HomeMy WebLinkAbout3606 S Van Ness Ave - REV 1 - PlanCOVER SHEET REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-0 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 3 2 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 4 1 0 1 4 1 3 6 AH J : S A N T A A N A C I T Y APTUS ENERGY PHOTOVOLTAIC ROOF MOUNT SYSTEM 3606 S VAN NESS AVE, SANTA ANA, CA 92707, USA GENERAL: 1. UTILITY SHALL BE NOTIFIED BEFORE ACTIVATION OF PHOTOVOLTAIC SYSTEM. 2. 110.2 APPROVAL: ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED, OR CERTIFIED BY A NATIONALLY RECOGNIZED TESTING LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION 3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO INITIATING CONSTRUCTION. 4. CONTRACTOR SHALL REVIEW ALL MANUFACTURER INSTALLATION DOCUMENTS PRIOR TO INITIATING CONSTRUCTION. 5. ALL EQUIPMENT AND ASSOCIATED CONNECTIONS, ETC, AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED PERSONNEL. 6. THE CONTRACTOR OR OWNER MUST PROVIDE ROOF ACCESS (LADDER TO ROOF) FOR ALL THE REQUIRED INSPECTIONS. LADDERS MUST BE OSHA APPROVED, MINIMUM TYPE I WITH A 250LB. RATING, IN GOOD CONDITION AND DESIGNED FOR ITS INTENDED USE. 7. CONTRACTOR SHALL VERIFY THAT THE ROOF STRUCTURE WILL WITHSTAND THE ADDITIONAL LOADS. 8. LAG SCREWS SHALL PENETRATE A MINIMUM 2" INTO SOLID SAWN STRUCTURAL MEMBERS AND SHALL NOT EXCEED MANUFACTURER RECOMMENDATIONS FOR FASTENERS INTO ENGINEERED STRUCTURAL MEMBERS. 9. AN ACCESS POINT SHALL BE PROVIDED THAT DOES NOT PLACE THE GROUND LADDER OVER OPENINGS SUCH AS WINDOWS OR DOORS ARE LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION AND IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS. 10. WHERE DC CONDUCTORS ARE RUN INSIDE BUILDING, THEY SHALL BE CONTAINED IN A METAL RACEWAY; THEY SHALL NOT BE INSTALLED WITHIN 10" OF THE ROOF DECKING OR SHEATHING EXCEPT WHERE COVERED BY THE PV MODULES AND EQUIPMENT. 11. PLUMBING AND MECHANICAL VENTS THROUGH THE ROOF SHALL NOT BE COVERED BY SOLAR MODULES- - NO BUILDING, PLUMBING OR MECHANICAL VENTS TO BE COVERED, CONSTRUCTED OR ROUTED AROUND SOLAR MODULES. 12. ALL FIELD -INSTALLED JUNCTION, PULL AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A MODULE SECURED BY REMOVABLE FASTENERS. 15 MODULES-ROOF MOUNTED - 6.450 kWDC, 10.000 kWAC 2 VICINITY MAP SCALE: NTSPV-0 1 AERIAL PHOTO SCALE: NTSPV-0 DESIGN CRITERIA: PV-0 COVER SHEET PV-1 SITE PLAN PV-2 ATTACHMENT PLAN PV-3 FLOOR PLAN PV-4 STANDOFF DETAILS PV-5 SINGLE LINE DIAGRAM & CALCULATION PV-6 THREE LINE DIAGRAM & CALCULATION PV-7 STRING MAP PV-8 PLACARDS & WARNING LABELS PV-9 ELEVATION DETAILS PV-10 BATTERY MOUTING PLAN PV-11 MAIN PANEL PHOTO PV-12 MODULES DATASHEET PV-13 INVERTER DATASHEET PV-14 BATTERY DATASHEET PV-15 OPTIMIZERS DATASHEET PV-16 ATTACHMENT DATASHEET PV-17 RAIL DATASHEET SHEET INDEX CONSTRUCTION: SFR ZONING: RESIDENTIAL GROUND SNOW LOAD : 0 PSF WIND SPEED : 95 MPH WIND EXPOSURE: B RISK CATEGORY: II GOVERNING CODES: 2022 CALIFORNIA ELECTRIC CODE (CEC) 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA FIRE CODE (CFC) 2022 CALIFORNIA MECHANICAL CODE (CMC) OWNER: NAME: YE ZHU ADDRESS: 3606 S VAN NESS AVE, SANTA ANA, CA 92707, USA AUTHORITIES HAVING JURISDICTION: BUILDING: SANTA ANA CITY ZONING: SANTA ANA CITY UTILITY : SOUTHERN CALIFORNIA EDISON (SCE) SYSTEM SUMMARY: (N)15 - SUNKET SKT430M10-108D5 (430W) SOLAR MODULES (N)01 - AMENSOLAR N3H-X10US HYBRID INVERTER (N)15 - TIGO TS4-A-F OPTIMIZERS (N) 1 - JUNCTION BOX (N) 1 - 60A FUSED AC DISCONNECT (N) 1 - PLPA-L1-10K2-U BATTERY ELECTRICAL: 1. WIRING MATERIALS SHALL COMPLY WITH MAXIMUM CONTINUOUS CURRENT OUTPUT AT 25°C AND MAXIMUM VOLTAGE AT 600V; WIRE SHALL BE WET RATED AT 90°C. 2. EXPOSED PHOTOVOLTAIC SYSTEM CONDUCTORS ON THE ROOF WILL BE USE 2 OR PV-TYPE WIRE. 3. PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR-CODING, MARKING TAPE, TAGGING OR OTHER APPROVED MEANS. 4. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN-TIGHT AND APPROVED FOR USE IN WET LOCATIONS. 5. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS. 6. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, CONTRACTOR SHALL SIZE THEM ACCORDING TO APPLICABLE CODES. 7. REMOVAL OF A UTILITY-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BUILDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PV SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. 8. FOR GROUNDED SYSTEMS, THE PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS SHALL BE PROVIDED WITH A GROUND-FAULT PROTECTION DEVICE OR SYSTEM THAT DETECTS A GROUND FAULT, INDICATES THAT FAULT HAS OCCURED AND AUTOMATICALLY DISCONNECTS ALL CONDUCTORS OR CAUSES THE INVERTER TO AUTOMATICALLY CEASE SUPPLYING POWER TO OUTPUT CIRCUITS. 9. FOR UNGROUNDED SYSTEMS, THE INVERTER IS EQUIPPED WITH GROUND FAULT PROTECTION AND A GFI FUSE PORT FOR GROUND FAULT INDICATION. 10. PV MODULE FRAMES SHALL BE BONDED TO RACKING RAIL OR BARE COPPER GEC/GEC PER THE MODULE MANUFACTURER'S LISTED INSTRUCTION SHEET. 11. PV MODULE RACKING RAIL SHALL BE BONDED TO BARE COPPER GEC VIA WEEB LUG, ILSCO GBL-4DBT LAY-IN LUG, OR EQUIVALENT LISTED LUG. 12. THE PHOTOVOLTAIC INVERTER WILL BE LISTED AS UL 1741 COMPLIANT. 13. RACKING AND BONDING SYSTEM TO BE UL2703 RATED. 14. ANY REQUIRED GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AS BUS BARS WITHIN LISTED EQUIPMENT. 15. WHEN BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, THE BREAKERS SHALL NOT READ "LINE AND LOAD". 16. WHEN APPLYING THE 120% RULE, THE SOLAR BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUS BAR FROM THE MAIN BREAKER. 17. THE WORKING CLEARANCE AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED. Signed-01/21/2026 EXP. 09/30/2026 18" FIRE SETBACK 36 " F I R E S E T B A C K 18" FIRE SETBACK 18'-7" 2' - 8 " 13'-4"1' - 3 " 79'-6" 51 ' - 1 0 " 79'-6" 51 ' - 1 0 " MS P IN V BA T T UM AC D MS P IN V BA T T UM AC D REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-1 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 3 2 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 4 1 0 1 4 1 3 6 AH J : S A N T A A N A C I T Y APTUS ENERGY SITE PLAN 67.79" 44 . 6 4 " PHOTOVOLTAIC MODULES SUNKET SKT430M10-108D5 (430W) 10.000 kW AC 6.450 kW DC ARRAY (15)SUNKET SKT430M10-108D5 (430W) SOLAR MODULES ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. ROOF MOUNTED PHOTOVOLTAIC ARRAY 15 SUNKET SKT430M10-108D5 (430W) SOLAR MODULES=6450 DC WATTS NOTE: AC CONDUIT RAN THROUGH THE ATTIC IN INTERIOR OF HOME 3/4" EMT S V A N N E S S A V E DR I V E W A Y (N)AMENSOLAR N3H-X10US HYBRID INVERTER ARRAY AREA & ROOF AREA CALC'S AREA OF NEW ARRAY (Sq. Ft.) AREA OF ROOF(PLAN VIEW) (Sq. Ft.) TOTAL ROOF AREA COVERED BY ARRAY % 315.22 2386 13.21% 13.21%ROOF AREA (ARRAY <33% OF ROOF AREA) (N)FUSED UTILITY AC DISCONNECT (N) PLPA-L1-10K2-U BATTERY NOTE: ROOMS AND AREAS WITHIN DWELLING UNITS, BASEMENTS AND ATTACHED GARAGES IN WHICH ESS ARE INSTALLED SHALL BE PROTECTED BY SMOKE ALARMS IN ACCORDANCE WITH SECTION R314. A HEAT DETECTOR, LISTED AND INTERCONNECTED TO THE SMOKE ALARMS, SHALL BE INSTALLED IN LOCATIONS WITHIN DWELLING UNITS AND ATTACHED GARAGES WHERE SMOKE ALARMS CANNOT BE INSTALLED BASED ON THEIR LISTING (E)MAIN SERVICE PANEL (E) UTILITY METER SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL # VMP IMP VOC ISC SUNKET SKT430M10-108D5 34.60 12.43 41.37 12.95 MODULE DIMENSION 67.79" L x 44.64" W (E) WINDOW LEGEND JUNCTION BOXJB FENCE PROPERTY LINE CONDUIT RUN AMENSOLAR N3H-X10US HYBRID INV ACD AC DISCONNECT PLPA-L1-10K2-U BATTERYBATT UM MSP MAIN SERVICE PANEL UTILITY METER Signed-01/21/2026 EXP. 09/30/2026 (N) AMENSOLAR N3H-X10US HYBRID INVERTER 41.7A, 240V DC+DC-L1L2NG L1L1 3 (N) VISIBLE LOCKABLE 2 POLE EATON DG222NRB 60A WITH 60A FUSES 'KNIFE' AC DISCONNECT BATT 2 M L1 (E) 100A/2P TO UTILITY GRID (E) BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V (E) MAIN SERVICE PANEL 100A RATED, 240V (E) MAIN BREAKER TO HOUSE 240 V, 100A/2P G LOAD 3 GEC EXISTING GROUNDING ELECTRODE SYSTE TO EARTH REF.NEC 250.52, 250.53(A) LINE SIDE TAP (N) PLPA-L1-10K2-U BATTERY 07 MODULES WITH OPTIMIZERS IN BRANCH CIRCUIT 2 08 MODULES WITH OPTIMIZERS IN BRANCH CIRCUIT 1 15 -SUNKET SKT430M10-108D5 430W SOLAR MODULES 15 - TIGO TS4-A-F OPTIMIZERS (N) JUNCTION BOX-1 ROOFTOP 600 V, NEMA 3-R UL LISTED DC+ DC+ 1PV WIRE (1) #6 BARE COPPER GROUND REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-5 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 3 2 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 4 1 0 1 4 1 3 6 AH J : S A N T A A N A C I T Y APTUS ENERGY SINGLE LINE DIAGRAM & CALCULATION SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL # VMP IMP VOC ISC SUNKET SKT430M10-108D5 34.60 12.43 41.37 12.95 MODULE DIMENSION 67.79" L x 44.64" W INVERTER SPECIFICATIONS MANUFACTURER / MODEL #QUANTITY NOMINAL AC POWER NOMINAL OUTPUT VOLTAGE NOMINAL OUTPUT CURRENT AMENSOLAR N3H-X10US HYBRID 01 10000 240 VAC 41.7 A AMBIENT TEMPERTURE SPECIFICATIONS RECORD LOW TEMP AMBIENT TEMP (HIGH TEMP 2%)CONDUIT HEIGHT CONDUCTOR TEMPERATURE RATE ON/OFF ROOF -2°31°7/8"90° (N) DC SYSTEM SIZE:- 15 x 430W = 6.450 kWDC (N) AC SYSTEM SIZE:- 01 x 10000W = 10.000 kWAC OPTIMIZER SPECIFICATIONS MANUFACTURER / MODEL # MAXIMUM SYSTEM VOLTAGE INPUT VOLTAGE RANGE INPUT CURRENT TIGO TS4-A-F OPTIMIZERS 1000 V/1500 V 12-80V 16 QUANTITY 15 (15) SUNKET SKT430M10-108D5 (430W) SOLAR MODULES (01)AMENSOLAR N3H-X10US HYBRID INVERTERS (15)TIGO TS4-A-F OPTIMIZERS (01) BRANCHED CIRCUIT OF 08 MODULES (01) BRANCHED CIRCUIT OF 07 MODULES CONDUCTOR SCHEDULE AND CALCULATIONS TAG LOCATION DESCRIPTION CURRENT (A) #C. CARRYING CONDUCTOR WIRE SIZE WIRE TYPE COND. RATING (A) AMBIENT TEMP COND. FILL FACTOR DERATED GROUND SIZE CONDUIT TYPE CONDUIT SIZEWIRE RUN FROM MAX. CURRENT PER STRING INVERTER OUTPUT CURRENT (A) 1 BEFORE INVERTER 16 -4 10 AWG THWN-2 35 1 0.8 28.00 10 AWG EMT 3/4" 2 BATTERY TO INVERTER -120 2 1 AWG THWN-2 150 1 1 150.00 6 AWG EMT 1-1/4" 3 INVERTER TO MAIN SERVICE PANEL -41.7 3 6 AWG THWN-2 65 1 1 65.00 10 AWG EMT 3/4" BATTERY SPECIFICATION MODEL PLPA-L1-10K2-U RATED ENERGY 10.24 KWH RATED VOLTAGE 51.2 V RATED CHARGE / DISCHARGE PEAK DISCHARGE CURRENT 160 A CURRENT 120 A (N) AMENSOLAR N3H-X10US HYBRID INVERTER 41.7A, 240V DC+DC-L1L2NG L1 L2 N G L1 L2 N G 3 (N) VISIBLE LOCKABLE 2 POLE EATON DG222NRB 60A WITH 60A FUSES 'KNIFE' AC DISCONNECT BATT 2 N M L2 L1 N (E) 100A/2P TO UTILITY GRID (E) BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V (E) MAIN SERVICE PANEL 100A RATED, 240V (E) MAIN BREAKER TO HOUSE 240 V, 100A/2P G LOAD 3 GEC EXISTING GROUNDING ELECTRODE SYSTE TO EARTH REF.NEC 250.52, 250.53(A) LINE SIDE TAP (N) PLPA-L1-10K2-U BATTERY 07 MODULES WITH OPTIMIZERS IN BRANCH CIRCUIT 2 G 08 MODULES WITH OPTIMIZERS IN BRANCH CIRCUIT 1 15 -SUNKET SKT430M10-108D5 430W SOLAR MODULES 15 - TIGO TS4-A-F OPTIMIZERS (N) JUNCTION BOX-1 ROOFTOP 600 V, NEMA 3-R UL LISTED DC+ DC- DC+ DC- 1PV WIRE (1) #6 BARE COPPER GROUND REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-6 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 32 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 41 0 1 4 1 3 6 AH J : SA N T A A N A C I T Y APTUS ENERGY THREE LINE DIAGRAM & CALCULATION SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL #VMP IMP VOC ISC SUNKET SKT430M10-108D5 34.60 12.43 41.37 12.95 MODULE DIMENSION 67.79" L x 44.64" W INVERTER SPECIFICATIONS MANUFACTURER / MODEL #QUANTITY NOMINAL AC POWER NOMINAL OUTPUT VOLTAGE NOMINAL OUTPUT CURRENT AMENSOLAR N3H-X10US HYBRID 01 10000 240 VAC 41.7 A AMBIENT TEMPERTURE SPECIFICATIONS RECORD LOW TEMP AMBIENT TEMP (HIGH TEMP 2%)CONDUIT HEIGHT CONDUCTOR TEMPERATURE RATE ON/OFF ROOF -2°31°7/8"90° (N) DC SYSTEM SIZE:- 15 x 430W = 6.450 kWDC (N) AC SYSTEM SIZE:- 01 x 10000W = 10.000 kWAC OPTIMIZER SPECIFICATIONS MANUFACTURER / MODEL # MAXIMUM SYSTEM VOLTAGE INPUT VOLTAGE RANGE INPUT CURRENT TIGO TS4-A-F OPTIMIZERS 1000 V/1500 V 12-80V 16 QUANTITY 15 (15) SUNKET SKT430M10-108D5 (430W) SOLAR MODULES (01) AMENSOLAR N3H-X10US HYBRID INVERTERS (15) TIGO TS4-A-F OPTIMIZERS (01) BRANCHED CIRCUIT OF 08 MODULES (01) BRANCHED CIRCUIT OF 07 MODULES BATTERY SPECIFICATION MODEL PLPA-L1-10K2-U RATED ENERGY 10.24 KWH RATED VOLTAGE 51.2 V RATED CHARGE / DISCHARGE PEAK DISCHARGE CURRENT 160 A CURRENT 120 A CONDUCTOR SCHEDULE AND CALCULATIONS TAG LOCATION DESCRIPTION CURRENT (A) #C. CARRYING CONDUCTOR WIRE SIZE WIRE TYPE COND. RATING (A) AMBIENT TEMP COND. FILL FACTOR DERATED GROUND SIZE CONDUIT TYPE CONDUIT SIZEWIRE RUN FROM MAX. CURRENT PER STRING INVERTER OUTPUT CURRENT (A) 1 BEFORE INVERTER 16 -4 10 AWG THWN-2 35 1 0.8 28.00 10 AWG EMT 3/4" 2 BATTERY TO INVERTER -120 2 1 AWG THWN-2 150 1 1 150.00 6 AWG EMT 1-1/4" 3 INVERTER TO MAIN SERVICE PANEL -41.7 3 6 AWG THWN-2 65 1 1 65.00 10 AWG EMT 3/4" REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-7 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 32 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 41 0 1 4 1 3 6 AH J : SA N T A A N A C I T Y APTUS ENERGY STRING MAP (15) TIGO TS4-A-F OPTIMIZERS SCALE:1/8" = 1'-0" VARIES STRING #2 STRING #1 (15) SUNKET SKT430M10-108D5 (430W) SOLAR MODULES (01) AMENSOLAR N3H-X10US HYBRID INVERTERS (15) TIGO TS4-A-F OPTIMIZERS (01) BRANCHED CIRCUIT OF 08 MODULES (01) BRANCHED CIRCUIT OF 07 MODULES REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-8 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 32 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 41 0 1 4 1 3 6 AH J : SA N T A A N A C I T Y APTUS ENERGY PLACARD & WARNING LABELS POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN MULTIPLE SOURCES OF POWER CAUTION ! (N) UTILITY AC DISCONNECT 3606 S VAN NESS AVE, SANTA ANA, CA 92707, USA N (E) UTILITY METER (N) AMENSOLAR N3H-X10US HYBRID INVERTER (N) PLPA-L1-10K2-U BATTERY MS P IN V BA T T UM (E) MAIN SERVICE PANEL WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM LABEL LOCATION: CONDUIT, COMBINER BOX (PER CODE: CEC690.31(D)(2) PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: POINT OF INTERCONNECTION PRODUCTION METER CEC 705.12(B)(3)(3) & CEC 690.59) NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE 2022 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. ELECTRICAL SHOCK HAZARD WARNING TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2022: CEC 706.15 (C)(4)& CEC 690.13(B) LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): CEC 2022: 690.56(C)(2) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE:SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): CEC 2022: IFC 690.56(C) ! 4" 3" WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT LABEL LOCATION: DC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC 690.13(B)) MAIN PHOTOVOLTAIC SYSTEM DISCONNECT LABEL LOCATION: MAIN SERVICE DISCONNECT / UTILITY METER (PER CODE: CEC 690.13(B)) 2022 CEC CODE 690.53 MAXIMUM DC VOLTAGE OF PV SYSTEM THIS EQUIPMENT FED BY MULTIPLE SOURCES: TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN POWER SUPPLY SHALL NOT EXCEED AMPACITY OF BUSBAR WARNING LABEL LOCATION: POINTS OF CONNECTION/BREAKER CODE: CEC 705.12(B)(3)(3) LABEL LOCATION: MSP (PER CODE: CEC 705.12(D) & CEC 690.59 CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED ! WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE ! LABEL LOCATION: SERVICE PANEL IF SUM OF BREAKERS EXCEEDS PANEL RATING CEC 705.12 (B)(3)(2) ! ! ! MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 41.70 AMPS 240 VAC LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2022: 690.54 PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT/BREAKER/ POINT OF CONNECTION (PER CODE: CEC 690.13(B) WARNING DISCONNECTION OF THE GROUNDED CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT LABEL LOCATION: INVERTER PER CODE: CEC 690.31(E) ! AC D ENERGY STORAGE SYSTEM NOMINAL VOLTAGE: 51.2 V NOMINAL CAPACITY: 200 AH (10.24 KWH) NOMINAL ENERGY: 10.24 KWH VOLTAGE RANGE: 44.8 V – 57.6 V MAX. CHARGE/DISCHARGE CURRENT: 120 A / 120 A BATTERY CHEMISTRY: LITHIUM IRON PHOSPHATE (LFP) MODEL: PLPA-L1-10K2-U DATE: ______________________ REQ'D BY NEC 706.7(D) APPLY TO: PLPA-L1-10K2-U REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-13 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 32 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 41 0 1 4 1 3 6 AH J : SA N T A A N A C I T Y APTUS ENERGY INVERTER DATASHEET REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-14 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 32 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 41 0 1 4 1 3 6 AH J : SA N T A A N A C I T Y APTUS ENERGY BATTERY DATASHEET ESS–INVERTER COMPATIBILITY NOTE: THE AMENSOLAR N3H-X10US HYBRID INVERTER IS TECHNICALLY COMPATIBLE WITH THE PLPA-L1-10K2-U LIFEPO₄ BATTERY. THE INVERTER SUPPORTS 48 V LITHIUM BATTERY SYSTEMS WITHIN A 40–60 V DC OPERATING RANGE AND COMMUNICATES VIA CAN/RS-485, WHICH ALIGNS WITH THE PLPA-L1-10K2-U BATTERY’S NOMINAL VOLTAGE RANGE AND INTEGRATED BMS COMMUNICATION PROTOCOLS. THE MAXIMUM CHARGE AND DISCHARGE CURRENT RATINGS OF BOTH DEVICES ARE WITHIN ALLOWABLE LIMITS. OVERALL SYSTEM INTEGRATION COMPLIES WITH MANUFACTURER-PUBLISHED ELECTRICAL, PROTECTION, AND COMMUNICATION SPECIFICATIONS. REVDATEDESCRIPTION VERSION 10/13/2025INITIAL RELEASE SHEET NAME SHEET NUMBER PV-15 PROJECT NAME 36 0 6 S V A N N E S S A V E , SA N T A A N A , C A 9 2 7 0 7 , U S A SHEET SIZE ANSI B 11" X 17" YE Z H U ME T E R N O # : 32 2 0 1 0 1 1 5 6 6 1 AGE AP N # : 41 0 1 4 1 3 6 AH J : SA N T A A N A C I T Y APTUS ENERGY OPTIMIZERS DATASHEET