Loading...
HomeMy WebLinkAbout1334 N Santiago St - PlanDE F DE F DEF DE F X Drawn / Checked by: Date: Scale: Drawing Title: No. Lo c a t i o n : P: \ S C F u e l \ 1 3 3 4 S a n t i a g o S t , S a n t a A n a \ S u b m i t t a l s \ 2 0 2 5 - 0 8 2 8 - R e s u b m i t t a l \ 2 0 2 5 - 0 8 - 2 8 _ S C F u e l s - S a n t a A n a P C C 3 \ S a n t a A n a - D E F . 1 . d w g - Pl o t D a t e : 8/ 2 8 / 2 0 2 5 8 : 4 2 : 5 0 A M F: 800-342-0507 5932 Bolsa Avenue, Ste. #107 Huntington Beach, CA 92649 714-892-8810 'PIKPGGTKPI %QPUVTWEVKQP 714-892-8812T: Stamp: $6L'HYHORSPHQW‹H[SUHVVO\UHVHUYHVDOO common law copyright and property right in these plans. These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to assigned to any third party without first obtaining the express written permission and consent of ASi Development. Project No.: Sheet: - DP No.: - Date Description 1 10/17/2024 PCC 01 2 01/01/2025 PCC 02 3 06/12/2025 PCC 03 4 08/28/2025 PCC 04 GENERAL NOTES 1.SITE ADDRESS MUST BE VISIBLE FROM STREET. 2.ELECTRICAL WIRING AND EQUIPMENT SHALL MEET ELECTRICAL CODE REQUIREMENTS. 3.ALL EQUIPMENT SHALE BE APPROVED & LISTED FOR THE PROPOSED USE. 4.SIGNS PROHIBITING SMOKING AND OPEN FLAMES SHALL BE POSTED AND CLEARLY VISIBLE. 5.PIPING VALVES AND FITTINGS SHALL BE APPROVED AND LISTED FOR THE SPECIFIC APPLICATION BEING PROPOSED. 6.NON-CORROSIVE OR CORROSION PROTECTED MATERIALS SHALL BE PROVIDED TO AVOID GALVANIC ACTION OF DISSIMILAR METALS. 7.PIPE JOINTS SHALL BE LIQUID TIGHT AND PER MANUFACTURER'S LISTING. 8.STORAGE TANKS SHALL BE TESTED INDEPENDENTLY FROM THE PIPING. 9.DISPENSER PROTECTION SHALL BE BY A CONCRETE ISLAND 6 INCHES OR CONCRETE BOLLARDS . 10.ALL EQUIPMENT SHALL BE APPROVED AND LISTED FOR THE PROPOSED USE. 11.BREAKAWAY DEVICES SHALL BE DESIGNED TO RETAIN LIQUIDS ON BOTH SIDES OF THE BREAKAWAY POINT. 12.NOZZLES SHALL BE AUTOMATIC-CLOSING TYPE AND SHALL MEET MANUFACTURER'S AND CODE REQUIREMENTS. 13.PIPING TESTS: 150 PERCENT OF MAXIMUM ANTICIPATED PRESSURE HYDROSTATICALLY OR 110 PERCENT OF MAXIMUM ANTICIPATED PRESSURE PNEUMATICALLY BUT NOT LESS THAN 5 PSIG AT THE HIGHEST POINT. 14.DISPENSER TO BE SECURED IN APPROVAL MANNER PER MFR. & LOCAL JURISDICTION SPECIFICATIONS. 15.ALL DESIGN AND PLANS BASED ON THE 2022 CBC, CMC, AND ASCE-10 AND ACI 318-14. 1334 SANTIAGO ST., SANTA ANA, CA 92702 SC FUELS GRAPHIC SCALE: 1" = 0 40'60'20'20'10' 20' SITE PLAN VICINITY MAP PE N N W A Y PROJECT SITE THIS SITE PLAN HAS BEEN PREPARED WITHOUT THE BENEFIT OF A TITLE REPORT, SITE SURVEY OR PRELIMINARY INVESTIGATION WITH THE AUTHORITIES HAVING JURISDICTION. NOTE: SCOPE OF WORK 1.INSTALL (1) NEW ABOVE GROUND 2,000 GALLON " BLUE 1 USA" MINI-BULK HDPE SINGLE WALL WITHIN EXTERIOR SHELL INSULATED FRP PANELS LEAK TIGHT HOUSING ABOVEGROUND TANK COMPLETED WITH TANK TOP EQUIPMENT (OVERFILL ALARM,OVERFILL PREVENTION VALVE, INTERSTITIAL SENSOR, TANK LEVEL PROBE, SUBMERSIBLE PUMP. 2.INSTALL (2) NEW "BENNETT" DEF DISPENSER. 3.INSTALL "DEF" COMPATIBLE DISPENSER HANGING HARDWARE & PIPING. 4.INSTALL "OMEGAFLEX" DOUBLE WALL FLEXIBLE PIPING SYSTEM WITH OPW DUCT PIPING 4" DIA. / CASE PIPING TO NEW DISPENSERS. 5.AUTHORITY HAVING JURISDICTION TO BE ON-SITE FOR PIPING PRESSURE TEST PRIOR TO BACKFILL (IF REQUIRED PER PERMIT). 6.INSTALL (1) NEW DEF AST TANK SLAB 7.CONTRACTOR TO TRENCH AND INSTALL 1" CONDUIT FOR LOW VOLTAGE FROM VEDEER-ROOT PANEL TO EXISTING MODULAR BUILDING. 8.INSTALL 8' HIGH CHAIN LINK FENCE WITH PRIVACY SLATS OR SCREEN MESH. SHEET INDEX CLIENT & AGENT PROJECT TEAM I-5 F W Y EXISTING CONCRETE BOLLARD (TYP.) (N) BENNETT DEF DISPENSER (FIRST) SEE DETAIL 1 ON DEF.3 FOR DISPENSER SIDE REACH DETAIL & DETAIL 2 FOR ANCHORING. EXISTING YARD LIGHT (TYP.) EXISTING DISPENSER (TYP.) 16'-5" EXISTING ISLAND (TYP.) PT 1"-0" = 20'-0" COVER SHEET & SITE PLAN P/L LIMITS OF WORK SA N T I A G O S T . E. WASHINGTON AVE. EXISTING U.G. TANK EXISTING BUILDING EXISTING STORAGE AREA “ 2' - 6 " 21 ' - 1 1 " 3' - 1 0 " EXISTING U.G. TANK (TYP.) (N) BENNETT DEF DISPENSER (SECOND) ON EXISTING CONCRETE ISLAND . SEE DETAIL 2 ON DEF.3 FOR ANCHORING. EXISTING CMU WALL ALONG P/L R/W R/W EXISTING CONCRETE PAVEMENT EXISTING CONCRETE PAVEMENT EXISTING POS (TYP.) EXISTING BUILDING 8'-10" 1 APPLICABLE CODES CALIFORNIA BUILDING CODE:2022 CALIFORNIA MECHANICAL CODE: 2022 CALIFORNIA PLUMBING CODE: 2022 CALIFORNIA ELECTRICAL CODE: 2022 1 6' 8'-10" (N) 2,000 GALLON DEF AST SEE DETAIL 2 ON SHEET DEF.2 & DEF.3 FOR ADDITIONAL INFORMATION NEW UNDERGROUND OMEGAFLEX PIPING WITH OPW DUCT PIPING, 4" DIA. DUCT / CASE PIPING 2 3 3 3 3'-0" ‘&21&5(7( FOOTING 2'-6" CLEAR 3' , T Y P PANIC HARDWARE HOOVER FENCE CO. D-6045 SURFACE MOUNT EXIT BAR - SUPERIOR KIT WITH LOCK BOX, OR APPROVED EQUAL MOUNTING PLATE 8' - 0 " LOCKABLE LATCH LOCK BOX GATE LATCH PROTECTOR TO PREVENT INTRUSION FENCE NOTES: 1.SECURE DRIVE-FIT GALVANIZED CAP TO POST WITH 1/4" ROUND-HEAD RIVET. 2.STEEL BANDS AT TENSION BARS SHALL BE 1/8" X 1" MINIMUM, SPACED AT MAXIMUM 16" O.C. 3.CORNER POSTS SHALL BE USED WHERE FENCE LINE '()/(&7,21*5($7(57+$1ƒ 4.ALL GATES SHALL BE LOCKABLE. 5.ALL PEDESTRIAN ACCESS GATES SHALL HAVE A SURFACE MOUNTED PANIC BAR INSTALLED. A. HARDWARE SHALL BE INSTALLED 36" ABOVE FINISHED GRADE. B. KEYED ENTRY IS REQUIRED AT ALL PEDESTRIAN GATES. 6.FENCE FINISH SHALL BE GALVANIZED CHAIN LINK COATED FENCE 2" DIAMOND, 9 GAUGE WIRE, GALVANIZED POSTS, GATE FRAME, AND HARDWARE. 7.POST SPACING SHALL BE A MAXIMUM OF 8'-0" O.C. 8.NOMINAL FENCE HEIGHT SHALL BE 8'-0" MIN. ABOVE FINISHED SURFACE, AND TOP OF FENCE SHALL BE UNIFORM ALONG THE ENTIRE FENCE LINE. Drawn / Checked by: Date: Scale: Drawing Title: No. Lo c a t i o n : P: \ S C F u e l \ 1 3 3 4 S a n t i a g o S t , S a n t a A n a \ S u b m i t t a l s \ 2 0 2 5 - 0 8 2 8 - R e s u b m i t t a l \ 2 0 2 5 - 0 8 - 2 8 _ S C F u e l s - S a n t a A n a P C C 3 \ S a n t a A n a - D E F . 4 . d w g - Pl o t D a t e : 8/ 2 8 / 2 0 2 5 8 : 4 5 : 0 6 A M F: 800-342-0507 5932 Bolsa Avenue, Ste. #107 Huntington Beach, CA 92649 714-892-8810 'PIKPGGTKPI %QPUVTWEVKQP 714-892-8812T: Stamp: $6L'HYHORSPHQW‹H[SUHVVO\UHVHUYHVDOO common law copyright and property right in these plans. These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to assigned to any third party without first obtaining the express written permission and consent of ASi Development. Project No.: Sheet: - DP No.: - Date Description 1 10/17/2024 PCC 01 2 01/01/2025 PCC 02 3 06/12/2025 PCC 03 4 08/28/2025 PCC 04 LOCKING MECHANISM, PUSH PANIC HARDWARE, AND KICK PLATE SHALL BE PROVIDED ON WALK GATE. 3'-0" PEDESTRIAN ACCESS GATEPEDESTRIAN ACCESS GATE 01 3 CHAIN LINK FENCE & GATE DETAILS 02 10'-0" O.C. MAX SPACING 4 NON HAZARDOUS NFPA PLACARD Drawn / Checked by: Date: Scale: Drawing Title: No. Lo c a t i o n : P: \ S C F u e l \ 1 3 3 4 S a n t i a g o S t , S a n t a A n a \ S u b m i t t a l s \ 2 0 2 5 - 0 8 2 8 - R e s u b m i t t a l \ 2 0 2 5 - 0 8 - 2 8 _ S C F u e l s - S a n t a A n a P C C 3 \ S a n t a A n a - D E F . 2 . d w g - Pl o t D a t e : 8/ 2 8 / 2 0 2 5 8 : 4 9 : 3 2 A M F: 800-342-0507 5932 Bolsa Avenue, Ste. #107 Huntington Beach, CA 92649 714-892-8810 'PIKPGGTKPI %QPUVTWEVKQP 714-892-8812T: Stamp: $6L'HYHORSPHQW‹H[SUHVVO\UHVHUYHVDOO common law copyright and property right in these plans. These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to assigned to any third party without first obtaining the express written permission and consent of ASi Development. Project No.: Sheet: - DP No.: - Date Description 1 10/17/2024 PCC 01 2 01/01/2025 PCC 02 3 06/12/2025 PCC 03 4 08/28/2025 PCC 04 CONSTRUCTION NOTES 7 3 8 9 10 PT SEE PLAN 1 NEW DISPENSER ON EXISTING ISLAND 2 4 5 DEF CONNECT @ DISPENSER (SECOND DISPENSER) DISPENSER DEF EQUIPMENT TANK PIPING & MISC. 1 2 3 DEF SITE PLAN & DETAILS 3 4 Drawn / Checked by: Date: Scale: Drawing Title: No. Lo c a t i o n : P: \ S C F u e l \ 1 3 3 4 S a n t i a g o S t , S a n t a A n a \ S u b m i t t a l s \ 2 0 2 5 - 0 8 2 8 - R e s u b m i t t a l \ 2 0 2 5 - 0 8 - 2 8 _ S C F u e l s - S a n t a A n a P C C 3 \ S a n t a A n a - D E F . 3 . d w g - Pl o t D a t e : 8/ 2 8 / 2 0 2 5 8 : 4 4 : 1 6 A M F: 800-342-0507 5932 Bolsa Avenue, Ste. #107 Huntington Beach, CA 92649 714-892-8810 'PIKPGGTKPI %QPUVTWEVKQP 714-892-8812T: Stamp: $6L'HYHORSPHQW‹H[SUHVVO\UHVHUYHVDOO common law copyright and property right in these plans. These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to assigned to any third party without first obtaining the express written permission and consent of ASi Development. Project No.: Sheet: - DP No.: - Date Description 1 10/17/2024 PCC 01 2 01/01/2025 PCC 02 3 06/12/2025 PCC 03 4 08/28/2025 PCC 04 NOTE: 1.TOTAL MAX WEIGHT OF 1,000 GALLON AST WHEN FULLY LOADED (100%) 21,500 LBS. 2.THE DOOR POSITION CAN BE SELECTED ON THE SIDE OR FRONT OF UNIT. 1 ISLAND GROUND EXCEPTION: OPERABLE PARTS OF FUEL DISPENSER SHALL BE PERMITTED TO BE 54" MAX.MEASURED FROM THE SURFACE OF THE VEHICULAR WAY WHERE FUEL DISPENSER ARE INSTALLED ON EXISTING CURB. 2,000 GAL. DEF TANK PLAN & SECTIONS 1 2 3 STRUCTURAL CALCULATIONS SC Fuels Site Structures 1334 N. Santiago Street Santa Ana, CA JKL Project No. 25101 June 27, 2025 Phone: (626) 524-2210 Email: Mail@JKLStructural.com Per ASCE 7-22 13.3.1 Seismic Demands on Nonstructural Components HfCAR RμRpo Ip =1.5 SDS = Wp =lbs Fp H = inches Rμ =1.3 (Eq. 13.3-6) H W = inches Rpo =1.5 (Table 13.5/6-1) L = inches z/h =0.0 Hf =1.0 (Eq. 13.3-5) CAR =1.0 (Table 13.5/6-1) W or L Ωop =2.0 Fp < 1.6 SDSIpWp = lbs Eq. 13.3-2 Fp > 0.3 SDSIpWp = lbs Eq. 13.3-3 Overturning Load = Fp x (H/2) x Ωop / (shorter dimension between W and L) + 0.2 Sds Wp ft-lbs Capacity of bolts/screws = lbs (1/2" dia Simpson Strongbolt 2 w/ 3.375" embed) Number of bolts/screws required = Use 2-1/2" dia Simpson Strongbolt 2 w/ 3.375" embed Sliding = lbs Capacity of bolts/screws = lbs (1/2" dia Simpson Strongbolt 2 Number of bolts/screws required = w/ 3.375" embed) Use 2-1/2" dia Simpson Strongbolt 2 w/ 3.375" embed Wind Design not required as Seismic Load governs by inspection. Fp = 3500 1.042 [ ]0.4SDSIpWp CALCS/SKETCHES By: JL Checked: Project : 1334 N. Santiago St (Dispenser) Project No: 25101 Date: 6/27/25 Page: 1641.2 1000.0 1.6 18.0 Eq. 13.3-1lbs 8752.8 1641.2 52.0 19.5 5470.5 3000.0 1.8 =1122.2 1 Company:Date:6/27/2025 Engineer:Page:1 Project: Address: Phone: E-mail: Anchor Designer™ for Concrete Software Version 3.3.2410.2 1.Project information Project description: Location: Design name: Design Comment: 2. Input Data & Anchor Parameters General Design method:ACI 318-19 Units: Imperial units Anchor Information: Anchor type: Torque controlled expansion anchor Material: Carbon Steel Diameter (inch): 0.500 Nominal Embedment depth (inch): 3.875 Effective Embedment depth, hef (inch): 3.375 Code report: ICC-ES ESR-3037 Anchor category: 1 Anchor ductility: Yes hmin (inch): 6.00 cac (inch): 7.50 Cmin (inch): 4.00 Smin (inch): 2.75 Base Material Concrete: Normal-weight Concrete thickness, h (inch): 13.78 State: Cracked Compressive strength, f’c (psi): 2500 Ψc,V: 1.0 Reinforcement condition: B tension, B shear Supplemental edge reinforcement: Not applicable Reinforcement provided at corners: No Ignore concrete breakout in tension: No Ignore concrete breakout in shear: No Ignore 6do requirement: Not applicable Build-up grout pad: No Recommended Anchor Anchor Name: Strong-Bolt® 2 - 1/2"Ø STB2, hnom:3.875" (98mm) Code Report: ICC-ES ESR-3037 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc.5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com Company:Date:6/27/2025 Engineer:Page:2 Project: Address: Phone: E-mail: Anchor Designer™ for Concrete Software Version 3.3.2410.2 Load and Geometry Load factor source: ACI 318 Section 5.3 Load combination: not set Seismic design: No Anchors subjected to sustained tension: Not applicable Apply entire shear load at front row: Yes Anchors only resisting wind and/or seismic loads: No Strength level loads: Nua [lb]: 3000 Vuax [lb]: 1000 Vuay [lb]: 0 <Figure 1> Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc.5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com Company:Date:6/27/2025 Engineer:Page:3 Project: Address: Phone: E-mail: Anchor Designer™ for Concrete Software Version 3.3.2410.2 <Figure 2> 3. Resulting Anchor Forces Anchor Tension load, Nua (lb) Shear load x, Vuax (lb) Shear load y, Vuay (lb) Shear load combined, √(Vuax)²+(Vuay)² (lb) 1 3000.0 1000.0 0.0 1000.0 Sum 3000.0 1000.0 0.0 1000.0 Maximum concrete compression strain (‰): 0.00 Maximum concrete compression stress (psi): 0 Resultant tension force (lb): 3000 Resultant compression force (lb): 0 Eccentricity of resultant tension forces in x-axis, e'Nx (inch): 0.00 Eccentricity of resultant tension forces in y-axis, e'Ny (inch): 0.00 Eccentricity of resultant shear forces in x-axis, e'Vx (inch): 0.00 Eccentricity of resultant shear forces in y-axis, e'Vy (inch): 0.00 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc.5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com Company:Date:6/27/2025 Engineer:Page:4 Project: Address: Phone: E-mail: Anchor Designer™ for Concrete Software Version 3.3.2410.2 4. Steel Strength of Anchor in Tension (Sec. 17.6.1) Nsa (lb)Nsa (lb) 12100 0.75 9075 5. Concrete Breakout Strength of Anchor in Tension (Sec. 17.6.2) Nb = kc a f’chef1.5 (Eq. 17.6.2.2.1) kc a f’c (psi)hef (in)Nb (lb) 17.0 1.00 2500 3.375 5270 Ncb =(ANc / ANco)ed,N c,N cp,NNb (Sec. 17.5.1.2 & Eq. 17.6.2.1a) ANc (in2)ANco (in2)ca,min (in)ed,N c,N cp,N Nb (lb)Ncb (lb) 102.52 102.52 6.00 1.000 1.00 1.000 5270 0.65 3426 6. Pullout Strength of Anchor in Tension (Sec. 17.6.3) Npn =c,P aNp(f’c /2,500)n (Sec. 17.5.1.2, Eq. 17.6.3.1 & Code Report) c,P a Np (lb)f’c (psi)n Npn (lb) 1.0 1.00 4985 2500 0.50 0.65 3240 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc.5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com Company:Date:6/27/2025 Engineer:Page:5 Project: Address: Phone: E-mail: Anchor Designer™ for Concrete Software Version 3.3.2410.2 8. Steel Strength of Anchor in Shear (Sec. 17.7.1) Vsa (lb)grout grout Vsa (lb) 7235 1.0 0.65 4703 9. Concrete Breakout Strength of Anchor in Shear (Sec. 17.7.2) Shear perpendicular to edge in x-direction: Vbx =min|7(le / da)0.2 da a f’cca11.5; 9 a f’cca11.5| (Eq. 17.7.2.2.1a & Eq. 17.7.2.2.1b) le (in)da (in)a f’c (psi)ca1 (in)Vbx (lb) 3.38 0.500 1.00 2500 6.00 5329 V cbx =(AVc / AVco)ed,V c,V h,VVbx (Sec. 17.5.1.2 & Eq. 17.7.2.1a) AVc (in2)AVco (in2)ed,V c,V h,V Vbx (lb)Vcbx (lb) 162.00 162.00 1.000 1.000 1.000 5329 0.70 3730 10. Concrete Pryout Strength of Anchor in Shear (Sec. 17.7.3) Vcp =kcpNcb =kcp(ANc / ANco)ed,N c,N cp,NNb (Sec. 17.5.1.2 & Eq. 17.7.3.1a) kcp ANc (in2)ANco (in2)ed,N c,N cp,N Nb (lb)Vcp (lb) 2.0 102.52 102.52 1.000 1.000 1.000 5270 0.70 7378 11. Results Interaction of Tensile and Shear Forces (Sec. R17.8) Tension Factored Load, Nua (lb)Design Strength, øNn (lb)Ratio Status Steel 3000 9075 0.33 Pass Concrete breakout 3000 3426 0.88 Pass Pullout 3000 3240 0.93 Pass (Governs) Shear Factored Load, Vua (lb)Design Strength, øVn (lb)Ratio Status Steel 1000 4703 0.21 Pass T Concrete breakout x+ 1000 3730 0.27 Pass (Governs) Pryout 1000 7378 0.14 Pass Interaction check (Nua/ɸNua)5/3 (Vua/ɸVua)5/3 Utilization Ratio Permissible Status Sec. R17.8 0.88 0.11 99.1% 1.0 Pass 1/2"Ø STB2, hnom:3.875" (98mm) meets the selected design criteria. 12. Warnings - Designer must exercise own judgement to determine if this design is suitable. - Refer to manufacturer’s product literature for hole cleaning and installation instructions. Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc.5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com Per ASCE 7-22 13.3.1 Seismic Demands on Nonstructural Components HfCAR RμRpo Ip =1.5 SDS = Wp =lbs Fp H = inches Rμ =1.3 (Eq. 13.3-6) H W = inches Rpo =1.5 (Table 13.5/6-1) L = inches z/h =0.0 Hf =1.0 (Eq. 13.3-5) CAR =1.0 (Table 13.5/6-1) W or L Ωop =2.0 Fp < 1.6 SDSIpWp = lbs Eq. 13.3-2 Fp > 0.3 SDSIpWp = lbs Eq. 13.3-3 Overturning Load = Fp x (H/2) x Ωop / (shorter dimension between W and L) + 0.2 Sds Wp ft-lbs Capacity of bolts/screws = lbs (3/4" dia Simpson Strongbolt 2 w/ 5" embed) Number of bolts/screws required = Use 3/4" dia Simpson Strongbolt 2 w/ 5" embed at 16" o.c. Sliding = lbs Capacity of bolts/screws = lbs (3/4" dia Simpson Strongbolt 2 w/ 5" embed) Number of bolts/screws required = Use 3/4" dia Simpson Strongbolt 2 w/ 5" embed at 16" o.c. Wind Design not required as Seismic Load governs by inspection. 7.7 20162.7 4500.0 4.5 197.0 107534.4 20162.7 34825.1 4500.0 lbs Eq. 13.3-1 1.042 43000 93.0 72.5 Date: 6/27/25 Page: Fp = 0.4SDSIpWp [ ] =13786 Project : 1334 N. Santiago St (Mini-bulk Storage) Project No: 25101 CALCS/SKETCHES By: JL Checked: 1 Company:Date:6/27/2025 Engineer:Page:1 Project: Address: Phone: E-mail: Anchor Designer™ for Concrete Software Version 3.3.2410.2 1.Project information Project description: Location: Design name: Design Comment: 2. Input Data & Anchor Parameters General Design method:ACI 318-19 Units: Imperial units Anchor Information: Anchor type: Torque controlled expansion anchor Material: Carbon Steel Diameter (inch): 0.750 Nominal Embedment depth (inch): 5.750 Effective Embedment depth, hef (inch): 5.000 Code report: ICC-ES ESR-3037 Anchor category: 1 Anchor ductility: Yes hmin (inch): 8.75 cac (inch): 8.00 Cmin (inch): 4.25 Smin (inch): 3.50 Base Material Concrete: Normal-weight Concrete thickness, h (inch): 13.78 State: Cracked Compressive strength, f’c (psi): 2500 Ψc,V: 1.0 Reinforcement condition: B tension, B shear Supplemental edge reinforcement: Not applicable Reinforcement provided at corners: No Ignore concrete breakout in tension: No Ignore concrete breakout in shear: No Ignore 6do requirement: Not applicable Build-up grout pad: No Recommended Anchor Anchor Name: Strong-Bolt® 2 - 3/4"Ø STB2, hnom:5.75" (146mm) Code Report: ICC-ES ESR-3037 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc.5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com Company:Date:6/27/2025 Engineer:Page:2 Project: Address: Phone: E-mail: Anchor Designer™ for Concrete Software Version 3.3.2410.2 Load and Geometry Load factor source: ACI 318 Section 5.3 Load combination: not set Seismic design: No Anchors subjected to sustained tension: Not applicable Apply entire shear load at front row: Yes Anchors only resisting wind and/or seismic loads: Yes Strength level loads: Nua [lb]: 4500 Vuax [lb]: 4500 Vuay [lb]: 0 <Figure 1> Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc.5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com Company:Date:6/27/2025 Engineer:Page:3 Project: Address: Phone: E-mail: Anchor Designer™ for Concrete Software Version 3.3.2410.2 <Figure 2> 3. Resulting Anchor Forces Anchor Tension load, Nua (lb) Shear load x, Vuax (lb) Shear load y, Vuay (lb) Shear load combined, √(Vuax)²+(Vuay)² (lb) 1 4500.0 4500.0 0.0 4500.0 Sum 4500.0 4500.0 0.0 4500.0 Maximum concrete compression strain (‰): 0.00 Maximum concrete compression stress (psi): 0 Resultant tension force (lb): 4500 Resultant compression force (lb): 0 Eccentricity of resultant tension forces in x-axis, e'Nx (inch): 0.00 Eccentricity of resultant tension forces in y-axis, e'Ny (inch): 0.00 Eccentricity of resultant shear forces in x-axis, e'Vx (inch): 0.00 Eccentricity of resultant shear forces in y-axis, e'Vy (inch): 0.00 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc.5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com Company:Date:6/27/2025 Engineer:Page:4 Project: Address: Phone: E-mail: Anchor Designer™ for Concrete Software Version 3.3.2410.2 4. Steel Strength of Anchor in Tension (Sec. 17.6.1) Nsa (lb)Nsa (lb) 29700 0.75 22275 5. Concrete Breakout Strength of Anchor in Tension (Sec. 17.6.2) Nb = kc a f’chef1.5 (Eq. 17.6.2.2.1) kc a f’c (psi)hef (in)Nb (lb) 17.0 1.00 2500 5.000 9503 Ncb =(ANc / ANco)ed,N c,N cp,NNb (Sec. 17.5.1.2 & Eq. 17.6.2.1a) ANc (in2)ANco (in2)ca,min (in)ed,N c,N cp,N Nb (lb)Ncb (lb) 180.00 225.00 6.00 0.940 1.00 1.000 9503 0.65 4645 6. Pullout Strength of Anchor in Tension (Sec. 17.6.3) Npn =c,P aNp(f’c /2,500)n (Sec. 17.5.1.2, Eq. 17.6.3.1 & Code Report) c,P a Np (lb)f’c (psi)n Npn (lb) 1.0 1.00 8500 2500 0.50 0.65 5525 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc.5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com Company:Date:6/27/2025 Engineer:Page:5 Project: Address: Phone: E-mail: Anchor Designer™ for Concrete Software Version 3.3.2410.2 8. Steel Strength of Anchor in Shear (Sec. 17.7.1) Vsa (lb)grout grout Vsa (lb) 14480 1.0 0.65 9412 9. Concrete Breakout Strength of Anchor in Shear (Sec. 17.7.2) Shear perpendicular to edge in x-direction: Vbx =min|7(le / da)0.2 da a f’cca11.5; 9 a f’cca11.5| (Eq. 17.7.2.2.1a & Eq. 17.7.2.2.1b) le (in)da (in)a f’c (psi)ca1 (in)Vbx (lb) 5.00 0.750 1.00 2500 6.00 6510 V cbx =(AVc / AVco)ed,V c,V h,VVbx (Sec. 17.5.1.2 & Eq. 17.7.2.1a) AVc (in2)AVco (in2)ed,V c,V h,V Vbx (lb)Vcbx (lb) 162.00 162.00 1.000 1.000 1.000 6510 0.70 4557 10. Concrete Pryout Strength of Anchor in Shear (Sec. 17.7.3) Vcp =kcpNcb =kcp(ANc / ANco)ed,N c,N cp,NNb (Sec. 17.5.1.2 & Eq. 17.7.3.1a) kcp ANc (in2)ANco (in2)ed,N c,N cp,N Nb (lb)Vcp (lb) 2.0 180.00 225.00 0.940 1.000 1.000 9503 0.70 10005 11. Results Interaction of Tensile and Shear Forces (Sec. 17.8) Tension Factored Load, Nua (lb)Design Strength, øNn (lb)Ratio Status Steel 4500 22275 0.20 Pass Concrete breakout 4500 4645 0.97 Pass (Governs) Pullout 4500 5525 0.81 Pass Shear Factored Load, Vua (lb)Design Strength, øVn (lb)Ratio Status Steel 4500 9412 0.48 Pass T Concrete breakout x+ 4500 4557 0.99 Pass (Governs) Pryout 4500 10005 0.45 Pass Interaction check Nua/Nn Vua/Vn Utilization Ratio Permissible Status Sec. 17.8.3 0.97 0.99 163.0% 1.0 Fail FAIL! Selected anchor type and embedment do not meet the selected design criteria. 12. Warnings - Designer must exercise own judgement to determine if this design is suitable. - Refer to manufacturer’s product literature for hole cleaning and installation instructions. Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc.5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com Wall Wind Loading per ASCE 7-16 29.3.1 Kz= qh=psf (ult) psf (asd) G= s= h= B= Cf=(Case A, B) Cf=(Case C) Reduction factor = 1.8-s/h = (Where s/h>0.8) Openings reduction = 1-(1-ratio)1.5 = ratio solid area to gross area = (ratio has to be less than 0.7) Cf=(Case C Avg) If B/s is greater than 2 then Case C applies: Case A, B: F= psf (ult) psf (asd) Case C: F= psf (ult) psf (asd) Use psf (ult) psf (asd) Case C applies 24.73 14.767 12.21 7.291 24.7 14.8 0.80 2.58 0.8 2.40 1.95 1.85 1 1.85 1.10 0.55 22.4 13.4 1 0.85 8.0 8.0 337 B/s = 1.3 Project : 1334 N. Santiago St (Fence) Project No: 25101 CALCS/SKETCHES 42.1 Date: 6/27/25 Page: 0.85 By: JL Checked: 1 Pole Footing Embedded in Soil LIC# : KW-06017733, Build:20.25.06.16 JASON LIN (c) ENERCALC, LLC 1982-2025 DESCRIPTION:Chainlink fence post Project File: 25101.ec6 Project Title: Engineer: Project ID: Project Descr: Code References Calculations per IBC 2024 1807.3 Load Combinations Used : ASCE 7-22 / IBC 2024 General Information Circular 12.0 275.0 1,500.0 Lateral Restraint at Ground Surface Pole Footing Shape Pole Footing Diameter . . . . . . . . . . .in Allow Passive . . . . . . . . . . . . . . . . . . . . . .pcf Max Passive . . . . . . . . . . . . . . . . . . . . . .psf Calculate Min. Depth for Allowable Pressures +0.60WGoverning Load Combination : Lateral Load 0.6660 Moment 2.664 k-ft Minimum Required Depth 3.50 ft k Restraint @ Ground Surface Pressure at Depth Actual 924.24 psf Allowable 962.50 psf Surface Restraint Force 2,283.43 lbs Controlling Values ft^2Footing Base Area 0.7854 Maximum Soil Pressure 0.0 ksf k k k k k Applied Loads k Lateral Concentrated Load (k) D : Dead Load L : Live Lr : Roof Live S : Snow W : Wind E : Earthquake H : Lateral Earth Load distance above k k k k k k k ft Lateral Distributed Loads (klf) TOP of Load above ground surface BOTTOM of Load above ground surface 0.1480 7.750 0.250 k/ft k/ft k/ft k/ft k/ft k/ft k/ft ft Applied Moment (kft) k-ft k-ft k-ft k-ft k-ft k-ft k-ft ground surface ft Vertical Load (k) k Load Combination Results Factor Soil IncreaseForces @ Ground Surface Load Combination Required Loads - (k)Moments - (ft-k)Depth - (ft) Pressure at Depth Allow - (psf)Actual - (psf) 0.00.000 0.000 0.13 1.00034.4 924.20.666 2.664+0.60W 3.50 1.000962.5 803.90.500 1.998+0.450W 3.25 1.000893.8 STRUCTURAL CALCULATIONS SC Fuels Site Structures 1334 N. Santiago Street Santa Ana, CA JKL Project No. 25101 June 27, 2025 Phone: (626) 524-2210 Email: Mail@JKLStructural.com Wall Wind Loading per ASCE 7-16 29.3.1 Kz= qh=psf (ult) psf (asd) G= s= h= B= Cf=(Case A, B) Cf=(Case C) Reduction factor = 1.8-s/h = (Where s/h>0.8) Openings reduction = 1-(1-ratio)1.5 = ratio solid area to gross area = (ratio has to be less than 0.7) Cf=(Case C Avg) If B/s is greater than 2 then Case C applies: Case A, B: F= psf (ult) psf (asd) Case C: F= psf (ult) psf (asd) Use psf (ult) psf (asd) Case C applies 24.73 14.767 12.21 7.291 24.7 14.8 0.80 2.58 0.8 2.40 1.95 1.85 1 1.85 1.10 0.55 22.4 13.4 1 0.85 8.0 8.0 337 B/s = 1.3 Project : 1334 N. Santiago St (Fence) Project No: 25101 CALCS/SKETCHES 42.1 Date: 6/27/25 Page: 0.85 By: JL Checked: 1 Pole Footing Embedded in Soil LIC# : KW-06017733, Build:20.25.06.16 JASON LIN (c) ENERCALC, LLC 1982-2025 DESCRIPTION:Chainlink fence post Project File: 25101.ec6 Project Title: Engineer: Project ID: Project Descr: Code References Calculations per IBC 2024 1807.3 Load Combinations Used : ASCE 7-22 / IBC 2024 General Information Circular 12.0 275.0 1,500.0 Lateral Restraint at Ground Surface Pole Footing Shape Pole Footing Diameter . . . . . . . . . . .in Allow Passive . . . . . . . . . . . . . . . . . . . . . .pcf Max Passive . . . . . . . . . . . . . . . . . . . . . .psf Calculate Min. Depth for Allowable Pressures +0.60WGoverning Load Combination : Lateral Load 0.6660 Moment 2.664 k-ft Minimum Required Depth 3.50 ft k Restraint @ Ground Surface Pressure at Depth Actual 924.24 psf Allowable 962.50 psf Surface Restraint Force 2,283.43 lbs Controlling Values ft^2Footing Base Area 0.7854 Maximum Soil Pressure 0.0 ksf k k k k k Applied Loads k Lateral Concentrated Load (k) D : Dead Load L : Live Lr : Roof Live S : Snow W : Wind E : Earthquake H : Lateral Earth Load distance above k k k k k k k ft Lateral Distributed Loads (klf) TOP of Load above ground surface BOTTOM of Load above ground surface 0.1480 7.750 0.250 k/ft k/ft k/ft k/ft k/ft k/ft k/ft ft Applied Moment (kft) k-ft k-ft k-ft k-ft k-ft k-ft k-ft ground surface ft Vertical Load (k) k Load Combination Results Factor Soil IncreaseForces @ Ground Surface Load Combination Required Loads - (k)Moments - (ft-k)Depth - (ft) Pressure at Depth Allow - (psf)Actual - (psf) 0.00.000 0.000 0.13 1.00034.4 924.20.666 2.664+0.60W 3.50 1.000962.5 803.90.500 1.998+0.450W 3.25 1.000893.8 Rahman Engineering Inc. A Civil / Structural & Environmental Engineering Services Company (Professional Engineer License # C69263, QSD/QSP # 22406) Rahman Engineering Inc. Tel: (213) 400-8078 13611 12th St., Suite-B, Chino, CA 91710 E-mail: moksud.rahman@gmail.com STRUCTURAL CALCULATIONS Project Name & Address Date: 19-May-21 by - Moksud Rahman, PE 1 4130 Cover St, Long Beach, CA 90808, USA PROPOSED GATE FOUNDATION         DESIGN BY:    JOSEPH BUONYA, A.I.A.    5932 Bolsa Avenue, Ste. #107 - Huntington Beach, CA 92649 Tel: (714) 892-8810 Fax: (800) 342-0507 www.asidvm.com     1334 N. SANTIAGO ST., SANTA ANA, CA 92701       ASCE Hazards Report Address: 1334 N Santiago St Santa Ana, California 92701 Standard:ASCE/SEI 7-22 Latitude:33.756939 Risk Category:II Longitude:-117.860318 Soil Class:Default Elevation:144.6745510797167 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph 300-year MRI 89 Vmph 700-year MRI 95 Vmph 1,700-year MRI 102 Vmph 3,000-year MRI 106 Vmph 10,000-year MRI 115 Vmph 100,000-year MRI 133 Vmph 1,000,000-year MRI 151 Vmph Data Source: ASCE/SEI 7-22, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Wed Mar 19 2025 Page 1 of 3https://ascehazardtool.org/Wed Mar 19 2025 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-22 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Values for 10-year MRI, 25-year MRI, 50-year MRI and 100-year MRI are Service Level wind speeds, all other wind speeds are Ultimate wind speeds. Site is not in a hurricane-prone region as defined in ASCE/SEI 7-22 Section 26.2. Page 2 of 3https://ascehazardtool.org/Wed Mar 19 2025 The ASCE Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE Hazard Tool. Page 3 of 3https://ascehazardtool.org/Wed Mar 19 2025 PROJECT : PAGE : CLIENT : DESIGN BY : JOB NO. : DATE : REVIEW BY : INPUT DATA Exposure category (B, C or D)=C Importance factor, pg 73, (0.87, 1.0 or 1.15)I =1.00 Category II Basic wind speed (3 sec. gust wind) V = 95 mph Topographic factor (Sec.6.5.7.2, pg 26 & 45)Kzt = 1 Flat Height of top h = 8 ft B = 10 ft Dimension of return corner Lr = 0 ft DESIGN SUMMARY Max horizontal wind pressure p = 26 psf Max total horizontal force at centroid of base F = 1.91 kips Max bending moment at centroid of base M = 8.39 ft-kips Max torsion at centroid of base T = 3.26 ft-kips ANALYSIS Velocity pressure qh = 0.00256 Kh Kzt Kd V2 I =16.69 psf where: qh = velocity pressure at mean roof height, h. (Eq. 6-15, page 27) Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 6-3, Case 1,pg 79)= 0.85 Kd = wind directionality factor. (Tab. 6-4, for building, page 80)= 0.85 h = height of top = 8.00 ft Wind Force Case A: resultant force though the geometric center (Sec. 6.5.14 & Fig. 6-20) p = qh G Cf ==20 psf F = p As =1.63 kips M = F (h - 0.5s) for sign, F (0.55h) for wall =7.18 ft-kips T ==0.00 ft-kips where: G = gust effect factor. (Sec. 6.5.8, page 26).= 0.85 Cf = net force coefficient. (Fig. 6-20, page 73)1.44 As = B s = 80.0 ft2 Wind Force Case B: resultant force at 0.2 B offset of the geometric center (Sec. 6.5.14 & Fig. 6-20) p = Case A =20 psf F = Case A =1.63 kips M = Case A =7.18 ft-kips T = 0.2 F B =3.26 ft-kips Wind Force Case C: resultant force different at each region (Sec. 6.5.14 & Fig. 6-20) p = qh G Cf F = S p As M = S [ F (h - 0.5s) for sign, F (0.55h) for wall ] T = S Ts s Distance Cf Pi Asi Fi Mi Ti 0 (ft) (Fig.6-20)2)(kips)(ft-kips)(ft-kips) 2.25 1 8.0 1.800 26 64 1.63 7.19 1.63 1.50 2 1.50 3 1.50 4 1.50 5 1.50 10 1.50 B 10.0 1.200 17 16 0.27 1.20 -1.09 S 1.91 8.39 0.54 <== Case C may not be considered, footnote 3 of Fig. 6-20 Moksudur Rahman GATE Wind Analysis for Freestanding Wall & Sign Based on ASCE 7-16 Pole Footing Embedded in Soil MS CONSULTING ENGINEERSLic. # : KW-06007915 DESCRIPTION:WIND LOAD, W=26 PSF X 8'X10'/2 = 1040 LB. ASSUMED 80% OPENING X 0.2=0.2 K Title Block Line 1 You can change this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 File: EC.ec6 Project Title: Engineer: Project ID: Printed: 9 FEB 2022, 6:49PM Project Descr: Code References Calculations per IBC 2018 1807.3, CBC 2019, ASCE 7-16 Load Combinations Used : ASCE 7-16 General Information Circular 18.0 250.0 1,500.0 No Lateral Restraint at Ground Surface Pole Footing Shape Pole Footing Diameter . . . . . . . . . . .in Allow Passive . . . . . . . . . . . . . . . . . . . . . .pcf Max Passive . . . . . . . . . . . . . . . . . . . . . .psf Calculate Min. Depth for Allowable Pressures +0.60WGoverning Load Combination : Lateral Load 0.120 Moment 0.960 k-ft Minimum Required Depth 3.0 ft k NO Ground Surface Restraint Pressures at 1/3 Depth Actual 247.075 psf Allowable 248.082 psf Controlling Values ft^2Footing Base Area 1.767 Maximum Soil Pressure 0.0 ksf k k k k k Applied Loads k Lateral Concentrated Load (k) D : Dead Load L : Live Lr : Roof Live S : Snow W : Wind E : Earthquake H : Lateral Earth Load distance above 0.20 8.0 k k k k k k k ft Lateral Distributed Loads (klf) TOP of Load above ground surface BOTTOM of Load above ground surface k/ft k/ft k/ft k/ft k/ft k/ft k/ft ftground surface ft Vertical Load (k) k Load Combination Results Factor Soil IncreaseForces @ Ground Surface Load Combination Required Loads - (k)Moments - (ft-k)Depth - (ft) Pressure at 1/3 Depth Allow - (psf)Actual - (psf) 0.00.000 0.000 0.13 1.0000.0 247.10.120 0.960+0.60W 3.00 1.000248.1 223.20.090 0.720+0.450W 2.75 1.000223.2 YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs 2 □ B � WIDTH �1 .. LENGTH 3400-6000G TANK ACCESS HATCH 2000G HINGED ROOF A TANK OPTIONS TANK SIZE LENGTH (IN) WIDTH (IN) HEIGHT (IN) 2000G 197 72 94 3400G 192 93 107 S000G 227 100 116 6000G 231 110 126 2 1 I HEIGHT _J .. 1 PROJECT REMOTE PLATINUM -WIDE, END DOOR DWG. EXTERNAL DIMENSIONS DWG.NO. DRAWN SD-PLT-REM-53 PA REV DATE 07/18/2023 SCALE SIZE SHEET 1:60 A 1 OF 2 1 B A REV 001 B A 2 ELECTRICAL PANEL 30/50 AMP ELECTRICAL DISCONNECT ELECTICAL CONTROL UNIT: •INVENTORY LEVEL GAUGE •OVERFILL ALARM & SILENCER•[LOW LEVEL WARNING LIGHT] [THERMOSTATIC HEATER] VENTED MANWAY LID 2" FNPT SPARE BULKHEAD LEVEL SENSOR [OVERFILL PREVENTION VALVE] [DEF ALTER] 2" FILL LINE DISPENSE LINE FOR FIELD CONNECTION •1" BALL VALVE•1" FNPT CONNECTION NOTE: OPTIONAL COMPONENTS ARE LISTED IN SQUARE BRACKETS [ ]. 2 2" DRY-BREAK FILL ADAPTER PROJECT DWG. DWG.NO. 1 30 PSI PRESSURE RELIEF VALVE AND ANTI-SIPHON VALVE FREESTANDING TANK SUBMERSIBLE PUMP REMOTE PLATINUM - WIDE, END DOOR PLUMBING & ELECTRICAL DRAWN REV 001 SD-PLT-REM-53 PA REV DATE 07/18/2023 SCALE SIZE SHEET 1:50 A 2OF2 1 B A 2 1 CITY OF SANTA ANA Planning and Building Agency w ► 72 �i *SIDE DOOR NOT AN OPTION ON 340OG-6000G UNITS 2 197 b I ull DEF SOLUTIONS bluel defsolutions.com AVAILABLE Approved FOR PERMIT ISSUANCE Master ID: Date: PROJECT REMOTE PLATINUM - WIDE, SIDE DOOR DWG. EXTERNAL DIMENSIONS DWG. NO. DRAWN REV DATE SD-PLT-REM-S4 ES 08/21/2023 SCALE SIZE SHEET 1:60 A 1 OF 1 REV 002 V IN w ICI 2 2" FNPT SPARE BULKHEAD LEVEL SENSOR --\ VENTED MANWAY LID [OVERFILL PREVENTION VALVE] ELECTRICAL PANEL ---\ 30/50 AMP ELECTRICAL DISCONNECT ELECTICAL CONTROL UNIT: • INVENTORY LEVEL GAUGE • OVERFILL ALARM & SILENCER • [LOW LEVEL WARNING LIGHT] [THERMOSTATIC HEATER] DISPENSE LINE FOR FIELD CONNECTION • 1" BALL VALVE • 1" FNPT CONNECTION NOTE: OPTIONAL COMPONENTS ARE LISTED IN SQUARE BRACKETS [ ]. 2 2" DRY -BREAK FILL ADAPTER b I ull DEF SOLUTIONS bluel defsolutions.com 1 CITY OF SANTA ANA Planning and Building Agency Approved FOR PERMIT ISSUANCE Master ID: Date: 30 PSI PRESSURE RELIEF VALVE AND ANTI -SIPHON VALVE FREESTANDING TANK SUBMERSIBLE PUMP [DEF FILTER] 2" FILL LINE PROJECT REMOTE PLATINUM - WIDE, SIDE DOOR DWG. REV PLUMBING & ELECTRICAL DWG. NO. DRAWN REV DATE 002 SD-PLT-REM-S4 ES 08/21/2023 SCALE SIZE SHEET 1:50 A 20F2 1 i V