HomeMy WebLinkAbout3217 S Timber St - REV 1 - PlanREV SHEET NAME SHEET SIZE SHEET NUMBER PA M E L A L A C E Y RE S I D E N C E 32 1 7 S O U T H T I M B E R S T R E E T , S A N T A A N A , C A 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:07/18/2025 DRAWN BY ESR 07/18/2025INITIAL DESIGN POWER UP SOLUTIONS LLC C10 ELECTRICAL #1113778 3855 ATHERTON RD, ROCKLIN, CA 95765 permit@gopowerupsolutions.com 08/21/2025CLIENT COMMENT A 09/08/2025CLIENT COMMENT B PROJECT DATA GENERAL NOTES VICINITY MAP PROJECT ADDRESS 3217 SOUTH TIMBER STREET, SANTA ANA, CA 92707 OWNER:PAMELA LACEY SCOPE: HOUSE PHOTO COVER SHEET PHOTOVOLTAIC ROOF MOUNT SYSTEM PV-1 COVER SHEET PV-2 PLOT PLAN WITH ROOF PLAN PV-3 ROOF PLAN & MODULES PV-4 ELECTRICAL PLAN PV-4A ELEVATION PLAN PV-5 ATTACHMENT DETAIL PV-6 ELECTRICAL LINE DIAGRAM PV-7 WIRING CALCULATION PV-8 LABELS PV-9 PLACARD PV-10 MICRO INVERTER CHART PV-11+EQUIPMENT SPECIFICATIONS PV-1 AUTHORITIES HAVING JURISDICTION: BUILDING: CITY OF SANTA ANA ZONING: CITY OF SANTA ANA UTILITY: SCE PROJECT TO COMPLY WITH THE FOLLOWING: 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA FIRE CODE ASCE 7-16 DESIGNER:ESR PARCEL ID:41028341 1.ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE WARRANTED. 2.THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH ARTICLE 690 OF THE 2022 CEC. 3.THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION. 4.ALL CONDUCTORS OF A CIRCUIT, INCLUDING THE EGC, MUST BE INSTALLED IN THE SAME RACEWAY, OR CABLE, OR OTHERWISE RUN WITH THE PV ARRAY CIRCUIT CONDUCTORS WHEN THEY LEAVE THE VICINITY OF THE PV ARRAY. 5.WHERE METALLIC CONDUIT CONTAINING DC CONDUCTORS IS USED INSIDE THE BUILDING, IT SHALL BE IDENTIFIED AS "CAUTION: SOLAR CIRCUIT" EVERY 10FT. 6.HEIGHT OF THE AC DISCONNECT SHALL NOT EXCEED 6'-7" PER CEC CODE 240.24. 7.A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH CEC 690.47 AND 250.50 THROUGH 60 AND 250-166 SHALL BE PROVIDED. PER CEC GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE OR INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT. GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGER THAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 8.PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED NON-COMBUSTIBLE. 9.PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 10.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF THE ROOF SURFACE. 11.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH THE LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE CEC AND AHJ. 12.INVERTER(S) USED IN UNGROUNDED SYSTEM SHALL BE LISTED FOR THIS USE [ CEC 690.35(G)]. 13.THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE PERFORMED ONLY BY QUALIFIED PERSONS [ CEC 690.4(C)] 14.ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED (OR BETTER), INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. 15.ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH CEC ARTICLE 250. 16.SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH CEC 690.41. 17.PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION IN ACCORDANCE WITH CEC 690.12 18.DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LOCATION WITHIN THE PV SYSTEM EQUIPMENT OR A MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [ CEC 690.13(A)] 19.ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH CEC 690.31 20.WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER CEC 110.26(A)(1), 110.26(A)(2) AND 10.26(A)(3). 21.ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED & IDENTIFIED IN ACCORDANCE WITH UL1703 22.ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER CEC EXISTING SCOPE: 8.800 KW DC ROOF MOUNT SOLAR PV SYSTEM WITH 32 REC SOLAR: REC275TP BLK 275W PV MODULES WITH 32 EXISTING SOLAREDGE: POWER OPTIMIZERS 01 SOLAREDGE SE7600A-US (240V) INVERTER A A Signed 9/10/2025 10 MODULES-ROOF MOUNTED - 4.050 KW DC, 3.800 KW AC 3217 SOUTH TIMBER STREET, SANTA ANA, CA 92707 SHEET INDEX CODE REFERENCES 4.050 KW DC ROOF MOUNT SOLAR PV SYSTEM WITH 10 HANWHA SOLAR:EB SH Q.PEAK_DUO_BLK_ML-G10+ 405W MONO MODULES WITH 10 ENPHASE EB SH IQ8HC-72-M-DOM-US (240V) [SI1-SB] MICROINVERTERS (1) TESLA POWERWALL 3 [(1707000-XX-Y) (240V)] INTEGRATED SOLAR & BATTERY 13.5kWH [SI1-SB] DERATE MAIN BREAKER FROM 200A RATED TO 175A RSD INV ACD MSP UMCB PM 90'-4" 10 5 ' - 7 " 22'-5" 107 ' - 3 " 36 ' - 0 " BATTS 1 PLOT PLAN WITH ROOF PLAN SCALE: 1/16" = 1'-0"PV-2 REV SHEET NAME SHEET SIZE SHEET NUMBER PA M E L A L A C E Y RE S I D E N C E 32 1 7 SO U T H T I M B E R S T R E E T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:07/18/2025 DRAWN BY ESR 07/18/2025INITIAL DESIGN POWER UP SOLUTIONS LLC C10 ELECTRICAL #1113778 3855 ATHERTON RD, ROCKLIN, CA 95765 permit@gopowerupsolutions.com 08/21/2025CLIENT COMMENT A 09/08/2025CLIENT COMMENT B PROJECT DESCRIPTION: PV-2 PLOT PLAN WITH ROOF PLAN (N) ENPHASE COMBINER BOX (E) TREES (E) UTILITY METER/MAIN COMBO (OUTSIDE) (E) GATE (E) FENCE ROOF ARRAY AREA #1:- 211.20 SQ FT. (E) SOLAREDGE SE7600A-US (240V) INVERTER (E) NON-FUSED AC DISCONNECT (OUTSIDE) EXISTING ROOF (32) REC SOLAR: REC275TP BLK 275W PV MODULES WITH EXISTING SOLAREDGE: POWER OPTIMIZERS EXISTING EQUIPMENT SUMMARY 32 REC SOLAR: REC275TP BLK 275W PV MODULES 32 EXISTING SOLAREDGE: POWER OPTIMIZERS 01 SOLAREDGE SE7600A-US (240V) INVERTER (E) PV PRODUCTION METER (OUTSIDE) (E) P O O L (E) CHIMNEY EXIS T I N G DRIV E W A Y SO U T H T I M B E R S T R E E T PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E PRO P E R T Y L I N E 2-STO R Y HOUS E (N) (01) TESLA POWERWALL 3 [(1707000-XX-Y) (240V)] INTEGRATED SOLAR & BATTERY 13.5kWH [SI1-SB] (OUTSIDE) (N) RAPID SHUTDOWN SWITCH (N) TESLA BACKUP SWITCH (1624171-XX-Y) [CRD-PCS NEM] A A A Signed 9/10/2025 10 X HANWHA SOLAR: EB SH Q.PEAK_DUO_BLK_ML-G10+ 405W MONO MODULES ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES DC SYSTEM SIZE: 4.050 KW DC AC SYSTEM SIZE: 3.800 KW AC EQUIPMENT SUMMARY 10 HANWHA SOLAR: EB SH Q.PEAK_DUO_BLK_ML-G10+ 405W MONO MODULES 10 ENPHASE EB SH IQ8HC-72-M-DOM-US (240V) [SI1-SB] MICROINVERTERS 01 01 TESLA POWERWALL 3 [(1707000-XX-Y) (240V)] INTEGRATED SOLAR & BATTERY 13.5kWH [SI1-SB] ROOF #1 (10) HANWHA SOLAR: EB SH Q.PEAK_DUO_BLK_ML-G10+ 405W MONO MODULES WITH ENPHASE EB SH IQ8HC-72-M-DOM-US (240V) [SI1-SB] MICROINVERTERS RSD INV ACD MSP UMCB PM 5'- 7 " 17 ' - 4 " 3'- 0 " 6'- 0 " BAT TS MODULE TYPE, DIMENSIONS & WEIGHT 1 ROOF PLAN & MODULES PV-3 SCALE: 1/8" = 1'-0" ROOF PLAN & MODULES REV SHEET NAME SHEET SIZE SHEET NUMBER PA M E L A L A C E Y RE S I D E N C E 32 1 7 S O U T H T I M B E R S T R E E T , S A N T A A N A , C A 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:07/18/2025 DRAWN BY ESR 07/18/2025INITIAL DESIGN POWER UP SOLUTIONS LLC C10 ELECTRICAL #1113778 3855 ATHERTON RD, ROCKLIN, CA 95765 permit@gopowerupsolutions.com 08/21/2025CLIENT COMMENT A 09/08/2025CLIENT COMMENT B 74 . 0 0 " 41.1" PV-3 LEGEND UM MSP - METER/MAIN SERVICE PANEL COMBO -VENT, ATTIC FAN (ROOF OBSTRUCTION) -ROOF ATTACHMENT -RAFTER - COMBINER BOXCB BAT - BATTERY ROOF ACCESS POINT (18) SNAPNRACK, ULTRAFOOT BASE, ANCHOR (242-10058-USA) ATTACHMENTS -AC DISCONNECTACD ROOF DESCRIPTION ROOF TYPE COMP SHINGLE ROOF ROOF PITCH AZIMUTH RAFTER SIZE RAFTER SPACING #1 16°114°2"X8"24" ARRAY AREA & ROOF AREA CALC'S ROOF # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 10 211.20 426.63 50 TOTAL N(10)+E(32)778.56 2745.24 28 36" F I R E S E T B A C K 36" F I R E S E T B A C K 18 " F I R E S E T B A C K 18 " F I R E S E T B A C K (E) UTILITY METER/MAIN COMBO (OUTSIDE) (E) SOLAREDGE SE7600A-US (240V) INVERTER (E) NON-FUSED AC DISCONNECT (OUTSIDE) (E) PV PRODUCTION METER (OUTSIDE) ROOF # 1PITCH - 16°AZIM. - 114° (E) CHIMNEY EXISTING ROOF (32)REC SOLAR: REC275TP BLK 275W PV MODULES WITH EXISTING SOLAREDGE: POWER OPTIMIZERS (N) ENPHASE COMBINER BOX (N) (01) TESLA POWERWALL 3 [(1707000-XX-Y) (240V)] INTEGRATED SOLAR & BATTERY 13.5kWH [SI1-SB] (OUTSIDE) (N) RAPID SHUTDOWN SWITCH (N) TESLA BACKUP SWITCH (1624171-XX-Y) [CRD-PCS NEM] TS -TESLA BACKUP SWITCH A A Signed 9/10/2025 NUMBER OF MODULES = 10 MODULES MODULE TYPE = HANWHA SOLAR: EB SH Q.PEAK_DUO_BLK_ML-G10+ 405W MONO MODULES MODULE WEIGHT = 48.5 LBS / 22.0 KG. MODULE DIMENSIONS = 74.00" x 41.1" = 21.12 SF ROOF #1 (10) HANWHA SOLAR: EB SH Q.PEAK_DUO_BLK_ML-G10+ 405W MONO MODULES WITH ENPHASE EB SH IQ8HC-72-M-DOM-US (240V) [SI1-SB] MICROINVERTERS (N) SNAPNRACK, UR-45 RAIL, 172", MILL (232-10095-USA-EB) HANWHA SOLAR: EB SH Q.PEAK_DUO_BLK_ML-G10+ 405W MONO MODULES JB RSD INV ACD MSP UMCB PM BAT TS 1 ELECTRICAL PLAN PV-4 SCALE: 1/8" = 1'-0" ELECTRICAL PLAN REV SHEET NAME SHEET SIZE SHEET NUMBER PA M E L A L A C E Y RE S I D E N C E 32 1 7 S O U T H T I M B E R S T R E E T , S A N T A A N A , C A 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:07/18/2025 DRAWN BY ESR 07/18/2025INITIAL DESIGN POWER UP SOLUTIONS LLC C10 ELECTRICAL #1113778 3855 ATHERTON RD, ROCKLIN, CA 95765 permit@gopowerupsolutions.com 08/21/2025CLIENT COMMENT A 09/08/2025CLIENT COMMENT B PV-4 LEGEND -JUNCTION BOXJB UM MSP - METER/MAIN SERVICE PANEL COMBO - CONDUIT - COMBINER BOXCB BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULES 10 HANWHA SOLAR: EB SH Q.PEAK_DUO_BLK_ML- MICRO INVERTERS 10 ENPHASE EB SH IQ8HC-72-M-DOM-US (240V) [SI1-SB] MICROINVERTERS MICROINVERTER MLP 10 MICRO INVERTER MLP (242-10034-USA) JUNCTION BOX 1 6"X6"X4" UL LISTED, STEEL WATER TIGHT NEMA TYPE 3R, UL LISTED COMBINER BOX 1 ENPHASE IQ COMBINER X-IQ-AM1-240-5C HDK [CRD-PCS NON-EXPORT] 120/240VAC, 1ɸ, 3W 125A RATED BUS BAR, NEMA 3R SOLAR LOADS ONLY UL 1741 COMPLIANT BATTERY 1 TESLA POWERWALL 3 [(1707000-XX-Y) (240V)] INTEGRATED SOLAR & BATTERY 13.5kWH [SI1-SB] BACKUP SWITCH 1 TESLA BACKUP SWITCH (1624171-XX-Y) [CRD-PCS NEM] RAILS 5 SNAPNRACK, UR-45 RAIL, 172", MILL (232-10095-USA-EB) SPLICE 4 SPLICE KIT (242-01213-USA) MODULE CLAMPS 16 MID MODULE CLAMPS (242-02071-USA) END CLAMPS 8 END CLAMPS (242-02073-USA) ATTACHMENTS 18 SNAPNRACK, ULTRAFOOT BASE, ANCHOR (242-10058-USA) GROUND LUG 2 GROUND LUGS (242-10034-USA) BAT - BATTERY CIRCUIT #1 CIRCUIT LEGENDS CIRCUIT #2 - AC DISCONNECTACD CIRCUIT #1 (5 MODULES) (N) JUNCTION BOX (N) CONDUIT CIRCUIT #2 (5 MODULES) SO U T H T I M B E R S T R E E T (E) UTILITY METER/MAIN COMBO (OUTSIDE) (E) SOLAREDGE SE7600A-US (240V) INVERTER (E) NON-FUSED AC DISCONNECT (OUTSIDE) (E) PV PRODUCTION METER (OUTSIDE) (N) ENPHASE COMBINER BOX (N) (01) TESLA POWERWALL 3 [(1707000-XX-Y) (240V)] INTEGRATED SOLAR & BATTERY 13.5kWH [SI1-SB] (OUTSIDE) (N) RAPID SHUTDOWN SWITCH (N) TESLA BACKUP SWITCH (1624171-XX-Y) [CRD-PCS NEM] TS - TESLA BACKUP SWITCH A A Signed 9/10/2025 G10+ 405W MONO MODULES (10) ENPHASE EB SH IQ8HC-72-M-DOM-US (240V) [SI1-SB] MICROINVERTERS (E) METER MAIN COMBO (E) AC DISCONNECT (E) PV PRODUCTION METER (E) SOLAREDGE SE7600A-US (240V) INVERTER TESLA POWER WALL 3 ENPHASE COMBINER BOX ELEVATION PLAN REV SHEET NAME SHEET SIZE SHEET NUMBER PA M E L A L A C E Y RE S I D E N C E 32 1 7 SO U T H T I M B E R S T R E E T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:07/18/2025 DRAWN BY ESR 07/18/2025INITIAL DESIGN POWER UP SOLUTIONS LLC C10 ELECTRICAL #1113778 3855 ATHERTON RD, ROCKLIN, CA 95765 permit@gopowerupsolutions.com 08/21/2025CLIENT COMMENT A 09/08/2025CLIENT COMMENT B 1 ELEVATION PLAN PV-4A SCALE: NTS PV-4A NOTE: : 1. ESS MUST BE INSTALLED 3FT AWAY FROM ANY OPENING INTO THE DWELLING. 2.ALL NEW ELECTRICAL EQUIPMENT CANNOT BE WITHIN 3 RADIAL FEET TO THE GAS METER. SOUTH WEST WALL OF THE HOUSE (E) UTILITY METER/MAIN COMBO (OUTSIDE) (E) NON-FUSED AC DISCONNECT (OUTSIDE) (E) PV PRODUCTION METER (OUTSIDE) (E) SOLAREDGE SE7600A-US (240V) INVERTER (N) ENPHASE COMBINER BOX (N) (01) TESLA POWERWALL 3 [(1707000-XX-Y) (240V)] INTEGRATED SOLAR & BATTERY 13.5kWH [SI1-SB] (OUTSIDE) (N) RAPID SHUTDOWN SWITCH (N) TESLA BACKUP SWITCH (1624171-XX-Y) [CRD-PCS NEM] A Signed 9/10/2025 LESS THAN 6" REV SHEET NAME SHEET SIZE SHEET NUMBER PA M E L A L A C E Y RE S I D E N C E 32 1 7 SO U T H T I M B E R S T R E E T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:07/18/2025 DRAWN BY ESR 07/18/2025INITIAL DESIGN POWER UP SOLUTIONS LLC C10 ELECTRICAL #1113778 3855 ATHERTON RD, ROCKLIN, CA 95765 permit@gopowerupsolutions.com 08/21/2025CLIENT COMMENT A 09/08/2025CLIENT COMMENT B ATTACHMENT DETAIL PV-5 (N) PV MODULE (N) GROUNDING END (242-02073) /MID (242-02071) CLAMP (E) COMP SHINGLE ROOF (N) (1) 5/16” X 4.0" SS LAG WITH MINIMUM THREAD EMBEDMENT OF 2.5" BOLT, WIDE FLANGE, RECESSED, 5-16IN-18 X 1IN, SS (N) SNAPNRACK, UR FLIP CLAMP, TAP 2"X8" RAFTER @ 24"O.C. SEE (2/PV-5) FOR ENLARGED VIEW (N) PV MODULE (E) COMP SHINGLE ROOF 2"X8" RAFTE R @ 24" O.C. 6" 1 ATTACHMENT DETAIL PV-5 1 ATTACHMENT DETAIL PV-5 SCALE: NTS ATTACHMENT DETAIL (ENLARGED VIEW) PV-5 SCALE: NTSPV-5 SCALE: NTS 2 (N) SNAPNRACK, ULTRAFOOT BASE, ANCHOR (242-10058-USA) Signed 9/10/2025 (N) SNAP N RACK UR45 RAIL (232-10095-USA-EB) L2 L1 G -+-+ 2 -+ 1 3 ===== BRANCH TERMINATOR (ET-TERM) 1 2 JUNCTION BOX, 600V, NEMA 3R, UL LISTED BRANCH #2 -+-+ G N 15A/2P IQ GATEWAY CELL MODEM TO POI PRODUCTION CT'S 20A/2P IQ GATEWAY ENV2-IQ-AM1-240/CTs [CRD-PCS NON-EXPORT] ENPHASE IQ COMBINER BOX X-IQ-AM1-240-5 HDK [CRD-PCS NEM] 120/240VAC, 1ɸ, 3W 125A RATED BUS BAR, NEMA 3R SOLAR LOADS ONLY UL 1741 COMPLIANT PRODUCTION CTs 20A/2P L2 L1 -+-+ 2 -+ 1 3 ===== BRANCH #1 54 -+-+ L1 L2 N G 3 L2 L1 N G LOAD GN VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 10' OF UTILITY METER LINE PV AC DISCONNECT 240V, 1ɸ, 3W 60A RATED NEMA 3R L2 L1 N G = DC AC L2 L1 N G SOLAREDGE SE7600A-US (240V) INVERTER L2 L1 G (E) JUNCTION BOX, 600V, NEMA 3R, UL LISTED (E) (32) REC SOLAR: REC275TP BLK 275W MODULES EE -+ -++ -+ +++--- -+ - (E) STRING #1 -+-+ 21 3 15 16 E = = = = = = = = = = (E) SOLAREDGE: POWER OPTIMIZERS -+ -++ -+ +++--- -+ - (E) STRING #2 -+-+ 21 3 = = = = = = = = = = L2 L1 15 16 LOAD LINE L2 L2 L1 L1 PRODUCTION METER, NEMA 3R GN 54 E E G N G N N L1L2 20A/2P L2 L1 N G DC AC = CTRL RAPID SHUTDOWN SWITCH WIRING POWERWALL 3 LEADER 4 RSD CAN DC 60A/2P INTERCONNECTION REF TO 2022 CEC 705.13 (#1) POWERWALL 3 TESLA PW3 1707000-XX-Y [240V, 11.5KWh] [SI1-SB] OUTPUT: 240 VAC, 48.00A 97% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED WITH INTEGRATED TESLA SOLAR POWERWALL 3 [13.5kWh] (E) METER/MAIN PANEL COMBO, 120/240V, 1ɸ, 3W 200A RATED DC 12V/CAN WIRING 15A/2P (E) 40A/2P LOAD SIDE INTERCONNECTION AT MAIN PANEL/SUB PANEL PER ART. 705.12 BI-DIRECTIONAL UTILITY METER # 222013-157248 120/240V 1ɸ, 3-W TESLA REMOTE ENERGY METER 2X GROUND ROD AT 6' APART,GEC #6 AWG PLACED 6'-0" APART CONNECT TO COLD WATER WITHIN 5' ALL #6 CU GEC REV SHEET NAME SHEET SIZE SHEET NUMBER PA M E L A L A C E Y RE S I D E N C E 32 1 7 SO U T H T I M B E R S T R E E T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:07/18/2025 DRAWN BY ESR 07/18/2025INITIAL DESIGN POWER UP SOLUTIONS LLC C10 ELECTRICAL #1113778 3855 ATHERTON RD, ROCKLIN, CA 95765 permit@gopowerupsolutions.com 08/21/2025CLIENT COMMENT A 09/08/2025CLIENT COMMENT B ELECTRICAL LINE DIAGRAM 1 ELECTRICAL LINE DIAGRAM PV-6 SCALE: NTS PV-6 GROUNDING & GENERAL NOTES: 1. A SECOND FACILITY GROUNDING ELECTRODE IS NOT REQUIRED PER [CEC 690.47(C)(3)] 2. PV INVERTER IS UNGROUNDED, TRANSFORMER-LESS TYPE. 3. DC GEC AND AC EGC TO REMAIN UNSPLICED, OR SPLICED TO EXISTING ELECTRODE 4. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. 5. JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - JUNCTION BOX DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 6. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT. 7. RACEWAYS AND CABLES EXPOSED TO SUNLIGHT ON ROOFTOPS SHOULD BE INSTALLED MORE THAN 7/8" ABOVE THE ROOF USING CONDUIT SUPPORTS. 8. ALL NEW SERVICE INSTALLATIONS AND REPLACEMENTS REQUIRE A SURGE-PROTECTIVE DEVICE (SPD) IN ACCORDANCE WITH [CEC 230.67]. THE SPD SHALL BE TYPE 1 OR TYPE 2 AND IS REQUIRED TO BE AN INTEGRAL PART OF THE SERVICE EQUIPMENT OR LOCATED IMMEDIATELY ADJACENT THERETO. INTERCONNECTION NOTES: 1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE DETERMINED IN ACCORDANCE WITH [CEC 705.12], AND [CEC 690.64]. 2. GROUND FAULT PROTECTION IN ACCORDANCE WITH [CEC 215.9], [CEC 230.95] AND [CEC 690.5] 3. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. 4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER. DISCONNECT NOTES: 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH RACKING NOTES: 1. BOND AT EVERY ROW WITH DYNOBOND QTY CONDUCTOR INFORMATION CONDUIT TYPE CONDUIT SIZE (4)#12AWG -ENPHASE Q CABLE (L1 & L2 NO NEUTRAL)N/A N/A (4)#10AWG -CU,THWN-2 L1 & L2 EMT OR LFMC 3/4"(1)#8AWG -CU,THWN-2 GND (2)#10AWG -CU,THWN-2 L1 & L2 EMT OR PVC 3/4" (1)#8AWG -CU,THWN-2 GND 1 2 3 DYNOBOND (2) BRANCH CIRCUITS OF 05 MODULES ARE CONNECTED IN PARALLEL INSTALLER / ELECTRICIAN NOTE: EC IS TO MEASURE VOLTAGE BEFORE STARTING WORK. IF RESULT IS ANY OTHER VOLTAGE MEASURED THAN 120/240V IS OBSERVED, DO NOT PROCEED. CONTACT ENGINEER (2)#6AWG -CU,THWN-2 L1 & L2 EMT OR PVC(1)#6AWG -CU,THWN-2 N (1)#8AWG -CU,THWN-2 GND 4 3/4" EXISTING SYSTEM 8.800 KW DC ROOF MOUNT SOLAR PV SYSTEM WITH 32 REC SOLAR: REC275TP BLK 275W PV MODULES WITH 32 EXISTING SOLAREDGE: POWER OPTIMIZERS 01 SOLAREDGE SE7600A-US (240V) INVERTER POWER CONTROL SYSTEM (PCS): INVERTER : TESLA:1707000-XX-Y 1) ENERGY STORAGE SYSTEM: TESLA:POWERWALL 3 2) ENABLE PCS SETPOINTS: 1) 160A - MAXIMUM TOTAL CURRENT ON THE CONTROLLED PANEL 1) 0A - FAIL SAFE GENERATION BACKFEED CURRENT SUPPLY (120% COMPLIANT) NOTE : PRODUCERS STORAGE DEVICE(S) WILL NOT CAUSE THE HOST LOAD TO EXCEED ITS NORMAL PEAK DEMAND. NORMAL PEAK DEMAND IS DEFINED AS THE HIGHEST AMOUNT OF POWER REQUIRED FROM THE DISTRIBUTION SYSTEM BY PRODUCERS COMPLETE FACILITIES WITHOUT THE INFLUENCE OR USE OF THE ENERGY STORAGE DEVICE(S) (1)#10AWG -CU,THWN-2 N A NOTE : USE QUAD BREAKERS TO MAKE ROOM FOR SOLAR BREAKER Signed 9/10/2025 (10) HANWHA SOLAR: EB SH Q.PEAK_DUO_BLK_ML-G10+ 405W MONO MODULES WITH (10) ENPHASE EB SH IQ8HC-72-M-DOM-US (240V) [SI1-SB] MICROINVERTERS (01) TESLA POWERWALL 3 [(1707000-XX-Y) (240V)] INTEGRATED SOLAR & BATTERY 13.5KWH [SI1-SB] (1) TESLA BACKUP SWITCH (1624171-XX-Y) [CRD-PCS NEM] MAXIMUM OUTPUT CURRENT FROM THIS SYSTEM TOWARDS THE MAIN PANEL IS CONTROLLED PCS CONTROLLED CURRENT IS 140A CONTINUOUS (10) HANWHA SOLAR:EB SH Q.PEAK_DUO_BLK_ML-G10+ 400W MONO MODULES (10) ENPHASE EB SH IQ8HC-72-M-DOM-US (240V) [SI1-SB] MICROINVERTERS LOCATED UNDER EACH PANEL (N) MAIN BREAKER 240 V, 175A/2P DERATE MAIN BREAKER FROM 200A RATED TO 175A DC SYSTEM SIZE: 4.050 KW DC AC SYSTEM SIZE: 3.800 KW AC REV SHEET NAME SHEET SIZE SHEET NUMBER PA M E L A L A C E Y RE S I D E N C E 32 1 7 SO U T H T I M B E R S T R E E T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:07/18/2025 DRAWN BY ESR 07/18/2025INITIAL DESIGN POWER UP SOLUTIONS LLC C10 ELECTRICAL #1113778 3855 ATHERTON RD, ROCKLIN, CA 95765 permit@gopowerupsolutions.com 08/21/2025CLIENT COMMENT A 09/08/2025CLIENT COMMENT B WIRING CALCULATIONS PV-7 PERCENT OF VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT .80 4-6 .70 7-9 .50 10-20 AMBIENT TEMPERATURE SPECS RECORD LOW TEMP 3° AMBIENT TEMP (HIGH TEMP 2%)37° MODULE TEMPERATURE COEFFICIENT OF Voc -0.27%/K ELECTRICAL NOTES 1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.ALL CONDUCTORS SHALL BE RATED UPTO 600V FOR RESIDENTIAL AND 1000V FOR COMMERCIAL AND 90 DEGREE C WET ENVIRONMENT. 3.WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH CEC 110.26. 5.DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.WHERE SIZES OF SOLADECK, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.TEMPERATURE RATINGS OF ALL CONDUCTORS, TERMINATIONS, BREAKERS, OR OTHER DEVICES ASSOCIATED WITH THE SOLAR PV SYSTEM SHALL BE RATED FOR AT LEAST 75 DEGREE C. MAX INPUT POWER 320W-540W NOMINAL AC VOLTAGE RATING 240V/ 211-264V MAX AC CURRENT 1.58A MAX MODULES PER CIRCUIT 10 (SINGLE PHASE) MAX OUTPUT POWER 380 VA SOLAR MODULE SPECIFICATIONS IMP 10.77A VOC 45.30V ISC 11.14A TEMP. COEFF. VOC -0.27%/K MODULE DIMENSION 74.00"L x 41.1"W x 1.26"D (In Inch) A Signed 9/10/2025 405W MODULE VMP 37.13V HANWHA SOLAR: EB SH Q.PEAK_DUO_BLK_ML-G10+ MANUFACTURER / MODEL #EB SH IQ8HC-72-M-DOM-US MICRO INVERTERS INVERTER SPECIFICATIONS MANUFACTURER / MODEL # MIN/MAX DC VOLT RATING 22V MIN/ 58V MAX REV SHEET NAME SHEET SIZE SHEET NUMBER PA M E L A L A C E Y RE S I D E N C E 32 1 7 SO U T H T I M B E R S T R E E T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:07/18/2025 DRAWN BY ESR 07/18/2025INITIAL DESIGN POWER UP SOLUTIONS LLC C10 ELECTRICAL #1113778 3855 ATHERTON RD, ROCKLIN, CA 95765 permit@gopowerupsolutions.com 08/21/2025CLIENT COMMENT A 09/08/2025CLIENT COMMENT B LABELS PV-8 WARNING: PHOTOVOLTAIC POWER SOURCE EVERY 10' ON CONDUIT & ENCLOSURES LABEL LOCATION: EMT/CONDUIT RACEWAY SOLADECK / JUNCTION BOX CODE REF: 2022 CEC 690.31 (D)(2) LABEL- 1: TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING! ELECTRIC SHOCK HAZARD LABEL LOCATION: AC DISCONNECT INVERTER MAIN SERVICE PANEL SUBPANEL MAIN SERVICE DISCONNECT CODE REF: 2022CEC 690.13(B) LABEL- 2: !WARNING TRI POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM THIRD SOURCE IS ESS SYSTEM LABEL LOCATION: PRODUCTION METER UTILITY METER MAIN SERVICE PANEL SUBPANEL CODE REF: 2022 CEC 705.12(D)(3) & 2022 CEC 690.59 LABEL- 3: TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL WARNING! LABEL LOCATION: MAIN SERVICE PANEL SUBPANEL MAIN SERVICE DISCONNECT COMBINER CODE REF: 2022 CEC 110.27(C) & OSHA 1910.145 (f) (7) LABEL- 4: LABEL LOCATION: MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK-FED) SUBPANEL (ONLY IF SOLAR IS BACK-FED) CODE REF: 2022 CEC 705.12(B)(3)(2) LABEL- 5: WARNING POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE ! SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS LABEL LOCATION: AC DISCONNECT CODE REF: 2022 CFC 2022 1205.4.1(1) & 2022 CEC 690.56(C) LABEL- 6: RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION: AC DISCONNECT CODE REF: 2022 CEC 690.(C) (2) LABEL- 7: MAIN PHOTOVOLTAIC SYSTEM DISCONNECT LABEL LOCATION: MAIN SERVICE DISCONNECT (ONLY IF MAIN SERVICE DISCONNECT IS USED) CODE REF: 2022 CEC 690.13(B) LABEL- 8: PCS CONTROLLED CURRENT SETTING 160 A THE MAXIMUM OUTPUT CURRENT FROM THIS SYSTEM TOWARDS THE MAIN PANEL IS CONTROLLED ELECTRONICALLY. REFER TO THE MANUFACTURER'S INSTRUCTION FOR MORE INFORMATION. LABEL LOCATION: MAIN SERVICE PANEL CODE REF: 2022 CEC 705.13 LABEL- 9: WARNING: THIS SENSOR IS PART OF A POWER CONTROL SYSTEM. DO NOT REMOVE. REPLACE ONLY WITH THE SAME TYPE AND RATING. LABEL LOCATION: AROUND THE CT WIRE BY CLAMP CODE REF: UL 1741, SECTION 206.3 LABEL- 10: A Signed 9/10/2025 PCS CONTROLLED CURRENT SETTING 140 A THE MAIN BREAKER HAS BEEN DOWNSIZED TO 175 AMPS, NO UPSIZING LABEL LOCATION: MAIN SERVICE PANEL LABEL- 11: JB RSD INVACDMSPUMCB PMBATTS REV SHEET NAME SHEET SIZE SHEET NUMBER PA M E L A L A C E Y RE S I D E N C E 32 1 7 S O U T H T I M B E R S T R E E T , S A N T A A N A , C A 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:07/18/2025 DRAWN BY ESR 07/18/2025INITIAL DESIGN POWER UP SOLUTIONS LLC C10 ELECTRICAL #1113778 3855 ATHERTON RD, ROCKLIN, CA 95765 permit@gopowerupsolutions.com 08/21/2025CLIENT COMMENT A 09/08/2025CLIENT COMMENT B PLACARD 3217 SOUTH TIMBER STREET, SANTA ANA, CA 92707 PV-9 DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: CEC 690.56(A)(B), [CEC 705.10]) LABELING NOTES: 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT CEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2. LABELING REQUIREMENTS BASED ON THE 2022 CEC, OSHA STANDARD 19010.145, ANSI Z535. 3.MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [CEC 110.21] CAUTION: MULTIPLE SOURCES OF POWER (N) PV ARRAY (N) JUNCTION BOX (E) PV ARRAY (E) UTILITY METER/MAIN COMBO (OUTSIDE) (E) SOLAREDGE SE7600A-US (240V) INVERTER (E) NON-FUSED AC DISCONNECT (OUTSIDE) (E) PV PRODUCTION METER (OUTSIDE) (N) ENPHASE COMBINER BOX (N) (01) TESLA POWERWALL 3 [(1707000-XX-Y) (240V)] INTEGRATED SOLAR & BATTERY 13.5kWH [SI1-SB] (OUTSIDE) (N) RAPID SHUTDOWN SWITCH (N) TESLA BACKUP SWITCH (1624171-XX-Y) [CRD-PCS NEM] A Signed 9/10/2025 REV SHEET NAME SHEET SIZE SHEET NUMBER PA M E L A L A C E Y RE S I D E N C E 32 1 7 SO U T H T I M B E R S T R E E T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:07/18/2025 DRAWN BY ESR 07/18/2025INITIAL DESIGN POWER UP SOLUTIONS LLC C10 ELECTRICAL #1113778 3855 ATHERTON RD, ROCKLIN, CA 95765 permit@gopowerupsolutions.com 08/21/2025CLIENT COMMENT A 09/08/2025CLIENT COMMENT B MICRO INVERTER CHART MICRO INVERTER CHART 1-10 2 3 4 11-20 21-30 31-40 41-50 51-60 5 61-70 6 7 8 9 10 1 PV-10 Signed 9/10/2025 REV SHEET NAME SHEET SIZE SHEET NUMBER PA M E L A L A C E Y RE S I D E N C E 32 1 7 SO U T H T I M B E R S T R E E T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:07/18/2025 DRAWN BY ESR 07/18/2025INITIAL DESIGN POWER UP SOLUTIONS LLC C10 ELECTRICAL #1113778 3855 ATHERTON RD, ROCKLIN, CA 95765 permit@gopowerupsolutions.com 08/21/2025CLIENT COMMENT A 09/08/2025CLIENT COMMENT B EQUIPMENT SPECIFICATION PV-11 A Signed 9/10/2025 REV SHEET NAME SHEET SIZE SHEET NUMBER PA M E L A L A C E Y RE S I D E N C E 32 1 7 SO U T H T I M B E R S T R E E T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:07/18/2025 DRAWN BY ESR 07/18/2025INITIAL DESIGN POWER UP SOLUTIONS LLC C10 ELECTRICAL #1113778 3855 ATHERTON RD, ROCKLIN, CA 95765 permit@gopowerupsolutions.com 08/21/2025CLIENT COMMENT A 09/08/2025CLIENT COMMENT B EQUIPMENT SPECIFICATION PV-12 Signed 9/10/2025 REV SHEET NAME SHEET SIZE SHEET NUMBER PA M E L A L A C E Y RE S I D E N C E 32 1 7 SO U T H T I M B E R S T R E E T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:07/18/2025 DRAWN BY ESR 07/18/2025INITIAL DESIGN POWER UP SOLUTIONS LLC C10 ELECTRICAL #1113778 3855 ATHERTON RD, ROCKLIN, CA 95765 permit@gopowerupsolutions.com 08/21/2025CLIENT COMMENT A 09/08/2025CLIENT COMMENT B EQUIPMENT SPECIFICATION PV-13 Signed 9/10/2025 REV SHEET NAME SHEET SIZE SHEET NUMBER PA M E L A L A C E Y RE S I D E N C E 32 1 7 SO U T H T I M B E R S T R E E T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:07/18/2025 DRAWN BY ESR 07/18/2025INITIAL DESIGN POWER UP SOLUTIONS LLC C10 ELECTRICAL #1113778 3855 ATHERTON RD, ROCKLIN, CA 95765 permit@gopowerupsolutions.com 08/21/2025CLIENT COMMENT A 09/08/2025CLIENT COMMENT B EQUIPMENT SPECIFICATION PV-14 Signed 9/10/2025 REV SHEET NAME SHEET SIZE SHEET NUMBER PA M E L A L A C E Y RE S I D E N C E 32 1 7 SO U T H T I M B E R S T R E E T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:07/18/2025 DRAWN BY ESR 07/18/2025INITIAL DESIGN POWER UP SOLUTIONS LLC C10 ELECTRICAL #1113778 3855 ATHERTON RD, ROCKLIN, CA 95765 permit@gopowerupsolutions.com 08/21/2025CLIENT COMMENT A 09/08/2025CLIENT COMMENT B EQUIPMENT SPECIFICATION PV-15 A Signed 9/10/2025 REV SHEET NAME SHEET SIZE SHEET NUMBER PA M E L A L A C E Y RE S I D E N C E 32 1 7 SO U T H T I M B E R S T R E E T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:07/18/2025 DRAWN BY ESR 07/18/2025INITIAL DESIGN POWER UP SOLUTIONS LLC C10 ELECTRICAL #1113778 3855 ATHERTON RD, ROCKLIN, CA 95765 permit@gopowerupsolutions.com 08/21/2025CLIENT COMMENT A 09/08/2025CLIENT COMMENT B EQUIPMENT SPECIFICATION PV-16 A Signed 9/10/2025 REV SHEET NAME SHEET SIZE SHEET NUMBER PA M E L A L A C E Y RE S I D E N C E 32 1 7 SO U T H T I M B E R S T R E E T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:07/18/2025 DRAWN BY ESR 07/18/2025INITIAL DESIGN POWER UP SOLUTIONS LLC C10 ELECTRICAL #1113778 3855 ATHERTON RD, ROCKLIN, CA 95765 permit@gopowerupsolutions.com 08/21/2025CLIENT COMMENT A 09/08/2025CLIENT COMMENT B EQUIPMENT SPECIFICATION PV-17 Signed 9/10/2025 REV SHEET NAME SHEET SIZE SHEET NUMBER PA M E L A L A C E Y RE S I D E N C E 32 1 7 SO U T H T I M B E R S T R E E T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:07/18/2025 DRAWN BY ESR 07/18/2025INITIAL DESIGN POWER UP SOLUTIONS LLC C10 ELECTRICAL #1113778 3855 ATHERTON RD, ROCKLIN, CA 95765 permit@gopowerupsolutions.com 08/21/2025CLIENT COMMENT A 09/08/2025CLIENT COMMENT B EQUIPMENT SPECIFICATION PV-18 Signed 9/10/2025 REV SHEET NAME SHEET SIZE SHEET NUMBER PA M E L A L A C E Y RE S I D E N C E 32 1 7 SO U T H T I M B E R S T R E E T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:07/18/2025 DRAWN BY ESR 07/18/2025INITIAL DESIGN POWER UP SOLUTIONS LLC C10 ELECTRICAL #1113778 3855 ATHERTON RD, ROCKLIN, CA 95765 permit@gopowerupsolutions.com 08/21/2025CLIENT COMMENT A 09/08/2025CLIENT COMMENT B EQUIPMENT SPECIFICATION PV-19 Signed 9/10/2025 REV SHEET NAME SHEET SIZE SHEET NUMBER PA M E L A L A C E Y RE S I D E N C E 32 1 7 SO U T H T I M B E R S T R E E T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:07/18/2025 DRAWN BY ESR 07/18/2025INITIAL DESIGN POWER UP SOLUTIONS LLC C10 ELECTRICAL #1113778 3855 ATHERTON RD, ROCKLIN, CA 95765 permit@gopowerupsolutions.com 08/21/2025CLIENT COMMENT A 09/08/2025CLIENT COMMENT B EQUIPMENT SPECIFICATION PV-20 Signed 9/10/2025 REV SHEET NAME SHEET SIZE SHEET NUMBER PA M E L A L A C E Y RE S I D E N C E 32 1 7 SO U T H T I M B E R S T R E E T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:07/18/2025 DRAWN BY ESR 07/18/2025INITIAL DESIGN POWER UP SOLUTIONS LLC C10 ELECTRICAL #1113778 3855 ATHERTON RD, ROCKLIN, CA 95765 permit@gopowerupsolutions.com 08/21/2025CLIENT COMMENT A 09/08/2025CLIENT COMMENT B EQUIPMENT SPECIFICATION PV-21 Signed 9/10/2025 REV SHEET NAME SHEET SIZE SHEET NUMBER PA M E L A L A C E Y RE S I D E N C E 32 1 7 SO U T H T I M B E R S T R E E T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:07/18/2025 DRAWN BY ESR 07/18/2025INITIAL DESIGN POWER UP SOLUTIONS LLC C10 ELECTRICAL #1113778 3855 ATHERTON RD, ROCKLIN, CA 95765 permit@gopowerupsolutions.com 08/21/2025CLIENT COMMENT A 09/08/2025CLIENT COMMENT B EQUIPMENT SPECIFICATION PV-22 Signed 9/10/2025 REV SHEET NAME SHEET SIZE SHEET NUMBER PA M E L A L A C E Y RE S I D E N C E 32 1 7 SO U T H T I M B E R S T R E E T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:07/18/2025 DRAWN BY ESR 07/18/2025INITIAL DESIGN POWER UP SOLUTIONS LLC C10 ELECTRICAL #1113778 3855 ATHERTON RD, ROCKLIN, CA 95765 permit@gopowerupsolutions.com 08/21/2025CLIENT COMMENT A 09/08/2025CLIENT COMMENT B EQUIPMENT SPECIFICATION PV-23 Signed 9/10/2025 REV SHEET NAME SHEET SIZE SHEET NUMBER PA M E L A L A C E Y RE S I D E N C E 32 1 7 SO U T H T I M B E R S T R E E T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:07/18/2025 DRAWN BY ESR 07/18/2025INITIAL DESIGN POWER UP SOLUTIONS LLC C10 ELECTRICAL #1113778 3855 ATHERTON RD, ROCKLIN, CA 95765 permit@gopowerupsolutions.com 08/21/2025CLIENT COMMENT A 09/08/2025CLIENT COMMENT B EQUIPMENT SPECIFICATION PV-24 Signed 9/10/2025