HomeMy WebLinkAbout1222 S Linda Way - PlanPROJECT
LOCATION
SHEET REFERENCE:
SHEET: OF
SHEET INFO:
REVISION DATE:
ME
R
C
U
R
Y
I
N
S
U
R
A
N
C
E
,
I
N
C
.
PR
O
J
E
C
T
:
CL
I
E
N
T
:
CA
H
O
-
0
0
2
5
0
9
9
4
SHEET TITLE:
JE
R
R
Y
N
G
O
JOB NO.
SCALE:
DATE:
DESIGNER: BS
25-0001
01/17/25
DRAFTER: AG
PR
O
P
E
R
T
C
L
A
I
M
S
A
D
J
U
S
T
E
R
10
4
8
I
R
V
I
N
E
A
V
E
N
U
E
,
S
U
I
T
E
1
0
8
7
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
0
PH
O
N
E
:
9
4
9
-
2
5
9
-
6
0
8
0
BR
Y
A
N
@
S
T
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
ST
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
12
2
2
S
O
U
T
H
L
I
N
D
A
W
A
Y
21
S-3
DESCRIPTIONSHEET #
S-1 SPECIFICATIONS SHEET 1
S-2
S-5
ABBREVIATIONS FRAMING NOTES
SHOP DRAWING SUBMITTALS
PROJECT INFORMATION
SYMBOLS AND LEGENDS
SOIL AND FOUNDATION INFORMATION
PROJECT DESIGN PARAMETERS
SHEET INDEX
ICC
I.D.
IN.
INFO.
INT.
J.T.
K
KSI
L
L.A.R.R.
LB
L.L.
LLH
LLV
LONG.
LT.
MATL
MAX.
M.B.
MED.
MEZZ.
M.F.
INTERNATIONAL CODE COUNCIL
INSIDE DIAMETER
INCH
INFORMATION
INTERIOR
JACK TRUSS
KIP
KIPS PER SQUARE INCH
LOS ANGELES RESEARCH
REPORT
ANGLE
POUND
LIVE LOAD
LONG LEG HORIZONTAL
LONG LEG VERTICAL
LONGITUDINAL
LIGHT
MATERIAL
MAXIMUM
MACHINE BOLT
MEDIUM
MEZZANINE
MOMENT FRAME
MFR.
MIN.
MISC.
ML
N.G.
N.T.S.
O/
O.C.
O.D.
OPP.
OPNG.
OSB
MANUFACTURER
MINIMUM
MISCELLANEOUS
MICROLAM
NATURAL GRADE
NOT TO SCALE
OVER
ON CENTER
OUTSIDE DIAMETER
OPPOSITE
OPENING
ORIENTED STRAND BOARD
P.C.
PCF
PL
PLF
PLY.
PSF
PSI
P.T.
P.T.D.F.
QTY.
R.D.
REF.
PRECAST CONCRETE
POUNDS PER CUBIC FOOT
PARALLAM
POUNDS PER LINEAR FOOT
PLYWOOD
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
POST TENSION
PRESSURE TREATED DOUGLAS FIR
QUANTITY
ROOF DRAIN
REFERENCE
REINF.
REQ'D
REV
R.J.
R.O.
R.R.
R.T.
SCHED.
SECT
S.C.
SHTG.
SIM.
REINFORCEMENT
REQUIRED
REVISION
ROOF JOIST
ROUGH OPENING
ROOF RAFTER
ROOF TRUSS
SCHEDULE
SECTION
SLIP CRITICAL
SHEATHING
SIMILAR
SPEC.
SQ. FT.
S.S.
STL.
STAGG.
STD.
STIFF.
S.W.
SYM.
T&B
T&G
TEMP.
THK.
T.N.
T.O.B.
T.O.C.
T.O.F.
T.O.S.
T.O.W.
TRANS.
T.S.
TYP.
U.N.O.
VAR.
W
W/
W.L.
WT.
W.W.F.
SPECIFICATION
SQUARE FOOT
SELECT STRUCTURAL
STEEL
STAGGERED
STANDARD
STIFFENER
SHEAR WALL
SYMMETRIC
TOP AND BOTTOM
TONGUE AND GROOVE
TEMPORARY
THICK
TOE NAIL
TOP OF BEAM
TOP OF CONCRETE
TOP OF FOOTING
TOP OF STEEL
TOP OF WALL
TRANSVERSE
TIMBERSTRAND
TYPICAL
UNLESS NOTED OTHERWISE
VARIES
WIDE FLANGE
WITH
WIND LOAD
WEIGHT
WELDED WIRE FABRIC
W/ WITHOUT
A.B.
ABV.
ACI
ADD'L
ADJ.
AISC
ALT
ANSI
APP
ARCH.
ASTM.
ANCHOR BOLT
ABOVE
AMERICAN CONCRETE INSTITUTE
ADDITIONAL
ADJACENT
AMERICAN INSTITUTE STEEL
ALTERNATE
AMERICAN NATIONAL STANDARDS
APPROXIMATE
ARCHITECTURAL/ARCHITECT
AMERICAN SOCIETY FOR TESTING
AND MATERIALS
AITC
&
@
BLDG.
BLKG.
BLW.
BM.
B.N.
B.O.B.
BOT.
B.P.
AMERICAN INSTITUTE OF TIMBER
CONSTRUCTION
AND
AT
BUILDING
BLOCKING
BELOW
BEAM
BOUNDARY NAILING
BOTTOM OF BEAM
BOTTOM
BASE PLATE
BRCG.
BRG.
B.S.
C
CBC
C.J.
CL
CLG.
CLR.
CMU
COL.
CONC.
BRACING
BEARING
BOTH SIDES
CHANNEL
CALIFORNIA BUILDING CODE
CEILING JOIST
CENTER LINE
CEILING
CLEAR
CONCRETE MASONRY UNIT
COLUMN
CONCRETE
CONN.
CONST.
CONT.
C.J.P.
CU.FT
C.W.
d
DBL.
DEG.
DEPT.
DET.
D.F.
CONNECTION
CONSTRUCTION
CONTINUOUS
COMPLETE JOINT PENETRATION
CUBIC FEET
CUT WASHER
PENNY WEIGHT
DOUBLE
DEGREE
DEPARTMENT
DETAIL
DOUGLAS FIR
DIA.
DIAG.
DIM.
DIST.
D.J.
D.L.
DN
DO
D.S.
DSA
D.T.
DWG.
EA.
E.F.
E.G.
E.S.
ELEV.
E.N.
E.O.R.
EQ.
ETC.
EVA
E.W.
EXIST.
EXP.
EXT.
FEMA
FND.
DIAMETER
DIAGONAL
DIMENSION
DISTANCE
DECK JOIST
DEAD LOAD
DOWN
DITTO
DOWN SPOUT
DIVISION OF THE STATE ARCHITECT
DRAG TRUSS
DRAWING
EACH
EACH FACE
EXISTING GRADE
EACH SIDE
ELEVATION
EDGE NAILING
ENGINEER OF RECORD
EQUAL
ETCETERA
EMERGENCY VEHICLE ACCESS
EACH WAY
EXISTING
EXPOSURE
EXTERIOR
FEDERAL EMERGENCY
MANAGEMENT AGENCY
FOUNDATION
FAB FABRICATED(OR)
INSTITUTE
CONSTRUCTION
FIN.
F.F.
F.G.
F.H.
F.J.
FLR.
F.O.C.
F.O.M.
F.R.C.
F.R.T.
FRMG.
F.S.
F.T.
FT.
FTG.
GA
GALV.
G.C.
GLB
G.T.
GYP.
HD
HDR.
HGR.
HS
HSS
HT.
FINISH
FINISH FLOOR
FINISH GRADE
FULL HEIGHT
FLOOR JOIST
FLOOR
FACE OF CONCRETE
FACE OF MASONRY
FIBER REINFORCED CONRETE
FIRE RETARDANT TREATED
FRAMING
FINISH SURFACE
FLOOR TRUSS
FEET/FOOT
FOOTING
GAUGE
GALVANIZED
GENERAL CONTRACTOR
GLULAM BEAM
GIRDER TRUSS
GYPSUM
HOLDOWN
HEADER
HANGER
HIGH STRENGTH
HOLLOW STRUCTURAL STEEL
HEIGHT
HORIZ. HORIZONTAL
IBC INTERNATIONAL BUILDING CODE
1. THE GENERAL CONDITIONS, SPECIFICATIONS, AND STRUCTURAL DETAILS
ON ALL SHEETS APPLY TO THE WORK.
2. CONTRACTOR SHALL CHECK FRAMING DIMENSIONS AGAINST THE
ARCHITECTURAL PLAN AND NOTIFY THE ARCHITECT AND ENGINEER OF
ANY OMISSIONS AND/OR DISCREPANCIES BEFORE STARTING WORK.
3. ALL SHEAR CONNECTORS AND BLOCKING MUST BE INSTALLED PRIOR TO
THE INSTALLATION OF ROOF AND FLOOR SHEATHING.
4. USE SIMPSON U-HANGER FOR 2X FLOOR JOIST TO FLUSH BEAM
CONNECTION U.N.O.
5. USE SIMPSON FULL DEPTH HU-HANGER (MAX - FILL ALL HOLES INCLUDING
TRIANGLE HOLES) FOR BEAM TO BEAM CONNECTIONS, U.N.O.
6. CARRY ALL MULTIPLE STUDS OR POSTS FROM FLOOR ABOVE DOWN TO
FLOOR BELOW OR BEAM BELOW. PROVIDE SOLID BLOCKING AT FLOOR
LEVEL TO TRANSFER LOAD FROM UPPER POST TO LOWER POST.
7. PROVIDE POST/MULTI-STUD (U.N.O.) IN WALL TO SUPPORT FLUSH BM.
8. NO UTILITY LINE PENETRATION (STRUCT. SHTG, DBL TOP PLATES,
SILL/SOLE PLATES, BLKG ABV & BLW) AT SHEAR WALL IN EXCESS OF
ALLOWABLE PENETRATION SHOWN IN DETAILS IS ALLOWED.
9. INTERIOR NON-BEARING WALL TOP PLATE MAY BE 1X4 OVER 2X4.
10. TOP PLATE SPLICES PER DETAIL PROVIDED, TYP.
11. INSTALL 2-MSTA36 STRAPS AT TOP PLATE OF 4" TO 6" STRUCTURAL WALL
TRANSITIONS, TYP.
12. EXTEND FLOOR/ROOF SHEATHING TO ANY/ALL BUILDING POP-OUTS.
1
SW1
DETAIL NUMBER
SHEET NUMBER
REVISION NUMBER
REVISION AREA
1. THE FOUNDATION DESIGN IS BASED ON PRESUMPTIVE VALUES BASED ON
THE 2022 CBC.
2. SUB-GRADE PREPARATION, FOUNDATION TRENCH, BACK FILL AND ALL
FOUNDATION PADS SHALL BE APPROVED AND CERTIFIED BY THE
CERTIFIED BUILDING OFFICIAL AND THE BUILDING INSPECTOR.
3. TRENCHES WITHIN THE INFLUENCE OF THE BUILDING FOUNDATION FOR
THE UNDERGROUND UTILITIES MUST BE BACK FILLED WITH PROPER
MATERIAL AND THE BACKFILL MATERIAL MUST BE PROPERLY COMPACTED
TO THE SATISFACTION OF THE CERTIFIED BUILDING OFFICIAL AND THE
BUILDING INSPECTOR.
4. CONTRACTOR TO ENSURE THAT ALL DRAINAGE IS DIRECTED AWAY FROM
THE EXTERIOR FOOTINGS (MIN. 2% SLOPE).
1. THE CONTRACTOR SHALL SUPPLY THE EOR/ARCHITECT WITH A MIN. OF
TWO COPIES OF CHECKED SHOP DRAWINGS BEARING THE CONTRACTOR'S
STAMP OF APPROVAL AND SIGNATURE A MIN. OF THREE WEEKS PRIOR TO
FABRICATION. THE REVIEW OF SHOP DRAWINGS BY THE ENGINEER IS
ONLY FOR GENERAL COMPLIANCE WITH THE STRUCTURAL DRAWINGS AND
SPECIFICATIONS. THIS REVIEW DOES NOT GUARANTEE IN ANY WAY THAT
THE SHOP DRAWINGS ARE CORRECT, COMPLETE, NOR DOES IT INFER
THAT THEY SUPERSEDE THE STRUCTURAL DRAWINGS.
2. SHOP DRAWINGS ARE AN AID FOR FIELD PLACEMENT, AND ARE
SUPERSEDED BY THE STRUCTURAL DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE GENERAL CONTRACTOR TO MAKE CERTAIN THAT
ALL CONSTRUCTION IS IN FULL AGREEMENT WITH THE LATEST
STRUCTURAL DRAWINGS. A SET OF REVIEWED SHOP DRAWINGS MUST BE
FILED WITH THE LOCAL JURISDICTION BY THE CONTRACTOR AND A SET
PLACED AT THE JOB SITE.
SHOP DRAWINGS/SUBMITTALS SHALL BE PROVIDED FOR THE FOLLOWING
CHECKED ITEMS.
REBAR, PT, & STUD RAILS
MAT SLAB, PAD & CONT. FTGS
PERIMETER & INTERIOR WALLS
SHEAR WALL GRADE BEAMS
ELEVATED SLABS INCLUDING BEAMS, DROPS,
PT TENDON & EFFECTIVE FORCE CALCULATIONS
CMU BLOCK & GROUT
CONCRETE MIX DESIGNS FOR ALL ELEMENTS
CAPS, DROP PANELS, ETC.
COLUMNS
BUILDING
OFFICIALE.O.R.SHOP DRAWING/SUBMITTAL
ELEVATED SLAB FORMING PLAN/SHORING PLAN
ELEVATED SLAB CONSRTUCTION JOINT LAYOUT
MECHANICAL AND PLUMBING LAYOUT PLANS
ELECTRICAL LAYOUT PLANS
FIRE PROTECTION PLAN AND DETAILS
STRUCTURAL STEEL SHOP DRAWINGS
ROOF TRUSS (&/OR FLOOR TRUSS) SHOP DWGS
PREFABRICATED STAIR UNITS & CONNECTIONS
ELEVATOR & CONNECTIONS TO THE STRUCTURE
SHEAR WALL TIE-DOWN SHOP DRAWINGS
SLAB ON GRADE DRAWINGS
3. SHOP DRAWINGS/SUBMITTALS PROCESS:
x THE LISTED DEFERRED SUBMITTAL ITEMS MUST BE REVIEWED AND
APPROVED BY THE GENERAL CONTRACTOR PRIOR TO SUBMITTAL TO THE
ARCHITECT FOR COORDINATION. THE ARCHITECT SHALL FORWARD
TWO(2) COPIED OF THE SUBMITTAL TO THE ENGINEER OF RECORD FOR
REVIEW. SUBMITTALS REQUIRING REVIEW BY THE BUILDING OFFICIAL
INCLUDE A CHECK IN THE "BUILDING OFFICIAL" COLUMN. IT IS THE
CONTRACTORS RESPONSIBILITY TO DETERMINE TURN-AROUND TIME OF
EACH PARTY AND TO MAKE APPROPRIATE TIME ALLOWANCES.
x PLANS FOR THE DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED IN A
TIMELY MANNER THAT ALLOWS A MINIMUM OF 15 WORKING DAYS FOR
INITIAL PLAN REVIEW. ALL COMMENTS RELATED TO THE DEFERRED
SUBMITTALS MUST BE ADDRESSED TO THE SATISFACTION OF THE
REVIEWING PARTIES PRIOR TO FABRICATION AND DELIVERY OF THE
SUBMITTAL ITEMS.
x SUBMITTALS MAY BE SUBMITTED ELECTRONICALLY TO THE EOR IN THE
SAME MANNER AS HARD COPIES AS DESCRIBED ABOVE.
SPECIFICATIONS SHEET 2
SPECIFICATIONS SHEET 3
CLIENT: MERCURY INSURANCE, INC.
PROJECT
ADDRESS: 1222 SOUTH LINDA WAY
SANTA ANA, CA 92704
JURISDICTION: PER CODE
APPLICABLE CODE(S): 2022 CBC
SSE PROJECT NUMBER: 25-0001
CONTACT PRINCIPAL: BRYAN STREGE, PE, SE
CONTACT PHONE: (949)259-6080
CONTACT EMAIL: BRYAN@STREGESTRUCTURAL.COM
1. CONSTRUCTION TYPE TYPE V-B WOOD CONSTRUCTION
2. RISK CATEGORY II
3. SEISMIC DESIGN PARAMETERS:
SITE DATA TYPE V BUILDING DATA
S 1.297
S 0.4631
S 1.037
S 0.571d1
ds
s
SITE CLASS D
1.2
1.85
F a
F v
SEISMIC FORCE-
RESISTING SYSTEM
I
PROCEDURE
R
Cs
V
p
SDC
BEARING WALL SYSTEM:
LIGHT-FRAME WOOD WALL
W/ SHEAR PANEL OF
1.0
EQUIVELANT
2.0
0.363
Cs x Wd
1.0
D
LATERAL FORCE
4. WIND DESIGN
WIND SPEED 95 MPH (ULTIMATE)
WIND EXPOSURE EXP. C
5. BUILDING ASSEMBLIES:
ROOF ASSEMBLY ASPHALT SHINGLE/WATERPROOFING
O/ WOOD SHEATHING
WALL ASSEMBLY FINISH
EXTERIOR WALL STUCCO
INTERIOR WALL GYPSUM BOARD
ASSEMBLY WEIGHTS: DL (PSF) LL (PSF)
ROOF 15 20
EXTERIOR WALLS 18
INTERIOR WALLS 9
THE E.O.R. MUST BE NOTIFIED IF:
x THE WALL/CEILING FINISH MATERIAL(OTHER THAN EXTERIOR SKIN) IS
OTHER THAN DRYWALL, ALSO KNOWN AS SHEETROCK & GYPSUM BOARD.
x THE DRY WALL MATERIAL WEIGHS MORE THAN 2.2 PSF.
x THE DRY WALL MATERIAL IS GREATER THAN 5/8" THICK.
x THERE IS ANY FUTURE SOLAR REQUIREMENTS FOR THE ROOF.
S-6
S-7 STRUCTURAL ROOF FRAMING PLAN
PROJECT SCOPE
1. BRING SUBJECT SINGLE-FAMILY RESIDENTIAL STRUCTURE BACK TO
PRE-LOSS STATE DUE TO A FIRE LOSS EVENT. (REPAIR ONLY, NO
ALTERATION FROM EXISTING.)
S-4
SITE PLAN
S-8
S-9
SITE PLAN
LAYOUT PLAN
STRUCTURAL FOUNDATION/ FRAMING PLAN
E-2
E-1
E-3
ELECTRICAL NOTES, LEGENDS & SCHEDULES
ELECTRICAL SPECIFICATIONS
ELECTRICAL LIGHTING PLAN
STRUCTURAL DETAIL SHEET 1
STRUCTURAL DETAIL SHEET 2
1
S-1
SPECIFICATIONS
SHEET 1
OTHER MATERIALS
E-4
ELECTRICAL POWER PLAN
M-1 MECHANICAL NOTES & LEGENDS
M-2 MECHANICAL FLOOR PLAN
M-3 MECHANICAL SCHEDULES & DETAILS
M-4 MECHANICAL SPECIFICATIONS
P-1 PLUMBING NOTES & LEGENDS
P-2 PLUMBING FLOOR PLAN
P-3 PLUMBING SCHEDULES & DETAILS
P-4 PLUMBING SPECIFICATIONS
GE
R
A
L
D
N
O
R
M
A
N
FI
E
L
D
P
R
O
P
E
R
T
Y
C
L
A
I
M
S
S
P
E
C
I
A
L
I
S
T
NBG
#C 82777
E
Bldg #101123222
APPROVALS:
PLNG - C. Santana
BLDG - A. So
PUBLIC WORKS - Y. Soto
UP
11'-9"10'-2"
13
'
-
1
0
"
1'
-
1
0
"
9'
-
5
"
15
'
-
4
"
17'-11"11'-9"
14
'
-
4
"
5'
-
3
"
5'
-
0
"
5'
-
0
"
2'
-
0
"
10
'
-
4
"
19'-3"
19
'
-
3
"
16
'
-
1
1
"
19'-3"
15
'
-
1
0
"
16'-6"
ROOM
7'-11"10'-7"
16
'
-
1
"
6'
-
1
1
"
ROOM
18
'
-
1
0
"
5'-3"
N/
A
RO
O
M
ROOM
3'-2"
18
'
-
1
0
"
ROOM
ROOM
3'-1"
5'
-
3
"
RO
O
M
RO
O
M
N/
A
RO
O
M
8'-2"
ROOM
ROOM
ROOM
ROOM ROOM ROOM
ROOM
ROOM
10'-2"
GAS METER
LOCATION
(NOT AFFECTED)
ELECTRICAL METER
LOCATION
(NOT AFFECTED)
ELECTRICAL PANEL
LOCATION
(NOT AFFECTED)
D
A
B
B
B
B
B
B
B
C
(E) PATIO
STRUCTURE
LEGEND:
:REFER TO ELECTRICAL DRAWINGS FOR WORK
:WINDOW OPERABLE AS EMERGENCY EXIT
:SLIDING GLASS DOOR
:MAIN ENTRY DOOR
A
B
C
D
NOTES:
1. VERIFY ALL CONDITIONS & DIMENSIONS IN FIELD.
2. OPEN UP WALLS AND CEILING IN EXPECTED AREA OF DAMAGE. WIDEN SEARCH FOR
DAMAGED MEMBERS UNTIL NO MORE DAMAGE IS PRESENT. NOTIFY THE SEOR
IMMEDIATELY OF ANY DAMAGE OR FRAMING DEVIANCE FROM THIS PLAN.
3. PLATE HEIGHT= 8'-0" (VIF)
4. ROOF PITCH= 4:12 (VIF)
SHEET REFERENCE:
SHEET: OF
SHEET INFO:
REVISION DATE:
ME
R
C
U
R
Y
I
N
S
U
R
A
N
C
E
,
I
N
C
.
PR
O
J
E
C
T
:
CL
I
E
N
T
:
CA
H
O
-
0
0
2
5
0
9
9
4
SHEET TITLE:
JE
R
R
Y
N
G
O
JOB NO.
SCALE:
DATE:
DESIGNER: BS
25-0001
01/17/25
DRAFTER: AG
PR
O
P
E
R
T
C
L
A
I
M
S
A
D
J
U
S
T
E
R
10
4
8
I
R
V
I
N
E
A
V
E
N
U
E
,
S
U
I
T
E
1
0
8
7
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
0
PH
O
N
E
:
9
4
9
-
2
5
9
-
6
0
8
0
BR
Y
A
N
@
S
T
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
ST
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
12
2
2
S
O
U
T
H
L
I
N
D
A
W
A
Y
215
S-5
LAYOUT PLAN (1/4" = 1'-0")
ARCHITECTURAL
LAYOUT PLAN
GE
R
A
L
D
N
O
R
M
A
N
FI
E
L
D
P
R
O
P
E
R
T
Y
C
L
A
I
M
S
S
P
E
C
I
A
L
I
S
T
NBG
#C 82777
E
(E) DROP BEAM IN CEILING ABOVE
(E) ATTIC ACCESS
GARAGE
REMOVE
UNPERMITTED SINK
06/11/25
N
31'-4"
4'
5'
24'-10"
33'-6"
36'-1"
48'-8"
54'-4"
S LINDA WAY
PROPERTY LINE
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
SMOKE DAMAGE
OBSERVED AT
ENTRY WAY
(E) INTERIOR W/
EXTENSIVE DAMAGE
THROUGHOUT. NO WOOD
CHARRING OR SEVERE
DISCOLORATION
OBSERVED
SMOKE DAMAGE
OBSERVED AT
SIDE EAVE
SMOKE DAMAGE
OBSERVED AT
SIDE EAVE
SMOKE DAMAGE
OBSERVED AT
SIDE EAVE
SMOKE DAMAGE
OBSERVED AT
DOOR EAVE
(E) UNPERMITTED PATIO
STRUCTURE W/ SEVERE
DISCOLORATION OF
WOOD MEMBERS. PATIO
TO BE REMOVED.
18"
ROOF LINE
SHEET REFERENCE:
SHEET: OF
SHEET INFO:
REVISION DATE:
ME
R
C
U
R
Y
I
N
S
U
R
A
N
C
E
,
I
N
C
.
PR
O
J
E
C
T
:
CL
I
E
N
T
:
CA
H
O
-
0
0
2
5
0
9
9
4
SHEET TITLE:
JE
R
R
Y
N
G
O
JOB NO.
SCALE:
DATE:
DESIGNER: BS
25-0001
01/17/25
DRAFTER: AG
PR
O
P
E
R
T
C
L
A
I
M
S
A
D
J
U
S
T
E
R
10
4
8
I
R
V
I
N
E
A
V
E
N
U
E
,
S
U
I
T
E
1
0
8
7
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
0
PH
O
N
E
:
9
4
9
-
2
5
9
-
6
0
8
0
BR
Y
A
N
@
S
T
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
ST
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
12
2
2
S
O
U
T
H
L
I
N
D
A
W
A
Y
214
S-4
SITE PLAN
SITE PLAN (3/16" = 1'-0")
GE
R
A
L
D
N
O
R
M
A
N
FI
E
L
D
P
R
O
P
E
R
T
Y
C
L
A
I
M
S
S
P
E
C
I
A
L
I
S
T
NBG
#C 82777
E
SHEET REFERENCE:
SHEET: OF
SHEET INFO:
REVISION DATE:
ME
R
C
U
R
Y
I
N
S
U
R
A
N
C
E
,
I
N
C
.
PR
O
J
E
C
T
:
CL
I
E
N
T
:
CA
H
O
-
0
0
2
5
0
9
9
4
SHEET TITLE:
JE
R
R
Y
N
G
O
JOB NO.
SCALE:
DATE:
DESIGNER: BS
25-0001
01/17/25
DRAFTER: AG
PR
O
P
E
R
T
C
L
A
I
M
S
A
D
J
U
S
T
E
R
10
4
8
I
R
V
I
N
E
A
V
E
N
U
E
,
S
U
I
T
E
1
0
8
7
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
0
PH
O
N
E
:
9
4
9
-
2
5
9
-
6
0
8
0
BR
Y
A
N
@
S
T
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
ST
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
12
2
2
S
O
U
T
H
L
I
N
D
A
W
A
Y
212
S-2
SPECIFICATIONS
SHEET 2
WOOD (CONTINUED)GENERAL NOTES (CONTINUED)GENERAL NOTES
1. CONSTRUCTION SHALL CONFORM TO THE PROVISIONS OF THE
CALIFORNIA BUILDING CODE, LATEST EDITION, STANDARDS REFERENCED
THEREIN AND LOCAL JURISDICTION REQUIREMENTS. EXCEPT WHERE
MORE STRINGENT REQUIREMENTS ARE NOTED OR SHOWN IN THE PLANS
OR SPECIFICATIONS, ALL PHASES OF WORKMANSHIP AND MATERIALS
SHALL CONFORM TO THE REQUIREMENTS OF THE LATEST VERSION OF
THE CBC, AS WELL AS ALL APPLICABLE LOCAL ORDINANCES.
2. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL
DIMENSIONS, AND CONDITIONS AT THE JOBSITE, AND TO CROSS CHECK
ALL DETAILS AND DIMENSIONS SHOWN ON THE STRUCTURAL DRAWINGS
WITH RELATED REQUIREMENTS ON THE REST OF THE PROJECT'S
CONSTRUCTION DOCUMENTS PACKAGE AND NOTIFY THE ARCHITECT AND
ENGINEER OF ANY DISCREPANCIES PRIOR TO STARTING WORK. ANY SUCH
DISCREPANCY, OMISSION, OR VARIATION NOT REPORTED SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR.
3. DETAIL MARKED "TYPICAL" SHALL APPLY IN ALL CASES UNLESS
SPECIFICALLY INDICATED OTHERWISE.
4. WHERE NO SPECIFIC DETAIL IS SHOWN, THE FRAMING OR CONSTRUCTION
SHALL BE IDENTICAL OR SIMILAR TO THAT INDICATED FOR LIKE CASES OF
CONSTRUCTION.
5. IN NO CASE SHALL WORKING DIMENSIONS BE SCALED FROM PLANS,
SECTION, OR DETAILS ON THE STRUCTURAL DRAWINGS.
6. PRECISE DIMENSIONS AND LOCATIONS OF ALL BUILDING ELEMENTS SHALL
BE BY OTHERS.
7. THE MEANS AND METHODS PF CONSTRUCTION, INCLUDING THE DESIGN,
ADEQUACY AND SAFETY OF BRACING, SHORING, GUYING, AND ERECTION
AS WELL AS THE SEQUENCE OF CONSTRUCTION HAVE NOT BEEN
CONSIDERED BY THE E.O.R. THE ENGINEER AND HIS REPRESENTATIVES
WILL NOT COVER SUCH ITEMS IN THE COURSE OF THE STRUCTURAL
OBSERVATIONS.
8. VIBRATION ANALYSIS HAS NOT BEEN CONSIDERED BY E.O.R.
9. THE USE OF THESE PLANS, DRAWINGS, SPECIFICATIONS, AND/OR
ELEVATIONS IS RESTRICTED TO THE ORIGINAL USE FOR WHICH THEY
WERE PREPARED AND FURNISHED TO THE CLIENT. PUBLICATION THEREOF
IS EXPRESSLY LIMITED TO SUCH USE. REUSE, REPRODUCTION OR OTHER
PUBLICATION BY ANY METHOD IS PROHIBITED, STREGE STRUCTURAL
ENGINEERING ASSUMES NO LIABILITY FOR THE UNAUTHORIZED USE OF
THESE PLANS.
10. THESE PLANS AND SPECIFICATIONS ARE TO SHOW THE PRIMARY
STRUCTURAL SYSTEM AND ARE SOLELY FOR THE USE OF A BUILDER
KNOWLEDGEABLE AND EXPERIENCES IN THIS TYPE OF WORK.
STRUCTURAL COMPONENTS WHICH ARE NOT A PART OF THE PRIMARY
STRUCTURAL SYSTEM, SUCH AS GLAZING WINDOW WALLS, GUARDRAILS,
TEMPORARY SHORING, MANUFACTURED STRUCTURAL ELEMENTS, SITE
IMPROVEMENTS, PAVING, DRAINAGE STRUCTURES, FREE STANDING
SIGNS AND POLES, AND LANDSCAPE IMPROVEMENTS ARE NOT A PART OF
THIS WORK.
11. ALL WORK OF THE CONTRACTOR, SUB-CONTRACTORS, AND BUILDER
SHALL CONFORM TO CURRENT GOOD PRACTICES.
12. DURING THE COURSE OF CONSTRUCTION, CHANGES MAY OCCUR. THESE
PLANS DO NOT REFLECT THE 'AS-BUILT' PRODUCT.
13. COORDINATE WITH OTHERS DRAWINGS FOR LOCATION AND
CONSTRUCTION OF DRAFT STOPS, FIRE BLOCKING, DAMPERS AND
OTHERS ITEMS NECESSARY FOR FIRE PROTECTION. COORDINATE WITH
OTHERS FOR LOCATION AND CONSTRUCTION OF FLASHING, BLOCKING,
EXTERIOR FINISHES, TREATMENTS OR OTHER MATERIAL REQUIRED FOR
DAMP PROOFING OR MOISTURE CONTROL.
14. FOR ANY PRE-MANUFACTURED PRODUCTS OR MATERIALS OF
CONSTRUCTION, CONTRACTOR SHALL BE RESPONSIBLE FOR BEING
FAMILIAR WITH AND FOR PROPER EXECUTION OF MANUFACTURER'S
INSTRUCTIONS, REQUIREMENTS AND CONDITIONS OF APPROVAL PRIOR
TO INSTALLATION AND/OR USE. THE ACCEPTANCE OF DEFERRED
SUBMITTALS, TESTS AND MATERIALS BY E.O.R. DOES NOT CONSTITUTE
THE APPROVAL BY THE LOCAL JURISDICTION. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO ACQUIRE APPROVAL FROM THE LOCAL JURISDICTION
PRIOR TO START OF WORK.
15. DUE TO LOCATION, SOME STRUCTURAL COMPONENTS ARE REQUIRED BY
CODE TO BE PROTECTED FROM WATER/MOISTURE PENETRATION OR
FROM FIRE DAMAGE. THE METHODS OF PROTECTION OF THESE
STRUCTURAL COMPONENTS ARE NOT THE RESPONSIBILITY OF THE E.O.R.
AND ARE NOT DETAILED IN THESE DRAWINGS. REFER TO OTHERS FOR
WATER/MOISTURE PROOFING METHODS AND FIRE PROOFING DETAILS.
16. THERE SHALL BE NO TRENCHES OR EXCAVATIONS 5 FEET OR MORE IN
DEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND: OR OBTAIN
NECESSARY PERMIT FROM STATE OF CALIFORNIA, DIVISION OF
INDUSTRIAL SAFETY PRIOR TO THE ISSUANCE OF A BUILDING OR GRADING
PERMIT.
17. ANY ASTM DESIGNATIONS SHALL BE AMENDED TO DATE.
18. ALL STEEL STAIRS ARE DESIGN-BUILD UNLESS SPECIFICALLY NOTED AND
DETAILED ON DRAWINGS.
19. DRYWALL STACKING ON WOOD FRAMED BUILDING:
x DRYWALL SHALL NOT BE STACKED MORE THAN 18 SHEETS OR 12 INCHES
VERTICALLY IN ANY ONE STACK UNLESS SHORING IS PROVIDED.
x DRYWALL SHALL BE STACKED FLAT, AND SHALL NOT BE STORED ON END
NOR ON EDGE.
x DRYWALL SHALL NOT BE STACKED ON TOP OF ANY CONSTRUCTION
MATERIAL, EXCEPT THE FLOOR SYSTEM AND DRYWALL SHIMS TO ELEVATE
THE DRYWALL.
x NO OTHER CONSTRUCTION MATERIALS OR EQUIPMENT SHALL BE
STOCKED, STORED, OR STACKED ON TOP OF DRYWALL STACKS.
x ANY FLOOR SYSTEM EXPOSED TO MOISTURE SHALL NOT BE USED TO
SUPPORT DRYWALL STACKS.
x THE EOR MUST BE NOTIFIED IF:
xx THE WALL FINISH MATERIAL IS OTHER THAN DRYWALL, ALSO KNOWN
AS SHEETROCK AND GYPSUM BOARD.
xx THE WALL FINISH MATERIAL WEIGHS MORE THAN 2.2 PSF.
xx THE WALL FINISH MATERIAL IS GREATER THAN 5/8" THICK.
20. GENERAL NOTES AND NOTES ON THESE SHEETS SHALL APPLY UNLESS
SPECIFICALLY SHOWN OR NOTED OTHERWISE. CONSTRUCTION DETAILS
NOT FULLY SHOWN OR NOTED SHALL BE SIMILAR TO DETAILS SHOWN FOR
SIMILAR CONDITIONS. ALL WORK OR CONSTRUCTION SHALL COMPLY WITH
ALL APPLICABLE BUILDING CODES, REGULATION AND SAFETY
REQUIREMENTS.
21. SHORING: IT SHALL BE THE CONTRACTOR'S SOLE RESPONSIBILITY TO
DESIGN AND PROVIDE ADEQUATE SHORING, BRACING, AND FORM WORK,
AS REQUIRED FOR THE PROTECTION OF LIFE AND PROPERTY DURING THE
CONSTRUCTION OF THIS BUILDING. SHORING PLAN SHOWING METHOD &
TIMING OF SHORING, DESHORING AND RESHORING MUST BE PREPARED
BY A LICENSED ENGINEER. SHORING PLAN MUST BE SUBMITTED TO THE
ENGINEER'S OFFICE FOR REVIEW PRIOR TO START OF WORK.
22. EXCAVATION: THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR
ALL EXCAVATION PROCEDURE INCLUDING LAGGING, SHORING, AND
PROTECTION OF ADJACENT PROPERTY, STRUCTURES, STREETS AND
UTILITIES IN ACCORDANCE WITH THE REQUIREMENT OF LOCAL
JURISDICTION.
23. OTHER TRADES: SEE THE REST OF THE PROJECT'S CONSTRUCTION
DOCUMENTS PACKAGE FOR SIZE AND LOCATION OF PIPE, VENT, DUCT
AND OTHER OPENINGS AND DETAILS NOT SHOWN ON THESE STRUCTURAL
DRAWINGS. ALL ITEMS IN THE PLANS INDICATED BY OTHERS ARE NOT
REVIEWED, INSPECTED, OR OBSERVED BY SSE. COORDINATE
REQUIREMENTS WITH THE APPROPRIATE PARTY.
24. BACK FILL: BACK FILL OF BUILDING RETAINING WALL SHALL NOT BE
PLACED UNTIL AFTER THE WALLS ARE SUPPORTED BY THE COMPLETION
OF INTERIOR FLOOR SYSTEMS. DO NOT PROCEED WITH BACK FILL UNTIL
SEVEN (7) DAYS AS A MINIMUM AFTER THE COMPLETION OF INTERIOR
FLOOR SYSTEMS UNLESS WALLS ARE ADEQUATELY BRACED. BACKFILL
PLACED IMMEDIATELY BEHIND RETAINING WALLS SHALL BE COMPACTED
WITH HAND OPERATED EQUIPMENT.
25. WELDING: ALL WELDING SHALL BE PERFORMED BY WELDERS CERTIFIED
FOR THE WELDS TO BE MADE; SEE SPECIFICATIONS FOR WELDING
PROCESS TO BE USED. WELDING OF REINFORCING STEEL FOR USE IN
STRUCTURAL CONCRETE OR STRUCTURAL MASONRY SHALL BE
PERMITTED ONLY WHERE SPECIFICALLY DESIGNATED ON THESE PLANS
OR WHERE SPECIFICALLY INDICATED BY THE ENGINEER.
26. SIDEWALK PROTECTION: PEDESTRIAN TRAFFIC SHALL BE PROTECTED PER
THE REQUIREMENT OF CODE AND LOCAL JURISDICTION.
27. SAFETY: THE CONTRACTOR SHALL ADEQUATELY PROTECT HIS WORK,
ADJACENT PROPERTY, AND THE PUBLIC, AND BE RESPONSIBLE FOR
DAMAGE OR INJURY DUE TO HIS ACT OR NEGLECT.
28. MATERIALS AND WORKMANSHIP WARRANTY: THE CONTRACTOR SHALL
REPLACE ANY DEFECTIVE MATERIALS AND CORRECT POOR
WORKMANSHIP WITH NO ADDITIONAL COSTS TO THE OWNER, AND SHALL
REMEDY ANY DEFECTS IN MATERIAL OR WORKMANSHIP WHICH APPEAR IN
2 YEARS FROM THE DATE OF COMPLETION OF THE JOB. THIS WARRANTY
APPLIES TO THE WORK DONE BY THE SUBCONTRACTORS AS WELL AS THE
WORK DONE BY THE EMPLOYEES OF THE CONTRACTOR.
29. WHERE THERE IS CONFLICTING STRUCTURAL DESIGN INFO SHOWN ON
STRUCTURAL PLANS, DETAILS, OR SCHEDULES, THE MORE RESTRICTIVE
REQUIREMENT SHALL CONTROL.
WOOD
WOOD (CONTINUED)
1. ALL LUMBER USED FOR STRUCTURAL PURPOSES SHALL BE DOUGLAS
FIR-LARCH, COAST REGION, GRADED IN ACCORDANCE WITH THE WEST
COAST LUMBER INSPECTION BUREAU THAT COMPLIES WITH PRODUCT
STANDARD DOC PS 20 OR EQUIVALENT. ALL LUMBER SHALL BE LESS
THAN 19% MOISTURE CONTENT FOR ALL CONSTRUCTION. CONTRACTOR
SHALL TEST AND MANAGE MOISTURE CONTENT TO ENSURE PROPER
MOISTURE CONTENT DURING ALL STORAGE AND HANDLING
OPERATIONS.
2. THE MINIMUM GRADES SHALL BE AS FOLLOWS UNLESS NOTED
OTHERWISE ON PLANS.
GRADES FOR HORIZONTAL FRAMING MEMBERS SHALL BE AS FOLLOWS
UNLESS NOTED OTHERWISE ON PLANS:
x 2X D.F.#2
x 4X12 OR SMALLER D.F.#2
x 4X14 OR LARGER D.F.#1
x 6X D.F.#1
x 8X D.F.#1
GRADES FOR VERTICAL FRAMING MEMBERS (STUDS AND POSTS) SHALL
BE AS FOLLOWS UNLESS NOTED OTHERWISE ON PLANS:
x 2X4 D.F.#2
x 4X6 D.F.#2
x 3X4 & 3X6 D.F.#2
x 4X4 & 4X6 D.F.#2
x 6X6 OR LARGER D.F.#1
GRADES FOR MISCELLANEOUS FRAMING MEMBERS:
x 2X4 & 3X SILL PLATE P.T. D.F. STANDARD GRADE
x 3X &2X TOP PLATE/SOLE PLATE D.F. STANDARD GRADE
x SHEAR BLOCKING D.F. STANDARD GRADE
GRADE FOR NON-STRUCTURAL FRAMING MEMBERS:
x BLOCKING & BRIDGING UTILITY GRADE
NOTE:
x ALL BLOCKING SHALL BE CUT TO FIT FLUSH AGAINST SHEATHING AND
THE ADJOINING FRAMING MEMBERS.
x STUDS AT NON-BEARING WALL MAY BE STANDARD OR STUD GRADE.
3. ALL SILL PLATES BEARING ON MASONRY OR CONCRETE FOUNDATION
WALL OR SLAB ON GRADE SHALL BE PRESSURE-TREATED IN
ACCORDANCE WITH CBC 2304.12. SILL PLATES SHALL BE BOLTED TO THE
FOUNDATION WITH 5/8" DIAMETER BOLTS AT 4'-0" O.C. MAXIMUM U.N.O.
ON S.W. SCHEDULE EMBEDDED 7 INCH MINIMUM CONCRETE. ALL BOLTS
SHALL HAVE WASHERS AND NUTS PER SHEAR WALL SCHEDULE.
MINIMUM 2 BOLTS PER PLATE. ONE BOLT WITHIN 12 INCHED OF PLATE
END AND CORNERS.
4. WALL FRAMING SHALL BE PER SCHEDULE SHOWN ON FRAMING PLANS.
U.N.O. ON SCHEDULE, MINIMUM WALL FRAMING TO BE 2X STUDS AT 16
INCHES O.C. ON EXTERIOR WALLS AND 2X STUDS AT 16 INCHED O.C. AT
INTERIOR WALLS. PROVIDE DOUBLE TOP PLATE ON ALL WALLS WITH
MINIMUM 48 INCH LAP SPLICE U.N.O. UNLESS SPECIFICALLY NOTED ON
PLANS. THE MAXIMUM STUD HEIGHT FOR 2X4 EXTERIOR WALL IS 10 FEET,
FOR 2X4 INTERIOR WALL IS 14 FEET. MAXIMUM NON-BEARING STUD
HEIGHT FOR 2X6 STUDS IS 20 FEET U.N.O.
5. PROVIDE 0.058"X1-1/2" WIDE STEEL TIE STRAPS WITH 6-16D NAILS AT
EACH SIDE WHERE PLATES ARE INTERRUPTED BY UTILITY
PENETRATIONS @ NON-SHEAR WALLS. IF PENETRATIONS OCCUR AT
SHEAR WALL, NOTIFY THE ENGINEER PRIOR TO STARTING WORK.
6. PROVIDE A SINGLE JOIST UNDER NON-BEARING PARTITION PARALLEL TO
JOISTS.PROVIDE MINIMUM 2 FLOOR JOISTS BELOW BEARING WALLS
UNLESS NOTED OTHERWISE ON PLANS.
7. ROOF SHEATHING SHALL BE INSPECTED PRIOR TO PLACING INSULATION
AND ROOFING.
8. ALL STRUCTURAL SHEATHING SHALL BE IDENTIFIED WITH THE GRADE
TRADEMARK OF APA - THE ENGINEERED WOOD ASSOCIATION. THE
SHEATHING SHALL MEET THE REQUIREMENTS OF PRODUCT STANDARD
DOC PS 1-09 AND DOC PS 2-10 OR ANSI/APA PRP-210. INSTALL SHEATHING
PANEL WITH STRENGTH AXIS OR FACE GRAIN PERPENDICULAR TO
FRAMING SUPPORTS AND WITH PANEL CONTINUOUS OVER TWO OR MORE
SPANS. PANELS WITH DIMENSION LESS THAN 24 INCHES IN ANY
DIRECTION SHALL NOT BE USED UNLESS ALL EDGES ARE BLOCKED WITH
MIN. 2X FRAMING MEMBERS. PANELS INSTALLED AT LOCATIONS
PERMANENTLY EXPOSED TO WEATHER SHALL BE GRADED WITH
EXTERIOR EXPOSURE.
ROOF SHEATHING:
x THICKNESS: 15/32" RATED SHEATHING (MIN.) VERIFY W/ ARCHITECT
x EXPOSURE: EXPOSURE 1
x PANEL INDEX: 24/0
x NAILING: 8D COMMON @ 6" O.C. AT SUPPORTED EDGES
8D COMMON @ 12" O.C. AT INTERMEDIATE SUPPORTS
x BLOCKING UNBLOCKED U.N.O. ON PLANS. SEE ARCH. PLANS FOR
ADDITIONAL REQUIREMENTS AT FLAT ROOF.
FLOOR SHEATHING:
x THICKNESS: T&G, 23/32", RATED STURD-I-FLOOR (T&G)
x EXPOSURE: EXPOSURE 1
x PANEL INDEX: 24 oc
x NAILING: 10D COMMON @ 6" O.C. AT SUPPORTED EDGES
10D COMMON @ 12" O.C. AT INTERMEDIATE SUPPORTS
x BLOCKING UNBLOCKED U.N.O. ON PLANS.
EXTERIOR DECK SHEATHING:
x THICKNESS: T&G, 23/32" MIN. (1-1/8" MAX), RATED CD EXTERIOR
(NO O.S.B.)
x EXPOSURE: EXTERIOR EXPOSURE
x PANEL INDEX: 48/24
x NAILING: 10D COMMON @ 6" O.C. AT SUPPORTED EDGES
10D COMMON @ 12" O.C. AT INTERMEDIATE SUPPORTS
x BLOCKING UNBLOCKED U.N.O. ON PLANS.
EXTERIOR SUNDECK SHEATHING BELOW PAVER:
x THICKNESS: T&G, 1-1/8", RATED CD EXTERIOR (NO O.S.B.)
x EXPOSURE: EXTERIOR EXPOSURE
x PANEL INDEX: 48/24
x NAILING: 10D COMMON @ 6" O.C. AT SUPPORTED EDGES
10D COMMON @ 12" O.C. AT INTERMEDIATE SUPPORTS
x BLOCKING UNBLOCKED U.N.O. ON PLANS.
SHEAR PANEL:
x THICKNESS: PER SHEAR WALL SCHEDULE
x EXPOSURE: EXPOSURE 1
x PANEL INDEX: 24/0
x NAILING: PER SHEAR WALL SCHEDULE
x BLOCKING BLOCKED
*SPECIAL INSPECTION BY A DEPUTY INSPECTOR IS NOT REQUIRED
WHERE THE FASTENER SPACING OF THE SHEATHING IS GREATER THAN 4
INCHES ON CENTER.
9. FLOOR JOISTS ARE NOT DESIGNED TO SUPPORT WATER BEDS. EOR TO
BE NOTIFIED IF WATER BEDS ARE TO BE USED.
10. STRUCTURAL MEMBERS SHALL NOT BE CUT OR NOTCHED UNLESS
SPECIFICALLY DETAILED BY THE EOR.
11. ALL BEAMS TO BE SUPPORTED WITH FULL BEARING MULTI-STUD OR POST,
U.N.O.
12. FRAMING FOR PREFABRICATED FIREPLACE FLUES SHALL BE BALLOON
FRAMED FULL HEIGHT USING 2X4 STUDS AT 16" O.C. BRACED AT
MID-HEIGHT AND AT THE PLATE HEIGHTS. MAXIMUM UNBRACED LENGTH
IS 14'-0".
13. INTERIOR NON-BEARING HEADERS MAY BE 2X4 FLAT. INSTALL 4X4 AT 6'
AND 8' CLOSET DOORS.
14. PRESERVATIVE-TREATED WOOD CANNOT BE ENCLOSED OR COVERED IF
OVER 19% MOISTURE CONTENT. CONTRACTOR TO ENSURE PROPER
MOISTURE CONTENT.
15. NAILS SHALL BE DRIVEN FLUSH TO SHEATHING AND NOT OVERDRIVEN.
16. WOOD FRAMING MEMBERS (INCLUDING WOOD SHEATHING) LESS THAN 8
INCHES FROM EXPOSED EARTH SHALL BE NATURALLY DURABLE OR
PRESERVATIVE-TREATED WOOD.
17. FASTENERS FOR PRESSURE-PRESERVATIVE-TREATED AND
FIRE-RETARDANT-TREATED WOOD SHALL BE OF HOT-DIPPED ZINC
COATED GALVANIZED WITH COATING WEIGHT PER ASTM A-153 OR
STAINLESS STEEL. EXEMPTION: PROVIDE A LETTER FROM THE
MANUFACTURER OF THE TREATED WOOD PRODUCT STATING THAT
CORROSION RESISTANT FASTENERS ARE NOT REQUIRED.
18. HOLES DRILLED IN WOOD MEMBERS FOR ANCHOR BOLTS AND MACHINE
BOLTS SHALL BE 1/32" MINIMUM AND 1/16" MAXIMUM LARGER THAN THE
BOLT DIAMETER.
19. ALL LUMBER AND PLYWOOD AT EXTERIOR WALLS OF TYPE III
CONSTRUCTION OR WHERE NOTED BY ARCHITECT SHALL BE
FIRE-RETARDANT TREATED WOOD AND SHALL CONFORM TO 2016 CBC
2302.2. THE MAXIMUM REDUCTION OF ALLOWABLE STRESSES OF FIRE
RETARDANT TREATED WOOD SHALL BE PER TABLE BELOW. PRODUCT
WITH ICC-ES REPORT MUST BE SUBMITTED TO EOR FOR REVIEW.
DESIGN PARAMETERS
COMPRESSION PARALLEL, Fc
HORIZONTAL SHEAR, Fv
TENSION PARALLEL, Ft
MAX REDUCTION
FACTOR
MAX REDUCTION
FACTOR
MODULUS OF ELASTICITY, E
BENDING, Fb
STRUCT. SHEATHING: ALL
STRESSES & SPAN RATING
0.10
0.05
0.15
0.03
0.10
0.16
ENGINEERED WOOD FRAMING MEMBERS
1. (TJI, MICROLLAM, PARALLAM, TIMBERSTRAND) PREFABRICATED FLOOR
FRAMING STRUCTURAL MEMBERS ARE MANUFACTURED BY
WEYERHAUSER. THESE PRODUCTS ARE APPROVED BY ICC (ESR 1153 &
ESR 1387).
2. STRUCTURAL COMPOSITE LUMBER
PRODUCT
PARALLAM PSL 2.2E
MICROLLAM LVL 2.0E
TIMBERSTRAND LSL 1.55E
E (KSI)
2200
2000
1550
Fb (PSI)
2900
2600
2325
Fv (PSI)
290
285
310
3. USE SIMPSON STRONG-TIE IUS SERIES HANGER FOR TJI CONNECTION TO
SUPPORTING FLUSH BEAM, U.N.O.
4. PRODUCT HANDLING, INSTALLATION PROCEDURES, SHALL BE STRICTLY IN
ACCORDANCE WITH THE "SPECIFIER'S GUIDE" PUBLISHED BY TRUSS
JOIST CO.
PREFABRICATED WOOD ROOF AND WOOD FLOOR TRUSSES
1. SEE FRAMING PLANS FOR FRAMING DIRECTIONS AND BEARING LOCATIONS.
2. TRUSS SHOP DWGS MUST BE DESIGNED TO WORK AS A SYSTEM. DESIGN
TO BE PERFORMED AND LAYOUTS AND CALCULATION TO BE SEALED BY A
REGISTERED ENGINEER LICENSED IN THE APPLICABLE STATE. PER CBC
2303.4.1.4.
3. EACH PREFABRICATED TRUSS SHALL BE LEGIBLY BRANDED, MARKED OR
OTHERWISE HAVE PERMANENTLY AFFIXED THERETO THE FOLLOWING
INFORMATION LOCATED WITHIN 2 FEET OF THE CENTER OF SPAN ON THE FACE
OF THE BOTTOM CHORD:
a. IDENTITY OF THE COMPANY MANUFACTURING THE TRUSS
b. BEARING LOCATION
c. THE SPACING OF THE TRUSSES
4. APPROVED CONNECTOR PLATES SHALL BE AT LEAST 20 GAUGE
GALVANIZED STEEL PER ASTM A-446. ALL CONNECTORS AND SPIKE-GRID
PLATES SHALL HAVE A CURRENT ICC OR ESR NUMBER.
5. ANY FIELD REPAIR TO THE TRUSS SHALL BE PERFORMED UNDER THE
DIRECTION OF THE TRUSS SUPPLIER'S ENGINEER.
6. ROOF TRUSSES SHALL BE DESIGNED FOR THE FOLLOWING LOADS:
DL = 10PSF AT TOP CHORD, 10 PSF AT BOTTOM CHORD (EOR TO BE
NOTIFIED IF WEIGHT OF FLAT ROOFING MATERIAL EXCEEDS 6 PSF)
LL = 20 PSF AT TOP CHORD, 10 PSF AT BOTTOM CHORD
(NON-CONCURRENT WITH TOP CHORD LL)
FLOOR TRUSSES SHALL BE DESIGNED FOR THE FOLLOWING LOADS:
DL = 25 PSF
LL = 40 PSF
7. FLOOR TRUSSES SHALL BE DESIGNED FOR A LIVE LOAD DEFLECTION NOT
GREATER THAN L/720.
8. TRUSS CALCULATIONS AND PLANS SHALL INCLUDE REVIEW OF ROOF,
MECHANICAL, AND LATERAL LOADS (CHORD/STRUT AND BRACE LOADS);
ALSO INCLUDE REVIEW OF TOP AND BOTTOM CHORD FOR AXIAL +
FLEXURE BETWEEN PANEL JOINTS. VERIFY EQUIPMENT PAD LOADS AND
ANY CONCENTRATED LOADS FROM PURLIN/KICKERS AT CONVENTIONAL
ROOF.
9. ROOF TRUSSES WITH 42" OR MORE CLEAR HEIGHT SHALL BE DESIGNED
FOR 20 PSF STORAGE LOAD PER CBC 1607.1.
10. CORNICE EXTENSION ON PARAPETS, WHERE DETAILED BY ARCHITECT,
SHALL BE DESIGNED FOR 60 PSF.
11. PROVIDE 2X4 LADDER BLOCKING AT 24" O.C. WHERE SPREAD TRUSSES
OCCUR. (4' MAX.)
12. PROVIDE 2X BLOCKING WITH BOUNDARY NAILING AT ROOF RIDGE, TYP.
13. ALL END TRUSSES SHALL BE DESIGNED FOR A 180 PLF LOAD APPLIED TO
THE TOP CHORD. ALSO, END TRUSSES SHALL HAVE WEBS CAPABLE OF
WITHSTANDING 25 PSF WIND LOADS APPLIED OUT-OF-PLANE.
WOOD GLUE-LAMINATED LUMBER (GLB)
1. STRUCTURAL GLUE-LAMINATED LUMBERS SHALL BE FABRICATED BY A LOS
ANGELES CITY BUILDING DEPARTMENT LICENSED SHOP AND IN
ACCORDANCE WITH ANSI A190.1 AND APA-WS117 OR AITC 117.
2. INDIVIDUAL LAMINATIONS SHALL NOT EXCEED 2 INCHES IN NET THICKNESS.
3. MOISTURE CONTENT SHALL BE FROM 7% TO 12%.
4. ALL GLB SHALL BE DELIVERED TO JOBSITE WITH AITC CERTIFICATES. AITC
CERTIFICATE SHALL BE PROVIDED TO THE BLDG. INSPECTOR PRIOR TO
INSTALLATION.
5. PROVIDE TENSION LAMINATION AT BOTTOM OF BEAMS AND AT TOP OF
CONTINUOUS BEAMS OVER SUPPORTS, UNLESS NOTED OTHERWISE.
6. CAMBER - STANDARD, UNLESS NOTED ON PLANS.
7. LAMINATED BEAMS SHALL BE APA-EWS. DOUGLAS FIR GLB & PROVIDE
STRESS VALUES THAT MEET OR EXCEED THE REQUIREMENTS FOR EWS
24F-V4 DF/DF (24F-V8 DF/DF FOR CONTINUOUS BEAM OVER SUPPORTS)
COMBINATION.
FLEXURAL STRESS Fb=2,400 PSI
TENSION PARALLEL TO GRAIN Ft=1,100 PSI
COMPRESSION PARALLEL TO GRAIN Fc=1,650 PSI
HORIZ. SHEAR PERPENDICULAR TO WIDE FACE Fv=265 PSI
MODULUS OF ELASTICITY E=1800 KSI
COMPRESSION PERPENDICULAR TO GRAIN:
TENSION FACE Fc=650 PSI
COMPRESSION FACE Fc=650 PSI
8. ENDS OF BEAMS SHALL BE SEALED AND BEAMS SHALL BE WRAPPED FOR
PROTECTION PRIOR TO CONSTRUCTION. HANDLING & STORING OF GLBS
TO CONFORM TO AITC 111-2005.
9. ALL GLB EXPOSED TO WEATHER OR MOISTURE SHALL BE FACTORY
PRESSURE TREATED.
10. IDENTIFY GRADE SYMBOL AND LAMINATION SPECIES PER TABLE 5A, 2015
NDS SUPPLEMENT.
NAIL DEFINITIONS
USE COMMON NAILS UNLESS INDICATED OTHERWISE ON THE PLANS.
DESIGNATION DIAMETER LENGTH
16D COMMON 0.162 3.1/2"
16D SINKER 0.148 3.1/4"
16D SHORT 0.162 2.1/2"
8D COMMON 0.131 2.1/2"
10D COMMON 0.148 3"
GE
R
A
L
D
N
O
R
M
A
N
FI
E
L
D
P
R
O
P
E
R
T
Y
C
L
A
I
M
S
S
P
E
C
I
A
L
I
S
T
NBG
#C 82777
E
SHEET REFERENCE:
SHEET: OF
SHEET INFO:
REVISION DATE:
ME
R
C
U
R
Y
I
N
S
U
R
A
N
C
E
,
I
N
C
.
PR
O
J
E
C
T
:
CL
I
E
N
T
:
CA
H
O
-
0
0
2
5
0
9
9
4
SHEET TITLE:
JE
R
R
Y
N
G
O
JOB NO.
SCALE:
DATE:
DESIGNER: BS
25-0001
01/17/25
DRAFTER: AG
PR
O
P
E
R
T
C
L
A
I
M
S
A
D
J
U
S
T
E
R
10
4
8
I
R
V
I
N
E
A
V
E
N
U
E
,
S
U
I
T
E
1
0
8
7
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
0
PH
O
N
E
:
9
4
9
-
2
5
9
-
6
0
8
0
BR
Y
A
N
@
S
T
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
ST
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
12
2
2
S
O
U
T
H
L
I
N
D
A
W
A
Y
213
S-3
SPECIFICATIONS
SHEET 3
CONCRETE
REINFORCEMENT
WOOD (CONTINUED)
WOOD FRAMING CONNECTORS
1. ALL WOOD FRAMING CONNECTORS SHALL BE SIMPSON "STRONG-TIE" OR
MITEK/USP (OR EQUIVALENT). INSTALLATION PROCEDURES AHALL BE IN
ACCORDANCE WITH MANUFACTURED PRODUCT AND CURRENT
INSTRUCTION MANUAL/CATALOG.
CONNECTOR CODE REPORT REFERENCE:
SIMPSON PRODUCT MITEK.USP PRODUCT SUBSTITION
ITEM ICC-ES IAPMO LARR- ITEMESR-IAPMO LARR-ESR-
ICC-ES
A35/LTP4 2606 - 25716 MPA1/MP_F 3455 - 25745
LTP5 - ER-112 25814 MP_F 3455 - 25745
CBSQ - - - - - -LEGACY
ER-5952
CCQ/ECCQ/AC/ACE
CMST/CMSTC/CS/ST/
MST/MSTA
HTT
IUS
MASA
PA/HPA/PAI/MPAI
U/HU/HUC
HUCQ
HDU/HDQ/HHDQ
SDS
SSTB
PB
PC
2604
2330
-
2552
2555
2604
2236
2611
2549
2552
2105
LEGACY
ER-5708
LEGACY
NER-443
-
-
-
-
-
ER-130
-
-
-
-
-
-
-
25713
-
-
25714
25720
25818
25801
25851
25714
25711
25827
25807
25801
KCCQ/KECCQ/PBS/PBES
PHDA/PHD/UPHD
HTT
THF MAX
FA4
CMST/CMSTC/RS/ST/
KST/MSTA
PCM
WS
STB
SUH/HD/HDIF
3449
3455
3847
3445
2787
3449
2761
2266
3445
-
ER-0200
-
-
-
-
-
-
-
-
-
25779
25954
26048
25843
26017
25779
25850
25992
25843
25745
2. MINIMUM NAILING TO CONNECT WOOD MEMBERS SHALL BE AS
SPECIFIED IN CBC TABLE 2304.10.1.
3. PLATE NAILING FROM BLOCKING TO WALL TOP PLATE SHALL BE 16D
COMMON AT 8 INCHES ON-CENTER MAXIMUM UNLESS NOTED
OTHERWISE ON SHEAR WALL SCHEDULE.
4. A COPY OF THE JURISDICTION RESEARCH REPORT AND/OR CONDITIONS
OF LISTING, IF ANY SHALL BE MADE AVAILABLE AT THE JOB SITE.
5. SOLE PLATE NAILING FROM WALL SOLE PLATE TO JOIST OR BLOCKING
BELOW SHALL BE 16D COMMON AT 8 INCHES ON-CENTER MAXIMUM
UNLESS NOTED OTHERWISE ON SHEAR WALL SCHEDULE.
6. DEPUTY INSPECTION IS REQUIRED FOR ALL HOLD DOWN ANCHOR BOLTS.
7. ALL HOLD DOWN ANCHOR NUTS SHALL BE TIGHTENED JUST PRIOR TO
COVERING WALL FRAMING. (LEAVE ENOUGH SPACE BETWEEN THE SILL
AND THE HD TO ALLOW FOR SOME SLIP AT POST CONNECTION WHEN
TIGHTENING). HOLD DOWN CONNECTOR BOLTS INTO WOOD FRAMING
REQUIRE APPROVED PLATE WASHER THAT IS IN ACCORDANCE WITH THE
LOCAL JURISDICTION.
8. FOR LAG BOLTS: PROVIDE LEAD HOLES 40% TO 70% OF SHANK DIA. AND
FULL DIA, FOR SHANK PORTION. SOAP, PARAFFIN, OR OTHER APPROVED
LUBRICANT SHALL BE USED ON THREADS. INSTALLATION SHALL BE BY
SCREWING, NO HAMMERING. CARE SHALL BE TAKEN TO AVOID OVER
TORQUING OF THE BOLT.
9. ALL MULTI-STUDS ARE TO BE LAMINATED WITH 16D AT 8" O.C.
10. ALL BALLOON FRAMED WALLS SHALL BE BRACED TO CONFORM TO CBC
TABLE 2308.5.1.
11. PROVIDE PRE-DRILLING WHERE NECESSARY TO AVOID SPLITTING.
12. ONLY COMMON NAILS SHALL BE USED FOR ALL WOOD SHEAR WALLS
AND SHEAR TRANSFER CONNECTIONS. NAIL GUNS USING "CLIPPED
HEADS" OR "SINKER" NAILS ARE NOT ACCEPTABLE.
13. PROVIDE MINIMUM OF 1/2" EDGE DISTANCE FOR ALL PLYWOOD
BOUNDARY NAILING IN SHEAR WALLS, ALL PLYWOOD EDGES SHALL BE
BLOCKED. MIN. WIDTH OF BLOCKING TO RECEIVE PLYWOOD NAILING
MUST NOT BE LESS THAN THE THICKNESS OF BOUNDARY MEMBER AS
SPECIFIED ON SHEAR WALL SCHEDULE.
14. OMIT SHEATHING B.N. UNDER CMST STRAP. INSTALL CMST OVER
SHEATHING, U.N.O.
15. TOE NAILING SHALL NOT BE USED IN A SHEAR CONNECTION.
16. HOLD DOWN ANCHORS MUST BE TIED IN PLACE PRIOR TO FOUNDATION
INSPECTION.
STRUCTURAL STEEL & METAL
1. ALL STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED IN
ACCORDANCE WITH THE LATEST AISC SPECIFICATIONS AND THE CODE
OF STANDARD PRACTICE. LICENSED FABRICATORS SHALL BE APPROVED
BY THE JURISDICTION.
2. ALL STEEL EXCEPT PIPE, TUBE & W ASTM A-36
PIPE ASTM A-53, TYPE E / S, GRADE B
ROUND HSS ASTM A-500, GRADE B
RECTANGULAR HSS ASTM A-500, GRADE B
W-SHAPE ASTM A-992
3. BOLTS
x HIGH STRENGTH BOLTS ASTM A325
x ALL OTHER BOLTS ASTM A307
4. THREADED RODS
x HIGH STRENGTH RODS ASTM A193 GR. B7 OR A449
x ALL OTHER RODS ASTM A36
5. ANCHOR RODS
x HIGH STRENGTH ASTM A193 GR. B7 OR ASTM A449
x ALL OTHER RODS ASTM A307 OR ASTM F1554 GR.36
6. BOLT HOLES
x MINIMUM EDGE DISTANCE AISC TABLE J3.5
x MINIMUM SPACING 3 BOLT DIAMETER
x HIGH STRENGTH BOLTS FRICTION TYPE W/ CLASS A
FAYING SURFACE
7. MINIMUM FILLET WELD AISC TABLE J2.4
8. ALL FIELD WELDING TO BE CONTINUOUSLY INSPECTED BY A SPECIAL
INSPECTOR QUALIFIED IN WELDING. FIELD WELDERS MUST BE
APPROVED BY THE JURISDICTION.
9. ALL SHOP WELDS SHALL BE PERFORMED BY A LICENSED FABRICATOR'S
SHOP APPROVED BY THE JURISDICTION.
10. ALL UNEXPOSED STEEL STEEL STRUCTURES PAINTING
COUNCIL SPECIFICATION 15-687
11. EXPOSED STEEL GALVANIZED
12. EXPANSION BOLTS (RED HEAD) ICC RESEARCH
RECOMMENDATION #1821
13. SELF-DRILLING ANCHORS ICC RESEARCH
RECOMMENDATION #1372
14. POWDER ACTUATED FASTENERS 0.145" DIAM. PER ICC-ES
ESR-2379 (COLA RR#25708)
(HILTI OR APPROVED EQ.)
0.157" DIAM. PER ICC-ES
ESR-2269 (COLA RR#25675)
(HILTI OR APPROVED EQ.)
15. ALL WALLS SHALL HAVE FASTENERS PLACED AT 6" FROM ENDS OF SILL
PLATES. INSTALL PER ICC REPORT REQUIREMENTS & MANUFACTURER'S
RECOMMENDATIONS.
16. LIGHT GAGE COLD-FORMED STEEL MEMBERS SHALL CONFORM TO
ASTM-A-441, U.N.O.
17. WHERE HIGH-STRENGTH (H.S.) BOLTS ARE SPECIFIED ON THE PLANS,
THEY SHALL BE FRICTION TYPE CONFORMING TO ASTM A 325 (SC) WITH A
CLASS A FAYING SURFACE. THERE SHALL BE NO PAINT, OIL, LACQUER OR
GALVANIZING ON THE CONTACT SURFACES.
18. ALL GROUT UNDER STEEL BEARING PLATES SHALL BE SOLID DRYPACK
OR NON-SHRINK GROUT. F'c=4,000 PSI.
19. METAL FLOOR DECK: FLOOR:PLN (CATALOG VF2-P.90)
ROOF:PLN-24 (CATALOG VR1-P.29)
MFR. BY VERCO MANUFACTURING CO.
(ASTM A-653, LARR #23789)
STRUCTURAL STEEL & METAL (CONTINUED)
CONCRETE QUALITY: SHALL BE AS SHOWN BELOW:
CONCRETE USE (MIN.)
-
STRENGTH
(KSI) AT 28
DAYS
SLUMP W/C RATIO
(MAX.)
FLY ASH
(% MAX.)
MAX
AGGREGATE
MAX.
SHRINKAGE
%
- - - - - -
GENERAL NOTES:
*USE f 'c=4500 PSI TYPE V CONCRETE WITH WATER CEMENT RATIO=0.45 IF
CONCRETE IS PLACED IN EXPOSURE CLASS S2 OR S3
**SHRINKAGE CHARACTERISTIC SHALL MEET OR EXCEED SLAB LEVEL MIX
DESIGN.
CONCRETE WEIGHT: ALL CONCRETE SHALL BE REGULAR WEIGHT OF 145
POUNDS PER CUBIC FOOT UNLESS NOTED OTHERWISE. MAXIMUM IN-PLACE
DENSITY OF NON-STRUCT. LIGHTWEIGHT CONCRETE FLOOR TOPPING IS TO BE
100#/CU.FT.
AGGREGATE: SIZE OF AGGREGATE SHALL CONFORM TO ASTM C33-85
3/4" ASTM SIZE #67
1" ASTM SIZE #57
1.1/2" ASTM SIZE #4
CEMENT: PORTLAND CEMENT SHALL CONFORM TO ASTM C150 TYPE II, U.N.O.
CONCRETE AGE: NO MORE THAN 90 MINUTES SHALL ELAPSE BETWEEN
CONCRETE BATCHING AND CONCRETE PLACEMENT UNLESS APPROVED BY
TESTING AGENCY.
WET SET: REINFORCEMENT MAY NOT BE WET SET IN CONCRETE POURS.
INSERTS: ALL ITEMS TO BE CAST IN CONCRETE SUCH AS REINFORCING,
DOWELS, BOLTS, ANCHORS, PIPES, SLEEVES, ETC., SHALL BE SECURELY
POSITIONED IN THE FORMS BEFORE PLACING OF CONCRETE.
ROUGHENED SURFACES: WHERE INDICATED ON THE DRAWINGS, ROUGHENED
SURFACES SHALL BE PROVIDED BY MEANS OF HEAVY RAKING OR GROOVING.
OTHER METHODS MAY BE ACCEPTABLE PENDING WRITTEN DIRECTION BY THE
ENGINEER. ALL INTERFACING SURFACES MUST BE CLEAN AND FREE OF LOOSE
MATERIALS.
ADMIXTURES: NO ADMIXTURES SHALL BE ADDED TO THE CONCRETE MIX
WITHOUT THE WRITTEN DIRECTION OF THE ENGINEER, UNLESS NOTED
OTHERWISE.
CHLORIDES: GROUT OR CONCRETE CONTAINING CHLORIDES SHALL NOT BE
USED.
DEBRIS: REMOVE ALL DEBRIS FROM FORMS BEFORE POURING.
SEGREGATION OF AGGREGATES: CONCRETE SHALL NOT BE DROPPED
THROUGH REINFORCING STEEL (AS IN WALLS, COLUMNS AND DROP CAPITALS)
SO AS TO CAUSE SEGREGATION OF AGGREGATES. USE HOPPERS, CHUTES OR
TRUNKS OF VARYING LENGTH SO THAT THE FREE UNCONFINED FALL OF
CONCRETE SHALL NOT EXCEED SIX FEET, AND A SUFFICIENT NUMBER SHALL
BE USED TO ENSURE THAT THE CONCRETE IS KEPT LEVEL AT ALL TIMES.
CONSTRUCTION JOINTS: THE CONTRACTOR SHALL OBTAIN THE ENGINEER'S
APPROVAL OF CONSTRUCTION JOINT LOCATION IN SLABS AND BEAMS.
SPLICES: SPLICE BARS IN MEMBERS SUCH AS SPANDRELS, BEAMS, ETC., AS
FOLLOWS: TOP BARS AT CENTERLINE OF SPAN, BOTTOM BARS AT THE
SUPPORT. ALL REINFORCING STEEL SHALL BE SECURELY WIRED AND
PROPERLY SUPPORTED ABOVE GROUND AND AWAY FROM THE FORMS. DRAG
REINF TO HAVE TYPE II MECH CONNECTOR, U.N.O. ON PLANS.
TEMPERATURE AND SHRINKAGE REINFORCEMENT: SHALL HAVE A LAP OF
THIRTY (30) BAR DIAMETERS, BUT NOT LESS THAN 18 INCHES, AND THE
SPLICES IN ADJACENT BARS SHALL BE OFFSET NOT LESS THAN FIVE (5) FEET
APART.
REBAR GRADES: ALL REINFORCING STEEL SHALL BE NEW STOCK DEFORMED
BARS CONFORMING TO ASTM A615 AS FOLLOWS:
#3 & SMALLER BARS GRADE 40, U.N.O.
#4 & LARGER BARS GRADE 60, U.N.O.
REBAR COVER: MINIMUM REBAR COVER FOR CONCRETE SHALL BE AS SHOWN
IN THIS TABLE, U.N.O.
REINFORCEMENT (CONTINUED)
TOLERANCE (±)MINUMUM
COVEREXPOSURE CONDITION
CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3.0 3/8"
EXPOSED TO EARTH OR WEATHER:
NO. 5 AND SMALLER BARS
NO. 6 AND LARGER BARS
1.1/2"
2"
1/4"
1/4"
NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND:
ROOF SLAB
STRUCTURAL SLABS & WALLS
STRUCTURAL SLABS (RATED ASSEMBLY)
MID SPAN
END SPAN
BEAMS AND COLUMNS (COVER TO TIES, STIRRUPS & SPIRALS)
SLAB ON GRADE 1.1/2" 1/4"
1"
1"
SEE SLAB
NOTES
1.1/2"
1/8"
1/8"
1/8"
1/8"
1/8"
1/8"
TOLERANCES FOR LONGITUDINAL LOCATION OF BENDS AND ENDS OF
REINFORCEMENT SHALL BE ± TWO (2) INCHES, EXCEPT AT DISCONTINUOUS
ENDS OF MEMBERS WHERE TOLERANCES SHALL BE ± 1/2 INCH.
STRUCTURAL OBSERVATION
1. WHEN REQUIRED BY THE CODE, OWNER OR THE OWNER'S AUTHORIZED
AGENT SHALL EMPLOY A REGISTERED DESIGN PROFESSIONAL TO
PERFORM STRUCTURAL OBSERVATIONS AS DEFINED IN CBC SECTION
1702 AND 1704.6.
2. STRUCTURAL OBSERVER SHALL PERFORM VISUAL OBSERVATION OF THE
STRUCTURAL SYSTEM AT SIGNIFICANT CONSTRUCTION STAGES AND AT
COMPLETION OF THE STRUCTURAL SYSTEM.
3. AT THE CONCLUSION OF THE WORK INCLUDED IN THE PERMIT, THE
STRUCTURAL OBSERVER SHALL SUBMIT TO THE BUILDING OFFICIAL A
WRITTEN STATEMENT THAT THE SITE VISITS HAVE BEEN MADE AND
IDENTIFY ANY REPORTED DEFICIENCIES THAT, TO THE BEST OF THE
STRUCTURAL OBSERVER'S KNOWLEDGE, HAVE NOT BEEN RESOLVED.
4. STRUCTURAL OBSERVATION PROGRAM
WOOD CONSTRUCTION - PRIOR TO COVERING TO WOOD FRAMING,
REPRESENTATIVE SECTIONS OF THE FOLLOWING ARES TO BE
OBSERVED:
x CONCRETE EMBEDS SUCH AS HOLD DOWN ANCHORS AND ANCHOR
BOLTS
x SHEAR WALL
x HOLD DOWN CONNECTIONS BETWEEN FLOORS
x BLOCKED FLOOR/ROOF DIAPHRAGM NAILING
CONCRETE AND MASONRY CONSTRUCTION - PRIOR TO CONCRETE
PLACEMENT, REPRESENTATIVE SECTIONS OF THE FOLLOWING AREAS TO
BE OBSERVED:
x GRADE BEAM AND ITS REINFORCEMENT
x CONCRETE/MASONRY SHEAR WALL REINFORCEMENT
x P.T. LAYOUT/SLAB REINFORCEMENT
SPECIAL INSPECTION
1. REFER TO SECTION 1702 OF BUILDING CODE FOR DEFINITION OF WORDS
AND TERMS.
2. OWNER'S RESPONSIBILITY
THE OWNER AND THE OWNER'S AUTHORIZED AGENT, OTHER THAN
THE CONTRACTOR (THE CONTRACTOR IS PERMITTED WHERE THE
CONTRACTOR IS ALSO THE OWNER), SHALL EMPLOY ONE OR MORE
APPROVED AGENCIES TO PROVIDE SPECIAL INSPECTIONS AND
TESTS DURING CONSTRUCTION ON THE TYPES OF WORK
SPECIFIED BELOW AND IDENTIFY THE APPROVED AGENCIES TO
THE BUILDING OFFICIAL.
3. CONTRACTOR'S RESPONSIBILITY
a. NOTIFY THE SPECIAL INSPECTOR IN ADVANCE FOR INDIVIDUAL
INSPECTIONS FOR ITEMS SPECIFIED ON THE APPROVED PLAN AND
ITEMS LISTED IN SECTIONS 1704 AND 1705.
b. RETAIN SPECIAL INSPECTION RECORDS AT JOB SITE AND PROVIDE
THESE RECORDS FOR REVIEW BY THE BUILDING DEPARTMENT
INSPECTOR UPON REQUEST.
c. SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY IN
ACCORDANCE WITH THE REQUIREMENTS SPECIFIED IN SECTION
1704.4, TO THE BUILDING OFFICIAL AND THE OWNER OR THE
OWNER AUTHORIZED AGENT PRIOR TO THE COMMENCEMENT OF
WORK. THE CONTRACTOR'S STATEMENT OF RESPONSIBILITY
SHALL CONTAIN ACKNOWLEDGEMENT OF AWARENESS OF THE
SPECIAL REQUIREMENTS CONTAINED IN THE STATEMENT OF
SPECIAL INSPECTIONS AND THE MINIMUM REQUIREMENT
SPECIFIED IN CBC CHAPTER 17.
4. APPROVED AGENCY'S RESPONSIBILITY
a. PERFORM ON-SITE PERIODIC AND CONTINUOUS INSPECTIONS FOR
CONFORMANCE WITH THE BUILDING DEPARTMENT APPROVED
PLANS AND PER THE REQUIREMENT SPECIFIED IN SECTION 1704
AND 1705.
b. PERFORM PERIODIC AND CONTINUOUS INSPECTION FOR OFFSITE
FABRICATION OF STRUCTURAL MEMBERS.
EXCEPTION: SPECIAL INSPECTIONS ARE NOT REQUIRED FOR
OFF-SITE FABRICATION WORK PERFORMED ON PREMISES OF
A FABRICATOR REGISTERED AND APPROVED TO PERFORM
SUCH WORK WITHOUT SPECIAL INSPECTION.
c. MAINTAIN SPECIAL INSPECTION AND TEST RECORDS AND FURNISH
RECORDS TO CONTRACTOR, OWNER AND DESIGN PROFESSIONAL
IN RESPONSIBLE CHARGE.
d. BRING DISCREPANCIES TO THE IMMEDIATE ATTENTION OF THE
CONTRACTOR FOR CORRECTIONS. IF NOT CORRECTED IN A TIMELY
MANNER, BRING TO THE ATTENTION OF THE BUILDING OFFICIAL
AND THE DESIGN PROFESSIONALS PRIOR TO THE COMPLETION OF
THAT PHASE OF THE WORK.
e. A FINAL REPORT DOCUMENTING REQUIRED SPECIAL INSPECTIONS
AND TESTS, AND CORRECTIONS OF ANY DISCREPANCIES NOTED IN
THE INSPECTIONS OR TESTS, SHALL BE SUBMITTED AT A POINT IN
TIME AGREED UPON PRIOR TO THE START OF WORK BY THE
OWNER OR THE OWNER'S AUTHORIZED AGENT TO THE BUILDING
OFFICIAL.
5. THE FOLLOWING WORK/ITEMS, IF CHECKED, MUST BE INSPECTED/
VERIFIED BY THE APPROVED AGENCIES TO ENSURE THAT THE
WORKMANSHIP AND QUALITY OF WORK/ITEMS IS A CONFORMANCE WITH
THE DESIGN INTENT AND THE CORRESPONDING REFERENCED
STANDARD LISTED IN CHAPTER 17 OF THE BUILDING CODE.
CONCRETE CONSTRUCTION
TYPE SPECIAL
CONTINUOUS
INSPECTION
SPECIAL
PERIODIC
INSPECTION
INSPECT REINFORCEMENT, INCLUDING PRESTRESSING
TENDONS, AND VERIFY PLACEMENT X
REINFORCING BAR WELDING
x VERIFY WELDABILITY OF REINFORCING BARS OTHER THAN
ASTM A706
x INSPECT SINGLE-PASS FILLET WELDS, MAXIMUM 5/16"
x INSPECT ALL OTHER WELDS
X
X
X
INSPECT ANCHORS CAST IN CONCRETE
INSPECT ANCHORS POST-INSTALLED IN HARDENED CONCRETE
MEMBERS:
x ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR
UPWARDLY INCLINED ORIENTATIONS TO RESIST SUSTAINED
TENSION LOADS
x MECHANICAL ANCHORS AND ADHESIVE ANCHORS NOT
DEFINED AS ABOVE.
X
X
VERIFY USE OF REQUIRED DESIGN MIX X
PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS FOR
STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS,
AND DETERMINE THE TEMPERATURE OF THE CONCRETE.
X
INSPECT CONCRETE AND/OR SHOTCRETE PLACEMENT FOR
PROPER APPLICATION TECHNIQUES.X
VERIFY MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND
TECHNIQUES.X
INSPECT PRE-STRESSED CONCRETE FOR:
x APPLICATION OF PRESTRESSING FORCES
x GROUTING OF BONDED PRESTRESSING TENDONS
X
X
VERIFY IN-SITU CONCRETE STRENGTH, PRIOR TO STRESSING OF
TENDONS IN POST-TENSIONED CONCRETE AND PRIOR TO
REMOVAL OF SHORES AND FORMS FROM BEAMS AND
STRUCTURAL SLABS.
INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF
THE CONCRETE MEMBER BEING FORMED.
X
X
SPECIAL INSPECTION (CONTINUED)
SOILS INSPECTION
TYPE SPECIAL
CONTINUOUS
INSPECTION
SPECIAL
PERIODIC
INSPECTION
XVERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE
TO ACHIEVE THE DESIGN BEARING CAPACITY
XVERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE
REACHED PROPER MATERIAL
PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL
MATERIALS X
VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT
THICKNESSES DURING PLACEMENT AND COMPACTION OF
COMPACTED FILL
PRIOR TO PLACEMENT OF COMPACTED FILL, INSPECT SUBGRADE
AND VERIFY THAT SITE HAS BEEN PREPARED PROPERLY X
X
WOOD FRAMING
TYPE SPECIAL
CONTINUOUS
INSPECTION
SPECIAL
PERIODIC
INSPECTION
(*) NAILING, BOLTING, ANCHOR AND OTHER FASTENING OF:
XxSHEAR WALL
XxBLOCKED FLOOR AND ROOF DIAPHRAGM
XxDRAG STRUT
XxSEISMIC BRACE
XxSHEAR PANEL
XxHOLD DOWN ASSEMBLY
X
HIGH LOAD DIAPHRAGM
x INSPECT THE WOOD STRUCTURAL PANEL SHEATHING TO
ASCERTAIN WHETHER GRADE AND THICKNESS IS AS SHOWN ON
APPROVED CONSTRUCTION DOCUMENTS.
x VERIFY THE NOMINAL SIZE OF FRAMING MEMBERS AT
ADJOINING PANEL EDGES, NAIL DIAMETER AND LENGTH, THE
NUMBER OF FASTENER LINES AND THAT THE SPACING
BETWEEN FASTENERS IN EACH LINE AND AT EDGE MARGINS
AGREES WITH THE APPROVED CONSTRUCTION DOCUMENTS.
(*) SPECIAL INSPECTIONS ARE NOT REQUIRED WHERE THE FASTENER SPACING OF THE SHEATHING IS
MORE THAN 4 INCHES ON CENTER.
(*) SPECIAL INSPECTIONS ARE NOT REQUIRED FOR THE SEISMIC FORCE-RESISTING SYSTEMS OF
STRUCTURES ASSIGNED TO SEISMIC DESIGN CATEGORY A OR B.
OTHER COMPONENTS
TYPE SPECIAL
CONTINUOUS
INSPECTION
SPECIAL
PERIODIC
INSPECTION
(**) ARCHITECTURAL COMPONENTS (INSTALLED 30' ABOVE GRADE
PLANE) ERECTION AND FASTENING OF:
XxEXTERIOR CADDING (IF > 5 PSF)
XxVENEER (IF > 5 PSF)
XxNON BEARING WALL (IF > 15 PSF)
MECHANICAL COMPONENTS - SEE MECHANICAL DRAWINGS AND
SPECS.
ELECTRICAL COMPONENT - SEE ELECTRICAL DRAWINGS AND SPECS.
(**) SPECIAL INSPECTIONS ARE NOT REQUIRED FOR THE SEISMIC FORCE-RESISTING SYSTEMS OF
STRUCTURES ASSIGNED TO SEISMIC DESIGN CATEGORY A, B, OR C.
GE
R
A
L
D
N
O
R
M
A
N
FI
E
L
D
P
R
O
P
E
R
T
Y
C
L
A
I
M
S
S
P
E
C
I
A
L
I
S
T
NBG
#C 82777
E
UP
(E) GARAGE
FOOTING
(E) GARAGE
FOOTING
(E) CRAWL
SPACE ACCESS
PANEL
(E) FJ (E) FJ (E) FJ
(E) FJ(E) FJ(E) FJ(E) FJ(E) FJ
(E
)
F
L
O
O
R
B
E
A
M
L
I
N
E
(E) FLR
POST/FOOTING
PAD
(E) FOUNDATION
TYP.
NOTE: NO DAMAGE OBSERVED TO EXISTING
FOUNDATION OR FLOOR SYSTEM.
SHEET REFERENCE:
SHEET: OF
SHEET INFO:
REVISION DATE:
ME
R
C
U
R
Y
I
N
S
U
R
A
N
C
E
,
I
N
C
.
PR
O
J
E
C
T
:
CL
I
E
N
T
:
CA
H
O
-
0
0
2
5
0
9
9
4
SHEET TITLE:
JE
R
R
Y
N
G
O
JOB NO.
SCALE:
DATE:
DESIGNER: BS
25-0001
01/17/25
DRAFTER: AG
PR
O
P
E
R
T
C
L
A
I
M
S
A
D
J
U
S
T
E
R
10
4
8
I
R
V
I
N
E
A
V
E
N
U
E
,
S
U
I
T
E
1
0
8
7
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
0
PH
O
N
E
:
9
4
9
-
2
5
9
-
6
0
8
0
BR
Y
A
N
@
S
T
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
ST
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
12
2
2
S
O
U
T
H
L
I
N
D
A
W
A
Y
216
S-6
STRUCTURAL
FOUNDATION/ FLOOR
STRUCTURAL FOUNDATION/ FLOOR FRAMING PLAN (1/4" = 1'-0")
FRAMING PLAN
GE
R
A
L
D
N
O
R
M
A
N
FI
E
L
D
P
R
O
P
E
R
T
Y
C
L
A
I
M
S
S
P
E
C
I
A
L
I
S
T
NBG
#C 82777
E
(E) GARAGE HDR
(E) HDR
(E) HDR
(E
)
H
D
R
(E
)
H
D
R
(E) HDR
(E) HDR
(E) HDR
(E) HDR
(E
)
H
D
R
(E
)
H
D
R
(E) HDR
(E
)
H
D
R
(E
)
H
D
R
(E
)
H
D
R
(E
)
H
D
R
(E
)
H
D
R
(E
)
H
D
R
(E
)
H
D
R
(E) HDR
(E) BM
(E
)
H
D
R
(E
)
H
D
R
(E) PILASTER W/
WOOD POST
INSIDE (REMOVE)
TYP.
(E
)
B
M
(E) BM (REMOVE)
(E) BM
(E) BM (REMOVE)
18" (TYP.)
(E
)
R
O
O
F
F
R
A
M
I
N
G
(E)
H
I
P
B
E
A
M
(E) ROOF FRAMING
(E)
H
I
P
B
E
A
M
(E) ROOF FRAMING
(E) ROOF FRAMING(E) ROOF FRAMING
(E)
V
A
L
L
E
Y
B
E
A
M
(E)
H
I
P
B
E
A
M
(E) CEILING FRAMING
(E) ROOF FRAMING
(E) CEILING FRAMING
(E) ROOF FRAMING
(E
)
R
O
O
F
FR
A
M
I
N
G
#
S-#(E
)
R
O
O
F
F
R
A
M
I
N
G
DA
M
A
G
E
D
B
Y
R
O
O
F
C
U
T
S
(E) BM (VIF)
CLEAN RAFTER
ENDS & BM & VIF
(E
)
P
A
T
I
O
S
H
E
D
RO
O
F
J
O
I
S
T
S
(R
E
M
O
V
E
)
(E
)
P
A
T
I
O
S
H
E
D
RO
O
F
J
O
I
S
T
S
(R
E
M
O
V
E
)
(E) CEILING FRAMING
(E)
H
I
P
B
E
A
M
(E)
H
I
P
B
E
A
M
(E
)
R
O
O
F
F
R
A
M
I
N
G
(
V
I
F
)
(E
)
R
O
O
F
F
R
A
M
I
N
G
(E
)
R
O
O
F
F
R
A
M
I
N
G
(E
)
C
E
I
L
I
N
G
F
R
A
M
I
N
G
(E) ROOF FRAMING
(E
)
C
E
I
L
I
N
G
F
R
A
M
I
N
G
(E
)
C
E
I
L
I
N
G
F
R
A
M
I
N
G
(E
)
C
E
I
L
I
N
G
F
R
A
M
I
N
G
(E
)
R
O
O
F
F
R
A
M
I
N
G
(E) ROOF
FRAMING
(E) ROOF
FRAMING
(E)
V
A
L
L
E
Y
B
E
A
M
(E) BM
NOTE: MINIMAL STRUCTURAL DAMAGE TO EXISTING
WALL AND ROOF MEMBERS. ONLY DAMAGE OBSERVED
TO MAIN HOUSE WAS DUE TO FIRE CUTS MADE IN
PUTTING THE FIRE OUT. EXISTING ROOF SYSTEM TO
REMAIN. EXISTING LATERAL FORCE RESISTING SYSTEM
TO REMAIN. EXISTING ROOF DIAPHRAGM TO REMAIN.
EXISTING PATIO STRUCTURE TO BE REMOVED.
SHEET REFERENCE:
SHEET: OF
SHEET INFO:
REVISION DATE:
ME
R
C
U
R
Y
I
N
S
U
R
A
N
C
E
,
I
N
C
.
PR
O
J
E
C
T
:
CL
I
E
N
T
:
CA
H
O
-
0
0
2
5
0
9
9
4
SHEET TITLE:
JE
R
R
Y
N
G
O
JOB NO.
SCALE:
DATE:
DESIGNER: BS
25-0001
01/17/25
DRAFTER: AG
PR
O
P
E
R
T
C
L
A
I
M
S
A
D
J
U
S
T
E
R
10
4
8
I
R
V
I
N
E
A
V
E
N
U
E
,
S
U
I
T
E
1
0
8
7
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
0
PH
O
N
E
:
9
4
9
-
2
5
9
-
6
0
8
0
BR
Y
A
N
@
S
T
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
ST
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
12
2
2
S
O
U
T
H
L
I
N
D
A
W
A
Y
217
S-7
STRUCTURAL ROOF
FRAMING PLAN
STRUCTURAL ROOF FRAMING PLAN (1/4" = 1'-0")
GE
R
A
L
D
N
O
R
M
A
N
FI
E
L
D
P
R
O
P
E
R
T
Y
C
L
A
I
M
S
S
P
E
C
I
A
L
I
S
T
NBG
#C 82777
E
SHEET REFERENCE:
SHEET: OF
SHEET INFO:
REVISION DATE:
ME
R
C
U
R
Y
I
N
S
U
R
A
N
C
E
,
I
N
C
.
PR
O
J
E
C
T
:
CL
I
E
N
T
:
CA
H
O
-
0
0
2
5
0
9
9
4
SHEET TITLE:
JE
R
R
Y
N
G
O
JOB NO.
SCALE:
DATE:
DESIGNER: BS
25-0001
01/17/25
DRAFTER: AG
PR
O
P
E
R
T
C
L
A
I
M
S
A
D
J
U
S
T
E
R
10
4
8
I
R
V
I
N
E
A
V
E
N
U
E
,
S
U
I
T
E
1
0
8
7
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
0
PH
O
N
E
:
9
4
9
-
2
5
9
-
6
0
8
0
BR
Y
A
N
@
S
T
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
ST
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
12
2
2
S
O
U
T
H
L
I
N
D
A
W
A
Y
218
S-8
STRUCTURAL DETAILS
SHEET 1
GE
R
A
L
D
N
O
R
M
A
N
FI
E
L
D
P
R
O
P
E
R
T
Y
C
L
A
I
M
S
S
P
E
C
I
A
L
I
S
T
13INTERSECTION & CORNERS (N.T.S.)
DETAIL (N.T.S.)STANDARD HOOKS (N.T.S.)20 4
18REINFORCEMENT DEVELOPMENT LENGTH (N.T.S.)2(E) GARAGE FOOTING DETAIL (N.T.S.)
DETAIL (N.T.S.)12
1014DETAIL (N.T.S.)DETAIL (N.T.S.)
1115DETAIL (N.T.S.)
16 DETAIL (N.T.S.)
DETAIL (N.T.S.)
9DETAIL (N.T.S.)
7DETAIL (N.T.S.)
(E) INTERIOR FOOTING DETAIL (N.T.S.)8
(E) PERIMETER FOOTING DETAIL (N.T.S.)6
(E) FOOTING &
STEM WALL
(E) PRESSURE
TREATED SILL (NO
DAMAGE / NO
CHANGE)
(E) WALL (NO
DAMAGE / NO
CHANGE)
(E) SHEAR TRANSFER
(NO DAMAGE / NO
CHANGE)
NOTE: NO DAMAGE OBSERVED IN
FLOOR OR FOUNDATION. DETAIL
SHOWN FOR CLARITY ONLY.
(E) ANCHOR BOLTS (NO
DAMAGE / NO CHANGE)
(E) SHT'G. / FRM'G. (NO
DAMAGE / NO CHANGE)
(E) FOOTING /
REIN. (NO CHANGE
/ NO DAMAGE)
(E) FJ & BLK'G. (NO
DAMAGE / NO
CHANGE)
NOTE: NO DAMAGE OBSERVED IN
FLOOR OR FOUNDATION. DETAIL
SHOWN FOR CLARITY ONLY.
(E) SHT'G. / FRM'G. (NO
DAMAGE / NO CHANGE)
(E) FLR. FRM'G. /
FOOTING (NO DAMAGE /
NO CHANGE)
(E) GARAGE WALL PER
PLAN (NO DAMAGE / NO
CHANGE)
(E) GARAGE FOOTING /
SLAB ON GRADE (NO
DAMAGE / NO CHANGE)
(E) CONC.
FLATWORK
WHERE
OCCURS
NOTE: NO DAMAGE OBSERVED IN
FLOOR OR FOUNDATION. DETAIL
SHOWN FOR CLARITY ONLY.
NBG
#C 82777
E
SHEET REFERENCE:
SHEET: OF
SHEET INFO:
REVISION DATE:
ME
R
C
U
R
Y
I
N
S
U
R
A
N
C
E
,
I
N
C
.
PR
O
J
E
C
T
:
CL
I
E
N
T
:
CA
H
O
-
0
0
2
5
0
9
9
4
SHEET TITLE:
JE
R
R
Y
N
G
O
JOB NO.
SCALE:
DATE:
DESIGNER: BS
25-0001
01/17/25
DRAFTER: AG
PR
O
P
E
R
T
C
L
A
I
M
S
A
D
J
U
S
T
E
R
10
4
8
I
R
V
I
N
E
A
V
E
N
U
E
,
S
U
I
T
E
1
0
8
7
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
0
PH
O
N
E
:
9
4
9
-
2
5
9
-
6
0
8
0
BR
Y
A
N
@
S
T
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
ST
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
12
2
2
S
O
U
T
H
L
I
N
D
A
W
A
Y
219
S-9
STRUCTURAL DETAILS
SHEET 2
GE
R
A
L
D
N
O
R
M
A
N
FI
E
L
D
P
R
O
P
E
R
T
Y
C
L
A
I
M
S
S
P
E
C
I
A
L
I
S
T
DETAIL (N.T.S.)
WALL OPENING FRAMING (N.T.S.)ALLOWABLE PENETRATIONS (N.T.S.)20 4
DETAIL (N.T.S.)11
DETAIL (N.T.S.)16
2
3(N) ROOF SHEATHING PATCH DETAIL (N.T.S.)
1JOIST TO WALL DETAIL (N.T.S.)
JOIST TO RIDGE BOARD DETAIL (N.T.S.)6DETAIL (N.T.S.)
9DETAIL (N.T.S.)13DETAIL (N.T.S.)
DETAIL (N.T.S.)1014
12 (N) ROOF SHEATHING PATCH DETAIL (N.T.S.)
5DETAIL (N.T.S.)
(E) WALL
(N) JOIST AS REQ'D.
W/ A35 @ EA. END
REMOVE / REPLACE (E)
BLK'G. & BN AS REQ'D.
REPLACE ANY / ALL SHEAR
TRANSFER AS REQ'D.
(E) / (N) SHT'G. AS
REQ'D.
(E) EAVE / FRM'G.
WEHRE OCCURS
NOTCH (N) JOISTS
AS REQ'D. DO NOT
OVER-NOTCH.
ROOF SHT'G.
SANDWITCH
DAMAGED JOIST W/
(2)2X (MATCH
DEPTH). STAGGER
(3)#10 WS EA. SIDE
(Lmin = 3")
A35 EA. END /
EA. SIDE
RIDGE BOARD
(E) JOIST (VIF)
(E) 1X STRAIGHT
SLAT SHT'G. (VIF)
(N) 3/4" THK. RATED
ROOF SHT'G.
(MATCH (E) THK.)
(N) 3X JOIST @ SHT'G.
ROOF CUT
(E) FIRE CUT
(N) SIMP. WSV200 @ 6" O.C.(N) SIMP. WSV200
@ 6" O.C.
(N) SIMP.
WSV200 @ 6"
O.C.
(N) SIMP. WSV200
@ 6" O.C.
(N) 2X JOIST
@ 24" O.C.(E) JOIST (VIF)
(N) 3X JOIST @ SHT'G.
ROOF CUT
(E) JOIST
BEHIND (VIF)
(E) 1X STRAIGHT
SLAT SHT'G. (VIF)
(N) 3/4" THK. RATED
ROOF SHT'G.
(MATCH (E) THK.)
(N) 3X BLK'G. @ SHT'G.
ROOF CUT (A35 EA. SIDE
/ EA. END TO JOIST)
(E) FIRE CUT
(N) SIMP. WSV200 @ 6" O.C.(N) SIMP. WSV200
@ 6" O.C.
(N) SIMP.
WSV200 @ 6"
O.C.
(N) SIMP. WSV200
@ 6" O.C.
(N) 3X BLK'G. @ SHT'G.
ROOF CUT (A35 EA. SIDE
/ EA. END TO JOIST)
NBG
#C 82777
E
ELECTRICAL ABBREVIATIONS ELECTRICAL LIGHTING LEGEND ELECTRICAL POWER LEGENDELECTRICAL GENERAL NOTES
SERVICE INSTALLATION NOTES
LIGHTING FIXTURE SCHEDULE
FIRE ALARM LEGEND
NOT TO SCALE
WALL PENETRATION DETAIL
TYPICAL CONDUIT GYPSUM21VERTICAL CONDUIT
PENETRATION DETAIL
NOT TO SCALE
SHEET REFERENCE:
SHEET: OF
SHEET INFO:
REVISION DATE:
ME
R
C
U
R
Y
I
N
S
U
R
A
N
C
E
,
I
N
C
.
PR
O
J
E
C
T
:
CL
I
E
N
T
:
CA
H
O
-
0
0
2
5
0
9
9
4
SHEET TITLE:
JE
R
R
Y
N
G
O
JOB NO.
SCALE:
DATE:
DESIGNER: BS
25-0001
01/17/25
DRAFTER: AG
PR
O
P
E
R
T
C
L
A
I
M
S
A
D
J
U
S
T
E
R
10
4
8
I
R
V
I
N
E
A
V
E
N
U
E
,
S
U
I
T
E
1
0
8
7
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
0
PH
O
N
E
:
9
4
9
-
2
5
9
-
6
0
8
0
BR
Y
A
N
@
S
T
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
ST
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
12
2
2
S
O
U
T
H
L
I
N
D
A
W
A
Y
2114
E-1
ELECTRICAL
NOTES, LEGENDS
AND SCHEDULES
GE
R
A
L
D
N
O
R
M
A
N
FI
E
L
D
P
R
O
P
E
R
T
Y
C
L
A
I
M
S
S
P
E
C
I
A
L
I
S
T
NBG
#C 82777
E
UP
ROOM
ROOM
RO
O
M
ROOM
ROOM
ROOM
RO
O
M
RO
O
M
RO
O
M
ROOM
ROOM
ROOM
ROOM
ROOM ROOM
ROOM
ROOM
ELECTRICAL LIGHTING NOTES
ELECTRICAL KEYNOTES
SHEET REFERENCE:
SHEET: OF
SHEET INFO:
REVISION DATE:
ME
R
C
U
R
Y
I
N
S
U
R
A
N
C
E
,
I
N
C
.
PR
O
J
E
C
T
:
CL
I
E
N
T
:
CA
H
O
-
0
0
2
5
0
9
9
4
SHEET TITLE:
JE
R
R
Y
N
G
O
JOB NO.
SCALE:
DATE:
DESIGNER: BS
25-0001
01/17/25
DRAFTER: AG
PR
O
P
E
R
T
C
L
A
I
M
S
A
D
J
U
S
T
E
R
10
4
8
I
R
V
I
N
E
A
V
E
N
U
E
,
S
U
I
T
E
1
0
8
7
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
0
PH
O
N
E
:
9
4
9
-
2
5
9
-
6
0
8
0
BR
Y
A
N
@
S
T
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
ST
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
12
2
2
S
O
U
T
H
L
I
N
D
A
W
A
Y
2115
E-2
ELECTRICAL
LIGHTING PLAN
ELECTRICAL LIGHTING PLAN (1/4" = 1'-0")
GE
R
A
L
D
N
O
R
M
A
N
FI
E
L
D
P
R
O
P
E
R
T
Y
C
L
A
I
M
S
S
P
E
C
I
A
L
I
S
T
NBG
#C 82777
E
UP
ROOM
ROOM
RO
O
M
ROOM
ROOM
ROOM
RO
O
M
RO
O
M
RO
O
M
ROOM
ROOM
ROOM
ROOM
ROOM ROOM
ROOM
ROOM
ELECTRICAL NOTES
ELECTRICAL KEYNOTES
SHEET REFERENCE:
SHEET: OF
SHEET INFO:
REVISION DATE:
ME
R
C
U
R
Y
I
N
S
U
R
A
N
C
E
,
I
N
C
.
PR
O
J
E
C
T
:
CL
I
E
N
T
:
CA
H
O
-
0
0
2
5
0
9
9
4
SHEET TITLE:
JE
R
R
Y
N
G
O
JOB NO.
SCALE:
DATE:
DESIGNER: BS
25-0001
01/17/25
DRAFTER: AG
PR
O
P
E
R
T
C
L
A
I
M
S
A
D
J
U
S
T
E
R
10
4
8
I
R
V
I
N
E
A
V
E
N
U
E
,
S
U
I
T
E
1
0
8
7
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
0
PH
O
N
E
:
9
4
9
-
2
5
9
-
6
0
8
0
BR
Y
A
N
@
S
T
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
ST
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
12
2
2
S
O
U
T
H
L
I
N
D
A
W
A
Y
2116
E-3
ELECTRICAL
POWER PLAN
ELECTRICAL POWER PLAN (1/4" = 1'-0")
GE
R
A
L
D
N
O
R
M
A
N
FI
E
L
D
P
R
O
P
E
R
T
Y
C
L
A
I
M
S
S
P
E
C
I
A
L
I
S
T
NBG
#C 82777
E
ELECTRICAL SPECIFICATIONS
SHEET REFERENCE:
SHEET: OF
SHEET INFO:
REVISION DATE:
ME
R
C
U
R
Y
I
N
S
U
R
A
N
C
E
,
I
N
C
.
PR
O
J
E
C
T
:
CL
I
E
N
T
:
CA
H
O
-
0
0
2
5
0
9
9
4
SHEET TITLE:
JE
R
R
Y
N
G
O
JOB NO.
SCALE:
DATE:
DESIGNER: BS
25-0001
01/17/25
DRAFTER: AG
PR
O
P
E
R
T
C
L
A
I
M
S
A
D
J
U
S
T
E
R
10
4
8
I
R
V
I
N
E
A
V
E
N
U
E
,
S
U
I
T
E
1
0
8
7
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
0
PH
O
N
E
:
9
4
9
-
2
5
9
-
6
0
8
0
BR
Y
A
N
@
S
T
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
ST
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
12
2
2
S
O
U
T
H
L
I
N
D
A
W
A
Y
2117
E-4
SPECIFICATIONS
ELECTRICAL
GE
R
A
L
D
N
O
R
M
A
N
FI
E
L
D
P
R
O
P
E
R
T
Y
C
L
A
I
M
S
S
P
E
C
I
A
L
I
S
T
NBG
#C 82777
E
SYMBOL LIST
MECHANICAL ABBREVIATIONSGENERAL NOTESDEMOLITION NOTES MECHANICAL DUCTWORK
SHEET REFERENCE:
SHEET: OF
SHEET INFO:
REVISION DATE:
ME
R
C
U
R
Y
I
N
S
U
R
A
N
C
E
,
I
N
C
.
PR
O
J
E
C
T
:
CL
I
E
N
T
:
CA
H
O
-
0
0
2
5
0
9
9
4
SHEET TITLE:
JE
R
R
Y
N
G
O
JOB NO.
SCALE:
DATE:
DESIGNER: BS
25-0001
01/17/25
DRAFTER: AG
PR
O
P
E
R
T
C
L
A
I
M
S
A
D
J
U
S
T
E
R
10
4
8
I
R
V
I
N
E
A
V
E
N
U
E
,
S
U
I
T
E
1
0
8
7
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
0
PH
O
N
E
:
9
4
9
-
2
5
9
-
6
0
8
0
BR
Y
A
N
@
S
T
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
ST
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
12
2
2
S
O
U
T
H
L
I
N
D
A
W
A
Y
2110
M-1
MECHANICAL
NOTES AND LEGENDS
GE
R
A
L
D
N
O
R
M
A
N
FI
E
L
D
P
R
O
P
E
R
T
Y
C
L
A
I
M
S
S
P
E
C
I
A
L
I
S
T
NBG
#C 82777
E
UP
ROOM
ROOM
RO
O
M
ROOM
ROOM
ROOM
RO
O
M
RO
O
M
RO
O
M
ROOM
ROOM
ROOM
ROOM ROOM ROOM
ROOM
ROOM
MECHANICAL PLAN NOTES
SHEET REFERENCE:
SHEET: OF
SHEET INFO:
REVISION DATE:
ME
R
C
U
R
Y
I
N
S
U
R
A
N
C
E
,
I
N
C
.
PR
O
J
E
C
T
:
CL
I
E
N
T
:
CA
H
O
-
0
0
2
5
0
9
9
4
SHEET TITLE:
JE
R
R
Y
N
G
O
JOB NO.
SCALE:
DATE:
DESIGNER: BS
25-0001
01/17/25
DRAFTER: AG
PR
O
P
E
R
T
C
L
A
I
M
S
A
D
J
U
S
T
E
R
10
4
8
I
R
V
I
N
E
A
V
E
N
U
E
,
S
U
I
T
E
1
0
8
7
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
0
PH
O
N
E
:
9
4
9
-
2
5
9
-
6
0
8
0
BR
Y
A
N
@
S
T
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
ST
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
12
2
2
S
O
U
T
H
L
I
N
D
A
W
A
Y
2111
M-2
MECHANICAL
FLOOR PLAN
MECHANICAL FLOOR PLAN (1/4" = 1'-0")
GE
R
A
L
D
N
O
R
M
A
N
FI
E
L
D
P
R
O
P
E
R
T
Y
C
L
A
I
M
S
S
P
E
C
I
A
L
I
S
T
NBG
#C 82777
E
SCALE: NONE
DUCT FITTING DETAIL
SCALE: NONE
DUCT HANGER DETAIL1
SCALE: NONE
TYPICAL SIDE DIFFUSER CONNECTION
SCALE: NONE
TYPICAL DIFFUSER CONNECTION
DIFFUSERS, REGISTERS, GRILLES
EXHAUST FAN SCHEDULE
2
3 4
GAS FURNACE SCHEDULE
REFRIGERANT COIL SCHEDULE
CONDENSING UNIT SCHEDULE
SHEET REFERENCE:
SHEET: OF
SHEET INFO:
REVISION DATE:
ME
R
C
U
R
Y
I
N
S
U
R
A
N
C
E
,
I
N
C
.
PR
O
J
E
C
T
:
CL
I
E
N
T
:
CA
H
O
-
0
0
2
5
0
9
9
4
SHEET TITLE:
JE
R
R
Y
N
G
O
JOB NO.
SCALE:
DATE:
DESIGNER: BS
25-0001
01/17/25
DRAFTER: AG
PR
O
P
E
R
T
C
L
A
I
M
S
A
D
J
U
S
T
E
R
10
4
8
I
R
V
I
N
E
A
V
E
N
U
E
,
S
U
I
T
E
1
0
8
7
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
0
PH
O
N
E
:
9
4
9
-
2
5
9
-
6
0
8
0
BR
Y
A
N
@
S
T
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
ST
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
12
2
2
S
O
U
T
H
L
I
N
D
A
W
A
Y
2112
M-3
SCHEDULES AND DETAILS
MECHANICAL
GE
R
A
L
D
N
O
R
M
A
N
FI
E
L
D
P
R
O
P
E
R
T
Y
C
L
A
I
M
S
S
P
E
C
I
A
L
I
S
T
NBG
#C 82777
E
“”
SHEET REFERENCE:
SHEET: OF
SHEET INFO:
REVISION DATE:
ME
R
C
U
R
Y
I
N
S
U
R
A
N
C
E
,
I
N
C
.
PR
O
J
E
C
T
:
CL
I
E
N
T
:
CA
H
O
-
0
0
2
5
0
9
9
4
SHEET TITLE:
JE
R
R
Y
N
G
O
JOB NO.
SCALE:
DATE:
DESIGNER: BS
25-0001
01/17/25
DRAFTER: AG
PR
O
P
E
R
T
C
L
A
I
M
S
A
D
J
U
S
T
E
R
10
4
8
I
R
V
I
N
E
A
V
E
N
U
E
,
S
U
I
T
E
1
0
8
7
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
0
PH
O
N
E
:
9
4
9
-
2
5
9
-
6
0
8
0
BR
Y
A
N
@
S
T
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
ST
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
12
2
2
S
O
U
T
H
L
I
N
D
A
W
A
Y
2113
M-4
SPECIFICATIONS
MECHANICAL
GE
R
A
L
D
N
O
R
M
A
N
FI
E
L
D
P
R
O
P
E
R
T
Y
C
L
A
I
M
S
S
P
E
C
I
A
L
I
S
T
NBG
#C 82777
E
PLUMBING ABBREVIATIONS PLUMBING PIPING SYMBOL LIST GENERAL NOTES DEMOLITION NOTES
SHEET REFERENCE:
SHEET: OF
SHEET INFO:
REVISION DATE:
ME
R
C
U
R
Y
I
N
S
U
R
A
N
C
E
,
I
N
C
.
PR
O
J
E
C
T
:
CL
I
E
N
T
:
CA
H
O
-
0
0
2
5
0
9
9
4
SHEET TITLE:
JE
R
R
Y
N
G
O
JOB NO.
SCALE:
DATE:
DESIGNER: BS
25-0001
01/17/25
DRAFTER: AG
PR
O
P
E
R
T
C
L
A
I
M
S
A
D
J
U
S
T
E
R
10
4
8
I
R
V
I
N
E
A
V
E
N
U
E
,
S
U
I
T
E
1
0
8
7
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
0
PH
O
N
E
:
9
4
9
-
2
5
9
-
6
0
8
0
BR
Y
A
N
@
S
T
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
ST
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
12
2
2
S
O
U
T
H
L
I
N
D
A
W
A
Y
2118
P-1
PLUMBING
NOTES AND LEGENDS
GE
R
A
L
D
N
O
R
M
A
N
FI
E
L
D
P
R
O
P
E
R
T
Y
C
L
A
I
M
S
S
P
E
C
I
A
L
I
S
T
NBG
#C 82777
E
ROOM
ROOM
ROOM
UP
ROOM
ROOM
RO
O
M
ROOM
ROOM
RO
O
M
RO
O
M
RO
O
M
ROOM
ROOM
ROOM ROOM
ROOM
ROOM
PLUMBING PLAN NOTES
GAS GENERAL NOTES
SHEET REFERENCE:
SHEET: OF
SHEET INFO:
REVISION DATE:
ME
R
C
U
R
Y
I
N
S
U
R
A
N
C
E
,
I
N
C
.
PR
O
J
E
C
T
:
CL
I
E
N
T
:
CA
H
O
-
0
0
2
5
0
9
9
4
SHEET TITLE:
JE
R
R
Y
N
G
O
JOB NO.
SCALE:
DATE:
DESIGNER: BS
25-0001
01/17/25
DRAFTER: AG
PR
O
P
E
R
T
C
L
A
I
M
S
A
D
J
U
S
T
E
R
10
4
8
I
R
V
I
N
E
A
V
E
N
U
E
,
S
U
I
T
E
1
0
8
7
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
0
PH
O
N
E
:
9
4
9
-
2
5
9
-
6
0
8
0
BR
Y
A
N
@
S
T
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
ST
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
12
2
2
S
O
U
T
H
L
I
N
D
A
W
A
Y
2119
P-2
PLUMBING
FLOOR PLAN
PLUMBING FLOOR PLAN (1/4" = 1'-0")
GE
R
A
L
D
N
O
R
M
A
N
FI
E
L
D
P
R
O
P
E
R
T
Y
C
L
A
I
M
S
S
P
E
C
I
A
L
I
S
T
NBG
#C 82777
E
PLUMBING FIXTURE SCHEDULE
GAS FIRED HOT WATER HEATER SCHEDULE
PIPE INSULATION SCHEDULE
3 SCALE: NONE
FINISHED FLOOR CLEANOUT
4 SCALE: NONE
FINISHED ROOM WALL CLEANOUT
6 SCALE: NONE
PIPE SUPPORT DETAIL
2 SCALE: NONE
FIRE RATED WALL PIPE PENETRATION DETAIL
x
x
x
1 SCALE: NONE
PIPE PENETRATION DETAIL NON-RATED WALL
5 SCALE: NONE
HOT WATER HEATER CONNECTION DETAIL
PIPING AND FITTINGS SCHEDULE
SHEET REFERENCE:
SHEET: OF
SHEET INFO:
REVISION DATE:
ME
R
C
U
R
Y
I
N
S
U
R
A
N
C
E
,
I
N
C
.
PR
O
J
E
C
T
:
CL
I
E
N
T
:
CA
H
O
-
0
0
2
5
0
9
9
4
SHEET TITLE:
JE
R
R
Y
N
G
O
JOB NO.
SCALE:
DATE:
DESIGNER: BS
25-0001
01/17/25
DRAFTER: AG
PR
O
P
E
R
T
C
L
A
I
M
S
A
D
J
U
S
T
E
R
10
4
8
I
R
V
I
N
E
A
V
E
N
U
E
,
S
U
I
T
E
1
0
8
7
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
0
PH
O
N
E
:
9
4
9
-
2
5
9
-
6
0
8
0
BR
Y
A
N
@
S
T
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
ST
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
12
2
2
S
O
U
T
H
L
I
N
D
A
W
A
Y
2120
P-3
SCHEDULES AND DETAILS
PLUMBING
GE
R
A
L
D
N
O
R
M
A
N
FI
E
L
D
P
R
O
P
E
R
T
Y
C
L
A
I
M
S
S
P
E
C
I
A
L
I
S
T
NBG
#C 82777
E
PLUMBING SPECIFICATIONS
SHEET REFERENCE:
SHEET: OF
SHEET INFO:
REVISION DATE:
ME
R
C
U
R
Y
I
N
S
U
R
A
N
C
E
,
I
N
C
.
PR
O
J
E
C
T
:
CL
I
E
N
T
:
CA
H
O
-
0
0
2
5
0
9
9
4
SHEET TITLE:
JE
R
R
Y
N
G
O
JOB NO.
SCALE:
DATE:
DESIGNER: BS
25-0001
01/17/25
DRAFTER: AG
PR
O
P
E
R
T
C
L
A
I
M
S
A
D
J
U
S
T
E
R
10
4
8
I
R
V
I
N
E
A
V
E
N
U
E
,
S
U
I
T
E
1
0
8
7
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
0
PH
O
N
E
:
9
4
9
-
2
5
9
-
6
0
8
0
BR
Y
A
N
@
S
T
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
ST
R
E
G
E
S
T
R
U
C
T
U
R
A
L
.
C
O
M
12
2
2
S
O
U
T
H
L
I
N
D
A
W
A
Y
2121
P-4
SPECIFICATIONS
PLUMBING
GE
R
A
L
D
N
O
R
M
A
N
FI
E
L
D
P
R
O
P
E
R
T
Y
C
L
A
I
M
S
S
P
E
C
I
A
L
I
S
T
NBG
#C 82777
E
STRUCTURAL CALCULATIONS
FOR
CAHO-00250994
1222 SOUTH LINDA WAY
SANTA ANA, CA 92704
1ST SUBMITTAL CALCULATONS
1048 IRVINE AVENUE, SUITE 1087
NEWPORT BEACH, CA 92660
(949)259-6080
WWW.STREGESTRUCTURAL.COM
2222222222222222
NBG
#C 82777
E
TABLE OF CONTENTS:
ITEM PAGE #
BASIS OF DESIGN 1
LOADING 1
WIND DESIGN PARAMETERS 2
SEISMIC DESIGN PARAMETERS 3-4
WIND PRESSURE (C&C) ROOF 5
WIND PRESSURE (C&C) WALLS 6
SEISMIC DESIGN FORCE 7
NEW JOIST DESIGN 8-9
LATERAL DESIGN & FOUNDATION DESIGN STATEMENT 10
1
BOD:
2022 CBC
LOADING:
DEAD LOAD:
ROOF:
TILE = 3 PSF
WATERPROOFING = 1.5 PSF
SHT'G. = 3 PSF
FRAMING = 3 PSF
INT. FINISH = 2.5 PSF
INSULATION = 1.5
MISC. = 0.5 PSF
TOTAL = 15 PSF
EXT. WALL:
STUCCO = 9 PSF
SHT'G. = 2.5 PSF
STUDS = 3 PSF
INT. FINISH = 2.5 PSF
MISC. = 1 PSF
TOTAL = 18 PSF
INT. WALL:
FINISH = 2(2.5) = 5 PSF
FRAMING = 3 PSF
MISC. = 1 PSF
TOTAL = 9 PSF
ROOF LIVE LOADING = 20 PSF
SNOW LOADING = N/A
ICE LOADING = N/A
RAIN LOADING = N/A
WIND & SEISMIC LOADING = SEE ATTACHED
ASCE Hazards Report
Address:
1222 S Linda Way
Santa Ana, California
92704
Standard:ASCE/SEI 7-16 Latitude:33.732034
Risk Category:II Longitude:-117.892757
Soil Class:D - Default (see
Section 11.4.3)
Elevation:64.01837546394228 ft
(NAVD 88)
Wind
Results:
Wind Speed 95 Vmph
10-year MRI 66 Vmph
25-year MRI 72 Vmph
50-year MRI 76 Vmph
100-year MRI 81 Vmph
Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2
Date Accessed: Wed Jan 15 2025
Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear
interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds
correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability =
0.00143, MRI = 700 years).
Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2.
Page 1 of 3https://ascehazardtool.org/Wed Jan 15 2025
2
SS : 1.297
S1 : 0.463
F a : 1.2
F v : N/A
SMS : 1.556
SM1 : N/A
SDS : 1.037
SD1 : N/A
T L : 8
PGA : 0.552
PGA M : 0.662
F PGA : 1.2
Ie : 1
C v : 1.359
Seismic
Site Soil Class:
Results:
Data Accessed:
Date Source:
D - Default (see Section 11.4.3)
USGS Seismic Design Maps
Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8.
Wed Jan 15 2025
Page 2 of 3https://ascehazardtool.org/Wed Jan 15 2025
3
The ASCE Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any
kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or
has been extrapolated from maps incorporated in the ASCE standard. While ASCE has made every effort to use data obtained from reliable
sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or
quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation,
relationship, or sponsorship of such third-party content by or from ASCE.
ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent
professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such
professionals in interpreting and applying the contents of this Tool or the ASCE standard.
In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors,
employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential
damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by
law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data
provided by the ASCE Hazard Tool.
Page 3 of 3https://ascehazardtool.org/Wed Jan 15 2025
4
WIND PRESSURE CALCULATION (COMPONENTS & CLADDING)
V=95 MPH
Elev.=577 ft
Kzt=1
Kd=0.85
Ke=0.979
qz = 0.00256(Kz)(Kzt)(Kd)(Ke)(V2)= 19.2324591 Kz (PSF)
Kz (EXP. C) qz (PSF)
0-15'0.85 16.34759027
20'0.9 17.30921323
25'0.94 18.07851159
30'0.98 18.84780996
40'1.04 20.00175751
50'1.09 20.96338046
60'1.13 21.73267883
Lrafter = 8.5 ft
Spacing =2 ft
Atrib. =17.000 ft2
Amin. = 24.083 ft2 A=L(L/3)
Aeff. =24.083 ft2
GCp:
ZONE 1 ZONE 2 ZONE 2n&2r ZONE 2e ZONE 3e ZONE 3r
0.35 0.35 0.35 0.35 0.35 0.35
-1.85 -2.5 -2.5 -1.85 -2.5 -2.95
GCpi:
0.18 -0.18
Zone 1: 2.03 [(GCp)-(GCpi)]Worst Case
Zone 2: 2.68 [(GCp)-(GCpi)]Worst Case
Zone 2n/2r: 2.68 [(GCp)-(GCpi)]Worst Case
Zone 2e: 2.03 [(GCp)-(GCpi)]Worst Case
Zone 3e: 2.68 [(GCp)-(GCpi)]Worst Case
Zone 3r: 3.13 [(GCp)-(GCpi)]Worst Case
p=qh[(GCp)-(GCpi)](PSF)
p ULT. (PSF)p ASD (PSF)p ULT. (PSF)p ASD (PSF)p ULT. (PSF)p ASD (PSF)p ULT. (PSF)p ASD (PSF)p ULT. (PSF)p ASD (PSF)p ULT. (PSF)p ASD (PSF)
0-15'33.19 19.91 43.81 26.29 43.81 26.29 33.19 19.91 43.81 26.29 51.17 30.70
20'35.14 21.08 46.39 27.83 46.39 27.83 35.14 21.08 46.39 27.83 54.18 32.51
25'36.70 22.02 48.45 29.07 48.45 29.07 36.70 22.02 48.45 29.07 56.59 33.95
30'38.26 22.96 50.51 30.31 50.51 30.31 38.26 22.96 50.51 30.31 58.99 35.40
40'40.60 24.36 53.60 32.16 53.60 32.16 40.60 24.36 53.60 32.16 62.61 37.56
50'42.56 25.53 56.18 33.71 56.18 33.71 42.56 25.53 56.18 33.71 65.62 39.37
60'44.12 26.47 58.24 34.95 58.24 34.95 44.12 26.47 58.24 34.95 68.02 40.81
Zone 3rZone 1 Zone 2 Zone 2n/2r Zone 2e Zone 3e
5
WIND PRESSURE CALCULATION (COMPONENTS & CLADDING)
V=95 MPH
Elev.=577 ft
Kzt=1
Kd=0.85
Ke=0.979
qz = 0.00256(Kz)(Kzt)(Kd)(Ke)(V2)= 19.2324591 Kz (PSF)
Kz (EXP. C) qz (PSF)
0-15'0.85 16.3475903
20'0.9 17.3092132
25'0.94 18.0785116
30'0.98 18.84781
40'1.04 20.0017575
50'1.09 20.9633805
60'1.13 21.7326788
Lstud = 8 ft
Spacing =1.333 ft
Atrib. =10.664 ft2
Amin. = 21.333 ft2 A=L(L/3)
Aeff. =21.333 ft2
GCp:
ZONE 4 ZONE 5
0.95 0.95
-1.05 -1.3
GCpi:
0.18 -0.18
Zone 4: 1.23 [(GCp)-(GCpi)]Worst Case
Zone 5: 1.48 [(GCp)-(GCpi)]Worst Case
p=qh[(GCp)-(GCpi)](PSF)
p ULT. (PSF)p ASD (PSF)p ULT. (PSF)p ASD (PSF)
0-15'20.11 12.06 24.19 14.52
20'21.29 12.77 25.62 15.37
25'22.24 13.34 26.76 16.05
30'23.18 13.91 27.89 16.74
40'24.60 14.76 29.60 17.76
50'25.78 15.47 31.03 18.62
60'26.73 16.04 32.16 19.30
ZONE 4 ZONE 5
6
SEISMIC DESIGN
SDS 1.037 SDC D
S1 0.463
Fv 1.85
SD1 0.571033 SDC D
Ie 1
R 2
hn 11.5 FT
Ct 0.02
x 0.75
Ta 0.124897 SEC Ta = Cthn
x
TL 8 SEC
Cs 0.519 Cs = SDS/(R/Ie)
Cs max.2.286 Cs = SD1/(T)(R/Ie)
Cs min.0.046 Cs = 0.044SDSIe ≥ 0.01
C s DESIGN 0.519 ULT
C s DESIGN 0.36295 ASD
W
Roof DL 25 PSF
Partition 10 PSF
Roof W 35 PSF
Floor DL 25 PSF
Partition 20 PSF
Floor W 45 PSF
Total W 80 PSF
V 41.480 PSF (ULT)V = CsW
V 29.036 PSF (ASD)
7
8
NEW JOIST DESIGN:
D = 15 PSF
Lr = 20 PSF
W = 16 PSF DOWN / 26 PSF UP
D + Lr = 35 PSF
D + 0.75Lr + 0.75(0.6W) = 42 PSF -- GOV DOWN
0.6D - 0.6W = -17 PSF -- UP
DOWN:
w = 2'(42 PSF) = 84 PLF
L = SAY 14'
M = WL^2/8 = 2058 FT-LBS = 24696 IN-LBS
V = WL/2 = 588 LBS
CHOOSE (2)2X6 -- S = 2(7.56 IN3) = 15.12 IN3, A = (2)(8.25 IN2) = 16.5 IN2
fb req = M/S = 1633.3 PSI
fv req = 3V/2A = 53.5 PSI
CHOOSE DF-L GR. #2
Fb = 900 PSI
Fv = 180 PSI
Fb' = (900 PSI)(1.6)(1.3)(1.15) = 2152.8 PSI > 1633.3 PSI -- OK
Fv' = (180 PSI)(1.6) = 288 PSI > 53.5 PSI -- OK
UP:
M = 9996 IN-LBS
V = 238 LBS
fb req = 661.1 PSI
fv req = 21.6 PSI
lu = 168"
le = 1.68(168")+3(5.5") = 298.74"
d = 5.5"
b = 2(1.5") = 3"
Rb = 13.5
Fbe = 3818.9 PSI
Fb* = (900 PSI)(1.6)(1.3)(1.15) = 2152.8 PSI
Fbe/Fb* = 1.774
CL = 1.459 - 0.514 = 0.945
Fb' = 2034.3 PSI > 661.1 PSI -- OK
Fv' = 288 PSI > 21.6 PSI -- OK
9
DEFLECTION CHECK:
I = 2(20.80 IN4) = 41.6 IN4
E = 1,600,000 PSI
L = 13.5' = 162" ACTUAL
w = 15 PSF(2') = 30 PLF = 2.5 PLI (DEAD ONLY)
w = 20 PSF(2') = 40 PLF = 3.3 PLI (Lr ONLY)
Lr DEF = (5wl^4)/(384EI) = 0.4"
D DEF = 0.3"
DELTA T = 1.5(0.3")+0.4" = 0.85"
ALLOW:
L/240 = 0.68"
L/180 = 0.9"
Lr -- OK
D+Lr -- OK
CHOOSE (2)2X6 DF-L #2 GR.
10
LATERAL SYSTEM:
ROOF DIAPHRAGM = PATCHING ANY HOLES W/ SIMILAR MATERIALS (NO SIGNIFICANT
STRUCTURAL DAMAGE PRESENT). CAPACITY TO REMAIN CONSISTENT WITH DESIGN AT
TIME OF CONSTRUCTION.
FLOOR DIAPHRAGM = NO DAMAGE. NO CHANGE.
WALLS = NO CHARRING OBSERVED IN STRUCTURAL WALLS. EXISTING LATERAL FORCE
RESISTING SYSTEM TO REAMIN. (NO SIGNIFICANT STRUCTURAL DAMAGE PRESENT.)
FOUNDATION SYSTEM:
DO DAMAGE OBSERVED TO FOUNDATION ELEMENTS. ALL ELEMENTS TO REMAIN.
_______________________
Page 1 of 1
EXISTING ONE & TWO FAMILY DWELLINGS
ELECTRICAL SERVICES UNDERGROUND
EXCEPTION
CEC 2022 ELC-04
All new utility connections are required to be installed below grade by Santa Ana Municipal Code 41-
626(b). There is a standing exception for one and two family dwellings. This exception
applies only when the new electrical service is designed to be fed from below grade as well as
overhead.
This diagram is a typical unit. The utility is able to feed this cabinet from the top or the bottom without
interfering with the distribution wiring. All the circuit breakers and branch circuits are contained in the
circuit breaker side of this cabinet.
Only listed combination overhead and underground feed service boxes may be used to connect to
an overhead utility drop. This exception to an underground fed service applies only to existing single
family and two family residences.
Planning & Building Agency
Permits & Plan Check Section
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
Rigid
Conduit
Service
Entrance
Conductor
Riser
Underground
Service
Lateral
METER
Rev. 1/21/2020