Loading...
HomeMy WebLinkAbout414 E Pine Unit B - PlanBldg# 101124973 Elec# 20186850 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. nc INDEX MSP (E)100A Main Service Panel AC............ (N) 30A AC Disconnect JB.......................(N) Junction Box 17 ........................ (N) Microinverter ................... Solar Module ............• EMT type Conduit — ............. Fire Setback Line Total Roof Area: 779 Total Module Area: 100 12.83% of Coverage " Roof access is not located in areas that require placement of ground ladders over exterior wall openings CRC R331.4.1. NOTE:A 36-inchwide pathway shall be provided to the emergency escape and rescue opening. All electrical work shall be designed per 2023 Los Angeles City Electrical Code, 2022 California Electrical Code, and 2020 National Electrical Code and 2022 Building Energy Efficiency Standards. 110.2 Approval: All electrical equipment shall be labeled, listed, or certified by a Nationally Recognized Testing Laboratory accredited by the United States Occupational Safety Health Administration. EQUIPMENT ELEVATION A SERVICE POINT & E Pine St W 270 N 0° S 180 SCALE: 3/32" = 1'-0" E go, CONTRACTOR FOR PERMI ISSUA Maste Date: ►%A/C AWS Electrical & Solar Inc. Address: 11750 Roscoe Blvd Los Angeles, CA 91352 Phone number: 1-818-484-3264 License: C-10 #901196 Florin Muntean SITE MAP & PV LAYOUT SOLAR MODULES 5 REC Solar 400 Watt Model # REC400AA Pure INVERTER INVERTER TYPE: Micro: 5 Enphase IQ7A Model # IQ7A-72-2-US(240V) DATE- 07124W q� EN , Project Na rCa No.74200 Jeremy L®vine ik Property Adre54*1 414 E Pine0Santa Ana Project Scale: PV SYSTEM AS INDICATED F_PV 1.0 —11 E STRUCTURAL REVIEW ONLY MODULES ON ROOF Solar Modul Blockin Attachment Rafter: 2 x 6 @ 24" O.C. DF#2 If Plywood & Building Felt 2 x 8 1 Layer of Comp Shinqle IRONRIDGE ATTACHMENT AND RACKING DETAILS 3. 6 1.02 1 .0 7 3. d �0 IRONRIDGE STOPPER SLEEVE .5 IRONRIDGE UNIVERSAL PV MODULE FASTENING OBJECT IRONRIDGE UNIVERSAL C IRONRIDGE RAIL D FASTENING OBJECT (E) RAFTERS IRONRIDGE FLASHFOOT2 SIDE VIEW IRONRIDGE RAIL IRONRIDGE FLASHFOOT2 A PV MODULE, BY OTHERS PV MODULE, BY OTHERS IRONRIDGE IRONRIDGE - RAIL RAIL FRONT VIEW ME) ROOF ) ROOF EMBRANE MEMBRANE IRONRIDGEIRONRIDGE IRONRIDGE FLASHFOOT2 FLASHFOOT2 5/16" STAINLESS STEEL LAG SCREW MIN. 2.5' EMBED INTO FRAMING MEMBER (E) BUILDING (E) BUILDING STRUCTURE STRUCTURE A DETAIL FLASHF00T2 SIDE D DETAIL FL4SHFOOT2 FRONT IRONRIDGE UNIVERSAL IRONRIDGE RAIL IRONRIDGE STOPPER SLEEVE PV MODULE FRAME FASTENING OBJECT IRONRIDGE UNIVERSAL IRONRIDGE UNIVERSAL rFA MODULE FRAME FASTENING OBJECT FASTENING OBJECT PV MODULE FRAMEONRIDGE UNIVERSAL PV MODULE FRAME IRONRIDGE RAILSTENING OBJECT IRONRIDGE STOPPE IRONRIDGE RAIL SLEEVE �\ DETAIL, MID CLAMP PLAN C DETAIL MID CLAMP FRONT B DETAIL. END CLAMP PLAN B DETAIL END CLAMP FRONT ATTACHMENT RAIL — — — — — — — — — — — — Rafter: 2 x 6 @ 24" O.C. POINT LOAD CALCULATION PER ARRAY Module Weight (Ibs) 45 # Of Modules 5 Total Module Weight (Ibs) 225 Rack Weight (Ibs) 45 Microinverters Weight (Ibs) 11.9 Total System Weight (Ibs) 281.9 # Of Standoffs 9 Max Span Between Standoffs (in) 72 Loading Per Standoff (Ibs) 31.32 Total Area (sq.ft.) 100 Loading (PSF) 2.81 DESIGN CRITERIA Modules: 5 Max Distributed Load: 3 PSF CONTRACTOR Approved FOR PERM T ISSUAN Master f® Date: AWS Electrical & Solar Inc. Address: 11750 Roscoe Blvd Los Angeles, CA 91352 Phone number: 1-818-484-3264 License: C-10 #901196 Florin Muntean ATTACHMENT LAYOUT SOLAR MODULES 5 REC Solar 400 Watt Model # REC400AA Pure INVERTER INVERTER TYPE: Micro: 5 EnphaselQ7A Model # IQ7A-72-2-US(240V) DATE.- 07/ R91014 Project JererrLevin �J0.74200ME Pro a dr s # 414 E ' , n Santa An � Project: Scale: PV SYSTEM AS INDICATED F_PV 5.0 //� IRON RIDGE The Strongest Attachiiient in Solar Iron Ridge FlashFoot2 raises the bar in solar roof protection. The unique water seal design is both elevated and encapsulated, delivering redundant layers of protection against water intrusion. In addition, the twist -on Cap perfectly aligns the rail attachment with the lag bolt to maximize mechanical strength. Twist -On Cap FlashFoot2's unique Cap design encaps the lag bolt and locks into place with a si twist. The Cap helps FlashFoot2 deliver superior structural strength, by aligning the rail and lag bolt in a concentric load path. Single Socket Size A custom -design lag bolt allows you to install FlashFoot2 with the same 7/16" socket size used on other Flush Mount System components. FlashFoot2 Three -Tier Water Seal FlashFoot2's seal architecture utilizes three layers of protection. An elevated platform diverts water away, while a stack of rugged components raises the seal an entire inch. The seal is then fully-encapuslated by the Cap. FlashFoot2 is the first solar attachment to pass the TAS-100 Wind -Driven Rain Test. Water -Shedding Design An elevated platform diverts water away from the water seal. Installation Features e A Alignment Markers Quickly align the flashing with chalk lines to find pilot holes. C B Rounded Corners Makes it easier to handle and insert under the roof shingles. c Reinforcement Ribs A Help to stiffen the flashing and prevent any bending or crinkling during installation. Benefits of Concentric Loading 1200 FlashFoot2 loon Traditional solar attachments have a horizontal offset between the rail and lag 800 a FleahFoot sLeaCing Competitor bolt, which introduces leverage on the lag Q 600 bolt and decreases uplift capacity. aoo • Low -Cost Competitor FlashFoot2 is the only product to align the zoo rail and lag bolt. This concentric loading design results in a stronger attachment for o 1 the system. Rail -to -Lag Offset (in) Testing & Certification Structural Certification Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7. Water Seal Ratings Water Sealing Tested to UL 441 Section 27 "Rain Test" and TAS 100-95 "Wind Driven Rain Test' by Intertek. Ratings applicable for composition shingle roofs having slopes between 2:12 and 12:12. U L 2703 Conforms to UL 2703 Mechanical and Bonding Requirements. See Flush Mount Install Manual for full ratings. 0 2016Ironfiidge, Inc. At rights reserved. Ysft www.irgvldge.com or call 1.9tf0-227-9=for more i lomratiom Version to CONTRACTOR Approved FOR PERM T ISSUAN r Master Date: AWS AWS Electrical & Solar Inc. Address: 11750 Roscoe Blvd Los Angeles, CA 91352 Phone number: 1-818-484-3264 License: C-10 #901196 Florin Muntean ATTACHMENT DATA SHEET SOLAR MODULES 5 REC Solar 400 Watt Model # REC400AA Pure INVERTER INVERTER TYPE: Micro: _�L EnphaselQ7A Model # IQ7A-72-2-US(240V) DATE.- 07/ N9( Pro ect N e: No. 74200 `P Jeremytbvine Property Ad re 414 E Pin iv Santa Ana, A 7 Project: Scale. PV SYSTEM AS INDICATED D 10.0 Data Sheet Enphase Microinverters Region AMERICAS Enphase IQ 7A Microinverter 0 To learn more about Enphase offerings, visit enphase.com The high-powered smart grid -ready Enphase IQ 7A Micro- dramatically simplifies the installation process while achieving the highest system efficiency for systems with 60-cel I and 72-cell modules. Part of the Enphase IQ System, the IQ 7A Micro integrates with the Enphase IQ Envoy', Enphase IQ Battery', and the Enphase Enlighten- monitoring and analysis software. The IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. High Power • Peak output power 366 VA @ 240 VAC and 295 VA @ 208 VAC Easy to Install Lightweight and simple Faster installation with improved, lighter two -wire cabling Built-in rapid shutdown compliant (NEC 2014, 2017 & 2020) Efficient and Reliable Optimized for high powered 60-cell and 72-cell modules Highest CEC efficiency of 97 i More than a million hours of testing Class II double -insulated enclosure UL listed Smart Grid Ready Complies with advanced grid support, voltage and frequency ride - through requirements Envoy and Internet connection required Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) ':I ENPHASE Enphase IQ 7A Microinverter INPUT (DC) IQ7A-72-2-US Commonly used module pairings' 295 W-460 W + Module compatibility 60-cell, 66-cell and 72-cell PV modules Maximum input DC voltage 58 V Power point tracking voltage range2 18 V-58 V Min/Max start voltage 33 V / 58 V Max DC short circuit current (module Isc)' 15 A Overvoltage class DC port II DC port backfeed current 0 A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required, AC side protection requires max 20A per branch circuit OUTPUT (AC) @ 240 VAC @ 208 VAC Peak output power 366 VA 295 VA Maximum continuous output power 349 VA 290 VA Nominal (L-L) voltage/range4 240 V / 211-264 V 208 V / 183-229 V Maximum continuous output current 1,45 A (240 VAC) 1,39 A (208 VAC) Nominal frequency 60 Hz Extended frequency range 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms Maximum units per 20 A (L-L) branch circuit' 11 (240 VAC) 11 (208 VAC) Overvoltage class AC port III AC port backfeed current 18 mA Power factor setting 1.0 Power factor (adjustable) 0.85leading... 0.85lagging EFFICIENCY @240 VAC @208 VAC GEC weighted efficiency 97.0 % 96.5% MECHANICAL Ambient temperature range -40°C to +60°C Relative humidity range 4%to 100`Y (condensing) Connector type: DC(IQ7A-72-2-US) MC4 Dimensions (HxWxD) 212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 Ibs) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double -insulated, corrosion resistant polymeric enclosure Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load -break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1. UL1741/IEEE1547. FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017 and NEC 2020, section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 1. No enforced DC/AC ratio. See the compatibility calculator at h1UajLeaittasecom/emus/suotwrt/module-com4iLbjhty. 2. CEC peak power tracking voltage range is 38 V to 43 V 3. Maximum continuous input DC current is 10.2A 4. Voltage range can be extended beyond nominal if required by the utility 5 Limas may vary Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com Z 2021 Enphase Energy All rights reserved. Enphase, the Enphase logo. Enphase 10 7A, Enphase IQ Battery, Enphase Enlighten, Enphase IQ E N P H A S E Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc Data subject to changey 11-04-2021 CONTRACTOR Approved FOR PERMIT ISSUAN r A Master I'� Date: AIA/C i'+'1i r AWS Electrical & Solar Inc. Address: 11750 Roscoe Blvd Los Angeles, CA 91352 Phone number: 1-818-484-3264 License: C-10 #901196 Florin Muntean INVERTER DATA SHEET SOLAR MODULES 5 REC Solar 400 Watt Model # REC400AA Pure INVERTER INVERTER TYPE: Micro: _�L EnphaselQ7A Model # IQ7A-72-2-US(240V) DATE.- 0712612025 Project Name: Jeremy Levine Property Adress: 414 E Pine St, Unit B, Santa Ana, CA 92701 Project: Scale: PV SYSTEM AS INDICATED 7DF 6.0 Enphase, Energy// Rapid Shutdown Rapid shutdown is built-in The 2014 and 2017 editions of the National Electrical Code (NEC 2014/NEC What's new In Section 690.12? 2017) added new rapid shutdown requirements for PV systems installed on NEC 2014/2017, Section 690.12 applies buildings. Enphase Microinverters fully meet rapid shutdown requirements 111 to PV conductors over 10 feet from the new code without the need to install any additional electrical equipment. the PV array and requires that the conductors power down to 30 volts and 240 volt-amperes within 10 seconds of rapid shutdown initiation. String inverters require work arounds for rapid shutdown Work around. Specialized Rapid Shutdov, electrical box installed on tt roof within 10 feet of array. Work around. Shutoff switch that is easily accessible to first responders on the ground. Work around. Extra conduit in installation. Residential String Inverter Work around. String inverter installed on roof, a hostile environment that string Inverters are not built to live in. Commercial String Inverter Enphase comes standard with rapid shutdown capability All Enphase microin- verters, even those that were previously installed, inherently meet rapid shutdown requirements, no additional equipment or workarounds needed Residential Microinverter Enphase microinverters can safely shut down automatically, leaving only low -voltage DC electricity isolated to the PV module Commercial Microinverter To learn more, visit enphase.com v E N P H A S E QUICK INSTALL GUIDE ENPHASE Install the Enphase IQ7, IQ7+, IQ7A, and IQ7X Microinverter To install Enphase IQ Series Microinverters, read and follow all warnings and instructions in this guide and the Enphase IQ7, I07+, and IQ7X Microinverter installation and Operation Manual at enohase.com/support- Safety warnings are listed at the end of this guide. The Enphase microinverter models listed in this guide do not require grounding electrode conductors (GEC), equipment grounding conductors (EGC), or grounded conductors (neutral). The microinverter has a Class II double -insulated rating, which includes ground fault protection (GFP). To support GFP use only PV modules equipped with DC cables labeled 'PV Wire or'PV Cable". IMPORTANT: The Enphase IQ Series Microinverters include AC and DC connectors integrated into the bulkhead. The AC port connects to an IQ Cable or IQ Field Wlreable Connector. IQ7 Microinverter Seres has IQ DC bulkhead for DC connection and Q-DCC-2 bulkhead adapter cable for MC4 connection. UL has evaluated the MC4 connector for intermatability with Staubli MC4 connectors, whose cable coupler models are'PV-KST4/...-UR, PV-KBT4/..: UR PV-KBT4- EV02/.. -UR, and PV-KST4-EV02/.. -UR . NOTE The installer must check the manufacturing date of the products to ensure that the installation date is within one year of the manufactured date of the products. Contact your local distributor to validate the date code. PREPARATION D) Ensure that you have the following items A) Install the Enphase Installer App and open it to login to your Enphase account. With this app, you can scan a microinverter serial numbers and connect to the IQ Gate ' way to track system installation progress. To download, - go to enphase cnm/installea= or scan the QR code. B) Refer to the following table and check PV module electrical compatibility at enohase.com/errus/support/module-compatibility. Modal Dc mrxrctar PV nwdub* cdl mud IQ7-6o-2-US Staubli MC4 Pair with 60�11/120-halfcell modules IQ7PIus-72-2-US Staubh MC4 Pair with 60cell/120­half-cell, 66-cell/132- half-cell. w 72cell/144-half-cell IQ7A-72-2-US Staubli MC4 Pair with 60cell/120-half-cell,66-oe11/132- halfcell, a 72-cell/144half-cell IQ7X-96-2-US Staubli MC4 Par only with 96od1 modules ' Enphase IQ Series Microinverters are compatible with bifaciaI PV modules if thetemperabre-aqusted electrical parameters (maximum power, voltage, aril current) ofthe modules, considering the front side electrical parameters (i.e., 0% back side rein), are within the allowable rr croinverter input parameters range. C) In addition to the Enphase microinverters, PV modules, and racking, you will need the following Enphase items: • IQ Gateway (model ENWQ-AM1-240) communications gateway or IQ Combiner (check ennha� m for models): Tomonnor solar production. • Tie wraps or cable clips (Q-CUP-1 00) • IQ Sealing Caps (0-SEAL-10): For any unused connectors on the IQ Cable • IQTerminator (Q-TERM-1%One required atthe end of eachAC cable segment • IQ Disconnect Tod (Q-DISC-10) 10 Cable Cable model Cornector PV module orientation Conrxsctors apadng* per box AC junction box. • Tools: Screwdrivers, wire cutter, voltmeter, torque wrench, sockets, and wrenches for mounting hardware. E) Protect your system with lightning and surge suppression devices- it is also important to have insurance that protects against lightning and electrical surges. F) Plan your AC branch circuits to meet the following limits for the maximum number of microinverters per branch when protected with a 20 A over -current protection device (OCPD). Maximum* nurrdw of IQ Mivoimersers per AC branch circuit - angle -phase 240 V IQ7 IQ7+ IQ7A IQ7X 16 13 11 12 208 V IQ7 IQ7+ IQ7A IQ7X 13 11 11 10 * Limits may vary. Refer to the local requirements to define the number of microinverters per branch in your area. G ) Size the AC wire gauge to account for voltage rise- Select the wire size based on the distance from the beginning of the IQ Cable to the breaker in the load center. Design for a voltage nse of less than 2% for these sections. Fordetails, referto the Voltage Rise-Fechnical Brief at enphasecom/support Best practice: Center -feed the branch circuit to minimize voltage rise in a fully -populated branch. III I1111111111111111111111111111111111111 I I I11 140-00196-04 CONTRACTOR Approved FOR PERMIT ISSUAN r. A Master I'� Date: AIAic 0 AWS Electrical & Solar Inc. Address: 11750 Roscoe Blvd Los Angeles, CA 91352 Phone number: 1-818-484-3264 License: C-10 #901196 Florin Muntean ENPHASE RAPID SHUTDOWN, COMPATIBILITY WITH PV SOLAR MODULES 5 REC Solar 400 Watt Model # REC400AA Pure INVERTER INVERTER TYPE: Micro: 5 Enphase IQ7A Model # IQ7A-72-2-US(240V) DATE.- 0712612025 Project Name: Jeremy Levine Property Adress: 414 E Pine St, Unit B, Santa Ana, CA 92701 Project: Scale: PV SYSTEM AS INDICATED FD7 7.0 C ZI REC ALPHOC PURE SERIES PRODUCT SPECIFICATIONS E GENERALDATA Cell type: 132 half -cut REC heterojurx tion bifacial cells with lead-free, gapless technology, 6 strings of 22 cells in series Glass: 0.13 in (32 rem) so[ arglasswithanti-reflecfive surfacetreatment In accordance with EN 12150 Backsheet Highly resistant polymer (black) Frame: Anodized aluminum (black) Junction box: 3-part.3 bypass diodes, lead-free IP68rated, inaccordance with IEC62790 Connectors: Staubli MC4PV-KBT4/KST4(4mm2) Inaccordancewith I EC 6285Z IP68onlywhen connected Cable: 12 AWG (4 mm2)PV wire, 43+ 47 in(11+1.2m) i n a cconla n ce wi th E N 50618 Dimensions: 71.7x40 x 1.2in (19.91 ft2)/ 1821 x 1016 x 30 non (1.85 m) Weight: 45lbs(2a5kg) Origin: Made in Singapore CONTRACTOR Approved -- FOR PERMIT ISSUAN Master ID:, E \\�RE C Date: ILARS MOST TRUSTED AWS' AWS Electrical & Solar Inc. ffi(1,11 9o, I35: __ 46P(16.11 . i ❑ 153.716AS) lloo y3.31 + 6.030.2 ID24f:0.011 - S o ■ "1 11302 IQ43x0Ai1 - 2o.s-.5 120014]21 - - loa0.021 1s3.716.osI r 4511.91 ]25 W91 671 .3. 26.4 SA.12 3 Measurements in rem Iron ELECTRICAL DATA PowerOutput-P,,,,(Wp) 390 Product 395 Code': RECxxxAA Pure 405 410 400 Watt Class Sorting-(W) 0/+5 0/+5 0/+5 0/+5 0/+5 Nominal PowerVoltage-V.(V) 40.6 41.0 41A 41.8 42.2 F Nominal Power Current - I_(A) 9.61 9.64 9.67 9.69 9.72 to Open C rcuitVoltage-Vat(V) 48.4 48.6 48.8 49.1 49A Short CircuitCurrent-IX(A) 10.38 10.39 10.40 10.41 10.42 PowerDensity(W/ftz 19.6 19.8 20.1 20.3 20.6 Panel Efficiency(%) 21.1 214 21.6 21.9 22.2 Power Output -P,a,x(Wp) 297 301 305 308 312 Nominal Power Voltage -V_(V) 38.3 38.6 39.0 39.4 39.8 Nominal Power Current-1 ,(A) 7.77 7.79 7.82 7.83 7.85 Z Open CircuitVoltage-V,_,(V) 45.6 45.8 46.0 46.3 46.6 Short Circuit Current -I.(A) 8.38 8.39 a40 8:41 8.42 Values at standardtestmndidore(STGairniassAM 15 Irradiance1075 W/sgft 0000 W/m3, tenperature77°F(25'C) basedonaproductimspread withatoleranceofIR V,r&I,;33%wtMn"mttdass.Noram1moMeopaahngtmperature(WOTarm AM15,lmadim e87DWM •enT,er-:,re':3Yf (2CrCj wAn<Jsr . ed 33 k,/s?1 m js) "4Mmre r. ex innc�ate=e hener�inal power cla<,s (P::..,)at STC abote MAXIMUM RATINGS WARRANTY Operational temperature:-40...+I85`1` Standard RECProTnet Maxim um sys tem voltage: 1000V lnstalledbyyanREC No Yes Yes dSolarProfessonal Maxim urn te st Ice d (fro nt): +7000Pa046lbs/ftl' stemS@e All Sy,e 425kW25-500kW Maxim um test load (rear): -4000Pa(83.5lbs/ftj' Product Warranty (yrs) 20 25 25 Max series fuse rating: 25A Power Warranty (yrs) 25 25 25 Max reverse current: 25A Labor Warranty (yrs) 0 25 10 " See lnstallationrnmual for mountl Instrudlons Design load Power in Yearn 98% 98% 99% -Test load/15 safetyWor) AnnualDegradatlon 025% 0.25% 0.25% PowerinYear25 92% 92% 92% TheREC ProTmstWananty Isonlyyavallahle on Panels purchased throughanREC Certified5Wa Professional installer. Waranty cDndnl.apply. Smwww.mrgmup.com for more details. Available from: Foundedin 1996,REC Group isan international pioneeringsolarenergy company dedic atedto empowering consumers with clean, affordable solar power. As Solar's Most Trusted, REC is committed to high quality, innovation, and a low ERFORMANEF carbon footprint inthesoiarmaterials and solar panels it manufactures. Headquarteredin Norway with operational headquarters in Singapore. REC also has regional hubs in N orth America, Europe, and Asia-Pacifi c CERTIFICATIONS IEC 61215 2016. IEC 617302016, U L 61730 17 21 IEC 62804 PID IEC61701 Salt Mist IEC62716 Ammonia Resistance UL61730 FireTypeClass2 IEC 62782 Dynamic Mechanical Load IEC61215-22016 Hail5tone(35mm) IEC62321 Lead-freeacetoRoHSEUS63/2015 15014001.150 9001. IEC45001, IEC 62941 TEMPERATURE RATINGS' Nominal ModuleOperatingTemperature. 44'C(a2'C) Temperature coefficient ofP,,,x:-0.24%/'K Temperature coefficient ofVo,:-0.24%/'K Temperature coefficient of Ix: 0.04 %/' K The!empe,awre coeffidi rrss tared are linear val ues DELIVERY INFORMATION Panels per pallet: 33 Panels per 40ft GP/high cube container. 792 (24 pallets) Panels per53 fttruck: 891(27 pallets) LOW LIGHTBEHAVIOUR Typical low irradiance performance of module atSTC: .............................e Inadarxe (W/m') 20TuasSouth LTO. REC 20TuasSouthAvel4 k� Singapore 637312 post@recgroup.com www.recgroup.com Address: 11750 Roscoe Blvd Los Angeles, CA 91352 Phone number: 1-818-484-3264 License: C-10 #901196 Florin Muntean MODULE DATA SHEET SOLAR MODULES 5 REC Solar 400 Watt Model # REC400AA Pure ry 0 INVERTER 8 INVERTER TYPE: Micro: IV 5 EnphaselQ7A Model # IQ7A-72-2-LIS(240V) z DA TE.- 0 �O*4� Pro'ect ~me S 2 - No.74200 JererrWLevine e Pro Ad 414 E ,t,_ Santa An , 0 Project. Scale: PV SYSTEM LAS INDICATED 7DF 8.0 CONTRACTOR CV IRONRIDGE IN tasheet Roof Mount System Built for solar's toughest roofs. Iron Ridge builds the strongest roof mounting system in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings. and is also why our products are fully certified. code compliant and backed by a 20-year warranty. Strength Tested 0% All components evaluated for superior structural performance. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. ® Integrated Grounding UL 2703 system eliminates separate module grounding components. ® PE Certified Pre -stamped engineering letters available in most states. bEEEES Design Software Online tool generates a complete bill of materials in minutes. 20 Year Warranty ' Twice the protection offered by competitors. - XR Rails XR10 Rail �i A low -profile mounting rail for regions with light snow. 6'spanning capability Moderate load capability Clear & black anod. finish Attachments FlashFoot Anchor, flash, and mount with all -in -one attachments. • Ships with all hardware IBC & IRC compliant Certified with XR Rails — Clamps & Groundinp End Clamps Slide in clamps and secure modules at ends of rails. Mill finish & black anod. Sizes from 1.22" to 2.3" Optional Under Clamps Free Resources XR100 Rail The ultimate residential solar mounting rail. 8' spanning capability Heavy load capability Clear & black anod. finish Slotted L-Feet Drop -in design for rapid rail attachment. • High -friction serrated face Heavy-duty profile shape Clear & black anod. finish Grounding Mid Clamps r Attach and ground modules in the middle of the rail. Parallel bonding T-bolt Reusable up to 10 times Mill & black stainless XR1000 Rail A heavyweight mounting rail for commercial projects 12' spanning capability Extreme load capability Clear anodized finish Standoffs Raise flush or tilted systems to various heights • Works with vent flashing Ships pre -assembled 4" and 7" Lengths T-Bolt Grounding Lugs r Ground system using the rail's top slot. Easy top -slot mounting Eliminates pre -drilling Swivels in any direction Datasheet Internal Splices All rails use internal splices for seamless connections. Self -tapping screws Varying versions for rails Grounding Straps offered Tilt Legs Tilt assembly to desired angle, up to 45 degrees. • Attaches directly to rail Ships with all hardware Fixed and adjustable Accessories Provide a finished and organized look for rails. Snap -in Wire Clips Perfected End Caps UV -protected polymer Design Assistant NABCEP Certified Training Go from rough layout to fully 1 Earn free continuing education credits, engineered system. For free. �•► while learning more about our systems. V Go to Irur 2M4 konRidge, Inc. All rights reserved. Via# www.irenridge.com or oaN 1-8DO-227-9101 for mom iMarmstion. Version 1.42 Approved -- FOR PERMIT ISSUAN Master ID:, E Date: A XAIC 1C AWS Electrical & Solar Inc. Address: 11750 Roscoe Blvd Los Angeles, CA 91352 Phone number: 1-818-484-3264 License: C-10 #901196 Florin Muntean RACKING DATA SHEET SOLAR MODULES 5 REC Solar 400 Watt Model # REC400AA Pure INVERTER INVERTER TYPE: Micro: 5 EnphaselQ7A Model # IQ7A-72-2-US(240V) DATE.- 071 b fl2Ys��Vgl Project NaineQ No. 74200 Jeremy,Levine z Pro ert Adr '4 414 E P' i Santa Ana 2 Q Project. PV SYSTEM Scale: AS INDICATED D 9.0 STRUCTURAL REVIEW ONLY STRUCTURAL REVIEW ONLY Sept 3, 2025 To Whom It May Concern: I, Matthew Hoyt, the legal homeowner of the property located at 414 Pine St. Unit B Santa Ana, CA 92701, USA hereby authorize AWS Electrical & Solar Inc. to act on my behalf in connection with the installation of a solar photovoltaic system at the above-mentioned property, including obtaining permits, submitting applications, coordinating inspections, and performing all related work necessary to complete the project. I confirm that I am the legal owner of the property and grant AWS Electrical & Solar Inc full permission to carry out the work as described. Customer Name: Signature: Date: Company Name: AWS Electrical & Solar Inc State License No: 901196 Print Name: Signature: Date: Docusign Envelope ID: B3DB1206-1647-4E26-99F8-56FA6FE35B91 9/3/2025 Frank Florin Muntean 9/3/2025 Matthew Hoyt Certificate Of Completion Envelope Id: B3DB1206-1647-4E26-99F8-56FA6FE35B91 Status: Completed Subject: Complete with Docusign: Matthew Hoyt- HO Authorization Letter.pdf Source Envelope: Document Pages: 1 Signatures: 2 Envelope Originator: Certificate Pages: 5 Initials: 0 Frank Florin Muntean AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) 11750 Roscoe Blvd Ste 7 Sun Valley, CA 91352 fm@aws-solar.com IP Address: 216.247.17.49 Record Tracking Status: Original 9/3/2025 2:40:56 PM Holder: Frank Florin Muntean fm@aws-solar.com Location: DocuSign Signer Events Signature Timestamp Frank Florin Muntean fm@aws-solar.com Project Manager AWS Electrical & Solar Inc. Security Level: Email, Account Authentication (None) Signature Adoption: Pre-selected Style Using IP Address: 216.247.17.49 Sent: 9/3/2025 2:46:48 PM Viewed: 9/3/2025 2:47:03 PM Signed: 9/3/2025 2:47:14 PM Electronic Record and Signature Disclosure: Accepted: 4/21/2025 4:24:13 PM ID: 1d3402d4-fb05-4488-a057-46d6223f6396 Matthew Hoyt Matthew.p.hoyt@gmail.com Manager Kedham Security Level: Email, Account Authentication (None) Signature Adoption: Uploaded Signature Image Using IP Address: 75.83.76.63 Sent: 9/3/2025 2:46:48 PM Viewed: 9/3/2025 2:47:12 PM Signed: 9/3/2025 2:47:21 PM Electronic Record and Signature Disclosure: Accepted: 9/3/2025 2:47:12 PM ID: 1d6392ba-f140-4432-b45f-7ad17a15f800 In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 9/3/2025 2:46:48 PM Envelope Summary Events Status Timestamps Certified Delivered Security Checked 9/3/2025 2:47:12 PM Signing Complete Security Checked 9/3/2025 2:47:21 PM Completed Security Checked 9/3/2025 2:47:21 PM Payment Events Status Timestamps Electronic Record and Signature Disclosure ELECTRONIC RECORD AND SIGNATURE DISCLOSURE From time to time, AWS Electrical & Solar Inc. (we, us or Company) may be required by law to provide to you certain written notices or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures electronically through the DocuSign, Inc. (DocuSign) electronic signing system. Please read the information below carefully and thoroughly, and if you can access this information electronically to your satisfaction and agree to these terms and conditions, please confirm your agreement by clicking the ‘I agree’ button at the bottom of this document. Getting paper copies At any time, you may request from us a paper copy of any record provided or made available electronically to you by us. You will have the ability to download and print documents we send to you through the DocuSign system during and immediately after signing session and, if you elect to create a DocuSign signer account, you may access them for a limited period of time (usually 30 days) after such documents are first sent to you. After such time, if you wish for us to send you paper copies of any such documents from our office to you, you will be charged a $0.00 per-page fee. You may request delivery of such paper copies from us by following the procedure described below. Withdrawing your consent If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and disclosures electronically is described below. Consequences of changing your mind If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can complete certain steps in transactions with you and delivering services to you because we will need first to send the required notices or disclosures to you in paper format, and then wait until we receive back from you your acknowledgment of your receipt of such paper notices or disclosures. To indicate to us that you are changing your mind, you must withdraw your consent using the DocuSign ‘Withdraw Consent’ form on the signing page of a DocuSign envelope instead of signing it. This will indicate to us that you have withdrawn your consent to receive required notices and disclosures electronically from us and you will no longer be able to use the DocuSign system to receive required notices and consents electronically from us or to sign electronically documents from us. All notices and disclosures will be sent to you electronically Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you through the DocuSign system all required notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the disclosures and notices electronically or in paper format through the paper mail delivery system. If you do not agree with this process, please let us know as described below. Please also see the paragraph immediately above that describes the consequences of your electing not to receive delivery of the notices and disclosures Electronic Record and Signature Disclosure created on: 1/30/2016 3:34:52 PM Parties agreed to: Frank Florin Muntean, Matthew Hoyt electronically from us. How to contact AWS Electrical & Solar Inc.: You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as follows: To contact us by email send messages to: fm@awses.com To advise AWS Electrical & Solar Inc. of your new e-mail address To let us know of a change in your e-mail address where we should send notices and disclosures electronically to you, you must send an email message to us at fm@awses.com and in the body of such request you must state: your previous e-mail address, your new e-mail address. We do not require any other information from you to change your email address.. In addition, you must notify DocuSign, Inc. to arrange for your new email address to be reflected in your DocuSign account by following the process for changing e-mail in the DocuSign system. To request paper copies from AWS Electrical & Solar Inc. To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically, you must send us an e-mail to fm@awses.com and in the body of such request you must state your e-mail address, full name, US Postal address, and telephone number. We will bill you for any fees at that time, if any. To withdraw your consent with AWS Electrical & Solar Inc. To inform us that you no longer want to receive future notices and disclosures in electronic format you may: i. decline to sign a document from within your DocuSign session, and on the subsequent page, select the check-box indicating you wish to withdraw your consent, or you may; ii. send us an e-mail to fm@awses.com and in the body of such request you must state your e-mail, full name, US Postal Address, and telephone number. We do not need any other information from you to withdraw consent.. The consequences of your withdrawing consent for online documents will be that transactions may take a longer time to process.. Required hardware and software Operating Systems: Windows® 2000, Windows® XP, Windows Vista®; Mac OS® X Browsers: Final release versions of Internet Explorer® 6.0 or above (Windows only); Mozilla Firefox 2.0 or above (Windows and Mac); Safari™ 3.0 or above (Mac only) PDF Reader: Acrobat® or similar software may be required to view and print PDF files Screen Resolution: 800 x 600 minimum Enabled Security Settings: Allow per session cookies ** These minimum requirements are subject to change. If these requirements change, you will be asked to re-accept the disclosure. Pre-release (e.g. beta) versions of operating systems and browsers are not supported. Acknowledging your access and consent to receive materials electronically To confirm to us that you can access this information electronically, which will be similar to other electronic notices and disclosures that we will provide to you, please verify that you were able to read this electronic disclosure and that you also were able to print on paper or electronically save this page for your future reference and access or that you were able to e-mail this disclosure and consent to an address where you will be able to print on paper or save it for your future reference and access. Further, if you consent to receiving notices and disclosures exclusively in electronic format on the terms and conditions described above, please let us know by clicking the ‘I agree’ button below. By checking the ‘I agree’ box, I confirm that: • I can access and read this Electronic CONSENT TO ELECTRONIC RECEIPT OF ELECTRONIC RECORD AND SIGNATURE DISCLOSURES document; and • I can print on paper the disclosure or save or send the disclosure to a place where I can print it, for future reference and access; and • Until or unless I notify AWS Electrical & Solar Inc. as described above, I consent to receive from exclusively through electronic means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to me by AWS Electrical & Solar Inc. during the course of my relationship with you. Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 414 Pine St. Unit B Santa Ana, CA 92701, USA AWS Electrical & Solar Inc. 901196 Frank Muntean 818-484-3264 9/2/2025 info@aws-solar.com Expedited Permit Process for PV Systems - Micro-Inverter1 Expedited Permit Process for PV Systems Micro-Inverter The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Micro-Inverter to use with the Expedited Per- mit Process. The Standard String, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. Expedited Permit Process for PV Systems — Micro-Inverter 2 Expedited Permit Process for Small-Scale PV Systems Micro-Inverter The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. 4 4 4 Comp. Shingle chemlink IRONRIDGE XR10 281.9 9 2.81 6 100 2.81 E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 Micro-Inverter Site Plan             AWS Electrical & Solar Inc Jeremy LevineAddress: 11750 Roscoe Blvd Los Angeles, CA 91352 414 E Pine St, Unit B, Santa Ana, CA 92701 1-818-484-3264 1.74 KW 414 E Pine St, Unit B, Santa Ana, CA 92701 E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Micro-Inverter Electrical Diagram Contractor Name, Address and Phone:One-Line Standard Electrical Diagram for Micro-Inverter PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.1a SCALE NTS Date: SHEET Drawn By: Checked By: DESCRIPTION OR CONDUCTOR TYPE USE-2 or PV WIRE GEC EGC X ALL THAT APPLY EXTERIOR CABLE LISTED W/ INV. THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY NO DC GEC IF 690.35 SYSTEM THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY TAG 1 2 3 4 5 CONDUIT AND CONDUCTOR SCHEDULE COND. GAUGE MFG MFG NUMBER OF CONDUCTORS MFG Cable MFG Cable CONDUIT TYPE N/A N/A N/A SAME SAME CONDUIT SIZE N/A N/A N/A SAME SAME DESCRIPTION PV DC or AC MODULE DC/AC INVERTER (MICRO) J-BOX (IF USED) PV ARRAY AC COMB. PANEL (IF USED) GEN METER (IF USED) AC DISCONNECT (IF USED) SERVICE PANEL TAG 1 2 3 4 5 6 7 8 PART NUMBER NOTES FOR UNUSED MODULES PUT "N/A” in BLANK ABOVE 1 1 3 2 3 EQUIPMENT SCHEDULE 2 _____ MICRO-INVERTERS IN BRANCH- CIRCUIT MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC J-BOX 4 AC DISCO M BUILDING GROUNDING ELECTRODE G M UTILITY SERVICE MAIN SERVICE PANEL MAIN OCPD INVERTER OCPD 6 7 8 5 4 5 G SEE GUIDE APPENDIX D FOR INFORMATION ON MODULE AND ARRAY GROUNDING AC COMBINER PANEL G ____ MICRO-INVERTERS IN BRANCH- CIRCUIT 5 REC Solar 400W Modules 5 Enphase IQ7A Microinverters 1 1 1 30A NON-FUSED AC DISCONNECT 1 100A Main Service Panel 1 2 5 10 AWS Electrical & Solar Inc2 Address: 11750 Roscoe Blvd Los Angeles, CA 913521023/4 Jeremy Levine 10 1.74 KW1 414 E Pine St, Unit B, Santa Ana, CA 92701 1-818-484-3264 3/4 10 2 3/1 10 1 E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Contractor Name, Address and Phone:Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.2a SCALE NTS Date: SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THEREQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OUTPUT CIRCUIT OCPD(s), ONE FOR EACH MICRO-INVERTER CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ____oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE ____oC 2.) 2009 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULESWITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE.b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULESWITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix E): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE®REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNS–SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) No sign necessary since 690.51 marking on PV module covers needed information AC OUTPUT CURRENT NOMINAL AC VOLTAGE SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) Notes for Micro-Inverter Electrical Diagram Rec Solar 400 Watt REC400AA Pure 9.67 41.4 48.8 10.40 25 400 1000 Enphase IQ7A Microinverters IQ7A-72-2-US(240V) 57 240 1.45 20 9.06 240 n 75F 5 n AWS Electrical & Solar Inc Address: 11750 Roscoe Blvd Los Angeles, CA 91352 1-818-484-3264 Jeremy Levine 414 E Pine St, Unit B, Santa Ana, CA 92701 1.74 KW