Loading...
HomeMy WebLinkAbout3600 S Susan St - PlanRE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SETRACKING CONSTRUCTION SET GENERAL NOTES: 1.ALL SITE, PROJECT, AND BUILDING DETAILS ARE PROVIDED BY CUSTOMER OR GENERATED VIA SATELLITE IMAGERY FROM INFORMATION PROVIDED BY CUSTOMER. PANELCLAW IS NOT RESPONSIBLE FOR SITE INACCURACIES THAT COULD LEAD TO CHANGES TO THESE DRAWING DETAILS AND ARRAY LAYOUT CONFIGURATIONS. ALL INFORMATION CONTAINED WITHIN THESE DOCUMENTS ARE TO BE FIELD VERIFIED BY CUSTOMER AND INSTALLER. ANY CHANGES OR MODIFICATIONS TO THESE DOCUMENTS, CONTAINED INFORMATION, OR FINAL ARRAY AND MOUNTING SYSTEM INSTALLATIONS MUST BE SUBMITTED TO PANELCLAW AND OTHER PROJECT AUTHORITIES FOR APPROVAL. 2.REFER TO AND FOLLOW THE APPROPRIATE PANELCLAW INSTALLATION MANUALS AND PROCEDURES DURING THE INSTALLATION PROCESS. NOT FOLLOWING SUCH PROCEDURES AND METHODS COULD RESULT IN DAMAGE TO THE COMPONENTS OR MAY VOID THE PRODUCT WARRANTY. 3.ARRAY SETBACKS: ALL ARRAYS ARE REQUIRED TO BE SETBACK 4-FEET FROM ALL ROOF EDGES UNLESS OTHERWISE SPECIFIED AND CALLED OUT ON THE ARRAY DIAGRAMS ON THIS PAGE OR ON ADDITIONAL ARRAY BALLAST PAGES. 4.REFER TO THE SPECIFIC ARRAY BALLAST SHEETS FOR BALLASTING REQUIREMENTS BASED ON THE PROVIDED SITE INFORMATION. 5.SYSTEM PSF INCLUDES ALL PANELCLAW RACKING COMPONENTS, MECHANICAL ATTACHMENTS (IF APPLICABLE), PV MODULE AND BALLAST BLOCKS. FOR MAXIMUM SYSTEM POINT LOAD SUMMARY (PLS), REFER TO CALCULATIONS. 6.PANELCLAW AND/OR PANELCLAW CONSULTING ENGINEERS ARE NOT RESPONSIBLE FOR DETERMINING THE ADEQUACY OF THE STRUCTURE TO SUPPORT LOADS IMPOSED BY THE ARRAY AND MOUNTING SYSTEM. SUPPORT STRUCTURE TO BE CHECKED BY OTHERS. 7.ALWAYS ALLOW A MINIMUM OF 6" CLEARANCE BETWEEN NEIGHBORING SUBARRAYS, 6" BETWEEN SUBARRAYS AND ALL FIXED ROOF OBJECTS AND 4' BETWEEN SUBARRAYS AND ROOF EDGES. REFER TO LOCAL FIRE CODES AND ELECTRICAL CODES FOR ADDITIONAL REQUIREMENTS WHICH MAY GOVERN DESIGN. SUBARRAYS THAT USE A SEISMIC ANALYSIS METHOD OF DELTA MPV PREDICTED MOVEMENT HAVE THEIR OWN CLEARANCE REQUIREMENTS. REFER TO THE BALLAST LAYOUT SHEETS WITHIN THIS DOCUMENT FOR DETAILS. 8.BALLAST BLOCK DIMENSIONS MUST CONFORM TO THE FOLLOWING SPECIFICATIONS: 3-3/4” THICK MAX., 7-5/8” ± 1/8” WIDTH, 15-5/8” ± 1/8” LENGTH. 9.IF AN ARRAY CLEARANCES TABLE APPEARS BELOW ON THIS PAGE, THE DESIGN UTILIZES THIRD PARTY SEISMIC NON-LINEAR RESPONSE ANALYSIS TO ESTIMATE MAXIMUM ARRAY SEISMIC DISPLACEMENT. THE PREDICTED MOVEMENT IS ONLY AN ESTIMATE. PANELCLAW IS NOT RESPONSIBLE OR LIABLE FOR ANY DAMAGES OR COSTS ASSOCIATED WITH PV ARRAY MOVEMENT INCLUDING MOVEMENT IN EXCESS OF THE CLEARANCES NOTED IN THIS DOCUMENT OR ANY REQUIREMENT TO REPOSITION THE ARRAYS IF MOVEMENT OCCURS. 10.DEFLECTORS MUST BE INSTALLED WHEN WINDS ARE EXPECTED TO EXCEED APPROX. 25% OF WIND SPEED DOCUMENTED IN SITE DESIGN CRITERIA TABLE. DEFLECTORS ARE REQUIRED ON ALL MODULES UNLESS OTHERWISE NOTED ON BALLAST LAYOUT PAGES. SHEET INDEX NO.DESCRIPTION PC-1 COVER SHEET PC-2 PROJECT SUMMARY PC-3 ARRAY SITE MAP PC-4 TYPICAL ARRAY DIMENSIONS PC-5 ASSEMBLIES PC-6 RACKING COMPONENTS PC-7 BALLAST LEGEND PC-8 TO PC-9 BALLAST LAYOUT - 1 TO 2 PC-10 MECHANICAL ATTACHMENT DETAIL Site Design Criteria - Flat Roof PV System Basis of Design Roof Live Load (psf)20(see footnote 1) Ground Snow Pg (psf)0 Flat Roof Snow (psf)0 Snow Importance Factor (Is)1.0 Wind Design Data Basic Wind Speed (mph)95 Risk Category II Wind Exposure C Earthquake Design Data Risk Category II Importance Factor (Ie)1.00 Component Importance Factor (Ip)1.0 Mapped Acceleration Parameter (Ss)1.308 Mapped Acceleration Parameter (S1)0.470 Seismic Site Class D Design Spectral Acceleration Parameter (Sds)1.046 Design Spectral Acceleration Parameter (Sd1)0.573 Seismic Design Category (SDC)D Basic seismic-force-resisting system(s)roof anchors Base Design Shear = Fp x W 0.50 W Response Modification Factor (Rp)2.5 Analysis Procedure ASCE 7 sec. 13.3/4 Design Code (with local amendments)CBC 2022 -ASCE 7 - 16 ALTERNATE DESIGN METHOD 1. Roof Live Load only applicable to areas not covered by PV modules. Reference SEAOC Design Guidelines THIS CONSTRUCTION SET PROVIDES THE RACKING LAYOUT FOR ALL ARRAYS WITH NUMBER OF BALLAST BLOCKS AND/OR MECHANICAL ATTACHMENTS BASED ON THE APPROVED STRUCTURAL CALCULATIONS FOR THE COMPLETED INSTALLED CONDITION OF THE SOLAR ARRAY. THE INSTALLER IS RESPONSIBLE FOR THE SAFETY AND CARE OF THE ARRAY DURING ALL PHASES OF INSTALLATION. THEREFORE, THE INSTALLER MUST MONITOR THE WEATHER FORECAST AND TAKE NECESSARY PRECAUTIONS (SEE GENERAL NOTE #10) TO TEMPORARILY SHORE/BRACE ALL ARRAYS DURING CONSTRUCTION UNTIL INSTALLATION IS COMPLETED IN CONFORMANCE WITH THIS APPROVED CONSTRUCTION SET AND THE PRODUCT INSTALLATION MANUAL (SEE GENERAL NOTE #2). THE INSTALLER HAS SOLE RESPONSIBILITY FOR THE MEANS, METHODS, AND TECHNIQUES OF CONSTRUCTION OF THE SOLAR ARRAY FOR COMPLIANCE WITH LAWS, REGULATIONS, AND CODES, AND FOR THE SAFETY OF CONSTRUCTION APPLICABLE TO THIS WORK. APPROVED FOR CONSTRUCTION Calsolar inc South Coast Technology Center 3600 S Susan St, Santa Ana, CA 92704, USA COVER SHEET PC-10 25.02.04.0 v3.0.9406.0.5 CM 0 In i t i a l L a y o u t AW 20 2 5 - 0 5 - 0 2 25-0242-3336 5/7/2025 TROY E.TURLEY Bldg #101123829 Elect #20185952 APPROVALS: PLNG - C. Santana BLDG - J. Lo PUBLIC WORKS - Y. Soto ELECT - M. Smith U-ANCHOR 2600 MECHANICAL ATTACHMENT ø 6.4 mm (0.25 in) MECHANICAL ATTACHMENT WORST-CASE SERVICE LOAD (LB) HORIZONTAL (H)VERTICAL (V) WIND SEISMIC WIND MAXIMUM ALLOWABLE LOAD (LB) HORIZONTAL (H)VERTICAL (V) RACKING CONSTRUCTION SET Calsolar inc South Coast Technology Center 3600 S Susan St, Santa Ana, CA 92704, USA 0 PC-10 MECHANICAL ATTACHMENT DETAIL 25.02.04.0 v3.0.9406.0.5 CM 0 In i t i a l L a y o u t AW 20 2 5 - 0 5 - 0 2 0 242 523 650 525 APPROVED FOR CONSTRUCTION PC-10 PC-10 PC-10 25-0242-3336 5/7/2025 TROY E.TURLEY See "Sealed-PE Calc- 25035 South Coast Tech" For deck mount installation: For (4) UltraFast #12 screws embedded into 1/2-inch plywood (Appendix 4): - Allowable Uplift = 4 x 326 = 1304 lbs > 525 lbs OK RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: SITE MAP A PC-2NTS RACKING CONSTRUCTION SET Calsolar inc South Coast Technology Center 3600 S Susan St, Santa Ana, CA 92704, USA PROJECT SUMMARY PC-20 25.02.04.0 v3.0.9406.0.5 CM clawFRplus 10 Degree - 29 cm PROJECT PART QUANTITY ITEM PART NUMBER QTY Base 500050202 222 BASE, 02, CFR Module Connector 500063304 194 MODULE CONNECTOR, 1150, 10D, CFRP Rail 2000895 300 RAIL, 2500, CFR Cam 5000630 194 CAM, 10D, CFRP Cam Claw 2000854 194 CAM CLAW, CFRP Deflector 200088705 97 DEFLECTOR, 10D, 2300, CFR Bolt 2000697 1017 BLT, HEX FLG, TRI, M6X16, GR8.8, PATCH CONCRETE MASONRY UNIT N/A 370 BLOCK, CONCRETE, 32.6 LB, - Xin x 8in x 16in NOMINAL, PARTNER SUPPLIED, SEE INSTALLATION MANUAL APPROVED FOR CONSTRUCTION MECHANICAL ATTACHMENT PART QUANTITY MA Hardware Kit 5000423 4 HW KIT, MA STRUT, 2500, CFR MA Strut 2000930 37 MA STRUT, 2500, CFR Mechanical Attachment TBD 37 To Be Determined (U-Anchor 2600) TOTAL MECHANICAL ATTACHMENT COUNT 37 PROJECT SUMMARY MODULE TYPE PHONO SOLAR PS585M8GFH-24/TNH MODULE DIMENSIONS (IN.)89.69 X 44.65 X 1.38 NUMBER OF MODULES 97 MODULE WATTAGE (W STC)585 SYSTEM SIZE (kW STC)56.745 SYSTEM WEIGHT (LB)20781 SYSTEM AREA (SQ FT.)3345 AGGREGATE SYSTEM LOAD (PSF)6.21 NUMBER OF ARRAYS 2 ARRAY TILT (DEG)8.99 0 In i t i a l L a y o u t AW 20 2 5 - 0 5 - 0 2 Roof 1 25-0242-3336 5/7/2025 TROY E.TURLEY BASE HOLE "2" BASE HOLE "1" BASE HOLE "1" BASE HOLE "2" BASE HOLE "3" BASE HOLE "3" BASE HOLE "1"BASE HOLE "3"BASE HOLE "1"BASE HOLE "3"BASE HOLE "3"BASE HOLE "1"BASE HOLE "3"BASE HOLE "2" ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER ORIENTATION MARKER EXAMPLE ARRAY CONSTRUCTION F NTS RACKING CONSTRUCTION SET Calsolar inc South Coast Technology Center 3600 S Susan St, Santa Ana, CA 92704, USA ASSEMBLIES PC-50 25.02.04.0 v3.0.9406.0.5 CM APPROVED FOR CONSTRUCTION PC-5 PC-5 PC-5 PC-5 PC-5 PC-5 STANDARD ASSEMBLY QUANTITY NORTH ASSEMBLY 28 SOUTH ASSEMBLY 28 MIDDLE ASSEMBLY 138 NORTH SOUTH ASSEMBLY 0 NOTE: ASSEMBLIES IN THIS TABLE USE THE STANDARD 2-PAD BASE CAM SPACING mm 53UNITS inches 2 1/8 25-0242-3336 5/7/2025 TROY E.TURLEY MECHANICAL ATTACHMENT AT INDICATED LOCATION NOTE: EXAMPLE BALLAST AND ATTACHMENTS SHOWN ON THIS PAGE ARE FOR REFERENCE ONLY. REFER TO BALLAST MAP SHEETS FOR ARRAY SPECIFIC BALLAST/ATTACHMENT REQUIREMENTS. BALLAST QUANTITY: "#"=QUANTITY OF BALLAST BLOCK INSTALLEDCENTERED UNDER MODULE IF NO BALLAST QUANTITY SHOWN, DO NOT PLACE BALLAST SEE INSTALLATION MANUAL FOR NOTES ON INSTALLING MORE THAN FOUR BALLAST BLOCKS PER MODULE DO NOT INSTALL ADDITIONAL RAIL TO HOLDBALLAST ON MODULES WITH NO BALLASTSHOWN. MODULES LONGER THAN 2100 MM WITH 7 OR 8 BALLAST BLOCKS REQUIRE TWO (2) RAILS. ARRAY CROSS SECTION VIEW A NTS RACKING CONSTRUCTION SET Calsolar inc South Coast Technology Center 3600 S Susan St, Santa Ana, CA 92704, USA 0 PC-7 BALLAST LEGEND APPROVED FOR CONSTRUCTION 25.02.04.0 v3.0.9406.0.5 CM PC-7 PC-7 0 In i t i a l L a y o u t AW 20 2 5 - 0 5 - 0 2 25-0242-3336 5/7/2025 TROY E.TURLEY RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.1 ROOF INFORMATION ROOF HEIGHT (FT)48.00 PARAPET HEIGHT (FT) 4.0 ROOF TILT (DEG) 1 ROOF TYPE Asphalt SBS Adhered SPECIFICATIONS NUMBER OF MODULES 49 MODULE POWER (W) 585 ARRAY OUTPUT (Kw) 28.665 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 116 Module Connector 98 Rail 162 Cam 98 Cam Claw 98 Deflector 49 Ballast Block 223 Mechanical Attachment 17 LOADING DETAILS SINGLE MODULE WT (LB) 70.5 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 11686 ARRAY AREA (SQ. FT)1689 ARRAY LOAD (PSF) 6.92 APPROVED FOR CONSTRUCTION Calsolar inc South Coast Technology Center 3600 S Susan St, Santa Ana, CA 92704, USA BALLAST LAYOUT - 1.1 PC-80 25.02.04.0 v3.0.9406.0.5 CM BALLAST LAYOUT - 1.1 PC-8 0 In i t i a l L a y o u t AW 20 2 5 - 0 5 - 0 2 1/6" = 1'-0" 4 4 4 8 4 4 4 8 4 4 4 4 8 2 4 4 4 4 5 4 4 4 5 4 4 6 5 4 4 7 5 7 4 6 4 7 7 7 5 7 7 4 7 44 32.05' 67.74' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 18 SOUTH ASSEMBLY 18 MIDDLE ASSEMBLY 62 NORTH SOUTH ASSEMBLY 0 25-0242-3336 5/7/2025 TROY E.TURLEY RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: A RACKING CONSTRUCTION SET ARRAY 1.2 ROOF INFORMATION ROOF HEIGHT (FT)48.00 PARAPET HEIGHT (FT) 4.0 ROOF TILT (DEG) 1 ROOF TYPE Asphalt SBS Adhered SPECIFICATIONS NUMBER OF MODULES 48 MODULE POWER (W) 585 ARRAY OUTPUT (Kw) 28.08 ARRAY AZIMUTH 180 PART QUANTITIES ITEM QTY Base 106 Module Connector 96 Rail 138 Cam 96 Cam Claw 96 Deflector 48 Ballast Block 147 Mechanical Attachment 20 LOADING DETAILS SINGLE MODULE WT (LB) 70.5 SINGLE CMU WT (LB) 32.6 TOTAL ARRAY WT (LB) 9096 ARRAY AREA (SQ. FT)1656 ARRAY LOAD (PSF) 5.49 APPROVED FOR CONSTRUCTION Calsolar inc South Coast Technology Center 3600 S Susan St, Santa Ana, CA 92704, USA BALLAST LAYOUT - 1.2 PC-90 25.02.04.0 v3.0.9406.0.5 CM BALLAST LAYOUT - 1.2 PC-9 0 In i t i a l L a y o u t AW 20 2 5 - 0 5 - 0 2 1/6" = 1'-0" 2 5 3 3 3 3 2 3 4 6 1 1 5 3 7 1 8 1 7 2 82 82 83 8 1 4 8 8 3 5 2 7 64.16' 37.60' ASSEMBLY QUANTITIES ASSEMBLY QTY NORTH ASSEMBLY 10 SOUTH ASSEMBLY 10 MIDDLE ASSEMBLY 76 NORTH SOUTH ASSEMBLY 0 25-0242-3336 5/7/2025 TROY E.TURLEY 4/30/2025 KG PV-1 Date Plotted: Drawn By Checked By SHEET NO. SHEET NAME SIGNATURE & SEAL Project Number 200 S. San Pedro St #500 Los Angeles, CA 90012, USA info@calsolarinc.com www.calsolarinc.com C-46 SOLAR LIC. #1004246 800-784-7612 No.Description Date 36 0 0 , S S U S A N S T , SA N T A A N A , CA 92 7 0 4 SO U T H C O A S T T E C H N O L O G Y C E N T E R (56 . 7 4 5 K W D C S T C / 50 . 0 0 0 K W A C C E C ) SH 1 REVISION 04/16/2025 PROJECT LOCATION PROJECT INFORMATION PROJECT NAME: SOUTH COAST TECHNOLOGY CENTER - BUILDING #1 C&S & LL TI SITE ADDRESS: 3600 S SUSAN ST, SANTA ANA, CA 92704 AHJ: CITY OF SANTA ANA OWNER: C. J. SEGERSTROM & SONS 3315 FARVIEW RD. COSTA MESA, CA 92626 BUILDING HEIGHT: 48'-4" OCCUPANCY: B, S-1, F-1 CONSTRUCTION TYPE: TYPE III-B SPRINKLERS: YES UTILITY: SCE GOVERNING CODES:- THESE DRAWINGS AND THIS PROJECT COMPLIES WITH THE FOLLOWING CODES: 2020 NATIONAL ELECTRICAL CODE 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA GREEN CODE 2022 CALIFORNIA FIRE CODE ALL OTHER ORDINANCE ADOPTED BY THE LOCAL GOVERNING AGENCIES SCOPE OF WORK: SUBMITTAL FOR CITY BUILDING AND ELECTRICAL REVIEW THIS PROJECT ENTAILS THE INSTALLATION OF ROOF MOUNTED PHOTOVOLTAIC (PV) SYSTEM. THIS SYSTEM WAS DESIGNED IN COORDINATION WITH THE BUILDING ARCHITECT AND ENGINEERS OF RECORD. MODULES: (97) PHONO SOLAR PS585M8GFH-24/TNH 585W INVERTERS: (2) CPS SCA25KTL-DO-R/US-480 DC SYSTEM SIZE: 56.745 KW AC SYSTEM SIZE: 50.00 KW CO V E R P A G E INTERCONNECTION TYPE: NEM SHEET INDEX S.NO SHEET NAME PV-1 COVER PAGE PV-2 SITE PLAN PV-3 ROOF PV LAYOUT PV-4 ELECTRICAL LINE DIAGRAM PV-5 SPEC SHEET PV-6 ATTACHMENT DETAIL PV-7 REFERENCE SHEET: FRAMING DETAIL SOUTH COAST TECHNOLOGY CENTER SOLAR PV SYSTEM (56.745 KW DC STC / 50.00 KW AC CEC) VICINITY MAP AERIAL MAP ELECTRICAL CONSTRUCTION GENERAL NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE NEC (NATIONAL ELECTRIC CODE), NFPA (NATIONAL FIRE PROTECTION ASSOCIATION), AND ALL APPLICABLE LOCAL, STATE, AND FEDERAL CODES, LAWS AND REGULATIONS. 2. ALL WORK SHALL CONFORM TO APPLICABLE STATE AND FEDERAL SAFETY CODES INCLUDING OSHA AND CAL OSHA. NO "HOT" WORK IS AUTHORIZED. ALL "HOT" WORK SHALL BE APPROVED IN WRITING WITH THE GENERAL CONTRACTOR AND OWNER. 3. COORDINATE ALL WORK WITH ARCHITECTURAL, MECHANICAL AND STRUCTURAL DRAWINGS, INSTALL ALL WORK TO CLEAR NEW AND EXISTING ARCHITECTURAL AND STRUCTURAL MEMBERS. NO ITEM SUCH AS A PIPE, DUCT, ETC. SHALL BE IN CONTACT WITH ANY ELECTRICAL EQUIPMENT. 4. CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY AND SECURITY OF THE WORKSITE. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. 5. NOTIFY THE PRIME CONTRACTOR OR OWNER IMMEDIATELY AFTER DISCOVERING ANY HAZARDOUS MATERIAL. 6. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND WORK INCLUDED. VERIFY THE EXACT LOCATIONS AND CONDITIONS OF ALL EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS PRIOR TO ANY WORK. LOCATIONS FOR EQUIPMENT SHALL BE TAKEN FROM THE OTHER SHEETS WHERE THEY OCCUR. EXTEND WIRING FROM ALL JUNCTION BOXES, CONTROL PANELS, PUMPS, RECEPTACLES, SWITCHES, ETC. AND MAKE ALL FINAL CONNECTIONS TO THE EQUIPMENT AS REQUIRED. 7. THE INTENT OF THESE DRAWINGS IS FOR A COMPLETE ELECTRICAL SYSTEM. ANY ERRORS OR UNCERTAINTY SHALL BE BROUGHT TO THE ATTENTION OF THE PRIME CONTRACTOR AND ENGINEER AS SOON AS FOUND. 8. THE COMPLETE ELECTRICAL INSTALLATION SHALL BE TESTED AS A COMPLETE WORKING SYSTEM. 9. RESTORE ALL DAMAGES RESULTING FROM WORK AND LEAVE PREMISES IN CLEAN CONDITION WHEN FINISHED WITH 10. FIRE STOP ALL PENETRATIONS THROUGH FIRE RATED SURFACES. 11. ALL NEW CIRCUIT BREAKERS SHALL BE RATED 10,000 AIC OR HIGHER 12. ALL CONDUITS SHALL BE EMT, INTERMEDIATE METAL CONDUIT, OR RIGID STEEL. MINIMUM SIZE SHALL BE 1/2". ALL CONDUIT, BOXES, AND ELECTRICAL FITTINGS SHALL BE STEEL. 13. DO NOT USE THE WORKING SPACE WITHIN ANY EXIT SIGN OR ASSOCIATED JUNCTION BOX FOR ANY OTHER CIRCUIT. 14. PROVIDE EXPANSION AND DEFLECTION FITTINGS IN CONDUITS CROSSING BUILDING EXPANSION AND SEISMIC JOINTS. 15. PROVIDE JUNCTION AND/OR PULL BOXES WHEN NECESSARY OR REQUIRED BY NEC. SHALL BE USED. 16. INSTALL GREEN INSULATED GROUND WIRE IN ALL CIRCUITS. SIZE PER NEC REQUIREMENTS OR THE SAME AS PHASE CONDUCTORS, WHICHEVER IS LARGER. UNLESS INDICATED OTHERWISE. 17. ALL NEW WIRING, CONDUIT, AND JUNCTION BOXES SHALL BE CONCEALED WITHIN NEW WALLS, CEILINGS OR FLOOR SPACES. SURFACE MOUNT CONDUIT ON OLD WALLS AND CEILINGS. RUN ALL SURFACE RACEWAY TIGHT TO THE STRUCTURE, PARALLEL TO BUILDING LINES. 18. NO FOREIGN EQUIPMENT SHALL BE LOCATED WITHIN THE SPACE ABOVE OR BELOW THE ELECTRIC PANELS. 19. PROVIDE SIGNAGE ON ALL ELECTRIC PANELS TO KEEP THE SPACE 36" IN FRONT OF THE PANELS FREE OF OBSTRUCTIONS. 20. PROVIDE WARNING LABEL ON ALL PANELS "WARNING, ELECTRICAL ARC FLASH HAZARD, PERSONAL PROTECTION EQUIPMENT REQUIRED, FAILURE TO COMPLY CAN RESULT IN INJURY OR DEATH, REFER TO NFPA 70E." WHERE THE TERMINAL OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A WARNING SIGN SHALL BE MOUNTED ON OR ADJACENT TO THE DISCONNECTING MEANS. THE SIGN SHALL BE CLEARLY LEGIBLE AND HAVE THE FOLLOWING WORDS OR EQUIVALENT: "WARNING - ELECTRIC SHOCK HAZARD, DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND THE LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION." 21. UPDATE PANEL BOARD DIRECTORY AS CIRCUITS ARE INSTALLED. PREPARE NEW TYPE WRITTEN PANEL SCHEDULES. 22. ALL EXTERIOR EQUIPMENT SHALL BE IN WEATHERPROOF (NEMA 3R) ENCLOSURES. ALL NEW WIRING SHALL BE IN CONDUIT, SUITABLE FOR SUN EXPOSURE AND WET LOCATIONS. FIELD APPLIED COATINGS ARE NOT ACCEPTABLE. 23. ALL MARKING SHALL BE PER CODE REQUIREMENTS. 24. INVERTERS MUST COMPLY WITH UL 1741 TO PREVENT ISLANDING ON POWER FAILURE. THE INVERTERS SHALL NOT PUT POWER ON TO THE GRID IF THE GRID IS OFF-LINE. 25. NOTHING IN THESE PLANS SHALL BE CONSTRUED TO CONTRADICT NEC, UL OR LOCAL CODES. 26. ALL SYSTEM COMPONENTS (MODULES AND INVERTERS ETC.) SHALL BE UL LISTED, UL2703 AND UL1703. 27. MOUNT TO ROOF USING UL APPROVED MOUNTING HARDWARE. FOLLOW MANUFACTURERS INSTALLATION MANUALS. 28. MARK THE NEC REQUIRED CLEAR SPACE ON THE FLOOR IN FRONT OF ALL DEVICES BEING INSTALLED. 29. SUPPORT ALL ROOF MOUNTED CONDUIT WITH FOAM "SLEEPERS" IN UL APPROVED SYSTEM. 30. PV MODULES SHALL NOT BE INSTALLED OVER ANY PLUMBING OR MECHANICAL VENTS, EXHAUSTS OR CHIMNEYS. 31. REMOVAL OF INVERTER, METER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. 32. ALL PV MODULES AND ASSOCIATED EQUIPMENT SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE AND ACCESS BY UNQUALIFIED PERSONS. 33. UTILITY IS 277/480V, 3 PHASE, 4W. PV SYSTEM IS UTILITY INTERACTIVE. 34. SYSTEM CARRIES A "CLASS A" FIRE RATING. HSA & ASSOCIATES, INC. CONSULTING STRUCTURAL ENGINEERS APPROVED BY DATE REVIEWED FOR USE ON SUBJECT JOB ONLY NOT RESPONSIBLE FOR: QUANTITIES, OMISSIONS OR DEVIATIONS FROM CONTRACT DOCUMENTS. CONTRACTOR TO VERIFY ALL DIMENSIONS ON JOBS. MAKE CORRECTION AS NOTED REJECTED REVISE AND RESUBMIT FOR INFORMATION ONLY 4 fady 5/8/2025 430'-9" 47 2 ' - 3 " 482'-11"7'-3" 44 3 ' - 7 " 21'-9" 49'- 2 " UM MD P 4/30/2025 KG PV-2 Date Plotted: Drawn By Checked By SHEET NO. SHEET NAME SIGNATURE & SEAL Project Number 200 S. San Pedro St #500 Los Angeles, CA 90012, USA info@calsolarinc.com www.calsolarinc.com C-46 SOLAR LIC. #1004246 800-784-7612 No.Description Date 36 0 0 , S S U S A N S T , SA N T A A N A , CA 92 7 0 4 SO U T H C O A S T T E C H N O L O G Y C E N T E R (56 . 7 4 5 K W D C S T C / 50 . 0 0 0 K W A C C E C ) SH 1 REVISION 04/16/2025 1 SITE PLAN SCALE: 3/64"=1'-0"_XREF PV-2 SI T E P L A N MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = 97 MODULES MODULE TYPE = PHONO SOLAR PS585M8GFH-24/TNH 585W WEIGHT = 70.55 LBS / 32.00 KG. MODULE DIMENSIONS = 89.69" X 44.65" = 27.81 SF PV SCHEDULE BUILDING PANEL COUNT ROOF TILT MODULE TILT-UP AZIMUTH #1 97 0°10°180° 72" FIRE ACCESS PATHWAY (TYP.) (E) UTILITY METER (E) MAIN SWITCHBOARD "MSB" ELECTRICAL ROOM ARRAY AREA & ROOF AREA CALC'S BUILDING # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 97 2697.57 30664.94 9 BUILDING #1 (97) PHONO SOLAR PS585M8GFH-24/TNH 585W MODULES TILT - 0° TILT UP - 10° AZIMUTH - 180° W LAKE CENTER DR S S U S A N S T 72" FIRE SETBACK 72 " F I R E S E T B A C K 72 " F I R E S E T B A C K 72 " F I R E S E T B A C K 72" FIRE SETBACK 72 " F I R E S E T B A C K 72" FIRE SETBACK 72 " F I R E S E T B A C K 72 " F I R E S E T B A C K 72" FIRE SETBACK DR I V E W A Y DRIVEWAY DR I V E W A Y DRIVEWAY DR I V E W A Y PROPERTY LINE PR O P E R T Y L I N E PROPERTY LINE PR O P E R T Y L I N E NOTE: RAPID SHUT DOWN GOVERNED BY UL 3741 FOR CPS AND PANEL CLAW. ARASH ZANDIEH 2025.07.13 21:45:00 UM MD P AC D LC INV IN V 4/30/2025 KG PV-3 Date Plotted: Drawn By Checked By SHEET NO. SHEET NAME SIGNATURE & SEAL Project Number 200 S. San Pedro St #500 Los Angeles, CA 90012, USA info@calsolarinc.com www.calsolarinc.com C-46 SOLAR LIC. #1004246 800-784-7612 No.Description Date 36 0 0 , S S U S A N S T , SA N T A A N A , CA 92 7 0 4 SO U T H C O A S T T E C H N O L O G Y C E N T E R (56 . 7 4 5 K W D C S T C / 50 . 0 0 0 K W A C C E C ) SH 1 REVISION 04/16/2025 1 ROOF PV LAYOUT SCALE: 1/16" = 1'PV-3 RO O F P V L A Y O U T 2 ELECTRICAL ROOM SCALE: 1/4" = 1'-0"PV-3 (E) MAIN SWITCHBOARD 'MSB' (N) PV AC DISCONNECT (E) METER NOTE: EMT CONDUIT ON THE ROOF TO BE RAN AT MINIMUM 7/8" HEIGHT FROM THE ROOF SURFACE. NOTE: EXACT JUNCTION BOX LOCATIONS TO BE DETERMINED IN FIELD. ALL CONDUIT IS TO NOT BE ATTACHED TO TILT-UP PANELS.PER CFC 1205.3.1 EXCEPTION = 72" FIRE SETBACK PV SCHEDULE BUILDING PANEL COUNT ROOF TILT MODULE TILT-UP AZIMUTH #1 97 0°10°180°- DC CONDUIT - AC CONDUIT - COMM. CABLE - STRING LEGENDS W LAKE CENTER DR S S U S A N S T (N) INVERTER #2 (N) INVERTER #1 (1) 1-1/4" EMT AC CONDUIT (~100') (1) 1" EMT - COMM. CABLE (~100') 72 FIRE SETBACK 72 FIRE SETBACK 72 F I R E S E T B A C K 72 F I R E S E T B A C K 72 F I R E S E T B A C K 72 F I R E S E T B A C K 72 F I R E S E T B A C K 72 F I R E S E T B A C K 72 F I R E S E T B A C K ST R I N G # 1 . 1 ST R I N G # 1 . 2 ST R I N G # 1 . 3 ST R I N G # 2 . 1 ST R I N G # 2 . 2 ST R I N G # 2 . 3 (N) PV LOAD CENTER (CANNOT BE SEEN ABOVE PARAPET WALL) (NOT TO BE ATTACHED TO TILT-UP PANEL) (1) 1-1/4" EMT AC CONDUIT (~100') (1) 1" EMT - COMM. CABLE (~100') STUB-UP LOCATION (1) 1-1/4" EMT AC CONDUIT (~80') (1) 1" EMT - COMM. CABLE (~80') (E) MAIN SWITCHBOARD 'MSB' (N) PV AC DISCONNECT (E) METER EACH INVERTER WILL HAVE A U-ANCHOR ATTACHMENT 'L' RAIL INSTALLATION: USE THE OUTER SET OF HOLES WHEN INSTALLING RAILS BETWEEN MODULES. RAIL ON “L” SPACING IS ALWAYS ON TOP OF RAIL ON “S” SPACING. THIS INSTALLATION SEQUENCE IS CRITICAL TO SYSTEM PERFORMANCE. FOR MORE INFORMATION REVIEW THE INSTALLATION MANUAL AND VIDEOS. A (REPEAT DIMENSION EAST-WEST) PL (PANEL LENGTH) M (PROJECTED PANEL WIDTH) B (REPEAT DIMENSION NORTH-SOUTH) C J PT P D PW D ° O W K X 18 mm (0.709 in)N G 32 . 9 m m ( 1 . 2 9 5 i n ) S (ON-MODULE BASE SPACING) L (BETWEEN-MODULE BASE SPACING)R AEBE RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: ARRAY TOP VIEW B NTSSCALE: ARRAY CROSS SECTION VIEW A NTS SCALE: RAIL DETAIL C NTS RACKING CONSTRUCTION SET Calsolar inc South Coast Technology Center 3600 S Susan St, Santa Ana, CA 92704, USA 0 25.02.04.0 v3.0.9406.0.5 CM INSTALLED ARRAY DIMENSIONS A B C D G J K M N O P R W X Theta (DEG)D/J (#:1)G.C.R.* mm 2296 1398 121 278 116 177 209 1120 81 59 92 516 253 137 8.99 1.57 0.81UNITS inches 90.39 55.05 4.75 10.96 4.56 6.97 8.23 44.10 3.20 2.31 3.61 20 5/16 9.95 5.39 8.99 1.57 0.81 * G.C.R = (PW) / B INSTALLATION MEASUREMENTS AEBE S L CAM SPACING* mm 486 1246 1050 53UNITS inches 19 1/8 49 1/16 41 5/16 2 1/8 *CAM SPACING SHOWN ON ASSEMBLIES PAGE. MODULE DIMENSIONS PL PW PT mm 2278 1134 35UNITS inches 89.69 44.65 1.38 PC-4 PC-4 PC-4 TYPICAL ARRAY DIMENSIONS PC-4 APPROVED FOR CONSTRUCTION 0 In i t i a l L a y o u t AW 20 2 5 - 0 5 - 0 2 25-0242-3336 5/7/2025 TROY E.TURLEY 4/30/2025 KG PV-4 Date Plotted: Drawn By Checked By SHEET NO. SHEET NAME SIGNATURE & SEAL Project Number 200 S. San Pedro St #500 Los Angeles, CA 90012, USA info@calsolarinc.com www.calsolarinc.com C-46 SOLAR LIC. #1004246 800-784-7612 No.Description Date 36 0 0 , S S U S A N S T , SA N T A A N A , CA 92 7 0 4 SO U T H C O A S T T E C H N O L O G Y C E N T E R (56 . 7 4 5 K W D C S T C / 50 . 0 0 0 K W A C C E C ) SH 1 REVISION 04/16/2025 (97) PHONO SOLAR PS585M8GFH-24/TNH 585W (05) STRING OF 16 MODULES CONNECTED IN SERIES (01) STRING OF 17 MODULES CONNECTED IN SERIES DI A G R A M EL E C T R I C A L L I N E PV Module Specifications Manufacturer/ Model Number: PHONO SOLAR PS585M8GFH-24/TNH (585W) Weight:70.55 lbs Dimensions:89.69"L x 44.65"W x 1.18"D (In Inch) Power @ STC:585 Watts Rated Voltage (Vmpp)43.40 Volt Rated Current (Impp)13.48 Amps Open-Circuit Voltage (Voc)52.68 Volt Short-Circuit Current (Isc)14.18 Amps Voc Temp Coeff:-0.25 %/°C 2 ELECTRICAL CALCULATIONS SCALE: NTSPV-4 Inverter specifications Manufacturer/ Model Number:CPS SCA25KTL-DO-R/US-480 Nominal ac power (KW)25.0 Nominal output voltage (V)560 Nominal output current (per phase) (A)30.5 Max dc input voltage (V)1000 CEC efficiency (%)98 Maximum input power (W)37.50 Maximum output power (W)25.0 1.UTILITY IS 277/480V, 3Ø, 4W 2.PV SYSTEM IS UTILITY INTERACTIVE 3.INVERTER IS FULLY COMPLIANT WITH UL 1741 CONCERNING LACK OF INTERACTIVE SYSTEM POWER. 4.ALL PV SYSTEM COMPONENTS SHALL BE LISTED BY A RECOGNIZED TESTING AGENCY. 5.WIRING MATERIAL SHALL BE SUITABLE FOR THE SUN EXPOSURE AND WET LOCATIONS. 6.WHERE THE TERMINAL OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A WARNING SIGN SHALL BE MOUNTED ON OR ADJACENT TO THE DISCONNECTING MEANS. THE SIGN SHALL BE CLEARLY LEGIBLE AND HAVE THE FOLLOWING WORDS OR EQUIVALENT: “ WARNING – ELECTRIC SHOCK HAZARD, DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION.” 7.SIGNS SHALL BE POSTED ADJACENT TO EACH PV DISCONNECT AND INVERTER TO INDICATE, “ PHOTOVOLTAIC SYSTEM.” 8.ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING MATERIALS SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. 9.IN ONE- AND TWO-FAMILY DWELLING, LIVE PARTS IN PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150 VOLTS TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED. 10.ALL FIELD INSTALLED JUNCTION, PULL AND OUTLET BOXES LOCATED BEHIND MODULES OR PANELS SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A MODULE(S) OR PANEL(S) SECURED BY REMOVABLE FASTENERS. 11.PRESSURE TERMINALS TIGHTENED TO THE RECOMMENDED TORQUE SPECIFICATION. 12.CRIMP-ON TERMINALS LISTED AND INSTALLED WITH LISTED CRIMPING TOOLS BY THE SAME MANUFACTURER. 13.USER ACCESSIBLE FUSES IN “ TOUCH-SAFE” HOLDERS OR CAPABLE OF BEING CHANGED WITHOUT TOUCHING LIVE CONTACTS. ELECTRICAL NOTES 1 ELECTRICAL LINE DIAGRAM SCALE: NTSPV-4 WIRE AND CONDUIT SCHEDULE TAG CONDUCTOR MATERIAL QUANTITY IN PARALLEL CONDUCTOR QUANTITY CONDUCTOR WIRE SIZE CONDUCTOR TYPE NEUTRAL QUANTITY GROUND QUANTITY NEUTRAL & GROUNDING WIRE SIZE NEUTRAL TYPE GROUND TYPE CONDUIT SIZE CONDUIT TYPE MAX APPROX LENGTH (FT.) CONDUIT FILL % VOLTAGE DROP % DC1 CU 1 2 10 AWG PV-WIRE N/A 1 6 AWG N/A BARE CU N/A N/A 50 0.00%0.22% AC1 AL 1 3 6 AWG THWN-2 1 1 8 AWG THWN-2 THWN-2 1-1/4"EMT 100 15.06%0.89% AC2 AL 1 3 2 AWG THWN-2 1 1 6 AWG THWN-2 THWN-2 1-1/4"EMT 80 30.00%0.56% AC3 CU 1 3 4 AWG THWN-2 1 1 8 AWG THWN-2 THWN-2 1-1/4"RMC 16.50 21.00%0.11% WIRE SIZE CALCULATION TAG CONDUCTOR SPECIFICATIONS REQUIRED CONDUCTOR AMPACITY CONDUCTOR TEMP. DERATING CONDUCTOR AMPACITY CALCULATION AMPACITY CHECK QTY IN PARALLEL CONDUCTO R MATERIAL CONDUCTO R QUANTITY CONDUCTO R WIRE SIZE WIRE TEMP RATING (°C) AMPACITY PER 310.16 MAX INV. OR COMPONEN T CURRENT (A) COUNT OPERATIO N REQUIRE D AMPACITY 2% AVG HIGH TEMP(°C) AMPACITY CORRECTION CONDUCTO R AMPACITY TEMP. DERATE CONDUI T FILL DERATE CORRECTE D AMPACITY REQUIRED AMPACITY CORRECTE D AMPACITY DC1 1 CU 2 10 AWG 90 40 17.73 X 1.25 =22.16 31 0.96 40 X 0.96 X 1.00 =38.40 22.16 <38.40 AC1 1 AL 3 6 AWG 75 50 30.50 X 1.25 =38.13 31 0.96 50 X 0.96 X 1.00 =48.00 38.13 <48.00 AC2 1 AL 3 2 AWG 75 90 61.00 X 1.25 =76.25 31 0.96 90 X 0.96 X 1.00 =86.40 76.25 <86.40 AC3 1 CU 3 4 AWG 75 85 61.00 X 1.25 =76.25 31 0.96 85 X 0.96 X 1.00 =81.60 76.25 <81.60 FAULT CURRENT TAG AC3 AC2 I (TOTAL S.C.)65000 32229 VOLTAGE 480 480 LENGTH 16.50 80 QTY (PER PHASE)1 1 SIZE 4 2 TYPE CU AL CONDUIT 3 SINGLE CONDUCTORS 3 SINGLE CONDUCTORS WIRE STEEL STEEL FAULT CURRENT (A)32229 9193 G N = DC AC AC1 (1) #10 AWG USE-2/PV WIRE (1) #10 AWG USE-2/PV WIRE (1) #6 BARE COPPER = DC AC INVERTER #2 CPS SCA25KTL-DO-R/US-480 INVERTER, 277/480V, 3Ø, 4W, NEMA 4X, UL LISTED (ON ROOF/ON BENTEK STRUCTURE) INVERTER #1 CPS SCA25KTL-DO-R/US-480 INVERTER, 277/480V, 3Ø, 4W, NEMA 4X, UL LISTED (ON BENTEK STRUCTURE) 40A 40A (3) #4 AWG AL THWN-2 (1) #4 AWG AL THWN-2 NEU (1) #4 AWG AL THWN-2 EGC 1-1/4" EMT CONDUIT (DISTANCE: 100 FT) (CONDUIT BY CALSOLAR) 21 1615 1615 DC1 (N) PV AC DISCONNECT: 100A, 277/480V, 3Ø, 4W, NEMA 1, FUSIBLE, VISIBLE, J-RATED FUSE, UL LISTED Is.c. = 32,229A 80A FUSE AC2 AC3 21 21 1615 21 1615 21 21 1615 1716 (N) PV LOAD CENTER, 100A, 277/480V, 3Ø, 4W, 14KAIC, NEMA 3R, UL LISTED Is.c. = 9,193A (3) #2 AWG AL THWN-2 (1) #4 AWG AL THWN-2 NEU (1) #4 AWG AL THWN-2 EGC 1-1/4" EMT CONDUIT & 1" EMT CONDUIT FOR DATA CABLE (DISTANCE: 80 FT THROUGH STUB UP) (CONDUIT BY OTHERS) (3) #3/0 AWG CU THWN-2 (1) #4 AWG CU THWN-2 NEU (1) #6 AWG CU THWN-2 GEC 2-1/2" RMC CONDUIT (DISTANCE: 16.5 FT) (CONDUIT BY CALSOLAR) 1" EMT CONDUIT TO ELECTRICAL ROOM COMM CABLE CO M M C A B L E AC1 (3) #4 AWG AL THWN-2 (1) #4 AWG AL THWN-2 NEU (1) #4 AWG AL THWN-2 EGC 1-1/4" EMT CONDUIT (DISTANCE: 100 FT) (CONDUIT BY CALSOLAR) M G NGRID EXISTING WIRING MAIN SWITCHBOARD 'MSB', 2000A, 277/480V, 3Ø, 4W, 65KAIC (E) GROUNDING ELECTRODE SYSTEM 2000A 3P 65KAIC CT'S 2000A BUS 200A 3P PV SYSTEM BREAKER BY OTHERSON ROOF ELECTRICAL ROOM GFP ARC FLASH REDUCT 4/30/2025 KG PV-6 Date Plotted: Drawn By Checked By SHEET NO. SHEET NAME SIGNATURE & SEAL Project Number 200 S. San Pedro St #500 Los Angeles, CA 90012, USA info@calsolarinc.com www.calsolarinc.com C-46 SOLAR LIC. #1004246 800-784-7612 No.Description Date 36 0 0 , S S U S A N S T , SA N T A A N A , CA 92 7 0 4 SO U T H C O A S T T E C H N O L O G Y C E N T E R (56 . 7 4 5 K W D C S T C / 50 . 0 0 0 K W A C C E C ) SH 1 REVISION 04/16/2025 AT T A C H M E N T D E T A I L RE V DE S C R I P T I O N PR E P CH E C K DA T E PANELCLAW, INCALL INFORMATION CONTAINED WITHIN THISDOCUMENT IS PROPERTY OF PANELCLAW, INC.THE PURPOSE OF THIS DOCUMENT IS TOFACILITATE THE INSTALLATION OF PANELCLAWSOLAR PHOTOVOLTAIC MOUNTING SYSTEMS. DONOT COPY OR DISTRIBUTE WITHOUT PERMISSION. C SCALE: 0"1/2"1"2" ORIGINAL SIZE 36"X24" SHEET SIZE ARCH "D" 1600 OSGOOD ST. SUITE 2023 NORTH ANDOVER, MA 01845 TEL: 978.688.4900 www.panelclaw.com STAMP: PREPARED FOR: PROJECT: LOCATION: REVISION:SHEET: 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 SHEET TITLE: A B C D A B C D RACKING CONSTRUCTION SET SCALE: # RACKING CONSTRUCTION SET NOTES: 1.ALL DIMENSIONS SHOWN ARE BASED UPON INFORMATION PROVIDED TO PANELCLAW. FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION OF THE SOLAR ARRAY. NOTIFY PANELCLAW OF ANY DISCREPANCIES. APPROVED FOR CONSTRUCTION Calsolar inc South Coast Technology Center 3600 S Susan St, Santa Ana, CA 92704, USA ARRAY SITE MAP PC-30 25.02.04.0 v3.0.9406.0.5 CM ROOF NAME ROOF SETBACK (FT.) ROOF HEIGHT (FT) PARAPET HEIGHT (FT) ROOF TILT (DEG) Roof 1 6.00 48.00 4.0 1 KEEPOUT NAME KEEPOUT CLEARANCE (FT.) KEEPOUT HEIGHT (IN.) Group 1 4 6 Group 2 4 24 Group 3 4 60 3 0 In i t i a l L a y o u t AW 20 2 5 - 0 5 - 0 2 45' 71' 320' 50' 10' 95' 10' 63' 10' 95' 10' 50' 320' 71' 45' 211' 1 2 25-0242-3336 5/7/2025 TROY E.TURLEY UM MD P AC D LC INV IN V 4/30/2025 KG PV-3 Date Plotted: Drawn By Checked By SHEET NO. SHEET NAME SIGNATURE & SEAL Project Number 200 S. San Pedro St #500 Los Angeles, CA 90012, USA info@calsolarinc.com www.calsolarinc.com C-46 SOLAR LIC. #1004246 800-784-7612 No.Description Date 36 0 0 , S S U S A N S T , SA N T A A N A , CA 92 7 0 4 SO U T H C O A S T T E C H N O L O G Y C E N T E R (56 . 7 4 5 K W D C S T C / 50 . 0 0 0 K W A C C E C ) SH 1 REVISION 04/16/2025 1 ROOF PV LAYOUT SCALE: 1/16" = 1'PV-3 RO O F P V L A Y O U T 2 ELECTRICAL ROOM SCALE: 1/4" = 1'-0"PV-3 (E) MAIN SWITCHBOARD 'MSB' (N) PV AC DISCONNECT (E) METER NOTE: EMT CONDUIT ON THE ROOF TO BE RAN AT MINIMUM 7/8" HEIGHT FROM THE ROOF SURFACE. NOTE: EXACT JUNCTION BOX LOCATIONS TO BE DETERMINED IN FIELD. ALL CONDUIT IS TO NOT BE ATTACHED TO TILT-UP PANELS.PER CFC 1205.3.1 EXCEPTION = 72" FIRE SETBACK PV SCHEDULE BUILDING PANEL COUNT ROOF TILT MODULE TILT-UP AZIMUTH #1 97 0°10°180°- DC CONDUIT - AC CONDUIT - COMM. CABLE - STRING LEGENDS W LAKE CENTER DR S S U S A N S T (N) INVERTER #2 (N) INVERTER #1 (1) 1-1/4" EMT AC CONDUIT (~100') (1) 1" EMT - COMM. CABLE (~100') 72 FIRE SETBACK 72 FIRE SETBACK 72 F I R E S E T B A C K 72 F I R E S E T B A C K 72 F I R E S E T B A C K 72 F I R E S E T B A C K 72 F I R E S E T B A C K 72 F I R E S E T B A C K 72 F I R E S E T B A C K ST R I N G # 1 . 1 ST R I N G # 1 . 2 ST R I N G # 1 . 3 ST R I N G # 2 . 1 ST R I N G # 2 . 2 ST R I N G # 2 . 3 (N) PV LOAD CENTER (CANNOT BE SEEN ABOVE PARAPET WALL) (NOT TO BE ATTACHED TO TILT-UP PANEL) (1) 1-1/4" EMT AC CONDUIT (~100') (1) 1" EMT - COMM. CABLE (~100') STUB-UP LOCATION (1) 1-1/4" EMT AC CONDUIT (~80') (1) 1" EMT - COMM. CABLE (~80') (E) MAIN SWITCHBOARD 'MSB' (N) PV AC DISCONNECT (E) METER EACH INVERTER WILL HAVE A U-ANCHOR ATTACHMENT 4/30/2025 KG PV-4 Date Plotted: Drawn By Checked By SHEET NO. SHEET NAME SIGNATURE & SEAL Project Number 200 S. San Pedro St #500 Los Angeles, CA 90012, USA info@calsolarinc.com www.calsolarinc.com C-46 SOLAR LIC. #1004246 800-784-7612 No.Description Date 36 0 0 , S S U S A N S T , SA N T A A N A , CA 92 7 0 4 SO U T H C O A S T T E C H N O L O G Y C E N T E R (56 . 7 4 5 K W D C S T C / 50 . 0 0 0 K W A C C E C ) SH 1 REVISION 04/16/2025 (97) PHONO SOLAR PS585M8GFH-24/TNH 585W (05) STRING OF 16 MODULES CONNECTED IN SERIES (01) STRING OF 17 MODULES CONNECTED IN SERIES DI A G R A M EL E C T R I C A L L I N E PV Module Specifications Manufacturer/ Model Number: PHONO SOLAR PS585M8GFH-24/TNH (585W) Weight:70.55 lbs Dimensions:89.69"L x 44.65"W x 1.18"D (In Inch) Power @ STC:585 Watts Rated Voltage (Vmpp)43.40 Volt Rated Current (Impp)13.48 Amps Open-Circuit Voltage (Voc)52.68 Volt Short-Circuit Current (Isc)14.18 Amps Voc Temp Coeff:-0.25 %/°C 2 ELECTRICAL CALCULATIONS SCALE: NTSPV-4 Inverter specifications Manufacturer/ Model Number:CPS SCA25KTL-DO-R/US-480 Nominal ac power (KW)25.0 Nominal output voltage (V)560 Nominal output current (per phase) (A)30.5 Max dc input voltage (V)1000 CEC efficiency (%)98 Maximum input power (W)37.50 Maximum output power (W)25.0 1.UTILITY IS 277/480V, 3Ø, 4W 2.PV SYSTEM IS UTILITY INTERACTIVE 3.INVERTER IS FULLY COMPLIANT WITH UL 1741 CONCERNING LACK OF INTERACTIVE SYSTEM POWER. 4.ALL PV SYSTEM COMPONENTS SHALL BE LISTED BY A RECOGNIZED TESTING AGENCY. 5.WIRING MATERIAL SHALL BE SUITABLE FOR THE SUN EXPOSURE AND WET LOCATIONS. 6.WHERE THE TERMINAL OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A WARNING SIGN SHALL BE MOUNTED ON OR ADJACENT TO THE DISCONNECTING MEANS. THE SIGN SHALL BE CLEARLY LEGIBLE AND HAVE THE FOLLOWING WORDS OR EQUIVALENT: “ WARNING – ELECTRIC SHOCK HAZARD, DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION.” 7.SIGNS SHALL BE POSTED ADJACENT TO EACH PV DISCONNECT AND INVERTER TO INDICATE, “ PHOTOVOLTAIC SYSTEM.” 8.ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING MATERIALS SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. 9.IN ONE- AND TWO-FAMILY DWELLING, LIVE PARTS IN PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150 VOLTS TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED. 10.ALL FIELD INSTALLED JUNCTION, PULL AND OUTLET BOXES LOCATED BEHIND MODULES OR PANELS SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A MODULE(S) OR PANEL(S) SECURED BY REMOVABLE FASTENERS. 11.PRESSURE TERMINALS TIGHTENED TO THE RECOMMENDED TORQUE SPECIFICATION. 12.CRIMP-ON TERMINALS LISTED AND INSTALLED WITH LISTED CRIMPING TOOLS BY THE SAME MANUFACTURER. 13.USER ACCESSIBLE FUSES IN “ TOUCH-SAFE” HOLDERS OR CAPABLE OF BEING CHANGED WITHOUT TOUCHING LIVE CONTACTS. ELECTRICAL NOTES 1 ELECTRICAL LINE DIAGRAM SCALE: NTSPV-4 WIRE AND CONDUIT SCHEDULE TAG CONDUCTOR MATERIAL QUANTITY IN PARALLEL CONDUCTOR QUANTITY CONDUCTOR WIRE SIZE CONDUCTOR TYPE NEUTRAL QUANTITY GROUND QUANTITY NEUTRAL & GROUNDING WIRE SIZE NEUTRAL TYPE GROUND TYPE CONDUIT SIZE CONDUIT TYPE MAX APPROX LENGTH (FT.) CONDUIT FILL % VOLTAGE DROP % DC1 CU 1 2 10 AWG PV-WIRE N/A 1 6 AWG N/A BARE CU N/A N/A 50 0.00%0.22% AC1 AL 1 3 6 AWG THWN-2 1 1 8 AWG THWN-2 THWN-2 1-1/4"EMT 100 15.06%0.89% AC2 AL 1 3 2 AWG THWN-2 1 1 6 AWG THWN-2 THWN-2 1-1/4"EMT 80 30.00%0.56% AC3 CU 1 3 4 AWG THWN-2 1 1 8 AWG THWN-2 THWN-2 1-1/4"RMC 16.50 21.00%0.11% WIRE SIZE CALCULATION TAG CONDUCTOR SPECIFICATIONS REQUIRED CONDUCTOR AMPACITY CONDUCTOR TEMP. DERATING CONDUCTOR AMPACITY CALCULATION AMPACITY CHECK QTY IN PARALLEL CONDUCTO R MATERIAL CONDUCTO R QUANTITY CONDUCTO R WIRE SIZE WIRE TEMP RATING (°C) AMPACITY PER 310.16 MAX INV. OR COMPONEN T CURRENT (A) COUNT OPERATIO N REQUIRE D AMPACITY 2% AVG HIGH TEMP(°C) AMPACITY CORRECTION CONDUCTO R AMPACITY TEMP. DERATE CONDUI T FILL DERATE CORRECTE D AMPACITY REQUIRED AMPACITY CORRECTE D AMPACITY DC1 1 CU 2 10 AWG 90 40 17.73 X 1.25 =22.16 31 0.96 40 X 0.96 X 1.00 =38.40 22.16 <38.40 AC1 1 AL 3 6 AWG 75 50 30.50 X 1.25 =38.13 31 0.96 50 X 0.96 X 1.00 =48.00 38.13 <48.00 AC2 1 AL 3 2 AWG 75 90 61.00 X 1.25 =76.25 31 0.96 90 X 0.96 X 1.00 =86.40 76.25 <86.40 AC3 1 CU 3 4 AWG 75 85 61.00 X 1.25 =76.25 31 0.96 85 X 0.96 X 1.00 =81.60 76.25 <81.60 FAULT CURRENT TAG AC3 AC2 I (TOTAL S.C.)65000 32229 VOLTAGE 480 480 LENGTH 16.50 80 QTY (PER PHASE)1 1 SIZE 4 2 TYPE CU AL CONDUIT 3 SINGLE CONDUCTORS 3 SINGLE CONDUCTORS WIRE STEEL STEEL FAULT CURRENT (A)32229 9193 G N = DC AC AC1 (1) #10 AWG USE-2/PV WIRE (1) #10 AWG USE-2/PV WIRE (1) #6 BARE COPPER = DC AC INVERTER #2 CPS SCA25KTL-DO-R/US-480 INVERTER, 277/480V, 3Ø, 4W, NEMA 4X, UL LISTED (ON ROOF/ON BENTEK STRUCTURE) INVERTER #1 CPS SCA25KTL-DO-R/US-480 INVERTER, 277/480V, 3Ø, 4W, NEMA 4X, UL LISTED (ON BENTEK STRUCTURE) 40A 40A (3) #4 AWG AL THWN-2 (1) #4 AWG AL THWN-2 NEU (1) #4 AWG AL THWN-2 EGC 1-1/4" EMT CONDUIT (DISTANCE: 100 FT) (CONDUIT BY CALSOLAR) 21 1615 1615 DC1 (N) PV AC DISCONNECT: 100A, 277/480V, 3Ø, 4W, NEMA 1, FUSIBLE, VISIBLE, J-RATED FUSE, UL LISTED Is.c. = 32,229A 80A FUSE AC2 AC3 21 21 1615 21 1615 21 21 1615 1716 (N) PV LOAD CENTER, 100A, 277/480V, 3Ø, 4W, 14KAIC, NEMA 3R, UL LISTED Is.c. = 9,193A (3) #2 AWG AL THWN-2 (1) #4 AWG AL THWN-2 NEU (1) #4 AWG AL THWN-2 EGC 1-1/4" EMT CONDUIT & 1" EMT CONDUIT FOR DATA CABLE (DISTANCE: 80 FT THROUGH STUB UP) (CONDUIT BY OTHERS) (3) #3/0 AWG CU THWN-2 (1) #4 AWG CU THWN-2 NEU (1) #6 AWG CU THWN-2 GEC 2-1/2" RMC CONDUIT (DISTANCE: 16.5 FT) (CONDUIT BY CALSOLAR) 1" EMT CONDUIT TO ELECTRICAL ROOM COMM CABLE CO M M C A B L E AC1 (3) #4 AWG AL THWN-2 (1) #4 AWG AL THWN-2 NEU (1) #4 AWG AL THWN-2 EGC 1-1/4" EMT CONDUIT (DISTANCE: 100 FT) (CONDUIT BY CALSOLAR) M G NGRID EXISTING WIRING MAIN SWITCHBOARD 'MSB', 2000A, 277/480V, 3Ø, 4W, 65KAIC (E) GROUNDING ELECTRODE SYSTEM 2000A 3P 65KAIC CT'S 2000A BUS 200A 3P PV SYSTEM BREAKER BY OTHERSON ROOF ELECTRICAL ROOM GFP ARC FLASH REDUCT UM MD P AC D LC INV IN V 4/30/2025 KG PV-5 Date Plotted: Drawn By Checked By SHEET NO. SHEET NAME SIGNATURE & SEAL Project Number 200 S. San Pedro St #500 Los Angeles, CA 90012, USA info@calsolarinc.com www.calsolarinc.com C-46 SOLAR LIC. #1004246 800-784-7612 No.Description Date 36 0 0 , S S U S A N S T , SA N T A A N A , CA 92 7 0 4 SO U T H C O A S T T E C H N O L O G Y C E N T E R (56 . 7 4 5 K W D C S T C / 50 . 0 0 0 K W A C C E C ) SH 1 REVISION 04/16/2025 SP E C S H E E T SAFETY PLACARD WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION CODE: PER NEC 706.15 (C)(4) NEC 690.13(B) ! WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION CODE: PER NEC 706.15 (C)(4) NEC 690.13(B) ! AC DISCONNECT MAIN SERVICE PANEL JUNCTION BOX PHOTOVOLTAIC POWER SOURCE CODE(S): PER NEC 690.31(D)(2) CONDUIT RACEWAYS SOLAR PV DC CIRCUIT CODE(S): PER NEC 690.31(D)(2) DC CONDUIT RACEWAYS WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL CODE: PER NEC 110.27(C) & OSHA 1910.145(F)(7) ! JUNCTION BOX WARNING RACEWAY IS ENERGIZED WHEN IN THE OPEN POSITION. DO NOT RELOCATE OR CUT ! CONDUIT, CABLES, PULL BOXES, J-BOX MAXIMUM DC VOLTAGE ON PV SYSTEM CODE: PER NEC 690.53 PHOTOVOLTAIC DC DISCONNECT JUNCTION BOX SOLAR INVERTER/DC DOSCO.INVERTER / DC DISCONNECT CODE: PER NEC 690.13(B) RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: 61A 480V CODE: PER NEC: 690.54 PHOTOVOLTAIC AC DISCONNECT AC DISCONNECT 1000 PHOTOVOLTAIC AC DISCONNECT AC DISCONNECT CODE: PER NEC 690.13(B) WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL CODE: PER NEC 110.27(C) & OSHA 1910.145(F)(7) ! MAIN SERVICE PANEL WARNING!DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM MAIN SERVICE PANEL PERFORMANCE METER CODE: PER NEC 690.59 & NEC 705.12(D)(3) AC DISCONNECT MAIN SERVICE PANEL CODE: PER NEC 690.56(C)(2) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM MAIN SERVICE PANEL CODE: PER NEC 690.15(B) & NEC 690.33(D)(2) DO NOT DISCONNECT UNDER LOAD WARNING PHOTOVOLTAIC SYSTEM COMBINER PANEL ! PV LOAD CENTER DO NOT ADD LOADS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. CODE: PER NEC 605.11.3.1(1) & NEC 690.56(C) MAIN SERVICE PANEL CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECT AS SHOWN METER MAIN SERVICE PANEL INVERTERS PV AC DISCONNECT W LAKE CENTER DR S S U S A N S T PV LOAD CENTER SIGNAGE NOTES: 1.ARTICLES 690 AND 705 MARKINGS SHOWN HEREON 2.ALL MARKINGS SHALL CONSIST OF THE FOLLOWING: A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING B.RED BACKGROUND COLOR WITH WHITE TEXT AND LINE WORK UON C.ARIAL FONT 3.ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. 4.SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT USING PERMANENT ADHESIVE. ARASH ZANDIEH 2025.07.13 21:45:00 REFE R E N C E S H E E T RE F E R E N C E S H E E T Date Plotted: Drawn By Checked By SHEET NO. SHEET NAME SIGNATURE & SEAL Project Number 200 S. San Pedro St #500 Los Angeles, CA 90012, USA info@calsolarinc.com www.calsolarinc.com C-46 SOLAR LIC. #1004246 800-784-7612 No.Description Date 47 7 9 T H A V E , S A N M A T E O , C A 9 4 4 0 2 , U S A 47 7 9 T H A V E KG 4/30/2025 23042/24008 PV-7.0 22 6 . 5 6 k W D C S T C / 1 6 0 . 0 k W A C C E C PG YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs CARUSO TURLEY SCOTT structural engineers STRUCTURAL ENGINEERING EXPERTS PARTNERS Sandra Herd, SE, PE, LEED AP Thomas Morris, SE, LEED AP Richard Dahlmann, SE, PE Troy Turley, SE, PE, LEED AP Brady Notbohm, SE, PE Craig Porter, SE, PE Ron Kuklish, SE, PE PROFESSIONAL REGISTRATION 50 States Washington D.C. U.S. Virgin Islands Puerto Rico 1215 W. Rio Salado Pkwy. Suite 200 Tempe, AZ 85281 T: (480) 774-1700 F: (480) 774-1701 Job No.25-0242-3336 Sheet No.Cover By BDW/TET Date 5/7/25 CLIENT: 1600 Osgood Street North Andover, MA 01845 PROJECT: South Coast Technology Center 3600 S Susan St. Santa Ana, CA 92704 GENERAL INFORMATION: BUILDING CODE: 2022 CBC, ASCE 7-16 With SEAOC PV1-2012 and PV2-2017 5/7/2025 TROY E.TURLEY HSA & ASSOCIATES, INC. CONSULTING STRUCTURAL ENGINEERS APPROVED BY DATE REVIEWED FOR USE ON SUBJECT JOB ONLY NOT RESPONSIBLE FOR: QUANTITIES, OMISSIONS OR DEVIATIONS FROM CONTRACT DOCUMENTS. CONTRACTOR TO VERIFY ALL DIMENSIONS ON JOBS. MAKE CORRECTION AS NOTED REJECTED REVISE AND RESUBMIT FOR INFORMATION ONLY 4 fady 5/8/2025 CARUSO TURLEY SCOTT structural engineers STRUCTURAL ENGINEERING EXPERTS PARTNERS Sandra Herd, SE, PE, LEED AP Thomas Morris, SE, LEED AP Richard Dahlmann, SE, PE Troy Turley, SE, PE, LEED AP Brady Notbohm, SE, PE Craig Porter, SE, PE Ron Kuklish, SE, PE PROFESSIONAL REGISTRATION 50 States Washington D.C. U.S. Virgin Islands Puerto Rico 1215 W. Rio Salado Pkwy. Suite 200 Tempe, AZ 85281 T: (480) 774-1700 F: (480) 774-1701 Date: May 7, 2025 Mr. Ryan Heil PanelClaw 1600 Osgood Street, Ste. 2023 North Andover, MA 01845 RE: Evaluation of PanelClaw system Project Name: South Coast Technology Center CTS Job No.: 25-0242-3336 Per the request of Ryan Heil at PanelClaw, CTS was asked to review the PanelClaw racking system with respect to the system’s ability to resist uplift and sliding caused by wind and seismic loads. Wind Evaluation: PanelClaw has provided CTS with wind tunnel testing performed by CPP, Inc. The system tested was the “clawFR 10 Degree” system. This system consists of photovoltaic panels installed at a 10 degree tilt onto support assemblies. The support assemblies consist of a support frame for the PV panels, wind deflectors and areas for additional mass/weight as required for the ballast loads. The wind tunnel testing was performed per Chapter 31 of ASCE 7-16. The parameters of the testing were a flat roof system in both Exposure B and C on a building with and without parapets. The testing has resulted in pressure and/or force coefficients that were applied to the velocity pressure qz in order to obtain the wind loads on the PV system. From the wind load results it is then possible to calculate the ballast loads required to resist the uplift and sliding forces. PanelClaw has provided CTS with the excel tool that was developed to obtain the uplift and sliding forces. CTS has reviewed this tool and the wind forces obtained to find that the amounts of ballast and mechanical attachments provided are within the values required. Furthermore, CTS agrees with the methodologies used to develop the uplift and sliding forces for the “clawFR 10 Degree” system per the wind tunnel testing results. Seismic Evaluation: CTS was asked to review the PanelClaw system to determine attachments required to resist seismic loading of the ballasted solar support system on the roof of the existing building. Following CBC Load Combination 16-16 and ASCE Section 2.4.5, the Dead Load value has been reduced by subtracting the vertical component of the seismic forces (0.6*D - 0.14Sds*D). The contribution of friction due to the component weight was not considered to resist lateral forces caused by seismic loads per ASCE Section 13.4. Utilizing this method, calculations have been provided for the number of mechanical attachments that are required to resist seismic forces that are applied to the system. CARUSO TURLEY SCOTT structural engineers STRUCTURAL ENGINEERING EXPERTS PARTNERS Sandra Herd, SE, PE, LEED AP Thomas Morris, SE, LEED AP Richard Dahlmann, SE, PE Troy Turley, SE, PE, LEED AP Brady Notbohm, SE, PE Craig Porter, SE, PE Ron Kuklish, SE, PE PROFESSIONAL REGISTRATION 50 States Washington D.C. U.S. Virgin Islands Puerto Rico 1215 W. Rio Salado Pkwy. Suite 200 Tempe, AZ 85281 T: (480) 774-1700 F: (480) 774-1701 Conclusion: Therefore, it has been determined that the system as provided by PanelClaw is sufficient to resist both wind and seismic loads at this project. Please contact CTS with any questions regarding this letter or attachments. Respectfully, Barrett Wise Troy Turley, SE, PE, LEED AP Structural Designer Partner 5/7/2024 TROY E.TURLEY Partner Name:Calsolar inc Project Name:South Coast Technology Center Project Location:3600 S Susan St, Santa Ana, CA 92704, USA Racking System:clawFRplus 10 Degree Structural Calculations for Roof-Mounted Solar Array Submittal Release: Rev 0 Engineering Seal 05/02/2025 APPROVED FOR CONSTRUCTION 5/7/2025 TROY E.TURLEY Not approved for construction by the City. Remove or clarify note. Typ all sheets Table of Contents Section:Page # 05/02/2025 APPROVED FOR CONSTRUCTION 2 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1.0 Project Information 4 1.1 General 4 1.2 Building Information 4 1.3 Structural Design Information 5 2.0 Snow Load 6 2.1 Snow Load Data 6 2.2 Snow Load Per Module 6 3.0 Wind Load 7 3.1 Wind Load Data 7 3.2 Roof / Array Zone Map 7 3.3 Wind Design Equations 7 4.0 Design Loads - Dead 8 4.1 Dead Load of the Arrays 8 5.0 Design Loads - Wind 9 5.1.1 Global Wind Uplift Summary Table 9 5.1.2 Global Wind Shear Summary Table 10 6.0 Design Loads - Downward 11 6.1 Downward Wind Load Calculation 11 6.2 Racking Dimensions for Point Loads 11 6.3 Point Load Summary 12 7.0 Design Loads - Seismic 13 7.1 Seismic Load Data 13 7.2 Seismic Design Equations 13 7.3 Lateral Seismic Force Check 14 7.4 Vertical Seismic Force Check 15 Appendix: A. Wind Tunnel Tests and Load Analysis for PANELCLAW ROOF MOUNT 10° TILT SOUTH-FACING, Peutz 05/02/2025 APPROVED FOR CONSTRUCTION 3 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1.0 Project Information: 1.1 General: Project Name:South Coast Technology Center Project Location:3600 S Susan St, Santa Ana, CA 92704, USA Racking System:clawFRplus 10 Degree Module:PHONO SOLAR PS585M8GFH-24/TNH Module Weight:70.55 lbs. Module Tilt:8.99 deg. Module Width:44.65 in. Module Length:89.69 in. Module Area:27.81 sq.ft. Ballast Block Weight:32.60 lbs. 1.2 Building Information: Roof Name Height (ft.)Parapet Height (ft.) Roof 1 48 4.0 Sub-Array Name Pitch (Deg)Membrane Material Coeff. of Friction (μ) 1.1 1 Asphalt SBS Adhered 0.64 1.2 1 Asphalt SBS Adhered 0.64 05/02/2025 APPROVED FOR CONSTRUCTION 4 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 1.0 Project Information (Cont.): 1.3 Structural Design Information: ASCE Code:ASCE 7-16 Building Code:CBC 2022 Risk Cat.:II Basic Wind Speed (V):95 mph Exposure Category:C Ground Snow Load (Pg):0 psf Is:1 Site Class:D Short Period Spectral Resp. (5%) (Ss):1.308 1s Spectral Response (5%) (S1):0.47 Ie:1 Ip:1 05/02/2025 APPROVED FOR CONSTRUCTION 5 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 2.0 Snow Load: Snow Calculations per ASCE 7-16, Chapter 7 2.1 Snow Load Data: Ground Snow Load (Pg)=0.00 psf (ASCE, Figure 7.2-1) Exposure Factor (Ce)=1 (ASCE, Table 7.3-1) Thermal Factor (Ct)=1.2 (ASCE, Table 7.3-2) Importance Factor (Is)=1 (ASCE, Table 1.5-2) Flat Roof Snow Load (Pf) =0.7*Pg*Ce*Ct*Is=0.00 psf (ASCE 7.3-1) Min Snow Load for Low Slope Roof =Pg*Is =0.00 psf (ASCE 7.3.4) Snow Load on Array (SLA) =0.00 psf SLA Fig. 2.1 - Uniform Roof Snow Load on Array 2.2 Snow Load Per Module: Snow Load per Module (SLM) =Module Projected Area SLA Where; Module Projected Area (Amp) = Module Area * Cos(Module Tilt) Where; Module Area =27.81 sq.ft. Module Tilt =8.99 deg. Amp =27.46 sq.ft. SLM =   Amp     SLA   = 0.00     lbs. 05/02/2025 APPROVED FOR CONSTRUCTION 6 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 3.0 Wind Load: Wind Analysis per ASCE 7-16- Wind Tunnel Procedure, Chapter 31 3.1 Wind Load Data: Basic Wind Speed (Vult) =95 mph (ASCE, Fig. 26.5-1) Exposure Category:C (ASCE, Sec. 26.7.3) Topographic Factor (Kzt) =1 (ASCE, Fig. 26.8-1) Directionality Factor (Kd) =0.85 (ASCE, Table 26.6-1) Exposure Coefficient (Kz) =1.08 (ASCE, Table 26.10-1) Ground Elevation Factor (Ke) =1.00 (ASCE, Table 26.9-1) Velocity Pressure (qz) =0.00256*Kz*Kzt*Kd*Ke*V^2 =21.27 psf (ASCE, Eqn. 26.10-1) 3.2 Roof / Array Zone Map: Figure 3-1. South corner zones – 90-180° wind directions Figure 3-2. North corner zones – 0- 90° wind direction Roof Zone Map Dimensions per PEUTZ Wind Tunnel Study Height (ft.)LB* (ft.)Velocity Pressure (qz) (psf) 48 48.00 21.27 * LB = Characteristic length per wind tunnel study 3.3 Wind Design Equations: FL = qz Aref CL FL = sum of lift on panel and deflector. FD - L Companion = qz Aref CD - L FD - L = Worst-case drag and uplift combination at corresponding coefficient of friction. Where qz = Velocity Pressure (Ref. Section 3.1, Wind Load) Aref = Module Area (Ref. Section 1.1, General) CL, CD-L = Vary and related to wind zone map (Proprietary Wind Tunnel Coefficients) 05/02/2025 APPROVED FOR CONSTRUCTION 7 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 4.0 Design Loads - Dead: There are two categories of dead load used to perform the structural analysis of the PanelClaw racking system; Dead Load of the Array (DLA) and Dead Load of the Components (DLC). DLA is defined as the weight of the entire array including all of the system components and total ballast used on the array. DLC is defined as the weight of the modules and the racking components within an array. The DLC does not include the ballast used to resist loads on this array. 4.1 Dead Load of the Arrays: Array Information Results Sub- Array Name Number of Modules DLC (lbs.) DLA (lbs.) DLC (lbs.)/module Sub- Array Area (ft.^2) Sub-Array Roof Pressure (psf) (DLC) (psf) Sub-Array Roof Pressure (psf) (DLA) (psf) Max Allowable Pressure on Roof (psf) Acceptable? 1.1 49 4,416 11,686 90 1,689 2.61 6.92 20.00 Yes 1.2 48 4,303 9,096 90 1,656 2.60 5.49 20.00 Yes Total:  97 8,719 lbs.20,781 lbs. *Racking component weight range between 13 to 15 pounds per module Table 4.1 - Array Dead Loads and Roof Pressures 05/02/2025 APPROVED FOR CONSTRUCTION 8 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 5.0 Design Loads - Wind: 5.1.1 Global Wind Uplift Summary Table: The necessity to add mechanical attachments can arise for several reasons. Building code requirements, roof load limits and array shape all may come into play when determining their need. The table below provides the mechanical attachment requirements for each sub-array within this project.  Applied Load Resisting Load Code Check Sub- Array Name FL = Total Wind Uplift (lbs.) DL = Total Dead Load (lbs.) Maximum Allowable Mechanical Attachment Strength (lbs.) Total MA Capacity (lbs.) Calculated Factor of Safety* Check 1.1 17,953 11,686 525 6,328 1.67 OK 1.2 18,411 9,096 525 9,838 1.71 OK Total:36,364 lbs.20,781 lbs. 16,166 lbs. Table 5.1 Summary of Mechanical Attachment Requirements * Back calculated factor of safety provided to determine factor of safety applied to dead load in lieu of 0.6 in ASCE 7-16 equation 7, BACK CALCULATED FACTOR OF SAFETY = (DEAD LOAD+MECHANICAL ATTACHMENT)/(0.6)WIND LOAD 05/02/2025 APPROVED FOR CONSTRUCTION 9 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 5.0 Design Loads - Wind (Cont.): 5.1.2 Global Wind Shear Summary Table: Mechanical attachments may be required for several reasons including building code, roof load limits and array shape. The table below provides the mechanical attachment requirements for each sub-array within this project.  Applied Load Resisting Load Code Check Sub- Array Name FD-L = Wind Drag-Lift (lbs.) DL = Total Dead Load (lbs.) Maximum Allowable Mechanical Attachment Strength (lbs.) Total MA Capacity (lbs.) Check Calculated Factor of Safety* Check 1.1 8,790 11,686 650 11,050 4.31 OK 1.2 8,625 9,096 650 13,000 4.27 OK Total:17,415 lbs.20,781  24,050 lbs. Table 5.2 Summary of Mechanical Attachment Requirements * Back calculated factor of safety provided to determine factor of safety applied to dead load in lieu of 0.6 in ASCE 7-16 equation 7, BACK CALCULATED FACTOR OF SAFETY = (DEAD LOAD+MECHANICAL ATTACHMENT)/((.6)WIND DRAG-LIFT) 05/02/2025 APPROVED FOR CONSTRUCTION 10 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 6.0 Design Loads - Downward: 6.1 Downward Wind Load Calculation: WLin = qz * Am * GCP * cos θ Where: qz =21.27 psf (Ref. Section 3.1, Wind Load Data) Am =27.81 sq.ft.(Single Module Area)(Ref. Section 1.1, General Project Information) θ =8.99 deg.(Ref. Section 1.1, General Project Information) GCP =1.13 (Inward)(Proprietary Wind Tunnel Data) GCP =0.30 (Inward with snow)(ASCE, Fig. 30.3-5A) WLin(no snow) = 660 lbs./module WLin(with snow) = 175 lbs./module Contact Base by Location:                                                        Contact Pad by Information: 1 =South Distance Between C.C. outer Pads =12.5 in. 2 =Interior Typical Pad Area =9 sq.in. 3 =2nd from North 4 =North 6.2 Racking Dimensions for Point Loads: Inter-Module Support spacing (S) = 49.06 in. Inter-Column Support Spacing (L) = 41.34 in. Fig. 6.1 Typical Array Plan View (Section A-A) on Next Page 05/02/2025 APPROVED FOR CONSTRUCTION 11 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 6.0 Design Loads - Downward (Cont.): 6.2 Racking Dimensions for Point Loads (Cont.): Fig. 6.2 Section A-A 6.3 Point Load Summary:Notes: DLsys = 90 lbs./module -Base 2 repeat for larger width arrays. Total DL = (Varies on location and ballast quantity) SLm = 0 lbs./module WLin (no snow) = 660 lbs./module WLin (with snow) = 175 lbs./module Max Total Load Per Base (lbs.) load combinations (ASD) Location Base DL + Snow DL + 0.6Wlin DL + 0.75SLm + 0.75(0.6WLin) South 1 63 162 83 Interior 2 173 371 213 2nd From North 3 140 338 179 North 4 119 218 139 Table 6.1-A Max Total Load per Base (lbs.) Max Contact Pressure Table Per Base (psi) load combinations (ASD)# of Pads Location Base DL + Snow DL + 0.6Wlin DL + 0.75SLm + 0.75(0.6WLin) South 1 3 9 5 Interior 2 9 20 12 2nd From North 3 8 18 10 2 North 4 6 12 8 South 1 2 4 2 Interior 2 5 10 6 2nd From North 3 4 9 5 4 North 4 3 6 4 Table 6.1-B Max Point Load Summary (psi) 05/02/2025 APPROVED FOR CONSTRUCTION 12 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 7.0 Design Loads - Seismic: Seismic Calculations per ASCE 7-16, Chapter 11 - Seismic Design Criteria Chapter 13 - Requirements for Nonstructural Components 7.1 Seismic Load Data: Site Class :D (Ref. Project Information) Seismic Design Category :D (ASCE, Tables 11.6-1 and 11.6-2) Short Period Spectral Resp. (5%) (Ss) :1.308 (Ref. Project Information) 1s Spectral Response (5%) (S1) :0.47 (Ref. Project Information) Bldg. Seismic Imp. Factor (Ie) =1 (ASCE, Table 1.5-2) Adj. MCE Spec. Resp. (Short) (Sms) =Fa*Ss =1.570 (ASCE, Eqn. 11.4-1) Adj. MCE Spec. Resp. (1 sec.) (Sm1) =Fv*S1 =0.860 (ASCE, Eqn. 11.4-2) Short Period Spectral Response (Sds) =2/3(Sms) =1.046 (ASCE, Eqn. 11.4-3) One Second Spectral Response (Sd1) =2/3(Sm1) =0.573 (ASCE, Eqn. 11.4-2) Component Seismic Imp. Factor (Ip) =1 (ASCE, Sec. 13.1.3) Repsonse Modification Factor (Rp) =2.5 (ASCE, Table 13.6-1) Amplification Factor (ap) =1 (ASCE, Table 13.6-1) 7.2 Seismic Design Equations: Lateral Force (Fp) =(ASCE, Eqn. 13.3-1) Lateral Force (FPLmin) =(ASCE, Eqn. 13.3-3) Lateral Force (FPLmax) =(ASCE, Eqn. 13.3-2) Vertical Force (Fpv)) =(ASCE, Eqn. 12.4-4) Lateral Resisting Force (FRL)* =0 (Factored Load, ASD) Vertical Resisting Force (FRV) =(Factored Load, ASD) * Frictional resistance due to the components weight may not be used to resist lateral forces caused by seismic loads. 05/02/2025 APPROVED FOR CONSTRUCTION 13 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 7.0 Design Loads - Seismic (Cont.): 7.3 Lateral Seismic Force Check: The necessity to add mechanical attachments can arise for several reasons. Building code requirements, roof load limits and array shape all may come into play when determining their need. The table below provides the mechanical attachment requirements for each sub-array within this project. Nomenclature: WP = Sub-Array Weight FPL = Lateral Seismic Force FRL = Lateral Seismic Resisting Force Array Information Lateral Force Verification Results Sub- Array Name WP (lbs.) FPL (lbs.) FRL (lbs.) 0.7 FPL - FRL (lbs.) MA's Required Total MA Capacity (lbs.) MA's Provided Acceptable 1.1 11,686 5,869 0 4,109 7 11,050 17 Yes 1.2 9,096 4,568 0 3,198 5 13,000 20 Yes Totals:20,781 lbs 10,438 lbs.0 lbs.7,307 lbs.12 24,050 37 Table 7.1 - Summary of Mechanical Attachment Requirements * MA's Required = 0.7 FPL-FRL/MA strength 05/02/2025 APPROVED FOR CONSTRUCTION 14 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com 7.0 Design Loads - Seismic (Cont.): 7.4 Vertical Seismic Force Check: Mechanical attachments may be required for several reasons including building code, roof load limits and array shape. The table below provides the mechanical attachment requirements for each sub-array within this project. Nomenclature: WP = Sub-Array Weight FPV = Vertical Seismic Force FRV = Vertical Seismic Resisting Force Array Information Vertical Force Verification Results Sub- Array Name WP (lbs.) FPV (lbs.) FRV (lbs.) 0.7 FPL - FRL (lbs.) MA's Required Total MA Capacity (lbs.) Total MA's Provided Acceptable 1.1 11,686 2,446 7,011 -5,300 0 6,328 17 Yes 1.2 9,096 1,904 5,457 -4,125 0 9,838 20 Yes Total:20,781 lbs.4,349 lbs.12,469 lbs.-9,424 lbs.0 16,166 37 Table 7.2 - Summary of Mechanical Attachment Requirements * MA's Required = 0.7 FPV - FRV/MA strength 05/02/2025 APPROVED FOR CONSTRUCTION 15 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com Appendix A Appendix A 16 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com Appendix A 17 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com Appendix A 18 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com Appendix A 19 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com Appendix A 20 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com Appendix A 21 PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 (978) 688.4900 - www.panelclaw.com AHZ Consulting Engineers, Inc. 111 Rodeo Irvine, CA 92602 (949) 466-1544 (901) 692-0431 07/13/2025 CalSolar, Inc. 200 South San Pedro St Suite #500 Los Angeles, CA 90012 REFERENCE: 3600, S SUSAN ST, SANTA ANA, CA 92704 To Whom It May Concern: Per your request, we have reviewed the existing roof framing at the above referenced site. The purpose of our review was to determine the adequacy of the existing structure to support the proposed installation of solar panels on the roof as shown on the panel layout plan. Based upon our review, we conclude that the existing structure is adequate to support the proposed solar panel installation with the given geometry and weight restriction outline in this report. The mechanical attachment for the PV ballast system is also designed in this calculation and can be used if applicable. The PV ballast system including requirements for blocks and mechanical attachments to resist the wind and seismic forces (uplift, drag, lateral) to be designed by others. The design of the PV ballast system is out of scope of this calculation. If you have any questions, don't hesitate to contact. Sincerely, Arash Zandieh, Ph.D., P.E. a.zandieh@ahzengineers.com | 901-692-0431 AHZ Consulting Engineers, Inc. ARASH ZANDIEH 2025.07.13 21:45:00 AHZ Consulting Engineers, Inc. 111 Rodeo Irvine, CA 92602 (949) 466-1544 Date: 07/13/2025 Job Code: 25035 South Coast Tech Page 2 of 20 Design Codes and Guidelines: 1. 2022 California Building Code. 2. ASCE (2016). “Minimum Design Loads for Buildings and Other Structures. ASCE/SEI Standard 7-16.” Design parameters: Risk Category: II Design wind speed: 95 mph Wind exposure category: C Ground snow load: 0 psf Structure Height: 48 Ft Live Load (Psf): 20 (Not Applied at Panels) Seismic Design Category: D Seismic Importance Factor: 1.0 SS: 1.308g, S1: 0.47g Soil Site Class: D-Default SDS: 1.046g, SD1: 0.573g Solar Module: PHONO SOLAR 585W (PS585M8GFH-24/TNH) Length 7.47 ft Width 3.72 ft Weight 70.55 lbs Weight of PV panels: WPV= 2.54 psf AHZ Consulting Engineers, Inc. 111 Rodeo Irvine, CA 92602 (949) 466-1544 Date: 07/13/2025 Job Code: 25035 South Coast Tech Page 3 of 20 Roof Check Methodology The increased weight due to the ballast installation is reported in the table below. A maximum uniform load of 6.21 psf is conservatively assumed for the ballast system and the existing roof structure is evaluated. Ballast weight is evenly distributed on the roof members. The following calculations show the increased load due to ballast installation is less than 5% of gravity design loads and is less than 10% of the seismic design weight for the lateral load calculation. Therefore, no further calculation is required, and the existing roof structure has adequate capacity to resist the ballast-installed load. PV load (psf) = 6.21 Area of solar panels (sqft) = 3347 Total weight (lbs) = 20782 Existing roof loads Gravity Check: Dead (psf)= 10 Live (psf) = 20 Snow (psf) = 0 Load pre-PV D (psf) = 10 D + L (psf) = 30 D + S (psf) = 10 D + 0.75 L + 0.75 S (psf) = 25 Governing load (psf) = 30 Load post-PV D (psf) = 16.21 D + L (psf) = 26.21 D + S (psf) = 16.21 Governing load (psf) = 26.21 Gravity load increase Load_postPV / Load_prePV = 0.87 OK AHZ Consulting Engineers, Inc. 111 Rodeo Irvine, CA 92602 (949) 466-1544 Date: 07/13/2025 Job Code: 25035 South Coast Tech Page 4 of 20 Seismic Check: Wall weight (psf) = 17 Tributary wall area (sqft) = 12600 Total wall weight (lbs) = 214200 Roof weight (psf) = 10 Roof area (ft) = 98000 Roof weight (lbs) = 980000 Total roof seismic weight (lbs) = 1194200 Weight Increase: (Existing W + Additional W)/ (Existing W) = 1.02 OK AHZ Consulting Engineers, Inc. 111 Rodeo Irvine, CA 92602 (949) 466-1544 Date: 07/13/2025 Job Code: 25035 South Coast Tech Page 5 of 20 Attachment Load: The ballast report is provided in Appendix 1. According to the report, the maximum uplift load (525 lbs) and lateral load (650 lbs) occur at the attachment points. Mechanical Attachment Check: The attachment is U-Anchor® U2600-APP. The datasheet for U-Anchor® U2600-APP is provided in Appendix 2. As shown in Appendix 2, the tension and shear ultimate capacity are: • Ultimate Load - Shear: 4339 lbs • Ultimate Load - Tension: 2713 lbs The U-Anchor® U2600-APP is used with 4 fasteners. The ICC ESR report for U-Anchor is provided in Appendix 3. As shown in Appendix 3, the allowable tension and shear for U-Anchor are: • Allowable Shear: 1446 lbs > 650 lbs OK • Allowable Tension: 813 lbs > 525 lbs OK For deck mount installation: For (4) UltraFast #12 screws embedded into 1/2-inch plywood (Appendix 4): - Allowable Uplift = 4 x 326 = 1304 lbs > 525 lbs OK AHZ Consulting Engineers, Inc. 111 Rodeo Irvine, CA 92602 (949) 466-1544 Date: 07/13/2025 Job Code: 25035 South Coast Tech Page 6 of 20 Appendix 1 Ballast Report AHZ Consulting Engineers, Inc. 111 Rodeo Irvine, CA 92602 (949) 466-1544 Date: 07/13/2025 Job Code: 25035 South Coast Tech Page 7 of 20 AHZ Consulting Engineers, Inc. 111 Rodeo Irvine, CA 92602 (949) 466-1544 Date: 07/13/2025 Job Code: 25035 South Coast Tech Page 8 of 20 AHZ Consulting Engineers, Inc. 111 Rodeo Irvine, CA 92602 (949) 466-1544 Date: 07/13/2025 Job Code: 25035 South Coast Tech Page 9 of 20 AHZ Consulting Engineers, Inc. 111 Rodeo Irvine, CA 92602 (949) 466-1544 Date: 07/13/2025 Job Code: 25035 South Coast Tech Page 10 of 20 Appendix 2 U-Anchor® U2600-APP Data Sheet AHZ Consulting Engineers, Inc. 111 Rodeo Irvine, CA 92602 (949) 466-1544 Date: 07/13/2025 Job Code: 25035 South Coast Tech Page 11 of 20 AHZ Consulting Engineers, Inc. 111 Rodeo Irvine, CA 92602 (949) 466-1544 Date: 07/13/2025 Job Code: 25035 South Coast Tech Page 12 of 20 Appendix 3 U-Anchor ICC-ES Report AHZ Consulting Engineers, Inc. 111 Rodeo Irvine, CA 92602 (949) 466-1544 Date: 07/13/2025 Job Code: 25035 South Coast Tech Page 13 of 20 AHZ Consulting Engineers, Inc. 111 Rodeo Irvine, CA 92602 (949) 466-1544 Date: 07/13/2025 Job Code: 25035 South Coast Tech Page 14 of 20 AHZ Consulting Engineers, Inc. 111 Rodeo Irvine, CA 92602 (949) 466-1544 Date: 07/13/2025 Job Code: 25035 South Coast Tech Page 15 of 20 AHZ Consulting Engineers, Inc. 111 Rodeo Irvine, CA 92602 (949) 466-1544 Date: 07/13/2025 Job Code: 25035 South Coast Tech Page 16 of 20 AHZ Consulting Engineers, Inc. 111 Rodeo Irvine, CA 92602 (949) 466-1544 Date: 07/13/2025 Job Code: 25035 South Coast Tech Page 17 of 20 AHZ Consulting Engineers, Inc. 111 Rodeo Irvine, CA 92602 (949) 466-1544 Date: 07/13/2025 Job Code: 25035 South Coast Tech Page 18 of 20 Appendix 4 UltraFast #12 Data Sheet AHZ Consulting Engineers, Inc. 111 Rodeo Irvine, CA 92602 (949) 466-1544 Date: 07/13/2025 Job Code: 25035 South Coast Tech Page 19 of 20 AHZ Consulting Engineers, Inc. 111 Rodeo Irvine, CA 92602 (949) 466-1544 Date: 07/13/2025 Job Code: 25035 South Coast Tech Page 20 of 20