APTUS ENERGY
PHOTOVOLTAIC ROOF MOUNT SYSTEM
3606 S VAN NESS AVE, SANTA ANA, CA 92707, USA
GENERAL:
1. UTILITY SHALL BE NOTIFIED BEFORE ACTIVATION OF
PHOTOVOLTAIC SYSTEM.
2. 110.2 APPROVAL: ALL ELECTRICAL EQUIPMENT SHALL
BE LABELED, LISTED, OR CERTIFIED BY A NATIONALLY
RECOGNIZED TESTING LABORATORY ACCREDITED BY
THE UNITED STATES OCCUPATIONAL SAFETY HEALTH
ADMINISTRATION
3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS
PRIOR TO INITIATING CONSTRUCTION.
4. CONTRACTOR SHALL REVIEW ALL MANUFACTURER
INSTALLATION DOCUMENTS PRIOR TO INITIATING
CONSTRUCTION.
5. ALL EQUIPMENT AND ASSOCIATED CONNECTIONS,
ETC,
AND ALL ASSOCIATED WIRING AND
INTERCONNECTIONS SHALL BE INSTALLED ONLY BY
QUALIFIED PERSONNEL.
6. THE CONTRACTOR OR OWNER MUST PROVIDE ROOF
ACCESS (LADDER TO ROOF) FOR ALL THE REQUIRED
INSPECTIONS. LADDERS MUST BE OSHA APPROVED,
MINIMUM TYPE I WITH A 250LB. RATING, IN GOOD
CONDITION AND DESIGNED FOR ITS INTENDED USE.
7. CONTRACTOR SHALL VERIFY THAT THE ROOF
STRUCTURE WILL WITHSTAND THE ADDITIONAL LOADS.
8. LAG SCREWS SHALL PENETRATE A MINIMUM 2" INTO
SOLID SAWN STRUCTURAL MEMBERS AND SHALL NOT
EXCEED MANUFACTURER RECOMMENDATIONS FOR
FASTENERS INTO ENGINEERED STRUCTURAL
MEMBERS.
9. AN ACCESS POINT SHALL BE PROVIDED THAT DOES
NOT PLACE THE GROUND LADDER OVER OPENINGS
SUCH AS WINDOWS OR DOORS ARE LOCATED AT
STRONG POINTS OF BUILDING CONSTRUCTION AND IN
LOCATIONS WHERE THE ACCESS POINT DOES NOT
CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS
TREE LIMBS, WIRES, OR SIGNS.
10. WHERE DC CONDUCTORS ARE RUN INSIDE
BUILDING,
THEY SHALL BE CONTAINED IN A METAL RACEWAY;
THEY SHALL NOT BE INSTALLED WITHIN 10" OF THE
ROOF DECKING OR SHEATHING EXCEPT WHERE
COVERED BY THE PV MODULES AND EQUIPMENT.
11. PLUMBING AND MECHANICAL VENTS THROUGH THE
ROOF
SHALL NOT BE COVERED BY SOLAR MODULES- - NO
BUILDING, PLUMBING OR MECHANICAL VENTS TO BE
COVERED, CONSTRUCTED OR ROUTED AROUND SOLAR
MODULES.
12. ALL FIELD -INSTALLED JUNCTION, PULL AND OUTLET
BOXES LOCATED BEHIND MODULES SHALL BE
ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A
MODULE SECURED BY REMOVABLE FASTENERS.
15 MODULES-ROOF MOUNTED - 6.450 kWDC, 10.000 kWAC
2 VICINITY MAP
SCALE: NTSPV-0
1 AERIAL PHOTO
SCALE: NTSPV-0
DESIGN CRITERIA:
PV-0 COVER SHEET
PV-1 SITE PLAN
PV-2 ATTACHMENT PLAN
PV-3 FLOOR PLAN
PV-4 STANDOFF DETAILS
PV-5 SINGLE LINE DIAGRAM & CALCULATION
PV-6 THREE LINE DIAGRAM & CALCULATION
PV-7 STRING MAP
PV-8 PLACARDS & WARNING LABELS
PV-9 ELEVATION DETAILS
PV-10 BATTERY MOUTING PLAN
PV-11 MAIN PANEL PHOTO
PV-12 MODULES DATASHEET
PV-13 INVERTER DATASHEET
PV-14 BATTERY DATASHEET
PV-15 OPTIMIZERS DATASHEET
PV-16 ATTACHMENT DATASHEET
PV-17 RAIL DATASHEET
SHEET INDEX
CONSTRUCTION: SFR
ZONING: RESIDENTIAL
GROUND SNOW LOAD : 0 PSF
WIND SPEED : 95 MPH
WIND EXPOSURE: B
RISK CATEGORY: II
GOVERNING CODES:
2022 CALIFORNIA ELECTRIC CODE (CEC)
2022 CALIFORNIA BUILDING CODE (CBC)
2022 CALIFORNIA RESIDENTIAL CODE (CRC)
2022 CALIFORNIA PLUMBING CODE (CPC)
2022 CALIFORNIA FIRE CODE (CFC)
2022 CALIFORNIA MECHANICAL CODE (CMC)
OWNER:
NAME: YE ZHU
ADDRESS: 3606 S VAN NESS AVE, SANTA
ANA, CA 92707, USA
AUTHORITIES HAVING JURISDICTION:
BUILDING: SANTA ANA CITY
ZONING: SANTA ANA CITY
UTILITY : SOUTHERN CALIFORNIA EDISON (SCE)
SYSTEM SUMMARY:
(N)15 - SUNKET SKT430M10-108D5 (430W) SOLAR
MODULES
(N)01 - AMENSOLAR N3H-X10US HYBRID INVERTER
(N)15 - TIGO TS4-A-F OPTIMIZERS
(N) 1 - JUNCTION BOX
(N) 1 - 60A FUSED AC DISCONNECT
(N) 1 - PLPA-L1-10K2-U BATTERY
ELECTRICAL:
1. WIRING MATERIALS SHALL COMPLY WITH MAXIMUM
CONTINUOUS CURRENT OUTPUT AT 25°C AND
MAXIMUM VOLTAGE AT 600V; WIRE SHALL BE WET
RATED AT 90°C.
2. EXPOSED PHOTOVOLTAIC SYSTEM CONDUCTORS ON
THE ROOF WILL BE USE 2 OR PV-TYPE WIRE.
3. PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE
IDENTIFIED AND GROUPED. THE MEANS OF
IDENTIFICATION SHALL BE PERMITTED BY SEPARATE
COLOR-CODING, MARKING TAPE, TAGGING OR OTHER
APPROVED MEANS.
4. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL
BE RAIN-TIGHT AND APPROVED FOR USE IN WET
LOCATIONS.
5. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE
BONDED AND ELECTRICALLY CONTINUOUS.
6. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND
CONDUITS ARE NOT SPECIFIED, CONTRACTOR SHALL
SIZE THEM ACCORDING TO APPLICABLE CODES.
7. REMOVAL OF A UTILITY-INTERACTIVE INVERTER OR
OTHER EQUIPMENT SHALL NOT DISCONNECT THE
BUILDING CONNECTION BETWEEN THE GROUNDING
ELECTRODE CONDUCTOR AND THE PV SOURCE
AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR.
8. FOR GROUNDED SYSTEMS, THE PHOTOVOLTAIC
SOURCE AND OUTPUT CIRCUITS SHALL BE PROVIDED
WITH A GROUND-FAULT PROTECTION DEVICE OR
SYSTEM THAT DETECTS A GROUND FAULT, INDICATES
THAT FAULT HAS OCCURED AND AUTOMATICALLY
DISCONNECTS ALL CONDUCTORS OR CAUSES THE
INVERTER TO AUTOMATICALLY CEASE SUPPLYING
POWER TO OUTPUT CIRCUITS.
9. FOR UNGROUNDED SYSTEMS, THE INVERTER IS EQUIPPED
WITH GROUND FAULT PROTECTION AND A GFI FUSE
PORT FOR GROUND FAULT INDICATION.
10. PV MODULE FRAMES SHALL BE BONDED TO RACKING RAIL
OR BARE COPPER GEC/GEC PER THE MODULE
MANUFACTURER'S LISTED INSTRUCTION SHEET.
11. PV MODULE RACKING RAIL SHALL BE BONDED TO BARE
COPPER GEC VIA WEEB LUG, ILSCO GBL-4DBT LAY-IN
LUG, OR EQUIVALENT LISTED LUG.
12. THE PHOTOVOLTAIC INVERTER WILL BE LISTED AS UL 1741
COMPLIANT.
13. RACKING AND BONDING SYSTEM TO BE UL2703 RATED.
14. ANY REQUIRED GROUNDING ELECTRODE CONDUCTOR
WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS
AS BUS BARS WITHIN LISTED EQUIPMENT.
15. WHEN BACKFED BREAKER IS THE METHOD OF UTILITY
INTERCONNECTION, THE BREAKERS SHALL NOT READ
"LINE AND LOAD".
16. WHEN APPLYING THE 120% RULE, THE SOLAR BREAKER
TO BE POSITIONED AT THE OPPOSITE END OF THE BUS
BAR FROM THE MAIN BREAKER.
17. THE WORKING CLEARANCE AROUND THE EXISTING
ELECTRICAL EQUIPMENT AS WELL AS THE NEW
ELECTRICAL EQUIPMENT WILL BE MAINTAINED.
Signed-01/21/2026
EXP. 09/30/2026
18" FIRE SETBACK
36
"
F
I
R
E
S
E
T
B
A
C
K
18" FIRE SETBACK
18'-7"
2'
-
8
"
13'-4"1'
-
3
"
79'-6"
51
'
-
1
0
"
79'-6"
51
'
-
1
0
"
MS
P
IN
V
BA
T
T
UM
AC
D
MS
P
IN
V
BA
T
T
UM
AC
D
REVDATEDESCRIPTION
VERSION
10/13/2025INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-1
PROJECT NAME
36
0
6
S
V
A
N
N
E
S
S
A
V
E
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
7
,
U
S
A
SHEET SIZE
ANSI B
11" X 17"
YE
Z
H
U
ME
T
E
R
N
O
#
:
3
2
2
0
1
0
1
1
5
6
6
1
AGE
AP
N
#
:
4
1
0
1
4
1
3
6
AH
J
:
S
A
N
T
A
A
N
A
C
I
T
Y
APTUS ENERGY
SITE PLAN
67.79"
44
.
6
4
"
PHOTOVOLTAIC MODULES
SUNKET SKT430M10-108D5 (430W)
10.000 kW AC
6.450 kW DC ARRAY
(15)SUNKET SKT430M10-108D5 (430W) SOLAR MODULES
ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE
PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR
DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN
LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD
OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS.
ROOF MOUNTED PHOTOVOLTAIC
ARRAY
15 SUNKET SKT430M10-108D5 (430W)
SOLAR MODULES=6450 DC WATTS
NOTE: AC CONDUIT RAN THROUGH THE
ATTIC IN INTERIOR OF HOME 3/4" EMT
S
V
A
N
N
E
S
S
A
V
E
DR
I
V
E
W
A
Y
(N)AMENSOLAR
N3H-X10US HYBRID
INVERTER
ARRAY AREA & ROOF AREA CALC'S
AREA OF NEW
ARRAY (Sq. Ft.)
AREA OF ROOF(PLAN
VIEW) (Sq. Ft.)
TOTAL ROOF AREA
COVERED BY ARRAY %
315.22 2386 13.21%
13.21%ROOF AREA (ARRAY <33% OF ROOF AREA)
(N)FUSED UTILITY
AC DISCONNECT
(N) PLPA-L1-10K2-U
BATTERY
NOTE: ROOMS AND AREAS WITHIN DWELLING UNITS,
BASEMENTS AND ATTACHED GARAGES IN WHICH ESS
ARE INSTALLED SHALL BE PROTECTED BY SMOKE
ALARMS IN ACCORDANCE WITH SECTION R314. A HEAT
DETECTOR, LISTED AND INTERCONNECTED TO THE
SMOKE ALARMS, SHALL BE INSTALLED IN LOCATIONS
WITHIN DWELLING UNITS AND ATTACHED GARAGES
WHERE SMOKE ALARMS CANNOT BE INSTALLED
BASED ON THEIR LISTING
(E)MAIN SERVICE
PANEL
(E) UTILITY METER
SOLAR MODULE SPECIFICATIONS
MANUFACTURER / MODEL # VMP IMP VOC ISC
SUNKET SKT430M10-108D5 34.60 12.43 41.37 12.95
MODULE DIMENSION 67.79" L x 44.64" W
(E) WINDOW
LEGEND
JUNCTION BOXJB
FENCE
PROPERTY LINE
CONDUIT RUN
AMENSOLAR N3H-X10US
HYBRID
INV
ACD AC DISCONNECT
PLPA-L1-10K2-U BATTERYBATT
UM
MSP MAIN SERVICE PANEL
UTILITY METER
Signed-01/21/2026
EXP. 09/30/2026
(N) AMENSOLAR N3H-X10US HYBRID INVERTER
41.7A, 240V
DC+DC-L1L2NG
L1L1
3
(N) VISIBLE LOCKABLE
2 POLE EATON
DG222NRB 60A WITH 60A
FUSES
'KNIFE' AC DISCONNECT
BATT
2
M
L1
(E) 100A/2P
TO UTILITY GRID
(E) BI-DIRECTIONAL UTILITY
METER 1-PHASE, 3-W,
120V/240V
(E) MAIN SERVICE PANEL
100A RATED, 240V
(E) MAIN BREAKER TO
HOUSE 240 V, 100A/2P
G
LOAD
3
GEC EXISTING GROUNDING
ELECTRODE SYSTE TO EARTH
REF.NEC 250.52,
250.53(A)
LINE SIDE TAP
(N) PLPA-L1-10K2-U BATTERY
07 MODULES WITH OPTIMIZERS IN BRANCH CIRCUIT 2
08 MODULES WITH OPTIMIZERS IN BRANCH CIRCUIT 1
15 -SUNKET SKT430M10-108D5 430W SOLAR MODULES
15 - TIGO TS4-A-F OPTIMIZERS
(N) JUNCTION
BOX-1
ROOFTOP
600 V, NEMA 3-R
UL LISTED
DC+
DC+
1PV WIRE
(1) #6 BARE
COPPER GROUND
REVDATEDESCRIPTION
VERSION
10/13/2025INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-5
PROJECT NAME
36
0
6
S
V
A
N
N
E
S
S
A
V
E
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
7
,
U
S
A
SHEET SIZE
ANSI B
11" X 17"
YE
Z
H
U
ME
T
E
R
N
O
#
:
3
2
2
0
1
0
1
1
5
6
6
1
AGE
AP
N
#
:
4
1
0
1
4
1
3
6
AH
J
:
S
A
N
T
A
A
N
A
C
I
T
Y
APTUS ENERGY
SINGLE LINE DIAGRAM
& CALCULATION
SOLAR MODULE SPECIFICATIONS
MANUFACTURER / MODEL # VMP IMP VOC ISC
SUNKET SKT430M10-108D5 34.60 12.43 41.37 12.95
MODULE DIMENSION 67.79" L x 44.64" W
INVERTER SPECIFICATIONS
MANUFACTURER / MODEL #QUANTITY
NOMINAL
AC
POWER
NOMINAL OUTPUT
VOLTAGE
NOMINAL OUTPUT
CURRENT
AMENSOLAR N3H-X10US
HYBRID 01 10000 240 VAC 41.7 A
AMBIENT TEMPERTURE SPECIFICATIONS
RECORD LOW TEMP AMBIENT TEMP (HIGH TEMP
2%)CONDUIT HEIGHT
CONDUCTOR
TEMPERATURE RATE
ON/OFF ROOF
-2°31°7/8"90°
(N) DC SYSTEM SIZE:- 15 x 430W = 6.450 kWDC
(N) AC SYSTEM SIZE:- 01 x 10000W = 10.000 kWAC
OPTIMIZER SPECIFICATIONS
MANUFACTURER / MODEL #
MAXIMUM
SYSTEM
VOLTAGE
INPUT
VOLTAGE
RANGE
INPUT
CURRENT
TIGO TS4-A-F OPTIMIZERS 1000 V/1500 V 12-80V 16
QUANTITY
15
(15) SUNKET SKT430M10-108D5 (430W) SOLAR MODULES
(01)AMENSOLAR N3H-X10US HYBRID INVERTERS
(15)TIGO TS4-A-F OPTIMIZERS
(01) BRANCHED CIRCUIT OF 08 MODULES
(01) BRANCHED CIRCUIT OF 07 MODULES
CONDUCTOR SCHEDULE AND CALCULATIONS
TAG LOCATION DESCRIPTION CURRENT (A)
#C. CARRYING
CONDUCTOR WIRE SIZE WIRE TYPE COND. RATING
(A)
AMBIENT
TEMP
COND. FILL
FACTOR
DERATED GROUND
SIZE CONDUIT TYPE CONDUIT
SIZEWIRE RUN FROM MAX. CURRENT
PER STRING
INVERTER OUTPUT
CURRENT (A)
1 BEFORE INVERTER 16 -4 10 AWG THWN-2 35 1 0.8 28.00 10 AWG EMT 3/4"
2 BATTERY TO INVERTER -120 2 1 AWG THWN-2 150 1 1 150.00 6 AWG EMT 1-1/4"
3 INVERTER TO MAIN SERVICE
PANEL -41.7 3 6 AWG THWN-2 65 1 1 65.00 10 AWG EMT 3/4"
BATTERY SPECIFICATION
MODEL PLPA-L1-10K2-U
RATED ENERGY 10.24 KWH
RATED VOLTAGE 51.2 V
RATED CHARGE / DISCHARGE
PEAK DISCHARGE CURRENT 160 A
CURRENT 120 A
(N) AMENSOLAR N3H-X10US HYBRID INVERTER
41.7A, 240V
DC+DC-L1L2NG
L1
L2
N
G
L1
L2
N
G
3
(N) VISIBLE LOCKABLE
2 POLE EATON
DG222NRB 60A WITH 60A
FUSES
'KNIFE' AC DISCONNECT
BATT
2
N
M L2
L1
N
(E) 100A/2P
TO UTILITY GRID
(E) BI-DIRECTIONAL UTILITY
METER 1-PHASE, 3-W,
120V/240V
(E) MAIN SERVICE PANEL
100A RATED, 240V
(E) MAIN BREAKER TO
HOUSE 240 V, 100A/2P
G
LOAD
3
GEC EXISTING GROUNDING
ELECTRODE SYSTE TO EARTH
REF.NEC 250.52,
250.53(A)
LINE SIDE TAP
(N) PLPA-L1-10K2-U BATTERY
07 MODULES WITH OPTIMIZERS IN BRANCH CIRCUIT 2
G
08 MODULES WITH OPTIMIZERS IN BRANCH CIRCUIT 1
15 -SUNKET SKT430M10-108D5 430W SOLAR MODULES
15 - TIGO TS4-A-F OPTIMIZERS
(N) JUNCTION
BOX-1
ROOFTOP
600 V, NEMA 3-R
UL LISTED
DC+
DC-
DC+
DC-
1PV WIRE
(1) #6 BARE
COPPER GROUND
REVDATEDESCRIPTION
VERSION
10/13/2025INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-6
PROJECT NAME
36
0
6
S
V
A
N
N
E
S
S
A
V
E
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
7
,
U
S
A
SHEET SIZE
ANSI B
11" X 17"
YE
Z
H
U
ME
T
E
R
N
O
#
:
32
2
0
1
0
1
1
5
6
6
1
AGE
AP
N
#
:
41
0
1
4
1
3
6
AH
J
:
SA
N
T
A
A
N
A
C
I
T
Y
APTUS ENERGY
THREE LINE DIAGRAM
& CALCULATION
SOLAR MODULE SPECIFICATIONS
MANUFACTURER / MODEL #VMP IMP VOC ISC
SUNKET SKT430M10-108D5 34.60 12.43 41.37 12.95
MODULE DIMENSION 67.79" L x 44.64" W
INVERTER SPECIFICATIONS
MANUFACTURER / MODEL #QUANTITY
NOMINAL
AC
POWER
NOMINAL OUTPUT
VOLTAGE
NOMINAL OUTPUT
CURRENT
AMENSOLAR N3H-X10US
HYBRID 01 10000 240 VAC 41.7 A
AMBIENT TEMPERTURE SPECIFICATIONS
RECORD LOW TEMP AMBIENT TEMP (HIGH TEMP
2%)CONDUIT HEIGHT
CONDUCTOR
TEMPERATURE RATE
ON/OFF ROOF
-2°31°7/8"90°
(N) DC SYSTEM SIZE:- 15 x 430W = 6.450 kWDC
(N) AC SYSTEM SIZE:- 01 x 10000W = 10.000 kWAC
OPTIMIZER SPECIFICATIONS
MANUFACTURER / MODEL #
MAXIMUM
SYSTEM
VOLTAGE
INPUT
VOLTAGE
RANGE
INPUT
CURRENT
TIGO TS4-A-F OPTIMIZERS 1000 V/1500 V 12-80V 16
QUANTITY
15
(15) SUNKET SKT430M10-108D5 (430W) SOLAR MODULES
(01) AMENSOLAR N3H-X10US HYBRID INVERTERS
(15) TIGO TS4-A-F OPTIMIZERS
(01) BRANCHED CIRCUIT OF 08 MODULES
(01) BRANCHED CIRCUIT OF 07 MODULES
BATTERY SPECIFICATION
MODEL PLPA-L1-10K2-U
RATED ENERGY 10.24 KWH
RATED VOLTAGE 51.2 V
RATED CHARGE / DISCHARGE
PEAK DISCHARGE CURRENT 160 A
CURRENT 120 A
CONDUCTOR SCHEDULE AND CALCULATIONS
TAG LOCATION DESCRIPTION CURRENT (A)
#C. CARRYING
CONDUCTOR WIRE SIZE WIRE TYPE COND. RATING
(A)
AMBIENT
TEMP
COND. FILL
FACTOR
DERATED GROUND
SIZE CONDUIT TYPE CONDUIT
SIZEWIRE RUN FROM MAX. CURRENT
PER STRING
INVERTER OUTPUT
CURRENT (A)
1 BEFORE INVERTER 16 -4 10 AWG THWN-2 35 1 0.8 28.00 10 AWG EMT 3/4"
2 BATTERY TO INVERTER -120 2 1 AWG THWN-2 150 1 1 150.00 6 AWG EMT 1-1/4"
3 INVERTER TO MAIN SERVICE
PANEL -41.7 3 6 AWG THWN-2 65 1 1 65.00 10 AWG EMT 3/4"
REVDATEDESCRIPTION
VERSION
10/13/2025INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-7
PROJECT NAME
36
0
6
S
V
A
N
N
E
S
S
A
V
E
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
7
,
U
S
A
SHEET SIZE
ANSI B
11" X 17"
YE
Z
H
U
ME
T
E
R
N
O
#
:
32
2
0
1
0
1
1
5
6
6
1
AGE
AP
N
#
:
41
0
1
4
1
3
6
AH
J
:
SA
N
T
A
A
N
A
C
I
T
Y
APTUS ENERGY
STRING MAP
(15) TIGO TS4-A-F OPTIMIZERS
SCALE:1/8" = 1'-0"
VARIES
STRING #2
STRING #1
(15) SUNKET SKT430M10-108D5 (430W) SOLAR MODULES
(01) AMENSOLAR N3H-X10US HYBRID INVERTERS
(15) TIGO TS4-A-F OPTIMIZERS
(01) BRANCHED CIRCUIT OF 08 MODULES
(01) BRANCHED CIRCUIT OF 07 MODULES
REVDATEDESCRIPTION
VERSION
10/13/2025INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-8
PROJECT NAME
36
0
6
S
V
A
N
N
E
S
S
A
V
E
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
7
,
U
S
A
SHEET SIZE
ANSI B
11" X 17"
YE
Z
H
U
ME
T
E
R
N
O
#
:
32
2
0
1
0
1
1
5
6
6
1
AGE
AP
N
#
:
41
0
1
4
1
3
6
AH
J
:
SA
N
T
A
A
N
A
C
I
T
Y
APTUS ENERGY
PLACARD & WARNING
LABELS
POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE
FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN
MULTIPLE SOURCES OF POWER
CAUTION !
(N) UTILITY
AC DISCONNECT
3606 S VAN NESS AVE, SANTA ANA, CA 92707, USA
N
(E) UTILITY METER
(N) AMENSOLAR
N3H-X10US HYBRID
INVERTER
(N) PLPA-L1-10K2-U
BATTERY
MS
P
IN
V
BA
T
T
UM
(E) MAIN SERVICE PANEL
WARNING DUAL POWER SOURCE
SECOND SOURCE IS PHOTOVOLTAIC SYSTEM
LABEL LOCATION:
CONDUIT, COMBINER BOX
(PER CODE: CEC690.31(D)(2)
PHOTOVOLTAIC POWER
SOURCE
LABEL LOCATION:
POINT OF INTERCONNECTION
PRODUCTION METER
CEC 705.12(B)(3)(3) & CEC 690.59)
NOTES AND SPECIFICATIONS:
·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE 2022 ARTICLE
110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR
IF REQUESTED BY THE LOCAL AHJ.
·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
WORDS, COLORS AND SYMBOLS.
·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING
METHOD AND SHALL NOT BE HAND WRITTEN.
·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
INVOLVED.
·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY
SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.
·DO NOT COVER EXISTING MANUFACTURER LABELS.
ELECTRICAL SHOCK HAZARD
WARNING
TERMINALS ON LINE AND LOAD
SIDES MAY BE ENERGIZED IN
THE OPEN POSITION
LABEL LOCATION:
INVERTER(S), AC DISCONNECT(S), AC
COMBINER PANEL (IF APPLICABLE).
PER CODE(S): CEC 2022: CEC 706.15
(C)(4)& CEC 690.13(B)
LABEL LOCATION:
UTILITY SERVICE ENTRANCE/METER, INVERTER/DC
DISCONNECT IF REQUIRED BY LOCAL AHJ, OR
OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ.
PER CODE(S): CEC 2022: 690.56(C)(2)
RAPID SHUTDOWN SWITCH
FOR SOLAR PV SYSTEM
MAXIMUM AC OPERATING CURRENT:
NOMINAL OPERATING AC VOLTAGE:SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
SOLAR ELECTRIC
PV PANELS
TURN RAPID SHUTDOWN
SWITCH TO THE "OFF"
POSITION TO SHUT DOWN
PV SYSTEM AND REDUCE
SHOCK HAZARD IN THE
ARRAY.
LABEL LOCATION:
ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING
MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED.
PER CODE(S): CEC 2022: IFC 690.56(C)
!
4"
3"
WARNING
ELECTRIC SHOCK HAZARD
TERMINALS ON BOTH LINE AND
LOAD SIDES MAY BE ENERGIZED
IN THE OPEN POSITION
DC VOLTAGE IS ALWAYS PRESENT
WHEN SOLAR MODULES ARE
EXPOSED TO SUNLIGHT
LABEL LOCATION:
DC DISCONNECT, POINT OF INTERCONNECTION
(PER CODE: CEC 690.13(B))
MAIN PHOTOVOLTAIC
SYSTEM DISCONNECT
LABEL LOCATION:
MAIN SERVICE DISCONNECT / UTILITY METER
(PER CODE: CEC 690.13(B))
2022 CEC CODE 690.53
MAXIMUM DC VOLTAGE
OF PV SYSTEM
THIS EQUIPMENT FED BY
MULTIPLE SOURCES:
TOTAL RATING OF ALL OVERCURRENT
DEVICES EXCLUDING MAIN POWER
SUPPLY SHALL NOT EXCEED
AMPACITY OF BUSBAR
WARNING
LABEL LOCATION:
POINTS OF CONNECTION/BREAKER
CODE: CEC 705.12(B)(3)(3)
LABEL LOCATION:
MSP (PER CODE: CEC 705.12(D) & CEC 690.59
CAUTION
PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED
!
WARNING
POWER SOURCE OUTPUT
CONNECTION
DO NOT RELOCATE THIS
OVERCURRENT DEVICE
!
LABEL LOCATION:
SERVICE PANEL IF SUM OF
BREAKERS EXCEEDS PANEL RATING
CEC 705.12 (B)(3)(2)
!
!
!
MAXIMUM AC OPERATING CURRENT:
NOMINAL OPERATING AC VOLTAGE:
41.70 AMPS
240 VAC
LABEL LOCATION:
AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION.
PER CODE(S): CEC 2022: 690.54
PHOTOVOLTAIC AC DISCONNECT
LABEL LOCATION:
AC DISCONNECT/BREAKER/
POINT OF CONNECTION
(PER CODE: CEC 690.13(B)
WARNING
DISCONNECTION OF THE
GROUNDED CONDUCTOR(S)
MAY RESULT IN OVERVOLTAGE
ON THE EQUIPMENT
LABEL LOCATION:
INVERTER
PER CODE: CEC 690.31(E)
!
AC
D
ENERGY STORAGE SYSTEM
NOMINAL VOLTAGE: 51.2 V
NOMINAL CAPACITY: 200 AH (10.24 KWH)
NOMINAL ENERGY: 10.24 KWH
VOLTAGE RANGE: 44.8 V – 57.6 V
MAX. CHARGE/DISCHARGE CURRENT: 120 A / 120 A
BATTERY CHEMISTRY: LITHIUM IRON PHOSPHATE (LFP)
MODEL: PLPA-L1-10K2-U
DATE: ______________________
REQ'D BY NEC 706.7(D)
APPLY TO:
PLPA-L1-10K2-U
REVDATEDESCRIPTION
VERSION
10/13/2025INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-13
PROJECT NAME
36
0
6
S
V
A
N
N
E
S
S
A
V
E
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
7
,
U
S
A
SHEET SIZE
ANSI B
11" X 17"
YE
Z
H
U
ME
T
E
R
N
O
#
:
32
2
0
1
0
1
1
5
6
6
1
AGE
AP
N
#
:
41
0
1
4
1
3
6
AH
J
:
SA
N
T
A
A
N
A
C
I
T
Y
APTUS ENERGY
INVERTER
DATASHEET
REVDATEDESCRIPTION
VERSION
10/13/2025INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-14
PROJECT NAME
36
0
6
S
V
A
N
N
E
S
S
A
V
E
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
7
,
U
S
A
SHEET SIZE
ANSI B
11" X 17"
YE
Z
H
U
ME
T
E
R
N
O
#
:
32
2
0
1
0
1
1
5
6
6
1
AGE
AP
N
#
:
41
0
1
4
1
3
6
AH
J
:
SA
N
T
A
A
N
A
C
I
T
Y
APTUS ENERGY
BATTERY
DATASHEET
ESS–INVERTER COMPATIBILITY NOTE: THE AMENSOLAR N3H-X10US HYBRID INVERTER IS TECHNICALLY COMPATIBLE WITH THE
PLPA-L1-10K2-U LIFEPO₄ BATTERY. THE INVERTER SUPPORTS 48 V LITHIUM BATTERY SYSTEMS WITHIN A 40–60 V DC OPERATING
RANGE AND COMMUNICATES VIA CAN/RS-485, WHICH ALIGNS WITH THE PLPA-L1-10K2-U BATTERY’S NOMINAL VOLTAGE RANGE
AND INTEGRATED BMS COMMUNICATION PROTOCOLS. THE MAXIMUM CHARGE AND DISCHARGE CURRENT RATINGS OF BOTH
DEVICES ARE WITHIN ALLOWABLE LIMITS. OVERALL SYSTEM INTEGRATION COMPLIES WITH MANUFACTURER-PUBLISHED
ELECTRICAL, PROTECTION, AND COMMUNICATION SPECIFICATIONS.
REVDATEDESCRIPTION
VERSION
10/13/2025INITIAL RELEASE
SHEET NAME
SHEET NUMBER
PV-15
PROJECT NAME
36
0
6
S
V
A
N
N
E
S
S
A
V
E
,
SA
N
T
A
A
N
A
,
C
A
9
2
7
0
7
,
U
S
A
SHEET SIZE
ANSI B
11" X 17"
YE
Z
H
U
ME
T
E
R
N
O
#
:
32
2
0
1
0
1
1
5
6
6
1
AGE
AP
N
#
:
41
0
1
4
1
3
6
AH
J
:
SA
N
T
A
A
N
A
C
I
T
Y
APTUS ENERGY
OPTIMIZERS
DATASHEET