HomeMy WebLinkAbout1227 W River Ln - PlanPAGE
REV: A1 9/17/2024
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
KIM HA NGUYEN
1227 W RIVER LN, SANTA ANA,
CA, 92706
PROJECT NUMBER:
SC1800916342
SHEET
DESIGNER:
FRENCE RETONE
CUSTOMER RESIDENCE:
TEL. (714) 675-1274
APN: 00113716
GILBERT CORREIA, C10, C46
CA CL #750184
(415) 580-6920 ex3
COVER SHEET
SCOPE OF WORK GENERAL NOTES
PV-1.0
VICINITY MAP
• SYSTEM SIZE: 5670W DC, 4200W AC
• MODULES: (14) JA SOLAR: JAM54S31-405/MR
• INVERTERS: (1) ABB: PVI-4.2-OUTD-S-US-A (240 V)
• RACKING: UR - SPEEDSEAL DECKFOOT TO FRAMING -
SNR-DC-00449
#SSTAMPCS
#ESTAMPCS
ABBREVIATIONS
A AMPERE
AC ALTERNATING CURRENT
AFC ARC FAULT CIRCUIT INTERUPTER
AZIM AZIMUTH
COMP COMPOSITION
DC DIRECT CURRENT
(E)EXISTING
ESS ENERGY STORAGE SYSTEM
MSP MAIN SERVICE PANEL
(N)NEW
PRE-FAB PRE-FABRICATED
PSF POUNDS PER SQUARE FOOT
PV PHOTOVOLTAIC
RSD RAPID SHUTDOWN DEVICE
TL TRANSFORMERLESS
V VOLTS
W WATTS
SHEET INDEX
PAGE #DESCRIPTION
PV-1.0 COVER SHEET
PV-2.0 SITE PLAN
PV-3.0 LAYOUT
PV-3.1 MOUNTING DETAIL
PV-4.0 ELECTRICAL
PV-4.1 ELECTRICAL CALCS
PV-5.0 SIGNAGE
PLANS DEPICT R&R FOR
MODULE REPLACEMENT AND RACKING REPLACEMENT
ONLY, NO OTHER WORK DONE.
• ALL WORK SHALL COMPLY WITH 2013 CRC/CBC/CEBC, 7-16 ASCE & 2013 NDS,
MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION
INSTRUCTIONS.
• PHOTOVOLTAIC SYSTEM IS FUNCTIONALLY GROUNDED. NO CONDUCTORS ARE
SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.41(A).
• MODULES CONFORM TO AND ARE LISTED UNDER UL 61730.
• INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
• RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.
• SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II
MODULES, ARE CLASS A FIRE RATED.
• RAPID SHUTDOWN SYSTEM IN COMPLIANCE WITH CEC 2022 690.12(B)(1) WHERE
CONDUCTORS OUTSIDE OF THE ARRAY ARE LIMITED TO LESS THAN 30V IN 30
SECONDS AND CEC 2022 690.12(B)(2)(2) WHERE CONDUCTORS INSIDE THE
ARRAY BOUNDARY IS LIMITED TO LESS THAN 80V IN 30 SECONDS
• CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(D).
• ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT.
• 13.87 AMPS MODULE SHORT CIRCUIT CURRENT.
• 21.68 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (A)(1) & 690.8 (B)].
Bldg# 101121965
Elec# 20184728
APPROVALS:
ELEC - MSmith
The scope of the plans is for the installation of the solar photovoltaic system only
and the approval is subject to compliance with all applicable city and state codes
and regulations regarding construction. The approval of the plans does not
constitute any certification of the accuracy, completeness, or building permit
status of the existing buildings and structures as shown.
/CE/
PL
PL
PL
PL
PL
PL
PL PL PL
PL
PL
PL
PL
PL
PL
PLPLPL
PAGE
REV: A1 9/17/2024
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
KIM HA NGUYEN
1227 W RIVER LN, SANTA ANA,
CA, 92706
PROJECT NUMBER:
SC1800916342
SHEET
DESIGNER:
FRENCE RETONE
CUSTOMER RESIDENCE:
TEL. (714) 675-1274
APN: 00113716
GILBERT CORREIA, C10, C46
CA CL #750184
(415) 580-6920 ex3
SITE PLAN
PV-2.0
#SSTAMPSP
#ESTAMPSP
SITE PLAN - SCALE = 1/16" = 1'-0"
ARRAY
PITCH
PV AREA
(SQFT)
AR-01 18°294.3
TRUE
AZIM
MAG
AZIM
168°180°
MAIN PANEL
INVERTER(S)
AC DISCONNECT(S)
DC DISCONNECT(S)
SUNRUN METER
DEDICATED PV METER
SERVICE ENTRANCE
INTERIOR EQUIPMENT
SHOWN AS DASHED
SE
MP
SM
PM
INV
AC
DC
SUB-PANELSP
CB IQ COMBINER BOX
1 COMMUNICATION
WIRES
PV LOAD CENTERLC
LEGEND
SCALE: NTS
NOTE: NOT ALL ITEMS IN LEGEND
WILL APPEAR IN SITE PLAN
PVC PIPE VENT
SATELLITE DISH
T-VENT
FIRE SETBACKS
METAL PIPE VENT
HARDSCAPE
PROPERTY LINEPL
ATTIC VENT
FLUSH ATTIC VENT
CHIMNEY
ALL EQUIPMENT IS
EXISTING
RECONFIGURED
EXISTING ARRAY
AR-01
RAIL
STANDOFFS &
FOOTINGS
SOLAR
MODULES
MP SESMINVAC
(E) RESIDENCE
(E) FENCE
W RIVER LN
(E) GATE
(E) POOL
(E) SKYLIGHT (TYP)
(E) DRIVEWAY
Exp. 12/31/2024
Signed On: 9/24/2024
/CE/
PAGE
REV: A1 9/17/2024
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
KIM HA NGUYEN
1227 W RIVER LN, SANTA ANA,
CA, 92706
PROJECT NUMBER:
SC1800916342
SHEET
DESIGNER:
FRENCE RETONE
CUSTOMER RESIDENCE:
TEL. (714) 675-1274
APN: 00113716
GILBERT CORREIA, C10, C46
CA CL #750184
(415) 580-6920 ex3
D1 - AR-01 - SCALE: 0.010389
AZIM:180°
PITCH: 18°
#SSTAMP
PV-3.0
LAYOUT
DESIGN CRITERIA
MAX DISTRIBUTED LOAD: 3 PSF
SNOW LOAD: 0 PSF
WIND SPEED:
96 MPH 3-SEC GUST.
S.S. LAG SCREW
5/16"x5.5": 2.5" MIN. EMBEDMENT
STRUCTURAL NOTES
SOLAR MODULE
SNAPNRACK
RACKING
4"
MODULE ELEVATION DETAIL - SCALE: NTS
ROOF INFO FRAMING INFO ATTACHMENT INFORMATION
Name Type Height Type Max
Span
OC
Spacing Detail Max Landscape
OC Spacing
Max Landscape
Overhang
Max Portrait
OC Spacing
Max Portrait
Overhang Configuration
AR-01 SPEEDSEAL
DECKFOOT 1-Story 2X6 RAFTERS 7'-9"24"UR - SPEEDSEAL DECKFOOT TO FRAMING -
SNR-DC-00449 6'-0"2'-4"6'-0" 2'-3"STACKED
INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION.
* IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" BOUNDARY REGION OF ANY ROOF PLANE EDGES (EXCEPT VALLEYS), THEN ATTACHMENTS
NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS:
** ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50%.
** ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS.
(E) SKYLIGHT (TYP)
FRAMING CHANGE6' TYP
34'-3"
9'-4"
3'-9"
30'-2"
4'-10"9'-3"
7'-6"
1'-6"
14'-5"
4'-4"
Exp. 12/31/2024
Signed On: 9/24/2024
/CE/
PAGE
REV: A1 9/17/2024
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
KIM HA NGUYEN
1227 W RIVER LN, SANTA ANA,
CA, 92706
PROJECT NUMBER:
SC1800916342
SHEET
DESIGNER:
FRENCE RETONE
CUSTOMER RESIDENCE:
TEL. (714) 675-1274
APN: 00113716
GILBERT CORREIA, C10, C46
CA CL #750184
(415) 580-6920 ex3
MOUNTING DETAIL
PV-3.1
BIN:
TOP
N/A REVISION:
1 1/13/2021 NEW DETAIL
2 4/5/2021 2PC CLAMP
MJA
MJA
INSTALLATION OVERVIEW
Solar Mounting Solutions
SNAPNRACK UR SPEEDSEAL DECKFOOT FOR COMPOSITION
ROOF MOUNTING ONTO WOOD RAFTER
REFER TO SNAPNRACK ENGINEERING CHARTS FOR APPLICABLE
RAIL SPANS. "BIN" NUMBER ON CHART SHOULD MATCH "BIN"
NUMBER ON THIS DRAWING
(X2) #14 FULLY THREADED WOOD SCREWS, S.S. MUST
PENETRATE A MIN. OF 11 2" INTO STRUCTURAL MEMBER. (X2)
#14 FULLY THREADED WOOD SCREWS, S.S. MUST EMBED
FULLY INTO WOOD DECK
REFER TO SNAPNRACK INSTALLATION MANUAL FOR 5 16"Ø
HARDWARE TORQUE SPECIFICATIONS
SNAPNRACK SPEEDSEAL DECKFOOT CAN MOUNT IN ANY
ORIENTATION ON THE ROOF
RAIL CAN MOUNT ON BOTH SIDES OF SPEEDSEAL DECKFOOT
FOR ADDITIONAL LEVELING DETAILS, REFER TO SNAPNRACK
DETAIL DRAWING "SNR-DC-00447 ULTRA RAIL, COMPONENT
DETAIL, ULTRA RAIL LEVELING SPACER"
B 8/2/2021 DC000595 MJA
3 6/13/2024 REMOVE MIN DECK THICKNESS KMA
3.860
2.080
ROOF DECKING
STRUCTURAL MEMBER
(RAFTER)
COMP SHINGLE
ROOFING, TYP.
(X2) #14 FULLY THREADED
WOOD SCREW S.S. MUST EMBED
FULLY INTO WOOD DECK
(X2) #14 FULLY THREADED
WOOD SCREW S.S. INTO
STRUCTURAL MEMBER.
SIZE LENGTH APPROPRIATELY
ATTACHMENT DETAIL
MINIMUM RAFTER
PENETRATION:
11 2"
MODULE HEIGHT MAX:
UR-40 = 43 8"
UR-60 = 5"SCREW HEIGHT
OFF ROOF:
9 16"
SNAPNRACK, ULTRA RAIL
COMP SHINGLE ROOFING, TYP.
ROOF DECKING
WOOD RAFTER, TYP.
(STRUCTURAL MEMBER)
EXPLODED
5 16" Ø-18 X 13 4" BOLT,
SERRATED FLANGE, S.S.
COIL SPRING FOR 3 8" Ø
BOLT, S.S. (OPTIONAL)
SNAPNRACK, SPEEDSEAL
DECKFOOT BASE, SEALING
SNAPNRACK, UR
MOUNT THRU
SNAPNRACK, UR
MOUNT TAPPED
UR-40 RAIL | UR-60 RAIL
FOR USE WITH SNAPNRACK ULTRA SERIES RAILS
15 8"
11 2"
11 2"
21 4"
SCALE:
DATE:
NTS
6/13/2024
DRAWING NUMBER:
SNR-DC-00449
REV:
3
Sunrun South LLC
595 MARKET STREET, 29TH FLOOR SAN FRANCISCO, CA 94105 USA
PHONE (415) 580-6900 FAX (415) 580-6902
THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY
REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE
WRITTEN CONSENT OF SUNRUN SOUTH LLC.
DESCRIPTION:
ULTRA RAIL, ATTACHMENT DETAIL, UR
SPEEDSEAL DECKFOOT TO RAFTER
Exp. 12/31/2024
Signed On:
9/24/2024
PAGE
REV: A1 9/17/2024
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
KIM HA NGUYEN
1227 W RIVER LN, SANTA ANA,
CA, 92706
PROJECT NUMBER:
SC1800916342
SHEET
DESIGNER:
FRENCE RETONE
CUSTOMER RESIDENCE:
TEL. (714) 675-1274
APN: 00113716
GILBERT CORREIA, C10, C46
CA CL #750184
(415) 580-6920 ex3
M
240V METER SOCKET
125A CONTINUOUS &
240V METER
200A, FORM 2S
(E) SUN RUN
CENTRON 4G
METER
EXISTING
200A MAIN
BREAKER
(END FED)
FACILITY
GROUND(E) 25A
PV BREAKER AT
OPPOSITE END
OF BUSBAR
M
METER #:
SCE 222013-154795
120/240 VAC
SINGLE PHASE
SERVICE
UTILITY
GRID
EXISTING 200A
MAIN PANEL
FACILITY
LOADS
200 A
MAIN BUS
(E) LOCKABLE
BLADE TYPE
AC DISCONNECT
SQUARE D
3R, 30A,2P
120/240VAC
3 3 3
1
2 JUNCTION BOX
OR EQUIVALENT
ABB: PVI-4.2-OUTD-S-US-A
(240 V)
4200 WATT INVERTER
LOAD RATED DC
DISCONNECT WITH AFCI
PV MODULES
JA SOLAR: JAM54S31-405/MR
(7) MODULES
(1) STRING OF (7) MODULES
PV MODULES
JA SOLAR: JAM54S31-405/MR
(7) MODULES
(1) STRING OF (7) MODULES
CONDUIT SCHEDULE
#CONDUIT CONDUCTOR NEUTRAL GROUND
1 NONE (4) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER
2 3/4" EMT OR EQUIV.(4) 10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2
3 EXISTING EXISTING EXISTING EXISTING
PV-4.0
ELECTRICAL
#ESTAMP
GENERAL NOTES:
• CITY REQUIRES TWO SOURCES OF GROUND - UFER, TWO GROUNDS RODS OR
COLD WATER GAS BOND
• 260.61 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE.
SYSTEM CHARACTERISTICS - INVERTER 1
SYSTEM SIZE:
SYSTEM OPEN CIRCUIT VOLTAGE:
SYSTEM OPERATING VOLTAGE:
MAX ALLOWABLE DC VOLTAGE:
SYSTEM OPERATING CURRENT:
SYSTEM SHORT CIRCUIT CURRENT:
5670 W
280.32 V
218.47 V
600 V
25.96 A
34.68 A
MODULE CHARACTERISTICS
JA SOLAR: JAM54S31-405/MR:
OPEN CIRCUIT VOLTAGE:
MAX POWER VOLTAGE:
SHORT CIRCUIT CURRENT:
405 W
37.23 V
31.21 V
13.87 A
PAGE
REV: A1 9/17/2024
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
KIM HA NGUYEN
1227 W RIVER LN, SANTA ANA,
CA, 92706
PROJECT NUMBER:
SC1800916342
SHEET
DESIGNER:
FRENCE RETONE
CUSTOMER RESIDENCE:
TEL. (714) 675-1274
APN: 00113716
GILBERT CORREIA, C10, C46
CA CL #750184
(415) 580-6920 ex3
PV-4.1
ELECTRICAL CALCS
#ESTAMP
System Information
5.265 kW DC Photovoltaic System
(13) JA Solar: JAM54S31-405/MR, ABB:
PVI-4.2-OUTD-S-US-A (240 V)
Allowable Backfeed
Allowable Backfeed = (Main Panel Rating) x 1.2 - (Main
Breaker Rating) =
200A x 1.2 - 200A = 40A
25A ≤ 40A → Interconnection meets 705.12(D)(2)
requirements.
Inverter Overcurrent Protection
(Inverter Max Current) x (Continuous Load) =
20 A x 1.25 = 25 A → 25 A Overcurrent Protection
Per Manufacturer
DC Wire Sizing
Max Circuit Current = (Module Isc) x (High
Irradiance)[690.8(A)(1)] x (Continuous
Load)[690.8(B)(1)]=
13.87A x 1.56 = 21.64A
Adjusted Conductor Ampacity = (High Temp)[Table
310.15(B)(2)(a)] x (Conduit Fill)[Table 310.15(B)(3)(a)] x
(Conductor Ampacity)[Table 310.15(B)(16)] =
0.91 x 0.8 x 40A = 29.12A
Terminal Rating[110.14(C)] =
10 AWG, 75°C Rated = 35A
29.12A < 35A → Adjusted conductor ampacity governs
conductor sizing.
21.64A < 29.12A → 10 AWG Ampacity OK
Therefore 10 AWG is sufficient.
AC Wire Sizing
Max AC Output Current = (Max Inverter Output) x
(Continuous Load)[210.19(A)(1)] =
20 A x 1.25 = 25 A
Adjusted Conductor Ampacity = (High Temp)[Table
310.15(B)(2)(a)] x (Conduit Fill)[Table 310.15(B)(3)(a)] x
(Conductor Ampacity)[Table 310.15(B)(16)] =
0.91 x 1 x 40A = 36.4A
Terminal Rating[110.14(C)] =
10 AWG, 75°C Rated = 35A
35A < 36.4A → Terminal rating governs conductor
sizing.
25A < 35A → 10 AWG Ampacity OK
Therefore 10 AWG is sufficient.
System Characteristics
Operating Voltage = (Module VMP) x (# Modules /
String) =
31.21 V x 7 = 218.47 V
Max Open Circuit Voltage = {[((Temp Coef VOC) x
(VOC)) / 100] x [Low Temp - STC Temp] + VOC} x (#
Modules / String) =
{[(-0.28 %/°C x 37.23 V) / 100] x [-2 °C - 25 °C] +
37.23 V} x 7 = 280.32 V
Operating Current = (Module IMP) * (# Strings) =
12.98 A x 2 = 25.96A
Short Circuit Current = 1.25 x (Module Isc) x (# Strings)
1.25 x 13.87 A x 2 = 34.68A
PAGE
REV: A1 9/17/2024
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
KIM HA NGUYEN
1227 W RIVER LN, SANTA ANA,
CA, 92706
PROJECT NUMBER:
SC1800916342
SHEET
DESIGNER:
FRENCE RETONE
CUSTOMER RESIDENCE:
TEL. (714) 675-1274
APN: 00113716
GILBERT CORREIA, C10, C46
CA CL #750184
(415) 580-6920 ex3
SIGNAGE
PV-5.0
#ESTAMP
NOTES AND SPECIFICATIONS:
·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE 2013 CEC ARTICLE
110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR
IF REQUESTED BY THE LOCAL AHJ.
·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
WORDS, COLORS AND SYMBOLS.
·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING
METHOD AND SHALL NOT BE HAND WRITTEN.
·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
INVOLVED.
·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY
SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.
·DO NOT COVER EXISTING MANUFACTURER LABELS.
WARNING!
SOURCES: UTILITY GRID
AND PV SOLAR ELECTRIC
SYSTEM
DUAL POWER SUPPLY
LABEL LOCATION:
UTILITY SERVICE METER AND MAIN
SERVICE PANEL.
PER CODE(S): CEC 2016: 705.12(D)(3),
NEC 2014: 705.12(D)(3), NEC 2011:
705.12(D)(4)
WARNING: PHOTOVOLTAIC
POWER SOURCE
WARNING: PHOTOVOLTAIC
POWER SOURCE
LABEL LOCATION:
INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
AT EACH TURN, ABOVE AND BELOW PENETRATIONS,
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
PER CODE(S): CEC 2016: 690.31(G)(3), 690.31(G)(4), NEC
2014: 690.31(G)(3), 690.31(G)(4), NEC 2011: 690.31(E)(3),
690.31(E)(4), IFC 2012: 605.11.1.4
PHOTOVOLTAIC SYSTEM
EQUIPPED WITH
RAPID SHUTDOWN
LABEL LOCATION:
UTILITY SERVICE ENTRANCE/METER, INVERTER/DC
DISCONNECT IF REQUIRED BY LOCAL AHJ, OR
OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ.
PER CODE(S): CEC 2016: 690.12, NEC 2014: 690.12, IFC
2012: 605.11.1
PHOTOVOLTAIC DC DISCONNECT
RATED MAXIMUM POWER-POINT CURRENT:
RATED MAXIMUM POWER-POINT VOLTAGE:
MAXIMUM SYSTEM VOLTAGE:
MAXIMUM SHORT CIRCUIT CURRENT:
ADC
VDC
VDC
ADC
25.96
218.47
280.32
34.68
LABEL LOCATION:
INVERTER(S), DC DISCONNECT(S).
PER CODE(S): CEC 2016: 690.53, NEC 2014: 690.53, NEC
2011: 690.53
INVERTER 1
ELECTRICAL SHOCK HAZARD
DO NOT TOUCH TERMINALS.
TERMINALS ON LINE AND LOAD
SIDES MAY BE ENERGIZED IN
THE OPEN POSITION
WARNING!
LABEL LOCATION:
INVERTER(S), AC/DC DISCONNECT(S),
AC COMBINER PANEL (IF APPLICABLE).
PER CODE(S): CEC 2016: 690.17(E), NEC
2014: 690.17(E), NEC 2011: 690.17(4)
LABEL LOCATION:
INSTALLED WITHIN 3' OF RAPID SHUT DOWN SWITCH
PER CODE(S): CEC 2016: 690.12, NEC 2014: 690.12,
NEC 690.56, IFC 2012: 605.11.1
RAPID SHUTDOWN SWITCH
FOR SOLAR PV SYSTEM
THE DC CONDUCTORS OF THIS
PHOTOVOLTAIC SYSTEM ARE
UNGROUNDED AND MAY BE
ENERGIZED
ELECTRICAL SHOCK HAZARD
WARNING!
LABEL LOCATION:
INVERTER(S), DC DISCONNECTS.
PER CODE(S): CEC 2016: 690.35(F), NEC
2014: 690.35(F), NEC 2011: 690.35(F)
!
DO NOT ADD LOADS
PHOTOVOLTAIC SYSTEM
COMBINER PANEL
WARNING
LABEL LOCATION:
PHOTOVOLTAIC AC COMBINER (IF
APPLICABLE).
PER CODE(S): CEC 2016:
705.12(D)(2)(3)(c), NEC 2014:
705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4)
MAXIMUM AC OPERATING CURRENT:
NOMINAL OPERATING AC VOLTAGE:
20 AMPS
240 VAC
PHOTOVOLTAIC AC DISCONNECT
LABEL LOCATION:
AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION.
PER CODE(S): CEC 2016: 690.54, NEC 2014: 690.54, NEC
2011: 690.54
WARNING!
DO NOT RELOCATE THIS
OVERCURRENT DEVICE
POWER SOURCE OUTPUT CONNECTION
LABEL LOCATION:
ADJACENT TO PV BREAKER (IF
APPLICABLE).
PER CODE(S): CEC 2016:
705.12(D)(2)(3)(b), NEC 2014:
705.12(D)(2)(3)(b), NEC 2011: 705.12(D)(7)
POWER TO THIS BUILDING IS
ALSO SUPPLIED FROM THE
FOLLOWING SOURCES WITH
DISCONNECTS AS SHOWN
CAUTION:
1227 W RIVER LN, SANTA ANA, CA, 92706
SOLAR PANELS ON ROOF
SERVICE ENTRANCE AND PV
BREAKER DISCONNECT
AC DISCONNECT
SUNRUN METER
INVERTER (EXT)
RAPID SHUTDOWN SWITCH
Docusign Envelope ID: A0157799-6800-43FA-9FBC-953EDA0092A9
1227 W RIVER
LN, SANTA ANA
CA 92706
714-675-1274evewin2001@gmail.com
12/6/2024
Khiem Nguyen
r
rf O P CAII.OA001A
C:l C:
DIE PAPrWPV Or CONSUftlA A/rA,tr.
CONTRACTORS
STATE LICENSE BOARD
License Number
765730
ACTIVE LICENSE
I
OW
tft, INDIV
CITY OF SANTA ANA
Planning and Building Agency
Approved
FOR PERMIT ISSUANfm6
Business Name JASON POCH DBA SUNCORE SOLAR
Classirficatlon(s) C 10
f xpiratlon Uatr 07/31/2025
www cslb ca gov
SAA ANA
nd Building Agency
aF
:3
n
-proved
C
=
MIT ISSUANCE
O
co
D
_
eD
T
a
n
O
m
-'
3
:3
c
o
m
ul
a
�,
D
ro
�
�}
�
a
C
0
_
�.
a
r+
Q
x
O'
Z-m
C
j
�D
a)
n (OJ1
0
<
-
ul
r-0
O
a
CD
o
�,
a
a
a
�,
cv
3
Cy
N
N'Cc
_
Cl
�
C
O
3
r_
v
Lo
<
C
to
(D
?
fD ^
rD
O
Q
�
�..L
^
(D
na,�
v
x
°
o
D
O
O
'
_
(D
x
a
C
<
OD
C
O
:3C
O
w
m
a
?
o
-.
O
cQ
?
('D
o
�
�
a
n�
J
—C—tTY OF SANTA ANA-
Planning and Building Age cy
Approved
FOR PERMIT ISSUANCE
Mas
*Suncore Solar
License 4765730
l Jason Poch, authorize Jaxon Wright to pull city business license and permits on my behalf
under our contractors license.
Ca License #765730
Thank you
J on P,�\
Suncore Solar
Please See Attached
Form For Notary
Dated: J U
Planning and Builditg Agency
ACKNOWLEDGMENT
A notary public or other officer completing this
certificate verifies only the identity of the individual
who signed the document to which this certificate is
attached, and not the truthfulness, accuracy, or
validi of that document
State of California
County of ORANGE )
Approvd
FOR PERMIT IS ANCE
Master ID:
Date:
On June 21 2W "I before me, Darby Payne Hawke Driskill Notary Public
(insert name and title of the officer)
personally appeared Jason rG N
who proved to me on the basis of satisfactory evidence to be the person(Kwhose name( is/are
subscribed to the within instrument and acknowledged to me that he/sw/tha9 executed the same in
hislkr¢r/tKeir authorized capacity(ios), and that by his/h6r/their signature(spron the instrument the
person(py, or the entity upon behalf of which the person(sr) acted, executed the instrument
I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing
paragraph is true and correct
WITNESS my hand and
Signature
....................................
), DARBY PAYNE
k1b HAWKE DRISKILL
seal. COMM a 2382150 x
ORANGE County
VCanforma Notary Public
Comm Exp Nov. 7. 2025
(Seal) ............................
To Whom It May Concern:
I am writing to confirm that I, ___________________, am aware that Suncore solar has been
contacted to perform the installation of new equipment on my home located at
___________________________________________.
Additionally, this letter acknowledges that if any other company has submitted a permit for this
work, this serves as my authorization to void that permit on my behalf, as Suncore Solar is the
company I have contracted for this project.
Should you have any questions or require further documentation, please feel free to contact me
directly at ______________________ or _________________________.
Thank you for your attention to this matter.
Sincerely,
________________________________________________________
Name
________________________________________________________
Date
Docusign Envelope ID: 71303D2C-EE19-43AF-A645-787E7486BFA6
Khiem and Kim Ha Nguyen
evewin2001@gmail.com(714) 675-1274
3/18/2025
1227 W River Ln Santa Ana, CA 92706
To Whom It May Concern:
I am writing to confirm that I, ___________________, am aware that Suncore solar has been
contacted to perform the installation of new equipment on my home located at
___________________________________________.
Additionally, this letter acknowledges that if any other company has submitted a permit for this
work, this serves as my authorization to void that permit on my behalf, as Suncore Solar is the
company I have contracted for this project.
Should you have any questions or require further documentation, please feel free to contact me
directly at ______________________ or _________________________.
Thank you for your attention to this matter.
Sincerely,
________________________________________________________
Name
________________________________________________________
Date
Docusign Envelope ID: 71303D2C-EE19-43AF-A645-787E7486BFA6
Khiem and Kim Ha Nguyen
evewin2001@gmail.com(714) 675-1274
3/18/2025
1227 W River Ln Santa Ana, CA 92706
Rev: 7/15/2021
RESIDENTIAL
PHOTOVOLTAIC
CHECKLIST
SOL-01 CBC 2019
Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only
Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and
sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of
minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required.
Project Address:
Contractor Company Name:
Contractor License Number:
YES NO Are the following applicable to the proposed project?
1. Will the PV system layout provide the required three-foot wide clear access pathways
per Section 605.11 of the California Fire Code, and is this shown on the roof plan?
2. Will the PV system be installed on a roof having only one roofing layer with no
overlays?
3. Will the PV array be flush mounted to the existing roof so that the plane of the
modules (panels) are parallel to the plane of the roof?
4. Will the PV system weigh maximum 4 pounds per square feet or less?
5. Will the PV system be installed where the modules do not overhang any roof edges
(such as eaves, gabled ends, ridges and hips)?
6. Will the PV system be installed with a space of 2” minimum to 10” maximum between
the underside of modules and the surface of the roof?
7. Will the PV system be installed without using any ballast system or counter-weight
system?
8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet
and is this maximum horizontal spacing shown on the plans?
9. Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch
embedment into roof rafters (with pre-drilled holes) and is this minimum embedment
shown on the plans?
10. Are ALL the structural pages of the plans stamped and signed by a California
licensed professional engineer? (including project specific site plan, PV layout,
anchorage spacing, anchorage details and manufacturer’s PV support information.)
I certify under penalty of perjury under the laws of the State of California that the above is true:
Print Name: Signature:
Phone Number: Date:
Email Address:
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
Certificate Of Completion
Envelope Id: A0157799-6800-43FA-9FBC-953EDA0092A9 Status: Completed
Subject: Complete with Docusign: Customer Letter.pdf
Source Envelope:
Document Pages: 1 Signatures: 1 Envelope Originator:
Certificate Pages: 3 Initials: 0 Jaxson Wright
AutoNav: Enabled
EnvelopeId Stamping: Enabled
Time Zone: (UTC-08:00) Pacific Time (US & Canada)
permits.suncore@Gmail.com
IP Address: 69.129.120.22
Record Tracking
Status: Original
12/5/2024 6:55:11 AM
Holder: Jaxson Wright
permits.suncore@Gmail.com
Location: DocuSign
Signer Events Signature Timestamp
Khiem Nguyen
evewin2001@gmail.com
Security Level: Email, Account Authentication
(None)
Signature Adoption: Pre-selected Style
Using IP Address: 172.58.113.106
Sent: 12/5/2024 6:56:15 AM
Viewed: 12/6/2024 5:24:45 PM
Signed: 12/6/2024 5:25:53 PM
Electronic Record and Signature Disclosure:
Accepted: 12/6/2024 5:24:45 PM
ID: b580cbd9-7440-4ef0-b8d4-9eed84d562a1
In Person Signer Events Signature Timestamp
Editor Delivery Events Status Timestamp
Agent Delivery Events Status Timestamp
Intermediary Delivery Events Status Timestamp
Certified Delivery Events Status Timestamp
Carbon Copy Events Status Timestamp
Witness Events Signature Timestamp
Notary Events Signature Timestamp
Envelope Summary Events Status Timestamps
Envelope Sent Hashed/Encrypted 12/5/2024 6:56:15 AM
Certified Delivered Security Checked 12/6/2024 5:24:45 PM
Signing Complete Security Checked 12/6/2024 5:25:53 PM
Completed Security Checked 12/6/2024 5:25:53 PM
Payment Events Status Timestamps
Electronic Record and Signature Disclosure
ELECTRONIC RECORD AND SIGNATURE DISCLOSURE
From time to time, Jaxson Wright (we, us or Company) may be required by law to provide to you certain written notices
or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures
electronically through the DocuSign system. Please read the information below carefully and thoroughly, and if you can
access this information electronically to your satisfaction and agree to this Electronic Record and Signature Disclosure
(ERSD), please confirm your agreement by selecting the check-box next to ‘I agree to use electronic records and
signatures’ before clicking ‘CONTINUE’ within the DocuSign system.
Getting paper copies
At any time, you may request from us a paper copy of any record provided or made available electronically to you by us.
You will have the ability to download and print documents we send to you through the DocuSign system during and
immediately after the signing session and, if you elect to create a DocuSign account, you may access the documents for a
limited period of time (usually 30 days) after such documents are first sent to you. After such time, if you wish for us to
send you paper copies of any such documents from our office to you, you will be charged a $0.00 per-page fee. You may
request delivery of such paper copies from us by following the procedure described below.
Withdrawing your consent
If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us
that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your
decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and
disclosures electronically is described below.
Consequences of changing your mind
If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can
complete certain steps in transactions with you and delivering services to you because we will need first to send the
required notices or disclosures to you in paper format, and then wait until we receive back from you your
acknowledgment of your receipt of such paper notices or disclosures. Further, you will no longer be able to use the
DocuSign system to receive required notices and consents electronically from us or to sign electronically documents from
us.
All notices and disclosures will be sent to you electronically
Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you
through the DocuSign system all required notices, disclosures, authorizations, acknowledgements, and other documents
that are required to be provided or made available to you during the course of our relationship with you. To reduce the
chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and
disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the
disclosures and notices electronically or in paper format through the paper mail delivery system. If you do not agree with
this process, please let us know as described below. Please also see the paragraph immediately above that describes the
consequences of your electing not to receive delivery of the notices and disclosures electronically from us.
How to contact Jaxson Wright:
You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies
of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as
follows: To contact us by email send messages to: permits.suncore@Gmail.com
To advise Jaxson Wright of your new email address
To let us know of a change in your email address where we should send notices and disclosures electronically to you, you
must send an email message to us at permits.suncore@Gmail.com and in the body of such request you must state: your
Electronic Record and Signature Disclosure created on: 11/26/2024 2:42:50 PM
Parties agreed to: Khiem Nguyen
previous email address, your new email address. We do not require any other information from you to change your email
address
If you created a DocuSign account, you may update it with your new email address through your account preferences.
To request paper copies from Jaxson Wright
To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically,
you must send us an email to permits.suncore@Gmail.com and in the body of such request you must state your email
address, full name, mailing address, and telephone number. We will bill you for any fees at that time, if any.
To withdraw your consent with Jaxson Wright
To inform us that you no longer wish to receive future notices and disclosures in electronic format you may:
i. decline to sign a document from within your signing session, and on the subsequent page, select the check-box
indicating you wish to withdraw your consent, or you may;
ii. send us an email to permits.suncore@Gmail.com and in the body of such request you must state your email, full name,
mailing address, and telephone number. We do not need any other information from you to withdraw consent. The
consequences of your withdrawing consent for online documents will be that transactions may take a longer time to
process.
Required hardware and software
The minimum system requirements for using the DocuSign system may change over time. The current system
requirements are found here: https://support.docusign.com/guides/signer-guide-signing-system-requirements.
Acknowledging your access and consent to receive and sign documents electronically
To confirm to us that you can access this information electronically, which will be similar to other electronic notices and
disclosures that we will provide to you, please confirm that you have read this ERSD, and (i) that you are able to print on
paper or electronically save this ERSD for your future reference and access; or (ii) that you are able to email this ERSD to
an email address where you will be able to print on paper or save it for your future reference and access. Further, if you
consent to receiving notices and disclosures exclusively in electronic format as described herein, then select the check-
box next to ‘I agree to use electronic records and signatures’ before clicking ‘CONTINUE’ within the DocuSign system.
By selecting the check-box next to ‘I agree to use electronic records and signatures’, you confirm that:
You can access and read this Electronic Record and Signature Disclosure; and
You can print on paper this Electronic Record and Signature Disclosure, or save or send this Electronic Record and
Disclosure to a location where you can print it, for future reference and access; and
Until or unless you notify Jaxson Wright as described above, you consent to receive exclusively through electronic
means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be
provided or made available to you by Jaxson Wright during the course of your relationship with Jaxson Wright.