead utility drop. This exception to an underground fed service applies only to existing single family and two family residences. Planning & Building Agency Permits & Plan Check Section 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 Rigid Conduit Service Entrance Conductor Riser Underground Service Lateral METER Rev. 1/21/2020