HomeMy WebLinkAbout1621 S Diamond St Unit #2 - Plan (2)4' 17 ' 11' 3'57' 12 0 ' 12 0 ' 57' 16' DIAMOND ADU 1621 S DIAMOND ST, UNIT 2 SANTA ANA, CA 92704 PV-1 DATE: 01/13/2026 REV E AHJ: APN: 40824215 SANTA ANA CITYSCALE: SHEET SIZE: 11" x 17" TEMPLATE V2.0 PREPARED BY: HIGH LINE DESIGNS SCOTT TOYAMA STARS CONSTRUCTION SERVICES INC 6022 WESTERN AVE BUENA PARK, CA 90621 714.262.3929 HUY THIEU NGUYEN C10 #833971 1/16" = 1'-0" COVER SHEET SITE PLAN ·(08) LONGI LR5-54HPB-400M MODULES ·(08) TIGO TS4-A-F RAPID SHUTDOWN ·(01) GROWATT MIN 6000TL-XH-US (240V) INVERTER ·(01) NON-FUSED AC DISCONNECT ALL WORK TO COMPLY WITH: ·2022 CALIFORNIA ELECTRICAL CODE ·2022 CALIFORNIA RESIDENTIAL CODE ·2022 CALIFORNIA FIRE CODE ·2022 CALIFORNIA BUILDING CODE TABLE OF CONTENTS PV-1 COVER SHEET PV-2 ROOF PLAN & MODULES PV-2A STRINGING PAGE PV-3+ ATTACHMENT DETAILS PV-4 SINGLE-LINE DIAGRAM PV-4A ELECTRICAL CALCULATIONS PV-5 LABELS & PLACARD PV-6+ EQUIPMENT DATASHEETS SITE DETAILS ASHRAE MIN TEMP ASHRAE 2% HIGH TEMP BUILDING OCCUPANCY TYPE OF CONSTRUCTION SPRINKLERS SYSTEM PER NFPA 13D # OF STORIES WIND SPEED (ASCE 7-16) WIND EXPOSURE RISK CATEGORY GROUND SNOW LOAD SQUARE FOOTAGE UTILITY 2°C 31°C R-3 V-B NO 1 95 MPH B II 0 PSF 1500 SQ FT SCE VICINITY MAP GOVERNING CODES TOTAL PV SIZE: 3.200 KW DC, 2.902 KW CEC AC SCOPE OF WORK INSTALL A ROOF-MOUNTED PV SYSTEM: GENERAL NOTES ·ALL WORK SHALL CONFORM TO APPLICABLE BUILDING, ELECTRICAL CODE AND ANY LOCALLY ADOPTED ORDINANCES. ·DRAWINGS ARE DIAGRAMMATIC, SITE CONDITIONS SHALL PREVAIL. IF NO SCALE IS GIVEN, DRAWINGS ARE NOT TO SCALE. ALL DIMENSIONS SHALL BE VERIFIED BY THE CONTRACTOR IN THE FIELD UPON COMMENCEMENT OF CONSTRUCTION. ·ALL CONDUIT AND WIRE RUNS ARE DIAGRAMMATIC, SUBJECT TO FIELD CONDITIONS ROUTING OF RACEWAYS SHALL BE FINALIZED BY THE CONTRACTOR. IF THE DISTANCES FOR WIRE RUNS ARE DIFFERENT THAN AS SHOWN, THE CONTRACTOR SHALL NOTIFY THE DESIGN TEAM TO VALIDATE THE WIRE SIZE. ·ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED TESTING LABORATORY AND INSTALLED PER THE LISTING AND MANUFACTURER'S REQUIREMENTS. ·ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH REQUIRED ACCESS AND WORKING CLEARANCES PER CEC ARTICLE 110. ·ALL NEW MAIN SERVICE PANELS AND SUBPANELS WILL HAVE APPROPRIATE FIELD IDENTIFICATION PER CEC 408.4. ·ALL EQUIPMENT WILL BE INSTALLED WHERE IT IS NOT EXPOSED TO PHYSICAL DAMAGE PER CEC 110.27(B) PR O P E R T Y L I N E S DIAMOND ST FRONT OF HOUSE W P O M O N A S T 10"5'-7" 18 " F I R E S E T B A C K 18 " F I R E S E T B A C K 8' - 5 " 18 ' - 8 " 8' - 5 " 9'-0"11'-2"9'-8" 1' - 6 " 5" JB PV-2 DATE: 01/13/2026 REV E AHJ: APN: 40824215 SANTA ANA CITYSCALE: SHEET SIZE: 11" x 17" TEMPLATE V2.0 PREPARED BY: HIGH LINE DESIGNS SCOTT TOYAMA STARS CONSTRUCTION SERVICES INC 6022 WESTERN AVE BUENA PARK, CA 90621 714.262.3929 HUY THIEU NGUYEN C10 #833971 1/14" = 1'-0" ROOF PLAN & MODULES PV ROOF COVERAGE (E) PV AREA [SQ FT] (N) PV AREA [SQ FT] TOTAL PV AREA [SQ FT] TOTAL ROOF AREA [SQ FT] PERCENTAGE COVERED BY PV 0 160.26 160.26 937.17 17% ROOF DESCRIPTION ROOF ROOF TILT AZIMUTH ROOF MATERIAL RAFTER SIZE RAFTER SPACING MAX RAFTER SPAN #1 18° 180°COMP SHINGLE 2" X 6"16" O.C. 7'-0" #2 18° 270°COMP SHINGLE 2" X 6"16" O.C. 7'-0" LEGEND JB - JUNCTION BOX - RAFTER OR TRUSS - ROOF OBSTRUCTION - ROOF ATTACHMENT - 36" FIRE SETBACKS / PATHWAYS - ACCESS POINTX S DIAMOND ST (08) LONGI LR5-54HPB-400M MODULES WITH (08)TIGO TS4-A-F RAPID SHUTDOWN (N) IRONRIDGE XR10 RAIL (16) IRONRIDGE FLASHFOOT 2 ATTACHMENTS WITH MAX 64" O.C. SPAN (N) EMT CONDUIT ROOF #1 (E) MAIN SERVICE PANEL (RAPID SHUTDOWN INITIATION DEVICE) (E) UTILITY METER (N) GROWATT MIN 6000TL-XH-US INVERTER (INTEGRATED DC DISCONNECT) X W P O M O N A S T X (N) NON-FUSED AC DISCONNECT X ROOF #2 (E) ADU SUBPANEL (E) MAIN HOUSE SUBPANEL 1. PRIOR TO COMMENCEMENT OF WORK, THE CONTRACTOR SHALL VERIFY THE FRAMI SIZES, SPACINGS, AND SPANS NOTED IN THE STAMPED PLANS AND ACCOMPANYING CALCULATIONS AND NOTIFY THE ENGINEER OF RECORD OF ANY DISCREPANCIES PRIOR TO STARTING CONSTRUCTION. 2. THESE PLANS ARE STAMPED FOR STRUCTURAL CODE COMPLIANCE OF THE RO FRAMING SUPPORTING THE PROPOSED PV INSTALLATION REFERENCED ONLY. THESE PLANS ARE NOT STAMPED FOR WATER LEAKAGE. PV MODULES, RACKING, AND ATTACHMENT COMPONENTS MUST FOLLOW MANUFACTURER GUIDELINES AND REQUIREMENTS. 3. PLEASE SEE THE ACCOMPANYING STRUCTURAL CALCULATIONS REPORT FOR DETAI REGARDING CALCULATIONS AS WELL AS LIMITS OF SCOPE OF WORK AND LIABILITY. DIAMOND ADU 1621 S DIAMOND ST, UNIT 2 SANTA ANA, CA 92704 JB PV-2A DATE: 01/13/2026 REV E AHJ: APN: 40824215 SANTA ANA CITYSCALE: SHEET SIZE: 11" x 17" TEMPLATE V2.0 PREPARED BY: HIGH LINE DESIGNS SCOTT TOYAMA STARS CONSTRUCTION SERVICES INC 6022 WESTERN AVE BUENA PARK, CA 90621 714.262.3929 HUY THIEU NGUYEN C10 #833971 1/4" = 1'-0" STRINGING PAGE S DIAMOND ST W P O M O N A S T A A B B DIAMOND ADU 1621 S DIAMOND ST, UNIT 2 SANTA ANA, CA 92704 PV MODULE (E) COMP SHINGLE IRONRIDGE FLASHFOOT 2 IRONRIDGE XR 10 RAIL (E) COMP SHINGLE IRONRIDGE XR 10 RAIL PV MODULE 5/16"X3" 304 STAINLESS STEEL COMPRESSION WASHER BLACK 4 3/4" X 5/16" WITH 2.5" MIN LAG SCREW EMBEDMENT SEE BELOW FOR ENLARGED VIEW IRONRIDGE FLASHFOOT 2 MID/END CLAMP 6" MAX PV-3 DATE: 01/13/2026 REV E AHJ: APN: 40824215 SANTA ANA CITYSCALE: SHEET SIZE: 11" x 17" TEMPLATE V2.0 PREPARED BY: HIGH LINE DESIGNS SCOTT TOYAMA STARS CONSTRUCTION SERVICES INC 6022 WESTERN AVE BUENA PARK, CA 90621 714.262.3929 HUY THIEU NGUYEN C10 #833971 ATTACHMENT DETAILS NTS DIAMOND ADU 1621 S DIAMOND ST, UNIT 2 SANTA ANA, CA 92704 (N) GROWATT MIN 6000TL-XH-US INVERTER, WITH INTEGRATED LOCKABLE DISCONNET, (240V) [SI1-SB] 42(N) NON-FUSED AC DISCONNECT, SQUARE D DU222RB 60A, 240V, NEMA 3R 3 (N) 08 - LONGI LR5-54HPB-400M MODULES STRING 1: 03 MODULES STRING 2: 05 MODULES 03 05 1 (N) JBOX, NEMA 3R (N) 08 - TIGO TS4-A-F RAPID SHUTDOWN (E) ADU SUBPANEL, 125A, 240V, NEMA 3R 705.12(B)(3)(2) 40A/2P E (E) MAIN SERVICE PANEL, 200A, 240V, NEMA 3R 705.12(B)(3)(2) (E) GROUNDING ELECTRODE 100A/2P M 100A/2P M UTILITY (E) MAIN BREAKER 100A (RAPID SHUTDOWN INITIATION DEVICE) (E) HOUSE SUBPANEL, 125A, 240V, NEMA 3R 705.12(B)(3)(3) E UTILITY METER #---- 1Ø, 3W, 240V PV-4 DATE: 01/13/2026 REV E AHJ: APN: 40824215 SANTA ANA CITYSCALE: SHEET SIZE: 11" x 17" TEMPLATE V2.0 PREPARED BY: HIGH LINE DESIGNS SCOTT TOYAMA STARS CONSTRUCTION SERVICES INC 6022 WESTERN AVE BUENA PARK, CA 90621 714.262.3929 HUY THIEU NGUYEN C10 #833971 SINGLE-LINE DIAGRAM NTS THE MAIN BREAKER IN THE MAIN SERVICE PANEL WILL INITIATE RAPID SHUTDOWN AND MEET THE REQUIREMENTS OUTLINED IN CEC 690.12. THE PV BREAKER(S) LAND IN A PANEL THAT MEETS THE PV DISCONNECT REQUIREMENTS OUTLINED IN CEC 690.13. THIS PANEL IS READILY ACCESSIBLE, AND THE PANEL ENCLOSURE IS LOCKABLE. THE SOLAR MODULE CONNECTORS MEET THE ISOLATING DEVICE REQUIREMENTS OUTLINED IN CEC 690.15 AND 690.33. *CODE COMPLIANT WIRE/CONDUIT SUBSITUTIONS MAY BE MADE TO THE ABOVE TABLE. *SEE THE NEXT PAGE FOR ELECTRICAL CALCULATIONS AND ADDITIONAL ELECTRICAL NOTES. ID UNGROUNDED CONDUCTORS NEUTRAL CONDUCTOR EQUIPMENT GND CONDUCTOR CONDUIT 1 (2) 10 AWG, PV WIRE, CU N/A (1) 6 AWG, SOLID BARE, CU FREE AIR 2 (4) 10 AWG, THWN-2, CU N/A (1) 10 AWG, THWN-2, CU 0.75" EMT 3 (2) 8 AWG, THWN-2, CU (1) 8 AWG, THWN-2, CU (1) 10 AWG, THWN-2, CU 0.75" EMT 4 (2) 8 AWG, THWN-2, CU (1) 8 AWG, THWN-2, CU (1) 10 AWG, THWN-2, CU 0.75" EMT DIAMOND ADU 1621 S DIAMOND ST, UNIT 2 SANTA ANA, CA 92704 PV-4A DATE: 01/13/2026 REV E AHJ: APN: 40824215 SANTA ANA CITYSCALE: SHEET SIZE: 11" x 17" TEMPLATE V2.0 PREPARED BY: HIGH LINE DESIGNS SCOTT TOYAMA STARS CONSTRUCTION SERVICES INC 6022 WESTERN AVE BUENA PARK, CA 90621 714.262.3929 HUY THIEU NGUYEN C10 #833971 ELECTRICAL CALCULATIONS NTS INVERTER OUTPUT CALCULATIONS & 705.12 COMPLIANCE ELECTRICAL NOTES (APPLICABILITY BASED ON SCOPE OF WORK) ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH NEC ARTICLE 250. A SUPPLEMENTAL GROUND ROD WILL BE DRIVEN IN ACCORDANCE WITH CEC 250.53(A)(3) IF THE EXISTING GROUND ROD HAS A RESISTANCE TO EARTH THAT IS GREATER THAN 25 OHMS. IF ANY EXISTING LOAD CONDUCTORS ARE EXTENDED BY MORE THAN 6', AFCI PROTECTION WILL BE PROVIDED PER CEC 210.12(D). PER CEC 690.47(A) PV SYSTEMS THAT ARE NOT SOLIDLY GROUNDED, THE EQUIPMENT GROUNDING CONDUCTOR FOR THE OUTPUT OF THE PV SYSTEMS SHALL BE PERMITTED TO BE THE CONNECTION TO GROUND FOR GROUND-FAULT PROTECTION AND EQUIPMENT GROUNDING OF THE PV ARRAY. THE ESS CIRCUIT BREAKER SHALL BE SECURED IN PLACE BY AN ADDITIONAL FASTENER PER CEC 408.36(D). NO SINGLE BACK-UP LOAD WILL BE LARGER THAN THE MAXIMUM CONTINUOUS OUTPUT OF THE ESS PER CEC 710.15(A). AS-BUILT CHANGES TO THE ABOVE WIRING ARE PERMISSIBLE AS LONG AS SUBSITUTIONS ARE CODE COMPLIANT. FOR EXAMPLE, APPROPRIATELY SIZED NM-B MAY BE USED FOR MICROINVERTER OUTPUT CIRCUITS IF INSTALLED IN ACCORDANCE WITH CEC ARTICLE 334, OR MC CABLE MAY BE USED FOR DC SOLAR STRINGS IF INSTALLED IN ACCORDANCE WITH CEC ARTICLE 330. ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT & HOLD A MINIMUM NEMA 3R RATING, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. CONDUCTORS EXPOSED TO WET CONDITIONS SHALL BE SUITABLE FOR USE IN WET CONDITIONS PER CEC 310.10(C). ALL TERMINAL TEMPERATURES OF EQUIPMENT WILL BE VERIFIED TO BE RATED FOR 75°C, OR THE WIRE WILL NEED TO BE RESIZED USING THE 60°C TERMINAL TEMPERATURE RATINGS FOR 100A OR LESS. ALL NM-B SHALL BE INSTALLED AND PROTECTED PER CEC 334, AND ALL SER CABLE SHALL BE INSTALLED AND PROTECTED PER CEC 338. ALL ROOFTOP RACEWAYS AND CABLES EXPOSED TO DIRECT SUNLIGHT WILL BE INSTALLED >7/8" ABOVE THE ROOF. x ID STARTING LOCATION FINAL LOCATION UNGROUNDED CONDUCTORS NEUTRAL CONDUCTOR EQUIPMENT GND CONDUCTOR CONTROL WIRE TERM. TEMP. # OF CCC ASHARE 2% HIGH TEMP.CCC ADJUSTMENT AMBIENT TEMP CORR.90°C RATING DERATED AMP. TERM. TEMP. RATING OCPD CONDUIT CONDUIT FILL LENGTH LOAD VOLTAGE VOLTAGE DROP 1 STRING JUNCTION BOX (2) 10 AWG, PV WIRE, CU N/A (1) 6 AWG, SOLID BARE, CU -- 75°C 2 31°C 20.0A N/A FREE AIR N/A 8FT 10.4A 86.22V 0.25% 2 JUNCTION BOX INVERTER (4) 10 AWG, THWN-2, CU N/A (1) 10 AWG, THWN-2, CU -- 75°C 4 31°C 35.0A N/A 0.75" EMT 19.09% 18FT 10.4A 86.22V 0.56% 3 INVERTER NON-FUSED AC DISCONNECT (2) 8 AWG, THWN-2, CU (1) 8 AWG, THWN-2, CU (1) 10 AWG, THWN-2, CU -- 75°C 2 31°C 50.0A 40A 0.75" EMT 23.86% 25FT 25.0A 240V 0.41% 4 NON-FUSED AC DISCONNECT ADU SUBPANEL (2) 8 AWG, THWN-2, CU (1) 8 AWG, THWN-2, CU (1) 10 AWG, THWN-2, CU -- 75°C 2 31°C 50.0A 40A 0.75" EMT 23.86% 5FT 25.0A 240V 0.08% x = x x = x 0.96 40.0Ax =1 N/AN/A N/A N/A 1 55.0A INVERTER OUTPUT CIRCUIT INVERTER OR ESS # OF INVERTERS / ESS CONTINUOUS OUTPUT 125% SAFETY FACTOR TOTAL BACKFEED MINIMUM BREAKER SIZE #1 GROWATT 6KW 1 25.00A 125% 31.25A 40A PANEL 705.12 COMPLIANCE BUSBAR OCPD PROTECTING PANEL BUSBAR X 120% MAX GENERATION BACKFEED MSP 705.12(B)(3)(2)200A 200A 240A 40A ADU SUBPANEL 705.12(B)(3)(2)125A N/A N/A N/A HOUSE SUBPANEL 705.12(B)(3)(3)125A N/A N/A N/A 38.4A 52.8A x x =1 55.0A 0.96 0.96 52.8A DIAMOND ADU 1621 S DIAMOND ST, UNIT 2 SANTA ANA, CA 92704 PV-5 DATE: 01/13/2026 REV E AHJ: APN: 40824215 SANTA ANA CITYSCALE: SHEET SIZE: 11" x 17" TEMPLATE V2.0 PREPARED BY: HIGH LINE DESIGNS SCOTT TOYAMA STARS CONSTRUCTION SERVICES INC 6022 WESTERN AVE BUENA PARK, CA 90621 714.262.3929 HUY THIEU NGUYEN C10 #833971 LABELS & PLACARDS NTS -THE LABELS/PLACARD SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD. -ALL WARNING & HAZARD LABELS SHALL BE INSTALLED PER CEC 110.21(B). -IF THERE IS EXISTING PV OR ESS, LABELS FOR EXISTING PV SYSTEMS WILL BE TRANSFERRED OR REPLACED ON NEW EQUIPMENT. WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. LOCATED AT ANY PANEL THAT MEETS CEC 705.12(B)(3)(3) 9 WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LOCATED AT POINT OF INTERCONNECTION. CEC 705.12(B)(3)(2) 1 WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LOCATED AT PV DISCONNECT CEC 690.13(B) !3 5 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS LOCATED AT MAIN SERVICE DISCONNECT. CEC 690.56(C)(2) 4 RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LOCATED AT MAIN SERVICE PANEL. CEC 690.56(C) 2 PHOTOVOLTAIC AC DISCONNECT MAXIMUM AC OPERATING CURRENT: LOCATED AT PV DISCONNECT. CEC 690.56(B), 609.54, 705.20 240V 25.0A NOMINAL OPERATING AC VOLTAGE: INSTALLED PER CEC 705.10 6 TWO POWER SOURCES SOURCES: UTILITY GRID & SOLAR WARNING!! 8 WARNING: PHOTOVOLTAIC POWER SOURCE LOCATED AT DC SOLAR CIRCUIT; CEC 690.31(D)(2) 7 PHOTOVOLTAIC SYSTEM DC DISCONNECT OPERATING VOLTAGE LOCATED AT PV DISCONNECT. CEC 690.56(B), 609.54, 705.20 OPERATING CURRENT MAX SYSTEM VOLTAGE SHORT CIRCUIT CURRENT 13.7A 143.7V 10.4A 184.5V CAUTION MULTIPLE SOURCES OF POWER WITH DISCONNECTS LOCATED AS SHOWN: LOCATED AT MAIN SERVICE PANEL. CEC 690.56(B), 690.4(D), 705.10 1621 S DIAMOND ST PV MODULES MAIN SERVICE DISCONNECT (RAPID SHUTDOWN INITIATION DEVICE) INVERTER FR O N T O F H O U S E PV DISCONNECT DIAMOND ADU 1621 S DIAMOND ST, UNIT 2 SANTA ANA, CA 92704 PV-6 DATE: 01/13/2026 REV E AHJ: APN: 40824215 SANTA ANA CITYSCALE: SHEET SIZE: 11" x 17" TEMPLATE V2.0 PREPARED BY: HIGH LINE DESIGNS SCOTT TOYAMA STARS CONSTRUCTION SERVICES INC 6022 WESTERN AVE BUENA PARK, CA 90621 714.262.3929 HUY THIEU NGUYEN C10 #833971 EQUIPMENT DATASHEET NTS DIAMOND ADU 1621 S DIAMOND ST, UNIT 2 SANTA ANA, CA 92704 PV-7 DATE: 01/13/2026 REV E AHJ: APN: 40824215 SANTA ANA CITYSCALE: SHEET SIZE: 11" x 17" TEMPLATE V2.0 PREPARED BY: HIGH LINE DESIGNS SCOTT TOYAMA STARS CONSTRUCTION SERVICES INC 6022 WESTERN AVE BUENA PARK, CA 90621 714.262.3929 HUY THIEU NGUYEN C10 #833971 EQUIPMENT DATASHEET NTS DIAMOND ADU 1621 S DIAMOND ST, UNIT 2 SANTA ANA, CA 92704 PV-8 DATE: 01/13/2026 REV E AHJ: APN: 40824215 SANTA ANA CITYSCALE: SHEET SIZE: 11" x 17" TEMPLATE V2.0 PREPARED BY: HIGH LINE DESIGNS SCOTT TOYAMA STARS CONSTRUCTION SERVICES INC 6022 WESTERN AVE BUENA PARK, CA 90621 714.262.3929 HUY THIEU NGUYEN C10 #833971 EQUIPMENT DATASHEET NTS DIAMOND ADU 1621 S DIAMOND ST, UNIT 2 SANTA ANA, CA 92704 1621 S DIAMOND ST UNIT 2 SANTA ANA, CA 92704 DIAMOND ADU PV-9 DATE: 11/10/2025 REV B AHJ: APN: 40824215 SANTA ANA CITYSCALE: SHEET SIZE: 11" x 17" TEMPLATE V2.0 PREPARED BY: HIGH LINE DESIGNS SCOTT TOYAMA HUY THIEU NGUYEN C10 #833971 EQUIPMENT DATASHEET NTSSTARS CONSTRUCTION SERVICES INC 6022 WESTERN AVE BUENA PARK, CA 90621 714.262.3929 1621 S DIAMOND ST UNIT 2 SANTA ANA, CA 92704 DIAMOND ADU PV-10 DATE: 11/10/2025 REV B AHJ: APN: 40824215 SANTA ANA CITYSCALE: SHEET SIZE: 11" x 17" TEMPLATE V2.0 PREPARED BY: HIGH LINE DESIGNS SCOTT TOYAMA HUY THIEU NGUYEN C10 #833971 EQUIPMENT DATASHEET NTSSTARS CONSTRUCTION SERVICES INC 6022 WESTERN AVE BUENA PARK, CA 90621 714.262.3929 PV-11 DATE: 01/13/2026 REV E AHJ: APN: 40824215 SANTA ANA CITYSCALE: SHEET SIZE: 11" x 17" TEMPLATE V2.0 PREPARED BY: HIGH LINE DESIGNS SCOTT TOYAMA STARS CONSTRUCTION SERVICES INC 6022 WESTERN AVE BUENA PARK, CA 90621 714.262.3929 HUY THIEU NGUYEN C10 #833971 EQUIPMENT DATASHEET NTS DIAMOND ADU 1621 S DIAMOND ST, UNIT 2 SANTA ANA, CA 92704 Exp.03/31/2026 For Structural Only