3606 S Van Ness Ave - REV 1 - Plan
PBA
>
Building
>
ProjectDox
>
V
>
Van Ness Ave
>
3606 S Van Ness Ave
>
3606 S Van Ness Ave - REV 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/18/2026 5:00:22 AM
Creation date
2/18/2026 5:00:08 AM
Metadata
Fields
Template:
Plan
Permit Number
20187288
20187922
101125560
Full Address
3606 S Van Ness Ave
Street Number
3606
Street Direction
S
Street Name
Van Ness
Street Suffix
Ave
Text box
ID:
1
Creator:
Import Agent
Created:
2/18/2026 5:00 AM
Modified:
2/17/2026 11:09 AM
Text:
Elec#: 20187922 REV TO: ELEC#: 20187288 APPROVALS: Elec: MSmith
ID:
2
Creator:
Import Agent
Created:
2/18/2026 5:00 AM
Modified:
2/17/2026 11:09 AM
Text:
**The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown.€**
Stamp
ID:
1
Creator:
Import Agent
Created:
2/18/2026 5:00 AM
Modified:
2/17/2026 11:09 AM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
COVER SHEET <br />REVDATEDESCRIPTION <br />VERSION <br />10/13/2025INITIAL RELEASE <br />SHEET NAME <br />SHEET NUMBER <br />PV-0 <br />PROJECT NAME <br />36 <br />0 <br />6 <br /> <br />S <br /> <br />V <br />A <br />N <br /> <br />N <br />E <br />S <br />S <br /> <br />A <br />V <br />E <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />, <br /> <br />U <br />S <br />A <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />YE <br /> <br />Z <br />H <br />U <br />ME <br />T <br />E <br />R <br /> <br />N <br />O <br /># <br />: <br /> <br />3 <br />2 <br />2 <br />0 <br />1 <br />0 <br />1 <br />1 <br />5 <br />6 <br />6 <br />1 <br />AGE <br />AP <br />N <br /># <br />: <br /> <br />4 <br />1 <br />0 <br />1 <br />4 <br />1 <br />3 <br />6 <br />AH <br />J <br />: <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />I <br />T <br />Y <br />APTUS ENERGY <br />PHOTOVOLTAIC ROOF MOUNT SYSTEM <br /> 3606 S VAN NESS AVE, SANTA ANA, CA 92707, USA <br />GENERAL: <br />1. UTILITY SHALL BE NOTIFIED BEFORE ACTIVATION OF <br />PHOTOVOLTAIC SYSTEM. <br />2. 110.2 APPROVAL: ALL ELECTRICAL EQUIPMENT SHALL <br />BE LABELED, LISTED, OR CERTIFIED BY A NATIONALLY <br />RECOGNIZED TESTING LABORATORY ACCREDITED BY <br />THE UNITED STATES OCCUPATIONAL SAFETY HEALTH <br />ADMINISTRATION <br />3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS <br />PRIOR TO INITIATING CONSTRUCTION. <br />4. CONTRACTOR SHALL REVIEW ALL MANUFACTURER <br />INSTALLATION DOCUMENTS PRIOR TO INITIATING <br />CONSTRUCTION. <br />5. ALL EQUIPMENT AND ASSOCIATED CONNECTIONS, <br />ETC, <br />AND ALL ASSOCIATED WIRING AND <br />INTERCONNECTIONS SHALL BE INSTALLED ONLY BY <br />QUALIFIED PERSONNEL. <br />6. THE CONTRACTOR OR OWNER MUST PROVIDE ROOF <br />ACCESS (LADDER TO ROOF) FOR ALL THE REQUIRED <br />INSPECTIONS. LADDERS MUST BE OSHA APPROVED, <br />MINIMUM TYPE I WITH A 250LB. RATING, IN GOOD <br />CONDITION AND DESIGNED FOR ITS INTENDED USE. <br />7. CONTRACTOR SHALL VERIFY THAT THE ROOF <br />STRUCTURE WILL WITHSTAND THE ADDITIONAL LOADS. <br />8. LAG SCREWS SHALL PENETRATE A MINIMUM 2" INTO <br />SOLID SAWN STRUCTURAL MEMBERS AND SHALL NOT <br />EXCEED MANUFACTURER RECOMMENDATIONS FOR <br />FASTENERS INTO ENGINEERED STRUCTURAL <br />MEMBERS. <br />9. AN ACCESS POINT SHALL BE PROVIDED THAT DOES <br />NOT PLACE THE GROUND LADDER OVER OPENINGS <br />SUCH AS WINDOWS OR DOORS ARE LOCATED AT <br />STRONG POINTS OF BUILDING CONSTRUCTION AND IN <br />LOCATIONS WHERE THE ACCESS POINT DOES NOT <br />CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS <br />TREE LIMBS, WIRES, OR SIGNS. <br />10. WHERE DC CONDUCTORS ARE RUN INSIDE <br />BUILDING, <br />THEY SHALL BE CONTAINED IN A METAL RACEWAY; <br />THEY SHALL NOT BE INSTALLED WITHIN 10" OF THE <br />ROOF DECKING OR SHEATHING EXCEPT WHERE <br />COVERED BY THE PV MODULES AND EQUIPMENT. <br />11. PLUMBING AND MECHANICAL VENTS THROUGH THE <br />ROOF <br />SHALL NOT BE COVERED BY SOLAR MODULES- - NO <br />BUILDING, PLUMBING OR MECHANICAL VENTS TO BE <br />COVERED, CONSTRUCTED OR ROUTED AROUND SOLAR <br />MODULES. <br />12. ALL FIELD -INSTALLED JUNCTION, PULL AND OUTLET <br />BOXES LOCATED BEHIND MODULES SHALL BE <br />ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A <br />MODULE SECURED BY REMOVABLE FASTENERS. <br /> 15 MODULES-ROOF MOUNTED - 6.450 kWDC, 10.000 kWAC <br />2 VICINITY MAP <br />SCALE: NTSPV-0 <br />1 AERIAL PHOTO <br />SCALE: NTSPV-0 <br />DESIGN CRITERIA: <br />PV-0 COVER SHEET <br />PV-1 SITE PLAN <br />PV-2 ATTACHMENT PLAN <br />PV-3 FLOOR PLAN <br />PV-4 STANDOFF DETAILS <br />PV-5 SINGLE LINE DIAGRAM & CALCULATION <br />PV-6 THREE LINE DIAGRAM & CALCULATION <br />PV-7 STRING MAP <br />PV-8 PLACARDS & WARNING LABELS <br />PV-9 ELEVATION DETAILS <br />PV-10 BATTERY MOUTING PLAN <br />PV-11 MAIN PANEL PHOTO <br />PV-12 MODULES DATASHEET <br />PV-13 INVERTER DATASHEET <br />PV-14 BATTERY DATASHEET <br />PV-15 OPTIMIZERS DATASHEET <br />PV-16 ATTACHMENT DATASHEET <br />PV-17 RAIL DATASHEET <br />SHEET INDEX <br />CONSTRUCTION: SFR <br />ZONING: RESIDENTIAL <br />GROUND SNOW LOAD : 0 PSF <br />WIND SPEED : 95 MPH <br />WIND EXPOSURE: B <br />RISK CATEGORY: II <br />GOVERNING CODES: <br />2022 CALIFORNIA ELECTRIC CODE (CEC) <br />2022 CALIFORNIA BUILDING CODE (CBC) <br />2022 CALIFORNIA RESIDENTIAL CODE (CRC) <br />2022 CALIFORNIA PLUMBING CODE (CPC) <br />2022 CALIFORNIA FIRE CODE (CFC) <br />2022 CALIFORNIA MECHANICAL CODE (CMC) <br />OWNER: <br />NAME: YE ZHU <br />ADDRESS: 3606 S VAN NESS AVE, SANTA <br />ANA, CA 92707, USA <br />AUTHORITIES HAVING JURISDICTION: <br />BUILDING: SANTA ANA CITY <br />ZONING: SANTA ANA CITY <br />UTILITY : SOUTHERN CALIFORNIA EDISON (SCE) <br />SYSTEM SUMMARY: <br />(N)15 - SUNKET SKT430M10-108D5 (430W) SOLAR <br />MODULES <br />(N)01 - AMENSOLAR N3H-X10US HYBRID INVERTER <br />(N)15 - TIGO TS4-A-F OPTIMIZERS <br />(N) 1 - JUNCTION BOX <br />(N) 1 - 60A FUSED AC DISCONNECT <br />(N) 1 - PLPA-L1-10K2-U BATTERY <br />ELECTRICAL: <br />1. WIRING MATERIALS SHALL COMPLY WITH MAXIMUM <br />CONTINUOUS CURRENT OUTPUT AT 25°C AND <br />MAXIMUM VOLTAGE AT 600V; WIRE SHALL BE WET <br />RATED AT 90°C. <br />2. EXPOSED PHOTOVOLTAIC SYSTEM CONDUCTORS ON <br />THE ROOF WILL BE USE 2 OR PV-TYPE WIRE. <br />3. PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE <br />IDENTIFIED AND GROUPED. THE MEANS OF <br />IDENTIFICATION SHALL BE PERMITTED BY SEPARATE <br />COLOR-CODING, MARKING TAPE, TAGGING OR OTHER <br />APPROVED MEANS. <br />4. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL <br />BE RAIN-TIGHT AND APPROVED FOR USE IN WET <br />LOCATIONS. <br />5. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE <br />BONDED AND ELECTRICALLY CONTINUOUS. <br />6. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND <br />CONDUITS ARE NOT SPECIFIED, CONTRACTOR SHALL <br />SIZE THEM ACCORDING TO APPLICABLE CODES. <br />7. REMOVAL OF A UTILITY-INTERACTIVE INVERTER OR <br />OTHER EQUIPMENT SHALL NOT DISCONNECT THE <br />BUILDING CONNECTION BETWEEN THE GROUNDING <br />ELECTRODE CONDUCTOR AND THE PV SOURCE <br />AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. <br />8. FOR GROUNDED SYSTEMS, THE PHOTOVOLTAIC <br />SOURCE AND OUTPUT CIRCUITS SHALL BE PROVIDED <br />WITH A GROUND-FAULT PROTECTION DEVICE OR <br />SYSTEM THAT DETECTS A GROUND FAULT, INDICATES <br />THAT FAULT HAS OCCURED AND AUTOMATICALLY <br />DISCONNECTS ALL CONDUCTORS OR CAUSES THE <br />INVERTER TO AUTOMATICALLY CEASE SUPPLYING <br />POWER TO OUTPUT CIRCUITS. <br />9. FOR UNGROUNDED SYSTEMS, THE INVERTER IS EQUIPPED <br />WITH GROUND FAULT PROTECTION AND A GFI FUSE <br />PORT FOR GROUND FAULT INDICATION. <br />10. PV MODULE FRAMES SHALL BE BONDED TO RACKING RAIL <br />OR BARE COPPER GEC/GEC PER THE MODULE <br />MANUFACTURER'S LISTED INSTRUCTION SHEET. <br />11. PV MODULE RACKING RAIL SHALL BE BONDED TO BARE <br />COPPER GEC VIA WEEB LUG, ILSCO GBL-4DBT LAY-IN <br />LUG, OR EQUIVALENT LISTED LUG. <br />12. THE PHOTOVOLTAIC INVERTER WILL BE LISTED AS UL 1741 <br />COMPLIANT. <br />13. RACKING AND BONDING SYSTEM TO BE UL2703 RATED. <br />14. ANY REQUIRED GROUNDING ELECTRODE CONDUCTOR <br />WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS <br />AS BUS BARS WITHIN LISTED EQUIPMENT. <br />15. WHEN BACKFED BREAKER IS THE METHOD OF UTILITY <br />INTERCONNECTION, THE BREAKERS SHALL NOT READ <br />"LINE AND LOAD". <br />16. WHEN APPLYING THE 120% RULE, THE SOLAR BREAKER <br />TO BE POSITIONED AT THE OPPOSITE END OF THE BUS <br />BAR FROM THE MAIN BREAKER. <br />17. THE WORKING CLEARANCE AROUND THE EXISTING <br />ELECTRICAL EQUIPMENT AS WELL AS THE NEW <br />ELECTRICAL EQUIPMENT WILL BE MAINTAINED. <br />Signed-01/21/2026 <br />EXP. 09/30/2026