Loading...
HomeMy WebLinkAbout1227 W River Ln - PlanPAGE REV: A1 9/17/2024 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 KIM HA NGUYEN 1227 W RIVER LN, SANTA ANA, CA, 92706 PROJECT NUMBER: SC1800916342 SHEET DESIGNER: FRENCE RETONE CUSTOMER RESIDENCE: TEL. (714) 675-1274 APN: 00113716 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 COVER SHEET SCOPE OF WORK GENERAL NOTES PV-1.0 VICINITY MAP • SYSTEM SIZE: 5670W DC, 4200W AC • MODULES: (14) JA SOLAR: JAM54S31-405/MR • INVERTERS: (1) ABB: PVI-4.2-OUTD-S-US-A (240 V) • RACKING: UR - SPEEDSEAL DECKFOOT TO FRAMING - SNR-DC-00449 #SSTAMPCS #ESTAMPCS ABBREVIATIONS A AMPERE AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT (E)EXISTING ESS ENERGY STORAGE SYSTEM MSP MAIN SERVICE PANEL (N)NEW PRE-FAB PRE-FABRICATED PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS V VOLTS W WATTS SHEET INDEX PAGE #DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-3.0 LAYOUT PV-3.1 MOUNTING DETAIL PV-4.0 ELECTRICAL PV-4.1 ELECTRICAL CALCS PV-5.0 SIGNAGE PLANS DEPICT R&R FOR MODULE REPLACEMENT AND RACKING REPLACEMENT ONLY, NO OTHER WORK DONE. • ALL WORK SHALL COMPLY WITH 2013 CRC/CBC/CEBC, 7-16 ASCE & 2013 NDS, MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. • PHOTOVOLTAIC SYSTEM IS FUNCTIONALLY GROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.41(A). • MODULES CONFORM TO AND ARE LISTED UNDER UL 61730. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED. • RAPID SHUTDOWN SYSTEM IN COMPLIANCE WITH CEC 2022 690.12(B)(1) WHERE CONDUCTORS OUTSIDE OF THE ARRAY ARE LIMITED TO LESS THAN 30V IN 30 SECONDS AND CEC 2022 690.12(B)(2)(2) WHERE CONDUCTORS INSIDE THE ARRAY BOUNDARY IS LIMITED TO LESS THAN 80V IN 30 SECONDS • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(D). • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 13.87 AMPS MODULE SHORT CIRCUIT CURRENT. • 21.68 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (A)(1) & 690.8 (B)]. Bldg# 101121965 Elec# 20184728 APPROVALS: ELEC - MSmith The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. /CE/ PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PLPLPL PAGE REV: A1 9/17/2024 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 KIM HA NGUYEN 1227 W RIVER LN, SANTA ANA, CA, 92706 PROJECT NUMBER: SC1800916342 SHEET DESIGNER: FRENCE RETONE CUSTOMER RESIDENCE: TEL. (714) 675-1274 APN: 00113716 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 SITE PLAN PV-2.0 #SSTAMPSP #ESTAMPSP SITE PLAN - SCALE = 1/16" = 1'-0" ARRAY PITCH PV AREA (SQFT) AR-01 18°294.3 TRUE AZIM MAG AZIM 168°180° MAIN PANEL INVERTER(S) AC DISCONNECT(S) DC DISCONNECT(S) SUNRUN METER DEDICATED PV METER SERVICE ENTRANCE INTERIOR EQUIPMENT SHOWN AS DASHED SE MP SM PM INV AC DC SUB-PANELSP CB IQ COMBINER BOX 1 COMMUNICATION WIRES PV LOAD CENTERLC LEGEND SCALE: NTS NOTE: NOT ALL ITEMS IN LEGEND WILL APPEAR IN SITE PLAN PVC PIPE VENT SATELLITE DISH T-VENT FIRE SETBACKS METAL PIPE VENT HARDSCAPE PROPERTY LINEPL ATTIC VENT FLUSH ATTIC VENT CHIMNEY ALL EQUIPMENT IS EXISTING RECONFIGURED EXISTING ARRAY AR-01 RAIL STANDOFFS & FOOTINGS SOLAR MODULES MP SESMINVAC (E) RESIDENCE (E) FENCE W RIVER LN (E) GATE (E) POOL (E) SKYLIGHT (TYP) (E) DRIVEWAY Exp. 12/31/2024 Signed On: 9/24/2024 /CE/ PAGE REV: A1 9/17/2024 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 KIM HA NGUYEN 1227 W RIVER LN, SANTA ANA, CA, 92706 PROJECT NUMBER: SC1800916342 SHEET DESIGNER: FRENCE RETONE CUSTOMER RESIDENCE: TEL. (714) 675-1274 APN: 00113716 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 D1 - AR-01 - SCALE: 0.010389 AZIM:180° PITCH: 18° #SSTAMP PV-3.0 LAYOUT DESIGN CRITERIA MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF WIND SPEED: 96 MPH 3-SEC GUST. S.S. LAG SCREW 5/16"x5.5": 2.5" MIN. EMBEDMENT STRUCTURAL NOTES SOLAR MODULE SNAPNRACK RACKING 4" MODULE ELEVATION DETAIL - SCALE: NTS ROOF INFO FRAMING INFO ATTACHMENT INFORMATION Name Type Height Type Max Span OC Spacing Detail Max Landscape OC Spacing Max Landscape Overhang Max Portrait OC Spacing Max Portrait Overhang Configuration AR-01 SPEEDSEAL DECKFOOT 1-Story 2X6 RAFTERS 7'-9"24"UR - SPEEDSEAL DECKFOOT TO FRAMING - SNR-DC-00449 6'-0"2'-4"6'-0" 2'-3"STACKED INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. * IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" BOUNDARY REGION OF ANY ROOF PLANE EDGES (EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: ** ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50%. ** ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS. (E) SKYLIGHT (TYP) FRAMING CHANGE6' TYP 34'-3" 9'-4" 3'-9" 30'-2" 4'-10"9'-3" 7'-6" 1'-6" 14'-5" 4'-4" Exp. 12/31/2024 Signed On: 9/24/2024 /CE/ PAGE REV: A1 9/17/2024 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 KIM HA NGUYEN 1227 W RIVER LN, SANTA ANA, CA, 92706 PROJECT NUMBER: SC1800916342 SHEET DESIGNER: FRENCE RETONE CUSTOMER RESIDENCE: TEL. (714) 675-1274 APN: 00113716 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 MOUNTING DETAIL PV-3.1 BIN: TOP N/A REVISION: 1 1/13/2021 NEW DETAIL 2 4/5/2021 2PC CLAMP MJA MJA INSTALLATION OVERVIEW Solar Mounting Solutions SNAPNRACK UR SPEEDSEAL DECKFOOT FOR COMPOSITION ROOF MOUNTING ONTO WOOD RAFTER REFER TO SNAPNRACK ENGINEERING CHARTS FOR APPLICABLE RAIL SPANS. "BIN" NUMBER ON CHART SHOULD MATCH "BIN" NUMBER ON THIS DRAWING (X2) #14 FULLY THREADED WOOD SCREWS, S.S. MUST PENETRATE A MIN. OF 11 2" INTO STRUCTURAL MEMBER. (X2) #14 FULLY THREADED WOOD SCREWS, S.S. MUST EMBED FULLY INTO WOOD DECK REFER TO SNAPNRACK INSTALLATION MANUAL FOR 5 16"Ø HARDWARE TORQUE SPECIFICATIONS SNAPNRACK SPEEDSEAL DECKFOOT CAN MOUNT IN ANY ORIENTATION ON THE ROOF RAIL CAN MOUNT ON BOTH SIDES OF SPEEDSEAL DECKFOOT FOR ADDITIONAL LEVELING DETAILS, REFER TO SNAPNRACK DETAIL DRAWING "SNR-DC-00447 ULTRA RAIL, COMPONENT DETAIL, ULTRA RAIL LEVELING SPACER" B 8/2/2021 DC000595 MJA 3 6/13/2024 REMOVE MIN DECK THICKNESS KMA 3.860 2.080 ROOF DECKING STRUCTURAL MEMBER (RAFTER) COMP SHINGLE ROOFING, TYP. (X2) #14 FULLY THREADED WOOD SCREW S.S. MUST EMBED FULLY INTO WOOD DECK (X2) #14 FULLY THREADED WOOD SCREW S.S. INTO STRUCTURAL MEMBER. SIZE LENGTH APPROPRIATELY ATTACHMENT DETAIL MINIMUM RAFTER PENETRATION: 11 2" MODULE HEIGHT MAX: UR-40 = 43 8" UR-60 = 5"SCREW HEIGHT OFF ROOF: 9 16" SNAPNRACK, ULTRA RAIL COMP SHINGLE ROOFING, TYP. ROOF DECKING WOOD RAFTER, TYP. (STRUCTURAL MEMBER) EXPLODED 5 16" Ø-18 X 13 4" BOLT, SERRATED FLANGE, S.S. COIL SPRING FOR 3 8" Ø BOLT, S.S. (OPTIONAL) SNAPNRACK, SPEEDSEAL DECKFOOT BASE, SEALING SNAPNRACK, UR MOUNT THRU SNAPNRACK, UR MOUNT TAPPED UR-40 RAIL | UR-60 RAIL FOR USE WITH SNAPNRACK ULTRA SERIES RAILS 15 8" 11 2" 11 2" 21 4" SCALE: DATE: NTS 6/13/2024 DRAWING NUMBER: SNR-DC-00449 REV: 3 Sunrun South LLC 595 MARKET STREET, 29TH FLOOR  SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900  FAX (415) 580-6902 THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. DESCRIPTION: ULTRA RAIL, ATTACHMENT DETAIL, UR SPEEDSEAL DECKFOOT TO RAFTER Exp. 12/31/2024 Signed On: 9/24/2024 PAGE REV: A1 9/17/2024 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 KIM HA NGUYEN 1227 W RIVER LN, SANTA ANA, CA, 92706 PROJECT NUMBER: SC1800916342 SHEET DESIGNER: FRENCE RETONE CUSTOMER RESIDENCE: TEL. (714) 675-1274 APN: 00113716 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 M 240V METER SOCKET 125A CONTINUOUS & 240V METER 200A, FORM 2S (E) SUN RUN CENTRON 4G METER EXISTING 200A MAIN BREAKER (END FED) FACILITY GROUND(E) 25A PV BREAKER AT OPPOSITE END OF BUSBAR M METER #: SCE 222013-154795 120/240 VAC SINGLE PHASE SERVICE UTILITY GRID EXISTING 200A MAIN PANEL FACILITY LOADS 200 A MAIN BUS (E) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D 3R, 30A,2P 120/240VAC 3 3 3 1 2 JUNCTION BOX OR EQUIVALENT ABB: PVI-4.2-OUTD-S-US-A (240 V) 4200 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI PV MODULES JA SOLAR: JAM54S31-405/MR (7) MODULES (1) STRING OF (7) MODULES PV MODULES JA SOLAR: JAM54S31-405/MR (7) MODULES (1) STRING OF (7) MODULES CONDUIT SCHEDULE #CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER 2 3/4" EMT OR EQUIV.(4) 10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2 3 EXISTING EXISTING EXISTING EXISTING PV-4.0 ELECTRICAL #ESTAMP GENERAL NOTES: • CITY REQUIRES TWO SOURCES OF GROUND - UFER, TWO GROUNDS RODS OR COLD WATER GAS BOND • 260.61 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. SYSTEM CHARACTERISTICS - INVERTER 1 SYSTEM SIZE: SYSTEM OPEN CIRCUIT VOLTAGE: SYSTEM OPERATING VOLTAGE: MAX ALLOWABLE DC VOLTAGE: SYSTEM OPERATING CURRENT: SYSTEM SHORT CIRCUIT CURRENT: 5670 W 280.32 V 218.47 V 600 V 25.96 A 34.68 A MODULE CHARACTERISTICS JA SOLAR: JAM54S31-405/MR: OPEN CIRCUIT VOLTAGE: MAX POWER VOLTAGE: SHORT CIRCUIT CURRENT: 405 W 37.23 V 31.21 V 13.87 A PAGE REV: A1 9/17/2024 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 KIM HA NGUYEN 1227 W RIVER LN, SANTA ANA, CA, 92706 PROJECT NUMBER: SC1800916342 SHEET DESIGNER: FRENCE RETONE CUSTOMER RESIDENCE: TEL. (714) 675-1274 APN: 00113716 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 PV-4.1 ELECTRICAL CALCS #ESTAMP System Information 5.265 kW DC Photovoltaic System (13) JA Solar: JAM54S31-405/MR, ABB: PVI-4.2-OUTD-S-US-A (240 V) Allowable Backfeed Allowable Backfeed = (Main Panel Rating) x 1.2 - (Main Breaker Rating) = 200A x 1.2 - 200A = 40A 25A ≤ 40A → Interconnection meets 705.12(D)(2) requirements. Inverter Overcurrent Protection (Inverter Max Current) x (Continuous Load) = 20 A x 1.25 = 25 A → 25 A Overcurrent Protection Per Manufacturer DC Wire Sizing Max Circuit Current = (Module Isc) x (High Irradiance)[690.8(A)(1)] x (Continuous Load)[690.8(B)(1)]= 13.87A x 1.56 = 21.64A Adjusted Conductor Ampacity = (High Temp)[Table 310.15(B)(2)(a)] x (Conduit Fill)[Table 310.15(B)(3)(a)] x (Conductor Ampacity)[Table 310.15(B)(16)] = 0.91 x 0.8 x 40A = 29.12A Terminal Rating[110.14(C)] = 10 AWG, 75°C Rated = 35A 29.12A < 35A → Adjusted conductor ampacity governs conductor sizing. 21.64A < 29.12A → 10 AWG Ampacity OK Therefore 10 AWG is sufficient. AC Wire Sizing Max AC Output Current = (Max Inverter Output) x (Continuous Load)[210.19(A)(1)] = 20 A x 1.25 = 25 A Adjusted Conductor Ampacity = (High Temp)[Table 310.15(B)(2)(a)] x (Conduit Fill)[Table 310.15(B)(3)(a)] x (Conductor Ampacity)[Table 310.15(B)(16)] = 0.91 x 1 x 40A = 36.4A Terminal Rating[110.14(C)] = 10 AWG, 75°C Rated = 35A 35A < 36.4A → Terminal rating governs conductor sizing. 25A < 35A → 10 AWG Ampacity OK Therefore 10 AWG is sufficient. System Characteristics Operating Voltage = (Module VMP) x (# Modules / String) = 31.21 V x 7 = 218.47 V Max Open Circuit Voltage = {[((Temp Coef VOC) x (VOC)) / 100] x [Low Temp - STC Temp] + VOC} x (# Modules / String) = {[(-0.28 %/°C x 37.23 V) / 100] x [-2 °C - 25 °C] + 37.23 V} x 7 = 280.32 V Operating Current = (Module IMP) * (# Strings) = 12.98 A x 2 = 25.96A Short Circuit Current = 1.25 x (Module Isc) x (# Strings) 1.25 x 13.87 A x 2 = 34.68A PAGE REV: A1 9/17/2024 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 KIM HA NGUYEN 1227 W RIVER LN, SANTA ANA, CA, 92706 PROJECT NUMBER: SC1800916342 SHEET DESIGNER: FRENCE RETONE CUSTOMER RESIDENCE: TEL. (714) 675-1274 APN: 00113716 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 SIGNAGE PV-5.0 #ESTAMP NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE 2013 CEC ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. WARNING! SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM DUAL POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): CEC 2016: 705.12(D)(3), NEC 2014: 705.12(D)(3), NEC 2011: 705.12(D)(4) WARNING: PHOTOVOLTAIC POWER SOURCE WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): CEC 2016: 690.31(G)(3), 690.31(G)(4), NEC 2014: 690.31(G)(3), 690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012: 605.11.1.4 PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): CEC 2016: 690.12, NEC 2014: 690.12, IFC 2012: 605.11.1 PHOTOVOLTAIC DC DISCONNECT RATED MAXIMUM POWER-POINT CURRENT: RATED MAXIMUM POWER-POINT VOLTAGE: MAXIMUM SYSTEM VOLTAGE: MAXIMUM SHORT CIRCUIT CURRENT: ADC VDC VDC ADC 25.96 218.47 280.32 34.68 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): CEC 2016: 690.53, NEC 2014: 690.53, NEC 2011: 690.53 INVERTER 1 ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING! LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2016: 690.17(E), NEC 2014: 690.17(E), NEC 2011: 690.17(4) LABEL LOCATION: INSTALLED WITHIN 3' OF RAPID SHUT DOWN SWITCH PER CODE(S): CEC 2016: 690.12, NEC 2014: 690.12, NEC 690.56, IFC 2012: 605.11.1 RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED ELECTRICAL SHOCK HAZARD WARNING! LABEL LOCATION: INVERTER(S), DC DISCONNECTS. PER CODE(S): CEC 2016: 690.35(F), NEC 2014: 690.35(F), NEC 2011: 690.35(F) ! DO NOT ADD LOADS PHOTOVOLTAIC SYSTEM COMBINER PANEL WARNING LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): CEC 2016: 705.12(D)(2)(3)(c), NEC 2014: 705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4) MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 20 AMPS 240 VAC PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2016: 690.54, NEC 2014: 690.54, NEC 2011: 690.54 WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): CEC 2016: 705.12(D)(2)(3)(b), NEC 2014: 705.12(D)(2)(3)(b), NEC 2011: 705.12(D)(7) POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN CAUTION: 1227 W RIVER LN, SANTA ANA, CA, 92706 SOLAR PANELS ON ROOF SERVICE ENTRANCE AND PV BREAKER DISCONNECT AC DISCONNECT SUNRUN METER INVERTER (EXT) RAPID SHUTDOWN SWITCH Docusign Envelope ID: A0157799-6800-43FA-9FBC-953EDA0092A9 1227 W RIVER LN, SANTA ANA CA 92706 714-675-1274evewin2001@gmail.com 12/6/2024 Khiem Nguyen r rf O P CAII.OA001A C:l C: DIE PAPrWPV Or CONSUftlA A/rA,tr. CONTRACTORS STATE LICENSE BOARD License Number 765730 ACTIVE LICENSE I OW tft, INDIV CITY OF SANTA ANA Planning and Building Agency Approved FOR PERMIT ISSUANfm6 Business Name JASON POCH DBA SUNCORE SOLAR Classirficatlon(s) C 10 f xpiratlon Uatr 07/31/2025 www cslb ca gov SAA ANA nd Building Agency aF :3 n -proved C = MIT ISSUANCE O co D _ eD T a n O m -' 3 :3 c o m ul a �, D ro � �} � a C 0 _ �. a r+ Q x O' Z-m C j �D a) n (OJ1 0 < - ul r-0 O a CD o �, a a a �, cv 3 Cy N N'Cc _ Cl � C O 3 r_ v Lo < C to (D ? fD ^ rD O Q � �..L ^ (D na,� v x ° o D O O ' _ (D x a C < OD C O :3C O w m a ? o -. O cQ ? ('D o � � a n� J —C—tTY OF SANTA ANA- Planning and Building Age cy Approved FOR PERMIT ISSUANCE Mas *Suncore Solar License 4765730 l Jason Poch, authorize Jaxon Wright to pull city business license and permits on my behalf under our contractors license. Ca License #765730 Thank you J on P,�\ Suncore Solar Please See Attached Form For Notary Dated: J U Planning and Builditg Agency ACKNOWLEDGMENT A notary public or other officer completing this certificate verifies only the identity of the individual who signed the document to which this certificate is attached, and not the truthfulness, accuracy, or validi of that document State of California County of ORANGE ) Approvd FOR PERMIT IS ANCE Master ID: Date: On June 21 2W "I before me, Darby Payne Hawke Driskill Notary Public (insert name and title of the officer) personally appeared Jason rG N who proved to me on the basis of satisfactory evidence to be the person(Kwhose name( is/are subscribed to the within instrument and acknowledged to me that he/sw/tha9 executed the same in hislkr¢r/tKeir authorized capacity(ios), and that by his/h6r/their signature(spron the instrument the person(py, or the entity upon behalf of which the person(sr) acted, executed the instrument I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct WITNESS my hand and Signature .................................... ), DARBY PAYNE k1b HAWKE DRISKILL seal. COMM a 2382150 x ORANGE County VCanforma Notary Public Comm Exp Nov. 7. 2025 (Seal) ............................ To Whom It May Concern: I am writing to confirm that I, ___________________, am aware that Suncore solar has been contacted to perform the installation of new equipment on my home located at ___________________________________________. Additionally, this letter acknowledges that if any other company has submitted a permit for this work, this serves as my authorization to void that permit on my behalf, as Suncore Solar is the company I have contracted for this project. Should you have any questions or require further documentation, please feel free to contact me directly at ______________________ or _________________________. Thank you for your attention to this matter. Sincerely, ________________________________________________________ Name ________________________________________________________ Date Docusign Envelope ID: 71303D2C-EE19-43AF-A645-787E7486BFA6 Khiem and Kim Ha Nguyen evewin2001@gmail.com(714) 675-1274 3/18/2025 1227 W River Ln Santa Ana, CA 92706 To Whom It May Concern: I am writing to confirm that I, ___________________, am aware that Suncore solar has been contacted to perform the installation of new equipment on my home located at ___________________________________________. Additionally, this letter acknowledges that if any other company has submitted a permit for this work, this serves as my authorization to void that permit on my behalf, as Suncore Solar is the company I have contracted for this project. Should you have any questions or require further documentation, please feel free to contact me directly at ______________________ or _________________________. Thank you for your attention to this matter. Sincerely, ________________________________________________________ Name ________________________________________________________ Date Docusign Envelope ID: 71303D2C-EE19-43AF-A645-787E7486BFA6 Khiem and Kim Ha Nguyen evewin2001@gmail.com(714) 675-1274 3/18/2025 1227 W River Ln Santa Ana, CA 92706 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org Certificate Of Completion Envelope Id: A0157799-6800-43FA-9FBC-953EDA0092A9 Status: Completed Subject: Complete with Docusign: Customer Letter.pdf Source Envelope: Document Pages: 1 Signatures: 1 Envelope Originator: Certificate Pages: 3 Initials: 0 Jaxson Wright AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) permits.suncore@Gmail.com IP Address: 69.129.120.22 Record Tracking Status: Original 12/5/2024 6:55:11 AM Holder: Jaxson Wright permits.suncore@Gmail.com Location: DocuSign Signer Events Signature Timestamp Khiem Nguyen evewin2001@gmail.com Security Level: Email, Account Authentication (None) Signature Adoption: Pre-selected Style Using IP Address: 172.58.113.106 Sent: 12/5/2024 6:56:15 AM Viewed: 12/6/2024 5:24:45 PM Signed: 12/6/2024 5:25:53 PM Electronic Record and Signature Disclosure: Accepted: 12/6/2024 5:24:45 PM ID: b580cbd9-7440-4ef0-b8d4-9eed84d562a1 In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 12/5/2024 6:56:15 AM Certified Delivered Security Checked 12/6/2024 5:24:45 PM Signing Complete Security Checked 12/6/2024 5:25:53 PM Completed Security Checked 12/6/2024 5:25:53 PM Payment Events Status Timestamps Electronic Record and Signature Disclosure ELECTRONIC RECORD AND SIGNATURE DISCLOSURE From time to time, Jaxson Wright (we, us or Company) may be required by law to provide to you certain written notices or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures electronically through the DocuSign system. Please read the information below carefully and thoroughly, and if you can access this information electronically to your satisfaction and agree to this Electronic Record and Signature Disclosure (ERSD), please confirm your agreement by selecting the check-box next to ‘I agree to use electronic records and signatures’ before clicking ‘CONTINUE’ within the DocuSign system. Getting paper copies At any time, you may request from us a paper copy of any record provided or made available electronically to you by us. You will have the ability to download and print documents we send to you through the DocuSign system during and immediately after the signing session and, if you elect to create a DocuSign account, you may access the documents for a limited period of time (usually 30 days) after such documents are first sent to you. After such time, if you wish for us to send you paper copies of any such documents from our office to you, you will be charged a $0.00 per-page fee. You may request delivery of such paper copies from us by following the procedure described below. Withdrawing your consent If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and disclosures electronically is described below. Consequences of changing your mind If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can complete certain steps in transactions with you and delivering services to you because we will need first to send the required notices or disclosures to you in paper format, and then wait until we receive back from you your acknowledgment of your receipt of such paper notices or disclosures. Further, you will no longer be able to use the DocuSign system to receive required notices and consents electronically from us or to sign electronically documents from us. All notices and disclosures will be sent to you electronically Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you through the DocuSign system all required notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the disclosures and notices electronically or in paper format through the paper mail delivery system. If you do not agree with this process, please let us know as described below. Please also see the paragraph immediately above that describes the consequences of your electing not to receive delivery of the notices and disclosures electronically from us. How to contact Jaxson Wright: You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as follows: To contact us by email send messages to: permits.suncore@Gmail.com To advise Jaxson Wright of your new email address To let us know of a change in your email address where we should send notices and disclosures electronically to you, you must send an email message to us at permits.suncore@Gmail.com and in the body of such request you must state: your Electronic Record and Signature Disclosure created on: 11/26/2024 2:42:50 PM Parties agreed to: Khiem Nguyen previous email address, your new email address. We do not require any other information from you to change your email address If you created a DocuSign account, you may update it with your new email address through your account preferences. To request paper copies from Jaxson Wright To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically, you must send us an email to permits.suncore@Gmail.com and in the body of such request you must state your email address, full name, mailing address, and telephone number. We will bill you for any fees at that time, if any. To withdraw your consent with Jaxson Wright To inform us that you no longer wish to receive future notices and disclosures in electronic format you may: i. decline to sign a document from within your signing session, and on the subsequent page, select the check-box indicating you wish to withdraw your consent, or you may; ii. send us an email to permits.suncore@Gmail.com and in the body of such request you must state your email, full name, mailing address, and telephone number. We do not need any other information from you to withdraw consent. The consequences of your withdrawing consent for online documents will be that transactions may take a longer time to process. Required hardware and software The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found here: https://support.docusign.com/guides/signer-guide-signing-system-requirements. Acknowledging your access and consent to receive and sign documents electronically To confirm to us that you can access this information electronically, which will be similar to other electronic notices and disclosures that we will provide to you, please confirm that you have read this ERSD, and (i) that you are able to print on paper or electronically save this ERSD for your future reference and access; or (ii) that you are able to email this ERSD to an email address where you will be able to print on paper or save it for your future reference and access. Further, if you consent to receiving notices and disclosures exclusively in electronic format as described herein, then select the check- box next to ‘I agree to use electronic records and signatures’ before clicking ‘CONTINUE’ within the DocuSign system. By selecting the check-box next to ‘I agree to use electronic records and signatures’, you confirm that: You can access and read this Electronic Record and Signature Disclosure; and You can print on paper this Electronic Record and Signature Disclosure, or save or send this Electronic Record and Disclosure to a location where you can print it, for future reference and access; and Until or unless you notify Jaxson Wright as described above, you consent to receive exclusively through electronic means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you by Jaxson Wright during the course of your relationship with Jaxson Wright.