ELECTRICAL N❑TES1
<br />CITY OF SANTA ANA
<br />v_o
<br />DOOR SCHEDULE:
<br />yl
<br />1. BOTTOM OF CEILING IS AT 8' ABOVE FINISHED FLOOR AT ALL AREAS
<br />WITHIN THE HOUSE.
<br />2, COUNTERTOPS IN THE KITCHEN, DINING AREA AND SIMILAR AREAS
<br />REQUIRE A RECEPTACLE BE PR❑VIDED FOR EACH COUNTER SPACE
<br />WIDER THAN 12' S❑ THAT NO P❑INT IS MORE THAN 24' FROM AN
<br />OUTLET. ALL OUTLETS IN KITCHEN SERVING COUNTERTOP SURFACES
<br />INCLUDING ISLAND SHALL BE GFI.
<br />3. ALL INSTALLED LUMINAIRES MUST BE HIGH EFFICACY IN ACCORDANCE
<br />WITH TABLE 150.0-A.
<br />4. IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT
<br />LEAST ONE LUMINAIRE IN EACH OF THESE SPACES MUST BE
<br />CONTROLLED BY A VACANCY SENSOR.
<br />5, DIMMERS OR VACANCY SENSORS MUST CONTROL ALL LUMINAIRES
<br />REQUIRED TO HAVE LIGHT SOURCES C❑MPLIANT WITH REFERENCE
<br />J❑INT APPENDIX JA8, EXCEPT LUMINAIRES IN CLOSETS LESS THAN 70
<br />SQUARE FEET AND LUMINAIRES IN HALLWAYS PER 150,0(k)2K.
<br />6. OUTDOOR LIGHTING PERMANENTLY MOUNTED TO A RESIDENTIAL
<br />BUILDING, OR TO OTHER BUILDINGS ON THE SAME LOT, MUST MEET
<br />THE REQUIREMENT IN ITEM § 150.0(K)3AI (ON AND OFF SWITCH) AND
<br />THE REQUIREMENTS IN EITHER ITEM § 150,0(K)3AII (PHOTOCELL AND
<br />M❑TI❑N SENSOR) OR ITEM § 150,0(K)3AIII (PHOTO CONTROL AND
<br />AUT❑MATIC TIME SWITCH CONTROL, ASTR❑N❑MICAL TIME CLOCK, OR
<br />EMCS).
<br />7. UNDERCABINET LIGHTING MUST BE SWITCHED SEPARATELY FROM
<br />OTHER LIGHTING SYSTEMS,
<br />8. OCCUPANCY SENSORS MUST HAVE NO MANUAL ❑VERRIDE, 30-MINUTE
<br />MAXIMUM TIMER AND BE MICR❑WAVE/ULTRAS❑NIC OR PASSIVE
<br />INFRARED TYPE.
<br />9. HIGH EFFICACY LUMINARIES MUST BE PIN BASED.
<br />11. A GFI 120 VOLT RECEPTACLE SHALL BE PROVIDED AT FRONT AND BACK OF
<br />THE DWELLING UNIT.
<br />12. WALLS 2' WIDE OR GREATER SHALL HAVE AN OUTLET; OUTLETS SHALL BE
<br />SPACED NO MORE THAN 12' APART AND A MAXIMUM OF 6' FROM END OF
<br />WALLS OR OPENING.
<br />13. HALLWAYS OVER 10' IN LENGTH SHALL BE PROVIDED WITH ELECTRICAL
<br />OUTLETS.
<br />14. ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLT, SINGLE PHASE, 15 AND 20
<br />AMPERE OUTLETS INSTALLED IN DWELLING UNITS SHALL BE PROTECTED BY AN
<br />ARC -FAULT CIRCUIT INTERRUPTERS. THIS REQUIREMENT IS FOR ENTIRE
<br />CIRCUIT, NOT JUST THE OUTLETS.
<br />15. BRANCH CIRCUIT SERVING THE GARAGE RECEPTACLES SHALL NOT SERVE
<br />OUTLETS OUTSIDE OF THE GARAGE.
<br />16. ALL OUTDOOR LIGHTING SHALL BE CONTROLLED BY A MANUAL ON AND OFF
<br />SWITCH THAT DOES NOT OVERRIDE TO ON AND ONE OF THE FOLLOWING:
<br />CONTROLLED BY PHOTOCELL AND MOTION SENSOR, PHOTO CONTROL AND
<br />AUTOMATIC SWITCH CONTROL, ASTRONOMICAL TIME CLOCK, OR ENERGY
<br />MANAGEMENT CONTROL SYSTEM.
<br />17. ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS (INCLUDING
<br />CONTROLS FOR HEATING, VENTILATION AND AIR CONDITIONING) INTENDED TO
<br />BE USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48" MEASURED
<br />FROM THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15" MEASURED
<br />FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISHED FLOOR.
<br />PLUMBING PIPE SPECIFICATION
<br />APPLICATION
<br />UNDER GROUND
<br />ABOVE GROUND
<br />WATER INSIDE THE BUILDING
<br />PRE -INSULATED AQUAPEX
<br />PEX PIPE OR COPPER "L"
<br />WATER OUTSIDE THE BUILDING
<br />COPPER "K"
<br />COPPER "L"
<br />WATER PIPES CONNECTION
<br />TO THE WATER HEATER
<br />N/A
<br />COPPER "L"
<br />N❑TES1
<br />1. ALL PIPES AND FITTINGS SHALL COMPLY WITH MATERIAL SPECIFICATI❑N
<br />AS LISTED IN TABLE 604.1 OF THE PLUMBING CODE.
<br />2. ALL PIPE AND FITTING TO BE PRODUCED BY A SINGLE MANUFACTURER
<br />AND TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S
<br />REC❑MMENDATI❑NS AND PLUBMING CODE.
<br />3. HOT WATER PIPING SHALL BE INULATED; EXCEPT AT1
<br />A) PIPING THAT PENETRATES FRAMING MEMBERS FOR DISTANCE OF THE
<br />FRAMING PENETRATI❑N,
<br />B) PIPING BETWEEN THE FIXTURE CONTROL VALVE OR SUPPLY STOP
<br />AND THE FIXTURE OR APPLIANCE.
<br />NOTE: ALL KITCHEN
<br />COUNTER SHALL HAS
<br />COMBINATION AFCl/C
<br />RECEPTACLES
<br />fr\ rn rr'Mirni
<br />�r �(N HOUSE 1ST FLOOR
<br />�O 1 /4 = 12-Opp
<br />NO.
<br />SIZE (W'xH')
<br />REMARKS
<br />U-FACTOR
<br />SHGC
<br />0
<br />3'-O"x6'-8"
<br />EXTERIOR SOLID
<br />CORE DOOR. OPENABLE FROM INSIDE
<br />0.2
<br />-
<br />WITHOUT USE OF
<br />KEY OR SPECIAL D 0 F O T
<br />-
<br />2'-6"x6'-8"
<br />HOLLOW CORE D
<br />OR ftpp
<br />HOLLOW COR
<br />1 Q
<br />3
<br />2'-4"x6'-8"
<br />OPENING AT BO
<br />OM
<br />WINDOW SCHEDULE:
<br />NO.
<br />SIZE (W'xH')
<br />REMARKS
<br />U-FACTOR
<br />SHGC
<br />O
<br />4'x4'
<br />VINYL DUAL GLA
<br />EQ, SOW "E" TY PI,
<br />0.30
<br />0.23
<br />SLIDING
<br />VINYL DUAL GLA
<br />ED, LOW "E" TYPE,
<br />0
<br />2'x3'
<br />SINGLE HUNG, OESMtCiEMPERED
<br />GLASS
<br />0.30
<br />0.23
<br />0
<br />3,X3,
<br />VINYL DUAL GLA
<br />ED, LOW "E" TYPE,
<br />0.30
<br />0.23
<br />SLIDING
<br />0
<br />5'x4'
<br />VINYL DUAL GLA
<br />0.30
<br />0.23
<br />SLIDING W TEMPERED GLASS
<br />DOOR AND WINDOW SCHEDULE NOTES:
<br />1. ALL GLAZING TO BE DOUBLE GLAZED AND TO HAVE NON-METAL FRAMES.
<br />2. ALL WINDOWS BY "CRYSTAL PACIFIC WINDOWS" OR EQUAL.
<br />3. WINDOWS 1 IS EMERGENCY ESCAPE AND RESCUE WINDOWS; THE FINISHED
<br />SILL HEIGHT SHALL NOT BE MORE THAN 44" ABOVE THE FINISH FLOOR.
<br />4. THE NFRC TEMPORARY LABEL DISPLAYED ON WINDOWS MUST REMAIN
<br />ON THE UNIT UNTIL FINAL INSPECTION HAS BEEN COMPLETED.
<br />5. SEE DOOR AND WINDOW FLASHING DETAILS SHOWN ON SHEET A4.
<br />FLOOR PLAN LEGEND AND KEY NOTES:
<br />0 EXISTING WALL
<br />® NEW WALL
<br />24"00" ATTIC ACCESS
<br />❑1 DOOR THRESHOLD & LANDING, SEE DETAILS 5/A3.
<br />ELECTRICAL LEGEND AND NOTES:
<br />SD HARD WIRE WITH BATTERY BACKUP AND INTERCONNECTED
<br />SMOKE ALARM PER R314 AND UL217 COMPLIANCE
<br />© HARD WIRE WITH BATTERY BACKUP AND INTERCONNECTED CARBON
<br />MONOXIDE DETECTOR PER R315 AND UL2034/2075 COMPLIANCE
<br />RH 4" OR 6" RECESSED HIGH -EFFICACY LIGHT (LED LIGHTING, CERTIFIED TO THE
<br />ENERGY COMMISSION)
<br />EXTERIOR WALL MOUNTED HIGH -EFFICACY LUMINAIRE
<br />TV CONNECTIONS WITH ELECTRICAL RECEPTACLE, ETHERNET
<br />PORTS AND COAXIAL CABLES; COORDINATE W/ OWNER FOR
<br />MOUNTING HEIGHT.
<br />ELECTRICAL SWITCH
<br />°$ DIMMER ELECTRICAL SWITCH
<br />V$ ELECTRICAL SWITCH CONTROLLED BY VACANCY SENSOR
<br />P$ ELECTRICAL SWITCH WITH PHOTOCONTROL/MOTION SENSOR
<br />COMBINATION. SHALL BE HIGH EFFICACY LUMINARIES OR
<br />BE CONTROLLED BY A PHOTOCONTROL/MOTION SENSOR
<br />COMBINATION WITH OVERRIDE.
<br />DUPLEX RECEPTACLE, TEMPER RESISTANCE W/ ARC FAULT
<br />CIRCUIT INTERRUPTER PROTECTION
<br />GFI DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPTER. ALL
<br />KITCHEN COUNTER RECEPTACLES SHALL BE COMBINATION AFCl/GFCI
<br />�wP WATER PROOF DUPLEX RECEPTACLE WITH GROUND
<br />FAULT INTERRUPTER CIRCUIT
<br />DELTA BREEZ EXHAUST FAN, MODEL VFB25ACH: 80 CFM INTERMITTENT, 4"
<br />DUCT AND MAX. OF 20 LF, 0.3 SONE. W/ HUMIDITY SENSOR CONTROL
<br />10 20 AMP DEDICATED CIRCUIT IN BATHROOMS, TYP
<br />TANKLESS WATER HEATER: 0.95 UEF, 200000 BTU/HR; ALSO PROVIDE
<br />WEATHER-PROOF GFCI RECEPTACLE WITHIN 3' OF WATER HEATER
<br />(�3 MINI SPLIT A/C -HEAT PUMP, SEE CF1R FORMS
<br />® CARRIER GAS FURNACE OR SIMILAR: WITH AFUE=87% MIN. SEE DETAIL
<br />2/A1 FOR CLEARANCE, ACCESS, SUPPORT LIGHTING AND RECEPTACLE
<br />(�5 NEW 100 AMP SUBPANEL CONNECTING FROM MAIN DUAL 100 AMP
<br />SERVICE PANEL.
<br />© LAUNDRY CIRCUIT. SEPARTE CIRCUIT IS REQUIRED FOR LAUNDRY EQUIPMENT.
<br />(�7 NEW STOVE HOOD VENT AS IAQ: BROAN NUTONE MANTRA AVSF136 SERIES:
<br />375 CFM & 98.1% EFFICIENCY ® 1.5 SONES, 7" DUCT TO EXTERIOR AS PER
<br />MANUFACTURER OR EQUAL W/ 280 CFM MINIMUM & 3 SONE. ADD LABELING
<br />WITH FOLLOWING TEXT "THIS SWITCH CONTROLS THE INDOOR AIR QUALITY
<br />VENTILATION FOR THE HOME. LEAVE IT ON UNLESS THE OUTDOOR AIR
<br />QUALITY IS VERY POOR."
<br />® HOOD & STOVE GFI RECEPTACLE AND DEDICATED 240V STOVE RECEPTACLE
<br />@9 REFRIGERATOR RECEPTACLE & WATER VALVE OUTLET
<br />10 DISH WASHER & GARBAGE DISPOSER GFI RECEP. W/ SWITCH
<br />11 WHOLE HOUSE FAN: INSTALL "QUIETCOOL" MODEL QC ES-2250 WITH
<br />= 2492 CFM; OR SIMILAR W/ AIRFLOW RATE = 2492 CFM MIN.
<br />12 IAQ VENTILATION WITH "NUTONE" MODEL ZN80ML
<br />CONTINUEOUSLY VENTED, AIRFLOW RATE = 80 CFM, 15 LF MAX
<br />4"0 DUCT TO OUTSIDE, 0.3 SONE; OR SIMILAR WITH MIN 80 CFM
<br />& 1 SONE. PROVIDE LABELING ON SWITCH CONTROLS: "SWITCH
<br />FOR THE INDOOR AIR QUALITY VENTILATION FOR THE HOME.
<br />LEAVE SWITCH IN THE 'ON' POSITION AT ALL TIMES UNLESS THE
<br />OUTDOOR AIR QUALITY IS VERY POOR."
<br />/o QROFKSS
<br />co i
<br />O C64806 crn
<br />EXP 6/30/2025
<br />lF OF CAL\F��
<br />Q
<br />0
<br />w
<br />C7
<br />z
<br />N
<br />Q
<br />W
<br />�
<br />C7
<br />U
<br />�OCZ
<br />��O
<br />Q
<br />J
<br />CV 0
<br />Z
<br />,�
<br />O
<br />Ova
<br />LL_
<br />w
<br />,.LJOOzCL_
<br />=
<br />co
<br />CO
<br />Q O
<br />-t
<br />(J-) Cz
<br />I+i
<br />Zw
<br />o
<br />q
<br />Wz
<br />�
<br />�o
<br />w
<br />O
<br />�
<br />H
<br />H
<br />w
<br />w
<br />r�
<br />DRAWN BY:
<br />F.L.
<br />CHECK'D BY:
<br />F.L.
<br />SCALE:
<br />AS NOTED
<br />JOB NO.:
<br />PCN #:
<br />SHEET
<br />r N UTIL
<br />�O 1 /4 = 1 - 0
<br />TY P LAN -1ST FLOOR