HomeMy WebLinkAboutHISTORIC-606 S Van Ness Ave Unit #2 - PlanROOM NAME 101 101 1 1 1 ROOM NAME/NUMBER DOOR NUMBER WINDOW NUMBER KEYNOTE WALL TYPE REVISION NUMBER REVISION CLOUD FIXTURE/ACCESSORY INDICATOR A 1i DATE: P.M.: DRAWN BY: JOB NO.: 26081 Merit Cir, STE 111 Laguna Hills, CA 92653 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D ES I GNBUILDCNI 7/ 2 / 2 0 2 5 1 0 : 2 8 : 5 0 A M A0.1 B.N. F.M. TITLE SHEET 07.11.24 2024001108 UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT ACCESSORY DWELLING UNIT SHEET NUMBER SHEET NAME A0.1 TITLE SHEET A0.2 GENERAL NOTES A0.3 TITLE 24 A0.4 MANDATORY RESIDENTIAL MEASURES A0.5 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE A0.6 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE A1.0 EXISTING SITE PLAN A1.1 PROPOSED SITE PLAN A2.0 EXISTING FLOOR PLAN A2.1 PROPOSED FLOOR PLAN A2.2 ADU FLOOR PLAN A2.3 ELECTRICAL PLAN A3.0 NORTH AND SOUTH ELEVATIONS A3.1 EAST AND WEST ELEVATIONS A3.2 SECTION A4.0 WINDOW & DOOR SCHED., TYPES,& NOTES A5.0 DETAILS G1.0 DRIANGE PLAN  UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 DESIGNER TETSUYA TAKEUCHI EMAIL: TEDITAKEUCHI@GMAIL.COM PHONE: 949 243 4783 SUBCONTRACTOR SHALL VERIFY ALL PLANS, EXISTING DIMENSIONS & FIELD CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. ARCHITECTURAL STRUCTURAL PROJECT DESCRIPTION PROJECT INFORMATION DO NOT SCALE DRAWINGS SHEET INDEX PROJECT TEAM VICINITY MAPSYMBOLS LEGEND ABBREVIATIONS GENERAL NOTES Vinyl Composition TileV.C.T. Outside Diameter (DIM.) Powder Actuated Device Combination Paper TowelDispenser & Receptacle ReinforcedREINF. FLASH.Flashing Face of Concrete Face of Sheathing F.O.F.F.O.C.FLUOR.Fluorescent Face of Finish FTG.FT.F.S.FPRF. Footing F.O.SH. Foot or FeetFull SizeFireproof F.O.S.Face of Studs RequiredREQ.RESIL.RM.ResilientRoomR.O.Rough OpeningRUB.Rubber Expansion Bolt Expansion Joint Electrical Panelboard Electrical Water Cooler Fire ExtinguisherFire Extinguisher Cab. Flat Head Wood ScrewFire Hose Cabinet DIA.DET.DetailDiameter DR. DWG.D.S.P.DS.DWR. D.O.DN. DoorDrawer Drawing DownDISP.Dispenser Door Opening DownspoutDry Standpipe ELEV.ELEC.EL.E.J. EA.E.B. E.EachEast Elevator ElevationElectrical DIM.Dimension EXP.EXPO.EXST.E.W.C.EQPT.EQ.E.P.ENGR.ENCL. Equal ExistingExposed Enclosure Equipment Expansion Engineer F.E.C.F.E.FDN.F.D.F.B.F.A.Flat BarFloor DrainFoundation Fire Alarm EXT.Exterior FL.FIXT.FIN.F.H.W.S FinishFixtureFloor F.H.C. EMER.Emergency Not In ContrastN.N.I.C.North Not To Scale On Center N.T.S. O.A.OBS.O.C.O.D. OverallObscure NOM.Nominal P.A.D.Pre-castPRCST. P.Paint Opposite Hand Opposite O.H.OPNG.OPP.Opening OFF.Office NO. or #Number Paper Towel Dispenser Plastic Laminate PT.PointP.T.D.P.T.D/R P.LAM.PLAS.PLYWD.PR. PlasterPlywoodPair Paper Towel Reptacle Quarry TileQ.T.QTY.Quantity P.T.R.PartitionPTN. Roof DrainReferenceRefrigeratorREF.REFR.RGTR.Register RAD.R.D.RadiusR.Riser PL.Plate Verify in fieldVestibuleVertical West Wall CoveringWater Closet Wide FlangeWhere Occurs With Wood Without Water Resistant Waterproof WeightWainscot VESTV.I.F. W. W.C.WDW.F.W.O. W/WC. WT.W.R. WP.W/O WSCT. VERT. HDWE.HardwareAbove Finish Floor Construction Joint Cased Opening ACOUS. ADJ.A.D.Adjustable AcousticalArea Drain APPROX. A.F.F.ASPH.ASB.ARCH. Asphalt A.P.ALT.AL. ApproximateArchitecturalAsbestos AluminumAlternateAccess Panel AGGR.Aggregate BKG. BM.BLKG.BLK.BLDG. BITUMBD.B.B. BackingBuildingBlockBlockingBeam BoardBulletin Board Bituminous C.G.C.J. CAB. C.I.CER.CEM.C.B.Cabinet CementCeramic Corner Guard Catch Basin Cast Iron BOT.Bottom CONSTR.CONN.CONC.COL.C.O.CLR.CLO.CLKG.CalkingClosetClear ColumnConcreteConnectionConstruction CTR.CNTR.CTSKCPT.CORR.CorridorCarpet CounterCenter Countersunk CONT.Continuous CLG.Ceiling HR.HORIZ.H.M. Hour Hollow MetalHorizontal INTER.INT.INSUL.INFO.INC.I.D.IncandescentInformationInsulation IntermediateInterior Inside Diameter (Dim.) HGT.Height Kit. JT.JAN. Kitchen JanitorJoint LaboratoryLaminateLavatory MasonaryMAS.MAT.Material LAB.LAM.LAV.LKR.LT.LockerLight MET.MetalManufacturer Minimum MFR.MH.MIN.Manhole Machine BoltMedicine CabinetMechanicalMembrane M.B.M.C.MECH.MEMB. MiscellaneousMasonry Opening MUL.Mullion MISC.M.O.MTD.Mounted MIR.Mirror MaximumMAX. Diameter or RoundPound or Number# @ &AndAngleAtCenterline A.B. (N)(R)NewRelocated Anchor Bolt (E)Existing GA. GR.GND.GL.G.B.GALV.GuageGalvanizedGrab BarGlassGroundGrade HDWD.H.C.H.B.Hose BibbHollow CoreHardwood GYP.Gypsum ShelfSH. SheetSimilar Shower Sanitary Napkin DispenserSanitary Napkin ReceptacleSpecificationSee Pluming Drawing See Structural DrawingStainless Steel Square See Mechanical DrawingSheet Metal Screw SuspendedSymmetrical StorageStructural StationStandardSteel Tongue and Groove Top of Pavement ThickThreshold Top of Curb TreadTowel Bar TelephoneTerrazzo Service Sink Telephone PanelboardToilet Paper Dispenser Top of WallTelevision Typical Top of Parapet Top of Sheathing Unless Otherwise NotedUrinal Unfinished SHT.SIM. SHR. SQ. S.ST. SYM. STA.STD.STL. THK. T.B.T.C.TEL.TER. TRD. T.V. TYP. UR. UNF. T.&G. T.O.PV. U.O.N. T.P.B.T.P.D. T.O.W. THRES. S.N.D. STOR. SUSP.STRL. S.P.D. S.S.D. S.SK. S.N.R.SPEC. S.M.D.S.M.S. T.O.P. T.O.SH. See Architectural Drawing Rain Water LeaderRedwood South RWD. S. R.W.L. S.A.D. Seat Cover Dispenser Soap Dispenser See Electrical Drawing Schedule SectionS.D. S.C.D.SCHED. SECT.S.E.D. Solid CoreS.C. PROJECT DATA 1. THIS PROJECT AND ALL WORK ASSOCIATED WITH THE PROJECT SHALL CONFORM TO STATE AND LOCAL CODE JURISDICTIONS. 2. THE TERM DESIGNER AS USED IN THESE DOCUMENTS SHALL REFER TO BN DESIGN BUILD INC. 3. THE DESIGNER SHALL NOT HAVE CONTROL OR CHARGE OF AND SHALL NOT BE RESPONSIBLE FOR MEANS, METHODS, TECHNIQUES, SEQUENCE ON PROCEDURE, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK, ALL WHICH SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 4. SHORING, TEMPORARY SUPPORTS, AND SAFETY OF ERECTION BRACING DURING DEMOLITION AND / OR CONSTRUCTION IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND HAS NOT BEEN CONSIDERED BY THE STRUCTURAL ENGINEER OR THE DESIGNER. 5. ALL WORK NOTED "N.I.C." OR "NOT IN CONTRACT" IS TO BE ACCOMPLISHED BY A CONTRACTOR OTHER THAN THE GENERAL CONTRACTOR AND IS NOT TO BE PART OF THE CONSTRUCTION AGREEMENT. THE GENERAL CONTRACTOR SHALL COORDINATE WITH "OTHER"CONTRACTORS PER REQUIREMENTS ESTABLISHED BY THE OWNER. 6. THE GENERAL CONTRACTOR AND ALL SUB CONTRACTORS ARE RESPONSIBLE FOR EXAMINING CONTRACT DOCUMENTS, FIELD CONDITIONS, AND CONFIRMING THAT WORK IS BUILDABLE AS SHOWN BEFORE PROCEEDING WITH CONSTRUCTION. IF THERE ARE ANY QUESTIONS REGARDING THESE OR OTHER COORDINATION ITEMS, THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING CLARIFICATION BEFORE PROCEEDING WITH WORK IN QUESTIONS OR RELATED WORK. 7. CONTRACTOR SHALL MAINTAIN RECORD DOCUMENTS OF CONSTRUCTION CHANGES (AS-BUILT DRAWINGS) AND SHALL PROVIDE SAID DOCUMENTATION TO THE OWNER & DESIGNER UPON COMPLETION OF CONSTRUCTION. 8. THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE TO COORDINATE WITH ALL SUB CONTRACTORS PER REQUIREMENTS ESTABLISHED BY THE OWNER, WHICH ARE UNDER SEPARATE CONTRACT WITH THE OWNER. 9. THE STRUCTURAL, ELECTRICAL, MECHANICAL, & PLUMBING & OTHER DRAWINGS AND JOB SPECIFICATIONS ARE SUPPLEMENTARY TO THE DESIGNERURAL CONSTRUCTION DRAWINGS. ANY DISCREPANCY BETWEEN THESE DOCUMENTS SHALL BE IMMEDIATELY BRING TO THE ATTENTION OF THE DESIGNER FOR CLARIFICATION. 10. THEN INTENT OF DRAWINGS AND SPECIFICATIONS IS TO INCLUDE ALL LABOR, MATERIALS & SERVICES NECESSARY FOR THE COMPLETION OF ALL WORK SHOWN, DESCRIBED, OR REASONABLY IMPLIED, BUT NOT LIMITED TO THAT EXPLICITLY INDICATED ON THE CONTRACT DOCUMENTS. 11. INSTALL ALL MANUFACTURED ITEMS, MATERIALS, AND EQUIPMENT IN STRICT ACCORDANCE WITH THE MANUFACTURER RECOMMENDATIONS, UNLESS NOTED OTHERWISE. 12. ANY WORK INSTALLED IN CONFLICT WITH THE CONSTRUCTION DRAWINGS, WITHOUT THE PRIOR APPROVAL OF THE OWNER AND THE DESIGNER SHALL BE CORRECTED AT THE CONTRACTOR'S EXPENSE. 13. THE GENERAL CONTRACTOR SHALL NOTIFY THE DESIGNER IMMEDIATELY OF ANY SPECIFIED MATERIALS OR EQUIPMENT WHICH ARE EITHER UNAVAILABLE OR THAT WILL CAUSE A DELAY IN THE CONSTRUCTION COMPLETION SCHEDULE. THE CONTRACTOR SHALL SUBMIT CONFIRMATIONS OF DELIVERY DATES FOR ORDERS OF MATERIALS AND EQUIPMENT HAVING LONG LEAD TIMES. 14. ALL REQUESTS FOR SUBSTITUTIONS OF ITEMS SHALL BE SUBMITTED IN WRITING TO THE DESIGNER. SUBSTITUTIONS SHALL BE OF EQUAL QUALITY. 15. UNLESS OTHERWISE NOTED IN THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL SUBMIT 3 SETS OF SHOP DRAWINGS. FABRICATION SHALL NOT BEGIN UNTIL AFTER RECEIVING THE DESIGNER'S OR ENGINEER'S APPROVAL. 16. THE DESIGNER'S REVIEW OF SHOP DRAWINGS SHALL NOT RELIEVE THE GENERAL CONTRACTOR OR SUBCONTRACTOR FROM RESPONSIBILITY FOR DEVIATIONS FROM THE DRAWINGS AND SPECIFICATIONS UNLESS HE HAS, IN WRITING, AND BROUGHT TO THE ATTENTION OF THE DESIGNER SUCH DEVIATIONS AT THE TIME OF THE SUBMISSION, NOR SHALL IT RELIEVE HIM FROM RESPONSIBILITY FOR ERRORS OF ANY SORT IN THE SHOP DRAWINGS. 17. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED BUILDING PERMITS PRIOR TO STARTING CONSTRUCTION. 18. PRIOR TO THE ISSUANCE OF A BUILDING PERMIT, THE APPLICANT SHALL HAVE EVIDENCE OF CURRENT WORKMAN'S COMPENSATION INSURANCE COVERAGE ON FILE WITH THE STATE LABOR CODES. 19. CONTRACTOR PROVIDE CONTINUOUS INSPECTIONS AS SET FORTH IN LOCAL AND STATE CODES AND PER THE CONTRACT DOCUMENTS AS NEEDED. 20. THE CONTRACTOR, AT HIS OWN EXPENSE, SHALL KEEP THE PROJECT AND SURROUNDING AREAS FREE FROM TRASH AND DEBRIS. THE WORK SHALL BE IN CONFORMANCE WITH THE AIR & WATER POLLUTION CONTROL STANDARDS AND REGULATIONS OF THE STATE DEPARTMENT OF HEALTH. 21. CONSTRUCTION WASTE & DEBRIS SHALL BE DEPOSITED AT AN APPROPRIATE SITE. 22. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE GENERAL CLEANING OF THE JOB AFTER COMPLETION. 23. THE CONTRACTOR SHALL PROVIDE PEDESTRIAN PROTECTION, WHERE REQUIRED PER STATE AND LOCAL CODES. 24. IF TRENCHES OR EXCAVATIONS 5'-0" OR MORE IN DEPTH ARE REQUIRE, OBTAIN A BUILDING OR GRADING PERMIT. 25. NO HAZARDOUS MATERIALS SHALL BE USED OR STORED WITHIN THE BUILDING WHICH DOES NOT COMPLY WITH THE LOCAL FIRE AUTHORITY AND STATE & COUNTY REQUIREMENTS. 26. THE CONTRACTOR IS RESPONSIBLE FOR BLOCKING OFF SUPPLY & RETURN AIR GRILLES & DUCTS TO KEEP DUST FROM ENTERING INTO THE BUILDING DISTRIBUTION SYSTEMS. 27. ALL CONSTRUCTION & DEMOLITION SHALL BE DONE IN ACCORDANCE WITH LOCAL & STATE CODES. 28. UNLESS OTHERWISE NOTED OR INDICATED, ALL DIMENSIONS ON THESE DOCUMENTS SHALL BE TO FACE OF CURB, FACE OF CONCRETE, FACE OF FINISH OR CENTERLINE OF GRIDS. 29. ALL VERTICAL DIMENSIONS SHOWN ARE FROM FLOOR SLAB, UNLESS NOTED OTHERWISE. 30. DIMENSIONS TAKE PRECEDENCE. DO NOT SCALE THE DRAWINGS. LARGER DETAILED DRAWINGS TAKE PRECEDENCE OVER SMALLER SCALED DRAWINGS. 31. WHERE ELECTRICAL, MECHANICAL, OR PLUMBING ITEMS PENETRATE A FOOTING, SLAB, WALL CEILING ETC. IT IS REQUIRED THAT AN APPROPRIATELY SIZED OPENING OR CLEARANCE BE FURNISHED. CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL ITEMS WITH THE CONSTRUCTION DOCUMENTS PRIOR TO THE INSTALLATION. ANY CONFLICT WITH THE CONSTRUCTIONS DOCUMENTS, SHALL BE BROUGHT TO THE DESIGNER'S ATTENTION IMMEDIATELY. 32. THE CONTRACTOR SHALL PROVIDE AND LOCATE ACCESS PANELS IN WALLS & CEILING CONSTRUCTION AS REQUIRED TO PROVIDE ACCESS TO FIRE SPRINKLER, MECHANICAL, PLUMBING & ELECTRICAL WORK. CONTRACTOR SHALL SUBMIT A PLAN OF ALL PROPOSED ACCESS PANEL TO THE DESIGNER FOR APPROVAL. 33. ALL PENETRATIONS AT RATED CONSTRUCTION SHALL BE PROTECTED TO MAINTAIN RATING. 34. INTERIOR WALLS & CEILINGS SHALL BE INSTALLED IN ACCORDANCE TO STATE & LOCAL CODES, INCLUDING REQUIREMENTS FOR FLAME SPREAD AND SMOKE DENSITY RATINGS FOR FINISH MATERIALS. 35. ALL NEW CONSTRUCTION MATERIALS SHALL BE 100% ASBESTOS FREE. 36. ALL INSPECTIONS SHALL BE CALLED FOR AND PASSED BEFORE ANY WORK CONTINUES TO THE NEXT PHASE. 37. MANDATORY SPECIAL INSPECTIONS PER THE REQUIREMENTS OF THE ENGINEERING SUBMITTED AND I.C.C. PORTIONS OF THIS PROJECT REQUIRE SPECIAL INSPECTION. 38. NO ROOFTOP EQUIPMENT SHALL BE VISIBLE FROM THE GROUND. 39. A 4'-0" WALKWAY WILL BE MAINTAINED ALONG THE SIDE WALK IN FRONT OF THE BUILDING SITE DURING CONSTRUCTION. 40. PEDESTRIAN PROTECTION, FENCES, RAILING OR CANOPIES, SHALL BE ALONG THE PUBLIC RIGHT OF WAY IN ACCORDANCE WITH C.B.C. 41. A CONSTRUCTION FENCE SHALL BE MAINTAINED ALONG THE SIDE WALK IN FRONT OF THE BUILDING SITE DURING CONSTRUCTION. THIS FENCE SHALL BE INSTALLED PRIOR TO EXCAVATION AND/OR FOUNDATION TRENCHING. 42. TEMPORARY TOILET FACILITIES SHALL BE ON SITE DURING THE CONSTRUCTION AND WILL BE AVAILABLE ALL DURING CONSTRUCTION TIMES. STRUCTURAL ENGINEER BENJAMIN NOROUZI ASSOC. AIA, NCARB GENERAL CONTRACTOR B EMAIL: INFO@BNDESIGNBUILDINC.COM PHONE: (909) 257-7040 OWNER W BISHOP ST W BISHOP ST S R O S S S T S P A R T O N S T RICHLAND ST RICHLAND STS V A N N E S S S T MOHAMMAD JALALPOUR EMAIL: INFO@BNDESIGNBUILDINC.COM PHONE: (909) 257-7040 S0.01 CONSTRUCTION NOTES S0.02 CONSTRUCTION NOTES S1.01 TYPICAL FOUNDATION DETAILS S1.21 TYPICAL WOOD DETAILS S1.22 TYPICAL WOOD DETAILS S1.23 TYPICAL WOOD DETAILS S1.24 TYPICAL WOOD DETAILS S1.25 TYPICAL WOOD DETAILS S1.26 TYPICAL WOOD DETAILS S2.01 FOUNDATION PLAN S2.11 CEILING PLAN S2.22 ROOF PLAN S4.01 SPECIFIC DETAILS NOTE: MINIMUM 2.07 KWDC PHOTOVOLTAIC SYSTEM WILL BE SUBMITTED UNDER A SEPARATE PERMIT AND SHALL BE ISSUED PRIOR TO BUILDING FRAME INSPECTION REQUEST. • THE SCOPE WILL CONSIST OF THE FOLLOWING: NEW DETACHED ADU 730 SF WITH (3) BEDROOMS, (2) BATHROOMS, A LAUNDRY CLOSET, A COMBINED LIVING AND KITCHEN AREA, AND A COVERED ENTRY REV DATE REMARKS 1 10.03.2024 City Correction 2 06.25.2025 City Correction AREA DESCRIPTION EXISTING DEMOLISHED PROPOSED NET (E) MAIN UNIT 1,251 SF -- -- 1,251 SF (E) FRONT PORCH 80 SF -- -- 80 SF (E) GARAGE 220 SF -- -- 220 SF NEW ADU UNIT 730 SF 730 SF (ADU + COVERED ENTRY) ____________________________________________________________________ TOTAL BUILDING 1,551 SF 2,281 SF FOOTPRINT LOT COVERAGE: 1,251 + 80 + 220 + 730 / 7,004 = 0.32% REQUIREMENT PROVIDED MINIMUM SIDE YARD SETBACK 4 FEET 25'-3" - 5'-0" FEET MINIMUM REAR YARD SETBACK 4 FEET 5'-0" FEET WALL SEPARATION 5 FEET 15'-0" - 15'-9" FEET OPEN SPACE FOR ADUS 1,200 SQ.FT. 1,600 SQ.FT. ADU / SFD = 730 ADU sf / 1,251 (MAIN UNIT) = 58 % THE ADU SF / SFD SF RATIO IS FOR PARK & REC FEE PURPOSE ONLY. THE APPLICANT IS RESPONSIBLE FOR THE GIVEN “SFR SF” OF THE EXISTING PRIMARY RESIDENCE; BUILDING SAFETY STAFF ARE NOT RESPONSIBLE FOR THE ACCURACY OF THE GIVEN “SFR SF”. BUILDING DEPARTMENT: CITY OF SANTA ANA 2022 CALIFORNIA BUILDING CODE; • 2022 CALIFORNIA RESIDENTIAL CODE; • 2022 CALIFORNIA MECHANICAL CODE; • 2022 CALIFORNIA PLUMBING CODE; • 2022 CALIFORNIA ELECTRICAL CODE; • 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE; • 2022 CALIFORNIA FIRE CODE; • 2022 BUILDING ENERGY EFFICIENCY STANDARDS • 2022 INTERNATIONAL PROPERTY MAINTENANCE CODE; AND • SANTA ANA MUNICIPAL CODE OWNER NAME: TETSUYA TAKEUCHI GENERAL PLAN: LOW DENSITY RESIDENTIAL STRUCTURE TYPE: SINGLE FAMILY HOME APN: 01016309 ZONE: SD40 (SPECIFIC DEVELOPMENT) GENERAL PLAN DISTRICT: LR 7.0 OCCUPANCY CLASSIFICATION: R-3 / U TYPE OF CONSTRUCTION: TYPE V-B TOTAL OF #UNIT: 1 NUMBER OF STORIES: 1 BUILT IN : 1922 LOT SIZE: 7,004 SQ. FT. FLOOR SIZE: 1,251 SQ. FT. FLOOD ZONE, HIGH FIRE: NONE GRADING: NONE PARKING: NOT REQUIRED, ADU WITHIN 0.5 MILES OF PUBLIC TRANSIT FIRE SPRINKLERS: N/A (EXISTING PRIMARY HOME IS NOT EQUIPPED WITH FIRE SPRINKLERS) PHOTOVOLTAIC SYSTEM: TO BE FILED AS A DEFERRED SUBMITTAL - SEE CF1R OCCUPANCY LOAD: HABITABLE AREA 730 SQFT (INCLUDING BATHROOM) 2 2 GENERAL NOTES DATE: P.M.: DRAWN BY: JOB NO.: 26081 Merit Cir, STE 111 Laguna Hills, CA 92653 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D ES I GNBUILDCNI 7/ 2 / 2 0 2 5 1 0 : 2 8 : 5 2 A M A0.2 B.N. F.M. GENERAL NOTES 07.11.24 2024001108 UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT GREEN CODE BUILDING THE FLOOR SHALL BE CONCRETE SLAB ON GRADE AND SHALL BE A MINIMUM OF FOUR-INCH (4 ”) (FIVE-INCH (5”) AT WATER TREATMENT ROOM) THICK WITH MINIMUM CONCRETE STRENGTH OF 3,000-PSI. IT WILL INCLUDE ONE OF THE FOLLOWING, WIRE MESH OR FIBER MESH, AND/OR REBAR REINFORCEMENT OVER A 10 MILL MINIMUM VAPOR BARRIER (STEGO WRAP OR EQUAL) AND GRANULAR FILL PER LESSOR'S SOILS AND/OR STRUCTURAL ENGINEERING TEAM BASED ON SOIL CONDITIONS AND REPORT FROM THE SOILS ENGINEER. FINISH FLOOR ELEVATION TO BE A MINIMUM OF 8" ABOVE FINISH GRADE. THE SLAB SHALL INCLUDE PROPER EXPANSION CONTROL JOINTS. FLOOR SHALL BE LEVEL (1/8” WITH 10’ OF RUN), SMOOTH, BROOM CLEAN WITH NO ADHESIVE RESIDUES, IN A CONDITION THAT IS ACCEPTABLE TO INSTALL FLOOR COVERINGS IN ACCORDANCE WITH THE FLOORING MANUFACTURER ’S SPECIFICATIONS. CONCRETE FLOOR SHALL BE CONSTRUCTED SO THAT NO MORE THAN 3-LBS. OF MOISTURE PER 1,000SF/24 HOURS IS EMITTED PER COMPLETED CALCIUM CHLORIDE TESTING RESULTS AFTER 28 DAY CURE TIME. MEANS AND METHODS TO ACHIEVE THIS LEVEL WILL BE RESPONSIBILITY OF THE LESSOR. LESSEE REQUIRES THAT LESSOR PROVIDE MOISTURE CONTROL TREATMENT ADMIXTURE (CONCURE ADMIXTURE, NO SUBSTITUTES – CONTACT EMIL PIKULA OF CONCURE (480) 820-7171 FOR SPECIAL PRICING AND PROCEDURES) IN THE MIX DESIGN. FLOOR SLAB SHALL BE CURED ACCORDING TO ACI AND RESILIENT FLOORING INSTITUTE GUIDELINES, WATER CURE OR EMPLOY THE USE OF CONCURE 2100 CURE AND SEAL. FLOORING CONTRACTOR SHALL ADDRESS ALL CRACKS, EXPANSION JOINTS, SAW CUTS, ETC., USING CONCURE 670 CRACK FILL BINDER. CONTACT CONCURE SYSTEMS (480-820-7171) FOR APPROVAL AND METHOD FOR MOISTURE TESTING. CONCRETE SLAB NOTE 1. EACH APPLIANCE PROVIDED AND INSTALLED MEETS ENERGY STAR IF AN ENERGY STAR DESIGNATION IS APPLICABLE FOR THAT APPLIANCE. (GBC 4.506.1) 2. WHERE FUTURE SPACE FOR SOLAR IS REQUIRED, AN ELECTRICAL CONDUIT SHALL BE PROVIDED FROM THE ELECTRICAL SERVICE EQUIPMENT TO SUCH SPACE. THE CONDUIT SHALL BE ADEQUATELY SIZED BY THE DESIGNER BUT SHALL NOT BE LESS THAN ONE INCH. THE CONDUIT SHALL BE LABELED AS PER THE LOS ANGELES FIRE DEPARTMENT REQUIREMENTS AND THE ELECTRICAL PANEL SHALL BE SIZED TO ACCOMMODATE THE INSTALLATION OF A FUTURE ELECTRICAL SOLAR SYSTEM. (4.211.4) 3. THE FLOW RATES FOR ALL PLUMBING FIXTURES SHALL COMPLY WITH THE MINIMUM FLOW RATES IN TABLE 4.303.2/TABLE 9.403.2. (4.303.1) 4. WHEN SINGLE SHOWER FIXTURES ARE SERVED BY MORE THAN ONE SHOWERHEAD, THE COMBINED FLOW RATE OF ALL THE SHOWERHEADS SHALL NOT EXCEED THE MAXIMUM FLOW RATES SPECIFIED IN THE 20 PERCENT REDUCTION COLUMN CONTAINED IN TABLE 4.303.2 OR THE SHOWER SHALL BE DESIGNED TO ONLY ALLOW ONE SHOWERHEAD TO BE IN OPERATION AT A TIME.(4.303.1.3.2) 5. INSTALLED AUTOMATIC IRRIGATION SYSTEM CONTROLLERS SHALL BE WEATHER- OR SOIL-BASED CONTROLLERS. (4.304.2) 6. ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS, OR OTHER OPENINGS IN PLATES AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY, OR METAL PLATES. (4.406.1) 7. MATERIALS DELIVERED TO THE CONSTRUCTION SITE SHALL BE PROTECTED FROM RAIN OR OTHER SOURCES OF MOISTURE.(4.407.4) 8. FOR ALL NEW EQUIPMENT, A COMPLETED OPERATION AND MAINTENANCE MANUAL INCLUDING, AT A MINIMUM, THE ITEMS LISTED IN SECTION 4.410.1 OR 9.410.1, SHALL BE COMPLETED AND PLACES IN THE BUILDING AT THE TIME OF FINAL INSPECTION. (4.410.1) 9. AT LEAST 50% OF ALL AREAS RECEIVING RESILIENT FLOORING SHALL COMPLY WITH THE VOLATILE ORGANIC COMPOUND (VOC) LIMITS OR BE CERTIFIED UNDER THE RESILIENT FLOOR COVERING (RCFI) FLOORSCORE PROGRAM. (4.504.4) 10. ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, OR SHEET METAL UNTIL THE FINAL STARTUP OF THE HEATING AND COOLING EQUIPMENT. (4.504.1) 11. DESIGNERURAL PAINTS AND COATINGS, ADHESIVES, CAULKS AND SEALANTS SHALL COMPLY WITH THE VOLATILE ORGANIC COMPOUND (VOC) LIMITS. (4.504.2.1) 12. THE VOC CONTENT VERIFICATION CHECKLIST, FORM GRN 2, SHALL BE COMPLETED AND VERIFIED PRIOR TO FINAL INSPECTION APPROVAL. THE MANUFACTURER ’S SPECIFICATIONS SHOWING VOC CONTENT FOR ALL APPLICABLE PRODUCTS SHALL BE READILY AVAILABLE AT THE JOB SITE AND BE PROVIDED TO THE FIELD INSPECTOR FOR VERIFICATION. (4.504.2.4) 13. THE FORMALDEHYDE EMISSIONS VERIFICATION CHECKLIST, FORM GRN 3, SHALL BE COMPLETED PRIOR TO FINAL INSPECTION APPROVAL. THE MANUFACTURER ’S SPECIFICATIONS SHOWING FORMALDEHYDE CONTENT FOR ALL APPLICABLE WOOD PRODUCTS SHALL BE READILY AVAILABLE AT THE JOB SITE AND BE PROVIDED TO THE FIELD INSPECTOR FOR VERIFICATION. (4.504.5) 14. ALL NEW CARPET INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE TESTING AND PRODUCT REQUIREMENTS OF ONE OF THE FOLLOWING: A. CARPET AND RUG INSTITUTE ’S GREEN LABEL PLUS PROGRAM B. CALIFORNIA DEPARTMENT OF PUBLIC HEALTH STANDARD PRACTICE FOR THE TESTING OF VOCS (SPECIFICATION01350) C. NSF/ANSI 140 AT THE GOLD LEVEL D. SCIENTIFIC CERTIFICATIONS SYSTEMS INDOOR ADVANTAGE™ GOLD (4.504.3) 15. ALL NEW CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE REQUIREMENTS OF THE CARPET AND RUG INSTITUTE GREEN LABEL PROGRAM. (4.504.3) 16. BUILDING MATERIALS WITH VISIBLE SIGNS OF WATER DAMAGE SHALL NOT BE INSTALLED. WALL AND FLOOR FRAMING SHALL NOT BE ENCLOSED UNTIL IT IS INSPECTED AND FOUND TO BE SATISFACTORY BY THE BUILDING INSPECTOR. (4.505.3) 17. BATHROOM EXHAUST FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE TO THE OUTSIDE OF THE BUILDING. (4.506.1) 18. BATHROOM EXHAUST FANS, NOT FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, MUST BE CONTROLLED BY A HUMIDISTAT WHICH SHALL BE READILY ACCESSIBLE. (4.506.1) 19. THE SIZE AND LAYOUT OF THE HEATING AND AIR-CONDITIONING SYSTEMS SHALL BE IN ACCORDANCE WITH ACCA MANUAL J, ACCA 29-D AND ACCA 36-S, ASHRAE HANDBOOKS. (4.507.2 1. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITY (POWER POLES, PULL-BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES -WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES.” 2. OBTAIN PERMITS FROM PUBLIC WORKS PRIOR TO CONSTRUCTION FOR: A. TEMPORARY PEDESTRIAN PROTECTION AS REQUIRED. FOR ANY CONSTRUCTION NEAR ANY STREET OR PUBLIC AREA. 3. OUTLETS ALONG WALL COUNTER SPACE, ISLAND AND PENINSULA COUNTER SPACE IN KITCHENS SHALL HAVE A MAXIMUM SPACING OF 48". (210-52 NEC) 4. THE FIRST LIGHT IN THE NEW AND REMODELED BATHROOMS AND KITCHEN SHALL BE AN ENERGY EFFICIENT LIGHT MEETING A MINIMUM OF 40 LUMENS PER WATT (E.G. FLUORESCENT LAMP). (T-24, SEC. 130(B) & 150(K)) 5. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH NATURAL LIGHT BY MEANS OF EXTERIOR GLAZED OPENINGS IN ACCORDANCE WITH SECTION R303.1 OR SHALL BE PROVIDED WITH ARTIFICIAL LIGHT THAT IS ADEQUATE TO PROVIDE AN AVERAGE ILLUMINATION OF 6 FOOT-CANDLES OVER THE AREA OF THE ROOM AT A HEIGHT OF 30 INCHES ABOVE THE FLOOR LEVEL. (R303.1) 6. KITCHEN SINKS, LAVATORIES, BATHTUBS, SHOWERS, BIDETS, LAUNDRY TUBS AND WASHING MACHINE OUTLETS SHALL BE PROVIDED WITH HOT AND COLD WATER AND CONNECTED TO AN APPROVED WATER SUPPLY (CRC R306.4.) 7. FINISH MATERIALS INCLUDING ADHESIVES, SEALANTS, CAULKS, PAINTS AND COATING, AEROSOL PAINTS AND SYSTEMS AND COMPOSITE WOOD PRODUCTS SHALL MEET THE VOLATILE ORGANIC COMPOUND (VOC) EMISSION LIMITS IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE, CHAPTER 4 DIVISION 4.5. (R330) 8. WHEN A VAPOR RETARDER IS REQUIRED, A CAPILLARY BREAK SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE, CHAPTER 4, DIVISION 4.5. (R506.2.3.1) 9. ANNULAR SPACE AROUND PIPES, ELECTRIC CABLES, CONDUITS OR OTHER OPENINGS IN BOTTOM/SOLE PLATES AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE, CHAPTER 4, DIVISION 4.4. (R602.3.4.1) BATHROOMS 1. ALL SHOWER ENCLOSURES, REGARDLESS OF SHAPE, SHALL HAVE A MINIMUM 22" CLEARANCE AND FINISHED INTERIOR AREA OF NOT LESS THAN 1024 SQUARE INCHES (0.66 M2 ) AND SHALL BE CAPABLE OF ENCOMPASSING A 30 INCH DIAMETER (0.76 M) CIRCLE. THE MINIMUM AREA AND DIMENSIONS SHALL BE MAINTAINED TO A POINT 70 INCHES (1.8 M) ABOVE THE SHOWER DRAIN OUTLET. (CPC 410.4) 2. BATHTUB AND SHOWER FLOORS, WALLS ABOVE BATHTUBS WITH A SHOWERHEAD, AND SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR (R307.2). 3. PROVIDE ULTRA LOW FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. 4. A MIN 12" SQ. ACCESS PANEL TO THE BATHTUB TRAP SLIP JOINT CONNECTION IS REQUIRED. (PLUMBING CODE SECTION 405.2) LAUNDRY ROOM 1. CLOTHES DRYER(S) LOCATED IN AN AREA THAT IS HABITABLE OR CONTAINING FUEL BURNING APPLIANCES SHALL BE EXHAUSTED TO THE OUTSIDE OR TO AN AREA WHICH IS NOT HABITABLE AND DOES NOT CONTAIN OTHER FUEL BURNING APPLIANCES (BUT NOT BENEATH THE BUILDING OR IN THEATTIC AREA). (M.C. 504.3.1) MEANS OF EGRESS 1. PROVIDE 32" WIDE DOORS TO ALL INTERIOR ACCESSIBLE ROOMS WITHIN A DWELLING UNIT. 2. PROVIDE EMERGENCY EGRESS FROM SLEEPING ROOMS. MIN.- 24" CLEAR HT, 20" CLEAR WIDTH, 5.7 SQ.FT. MIN. AREA. GRADING AND FOUNDATION 1. IF ADVERSE SOIL CONDITIONS ARE ENCOUNTERED, A SOILS INVESTIGATION REPORT MAY BE REQUIRED. 2. FOUNDATION AND FLOOR SLABS SHALL CONFORM TO THE FOLLOWING OR THE RECOMMENDATION OF AN APPROVED SOILS REPORT : A. DEPTH OF FOOTINGS BELOW THE NATURAL AND FINISHED GRADES SHALL NOT BE LESS THAN 18 INCHES FOR EXTERIOR AND SEE STRUCTURALFOUNDATION PLAN FOR INTERIOR FOOTINGS. B. EXTERIOR WALLS AND INTERIOR BEARING WALLS SHALL BE SUPPORTED ON CONTINUOUS FOOTINGS. C. FOOTINGS SHALL BE REINFORCED WITH A MINIMUM 4 - ½ -INCH DIAMETER DEFORMED REINFORCING BARS. TWO BARS SHALL BE PLACED WITHIN 4 INCHES OF THE BOTTOM OF THE FOOTING AND TWO BARS WITHIN 4 INCHES OF THE TOP OF THE FOOTINGS. D. THE SOIL BELOW AN INTERIOR CONCRETE SLAB SHALL BE SATURATED WITH MOISTURE TO A DEPTH OF 18 INCHES PRIOR TO PLACING THE CONCRETE. E. CONCRETE FLOOR SLABS ON GRADE SHALL BE PLACED ON A 4" FILL OF COARSE AGGREGATE OR ON A MOISTURE BARRIER MEMBRANE. THE SLABS SHALL BE AT LEAST 3½ INCH THICK AND SHALL BE REINFORCED WITH #4 REBARS AT 16 INCH ON CENTER IN BOTH DIRECTIONS. 3. CONCRETE SLABS ON EXPANSIVE SOIL, COMPACTED FILL OR SLOPES OVER 1:10 SHALL BE PLACED ON A 4-INCH FILL OF COARSE AGGREGATE OR ON A BED COVERED MOISTURE BARRIER MEMBRANE. 4. OPENINGS SHALL BE AS CLOSE TO CORNERS AS PRACTICABLE AND SHALL PROVIDE CROSS VENTILATION ALONG THE LENGTH OF AT LEAST TWO OPPOSITE SIDES. OPENING SHALL HAVE 1/4 INCH CORROSION RESISTANT METAL MESH COVERING. 5. PROVIDE CORROSION RESISTANT WEEP SCREED BELOW THE STUCCO A MINIMUM OF 4" ABOVE EARTH OR 2" ABOVE PAVED AREA. 6. PROVIDE RAIN GUTTERS AND CONVEY RAIN WATER TO THE STREET. 7. SMOKE DETECTORS SHALL BE PROVIDED FOR ALL DWELLING UNITS INTENDED FOR HUMAN OCCUPANCY, UPON THE OWNER ’S APPLICATION FOR A PERMIT FOR ALTERATIONS, REPAIRS, OR ADDITIONS, EXCEEDING ONE THOUSAND DOLLARS ($1,000). (R314.6.2) 8. AN APPROVED SMOKE ALARM SHALL BE INSTALLED IN EACH SLEEPING ROOM & HALLWAY OR AREA GIVING ACCESS TO A SLEEPING ROOM, AND ON EACH STORY AND BASEMENT FOR DWELLINGS WITH MORE THAN ONE STORY. SMOKE ALARMS SHALL BE INTERCONNECTED SO THAT ACTUATION OF ONE ALARM WILL ACTIVATE ALL THE ALARMS WITHIN THE INDIVIDUAL DWELLING UNIT. IN NEW CONSTRUCTION SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY POWER SOURCE FROM THE BUILDING WIRING AND SHALL BE EQUIPPED WITH BATTERY BACK UP AND LOW BATTERY SIGNAL. (R314) 1.TERMINATION OF ALL ENVIRONMENTAL AIR DUCTS (E.G., DRYERS, BATH FANS, RANGE VENTS, ETC.) SHALL BE AT LEAST 3 FEET FROM OPENINGS INTO THE BUILDING AND EQUIPED W/ A BACK-DRAFT DAMPER. VENT DUCTS MAY BE COMBINED AND VENT AT ROOF BUT CONSULT DESIGNER FOR LOCATION. 2.ALL VENTING FANS IN BATHROOMS CONTAINING A BATHTUB, SHOWER, AND SPAS SHALL BE CONTROLLED BY A HUMIDISTAT AND BE ENERGY STAR RATED. 3.ALL BATHROOMS CONTAINING A BATHTUB, SHOWER, SPA, AND SIMILAR FIXTURES SHALL BE MECHANICALLY VENTED PER CMC, CAL. ENERGY CODE AND ASHARE 62.2. THE MECHANICAL FAN SHALL VENT ONE C.F.M. PER ONE SF OF AREA WITH A MIN. FAN SIZE OF 50 C.F.M. a.WITH A 50 CFM FAN, USE 4 ” DIAM. FLEX VENT PIPE WITH A MAX. LENGTH OF 70’ b.WITH AN 80 CFM FAN, USE 5 ” DIAM. FLEX VENT PIPE WITH A MAX. LENGTH OF 70’ 4.ALL FANS INSTALLED TO MEET ALL OF THE PRECEDING REQUIREMENTS MUST BE SPECIFIED AT A NOISE RATING OF A MAXIMUM 1 “SONE” (FOR THE CONTINUOUS USE CALCULATION) OR 3 “SONE” (FOR THE INTERMITTENT USE CALCULATION). 5.EVERY KITCHEN SHALL HAVE HOOD TO THE OUTSIDE OF THE BUILDING W/ MIN. LESS THAN 750 SF REQUIRES 85% CE OR 280 CFM . 6 ” DIAM. EQUIPPED WITH BACKDRAFT DAMPER, THAT HAS A MAXIMUM SOUND RATING OF 3-SONES AND THE REQUIREMENT FOR HERS VERIFICATION. 6.ALL NEW FIREPLACES SHALL BE DIRECT VENT, SEALED COMBUSTION, CLOSEABLE DOORS, WITH OUTSIDE AIR INTAKE 7.ANY EXISTING NON-EPA PHASE TWO WOOD BURNING FIREPLACE WILL BE REPLACED WITH A PHASE II CERTIFIED GAS UNIT FIREPLACE (M.C.C 19.80.080) OR CONVERTED TO A DEDICATED GAS LOG FIREPLACE PER CODE. 8.PRE-FABRICATED FIREPLACE INSTALLATION INSTRUCTIONS ARE TO BE ON THE JOB SITE AT THE TIME OF INSPECTION. FACTORY BUILT FIREPLACES MUST BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURERS SPECIFICATIONS & INSTRUCTIONS AND ESR - 2401. 9.GENERAL CONTRATOR TO PROVIDE GAS LINE TO EXTERIOR FIREPLACE FIRE BOX AND GAS LIGHTER SWITCH. INSTALL IN COMPLETE ACCORDANCE W/ ALL LOCAL & STATE BLDG. CODE REQUIREMENTS. FIREPLACE GAS OUTLET "LOG LIGHTER" CONTROL VALVES SHALL BE LOCATED OUTSIDE THE MINIMUM REQUIRED HEARTH AREA & WITHIN 4 FEET MAXIMUM FROM THE OUTLET, PER CPC 1211.17. 10.PER CALGREEN SECTION 4.503.1, GAS FIREPLACES SHALL BE DIRECT- VENT AND SEALED-COMBUSTION TYPE. PER CAL. ENERGY CODE SECTION 150.0(E)1, GAS FIREPLACES SHALL BE PROVIDED WITH CLOSEABLE DOORS AND OUTSIDE COMBUSTION INTAKE WITH DAMPER OR COMBUSTION AIR CONTROL DEVICE WHEN LOCATED ON AN EXTERIOR WALL. FIREPLACE INSTALLATION AND VENTING SYSTEM MUST CONFORM TO STANDARD ANSI Z21.88b 2008 CSA 2.33a 2008 VENTED GAS FIREPLACE HEATERS AND NATIONAL FUEL GAS CODE, Z223.1, LATEST EDITION. 11.NON-COMBUSTIBLE BACKER BOARD MUST BE USED TO SHEET IN FRONT OF THE FIREPLACE EXTENDING A MIN. 6" BELOW, 12" ABOVE & 10" AT SIDES. STANDARD SHEET ROCK MAY BE USED BEYOND THIS POINT IF PER MANUF. RQMTS. BACKER BOARD MATERIALS SHALL MEET CRC TABLE R702.4.2 STANDARDS, SUCH AS ASTM C1178 FOR GLASS MAT BACKING PANELS AND ASTM C1288 FOR FIBER-CEMENT BACKER BOARD. 12. PROVIDE ADEQUATE COMBUSTION AIR FOR FUEL-BURNING APPLIANCES AND WATER HEATERS WITH OPENING SHALL HAVE A FREE AREA OF NOT LESS THAN 1 SQUARE INCH PER 1000 BTU/H (0.002 M2/KW) OF THE TOTAL INPUT RATING OF APPLIANCES IN THE SPACE, BUT NOT LESS THAN 100 SQUARE INCHES (0.065 M2). ONE OPENING SHALL COMMENCE WITHIN 12 INCHES OF THE TOP OF THE ENCLOSURE, AND ONE OPENING SHALL COMMENCE WITHIN 12 INCHES OF THE BOTTOM OF THE ENCLOSURE (SEE FIGURE 701.5). THE DIMENSION OF AIR OPENINGS SHALL BE NOT LESS THAN 3 INCHES .IT MUST HAVE ADEQUATE VOLUME VOLUME SHALL BE NOT LESS THAN 50 CUBIC FEET PER 1000 BRITISH THERMAL UNITS PER HOUR (BTU/H) (4.83 M3/KW). TOTAL INPUT; ALL DOORS CLOSED). SCREENS SHALL BE NOT LESS THAN 1/4 OF AN INCH (6.4 MM) MESH. [NFPA 54:9.3.7.2] PER 2022 CMC, Section 701. 13.IF FURNACE OR WATER HEATER IS IN CRAWL SPACE THE APPLIANCE SHALL BE ON A NON-COMBUSTABLE FLOORING OR SLAB FOR MOUNTING OR ANCHORAGE W/ A MIN. 3 ” ABOVE GRADE AND LOCATED NO MORE THAN 20 ’ FROM ACCESS OPENING. EQUIPMENT SUPPORTED FROM ABOVE MUST HAVE 6 ” CLEAR ABOVE FINISH GRADE. 14.PROVIDE UNOBSTRUCTED PASSAGE WAY W/ SOLID FLOORING MIN. 24” WIDE BTWN ACCESS OPENING AND EQUIPMENT AND A 30 ” X 30” PLATFORM ON SERVICE SIDE OF THE EQUIPMENT UNLESS THE EQUIPMENT CAN BE SERVICED FROM THE ACCESS ENTRANCE. 15.HVAC SYSTEM DESIGN AND SIZING SHALL MEET CALGREEN SECTION 4.507.2 REQUIREMENTS. HEATING AND AIR CONDITIONING SYSTEMS SHALL BE SIZED, DESIGNED, AND EQUIPMENT SELECTED USING THE FOLLOWING METHODS: a.THE HEAT LOSS AND HEAT GAIN IS ESTABLISHED ACCORDING TO ANSI/ACCA 2 MANUAL J – (RESIDENTIAL LOAD CALCULATION), ASHRAE HANDBOOKS OR OTHER EQUIVALENT DESIGN SOFTWARE OR METHODS. b.DUCT SYSTEMS ARE SIZED ACCORDING TO ANSI/ACCA 1 MANUAL D – 2014 (RESIDENTIAL DUCT SYSTEMS), ASHRAE HANDBOOKS OR OTHER EQUIVALENT DESIGN SOFTWARE OR METHODS. c.SELECT HEATING AND COOLING EQUIPMENT ACCORDING TO ANSI/ACCA 3 MANUAL S – 2014 (RESIDENTIAL EQUIPMENT SELECTION) OR OTHER EQUIVALENT DESIGN SOFTWARE OR METHODS. EXCEPTION: USE OF ALTERNATE DESIGN TEMPERATURES NECESSARY TO ENSURE THE SYSTEMS FUNCTIONS ARE ACCEPTABLE. MECHANICAL NOTES (MN): 1.THE CONTRACTOR SHALL, IN WRITING, CALL TO THE ATTENTION OF THE DESIGNER ANY DISCREPANCIES BETWEEN SPECIFICATIONS, PLANS, DETAILS OR SCHEDULES. THE DESIGNER WILL THEN INFORM THE CONTRACTOR, IN WRITING, WHICH DOCUMENT TAKES PRECEDENCE. 2.FAILURE TO REPORT A CONFLICT IN THE CONTRACT DOCUMENTS SHALL BE DEEMED EVIDENCE THAT THE CONTRACTOR HAS ELECTED TO PROCEED IN THE MORE EXPENSIVE MANNER. 3.THE CONTRACTOR SHALL INVESTIGATE, VERIFY AND BE RESPONSIBLE FOR ALL CONDITIONS AND DIMENSIONS OF THE PROJECT AND SHALL NOTIFY THE DESIGNER ABOUT CONDITIONS REQUIRING MODIFICATION BEFORE PROCEEDING WITH WORK. 4.DIMENSIONS: a.IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE AND TO CROSS CHECK DETAILS AND DIMENSIONS SHOWN ON THE OVERALL DRAWINGS WITH RELATED REQUIREMENTS ON THE STRUCTURAL, MECHANICAL, AND ELECTRICAL PLANS b.USE DIMENSIONS SHOWN RATHER THAN SCALING DRAWINGS. c.ALL DIMENSIONS SHOWN ARE F.O.S. (FACE OF STUD) UNLESS CENTERLINE IS SHOWN. d.ALL DIMENSIONS ARE TO THE ROUGH UNLESS OTHERWISE SHOWN. e.CEILING HEIGHT DIMENSIONS ARE FROM FINISHED FLOOR TO FINISH FACE OF CEILING. f.ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD BEFORE PROCEEDING WITH THE WORK. 5.PRIOR TO THE START OF CONSTRUCTION, PROPERTY LINES MUST BE SURVEYED. PRIOR TO FOUNDATION INSPECTION, SETBACK STAKES MUST BE ESTABLISHED BY A LICENSED LAND SURVEYOR OR CIVIL ENGINEER TO ENSURE THAT NEW CONSTRUCTION IS LOCATED IN ACCORDANCE WITH THE APPROVED PLANS. 6.PROVIDE ALL NECESSARY ANCHORAGE BLOCKING, BACKING AND FRAMING NOT NECESSARILY LIMITED TO THE INSTALLATION OF LIGHT FIXTURES, FIRE EXTINGUISHERS, TOILET ACCESSORIES, BRACKETS, HANDICAP EQUIPMENT, AND TOILET PARTITIONS. 7.ALL DOORS NOT LOCATED BY DIMENSION ON PLAN OR DETAIL SHALL BE 5” FROM FACE OF STUD TO FACE OF NEAREST DOOR BUCK OR CENTERED ON ROOM. 8.DOOR SIZES INDICATED ON THE DRAWINGS ARE OPENING DIMENSIONS; ALLOWANCES FOR THRESHOLDS, ETC. SHALL BE TAKEN FOR NET DOOR SIZES. 9.DETAILS MARKED TYPICAL (TYP.) SHALL APPLY IN ALL CASES UNLESS SPECIFICALLY INDICATED OTHERWISE. 10.WHERE NO SPECIFIC DETAIL IS SHOWN THE FRAMING OR CONSTRUCTION SHALL BE IDENTICAL OR SIMILAR TO THAT INDICATED FOR LIKE CASES OF CONSTRUCTION ON THIS PROJECT. 11.THE CONTRACT DOCUMENTS INCLUDE THE OWNER / CONTRACTOR CONTRACT, THE PROJECT MANUAL, DESIGN SPECIFICATIONS, APPROVED SHOP DRAWINGS, THESE DRAWINGS, AND ANY DRAWINGS PROVIDED BY INTERIOR DESIGNERS ASSOCIATED WITH THE PROJECT. 12.TEMPORARY NUMBERS MUST BE INSTALLED DURING CONSTRUCTION. 13.SKYLIGHT MANUF. TO BE “VELUX” 14.EACH EMERGENCY ESCAPE WINDOW ON THE FLOOR PLAN SHALL BE LABELED. EMERGENCY ESCAPE WINDOWS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SF. THE NET CLEAR OPEN HEIGHT SHALL BE 24 ” AND WIDTH SHALL BE 20 ” DURING NORMAL OPERATION OF THE OPENING. THE EMERGENCY ESCAPE OPENING SHALL HAVE THE BOTTOM OF THE CLEAR OPENING NO HIGHER THAN 44 ” ABOVE THE FLOOR. 15.TEMPERED SAFETY GLAZING IS REQUIRED AT HAZARDOUS LOCATIONS. TEMPERED GLAZING IS REQUIRED: a.IN BOTH PANES OF FRENCH DOORS, b.ADJACENT TO DOORS WHERE WINDOW IS W/IN 24 ” ARC OF EITHER VERTICAL EDGE OF A DOOR IN A CLOSED POSITION AND LESS THAN 60 ” ABOVE A WALKING SURFACE. MEASUREMENTS ARE FROM THE NEAREST EXPOSED EDGE OF GLASS. (SEE EXCEPTIONS) c.IN SHOWERS AND BATHTUBS ENCLOSURES INCLUDING WINDOWS IF BOTTOM IS LESS THAN 60 ” ABV. STANDING SURFACE. d.ADJACENT TO STAIRS, LANDINGS AND RAMPS WITHIN 36 ” HORIZONTALLY OF A WALKING SURFACE, IF WITHIN 36 ” ABOVE THE PLANE OF THE WALKING SURFACE. C R C §R 308 (ALL MEASUREMENTS ARE TO NEAREST EXPOSED EDGE OF GLASS) e.ALL EXTERIOR GLAZING PANES ARE REQUIRED TO BE TEMPERED WHEN STRUCTURE IS SUBJECT TO W.U.I. GUIDELINES. 16.OPERABLE WINDOWS ON UPPER FLOORS MUST BE AT LEAST 36 ’’ FROM THE FLOOR WALKING SURFACE. OTHERWISE PROVIDE FALL PROTECTION FOR THE WINDOWS PER CRC R312.1. THE INTERMEDIATE RAILING TO BE SPACED SUCH THAT A 4 ’’ DIAMETER SPHERE CANNOT PASS THROUGH. 17.ADDITION: VENT ATTICS AND ENCLOSED RAFTER SPACES W/ 1/150 OF AREA AT EAVES – PROVIDE AT LEAST 1” AIRSPACE BETWEEN INSULATION AND PLYWD. SHEATHING OR VENT SPACE W/ 1/300 OF ATTIC SPACE W/ AT LEAST 40% BUT NOT MORE THAN 50% OF REQUIRED VENTILATION AREA PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE AND NOT MORE THAN 3 ’ BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE. 18. EXISTING ATTIC VENTS: VENT ALL ATTICS AND ENCLOSED RAFTER SPACES W/ 1/150 OF AREA AT EAVES – PROVIDE AT LEAST 1” AIRSPACE BETWEEN INSULATION AND PLYWD. SHEATHING OR VENT SPACE W/ 1/300 OF ATTIC SPACE W/ AT LEAST 40% BUT NOT MORE THAN 50% OF REQUIRED VENTILATION AREA PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE AND NOT MORE THAN 3 ’ BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE. 19. VENTILATION OPENINGS FOR ENCLOSED ATTICS, ENCLOSED EAVE SOFFIT SPACES, ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS, AND UNDERFLOOR VENTILATION OPENINGS SHALL BE FULLY COVERED WITH NON-CORROSIVE METAL WIRE MESH WITH OPENINGS A MINIMUM OF 1/16 ” (1.6 MM) AND NOT EXCEED 1/8 ” 20.PROVIDE ATTIC AND UNDER-STORY ACCESS LARGE ENOUGH TO REPLACE / REMOVE EQUIPMENT BUT NOT LESS THAN 22 ” X 30” WITH 30” HEADROOM W/ WEATHER STRIPS TO PREVENT BACK DRAFT. 21.ALL STAIRWAYS SHALL HAVE A 36” MIN. WIDTH AND 36 ” MIN. LANDING OR FLOOR AT THE TOP AND BOTTOM. ALSO A MAX. RISE OF 7 ¾” / MIN. RUN OF 10” MEASURED FROM THE NOSING (11 ” WHERE NO NOSING). STAIRS SHALL HAVE HANDRAILS ON EA. SIDE WITH A MIN. HEIGHT OF 34 ” AND A MAX. OF 38” WITH A GRASPABLE DIAMETER OF 1.25 ” MIN. AND 2” MAX. 1.PROVIDE A NON-REMOVABLE BACKFLOW PREVENTION DEVICE ON ALL EXTERIOR HOSE BIBS, AND LAWN SPRINKLER / IRRIGATION SYSTEMS. 2.INSTALL A SEISMIC SHUT-OFF VALVE AT GAS METER IF NONE EXIST. 3.USE COPPER PIPE ONLY FOR WATER SUPPLY PIPES. IN 1 AND 2- STORY BUILDINGS USE CAST IRON FOR WASTE LINE VERTICAL DROPS AND BTWN FLOORS OVER LIVING SPACE TO REDUCE SOUND AND ABS PLASTIC FOR VENTS. PLASTIC PIPING IS NOT ALLOWED IN 3 OR MORE STORY BLDG. 4.THE MINIMUM SLOPE FOR SANITARY LINES IS ¼” / FT 5.EA. PLUMBING VENT SHALL TERMINATE NOT LESS THAN 10 ’ FROM, OR AT LEAST 3’ ABOVE ANY OPERABLE WINDOW, DOOR, OPENING, OR AIR INTAKE. COMBINE PLUMBING VENTS AND TERMINATE ON THE NORTH FACING ROOF PLANE WHERE POSSIBLE TO AVOID IMPACT ON FUTURE SOLAR PANEL INSTALLATIONS. LOOP VENTS TO CONFORM TO CPC Section 909.1 6.PROVIDE ACCESS TO ALL PLUMBING CLEAN-OUTS INCLUDING THOSE UNDER FLOORS. 7.WATER HEATER IS TO HAVE A PRESSURE RELIEF VALVE AND DRAIN PIPE SLOPING DOWNWARD TO THE EXTERIOR OF THE BUILDING W/ TERMINATION DOWNWARD. CONDENSATE DRAIN LINE TERMINATION FOR TANKLESS WATER HEATERS AND HVAC EQUIPMENT SHALL COMPLY WITH CPC SECTION 814.1 REQUIREMENTS. 8.ANY NEW WATER HEATER MUST COMPLY WITH THE REQUIRED “FIRST HOUR RATING ” FOR THIS PROJECT PER CPC 501.0 AND TABLE 5-1. 9.FOR A WATER HEATER LOCATED IN AN ATTIC OR SPACE WHERE DAMAGE MIGHT RESULT FROM A LEAKING WATER HEATER, A WATERTIGHT PAN OF CORROSION RESISTANT MATERIAL SHALL BE INSTALLED BENEATH THE WATER HEATER W/ A MIN. ¾” DIAM. DRAIN TO AN APPROVED LOCATION. 10.WHERE A BACKFLOW PREVENTION DEVICES ARE INSTALLED, AN APPROVED EXPANSION TANK SHALL BE INSTALLED AT THE WATER HEATER. 11.APPLIANCES SHALL BE ACCESSIBLE FOR INSPECTION, SERVICE, REPAIR AND REPLACEMENT WITHOUT REMOVING PERMANENT CONSTRUCTION. A 30” X 30” PLATFORM OR S.O.G. SHALL BE PROVIDED IN FRONT OF THE APPLIANCE. 12.INSTALL APPROVED AIR GAP FITTING AT DISHWASHER TO WASTE CONNECTION PER CPC SEC. 807.3. 13.WATER CLOSET AND BIDETS MUST HAVE A MIN. OF 15 ” FROM CENTER CLEAR ON EA. SIDE AND 24 ” CLEAR IN FRONT. 14.ALL NEW AND EXISTING PLUMBING FIXTURES SHALL COMPLY TO ADOPTED CODE FOR WATER CONSERVATION REQMTS. a.TOILETS / WATER CLOSETS TO USE NO MORE THAN 1.28 GALLONS PER FLUSH b.URINALS MAY US NO MORE THAN 0.5 GALLONS PER FLUSH c.THE MAX, FLOW RATE FOR A SHOWER HEAD IS 1.8 GALLONS PER MINUTE AT 80 PSI d.INTERIOR FAUCETS MAY NOT EXCEED SPECIFIED FLOW RATES e.RESIDENTIAL LAVATORY FAUCETS MUST NOT EXCEED 1.2 GALLONS PER MINUTE AT 20 PSI f.THE MIN. FLOW RATE OF RESIDENTIAL LAVATORY FAUCETS IS 0.8 GALLONS PER MINUTE AT 20PSI 15.PROVIDE SHOWERS, TUB AND TUB-SHOWER COMBINATIONS WITH INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE OR THE THERMOSTATIC MIXING VALVE TYPE INSTALLED AND ADJUSTED PER MANUF. INSTRUCTIONS TO DELIVER A MAX. OF 120 DEG. F. 16.SHOWER STALLS SHALL BE A MINIMUM FINISHED INTERIOR OF 1,024 SQUARE INCHES, BE CAPABLE OF ENCOMPASSING A 30 INCH DIAMETER CIRCLE. ANY DOORS SHALL SWING OUT OF THE ENCLOSURE HAVE A CLEAR OPENING OF 22 INCHES MINIMUM. SHOWER SHALL HAVE A WATER DAM W/ 2 ” MIN. AND 9” MAX. ABOVE THE HIGH POINT OF THE SHOWER DRAIN. THE FINISH FLOOR OF THE SHOWER SHALL HAVE A MIN. ¼” AND MAX. ½” PER FT. PITCH TO DRAIN. WATERPROOF MEMBRANE TO EXTEND 3 ” MIN. ABOVE THE TOP OF THE DAM AT BACK AND SIDES. CONTROL VALVES LOCATED TO BE ADJUSTABLE PRIOR TO ENTERING THE SHOWER. 17.ALL GLASS BATH AND SHOWER ENCLOSURES AND DOORS SHALL BE TEMPERED AND MAINTAIN NO LESS THAN 22 ” CLEAR OPENING 18.FIXED PANELS OF TEMPERED GLASS SHOWER ENCLOSURES MUST BE ATTACHED TO THE FRAMING W/ CLIPS, TRACKS OR CHANNELS ON AT LEAST TWO SIDES. 19.CEMENTITIOUS TILE BRD. TO BE USED UNDER TUB AND IN SHOWER ENCLOSURES UNDER SMOOTH, HARD, NON-ABSORBENT TILE TO A HEIGHT OF 72 “ MIN. ABOVE DRAIN INLET. 20.GAS LINE SIZING SHALL BE BASED ON CPC SECTION 1216 16.ATTIC FURNACE INSTALLATION SHALL COMPLY WITH MINIMUM CLEARANCES PER CMC SECTION 904.2 AND ALL INSTALLATION REQUIREMENTS PER CMC SECTION 904.10. 17.JOINTS OF DUCTWORK SHALL BE MADE AIRTIGHT BY MEANS OF TAPE, MASTIC OR GASKETS. ALL JOINTS SHALL BE MECHANICALLY FASTENED. ALL DUCTS SHALL BE SUPPORTED PER MANUFACTURER INSTRUCTIONS. ALL DUCTS AND JOINTS SHALL BE SEALED AND INSULATED TO A MIN. R4.2 18.CLOSURE SYSTEMS FOR RIGID AIR DUCTS AND PLENUMS SHALL BE LISTED IN ACCORDANCE WITH UL 181A, FOR FLEXIBLE AIR DUCT SYSTEM, CLOSURE SYSTEMS SHALL BE LISTED UL181B. 19.THE LOCATION OF DUCTS INSTALLED IN CRAWL SPACES SHALL NOT OBSTRUCT ACCESS TO THE ANY AREA OF THE CRAWL SPACE. WHERE ACCESS IS REQUIRED UNDER DUCTS THERE MUST BE 18 ” CLEAR. FACTORY MADE DUCTS SHALL BE INSTALLED 4 ” CLEAR OF EARTH. 20.FOR APPLIANCES WITH VENTING SYSTEMS OTHER THAN DIRECT VENTING, TERMINATIONS SHALL BE NOT LESS THAN 4 ’ BELOW OR 4 ’ HORIZONTALLY FROM, AND NOT LESS THAN 1 ’ ABOVE A DOOR, AN OPERABLE WINDOW OR A GRAVITY AIR INLET INTO A BUILDING. THE BOTTOM OF THE VENT TERMINAL SHALL BE AT LEAST 12 ” ABOVE GRADE. 21.PROVIDE MIN. ¾″ CONDENSATE DRAIN LINE TO APPROVED LOCATION FROM COOLING EQUIPMENT OR COOLING COILS. FOR UNITS INSTALLED IN ATTIC OR FURRED SPACE, PROVIDE SECONDARY DRAIN PAN AND MIN. ¾″ DRAIN LINE OR PROVIDE A STANDING OVERFLOW AND SEPARATE SECONDARY MIN. ¾″ DRAIN LINE FOR THE PRIMARY DRAIN PAN. ROUTE THE SECONDARY DRAIN DISCHARGE TO AN APPROVED LOCATION THAT CAN BE READILY OBSERVED. 22.PRIMARY RESIDENCE: g.WATER HEATER FLUE SHALL EXTEND AT LEAST 3 ’ ABOVE THE HIGHEST POINT WHERE IT PASSES THROUGH THE ROOF AND AT LEAST 2’ HIGHER THAN ANY PORTION OF A BUILDING WITHIN A HORIZ. DISTANCE OF 10’ h.SIZE, INSTALL AND BALANCE THE HVAC / HEATING SYSTEM TO PROVIDE ADEQUATE AIR VOLUMES, REDUCED AIR FLOW NOISE AND PROPER TEMPERATURES IN EACH ROOM i.INSTALL MANUALLY ADJUSTABLE BAFFLES IN EACH SUPPLY DUCT FOR FUTURE BALANCING REQUIREMENTS. 23.PER THE CEC, ALL NEW LOW-RISE RESIDENTIAL BUILDINGS OR ADDITIONS OF 1000 SF OR GREATER ARE REQUIRED TO HAVE A WHOLE- BUILDING MECHANICAL VENTILATION SYSTEM. EXHAUST-ONLY VENTILATION REQUIREMENTS (ASHRAE 62.2): THE FOLLOWING IS A CHECKLIST OF THE MINIMUM BEST PRACTICES GUIDE FOR WHOLE-BUILDING VENTING AND LOCAL VENTILATION EXHAUST. THE VENTING SOLUTIONS MUST CONFORM TO THESE PRACTICES IN ORDER TO COMPLY WITH ASHRAE 62.2 GENERAL REQUIREMENTS: ·DESIGN REQUIREMENTS SHOWN ON BUILDING DESIGN DRAWINGS ·COMPLIANCE WITH THE VENTILATION AIRFLOW REQUIREMENTS DEMONSTRATED BY: -PRESCRIPTIVE VENTILATION SYSTEM INSPECTION. VISUALLY INSPECTING PRESCRIPTIVE DUCT SIZING AND FAN RATINGS OR -PERFORMANCE VENTILATION SYSTEM TESTING. TESTING TO CONFIRM THE DELIVERY OF THE MINIMUM VENTILATION AIRFLOW ·COMPLETE, SIGN AND MAKE AN INSTALLATION CERTIFICATE (CF-6R- MECH-05) AVAILABLE AT THE SITE WHOLE-BUILDING VENTILATION: ·WHOLE-BUILDING EXHAUST VENTILATION SYSTEM MEETS THE REQUIRED WHOLE-BUILDING VENTILATION AIRFLOW, WHICH IS CFM WHOLE-BUILDING VENTILATION REQUIREMENT CALCULATIONS EQUATION 4.1A (FROM ASHRAE 62.2): QFAN = 0.01 X AFLOOR + 7.5 X (NBR + 1) WHERE: AFLOOR = CONDITIONED FLOOR AREA, FT² NBR = NUMBER OF BEDROOMS; NOT TO BE LESS THAN ONE QFAN = VENT. AIRFLOW REQUIREMENT = MIN. FAN AIRFLOW RATING, (CFM) PLUMBING NOTES (PN): GENERAL NOTES (GN): 9. AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED IN DWELLING UNITS AND IN SLEEPING UNITS WITHIN WHICH FUEL-BURNING APPLIANCES ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES. CARBON MONOXIDE ALARM SHALL BE PROVIDED OUTSIDE OF EACH SEPARATE DWELLING UNIT SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM(S) AND ON EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS. (R315) 10. 9. 4.408.1 CONSTRUCTION WASTE MANAGEMENT. RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 65 PERCENT OF THE NON-HAZARDOUS CONSTRUCTION AND DEMOLITION WASTE IN ACCORDANCE WITH EITHER SECTION 4.408.2, 4.408.3 OR 4.408.4, OR MEET A MORE STRINGENT LOCAL CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE. REV DATE REMARKS (E) DRIVEWAY APN : 01016309 NO : 606 (E) WALK WAY (E) CONCRETE SLAB (E) AVOCADO TREE (E) ELECTRICAL PANEL 100 AMPS S V A N N E S S P. L . 5 6 . 3 ' (E) GARAGE UP UP (E) COVERED PORCH (E) VINYL FENCE, 6' H. (E) WOOD FENCE, 6' H. (E) WOOD FENCE, 6' H. (E) BLOCK FENCE, 6' H. (E) BLOCK FENCE, 6' H. (E) COVERED PATIO LAWN LAWN (E) LANDSCAPE (E) LANDSCAPE (E) TREE P. L . 5 6 . 3 ' P.L. 125' P.L. 125' 4" / 1'-0"4" / 1'-0" 6" / 1 ' - 0 " 6" / 1 ' - 0 " 4" / 1 ' - 0 " 4" / 1 ' - 0 " 2" / 1 ' - 0 " WATER METER (E) GATE (E) GAS METER (E) TREE (E) CRAWL SPACE ACCESS DOOR (E) WOOD FENCE 36" H. WILL BE REMOVED (E) WOOD FENCE 36" H. WILL BE REMOVED (E) WOOD FENCE, 6' H. EXISTING HOUSE UNDER SEPARATE PERMIT (E) AC UNIT 15 ' - 0 " 10'-7" 1,600 SF OPEN SPACE N.I.C 4" / 1 ' - 0 " 4" / 1 ' - 0 " N.I.C PREPARE A PORTION OF EXISTING YARD FOR NEW CONSTRUCTION AREA OF WORK THE EXISTING WOODEN FENCE WILL BE REMOVED ON THE SIDE OF THE PROPERTY THE EXISTING WOODEN FENCE WILL BE REMOVED ON THE SIDE OF THE PROPERTY (E ) S I D E S E T B A C K 5' - 0 " (E ) S E T B A C K 1' - 9 " (E ) S I D E S E T B A C K 14 ' - 1 1 " (E) FRONT SETBACK 27'-0" (E) REAR SETBACK 42'-9 1/2" (E) GARAGE FRONT SETBACK 63'-9" 25 ' - 3 " 33 ' - 0 " 1'-0" 1' - 0 " 1'-0" 1' - 0 " 1'-0" 1'-0" 1' - 0 " 1' - 0 " 1'-0" 1' - 0 " 1'-0" 15'-0" (E) SETBACK 41'-0" SITE BUS STOP PATH OF TRAVEL TO THE NEAREST BUS STOP (0.3 MILES) DATE: P.M.: DRAWN BY: JOB NO.: 26081 Merit Cir, STE 111 Laguna Hills, CA 92653 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D ES I GNBUILDCNI 7/ 2 / 2 0 2 5 1 0 : 2 9 : 1 1 A M A1.0 B.N. F.M. EXISTING SITE PLAN 07.11.24 2024001108 UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT 3/16" = 1'-0"1 EXISTING SITE PLAN SITE KEYNOTES 1 EXISTING CONCRETE PAD 2 WATER METER 3 EXISTING ELECTRICAL PANEL 4 PROPERTY LINE 5 EXISTING WOOD FENCE 6 EXISTING DRIVEWAY 7 EXISTING GAS METER 8 EXISTING GATE 9 EXISTING CRAWL SPACE ACCESS DOOR 10 EXISTING AC UNIT 4 21 N O R T H 0 2'-8"5'-4"10'-8" SCALE: 3/16" = 1'-0" 1 4 3 6 5 5 5 7 8 9 10 8. ALL EXTERIOR DIMENSIONS ARE FROM FACE OF FINISH. 9. CONTRACTORS TO VERIFY ALL (E) DIMENSIONS AND CONDITIONS PRIOR TO CONSTRUCTION. 10.CARE SHALL BE TAKEN TO ELIMINATE DAMAGE TO (E) MATERIALS AND SURFACES DURING CONSTRUCTION. ANY DAMAGES TO EXISTING CONSTRUCTION SHALL BE REPLACED OR REPAIRED AT NO ADDITIONAL COST. 11.INSULATION SHALL BE PROTECTED FROM DAMAGE, INCLUDING THAT DUE TO SUNLIGHT, MOISTURE, EQUIPMENT MAINTENANCE & WIND. CELLULAR FOAL INSULATION SHALL BE PROTECTED AS ABOVE OR PAINTED WITH A COATING THAT IS WATER RETARDANT & PROVIDES SHIELDING FROM SOLAR RADIATION THAT CAN CAUSE DEGRADATION OF THE MATERIAL. REV DATE REMARKS 1 10.03.2024 City Correction NOTE: THE APPLICANT/PROPERTY OWNER SHALL BE RESPONSIBLE FOR CONFIRMING ALL EXISTING UTILITY EASEMENTS AND CLEARANCE ON- SITE THAT MAY AFFECT THE PROJECT. 1. PROPOSED ADU TO BE LOCATED IN THE REAR YARD AS INDICATED ON THE SITE PLAN. 2. ALL LEVELS, DIMENSIONS AND ANGLES HAVE TO BE CHECKED AND VERIFIED PRIOR TO COMMENCING ANY WORK ON SITE. VERIFICATION SHALL INCLUDE, BUT NOT BE LIMITED TO: A. MIN. SETBACKS TO PROPERTY LINES AS INDICATED ON THE SITE PLAN. 3. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED TO BE INSTALLED IN RESIDENTIAL GROUP R OCCUPANCIES WHEN ALTERATIONS, REPAIRS, OR ADDITIONS REQUIRING A BUILDING PERMIT OCCUR. SMOKE AND CARBON MONOXIDE ALARMS SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS, AND APPLICABLE PROVISIONS OF CBC, CRC, CFC, AND COUNTY OR MUNICIPAL STANDARDS. ADDRESS IDENTIFICATION NOTES: 1. ADDRESS SPEC - THE ADDRESS IDENTIFICATION CHARACTERS SHALL CONTRAST WITH THEIR BACKGROUND, AND EACH CHARACTER SHALL BE NOT LESS THAN 4-INCHES IN HEIGHT WITH A STROKE WIDTH OF NOT LESS THAN 0.5- INCH. PUBLIC RIGHT OF WAY: 1. THERE IS AN EXISTING CURB CUT FOR THE PROPERTY, TO REMAIN. THE PROJECT DOES NOT INCLUDE ANY WORK IN THE PUBLIC RIGHT OF WAY. UTILITIES: 1. UTILITY CONNECTIONS ARE INDICATED ON THE SITE PLAN AND LABELED. 2. THE PROJECT CONTACT AND/OR THEIR LICENSED CONTRACTOR SHALL CONFIRM THE LOCATION, SIZE AND CAPACITY OF ALL UTILITY LINES INCLUDING, BUT NOT LIMITED TO, GAS SERVICE, WATER SERVICE, SEWER/WASTE SERVICE, ELECTRICITY AND DATA SERVICE. THE PROPOSED SERVICE CONNECTIONS FOR THE ADU SHALL BE VERIFIED AND DETERMINED TO BE VIABLE CONNECTION PATHS PRIOR TO COMMENCING WORK ON THE PROJECT. IF ANY REQUIRED UTILITY LINE OR CONNECTION IS MISSING, DISPLACED OR OTHERWISE INACCURATE, THE CONTRACTOR AND/OR PROJECT CONTACT SHALL NOTIFY ALL PARTIES AND A REVISION TO THE PLANS SHALL BE MADE. 3. WATER SUPPLY: ADU TO BE CONNECTED TO THE COLD WATER SUPPLY TO THE PRIMARY HOME. 4. SEWER: ADU TO BE CONNECTED THE SEWER LINE ON THE PROPERTY. 5. ELECTRICAL ENERGY: PROVIDE MAIN SWITCH FOR THE ADU IN THE MAIN HOUSE ELECTRICAL PANEL BOARD. INSTALL ELECTRICAL PANEL IN THE ADU. 6. GAS: ADU TO BE CONNECTED TO THE GAS SUPPLY TO THE PRIMARY HOME. 7. WATER MAINS AND SERVICES, INCLUDING METERS, MUST BE LOCATED AT LEAST 10' HORIZONTALLY FROM OR AT LEAST 1' VERTICALLY ABOVE ANY PARALLEL PIPELINE CONVEYING UNTREATED SEWAGE (SEWER LATERAL). CALIFORNIA WATERWORKS STANDARDS, TITLE 22, CHAPTER 16, SECTION 64572. GENERAL SITE PLAN NOTES:GENERAL SITE PLAN NOTES: (E) DRIVEWAY APN : 01016309 NO : 606 (E) CONCRETE SLAB (E) ELECTRICAL PANEL 100 AMPS S V A N N E S S P. L . 5 6 . 3 ' (E) GARAGE UP UP (E) COVERED PORCH (E) WOOD FENCE, 6' H. (E) BLOCK FENCE, 6' H. (E) COVERED PATIO ADU 730 SF LAWN LAWN (E) LANDSCAPE (E) LANDSCAPE (E) TREE P. L . 5 6 . 3 ' P.L. 125' P.L. 125' 4" / 1'-0"4" / 1'-0" 6" / 1 ' - 0 " 6" / 1 ' - 0 " 4" / 1 ' - 0 " 4" / 1 ' - 0 " 2" / 1 ' - 0 " WATER METER (E) GAS METER (E) TREE (E) WOOD FENCE 36" H. (E) WOOD FENCE 36" H. EXISTING HOUSE (E) AC UNIT 10'-7" N.I.C 4" / 1 ' - 0 " 4" / 1 ' - 0 " N.I.C 4" / 1'-0"4" / 1'-0" 4" / 1 ' - 0 " 4" / 1 ' - 0 " SE T B A C K 25 ' - 3 " SETBACK 5'-0" WALL SEPARATION 15'-0" WA L L S E P A R A T I O N 15 ' - 9 " SE T B A C K 5' - 0 " SETBACK 4'-0" SE T B A C K 4' - 0 " SE T B A C K 24 ' - 3 " 1' - 0 " (N) CONCRETE PAD(N) WALK WAY ENTRY (E) AVOCADO TREE HAS BEEN APPROVED UNDER SEPARATE PERMIT 4' - 0 " 4'-0" (N) 1GL. SHURBS 24” BOX CANOPY TREE (N) 5GL. SHURBS 24” BOX CANOPY TREE (N) 5GL. SHURBS (N) 1GL. SHURBS (N) 1GL. SHURBS (N) 1GL. SHURBS HARDSCAPE/PAVEMENT PA T H O F T R A V E L PATH OF TRAVEL (N) SANDBAGS (N) SANDBAGS THE GRADE SHALL FALL NOT FEWER THAN 6IN WITHIN THE FIRST 10FT. WHERE LOT LINES, WALLS, SLOPES OR OTHER PHYSICAL BARRIERS PROHIBIT 6IN OF FALL WITHIN 10FT, DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE.IMPERVIOUS SURFACES WITHIN 10FT OF THE BUILDING FOUNDATION SHALL BE SLOPED NOT LESS THAN 2% AWAY FOR THE BUILDING PER 2022 CRC, SECTION R401.3. EXISTING 4" D SEWER LINE NEW 4" D SEWER LINE (E) CLEANOUT CITY LATERAL(E) CLEANOUT NEW CLEANOUT SE D I M E N T B A R R I E R (N) SANDBAGS 5% SLOPE 2% SLOPE 5% 5% 5% 5% SLOPE 5% SLOPE 2% SLOPE 2% SLOPE 2%THE PROPOSED ROOF SHINGLES MATCHES THE PRIMARY DWELLING UNIT MATERIAL, STYLE, AND COLOR. NOTE: LOCATION OF DS CONNECT TO EXISTING DRAINS/ STORMWATE GALVANIZED STEEL HALF ROUND DORMER VENT. REFER TO ATTIC CALCULATION ROOF VENT W/ SCREEN ROOF VENTS W/ WIRE MESH OF LESS THAN 1/4" OPENING 2.84 2.84 2.84 2.84 2.84 DOWNSPOUT GRAY AREA: PROTECT UNDERSIDE OF EAVE WITH 1-HOUR PROTECTION AND NO EAVE VENTS. TYPE X GYPSUMSHEATHING UNDER SOFFIT AND WALL MATERIAL (TYP.) 1'-0" 1' - 0 " 1'-0"ENCLOSURE OF TANKLESS W.H. 199,000BTU MINI SPLIT ELECTRICAL SUB PANEL 100A ASPHALT SHINGLE CLASS A ESR 1475 TWO LAYERS OF UNDERLAYMENT INSTALLED PER CRC TBL. R905.1.1(2) (E ) S I D E S E T B A C K 5' - 0 " (E ) S E T B A C K 1' - 9 " (E ) S I D E S E T B A C K 14 ' - 1 1 " WALL SEPARATION 3'-0" WALL SEPARATION 5'-0" (E) FRONT SETBACK 27'-0" (E) REAR SETBACK 42'-9 1/2" (N) CANOPY TREES (E) GARAGE FRONT SETBACK 63'-9" (N) CANOPY TREES WATER HEATER VENT 1'-0" 1' - 0 " 1'-0" 1' - 0 " 1'-0" 1'-0" 1' - 0 " 1' - 0 " 1'-0" 1' - 0 " 1'-0" (E) CRAWL SPACE ACCESS DOOR (E) SETBACK 41'-0" 3' - 0 " 2'-6" 2' - 6 " 2.84 RIDGE VALL E Y RI D G E VALL E Y A5.0 9 A5.0 9 EAVE VENT, SEE SPEEC. EAVE VENT, SEE SPEEC. EAVE VENT, SEE SPEEC. 4" / 1 ' - 0 " 4" / 1'-0" 4" / 1 ' - 0 " 2'-8" 2' - 3 " 1'-0" 1' - 0 " 1'-0" 1' - 6 " 1" C O P P E R P I P E RI G I D N O N - M E T A L L I C EL E C T R I C A L C O N D U I T 4" N O N - M E T A L L I C S E W E R L I N E SEWER LINES - EXISTING AND PROPOSED NEW LINES: 4" PVC SANITARY LINE WITH 1/4" - 1' MIN. FALL. JOINTS AND INSPECTIONS POINTS TO COMPLY WITH APPLICABLE CODES W W WATER LINES - EXISTING AND PROPOSED NEW LINES: 3/4" PVC WATER LINE. PIPES, JOINTS AND CONNECTIONS TO COMPLY WITH APPLICABLE CODES GAS LINES - EXISTING AND PROPOSED NEW LINES: 3/4" NATURAL GAS SUPPLY LINES. PIPES, JOINTS AND CONNECTIONS TO COMPLY WITH RELEVANT CODES G G ELECTRICAL SERVICE LINE TO ADUEE COAX/DATA SERVICE LINE TO ADUDD EXISTING WALLS TO REMAIN PROPOSED WALLS LANDSCAPE (PERMEABLE) CONCRETE SURFACE (IMPERMEABLE) TILE SURFACE (PERMEABLE) GRAVEL (PERMEABLE) W E G UTILITY METERS AND SHUT-OFFS: WATER, ELECTRICAL, GAS SHUT-OFF VALVE WASTE LINE CLEANOUT DATE: P.M.: DRAWN BY: JOB NO.: 26081 Merit Cir, STE 111 Laguna Hills, CA 92653 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D ES I GNBUILDCNI 7/ 2 / 2 0 2 5 1 0 : 2 9 : 1 5 A M A1.1 B.N. F.M. PROPOSED SITE PLAN 07.11.24 2024001108 UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT 4 21 N O R T H 0 2'-8"5'-4"10'-8" SCALE: 3/16" = 1'-0" 1 4 3 6 5 5 5 7 9 10 3/16" = 1'-0"1 PROPOSED SITE PLAN DRAINAGE NOTES: 1. RAINWATER DISTRIBUTION OVER PERMEABLE AREA ON THE PROPERTY. 2. GRADING TO SLOPE 5% AWAY FROM THE WALLS, FOR MIN. 10'. WHERE LESS THAN 10' SPACE IS AVAILABLE - SEE BELOW. 3. SWALES ALONG SIDE WALLS OF THE ADU TO DIVERT STORMWATER TO THE STREET. 4. SWALES ALONG SIDE WALLS OF THE ADU TO DIVERT STORMWATER OVER PERMEABLE AREA ON THE PROPERTY (LANDSCAPE). SITE PREPARATION NOTES: 1. TAKE NECESSARY PRECAUTIONS TO MINIMIZE DISTURBANCE OF EXISTING VEGETATION TO REMAIN. 2. SOIL DISTURBANCE SHALL BE LIMITED TO THAT WHICH IS NECESSARY FOR SITE PREPARATION AS DESCRIBED IN THIS SECTION INCLUDING UTILITY CONNECTIONS. PREVENT WATER FROM RUNNING INTO EXCAVATED AREAS. 3. BACKFILL MATERIAL SHALL BE FREE OF ORGANIC MATTER AND ROCKS OR LUMPS OVER 6 INCHES (2 INCHES AT UTILITY TRENCHES). COMPACT BACKFILL TO AT LEAST 90 PERCENT RELATIVE COMPACTION PER ASTM D-1557; IN LIFTS NOT EXCEEDING 8 INCHES UNCOMPACTED. 4. DEPRESSION FROM REMOVAL OF OBSTRUCTIONS SHALL BE OPENED TO WORKING SIZE; REMOVE DEBRIS AND SOFT MATERIAL; BACKFILL AND COMPACT AS NECESSARY. 5. SURFACE DRAINAGE SHALL SLOPE 3% FROM BUILDING FOUNDATIONS FOR A MINIMUM OF 5 FEET AND AT LEAST 1% TO SUITABLE COLLECTION POINTS. 6. TRENCHING SHALL BE TRUE TO GRADES INDICATED. EXTEND UTILITY TRENCHES TO BE SUFFICIENT DEPTH STANDARDS AND LOCAL CODES. PROPERLY SUPPORT TRENCHES. 7. UNUSUAL CONDITIONS NOT COVERED IN THE PROJECT, IF ENCOUNTERED, SHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT'S CONTACT AND RESOLVED ACCORDING TO APPLICABLE CODES. 8. IF DEEMED NECESSARY, HAZARDOUS WASTE TESTING SHALL BE CONDUCTED INCLUDING ASBESTOS TESTING & REMEDIATION. 9. STORM WATER DRAINAGE AND RETENTION SHALL BE FURNISHED DURING CONSTRUCTION. MEANS OF DRAINAGE AND RETENTION AS FOLLOWS: A. STORM WATER CONVEYED TO A PUBLIC DRAINAGE SYSTEM SHALL BE FILTERED BY A BARRIER SYSTEM, WATTLES OR OTHER APPROVED METHOD. B. IMPLEMENT STORM WATER MANAGEMENT METHODS PER THE JURISDICTION'S MUNICIPAL CODE, ORDINANCE, OR OTHER REQUIREMENTS. C. GRADING AND PAVING SHALL BE CONDUCTED TO MANAGE SURFACE WATER INCLUDE SWALES, WATER COLLECTION AND DISPOSAL SYSTEMS, FRENCH DRAINS, WATER RETENTION GARDENS OR OTHER MEASURES AS INDICATED OR NECESSARY TO KEEP SURFACE WATER AWAY FROM BUILDINGS AND AID IN GROUNDWATER RECHARGE. 10. AVOID LAND-DISTURBING WORK DURING ANY WET WEATHER SEASON. PROJECT CONTACT TO VERIFY CLIMATE AND WEATHER FORECASTS PRIOR TO COMMENCING THE LAND- DISTURBING WORK. 11. EXISTING VEGETATION TO REMAIN SHALL BE PROTECTED, INSTALL APPROPRIATE/PROTECTIVE FENCING/PERIMETER CONTROLS PRIOR TO COMMENCING WORK. 12. ALL IMPERVIOUS SURFACES SHALL BE SWEPT (NOT WASHED OR HOSED DOWN), AND MAINTAINED FREE OF DEBRIS AND ACCUMULATIONS OF DIRT. 13. ALL CONSTRUCTION WASTE SHALL BE CONTAINED ON SITE AND COVERED, INCLUDING TRASH, PAINT, GROUT, CONCRETE, ETC. ANY WASH OUT FACILITY SHALL BE CONTAINED, MAINTAINED, AND ITS CONTENTS DISPOSED OF PROPERLY; NO MATERIAL SHALL BE WASHED INTO THE STREET. 14. CATCH BASINS AND/OR DROP INLETS THAT RECEIVE STORM WATER MUST BE COVERED OR OTHERWISE PROTECTED FROM RECEIVING SEDIMENT, MUD, DIRT, OR ANY DEBRIS, INCLUDING PRIOR GUTTER FILTRATION AS APPROPRIATE AND IN A MANNER NOT IMPEDING TRAFFIC SAFETY. 15. PROPERLY INSTALLED SILT FENCE OR EQUIVALENT CONTROL SHALL BE EVIDENT ALONG SITE PERIMETER TO PREVENT MOVEMENT OF SEDIMENT AND DEBRIS OFF-SITE. NO SEDIMENT MAY LEAVE OR RUNOFF THE SITE. PROJECT CONTACT SHALL VERIFY, IF APPLICABLE, IF ADDITIONAL SLOPE STABILIZATION BMPS SHALL BE IMPLEMENTED TO PREVENT SLOPE EROSION AND SEDIMENTATION ON-SITE AND OFF. 16. ALL STOCKPILES SHALL BE CONTAINED AND COVERED WHEN NOT ACTIVE, AND SECURED AT THE END OF EACH DAY. STOCKPILES SHALL BE SECURELY COVERED OVERNIGHT, AND PRIOR TO, DURING, AND AFTER RAIN EVENTS. NO MATERIALS SHALL LEAVE THE SITE OR BE MOVED INTO THE STREET. 17. PROJECT CONTACT AND SUBCONTRACTORS MUST ENSURE ALL CONSTRUCTION VEHICLES AND EQUIPMENT ARE MAINTAINED IN WORKING ORDER, AND WILL NOT CAUSE DIRT, MUD, OIL, GREASE, OR FUEL TO BE DISCHARGED OR TRACKED OFF-SITE INTO THE STREET. SITE KEYNOTES 1 EXISTING CONCRETE PAD 2 WATER METER 3 EXISTING ELECTRICAL PANEL 4 PROPERTY LINE 5 EXISTING WOOD FENCE 6 EXISTING DRIVEWAY 7 EXISTING GAS METER 8 EXISTING GATE 9 EXISTING CRAWL SPACE ACCESS DOOR 10 EXISTING AC UNIT SITE PLAN LEGEND ATTIC VENTILATION CALCULATION UNIT #2 NEW ATTIC SPACE AREA 730 S.F. REQUIRED VENTILATION 730 / 150 = 4.8 NFA SQ. FT. 4.8 X 144 = 691 SQ. INCHES OF NFA (A LEAST 40% MINIMUM FOR RIDEG AND 60% MAXIMUM AT THE UPPER PORTION OF THE ROOF EAVE) 691 40 % 276 SF IN ROOF VENTS (276 / 60 = 4.6 = 6 ROOF VENT PROVIDED ) 691 60% 414 SF IN EAVE/ROOF VENTS (414 / 39 = 10.6 = 11 ROOF VENT PROVIDED ) REV DATE REMARKS 1 10.03.2024 City Correction 2 06.25.2025 City Correction NOTE: THE APPLICANT/PROPERTY OWNER SHALL BE RESPONSIBLE FOR CONFIRMING ALL EXISTING UTILITY EASEMENTS AND CLEARANCE ON- SITE THAT MAY AFFECT THE PROJECT. 2.84 ROOF VENT 2 2 2 2 2 2 EX. WALL TO REMAIN EX. WALL TO BE REMOVED AREA NOT IN CONTRACT (N.I.C.) EX. DOOR TO REMAIN 1 2 3 INTERIOR WALL 1 HOUR FIRE RATED WALL EXTERIOR WALL FLOOR CEILING ROOF 2 B 3 C 1 A TYPICAL, FIRE RATED WALL 2X4 WOOD STUDS @ 16" O.C. w/ 5/8" TYPE 'X' GYP. ONE. SIDE W/ SOUND INSULATION INTERIOR WALL 2X4 WOOD STUDS @ 16" O.C. w/ 1/2" BD. EA. SIDE w/ SOUND INSULATION EXTERIOR WALL 1/2" GYP. BD. 2X4 WOOD STUDS @ 16" O.C. INSULATION R -15 w/ 5/8" PLYWOOD, 1" RIGID INSULATION, BUILDING 2 LAYERS PAPER, AIR SPACE, WOOD SIDING (E) ELECTRICAL PANEL 100 AMP (E) WOOD FENCE, 6' H. (E) WOOD FENCE, 6' H. (E) BLOCK FENCE, 6' H. (E) BLOCK FENCE, 6' H. (E) COVERED STORAGE P. L . 5 6 . 3 ' (E) AVOCADO TREE (E) TREE (E) TREE 8' - 6 " 17 ' - 3 1 / 2 " WALL SEPARATION 5'-0" WA L L S E P A R A T I O N 15 ' - 0 " SETBACK 5'-0"22'-9 1/2" WALL SEPARATION 15'-0" SE T B A C K 25 ' - 3 " 11 ' - 0 " 11 ' - 0 " 11'-5" 5'-0" 3'-4 1/2" 9'-2" 3'-4 1/2" 8'-9" 7'-10" 3' - 0 " 2' - 0 " TEMP. GLASS 2' - 0 " 2' - 1 0 " 2' - 1 0 " 6' - 9 " 4' - 3 " KITCHEN LIVING ROOM MASTER BEDROOMBATH WALK IN CLOSET DINING ROOM MASTER BATH STACK. LAUNDRY REF. SINK DW 7' - 8 " 9'-5" 8'-2 1/2"3'-0"2'-6"5"2'-6"1'-0"4'-0"1'-6 1/2"3'-0"4"3'-0"1'-6 1/2" 3' - 1 1 " 3' - 0 " 1' - 7 " 25 ' - 9 1 / 2 " SE T B A C K 5' - 0 " 31'-0" SETBACK 5'-0" 1'-8 1/2"3'-0"4"3'-0"5'-8 1/2"2'-0"7'-0 1/2"3'-0"4"3'-0"1'-10 1/2" TV LANDING 3' - 0 " BEDROOM #2 A3 . 1 1 A3 . 1 2 A3 . 0 1 A3 . 0 2 2'-0"2'-10"3'-0" 5' - 0 " 1'-7 1/2" CLOSET 3'-10"2'-0"2'-4" TEMP. GLASS DS DS DS DS DS (N) WALKWAY ALL NONABSORBENT SURFACE MATERIAL SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FT ABOVE THE FLOOR 1/2" THRESHOLD SAFETY GLAZING NOTE: IF SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, THE COMBINED FLOW RATE OF ALL SHOWERHEADS AND/OR OTHER SHOWER OUTLETS CONTROL BY A SINGLE VALVE SHALL NOT EXCEED 1.8 GPM AT 80 PSI. OR THE SHOWER SHALL BE DESIGNED TO ALLOW ONLY ONE SHOWER OUTLET TO BE IN OPERATION AT A TIME. SINK CENTERED TO KITCHEN WINDOW, CONTRACTOR TO VERIFY 03 02 03 03 02 02 02 01 05 04 06 03 05 02 07 01 01 03 03 01 02 0101020101 DROPPED CEILLING 8'-0" EGRESS EGRESS SAFETY GLAZINGSAFETY GLAZING SAFETY GLAZING SAFETY GLAZING SAFETY GLAZING TANKLESS WATER HEATER 199,000BTU ALL NONABSORBENT SURFACE MATERIAL SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FT ABOVE THE FLOOR THE INTERIOR FINISHED FLOOR SHALL BE NOT MORE THAN 1/2" LOWER THAN THE TOP OF THE DOOR THRESHOLD. EXTERIOR DOOR LANDING SHALL BE NOT MORE THAN 73/4IN BELOW THE TOP OF THE DOOR THRESHOLD PER 2022 CRC, SECTION R311.3.1 2.462.46 2.17 2.18 2.182.93 2.14 2.15 LOUVER DOOR 2.51 2.50 03 3' - 0 " 8' - 0 " (N) CANOPY TREES 4'-0" (N) CONCRETE PAD MINI SPLIT 1 A3.2 ENTRY SD S/CSD NATURAL LIGHT 8% REQUIRED 100 SQ. FT. X 8%= 8 SQ. FT. WINDOW 01 X 2 = 24 SQ. FT. PROVIDED NATURAL VENTILATION 4% REQUIRED 100 SQ. FT. X 4%= 4 SQ. FT. WINDOW 01 X 2 = 24 SQ. FT. PROVIDED 24 SQ. FT. X 50%= 12 SQ. FT. PROVIDED NATURAL LIGHT 8% REQUIRED 110 SQ. FT. X 8%= 8.8 SQ. FT. WINDOW 01 X 2 = 24 SQ. FT. PROVIDED NATURAL VENTILATION 4% REQUIRED 115 SQ. FT. X 4%= 4.4 SQ. FT. WINDOW 01 X 2 = 24 SQ. FT. PROVIDED 24 SQ. FT. X 50%= 12 SQ. FT. PROVIDED (N) CANOPY TREES 2'-6" 2' - 6 " ENCLOSURE OF WATER HEATER ELECTRICAL SUB PANEL 100A 3' - 0 " 3' - 0 " 9'-4 1/2"6'-8" 13 ' - 6 " 21'-10 1/2" 3' - 0 " 4" SLAB UNDER MINI SPLIT UNIT 03 2 A3.2 2'-6"1' - 1 0 " ATTIC ACCESS MINI SPLIT BLOWER MINI SPLIT BLOWER MINI SPLIT BLOWER MINI SPLIT BLOWER COMMON AREA = 400 SQ.FT PRIVATE AREA = 330 SQ.FT TOTAL AREA = 730 SQ.FT DATE: P.M.: DRAWN BY: JOB NO.: 26081 Merit Cir, STE 111 Laguna Hills, CA 92653 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D ES I GNBUILDCNI 7/ 2 / 2 0 2 5 1 0 : 2 9 : 1 9 A M A2.2 B.N. F.M. ADU FLOOR PLAN 07.11.24 2024001108 UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT 0 1'-4"2'-8"5'-4" SCALE: 3/8" = 1'-0" 2.14 36" GAS RANGE / OVEN AND OVERHEAD EXHAUST HOOD VENTED TO EXTERIOR SEE MECHANICAL NOTES ON SHEET A0.2 FOR ADDITIONAL VENTING REQUIREMENTS 2.15 36" KITCHEN SINK WITH GARBAGE DISPOSAL - VERIFY DIMENSIONS WITH MANUFACTURER'S SPECIFICATIONS. 2.17 LAUNDRY-APPLIANCES, CABINETS AND FIXTURES AS SELECTED BY OWNERS, INSTALL ENERGY STAR WASHERS DRYERS AS SELECTED BY OWNERS. WASHING MACHINE SHALL MEET CEE TIER 2 REQUIREMENTS (MODIFIED ENERGY FACTOR 20, WATER FACTOR 60).SEE INTERIOR DESIGN/CABINET CONSUL TANT DRAWINGS FOR ADDITIONAL INFORMATION. INSTALL UTILITIES FOR LAUNDRY APPLIANCES. SEE UTILITY PLANS FOR ADDITIONAL INFORMATION. PROVIDE ELEVATED COUNTER OVER TOP OF FRONT LOADING WASHER/DRYER AS REQUIRED COORDINATE WITH CABINET SUB 2.18 BATHROOMS: ALL FIXTURES AND FINISHES AS SELECTED. TANK TYPE PORCELAIN WATER CLOSET . ENAMEL LAVS. PROVIDE PLUMBING PER CODE FOR ALL FIXTURES AND SEPARATE SHOWER. MIRROR OVER LAVS AS SELECTED BY INTRIOR DESIGN CONSULTANT OR CONTRACTOR. 2.46 DOWNSPOUT 2.50 PROPOSED NEW CLOSET DOOR 2.51 PROPOSED NEW POCKET DOOR 2.93 30" BUILT- IN ENERGY STAR REFRIGERATOR W/ WATER LINES FOR ICEMAKERS GENERAL NOTES 1- CONTRACTOR SHALL NOT SCALE , DRIVER OR REQUEST DIMENSIONS FROM THE STRUCTURAL ENGINEER, PLUMBING ENGINEER,CIVIL ENGINEER OR ELECTRICAL ENGINEER... FOR ANY ITEMS ON THE DOCUMENTS. ALL DIMENSIONS NEEDED WILLBE REQUESTED OF THE DESIGNER IN WRITING IN THE FORM OF AN RFI.(FAILURE TO ADHERE TO THIS PROCESS WILLRESULT IN DENIAL OF CHANGE ORDERS ) 2- GENERAL CONTRACTOR SHALL NOT EXCLUDE (ANY) PORTION OF WORK, OR RELATED WORK FOR (ANY)PORTION OF THE WORK SHOWN OR REFERENCED ON THE DOCUMENTS. A. ALL DIMENSIONS FOR THE PROJECT SHALL BE OBTAINED FROM THE DESIGNERURAL DRAWING,IN THE EVENT THAT THEY ARE NOT PROVIDED THE GC SHALL ASK THE DESIGNER IN WRITING IN THE FORM OF AN RFI. B. IN THE EVENT OF ANITEM BEING UNCLEAR ON THE DRAWINGS DURING BIDDING,THE GC SHALL ASK(IN A BID RFI)TO THE DESIGNER FOR THE INFO, THE GC SHALL ASK THIS INFO IN A TIMLY MANNER SO AS TO GIVE THE DESIGNER TIME TO ANSWER AND DISTRIBUTETO ALL PARTIES. IN TEH EVENT THAT THE GC FAILS TO CLARIFY THIS INFO DUE TO OVERLOOKING IT OR NOT RECEIVING AN ANSWER FORM THEDESIGNER, GC SHALL IDENTIFY THE ITEM/S IN QUETION IN THEIR BID CLARIFICATIONS. C. GC SHALL REVIEW ALL SUBCONTRACTOR SCOPE TO THE FULL-SET OF DOCUMENTS,IT IS GC RESPONSIBILITY TO UNDERSTAND AND DISCUSS SUB-CONTRACTOR SCOPE ATTHE TIME OF BID TO THE POINT THAT THEY FEEL COMFOR TABLE THAT THE DRAWING INTENT HAS BEEN SATISFIED. ANY UNCLEAR ITEMS SHALL BE DISCUSSED WITH THE SUBCONTRACTOR TO CLARIFY THE NEED FOR A BID RFI 3- ALL DIMENSIONS ARE TO STRUCTURE-FACE OF STUD OR STRUCTURE CONCRETE WALL. 4- GENERAL CONTRACTOR TO VERIFY ALL DOOR FRAME WIDTHS,COORDINATE WITH WALL TYPE SCHEDULE FOR WALL THICKNESS REFER TO DOOR SCHEDULE. 5-PROVIDE OPENING FOR DOOR SIZE SCHEDULE, JAMBS ARE FLUSH AS SHOWN OR AS DIMENSIONED GREEN CODE BUILDING 1. THE FLOW RATES FOR ALL PLUMBING FIXTURES SHALL COMPLY WITH THE MINIMUM FLOW RATES IN TABLE 4.303.2/TABLE 9.403.2. (4.303.1 PLUMBING NOTES 1. PROVIDE A NON-REMOVABLE BACKFLOW PREVENTION DEVICE ON ALL EXTERIOR HOSE BIBS, AND LAWN SPRINKLER / IRRIGATION SYSTEMS. WALL LEGEND FLOOR PLAN GENERAL NOTES:FLOOR PLAN GENERAL NOTES: 1. SEE SHEET A4.0 FOR ASSEMBLIES AND ROOM FINISH, WINDOWS, DOORS SCHEDULE. 2. SEE SHEET A2.2 FOR ELECTRICAL APPLIANCE SCHEDULE. 3. SMOKE ALARM SHALL BE INTERCONNECTED HARD-WIRED WITH BATTERY BACKUP AND SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72. 4. CARBON MONOXIDE ALARM SHALL BE INTERCONNECTED HARD-WIRED WITH BATTERY BACKUP. ATTIC ACCESS: 1. 22"X30" MIN. W/ WEATHER-STRIP OR SEAL TO PREVENT DRAFTS. DOUBLE FRAMING PERPENDICULAR TO ROOF RAFTER TIES'/CEILING JOISTS' SPAN. ROOF PLAN GENERAL NOTES: 1. NOT IN USED. 2. FOR PLUMBING AND/OR DUCTING VENTS, IF APPLICABLE, INSTALL GALVANIZED IRON ROOF JACKS, AS REQUIRED. PROPOSED KEYNOTES N O R T H 3/8" = 1'-0"1 ADU FLOOR PLAN AGING-IN-PLACE REQUIREMENTS A. REINFORCEMENT FOR GRAB BAR INSTALLATION FOR BATHROOMS SHALL BE PROVIDED. (R327.1.1) I. AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BE PROVIDED WITH REINFORCEMENT INSTALLED. IF THERE IS NO BATHROOM ON THE ENTRY LEVEL, AT LEAST ONE ON THE SECOND OR THIRD FLOOR OF THE DWELLING SHALL COMPLY. 1. REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING AGENCY. 2. REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH NOMINAL LUMBER OR OTHER CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD CAPACITY. 3. REINFORCEMENT SHALL BE LOCATED BETWEEN 32 INCHES AND 39¼ INCHES ABOVE FINISHED FLOOR FLUSH WITH THE WALL FRAMING. 4. WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. 5. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. 6. BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS ON EACH END OF THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN 6 INCHES ABOVE THE BATHTUB RIM. B. ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS INTENDED TO BE USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR UNLESS EXCEPTION MET. (R327.1.2) C. INTERIOR DOOR WIDTH (AT LEAST ONE BEDROOM DOOR AND ONE BATHROOM DOOR WITH 32 ” CLEAR OPENING), EFFECTIVE JULY 1, 2024 (R327.1.3) D. DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT EXCEED 48 INCHES ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. WHERE DOORBELL HEIGHT REQUIREMENT CANNOT BE MET FOR INTEGRATED DOORBELL FEATURES, A STANDARD DOORBELL BUTTON OR CONTROL SHALL ALSO BE PROVIDED AT A HEIGHT NOT EXCEEDING 48 INCHES ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON OR CONTROL. REV DATE REMARKS 1 10.03.2024 City Correction 2 06.25.2025 City Correction 2 2 2 2 2 22 2 2 SERVICE LOAD CALCULATION TOTAL GENERAL LOAD :10,454VA DWELLNG INFORMATION: FLOOR AREA : HEATER TYPE : DRYER : OVEN: COOKTOP : 730 SQFT GAS GAS N/A GAS GENERAL LOAD : GENERAL LIGHTING(FLOOR AREA X 3VA/SFT) : SMALL APPLIANCE(2-20ACK BY CEC210.11): LAUNDRY(1-20ACKT BY CEC210.11) : BATHROOM(1-20ACKT BY CEC210.11) : DISHWASHER : MICROWAVE OVEN : GRABAGE DISPOSAL : BATHROOM FANS : GARAGE DOOR OPENER : DRYER : OVEN : REFRIGERATOR : COOKTOP : 2190VA 3000VA 1500VA 0VA 1500VA 0VA 864VA 400VA 0VA 0VA 0VA 1000VA 0VA FIRST 10 KVA AT 100% : REMAINDER AT 40% (454VA X O.4) : SUBTOTAL GENERAL LOAD : 10000VA 182 VA 10,182 VA AIR CONDITIONING KVA CALCULATION : OUTDOOR CONDENSING UNIT : INDOOR FANCOIL UNIT : TOTAL AC LOAD : 4152VA 0VA WATER HEATER : CAR CHARGER : 0VA 0VA PROVIDED SERVICE RATING :100 AMPS CALCULATED LOAD FOR SERVICE : (10,182 VA+4,152 VA+0VA)/240V= 60 A(SERVICE RATING) 4152VA GROUNDING ELECTRODE CONDUCTOR GROUNDING ELECTRODE BOLTED-TYPE CONNECTION DEVICE OR EXOTHERMIC WELD NONMETALLIC PROTECTIVE SLEEVE NO. 4 AWG OR LARGER BARE COPPER CONDUCTOR OR STEEL REINFORCING BAR OR ROD NOT LESS THAN 1/2" IN. DIAMETER 2 IN. MINIMUM CONCRETE FOUNDATION 20 FT MINIMUM 1' - 6 " 3' - 8 " 4' - 0 " 5' - 0 " 6' - 6 " MI N . 7 ' - 6 " FINISHED FLOOR OUTLETS ABOVE THE FLOOR LIGHT SWITCHES OUTLETS ABOVE THE COUNTERTOP THERMOSTAT ELECTRICAL PANEL TO BE MOUNTED AT HIGHEST POINT IN ROOMSD NOTE : COMBINATION SMOKE & CO ALARMS SMOKE ALARM SHALL BE INTERCONNECTED HARDWIRED WITH BATTERY BACKUP AND SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72. CARBON MONOXIDE ALARM BE INTERCONNECTED HARWARD WITH BATTERY BACKUP NOTE : -SMOKE ALARM SHALL BE INSTALLED NOT LESS THAN 3FT HORIZONTALLY FROM THE DOOR OF THE BATHROOM PER 2022 CRC, SECTION R314.3. -SMOKE ALARMS SHALL BE INSTALLED A MINIMUM OF 20FT HORIZONTAL DISTANCE FROM A PERMANENTLY INSTALLED COOKING APPLIANCE OR PLEASE SHOW THAT IONIZATION OR PHOTOELECTRIC SMOKE ALARMS SHALL BE PROVIDED IN ACCORDANCE WITH 2022 CRC, SECTION R314.3.3 ITEM 4 EXCEPTION. NOTE : SCREENS OR OTHER DEVICES THAT OBSTRUCT THE FLOW OF THE EXHAUST DUCT SHALL NOT BE USED AT CLOTHES DRYER EXHAUST DUCTS IN ACCORDANCE WITH 2022 CMC, SECTION 504.4 NOTE : CLOTHES DRYER MOISTURE EXHAUST DUCT MUST BE IN 4-IN. IN DIAMETER AND LENGTH IN LIMITED TO 14-FT. WITH 2 ELBOWS. THE DUCT LENGTH SHALL BE REDUCED BY 2-FT. FOR EVERY ELBOW IN EXCESS OF TWO. NOTE : 1. A RESERVED SINGLE POLE CIRCUIT BREAKER SPACE SHALL BE PROVIDED IN THE ELECTRICAL PANEL ADJACENT TO THE CIRCUIT BREAKER FOR THE BRANCH CIRCUIT AND LABELED WITH THE WORDS "FUTURE 240V USE." PER 2022 CALIFORNIA ENERGY CODE, SECTION 150.0(N)1.A NOTE : GROUNDING ELECTRODE SYSTEM FOR THE NEW SUBPANEL SHALL BE PROVIDED IN ACCORDANCE WITH 2022 CEC, ARTICLE 250.32. NOTE: ADD DOUBLE PROTECTION OUTLET AFCI AND GFCI PER SECTION 210.8A 910 AND 210.12 OF CEC 2022 FOR LAUNDRY AND KITCHEN AREA. NOTE : PANEL LOAD SCHEDULES AND SINGLE LINE DIAGRAMS TO BE PROVIDED DURING INSPECTION. NOTE : PLUMBING INSPECTOR TO VERIFY IF GRIT TRAP FROM PERFORATED PIPE REQUIRED PRIOR TO SS TIE IN. LICENSE PLUMBER TO INCREASE GAS LINE IF REQUIRE VERIFIED FIELD CONDITIONS, BENDS, LENGTH... IN FIELD SD REF. SINK DW TANKLESS WATER HEATER 199,000BTU MINI SPLIT UNIT LIGHT LIGHT 3' - 0 " 3'-0" 3' - 0 " 3' - 0 " EQEQ 3'-0" 3' - 0 " 3' - 0 " 3'-0" EQ EQ GFCI GFCI GF C I GF C I GF C I GF C I GF C I GFCI GFCI GF C I GF C I FAN VACANCY SENSOR FAN 15" SMALL APPLIANCE 20 AMP G.D 20A 42" KITCHEN HOOD 15" 42" 42" 220 WP WPWP 20A 42" VACANCY SENSOR S/CSD AF C I AFCI AFCI AF C I AFCI AF C I AFCI AFCI AFCI AF C I AFCI TV / D A T A DELTA BREEZSLIM 70 CFM WITH HUMIDITY SENSOR CFM EXHAUST BATH FAN, WHITE NOTE : EVERY KITCHEN SHALL HAVE HOOD TO THE OUTSIDE OF THE BUILDING W/ MIN. LESS THAN 750 SF REQUIRES 85% CE OR 280 CFM . 6” DIAM. EQUIPPED WITH BACKDRAFT DAMPER, THAT HAS A MAXIMUM SOUND RATING OF 3-SONES AND THE REQUIREMENT FOR HERS VERIFICATION. P. L . 5 6 . 3 ' NOTE : LUMINAIRES TO BE CONTROLLED BY EITHER DIMMERS OR VACANCY SENSORS IN DINING ROOM AND LIVING ROOM. NOTE : WATER PIPING SHALL MEET THE INSULATION REQUIREMENTS OF 2022 CALIFORNIA ENERGY CODE, SECTION 150.0(J)2.A. ALL DOMESTIC HOT WATER PIPING SHALL BE INSULATED AS SPECIFIED IN SECTION 609.11 OF THE CALIFORNIA PLUMBING CODE. IN ADDITION, THE FOLLOWING PIPING CONDITIONS SHALL HAVE A MINIMUM INSULATION WALL THICKNESS OF 1 INCH OR A MINIMUM INSULATION R-VALUE OF 7.7: I. THE FIRST 5 FEET (1.5 METERS) OF COLD WATER PIPES FROM THE STORAGE TANK. II. ALL HOT WATER PIPING WITH A NOMINAL DIAMETER EQUAL TO OR GREATER THAN 3/4 INCH (19 MILLIMETER) AND LESS THAN 1 INCH. III. ALL HOT WATER PIPING WITH A NOMINAL DIAMETER LESS THAN 3/4 INCH THAT IS: A. ASSOCIATED WITH A DOMESTIC HOT WATER RECIRCULATION SYSTEM; B. FROM THE HEATING SOURCE TO THE KITCHEN FIXTURES; C. FROM THE HEATING SOURCE TO A STORAGE TANK OR BETWEEN STORAGE TANKS; OR D. BURIED BELOW GRADE. GF C I WP3D AFCIAFCI P-SWP WP WP CONTROLLED BY A MANUAL ON AND OFF SWITCH THAT DOES NOT OVERRIDE TO ON THE AUTOMATIC ACTIONS OF ITEMS B) OR C) BELOW; AND B) CONTROLLED BY PHOTOCELL AND MOTION SENSOR. CONTROLS THAT OVERRIDE TO ON SHALL NOT BE ALLOWED UNLESS THE OVERRIDE AUTOMATICALLY REACTIVATES THE MOTION SENSOR WITHIN 6 HOURS; OR CONTROLLED BY ONE OF THE FOLLOWING METHODS: I) PHOTOCONTROL AND AUTOMATIC TIME SWITCH CONTROL. II) ASTRONOMICAL TIME CLOCK. III) ENERGY MANAGEMENT CONTROL SYSTEM. KITCHEN LIVING ROOM MASTER BEDROOM BATH WALK IN CLOSET DINING ROOM MASTER BATH STACK. LAUNDRY BEDROOM #2 CLOSET ENTRY 3' - 0 " EQ EQ 3'-0" 72" GFCIWP (E) AVOCADO TREE (N) WALKWAY (N) CONCRETE PAD 3D 20A MINI SPLIT BLOWER MINI SPLIT BLOWER MINI SPLIT BLOWER MINI SPLIT BLOWER SYMBOLS SINGLE POLE SWITCH SCONCE FIXTURE: UP LIT - LED D= DIMMER V = MANUAL ON, AUTO OFF SCONCE: UP AND DOWN LIT - LED WP = WATER PROOF T = TIMER SWITCH THREE-WAY DIMMER SWITCH FLUORESCENT FIXTURE SINGLE OUTLET EXHAUST FAN w/100 CFM MIN. FAN w/100 CFM MIN. EXTERIOR LIGHT V = W/ MANUAL ON, AUTO OFF H = W/ AUTO ON HUMIDISTAT SENSOR DUPLEX OUTLET EXHAUST FAN w/50 CFM MIN. WP = WATER PROOF V = MANUAL ON, AUTO OFF GFCI = GROUND FAULT CIRCUIT INTER. H = W/ AUTO ON HUMIDISTAT SENSOR AFCI = ARC FAULT CIRCUIT INTER. USB QUADROPOLE OUTLET SURFACE MOUNTED FIXTURES M = MOTION SENSOR P = MOTION SENSOR W/ PHOTO SENSE E = HIGH EFFICIENCY WALL MOUNTED LAMP LV = LOW VOLTAGE MOTION SENSOR/PHOTOCELL. SPEAKER 220V OUTLET RECESSED FIXTURE-LED R = RANGE OUTLET D = CLOTHES DRYER OUTLET H = RADIANT HEATER H3 WALL MOUNTED FIXTURE - LED SPECIAL-PURPOSE OUTLET HOME SECURITY PANEL DW = DISHWASHER OUTLET GD = GARBAGE DISPOSAL S = STEAM SHOWER SMOKE DETECTOR CARBON MONOXIDE DETECTOR CLOCK OUTLET SMOKE & CARBON MONOXIDE DETECTOR EXIT LIGHT OUTLET HOSE BIB DATA OUTLET 1.SWITCHES TO BE 42" ABV. FF UON T = TELEPHONE 2. OUTLETS TO BE 15" ABV. FF UON TV = TELEVISION 3. OUTLETS ABV. COUNTER TOPS TO BE EN = ETHERNET 42" ADV. FF UON M = MULTI (TELE./TV/EN) J BOX COVE LIGHTING CAMERA DIFFUSER RECESSED LINEAR LIGHT VACANCY SENSOR CL . C SD S HB 3D W PP - S S/C R 0 1'-4"2'-8"5'-4" SCALE: 3/8" = 1'-0" DATE: P.M.: DRAWN BY: JOB NO.: 26081 Merit Cir, STE 111 Laguna Hills, CA 92653 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D ES I GNBUILDCNI 7/ 2 / 2 0 2 5 1 0 : 2 9 : 2 2 A M A2.3 B.N. F.M. ELECTRICAL PLAN 07.11.24 2024001108 UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT 3" = 1'-0"2 GROUNDING ELECTRODE 3/8" = 1'-0"1 ELECTRICAL PLAN 1. FRIDGE (20 AMP) 2. COOKTOP/RANGE (20 AMP, 120/240V) 3. RANGE HOOD (15-20 AMP) 4. COUNTERTOP RECEPTACLES (2 CIRCUITS, 20 AMP) 5. KITCHEN LIGHTING (15-20 AMP) 6. EACH ROOM/HALLWAY SHALL HAVE SEPARATE CIRCUITS FOR LIGHTS AND RECEPTACLES (20 AMP) 7. WALL MOUNTED AIR CONDITIONERS (20 AMP EACH) 8. BATHROOM RECEPTACLES AND LIGHTS (20 AMP) 9. BATHROOM FAN (20 AMP) 10. DINING ROOM: SEPARATE (20 AMP) CIRCUIT FOR ENTERTAINMENT CENTER 11. WASHER AND DRYER (GAS: 20 AMP OR ELECTRIC: 30 AMP) FIXTURE MOUNTING HEIGHTS 1. WHOLE BUILDING VENTILATION PER ASHRAE STANDARD 62.2, SOLUTION: EXHAUST VENTILATION THROUGH BATHROOM FAN(S). 2. THE BATH FAN(S) RUNS INTERMITTENTLY ON A TIMER (100 CFM EVERY 4 HOURS FOR 1 HOUR, WITH MANUAL OVERRIDE) AND WHILE IT IS RUNNING, FRESH AIR SHALL BE PULLED FROM THE OUTSIDE. HEATING AND COOLING: 1. INSTALL MINI SPLIT OUTDOOR COMPRESSOR AND INDOOR WALL UNITS. 2. UNITS LOCATION PER ELECTRICAL PLAN. 3. INSTALLATION, PIPING AND CLEARANCES ACCORDING TO MANUFACTURER'S RECOMMENDATIONS ELECTRICAL SYSTEM TO BEELECTRICAL SYSTEM TO BE INSTALLED WITH SEPARATECIRCUITS FOR:INSTALLED WITH SEPARATECIRCUITS FOR: METHOD OF VENTILATION:METHOD OF VENTILATION: NOTE : WATER PIPING SHALL MEET THE INSULATION REQUIREMENTS OF 2022 CALIFORNIA ENERGY CODE, SECTION 150.0(J)2.A. ALL DOMESTIC HOT WATER PIPING SHALL BE INSULATED AS SPECIFIED IN SECTION 609.11 OF THE CALIFORNIA PLUMBING CODE. IN ADDITION, THE FOLLOWING PIPING CONDITIONS SHALL HAVE A MINIMUM INSULATION WALL THICKNESS OF 1 INCH OR A MINIMUM INSULATION R-VALUE OF 7.7: I. THE FIRST 5 FEET (1.5 METERS) OF COLD WATER PIPES FROM THE STORAGE TANK. II. ALL HOT WATER PIPING WITH A NOMINAL DIAMETER EQUAL TO OR GREATER THAN 3/4 INCH (19 MILLIMETER) AND LESS THAN 1 INCH. III. ALL HOT WATER PIPING WITH A NOMINAL DIAMETER LESS THAN 3/4 INCH THAT IS: A. ASSOCIATED WITH A DOMESTIC HOT WATER RECIRCULATION SYSTEM; B. FROM THE HEATING SOURCE TO THE KITCHEN FIXTURES; C. FROM THE HEATING SOURCE TO A STORAGE TANK OR BETWEEN STORAGE TANKS; OR D. BURIED BELOW GRADE. NOTE : PLUMBING INSPECTOR TO VERIFY IF GRIT TRAP FROM PERFORATED PIPE REQUIRED PRIOR TO SS TIE IN. LICENSE PLUMBER TO INCREASE GAS LINE IF REQUIRE VERIFIED FIELD CONDITIONS, BENDS, LENGTH... IN FIELD GENERAL ELECTRICAL NOTES FOR NEW DETACHED RESIDENTIAL 1. WATER HEATING SYSTEM (WATER HEATER) – (SECTION 150.0(N)) A. SYSTEMS USING GAS OR PROPANE WATER HEATERS TO SERVE INDIVIDUAL DWELLING UNITS SHALL DESIGNATE A SPACE AT LEAST 2.5 FEET BY 2.5 FEET WIDE AND 7 FEET TALL SUITABLE FOR THE FUTURE INSTALLATION OF A HEAT PUMP WATER HEATER (HPWH) BY MEETING EITHER A OR B LISTED UNDER SECTION 150.0(N). I. IF THE DESIGNATED SPACE IS WITHIN 3 FEET FROM THE WATER HEATER: A. A DEDICATED 125 VOLT, 20 AMP ELECTRICAL RECEPTACLE THAT IS CONNECTED TO THE ELECTRIC PANEL WITH A 120/240 VOLT 3 CONDUCTOR, 10 AWG COPPER BRANCH CIRCUIT, WITHIN 3 FEET FROM THE WATER HEATER. II. ISOLATE BOTH ENDS OF THE UNUSED CONDUCTOR. B. A RESERVED SINGLE POLE CIRCUIT BREAKER SPACE IN THE ELECTRICAL PANEL ADJACENT TO THE CIRCUIT BREAKER C. A CONDENSATE DRAIN THAT ALLOWS NATURAL DRAINING OF THE WATER HEATER. D. . IF THE DESIGNATED SPACE IS MORE THAN 3 FEET FROM THE WATER HEATER: SEE ADDITIONAL CODE REQUIREMENTS. B. WHEN A SECOND WATER HEATER IS INSTALLED AS PART OF THE ADDITION SHALL COMPLY WITH SECTION (150.2(A)(D). ENERGY STORAGE SYSTEM (ESS) READY: ALL SINGLE-FAMILY RESIDENCES THAT INCLUDE ONE OR TWO DWELLING UNITS, AND ADU SHALL MEET THE FOLLOWING: A. AT LEAST ONE OF THE FOLLOWING SHALL BE PROVIDED: I. ESS READY INTERCONNECTION EQUIPMENT [AUTO TRANSFER SWITCH AND PANEL] WITH A MINIMUM BACKED-UP CAPACITY OF 60 AMPS AND A MINIMUM OF FOUR ESS-SUPPLIED BRANCH CIRCUITS, OR II. A DEDICATED, MINIMUM 1” RACEWAY FROM THE MAIN SERVICE TO A SUBPANEL THAT SUPPLIES THE BRANCH CIRCUITS IN SECTION 150.0(S)(2). B. A MINIMUM OF FOUR BRANCH CIRCUITS SHALL BE SUPPLIED BY THE ESS: THE REFRIGERATOR, ONE LIGHTING CIRCUIT SHALL BE LOCATED NEAR THE PRIMARY EGRESS, AND AT LEAST ONE CIRCUIT SHALL SUPPLY A SLEEPING ROOM RECEPTACLE OUTLET. C. THE MAIN PANELBOARD SHALL HAVE A MINIMUM BUSBAR RATING OF 225 AMPERES WITH SPACE TO INSTALL FUTURE ISOLATION EQUIPMENT/TRANSFER SWITCH WITHIN 3 FEET. HEAT PUMP SPACE HEATER (FURNACE) READY: SYSTEM USING GAS FURNACE TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE A DEDICATED 240 VOLT, MINIMUM 30 AMPS BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3- FT FROM THE FURNACE FOR A FUTURE HEAT PUMP SPACE HEATER INSTALLATION. ELECTRIC COOKTOP READY: SYSTEM USING GAS TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE A DEDICATED 240 VOLT, MINIMUM 50 AMPS CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3-FT FROM THE COOKTOP FOR A FUTURE ELECTRIC COOKTOP INSTALLATION. ELECTRIC CLOTHES DRYER READY: CLOTHES DRYER USING GAS TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE A DEDICATED 240 VOLT, MINIMUM 30 AMPS BRANCH CIRCUIT WIRING SHALL BE INSTALLED 3-FT FROM THE CLOTHES DRYER LOCATION FOR A FUTURE ELECTRIC CLOTHES DRYER INSTALLATION. REV DATE REMARKS 2 06.25.2025 City Correction 2 2 22 FINISH GROUND0' - 0" EXISTING HOUSE RIDGE15' - 0" ADU FINISH FLOOR0' - 6" CEILING8' - 6" ADU RIDGE13' - 1" PR O P E R T Y L I N E WALL SEPARATION 15'-0" REAR SETBACK 5'-0" EXISTING HOUSE 01010303 02 VI F 3' - 0 " VI F 3' - 0 " VI F 4' - 0 " 2.58 2.43 2.46SAFETY GLAZING SAFETY GLAZING SAFETY GLAZING SAFETY GLAZING SAFETY GLAZING SAFETY GLAZING 01 2.46 2.46 ALL NEW WINDOWS WILL BE MULTI-LITE WINDOWS. ALL NEW EXTERIOR DOORS SHALL BE FRENCH MULTI-LITE DOORS. 4" WOOD SIDING MATCH EXISTING 2' - 0 " 2' - 0 " 5 1/2" 2" 3 1 / 2 " OVERHANG 1'-0"OVERHANG 1'-0" SETBACK 4'-0" WALL SEPARATION 3'-0" THE EAVES HAVE DECORATIVE GUTTER, SIMILAR TO THE MAIN UNIT WALL VENT 15 ' - 0 " 13 ' - 1 " WALL SEPARATION 5'-0" 2.19 2.84 2.84 4" / 1'-0"4" / 1'-0" 4" FINISH GROUND 0' - 0" EXISTING HOUSE RIDGE15' - 0" ADU FINISH FLOOR0' - 6" CEILING8' - 6" ADU RIDGE13' - 1" EXISTING HOUSE EXISTING GARAGE 4" / 1'-0" 4" / 1'-0" PR O P E R T Y L I N E WALL SEPARATION 5'-0" DETACHED ADU 31'-0" REAR SETBACK 5'-0" 4" WOOD SIDING MATCH EXISTING EGRESS SAFETY GLAZING EGRESSEGRESSEGRESS 2.58 2.46 2.842.84 2.46 01 01 01 01 02 2' - 0 " VI F 3' - 0 " OVERHANG 1'-0"OVERHANG 1'-0" 5 1/2" 2" 3 1 / 2 " 2' - 0 " VI F 3' - 0 " SETBACK 4'-0" WALL SEPARATION 3'-0" THE EAVES HAVE DECORATIVE GUTTER, SIMILAR TO THE MAIN UNIT 4" WALL VENT 15 ' - 0 " 13 ' - 1 " DATE: P.M.: DRAWN BY: JOB NO.: 26081 Merit Cir, STE 111 Laguna Hills, CA 92653 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D ES I GNBUILDCNI 7/ 2 / 2 0 2 5 1 0 : 2 9 : 3 2 A M A3.0 B.N. F.M. NORTH AND SOUTH ELEVATIONS 07.11.24 2024001108 UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT 0 1'-4"2'-8"5'-4" SCALE: 3/8" = 1'-0" 3/8" = 1'-0"1 NORTH ELEVATION 3/8" = 1'-0"2 SOUTH ELEVATION NOTE: ALL BUILDING MATERIALS AND COLORS TO MATCH EXISTING. WINDOWS ON THE ADU SHALL MATCH THE EXISTING WINDOWS IN STYLE, TREM, AND METHOD OF OPERATION 1. THE ADU SHALL RESEMBLE THE PRIMARY HOME IN TERMS OF STYLE, INCLUDING, BUT NOT LIMITED TO MATERIALS, COLORS AND SHAPE OF WALLS, ROOF, DOORS, WINDOWS AND TRIMS. 2. SEE SHEET A5.0 FOR DETAILS OF ALL EXTERIOR LIGHTS, ELECTRICAL APPLIANCES AND OUTLETS. ROOFING: 1. ASPHALT SHINGLES, COLOR TO MATCH THE MAIN HOUSE. THE EXACT COLOR SELECTION TO BE CONFIRMED WITH PROJECT CONTACT DURING CONSTRUCTION. 2. DOUBLE LAYER OF UNDERLAYMENT IS REQUIRED FOR 2-4 ”/12” ROOF. 3. ROOF GUTTERS SHALL BE PROVIDED WITH THE MEANS TO PREVENT THE ACCUMULATION OF LEAVES AND DEBRIS IN THE GUTTER. FASCIA, GUTTER, DOWNSPOUTS: 1. 1x FASCIA AND GUTTER COLOR TO MATCH THE MAIN HOUSE. THE EXACT COLOR SELECTION TO BE CONFIRMED WITH PROJECT CONTACT DURING CONSTRUCTION. 2. USE DIA 5" GUTTER AND DOWNSPOUTS, 26 GA. GALV. AS REQUIRED. 3. INSTALL CONCRETE SPLASH BLOCKS AT DOWNSPOUT LOCATIONS FOR DRAINAGE AWAY FROM STRUCTURE. FLASHING AT ROOF TO WALL, ROOF VALLEY & RIDGE CONNECTIONS, ROOF PENETRATIONS: 1. USE 26 GA. GALV. FLASHING/DRIP EDGE/ WEEP SCREED AT THE CONNECTION WALL TO FOUNDATION: 1. USE 26 GA. GALV. EXTERIOR WALLS: 1. EXTERIOR FINISH: WOOD SIDING ON MESH TO MATCH THE MAIN HOUSE. THE EXACT COLOR SELECTION TO BE CONFIRMED WITH PROJECT CONTACT DURING CONSTRUCTION. DOOR AND WINDOW TRIMS: 1. COLOR TO MATCH THE MAIN HOUSE. THE EXACT COLOR SELECTION TO BE CONFIRMED WITH PROJECT CONTACT DURING CONSTRUCTION. MINI SPLIT OUTDOOR INSTALLATION: 1. PROVIDE A PAD UNDER THE COMPRESSOR. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR SIZE, THICKNESS AND INSTALLATION INSTRUCTIONS. REV DATE REMARKS 1 10.03.2024 City Correction 2 06.25.2025 City Correction 2 2 2 FINISH GROUND0' - 0" EXISTING HOUSE RIDGE15' - 0" 4" / 1'-0" 4" / 1'-0" PR O P E R T Y L I N E PR O P E R T Y L I N E SIDE SETBACK 25'-3" ADU 25'-9 1/2" SIDE SETBACK 5'-0" ADU FINISH FLOOR 0' - 6" CEILING8' - 6" ADU RIDGE 13' - 1" OVERHANG 1'-0"OVERHANG 1'-0" SETBACK 4'-0" SETBACK 24'-3" 01 2.19 2.58 2.84 2.84 2.84 VI F 3' - 0 " TANKLESS WATER HEATER 199,000BTU MINI SPLIT ELECTRICAL SUB PANEL 100A SAFETY GLAZING 2.462.46 ALL NEW WINDOWS WILL BE MULTI-LITE WINDOWS. ALL NEW EXTERIOR DOORS SHALL BE FRENCH MULTI-LITE DOORS. 4" WOOD SIDING MATCH EXISTING 2' - 0 " THE EAVES HAVE DECORATIVE GUTTER, SIMILAR TO THE MAIN UNIT WALL VENT 4" ENCLOSURE OF WATER HEATER FINISH GROUND 0' - 0" EXISTING HOUSE RIDGE15' - 0" PR O P E R T Y L I N E PR O P E R T Y L I N E SIDE SETBACK 25'-3" DETACHED ADU 25'-9 1/2" SIDE SETBACK 5'-0" ADU FINISH FLOOR0' - 6" CEILING8' - 6" ADU RIDGE13' - 1" EXISTING HOUSE BEYOND OVERHANG 1'-0"OVERHANG 1'-0" SETBACK 4'-0" SETBACK 24'-3" 4" WOOD SIDING MATCH EXISTING 2.46 2.842.84 2.46 THE EAVES HAVE DECORATIVE GUTTER, SIMILAR TO THE MAIN UNIT 15 ' - 0 " 13 ' - 1 " 4" 2.84 DATE: P.M.: DRAWN BY: JOB NO.: 26081 Merit Cir, STE 111 Laguna Hills, CA 92653 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D ES I GNBUILDCNI 7/ 2 / 2 0 2 5 1 0 : 2 9 : 4 2 A M A3.1 B.N. F.M. EAST AND WEST ELEVATIONS 07.11.24 2024001108 UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT 0 1'-4"2'-8"5'-4" SCALE: 3/8" = 1'-0" 3/8" = 1'-0"1 EAST ELEVATION 3/8" = 1'-0"2 WEST ELEVATION NOTE: ALL BUILDING MATERIALS AND COLORS TO MATCH EXISTING. WINDOWS ON THE ADU SHALL MATCH THE EXISTING WINDOWS IN STYLE, TREM, AND METHOD OF OPERATION 1. THE ADU SHALL RESEMBLE THE PRIMARY HOME IN TERMS OF STYLE, INCLUDING, BUT NOT LIMITED TO MATERIALS, COLORS AND SHAPE OF WALLS, ROOF, DOORS, WINDOWS AND TRIMS. 2. SEE SHEET A5.0 FOR DETAILS OF ALL EXTERIOR LIGHTS, ELECTRICAL APPLIANCES AND OUTLETS. ROOFING: 1. ASPHALT SHINGLES, COLOR TO MATCH THE MAIN HOUSE. THE EXACT COLOR SELECTION TO BE CONFIRMED WITH PROJECT CONTACT DURING CONSTRUCTION. 2. DOUBLE LAYER OF UNDERLAYMENT IS REQUIRED FOR 2-4 ”/12” ROOF. 3. ROOF GUTTERS SHALL BE PROVIDED WITH THE MEANS TO PREVENT THE ACCUMULATION OF LEAVES AND DEBRIS IN THE GUTTER. FASCIA, GUTTER, DOWNSPOUTS: 1. 1x FASCIA AND GUTTER COLOR TO MATCH THE MAIN HOUSE. THE EXACT COLOR SELECTION TO BE CONFIRMED WITH PROJECT CONTACT DURING CONSTRUCTION. 2. USE DIA 5" GUTTER AND DOWNSPOUTS, 26 GA. GALV. AS REQUIRED. 3. INSTALL CONCRETE SPLASH BLOCKS AT DOWNSPOUT LOCATIONS FOR DRAINAGE AWAY FROM STRUCTURE. FLASHING AT ROOF TO WALL, ROOF VALLEY & RIDGE CONNECTIONS, ROOF PENETRATIONS: 1. USE 26 GA. GALV. FLASHING/DRIP EDGE/ WEEP SCREED AT THE CONNECTION WALL TO FOUNDATION: 1. USE 26 GA. GALV. EXTERIOR WALLS: 1. EXTERIOR FINISH: WOOD SIDING ON MESH TO MATCH THE MAIN HOUSE. THE EXACT COLOR SELECTION TO BE CONFIRMED WITH PROJECT CONTACT DURING CONSTRUCTION. DOOR AND WINDOW TRIMS: 1. COLOR TO MATCH THE MAIN HOUSE. THE EXACT COLOR SELECTION TO BE CONFIRMED WITH PROJECT CONTACT DURING CONSTRUCTION. MINI SPLIT OUTDOOR INSTALLATION: 1. PROVIDE A PAD UNDER THE COMPRESSOR. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR SIZE, THICKNESS AND INSTALLATION INSTRUCTIONS. REV DATE REMARKS 1 10.03.2024 City Correction 2 06.25.2025 City Correction 2 FINISH GROUND0' - 0" ADU FINISH FLOOR0' - 6" CEILING 8' - 6" ADU RIDGE13' - 1" PR O P E R T Y L I N E PR O P E R T Y L I N E ATTIC SPACE R-30 LAUNDRY R-30 8' - 0 " WALK IN CLOSET 8' - 0 " VI F 3' - 0 1 / 2 " R-15 A5.0 5 A5.0 4 A5.0 3 03 A5.0 14 A5.0 13 2'-0" 1'-0"1'-0" SETBACK 5'-0"SETBACK 25'-3" SETBACK 4'-0" 4" / 1'-0"4" / 1'-0" FINISH GROUND0' - 0" ROOF EAVE 9' - 7" ADU FINISH FLOOR 0' - 6" CEILING 8' - 6" ADU RIDGE13' - 1" ATTIC SPACE VI F 3' - 2 " VI F 1' - 8 " PR O P E R T Y L I N E REAR SETBACK 5'-0" SETBACK 4'-0" 4" / 1'-0"4" / 1'-0" ENCLOSURE OF WATER HEATER R-30 R-15 R-30 8' - 0 " 8' - 0 " 060103 1'-0" A5.0 5 A5.0 3 A5.0 13 A5.0 4 A5.0 11 A5.0 9 DATE: P.M.: DRAWN BY: JOB NO.: 26081 Merit Cir, STE 111 Laguna Hills, CA 92653 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D ES I GNBUILDCNI 7/ 2 / 2 0 2 5 1 0 : 2 9 : 4 3 A M A3.2 B.N. F.M. SECTION 07.11.24 2024001108 UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT 0 1'-4"2'-8"5'-4" SCALE: 3/8" = 1'-0" 3/8" = 1'-0"1 SECTION A-A NOTE: ALL BUILDING MATERIALS AND COLORS TO MATCH EXISTING. WINDOWS ON THE ADU SHALL MATCH THE EXISTING WINDOWS IN STYLE, TREM, AND METHOD OF OPERATION 1. THE ADU SHALL RESEMBLE THE PRIMARY HOME IN TERMS OF STYLE, INCLUDING, BUT NOT LIMITED TO MATERIALS, COLORS AND SHAPE OF WALLS, ROOF, DOORS, WINDOWS AND TRIMS. 2. SEE SHEET A5.0 FOR DETAILS OF ALL EXTERIOR LIGHTS, ELECTRICAL APPLIANCES AND OUTLETS. ROOFING: 1. ASPHALT SHINGLES, COLOR TO MATCH THE MAIN HOUSE. THE EXACT COLOR SELECTION TO BE CONFIRMED WITH PROJECT CONTACT DURING CONSTRUCTION. 2. DOUBLE LAYER OF UNDERLAYMENT IS REQUIRED FOR 2-4 ”/12” ROOF. 3. ROOF GUTTERS SHALL BE PROVIDED WITH THE MEANS TO PREVENT THE ACCUMULATION OF LEAVES AND DEBRIS IN THE GUTTER. FASCIA, GUTTER, DOWNSPOUTS: 1. 1x FASCIA AND GUTTER COLOR TO MATCH THE MAIN HOUSE. THE EXACT COLOR SELECTION TO BE CONFIRMED WITH PROJECT CONTACT DURING CONSTRUCTION. 2. USE DIA 5" GUTTER AND DOWNSPOUTS, 26 GA. GALV. AS REQUIRED. 3. INSTALL CONCRETE SPLASH BLOCKS AT DOWNSPOUT LOCATIONS FOR DRAINAGE AWAY FROM STRUCTURE. FLASHING AT ROOF TO WALL, ROOF VALLEY & RIDGE CONNECTIONS, ROOF PENETRATIONS: 1. USE 26 GA. GALV. FLASHING/DRIP EDGE/ WEEP SCREED AT THE CONNECTION WALL TO FOUNDATION: 1. USE 26 GA. GALV. EXTERIOR WALLS: 1. EXTERIOR FINISH: WOOD SIDING ON MESH TO MATCH THE MAIN HOUSE. THE EXACT COLOR SELECTION TO BE CONFIRMED WITH PROJECT CONTACT DURING CONSTRUCTION. DOOR AND WINDOW TRIMS: 1. COLOR TO MATCH THE MAIN HOUSE. THE EXACT COLOR SELECTION TO BE CONFIRMED WITH PROJECT CONTACT DURING CONSTRUCTION. MINI SPLIT OUTDOOR INSTALLATION: 1. PROVIDE A PAD UNDER THE COMPRESSOR. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR SIZE, THICKNESS AND INSTALLATION INSTRUCTIONS. ELEVATIONS GENERAL NOTESELEVATIONS GENERAL NOTES REV DATE REMARKS 3/8" = 1'-0"2 SECTION B-B - 03 - INTERIOR SWING DOOR SE E S C H E D U L E SEE SCHEDULE SAFETY GLAZING - 01 - EXTERIOR SINGLE MULTI-LITE FRENCH DOOR SE E S C H E D U L E SEE SCHEDULE - 04 - INTERIOR LOUVER DOOR (MIN. OPENING OF 100SF) SE E S C H E D U L E SEE SCHEDULE - 05 - INTERIOR SWING DOOR SE E S C H E D U L E SEE SCHEDULE - 06 - INTERIOR POCKET DOOR SE E S C H E D U L E SEE SCHEDULE - 07- INTERIOR CLOSET DOOR SE E S C H E D U L E SEE SCHEDULE - 02- INTERIOR CLOSET DOOR SE E S C H E D U L E SEE SCHEDULE MINIMUM SIZE WINDOW FOR 24" CLEAR WIDTH MINIMUM SIZE WINDOW FOR 24" CLEAR HEIGHT FINISH FLOOR EGRESS WINDOW REQUIREMENTS PER CRC. SECTION 1029 OPENABLE AREA = MIN. 5.7 SF NET AREA 2' - 0" 3' - 5 " 3' - 8 " 2' - 10" 2' - 0 " 3' - 8 " CLRCLR CL R CL R MA X MA X FLOOR SLAB ON GRADE VINYL PLANKS UNDERLAYMENT CAST-IN-PLACE CONCRETE NOTES: 1. IN BATHROOMS USE CERAMIC TILE IN PLACE OF VINYL CEILING TYPICAL WOOD FRAMING, INSULATED GYPSUM WALL BOARD 1/2" EXTERIOR WALL TYPICAL 2x4EWP4 HOUSE WRAP SIDING ON MESH PLYWOOD, SHEATHING GRADE 5/8" WOOD FRAMING, INSULATED GYPSUM WALL BOARD 1/2" NOTES: 1. INSULATION: MIN. R-15, MINERAL WOOL OR FIBERGLASS ROOF ASPHALT SHINGLE WOOD FRAMING PLYWOOD, SHEATHING GRADE 5/8" UNDERLAYMENT ASPHALT ROOFING SHINGLE INTERIOR WALL TYPICAL IW4 GYPSUM WALL BOARD 1/2" WOOD FRAMING GYPSUM WALL BOARD 1/2" NOTES: 1. IN BATHROOMS USE WATERPROOF CEMENT BACKER BOARDS OR GREENBOARDS. 2. USE CEMENT BACKER BOARDS IN WALL AREAS IN DIRECT CONTACT WITH WATER. INTERIOR WALL TYPICAL IW6 GYPSUM WALL BOARD 1/2" WOOD FRAMING GYPSUM WALL BOARD 1/2" NOTES: 1. IN BATHROOMS USE WATERPROOF CEMENT BACKER BOARDS OR GREENBOARDS. 2. USE CEMENT BACKER BOARDS IN WALL AREAS IN DIRECT CONTACT WITH WATER. EXTERIOR SINGLE-HUNG WINDOW -01- EGRESS VI F 3' - 0 " 2' - 0 " SE E S C H E D U L E SEE SCHEDULE 5 1/2" 2" 3 1 / 2 " EXTERIOR SINGLE-HUNG WINDOW -02- SAFETY GLAZING VI F 4' - 0 " SE E S C H E D U L E SEE SCHEDULE 5 1/2" 2" 3 1 / 2 " EXTERIOR SINGLE-HUNG WINDOW -03- VI F 3' - 0 " 2' - 0 " SE E S C H E D U L E SEE SCHEDULE 5 1/2" 2" 3 1 / 2 " SAFETY GLAZING24" MIN. OPENING DATE: P.M.: DRAWN BY: JOB NO.: 26081 Merit Cir, STE 111 Laguna Hills, CA 92653 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D ES I GNBUILDCNI 7/ 2 / 2 0 2 5 1 1 : 1 8 : 2 1 A M A4.0 B.N. F.M. WINDOW & DOOR SCHED., TYPES,& NOTES 07.11.24 2024001108 UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT DOOR NUMBER NAME. TYPE DOOR DIMENSION DOOR MATERIAL & FINISH FRAME MATERIAL & FINISH HARDWARE HARDWARE W H T MATERIAL FINISH GLASS FINISH MATERIAL FINISH EX I T D E V I C E FI R E - R A T E D 01 FRENCH Door 3' - 0"7' - 0"2"WOOD AND GLASS FF CLEAR FF U - FACTOR 0.3, SHGC 0.23 02 CLOSET Door 4' - 0"6' - 8"1 3/4"WOOD FF FF 04 LOUVER Door 2' - 8"6' - 8"1 3/4"WOOD FF FF 05 SWING Door 2' - 8"6' - 8"1 3/4"WOOD FF FF 06 POCKET Door 2' - 4"6' - 8"1 3/4"WOOD FF FF 07 CLOSET Door 7' - 0"6' - 8"1 3/4"WOOD FF FF DOOR TYPES DOOR SCHEDULEDOOR SCHEDULE 1. ALL MOUNTING ACCESSORIES SHALL BE PROVIDED ACCORDING TO MANUFACTURER'S REQUIREMENTS. AND MUST COMPLY WITH CBC 1010.1.9 2. DOORS/WINDOWS MANUFACTURER, MODEL AND DETAILS ARE FOR DESIGN PURPOSES AND SHALL BE VERIFIED WITH THE PROJECT CONTACT. 3. DURING CONSTRUCTION AND INSTALLATION ANY DOORS AND WINDOWS CAN BE REPLACED WITH EQUIVALENT BRAND AND MODEL PROVIDED IT MEETS ALL THE REQUIREMENTS FOR: A. ENERGY PERFORMANCE; B. EGRESS (IF APPLICABLE); C. TEMPERED GLAZING (IF APPLICABLE); D. SIZE (GLAZED AREA FOR NATURAL LIGHT ACCESS); E. DOES NOT IMPACT THE STRUCTURAL PLAN. 4. PROJECT CONTACT AND/OR THEIR LICENSED CONTRACTOR TO VERIFY MANUFACTURER'S RECOMMENDATIONS FOR, BUT NOT LIMITED TO, ROUGH OPENING SIZES AND INSTALLATION PRIOR TO COMMENCING THE FRAMING. 5. PROJECT CONTACT AND/OR THEIR LICENSED CONTRACTOR TO VERIFY ALL WINDOW DIMENSIONS, MODELS, ROUGH OPENINGS IN THE FRAMING DURING CONSTRUCTION AND TEMPERED GLAZING REQUIREMENTS PRIOR TO ORDERING DOORS AND WINDOWS FOR THE PROJECT. 6. ALL DOORS AND WINDOWS SHALL BE INSTALLED AND WATERPROOFED ACCORDING TO THESE PLANS AND MANUFACTURER'S RECOMMENDATIONS. 7. ALL WINDOWS AND DOORS WITH GLAZING SHALL HAVE THE CERTIFYING LABEL ATTACHED, SHOWING U-VALUE. THE LABEL SHALL BE NOT REMOVED UNTIL THE FINAL INSPECTION. EMERGENCY ESCAPE (EGRESS) WINDOWS (CBC 1030 and CRC R310.1) 1. AT LEAST ONE WINDOW IN EACH BEDROOM IS REQUIRED TO MEET THESE REQUIREMENTS: A. MINIMUM NET 5.7 SQFT OF OPENABLE AREA; B. MINIMUM NET 20" CLEAR WIDTH WHEN OPEN; C. MINIMUM NET 24": CLEAR HEIGHT WHEN OPEN; D. MAXIMUM HEIGHT OF 44" FROM THE FINISHED FLOOR TO THE BOTTOM OF THE CLEAR OPENING; TEMPERED GLAZING REQUIREMENTS (CBC 2406 and CRC 308.1, R308.4) 1. ALL DOORS WITH GLAZING SHALL BE OF TEMPERED GLAZING. 2. WINDOW GLAZING REQUIREMENTS ARE INDICATED ON THE FLOOR PLAN SHEET A2.0. 3. PROJECT CONTACT AND/OR THEIR LICENSED CONTRACTOR TO VERIFY TEMPERED GLAZING REQUIREMENTS PRIOR TO WINDOW ORDERING AND INSTALLATION, SEE THE REQUIREMENTS BELOW. 4. TEMPERED GLAZING SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: A. WITHIN A 2’ ARC OF EITHER THE EDGE OF A DOOR AND WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60” ABOVE THE WALKING SURFACE. B. ADJACENT TO A BOTTOM STAIR LANDING WHERE GLAZING IS LESS THAN 36 INCHES ABOVE THE LANDING AND WITHIN 60 INCHES HORIZONTALLY OF THE LANDING. C. ADJACENT TO STAIRS WHERE GLAZING IS LOCATED LESS THAN 36 INCHES ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE. D. WITHIN A PORTION OF WALL ENCLOSING A TUB/SHOWER WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES ABOVE THE STANDING SURFACE AND DRAIN INLET. E. WITHIN 60 INCHES OF A TUB/SHOWER WHERE THE GLAZING IS LESS THAN 60 INCHES ABOVE THE WALKING SURFACE. F. ANY GLAZING MEETING ALL THE FOLLOWING CONDITIONS: A. EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET B. EXPOSED BOTTOM EDGE IS LESS THAN 18 INCHES ABOVE THE FINISHED FLOOR C. EXPOSED TOP EDGE IS GREATER THAN 36 INCHES ABOVE THE FINISHED FLOOR D. WHERE A WALKING SURFACE IS WITHIN 36 INCHES HORIZONTALLY OF THE GLAZING 5. WHERE REQUIRED, TEMPERED GLAZING (EXCEPT TEMPERED SPANDREL GLASS) SHALL BE PERMANENTLY IDENTIFIED BY A MANUFACTURER MARKING THAT IS PERMANENTLY APPLIED AND CANNOT BE REMOVED WITHOUT BEING DESTROYED (E.G. SAND BLASTED, ACID ETCHED, CERAMIC FIRED, LASER ETCHED, OR EMBOSSED). A LABEL SHALL BE PERMITTED IN LIEU OF THE MANUFACTURER ’ S DESIGNATION. 1. USE 5⁄8" GYPSUM BOARD THROUGHOUT THE BUILDING. 2. DRYWALL (SHEETROCK) IS THE INTERIOR FINISH MOST COMMONLY USED IN RESIDENTIAL CONSTRUCTION. THE FOLLOWING GUIDELINES PERTAIN TO ITS APPLICATION. SAME APPLIES TO WATERPROOF CEMENT WALL BOARDS. 3. WALLBOARD SHALL NOT BE INSTALLED UNTIL WEATHER PROTECTION FOR THE INSTALLATION IS PROVIDED. 4. WHEN PRACTICAL, WALLBOARD SHOULD BE APPLIED FIRST TO THE CEILINGS, AND THEN TO WALLS. SHEETS SHOULD BE BROUGHT INTO CONTACT BUT NOT FORCED INTO PLACE. SPACES BETWEEN SHEETS SHOULD NOT EXCEED 1/4" AND TAPERED EDGES SHOULD BE PLACED NEXT TO EACH OTHER WHEREVER POSSIBLE. 5. CUTOUTS FOR ELECTRICAL OUTLETS, PIPES, FIXTURES OR OTHER SMALL OPENINGS SHOULD BE CUT OUT NEATLY WITH A MAXIMUM CLEARANCE OF 1/4". IF THERE ARE ANY GAPS EXCEEDING 1/4", THEY MUST BE FILLED WITH TAPING COMPOUND AND DRYWALL TAPE. 6. NAILING: A. NAILS SHOULD BE DRIVEN SO THAT THE HEAD LIES IN A SMALL DIMPLE FORMED BY THE LAST BLOW OF THE HAMMER. TAKE CARE NOT TO FRACTURE THE BOARD WHEN NAILING. FRACTURES OF THE WALLBOARD CAUSED BY OVER DRIVING MUST BE CORRECTED BY ADDITIONAL NAILING. NAILS MUST BE BETWEEN 3/8" AND 1" FROM THE EDGES, AND NAILS ON ADJACENT EDGES SHOULD BE OPPOSITE EACH OTHER. IF YOU ARE USING THE SINGLE NAILING SYSTEM, THE NAILS SHOULD BE SPACED 7" ON CENTER ON THE CEILINGS AND 8" ON CENTER ON THE WALLS. THE DOUBLE NAILING SYSTEM IS ALSO PERMITTED. GROUPS OF TWO NAILS 2 - 2 1/2" APART ARE SPACED 12" ON CENTER IN THIS SYSTEM. APPROVED SCREWS MAY ALSO BE USED TO APPLY WALLBOARD. B. SCREWS MUST BE PLACED 3/8" FROM THE END OR EDGES OF THE BOARD AND SPACED 12" ON CENTER. SCREWS MUST BE USED FOR FASTENING WALLBOARD AT POCKET DOORS. C. FASTENERS AT THE TOP AND BOTTOM PLATES OF VERTICAL ASSEMBLIES, OR THE EDGES AND ENDS OF HORIZONTAL ASSEMBLIES PERPENDICULAR TO SUPPORTS, AND AT THE WALL LINE MAY BE OMITTED EXCEPT ON SHEAR- RESISTING ELEMENTS OR FIRE RESISTIVE ASSEMBLIES. ALL EDGES OF BRACED WALL PANELS AND FIREWALLS MUST BE NAILED TO FRAMING. 7. CORNERS: A. ALL METAL REINFORCED CORNERS MUST FIT SNUGLY AGAINST WALLBOARD AND SHOULD BE NAILED APPROXIMATELY 12" ON CENTER. B. ALL "L" EDGE METAL TRIM SHOULD BE NAILED EVERY 6". PAPERBACK CORNER BEAD IS ACCEPTABLE IF INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 8. BATHROOM: A. WATERPROOF CEMENT WALL BOARD SHALL BE USED IN THE BATHROOM AND BACKED WITH A VAPOR BARRIER. 9. DRYWALL FASTENERS: A. 6D CEMENT-COATED BOX NAIL, OR 1 7/8" DRYWALL NAIL B. SCREWS SHALL BE LONG ENOUGH FOR THE FULL-DIAMETER PORTION TO PENETRATE INTO WOOD FRAMING NOT LESS THAN 5/8 INCH AND THROUGH METAL FRAMING NOT LESS THAN 1/4 INCH. DOORS AND WINDOWS DOORS AND WINDOWS SCHEDULE NOTES:SCHEDULE NOTES: ROOM FINISHES NOTES:ROOM FINISHES NOTES: DRYWALL:DRYWALL: 1. SEE FINISH SCHEDULE FOR FINISH INFORMATION ON SPECIFIC ROOMS. 2. BATHROOM TILES AND UNDERLAYMENT SHALL BE TYPE AND COLOR AS SELECTED BY PROJECT CONTACT. 3. FLOOR PLANKS SHALL BE TYPE AND COLOR AS SELECTED BY PROJECT CONTACT. 4. TOP OF PLANK FLOOR TO BE FLUSH WITH TOP OF BATHROOM TILE FLOORING. 5. KITCHEN COUNTER-TOPS, SPLASH AND CABINETRY SHALL BE COLOR AND FINISH AS SELECTED BY PROJECT CONTACT. 6. CONSULT PROJECT CONTACT FOR ALL INTERIOR TRIM INCLUDING, BUT NOT LIMITED TO, CEILING MOLDINGS, LIGHTING MOLDINGS, WOOD BASES AND DOOR AND WINDOW CASINGS. TYPICAL ASSEMBLIESTYPICAL ASSEMBLIES CONTRACTOR TO VERIFY ALL SIZES IN THE FIELD PRIOR TO ORDERING DOORS. GRAY LAMINATE ARCHITECTURAL ROOFING SHINGLES WOOD SIDING MATCH EXISTING 0' - 4 " ALL NEW EXTERIOR DOORS SHALL BE FRENCH MULTI-LITE DOORS. ALL WINDOWS SHALL HAVE A 5.5 ” TRIM WIDTH, 2 ” SILL, AND 3.5 ” APRON TO MATCH THE EXISTING BUILDINGS. Window Schedule Window Type Width Height Sill Height Finish Comments 01 3' - 0"4' - 0"3' - 0"VINYL U - FACTOR 0.3, SHGC 0.23 02 2' - 0"3' - 0"4' - 0"VINYL U - FACTOR 0.3, SHGC 0.23 03 2' - 6"4' - 0"3' - 0"VINYL U - FACTOR 0.3, SHGC 0.23 WINDOW TYPESWINDOW TYPES WINDOW SCHEDULEWINDOW SCHEDULE CONTRACTOR TO VERIFY ALL SIZES IN THE FIELD PRIOR TO ORDERING WINDOWS. THE NEW WINDOWS WILL MATCH THE EXISTING WINDOW TRIM FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS FOR VERIFICATION OF THE BUILDING INSPECTOR.” 110.6(A)(5) REV DATE REMARKS 1 10.03.2024 City Correction 2 06.25.2025 City Correction OFF-WHITE COLOR MATCH THE PROPOSED WINDOWS FOR THE PRIMARY DWELLING 2 2 2 FINISH FLOOR BASE INSULATION 1/2" GYP. BD. EA. SIDE O/ 2X4 WOOD STUD, 16" O.C.- SEE WALL LEGEND. 1/2" GYPSUM BOARD 2X4 BOTTOM PLATE CEILING FRAMING MEMBER, SEE STRUCTURAL DRAWINGS SHIM SECONDARY WEATHER BARRIER PERMABASE CEMENT BOARD FACADES BASE COAT/ADHESIVE WITH EMBEDDED MONOMESH AT JOINTS CHAMELEON COLOR FINISH CLOSING BEAD APPROVED SEALANT.USE CLOSED CELL BACKER ROD,IF GAP GREATER THAN 1/4" DRIP EDGE FLASHING 1/2" GYP 5/8" PLYWOOD INSULATION RECESSED CEILING LIGHT ALLOW AIR SPACE PER MANUF. RECOMMENDATION 4 MIL POLY VB STUCCO WARP OR EQUIVALENT WOVEN WIRE FABRIC OR EXPANDED METAL LATH FS23 MULTI PRIMER COLOR FINISH FASTENER CASING BEAD FLASHING (BY OTHERS) WARP DUPONT TYVEK STUCCO WRAP OR EQUIVALENT INTO OPENING SEALANT WINDOW FASTENER WINDOW SEALANT OVER BACKER ROD WARP DUPONT TYVEK STUCCO WRAP OR EQUIVALENT INTO OPENING CASING BEAD FINISH FS23 MULTI PRIMER SCRATCH/BROWN COAT WITH STUCORITE ADMIX WOVEN WIRE FABRIC OR EXPANDED METAL LATH STUCCO WARP OR EQUIVALENT SUBSTRATE SILL PAN FLOOR FINISH CONCRETE FOUNDATION. DO NOT PAINT. FACE OF INT. FINISH WOOD SIDING OVER METAL LATH AND 2-LAYER BUILDING PAPER OR APPROVED BUILDING WRAP . R15 KRAFT FACED HIGH PERFORMANCE FIBERGLASS BATT INSULATION 991375 BY CERTAINTEED O.A.E. FINISH GRADE NO. 26 GALVANIZED SHEET GAGE (19 MIL) OR 50 MIL PVC NONCORROSIVE WEEP SCREED THAT PERMITS TRAPPED WATER TO ESCAPE FROM BEHIND THE EXTERIOR WALL COVERING; WITH A MINIMUM 3-1/2 ” TALL ATTACHMENT FLANGE PLACED AT OR BELOW THE SILL/CONCRETE INTERFACE; AND WITH THE WEEP SCREED PLACED A MINIMUM OF 4 INCHES ABOVE EARTH OR 2 INCHES ABOVE PAVED AREAS. 5/8" PLYWOOD SHEATHING SUBFLOOR UNDERLAYMENT PER STRUCTURAL PLAN BOTTOM OF FLANGE SET BELOW TOP OF FUNDATION AND PLATE LINE MI N 4 " NEW (2) LAYERS OF 15# FELT LAID WITH 19" OVERLAP OF WATERPROOFING UNDERLAYMENT FIRST AND SUCCEEDING COURSES OF UNDERLAY TO BE 36" WIDE AND LAPPED 19"2-PLY UNDERLAYMENT TYPE 15 FELT SEALING STRIP APPROVED SELF-SEALING SHINGLES OR INTERLOCKING SHINGLES 18" 36"17" 19" RIDGE SHINGLE METAL RIDGE FLASH ROOF SHINGLES UNDERLAYMENT PLYWD SHEATHING PROVIDE HOLES & KNOTCHES PER FOR CROSS-VENT 2* RIDGE BOARD / BLKG SEE ELEV RIDGE CAP E.N.E.N. 4" MIN DOOR PER SCHEDULE 2" ALUMINUM THRESHOLD, OR THRESHOLD MATERIAL TO MATCH ADJACENT FLOOR FINISH MATERIAL FLOOR FINISH PER OWNER 1/ 2 " M A X ALUMINUM THRESHOLD DOOR SHOE WITH INTEGRAL DRIP BUMPER SEAL SET THRESHOLD IN A BED OF SEALANT CONTINUOUS ALONG BACK EDGE AND BOTH JAMBS DOOR AS SCHEDULED THRESHOLD FASTENERS SET IN SEALANT SHEET METAL SILL PAN, SEE SILL END DAM BEYOND INT EXT PEDESTRIAN TRAFFIC COATING 5/8" GYP BD ON 2X FRAMING SLIDING DOOR TRACK AND HARDWARE 7/8" STUCCO, MATCH EXISTING 2X6 P.G. CEDAR FASICA 2X4 EXT.WALL FRAMIN R-15 INSUL.TYP.U.O.N. 12 1/2" GYPSUM BOARD, AT WALL 1/2" GYPSUM BOARD, TY AT CEILINGS. R-30 ATTIC INSUL,TYP. G.S.M. OGEE GUTTERS W/ LEAF GUARDS TO MATCH EXISTING. 1X6 T&G ROUGH SAWN STARTER BOARD 2 x 4 BLOCK CLASS "A" 30-YR ASPHALT-COMP. SHINGLE PROOFING OVER APPROVED UNDERLAYMENT OVER PLYW. SHTG. PER STRUCT. DRWGS 4 TYP. U.O.N. 7/8" STUCCO GYP 5/8" TYPE X GALVANIZED STEEL HALF ROUND DORMER VENT. REFER TO ATTIC CALCULATION ROOF VENT W/ SCREEN ROOF VENTS W/ WIRE MESH OF LESS THAN 1/4" OPENING SHEATING SCALE 3" = 1'-0"WALL TYPE B (INTERIOR WALL)1 SCALE 3" = 1'-0"DOOR HEAD 3 SCALE 1 1/2" = 1'-0"RECESSED LIGHTING 4 DATE: P.M.: DRAWN BY: JOB NO.: 26081 Merit Cir, STE 111 Laguna Hills, CA 92653 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D ES I GNBUILDCNI 7/ 2 / 2 0 2 5 1 0 : 2 9 : 4 7 A M A5.0 B.N B.N DETAILS 07.11.24 2024001108 UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT SCALE 3" = 1'-0"WINDOW HEADER DETAIL.7 SCALE 3" = 1'-0"WINDOW SILL DETAIL.8 SCALE 3" = 1'-0"FOUNDATION EDGE DETAIL.5 SCALE 12" = 1'-0"UNDERLAYMENT 12 SCALE 3" = 1'-0"TYPICAL RIDGE DETAIL.11 REV DATE REMARKS SCALE 3" = 1'-0"INTERIOR DOOR SILL 13 SCALE 3" = 1'-0"EXTERIOR DOOR TRASHHOLD 14 SCALE 3" = 1'-0"CLOSET DOOR HEAD 15 SCALE 3" = 1'-0"1HR ROOF EAVE DETAIL 9 1.REINFORCING STEEL SHALL BE PLACED IN ACCORDANCE TO AMERICAN CONCRETE INSTITUTE ACI 301 “SPECIFICATIONS FOR STRUCTURAL CONCRETE” AND CONCRETE REINFORCING STEEL INSTITUTE (CRSI) “MANUAL OF STANDARD PRACTICE.” 2.REINFORCING STEEL FOR FOUNDATIONS, SLABS ON GRADE, AND ELEVATED SLABS SHALL CONFORM TO ASTM A615/A615M, GRADE 60, UNLESS NOTED OTHERWISE. BARS TO BE WELDED SHALL CONFORM TO LOW ALLOY ASTM A706/A706M, GRADE 60. 3.WELDED WIRE REINFORCEMENT (WWR) SHALL CONFORM TO ASTM A1064/A1064M. SPLICE LENGTH FOR WELDED WIRE REINFORCEMENT SHALL BE AT LEAST 8 INCHES, MEASURED BETWEEN OUTERMOST CROSS WIRE OF EACH REINFORCEMENT SHEET. 4.ALL REINFORCING STEEL SHALL BE SPLICED AS SPECIFIED ON THESE DRAWINGS. IF NO LOCATION IS SPECIFIED, LOCATE SPLICES IN AREAS OF MINIMUM STRESS. SPLICE LENGTHS SHALL NOT BE LESS THAN THE LENGTHS INDICATED ON THESE DRAWINGS. 5.MINIMUM CONCRETE COVER AND CLEARANCES BETWEEN REINFORCING STEEL BARS SHALL BE SATISFIED AT ALL LOCATIONS INCLUDING SPLICES. THE CLEARANCE BETWEEN THE REINFORCING STEEL BARS SHALL NOT BE LESS THAT THE GREATER VALUE OF ONE BAR DIAMETER, ONE INCH, AND 4/3 TIMES THE MAXIMUM SIZE OF THE AGGREGATE. AT COLUMNS AND BEAM, PROVIDE 1 1/2 INCHES OR 1.5 TIMES THE LARGEST LONGITUDINAL BAR DIAMETER, WHICHEVER IS GREATER. FOR CONSIDERING THE COVER AND CLEAR DISTANCE IN BUNDLED BARS, TOTAL AREA OF BUNDLE SHALL BE CONSIDERED FOR CALCULATING EQUIVALENT BAR DIAMETER. 6.CONCRETE COVERAGE FOR REINFORCING STEEL PLACED IN CAST-IN-PLACE CONCRETE SHALL BE AS TABLE CONCOV-1. 7.IF SPACERS AND CHAIRS ARE RESTING ON EXPOSED CONCRETE SURFACES, THEY SHALL BE PASTIC COATED OR USE PLASTIC. 8.ELECTRODES UTILIZED IN WELDING OF REINFORCING STEEL, SHALL BE LOW HYDROGEN ELECTRODE AS SPECIFIED IN AMERICAN WELD SOCIETY AWS D1.4 “STRUCTURAL WELDING CODE - REINFORCING STEEL.” 9.ALL REINFORCING STEEL SHALL BE BENT COLD AND PRIOR TO PLACING THE BARS. RE-BENDING OF PREVIOUSLY BENT REINFORCING STEEL IS NOT PERMITTED. BENDING OF REINFORCEMENT IN PREVIOUSLY CAST CONCRETE IS NOT PERMITTED. OFFSET BARS SHALL BE BENT PRIOR TO PLACEMENT IN THE FORMS. HOOKING AND WALKING-IN ARE NOT PERMITTED. 10.FIRMLY SECURE ALL REINFORCING STEEL BARS AND WELDED WIRE REINFORCING WHILE PLACING CONCRETE. WHERE REQUIRED, ADDITIONAL CHAIRS, CONCRETE BLOCKS, STEEL BARS, BOLSTERS, OR OTHER APPROVED MEANS AND METHODS SHALL BE PROVIDED BY THE CONTRACTOR TO FURNISH ALL REQUIRED SUPPORTS FOR ALL REINFORCING. 11.PRIOR TO FINAL INSPECTION, CLEARLY MARK ALL REINFORCING STEEL SO THEIR IDENTIFICATION CAN BE PROPERLY MADE AT THE TIME OF INSPECTION. REINFORCING STEEL BAR SIZE NO. YIELD STRENGTH OF STEEL 60,000 PSI (420 MPA) SPLICE LENGTH OR TENSION DEVELOPMENT LENGTH (IN.) LAP SPLICE LENGTH-TENSION 4 30 5 38 6 45 TENSION DEVELOPMENT LENGTH FOR STRAIGHT BAR 4 23 5 28 6 34 TENSION DEVELOPMENT LENGTH FOR: A. 90° AND 180° STANDARD HOOKS WITH NOT LESS THAN 2 1/2" OF SIDE COVER PERPENDICULAR TO PLANE OF HOOK. B. 90° STANDARD HOOKS WITH NOT LESS THAN 2" OF COVER ON THE BAR EXTENSION BEYOND THE HOOK. 4 9 5 11 6 13 TENSION DEVELOPMENT LENGTH FOR BAR WITH 90° OR 180° STANDARD HOOK HAVING LESS COVER THAN REQUIRED IN ITEMS A AND B. 4 12 5 15 6 18 TABLE CAST-1. CONCRETE MINIMUM MECHANICAL PROPERTIES LOCATION COMPRESSIVE STRENGTH (PSI)TYPE FOOTING 4,500 NORMAL WEIGHT (145 PCF) SLAB-ON-GROUND 4,500 NORMAL WEIGHT (145 PCF) ALL OTHER STRUCTURAL ELEMENTS 4,500 NORMAL WEIGHT (145 PCF) TABLE FUND-1. SOIL PROPERTIES PARAMETER VALUE UNIT ALLOWABLE BEARING CAPACITY (D+L)1,500 PSF FRICTION COEFFICIENT N/A PASSIVE SOIL RESISTANCE N/A PCF AT REST SOIL PRESSURE N/A PCF ACTIVE SOIL PRESSURE N/A PCF INCREMENTAL SEISMIC PRESSURE N/A PCF 1.ALL CONCRETE WORK SHALL CONFORM TO THE STANDARDS OF THE AMERICAN CONCRETE INSTITUTE, ACI 301 “SPECIFICATION FOR STRUCTURAL CONCRETE” AND ALL APPLICABLE MODIFICATIONS AS NOTED IN THE CONTRACT DOCUMENTS OR BY LOCAL AUTHORITIES. 2.CONCRETE SHALL ATTAIN THE FOLLOWING MINIMUM MECHANICAL PROPERTIES AT 28-DAY, UNLESS NOTED OTHERWISE IN TABLE CAST-1. 3.UNLESS NOTED OTHERWISE IN GEOTECHNICAL REPORT OR CONTRACT DOCUMENTS, CONCRETE MIX SHALL CONFORM TO THE REQUIREMENTS FOR CONCRETE ASSIGNED TO EXPOSURE CLASSES F1, S2, W0, AND C1, AS DEFINED IN TABLE 19.3.1.1 OF ACI 318. 4.UNLESS NOTED OTHERWISE IN GEOTECHNICAL REPORT OR CONTRACT DOCUMENTS, PORTLAND CEMENT FOR CONCRETE SHALL CONFORM TO ASTM C150 TYPE V. 5.UNLESS NOTED OTHERWISE IN CONTRACT DOCUMENTS, WATER CEMENT RATIO (W/cm) SHALL BE BASED ON THE REQUIREMENTS FOR SPECIFIED EXPOSURES, AND IT SHALL NOT EXCEED 0.45. 6.DETERIORATED OR CONTAMINATED MATERIALS SHALL NOT BE USED IN CONCRETE PRODUCTION. CONCRETE PRODUCTION INCLUDING EQUIPMENT USED TO MIX; BATCH AND DELIVERY SHALL CONFORM TO ASTM C94 OR ASTM C685. 7.CONCRETE SHALL BE MOIST CURED FOR AT LEAST 7 DAYS OF PLACEMENT EXCEPT IF APPROVED ACCELERATED CURING COMPOUND OR HIGH-SOLIDS CURING COMPOUND IS USED. 8.THE CONCRETE MAINTAINED AT A TEMPERATURE OF AT LEAST 50°F DURING THE CURING TIME BUT NOT LESS THAN 7 DAYS. 9.UNLESS APPROVED BY ARCHITECT, NO CURING COMPOUNDS, SEALERS, HARDENERS, ETC., SHALL BE ADDED TO OR APPLIED ON CONCRETE RECEIVING FINISHES. 10.AGGREGATE SHALL CONFORM TO ASTM C33 FOR NORMALWEIGHT CONCRETE. NORMALWEIGHT CONCRETE SHALL HAVE A MINIMUM DRY UNIT WEIGHT OF 145 PCF. 11.MAXIMUM AGGREGATE SIZE FOR FOUNDATION CONCRETE SHALL BE 1-1/2 IN. MAXIMUM AGGREGATE SIZE FOR OTHER MEMBERS SHALL BE 1 IN. BUT NOT LARGER THAN THE LEAST OF, ¾ THE MINIMUM CLEAR SPACING BETWEEN REINFORCING STEEL BARS INCLUDING SPLICES AND 1/5 THE NARROWEST DIMENSIONS BETWEEN SIDE OF THE FORMS. 12.FRESH CONCRETE SLUMP IN FLATWORK SHALL NOT BE MORE THAN 4 INCHES. 13.CONCRETE MIX SHALL BE BASED ON THE REQUIREMENTS STATED IN SECTION 4.2.3 OF ACI 301 FOR TRIAL MIXTURE OR/AND FIELD EXPERIENCES. 14.UNLESS NOTED OTHERWISE, ALL PREVIOUSLY HARDENED CONCRETE AT CONSTRUCTION JOINT SHALL BE CLEAN, FREE OF LAITANCE, AND INTENTIONALLY ROUGHENED TO FULL AMPLITUDE OF ¼ IN. PRIOR TO FRESH CONCRETE PLACEMENT. 15.UNLESS APPROVED BY THE STRUCTURAL ENGINEER, CENTER TO CENTER SPACING OF THE PIPES AND CONDUITS SHALL NOT BE LESS THAN 3 TIMES THE LARGEST DIAMETER OF PIPES OR CONDUITS, AND CLEAR SPACING BETWEEN THE EMBEDMENTS SHALL NOT BE LESS THAN 4 IN. 16.EMBEDMENTS PARALLEL TO THE CONSTRUCTION JOINTS SHALL NOT BE PLACED CLOSER THAN DEVELOPMENT LENGTH OF THE LARGER BAR CROSSING THE CONSTRUCTION JOINT. CROSSING OF THE CONDUITS SHALL NOT BE PERMITTED. 17.PIPES AND CONDUITS SHALL BE PLACED IN THE MIDDLE THIRD OF THE SLAB, FOUNDATION, AND WALL THICKNESS OR BEAM AND GIRDER SIDE DIMENSION. 18.SLEEVES SHALL BE PROVIDED FOR PLUMBING AND ELECTRICAL PENETRATIONS AND OPENINGS. ALUMINUM EMBEDMENTS SHALL BE COATED OR COVERED. NO CONTACT BETWEEN ALUMINUM AND CONCRETE OR ELECTROLYTIC ACTION BETWEEN ALUMINUM AND STEEL IS PERMITTED. 19.DO NOT DAMAGE REINFORCING STEEL. WHERE CONFLICT OCCURS BETWEEN REINFORCING STEEL AND EMBEDMENTS OR SLEEVES LAYOUT, REPOSITION THE SLEEVES OR REINFORCING STEEL. UNLESS APPROVED BY STRUCTURAL ENGINEER, CORING IS NOT PERMITTED. 20.CONCRETE SHALL BE PLACED IN ACCORDANCE WITH ACI 304. PROPERLY SECURE ALL REINFORCING STEEL, EMBEDMENT PARTS, PIPES, CONDUITS, ANCHORS, AND OTHER CONCRETE EMBEDMENTS IN POSITION, PRIOR TO PLACING CONCRETE. REMOVE DEBRIS AND CLEAN REINFORCING STEELS AND FORM PRIOR TO PLACING CONCRETE. 21.KEYED CONSTRUCTION JOIST SHALL BE PROVIDED AS SHOWN ON THESE DRAWINGS. 22.FORMWORK DESIGN, CONSTRUCTION, AND REMOVAL SHALL BE IN ACCORDANCE WITH ACI 347 AND ACI 347.2R. CONSTRUCTION LOADS MAY BE GREATER THAN THE SPECIFIED STRUCTURAL LIVE LOADS. 23.GROUT SHALL BE NON-METALLIC, NON-SHRINK AND SHALL ATTAIN A 28-DAY COMPRESSIVE STRENGTH OF AT LEAST TWICE THE STRENGTH OF THE CONCRETE BEARING ON, BUT NOT LESS THAN 7,000 PSI. GROUT SHALL NOT CONTAIN CHLORIDES. UNLESS APPROVED BY STRUCTURAL ENGINEER, GROUT THICKNESS SHALL NOT BE LESS THAN 1 IN. INFORM STRUCTURAL ENGINEER FOR WRITTEN APPROVAL WHERE GROUT WITH MORE THAN 1 1/2 IN. THICKNESS IS REQUIRED. 24.WHERE LEAN CONCRETE IS SPECIFIED ON THE DRAWINGS, LEAN CONCRETE SHALL CONTAIN A MINIMUM OF 2 SACKS OF CEMENT PER CUBIC YARD ON CONCRETE. 25.ALUMINUM OR ALUMINUM ALLOY PIPES SHALL NOT BE USED FOR PUMPING AND DELIVERING FRESH CONCRETE. 26.UNLESS NOTED OTHERWISE BY STRUCTURAL ENGINEER OR CONTRACT DOCUMENTS, AT LEAST TWO 6X12 IN. OR THREE 4X8 IN. CONCRETE SAMPLES SHALL BE MOLDED, FIELD-CURED, AND TESTED IN ACCORDANCE WITH ASTM C31 AND ASTM C39. 27.CONCRETING IN HOT WEATHER AND COLD WEATHER SHALL BE IN ACCORDANCE WITH ACI 305.1 AND ACI 306.1 AND ACI 301. ACI 301 SHALL BE CONSIDERED AS GOVERNING DOCUMENT UNLESS NOTE OTHERWISE ON THE CONTRACT SPECIFICATIONS OR DOCUMENTS. 28.IF ANCHOR BOLTS ARE PLACED IN THE TOP OF A COLUMNS PILE OR PEDESTAL, THE BOLTS SHALL BE ENCLOSED BY TRANSVERSE REINFORCEMENT THAT ALSO SURROUNDS AT LEAST FOUR LONGITUDINAL BARS WITHIN THE PILE OR PEDESTAL. THE TRANSVERSE REINFORCEMENT SHALL BE DISTRIBUTED WITHIN THE TOP 5 IN. OF THE COLUMN OR PEDESTAL AND SHALL CONSIST OF AT LEAST TWO NO. 4 OR THREE NO. 3 BARS. 29.THE TESTING AGENCY PERFORMING ACCEPTANCE TESTING SHALL COMPLY WITH ASTM C1077. CAST IN PLACE CONCRETE FOUNDATIONS 1.NO GEOTECHNICAL REPORT WAS PROVIDED. THE DESIGN OF FOUNDATION IS BASED ON THE DEFAULT VALUE PROVIDED IN FOUNDATION REQUIREMENTS FOR RESIDENTIAL PROJECTS AND ACCESSORY STRUCTURES DATED 06/22/2020 BY THE COUNTY OF ORANGE DEPARTMENT OF PUBLIC WORKS. SEE TABLE FUND-1 FOR THE DESIGN PARAMETERS RECOMMENDED BY THE ABOVE REFERENCED DOCUMENT AND WERE CONSIDERED FOR THE FOUNDATION DESIGN OF THIS PROJECT. A 33% INCREASE FOR BEARING CAPACITY WAS CONSIDERED FOR LOAD COMBINATIONS INCLUDING WIND OR SEISMIC LOADS. 2.EXTERIOR & INTERIOR FOUNDATIONS SHALL BE CARRIED AT LEAST 24 IN. INTO FIRM UNDISTURBED NATURAL OR COMPACTED SOIL UNO ON THE PLANS OR DETAILS. 3.EXCAVATION AND STABILITY OF SLOPES ARE NOT PART OF THE DESIGN SCOPE, AND CONTRACTOR SHALL REMAIN SOLELY RESPONSIBLE FOR ALL EXCAVATION PROCEDURES INCLUDING BUT NOT LIMITED TO LAGGING, SHORING, RESHORING UNDERPINNING AND PROTECTION OF EXISTING CONSTRUCTION. 4.NO CONSTRUCTION, EXPANSION OR COLD JOINTS ARE PERMITTED IN THE FOUNDATIONS AND GRADE BEAMS, UNLESS SPECIFICALLY SHOWN ON THESE DRAWINGS. 5.STANDING WATER SHALL BE REMOVED FROM THE FOUNDATION EXCAVATIONS PRIOR TO THE CONCRETE PLACING. 6.NOTIFY THE OWNER'S REPRESENTATIVE, IF ANY BURIED CONSTRUCTIONS THAT ARE NOT INDICATED ON THESE DRAWINGS ARE FOUND ON THE CONSTRUCTION SITE. UNLESS SPECIFICALLY SHOWN ON THESE DRAWINGS, DO NOT DAMAGE ANY EXISTING BURIED STRUCTURES SUCH AS CESSPOOLS, CISTERNS, FOUNDATIONS, ETC. 7.LOCATE ALL UTILITIES PRIOR TO COMMENCING THE WORK. EXISTING EMBEDDED OR SURFACE UTILITIES SHALL BE PROTECTED TO REMAIN UNDAMAGED DURING AND AFTER CONSTRUCTION WORK. 8.UNLESS NOTED OTHERWISE, OR REQUIRED BY THE LOCAL AUTHORITIES, REMOVE ABANDONED FOUNDATIONS, UTILITIES, PIPES, ETC. WHEREVER INTERFERE WITH THE NEW CONSTRUCTION OR IMPOSE DANGERS. 9.UNLESS NOTED OTHERWISE ON CONTRACTUAL DOCUMENTS, OR REQUIRED BY THE LOCAL AUTHORITIES, EXCAVATIONS FOR FOUNDATIONS MUST BE ACCEPTED BY THE APPROVED REPRESENTATIVE OF GEOTECHNICAL ENGINEER OR INSPECTORS PRIOR TO PLACING REINFORCING AND CONCRETE. NOTIFY THE GEOTECHNICAL ENGINEER WHEN EXCAVATIONS ARE READY FOR INSPECTION. 10.WHERE EXCAVATION IS CAPABLE OF MAINTAINING A VERTICAL CUT WITHOUT SLOUGHING, FOUNDATIONS MAY BE CAST DIRECTLY AGAINST EXCAVATIONS PROVIDED. WHERE FOUNDATIONS ARE CAST AGAINST EARTH, DIMENSIONS OF THE FOUNDATIONS SHALL BE ENLARGED BY AN ADDITIONAL ONE INCH IN THE DIRECTION OF THE SIDE CAST AGAINST EARTH. 11.CONCRETE SHALL NOT BE PLACED ON FROZEN GRADE. FOUNDATIONS THAT MAY SUBJECT TO FREEZING TEMPERATURES AFTER FOUNDATION CONSTRUCTION SHALL BE ADEQUATELY PROTECTED FROM FREEZING. 12.ALL EARTHWORK INCLUDING BUT NOT LIMITED TO EXCAVATION, BACKFILL, AND COMPACTION SHALL BE DONE IN STRICT ACCORDANCE WITH THE RECOMMENDATIONS STATED IN GEOTECHNICAL INVESTIGATION REPORT OR THE REQUIREMENTS OF THE CITY OF THE PROJECT. 13.FOUNDATION EXCAVATION, BACKFILLING, AND COMPACTION SHALL BE OBSERVED AND APPROVED BY THE GEOTECHNICAL ENGINEER OF RECORD, IF APPLICABLE, AND THE GOVERNING AGENCY PRIOR TO PLACING REINFORCING STEEL AND CONCRETE. GEOTECHNICAL ENGINEER SHALL PROVIDE A LETTER OF COMPLIANCE TO THE OWNER. 14.FOR SLOT-CUTTING METHOD OF EXCAVATION, PROVIDE SUPPORTING COMPUTATIONS BY A REGISTERED GEOTECHNICAL ENGINEER AND A DRAWING SHOWING THE LOCATION OF SLOTS, THEIR WIDTH AND SEQUENCE OF SLOT CUTS. SLOT CUT TO BE AT LEAST 36" AWAY FROM ANY PROPERTY LINES AND NOT EXCEED 5 FEET IN DEPTH. 15.TEMPORARY CUT SLOPES SHALL NOT EXCEED RECOMMENDED DEPTH IN THE GEOTECHNICAL INVESTIGATION REPORT. DO NOT PERMIT ANY PERSON TO DESCEND INTO TRENCHES OR EXCAVATIONS GREATER THAN FIVE FEET IN DEPTH UNLESS NECESSARY PERMIT FROM STATE OF CALIFORNIA DIVISION OF INDUSTRIAL SAFETY IS OBTAINED PRIOR TO ISSUANCE OF BUILDING OR GRADING PERMIT. CONTRACTOR SHALL PROVIDE FOR DESIGN, PERMIT, AND INSTALLATION OF ALL SHORING AND SHEATHING NECESSARY TO SAFELY RETAIN EARTH BANKS. 16.CONTRACTOR SHALL PROVIDE FOR DEWATERING OF EXCAVATIONS FROM SURFACE WATER, GROUNDWATER OR SEEPAGE. DEWATERING SHALL EFFECTIVELY ELIMINATE ANY HYDROSTATIC PRESSURE ON SHORING. ENSURE THAT CONTAMINATED WATER IS NOT DISPOSED OF IN PUBLIC SEWER OR STORM DRAIN SYSTEM AND ENSURE THAT DIRTY WATER IS NOT DISPOSED OF INTO PUBLIC RIGHT-OF-WAY. 17.SIDEWALKS OR PAVING IMMEDIATELY ADJACENT TO BUILDING PERIMETER SHALL BE SLOPED TO PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING. LANDSCAPE IRRIGATION IS NOT PERMITTED WITHIN FIVE FEET OF BUILDING PERIMETER FOOTINGS EXCEPT WHEN ENCLOSED IN PROTECTED PLANTERS THAT DIRECT DRAINAGE AWAY FROM STRUCTURE AND FOUNDATIONS. DISCHARGE FROM DOWNSPOUTS, ROOF DRAINS, AND SCUPPERS IS NOT PERMITTED ONTO UNPROTECTED SOILS WITHIN FIVE FEET OF BUILDING PERIMETER. 18.UNLESS ADEQUATELY BRACED AND SHORED, RETAINING WALLS SHALL NOT BE BACKFILLED UNTIL WALLS HAVE ATTAINED FULL DESIGN STRENGTH. FOR PIT WALLS AND BUILDING WALLS BELOW GRADE, BRACING AND SHORING SHALL REMAIN IN PLACE UNTIL ATTACHED FLOORS ARE PLACED, CURED FOR AT LEAST 7 DAYS, AND HAVE ATTAINED 70% DESIGN STRENGTH. BACKFILL PLACED IMMEDIATELY BEHIND RETAINING WALLS SHALL BE COMPACTED WITH HAND OPERATED EQUIPMENT. 19.WHERE THE STEEL COLUMNS ARE EXPOSED TO WEATHER, BASE PLATES AND COLUMNS UP TO 12" ABOVE THE CONCRETE SLAB SHALL BE COATED WITH MIN. 2 COATS OF MACROPOXY 646. 23. ALL PERMANENT STEELS IN CONTACT WITH WEATHER SHALL BE PROTECTED FOR CORROSION. TABLE WIND-1. WIND DESIGN DATA CASE VALUE BASIC WIND SPEED 95 MPH IMPORTANCE FACTOR, Iw 1.0 EXPOSURE CATEGORY B ENCLOSURE CLASSIFICATION ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT, GCpi ±0.18 WIND BASE SHEAR IN EAST- WEST DIRECTION 4.7 KIPS WIND BASE SHEAR IN NORTH- SOUTH DIRECTION 5.6 KIPS TABLE EQ-1. EARTHQUAKE DESIGN DATA PARAMETER VALUE SITE CLASS D-DEFAULT IMPORTANCE FACTOR, IE 1.0 MAPPED SPECTRAL RESPONSE ACCELERATION, SS 1.29 G MAPPED SPECTRAL RESPONSE ACCELERATION, S1 0.461 G SITE COEFFICIENT, FA 1.2 SITE COEFFICIENT, FV 1.839 DESIGN SPECTRAL RESPONSE COEFFICIENT, SDS 1.032 G DESIGN SPECTRAL RESPONSE COEFFICIENT, SD1 0.565 G SEISMIC DESIGN CATEGORY D RESPONSE MODIFICATION COEFFICIENT (S) OF LIGHT- FRAME (WOOD), R 6.5 OVERSTRENGTH FACTOR (WOOD), Ω0 3 DEFLECTION AMPLIFICATION FACTOR (WOOD), CD 4 SEISMIC RESPONSE COEFFICIENT, CS 0.159 (LRFD) SEISMIC BASE SHEAR OF LIGHT- FRAME (WOOD)4.5 KIPS ANALYSIS PROCEDURE ELF PROC AND CRC BRACED WALL METHOD. RESPONSE MODIFICATION COEFFICIENT (S) OF OMF (STEEL), R N/A OVERSTRENGTH FACTOR (STEEL), Ω0 N/A DEFLECTION AMPLIFICATION FACTOR (STEEL), CD N/A SEISMIC RESPONSE COEFFICIENT, CS N/A SEISMIC BASE SHEAR OF OMF (STEEL)N/A ANALYSIS PROCDURE N/A TABLE LL-1. MINIMUM LIVE LOAD RESIDENTIAL AREAS VALUE PRIVATE ROOMS AND CORRIDORS SERVING THEM 40 PSF PUBLIC ROOMS 100 PSF CORRIDORS SERVING PUBLIC ROOMS 100 PSF UNINHABITABLE ATTICS WITHOUT STORAGE 10 PSF UNINHABITABLE ATTICS WITH STORAGE 20 PSF HABITABLE ATTICS AND SLEEPING AREAS 30 PSF ALL OTHER AREAS 40 PSF BALCONIES AND DECKS 1.5 TIMES THE LIVE LOAD FOR THE AREA SERVED. NOT REQUIRED TO EXCEED 100 PSF ROOFS ORDINARY FLAT, PITCHED, AND CURVED ROOFS 20 PSF ROOF AREAS USED FOR OCCUPANTS SAME AS OCCUPANCY SERVED ROOF AREAS USED FOR ASSEMBLY PURPOSES 100 PSF 1.BN'S SCOPE OF WORK IS LIMITED TO PROVIDING STRUCTURAL DRAWINGS FOR THE NEW DETACHED ADU PROJECT LOCATED AT 606 S VAN NESS AVE, SANTA ANA, CA 92701. 2.THE SCOPE OF WORK DOES NOT INCLUDE THE ANALYSIS OR EVALUATIONS OF EXISTING STRUCTURE AS A WHOLE OR THE PORTIONS OF IT THAT IS NOT INCLUDED IN THIS SCOPE OF WORK FOR LATERAL AND GRAVITY LOADS. NO WARRANTY EXPRESSED OR IMPLIED TO THE ADEQUACY, CODE COMPLIANCE, OR CONFORMANCE OF THE EXISTING STRUCTURE IS MADE BY VIRTUE OF THIS DESIGN. THIS SCOPE OF WORK DOES NOT INCLUDE ANY VERIFICATION FOR THE CONFORMANCE OF THE EXISTING STRUCTURE TO THE PROVIDED DOCUMENTS OR CODE COMPLIANCE. 3.BN PERFORMED THE DESIGN CONSIDERING THE AVAILABLE INFORMATION FOR THE STRUCTURE. SHOULD ADDITIONAL INFORMATION BECOME AVAILABLE THAT BN WAS NOT AWARE OF, OR WHICH WAS UNKNOWN AT THE TIME OF ANALYSIS OR DESIGN, BN RESERVES THE RIGHT TO REVISE THE DESIGN AS NEEDED AND ADDITIONAL COSTS MAY BE REQUIRED. 4.BN PERFORMED THE STRUCTURAL DESIGN IN A MANNER CONSISTENT WITH THE LEVEL OF SKILL AND CARE ORDINARILY EXERCISED BY PROFESSIONAL ENGINEERS AND CONSULTANTS PRACTICING UNDER SIMILAR CONDITIONS. NO OTHER REPRESENTATION, WARRANTY, OR GUARANTEE IS GIVEN. PROVIDED OPINIONS ARE BASED ON OUR ENGINEERING JUDGMENT. BN WILL NOT BE RESPONSIBLE FOR LATENT DEFECTS THAT MAY APPEAR IN THE FUTURE OR FOR DIFFERENT OPINIONS OF OTHERS THAT MAY ARISE. 5.THE CLIENT IS SOLELY RESPONSIBLE FOR THE ACCURACY OF THE PROVIDED INFORMATION, AND STRUCTURAL ENGINEER DISCLAIMS ANY LIABILITIES FOR DISCREPANCIES BETWEEN THE DOCUMENTS THEMSELVES OR PROVIDED INFORMATION AND FIELD CONDITIONS. 6.STRUCTURAL OBSERVATION AND SPECIAL INSPECTIONS ARE NOT INCLUDED IN THIS SCOPE OF WORK. 7.ALL WORK SHALL BE INACCORDANCE WITH THE 2022 EDITION OF CALIFORNIA BUILDING CODE (CBC), CALIFORNIA RESIDENTIAL CODE (CRC), AND ALL AMENDMENTS OF THE CITY OF THE PROJECT LOCATION AND LOCAL AUTHORITIES INCLUDING LOCAL ORDINANCE. 8.ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE STANDARDS FOR THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) OF PROJECT STATE AND ALL APPLICABLE LOCAL CODES AND ORDINANCES. CONTRACTOR REMAINS SOLELY RESPONSIBLE FOR THE SAFTEY OF PERSONEL AND JOBSITE OF THIS CONTRACT DURING THE CONSTRUCTION. ENGINEER AND THE OWNER SHALL REMAIN HARMLESS FROM ANY AND ALL LIABILITIES OF THE CONSTRUCTION WORK. 9.THE JURISDICTION PERMIT SET SHALL NOT BE USED FOR ANY CONSTRUCTION OR COMMENCING THE WORK PRIOR TO ACQUIRING THE JURISDICTION’S PERMIT. BN SHALL HAVE NO LIABILITY OR RESPONSIBILITY FOR THE SAFETY, AND/OR COSTS OF ANY CONSTRUCTION THAT IS PERFORMED PRIOR TO ACQUIRING THE JURISDICTION’S PERMIT. FAILURE TO OBTAIN A BUILDING PERMIT IS A VIOLATION OF CONTRACTORS LICENSE LAW. CONSTRUCTION PERFORMED WITHOUT A PERMIT CAN EXPOSE A HOMEOWNER TO ADDITIONAL LIABILITY AND COSTS. 10.CONSTRUCTION DOCUMENTS IDENTIFIED AS BID SET OR ISSUED FOR PERMIT ON ANY OR ALL SHEETS ARE SUBJECTED TO REVIEW AND APPROVAL BY BUILDING OFFICIALS. THIS REVIEW MAY RESULT CHANGES TO THE DOCUMENTS. DRAWING SETS/SHEETS THAT ARE NOT APPROVED BY BUILDING OFFICIALS SHALL NOT BE USED FOR ANY CONSTRUCTION OR COMMENCING ANY PREPARATION WORK. THESE DOCUMENTS ARE NOT CONSTRUED AS BEING THE COMPLETED OR FINAL CONSTRUCTION DOCUMENTS AND THEY SHALL NOT IN ANY WAY BE USED AS SUCH. 11.DESIGN OF HANDRAILS AND GUARDRAILS ARE NOT INCLUDED WITH THIS SCOPE OF WORK. 12.ALL GUARDRAILS AND HANDRAILS SHALL BE DESIGNED TO WITHSTAND A LATERAL POINT LOAD OF 200 POUNDS APPLIED HORIZONTALLY AT RIGHT ANGLES, AT ANY POINT TO TOP RAIL. A 50 PLF LOAD IS REQUIRED AT 3-STORY AND MULTI-FAMILY. 13.THESE DRAWINGS ARE PROVIDED SPECIFICALLY FOR THE PROJECT LISTED ON THE TITLE BLOCK AND ANY REUSE OR REPRODUCE OF THE DRAWINGS AND DETAILS AS A WHOLE, OR A PART ARE STRICTLY PROHIBITED UNLESS A WRITTEN APPROVAL FROM THE ENGINEER IS ISSUED. 14.CONTRACTOR SHALL COORDINATE FOR ALL INSPECTIONS AND SPECIAL INSPECTIONS THAT ARE REQUIRED BY LOCAL AUTHORITIES FOR THE WORK. ALL REPORTS SHALL BE SUBMITTED TO THE OWNER AND ENGINEERS PRIOR TO THE CONCLUDING OF THE WORK. ALL REPORTED DEFICIENCIES IDENTIFIED BY THE STRUCTURAL OBSERVER SHALL BE REPAIRED AT NO COSTS TO THE OWNER OR ENGINEERS PRIOR TO CONCLUSION OF WORK. 15.ALL DIMENSIONS SHALL BE VERIFIED IN FIELD PRIOR TO COMMENCEMENT OF WORK. ANY DISCREPANCIES BETWEEN THE DIMENSION SHOWN ON THESE DRAWINGS AND CIVIL DRAWINGS, ARCHITECTURAL DRAWINGS OR FIELD CONDITIONS SHALL BE REPORTED TO THE ENGINEER. ALL OPENINGS' LAYOUT, EMBEDMENTS, SLEEVES, AND PENETRATIONS FOR ARCHITECTURAL, MECHANICAL, AND ELECTRICAL ATTACHMENTS SHALL BE VERIFIED PRIOR TO PERFORMING THE WORK. NO WORK SHALL BE PERFORMED UNTIL THE DISCREPANCIES ARE RESOLVED. 16.REVIEW ALL CONTRACT DOCUMENTS FOR THE SCOPE OF WORK AND CONTRACTOR MINIMUM RESPONSIBILITIES. PROJECT DOCUMENTS INCLUDE INFORMATION REQUIRED TO CONVEY THE DESIGN INTENT. NOTIFY THE ENGINEER PRIOR TO COMMENCING OF THE WORK, IF ANY CLARIFICATIONS OF THE DESIGN ARE NEEDED. 17.THE DRAWINGS SHALL NOT BE SCALED. SPECIFIC DIMENSIONS SHOWN ON THE DRAWINGS, TAKE PRECEDENCE OVER THE SCALED DRAWINGS. 18.CONTRACTOR SHALL SCHEDULING SEQUENCE OF ALL WORK AND SUBCONTRACTORS' PLANS AND COORDINATE ALL WORK AND MAINTAIN CLEAN PATHS FOR ALL CODE REQUIRED EXITS AT ALL THE PHASES OF CONSTRUCTION. THE SCHEDULE SHALL BE APPROVED BY THE OWNER AND ARCHITECT-ENGINEER OF THE RECORD PRIOR TO COMMENCING THE WORK. 19. APPROVAL BY THE INSPECTOR DOES NOT MEAN APPROVAL OR ALLOWABLE FAILURE TO COMPLY WITH THE PLANS AND SPECIFICATIONS. ANY DESIGN WHICH FAILS TO BE CLEAR OR IS AMBIGUOUS MUST BE REFERRED TO THE DESIGNER OR ENGINEER FOR INTERPRETATION OR CLARIFICATION. 20.VIBRATION EFFECTS OF MECHANICAL EQUIPMENT HAVE NOT BEEN CONSIDERED BY SEOR. 21.DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE INSTRUCTIONS OR REQUIREMENTS OF REGULATORY AGENCIES IS TO THE LATEST PRINTED EDITION OF EACH IN EFFECT AT THE DATE OF SUBMISSION OF BID UNLESS THE DOCUMENT DATE IS SHOWN. DETAILS ON SHEETS TITLED “TYPICAL DETAILS” APPLY TO SITUATIONS OCCURRING ON THE PROJECT THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY REFERENCED. SUCH DETAILS ARE NOT NOTED AT EACH LOCATION THAT THEY OCCUR. 22.TYPICAL AND SIMILAR DETAILS SHALL BE CONSIDERED WHERE THE CONDITIONS ARE NOT SPECIFICALLY DETAILED. RESPONSIBILITIES OF THE CONTRACTOR INCLUDE UNDERSTANDING THE EXTENT OF THE TYPICAL DETAILS AND THEIR APPLICATION PRIOR TO PERFORMING WORK. 23.SPECIFIC NOTES AND DETAILS ON DRAWINGS TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. IF CONFLICT OCCURS BETWEEN THE CONTRACT DRAWINGS AND THE PROJECT MANUAL, IMMEDIATELY NOTIFY ARCHITECT AND STRUCTURAL ENGINEER FOR RESOLUTION. NO WORK SHALL BE PERFORMED IN THE AREA OF QUESTION TILL THE CONFLICT IS RESOLVED. 24.THE STABILITY, AND INTEGRITY OF THE STRUCTURE ARE VERIFIED AS A WHOLE. PROJECT DOCUMENTS DO NOT INDICATE MEANS AND METHODS OF THE CONSTRUCTION. CONTRACTOR SHALL TAKE REQUIRED MEASURES TO ENSURE THE STABILITY AND INTEGRITY OF THE STRUCTURE CONSIDERING ALL FIELD CONDITIONS. NEW COMPONENTS THAT ARE ADDED FOR STABILITY AND ARE NOT PART OF THE FINAL CONSTRUCTION SHALL BE REMOVED PRIOR TO CONCLUDING THE WORK. 25.DURIG THE CONSTRUCTION, ALL TEMPORARY BRACING ELEMENTS REQUIRED TO RESIST WIND, SEISMIC, SOIL PRESSURE OR OTHER LATERAL LOADS, SHALL BE MAINTAINED UNTIL THE MAIN LATERAL FORCE RESISTING SYSTEMS OF THE BUILDING AND THEIR CONNECTIONS ARE COMPLETED. PROJECT OBSERVATION PROGRAMS AND VISITS PERFORMED BY ENGINEERS AND INSPECTORS SHALL NOT BE CONSIDERED AS APPROVAL OF CONSTRUCTION MEANS AND METHODS. STRUCTURAL OBSERVATIONS DO NOT CONSTITUTE QUALITY CONTROL, DO NOT GUARANTEE CONTRACTOR'S PERFORMANCE, AND SHALL NOT BE CONSIDERED AS SUPERVISION OF CONSTRUCTION. 26.CONTRACTOR IS SOLELY RESPONSIBLE FOR PROTECTION OF ALL STRUCTURAL, NONSTRUCTURAL, ARCHITECTURAL, FINISHING, ELECTRICAL AND MECHANICAL COMPONENTS WHICH ARE NOT DESIGNATED FOR DEMOLITION OR NEW CONSTRUCTION. ANY DAMAGES CAUSED BY THE CONTRACTOR OR SUBCONTRACTORS SHALL BE REPAIRED BY THE CONTRACTOR AT NO COSTS TO THE OWNER. 27.ALL MODIFICATIONS AND SUBSTITUTIONS SHALL BE SUBMITTED FOR APPROVAL. 28.THE CONTRACTOR SHALL VERIFY EXISTING CONCEALED AND VISIBLE CONDITIONS AND SHALL MAKE NECESSARY ADJUSTMENTS TO THE SYSTEMS AND COSTS DUE TO ACTUAL FIELD CONDITIONS. UNLESS SPECIFICALLY APPROVED BY THE OWNER, ARCHITECT AND STRUCTURAL ENGINEER OF THE RECORD, AFTER AWARDING THE PROJECT, NO ADDITIONAL COSTS TO THE OWNER OR ENGINEER ARE ACCEPTED DUE TO FIELD CONDITIONS. 29.STRUCTURAL DESIGN CAPACITIES PROVIDED ON THESE DRAWINGS ARE APPLICABLE AFTER THE ALL ELEMENTS AND THEIR CONNECTIONS ARE CONSTRUCTED AND FULLY CURED. WHERE CONSTRUCTION MATERIALS ARE PLACED ON CONSTRUCTED FLOORS AND ROOFS, MATERIALS SHALL BE DISTRIBUTED SUCH THAT THE DESIGN LIVE LOAD PER SQUARE FOOT IS NOT EXCEEDED AT ANY LOCATIONS. 30.EQUIPMENT ANCHORAGE TO THE STRUCTURE SHALL BE PROVIDED BY MANUFACTURER IN ACCORDANCE WITH STATE AND CITY CODES. 31.BRACING SYSTEMS USED FOR ATTACHMENTS SHALL HAVE CURRENT APPROVAL DOCUMENTS AND EVALUATION REPORT, WHICH CONFORM TO THE GOVERNING CODE, AND AUTHORITY REQUIREMENTS. 32.SUSPENDED EQUIPMENT SHALL BE SECURED WITH APPROVED LATERAL BRACING SYSTEM HAVING CURRENT APPROVAL DOCUMENTS AND EVALUATION REPORT. 33.UNLESS NOTES OTHERWISE, LOADS FROM ELECTRICAL, MECHANICAL, AND PLUMBING ATTACHMENTS SHALL BE SUPPORTED BY STRUCTURAL BEAMS. 34.INSTALL ALL MATERIALS AND PRODUCTS SPECIFIED OR SHOWN IN THESE DRAWINGS IN STRICT CONFORMANCE WITH THE MANUFACTURER'S WRITTEN RECOMMENDATIONS. 35.REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS NOT SHOWN ON STRUCTURAL DRAWINGS LAYOUT OF DOOR AND WINDOW OPENINGS IN STRUCTURAL WALLS, LOCATION AND EXTENT OF EXTERIOR WALL SYSTEM, LOCATION AND EXTENT OF NON-BEARING CMU WALLS AND LAYOUT OF OPENINGS THEREIN, LAYOUT OF SLOPES, CONCRETE CURBS, DEPRESSIONS, CHANGES IN LEVEL, CHAMFERS AND REVEALS, INSERTS FOR FINISH SYSTEMS, LAYOUT OF OPENINGS IN FLOORS AND ROOF AND SLAB EDGES,FRAMING, LAYOUT AND DETAILS STAIR SIZE AND LOCATION. 36.REFER TO ELECTRICAL, MECHANICAL, PLUMBING DRAWINGS FOR LOCATION AND SIZE OF PIPE SLEEVES, TRENCHES, AND OPENINGS THROUGH WALLS AND SLABS FOR DUCTWORK, LAYOUT, LOCATIONS AND EXTENT OF ANCHORAGE OF PIPING, ELECTRICAL CONDUITS AND DUCTWORK, TO STRUCTURE, LAYOUT, LOCATIONS, AND EXTENT OF EQUIPMENT ANCHORAGE TO STRUCTURE, EQUIPMENT PADS, AND REQUIREMENT WEIGHTS, LAYOUT, LOCATIONS, AND EXTENT OF ELECTRICAL CONDUITS, OUTLETS, AND BOXES IN CONCRETE SLABS AND WALLS. 37.UNLESS APPROVED BY THE ENGINEER, NO OPENING, HOLES, CUTS OR DISCONTINUITIES NOT SHOWN ON THE STRUCTURAL DRAWINGS AND EXTENDING INTO OR THROUGH STRUCTURAL ELEMENTS SHALL BE PERMITTED. ADDITIONAL DETAILING MAY BE REQUIRED AT THESE LOCATIONS. 38.ANY MODIFICATION TO THESE DRAWINGS OR DETAILS WITHOUT A WRITTEN APPROVAL FROM THE ENGINEER SHALL VOID THE ENGINEER’S RESPONSIBILITY FOR THE WHOLE STRUCTURE. IF ANY MODIFICATIONS ARE REQUIRED, IT SHALL BE REPORTED TO THE ENGINEER AND SHALL BE APPROVED PRIOR TO PERFORMING THE WORK. 39.DESIGN DATA DESIGN OF THE STRUCTURE IS IN ACCORDANCE WITH THE CALIFORNIA BUILDING CODE, 2022. UNLESS NOTED OTHERWISE ON THE DRAWINGS, THE DESIGN LOADS ARE AS TABLE LL-1. RESIDENTIAL AREAS RISK CATEGORY =II CODE LEVEL WIND DESIGN DATA ARE AS TABLE WIND-1. CODE LEVEL EARTHQUAKE DESIGN DATA ARE AS TABLE EQ-1. GENERAL NOTES LAP SPLICE LENGTH db GA P S H A L L N O T E X C E E D TH E S M A L L E R O F 1 / 2 LA P L E N G T H A N D 6 " REINFORCEMENT AS REQD.CONCRETE NOTE: BARS ARE REPMITTED TO BE IN CONTACT WITH EACH OTHER DE V E L O P M E N T L E N G T H PE R T A B L E SURFACE OF CONCRETE OR SECTION FROM WHICH DEVELOPMENT LENGTH IS MEASURED CO V E R O N B A R E X T E N T I O N FO R 9 0 ° H O O K A SECTION A SIDE COVER FOR 90° AND 180° HOOK DEVELOPMENT LENGTH AND COVER FOR HOOKS AND BAR EXTENSION 90° HOOK db 12 d b EX T E N S I O N 6d b B E N D DI A . 180° HOOK db 6d b B E N D DI A . 2 1/2", BUT NOT LESS THAN 4db EXTENSION HOOKS FOR REINFORCEMENT IN WALLS AND FOUNDATIONS 90° HOOK db 12 d b EX T E N S I O N 4d b B E N D DI A . 135° HOOK db 4d b B E N D DI A . 6db EXTEN S I O N HOOKS FOR STIRRUPS IN LINTELS FIGURE STANDARD HOOKS TABLE CONCOV-1. CONCRETE COVERAGE LOCATION VALUE CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" CONCRETE EXPOSED TO EARTH OR WEATHER: NO. 6 THROUGH NO. 18 BARS NO. 5 BARS, W31 OR D31 WIRE, AND SMALLER 2" 1 1/2" CONCRETE NOT EXPOSED WEATHER OR IN CONTACT WITH GROUND: SLAB, WALL, JOIST: NO. 14 AND NO. 18 BARS NO. 11 BARS AND SMALLER (*) BEAMS AND COLUMNS: PRIMARY REINFORCEMENT, TIES, STIRRUPS, SPIRALS SLAB-ON-GRADE 1 1/2" 1" 1 1/2" AT ONE-THIRD OF THE SLAB THICKNESS FROM THE TOP SIDE (*) CONCRETE COVER FOR THESE MEMBERS MAY NOT BE ADEQUATE FOR 2 HOURS OF FIRE RATING FRAMING LUMBER AND ENGINEERED WOOD PRODUCT 1.ALL WOOD OR WOOD BASED MATERIALS SHALL CONFORM TO THE FOLLOWING STANDARDS: 1.1. ALL STRUCTURAL WOOD LUMBERS AND TIMBERS SHALL BE DOUGLAS FIR-LARCH CONFORMING TO THE REQUIREMENTS OF WWPA OR WCLIB UNLESSE NOTE OTHERWISE ON THESE DRAWINGS. 1.2. STRUCTURAL ALL STRUCTURAL PLYWOOD SHALL BE DOUGLAS FIR LARCH AND SHALL CONFORM TO THE REQUIREMENTS OF USDOC PS 1—09 OR MORE RECENT EDITION. 1.3. ALL STRUCTURAL PANELS SHALL CONFORM TO THE REQUIREMENTS OF USDOC PS 2—10 OR MORE RECENT EDITION. 1.4. ALL STRUCTUR AL SAWN LUMBER INCLUDING END-JOINTED OR EDGE-GLUED LUMBER , MACHINE STRESS-RATED OR MACHINE-EVALUATED LUMBER, SHALL BE IDENTIFIED BY THE GRADE MARK OF A LUMBER GRADING OR INSPECTION AGENCY THAT HAS BEEN APPROVED BY AN ACCREDITATION ODY BODY THAT COMPLIES WITH DOC PS 20-05 OR MORE RECENT EDITION. 1.5. ENGINEERED WOOD RIM BOAR DS SHALL CONFORM TO ANSI/APA PRR 410-2021 OR MORE RECENT EDITION. 2.UNLESS NOTED OTHERWISE, ALL STRUCTURAL LUMBER SHALL BE DOUGLAS FIR-LARCH CONFORMING TO THE LATEST EDITION OF NDS FOR THE TABLE FL-1. 3.MEMBER SIZES SHOWN ARE NOMINAL UNLESS NOTED OTHERWISE. 4.ALL CONNECTORS AND FASTENERS SHALL COMPLY WITH THE APPLICABLE PROVISIONS AND TABLES OF SECTIONS 2304.10.2 THROUGH 2304.10.7 OF CBC 2022. 5.ALL WOOD AND WOOD BASED MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF AMERICAN WOOD PROTECTION ASSOCIATION (AWPA) U1 FOR THE USE CATEGORY OF THE COMPONENT. 6.ANY PRESERVATIVE-TREATED WOOD MEMBERS THAT ARE ALTERED, CUT, DRILLED OR NOTCHED ON THE FIELD, SHALL BE RETREADED AS SPECIFIED BY MANUFACTURER AND APPROVED BY LOCAL AUTHORITIES. IF NO WRITTEN RECOMMENDATIONS ARE PROVIDED, ALL DRILLED HOLES AND CUT ENDS NEED TO BE TREATED WITH A PRESERVATIVE, TO CONFORM AMERICAN WOOD PROTECTION ASSOCIATION (AWPA) STANDARD M4. 7.FASTENERS SHALL CONFORM TO THE REQUIREMENTS SPECIFIED ON THESE DRAWINGS. FASTENERS SHALL NOT BE PLACED CLOSER THAN THE SPECIFIED EDGE AND END DISTANCES. SPACING OF THE FASTENERS SHALL BE AS SPECIFIED. 8.FASTENERS HEAD SHALL BE DRIVEN FLUSH WITH THE SURFACES AND SHALL NOT FRACTURE OR DAMAGE THE LUMBER OR SHEATHING SURFACES. 9.PROVIDE LEAD HOLE 40%-70% OF THREADED SHANK DIA. AND FULL DIA. FOR SMOOTH SHANK PORTION OF LAG BOLTS. THREADED CONNECTORS SUCH AS LAG SCREWS AND WOOD SCREWS SHALL BE INSTALLED BY TURNING WIDTH A WRENCH. HAMMER DRIVEN SCREWS SHALL NOT BE PERMITTED. 10.ALL BOLT HOLES, OTHER THAN LAG BOLT HOLES, SHALL BE DRILLED A MINIMUM OF 1/32" TO A MAXIMUM OF 1/16" LARGER THAN BOLT DIAMETER. HOLES SHALL BE ACCURATELY ALIGNED IN THE MAIN MEMBERS AND SIDE PLATES. BOLTS SHALL NOT BE FORCIBLY DRIVEN. INSPECTOR SHALL VERIFY ALL HOLES AT JOB SITE 11.PROVIDE LATERAL SUPPORT FOR THE TOP OF INTERIOR NON-BEARING WALLS WHEN MANUFACTURED TRUSSES ARE USED. 12.ALL ROOF/FLOOR AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED BOX. GALVANIZED NAILS SHALL BE HOT-DIPPED OR TUMBLED. NAIL GUNS USING "CLIPPED HEAD" OR SINKER NAILS ARE NOT ACCEPTABLE. 13.ROOF/FLOOR NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. FLOOR SHALL HAVE TONGUE AND GROOVE OR BLOCKED PANEL EDGES. 14.STUCCO SHEAR WALLS SHALL UTILIZE FURRING, GALVANIZED NAILS (HAVING A MINIMUM 11 GA., 1-1/2" LONG, 7/16" DIAMETER HEAD, AND FURRED OUT A MIN OF 1/4") TO ATTACH THE LATH TO THE STUDS. (TABLE 2306.3(3)). 15.SHOP WELDS SHALL BE PERFORMED WITH LICENSED FABRICATORS. 16.STRUCTURAL WOOD SHEAR WALLS SHALL BE COVERED WITH MINIMUM TWO LAYERS GRADE D FELT UNDERLAY PRIOR TO PLACING FINISH MATERIAL. 17.HOLD-DOWN CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE APPROVED PLATE WASHERS. HOLD-DOWNS SHALL BE FINGER TIGHT AND 1/2 WRENCH TURN JUST PRIOR TO COVERING THE WALL FRAMING. CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE STEEL PLATE WASHERS ON THE POST ON THE OPPOSITE SIDE OF THE ANCHORAGE DEVICE. PLATE SIZE SHALL BE A MINIMUM OF 0.25 IN. BY 3 IN. BY 3 IN. 18.MAXIMUM MOISTURE CONTENT FOR FRAMING LUMBER INCLUDING PRESERVATIVE-TREATED WOOD SHALL NOT EXCEED 19% AT THE TIME OF PLYWOOD OR GYPBOARD COVERAGE INSTALLATION. 19.UNLESS NOTED OTHERWISE, FRAMING LUMBER USED FOR COMPLETELY NEW CONSTRUCTIONS SHELL BE STAMPED AS KILN-DRIED (KD), HEAT TREATED (KD-HT), SURFACE-DRY (S-DRY) LUMBER OR MC-15 LUMBER. (S-DRY) LUMBER SHALL NOT BE PERMITTED TO BE USED IN EXISTING CONSTRUCTION OR FOR THE NEW CONSTRUCTIONS THAT ARE ATTACHED TO EXISTING CONSTRUCTION. 20.TOP AND BOTTOM PLATES OF WALLS SHALL BE KLIN DRIED FOR BUILDINGS MORE THAN TWO STORIES. 21.PROVIDE DOUBLE JOISTS OR 4x BEAM GIRDERS UNDER PARALLEL PARTITIONS. STITCH NAIL THE DOUBLE SWAN JOISTS WITH 16D NAILS SPACED NOT MORE THAN THE LESSER OF JOISTS DEPTH AND 12 IN. NAILS SHALL BE STAGGERED AT THE TOP AND BOTTOM. 22.PROVIDE DOUBLE 2X OR 4X BLOCKING UNDER WALLS OR PARTITIONS PERPENDICULAR TO THE JOISTS. 23.UNO, ALL DISCONTINUOUS WALLS SHALL BE SUPPORTED ON BEAMS, DOUBLE JOISTS OR SOLID BLOCKING WITH THE WIDTH NOT LESS THAN THE WIDTH OF THE SUPPORTED WALL. 24.ALL WOOD BOLTS AND LAG SCREWS SHALL CONFORM TO REQUIREMENTS OF ANSI/ASME B18.2.1, WOOD SCREWS SHALL CONFORM TO THE REQUIREMENTS OF ANSI/ASME B18.6.1, AND NAILS SHALL CONFORM TO THE REQUIREMENTS OF ASTM F1667. 25.ALL NAILS SHALL CONFORM TO THE REQUIREMENTS OF ASTM F1667. UNLESS OTHERWISE NOTED ON THESE DRAWINGS, ALL NAILS SHALL BE COMMON WIRE NAILS, AND NUMBER OF CONNECTING NAILS AT EACH LOCATION SHALL NOT BE LESS THAN THE SPECIFIED NUMBERS ON THESE DRAWINGS. ALL NAILS THAT ARE EXPOSED TO WEATHER OR MOISTURE SHALL BE HOT-DIPPED GALVANIZED COMMON NAILS THAT CONFORMS TO ASTM A153 CLASS D. NAILS SHALL CONFORM TO THE REQUIREMENTS SPECIFIED IN TABLE FL-2. NAILS. 26.ALL HORIZONTAL JOINTS OCCURRING IN BRACED / SHEAR WALL PANELS SHALL OCCUR OVER BLOCKING EQUAL IN SIZE TO THE STUDDING. 27.ALL STEEL BOLT AND RODS SHALL CONFORM TO ASTM A307 OR ASTM F1554 GR. 36. ALL BOLT HOLES SIZES SHALL INSPECTED AND VERIFIED AT JOB SITE. 28. ALL BOLTS, NUTS, AND LAG SCREWS THAT BEAR ON WOOD MATERIALS SHALL HAVE STANDARD CUT WASHERS UNDER THE BOLT HEAD AND NUTS. NOT MORE THAN 24 HRS PRIOR TO COVERING THE BOLTS, ALL BOLTS SHALL BE RETIGHTENED. 29. PROVIDE FULL HEIGHT SOLID BLOCKING AT THE ENDS, ALL JOISTS, BEAMS AND RAFTERS SHALL NOT BE JOISTS, BEAMS AND RAFTERS. INTERMEDIATE FULL BLOCKING OF SHALL NOT BE SPACED MORE THAN 8 FT FROM THE ADJACENT BLOCK (8 FT OC MAX.) . 30. PROVIDE ONE INTERMEDIATE AND END FULL HEIGHT SOLID BLOCKING ALONG ALL THE JOISTS BEAMS AND RAFTERS WITH SPANS GREATER THAN 8 FT BUT LESS THAN 16 FT. THE INTERMEDIATE BLOCKING SHALL BE SPACED MID-SPAN OF THE JOIST. 31. PROVIDE TWO INTERMEDIATE AND END FULL HEIGHT SOLID BLOCKING ALONG ALL THE JOISTS BEAMS AND RAFTERS WITH SPANS GREATER THAN 16 FT BUT LESS THAN 24 FT. THE INTERMEDIATE BLOCKING SHALL BE SPACED 1/3 OF THE SPAN FROM EACH END. 32. PROVIDE THREE INTERMEDIATE AND END FULL HEIGHT SOLID BLOCKING ALONG ALL THE JOISTS BEAMS AND RAFTERS WITH SPANS GREATER THAN 24 FT. THE INTERMEDIATE BLOCKING SHALL BE SPACED NOT MORE THAN 8 FT ALONG THE SPAN FROM EACH OTHER. 33. APPROVED METAL BRIDGING THAT HAVE CURRENT ICC ES EVALUATION MAY BE USED INSTEAD OF SOLID BLOCKING FOR FULL HEIGHT INTERMEDIATE SUPPORTS. 34. DO NOT SUSPEND CEILINGS, SOFFITS, SPRINKLERS, PIPING, MECHANICAL DUCTS, NOR ANY OTHER ELEMENT FROM 2X4 ROOF FRAMING UNLESS SPECIFICALLY DETAILED. 35. CUTTING, NOTCHING, AND BORING OF WOOD FRAMING MEMBERS SHALL BE IN ACCORDANCE WITH CBC SECTION 2308.5.9. AND AS SHOWN ON THESE DRAWINGS. 36. FIRE-RETARDANT-TREATED WOOD IS ANY WOOD PRODUCT THAT, WHEN IMPREGNATED WITH CHEMICALS BY A PRESSURE PROCESS OR OTHER MEANS DURING MANUFACTURE, SHALL HAVE, WHEN TESTED IN ACCORDANCE WITH ASTM E84 OR UL 723, A LISTED FLAME SPREAD INDEX OF 25 OR LESS AND SHOW NO EVIDENCE OF SIGNIFICANT PROGRESSIVE COMBUSTION WHEN THE TEST IS CONTINUED FOR AN ADDITIONAL 20-MINUTE PERIOD. ADDITIONALLY, THE FLAME FRONT SHALL NOT PROGRESS MORE THAN 10-1/2 FEET BEYOND THE CENTERLINE OF THE BURNERS AT ANY TIME DURING THE TEST. 37. SQUASH BLOCKS WITH THE SAME WIDTH SHALL BE PROVIDED UNDER ALL BEARING POINT LOADS FROM ABOVE TO THE TOP OF THE TOP PLATES BELOW AT FLOOR LEVELS. 38. LATERAL BRACING OF WEB MEMBERS IN TRUSSES SHALL BE END ON AN EXTERIOR SHEAR/BRACING WALL. 39. BLOCKING REQUIRED FOR LIGHT FEATURES, CABINETS, HANDRAILS, GUARDRAILS TOWEL BARS OR OTHER LIGHT ATTACHMENTS ARE NOT SHOWN ON THESE DRAWINGS AND SHALL BE PROVIDED BY GC AS REQUIRED BASED ON ARCHITECTURAL, AND MEP DRAWINGS. 40. FIREBLOCKS NOT SMALLER THAN 2 IN. NOMINAL SHALL BE PROVIDED TO CUT OFF ALL HORIZONTAL AND VERTICAL DRAFTS BETWEEN TWO STORIES AND ROOF ATTIC SPACES. FIREBLOCKS SHALL BE PROVIDED AT STUD WALLS AT FURRED SOFFITS, CEILING AND FLOOR LEVELS, . BETWEEN STAIR STRINGERS AT TOP AND BOTTOM OF RUN AND BETWEEN STUDS IN A WALL PARALLEL AND ADJOINING RUN OF STAIRS, AROUND TOP, BOTTOM, SIDES AND ENDS OF SLIDING POCKET DOOR. 41. FURRING SHALL BE PROVIDED TO ALIGN SHEAR WALLS WITH ALL OTHER WALLS. 42. BEARING WALLS SHALL BE SHEATHED ON NOT LESS THAN ONE SIDE OR BRIDGING SHALL BE INSTALLED NOT GREATER THAN 4 FEET APART MEASURED VERTICALLY FROM EITHER END OF THE STUD. 2x BLK'G SHALL BE PROVIDED AT PLYWD JOINTS FOR ALL WALLS. 43. ALL STEEL CONNECTORS INCLUDING BOLTS, SCREWS AND NAILS USED IN EXTERIOR STRUCTURE OR EXPOSED TO WEATHER SHALL BE STAINLESS STEEL OR HOT-DIP GALVANIZED. FASTENERS IN PRESERVATIVE TREATED WOOD OR FIRE RETARDANT TREATED WOOD SHALL BE OF HOT DIPPED ZINC COATED GALVANIZED STEEL OR STAINLESS STEEL. ENGINEERED WOOD PRODUCTS 1.ALL STRUCTURAL GLUED-LAMINATED TIMBERS AND STRUCTURAL COMPOSITE LUMBERS AND ORIENTED STRAND BOARDS SHALL HAVE A CURRENT ICC ES EVALUATION REPORT AND AS A MINIMUM SHALL CONFORM TO REQUIREMENTS SPECIFIED IN TABLE FL-3 : 2.GLUED-LAMINATED TIMBERS SHALL BE MANUFACTURED AND IDENTIFIED AS REQUIRED IN AMERICAN INSTITUTE OF TIMBER CONSTRUCTION, ANSI/AITC A 190.1 AND AMERICAN SOCIETY FOR TESTING AND MATERIALS ASTM D3737. 3.STRUCTURAL GLUED LAMINATED TIMBER SHALL BE MADE OF 1-1/2 IN. DOUGLAS FIR LAMINATION WITH 24-F COMBINATION AS SPECIFIED IN AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (AITC). 4.UNLESS NOTED OTHERWISE, ALL GLUED LAMINATED TIMBERS SHALL BE GRADE INDUSTRIAL DATE: P.M.: DRAWN BY: JOB NO.: 30211 Avenida de las Banderas, Suite 200, Rancho Santa Margarita, California, 92688 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D E SI GN B U I L D CNI UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT REV DATE REMARKS M.A. ISSUED FOR PERMIT12.17.20240 07.13.2025 20241149 ISSUED PER CITY PERMIT07.13.20251 S0.01 CONSTRUCTION NOTES 07/15/2025 EXP. 06-30-2026 1.STRUCTURAL OBSERVATION IS REQUIRED FOR THIS PROJECT IN ACCORDANCE WITH SECTION 1704.6 OF THE CBC 2022. STRUCTURAL OBSERVATION IS THE VISUAL OBSERVATION OF THE STRUCTURAL SYSTEM BY A LICENSED DESIGN PROFESSIONAL FOR GENERAL CONFORMANCE TO THE APPROVED CONSTRUCTION DOCUMENTS. 2.STRUCTURAL OBSERVATIONS DO NOT CONSTITUTE QUALITY CONTROL, DO NOT GUARANTEE CONTRACTOR'S PERFORMANCE, AND SHALL NOT BE CONSIDERED AS SUPERVISION OF CONSTRUCTION. 3.THE OWNER OR QWNER'S REPRESENTATIVE SHALL COORDINATE AND CALL FOR A MEETING BETWEEN THE ENGINEER OR ARCHITECT RESPONSIBLE FOR THE STRUCTURAL DESIGN, STRUCTURAL OBSERVER, CONTRACTOR, AFFECTED SUBCONTRACTORS AND DEPUTY INSPECTORS. THE PURPOSE OF THE MEETING SHALL BE TO IDENTIFY THE MAJOR STRUCTURAL ELEMENTS AND CONNECTIONS THAT AFFECT THE VERTICAL AND LATERAL LOAD SYSTEMS OF THE STRUCTURE AND TO REVIEW SCHEDULING OF THE REQUIRED OBSERVATIONS. 4.STRUCTURAL OBSERVATION DOES NOT WAIVE THE RESPONSIBILITY FOR THE REQUIRED INSPECTIONS BY THE CITY OF SANTA ANA. 5.THE OWNER SHALL EMPLOY A LICENSED DESIGN PROFESSIONAL TO PERFORM STRUCTURAL OBSERVATION SITE VISITS, AND TO ISSUE ALL STRUCTURAL OBSERVATION REPORTS. 6.THE STRUCTURAL OBSERVER SHALL PREPARE A STRUCTURAL OBSERVATION REPORT FOR EACH STAGE OF CONSTRUCTION OBSERVED. THE CITY OF SANTA ANA STRUCTURAL OBSERVATION REPORT” FORM, OR A SIMILARLY FORMATTED REPORT, SHALL BE USED FOR ALL STRUCTURAL OBSERVATION REPORT. 7.IF THE CITY’S FORM IS NOT USED, REPORTS SHALL BE ON STRUCTURAL OBSERVER’S LETTERHEAD, STATE SITE ADDRESS, PLAN CHECK & PERMIT NUMBERS, STAGES & ELEMENTS OBSERVED, DATE OBSERVED, & COMPLETE CONTACT INFORMATION FOR STRUCTURAL OBSERVER. 8.ALL STRUCTURAL OBSERVATION REPORTS, REGARDLESS OF FORM USED, SHALL INCLUDE THE LICENSE STAMP & SIGNATURE OF THE STRUCTURAL OBSERVER RESPONSIBLE FOR THE PROJECT. 9.EACH STRUCTURAL OBSERVATION REPORT SHALL BE GIVEN TO THE OWNER OR OWNER’S REPRESENTATIVE, PROJECT CONTRACTOR, AND THE BUILDING INSPECTOR. 10.THE CONTRACTOR SHALL RESOLVE ALL DEFICIENCIES & THE FINAL STRUCTURAL OBSERVATION REPORT ISSUED PRIOR TO FINAL INSPECTION OR ACCEPTANCE OF STRUCTURAL WORK BY THE BUILDING INSPECTOR. 11.THE LICENSED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL PREPARE ALL CONSTRUCTION DOCUMENT CHANGES RELATING TO THE STRUCTURAL SYSTEMS. REVIEW & APPROVAL OF SUCH CHANGES BY THE CHIEF BUILDING OFFICIAL, OR DESIGNEE, SHALL BE OBTAIN BY THE DESIGN PROFESSIONAL AND/OR CONTRACTOR PRIOR TO INSTALLATION AND/OR CONSTRUCTION OF SAID CHANGES. GYPSUM BOARD AND EXPANDED METAL OR WOVEN WIRE LATH AND PORTLAND CEMENT PLASTER (STUCCO) NOTES LATHING AND FURRING FOR CEMENT PLASTER EXTERIOR PLASTER STRUCTURAL OBSERVATION SPECIAL INSPECTION Special Inspection Program and Designation of Special Inspectors 601 N. Ross Street, Santa Ana, CA 92701 P.O. Box 4048, Santa Ana, CA 92702-4048 www.ocpublicworks.com 714.667.8888 | myOCeServices.ocgov.com □ Concrete (Design Mix, Form Work, Placement, etc*.) □ Erection of Pre-Cast Concrete Members □ Bolts Installed in Concrete □ Reinforcing Steel and Pre-Stressing Steel Tendons □ StructuralWelding/Rebar Welding □ High-Strength Bolting/Material Verification □ Steel Frame Joint Details □ All Masonry Construction □ Sprayed Fire-Resistive Materials □ Shotcrete (Curing Temperature, Design Mix, Placement, Strength etc. per table 1705.3) □ Soils (Excavation, Fill, etc. per table 1705.6) □ Smoke-Control System □ Driven Piles per Table 1705.7 □ Cast in Place Piers per Table 1705.8 □ Mastic and Intumescent Fire-Resistant Coatings □ Exterior Insulation and Finish Systems (EIFS) □Wood for High-Load Diaphragms □ Others □ Others □ Others □ Others SPECIAL INSPECTIONS (Only checked items are required) INSPECTION ITEMS SPECIAL INSPECTORS(S) NAME,PHONE NUMBER,REGISTRATION# DECLARATION BY OWNER OR ARCHITECT/ENGINEER OF RECORD: I, the □ Owner □ Engineer or □ Architect of record,declare that the above listed Special Inspector(s) is/are hired by me. Print Name Signature Date *NO SPECIAL INSPECTION REQUIRED IF CONCRETE TRUCK MIX TICKET IS PROVIDED. Structural Observation Program Designation of Structural Observation PROJECT ADDRESS: _________________________________________ PERMIT APPL. NO.__________ Description of Work: ____________________________________________________________________ Owner: _______________________ Architect: ________________________ Engineer: _______________ STRUCTURAL OBSERVATION (Only checked items are required) Firm or individual to be responsible for the Structural Observation: Name:Phone: ( FOUNDATION Footing, Stem Walls, Piers Mat Foundation Caisson, Piles, Grade Beams Stepp’g/Retaining Foundation, Hillside Special Anchors WALL Concrete Masonry Wood Others: The structure is classified as Occupancy Category III or IV. The Height of the structure is greater then 75 feet (22,860 mm) above the base. The structure is assigned to Seismic Design Category E, is classified as Occupancy Category I or II. DECLARATION BY OWNER I, the Owner of the project, declare that the above listed firm or individual is hired by me to be the Structural Observer. )Calif. Registration: FRAME Steel Moment Frame Steel Braced Frame DIAPHRAGM Concrete Steel Deck Concrete Moment Frame Masonry Wall Frame Others: Signature ______________________________Date _________________ Declaration by Engineer or Architect of Record (required if different from the listed Structural Observer) I, the Engineer or Architect of record for the project, declare that the above listed firm or individual is designated by me to be responsible for the Structural Observation. Signature ______________________________ 300 N. Flower Street, Santa Ana, CA 92703 P.O. Box 4048, Santa Ana, CA 92702-4048 Revised 02/2017 Date __________________ www.ocpublicworks.com P: 714.667.8888 I F: 714.667.7575 ocpCustomerCare@ocpw.ocgov.com Wood 606 S VAN NESS AVE, SANTA ANA, CA 92701 NEW DETACHED ADU GYPSUM BOARD 1.AN APPROVED AGENCY, RETAINED BY OWNER AND SATISFACTORY TO STRUCTURAL ENGINEER AND GOVERNING CODE AUTHORITIES, SHALL PERFORM SPECIAL INSPECTIONS AND TESTS REQUIRED BY THE CONTRACT AND APPLICABLE CODE. THESE SPECIAL INSPECTIONS AND TESTS ARE IN ADDITION TO THE INSPECTIONS REQUIRED BY CBC SECTION 110 “INSPECTIONS”. 2.APPROVED AGENCY SHALL KEEP RECORDS OF ALL SPECIAL INSPECTIONS AND TESTS AND SHALL FURNISH REPORTS OF SPECIAL INSPECTIONS AND TESTS TO THE GOVERNING CODE AUTHORITY AND THE STRUCTURAL ENGINEER. REPORTS SHALL INDICATE WHETHER THE WORK INSPECTED OR TESTED WAS OR WAS NOT COMPLETED IN CONFORMANCE TO APPROVED CONSTRUCTION DOCUMENTS. DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION. IF NOT CORRECTED, THE DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE GOVERNING CODE AUTHORITY AND THE STRUCTURAL ENGINEER PRIOR TO THE COMPLETION OF THAT PHASE OF WORK. A FINAL REPORT DOCUMENTING REQUIRED SPECIAL INSPECTIONS AND TESTS, AND CORRECTION OF DISCREPANCIES, SHALL BE SUBMITTED UPON COMPLETION OF THAT PHASE OF WORK. 3.WHERE FABRICATION OF STRUCTURAL, LOAD-BEARING OR LATERAL LOAD-RESISTING MEMBERS OR ASSEMBLIES IS BEING CONDUCTED ON THE PREMISES OF A FABRICATOR’S SHOP, SPECIAL INSPECTION OF THE FABRICATED ITEMS SHALL BE PERFORMED DURING FABRICATION. SPECIAL INSPECTIONS DURING FABRICATION ARE NOT REQUIRED WHERE WORK IS DONE ON THE PREMISES OF A FABRICATOR REGISTERED AND APPROVED BY THE GOVERNING CODE AUTHORITY TO PERFORM SUCH WORK WITHOUT SPECIAL INSPECTION. FABRICATOR APPROVAL SHALL BE IN ACCORDANCE TO CBC SECTION 1704.2.5.1. ACCORDING TO 1704A.2.5.1 FABRICATOR APPROVAL IS NOT PERMITTED BY DSA-SS, DSA-SS/CC, OR OSHPD. 4.EACH CONTRACTOR RESPONSIBLE FOR THE CONSTRUCTION OF A MAIN WIND OR SEISMIC FORCE RESISTING SYSTEM, DESIGNATED SEISMIC SYSTEM, OR A WIND OR SEISMIC FORCE-RESISTING COMPONENT LISTED IN THE STATEMENT OF SPECIAL INSPECTION SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE GOVERNING CODE AUTHORITY AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON THE SYSTEM OR COMPONENT. THE CONTRACTOR’S STATEMENT OF RESPONSIBILITY SHALL CONTAIN ACKNOWLEDGEMENT OF AWARENESS OF THE SPECIAL REQUIREMENTS OF INSPECTION. 5.CONTRACTOR SHALL SUBMIT MATERIAL CERTIFICATION OR LABORATORY TEST REPORTS CERTIFYING MATERIALS ARE OF IDENTIFIABLE TESTED STOCK, COMPLYING WITH PROJECT SPECIFICATIONS, TO OWNER, APPROVED AGENCY, STRUCTURAL ENGINEER AND, UPON REQUEST, TO GOVERNING CODE AUTHORITY. IF LABORATORY TEST REPORTS CANNOT BE MADE AVAILABLE, APPROVED AGENCY WILL PERFORM TESTS AS DIRECTED BY STRUCTURAL ENGINEER. CONTRACTOR SHALL PAY FOR COSTS RELATED TO TESTS AND INSPECTIONS OF UNIDENTIFIABLE MATERIALS, MATERIALS FURNISHED WITHOUT LABORATORY TEST REPORTS, MATERIALS FOUND DEFICIENT AFTER INITIAL TESTS AND INSPECTIONS, AND/OR MATERIALS REPLACING DEFICIENT MATERIALS. 6.APPROVED AGENCY SHALL SUBMIT MATERIAL TEST REPORTS INDICATING WHETHER TESTED MATERIALS ARE IN COMPLIANCE OR NONCOMPLIANCE WITH CONTRACT DOCUMENTS TO OWNER, CONTRACTOR, STRUCTURAL ENGINEER AND, UPON REQUEST, TO GOVERNING CODE AUTHORITY. 7.APPROVED AGENCY SHALL PERFORM SPECIAL INSPECTIONS IN ACCORDANCE WITH CBC SECTION 1705, SECTION 1705A “REQUIRED SPECIAL INSPECTIONS AND TESTS” AND WITH THESE DRAWINGS FOR THE FOLLOWING WORK. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL TEST AND INSPECTION REQUIREMENTS. 7.1.SOILS: SPECIAL INSPECTIONS AND TESTS OF EXISTING SITE SOIL CONDITIONS, FILL PLACEMENT AND LOAD-BEARING REQUIREMENTS SHALL BE PERFORMED IN ACCORDANCE WITH TABLE 1. THE APPROVED GEOTECHNICAL REPORT AND THE CONSTRUCTION DOCUMENTS SHALL BE USED TO DETERMINE COMPLIANCE. 7.1.1.DURING FILL PLACEMENT THE APPROVED AGENCY SHALL VERIFY THAT PROPER MATERIALS AND PROCEDURES ARE USED IN ACCORDANCE WITH THE PROVISIONS OF THE APPROVED GEOTECHNICAL REPORT. 8.APPROVED AGENCY SHALL PERFORM SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE IN ACCORDANCE WITH CBC SECTION 1705.12 FOR THE FOLLOWING WORK. 8.1.STRUCTURAL WOOD: CONTINUOUS SPECIAL INSPECTION IS REQUIRED DURING FIELD GLUING OPERATIONS OF ELEMENTS OF THE SFRS. 8.1.1.PERIODIC INSPECTION IS REQUIRED FOR NAILING, BOLTING, ANCHORING AND OTHER FASTENING OF ELEMENTS OF THE SFRS, INCLUDING WOOD SHEAR WALLS, WOOD DIAPHRAGMS, DRAG-STRUTS, BRACES, SHEAR PANELS AND HOLD-DOWNS. 8.1.2.SPECIAL INSPECTION IS REQUIRED FOR WOOD SHEAR WALLS, SHEAR PANELS AND DIAPHRAGMS, INCLUDING NAILING, BOLTING, ANCHORING AND OTHER FASTENING TO OTHER COMPONENTS OF THE SFRS, WHERE FASTENER SPACING IS OF THE SHEATHING AT EDGES OR BOUNDARIES IS 4 IN. OR LESS. 8.2.SPECIAL INSPECTIONS ARE NOT REQUIRED FOR COLD-FORMED STEEL LIGHT-FRAME SHEAR WALLS AND DIAPHRAGMS, INCLUDING SCREW INSTALLATION, BOLTING, ANCHORING AND OTHER FASTENING TO COMPONENTS OF THE SEISMIC FORCE-RESISTING SYSTEM, WHERE EITHER OF THE FOLLOWING APPLIES: 8.2.1.THE SHEATHING IS GYPSUM BOARD OR FIBERBOARD. 8.2.2.THE SHEATHING IS WOOD STRUCTURAL PANEL OR STEEL SHEETS ON ONLY ONE SIDE OF THE SHEAR WALL, SHEAR PANEL OR DIAPHRAGM ASSEMBLY AND THE FASTENER SPACINGS AT THE EDGES ARE 4 IN. OR LESS. 8.3.ARCHITECTURAL COMPONENTS: PERIODIC SPECIAL INSPECTION IS REQUIRED FOR THE ERECTION AND FASTENING OF EXTERIOR CLADDING, INTERIOR AND EXTERIOR NONBEARING WALLS AND INTERIOR AND EXTERIOR VENEER. 8.3.1.PERIODIC SPECIAL INSPECTION IS NOT REQUIRED FOR THE FOLLOWING: 8.3.2.EXTERIOR CLADDING, INTERIOR AND EXTERIOR NONBEARING WALLS AND INTERIOR AND EXTERIOR VENEER 30 FEET OR LESS IN HEIGHT ABOVE GRADE OR WALKING SURFACE. 8.3.3.EXTERIOR CLADDING AND INTERIOR AND EXTERIOR VENEER WEIGHING 5 PSF OR LESS. 8.3.4.INTERIOR NONBEARING WALLS WEIGHING 15 PSF OR LESS. 9.CONTINUOUS SPECIAL INSPECTION BY A REGISTERED DEPUTY INSPECTOR IS REQUIRED FOR FIELD WELDING, POST-INSTALLED ADHESIVE ANCHORS INSTALLED HORIZONTALLY OR UPWARDLY INCLINED TO RESIST SUSTAINED TENSION LOADS, SHOTCRETE PLACEMENT, CONCRETE STRENGTH f'c > 2500psi, SPRAYED-ON FIREPROOFING, ENGINEERED MASONRY, HIGH-LIFT GROUTING, HIGH LOAD DIAPHRAGMS, SPECIAL MOMENT-RESISTING CONCRETE FRAMES, AND HELICAL PILE FOUNDATION. 10.SPECIAL INSPECTORS OR INSPECTION AGENCIES SHALL SUBMIT A SIGNED FINAL REPORT TO THE BUILDING DIVISION STATING THAT ALL ITEMS REQUIRING SPECIAL INSPECTION AND TESTING WERE FULFILLED AND REPORTED AND, TO THE BEST OF THEIR KNOWLEDGE, IN CONFORMANCE WITH THE APPROVED DESIGN DRAWINGS, SPECIFICATIONS, APPROVED CHANGE ORDERS AND THE APPLICABLE PROVISIONS OF THE CBC ITEMS NOT IN CONFORMANCE, UNRESOLVED ITEMS OR ANY DISCREPANCIES IN INSPECTION COVERAGE (I.E. MISSED INSPECTIONS, PERIODIC INSPECTIONS WHEN CONTINUOUS WAS REQUIRED, ETC.) SHOULD BE SPECIFICALLY ITEMIZED IN THIS REPORT. ALTERNATE FORMS MAY BE APPROVED BY THE BUILDING OFFICIALS. THE FINAL REPORT SHALL BE SUBMITTED AT THE SITE WITHIN SEVEN (7) DAYS OF COMPLETION OF THE JOB. 11.EMPLOYMENT OF SPECIAL INSPECTION IS THE DIRECT RESPONSIBILITY OF THE OWNER, OR THE ENGINEER/ARCHITECT OF RECORD ACTING AS THE OWNER'S REPRESENTATIVE. SPECIAL INSPECTOR SHALL BE ONE OF THOSE AS PRESCRIBED IN SEC. 1704. 1.EXPANDED METAL OR WOVEN WIRE LATH AND PORTLAND CEMENT PLASTER SHALL CONFORM TO THE FOLLOWIG: 1.1.EXPANDED METAL OR WOVEN WIRE LATH AND PORTLAND CEMENT SHALL CONFORM TO ASTM C847,ASTM C1032, AND ASTM C150 AND SHALL BE INSTALLED IN ACCORDANCE WITH ASTM C926 AND ASTM C1063.METAL LATH AND LATH ATTACHMENTS SHALL BE OF CORROSION - RESISTANT MATERIAL.. 1.2.FASTENER TO STUDS,TOP AND BOTTOM PLATES, AND BLOCKING SHALL BE 0.120" NAIL X 1-½” LONG, 7/16" HEAD OR NO. 16 GAGE GALV. STAPLE, 7/8" LEGS. STAPLES SHALL HAVE A MINIMUM CROWN WIDTH OF 7/16", MEASURED OUTSIDE THE LEGS, AND SHALL BE INSTALLED WITH THEIR CROWNS PARALLEL TO THE LONG DIMENSION OF THE FRAMING MEMBERS. STAPLES FOR THE ATTACHMENT OF GYPSUM LATH AND WOVEN-WIRE LATH SHALL HAVE A MINIMUM CROWN WIDTH OF 3/4", MEASURED OUTSIDE THE LEGS. 2.ALL WALLS,FLOOR,CIELING AND ROOF GYPSUM BOARD SHALL BE AT LEAST 1/2" THICK (UNO ON ARCH. DWG.) AND CONFORM TO THE FOLLOWING REQUIREMENTS: 2.1.GYPSUM WALLBOARD SHALL CONFORM TO ASTM C 1396 AND SHALL BE INSTALLED IN ACCORDANCE WITH ASTM C 840. GYPSUM BASE FOR VENEER PLASTER SHALL CONFORM TO ASTM C 1396 AND SHALL BE INSTALLED IN ACCORDANCE WITH ASTM C844 BUT NOT LESS THAN THE FOLLOWING REQUIREMENTS. WATER-RESISTANT GYPSUM BACKING BOARD SHALL CONFORM TO ASTM C 1396 AND SHALL BE INSTALLED IN ACCORDANCE WITH ASTM C 840. 2.2.GYPSUM BOARD OR GYPSUM PANEL PRODUCTS SHALL BE INSTALLED PERPENDICULAR TO FRAMING MEMBERS.END JOINTS OF ADJACENT COURSES OF GYPSUM BOARD SHALL NOT OCCUR ON THE SAME JOIST. 2.3.BOARDS SHALL BE CONNECTED TO THE SUPPORTING ELEMENTS (STUDS, JOISTS,RAFTERS, TOP AND BOTTOM PLATES, AND BLOCKING) WITH 6D COOLER (0.092" X 1-7/8" LONG, 1/4" HEAD) OR WALLBOARD NAIL (0.0915" X 1-7/8" LONG, 19/64" HEAD) OR 0.120" NAIL X 1-3/4" LONG, MIN 3/8" HEAD. 2.4.ALTERNATIVELY BOARDS INSTALLED ON THE WALLS MAY BE CONNECTED TO THE SUPPORTING MEMBERS WITH NO.16 GAGE GALV. STAPLE, 1-1/2" LEGS, 1-5/8" LONG. STAPLES SHALL HAVE A MINIMUM CROWN WIDTH OF 7/16", MEASURED OUTSIDE THE LEGS, AND SHALL BE INSTALLED WITH THEIR CROWNS PARALLEL TO THE LONG DIMENSION OF THE FRAMING MEMBERS.STAPLES FOR THE ATTACHMENT OF GYPSUM LATH AND WOVEN-WIRE LATH SHALL HAVE A MINIMUM CROWN WIDTH OF 3/4", MEASURED OUTSIDE THE LEGS. 2.5.TYPE S OR W DRYWALL SCREWS SHALL CONFORM TO REQUIREMENTS OF ASTM C 1002. 2.6.FASTENERS SHALL BE SPACED NOT MORE THAN 7 INCHES ON CENTER AT ALL SUPPORTS, INCLUDING PERIMETER BLOCKING, AND NOT MORE THAN 3/4" FROM THE EDGES AND ENDS OF THE GYPSUM BOARD OR GYPSUM PANEL PRODUCT. 2.7.PERIMETER EDGES OF ALL GYPSUM BOARDS SHALL BE BLOCKED USING A WOOD MEMBER NOT LESS THAN 2"X6" NOMINAL DIMENSION. BLOCKING MATERIAL SHALL BE INSTALLED FLAT OVER THE TOP PLATE OF THE WALL TO PROVIDE A NAILING SURFACE NOT LESS THAN 2" IN WIDTH FOR THE ATTACHMENT OF THE GYPSUM BOARD OR GYPSUM PANEL PRODUCT. 1. EXTERIOR AND INTERIOR CEMENT PLASTER AND LATHING SHALL BE DONE WITH THE APPROPRIATE MATERIALS LISTED IN TABLE BELOW. 2. EXPANDED METAL OR WOVEN WIRE LATH AND PORTLAND CEMENT PLASTER SHALL CONFORM TO THE FOLLOWING: 2.1 EXPANDED METAL OR WOVEN WIRE LATH AND PORTLAND CEMENT SHALL CONFORM TO ASTM C847, ASTM C1032, AND ASTM C150 AND SHALL BE INSTALLED IN ACCORDANCE WITH ASTM C926 AND ASTM C1063. METAL LATH AND LATH ATTACHMENTS SHALL BE OF CORROSION-RESISTANT MATERIAL. 2.2 FASTENER TO STUDS, TOP AND BOTTOM PLATES, AND BLOCKING SHALL BE 0.120" NAIL X 1-1/2" LONG, 7/16" HEAD OR NO.16 GAGE GALV. STAPLE, 7/8" LEGS. STAPLES SHALL HAVE A MINIMUM CROWN WIDTH OF 7/16", MEASURED OUTSIDE THE LEGS, AND SHALL BE INSTALLED WITH THEIR CROWNS PARALLEL TO THE LONG DIMENSION OF THE FRAMING MEMBERS. STAPLES FOR THE ATTACHMENT OF GYPSUM LATH AND WOVEN-WIRE LATH SHALL HAVE A MINIMUM CROWN WIDTH OF 3/4", MEASURED OUTSIDE THE LEGS. 3. MATERIALS SHALL BE STORED IN SUCH A MANNER AS TO PROTECT THEM FROM THE WEATHER. 4. INSTALLATION OF THESE MATERIALS SHALL BE IN COMPLIANCE WITH ASTM C926 AND ASTM C1063. 5. METAL LATH AND LATH ATTACHMENTS SHALL BE OF CORROSION-RESISTANT MATERIAL. 6. BACKING OR A LATH SHALL PROVIDE SUFFICIENT RIGIDITY TO PERMIT PLASTER APPLICATIONS. 6.1 WHERE LATH ON VERTICAL SURFACES EXTENDS BETWEEN RAFTERS OR OTHER SIMILAR PROJECTING MEMBERS, SOLID BACKING SHALL BE INSTALLED TO PROVIDE SUPPORT FOR LATH AND ATTACHMENTS. 6.2 GYPSUM LATH OR GYPSUM WALLBOARD SHALL NOT BE USED AS BACKING FOR CEMENT PLASTER UNO. 7. APPROVED WATER-RESISTIVE BARRIERS SHALL BE INSTALLED AND, WHERE APPLIED OVER WOOD-BASED SHEATHING, SHALL INCLUDE A WATER-RESISTIVE VAPOR-PERMEABLE BARRIER WITH A PERFORMANCE AT LEAST. EQUIVALENT TO TWO LAYERS OF WATER-RESISTIVE BARRIER COMPLYING WITH ASTM E2556, TYPE I. THE INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH THAT EACH LAYER PROVIDES A SEPARATE CONTINUOUS PLANE AND ANY FLASHING (SEE ARCH DWG. AND INSTALLED IN ACCORDANCE WITH SECTION 1404.4 OF CBC) INTENDED TO DRAIN TO THE WATER-RESISTIVE BARRIER IS DIRECTED BETWEEN THE LAYERS. 7.1 EXCEPTION 1: WHERE THE WATER-RESISTIVE BARRIER THAT IS APPLIED OVER WOOD-BASED SHEATHING HAS A WATER RESISTANCE EQUAL TO OR GREATER THAN THAT OF A WATER-RESISTIVE BARRIER COMPLYING WITH ASTM E2556, TYPE II AND IS SEPARATED FROM THE STUCCO BY AN INTERVENING, SUBSTANTIALLY NONWATERY-ABSORBING LAYER OR DRAINAGE SPACE. 7.2 EXCEPTION 2: WHERE THE WATER-RESISTIVE BARRIER IS APPLIED OVER WOOD-BASE SHEATHING IN CLIMATE ZONE 1A, 2A OR 3A, A VENTILATED AIR SPACE SHALL BE PROVIDE BETWEEN THE STUCCO AND WATER-RESISTIVE BARRIER. 8. MASONRY AND CONCRETE SURFACES SHALL BE CLEAN, FREE FROM EFFLORESCENCE, SUFFICIENTLY DAMP AND ROUGH FOR PROPER BOND. IF THE SURFACE IS INSUFFICIENTLY ROUGH, APPROVED BONDING AGENTS OR A PORTLAND CEMENT DASH BOND COAT MIXED IN PROPORTIONS OF NOT MORE THAN TWO PARTS VOLUME OF SAND TO ONE PART VOLUME OF PORTLAND CEMENT OR PLASTIC CEMENT SHALL BE APPLIED. THE DASH BOND COAT SHALL BE LEFT UNDISTURBED AND SHALL BE MOIST CURED NOT LESS THAN 24 HOURS. TABLE 2507 - LATH, PLASTERING MATERIALS AND ACCESSORIES MATERIAL STANDARD ACCESSORIES FOR GYPSUM VENEER BASE ASTM C1047 BLENDED CEMENT ASTM C595 COLD-FORMED STEEL STUDS AND TRACK, STRUCTURAL AISI S240 COLD-FORMED STEEL STUDS AND TRACK, NONSTRUCTURAL AISI S220 EXTERIOR PLASTER BONDING COMPOUNDS ASTM C932 HYDRAULIC CEMENT ASTM C1157; C1600 GYPSUM CASTING AND MOLDING PLASTER ASTM C59 GYPSUM KEENE'S CEMENT ASTM C61 GYPSUM PLASTER ASTM C28 GYPSUM VENEER PLASTER ASTM C587 INTERIOR BONDING COMPOUNDS, GYPSUM ASTM C631 LIME PLASTERS ASTM C5;C206 MASONRY CEMENT ASTM C91 METAL LATH ASTM C847 PLASTER AGGREGATES SAND PERLITE VERMICULITE ASTM C35; C897 ASTM C35 ASTM C35 PLASTIC CEMENT ASTM C1328 PORTLAND CEMENT ASTM C150 STEEL SCREWS ASTM C1002; C954 WELDED WIRE LATH ASTM C933 WOVEN WIRE PLASTER BASE ASTM C103 1. PLASTERING WITH CEMENT PLASTER SHALL BE NOT LESS THAN THREE COATS WHERE APPLIED OVER METAL LATH OR WIRE FABRIC LATH OR GYPSUM BOARD BACKING AS SPECIFIED IN NOTE 5 AND SHALL BE NOT LESS THAN TWO COATS WHERE APPLIED OVER MASONRY OR CONCRETE. IF THE PLASTER SURFACE IS TO BE COMPLETELY COVERED BY VENEER OR OTHER FACING MATERIAL, OR IS COMPLETELY CONCEALED BY ANOTHER WALL, PLASTER APPLICATION NEED ONLY BE TWO COATS, PROVIDED THAT THE TOTAL THICKNESS IS AS SET FORTH IN ASTM C926. 2. ON WOOD FRAME OR STEEL STUD CONSTRUCTION WITH AN ON-GRADE CONCRETE FLOOR SLAB SYSTEM, EXTERIOR PLASTER SHALL BE APPLIED IN SUCH A MANNER AS TO COVER, BUT NOT TO EXTEND BELOW, THE LATH AND PAPER. THE APPLICATION OF LATH, PAPER AND FLASHING OR DRIP SCREEDS SHALL COMPLY WITH ASTM C1063. 3. A MINIMUM 0.019-INCH (NO. 26 GALVANIZED SHEET GAGE), CORROSION-RESISTANT WEEP SCREED WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 3.5 IN. SHALL BE PROVIDED AT OR BELOW THE FOUNDATION PLATE LINE ON EXTERIOR STUD WALLS IN ACCORDANCE WITH ASTM C926. THE WEEP SCREED SHALL BE PLACED NOT LESS THAN 4 IN. ABOVE THE EARTH OR 2 IN. ABOVE PAVED AREAS AND BE OF A TYPE THAT WILL ALLOW TRAPPED WATER TO DRAIN TO THE EXTERIOR OF THE BUILDING. THE WATER-RESISTIVE BARRIER SHALL LAP THE ATTACHMENT FLANGE. THE EXTERIOR LATH SHALL COVER AND TERMINATE ON THE ATTACHMENT FLANGE OF THE WEEP SCREED. 4. ONLY APPROVED PLASTICITY AGENTS AND APPROVED AMOUNTS THEREOF SHALL BE ADDED TO PORTLAND CEMENT OR BLENDED CEMENTS. WHERE PLASTIC CEMENT OR MASONRY CEMENT IS USED, ADDITIONAL LIME OR PLASTICIZERS SHALL NOT BE ADDED. HYDRATED LIME OR THE EQUIVALENT AMOUNT OF LIME PUTTY USED AS A PLASTICIZER IS PERMITTED TO BE ADDED TO CEMENT PLASTER OR CEMENT AND LIME PLASTER IN AN AMOUNT NOT TO EXCEED THAT SET FORTH IN ASTM C926. 5. GYPSUM PLASTER SHALL NOT BE USED ON EXTERIOR SURFACES. 6. CEMENT PLASTER COATS SHALL BE PROTECTED FROM FREEZING FOR A PERIOD OF NOT LESS THAN 24 HOURS AFTER SET HAS OCCURRED. PLASTER SHALL BE APPLIED WHEN THE AMBIENT TEMPERATURE IS HIGHER THAN 40°F, UNLESS PROVISIONS ARE MADE TO KEEP CEMENT PLASTER WORK ABOVE 40°F DURING APPLICATION AND 48 HOURS THEREAFTER. 7. THE SECOND COAT SHALL BE BROUGHT OUT TO PROPER THICKNESS, RODDED AND FLOATED SUFFICIENTLY ROUGH TO PROVIDE ADEQUATE BOND FOR THE FINISH COAT. THE SECOND COAT SHALL NOT HAVE VARIATIONS GREATER THAN 1/4 IN. IN ANY DIRECTION UNDER A 5-FOOT STRAIGHT EDGE. 8. FIRST AND SECOND COATS OF CEMENT PLASTER SHALL BE APPLIED AND MOIST CURED AS SET FORTH IN ASTM C926 AND TABLE BELOW. a.THE FIRST TWO COATS SHALL BE AS REQUIRED FOR THE FIRST COATS OF EXTERIOR PLASTER, EXCEPT THAT THE MOIST-CURING TIME PERIOD BETWEEN THE FIRST AND SECOND COATS SHALL BE NOT LESS THAN 24 HOURS. MOIST CURING SHALL NOT BE REQUIRED WHERE JOB AND WEATHER CONDITIONS ARE FAVORABLE TO THE RETENTION OF MOISTURE IN THE CEMENT PLASTER FOR THE REQUIRED TIME PERIOD. b.TWENTY-FOUR-HOUR MINIMUM INTERVAL BETWEEN COATS O INTERIOR CEMENT PLASTER. OTHER METHODS SHALL BE SUBMITTED FOR REVIEW AND APPROVAL. c.FINISH COAT PLASTER IS PERMITTED TO BE APPLIED TO INTERIOR CEMENT PLASTER BASE COATS AFTER A 48-HOURS PERIOD. 9. WHERE APPLIED DIRECTLY TO UNIT MASONRY SURFACES, THE SECOND COAT IS PERMITTED TO BE APPLIED AS SOON AS THE FIRST COAT HAS ATTAINED SUFFICIENT HARDNESS. 10. THE SECOND COAT IS PERMITTED TO BE APPLIED AS SOON AS THE FIRST COAT HAS ATTAINED SUFFICIENT RIGIDITY TO RECEIVE THE SECOND COAT. 10.1 WHERE USING THIS METHOD OF APPLICATION, CALCIUM ALUMINATE CEMENT UP TO 15 PERCENT OF THE WEIGHT OF THE PORTLAND CEMENT IS PERMITTED TO BE ADDED TO THE MIX. 10.2 CURING OF THE FIRST COAT IS PERMITTED TO BE OMITTED AND THE SECOND COAT SHALL BE CURED AS SET FORTH IN ASTM C926 AND TABLE 2512.6. 11. CEMENT PLASTER FINISH COATS SHALL BE APPLIED OVER BASE COATS THAT HAVE BEEN IN PLACE FOR THE TIME PERIODS SET FORTH IN ASTM C926. THE THIRD OR FINISH COAT SHALL BE APPLIED WITH SUFFICIENT MATERIAL AND PRESSURE TO BOND AND TO COVER THE BROWN COAT AND SHALL BE OF SUFFICIENT THICKNESS TO CONCEAL THE BROWN COAT. TABLE 2512.6 CEMENT PLASTERS COAT MINIMUM PERIOD MOIST CURING MINIMUM INTERVAL BETWEEN COTTS FIRST 48 HOURS 48 HOURS SECOND 48 HOURS 7 DAYS FINISH -NOTE C 1. ALL WALLS,FLOOR,CIELING AND ROOF GYPSUM BOARD SHALL BE AT LEAST 1/2" THICK (UNO ON ARCH. DWG.) AND CONFORM TO THE FOLLOWING REQUIREMENTS: 1.1 GYPSUM WALLBOARD SHALL CONFORM TO ASTM C 1396 AND SHALL BE INSTALLED IN ACCORDANCE WITH ASTM C 840. GYPSUM BASE FOR VENEER PLASTER SHALL CONFORM TO ASTM C 1396 AND SHALL BE INSTALLED IN ACCORDANCE WITH ASTM C844 BUT NOT LESS THAN THE FOLLOWING REQUIREMENTS. WATER-RESISTANT GYPSUM BACKING BOARD SHALL CONFORM TO ASTM C 1396 AND SHALL BE INSTALLED IN ACCORDANCE WITH ASTM C 840. 1.2 GYPSUM BOARD OR GYPSUM PANEL PRODUCTS SHALL BE INSTALLED PERPENDICULAR TO FRAMING MEMBERS. END JOINTS OF ADJACENT COURSES OF GYPSUM BOARD SHALL NOT OCCUR ON THE SAME JOIST. 1.3 BOARDS SHALL BE CONNECTED TO THE SUPPORTING ELEMENTS (STUDS, JOISTS,RAFTERS, TOP AND BOTTOM PLATES, AND BLOCKING) WITH 6D COOLER (0.092" X 1-7/8" LONG, 1/4" HEAD) OR WALLBOARD NAIL (0.0915" X 1-7/8" LONG, 19/64" HEAD) OR 0.120" NAIL X 1-3/4" LONG, MIN 3/8" HEAD. 1.4 ALTERNATIVELY BOARDS INSTALLED ON THE WALLS MAY BE CONNECTED TO THE SUPPORTING MEMBERS WITH NO.16 GAGE GALV. STAPLE, 1-1/2" LEGS, 1-5/8" LONG. STAPLES SHALL HAVE A MINIMUM CROWN WIDTH OF 7/16", MEASURED OUTSIDE THE LEGS, AND SHALL BE INSTALLED WITH THEIR CROWNS PARALLEL TO THE LONG DIMENSION OF THE FRAMING MEMBERS. STAPLES FOR THE ATTACHMENT OF GYPSUM LATH AND WOVEN-WIRE LATH SHALL HAVE A MINIMUM CROWN WIDTH OF 3/4", MEASURED OUTSIDE THE LEGS. 1.5 TYPE S OR W DRYWALL SCREWS SHALL CONFORM TO REQUIREMENTS OF ASTM C 1002. 1.6 FASTENERS SHALL BE SPACED NOT MORE THAN 7 INCHES ON CENTER AT ALL SUPPORTS, INCLUDING PERIMETER BLOCKING, AND NOT MORE THAN 3/4" FROM THE EDGES AND ENDS OF THE GYPSUM BOARD OR GYPSUM PANEL PRODUCT. 1.7 PERIMETER EDGES OF ALL GYPSUM BOARDS SHLL BE BLOCKED USING A WOOD MEMBER NOT LESS THAN 2"X6" NOMINAL DIMENSION. BLOCKING MATERIAL SHALL BE INSTALLED FLAT OVER THE TOP PLATE OF THE WALL TO PROVIDE A NAILING SURFACE NOT LESS THAN 2" IN WIDTH FOR THE ATTACHMENT OF THE GYPSUM BOARD OR GYPSUM PANEL PRODUCT. APPEARANCE GRADE WITH MOISTURE CONTENT BETWEEN 7-14 PERCENT. 5.ALL FABRICATIONS SHALL BE IN ACCORDANCE WITH AITC A190 AND PERFORMED WITH A CERTIFIED FABRICATOR AS PER AITC. 6.GLUED-LAMINATED TIMBERS SHALL HAVE INSPECTION CERTIFICATE AT NO COST TO THE OWNER, OR ENGINEER. A COPY OF THE INSPECTION CERTIFICATE SHALL BE SUBMITTED TO THE BUILDING OFFICIALS, AEOR AND SEOR. 7.UNLESS NOTED OTHERWISE, GLUE LAMINATED TIMERS SHALL NOT HAVE ANY CAMBERS. 8.ENGINEERED STRUCTURAL MEMBERS SHALL NOT BE NOTCHED, DRILLED, OR ALTERED EXCEPT AS PERMITTED BY THE MANUFACTURER'S WRITTEN RECOMMENDATIONS AND AS SPECIFICALLY SHOWN ON THESE DRAWINGS, WHICHEVER IS MORE STRICTER. TABLE FL-2. NAIL PROPERTIES SCHEDULE DESIGNATION LENGTH (IN.)WIRE DIAMETER (IN.)HEAD DIAMETER (IN.) 6d 2 0.113 0.266 8d 2-1/2 0.131 0.281 10d 3 0.148 0.312 12d 3-1/4 0.148 0.312 16d 3-1/2 0.162 0.344 20d 4 0.192 0.406 30d 4-1/2 0.207 0.438 40d 5 0.225 0.469 50d 5-1/2 0.244 0.5 60d 6 0.263 0.531 TABLE FL-3. STRUCTURAL GLUED-LAMINATED TIMBERS AND STRUCTURAL COMPOSITE LUMBER MEMBER Fb (PSI)Fv (PSI)E (x106 PSI) PSL (2.2E)PARALLAM 2900 290 2.2 LVL (2.0E)MICROLLAM LVL 2900 285 2.0 GLB 24F-V4 DF/DF GLB 2400 265 1.8 LSL TIMBERSTRAND 2325 310 1.55 TABLE FL-1. REQUIRED GRADE FOR STRUCTURAL WOOD MEMBERS: ALL STRUCTURAL WOOD MEMBERS SHALL BE DOUGLAS FIR-LARCH CONFORMING TO THE REQUIREMENTS OF WWPA OR WCLIB UNLESSE NOTE OTHERWISE ON THESE DRAWINGS JOIST 2x8 & LARGER NO.2 OR BETTER 3x NO.1 STUD 2x4 NO.2 OR BETTER 2x6 NO.2 OR BETTER PLATE 2x OR 3X NO.2 OR BETTER POST 4x10 & SMALLER NO.2 4x12 & LARGER NO.1 6x & 8x NO.1 BEAM & STRINGERS & HDR 4x10 & SMALLER NO.2 4x12 & LARGER NO.1 6x & 8x NO.1 WALL STUD TO STUD (NOT AT BRACED WALL PANELS)16d COMMON 24” O.C. FACE NAIL STUD TO STUD AND ABUTTING STUDS AT INTERSECTING WALL CORNERS (AT BRACED WALL PANELS)16d COMMON 16” O.C. FACE NAIL BUILT-UP HEADER 16d COMMON 16” O.C. EACH EDGE, FACE NAIL CONTINUOUS HEADER TO STUD 4-8d COMMON TOENAIL TOP PLATE TO TOP PLATE 16d COMMON 16” O.C. FACE NAIL TOP PLATE TO TOP PLATE, AT END JOINTS 8-16d COMMON EACH SIDE OF END JOINT, FACE NAIL (MIN 24” LAP SPLICE LENGTH EACH SIDE OF END JOINT) BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING (NOT AT BRACED WALL PANELS)16d COMMON 16” O.C. FACE NAIL BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING AT BRACED WALL PANELS 2-16d COMMON 16” O.C. FACE NAIL STUD TO TOP OR BOTTOM PLATE 4-8d COMMON TOENAIL TOP OR BOTTOM PLATE TO STUD 2-16d COMMON END NAIL TOP PLATES, LAPS AT CORNERS AND INTERSECTIONS 2-16d COMMON FACE NAIL 1” BRACE TO EACH STUD AND PLATE 2-8d COMMON FACE NAIL 1”X6” SHEATHING TO EACH BEARING 2-8d COMMON FACE NAIL 1”8” AND WIDER SHEATHING TO EACH BEARING 3-8d COMMON FACE NAIL FLOOR JOIST TO SILL, TOP PLATE, OR GIRDER 3-8d COMMON TOENAIL RIM JOIST, BAND JOIST, OR BLOCKING TO TOP PLATE, SILL OR OTHER FRAMING BELOW 8d COMMON 6” O.C., TOENAIL 1”X6” SUBFLOOR OR LESS TO EACH JOIST 2-8d COMMON FACE NAIL 2” SUBFLOOR TO JOIST OR GIRDER 2-16d COMMON FACE NAIL 2” PLANK 2-16d COMMON EACH BEARING, FACE NAIL BUILT UP GIRDERS AND BEAMS, 2” LUMBER LAYERS 20d COMMON 32” O.C. FACE NAIL AT TOP AND BOTTOM STAGGERED ON OPPOSITE SIDES 2-20d COMMON ENDS AND AT EACH SPLICE, FACE NAIL LEDGER STRIP SUPPORTING JOISTS OR RAFTERS 3-16d COMMON EACH JOIST OR RAFTER, FACE NAIL JOIST TO BAND JOIST OR RIM JOIST 3-16d COMMON END NAIL BRIDGING OR BLOCKING TO JOIST, RAFTER OR TRUSS 2-8d COMMON EACH END, TOENAIL 2022 CBC TABLE 2304.10.2 - FASTENING SCHEDULE DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENER SPACING AND LOCATION ROOF BLOCKING BETWEEN CEILING JOISTS, RAFTERS OR TRUSSES TO TOP PLATE OR OTHER FRAMING BELOW 3 - 8d COMMON TOENAIL EACH END BLOCKING BETWEEN RAFTERS OR TRUSS NOT AT THE WALL TOP PLATE, TO RAFTER OR TRUSS 2 - 8d COMMON TOENAIL EACH END 2-16d COMMON END NAIL FLAT BLOCKING TO TRUSS AND WEB FILLER 16d COMMON @6"O.C.FACE NAIL CEILING JOISTS TO TOP PLATE 3-8d COMMON TOENAIL EACH JOIST CEILING JOIST NOT ATTACHED TO PARALLEL RAFTER, LAPS OVER PARTITIONS (NO THRUST) (TABLE AND SECTION2308.7.3.1) 3-16d COMMON FACE NAIL CEILING JOISTS ATTACHED TO PARALLEL RAFTER (HEEL JOINT) (TABLE AND SECTION2308.7.3.1)7-16d COMMON FACE NAIL COLLAR TIE TO RAFTER 3-10d COMMON FACE NAIL RAFTER OR ROOF TRUSS TO TOP PLATE (TABLE AND SECTION 2308.7.5)3-10d COMMON TOENAIL (C) ROOF RAFTERS TO RIDGE VALLEY OR HIP RAFTERS; OR ROOF RAFTER TO 2” RIDGE BEAM 2-16d COMMON END NAIL 3-10d COMMON TOENAIL DATE: P.M.: DRAWN BY: JOB NO.: 30211 Avenida de las Banderas, Suite 200, Rancho Santa Margarita, California, 92688 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D E SI GN B U I L D CNI UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT REV DATE REMARKS M.A. ISSUED FOR PERMIT12.17.20240 07.13.2025 20241149 ISSUED PER CITY PERMIT07.13.20251 S0.02 CONSTRUCTION NOTES 07/15/2025 EXP. 06-30-2026 9 SCALE:NTS. F F NOTE: ADJUST FOUNDATION ELEVATIONS SHOWN ON DWGS. IF NECESSARY TO MAINTAIN THE MAX. OF 7 IN 10 SLOPE BTWN. FOUNDATIONS AND ADJACENT EXCAVATIONS FOR DRAINS OR OTHER ITEMS LINE OF EXCAVATION MAINTAIN STABLE SLOPE RELATION OF ADJACENT FOUNDATIONS AND EXCAVATIONS F11 SCALE:NTS. 12" MIN.12" MIN. 7 10 7 10 SCALE:NTS.SCALE:NTS. 1" CLEAR SLEEVE AROUND PIPE CAULK PIPE TRENCH PIPE NOTES: 1. DEPTH OF FOUNDATIONS MAY BE DETERMINED BY LOCATION OF PIPE. 2. GENERAL CONTRACTOR SHALL CONSULT WITH MECHANICAL CONTRACTOR TO DETERMINE DEPTH AND LOCATION OF PIPES. 3. NO PIPE INSIDE THE THICKENED PART OF FOUNDATION. 4. WHERE PIPES CROSS UNDER THE FOUNDATION AND ARE NOT MORE THAN 3' BELOW THE FOUNDATION, EXCAVATION SHALL BE EXTENDED TO PIPE AND FILLED WITH MASS CONC. 1" CLEAR SLEEVE AROUND PIPE CAULK F SCALE:NTS. PIPE THRU FOUNDATION 18" MIN. 6" NO EXCAVATION BELOW LINES NO EXCAVATION BELOW LINES 6" MI N . 6" MI N . B WALL FOUNDATION 2" OF APPROVED HIGHLY COMPRESSIBLE MATERIAL AROUND PIPE RUNS PROVIDE 2500 PSI CONC. BACKFILL WHERE EXCAVATION RUNS ACROSS AND UNDER THE LINE OF FOUNDATION WHEN "B" EXCEEDS 6'-0" FOOTING SHALL BE STEPPED DN. FROM BOTH SIDES PIPES CROSSING BENEATH CONT. WALL FOUNDATION SCALE:NTS. F t ³t 4 13 F F SCALE:NTS. 1 3" C L R . UNDISTURBED NATURAL SOILS OR ENGINEERED FILL E.N. 5/8" DIA. @ 48" W/ 7" MIN. EMBED., UNO IN SHEAR WALL SCHEDULE STUD WALL PER PLAN UNO PER SHEAR WALL SCHED. ELASTOMETRIC JOINT SEALANT (WHERE REQD.) ALL TOP & BOT BARS IN FOUNDATION SHALL HAVE STANDARD HOOKS AT THE ENDS. SOG PER PLAN 3" CLR. VAPOR RETARDER SEE ARCH./CIVIL DWG. H SEE NOTE 2 EXT. WALL SHEATHING 2x UC4A OR HIGHER SILL PLATE 3x UC4A AT SHEAR WALLS P.T. SEE ARCH./CIVIL DWGS. STD. HOOK NOTE: 1- PROVIDE THICK. FILL BLANKET UNDER HARD SCAPE AREAS. AS PER ARCH./CIVIL DWG. FOR MORE INFORMATION IF APPLICABLE. 2- MIN. 8" FROM SOIL AT UNPAVED AREA OR 2" FROM T.O. THE PAVED MATERIAL. t EXT. STRIP FOUNDATION PER PLAN 3" C L R . 2x UC4A OR HIGHER SILL PLATE 3x UC4A AT SHEAR WALLS P.T. E.N. WALL SHEATHING PER PLAN STUD WALL PER PLAN UNO PER SHEAR WALL SCHED. SOG PER PLAN #4@16" O.C. DOWELS ALT. UNDISTURBED NATURAL SOILS OR ENGINEERED FILL t SCALE:NTS. 5 3" CLR. (2)#5 TOP & BOT INT. STRIP FOUNDATION (2)#5 TOP & BOT DOWELS TO MATCH SOG REINF.24 " SCALE:NTS. 2 EXT. STRIP FOUNDATION W/ ANCHOR SCALE:NTS. 6 INT. STRIP FOUNDATION W/ ANCHOR (SB/SSTB) PER PLAN 5/8" DIA. @ 48" W/ 7" MIN. EMBED., UNO IN SHEAR WALL SCHEDULE SB SHOWN (SSTB SIMILAR) VAPOR RETARDER SEE ARCH./CIVIL DWG. ALL TOP & BOT BARS IN FOUNDATION SHALL HAVE STANDARD HOOKS AT THE ENDS. STD. HOOK 13 4" 11 2"12" MIN. 11 1 2" M A X . Le SB SHOWN (SSTB SIMILAR) 4" MIN. 12 " M I N . PLAN VIEW Le ADD EXTRA #4 BARS EA. SIDE OF HOLD DOWN 1.5 Le NOTE: FOUNDATION DETAILS AND REINFORCEMENT ARE NOT SHOWN FOR CLARITY. SEE FOUNDATION DETAILS FOR THE BALANCE OF INFORMATION AND DETAILS THAT ARE NOT SHOWN SCALE:NTS.SCALE:NTS. 3 SCALE:NTS. 10CONTRACTION JOINT INT. NON-LOAD BEARING WALLS (PARTITIONS) ON SOG7 IMPERVIOUS MOISTURE BARRIER BTWN. THE SILL PLATE AND SOG HOT-DIP GALV. OR STAINLESS STEEL ANCHOR AND WASHER (SEE NOTE 2) 2x STUDS @16" O.C. NON-LOAD BEARING INT. PARTION, NON-SHEAR WALL 2x UC4A OR HIGHER SILL PLATE P.T. SOG PER PLAN A SECTION A 7db<L<12"ANCHOR SOG PER PLANS END OF SILL PLATE WHERE OCCUR NOTE: 1. UNO ON THE PLANS OR SHEAR WALL TABLE, WOOD SILL PLATES AND WOOD PARTITION WALLS SUPPORTED DIRECTLY ON CONC. SLAB SHALL BE CONSTRUCTED AS FOLLOWS: a. ANCHOR BOLTS SHALL BE LOCATED IN THE MIDDLE THIRD OF THE WIDTH OF THE PLATE. b. A NUT AND WASHER SHALL BE TIGHTENED ON EACH ANCHOR BOLT. c.THERE SHALL BE NOT FEWER THAN TWO BOLTS PER PLATE SECTION W/ ONE BOLT LOCATED NOT MORE THAN 12 IN AND LES THAN SEVEN BOLT DIAMETERS FROM EACH END OF THE PLATE SECTION. d. SILL PLATES SHALL BE PRESSURE TREATED AND PROTECTED AGAINST DECAY AND TERMITES (UC4A OR BETTER). 2. ANCHORS SHALL CONFIRM TO: a. RAMSET 1524 SDP POWER-ACTUATED FASTENER (ZINC-CHROMATE) WITH ZINC-COATED WASHERS AND 1.375" EMBEDMENT DEPTH AT 24" OC (ICC ESR 2690) b. 3/8" Ø STAINLESS-STEEL TITEN HD WASHER HEAD W/ 2.75" EMBEDMENT DEPTH AND BD 1/2-3HDG WASHER BEARING PLATE AT 24" OC (ICC ESR 2713), c. 2.5" x 12/64" (0.177) Ø W/ 3/8" Ø HEAD POWDER DRIVEN FASTENER SHOT 14 GA x 17/16" Ø WASHER AT 24" OC, HILTI DS62P10 ICC-ES ESR-1663 OR EQUAL NOTE: 1. SEE ARCHITECTURAL DRAWING FOR EXTENT OF SOG 2. IF ANY DISCREPANCIES EXIST BTWN. STRUCTURAL DWGS. AND ARCH. DWGS. ARCH. DWGS. GOVERNED EDGED PATIO SLAB ADD EXTRA #4 BARS EA. SIDE OF HOLD DOWN SLAB NOT SHOWN FOR CLARITY PER PLAN 12" MIN. FOR SSTB/SB PER PLAN 12" MIN. PLAN VIEW NOTE: FOUNDATION DETAILS AND REINFORCEMENT ARE NOT SHOWN FOR CLARITY. SEE FOUNDATION DETAILS FOR THE BALANCE OF INFORMATION AND DETAILS THAT ARE NOT SHOWN SLAB NOT SHOWN FOR CLARITY 112" 12" MIN.11 2" 134" 1. 5 L e F FFF FF 24 " M I N . 6" (FOR HDU14) 6" (F O R HD U 1 4 ) SIMPSON SB SIMPSON SSTB SIMPSON SB SIMPSON SSTB NOTE: THE DIAMOND-SHAPED JOINTS (6) MAY BE OMITTED IF COLUMN FOOTINGS ARE BELOW FLOOR LEVEL AND THE COLUMN IS WRAPPED WITH TWO LAYERS OF SHEATHING MEMBRANE OR JOINT FILLER TO BREAK THE BOND. 1. CONTROL JOINTS WITHIN 3050MM (120 IN). OF CORNERS 2. SPACING OF JOINTS 6100MM (240 IN). MAX. CONTROL JOINTS IN FLOOR SLAB 3. FLOOR SLAB JOINT IN FLOOR SLAB 4. CONTROL JOINTS AROUND COLUMN FOOTINGS (SEE NOTE) 5. FLOOR SLAB JOINT SPACING OF 6 M (20 FT.) MAXIMUM 6. CONTROL JOINT AROUND COLUMN FOOTINGS (SEE NOTE) 2 1 1 5 3 3 4 6 3 5 LOCATION OF CONTROL JOINTS F SCALE:NTS. 12 24" 24 " 24" 24 " EXTRA #4 BARS SB/SSTB 4" HOLD DOWN ANCHOR SCHEDULE AT FOUNDATION F SCALE:NTS. 8 HDU2 1/4x2.5 6 4"x4"2,960 LB SSTB 16 5/8"17 20" HDU4 1/4x2.5 10 4"x4"4,500 LB SSTB 20 5/8"18 22" HDU5 1/4x2.5 14 4"x4"5,600 LB SSTB 24 5/8"18 22" HDU8 1/4x2.5 20 4"x4"6,970 LB SSTB 28 7/8"25 28" HDU11 1/4x2.5 30 4"x8"9,535 LB SB1x30 1"24 28" HDU14***1/4x2.5 36 4"x8"13,090 LB SB1x30**-18*1"24, F**=17 28" HD19 1" BOLT 5 6"x6" NO.1 19,070 LB PAB10 1 1/4"14.5,F=22 24" HOLD DOWN TYP. SDS SCREW SIZE (IN.) NO. OF SCREWS MIN. WOOD POST SIZE DESIGN CAPACITY ANCHOR TYPE DIA.Le, F(IN.)MIN. FON. DEPTH LSTHD8 0.148x3.25 16 4"x4"1,600 LB 8 12" STHD10 0.148x3.25 20 4"x4"2,100 LB 10 14" STHD14 0.148x3.25 24 4"x4"3,500 LB 14 18" HDU2 1/4x2.5 6 4"x4"3,000 LB SSTB 16 5/8"13 16" HDU4 1/4x2.5 10 4"x4"4,500 LB SSTB 20 5/8"17 22" HDU5 1/4x2.5 14 4"x4"5,600 LB SSTB 24 5/8"21 26" HDU8 1/4x2.5 20 4"x4"6,900 LB SSTB 28 7/8"25 28" HDU11 1/4x2.5 30 4"x8"11,100 LB SB1x30 1"24 28" HDU14***1/4x2.5 36 4"x8"13,000 LB SB1x30**-18*1"24, F**=17 28" HD19 1" BOLT 5 6"x6" NO.1 19,070 LB PAB10 1 1/4"14.5,F=22 24" NOTE: *WHERE NOTED, SB1x30 REQUIRES FOUNDATION WIDTH TO BE 18" WIDE. **PAB8 SOLUTION MAY ALSO BE USED. FOR PAB8 COVERAGE ON EACH SIDE OF THE BOLT SHALL BE MINIMUM F". ***WOOD MEMBER SHALL BE 8"x4" OR LARGER 1. ANCHORS DESIGNATED AS ASTM A193 GRADE B7 THREADED RODS TO USE ASTM A563 GRADE DH HEAVY HEX NUTS AND ASTM F436 WASHERS. ANCHOR RODS SHALL CONFORM TO ASTM A36 THREADED RODS W/ ASTM A563 GRADE A NUTS AND ANSI B18.22.1 TYPE A WASHERS, UNLESS OTHERWISE NOTED. 2. ALL NUTS SHALL BE HOT DIP OR MECHANICAL ZINC COATED, GRADE A FINISH, HEAVY HEX AND CONFORM TO ASTM A563 W/ F436 WASHERS, UNO. MIDWALL/CORNER GARAGE CURB SOG PER PLAN 3" C L R . 1 1 12 " M I N . UNDISTURBED NATURAL SOILS OR ENGINEERED FILL t 3" CLR. 2#4 12" A B SECTION A SECTION B SCALE:NTS.SCALE:NTS. MI N . ( t 4,1 1 4") PROVIDE 1/4" SAWCUT OR 1/8" WIDE TOOLED JOINT WITHIN 24 HOUR OF POUR, FILL W/ SEALANT AS REQD. AS PER ARCH. DWG. SEE JOINT FILLER DETAILS SOG PER PLAN t/ 2 t SEE SOG. NOTES FOR SUBGRADE DETAILS SECTION OF LANDING /EQUIPMENT SLAB #4@18"O.C. 3" C L R . 1 1 6" 3" CLR.#4 6" 3" C L R . 3" CLR.#4 SEE ARCH. DWG. PER CIVIL/CITY GUIDE LINE AS P E R A R C H . D W G . 5" DATE: P.M.: DRAWN BY: JOB NO.: 30211 Avenida de las Banderas, Suite 200, Rancho Santa Margarita, California, 92688 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D E SI GN B U I L D CNI UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT REV DATE REMARKS M.A. ISSUED FOR PERMIT12.17.20240 07.13.2025 20241149 ISSUED PER CITY PERMIT07.13.20251 S1.01 TYPICAL FOUNDATION DETAILS 07/15/2025 EXP. 06-30-2026 JACK RAFTERS TO HIP RAFTER CONNE. SCALE:NTS. 8 W HIP RAFTER JACK RAFTER SIMPSON CS14 JACK RAFTER HANGER W SCALE:NTS. 75 BEAM SPLICE SCALE:NTS. W SIMPSON CCQ W SCALE:NTS. DISCONTINUOUS TOP PLATE w/(1) CMSTC16 36" EA. SIDE BEAM PER PLAN POST PER PLAN CCQ POST CAP CENTER OF SPLICE "MSTC40" STRAP SHEATHING PER PLAN RAFTERS PER PLAN SIMPSON MSTA24 @EA. RAFTER LRUZ SIMPSON SLOPED HANGER PER SCHEDULE RIDGE BEAM TO RAFTER CONNE. RIDGE BEAM PER PLAN SIMPSON LRUZSIMPSON MSTA ROOF SHEATHING PER PLAN FILLERB.N. SHEAR TRANSFER AT ROOF SIMPSON H2.5ASIMPSON A35 CEILING JOIST PER PLAN WHERE OCCUR A35 EACH BLOCK U.N.O. PER SHEAR WALL SCHEDULE H2.5A INSTALLED AT 48" O.C. (OR AT PLYWOOD EDGE JOINTS) MI N . 6 " E.N. B.N. ROOF SHT'G PER PLAN ROOF RAFTER PER PLAN (7)16d MIN. COMMON NAILS EA. END. SHEAR WALL PER PLAN PLY WOOD MAY OTHER SIDE DBL. 2xTOP PLATE 2xRIM 2xBLK'G STUD WALL PER PLAN UNO PER SHEAR WALL SCHED. TYPICAL SHEARWALL SCHEDULE1 W SCALE:NTS. 6 NOTE 1.PANELS SHALL NOT BE LESS THAN 4'X8', EXCEPT AT BOUNDARIES AND CHANGE IN FRAMING. ALL EDGE OF PANELS SHALL BE SUPPORTED BY AND FASTENED TO FRAMING MEMBERS OR BLOCKING. 2.ALL SHEAR WALL ARE BLOCKED SHEAR WALLS AND ALL JOINTS IN SHEATHING SHALL OCCUR OVER AND BE FASTENED TO COMMON FRAMING MEMBERS OR COMMON BLOCKING. 3.SHEATHING SHALL NOT BE USED TO SPLICE BOUNDARY ELEMENTS. ALL POSTS, STUDS AND COLUMNS SHALL BE FRAMED TO PROVIDE FULL END BEARING. 4.CONTRACTOR SHALL REVIEW ALL TYPICAL SHEAR WALL CONNECTION DETAILS PRIOR TO START CONSTRUCTION. 5.STRUCTURAL PLYWOOD PANELS SHALL BE INSTALLED PRIOR TO ALL THE INSTALLATION OF ANY FRAMING THAT MAY INTERRUPT THE CONTINUITY OF THE PLYWOOD. 6.SHEAR WALL SHEATHING SHALL BE 15/32" CD, CC OR BETTER PLYWOOD. W/ ALL EDGES BLOCKED AND NAILED PER THE SHEAR WAIL SCHEDULE. 7.TYPICAL FASTENERS: 10d COMMON U.N.O. NAILS EXPOSED TO THE EXTERIOR SHALL BE GALVANIZED. 8.FRAMING: 2X D.F. TYP. @16" O.C.(MAX.) 9.FRAMING & BLOCKING AT ADJOINING PANEL EDGES SHALL BE 3” NOMINAL OR WIDER AND NAILS SHALL BE STAGGERED IN TWO ROWS ALONG PANEL EDGES WHERE SPACING IS 3” OR LESS ON CENTER. SHEAR WALL FRAMING AND STUDS SHALL BE CONTENTIOUS BETWEEN THE BOTTOM PLATE AND TOP PLATE. 10.END NAIL STUDS TO SILL PLATE WITH (2) 20d BOX NAIL INSTEAD OF (2) 16d COMMON NAILS. 11.IF NEW ANCHOR BOLTS "REQUIRED AT EXISTING FOUNDATION. PROVIDE 5/8” X MIN. 12” EMBEDMENT INTO EXISTING CONCRETE EPOXIED ANCHOR BOLTS SPACING SHOWN AT SHEAR WALL SCHEDULE. PROVIDE 3”X3”X1/4” PLATE WASHER. 12.CONTRACTOR TO VERIFY THE EXISTING PLYWOOD EDGE NAILING. TYPE OF PLYWOOD USED AND SPACING ON EXISTING ANCHOR BOLTS IN FILED, TYPICAL. 13.SPECIAL INSPECTION BY INSPECTOR REQUIRED FOR HOLD-DOWN INSTALLATION INTO EXISTING FOUNDATION. 14.SPECIAL INSPECTION IS REQUIRED FOR STRUCTURAL WOOD SHEAR WALL COMPONENTS WITH NAIL SPACING CLOSER THAN 4” OC PER CBC 1705.11.2. 15.ALL NAILS SHALL BE COMMON NAILS. PROVIDE HOT DIPPED GALVANIZED NAILS AT ALL FIRE TREATED OR PRESSURE TREATED PLYWOOD AND STUDS. 16.WHERE PLYWOOD IS APPLIED ON BOTH FACES OF A WALL AND NAIL SPACING IS LESS THAN 6" O.C. ON EITHER SIDE, PANEL JOINTS SHALL BE OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS OR FRAMING SHALL BE 3" NOMINAL OR THICKER AND NAILS ON EACH SIDE BE STAGGERED. 3x FRAMING SHALL BE USED AT BOTTOM SILL PLATE AND ALL BLOCKING. ELEVATION WALL LENGTH AS SPECIFIED ON PLANS UPPER FLOOR LEVEL NOTE: ALTERNATE 1/2" GAP PLYWD. JOINT AT EXT. CONDITION, LOCATED AT JST. MID-HEIGHT TRIMMERS PER TYPICAL STUD WALL FRAMING AT OPENING DETAIL TYPICAL PROVIDE EDGE NAILING (E.N.) AT ALL PANEL EDGES TYPICAL PROVIDE FIELD NAILING (F.N.) AT ALL OTHER SUPPORTS BOUNDARY POST, SEE PLANS AND ANCHOR TABLE T.O. CONC. 1/4" GAP (PLYWD. TO T.O. CONC.) 3x (MIN.) SILL PLATE (P.T.D.F.) STUD WALL PER PLAN UNO. PER SHEAR WALL SCHED. SHT'G SEE SCHEDULE 3x STUD AT ALL ADJOINING PANEL EDGES 3x BLK'G AT ALL ADJOINING PANEL EDGES DOUBLE T.PLATES ALTERNATE STAGGERED NAILING JST. OR BLK'G (SEE PLAN FOR JST. DIRECTION) FOR SDS SCREWS, USE MIN. 2x BLK'G OR RIM JST. SILL PLATE NAILINGS OR SIMPSON SDS SCREWS TO JST. OR BLK'G SEE SCHEDULE (2) 2x OR 3x SILL PLATE OPENING WHERE OCCURS 8x D A MI N . 12 " M I N . ANCHOR ROD 1" MIN. THREAD **15/32" STRUCTURAL I OSB CAN BE USED INSTEAD OF 15/32" PLYWOOD BP/BPS 5 8" (3"x3"x1 4") ***SIMPSON THDB62100H SHALL BE USE FOR ANCHORING INTO THE EXISTING FOUNDATION, UNO ON PLANS SWXB NO PENETERATION OR CUTTING IS ALLOW IN THE SHEAR WALL PANELS AND STUDS JST. OR BLK'G ANCHORS TO DOUBLE T.PLATES, SEE SCHEDULE AT 4" WALLS: PROVIDE 1/4"X3"X3" STEEL WASHER UNDER EACH NUT. AT 6" WALLS: PROVIDE 1/4"X5"X5" STEEL WASHER UNDER EACH NUT. ALL STEEL PARTS SHALL BE HOT DIPPED GALVANIZED SHEAR WALL SCHEDULE SEE NOTE 10 SIMPSON SDS25600 @ 14" O.C. ALT 16d @ 4" O.C. 15/32" APA RATED 4-PLY OR 5-PLY STRUCT-I PLYWD. (PI 32/16) 10d @6:12 10d @4:12 10d @2:12 10d @4:12 10d @3:12 10d @2:12 UPPER FLOOR SILL PLATE NAILING ANCHOR ROD SPACING WALL CAPACITY (REDUCE 10% FOR FIRE TREATED WOOD SEE NOTES) NAILINGMATERIALTYP. SW3B SW4B SW2B SW4 SW2 SW1 SW1A (EDGE:FIELD) W/ MIN. 1 1/2'' PENETRATION W/ MIN. 1 1/2'' PENETRATION W/ MIN. 1 1/2'' PENETRATION W/ MIN. 1 1/2'' PENETRATION W/ MIN. 1 1/2'' PENETRATION W/ MIN. 1 1/2'' PENETRATION SIMPSON SDS25600 @ 4'' O.C. 15/32" APA RATED 4-PLY OR 5-PLY STRUCT-I PLYWD. (PI 32/16) 15/32" APA RATED 4-PLY OR 5-PLY STRUCT-I PLYWD. (PI 32/16) 15/32" APA RATED 4-PLY OR 5-PLY STRUCT-I PLYWD. (PI 32/16) BOTH SIDES 15/32" APA RATED 4-PLY OR 5-PLY STRUCT-I PLYWD. (PI 32/16) BOTH SIDES 15/32" APA RATED 4-PLY OR 5-PLY STRUCT-I PLYWD. (PI 32/16) BOTH SIDES SIMPSON SDS25600 @ 14" O.C. ALT 16d @ 4" O.C. SIMPSON SDS25600 @ 9" O.C. ALT 16d @ 3 1/2" O.C. SIMPSON SDS25600 @ 4'' O.C. SIMPSON SDS25600 @ 3'' O.C. SIMPSON SDS25600 @ 2'' O.C. STAGGERED 310 PLF (ASD) 2x BLK. & STUD AT ALL EDGES 465 PLF (ASD) 3x BLK. & STUD W/ STGG. NAIL AT ALL EDGES 800 PLF (ASD) 3x BLK. & STUD W/ STGG. NAIL AT ALL EDGES 935 PLF (ASD) 3x BLK. & STUD W/ STGG. NAIL AT ALL EDGES 1220 PLF (ASD) 3x BLK. & STUD W/ STGG. NAIL AT ALL EDGES 1600 PLF (ASD) 3x BLK. & STUD W/ STGG. NAIL AT ALL EDGES 10d @3:12 SW3 W/ MIN. 1 1/2'' PENETRATION SIMPSON SDS25600 @ 6'' O.C. 15/32" APA RATED 4-PLY OR 5-PLY STRUCT-I PLYWD. (PI 32/16) 610 PLF (ASD) 3x BLK. & STUD W/ STGG. NAIL AT ALL EDGES SIMPSON A35 @16" O.C. ALT. SIMPSON LTP4 @16" O.C. SIMPSON A35 @10" O.C. ALT. SIMPSON LTP4 @10" O.C. SIMPSON A35 @8" O.C. ALT. SIMPSON LTP4 @8" O.C. SIMPSON A35 @6" O.C. ALT. SIMPSON LTP4 @6" O.C. SIMPSON A35 @5" O.C. ALT. SIMPSON LTP4 @5" O.C. SIMPSON A35 @8" O.C. EA. SIDE ALT. SIMPSON LTP4 @8" O.C. EA. SIDE SIMPSON A35 @6" O.C. EA. SIDE ALT. SIMPSON LTP4 @6" O.C. EA. SIDE SIMPSON A35 @22" O.C. ALT. SIMPSON LTP4 @22" O.C. 5/8"ø @32" O.C. W/7" EMBEDMENT (2 MIN.) 5/8"ø @32" O.C. W/7" EMBEDMENT (2 MIN.) 5/8"ø @24" O.C. W/7" EMBEDMENT (2 MIN.) 5/8"ø @18" O.C. W/7" EMBEDMENT (3 MIN.) 5/8"ø @16" O.C. W/7" EMBEDMENT (3 MIN.) 5/8"ø @12" O.C. W/7" EMBEDMENT (3 MIN.) 5/8"ø @9" O.C. W/7" EMBEDMENT (3 MIN.) 5/8"ø @48" O.C. W/7" EMBEDMENT (2 MIN.) SILL/BOT PLATE 2x 3x 3x 3x 2x 3x 3x 3x SHEAR TRANSFER AT DOUBLE TOP PLATE 10d @6:12 285 PLF (ASD) 2x BLK. & STUD AT ALL EDGESW/ MIN. 1 1/2'' PENETRATION 15/32" APA RATED 4-PLY OR 5-PLY STRUCT-I PLYWD. (PI 32/16) NOTE: PRESSURE TREAT ALL SILLS BRG. ON CONC. OR MAS. BLOCK. 878" M A X . 6" M I N . SILL PLATE 91 8" MAX. 6" MIN. 5" MAX. PROVIDE 1 1/2"x1/8" STRAP W/(4)16d EA. SIDE OF NOTCH OR HOLE WHERE NOTCH OR HOLE IS MORE THAN 1/3 WIDTH OF SILL PLATE 5/8" ANCHOR ROD @4'-0" O.C. MAX. W/STD. WASHER 7" MIN. EMBED. UNO IN SHEAR WALL SCHEDULE 2x BLK'G W/(2)16d (2)16d END NAILS 2x PLATE W/ (4)16d FOUNDATION REINFORCING NOT SHOWN FOR CLARITY 2x STUDS PER PLAN PLAN W SCALE:NTS. J BOLT AND NOUTCH IN SILL PLATE 91 8" MAX. 6" MIN. 91 8" MAX. 6" MIN. 5" MAX. PROVIDE HOT DIPPED GALV. ANCHOR ROD AND PLATE WASHERS PER PROJECT SPECS. ANCHOR ROD 1" MIN. THREAD 12 " M I N . BP 5/8" (2 1/2"x2 1/2"x1/4") 2 WSP SIMPSON SDS25600 @ 14" O.C. ALT 16d @ 4" O.C. SIMPSON A35 @16" O.C. ALT. SIMPSON LTP4 @16" O.C. 5/8"ø @48" O.C. W/7" EMBEDMENT (2 MIN.) CRC BRACED WALL SCHEDULE UPPER FLOOR SILL PLATE NAILING ANCHOR ROD SPACING WALL CAPACITY (REDUCE 10% FOR FIRE TREATED WOOD SEE NOTES) NAILINGMATERIALTYP.(EDGE:FIELD) SILL/BOT PLATE 2x 2x SHEAR TRANSFER AT DOUBLE TOP PLATE 1/2" GYPSUM BOARD AS PER ARCH. DWG. ON BOTH FACE 1-1/2"x 0.120" GALVANIZED ROOFING NAIL 7/16" HEAD DIA. OR 1-1/4" LONG 16 GA. @6:6 ON ALL FRAMING MEMBERS GB SIMPSON A35 @16" O.C. ALT. SIMPSON LTP4 @16" O.C. 5/8"ø @48" O.C. W/7" EMBEDMENT (2 MIN.) PORTLAND CEMENT PLASTER PLUS GYPSUM BOARD ON THE OTHER FACE 1-1/2" LONG, 11 GAGE, 0.12" DIA., 7 16" DIA., HEAD NAILS @6:6 ON ALL FRAMING MEMBERS PCP SIMPSON SDS25600 @ 14" O.C. ALT 16d @ 4" O.C. SIMPSON A35 @16" O.C. ALT. SIMPSON LTP4 @16" O.C. CRC TABLE BLOCK HORIZONTAL BWP JOINTS 5/8"ø @48" O.C. W/7" EMBEDMENT (2 MIN.) SIMPSON SDS25600 @ 14" O.C. ALT 16d @ 4" O.C. CRC TABLE BLOCK HORIZONTAL BWP JOINTS 2x3/8" APA RATED STRUCT-I PLYWD. 8d @6:6 W/ MIN. 1 1/2'' PENETRATION TYPICAL CRC BRACED WALL SCHEDULE4 W SCALE:NTS. NOTE: FOR MORE INFORMATION AND NOTES SEE DETAIL 1/S1.21. W SCALE:NTS. ALTERNATE T&B PLATE SHEAR WALL E.N. DETAIL NOTES: 1. * AT CONTRACTOR'S OPTION: E.N. CAN BE STAGGERED TO EA. MEMBER OF DOUBLE T&B PLATE. ADD 16d@6" O.C. FOR ALL WALLS W/ SINGLE SIDED SHT'G AND 16d@3" O.C. STAGGERED FOR ALL WALLS W/ DOUBLE SIDED SHT'G. ADDITIONAL 16d NAILS OCCUR AT T.PLATE ONLY. 2. FOR REMAINDER OF INFORMATION NOT SHOWN SEE SHEAR WALL SCHEDULE AND DETAILS. SHEAR WALL SHEATHING WHERE OCCURS SHEAR WALL SHEATHING E.N. * STAGGERED E.N. FRAMING WHERE OCCURS * STAGGERED E.N. E.N. * STAGGERED E.N. E.N.FLOOR OR ROOF JOIST PER PLAN * ADDED 16d NAILING (2)2x BLK'G SHEATHING PER PLAN 3 CRC TABLE BLOCK HORIZONTAL BWP JOINTS 5/8" GYPSUM BOARD AS PER ARCH. DWG. ON BOTH FACE 1-3/4"x 0.120" GALVANIZED ROOFING NAIL 7/16" HEAD DIA. OR 1-1/4" LONG 16 GA. @6:6 ON ALL FRAMING MEMBERS 17. NAILS SHALL BE PLACED AT LEAST 3/8" FROM PANEL EDGES AND ENDS AT LEAST 1/2" FROM THE EDGE OF THE CONNECTING MEMBERS. 18.SIMPSON 'LTP4' FRAMING ANCHOR MAY BE APPLIED OVER 1/2" SHEATHING WITH 8d COMMON NAILS 0.131x2 /12" NAIL. 19. INDICATES SHEATHING OCCURS ON BOTH SIDES OF WALL AS SHOWN ON PLAN. 20.SHEATHING NAILS OR OTHER APPROVED SHEATHING CONNECTORS SHALL BE DRIVEN SUCH THAT THEIR HEAD OR CROWN IS FLUSH WITH THE SURFACE OF THE SHEATHING. OVER-DRIVEN NAILS WILL BE DEEMED UNSATISFACTORY. 21.PROVIDE A SINGLE 3X NOMINAL OR WIDER FRAMING MEMBER AT BOTTOM SILL PLATE AND BEHIND VERTICAL AND HORIZONTAL EDGES, MINIMUM 1/2" EDGE NAILING DISTANCE AT PANEL ENDS AND EDGES, AND STRUCTURAL OBSERVATION PER GENERAL NOTES. 22.MINIMUM EDGE DISTANCE FOR ANCHOR BOLTS SHALL BE 1-3/4" . ALL ANCHOR BOLTS SHALL INCLUDE A MINIMUM 0.229”X3”X3” STEEL PLATE WASHER. THE HOLE IN THE PLATE WASHER SHALL BE PERMITTED TO BE DIAGONALLY SLOTTED WITH A WIDTH OF UP TO 3/16” LARGER THAN THE BOLT DIAMETER AND A SLOT LENGTH NOT TO EXCEED 1-3/4" PROVIDED A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND THE NUT. THE PLATE WASHER SHALL EXTEND TO WITHIN 1/2" OF THE EDGE OF THE BOTTOM PLATE ON THE SIDE(S) FOR SHEATHING WITH SHEAR DESIGN VALUES EXCEEDING 400 PLF. 23.WHEN FASTENERS CONNECTING THE TWO FRAMING MEMBERS ARE SPACED LESS THAN 4" IN CENTER, THEY SHALL BE STAGGERED. 24.WHERE ANY OF THE FOLLOWING CONDITIONS OCCUR, THE WIDTH OF THE NAILED FACE OF A COMMON FRAMING MEMBER OR BLOCKING AT ADJOINING PANEL EDGES SHALL BE 3" NOMINAL OR GREATER AND NAILING SHALL BE STAGGERED AT ALL PANEL EDGES: 24.1. NAIL SPACING OF 2" ON CENTER AT ADJOINING PANEL EDGES IS SPECIFIED, OR 24.2. 10D COMMON NAILS HAVING PENETRATION INTO FRAMING MEMBERS AND BLOCKING OF MORE THAN 1-1/2" ARE SPECIFIED AT 3" ON CENTER,OR LESS AT ADJOINING PANEL EDGES, OR 24.3.THE NOMINAL UNIT SHEAR CAPACITY OF THE SHEAR WALL EXCEEDS 350 PLF.PROVIDE 3X SILL/BOT PLATE AND FRAMING MEMBERS FOR SHEAR WALLS WHERE ALLOWABLE SHEAR VALUE EXCEEDS 350 PLF. 25. ALL STEEL CONNECTORS INCLUDING BOLTS, SCR EWS AND N AILS USED IN EXTERIOR STR UCTURE OR EXP OSED TO WEATHER S HAL L B E S T A I N L E S S S T E E L OR H OT -D I P G A LV A N I Z E D . F A ST EN E R S I N P R E SE R V A TI V E T R E A T E D W OO D O R F IR E R E TAR DA N T TREATED WOOD SHALL BE OF HOT DIPPED ZINC COATED GALVANIZED STEEL OR STAINLESS STEEL. 26. ALL EXTERIOR WOOD MEMBERS (I.E. PLYWOOD, LUMBER, TIMBER,NAILERS, ETC.) SHALL BE CLASSIFIED FOR PRESSURE TREATED OR EXTERIOR GRADE DATE: P.M.: DRAWN BY: JOB NO.: 30211 Avenida de las Banderas, Suite 200, Rancho Santa Margarita, California, 92688 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D E SI GN B U I L D CNI UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT REV DATE REMARKS M.A. ISSUED FOR PERMIT12.17.20240 07.13.2025 20241149 ISSUED PER CITY PERMIT07.13.20251 S1.21 TYPICAL WOOD DETAILS 07/15/2025 EXP. 06-30-2026 1 W SCALE:NTS. OPNG. IN ROOF OR FLOOR W2 SCALE:NTS. SCALE:NTS. 3 W 5 SCALE:NTS. HIP TO KING POST CONNECTION FILLER SIMPSON MTS12 STRAP AT EA. SIDE OF BEAM HIP BEAM PER PLAN POST PER PLAN SIMPSON MTS STRAP SHEATHING PER PLAN W SHEAR TRANSFER AT ROOF SCALE:NTS. W7 6 SCALE:NTS. WSHEAR TRANSFER AT ROOF TO INTERIOR SHEAR WALL 2x BLK'G @ 48" O.C. 2 BAYS (TYP.) ROOF RAFTER PER PLAN A35 PER SHEAR WALL SCHED. 2xBLK'G @48" O.C 2 BAYS(TYP.) SHEAR WALL PER PLAN 2xBLK'G @48" O.C. 2 BAYS(TYP.) SIMPSON A35 2x STUD WALL PER PLAN CEILING JOIST PER PLAN SHEAR WALL PER PLAN DBL. 2x TOP PLATE ROOF SHEATHING PER PLAN B.N. 2x RIM JOIST SIMPSON LTP4 DBL. 2x TOP PLATECEILING JOIST PER PLAN A35 PER SHEAR WALL SCHED. SILL PLATE PER SHEAR WALL SCHED. E.N E.N E.N 2x STUD WALL PER PLAN RIDGE BOARD CONNE.9 W SCALE:NTS. BEAM PER PLAN BC COLUMN CAP RIDGE BEAM PER PLAN ROOF RAFTER PER PLAN SHT'G PER PLAN HANGER PER PLAN HHRC CONNECTION HIP BEAM PER PLAN BC COLUMN CAP CONNECTION OF KING POST ON BEAM SIMPSON HANGER SIMPSON HHRC SIMPSON BC SIMPSON MSTA24 @EACH RAFTER SIMPSON BC SCALE:NTS. WFLAT SLEEPER DETAIL4 SHEATHING EDGE AT BOTTOM PLATE (SINGLE ROW AND DOUBLE ROW OF FASTENERS) 3 4" SPACING SINGLE ROW OF FASTENERS SPACING 3 4" SHEATHING EDGE AT TOP PLATE (SINGLE ROW AND DOUBLE ROW OF FASTENERS) SINGLE ROW OF FASTENERS DOUBLE ROW OF FASTENERS 1 2" 1 2" SPACING SPACING DOUBLE ROW OF FASTENERS 1 2" 1 2" SPACING SPACING DOUBLE ROW OF FASTENERS SINGLE ROW OF FASTENERS 1 2" 1 2" SPACING SPACING SPACING 3 4" SPACING (FOR SHEAR WALL DESIGN) 3 4"A - SECTION A 3 4" SPACING (SINGLE ROW SHOWN) PANEL EDGE PANEL EDGE PANEL EDGE PANEL EDGE BLOCKING, SAME SPECIES AS TOP AND BOTTOM PLATES (2xFLATWISE SHOWN) INCREASE STUD NAILING FOR UPLIFT (EACH SIDE OF HORIZONTAL JOINT) INCREASE STUD NAILING FOR UPLIFT (EACH SIDE OF HORIZONTAL JOINT) PANEL EDGE PANEL EDGE PANEL EDGE PANEL EDGE SHEATHING SPLICE PLATE PANEL EDGE SHEATHING SPLICE PLATE 2x FLAT WISE BLOCKING SHEATHING SPLICE PLATE, SAME THICK. AND FACE GRAIN ORIENTATION AS SHEATHING PANEL ATTACHMENT PANEL SPLICE OCCURRING OVER HORIZONTAL FRAMING MEMBER PANEL SPLICE OCCURRING ACROSS STUDS SHEATHING SPLICE PLATE (ALTERNATE DETAIL) SHEAR PANEL ATTACHMENT AND SPLICE W'≥MAX. (WIDTH, HEIGHT, 12'') NOTES: OPENINGS IN HOR. DIAPHRAGMS IN SEISMIC DESIGN CATEGORIES B, C, D AND E W/ A DIMENSION THAT IS GREATER THAN 4 FT (1219 MM) SHALL BE CONSTRUCTED W/ METAL TIES AND BLK'G IN ACCORDANCE W/ THIS SECTION. METAL TIES SHALL BE NOT LESS THAN 0.058" [1.47 MM (16 GALV. GAGE)] IN THICK. BY 1 1/2" (38 MM) IN WIDTH AND SHALL HAVE A YIELD STRESS NOT LESS THAN 33,000 PSI (227 MPA). BLK'G SHALL EXTEND NOT LESS THAN THE DIMENSION OF THE OPNG. IN THE DIRECTION OF THE TIE AND BLK'G. TIES SHALL BE ATTACHED TO BLK'G IN ACCORDANCE W/ THE MANUFACTURER'S INSTRUCTIONS BUT W/ NOT LESS THAN EIGHT 16d COMMON NAILS ON EA. SIDE OF THE HEADER-JOIST INTERSECTION. FLOOR OPENING w, 48" MAX. 24 " M A X . TIE AND BLK'G EQ. TO THE DIMENSION OF OPNG. 4x BLK'G AT STRAP LOCATION (TYP.) JOISTS OR RAFTERS TIE AND BLK'G EQ. TO THE DIMENSION OF OPNG. HANGER PER PLAN CONT. CS14 STRAP W/ BLK'G MIN. W/2 BEYOND OPNG. DOUBLE CONT. ROOF RAFTER W/ E.N.W' W' SIMPSON HOLDOWNSIMPSON A35SIMPSON MSTA SIMPSON H2.5A E.N. ROOF RAFTER SHEATHING PER PLAN H2.5A INSTALLED AT 48" O.C. (OR AT PLYWOOD EDGE JOINTS) (2) 2x BLK'G MIN. SEE SHEAR WALL PER ROOF PLAN STRAP PER PLAN HOLDOWN PER PLAN TOP PLATE STUD WALL PER PLAN UNO. PER SHEAR WALL SCHED. NOTE: FOR MORE CONNE. SEE DETAIL 1/S1.01 SHEAR WALL BTWN. CEILING W SCALE:NTS. A35 @ UNO ON SHEAR WALL SCHEDULE 8 DOUBLE JOIST 2x BLOCKING(2 BAYS) @ 48" O.C. W/ (3)16d EACH END ROOF RAFTER PER PLAN SIMPSON A35 @ 16"O.C. U.N.O. SEE SHEAR WALL SCHEDULE CEILING JOIST PER PLAN ROOF SHEATHING PER PLAN 2x CANTILEVERED JOIST PERPENDICULAR TO ROOF RAFTER @ 16"O.C. W/ (3)-40d NAILING 2x SOLID BLOCKING W/ SIMPSON A35 @ 16" O.C. U.N.O. SEE SHEAR WALL SCHEDULE E.N B.N LESSER OF ("L" OR 2'-0")L" 2x BLK'G @48" O.C. (2 BAYS) 4x BLK'G DBL. 2x TOP PLATE STUD WALL PER PLAN UNO. PER SHEAR WALL SCHED. SHEAR WALL PER PLAN 2x RIM 2x LEDGER W/(2) SDWS22400DB EA. STUD E.N 16d @ 4" O.C. H2.5A INSTALLED AT 48" O.C. (OR AT PLYWOOD EDGE JOINTS) A34 W/SCREW ROOF RAFTER PER PLAN USE 3-10d TOENAIL FOR RAFTER TO RIDGE CONNECTION RIDGE BOARD PER PLAN FILLER B.N. SIMPSON MSTA24 @EA. RAFTER ROOF SHEATHING PER PLAN SIMPSON A35 ROOF SHEATHING A35 CLIP @EACH JOIST 3-16d @EACH RAFTER FLAT SLEEPER PER PLAN 2X BLK'G@16" O.C. ROOF RAFTER PER PLAN ROOF SHT'G PER PLAN (2)A35 CLIP @ EACH JOIST 3-16d FOR EACH FLAT SLEEPER @EACH RAFTER DOUBLE FLAT SLEEPER PER PLAN ROOF RAFTER PER PLAN ROOF SHT'G PER PLAN ROOF RAFTER/ TRUSS PER PLAN ROOF SHEATHING PER PLAN ROOF RAFTER/TRUSS PER PLAN 2X BLK'G@16" O.C. B.N. B.N. SIMPSON MSTA (OPTION 1) SIMPSON A34 W/SCREW DOUBLE JOIST 2x BLOCKING (2 BAYS) @ 48" O.C. W/ (3)16d EACH END ROOF RAFTER PER PLAN SIMPSON A35 @ 16"O.C. U.N.O. SEE SHEAR WALL SCHEDULE 2x CANTILEVERED JOIST PERPENDICULAR TO ROOF RAFTER @ 16"O.C. W/ (3)-40d NAILING 2x SOLID BLOCKING W/ SIMPSON A35 @ 16" O.C. U.N.O. SEE SHEAR WALL SCHEDULE E.N B.N LESSER OF ("L" OR 2'-0")L" DBL. 2x TOP PLATE STUD WALL PER PLAN UNO. PER SHEAR WALL SCHED. SHEAR WALL PER PLAN 2x RIM H2.5A INSTALLED AT 48" O.C. (OR AT PLYWOOD EDGE JOINTS) CEILING JOIST PER PLAN 2x 4 @ 48" O.C. (3)10d NAILS SILL PLATE PER SHEAR WALL SCHED. DBL. 2x TOP PLATE A35 PER SHEAR WALL SCHED. 2x BLK'G @48" O.C. (2 BAYS) STUD WALL PER PLAN UNO. PER SHEAR WALL SCHED. PLYWD. JOINT W/ 1/2" GAP ROOF SHEATHING PER PLAN E.N E.N (OPTION 2) DATE: P.M.: DRAWN BY: JOB NO.: 30211 Avenida de las Banderas, Suite 200, Rancho Santa Margarita, California, 92688 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D E SI GN B U I L D CNI UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT REV DATE REMARKS M.A. ISSUED FOR PERMIT12.17.20240 07.13.2025 20241149 ISSUED PER CITY PERMIT07.13.20251 S1.22 TYPICAL WOOD DETAILS 07/15/2025 EXP. 06-30-2026 SCALE:NTS. 2 W SCALE:NTS. FLOOR TO FLOOR CONNECTION BY MSTA & MSTC STRAP W SCALE:NTS. 1 5 W SCALE:NTS. JOISTS PERPENDICULAR TO INTERIOR WALL3 SCALE:NTS. 1 BUILT UP POST SHEAR WALL DETAILS AT INTERSECTIONS7 W SCALE:NTS. BEARING/NON-LOAD BEARING WALL AT INTERSECTIONS DETAIL6 W SCALE:NTS. STRAP SPLICE LENGTH AND FASTENERS SHEARWALL PENETRATIONS W SCALE:NTS. 9 CUTTING, NOTCHING AND BORING IN LUMBER BEAMS AND RAFTERS W SCALE:NTS. 8 SCALE:NTS. 4 WFLUSH BEAM PERPENDICULAR TO WALL DETAIL SIMPSON A34 PROVIDE SIMPSON A34 EA. SIDE OF BEAMS BEAM PER PLAN POST PER PLAN DBL. TOP PLATE MOSEL NO.GA. STRAP LAP SPLICE MINIMUM FASTENERS PER SPLICE MIN SPLICE LENGTH, LSP (IN.) CMST12 12 (22) 0.148 x 2 1/2 21 CMST14 14 (15) 0.148 x 2 1/2 15 CMSTC16 16 (11) 0.148 x 2 1/2 10 CS14 14 (6) 0.148 x 2 1/2 9 CS16 16 (5) 0.148 x 2 1/2 8 CS20 20 (5) 0.148 x 2 1/2 8 CSHP18 18 (7) 0.148 x 2 1/2 9 CSHP20 20 (6) 0.148 x 2 1/2 8 SPLICE LENGTH AND FASTENERS PER TABLE BELOW LSP NOTE: 1. SEE PP. 266-267 FOR STRAPS AND TIES GENERAL NOTES. 2. 0.148" X 2 1/2" NAILS CAN BE RAPIACED BY 0.148"X 3 1/4" NAILS.NO OTHER NAIL SUBSTITUTION IS ALLOWED FOR LAP SPLICES 3. REFER TO THE APPLICABLE CODE FOR MIN. EDGE DISTANCE AND MIN. END DISTANCE. 4. NO STRAP MODIFICATION IS ALLOWED AND THE SPLICE MUST MEET BOTH THE MIN. NUMBER OF NUMBER OF FASTENERS AND THE MIN. SPLICE LENGTH. MODEL NO. CLEAR SPAN (IN.) FASTENERS TOTAL (IN.)ALLOWABLE TENSION LOAD (DF/SP) MSTA49 18 (26) 0.148 x 2 1/2 2,020 MSTC28 18 (12) 0.148 x 3 1/4 1,150 MSTC40 18 (28) 0.148 x 3 1/4 2,690 MSTC52 18 (44) 0.148 x 3 1/4 4,225 MSTC66 18 (64) 0.148 x 3 1/4 5,850 MSTC78 18 (76) 0.148 x 3 1/4 5,850 MST37 18 (20) 0.162 x 2 1/2 2,460 MST48 18 (32) 0.162 x 2 1/2 3,950 MST60 18 (46) 0.162 x 2 1/2 6,235 MST72 18 (62) 0.162 x 2 1/2 6,730 FLOOR TO FLOOR TIE INSTALLATION SHOWING CU T L E N G T H CL E A R S P A N EN D L E N G T H EN D L E N G T H SHEATHING NOT SHOWN FOR CLARITY. PROVIDE MIN. 1 1/6" END DISTANCE FOR CS AND CMST EQUAL NUMBER OF SPECIFIED NAILS IN EA. END ADDITIONAL NAILS ARE REQUIRED IN THE RIM BOARD AREA (2)2x T.PLATE 2x STUDS JOIST PER PLAN JOIST PER PLAN A35 @16" NAILING BETWEN JOISTS (7)16d MIN. COMMON NAILS 2x BLK'NG 12" MIN. LAP 3-8d COMMON TOENAIL EACH JOIST SIMPSON A35 (3)2x6 (3)2x4 4x6 WITH (2)2x6 4x4 WITH (2)2x4 (2)2x6 (2)2x4 4x6 WITH 2x6 4x4 WITH 2x4 2 1 2" 6" 6" 1 1 2"1 1 2" USE ROW OF STAGGERED 10d COMMON WIRE NAILS (D=0.148'' , L=3'') FOR 2-PLY 11 2" 31 2" 11 2" 2 1 2" 6" 6" 1 1 2"1 1 2" 11 2" 51 2" 11 2" 312" 8" 8" 11 2" 11 2"11 2" 11 2" 21 2" 11 2" 31 2" 11 2" 312" 8" 8" 11 2" 11 2"11 2" USE ROW OF STAGGERED 30d COMMON WIRE NAILS (D=0.207'', L=4 1/2'') FOR 3-PLY (4)2x6 11 2" 51 2" 11 2" 312" 8" 8" 11 2" 11 2" 11 2" 11 2" 21 2" 11 2" USE ROW OF STAGGERED 60d COMMON WIRE NAILS (D=0.238'' , L=6'') FOR 4-PLY 11 2" 31 2" 11 2" 312" 8" 8" 11 2" 11 2" 11 2"11 2" (4)2x4 11 2" 51 2" 11 2" 312" 6" 6" 11 2" 31 2" 11 2" 21 2" USE ROWS OF STAGGERED 30d COMMON WIRE NAILS (D=0.207'' , L=4 1/2'') FOR 4X WITH (1)2X 11 2" 31 2" 11 2" 312" 6" 6" 31 2" 11 2" 11 2" 51 2" 11 2" 11 2" 21 2" 312" 8" 8" 31 2" 11 2" 11 2" USE ROW OF STAGGERED 60d COMMON WIRE NAILS (D=0.238'' , L=6'') FOR 4X WITH (2)2X 312" 8" 8" 31 2" 11 2" 11 2" 11 2" 31 2" 11 2" 11 2" 51 2" 11 2" 11 2" 21 2" NOTE: PROVIDE REQD. DOUBLE STUDS OR POSTS WHERE HOLDOWNS OCCUR PLAN VIEW 16d@12" O.C. STAGGER 16d@12" O.C. 2x STUDS @16" O.C. UNO CONTINUE SHEAR WALL PANEL TO HOLDOWNS AS SHOWN SHEATHINGG ON ONE SIDE 16 " M A X . UN O . PE R P L A N SHEATHING ON BOTH SIDES 16" MAX. UNO. PER PLAN E.N. @6" O.C. UNO PER SHEAR WALL SCHED.COMPRESSION POST W/ E.N. @6" O.C. UNO PER SHEAR WALL SCHED. 2x STUD 2x STUD HOLDOWN PER PLAN HOLDOWN PER PLAN HOLDOWN PER PLAN HOLDOWN PER PLAN 2x STUD 2x STUD COMPRESSION POST W/ E.N. @6" O.C. UNO PER SHEAR WALL SCHED. COMPRESSION 2XSTUD W/ E.N. @6" O.C. UNO PER SHEAR WALL SCHED. 30d@6" O.C. COMPRESSION POST W/ E.N. @6" O.C. UNO PER SHEAR WALL SCHED. 48" TYP. 2xBLK'G TYP. 4 1 2" SQ. TO 9" SQ. BLK'G AND E.N. REQ'D 4 1 2" SQ. NO. BLK'G AND E.N. REQ'D 48" TYP. NOTE: 1. HOLES UP TO 4 1 2" SQ. TO NOT RECUIRE BLK'G & E.N. 2.HOLES FROM 4 1 2" SQ. TO 9" SQ. RECUIRE BLK'G & E.N. 3.HOLES LARGER THAN 9" SQ. ARE NOT ALLOWED. 4.HOLES SIZE INCLUDES THE LENGHT OF THE OVERCUT. 5.MAX ACCUMULATED LENGHT OF OPENINGS SHALL NOT EXCEED 20 PERCENT OF THE WALL LENGTH. 6.RECOMMEND CIRCULAR BORED HOLES OR RADIUS CORNER CUTS (TO REDIUS STRESS CONCENTRATIONS). 16 " 45 ° 16 " D/ 6 M A X . D/ 3 M A X . 2" M I N . D/ 4 M A X . A T E N D S SQUARE HOLES AND NOTCHED NOT RECOMMENDED D/ 6 M A X . MAX. LENGTH=D/3 OUTER 1/3 OF SPAN MIDDLE 1/3 OF SPAN: NOTCHING NOT PERMITTED OUTER 1/3 OF SPAN NOTES: FOR LUMBER BEAM: 1. UNLESS PERMITTED BY MANUF. , CUTS, NOTCHES AND HOLES BORED IN TRUSSES, STRUCTURAL COMPOSITE LUMBER, STRUCTURAL GLUE-LAMINATED MEMBERS,CROSS-LAMINATED TIMBER MEMBERS OR I JOISTS SHALL NOT BE PERMITTED. 2. CLEAR DISTANCE BTWN. THE HOLES SHALL NOT BE LESS THAN THE GREATEST OF TWO TIMES THE ADJACENT HOLES, D/3 AND 2". 3. ALL NOTCHES SHOULD BE SEALED W/ A WATER-REPELLENT SEALER, IMMEDIATELY AFTER CUTTING. 4. ROUND THE SQUARE CORNER OF THE NOTCH TO A MIN. 1/2" RADIUS. 5. THE TENSION SIDE OF MEMBERS W/ 4" OR GREATER IN NOMINAL THICK. SHALL NOT BE NOTCHED EXCEPT AT THE ENDS OF THE MEMBERS. FOR ENGINEERED WOOD BEAM(LVL,PSL,LSL): 1. SEE MANUFACTURERS' CATALOGUES/ SPECIFICATIONS. D JOIST DEPTH AT TAPER CUT D/ 4 M A X . D NOT LESS THAN 3 1/2" CANTILEVER NOT TO EXCEED 24" 2" M I N . 2" MIN.Ø≤D/3 2" M I N JOIST SIZE MAX. HOLE MAXIMUM NOTCH DEPTH MAXIMUM END NOTCH 2x4 NONE NONE NONE 2x6 1 1/2 7/8 1 3/8 2x8 2 3/8 1 1/4 1 7/8 2x10 3 1 1/2 2 3/8 2x12 3 3/4 1 7/8 2 7/8 D/4 M A X . 2" M I N . D W DATE: P.M.: DRAWN BY: JOB NO.: 30211 Avenida de las Banderas, Suite 200, Rancho Santa Margarita, California, 92688 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D E SI GN B U I L D CNI UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT REV DATE REMARKS M.A. ISSUED FOR PERMIT12.17.20240 07.13.2025 20241149 ISSUED PER CITY PERMIT07.13.20251 S1.23 TYPICAL WOOD DETAILS 07/15/2025 EXP. 06-30-2026 1 W SCALE:NTS. EXT. WALL ELEVATION (FOR SHEARWALL, SEE SHEARWALL DETAIL) 2 MIN. DIM. OF HEADER FOR NON-LOAD BRG. WALL NOTES: 1. HEADER SCHEDULE SHALL NOT BE USED AT LOCATION WHERE HEADERS SUPPORT OTHER STRUCTURAL ELEMENTS SUCH AS BRG. WALLS, BEAMS, OR POSTS. 2.SPANS OVER 12' TO BE SPECIFICALLY SHOWN ON THE PLANS. 3.(2)2X OR (3)2X MAY BE USED IN-LIEU OF 4X & 6X MEMEBERS RESPECTIVELY. W SCALE:NTS. 3 W SCALE:NTS. POST SPLICE CONNE. DETAIL POST SEE PLAN SIMPSON A34 W/ SDS SCREW EA. SIDE JOIST SEE PLAN FOR DIRECTION POST SEE PLAN (2)2x TOP PLATE PROVIDE SOLID BRG. UNDER POST/JACK STUD SILL PLATE 2x STUD WHERE OCCUR 2x STUD WHERE OCCUR SIMPSON A34 OPTION I NOTE: 1. NAILS CONNECTING SIMPSON DTC CLIP TO JOIST SHALL BE HAMMERED NEARLY FLUSH, NOT COMPLETELY FLUSH. NAILS CONNECTING SIMPSON DTC CLIP TO TOP PLATE SHALL BE HAMMERED FLSUH. 2. AT CONTRACTOR'S OPTION PROVIDE (1)2x TOP PLATE AND (1)1x TOP PLATE IN LIEU OF (2)2x TOP PLATES. GAP SHALL BE GREATER THE 1/2" BUT LESS THAN OR EQUAL TO 1 IN. 3. 2x BLK'G AT PLYWOOD JOINTS OR WHERE WALL EXCEEDS 10'-0" IN HEIGHT SIMPSON DTC NON-LOAD BRG. PARTITIONS CONNE. 16d@48" O.C. 4 W SCALE:NTS. SHEATHING PER PLAN NON-LOAD BRG. STUD WALL (2) 2 X SILL PLATE OR 3X SILL PLATE (2)2x TOP PLATE SEE NOTE #2 16d@48" O.C. SHEATHING PER PLAN NON-LOAD BRG. STUD WALL (2) 2 X SILL PLATE OR 3X SILL PLATE (2)2x TOP PLATE SEE NOTE #2 SIMPSON "DTC" CLIP @24"OC w/ (4)8d NAILS TO BASE AND (2)8d NAILS TO JOIST SEE NOTE 1 10d@4" O.C. AT BLK'G PROVIDE 2x BLK'G (DEPTH TO SUIT) BTWN. WOOD JOISTS @24" O.C. (MAX.) 2x STUD SEE ARCH. FOR SIZE AND SPACING 2x STUD SEE ARCH. FOR SIZE AND SPACING 1" C L R . 1" C L R . NON-LOAD BRG. PARTITIONS CONNE.5 W SCALE:NTS. NOTE: 1. AT CONTRACTOR'S OPTION PROVIDE (1)2x TOP PLATE AND (1)1x TOP PLATE IN LIEU OF (2)2x TOP PLATES. GAP SHALL BE GREATER THE 1/2" BUT LESS THAN OR EQUAL TO 1 IN. 2. 2x BLK'G AT PLYWOOD JOINTS OR WHERE WALL EXCEEDS 10'-0" IN HEIGHT 3. INSTALL SDPW PER SIMPSON RECOMMENDATION. OPTION II 16d@48" O.C. SHEATHING PER PLAN NON-LOAD BRG. STUD WALL (2) 2 X SILL PLATE OR 3X SILL PLATE 16d@48" O.C. SHEATHING PER PLAN NON-LOAD BRG. STUD WALL (2) 2 X SILL PLATE OR 3X SILL PLATE SIMPSON SDPW SCREW @ 24" O.C. PROVIDE 2x BLK'G W/ (3)10d FROM PLYWOOD 2x STUD SEE ARCH. FOR SIZE AND SPACING (2)2x TOP PLATE1/ 2 " M I N . 3 / 4 " M A X . GA P 3 4" OFFSET WHERE NON-BRG. STUD WALL OCCURS ABV. ONLY, PROVIDE 2X6@24" O.C. IN LIEU OF 2X BLOCK NON-LOAD BRG. STUD WALL SIMPSON SDPW SCREW @ 24" O.C. 1/ 2 " M I N . 3 / 4 " M A X . GA P 3 4" OFFSET 3/ 4 " M I N . SHEATHING PER PLAN (2)2x TOP PLATE OR (1)2x + (1)1x TOP PLATES SIMPSON SDPW SCREW USE SDPW19600 FOR (2)2x TOP PLATES AND SDPW14600 FOR (1)2x + (1)1x TOP PLATES 1/ 2 " M I N . 3 / 4 " M A X . GA P 3 4" OFFSET 3/ 4 " M I N . 3/8" PRE-DRILLED HOLE THROUGH TOP PLATES ONLY SUPPORTING MEMBER OVERHEAD 10 " SIMPSON THDB62100H SIMPSON HOLDOWNSIMPSON LSTHSIMPSON A35 SIMPSON CCQANCHOR ROD 1" MIN. THREAD 12 " M I N . BP/BPS 5/8" (3"x3"x1/4") SIMPSON CBSIMPSON A34 NOTE: 1. FOR CLARITY, ONLY TYPICAL CONNECTIONS ARE SHOWN *NOT MORE THAN SPECIFIED SPACING FOR ANCHOR ROD ON SHEAR WALL SCHEDULE. 2. BEARING WALLS SHALL BE SHEATHED ON NOT LESS THAN ONE SIDE OR BRIDGING SHALL BE INSTALLED NOT GREATER THAN 4 FEET APART MEASURED VERTICALLY FROM EITHER END OF THE STUD. 2x BLKG SHALL BE PROVIDED AT PLYWD JOINTS FOR ALL WALLS. 3. THE HOLE IN THE PLATE WASHER IS PERMITTED TO BE DIAGONALLY SLOTTED WITH A WIDTH OF UP TO 3/16" LARGER THAN THE BOLT DIAMETER AND A SOLT LENGTH NOT TO EXEED 1-3/4",PROVIDED THAT A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND THE NUT. 4. FOR THE BALANCE OF NAILING, SEE CBC TABLE 2304.10.2 ON SHEETS S0 SERIES. 4 1/2" MIN. 12" MAX. TYP. AT ALL DISCONTINUOUS SILL PLATES* TYP. DBL TOP PLATE FACE NAILING 16d@16" O.C. (4)16d AT CORNERS PARTITIONS, TYP. (3)8d COMMON TOENAIL EA. JOIST FLOOR OR ROOF SHEATHING SEE PLAN BLK'G OR CONTINUOUS RIM JOIST (4)8d COMMON TOENAIL 16d@12"OC AT CORNER STUDS CORNER STUDS PER TYP. DETAIL TYP. EXT. SHEATHING W/ EN. @ 6" O.C. & FINAL @ 12" O.C., UNO DOUBLE 2x JACK STUD & KING STUDS FOR SPANS GREATER THAN 6'-0" STUD WALL PER PLAN UNO. PER SHEAR WALL SCHED. 16d @ 12"OC AT DBL KING STUD & JACK STUD SEE NOTE 2 DOUBLE 2x SILL FOR OPNG. OVER 6'-0" PL. SPLICE POST POST CAP SEE PLAN SIMPSON A35, SHEAR TRANSFER CLIPS OR NAILING SEE PLAN & SHEARWALL TABLE (2)2x TOP PLATE 8x D A MI N . 4' MAX. UNO IN SHEARWALL SCHEDULE L<8'-1" SIMPSON A34 EA. END SIMPSON A34 EA. END PL. SPLICE 4'-0" MIN. SIMPSON A34 EACH END C.L. SPLICE AT UPPER PLATE C.L. SPLICE AT LOWER PLATE (2) SIMPSON MSTA49 (2)TOP PLATE SPLICE-OPTION 1 16-16d NAIL ON EACH SIDE THDB62100H BP/BPS 5/8-3 SIMPSON A34 FOUNDATION ATTACH JACK STUD TO KING STUD W/ 16d@12" OC STAGGERED, TYP. SIMPSON A34 EACH END SIMPSON A34 EACH END SIMPSON CB SIMPSON A34 SIMPSON A34 W/ SD SCREW 2x WINDOW SILL WHERE OCCURS (2)2x SILL AT OPNG. WIDER THAN 4'-0") 2x WINDOW SILL WHERE OCCURS (2)2x SILL AT OPNG. WIDER THAN 4'-0") SIMPSON A35 SOLID BLOCKING UNDER ABOVE POSTS SOLID BLOCKING UNDER ABOVE BEAMS SOLID BLK'G UNDER ABV. POSTS (2)10d TOE NAILS (ADD SIMPSON A34 AT OPENING WIDER THAN 6'-0") SIMPSON A34 W/ SD SCREW,TYP. 4 1/2" MIN. 12" MAX.* 4 1/2" MIN. 12" MAX.* 4 1/2" MIN. 12" MAX. TYP. AT ALL DISCONTINUOUS SILL PLATES* 4 1/2" MIN. 12" MAX. TYP. AT ALL DISCONTINUOUS SILL PLATES* SIMPSON A34 SIMPSON A35 4 1/2" MIN. 12" MAX. TYP. AT ALL DISCONTINUOUS SILL PLATES* PROVIDE STUD BELOW SPLICE PROVIDE STUD BELOW SPLICE OPENING OPENING OPENING OPENING OPENING SIMPSON MSTA49 ON EACH JACK STUD UNO PER PLAN(TYP.) TYPICAL (2)16d END NAILS 2x PLATE W/(4)16d 2x BLK'G W/(2)16d HEADER SCHEDULE (SEE NOTES BELOW) UNLESS NOTED OTHERWISE ON PLANS OPG. WIDTH MIN. HEADER SIZE MIN. NUM. OF FULL HEIGHT STUD MIN. NUM. OF JACK STUD NON-BRG.INT. WALL ≤4'-0"4x4/4x6 FLAT 2 2 4'-0"≤W≤6'-0"4x6/6x6 2 2 6'-0"≤W≤8'-0"4x8/6x8 2 2 8'-0"≤W≤10'-0"4x10/6x10 3 3 10'-0"≤W≤12'-0"4x12/6x12 3 3 BEAM PER PLAN (4)16d COMMON NAIL FOR 2X KING (4)40d COMMON NAIL FOR 4X KING (4)SDS25800 SCREW FOR 6X KING TYP. TOP PLATE SPLICE-OPTION 2 MSTC40 WITH 26-10d NAILS ON EACH SIDE SIMPSON MSTA49 EA. SIDE (2)16d EA. SIDE OF SPLICE A - PL. SPLICE 16-16d NAIL (OPTION 1) PL. SPLICEPL. SPLICE MSTC40 (OPTION 2) A - SECTION A: TOP PLATE SPLICE-OPTIONS 1 AND 2 4 1 2" MIN. 12" MAX. 4' MAX. UNO IN SHEARWALL SCHEDULE 4 1 2" MIN. 12" MAX. DATE: P.M.: DRAWN BY: JOB NO.: 30211 Avenida de las Banderas, Suite 200, Rancho Santa Margarita, California, 92688 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D E SI GN B U I L D CNI UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT REV DATE REMARKS M.A. ISSUED FOR PERMIT12.17.20240 07.13.2025 20241149 ISSUED PER CITY PERMIT07.13.20251 S1.24 TYPICAL WALL DETAILS 07/15/2025 EXP. 06-30-2026 W SCALE:NTS. 1 FLOOR OR ROOF DIAPHRAGM SHEATHING REQUIREMENTS DETAIL A PLAN NOTE: THE LOWER ENDS OF CROSS BRIDGING SHALL BE DRIVEN UP AND NAILED AFTER THE SHEATHING HAS BEEN NAILED. JST. PER PLAN FIELD NAILING B.N. AT ALL CONT. PANEL EDGES PROVIDE 2x BLK'G PER DETAIL A AT BLOCKED DIAPHRAGM DISCONT. EDGE NAILING B.N. SHEATHING SEE PLAN STAG G E R END J O I N T S 4'-0" T Y P . 2'-0" M I N . METAL CROSS BRIDGING PER TJI MANUFACTUREREDGE NAILING TJI PER PLAN 2x4 CONT. W/ 16d@12" O.C. RAFTER OR JOIST. BEYOND AT LAP SPLICE EDGE NAILING SHEATHING JOINT SHEATHING JOINTEDGE NAILING 2x4 FLAT BLK'G W/ (2)10d TOENAILS EA. END RAFTER OR JOIST PER PLAN2x BRIDGING (FULL HEIGHT) 1 1/2" EDGE NAILING 5/16" MAX. 2 1/2" EDGE NAILING 13/16" MAX. 3" EDGE NAILING 1-1/16" MAX.TWO 2x-FRAMING3x-FRAMING2x-FRAMING 1/8" GAP TYP. 3/8" MIN. TYP. DETAIL B DETAIL C DETAIL D 1/8" GAP TYP. 3/8" MIN. TYP. 1/8" GAP TYP. 3/8" MIN. TYP. DETAIL E NOTE: ALL BLOCKED AND UNBLOCKED DIAPHRAGMS (ROOF AND FLOOR) SHALL BE CONSTRUCTED AS FOLLOWS: 1. REVIEW THE PLAN NOTES AND DRAWINGS FOR ADDITIONAL REQUIREMENTS OF FLOOR AND ROOF CONSTRUCTIONS. 2. WOOD STRUCTURAL PANELS SHALL CONFORM TO THE REQUIREMENTS FOR THEIR TYPE IN DOC PS 1 OR DOC PS2. 3. WHERE DIAPHRAGMS ARE DESIGNATED AS BLOCKED, ALL JOINTS IN SHEATHING SHALL OCCUR OVER AND BE FASTENED TO COMMON FRAMING MEMBERS OR COMMON BLK'G. THE SIZE AND SPACING OF FASTENERS AT WOOD-FRAME DIAPHRAGM BOUNDARIES AND PANEL EDGES SHALL BE AS SPECIFIED ON THESE DWGS. 4. PANELS SHALL NOT BE LESS THAN 4' X 8' EXCEPT AT BOUNDARIES AND CHANGES IN FRAMING WHERE MIN. PANEL DIMENSION SHALL BE 24" UNLESS ALL EDGES OF THE UNDERSIZED PANELS ARE SUPPORTED BY AND FASTENED TO FRAMING MEMBERS OR BLK'G. INDIVIDUAL SHEET OF SHEATHING SHALL NOT BE LESS THAN 2'-0" IN THEIR LEAST PLAN DIMENSION NOR LESS THAN 8 SQ.FT. IN AREA. 5. FOR UNBLOCKED DIAPHRAGMS, THE BLK'G BTWN. SUPPORTING STRUCTURAL MEMBERS AT PANEL EDGES IS NOT REQD. 6. NAILS SHALL BE LOCATED AT LEAST 3/8" FROM THE EDGES OF PANELS.MAX. NAIL SPACING AT PANEL EDGES SHALL BE 6" ON CENTER. 7. NAILS ALONG INTERMEDIATE FRAMING MEMBERS AND BLK'G FOR PANELS SHALL BE THE SAME SIZE AS INSTALLED AT THE PANEL EDGES. 8. MAX. NAIL SPACING SHALL BE 6" ON CENTER WHEN SUPPORT SPACING OF 48" ON CENTER IS SPECIFIED AND 12" ON CENTER FOR CLOSER SUPPORT SPACINGS. 9. THE WIDTH OF THE NAILED FACE OF FRAMING MEMBERS AND BLK'G SHALL BE 2" NOMINAL OR GREATER AT ADJOINING PANEL EDGES EXCEPT THAT A 3" NOMINAL OR GREATER WIDTH AT ADJOINING PANEL EDGES AND STAGGERED NAILING AT ALL PANEL EDGES ARE REQD. WHERE: 9.1. NAIL SPACING OF 2-1/2" ON CENTER OR LESS AT ADJOINING PANEL EDGES IS SPECIFIED, OR 9.2. 10D COMMON NAILS HAVING PENETRATION IN-TO FRAMING MEMBERS AND BLK'G OF MORE THAN 1-1/2" ARE SPECIFIED AT 3" ON CENTER OR LESS AT ADJOINING PANEL EDGES. 10. SPECIFIED STRAPS OR HOLDOWN SYSTEM SHALL BE USED TO SPLICE THE WALL TOP PLATES, SILL/BOT PLATES, BEAMS OR OTHER DRAG ELEMENTS. SHEATHING SHALL NOT BE USED TO SPLICE THE PLATES OR BEAMS. 11. TONGUE-AND-GROOVE SHEATHING SHALL BE INSTALLED W/ THE TONGUES UP ON SLOPED OR PITCHED ROOFS W/ PATTERN FACES DOWN. 12. WHERE RAFTER OR JOIST. LAP SPLICE OCCURS AND PLYWOOD JOINT IS CONTINUES,SEE DETAIL B. BRIDGING/BLK'G IS REQD. AT 96" O.C.MAX. SEE DETAILS C AND D. 13. SHEATHING NAILS OR OTHER APPROVED SHEATHING CONNECTORS SHALL BE DRIVEN SUCH THAT THEIR HEAD OR CROWN IS FLUSH W/ THE SURFACE OF THE SHEATHING OVER-DRIVEN NAILS SHALL NOT BE PERMITTED AND SHALL BE DEEMED UNSATISFACTORY. 14. AT UNBLOCKED DIAPHRAGMS, NAIL SPACING AT DIAPHRAGM BOUNDARIES AND SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6” O.C.AND FIELD NAILING SHALL NOT BE SPACED MORE THAN 12”O.C. 15. AT BLOCKED DIAPHRAGMS,NAIL SPACING AT DIAPHRAGM BOUNDARIES AND AT ALL CONTINUES PANEL EDGES SHALL NOT BE MORE THAN 6 IN. NAIL SPACING AT ALL OTHER PANEL EDGES SHALL NOT BE MORE THAN 6 IN. CONT. PANEL JOINT IN BOTH DIRECTIONS SHALL NOT BE PERMITTED. FIELD NAILING SHALL NOT BE SPACED MORE THAN 12” O.C. STRAP DETAIL W SCALE:NTS. SHEATHING PER PLAN 2X RIM JST. BLK'G L L EDGE NAILING PER PLAN NOTE HEADER PER PLAN HORIZONTAL STRAP PER PLAN JACK PER PLAN SHEAR WALL PER PLAN 2X STUDS PER PLAN 16d @12" O.C. SHEATHING PER PLAN JST. PER PLANBLK'G L L HORIZONTAL STRAP PER PLAN POST PER PLAN SHEAR WALL PER PLAN 2X STUDS PER PLAN CONNECTION PER PLAN IF CONNECTION NOT MENTIONED IN PLAN SEE WALL SHEET ON 01/S1.24 KING PER PLAN CONNECTION PER PLAN BEAM PER PLAN 16d @12" O.C. SHEATHING PER PLAN JST. PER PLANBLK'G L L HORIZONTAL STRAP PER PLAN POST PER PLAN SHEAR WALL PER PLAN 2X STUDS PER PLAN CONNECTION PER PLAN BEAM PER PLAN 16d @12" O.C. A35 PER SHEARWALL SCHEDULE A35 PER SHEARWALL SCHEDULE A35 PER SHEARWALL SCHEDULE DBL. 2X TOP PLATE DBL. 2X TOP PLATE DETAIL A STRAP L (MIN. END LENGTH (IN.) INSTALLED IN EVERY HOLE) MIN. FASTENERS CAPACITY(lb) C16 11"(18) 0.148 x 2 1/2 1700 CS14 13"(24) 0.148 x 2 1/2 2390 CMSTC16 19"(48) 0.148 x 2 1 2 4610 CMST14 27"(58) 0.148 x 2 1/2 5770 CMST12 35"(76) 0.148 x 2 1/2 8320 DETAIL B DETAIL C 4 3'-0" 3'-0" SIMPSON CS14 STRAP UNO PER PLANTRUSS TOP CHORD OR ROOF RAFTER PER PLAN ROOF SHEATHING DRAG JACK TRUSS/ ROOF RAFTER W/ E.N. PER PLAN 2x BLK'G W/ E.N. SEE PLAN FOR LENGTH 3'-6" 3'-6" 2x ROOF RAFTER W/ E.N. SIMPSON CS14 STRAP UNO PER PLAN STUD OR POST PER PLAN ROOF SHEATHING ROOF JOISTS SIT ON WALL LINE OF E.N. W SCALE:NTS. 2 DRAG DETAIL ROOF SHEATHING 2xBLK'G @48" O.C 2 BAYS(TYP.) 2xBLK'G @48" O.C. 2 BAYS(TYP.) SIMPSON A35 2x STUD WALL PER PLAN CEILING JOIST PER PLAN 2x RIM JOIST DBL. 2x TOP PLATECEILING JOIST PER PLAN A35@16" O.C. W SCALE:NTS. 3 CEILING JOIST PARALLEL TO NON-SHEAR WALL 2 8d@6" O.C. DATE: P.M.: DRAWN BY: JOB NO.: 30211 Avenida de las Banderas, Suite 200, Rancho Santa Margarita, California, 92688 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D E SI GN B U I L D CNI UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT REV DATE REMARKS M.A. ISSUED FOR PERMIT12.17.20240 07.13.2025 20241149 ISSUED PER CITY PERMIT07.13.20251 ISSUED PER CITY PERMIT09.28.20252 S1.25 TYPICAL WOOD DETAILS 09/28/2025 EXP. 06-30-2026 W SCALE:NTS. 1 FLOOR OR ROOF DIAPHRAGM SHEATHING REQUIREMENTS DETAIL A PLAN NOTE: THE LOWER ENDS OF CROSS BRIDGING SHALL BE DRIVEN UP AND NAILED AFTER THE SHEATHING HAS BEEN NAILED. JST. PER PLAN FIELD NAILING B.N. AT ALL CONT. PANEL EDGES PROVIDE 2x BLK'G PER DETAIL A AT BLOCKED DIAPHRAGM DISCONT. EDGE NAILING B.N. SHEATHING SEE PLAN STAG G E R END J O I N T S 4'-0" T Y P . 2'-0" M I N . METAL CROSS BRIDGING PER TJI MANUFACTUREREDGE NAILING TJI PER PLAN 2x4 CONT. W/ 16d@12" O.C. RAFTER OR JOIST. BEYOND AT LAP SPLICE EDGE NAILING SHEATHING JOINT SHEATHING JOINTEDGE NAILING 2x4 FLAT BLK'G W/ (2)10d TOENAILS EA. END RAFTER OR JOIST PER PLAN2x BRIDGING (FULL HEIGHT) 1 1/2" EDGE NAILING 5/16" MAX. 2 1/2" EDGE NAILING 13/16" MAX. 3" EDGE NAILING 1-1/16" MAX.TWO 2x-FRAMING3x-FRAMING2x-FRAMING 1/8" GAP TYP. 3/8" MIN. TYP. DETAIL B DETAIL C DETAIL D 1/8" GAP TYP. 3/8" MIN. TYP. 1/8" GAP TYP. 3/8" MIN. TYP. DETAIL E NOTE: ALL BLOCKED AND UNBLOCKED DIAPHRAGMS (ROOF AND FLOOR) SHALL BE CONSTRUCTED AS FOLLOWS: 1. REVIEW THE PLAN NOTES AND DRAWINGS FOR ADDITIONAL REQUIREMENTS OF FLOOR AND ROOF CONSTRUCTIONS. 2. WOOD STRUCTURAL PANELS SHALL CONFORM TO THE REQUIREMENTS FOR THEIR TYPE IN DOC PS 1 OR DOC PS2. 3. WHERE DIAPHRAGMS ARE DESIGNATED AS BLOCKED, ALL JOINTS IN SHEATHING SHALL OCCUR OVER AND BE FASTENED TO COMMON FRAMING MEMBERS OR COMMON BLK'G. THE SIZE AND SPACING OF FASTENERS AT WOOD-FRAME DIAPHRAGM BOUNDARIES AND PANEL EDGES SHALL BE AS SPECIFIED ON THESE DWGS. 4. PANELS SHALL NOT BE LESS THAN 4' X 8' EXCEPT AT BOUNDARIES AND CHANGES IN FRAMING WHERE MIN. PANEL DIMENSION SHALL BE 24" UNLESS ALL EDGES OF THE UNDERSIZED PANELS ARE SUPPORTED BY AND FASTENED TO FRAMING MEMBERS OR BLK'G. INDIVIDUAL SHEET OF SHEATHING SHALL NOT BE LESS THAN 2'-0" IN THEIR LEAST PLAN DIMENSION NOR LESS THAN 8 SQ.FT. IN AREA. 5. FOR UNBLOCKED DIAPHRAGMS, THE BLK'G BTWN. SUPPORTING STRUCTURAL MEMBERS AT PANEL EDGES IS NOT REQD. 6. NAILS SHALL BE LOCATED AT LEAST 3/8" FROM THE EDGES OF PANELS.MAX. NAIL SPACING AT PANEL EDGES SHALL BE 6" ON CENTER. 7. NAILS ALONG INTERMEDIATE FRAMING MEMBERS AND BLK'G FOR PANELS SHALL BE THE SAME SIZE AS INSTALLED AT THE PANEL EDGES. 8. MAX. NAIL SPACING SHALL BE 6" ON CENTER WHEN SUPPORT SPACING OF 48" ON CENTER IS SPECIFIED AND 12" ON CENTER FOR CLOSER SUPPORT SPACINGS. 9. THE WIDTH OF THE NAILED FACE OF FRAMING MEMBERS AND BLK'G SHALL BE 2" NOMINAL OR GREATER AT ADJOINING PANEL EDGES EXCEPT THAT A 3" NOMINAL OR GREATER WIDTH AT ADJOINING PANEL EDGES AND STAGGERED NAILING AT ALL PANEL EDGES ARE REQD. WHERE: 9.1. NAIL SPACING OF 2-1/2" ON CENTER OR LESS AT ADJOINING PANEL EDGES IS SPECIFIED, OR 9.2. 10D COMMON NAILS HAVING PENETRATION IN-TO FRAMING MEMBERS AND BLK'G OF MORE THAN 1-1/2" ARE SPECIFIED AT 3" ON CENTER OR LESS AT ADJOINING PANEL EDGES. 10. SPECIFIED STRAPS OR HOLDOWN SYSTEM SHALL BE USED TO SPLICE THE WALL TOP PLATES, SILL/BOT PLATES, BEAMS OR OTHER DRAG ELEMENTS. SHEATHING SHALL NOT BE USED TO SPLICE THE PLATES OR BEAMS. 11. TONGUE-AND-GROOVE SHEATHING SHALL BE INSTALLED W/ THE TONGUES UP ON SLOPED OR PITCHED ROOFS W/ PATTERN FACES DOWN. 12. WHERE RAFTER OR JOIST. LAP SPLICE OCCURS AND PLYWOOD JOINT IS CONTINUES,SEE DETAIL B. BRIDGING/BLK'G IS REQD. AT 96" O.C.MAX. SEE DETAILS C AND D. 13. SHEATHING NAILS OR OTHER APPROVED SHEATHING CONNECTORS SHALL BE DRIVEN SUCH THAT THEIR HEAD OR CROWN IS FLUSH W/ THE SURFACE OF THE SHEATHING OVER-DRIVEN NAILS SHALL NOT BE PERMITTED AND SHALL BE DEEMED UNSATISFACTORY. 14. AT UNBLOCKED DIAPHRAGMS, NAIL SPACING AT DIAPHRAGM BOUNDARIES AND SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6” O.C.AND FIELD NAILING SHALL NOT BE SPACED MORE THAN 12”O.C. 15. AT BLOCKED DIAPHRAGMS,NAIL SPACING AT DIAPHRAGM BOUNDARIES AND AT ALL CONTINUES PANEL EDGES SHALL NOT BE MORE THAN 6 IN. NAIL SPACING AT ALL OTHER PANEL EDGES SHALL NOT BE MORE THAN 6 IN. CONT. PANEL JOINT IN BOTH DIRECTIONS SHALL NOT BE PERMITTED. FIELD NAILING SHALL NOT BE SPACED MORE THAN 12” O.C. STRAP DETAIL W SCALE:NTS. SHEATHING PER PLAN 2X RIM JST. BLK'G L L EDGE NAILING PER PLAN NOTE HEADER PER PLAN HORIZONTAL STRAP PER PLAN JACK PER PLAN SHEAR WALL PER PLAN 2X STUDS PER PLAN 16d @12" O.C. SHEATHING PER PLAN JST. PER PLANBLK'G L L HORIZONTAL STRAP PER PLAN POST PER PLAN SHEAR WALL PER PLAN 2X STUDS PER PLAN CONNECTION PER PLAN IF CONNECTION NOT MENTIONED IN PLAN SEE WALL SHEET ON 01/S1.24 KING PER PLAN CONNECTION PER PLAN BEAM PER PLAN 16d @12" O.C. SHEATHING PER PLAN JST. PER PLANBLK'G L L HORIZONTAL STRAP PER PLAN POST PER PLAN SHEAR WALL PER PLAN 2X STUDS PER PLAN CONNECTION PER PLAN BEAM PER PLAN 16d @12" O.C. A35 PER SHEARWALL SCHEDULE A35 PER SHEARWALL SCHEDULE A35 PER SHEARWALL SCHEDULE DBL. 2X TOP PLATE DBL. 2X TOP PLATE DETAIL A STRAP L (MIN. END LENGTH (IN.) INSTALLED IN EVERY HOLE) MIN. FASTENERS CAPACITY(lb) C16 11"(18) 0.148 x 2 1/2 1700 CS14 13"(24) 0.148 x 2 1/2 2390 CMSTC16 19"(48) 0.148 x 2 1 2 4610 CMST14 27"(58) 0.148 x 2 1/2 5770 CMST12 35"(76) 0.148 x 2 1/2 8320 DETAIL B DETAIL C 3 3'-0" 3'-0" SIMPSON CS14 STRAP UNO PER PLANTRUSS TOP CHORD OR ROOF RAFTER PER PLAN ROOF SHEATHING DRAG JACK TRUSS/ ROOF RAFTER W/ E.N. PER PLAN 2x BLK'G W/ E.N. SEE PLAN FOR LENGTH 3'-6" 3'-6" 2x ROOF RAFTER W/ E.N. SIMPSON CS14 STRAP UNO PER PLAN STUD OR POST PER PLAN ROOF SHEATHING ROOF JOISTS SIT ON WALL LINE OF E.N. W SCALE:NTS. 2 DRAG DETAIL ROOF SHEATHING DATE: P.M.: DRAWN BY: JOB NO.: 30211 Avenida de las Banderas, Suite 200, Rancho Santa Margarita, California, 92688 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D E SI GN B U I L D CNI UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT REV DATE REMARKS M.A. ISSUED FOR PERMIT12.17.20240 07.13.2025 20241149 ISSUED PER CITY PERMIT07.13.20251 S1.25 TYPICAL WOOD DETAILS 07/15/2025 EXP. 06-30-2026 W SCALE:NTS. 1 PLUMBING DETAIL HVAC CHASE (2) ADJACENT BAYS 3-16d FASTENERS EVERY 16" LOAD BEARING WALL W/ HVAC CHASE RPS28Z (NOTE 1) PSPN58Z (NOTE 3) PSPN516Z (NOTE 2) HVAC CHASE IN EXT. OR LOAD BRG. WALL RPS28 (NOTE 1) CTS218 (NOTE 9) PSPN516Z (NOTE 2) MSTC (NOTE 8) NS2 (NOTE 4) SS1.5 (NOTE 5) WATER OR VENT PIPE TO 2ND FLOOR ELECTRICAL WIRING HSS2- 3-SDS3 (NOTE 7)NS1 (NOTE 4) HSS2-SDS1.5 (NOTE 6) SUPPLY LINES NS1 (NOTE 4) NOTES: 1. RPS28 (16 GAUGE) TO REINFORCE TOP PLATE, AND RPS28Z (16 GAUGE ZMAXTM/) TO REINFORCE SILL PLATE. 2. PSPN516Z (16 GAUGE ZMAXTM/) AT TOP OR BOT PLATES 3. PSPN58Z (16 GAUGE ZMAXTM/) AT TOP OR BOT PLATES AND M1308.2 4. NS - NAIL STOPS TO PROTECT PIPING FROM DRYWALL NAILS OR SCREWS. 5. SS1.5 (16 GAUGE) STUD SHOES REINFORCE AND PROTECT PLUMBING IN 2X. AND M1308.2 AND 2308.5.10 6. HSS2-SDS1.5 (16 GAUGE) HEAVY STUD SHOES TO REINFORCE AND PROTECT SINGLE 2X STUDS WHERE PIPE IS LOCATED. USES (12) SDS 1/4" x 11/2" SCREWS (INCLUDED). 7. HSS2-3-SDS3 (16 GAUGE) HEAVY STUD SHOE FOR TRIPLE 2X STUD. USES (12) SDS 1/4" x 3" SCREWS (INCLUDED). AND M1308.2 AND 2308.5.10 8. MSTC (16 GAUGE) AT TOP PLATE 9. CTS218 (14 GAUGE) TO REINFORCE TOP-PLATE FOR BOTH COMPRESSION AND TENSION FORCES 4.1.4 W SCALE:NTS. 2 PSPN516Z MODEL NO.GA DIMENSIONS BOTTOM PLATE (12) 0.162" x 3 1/2" NAILS TOP PLATE (16) 0.162" x 3 1/2" NAILS (24) 0.162" x 3 1/2" NAILS ALLOWABLE LOAD (lb.) ALLOWABLE LOAD (lb.) ALLOWABLE LOAD (lb.) DF/SP SPF/HF DF/SP SPF/HF DF/SP SPF/HF W L (160)(160)(160)(160)(160)(160) PSPN516Z 16 5"16 5/16"1320 1145 1760 1530 2640 2290 NOTES: 1. TO MEET THE PRESCRIPTIVE IRC REQUIREMENTS 16d BOX NAILS (0.135" DIA x 31/2") MAY BE USED. 2. ALLOWABLE TENSION LOAD IS 0.75 OF TABLE LOADS WHEN INSTALLED W/ 16d BOX NAILS. 16 5/16" 5" SCALE:NTS. 3 PSPN516Z NAIL STOPPER (TOP OR BOT PLATE REPAIR PLUS PLUMBING LINE PROTECTOR) W SCALE:NTS. 4PSPN58Z NAIL STOPPER (PLUMBING LINE PROTECTOR)W NOTES: PSPN58Z (16 GAUGE ZMAXTM/) AT TOP OR BOT PLATES PSPN58Z PSPN58Z 8" 5" SCALE:NTS. 5 W 4 1/2" MAX. GAP APPLY CTS218 ON THE BOTH SIDES OF BOTH TOP PLATES AT SHEAR/BRACE WALL LINES, UNO SPECIFICALLY APPROVED BY STRUCTURAL ENGINEER IN WRITING. THE GC SHALL RFI THE FIELD CONDITIONS AS REQUIRED. NS NAIL STOPPER (PLUMBING AND ELECTRICAL LINE PROTECTOR) NOTES: NS - NAIL STOPS TO PROTECT PIPING FROM DRYWALL NAILS OR SCREWS. (3) NS1 <1 1/4" NS2 SUPPLY LINES NS NAIL STOPPER (PLUMBING AND ELECTRICAL LINE PROTECTOR) NS1 (NS2 SIMILAR) W L NS1 NOTES: 1. OPTIONAL NAILS : 8d = 0.131" DIA. x 31/2" LONG. MODEL NO.GA.DIMENSIONS W L NS1 14 11 2"3" NS2 11 2"6" SCALE:NTS. 8 W SS3 SS4.5 SCALE:NTS. 9 FOR NON-LOAD BEARING WALL COMPRESSION-TENSION STRAP (TOP PLATE REPAIR) W MODEL NO.GA.STUD SIZE FASTENERS (TOTAL) ALLOWABLE LOADS (lb.) DF/SP LUMBER COMPRESSION FLOOR (100)ROOF (125) SS1.5 16 2X (12) 0.148" x 11 2"500 500 SS2.5 3X (12) 0.148" x 11 2"730 740 SS3 (2) 2X (12) 0.148" x 3"730 830 SS4.5 (3) 2X (14) 0.148" x 3"840 840 3 1/4" 6" 2 1 / 2 " HSS2 HSS2-3 HSS-SDS STUD SHOE FOR LOAD BEARING WALL(NOTCHED STUD REINF. AND PLUMBING LINE PROTECTOR) MODEL NO.GA.STUD SIZE FASTENERS (TOTAL) ALLOWABLE LOADS (lb.) DF/SP LUMBER COMPRESSION TENSION FLOOR (100)ROOF (125) HSS2-SDS1.5 16 2X (12) 1 4" x 11 2" SDS 1165 1165 1025 HSS2-2-SDS3 2-2X (12) 1 4" x 3" SDS 1165 1165 1025 HSS2-3-SDS3 3-2X (12) 1 4" x 3" SDS 990 990 960 HSS4-SDS3 4X (12) 1 4" x 3" SDS 1205 1205 1025 NOTES: 1. INSTALLS OVER PIPE UP TO 23/8" OUTSIDE DIAMETER. 2. SDS SCREWS PROVIDED. 3. ROOF LOADS ARE 125% OF FLOOR LOADS UNLESS LIMITED BY OTHER CRITERIA. FLOOR LOADS MAY BE ADJUSTED FOR LOAD DURATIONS ACCORDING TO THE CODE, PROVIDED THEY DO NOT EXCEED ROOF LOADS. 3 1/4" 7 1 / 8 " 2 3 / 4 " CODES: ICC-ES ESR-2608; FLORIDA FL10864 SCALE:NTS. SS/HSS-SDS STUD SHOE FOR LOAD BEARING WALL (CLR. REQUIREMENTS) W NOTES: 1. DISTANCE BTWN. CENTER LINE OF SUPPLY LINE AND CENTER LINE OF VENT PIPE MUST BE A MIN. OF 67/8" TO PROVIDE ADEQUATE SPACE FOR THE HSS AND NS2. NS2 SUPPLY LINE VENT PIPE HSS 6 7 / 8 " M I N . 1/2" SCALE:NTS. MSTC (HVAC REPAIRS - AT NON-LOAD BEARING OR SHEAR/BRACE WALL LINES TOP PLATE REPAIR (CONSECUTIVE BAYS)) W NOTES: 1. MSTC HAS COUNTERSUNK NAIL SLOTS FOR A LOWER PROFILE. 2. USED WHEN THE TOP PLATES ON TWO CONSECUTIVE BAYS HAVE BEEN REMOVED. 3. TO MEET THE PRESCRIPTIVE IRC REQUIREMENTS, 16d BOX (0.135" DIA. x 31/2" LONG) MAY BE USED. ALLOWABLE TENSION LOAD IS 0.88 OF TABLE LOADS WHEN INSTALLED W/ 16d BOX NAILS. 4. NAILS SHOULD BE EQUALLY DISTRIBUTED TO BOTH TOP PLATES. CODES: ICC-ES ESR-2105 W/ LA SUPPLEMENT; HVAC CHASE (2) ADJACENT BAYS MSTC52 7 10 PSPN516Z (16 GAUGE ZMAXTM) NAIL STOPPER (TOP OR BOT PLATE REPAIR PLUS PLUMBING LINE PROTECTOR)HSS-SDS STUD SHOE FOR LOAD BEARING WALL (NOTCHED STUD REINF. AND PLUMBING LINE PROTECTOR) SS STUD SHOE FOR NON-LOAD BEARING WALL SHOE (NOTCHED STUD REINF. AND PLUMBING LINE PROTECTOR) BORED HOLES D/3 2 x 6 = 1 13/16" 2 x 8 = 2 7/16" 2 x 10 = 3 1/16" 2 x 12 = 3 3/4" CUTTING AND NOTCHING *40% ALLOWED NON-BRG. PARTITIONS BRG. WALLS AND PARTITIONS ALLOWABLE BORED HOLE MAX. DIA. 40% OF STUD DEPTH THE EDGE OF BORE HOLE SHALL NOT BE CLOSER THAN 5/8'' TO THE EDGE OF THE STUD IN EA. DIRECTION ALLOWABLE CUT OR NOTCH DEPTH IS 25% OF STUD WIDTH NO BORED HOLES LOCATED AT THE SAME SECTION OF THE STUD WHERE CUT OR NOTCH BORDER HOLE 1 7/16" MAX. IN BRG. WALL 2 3/16" MAN IN NON-BRG. WALL STUD WALL PER PLAN UNO PER SHEAR WALL SCHED. BORED HOLES SHALL NOT BE LOCATED AT THE SAME SECTION OF STUD AS A CUT OR NOTCH THE EDGE OF BORE HOLE SHALL NOT BE CLOSER THAN 5/8'' TO THE EDGE OF THE STUD IN EA. DIRECTION ALLOWABLE CUT OR NOTCH DEPTH IN 40% OF WIDTH NON-BRG. PARTITIONS WHERE HOLES ARE OVER 1/3 PLATE WIDTH USE G.I. 1 1/2"X16 GA X12" LONG EA. SIDE W/(5) 8d EA. END ALLOWABLE BORED HOLE 60% OF STUD WIDTH ONLY WHERE EA. BORED STUD IS DOUBLED PROVIDED NOT MORE THAN TWO SUCH SUCCESSIVE STUDS ARE BORED STUD NOTCH 2 x 4 STUD= 1 7/16" MAX. 2 x 6 STUD= 2 3/16" MAX. 2 x 4 STUD= 1 4/16" MAX. 2 x 6 STUD= 2 3/16" MAX. BORED HOLE 5/8" MIN. SIMPSON HSS2-2-SDS3 GALVANIZED W SECTION A WHERE FRAMING MEMBER OCCURS ABV. WITHIN PENETRATED STUD SPACE ADD SUPPORT STUD BELOW SECTION B5/ 8 " M I N . EA . S I D E DRILL NEAT HOLE PER SCHEDULE A B TOP PLATES 2" MIN. FROM TOP&BOT OF JOIST PIPE OF CONDUIT NOTCH GREATER THAN 50% OF THE PLATE WIDTH 7/8" MAX.@BEARING WALL 1 13/16"@NON-BEARING WALL *40% ALLOWED ANY NON-BRG. WALL BORED HOLES *40% ALLOWED BRG. WALL BORED HOLE (2)-2 x 4 STUD BORED HOLE<2" BORED HOLES *25% ALLOWED EXT. WALLS AND BRG. PARTITION STUD NOTCH 2 x 4 STUD= 1 7/16" MAX. 2 x 6 STUD= 2 3/8" MAX. 2 x 4 STUD= 1 7/8" MAX. 2 x 6 STUD= 3 5/16" MAX. BORED HOLE 5/8" MIN. SIMPSON HSS2-3-SDS3 GALVANIZED *60% ALLOWED ANY NON-BRG. WALL OR EA. BORED STUD DOUBLED BORED HOLE NOT PERMITTED IN MORE THAN TWO SUCCESSIVE DOUBLED STUDS *60% ALLOWED BRG. WALL BORED HOLE (3)-2 x 4 STUD BORED HOLE<2 1/2" NOTES: 1. ALL NOTCHES SHOULD BE SEALED WITH A WATER-REPELLENT SEALER, IMMEDIATELY AFTER CUTTING 2. ROUND THE SQUARE CORNER OF THE NOTCH TO A MIN. 1/2" RADIUS. 3. BRG. AND NON-BRG. WALLS: a. NOTCHES AND HOLES ARE ONLY PERMITTED IN OUTER 1/3 OF SPAN LENGTH OF STUD b. BORED HOLES SHALL NOT BE LOCATED IN THE SAME CROSS SECTION OF CUT OR NOTCH IN STUD 4. NON-BRG. WALLS: IF HOLE IS BTWN. 40% AND 60% OF STUD DEPTH, THEN STUD MUST BE DOUBLED AND MORE THAN TWO SUCCESSIVE STUDS ARE DOUBLED AND SO BORED. D (DEPTH) D/3 MAX. CUTTING, NOTCHING AND BORING AT STUD WALL6 W SCALE:NTS. (2)RPS 22 W/ 8-16d NAILS EA. SIDE 5" MAX. (2)RPS 22 W/ 8-16d NAILS EA. SIDE (2)RPS 22 W/ 8-16d NAILS EA. SIDE MODEL NO.GA.DIMENSIONS FASTENERS (TOTAL) ALLOWABLE TENSION LOADS (lb.) DF/SP ALLOWABLE TENSION LOADS (lb.) SPF/HF MSTC52 16 W L NAILS (160)(160) 3"52 1 4"(16) 0.162" x 31 2"1535 1330 DATE: P.M.: DRAWN BY: JOB NO.: 30211 Avenida de las Banderas, Suite 200, Rancho Santa Margarita, California, 92688 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D E SI GN B U I L D CNI UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT REV DATE REMARKS M.A. ISSUED FOR PERMIT12.17.20240 07.13.2025 20241149 ISSUED PER CITY PERMIT07.13.20251 S1.26 TYPICAL WOOD DETAILS 07/15/2025 EXP. 06-30-2026 LANDING FOUNDATION PLAN SCHEDULE SYMBOL DESCRIPTIONS SCALE: 1/4"=1'-0"FOUNDATION PLAN1 INDICATES SHEARWALL TYPE FOR SHEARWALL SCHEDULE SEE 1/S1.21 INDICATES MINIMUM LENGTH OF SHEARWALL SWXX (#'-#") INDICATES HOLDOWN TYPE X INDICATES STEEL SECTION POST MARK, ALL POSTS ARE STEEL SECTION UNO ON PLANS INDICATES WOOD POST MARK, SEE POST SCHEDULE C# HDU X # S#.##INDICATES SECTION INDICATES SHEET NUMBER INDICATES DETAIL NUMBER ON THE SHEET INDICATES TYP. 12" WIDE FOUNDATION UNO ON PLAN INDICATES HANGER S#.## # INDICATES CALLOUT #INDICATES REVISION ON DRAWINGS INDICATES VIEW# S#.## INDICATES LOAD BEARING WALL BW SOG REQUIREMENT NOTES FOUNDATION PLAN NOTES SW1 (13'-10") SW1 (2'-8") WS P (1 7 ' - 3 " ) SW 1 (1 3 ' - 0 " ) WS P (2 5 ' - 9 " ) 12" 12 " 12" 12 " 12" 12 " 12" 12" SEE NOTE A SW1 (8'-2")16 " 1 S1.01 TYP 5 S1.01 TYP 1 S1.01 TYP S1.01 2 REVIEW THE PLAN NOTES AND PERFORM FIELD CONDITION ASSESSMENT AND VERIFICATION PRIOR TO COMMENCING THE WORK. 1. SOIL SUBGRADE REQUIREMENTS, ELEVATION AND SLOPING OF FOUNDATIONS AND SOG, AND CONSTRUCTION REQUIREMENTS ARE NOT PART OF THIS SCOPE OF WORK OR THE LIABILITY OF THE STRUCTURAL ENGINEER. 2. IF GEOTECHNICAL REPORT OR CIVIL DWGS. ARE AVAILABLE, CONTRACTOR SHALL REVIEW AND FOLLOW THE GEOTECHNICAL REPORT AND CIVIL DWG. FOR THE CONSTRUCTION OF SOIL SUBGRADE AND SOG. 3. IN THE ABSENCE OF GEOTECHNICAL REPORT, OR CIVIL REPORT AND DWGS. THE DETAILS SHOWN ON THESE DWGS. MAY BE CONSIDERED BY THE OWNER/GC ON THEIR OWN RISK. STRUCTURAL ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY DAMAGES THAT MAY OCCUR DUE TO USING THESE RECOMMENDATIONS.THESE ARE GENERAL RECOMMENDATIONS FOR THE CONSTRUCTION OF SOIL SUBGRADE. THESE DETAILS DO NOT CONSIDER THE ACTUAL FIELD CONDITIONS. 3.1. SOG AND FOUNDATIONS SHALL BE CONTINUOUSLY SUPPORTED ON UNDISTURBED OR ENGINEERED FILL SOIL. 3.2. THE AREA WITHIN THE SOG AND FOUNDATION WALLS SHALL HAVE ALL VEGETATION, TOP SOIL AND FOREIGN MATERIAL REMOVED. 3.3. FILL MATERIAL SHALL BE FREE OF VEGETATION AND FOREIGN MATERIAL. THE FILL SHALL BE COMPACTED TO ENSURE UNIFORM SUPPORT OF THE SOG, FOUNDATION, AND THE FILL DEPTHS SHALL NOT EXCEED 24 IN FOR CLEAN SAND OR GRAVEL AND 8 IN FOR EARTH. 3.4. AT SOG AREA, REINFORCING STEEL SHALL BE SUPPORTED TO REMAIN IN PLACE FROM THE CENTER TO MIDDLE FOURTH OF THE SLAB FOR THE DURATION OF THE CONC. PLACEMENT. 3.5. SCARIFY TOP 12" OR RECOMPACT 4' OVEREXCAVATION PRIOR TO TRENCHING FOR THE UTILITY AND/OR FOUNDATION. 90% COMPACTION REPORT IS REQUIRED AT THE OF FOUNDATION INSPECTION. DAMP PROOFING, BASE COURSE AND PRE-SATURATION ARE REQUIRE. 3.6. PROVIDE 5" SLAB ON GRADE REINFORCED WITH #4 AT 18" ON CENTERS EACH WAY OVER 4" BASE OF 1 2" OR LARGER CLEAN AGGREGATE WITH 10 MIL VAPOR RETARDER IN DIRECT CONTACT WITH CONCRETE. SLAB SHAL BE TIED-IN TO CONTINUOUS 12" WIDE x 24" (MINIMUM EMBEDMENT INTO FIRM SOIL) FOUNDATION. 4. PROVIDE CONTROL JOINTS AT CL. OF CONC. OR STEEL COLUMNS IF NO CONSTRUCTION JOINTS OCCUR. 5. CONTRACTOR TO SUBMIT A JOINTING PLAN TO ARCHITECT FOR REVIEW. 6. THE TOP SURFACE OF FOUNDATIONS SHALL BE LEVEL ,UNO ON ARCH. DWG. 7. THE BOTTOM SURFACE OF FOUNDATION AND SOG SHALL NOT HAVE A SLOPE EXCEEDING ONE UNIT VER. IN 12 UNITS HOR. 8. UNO ON PLANS OR TYPICAL DETAILS, NO HOR. CONSTRUCTION SHALL BE PERMITTED IN THE FOUNDATIONS. ALL OTHER CONSTRUCTION JOINTS SHALL BE SUBMITTED TO SEOR AND ARCH FOR REVIEW. POST SCHEDULE UNO ON PLAN MARK POST SIZE C44 4x4 C44 W/B C 4 0 C44 W/B C 4 0 C44 W/B C 4 0 C44 HDU 2HDU 2 C44 C44 HDU 2 HDU 2 HDU 2 C44 C44 W/B C 4 0 C44 W/B C 4 0 C44 W/B C 4 0 C44 W/B C 4 0 C44 W/B C 4 0 C44 W/B C 4 0 C44 W/B C 4 0 C44 W/B C 4 0 C44 W/B C 4 0 C44 W/B C 4 0 C44 C44 W/B C 4 0 HDU 2C44 C44 HDU 2 HDU 2 C44HDU 2 HDU 2 C44 C44HDU 2 12 " 1 A B C D 2 3 4 NOTE A: 5" SOG W/#4@18"O.C. EACH WAY. SEE SOG REQUIREMENT NOTES FOR CAPILLARY BREAK REQUIREMENTS. 12 " LANDING SEE DETAIL 9/S1.01 C44 C44 W/B C 4 0 1 . T HES E D R A W I N G AR E BASE D O N T HE B EST A VAI L AB L E SO U R C E S AND D O N O T A DD R ES S T HE F IELD CONDITIONS. THE CONTR ACTOR SHALL V ERIFY ALL FIELD CONDITIONS AND ALL EXISTING STRUCTURAL E L E M E N T S S P E C I F I E D A S V E R I F I E D I N F I E L D (V .I .F .) P R I O R T O C O M M E N C I N G T H E W O R K . A N Y DISCREPANCIES BETWEEN THESE DRAWINGS AND FIELD CONDITIONS SHALL BE REPORTED TO THE AEOR AND SEO R . N O W OR K SHAL L BE P E RFOR MED IN T HE AFF E CT ED A REAS UNTIL TH E DIS CR EP ANC I E S AR E RESOLVED. 2. NO CUTTING, DRILLING, DEMOLITION OR DESTRUCTIVE WORK ON CONCRETE OR WOOD ELEMENTS SHALL BE PERMITTED UNLESS ALL REINFORCING STEEL INCLUDING PT TENDONS, BEARING WALLS, SHEAR WALLS, BEAMS,AND DIRECTIONS OF JOISTS AND RAFTERS THAT WILL BE AFFECTED ARE POSITIVELY IDENTIFIED. 3 . CO NT R A C T O R I S S O L E L Y R E S P O NS IB L E F O R P R O T E C T I O N O F A L L ST R U C T U R AL, N O N S T R U C T UR A L , ARCHITECTURAL, FINISHING, ELECTRICAL AND MECHANICAL COMPONENTS WHICH ARE NOT DESIGNATED FOR DEMOLITION OR NEW CONSTRUCTION. ANY DAMAGES CAUSED BY THE CONTRACTOR OR SUBCONTRACTORS SHALL BE REPAIRED BY THE CONTRACTOR AT NO COSTS TO THE ENGINEERS OR OWNER. 4. STRUCTURAL DRAWINGS ARE NOT STAND-ALONE DOCUMENTS AND ARE INTENDED TO BE USED IN CONJUNCTION WITH CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND DRAWINGS FROM OTHER DISCIPLINES. THE CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS INTO THE SHOP DRAWINGS AND FIELD WORK. 5. ALL ELEVATIONS, SLOPES, DRAINAGE, DIMENSIONS OF OPENINGS, PENETRATIONS, DEPRESSIONS, AND LAYOUT AND GEOMETRY OF NONSTRUCTURAL ELEMENT SUCH AS BUT NOT LIMITED TO PARTITION, WINDOWS, PLUMBING, ARE NOT INCLUDED IN THE STRUCTURAL ENGINEERING SCOPE OF WORK AND SHALL NOT BE THE RESPONSIBILITY OF THE STRUCTURAL ENGINEER. REFER TO THE DRAWINGS FROM OTHER PROFESSIONS FOR THE INFORMATION MENTIONED ABOVE. 6. FOR CONSTRUCTION NOTES AND TYPICAL SYMBOLS DESCRIPTIONS, SEE S0 SERIES SHEETS. 7. FOR TYPICAL DETAILS, SEE S1 SERIES SHEETS. DETAILS AND SCHEDULES INDICATED AS 'TYPICAL' MAY NOT BE SPECIFICALLY REFERENCED ON DRAWINGS. DETERMINE WHERE EACH TYPICAL DETAIL OR SCHEDULE APPLIES BEFORE PROCEEDING WITH WORK. 8. SEE ARCH./CIVIL DWGS. FOR CONCRETE SLAB ELEVATIONS, DEPRESSIONS, SLOPES, OPENINGS, CURBS, DRAINS, TRENCHES, SLAB EDGE LOCATIONS, ETC., AND FOR WALL OVERALL DIMENSIONS, LOCATIONS OF OPENINGS, ETC., NOT INDICATED ON STRUCTURAL DWGS. 9. HOLD-DOWNS& ANCHORS HARDWARE MUST BE SECURED IN PLACE PRIOR TO CALLING FOR FOUNDATION INSPECTION. WET SETTING ANCHORS IS PROHIBITED. 10. APPROVED PLATE WASHERS SHALL BE USED FOR HOLD-DOWN CONNECTOR BOLTS INTO WOOD FRAMING. HOLD-DOWNS SHALL BE FINGER TIGHT AND 1/2 WRENCH TURN JUST PRIOR TO COVERING WALL FRAMING. 11. STANDING WATER SHALL BE REMOVED FROM THE FOUNDATION EXCAVATIONS PRIOR TO THE CONCRETE PLACING. 12. UNO IN ARCH./CIVIL DWGS. SURFACE OUTSIDE THE HOUSE NEEDS TO HAVE 5% SLOPE (UNPAVED SURFACE) & 2% SLOPE (PAVED SURFACE) AWAY FROM THE STRUCTURE. 13. ANCHOR BOLTS IN CONTACT WITH PRESSURE TREATED SILL PLATE SHALL BE OF HOT-DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. 14. MINIMUM EDGE DISTANCE FOR ANCHOR BOLTS SHALL BE 1-3/4". ALL ANCHOR BOLTS SHALL INCLUDE A MINIMUM 0.229"X3"X3" STEEL PLATE WASHER. THE HOLE IN THE PLATE WASHER SHALL BE PERMITTED TO BE DIAGONALLY SLOTTED WITH A WIDTH OF UP TO 3/16" LARGER THAN THE BOLT DIAMETER AND A SLOT LENGTH NOT TO EXCEED 1-3/4", PROVIDED A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND THE NUT. THE PLATE WASHER SHALL EXTEND TO WITHIN 1/2" OF THE EDGE OF THE BOTTOM PLATE ON THE SIDE(S) FOR SHEATHING WITH SHEAR DESIGN VALUES EXCEEDING 400PLF. 15. THE FOUNDATION PLAN SHOWS THE GENERAL LAYOUT OF THE FOUNDATION. FOR LOCALIZED SIZE CHANGES AT THE HOLD-DOWNS, REFER TO TYPICAL DETAILS. AT ALL HOLD-DOWN LOCATIONS, FOUNDATION SHALL BE CONSTRUCTED WITH THE DIMENSIONS SPECIFIED IN TABLE FOR HOLD-DOWN ANCHOR SCHEDULE SEE SHEET S1.01. 16. ALL WOOD MEMBERS IN CONTACT WITH MASONRY AND CONCRETE SHALL BE PRESSURE-TREATED AND CONFORM TO THE REQUIREMENT OF "AWPA U1" FOR CATEGORY UC4A OR BETTER. 17. WOOD AND WOOD BASED MATERIALS USED RAISED FLOOR SYSTEMS INCLUDING JOISTS AND BEAMS SHALL CONFORM TO THE REQUIREMENTS OF "AWPA U1" FOR CATEGORY UC3B OR HIGHER. 18. NO HORIZONTAL COLD JOINTS OTHER THAN THE LOCATIONS SHOWN ON THESE DRAWINGS SHALL BE PERMITTED IN FOUNDATION CONSTRUCTION. ALL CONSTRUCTION JOINTS SHALL BE SUBMITTED TO SEOR FOR REVIEW. 19. BEARING WALLS SHALL BE SHEATHED ON NOT LESS THAN ONE SIDE OR BRIDGING SHALL BE INSTALLED NOT GREATER THAN 4 FEET APART MEASURED VERTICALLY FROM EITHER END OF THE STUD. 2x BLKG SHALL BE PROVIDED AT PLYWD JOINTS FOR ALL WALLS. 20. SPECIAL SOIL CONDITIONS AND PROPERTIES SUCH AS LIQUEFACTION ZONES; ADJACENT TO OR WITHIN AREAS PRONE TO LANDSLIDE, SLOPED LOTS GREATER THAN 1 UNIT VERTICAL UNITS HORIZONTAL ARE NOT INCLUDED IN THIS SCOPE OF WORKS AND NOT CONSIDERED FOR FOUNDATION DESIGN. OWNER SHALL HIRE A SOIL ENGINEER TO VERIFY THESE CONDITIONS AND THEIR EFFECTS ON STRUCTURAL ELEMENTS. 21. CONSTRUCTION BELOW THE RAISED FLOOR AND AT CRAWL SPACE INCLUDING LUMBERS AND TIMBERS SHALL BE GRADE 1 OR BETTER , JOISTS & BEAM THAT ARE AT LEAST 18" ABOVE GROUND SHALL BE CATEGORY 3B OR HIGHER AND POSTS, SILL PLATES AND BEAMS AND JOISTS LESS THAN 18" ABOVE THE GROUND SHALL BE CATEGORY 4A OR HIGHER AS SPECIFIED BY AWPA STANDARD U1. 22. ALL CRIPPLE WALLS SHALL BE BRACED. 23. ALL TOP AND BOTTOM CONTINUAL/ LONGITUDINAL BARS IN STRIP FOUNDATIONS SHALL HAVE STANDARD HOOKS AT THE ENDS. 24. ALL TOP AND BOTTOM DISCONTINUED/ LOCAL BARS ( IN BOTH DIRECTIONS ) AT THE PAD/ ISOLATED FOUNDATIONS SHALL HAVE STANDARD HOOKS AT THE ENDS. 25. ALL SOG BARS SHALL HAVE STANDARD HOOKS AT THE ENDS. 26. FOR DRAINAGE LAYOUT AND REQUIREMENTS, SEE ARCHITECTURAL/CIVIL DRAWINGS. DRAINAGE IS NOT INCLUDED IN STRUCTURAL ENGINEER'S SCOPE OF WORK. 27. WHERE THE STEEL COLUMNS ARE EXPOSED TO WEATHER, BASE PLATES AND COLUMNS UP TO 12" ABOVE THE CONCRETE SLAB SHALL BE COATED WITH MIN. 2 COATS OF MACROPOXY 646. 28. ALL PERMANENT STEELS IN CONTACT WITH WEATHER SHALL BE PROTECTED FOR CORROSION. 29.ALL HANGERS ,COLUMN CAPS ,AND COLUMN BASES ARE MINIMUM REQUIREMENTS ,PRIOR TO ORDER ALL OF THEM SHALL BE CHECKED BY THE CONTRACTOR / FRAMER ANY DISCREPANCY SHALL BE REPORTED TO SEOR. 30. FOR ALL BASE PLATES AND STEELS THAT ARE OUTSIDE OR UNDER GROUND, APPLY MIN. 2 COATS OF MACROPOXY 646 WITH MINIMUM 8 MILS THICKNESS. 31. THE LOCATION, DIMENSIONS, AND SPECIFIC REQUIREMENTS FOR MECHANICAL EQUIPMENT PADS, INCLUDING HEAT PUMP UNITS AND CONDENSERS, SHALL BE COORDINATED BY THE ARCHITECT WITH THE MECHANICAL ENGINEER, EQUIPMENT MANUFACTURER, AND OTHER RELEVANT DISCIPLINES. FINAL PAD DIMENSIONS, CLEARANCES, ANCHORAGE REQUIREMENTS, AND EQUIPMENT LOADS SHALL BE PROVIDED BY THE MECHANICAL ENGINEER AND/OR MANUFACTURER. 32. THE STRUCTURAL ENGINEER OF RECORD (SEOR) SHALL PROVIDE THE STRUCTURAL DESIGN OF THE PAD (E.G., THICKNESS, REINFORCEMENT) BASED SOLELY ON THE MECHANICAL LOADING AND LOCATION INFORMATION FURNISHED BY OTHERS. THE SEOR ASSUMES NO RESPONSIBILITY FOR DETERMINING EQUIPMENT LOCATION, UTILITY COORDINATION, ACCESSIBILITY, SERVICE CLEARANCE, VIBRATION ISOLATION, OR CONFORMANCE WITH MECHANICAL/ELECTRICAL CODES. 33. ANY CHANGE IN EQUIPMENT WEIGHT, CONFIGURATION, OR LAYOUT SHALL BE COMMUNICATED TO THE SEOR FOR VERIFICATION OF STRUCTURAL ADEQUACY PRIOR TO CONSTRUCTION. C44HDU 2 MI N . 3 ' - 0 " UN O O N H D U D E T A I L FOUNDATION WIDENING AT HOLD-DOWNS(TYP.) SEE HDU DETAIL HDU 2 C44 SW1 (8'-6") C44 W/B C 4 0 C44 W/B C 4 0 1 DATE: P.M.: DRAWN BY: JOB NO.: 30211 Avenida de las Banderas, Suite 200, Rancho Santa Margarita, California, 92688 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D E SI GN B U I L D CNI UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT REV DATE REMARKS M.A. ISSUED FOR PERMIT12.17.20240 07.13.2025 20241149 ISSUED PER CITY COMMENT07.13.20251 S2.01 FOUNDATION PLAN 07/15/2025 EXP. 06-30-2026 LANDING STRUCTURAL PLAN SCHEDULE STRUCTURAL PLAN NOTES SCALE: 1/4"=1'-0"CEILING PLAN1 SYMBOL DESCRIPTIONS HDR-2 HDR-1 CA. W/B C 4 0CA. W/B C 4 0 HDR-1 HD R - 1 C44 W/B C 4 C44 C44 W/4 - A 3 4 HDR-2HDR-2 HDR-1 CJ-1 C44 CJ-1 CJ-1 HD R - 1 CA. W/B C 4 0 HDR-1 CJ-1 4x 1 0 ( U P - S T A N D B E A M ) 4x 1 0 ( U P - S T A N D B E A M ) 4x8 (UP-STAND BEAM) CJ-1 CJ-1 DBL. 2x6 W/ LUS26-2 SW1 (13'-10") SW1 (8'-2") SW1 (2'-8") C44 HDU 2 HDU 2 WS P (1 7 ' - 3 " ) WS P (2 5 ' - 9 " ) SW 1 (1 3 ' - 0 " ) S1.23 4 CA. W/B C 4 0 TYP LUS410 HHUS46 HHUS46 6 S1.21 TYP 7 S1.22 TYP 3 S1.23 1 S4.01 TYP 3 S4.01 C44 S1.23 1 TYP REVIEW THE PLAN NOTES AND PERFORM FIELD CONDITION ASSESSMENT AND VERIFICATION PRIOR TO COMMENCING THE WORK. HD R HDR HDR C44 C44 C44 CJ-1 CJ-1 C44HDU 2 C44 HDU 2 CJ-1 C44 HDU 2 C44 CJ-1 C44HDU 2 HDU 2 C44 HDU 2 C44HDU 2 HEADER SCHEDULE UNO ON PLAN MARK HEADER SIZE JACK STUD SIZE KING STUD SIZE HANGER HDR-1 4x6 2x4 2x4 N/A HDR-2 4x8 2x4 2x4 N/A POST SCHEDULE UNO ON PLAN MARK POST SIZE C44 4x4 JOIST & HANGER SCHEDULE UNO ON PLAN MARK JOIST SIZE HANGER CJ-1 2x6 @16" O.C.LU26 STUD WALL SCHEDULE UNO ON PLAN/SHEAR WALL SCHED. MAX. HEIGHT INT. WALL EXT. WALL 8'-0"2x4 @16" O.C.2x4 @16" O.C. C44 W/4 - A 3 4 C44HDU 2 DBL.2x6 W/LUS26-2 SEE 2/S1.22 6 S1.22 1 A B C D 2 3 4 CJ-1 HDR-1 C44 W/4 - A 3 4 MST48 MST48 MST48 4x8 MST48 C44 W/B C 4 MST48 1 S4.01 DBL. 2x6 W/ LUS26-2 HDU 2 4x 1 0 ( U P - S T A N D B E A M ) SW1 (8'-6") C44 HD R - 1 C44 W/B C 4 0 ALL WOOD MEMBERS (I.E. PLYWOOD, LUMBER, TIMBER,NAILERS, ETC.) SHALL BE CLASSIFIED FOR EXTERIOR GRADE OR PRESSURE TREATED 3 S1.23 C44 W/B C 4C44 W/B C 4 C44 W/B C 4 HTS30HTS30 2 S4.01 DBL.2x6 W/LUS26-2 SEE 2/S1.22 DB L . 2 x 6 CJ-1 4x 1 0 ( U P - S T A N D B E A M ) C44 HDU 2 C44 W/4 - A 3 4 CJ-1 HD R HDU 2 C44 CA. W/B C 4 0 4x 1 0 C44 W/4 - A 3 4 HH4 CA. W/B C 4 0 1. TH E S E DR A WING AR E BA S ED O N T HE BEST A VAILA B LE SO UR CES A N D DO N OT A DD RE S S TH E FI E LD CONDITIONS. THE CONTRACTOR SHALL VERIFY ALL FIELD CONDITIONS AND ALL EXISTING STR UCTURAL E L E M E N T S S P E C I F I E D A S V E R I F I E D I N F I E L D (V .I .F .) P R I O R T O C O M M E N C I N G T H E W O R K . A N Y DISCREPANCIES BETWEEN THESE DRAWINGS AND FIELD CONDITIONS SHALL BE REPORTED TO THE AEOR AND SEOR. NO WOR K SHALL BE PER FOR MED IN THE A FFECTED AR EAS UNT I L THE DISCREPAN CIES AR E RESOLVED. 2. NO CUTTING, DRILLING, DEMOLITION OR DESTRUCTIVE WORK ON CONCRETE OR WOOD ELEMENTS SHALL BE PERMITTED UNLESS ALL REINFORCING STEEL INCLUDING PT TENDONS, BEARING WALLS, SHEAR WALLS, BEAMS,AND DIRECTIONS OF JOISTS AND RAFTERS THAT WILL BE AFFECTED ARE POSITIVELY IDENTIFIED. 3. C O N T R A CTO R I S S OLE LY R E S P ON S I BLE FO R P R O T EC T IO N O F ALL STR UC T U R A L , N ONST R UCT U R A L , ARCHITECTURAL, FINISHING, ELECTRICAL AND MECHANICAL COMPONENTS WHICH ARE NOT DESIGNATED FOR DEMOLITION OR NEW CONSTRUCTION. ANY DAMAGES CAUSED BY THE CONTRACTOR OR SUBCONTRACTORS SHALL BE REPAIRED BY THE CONTRACTOR AT NO COSTS TO THE ENGINEERS OR OWNER. 4. STRUCTURAL DRAWINGS ARE NOT STAND-ALONE DOCUMENTS AND ARE INTENDED TO BE USED IN CONJUNCTION WITH CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND DRAWINGS FROM OTHER DISCIPLINES. THE CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS INTO THE SHOP DRAWINGS AND FIELD WORK. 5. ALL ELEVATIONS, SLOPES, DRAINAGE, DIMENSIONS OF OPENINGS, PENETRATIONS, DEPRESSIONS, AND LAYOUT AND GEOMETRY OF NONSTRUCTURAL ELEMENT SUCH AS BUT NOT LIMITED TO PARTITION, WINDOWS, PLUMBING, ARE NOT INCLUDED IN THE STRUCTURAL ENGINEERING SCOPE OF WORK AND SHALL NOT BE THE RESPONSIBILITY OF THE STRUCTURAL ENGINEER. REFER TO THE DRAWINGS FROM OTHER PROFESSIONS FOR THE INFORMATION MENTIONED ABOVE. 6. REVIEW ALL NOTES PROVIDED IN FRAMING LUMBER AND ENGINEERED WOOD PRODUCT SECTION FOR GENERAL REQUIREMENTS AND CONFORMANCE OF STRUCTURAL WOOD. 7. FOR TYPICAL DETAILS SEE S1 SERIES SHEETS. 8. ROOF SHEATHING OVER ROOF RAFTER/JOISTS NOT SPACED MORE THAN 16" O.C. SHALL BE 15/32" OR 1/2" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, 32/16 ,EXTERIOR GRADE AND WITH EXTERIOR GLUE, (EXPOSURE1 OR EXTERIOR), SQUARE EDGE (OR TONGUE-AND-GROOVE). NAILS SHALL BE 8d WITH MINIMUM FASTENER PENETRATION IN FRAMING WOOD FOR 1-3/8 IN. NAIL SPACING AT INTERMEDIATE FRAMING (FIELD NAILING) SHALL NOT BE MORE THAN 12 IN. NAIL SPACING AT BOUNDARIES AND AT SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6 IN. IF OSB PANELS ARE USED, PANELS SHALL BE MOISTURE PROTECTED DURING THE CONSTRUCTION. 9. ROOF SHEATHING OVER RAFTERS/JOISTS OR TRUSSES SPACED AT 24" O.C. SHALL BE 19/32" OR 5/8" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, 40/20 ,EXTERIOR GRADE AND WITH EXTERIOR GLUE, (EXPOSURE1 OR EXTERIOR), SQUARE EDGE (OR TONGUE-AND-GROOVE) IF OSB PANELS ARE USED, PANELS SHALL BE MOISTURE PROTECTED DURING THE CONSTRUCTION.THE ROOF SHEATHING TO BE APPROVED BY THE BUILDING INSPECTOR BEFORE APPLICATION OF ROOFING. 10. FLOOR SHEATHING SHALL BE 23/32" OR 3/4" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, 48/24 WITH EXTERIOR GLUE, (EXPOSURE 1 OR EXTERIOR), SQUAERE EDGE (OR TONGUE-AND-GROOVE ).NAILS SHALL BE 10d WITH MINIMUM FASTENER PENETRATION IN FRAMING WOOD FOR 1-3/8 IN. NAIL SPACING AT INTERMEDIATE FRAMING (FIELD NAILING) SHALL NOT BE MORE THAN 12 IN. NAIL SPACING AT BOUNDARIES AND AT SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6 IN, U.N.O. ON PLANS. 11. BALCONY FRAMES AND SHEATHING SHALL BE EXTERIOR GRADE. BALCONY SHEATHING SHALL BE 3/4" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, 48/24, EXTERIOR, SQUARE EDGE (OR TONGUE-AND-GROOVE ). 12. ROOF, FLOOR AND BALCONY PANEL EDGES SHALL HAVE APPROVED TONGUE-AND-GROOVE JOINTS OR SHALL BE SUPPORTED WITH BLOCKING. 1-1/2" THICK PANELS WITH 1/4" MINIMUM THICKNESS UNDERLAYMENT OR 1-1/2" OF APPROVED LIGHTWEIGHT CONCRETE PLACED OVER THE SUB-FLOOR, DO NOT REQUIRE BLOCKING AT THE EDGES. 13. ALL EXTERIOR WALLS SHALL BE SHEATHED ON THE OUTSIDE OF THE WALL, INCLUDING GABLES, AND THE CONNECTION OF THE SHEATHING TO FRAMING. SHEATHING SHALL BE 15/32" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, STRUCTURAL-I, WITH EXTERIOR GLUE, (EXPOSURE1 OR EXTERIOR), SQURE EDGE. 14. ALL SHEATHING SHALL BE LAID CONTINUOUS OVER TWO OR MORE SUPPORTS WITH FACE GRAIN PERPENDICULAR TO SUPPORTS (UNLESS SHOWN OTHERWISE). STAGGER ALL SHEATHING PANELS A MINIMUM OF ONE JOIST BAY. 15. UNO PER SHEAR WALL SCHEDULE, OR SHOWN ON THE THESE DRAWINGS ALL SHEATHING SHALL BE NAILED TO THE FARMING AS FOLLOWS: 15.1. FASTENERS SHALL BE 10d COMMON NAILS 15.2. SPACING AT BOUNDARIES AND AT SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6 IN. 15.3. SPACING AT INTERMEDIATE FRAMING (FIELD NAILING, F.N.) SHALL NOT BE MORE THAN 12 IN. 15.4. FASTENER PENETRATION IN FRAMING WOOD SHALL NOT BE LESS THAN 1-1/2 IN. 15.5. BLOCK ALL EDGES 15.6. USE 3X LUMBER AT THE CONNECTION OF TWO PANEL EDGES, UNO ON PLANS OR DETAILS. 16. ROOF PLYWOOD SHEATHING SHALL BE CONTINUED BENEATH THE CALIFORNIA FRAMING, IF APPLICABLE. 17. ALL WOOD STRUCTURAL PANEL JOINT AND SILL PLATE NAILING SHALL BE STAGGERED AT ALL PANEL EDGES. 18. BEARING WALLS SHALL BE SHEATHED ON NOT LESS THAN ONE SIDE OR BRIDGING SHALL BE INSTALLED NOT GREATER THAN 4 FEET APART MEASURED VERTICALLY FROM EITHER END OF THE STUD. 2x BLK'G SHALL BE PROVIDED AT PLYWOOD JOINTS FOR ALL WALLS. 19. ROOF AND FLOOR DIAPHRAGM NAILING SHALL BE INSPECTED BEFORE COVERING. 20. NO PENETRATIONS ARE ALLOWED THROUGH SHEARWALL UNLESS SPECIFICALLY DETAILED ON THESE NOTES. 21. ALL POST TO BEAM AND BEAM TO POST SHALL BE CONNECT W/ CCQ/ECCQ UNO ON PLAN. 22. ALL BEAMS ARE FLUSH (NOT DROPPED) UNO ON PLAN. 23. EXTERIOR CONSTRUCTION INCLUDING BALCONY, PATIO LUMBERS AND TIMBERS SHALL BE PRESSURE-TREATED AND GRADE 1 OR BETTER AND CLASSIFIED FOR EXTERIOR CONSTRUCTION, DECK BOARDS, JOISTS & BEAM ABOVE GROUND SHALL BE CATEGORY 3B OR HIGHER AND POSTS SHALL BE CATEGORY 4A OR HIGHER AS SPECIFIED BY AWPA STANDARD U1. 24. PATIO COVER SHEATHING OVER JOISTS NOT SPACED MORE THAN 24" O.C. SHALL BE 19/32" APA RATED WITH SPAN RATING 32/16 EXTERIOR EXPOSURE. NAILS SHALL BE 8D WITH MINIMUM FASTENER PENETRATION IN FRAMING WOOD OF 1-3/8 INCHES. NAIL SPACING AT INTERMEDIATE FRAMING FIELD NAILING) SHALL BE MORE THAN 12 IN. NAIL SPACING AT BOUNDARIES AND AT SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6 IN. 25. IF EXISTING CONSTRUCTION IS INCLUDED IN THIS SCOPE OF WORK, ABOVE MENTIONED SHEATHING REQUIREMENT SHALL BE VERIFIED FOR EXISTING ROOF, FLOOR, AND WALLS THAT ARE INCLUDED WITH THIS SCOPE OF WORK.SEE GYPSUM BOARD AND EXPANDED METAL OR WOVEN WIRE LATH AND PORTLAND CEMENT PLASTER (STUCCO) FOR THE INSTALLATION OF STUCCO AND DRYWALLS. 26. SEE TYPICAL WALL DETAILS FOR THE ADDITIONAL INFORMATION ON HEADERS, KING STUDS AND JACK STUDS. 27. SEE GYPSUM BOARD AND EXPANDED METAL OR WOVEN WIRE LATH AND PORTLAND CEMENT PLASTER (STUCCO) NOTES FOR THE INSTALLATION OF STUCCO AND DRYWALLS. 28. SOLAR PANEL DESIGN AND CONNECTIONS TO THE SUPPORTING ELEMENTS ARE NOT INCLUDED IN THE STRUCTURAL SCOPE OF WORK. A MAXIMUM DEAD-LOAD OF 3 PSF WAS CONSIDERED IN THE STRUCTURAL DESIGN. THE GC SHALL INFORM STRUCTURAL ENGINEER IN WRITING, IF A HEAVIER SOLAR SYSTEM IS USED IN CONSTRUCTION. 29.ALL HANGERS ,COLUMN CAPS ,AND COLUMN BASES ARE MINIMUM REQUIREMENTS ,PRIOR TO ORDER ALL OF THEM SHALL BE CHECKED BY THE CONTRACTOR / FRAMER ANY DISCREPANCY SHALL BE REPORTED TO SEOR. ALL SKEWED HANGERS SHALL BE FIELD-VERIFIED FOR LEFT-HAND OR RIGHT-HAND ORIENTATION, AND THE EXACT SKEW ANGLE SHALL MATCH THE ARCHITECTURAL DRAWINGS. CONTRACTOR TO ENSURE CORRECT HANGER PLACEMENT PRIOR TO INSTALLATION. 30. ALL STEEL CONNECTORS INCLUDING BOLTS, SCREWS AND NAILS USED IN EXTERIOR STRUCTURE OR EXPOSED TO WEATHER SHALL BE STAINLESS STEEL OR HOT-DIP GALVANIZED. FASTENERS IN PRESERVATIVE TREATED WOOD OR FIRE RETARDANT TREATED WOOD SHALL BE OF HOT DIPPED ZINC COATED GALVANIZED STEEL OR STAINLESS STEEL. 31. PROVIDE ONE INTERMEDIATE AND END FULL HEIGHT SOLID BLOCKING ALONG ALL THE JOISTS BEAMS AND RAFTERS WITH SPANS GREATER THAN 8 FT BUT LESS THAN 16 FT. THE INTERMEDIATE BLOCKING SHALL BE SPACED MID-SPAN OF THE JOIST. 32. PROVIDE TWO INTERMEDIATE AND END FULL HEIGHT SOLID BLOCKING ALONG ALL THE JOISTS BEAMS AND RAFTERS WITH SPANS GREATER THAN 16 FT BUT LESS THAN 24 FT. THE INTERMEDIATE BLOCKING SHALL BE SPACED 1/3 OF THE SPAN FROM EACH END. 33. PROVIDE THREE INTERMEDIATE AND END FULL HEIGHT SOLID BLOCKING ALONG ALL THE JOISTS BEAMS AND RAFTERS WITH SPANS GREATER THAN 24 FT. THE INTERMEDIATE BLOCKING SHALL BE SPACED NOT MORE THAN 8 FT ALONG THE SPAN FROM EACH OTHER. 34. THE LOCATION ,DIMENSIONS ,AND SPECIFIC REQUIREMENTS FOR MECHANICAL EQUIPMENT PADS, INCLUDING HEAT PUMP UNITS AND CONDENSERS, SHALL BE COORDINATED BY THE ARCHITECT WITH THE MECHANICAL ENGINEER, EQUIPMENT MANUFACTURER, AND OTHER RELEVANT DISCIPLINES. FINAL PAD DIMENSIONS, CLEARANCES, ANCHORAGE REQUIREMENTS, AND EQUIPMENT LOADS SHALL BE PROVIDED BY THE MECHANICAL ENGINEER AND/OR MANUFACTURER. 35. THE STRUCTURAL ENGINEER OF RECORD (SEOR) SHALL PROVIDE THE STRUCTURAL DESIGN OF THE PAD (E.G., THICKNESS, REINFORCEMENT) BASED SOLELY ON THE MECHANICAL LOADING AND LOCATION INFORMATION FURNISHED BY OTHERS. THE SEOR ASSUMES NO RESPONSIBILITY FOR DETERMINING EQUIPMENT LOCATION, UTILITY COORDINATION, ACCESSIBILITY, SERVICE CLEARANCE, VIBRATION ISOLATION, OR CONFORMANCE WITH MECHANICAL/ELECTRICAL CODES. 36. ANY CHANGE IN EQUIPMENT WEIGHT, CONFIGURATION, OR LAYOUT SHALL BE COMMUNICATED TO THE SEOR FOR VERIFICATION OF STRUCTURAL ADEQUACY PRIOR TO CONSTRUCTION. 3 S1.25 4x10 (UP-STAND BEAM) 4 S4.01 C44 W/4 - A 3 4 2 INDICATES TENSION STRAP INDICATES SHEARWALL TYPE FOR SHEARWALL SCHEDULE SEE 1/S1.21 INDICATES MINIMUM LENGTH OF SHEARWALL SWXX (#'-#") INDICATES WOOD BEAM INDICATES WOOD HEADER SEE 2/S1.24 FOR MORE INFORMATION RB INDICATES HOLDOWN TYPE X INDICATES STEEL SECTION POST MARK, ALL POSTS ARE STEEL SECTION UNO ON PLANS HDR INDICATES WOOD POST MARK, SEE POST SCHEDULE C# HDU X INDICATES RIGID CONNECTIONS INDICATES JOIST INDICATES HANGER J# # S#.##INDICATES SECTION INDICATES SHEET NUMBER INDICATES DETAIL NUMBER ON THE SHEET S#.## # INDICATES CALLOUT # INDICATES REVISION ON DRAWINGS INDICATES VIEW# S#.##INDICATES LOAD BEARING WALL BW INDICATES WOOD HEADER SEE HEADER SCHEDULE TABLE ON PLAN HDR-#EXTENT JOIST DIRECTION DATE: P.M.: DRAWN BY: JOB NO.: 30211 Avenida de las Banderas, Suite 200, Rancho Santa Margarita, California, 92688 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D E SI GN B U I L D CNI UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT REV DATE REMARKS M.A. ISSUED FOR PERMIT12.17.20240 07.13.2025 20241149 ISSUED PER CITY COMMENT07.13.20251 ISSUED PER CITY COMMENT09.28.20252 S2.11 CEILING PLAN 09/28/2025 EXP. 06-30-2026 LANDING STRUCTURAL PLAN SCHEDULE STRUCTURAL PLAN NOTES SCALE: 1/4"=1'-0"CEILING PLAN1 INDICATES TENSION STRAP INDICATES SHEARWALL TYPE FOR SHEARWALL SCHEDULE SEE 1/S1.21 INDICATES MINIMUM LENGTH OF SHEARWALL SWXX (#'-#") INDICATES WOOD BEAM INDICATES WOOD HEADER SEE 2/S1.24 FOR MORE INFORMATION RB INDICATES HOLDOWN TYPE X INDICATES STEEL SECTION POST MARK, ALL POSTS ARE STEEL SECTION UNO ON PLANS HDR INDICATES WOOD POST MARK, SEE POST SCHEDULE C# HDU X SYMBOL DESCRIPTIONS INDICATES RIGID CONNECTIONS INDICATES JOIST INDICATES HANGER J# # S#.##INDICATES SECTION INDICATES SHEET NUMBER INDICATES DETAIL NUMBER ON THE SHEET S#.## # INDICATES CALLOUT #INDICATES REVISION ON DRAWINGS INDICATES VIEW# S#.## INDICATES LOAD BEARING WALL BW INDICATES WOOD HEADER SEE HEADER SCHEDULE TABLE ON PLAN HDR-# HDR-2 HDR-1 CA. W/B C 4 0CA. W/B C 4 0 HDR-1 HD R - 1 C44 W/B C 4 C44 C44 W/4 - A 3 4 HDR-2HDR-2 HDR-1 CJ-1 C44 CJ-1 CJ-1 HD R - 1 CA. W/B C 4 0 HDR-1 CJ-1 4x 1 0 ( U P - S T A N D B E A M ) 4x 1 0 ( U P - S T A N D B E A M ) 4x8 (UP-STAND BEAM) CJ-1 CJ-1 DBL. 2x6 W/ LUS26-2 SW1 (13'-10") SW1 (8'-2") SW1 (2'-8") C44 HDU 2 HDU 2 4x10 (UP-STAND BEAM) WS P (1 7 ' - 3 " ) WS P (2 5 ' - 9 " ) SW 1 (1 3 ' - 0 " ) S1.23 4 CA. W/B C 4 0 TYP LUS410 HHUS46 HHUS46 6 S1.21 TYP 7 S1.22 TYP 3 S1.23 1 S4.01 TYP 3 S4.01 C44 S1.23 1 TYP REVIEW THE PLAN NOTES AND PERFORM FIELD CONDITION ASSESSMENT AND VERIFICATION PRIOR TO COMMENCING THE WORK. HD R HDR HDR C44 C44 C44 CJ-1 CJ-1 C44HDU 2 C44 HDU 2 CJ-1 C44 HDU 2 C44 CJ-1 C44HDU 2 HDU 2 C44 HDU 2 C44HDU 2 HEADER SCHEDULE UNO ON PLAN MARK HEADER SIZE JACK STUD SIZE KING STUD SIZE HANGER HDR-1 4x6 2x4 2x4 N/A HDR-2 4x8 2x4 2x4 N/A POST SCHEDULE UNO ON PLAN MARK POST SIZE C44 4x4 JOIST & HANGER SCHEDULE UNO ON PLAN MARK JOIST SIZE HANGER CJ-1 2x6 @16" O.C.LU26 STUD WALL SCHEDULE UNO ON PLAN/SHEAR WALL SCHED. MAX. HEIGHT INT. WALL EXT. WALL 8'-0"2x4 @16" O.C.2x4 @16" O.C. C44 W/4 - A 3 4 C44HDU 2 DBL.2x6 W/LUS26-2 SEE 2/S1.22 6 S1.22 1 A B C D 2 3 4 CJ-1 HDR-1 C44 W/4 - A 3 4 MST48 MST48 MST48 4x8 MST48 C44 W/B C 4 MST48 1 S4.01 C44 W/4 - A 3 4 DBL. 2x6 W/ LUS26-2 1. TH E S E DR A WING AR E BA S ED O N T HE BEST A VAILA B LE SO UR CES A N D DO N OT A DD RE S S TH E FI E LD CONDITIONS. THE CONTRACTOR SHALL VERIFY ALL FIELD CONDITIONS AND ALL EXISTING STR UCTURAL E L E M E N T S S P E C I F I E D A S V E R I F I E D I N F I E L D (V .I .F .) P R I O R T O C O M M E N C I N G T H E W O R K . A N Y DISCREPANCIES BETWEEN THESE DRAWINGS AND FIELD CONDITIONS SHALL BE REPORTED TO THE AEOR AND SEOR. NO WOR K SHALL BE PER FOR MED IN THE A FFECTED AR EAS UNT I L THE DISCREPAN CIES AR E RESOLVED. 2. NO CUTTING, DRILLING, DEMOLITION OR DESTRUCTIVE WORK ON CONCRETE OR WOOD ELEMENTS SHALL BE PERMITTED UNLESS ALL REINFORCING STEEL INCLUDING PT TENDONS, BEARING WALLS, SHEAR WALLS, BEAMS,AND DIRECTIONS OF JOISTS AND RAFTERS THAT WILL BE AFFECTED ARE POSITIVELY IDENTIFIED. 3. C O N T R A CTO R I S S OLE LY R E S P ON S I BLE FO R P R O T EC T IO N O F ALL STR UC T U R A L , N ONST R UCT U R A L , ARCHITECTURAL, FINISHING, ELECTRICAL AND MECHANICAL COMPONENTS WHICH ARE NOT DESIGNATED FOR DEMOLITION OR NEW CONSTRUCTION. ANY DAMAGES CAUSED BY THE CONTRACTOR OR SUBCONTRACTORS SHALL BE REPAIRED BY THE CONTRACTOR AT NO COSTS TO THE ENGINEERS OR OWNER. 4. STRUCTURAL DRAWINGS ARE NOT STAND-ALONE DOCUMENTS AND ARE INTENDED TO BE USED IN CONJUNCTION WITH CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND DRAWINGS FROM OTHER DISCIPLINES. THE CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS INTO THE SHOP DRAWINGS AND FIELD WORK. 5. ALL ELEVATIONS, SLOPES, DRAINAGE, DIMENSIONS OF OPENINGS, PENETRATIONS, DEPRESSIONS, AND LAYOUT AND GEOMETRY OF NONSTRUCTURAL ELEMENT SUCH AS BUT NOT LIMITED TO PARTITION, WINDOWS, PLUMBING, ARE NOT INCLUDED IN THE STRUCTURAL ENGINEERING SCOPE OF WORK AND SHALL NOT BE THE RESPONSIBILITY OF THE STRUCTURAL ENGINEER. REFER TO THE DRAWINGS FROM OTHER PROFESSIONS FOR THE INFORMATION MENTIONED ABOVE. 6. REVIEW ALL NOTES PROVIDED IN FRAMING LUMBER AND ENGINEERED WOOD PRODUCT SECTION FOR GENERAL REQUIREMENTS AND CONFORMANCE OF STRUCTURAL WOOD. 7. FOR TYPICAL DETAILS SEE S1 SERIES SHEETS. 8. ROOF SHEATHING OVER ROOF RAFTER/JOISTS NOT SPACED MORE THAN 16" O.C. SHALL BE 15/32" OR 1/2" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, 32/16 ,EXTERIOR GRADE AND WITH EXTERIOR GLUE, (EXPOSURE1 OR EXTERIOR), SQUARE EDGE (OR TONGUE-AND-GROOVE). NAILS SHALL BE 8d WITH MINIMUM FASTENER PENETRATION IN FRAMING WOOD FOR 1-3/8 IN. NAIL SPACING AT INTERMEDIATE FRAMING (FIELD NAILING) SHALL NOT BE MORE THAN 12 IN. NAIL SPACING AT BOUNDARIES AND AT SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6 IN. IF OSB PANELS ARE USED, PANELS SHALL BE MOISTURE PROTECTED DURING THE CONSTRUCTION. 9. ROOF SHEATHING OVER RAFTERS/JOISTS OR TRUSSES SPACED AT 24" O.C. SHALL BE 19/32" OR 5/8" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, 40/20 ,EXTERIOR GRADE AND WITH EXTERIOR GLUE, (EXPOSURE1 OR EXTERIOR), SQUARE EDGE (OR TONGUE-AND-GROOVE) IF OSB PANELS ARE USED, PANELS SHALL BE MOISTURE PROTECTED DURING THE CONSTRUCTION.THE ROOF SHEATHING TO BE APPROVED BY THE BUILDING INSPECTOR BEFORE APPLICATION OF ROOFING. 10. FLOOR SHEATHING SHALL BE 23/32" OR 3/4" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, 48/24 WITH EXTERIOR GLUE, (EXPOSURE 1 OR EXTERIOR), SQUAERE EDGE (OR TONGUE-AND-GROOVE ).NAILS SHALL BE 10d WITH MINIMUM FASTENER PENETRATION IN FRAMING WOOD FOR 1-3/8 IN. NAIL SPACING AT INTERMEDIATE FRAMING (FIELD NAILING) SHALL NOT BE MORE THAN 12 IN. NAIL SPACING AT BOUNDARIES AND AT SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6 IN, U.N.O. ON PLANS. 11. BALCONY FRAMES AND SHEATHING SHALL BE EXTERIOR GRADE. BALCONY SHEATHING SHALL BE 3/4" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, 48/24, EXTERIOR, SQUARE EDGE (OR TONGUE-AND-GROOVE ). 12. ROOF, FLOOR AND BALCONY PANEL EDGES SHALL HAVE APPROVED TONGUE-AND-GROOVE JOINTS OR SHALL BE SUPPORTED WITH BLOCKING. 1-1/2" THICK PANELS WITH 1/4" MINIMUM THICKNESS UNDERLAYMENT OR 1-1/2" OF APPROVED LIGHTWEIGHT CONCRETE PLACED OVER THE SUB-FLOOR, DO NOT REQUIRE BLOCKING AT THE EDGES. 13. ALL EXTERIOR WALLS SHALL BE SHEATHED ON THE OUTSIDE OF THE WALL, INCLUDING GABLES, AND THE CONNECTION OF THE SHEATHING TO FRAMING. SHEATHING SHALL BE 15/32" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, STRUCTURAL-I, WITH EXTERIOR GLUE, (EXPOSURE1 OR EXTERIOR), SQURE EDGE. 14. ALL SHEATHING SHALL BE LAID CONTINUOUS OVER TWO OR MORE SUPPORTS WITH FACE GRAIN PERPENDICULAR TO SUPPORTS (UNLESS SHOWN OTHERWISE). STAGGER ALL SHEATHING PANELS A MINIMUM OF ONE JOIST BAY. 15. UNO PER SHEAR WALL SCHEDULE, OR SHOWN ON THE THESE DRAWINGS ALL SHEATHING SHALL BE NAILED TO THE FARMING AS FOLLOWS: 15.1. FASTENERS SHALL BE 10d COMMON NAILS 15.2. SPACING AT BOUNDARIES AND AT SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6 IN. 15.3. SPACING AT INTERMEDIATE FRAMING (FIELD NAILING, F.N.) SHALL NOT BE MORE THAN 12 IN. 15.4. FASTENER PENETRATION IN FRAMING WOOD SHALL NOT BE LESS THAN 1-1/2 IN. 15.5. BLOCK ALL EDGES 15.6. USE 3X LUMBER AT THE CONNECTION OF TWO PANEL EDGES, UNO ON PLANS OR DETAILS. 16. ROOF PLYWOOD SHEATHING SHALL BE CONTINUED BENEATH THE CALIFORNIA FRAMING, IF APPLICABLE. 17. ALL WOOD STRUCTURAL PANEL JOINT AND SILL PLATE NAILING SHALL BE STAGGERED AT ALL PANEL EDGES. 18. BEARING WALLS SHALL BE SHEATHED ON NOT LESS THAN ONE SIDE OR BRIDGING SHALL BE INSTALLED NOT GREATER THAN 4 FEET APART MEASURED VERTICALLY FROM EITHER END OF THE STUD. 2x BLK'G SHALL BE PROVIDED AT PLYWOOD JOINTS FOR ALL WALLS. 19. ROOF AND FLOOR DIAPHRAGM NAILING SHALL BE INSPECTED BEFORE COVERING. 20. NO PENETRATIONS ARE ALLOWED THROUGH SHEARWALL UNLESS SPECIFICALLY DETAILED ON THESE NOTES. 21. ALL POST TO BEAM AND BEAM TO POST SHALL BE CONNECT W/ CCQ/ECCQ UNO ON PLAN. 22. ALL BEAMS ARE FLUSH (NOT DROPPED) UNO ON PLAN. 23. EXTERIOR CONSTRUCTION INCLUDING BALCONY, PATIO LUMBERS AND TIMBERS SHALL BE PRESSURE-TREATED AND GRADE 1 OR BETTER AND CLASSIFIED FOR EXTERIOR CONSTRUCTION, DECK BOARDS, JOISTS & BEAM ABOVE GROUND SHALL BE CATEGORY 3B OR HIGHER AND POSTS SHALL BE CATEGORY 4A OR HIGHER AS SPECIFIED BY AWPA STANDARD U1. 24. PATIO COVER SHEATHING OVER JOISTS NOT SPACED MORE THAN 24" O.C. SHALL BE 19/32" APA RATED WITH SPAN RATING 32/16 EXTERIOR EXPOSURE. NAILS SHALL BE 8D WITH MINIMUM FASTENER PENETRATION IN FRAMING WOOD OF 1-3/8 INCHES. NAIL SPACING AT INTERMEDIATE FRAMING FIELD NAILING) SHALL BE MORE THAN 12 IN. NAIL SPACING AT BOUNDARIES AND AT SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6 IN. 25. IF EXISTING CONSTRUCTION IS INCLUDED IN THIS SCOPE OF WORK, ABOVE MENTIONED SHEATHING REQUIREMENT SHALL BE VERIFIED FOR EXISTING ROOF, FLOOR, AND WALLS THAT ARE INCLUDED WITH THIS SCOPE OF WORK.SEE GYPSUM BOARD AND EXPANDED METAL OR WOVEN WIRE LATH AND PORTLAND CEMENT PLASTER (STUCCO) FOR THE INSTALLATION OF STUCCO AND DRYWALLS. 26. SEE TYPICAL WALL DETAILS FOR THE ADDITIONAL INFORMATION ON HEADERS, KING STUDS AND JACK STUDS. 27. SEE GYPSUM BOARD AND EXPANDED METAL OR WOVEN WIRE LATH AND PORTLAND CEMENT PLASTER (STUCCO) NOTES FOR THE INSTALLATION OF STUCCO AND DRYWALLS. 28. SOLAR PANEL DESIGN AND CONNECTIONS TO THE SUPPORTING ELEMENTS ARE NOT INCLUDED IN THE STRUCTURAL SCOPE OF WORK. A MAXIMUM DEAD-LOAD OF 3 PSF WAS CONSIDERED IN THE STRUCTURAL DESIGN. THE GC SHALL INFORM STRUCTURAL ENGINEER IN WRITING, IF A HEAVIER SOLAR SYSTEM IS USED IN CONSTRUCTION. 29.ALL HANGERS ,COLUMN CAPS ,AND COLUMN BASES ARE MINIMUM REQUIREMENTS ,PRIOR TO ORDER ALL OF THEM SHALL BE CHECKED BY THE CONTRACTOR / FRAMER ANY DISCREPANCY SHALL BE REPORTED TO SEOR. 30. ALL STEEL CONNECTORS INCLUDING BOLTS, SCREWS AND NAILS USED IN EXTERIOR STRUCTURE OR EXPOSED TO WEATHER SHALL BE STAINLESS STEEL OR HOT-DIP GALVANIZED. FASTENERS IN PRESERVATIVE TREATED WOOD OR FIRE RETARDANT TREATED WOOD SHALL BE OF HOT DIPPED ZINC COATED GALVANIZED STEEL OR STAINLESS STEEL. 31. PROVIDE ONE INTERMEDIATE AND END FULL HEIGHT SOLID BLOCKING ALONG ALL THE JOISTS BEAMS AND RAFTERS WITH SPANS GREATER THAN 8 FT BUT LESS THAN 16 FT. THE INTERMEDIATE BLOCKING SHALL BE SPACED MID-SPAN OF THE JOIST. 32. PROVIDE TWO INTERMEDIATE AND END FULL HEIGHT SOLID BLOCKING ALONG ALL THE JOISTS BEAMS AND RAFTERS WITH SPANS GREATER THAN 16 FT BUT LESS THAN 24 FT. THE INTERMEDIATE BLOCKING SHALL BE SPACED 1/3 OF THE SPAN FROM EACH END. 33. PROVIDE THREE INTERMEDIATE AND END FULL HEIGHT SOLID BLOCKING ALONG ALL THE JOISTS BEAMS AND RAFTERS WITH SPANS GREATER THAN 24 FT. THE INTERMEDIATE BLOCKING SHALL BE SPACED NOT MORE THAN 8 FT ALONG THE SPAN FROM EACH OTHER. 34. THE LOCATION ,DIMENSIONS ,AND SPECIFIC REQUIREMENTS FOR MECHANICAL EQUIPMENT PADS, INCLUDING HEAT PUMP UNITS AND CONDENSERS, SHALL BE COORDINATED BY THE ARCHITECT WITH THE MECHANICAL ENGINEER, EQUIPMENT MANUFACTURER, AND OTHER RELEVANT DISCIPLINES. FINAL PAD DIMENSIONS, CLEARANCES, ANCHORAGE REQUIREMENTS, AND EQUIPMENT LOADS SHALL BE PROVIDED BY THE MECHANICAL ENGINEER AND/OR MANUFACTURER. 35. THE STRUCTURAL ENGINEER OF RECORD (SEOR) SHALL PROVIDE THE STRUCTURAL DESIGN OF THE PAD (E.G., THICKNESS, REINFORCEMENT) BASED SOLELY ON THE MECHANICAL LOADING AND LOCATION INFORMATION FURNISHED BY OTHERS. THE SEOR ASSUMES NO RESPONSIBILITY FOR DETERMINING EQUIPMENT LOCATION, UTILITY COORDINATION, ACCESSIBILITY, SERVICE CLEARANCE, VIBRATION ISOLATION, OR CONFORMANCE WITH MECHANICAL/ELECTRICAL CODES. 36. ANY CHANGE IN EQUIPMENT WEIGHT, CONFIGURATION, OR LAYOUT SHALL BE COMMUNICATED TO THE SEOR FOR VERIFICATION OF STRUCTURAL ADEQUACY PRIOR TO CONSTRUCTION. HDU 2 4x 1 0 ( U P - S T A N D B E A M ) SW1 (8'-6") C44 HD R - 1 C44 W/B C 4 0 1 ALL WOOD MEMBERS (I.E. PLYWOOD, LUMBER, TIMBER,NAILERS, ETC.) SHALL BE CLASSIFIED FOR EXTERIOR GRADE OR PRESSURE TREATED 3 S1.23 C44 W/B C 4C44 W/B C 4 C44 W/B C 4 HTS30HTS30 2 S4.01 DBL.2x6 W/LUS26-2 SEE 2/S1.22 DB L . 2 x 6 CJ-1 4x 1 0 ( U P - S T A N D B E A M ) C44 HDU 2 C44 W/4 - A 3 4 CJ-1 HD R HDU 2 C44 CA. W/B C 4 0 1 4x 1 0 C44 W/4 - A 3 4 HH4 CA. W/B C 4 0 DATE: P.M.: DRAWN BY: JOB NO.: 30211 Avenida de las Banderas, Suite 200, Rancho Santa Margarita, California, 92688 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D E SI GN B U I L D CNI UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT REV DATE REMARKS M.A. ISSUED FOR PERMIT12.17.20240 07.13.2025 20241149 ISSUED PER CITY COMMENT07.13.20251 S2.11 CEILING PLAN 07/15/2025 EXP. 06-30-2026 STRUCTURAL PLAN SCHEDULE STRUCTURAL PLAN NOTES SCALE: 1/4"=1'-0"ROOF PLAN1 INDICATES TENSION STRAP INDICATES SHEARWALL TYPE FOR SHEARWALL SCHEDULE SEE 1/S1.21 INDICATES MINIMUM LENGTH OF SHEARWALL SWXX (#'-#") INDICATES WOOD BEAM INDICATES WOOD HEADER SEE 2/S1.24 FOR MORE INFORMATION RB INDICATES HOLDOWN TYPE X INDICATES STEEL SECTION POST MARK, ALL POSTS ARE STEEL SECTION UNO ON PLANS HDR INDICATES WOOD POST MARK, SEE POST SCHEDULE C# HDU X SYMBOL DESCRIPTIONS INDICATES RIGID CONNECTIONS INDICATES JOIST INDICATES HANGER J# # S#.##INDICATES SECTION INDICATES SHEET NUMBER INDICATES DETAIL NUMBER ON THE SHEET S#.## # INDICATES CALLOUT #INDICATES REVISION ON DRAWINGS INDICATES VIEW# S#.## INDICATES LOAD BEARING WALL BW INDICATES WOOD HEADER SEE HEADER SCHEDULE TABLE ON PLAN HDR-# RR-1 4x8 CO N T . 4 x 1 0 CO N T . 4 x 1 0 RR-1 RR-1 RR-1RR-1 RR-1 RR-1 FLA T S L E E P E R FLA T S L E E P E R SW1 (13'-10") SW1 (8'-6") SW1 (8'-2") SW1 (2'-8") SW 1 (1 3 ' - 0 " ) MSTA49 W/RR-1 WS P (1 7 ' - 3 " ) WS P (2 5 ' - 9 " ) 5 S1.21 S1.21 7 MSTC40 HHRC44 S1.22 3 4x8 TYP TYP TYP 6 S1.21 TYP 4 S1.22 TYP 9 S1.22 7 S1.22 TYP S1.22 5 TYP REVIEW THE PLAN NOTES AND PERFORM FIELD CONDITION ASSESSMENT AND VERIFICATION PRIOR TO COMMENCING THE WORK. POST SCHEDULE UNO ON PLAN MARK POST SIZE C44 4x4 JOIST & HANGER SCHEDULE UNO ON PLAN MARK JOIST SIZE HANGER RR-1 2x8 @16" O.C.LRU26Z / LSSJ26Z C44C44 4x8 4x8 RR-1 C44 W/B C 4 4x8 4x8 C44 C44 CONT. 4X8 RR-1 RR-1 C44 C44 C44 C44 C44 C44C44 C44 C44 HHRC44 C44 W/B C 4 C44 W/B C 4 C44 6 S1.22 1 A B C D 2 3 4 MSTA49 MST48 MST48 C44 MSTA49 W/RR-1 C44 W/C C Q 4 4 MSTA49 W/RR-1 HHRC44 MST48 SEE DETAIL 8/S1.21 2 S4.01 C44C44C44 MSTA49 1. TH E S E DR A WING AR E BA S ED O N T HE BEST A VAILA B LE SO UR CES A N D DO N OT A DD RE S S TH E FI E LD CONDITIONS. THE CONTRACTOR SHALL VERIFY ALL FIELD CONDITIONS AND ALL EXISTING STR UCTURAL E L E M E N T S S P E C I F I E D A S V E R I F I E D I N F I E L D (V .I .F .) P R I O R T O C O M M E N C I N G T H E W O R K . A N Y DISCREPANCIES BETWEEN THESE DRAWINGS AND FIELD CONDITIONS SHALL BE REPORTED TO THE AEOR AND SEOR. NO WOR K SHALL BE PER FOR MED IN THE A FFECTED AR EAS UNT I L THE DISCREPAN CIES AR E RESOLVED. 2. NO CUTTING, DRILLING, DEMOLITION OR DESTRUCTIVE WORK ON CONCRETE OR WOOD ELEMENTS SHALL BE PERMITTED UNLESS ALL REINFORCING STEEL INCLUDING PT TENDONS, BEARING WALLS, SHEAR WALLS, BEAMS,AND DIRECTIONS OF JOISTS AND RAFTERS THAT WILL BE AFFECTED ARE POSITIVELY IDENTIFIED. 3. C O N T R A CTO R I S S OLE LY R E S P ON S I BLE FO R P R O T EC T IO N O F ALL STR UC T U R A L , N ONST R UCT U R A L , ARCHITECTURAL, FINISHING, ELECTRICAL AND MECHANICAL COMPONENTS WHICH ARE NOT DESIGNATED FOR DEMOLITION OR NEW CONSTRUCTION. ANY DAMAGES CAUSED BY THE CONTRACTOR OR SUBCONTRACTORS SHALL BE REPAIRED BY THE CONTRACTOR AT NO COSTS TO THE ENGINEERS OR OWNER. 4. STRUCTURAL DRAWINGS ARE NOT STAND-ALONE DOCUMENTS AND ARE INTENDED TO BE USED IN CONJUNCTION WITH CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND DRAWINGS FROM OTHER DISCIPLINES. THE CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS INTO THE SHOP DRAWINGS AND FIELD WORK. 5. ALL ELEVATIONS, SLOPES, DRAINAGE, DIMENSIONS OF OPENINGS, PENETRATIONS, DEPRESSIONS, AND LAYOUT AND GEOMETRY OF NONSTRUCTURAL ELEMENT SUCH AS BUT NOT LIMITED TO PARTITION, WINDOWS, PLUMBING, ARE NOT INCLUDED IN THE STRUCTURAL ENGINEERING SCOPE OF WORK AND SHALL NOT BE THE RESPONSIBILITY OF THE STRUCTURAL ENGINEER. REFER TO THE DRAWINGS FROM OTHER PROFESSIONS FOR THE INFORMATION MENTIONED ABOVE. 6. REVIEW ALL NOTES PROVIDED IN FRAMING LUMBER AND ENGINEERED WOOD PRODUCT SECTION FOR GENERAL REQUIREMENTS AND CONFORMANCE OF STRUCTURAL WOOD. 7. FOR TYPICAL DETAILS SEE S1 SERIES SHEETS. 8. ROOF SHEATHING OVER ROOF RAFTER/JOISTS NOT SPACED MORE THAN 16" O.C. SHALL BE 15/32" OR 1/2" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, 32/16 ,EXTERIOR GRADE AND WITH EXTERIOR GLUE, (EXPOSURE1 OR EXTERIOR), SQUARE EDGE (OR TONGUE-AND-GROOVE). NAILS SHALL BE 8d WITH MINIMUM FASTENER PENETRATION IN FRAMING WOOD FOR 1-3/8 IN. NAIL SPACING AT INTERMEDIATE FRAMING (FIELD NAILING) SHALL NOT BE MORE THAN 12 IN. NAIL SPACING AT BOUNDARIES AND AT SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6 IN. IF OSB PANELS ARE USED, PANELS SHALL BE MOISTURE PROTECTED DURING THE CONSTRUCTION. 9. ROOF SHEATHING OVER RAFTERS/JOISTS OR TRUSSES SPACED AT 24" O.C. SHALL BE 19/32" OR 5/8" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, 40/20 ,EXTERIOR GRADE AND WITH EXTERIOR GLUE, (EXPOSURE1 OR EXTERIOR), SQUARE EDGE (OR TONGUE-AND-GROOVE) IF OSB PANELS ARE USED, PANELS SHALL BE MOISTURE PROTECTED DURING THE CONSTRUCTION.THE ROOF SHEATHING TO BE APPROVED BY THE BUILDING INSPECTOR BEFORE APPLICATION OF ROOFING. 10. FLOOR SHEATHING SHALL BE 23/32" OR 3/4" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, 48/24 WITH EXTERIOR GLUE, (EXPOSURE 1 OR EXTERIOR), SQUAERE EDGE (OR TONGUE-AND-GROOVE ).NAILS SHALL BE 10d WITH MINIMUM FASTENER PENETRATION IN FRAMING WOOD FOR 1-3/8 IN. NAIL SPACING AT INTERMEDIATE FRAMING (FIELD NAILING) SHALL NOT BE MORE THAN 12 IN. NAIL SPACING AT BOUNDARIES AND AT SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6 IN, U.N.O. ON PLANS. 11. BALCONY FRAMES AND SHEATHING SHALL BE EXTERIOR GRADE. BALCONY SHEATHING SHALL BE 3/4" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, 48/24, EXTERIOR, SQUARE EDGE (OR TONGUE-AND-GROOVE ). 12. ROOF, FLOOR AND BALCONY PANEL EDGES SHALL HAVE APPROVED TONGUE-AND-GROOVE JOINTS OR SHALL BE SUPPORTED WITH BLOCKING. 1-1/2" THICK PANELS WITH 1/4" MINIMUM THICKNESS UNDERLAYMENT OR 1-1/2" OF APPROVED LIGHTWEIGHT CONCRETE PLACED OVER THE SUB-FLOOR, DO NOT REQUIRE BLOCKING AT THE EDGES. 13. ALL EXTERIOR WALLS SHALL BE SHEATHED ON THE OUTSIDE OF THE WALL, INCLUDING GABLES, AND THE CONNECTION OF THE SHEATHING TO FRAMING. SHEATHING SHALL BE 15/32" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, STRUCTURAL-I, WITH EXTERIOR GLUE, (EXPOSURE1 OR EXTERIOR), SQURE EDGE. 14. ALL SHEATHING SHALL BE LAID CONTINUOUS OVER TWO OR MORE SUPPORTS WITH FACE GRAIN PERPENDICULAR TO SUPPORTS (UNLESS SHOWN OTHERWISE). STAGGER ALL SHEATHING PANELS A MINIMUM OF ONE JOIST BAY. 15. UNO PER SHEAR WALL SCHEDULE, OR SHOWN ON THE THESE DRAWINGS ALL SHEATHING SHALL BE NAILED TO THE FARMING AS FOLLOWS: 15.1. FASTENERS SHALL BE 10d COMMON NAILS 15.2. SPACING AT BOUNDARIES AND AT SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6 IN. 15.3. SPACING AT INTERMEDIATE FRAMING (FIELD NAILING, F.N.) SHALL NOT BE MORE THAN 12 IN. 15.4. FASTENER PENETRATION IN FRAMING WOOD SHALL NOT BE LESS THAN 1-1/2 IN. 15.5. BLOCK ALL EDGES 15.6. USE 3X LUMBER AT THE CONNECTION OF TWO PANEL EDGES, UNO ON PLANS OR DETAILS. 16. ROOF PLYWOOD SHEATHING SHALL BE CONTINUED BENEATH THE CALIFORNIA FRAMING, IF APPLICABLE. 17. ALL WOOD STRUCTURAL PANEL JOINT AND SILL PLATE NAILING SHALL BE STAGGERED AT ALL PANEL EDGES. 18. BEARING WALLS SHALL BE SHEATHED ON NOT LESS THAN ONE SIDE OR BRIDGING SHALL BE INSTALLED NOT GREATER THAN 4 FEET APART MEASURED VERTICALLY FROM EITHER END OF THE STUD. 2x BLK'G SHALL BE PROVIDED AT PLYWOOD JOINTS FOR ALL WALLS. 19. ROOF AND FLOOR DIAPHRAGM NAILING SHALL BE INSPECTED BEFORE COVERING. 20. NO PENETRATIONS ARE ALLOWED THROUGH SHEARWALL UNLESS SPECIFICALLY DETAILED ON THESE NOTES. 21. ALL POST TO BEAM AND BEAM TO POST SHALL BE CONNECT W/ CCQ/ECCQ UNO ON PLAN. 22. ALL BEAMS ARE FLUSH (NOT DROPPED) UNO ON PLAN. 23. EXTERIOR CONSTRUCTION INCLUDING BALCONY, PATIO LUMBERS AND TIMBERS SHALL BE PRESSURE-TREATED AND GRADE 1 OR BETTER AND CLASSIFIED FOR EXTERIOR CONSTRUCTION, DECK BOARDS, JOISTS & BEAM ABOVE GROUND SHALL BE CATEGORY 3B OR HIGHER AND POSTS SHALL BE CATEGORY 4A OR HIGHER AS SPECIFIED BY AWPA STANDARD U1. 24. PATIO COVER SHEATHING OVER JOISTS NOT SPACED MORE THAN 24" O.C. SHALL BE 19/32" APA RATED WITH SPAN RATING 32/16 EXTERIOR EXPOSURE. NAILS SHALL BE 8D WITH MINIMUM FASTENER PENETRATION IN FRAMING WOOD OF 1-3/8 INCHES. NAIL SPACING AT INTERMEDIATE FRAMING FIELD NAILING) SHALL BE MORE THAN 12 IN. NAIL SPACING AT BOUNDARIES AND AT SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6 IN. 25. IF EXISTING CONSTRUCTION IS INCLUDED IN THIS SCOPE OF WORK, ABOVE MENTIONED SHEATHING REQUIREMENT SHALL BE VERIFIED FOR EXISTING ROOF, FLOOR, AND WALLS THAT ARE INCLUDED WITH THIS SCOPE OF WORK.SEE GYPSUM BOARD AND EXPANDED METAL OR WOVEN WIRE LATH AND PORTLAND CEMENT PLASTER (STUCCO) FOR THE INSTALLATION OF STUCCO AND DRYWALLS. 26. SEE TYPICAL WALL DETAILS FOR THE ADDITIONAL INFORMATION ON HEADERS, KING STUDS AND JACK STUDS. 27. SEE GYPSUM BOARD AND EXPANDED METAL OR WOVEN WIRE LATH AND PORTLAND CEMENT PLASTER (STUCCO) NOTES FOR THE INSTALLATION OF STUCCO AND DRYWALLS. 28. SOLAR PANEL DESIGN AND CONNECTIONS TO THE SUPPORTING ELEMENTS ARE NOT INCLUDED IN THE STRUCTURAL SCOPE OF WORK. A MAXIMUM DEAD-LOAD OF 3 PSF WAS CONSIDERED IN THE STRUCTURAL DESIGN. THE GC SHALL INFORM STRUCTURAL ENGINEER IN WRITING, IF A HEAVIER SOLAR SYSTEM IS USED IN CONSTRUCTION. 29.ALL HANGERS ,COLUMN CAPS ,AND COLUMN BASES ARE MINIMUM REQUIREMENTS ,PRIOR TO ORDER ALL OF THEM SHALL BE CHECKED BY THE CONTRACTOR / FRAMER ANY DISCREPANCY SHALL BE REPORTED TO SEOR. 30. ALL STEEL CONNECTORS INCLUDING BOLTS, SCREWS AND NAILS USED IN EXTERIOR STRUCTURE OR EXPOSED TO WEATHER SHALL BE STAINLESS STEEL OR HOT-DIP GALVANIZED. FASTENERS IN PRESERVATIVE TREATED WOOD OR FIRE RETARDANT TREATED WOOD SHALL BE OF HOT DIPPED ZINC COATED GALVANIZED STEEL OR STAINLESS STEEL. 31. PROVIDE ONE INTERMEDIATE AND END FULL HEIGHT SOLID BLOCKING ALONG ALL THE JOISTS BEAMS AND RAFTERS WITH SPANS GREATER THAN 8 FT BUT LESS THAN 16 FT. THE INTERMEDIATE BLOCKING SHALL BE SPACED MID-SPAN OF THE JOIST. 32. PROVIDE TWO INTERMEDIATE AND END FULL HEIGHT SOLID BLOCKING ALONG ALL THE JOISTS BEAMS AND RAFTERS WITH SPANS GREATER THAN 16 FT BUT LESS THAN 24 FT. THE INTERMEDIATE BLOCKING SHALL BE SPACED 1/3 OF THE SPAN FROM EACH END. 33. PROVIDE THREE INTERMEDIATE AND END FULL HEIGHT SOLID BLOCKING ALONG ALL THE JOISTS BEAMS AND RAFTERS WITH SPANS GREATER THAN 24 FT. THE INTERMEDIATE BLOCKING SHALL BE SPACED NOT MORE THAN 8 FT ALONG THE SPAN FROM EACH OTHER. 34. THE LOCATION ,DIMENSIONS ,AND SPECIFIC REQUIREMENTS FOR MECHANICAL EQUIPMENT PADS, INCLUDING HEAT PUMP UNITS AND CONDENSERS, SHALL BE COORDINATED BY THE ARCHITECT WITH THE MECHANICAL ENGINEER, EQUIPMENT MANUFACTURER, AND OTHER RELEVANT DISCIPLINES. FINAL PAD DIMENSIONS, CLEARANCES, ANCHORAGE REQUIREMENTS, AND EQUIPMENT LOADS SHALL BE PROVIDED BY THE MECHANICAL ENGINEER AND/OR MANUFACTURER. 35. THE STRUCTURAL ENGINEER OF RECORD (SEOR) SHALL PROVIDE THE STRUCTURAL DESIGN OF THE PAD (E.G., THICKNESS, REINFORCEMENT) BASED SOLELY ON THE MECHANICAL LOADING AND LOCATION INFORMATION FURNISHED BY OTHERS. THE SEOR ASSUMES NO RESPONSIBILITY FOR DETERMINING EQUIPMENT LOCATION, UTILITY COORDINATION, ACCESSIBILITY, SERVICE CLEARANCE, VIBRATION ISOLATION, OR CONFORMANCE WITH MECHANICAL/ELECTRICAL CODES. 36. ANY CHANGE IN EQUIPMENT WEIGHT, CONFIGURATION, OR LAYOUT SHALL BE COMMUNICATED TO THE SEOR FOR VERIFICATION OF STRUCTURAL ADEQUACY PRIOR TO CONSTRUCTION. 1 MST48 C44 1 S4.01 C44 W/B C 4 2x10 RIDGE BOARD DATE: P.M.: DRAWN BY: JOB NO.: 30211 Avenida de las Banderas, Suite 200, Rancho Santa Margarita, California, 92688 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D E SI GN B U I L D CNI UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT REV DATE REMARKS M.A. ISSUED FOR PERMIT12.17.20240 07.13.2025 20241149 ISSUED PER CITY COMMENT07.13.20251 S2.22 ROOF PLAN 07/15/2025 EXP. 06-30-2026 W SCALE:NTS. 1 FLOOR OR ROOF DIAPHRAGM SHEATHING REQUIREMENTS DETAIL A PLAN NOTE: THE LOWER ENDS OF CROSS BRIDGING SHALL BE DRIVEN UP AND NAILED AFTER THE SHEATHING HAS BEEN NAILED. JST. PER PLAN FIELD NAILING B.N. AT ALL CONT. PANEL EDGES PROVIDE 2x BLK'G PER DETAIL A AT BLOCKED DIAPHRAGM DISCONT. EDGE NAILING B.N. SHEATHING SEE PLAN STAG G E R END J O I N T S 4'-0" T Y P . 2'-0" M I N . METAL CROSS BRIDGING PER TJI MANUFACTUREREDGE NAILING TJI PER PLAN 2x4 CONT. W/ 16d@12" O.C. RAFTER OR JOIST. BEYOND AT LAP SPLICE EDGE NAILING SHEATHING JOINT SHEATHING JOINTEDGE NAILING 2x4 FLAT BLK'G W/ (2)10d TOENAILS EA. END RAFTER OR JOIST PER PLAN2x BRIDGING (FULL HEIGHT) 1 1/2" EDGE NAILING 5/16" MAX. 2 1/2" EDGE NAILING 13/16" MAX. 3" EDGE NAILING 1-1/16" MAX.TWO 2x-FRAMING3x-FRAMING2x-FRAMING 1/8" GAP TYP. 3/8" MIN. TYP. DETAIL B DETAIL C DETAIL D 1/8" GAP TYP. 3/8" MIN. TYP. 1/8" GAP TYP. 3/8" MIN. TYP. DETAIL E NOTE: ALL BLOCKED AND UNBLOCKED DIAPHRAGMS (ROOF AND FLOOR) SHALL BE CONSTRUCTED AS FOLLOWS: 1. REVIEW THE PLAN NOTES AND DRAWINGS FOR ADDITIONAL REQUIREMENTS OF FLOOR AND ROOF CONSTRUCTIONS. 2. WOOD STRUCTURAL PANELS SHALL CONFORM TO THE REQUIREMENTS FOR THEIR TYPE IN DOC PS 1 OR DOC PS2. 3. WHERE DIAPHRAGMS ARE DESIGNATED AS BLOCKED, ALL JOINTS IN SHEATHING SHALL OCCUR OVER AND BE FASTENED TO COMMON FRAMING MEMBERS OR COMMON BLK'G. THE SIZE AND SPACING OF FASTENERS AT WOOD-FRAME DIAPHRAGM BOUNDARIES AND PANEL EDGES SHALL BE AS SPECIFIED ON THESE DWGS. 4. PANELS SHALL NOT BE LESS THAN 4' X 8' EXCEPT AT BOUNDARIES AND CHANGES IN FRAMING WHERE MIN. PANEL DIMENSION SHALL BE 24" UNLESS ALL EDGES OF THE UNDERSIZED PANELS ARE SUPPORTED BY AND FASTENED TO FRAMING MEMBERS OR BLK'G. INDIVIDUAL SHEET OF SHEATHING SHALL NOT BE LESS THAN 2'-0" IN THEIR LEAST PLAN DIMENSION NOR LESS THAN 8 SQ.FT. IN AREA. 5. FOR UNBLOCKED DIAPHRAGMS, THE BLK'G BTWN. SUPPORTING STRUCTURAL MEMBERS AT PANEL EDGES IS NOT REQD. 6. NAILS SHALL BE LOCATED AT LEAST 3/8" FROM THE EDGES OF PANELS.MAX. NAIL SPACING AT PANEL EDGES SHALL BE 6" ON CENTER. 7. NAILS ALONG INTERMEDIATE FRAMING MEMBERS AND BLK'G FOR PANELS SHALL BE THE SAME SIZE AS INSTALLED AT THE PANEL EDGES. 8. MAX. NAIL SPACING SHALL BE 6" ON CENTER WHEN SUPPORT SPACING OF 48" ON CENTER IS SPECIFIED AND 12" ON CENTER FOR CLOSER SUPPORT SPACINGS. 9. THE WIDTH OF THE NAILED FACE OF FRAMING MEMBERS AND BLK'G SHALL BE 2" NOMINAL OR GREATER AT ADJOINING PANEL EDGES EXCEPT THAT A 3" NOMINAL OR GREATER WIDTH AT ADJOINING PANEL EDGES AND STAGGERED NAILING AT ALL PANEL EDGES ARE REQD. WHERE: 9.1. NAIL SPACING OF 2-1/2" ON CENTER OR LESS AT ADJOINING PANEL EDGES IS SPECIFIED, OR 9.2. 10D COMMON NAILS HAVING PENETRATION IN-TO FRAMING MEMBERS AND BLK'G OF MORE THAN 1-1/2" ARE SPECIFIED AT 3" ON CENTER OR LESS AT ADJOINING PANEL EDGES. 10. SPECIFIED STRAPS OR HOLDOWN SYSTEM SHALL BE USED TO SPLICE THE WALL TOP PLATES, SILL/BOT PLATES, BEAMS OR OTHER DRAG ELEMENTS. SHEATHING SHALL NOT BE USED TO SPLICE THE PLATES OR BEAMS. 11. TONGUE-AND-GROOVE SHEATHING SHALL BE INSTALLED W/ THE TONGUES UP ON SLOPED OR PITCHED ROOFS W/ PATTERN FACES DOWN. 12. WHERE RAFTER OR JOIST. LAP SPLICE OCCURS AND PLYWOOD JOINT IS CONTINUES,SEE DETAIL B. BRIDGING/BLK'G IS REQD. AT 96" O.C.MAX. SEE DETAILS C AND D. 13. SHEATHING NAILS OR OTHER APPROVED SHEATHING CONNECTORS SHALL BE DRIVEN SUCH THAT THEIR HEAD OR CROWN IS FLUSH W/ THE SURFACE OF THE SHEATHING OVER-DRIVEN NAILS SHALL NOT BE PERMITTED AND SHALL BE DEEMED UNSATISFACTORY. 14. AT UNBLOCKED DIAPHRAGMS, NAIL SPACING AT DIAPHRAGM BOUNDARIES AND SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6” O.C.AND FIELD NAILING SHALL NOT BE SPACED MORE THAN 12”O.C. 15. AT BLOCKED DIAPHRAGMS,NAIL SPACING AT DIAPHRAGM BOUNDARIES AND AT ALL CONTINUES PANEL EDGES SHALL NOT BE MORE THAN 6 IN. NAIL SPACING AT ALL OTHER PANEL EDGES SHALL NOT BE MORE THAN 6 IN. CONT. PANEL JOINT IN BOTH DIRECTIONS SHALL NOT BE PERMITTED. FIELD NAILING SHALL NOT BE SPACED MORE THAN 12” O.C. STRAP DETAIL W SCALE:NTS. SHEATHING PER PLAN 2X RIM JST. BLK'G L L EDGE NAILING PER PLAN NOTE HEADER PER PLAN HORIZONTAL STRAP PER PLAN JACK PER PLAN SHEAR WALL PER PLAN 2X STUDS PER PLAN 16d @12" O.C. SHEATHING PER PLAN JST. PER PLANBLK'G L L HORIZONTAL STRAP PER PLAN POST PER PLAN SHEAR WALL PER PLAN 2X STUDS PER PLAN CONNECTION PER PLAN IF CONNECTION NOT MENTIONED IN PLAN SEE WALL SHEET ON 01/S1.24 KING PER PLAN CONNECTION PER PLAN BEAM PER PLAN 16d @12" O.C. SHEATHING PER PLAN JST. PER PLANBLK'G L L HORIZONTAL STRAP PER PLAN POST PER PLAN SHEAR WALL PER PLAN 2X STUDS PER PLAN CONNECTION PER PLAN BEAM PER PLAN 16d @12" O.C. A35 PER SHEARWALL SCHEDULE A35 PER SHEARWALL SCHEDULE A35 PER SHEARWALL SCHEDULE DBL. 2X TOP PLATE DBL. 2X TOP PLATE DETAIL A STRAP L (MIN. END LENGTH (IN.) INSTALLED IN EVERY HOLE) MIN. FASTENERS CAPACITY(lb) C16 11"(18) 0.148 x 2 1/2 1700 CS14 13"(24) 0.148 x 2 1/2 2390 CMSTC16 19"(48) 0.148 x 2 1 2 4610 CMST14 27"(58) 0.148 x 2 1/2 5770 CMST12 35"(76) 0.148 x 2 1/2 8320 DETAIL B DETAIL C 4 3'-0" 3'-0" SIMPSON CS14 STRAP UNO PER PLANTRUSS TOP CHORD OR ROOF RAFTER PER PLAN ROOF SHEATHING DRAG JACK TRUSS/ ROOF RAFTER W/ E.N. PER PLAN 2x BLK'G W/ E.N. SEE PLAN FOR LENGTH 3'-6" 3'-6" 2x ROOF RAFTER W/ E.N. SIMPSON CS14 STRAP UNO PER PLAN STUD OR POST PER PLAN ROOF SHEATHING ROOF JOISTS SIT ON WALL LINE OF E.N. W SCALE:NTS. 2 DRAG DETAIL ROOF SHEATHING 2xBLK'G @48" O.C 2 BAYS(TYP.) 2xBLK'G @48" O.C. 2 BAYS(TYP.) SIMPSON A35 2x STUD WALL PER PLAN CEILING JOIST PER PLAN 2x RIM JOIST DBL. 2x TOP PLATECEILING JOIST PER PLAN A35@16" O.C. W SCALE:NTS. 3 CEILING JOIST PARALLEL TO NON-SHEAR WALL 2 8d@6" O.C. DATE: P.M.: DRAWN BY: JOB NO.: 30211 Avenida de las Banderas, Suite 200, Rancho Santa Margarita, California, 92688 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D E SI GN B U I L D CNI UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT REV DATE REMARKS M.A. ISSUED FOR PERMIT12.17.20240 07.13.2025 20241149 ISSUED PER CITY PERMIT07.13.20251 ISSUED PER CITY PERMIT09.28.20252 S1.25 TYPICAL WOOD DETAILS 09/28/2025 EXP. 06-30-2026 LANDING STRUCTURAL PLAN SCHEDULE STRUCTURAL PLAN NOTES SCALE: 1/4"=1'-0"CEILING PLAN1 SYMBOL DESCRIPTIONS HDR-2 HDR-1 CA. W/B C 4 0CA. W/B C 4 0 HDR-1 HD R - 1 C44 W/B C 4 C44 C44 W/4 - A 3 4 HDR-2HDR-2 HDR-1 CJ-1 C44 CJ-1 CJ-1 HD R - 1 CA. W/B C 4 0 HDR-1 CJ-1 4x 1 0 ( U P - S T A N D B E A M ) 4x 1 0 ( U P - S T A N D B E A M ) 4x8 (UP-STAND BEAM) CJ-1 CJ-1 DBL. 2x6 W/ LUS26-2 SW1 (13'-10") SW1 (8'-2") SW1 (2'-8") C44 HDU 2 HDU 2 WS P (1 7 ' - 3 " ) WS P (2 5 ' - 9 " ) SW 1 (1 3 ' - 0 " ) S1.23 4 CA. W/B C 4 0 TYP LUS410 HHUS46 HHUS46 6 S1.21 TYP 7 S1.22 TYP 3 S1.23 1 S4.01 TYP 3 S4.01 C44 S1.23 1 TYP REVIEW THE PLAN NOTES AND PERFORM FIELD CONDITION ASSESSMENT AND VERIFICATION PRIOR TO COMMENCING THE WORK. HD R HDR HDR C44 C44 C44 CJ-1 CJ-1 C44HDU 2 C44 HDU 2 CJ-1 C44 HDU 2 C44 CJ-1 C44HDU 2 HDU 2 C44 HDU 2 C44HDU 2 HEADER SCHEDULE UNO ON PLAN MARK HEADER SIZE JACK STUD SIZE KING STUD SIZE HANGER HDR-1 4x6 2x4 2x4 N/A HDR-2 4x8 2x4 2x4 N/A POST SCHEDULE UNO ON PLAN MARK POST SIZE C44 4x4 JOIST & HANGER SCHEDULE UNO ON PLAN MARK JOIST SIZE HANGER CJ-1 2x6 @16" O.C.LU26 STUD WALL SCHEDULE UNO ON PLAN/SHEAR WALL SCHED. MAX. HEIGHT INT. WALL EXT. WALL 8'-0"2x4 @16" O.C.2x4 @16" O.C. C44 W/4 - A 3 4 C44HDU 2 DBL.2x6 W/LUS26-2 SEE 2/S1.22 6 S1.22 1 A B C D 2 3 4 CJ-1 HDR-1 C44 W/4 - A 3 4 MST48 MST48 MST48 4x8 MST48 C44 W/B C 4 MST48 1 S4.01 DBL. 2x6 W/ LUS26-2 HDU 2 4x 1 0 ( U P - S T A N D B E A M ) SW1 (8'-6") C44 HD R - 1 C44 W/B C 4 0 ALL WOOD MEMBERS (I.E. PLYWOOD, LUMBER, TIMBER,NAILERS, ETC.) SHALL BE CLASSIFIED FOR EXTERIOR GRADE OR PRESSURE TREATED 3 S1.23 C44 W/B C 4C44 W/B C 4 C44 W/B C 4 HTS30HTS30 2 S4.01 DBL.2x6 W/LUS26-2 SEE 2/S1.22 DB L . 2 x 6 CJ-1 4x 1 0 ( U P - S T A N D B E A M ) C44 HDU 2 C44 W/4 - A 3 4 CJ-1 HD R HDU 2 C44 CA. W/B C 4 0 4x 1 0 C44 W/4 - A 3 4 HH4 CA. W/B C 4 0 1. TH E S E DR A WING AR E BA S ED O N T HE BEST A VAILA B LE SO UR CES A N D DO N OT A DD RE S S TH E FI E LD CONDITIONS. THE CONTRACTOR SHALL VERIFY ALL FIELD CONDITIONS AND ALL EXISTING STR UCTURAL E L E M E N T S S P E C I F I E D A S V E R I F I E D I N F I E L D (V .I .F .) P R I O R T O C O M M E N C I N G T H E W O R K . A N Y DISCREPANCIES BETWEEN THESE DRAWINGS AND FIELD CONDITIONS SHALL BE REPORTED TO THE AEOR AND SEOR. NO WOR K SHALL BE PER FOR MED IN THE A FFECTED AR EAS UNT I L THE DISCREPAN CIES AR E RESOLVED. 2. NO CUTTING, DRILLING, DEMOLITION OR DESTRUCTIVE WORK ON CONCRETE OR WOOD ELEMENTS SHALL BE PERMITTED UNLESS ALL REINFORCING STEEL INCLUDING PT TENDONS, BEARING WALLS, SHEAR WALLS, BEAMS,AND DIRECTIONS OF JOISTS AND RAFTERS THAT WILL BE AFFECTED ARE POSITIVELY IDENTIFIED. 3. C O N T R A CTO R I S S OLE LY R E S P ON S I BLE FO R P R O T EC T IO N O F ALL STR UC T U R A L , N ONST R UCT U R A L , ARCHITECTURAL, FINISHING, ELECTRICAL AND MECHANICAL COMPONENTS WHICH ARE NOT DESIGNATED FOR DEMOLITION OR NEW CONSTRUCTION. ANY DAMAGES CAUSED BY THE CONTRACTOR OR SUBCONTRACTORS SHALL BE REPAIRED BY THE CONTRACTOR AT NO COSTS TO THE ENGINEERS OR OWNER. 4. STRUCTURAL DRAWINGS ARE NOT STAND-ALONE DOCUMENTS AND ARE INTENDED TO BE USED IN CONJUNCTION WITH CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND DRAWINGS FROM OTHER DISCIPLINES. THE CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS INTO THE SHOP DRAWINGS AND FIELD WORK. 5. ALL ELEVATIONS, SLOPES, DRAINAGE, DIMENSIONS OF OPENINGS, PENETRATIONS, DEPRESSIONS, AND LAYOUT AND GEOMETRY OF NONSTRUCTURAL ELEMENT SUCH AS BUT NOT LIMITED TO PARTITION, WINDOWS, PLUMBING, ARE NOT INCLUDED IN THE STRUCTURAL ENGINEERING SCOPE OF WORK AND SHALL NOT BE THE RESPONSIBILITY OF THE STRUCTURAL ENGINEER. REFER TO THE DRAWINGS FROM OTHER PROFESSIONS FOR THE INFORMATION MENTIONED ABOVE. 6. REVIEW ALL NOTES PROVIDED IN FRAMING LUMBER AND ENGINEERED WOOD PRODUCT SECTION FOR GENERAL REQUIREMENTS AND CONFORMANCE OF STRUCTURAL WOOD. 7. FOR TYPICAL DETAILS SEE S1 SERIES SHEETS. 8. ROOF SHEATHING OVER ROOF RAFTER/JOISTS NOT SPACED MORE THAN 16" O.C. SHALL BE 15/32" OR 1/2" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, 32/16 ,EXTERIOR GRADE AND WITH EXTERIOR GLUE, (EXPOSURE1 OR EXTERIOR), SQUARE EDGE (OR TONGUE-AND-GROOVE). NAILS SHALL BE 8d WITH MINIMUM FASTENER PENETRATION IN FRAMING WOOD FOR 1-3/8 IN. NAIL SPACING AT INTERMEDIATE FRAMING (FIELD NAILING) SHALL NOT BE MORE THAN 12 IN. NAIL SPACING AT BOUNDARIES AND AT SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6 IN. IF OSB PANELS ARE USED, PANELS SHALL BE MOISTURE PROTECTED DURING THE CONSTRUCTION. 9. ROOF SHEATHING OVER RAFTERS/JOISTS OR TRUSSES SPACED AT 24" O.C. SHALL BE 19/32" OR 5/8" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, 40/20 ,EXTERIOR GRADE AND WITH EXTERIOR GLUE, (EXPOSURE1 OR EXTERIOR), SQUARE EDGE (OR TONGUE-AND-GROOVE) IF OSB PANELS ARE USED, PANELS SHALL BE MOISTURE PROTECTED DURING THE CONSTRUCTION.THE ROOF SHEATHING TO BE APPROVED BY THE BUILDING INSPECTOR BEFORE APPLICATION OF ROOFING. 10. FLOOR SHEATHING SHALL BE 23/32" OR 3/4" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, 48/24 WITH EXTERIOR GLUE, (EXPOSURE 1 OR EXTERIOR), SQUAERE EDGE (OR TONGUE-AND-GROOVE ).NAILS SHALL BE 10d WITH MINIMUM FASTENER PENETRATION IN FRAMING WOOD FOR 1-3/8 IN. NAIL SPACING AT INTERMEDIATE FRAMING (FIELD NAILING) SHALL NOT BE MORE THAN 12 IN. NAIL SPACING AT BOUNDARIES AND AT SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6 IN, U.N.O. ON PLANS. 11. BALCONY FRAMES AND SHEATHING SHALL BE EXTERIOR GRADE. BALCONY SHEATHING SHALL BE 3/4" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, 48/24, EXTERIOR, SQUARE EDGE (OR TONGUE-AND-GROOVE ). 12. ROOF, FLOOR AND BALCONY PANEL EDGES SHALL HAVE APPROVED TONGUE-AND-GROOVE JOINTS OR SHALL BE SUPPORTED WITH BLOCKING. 1-1/2" THICK PANELS WITH 1/4" MINIMUM THICKNESS UNDERLAYMENT OR 1-1/2" OF APPROVED LIGHTWEIGHT CONCRETE PLACED OVER THE SUB-FLOOR, DO NOT REQUIRE BLOCKING AT THE EDGES. 13. ALL EXTERIOR WALLS SHALL BE SHEATHED ON THE OUTSIDE OF THE WALL, INCLUDING GABLES, AND THE CONNECTION OF THE SHEATHING TO FRAMING. SHEATHING SHALL BE 15/32" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, STRUCTURAL-I, WITH EXTERIOR GLUE, (EXPOSURE1 OR EXTERIOR), SQURE EDGE. 14. ALL SHEATHING SHALL BE LAID CONTINUOUS OVER TWO OR MORE SUPPORTS WITH FACE GRAIN PERPENDICULAR TO SUPPORTS (UNLESS SHOWN OTHERWISE). STAGGER ALL SHEATHING PANELS A MINIMUM OF ONE JOIST BAY. 15. UNO PER SHEAR WALL SCHEDULE, OR SHOWN ON THE THESE DRAWINGS ALL SHEATHING SHALL BE NAILED TO THE FARMING AS FOLLOWS: 15.1. FASTENERS SHALL BE 10d COMMON NAILS 15.2. SPACING AT BOUNDARIES AND AT SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6 IN. 15.3. SPACING AT INTERMEDIATE FRAMING (FIELD NAILING, F.N.) SHALL NOT BE MORE THAN 12 IN. 15.4. FASTENER PENETRATION IN FRAMING WOOD SHALL NOT BE LESS THAN 1-1/2 IN. 15.5. BLOCK ALL EDGES 15.6. USE 3X LUMBER AT THE CONNECTION OF TWO PANEL EDGES, UNO ON PLANS OR DETAILS. 16. ROOF PLYWOOD SHEATHING SHALL BE CONTINUED BENEATH THE CALIFORNIA FRAMING, IF APPLICABLE. 17. ALL WOOD STRUCTURAL PANEL JOINT AND SILL PLATE NAILING SHALL BE STAGGERED AT ALL PANEL EDGES. 18. BEARING WALLS SHALL BE SHEATHED ON NOT LESS THAN ONE SIDE OR BRIDGING SHALL BE INSTALLED NOT GREATER THAN 4 FEET APART MEASURED VERTICALLY FROM EITHER END OF THE STUD. 2x BLK'G SHALL BE PROVIDED AT PLYWOOD JOINTS FOR ALL WALLS. 19. ROOF AND FLOOR DIAPHRAGM NAILING SHALL BE INSPECTED BEFORE COVERING. 20. NO PENETRATIONS ARE ALLOWED THROUGH SHEARWALL UNLESS SPECIFICALLY DETAILED ON THESE NOTES. 21. ALL POST TO BEAM AND BEAM TO POST SHALL BE CONNECT W/ CCQ/ECCQ UNO ON PLAN. 22. ALL BEAMS ARE FLUSH (NOT DROPPED) UNO ON PLAN. 23. EXTERIOR CONSTRUCTION INCLUDING BALCONY, PATIO LUMBERS AND TIMBERS SHALL BE PRESSURE-TREATED AND GRADE 1 OR BETTER AND CLASSIFIED FOR EXTERIOR CONSTRUCTION, DECK BOARDS, JOISTS & BEAM ABOVE GROUND SHALL BE CATEGORY 3B OR HIGHER AND POSTS SHALL BE CATEGORY 4A OR HIGHER AS SPECIFIED BY AWPA STANDARD U1. 24. PATIO COVER SHEATHING OVER JOISTS NOT SPACED MORE THAN 24" O.C. SHALL BE 19/32" APA RATED WITH SPAN RATING 32/16 EXTERIOR EXPOSURE. NAILS SHALL BE 8D WITH MINIMUM FASTENER PENETRATION IN FRAMING WOOD OF 1-3/8 INCHES. NAIL SPACING AT INTERMEDIATE FRAMING FIELD NAILING) SHALL BE MORE THAN 12 IN. NAIL SPACING AT BOUNDARIES AND AT SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6 IN. 25. IF EXISTING CONSTRUCTION IS INCLUDED IN THIS SCOPE OF WORK, ABOVE MENTIONED SHEATHING REQUIREMENT SHALL BE VERIFIED FOR EXISTING ROOF, FLOOR, AND WALLS THAT ARE INCLUDED WITH THIS SCOPE OF WORK.SEE GYPSUM BOARD AND EXPANDED METAL OR WOVEN WIRE LATH AND PORTLAND CEMENT PLASTER (STUCCO) FOR THE INSTALLATION OF STUCCO AND DRYWALLS. 26. SEE TYPICAL WALL DETAILS FOR THE ADDITIONAL INFORMATION ON HEADERS, KING STUDS AND JACK STUDS. 27. SEE GYPSUM BOARD AND EXPANDED METAL OR WOVEN WIRE LATH AND PORTLAND CEMENT PLASTER (STUCCO) NOTES FOR THE INSTALLATION OF STUCCO AND DRYWALLS. 28. SOLAR PANEL DESIGN AND CONNECTIONS TO THE SUPPORTING ELEMENTS ARE NOT INCLUDED IN THE STRUCTURAL SCOPE OF WORK. A MAXIMUM DEAD-LOAD OF 3 PSF WAS CONSIDERED IN THE STRUCTURAL DESIGN. THE GC SHALL INFORM STRUCTURAL ENGINEER IN WRITING, IF A HEAVIER SOLAR SYSTEM IS USED IN CONSTRUCTION. 29.ALL HANGERS ,COLUMN CAPS ,AND COLUMN BASES ARE MINIMUM REQUIREMENTS ,PRIOR TO ORDER ALL OF THEM SHALL BE CHECKED BY THE CONTRACTOR / FRAMER ANY DISCREPANCY SHALL BE REPORTED TO SEOR. ALL SKEWED HANGERS SHALL BE FIELD-VERIFIED FOR LEFT-HAND OR RIGHT-HAND ORIENTATION, AND THE EXACT SKEW ANGLE SHALL MATCH THE ARCHITECTURAL DRAWINGS. CONTRACTOR TO ENSURE CORRECT HANGER PLACEMENT PRIOR TO INSTALLATION. 30. ALL STEEL CONNECTORS INCLUDING BOLTS, SCREWS AND NAILS USED IN EXTERIOR STRUCTURE OR EXPOSED TO WEATHER SHALL BE STAINLESS STEEL OR HOT-DIP GALVANIZED. FASTENERS IN PRESERVATIVE TREATED WOOD OR FIRE RETARDANT TREATED WOOD SHALL BE OF HOT DIPPED ZINC COATED GALVANIZED STEEL OR STAINLESS STEEL. 31. PROVIDE ONE INTERMEDIATE AND END FULL HEIGHT SOLID BLOCKING ALONG ALL THE JOISTS BEAMS AND RAFTERS WITH SPANS GREATER THAN 8 FT BUT LESS THAN 16 FT. THE INTERMEDIATE BLOCKING SHALL BE SPACED MID-SPAN OF THE JOIST. 32. PROVIDE TWO INTERMEDIATE AND END FULL HEIGHT SOLID BLOCKING ALONG ALL THE JOISTS BEAMS AND RAFTERS WITH SPANS GREATER THAN 16 FT BUT LESS THAN 24 FT. THE INTERMEDIATE BLOCKING SHALL BE SPACED 1/3 OF THE SPAN FROM EACH END. 33. PROVIDE THREE INTERMEDIATE AND END FULL HEIGHT SOLID BLOCKING ALONG ALL THE JOISTS BEAMS AND RAFTERS WITH SPANS GREATER THAN 24 FT. THE INTERMEDIATE BLOCKING SHALL BE SPACED NOT MORE THAN 8 FT ALONG THE SPAN FROM EACH OTHER. 34. THE LOCATION ,DIMENSIONS ,AND SPECIFIC REQUIREMENTS FOR MECHANICAL EQUIPMENT PADS, INCLUDING HEAT PUMP UNITS AND CONDENSERS, SHALL BE COORDINATED BY THE ARCHITECT WITH THE MECHANICAL ENGINEER, EQUIPMENT MANUFACTURER, AND OTHER RELEVANT DISCIPLINES. FINAL PAD DIMENSIONS, CLEARANCES, ANCHORAGE REQUIREMENTS, AND EQUIPMENT LOADS SHALL BE PROVIDED BY THE MECHANICAL ENGINEER AND/OR MANUFACTURER. 35. THE STRUCTURAL ENGINEER OF RECORD (SEOR) SHALL PROVIDE THE STRUCTURAL DESIGN OF THE PAD (E.G., THICKNESS, REINFORCEMENT) BASED SOLELY ON THE MECHANICAL LOADING AND LOCATION INFORMATION FURNISHED BY OTHERS. THE SEOR ASSUMES NO RESPONSIBILITY FOR DETERMINING EQUIPMENT LOCATION, UTILITY COORDINATION, ACCESSIBILITY, SERVICE CLEARANCE, VIBRATION ISOLATION, OR CONFORMANCE WITH MECHANICAL/ELECTRICAL CODES. 36. ANY CHANGE IN EQUIPMENT WEIGHT, CONFIGURATION, OR LAYOUT SHALL BE COMMUNICATED TO THE SEOR FOR VERIFICATION OF STRUCTURAL ADEQUACY PRIOR TO CONSTRUCTION. 3 S1.25 4x10 (UP-STAND BEAM) 4 S4.01 C44 W/4 - A 3 4 2 INDICATES TENSION STRAP INDICATES SHEARWALL TYPE FOR SHEARWALL SCHEDULE SEE 1/S1.21 INDICATES MINIMUM LENGTH OF SHEARWALL SWXX (#'-#") INDICATES WOOD BEAM INDICATES WOOD HEADER SEE 2/S1.24 FOR MORE INFORMATION RB INDICATES HOLDOWN TYPE X INDICATES STEEL SECTION POST MARK, ALL POSTS ARE STEEL SECTION UNO ON PLANS HDR INDICATES WOOD POST MARK, SEE POST SCHEDULE C# HDU X INDICATES RIGID CONNECTIONS INDICATES JOIST INDICATES HANGER J# # S#.##INDICATES SECTION INDICATES SHEET NUMBER INDICATES DETAIL NUMBER ON THE SHEET S#.## # INDICATES CALLOUT # INDICATES REVISION ON DRAWINGS INDICATES VIEW# S#.##INDICATES LOAD BEARING WALL BW INDICATES WOOD HEADER SEE HEADER SCHEDULE TABLE ON PLAN HDR-#EXTENT JOIST DIRECTION DATE: P.M.: DRAWN BY: JOB NO.: 30211 Avenida de las Banderas, Suite 200, Rancho Santa Margarita, California, 92688 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D E SI GN B U I L D CNI UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT REV DATE REMARKS M.A. ISSUED FOR PERMIT12.17.20240 07.13.2025 20241149 ISSUED PER CITY COMMENT07.13.20251 ISSUED PER CITY COMMENT09.28.20252 S2.11 CEILING PLAN 09/28/2025 EXP. 06-30-2026 SIMPSON A35 CALIFORNIA ROOF RAFTER PER PLAN CEILING JOIST PER PLAN 2x BLK'G W/2 ROWS OF SDWS22400DB @12" O.C. 2x BLK'G @48" O.C. (2)ROWS BEAM PER PLAN ROOF RAFTERS PER PLAN BEAM PER PLAN B.N 16d@ 4" O.C. ROOF SHEATHING PER PLAN CEILING JOIST PER PLAN CEILING JOIST PER PLAN HANGER PER PLAN ROOF SHEATHING PER PLAN SHEAR TRANSFER AT CALIFORNIA ROOF TO DRAG BEAM C SCALE:NTS. 1 C SCALE:NTS. 3 SHEAR TRANSFER AT ROOF SIMPSON H2.5ASIMPSON A35 A35 EACH BLOCK U.O.N. PER SHEAR WALL SCHEDULE H2.5A INSTALLED AT 48" O.C. (OR AT PLYWOOD EDGE JOINTS) MI N . 6 " B.N. ROOF SHT'G PER PLAN ROOF RAFTER PER PLAN 1/2 EXT. SHEATHING W/10d @6" EN. 2xRIM 2xBLK'G STRAP PER PLAN E.N E.N 2x LEDGER W/16d@4" 2x BLK'G @16" O.C. BEAM PER PLAN HANGER PER PLAN 7-16d EACH ENDS ROOF SHEATHING PER PLAN RAFTER PER PLAN SHEAR WALL PER PLAN A35 EACH BLOCK U.O.N. PER SHEAR WALL SCHEDULE (N) H2.5A INSTALLED AT 48" O.C. (OR AT PLYWOOD EDGE JOINTS) CEILING JOIST PER PLAN 2x BLK'G @ 48" O.C. 2 BAYS ROOF RAFTER PER PLAN SHEATHING PER PLAN SHEAR WALL PER PLAN2x4@16" CRIPPLE WALL E.N B.N. (N)2xBLK'G @48" O.C. 2 BAYS CEILING JOIST PER PLAN 3x SLOPED BOT,SILL PLATE DBL. TOP PLATE DBL. 2x TOP PLATE (N)E.N 2xRIM B.N 2xLEDGER W/16d@6" O.C. 2x BLK'G @ 48" O.C. 2 BAYS E.N (7)16d MIN. COMMON NAILS EA. END LTP4 PER SHEAR WALL SCHED. C2SCALE:NTS. SHEAR TRANSFER AT CALIFORNIA ROOF FRAMING SIMPSON A35 SIMPSON H2.5A 2xBLK'G @48" O.C 2 BAYS(TYP.) 2xBLK'G @48" O.C. 2 BAYS(TYP.) CEILING JOIST PER PLAN CEILING JOIST PER PLAN BEAM PER PLAN C SCALE:NTS. 4 CEILING JOIST PARALLEL TO BEAM 2 DATE: P.M.: DRAWN BY: JOB NO.: 30211 Avenida de las Banderas, Suite 200, Rancho Santa Margarita, California, 92688 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D E SI GN B U I L D CNI UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT REV DATE REMARKS M.A. ISSUED FOR PERMIT12.17.20240 07.13.2025 20241149 ISSUED PER CITY PERMIT07.13.20251 ISSUED PER CITY PERMIT09.28.20252 S4.01 SPECIFIC DETAILS 09/28/2025 EXP. 06-30-2026 SIMPSON A35 CALIFORNIA ROOF RAFTER PER PLAN CEILING JOIST PER PLAN 2x BLK'G W/2 ROWS OF SDWS22400DB @12" O.C. 2x BLK'G @48" O.C. (2)ROWS BEAM PER PLAN ROOF RAFTERS PER PLAN BEAM PER PLAN B.N 16d@ 4" O.C. ROOF SHEATHING PER PLAN CEILING JOIST PER PLAN CEILING JOIST PER PLAN HANGER PER PLAN ROOF SHEATHING PER PLAN SHEAR TRANSFER AT CALIFORNIA ROOF TO DRAG BEAM C SCALE:NTS. 1 C SCALE:NTS. 3 SHEAR TRANSFER AT ROOF SIMPSON H2.5ASIMPSON A35 A35 EACH BLOCK U.O.N. PER SHEAR WALL SCHEDULE H2.5A INSTALLED AT 48" O.C. (OR AT PLYWOOD EDGE JOINTS) MI N . 6 " B.N. ROOF SHT'G PER PLAN ROOF RAFTER PER PLAN 1/2 EXT. SHEATHING W/10d @6" EN. 2xRIM 2xBLK'G STRAP PER PLAN E.N E.N 2x LEDGER W/16d@4" 2x BLK'G @16" O.C. BEAM PER PLAN HANGER PER PLAN 7-16d EACH ENDS ROOF SHEATHING PER PLAN RAFTER PER PLAN SHEAR WALL PER PLAN A35 EACH BLOCK U.O.N. PER SHEAR WALL SCHEDULE (N) H2.5A INSTALLED AT 48" O.C. (OR AT PLYWOOD EDGE JOINTS) CEILING JOIST PER PLAN 2x BLK'G @ 48" O.C. 2 BAYS ROOF RAFTER PER PLAN SHEATHING PER PLAN SHEAR WALL PER PLAN2x4@16" CRIPPLE WALL E.N B.N. (N)2xBLK'G @48" O.C. 2 BAYS CEILING JOIST PER PLAN 3x SLOPED BOT,SILL PLATE DBL. TOP PLATE DBL. 2x TOP PLATE (N)E.N 2xRIM B.N 2xLEDGER W/16d@6" O.C. 2x BLK'G @ 48" O.C. 2 BAYS E.N (7)16d MIN. COMMON NAILS EA. END LTP4 PER SHEAR WALL SCHED. C2SCALE:NTS. SHEAR TRANSFER AT CALIFORNIA ROOF FRAMING SIMPSON A35 SIMPSON H2.5A DATE: P.M.: DRAWN BY: JOB NO.: 30211 Avenida de las Banderas, Suite 200, Rancho Santa Margarita, California, 92688 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D E SI GN B U I L D CNI UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT REV DATE REMARKS M.A. ISSUED FOR PERMIT12.17.20240 07.13.2025 20241149 ISSUED PER CITY PERMIT07.13.20251 S4.01 SPECIFIC DETAILS 07/15/2025 EXP. 06-30-2026 DATE: P.M.: DRAWN BY: JOB NO.: 26081 Merit Cir, STE 111 Laguna Hills, CA 92653 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D ES I GNBUILDCNI 7/ 2 / 2 0 2 5 1 0 : 2 8 : 5 7 A M A0.3 B.N. -- TITLE 24 07.11.24 2024001108 UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT REV DATE REMARKS DATE: P.M.: DRAWN BY: JOB NO.: 26081 Merit Cir, STE 111 Laguna Hills, CA 92653 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D ES I GNBUILDCNI 7/ 2 / 2 0 2 5 1 0 : 2 9 : 0 2 A M A0.4 B.N. F.M. MANDATORY RESIDENTIAL MEASURES 07.11.24 2024001108 UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT REV DATE REMARKS DATE: P.M.: DRAWN BY: JOB NO.: 26081 Merit Cir, STE 111 Laguna Hills, CA 92653 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D ES I GNBUILDCNI 7/ 2 / 2 0 2 5 1 0 : 2 9 : 0 5 A M A0.5 B.N. F.M. 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 07.11.24 2024001108 UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT REV DATE REMARKS 2 06.25.2025 City Correction 2 DATE: P.M.: DRAWN BY: JOB NO.: 26081 Merit Cir, STE 111 Laguna Hills, CA 92653 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D ES I GNBUILDCNI 7/ 2 / 2 0 2 5 1 0 : 2 9 : 0 5 A M A0.5 B.N. F.M. 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 07.11.24 2024001108 UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT REV DATE REMARKS 2 06.25.2025 City Correction 2 DATE: P.M.: DRAWN BY: JOB NO.: 26081 Merit Cir, STE 111 Laguna Hills, CA 92653 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D ES I GNBUILDCNI 7/ 2 / 2 0 2 5 1 0 : 2 9 : 0 5 A M A0.5 B.N. F.M. 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 07.11.24 2024001108 UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT REV DATE REMARKS 2 06.25.2025 City Correction 2 DATE: P.M.: DRAWN BY: JOB NO.: 26081 Merit Cir, STE 111 Laguna Hills, CA 92653 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D ES I GNBUILDCNI 7/ 2 / 2 0 2 5 1 0 : 2 9 : 0 9 A M A0.6 B.N. F.M. 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 07.11.24 2024001108 UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT REV DATE REMARKS 2 06.25.2025 City Correction 2 KEY NOTE: 1 - CONST. 4" DIA AREA DRAIN ND5 OR APPROVED EQUIVALENT 2 - CONST. 4" DIA SCHEDULE 40 DRAIN PIPE 3- CONST. 12" X12" INLET X- OPEN BOTTOM FILLES W - 1/2" DRAIN ROCK PAD SHALL BE COMPACTED TO ABOVE 90% RELATIVE COMPACTION AND OVER EXCAVATION SHALL BE PER SOILS ENGINEER RECOMMENDATIONS S V A N N E S S P. L . 5 6 . 3 ' P. L . 5 6 . 3 ' P.L. 125' P.L. 125' (E) GARAGE (E) COVERED PORCH (E) COVERED PATIO ADU 730 SF EXISTING HOUSE N.I.C N.I.C THE GRADE SHALL FALL NOT FEWER THAN 6IN WITHIN THE FIRST 10FT. WHERE LOT LINES, WALLS, SLOPES OR OTHER PHYSICAL BARRIERS PROHIBIT 6IN OF FALL WITHIN 10FT, DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. IMPERVIOUS SURFACES WITHIN 10FT OF THE BUILDING FOUNDATION SHALL BE SLOPED NOT LESS THAN 2% AWAY FOR THE BUILDING PER 2022 CRC, SECTION R401.3. 5% SLOPE 2% SLOPE 5% 5% 5% 5% SLOPE 5% SLOPE 2% SLOPE 2% SLOPE 2% SD SD SD SD SD SD 1% 85.85HP/FL 1%1% 85.85HP/FL 1%PIPE = 1% PIPE = 1% 85.85HP/FL 1%1% 85.85HP/FL 1%1% 85.85HP/FL 1% 1% 85.85HP/FL 1% 1% 86.50 FF 86.00 FS 85.70 TG 84.08 INV PIPE = 1% 85.70 TG 84.23 INV 2 185.70 TG 84.45 INV 85.70 TG 84.19 INV DOWNSPOUT 85.70 TG 83.82 INV DOWNSPOUT DOWNSPOUT DOWNSPOUTDOWNSPOUT 385.00 TG 82.97 INVPIPE = 1%2 PI P E = 1 % 85.85HP/FL 1% 1% PI P E = 1 % 85.70 TG 84.23 INV 1 2 5% SLOPE 2% 2% 85.85HP/FL 1% 1% 5% 5% 5% DATE: P.M.: DRAWN BY: JOB NO.: 26081 Merit Cir, STE 111 Laguna Hills, CA 92653 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. D ES I GNBUILDCNI 7/ 2 / 2 0 2 5 1 0 : 2 9 : 4 9 A M G1.0 B.N. F.M. DRIANGE PLAN 07.11.24 2024001108 UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT  VICINITY MAP W BISHOP ST W BISHOP ST S R O S S S T S P A R T O N S T RICHLAND ST RICHLAND ST S V A N N E S S S T REV DATE REMARKS 07/02/2025 S Van Ness Ave Address: 606 S Van Ness Ave, Santa Ana, CA 92701 Unit 2 Project Engineer: M. Jalalpour Approved by: F. Rezaeian Page 1 of 213 07/15/2025 EXP. 06-30-2026 S Van Ness Ave 1. Description of the Structure and Site ................................................................................................. 3 2. Design Criteria ................................................................................................................................... 3 2.1 Design Codes and Standards ........................................................................................................... 3 3. Loading .............................................................................................................................................. 4 3.1 Gravity Loading ............................................................................................................................... 4 3.1.1 Dead Load ................................................................................................................................. 4 3.1.2 Live Load .................................................................................................................................. 4 3.2 Lateral Load ..................................................................................................................................... 5 3.2.1 Seismic Load ............................................................................................................................ 5 3.2.2 Wind Load ................................................................................................................................ 8 4. Wood Design ......................................................................................................................................... 9 4.1 Shear Wall Design ........................................................................................................................... 9 4.2 Diaphragm Design ......................................................................................................................... 11 4.2.1 Diaphragm Seismic Force ....................................................................................................... 11 4.2.2 Collector Design ..................................................................................................................... 12 4.2.3 Chord Design .......................................................................................................................... 13 4.3 Beam and Post Design ................................................................................................................... 15 4.4 Header, Jack Stud and King Stud Design ...................................................................................... 15 4.5 Joist Design .................................................................................................................................... 15 4.6 Stud Wall Design ........................................................................................................................... 15 5. Foundation Design ............................................................................................................................... 16 Appendix A : County Of Orange Report .......................................................................................... 18 Appendix B : ASCE 7 Hazard Report .............................................................................................. 22 Appendix C : Wind Load ................................................................................................................. 25 Appendix D : Shear Wall Design ..................................................................................................... 32 Appendix E : Beam and Post Design ............................................................................................... 81 Appendix F : Header, Jack and King Stud Design ........................................................................ .120 Append ix G : Joist Design ................................................................................................................149 Appendix H : Stud Wall Design ...................................................................................................... 164 Appendix I : Foundation Design .....................................................................................................167 Table of Contents Page 2 of 213 S Van Ness Ave 1. Description of the Structure and Site This project is located at 606 S Van Ness Ave, Santa Ana, CA 92701, is a new one-story residential building. The north elevation of structure is shown in Fig.1. The structural system consists of wood structural frame system with shear wall. No geotechnical report was provided. The design of foundation is based on the default value provided in foundation requirements for residential projects and accessory structures dated 06/22/2020 by the County of Orange Department of Public Works. The design of foundation is also based on the default values provided in Table 1806.2 of CBC 2022 for soil class 5 (CL, ML, MH, and CH). For more information see Appendix A. 2. Design Criteria 2.1 Design Codes and Standards For design purposes, the following codes, standards, and local regulations are used:  California Building Standards Code, (CBC-2022)  Minimum Design Loads for Buildings and Other Structures, (ASCE/SEI 7 -16)  Building Code Requirements for Structural Concrete and Commentary, (ACI318–19)  National Design Specification for Wood Construction, (NDS-2018)  Special Design Provisions for Wind and Seismic, (SDPWS-2021)  Braced Wall Section of CRC for Wind and Seismic at Acceptable Lines. Figure 1. The North Elevation of Structure EXISTING HOUSE Page 3 of 213 S Van Ness Ave 3. Loading 3.1 Gravity Loading 3.1.1 Dead Load The dead loads are tabulated in Table 1. Table 1. Dead Loads Name Value Unit Ceiling 6 psf Roof 12 psf Exterior Wall (for Stucco) 17 psf Interior Wall 10 psf Partition 5 psf 3.1.2 Live Load Live loads are tabulated in Table 2. Table 2. Live Loads Name Value Unit Roof 16 psf Ceiling 20 psf Page 4 of 213 S Van Ness Ave 3.2 Lateral Load ASCE 7 hazard report is given in Appendix B. 3.2.1 Seismic Load The wood seismic parameters are tabulated in Table 3. S1 0.461 Mapped acceleration parameters Ss 1.29 TL 8 Site Class D(Default) Occupancy Category II Height of Building (feet) 13.08 Importance Factor (Ie) 1 Overstrength Factor, Ω0 3 Table 12.2-1 Deflection Amplification Factor, Cd 4 Table 12.2-1 Response Modification Coefficient 6.5 Table 12.2-1 Building Period Parameter Ct 0.02 Table 12.8-2 Building Period Parameter x 0.75 Table 12.8-2 Site Coefficient at Short Period (Fa) 1.2 (Table 11.4-1) Site Coefficient at 1 Sec Period (Fv) 1.839 (Table 11.4-2) Ta 0.138 Section 12.8.2 SMS 1.548 Section 11.4.4, Eq. (11.4-1) SM1 0.848 Section 11.4.4, Eq. (11.4-2) SDS 1.032 Section 11.4.5, Eq. (11.4-3) SD1 0.565 Section 11.4.5, Eq. (11.4-4) T0 0.109 Section 11.4.6 Ts 0.547 Section 11.4.6 Seismic Design Category Based on Short-Period Response Acceleration Parameter D Table 11.6.1 Seismic Design Category Based on 1-s Period Response Acceleration Parameter D Table 11.6.2 Cs 0.159 Eq. (12.8-2). Cs 0.945 Eq. (12.8-3) & Eq. (12.8-4) Cs(min) 0.045 Eq. (12.8-5). Cs(min) 0 Eq. (12.8-6). Seismic Response Coefficient Cs 0.159 Table 3. Seismic Parametres Page 5 of 213 S Van Ness Ave Design response spectrum is tabulated in Table 4 and it is shown in Fig.2. Table 4. Design Response Spectrum 0 0.413 0.109 1.032 0.8205 1.032 1.22 0.695 2.14 0.396 2.85 0.297 4.27 0.198 8 0.071 8.5 0.063 3.2.1.1 Effective Seismic Weight The effective seismic weight is tabulated in Table 5 . Story Type A (sf) Value (psf) Seismic Weight(lb) Roof Roof 962.445 12 11549 Ceiling 729.752 6 4379 Exterior Wall 454.32 17 7723 Exterior Wall 165.075 17 2806 Partition 364.876 5 1824 Total Seismic Weight (lb) 28281 0 0.2 0.4 0.6 0.8 1 1.2 0 2 4 6 8 10Sp e c t r a l R e s p o n s e Ac c e l e r a t i o n , S a ( g ) Period, T (sec) Design Response Spectrum Page 6 of 213 S Van Ness Ave 3.2.1.2 Base Shear The base shear is calculated according to the following equations: Cs = 0.159 Seismic Weight = 28281 lb Base Shear = Cs × W = 0.159 × 28281 = 4497 lb = 4.5 kips 3.2.1.3 Horizontal Distribution of Seismic Load Horizontal distribution of seismic load is tabulated in Table 6. Story Line A AT A/AT Base Shear Shear Line Force ρF 0.7×ρF sft sft - lb lb lb lb Roof A 129.934 962.45 0.135 4497 607 607 424.9 B 245.852 0.255 1147 1147 802.9 C 360.642 0.375 1686 1686 1180.2 D 226.33 0.235 1057 1057 739.9 3 481.223 0.5 2249 2249 1574.3 Table 6. Horizontal Distribution of Seismic Load Page 7 of 213 S Van Ness Ave 3.2.2 Wind Load The wind load is given in Appendix C. 3.2.2.1 Horizontal Distribution of Wind Load Horizontal distribution of wind load is tabulated in Table 7. Table 7. Horizontal Distribution of Wind Load Line A AT A/AT Base Shear Shear Line Forces sft sft - lb lb A 129.934 962.45 0.135 4700 635 B 245.852 0.255 1199 C 360.642 0.375 1763 D 226.33 0.235 1105 3 481.223 0.5 5600 2800 Page 8 of 213 S Van Ness Ave 4. Wood Design 4.1 Shear Wall Design Shear wall design is given in Appendix D. The location of shear walls are shown in Figs 3 and 4. Figure 3. The Location of CLG Plan Shear Walls TEMP. GLASS KITCHEN LIVING ROOM MASTER BEDROOM BATH DINING ROOM LANDING CLOSET ENTRY ATTIC ACCESS SW1 (13'-10") SW1 (8'-2") SW1 (2'-8") C44 HDU 2 HDU 2 C44HDU 2 WS P (1 7 ' - 3 " ) WS P (2 5 ' - 9 " ) SW 1 (1 3 ' - 0 " ) C44 C44 HDU 2 C44 HDU 2 C44 HDU 2 C44 C44 C44HDU 2 HDU 2 C44 HDU 2 HDU 2 C44HDU 2 HDU 2 C44C44HDU 2 1 A B C D 2 3 4 SW1 (8'-6") Page 9 of 213 S Van Ness Ave Figure 4. The Location of Roof Plan Shear Walls TEMP. GLASS KITCHEN LIVING ROOM MASTER BEDROOM BATH DINING ROOM CLOSET ENTRY ATTIC ACCESS SW1 (13'-10") SW1 (8'-2") SW1 (2'-8") SW 1 (1 3 ' - 0 " ) C44 WS P (1 7 ' - 3 " ) WS P (2 5 ' - 9 " ) C44 C44 C44 C44 C44C44 C44 C44 C44 1 A B C D 2 3 4 C44 C44 SW1 (8'-6") C44 MST48 MST48 MST48MST48 Page 10 of 213 S Van Ness Ave 4.2 Diaphragm Design 4.2.1 Diaphragm Seismic Force 4.2.1.1 Horizontal Distribution of Diaphragm Seismic Force The horizontal distribution of diaphragm seismic force is tabulated in Table 8. Table 8. Horizontal Distribution of Diaphragm Seismic Force Line A AT A/AT Fpx Fpx (min) Fpx (max) Shear Line Forces ASD Diaphragm Forces sft sft - lb lb lb lb lb A 129.9 962.45 0.135 4497 5837 11674 788 552 B 245.9 0.255 1488 1042 C 360.6 0.375 2189 1532 D 226.3 0.235 1372 960 3 481.2 0.5 2919 2043 Page 11 of 213 S Van Ness Ave 4.2.2 Collector Design The location of collector for one and two shear walls are shown in Fig 5. The collector force is tabulated in Table 9. Table 9. Collector Force for One Shear Wall Line Line Length Shear Line Forces Shear Line Forces Drag Left Drag Right lb plf lb lb A 22.8 552 24.21 487 0 B 31 1042 33.613 766 0 C 31 1532 49.7 0 -1109 D 31 960 30.968 260 -273 3 25.7 1680 65.37 778 0 Figure 5. Location of Collector For One Shear Wall Page 12 of 213 S Van Ness Ave 4.2.3 Chord Design Chord-X: Chord-Y: M=WL2/8=14169.15 ft-lbs T=C=14169.15/33= 429.37 lbs W=4086/27.75=147.2 plf M=WL2/8=6434.63 ft-lbs T=C=6434.63/27.75 = 231.88 lbs W=1560/33=47.27 plf Page 13 of 213 S Van Ness Ave 2x4 D.F No2 ft=575 psi CD (seismic) = 1.6 CM = 1.0 Ct = 1.0 CF(Ft) = 1.0 Ci=0.8 Ag= 5.25 in2 ft′=ft × CD × CM × Ct × Cf × Ci =763 psi Ft= 736 psi×5.25 in2= 3864 lb fc=1350 psi CD (seismic) = 1.6 CM = 1.0 Ct = 1.0 CF(Ft) = 1.0 Ci=0.8 Ag= 5.25 in2 fc′=fc × CD × CM × Ct × Cf × Ci × Cp =1728 psi Fc= 1728 psi×5.25 in2= 9072 lb Page 14 of 213 S Van Ness Ave 4.3 Beam and Post Design Beam and post design is given in Appendix E. 4.4 Header, Jack Stud and King Stud Design Header, jack stud and king stud design is given in Appendix F. 4.5 Joist Design Joist design is given in Appendix G. 4.6 Stud Wall Design Stud wall design is given in Appendix H. The location of elements are shown in Figs 6 and 7. Figure 6. The Location of CLG Plan Elements Page 15 of 213 LANDING HDR-5 CJ-2 CJ-6 CJ-5 CJ-3 CB - 1 C-6 CB - 2 CB - 3 CB-4 CB - 5 CB - 6 CB-7 CB-8 HDR-1 HDR-3 HDR-1 HDR-6HDR-7 HDR-2 HD R - 4 HD R - 8 HD R - 9 HDR-10 C-9 C-10 C-11 C-12 C-13 C-14 C-15 C-16 C-17 C-18C-19 CB - 9 CJ-5 CJ-7 CB - 1 0 CB-11 CB-11 HD R HDR HDR CJ-4 CJ-1 CJ-6 CJ-1 1 A B C D 2 3 4 CJ-8 CJ-9 CB - 1 3 CB-12 CJ-6 HD R C-9 S Van Ness Ave 5. Foundation Design The foundation design is given in Appendix I. Allowable bearing capacity for the design of foundations = 1500 psf Figure 7. The Location of Roof Plan Elements TEMP. GLASS KITCHEN LIVING ROOM MASTER BEDROOM BATH DINING ROOM CLOSET ENTRY ATTIC ACCESS RR-5 RR-4 RR-3 RR-4RR-1 RR-2 RR-1 RB - 1 RB - 2 HIP B E A M - 1 HIP B E A M - 2 HIP B E A M - 1 HIP B E A M - 1 RB-3 C-1 C-2 C-3 C-4 C-5 C-1 C-1 C-6 C-7 C-8 C-8 HIP B E A M - 3 RR-5 RR-3 RR-5 1 A B C D 2 3 4 HIP B E A M - 3 Page 16 of 213 S Van Ness Ave Limitations BN performed the structural design in a manner consistent with the level of skill and care ordinarily exercised by professional engineers and consultants practicing under similar conditions. No other representation, warranty, or guarantee is given. Provided opinions are based on our engineering judgment. We will not be responsible for latent defects that may appear in the future or for different opinions of others that may arise. The design is performed considering available information for the structure. Should additional information become available that we are not aware of, or which is unknown at the time of our analysis, we reserve the right to revise our design as needed and additional costs may be required. Page 17 of 213 S Van Ness Ave Appendix A : County Of Orange Report Page 18 of 213 EFFECTIVE DATE: June 22, 2020 BACKGROUND: 1.Section R401.4 of 2019 California Residential Code (CRC) requires a soils test to determine the soil's characteristics if expansive soils are likely to be present. 2.Section 1803.5.11 of 2019 California Building Code (CBC) requires a "geotechnical investigationH for any structure determined to be in Seismic Design Category C, D, E or Fin accordance with Section 1613. 3.Exception to Section 1803.2 states, "The building official shall be permitted to waive the requirement for a geotechnical investigation where satisfactory data from adjacent areas is available that demonstrates an investigation is not necessary for any of the conditions in Sections 1803.5.1 through 1803.5.6 and Sections 1803.5.10 and 1803.5.11." POLICY: Since majority of the County of Orange is located in Seismic Design Category D and due to the presence of expansive soil in some county areas, we have developed the following policy to' comply with the 2019 CRC and CBC. Geotechnical investigation report is required for all projects except as prescribed below. Exception: L One story room addition(s) to a single family dwelling up to 1,200 square feet of individual areas if it is NOT located in liquefaction area. 2.One story room addition(s) to a single family dwelling up to 500 square feet of individual areas if It � located in liquefaction area. 3.(a) Room addition(s) to a single family dwelling larger than 500 square feet of individual areas but not more than 1,200 square feet located in liquefaction area shall require 4' of overexcavation. (b)Detached accessory structure or single family dwelling larger than 500 square feet but not more than 1,200 square feet located in liquefaction area shall require 4' overexcavation. 4.One story detached accessory structure up to 1,200 square feet located in non-liquefaction area. One story detached accessory structure up to 500 square feet located in liquefaction area. 5.Second story addition above existing first floor within the footprint of existing dwelling. Excepted projects as described in item 5 above shall provide a letter from a California Licensed Geotechnical Engineer or Civil Engineer practicing soil engineering stating the condition of existing foundation and supporting Foundation Requirements for Residential Projects and Accessory Structures 601 N. Ross Street, Santa Ana, CA 92701 P.O. Box 4048, Santa Ana, CA 92702-4048 www.ocpublicworks.com 714.667.8888 | myOCeServices.ocgov.com Page 19 of 213 subgrade soils and providing foundation recommendations due to the added vertical and lateral loads from the proposed second story addition. Excepted projects as described above item 1 through 4 shall follow the alternate method as outlined below in lieu of geotechnical investigation report provided minimum foundation clearance from slope is maintained based on Section 1808.7 or R403.1.7 or County of Orange Grading Code, whichever is more restrictive: A.For slab on grade construction •Scarify top 12" or recompact 4' overexcavation prior to trenching for the utility and/or foundation. 90% compaction report is required at the time of foundation inspection. Damp proofing, base course and pre-saturation are required. •Provide 5" slab on grade reinforced with #4 at 18" on centers each way over 4" base of ½" or larger clean aggregate with 10 mil vapor retarder in direct contact with concrete. Slab shall be tied-in to continuous 12" wide X 24" (minimum embedment into firm soil) foundation. •Continuous foundation must be reinforced with 2 #5 (or 3 #4) top and bottom. See attached slab on grade foundation detail 'A' for additional information. 8.For raised foundation construction: •Provide continuous foundation with 12" wide X 24" (minimum embedment Into firm soll) around the perimeter of the addition. •Continuous foundation must be reinforced with 2 #5 (or 3 #4) top and bottom. •Provide 18" (minimum embedment) for all interior pier footing. See attached raised floor foundation detail 'B' for additional information. Note: All concrete shall be fc'=4,500 psi (minimum) with type V cement maximum water cement ratio of 0.45. No special Inspection required if concrete truck mix ticket is provided. This policy does not apply to projects that require grading plans and permit per County Grading Code. Approved by: Rya[se,f� Engineering Geologist Hadl Tabatabaee, P.E., CBO, CASp County Building Official 6-15-2020 601 N. Ross Street, Santa Ana, CA 92701 P.O. Box 4048, Santa Ana, CA 92702-4048 www.ocpublicworks.com 714.667.8888 | myOCeServices.ocgov.com Foundation Requirements for Residential Projects and Accessory Structures Page 20 of 213 Foundation Details 601 N. Ross Street, Santa Ana, CA 92701 P.O. Box 4048, Santa Ana, CA 92702-4048 www.ocpublicworks.com 714.667.8888 | myOCeServices.ocgov.com 10 MIL (MIN) POLYETHYLENE Page 21 of 213 S Van Ness Ave Appendix B : ASCE 7 Hazard Report Page 22 of 213 ASCE Hazards Report Address: 606 S Van Ness Ave Santa Ana, California 92701 Standard:ASCE/SEI 7-16 Latitude:33.739154 Risk Category:II Longitude:-117.873649 Soil Class:D - Default (see Section 11.4.3) Elevation:92.19962137230381 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Mon Dec 09 2024 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Page 23 of 213 SS : 1.29 S1 : 0.461 F a : 1.2 F v : N/A SMS : 1.549 SM1 : N/A SDS : 1.032 SD1 : N/A T L : 8 PGA : 0.546 PGA M : 0.655 F PGA : 1.2 Ie : 1 C v : 1.358 Seismic Site Soil Class: Results: Data Accessed: Date Source: D - Default (see Section 11.4.3) USGS Seismic Design Maps Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Mon Dec 09 2024 Page 24 of 213 S Van Ness Ave Appendix C : Wind Load Page 25 of 213 sazan Project 606 SOUTH VAN NESS AVE- SANTA ANA Job Ref. Section Sheet no./rev. 1 Calc. by M.A Date 12/17/2024 Chk'd by Date App'd by Date WIND LOADING In accordance with ASCE7-16 Using the directional design method Tedds calculation version 2.1.13 Building data Type of roof;Gable Length of building ;b = 27.75 ft Width of building ;d = 33.00 ft Height to eaves;H = 8.00 ft Pitch of roof;0 = 17.3 deg Mean height;h = 10.57 ft General wind load requirements Basic wind speed;V = 95.0 mph Risk category;II Velocity pressure exponent coef (Table 26.6-1);Kd = 0.85 Ground elevation above sea level ;zgl = 0 ft Ground elevation factor ;Ke = exp(-0.0000362  zgl/1ft) = 1.00 Exposure category (cl 26.7.3);B Enclosure classification (cl.26.12);Enclosed buildings Internal pressure coef +ve (Table 26.13-1);GCpi_p = 0.18 Internal pressure coef –ve (Table 26.13-1);GCpi_n = -0.18 Gust effect factor;Gf = 0.85 Minimum design wind loading (cl.27.1.5);pmin_r = 8 lb/ft2 Topography Topography factor not significant ;Kzt = 1.0 Velocity pressure equation ;q = 0.00256  Kz  Kzt  Kd  V2  1psf/mph2; Page 26 of 213 sazan Project 606 SOUTH VAN NESS AVE- SANTA ANA Job Ref. Section Sheet no./rev. 2 Calc. by M.A Date 12/17/2024 Chk'd by Date App'd by Date Velocity pressures table z (ft)Kz (Table 26.10-1)qz (psf) 8.00 0.57 11.19 10.57 0.57 11.19 13.14 0.57 11.19 Peak velocity pressure for internal pressure Peak velocity pressure – internal (as roof press.);qi = 11.19 psf Pressures and forces Net pressure;p = q  Gf  Cpe - qi  GCpi; Net force;Fw = p  Aref; Roof load case 1 - Wind 0, GC pi 0.18, -cpe Zone Ref. height (ft) Ext pressure coefficient cpe Peak velocity pressure qp (psf) Net pressure p (psf) Area Aref (ft2) Net force Fw (kips) A (-ve)10.57 -0.45 11.19 -6.31 479.57 -3.03 B (-ve)10.57 -0.55 11.19 -7.21 479.57 -3.46 Total vertical net force ;Fw,v = -6.19 kips Total horizontal net force ;Fw,h = 0.13 kips Walls load case 1 - Wind 0, GC pi 0.18, -cpe Zone Ref. height (ft) Ext pressure coefficient cpe Peak velocity pressure qp (psf) Net pressure p (psf) Area Aref (ft2) Net force Fw (kips) A 8.00 0.80 11.19 5.60 222.00 1.24 B 10.57 -0.46 11.19 -6.41 222.00 -1.42 C 10.57 -0.70 11.19 -8.68 348.80 -3.03 D 10.57 -0.70 11.19 -8.68 348.80 -3.03 Overall loading Projected vertical plan area of wall ;Avert_w_0 = b  H = 222.00 ft2 Projected vertical area of roof ;Avert_r_0 = b  d/2  tan(0) = 142.61 ft2 Minimum overall horizontal loading ;Fw,total_min = pmin_w  Avert_w_0 + pmin_r  Avert_r_0 = 4.69 kips Leeward net force;Fl = Fw,wB = -1.4 kips Windward net force ;Fw = Fw,wA = 1.2 kips Overall horizontal loading ;Fw,total = max(Fw - Fl + Fw,h, Fw,total_min) = 4.7 kips Roof load case 2 - Wind 0, GC pi -0.18, -0cpe Zone Ref. height (ft) Ext pressure coefficient cpe Peak velocity pressure qp (psf) Net pressure p (psf) Area Aref (ft2) Net force Fw (kips) A (+ve)10.57 0.04 11.19 2.38 479.57 1.14 B (+ve)10.57 -0.55 11.19 -3.18 479.57 -1.53 Total vertical net force ;Fw,v = -0.36 kips Total horizontal net force ;Fw,h = 0.79 kips Page 27 of 213 sazan Project 606 SOUTH VAN NESS AVE- SANTA ANA Job Ref. Section Sheet no./rev. 3 Calc. by M.A Date 12/17/2024 Chk'd by Date App'd by Date Walls load case 2 - Wind 0, GC pi -0.18, -0cpe Zone Ref. height (ft) Ext pressure coefficient cpe Peak velocity pressure qp (psf) Net pressure p (psf) Area Aref (ft2) Net force Fw (kips) A 8.00 0.80 11.19 9.63 222.00 2.14 B 10.57 -0.46 11.19 -2.38 222.00 -0.53 C 10.57 -0.70 11.19 -4.65 348.80 -1.62 D 10.57 -0.70 11.19 -4.65 348.80 -1.62 Overall loading Projected vertical plan area of wall ;Avert_w_0 = b  H = 222.00 ft2 Projected vertical area of roof ;Avert_r_0 = b  d/2  tan(0) = 142.61 ft2 Minimum overall horizontal loading ;Fw,total_min = pmin_w  Avert_w_0 + pmin_r  Avert_r_0 = 4.69 kips Leeward net force;Fl = Fw,wB = -0.5 kips Windward net force ;Fw = Fw,wA = 2.1 kips Overall horizontal loading ;Fw,total = max(Fw - Fl + Fw,h, Fw,total_min) = 4.7 kips Roof load case 3 - Wind 90, GC pi 0.18, -cpe Zone Ref. height (ft) Ext pressure coefficient cpe Peak velocity pressure qp (psf) Net pressure p (psf) Area Aref (ft2) Net force Fw (kips) A (-ve)10.57 -0.90 11.19 -10.58 182.66 -1.93 B (-ve)10.57 -0.90 11.19 -10.58 182.66 -1.93 C (-ve)10.57 -0.50 11.19 -6.77 365.32 -2.47 D (-ve)10.57 -0.30 11.19 -4.87 228.49 -1.11 Total vertical net force ;Fw,v = -7.11 kips Total horizontal net force ;Fw,h = 0.00 kips Walls load case 3 - Wind 90, GC pi 0.18, -cpe Zone Ref. height (ft) Ext pressure coefficient cpe Peak velocity pressure qp (psf) Net pressure p (psf) Area Aref (ft2) Net force Fw (kips) A 13.14 0.80 11.19 5.60 348.81 1.95 B 10.57 -0.50 11.19 -6.77 348.80 -2.36 C 10.57 -0.70 11.19 -8.68 222.00 -1.93 D 10.57 -0.70 11.19 -8.68 222.00 -1.93 Overall loading Projected vertical plan area of wall ;Avert_w_90 = d  H + d2  tan(0) / 4 = 348.80 ft2 Projected vertical area of roof ;Avert_r_90 = 0.00 ft2 Minimum overall horizontal loading ;Fw,total_min = pmin_w  Avert_w_90 + pmin_r  Avert_r_90 = 5.58 kips Leeward net force;Fl = Fw,wB = -2.4 kips Windward net force ;Fw = Fw,wA = 2.0 kips Overall horizontal loading ;Fw,total = max(Fw - Fl + Fw,h, Fw,total_min) = 5.6 kips Page 28 of 213 sazan Project 606 SOUTH VAN NESS AVE- SANTA ANA Job Ref. Section Sheet no./rev. 4 Calc. by M.A Date 12/17/2024 Chk'd by Date App'd by Date Roof load case 4 - Wind 90, GC pi -0.18, +cpe Zone Ref. height (ft) Ext pressure coefficient cpe Peak velocity pressure qp (psf) Net pressure p (psf) Area Aref (ft2) Net force Fw (kips) A (+ve)10.57 -0.18 11.19 0.30 182.66 0.06 B (+ve)10.57 -0.18 11.19 0.30 182.66 0.06 C (+ve)10.57 -0.18 11.19 0.30 365.32 0.11 D (+ve)10.57 -0.18 11.19 0.30 228.49 0.07 Total vertical net force ;Fw,v = 0.28 kips Total horizontal net force ;Fw,h = 0.00 kips Walls load case 4 - Wind 90, GC pi -0.18, +cpe Zone Ref. height (ft) Ext pressure coefficient cpe Peak velocity pressure qp (psf) Net pressure p (psf) Area Aref (ft2) Net force Fw (kips) A 13.14 0.80 11.19 9.63 348.81 3.36 B 10.57 -0.50 11.19 -2.74 348.80 -0.96 C 10.57 -0.70 11.19 -4.65 222.00 -1.03 D 10.57 -0.70 11.19 -4.65 222.00 -1.03 Overall loading Projected vertical plan area of wall ;Avert_w_90 = d  H + d2  tan(0) / 4 = 348.80 ft2 Projected vertical area of roof ;Avert_r_90 = 0.00 ft2 Minimum overall horizontal loading ;Fw,total_min = pmin_w  Avert_w_90 + pmin_r  Avert_r_90 = 5.58 kips Leeward net force;Fl = Fw,wB = -1.0 kips Windward net force ;Fw = Fw,wA = 3.4 kips Overall horizontal loading ;Fw,total = max(Fw - Fl + Fw,h, Fw,total_min) = 5.6 kips Page 29 of 213 sazan Project 606 SOUTH VAN NESS AVE- SANTA ANA Job Ref. Section Sheet no./rev. 5 Calc. by M.A Date 12/17/2024 Chk'd by Date App'd by Date Page 30 of 213 sazan Project 606 SOUTH VAN NESS AVE- SANTA ANA Job Ref. Section Sheet no./rev. 6 Calc. by M.A Date 12/17/2024 Chk'd by Date App'd by Date Page 31 of 213 S Van Ness Ave Appendix D : Shear Wall Design Page 32 of 213 STORY 1 APA W a ll Bra cing Ca lculator Project Report Builder/Designer Home/Building Plan Name Development Address 606 Code BAS ED ON 2021 IRC S DC (Seismic Design Category)D2 Wind Speed <= 95 mph Wind Exposure Category EXPOS URE B Total Number of Stories 1 S TORY Cripple Wall NO Mean Roof Height less than 30 ft.YES Designer Responsibilities: C heck irregularities per IRC section R301.2.2.6 C onfirm load path to foundation per IRC section R403.1.6 Design foundations per IRC section R403.1 Include interior braced wall line foundations per IRC Section R602.11 Design cripple walls in one of two way s Redesignate as the first story and use the calculator Design by hand per IRC Section R602.10.10. 1 4 Page 33 of 213 B1 B1 W ALL LINE ELEVATION VIEW To tal Wa ll Line Le ngth: 25' 9" W ALL LINE PLAN VIEW Sto r y Wa ll Line Br a c ing Me tho d Wind F a c to r s Wind Br a c ing Amount Se ismic F a c to r s Se ismic Br a cing A m o unt Re quir e d Bra c ing Qua lif ie d Br a cing Br a cing Sta tus 1st St ory WSP 0.93 2.65 1.59 9.94 9.94 25.75 Compliant F ur the s t Dista nce to Adj a ce nt BWL 22' 4"Stone or Ma s o nr y Ve ne e r Omitted Ro o f Ea v e to Ridge He ight 5 feet Wa ll De a d Lo a d > 8 psf but <= 15 psf Wa ll Line Le ngth 25' 9"Ro o f/Ce iling De a d Loa ds 18 ps f Gy ps um Omitted Blo ck ing Included Wa ll Line Se gm e nt Wa ll He ight Sto r y He ight Br a c ing Me tho d Se g m e nt Le ngth A dj a c e nt Ope ning He ight Qua lifie d Se gme nt Na ils T e nsion T ie Ho ld Do wn B1 8'9'WSP 25' 9"25.75 6"/12" 1 Page 34 of 213 B1 B1 W ALL LINE ELEVATION VIEW To tal Wa ll Line Le ngth: 17' 3" W ALL LINE PLAN VIEW Sto r y Wa ll Line Br a c ing Me tho d Wind F a c to r s Wind Br a c ing Amount Se ismic F a c to r s Se ismic Br a cing A m o unt Re quir e d Bra c ing Qua lif ie d Br a cing Br a cing Sta tus 1st St ory WSP 0.93 1.23 1.59 6.76 6.76 17.25 Compliant F ur the s t Dista nce to Adj a ce nt BWL 8' 2"Stone or Ma s o nr y Ve ne e r Omitted Ro o f Ea v e to Ridge He ight 5 feet Wa ll De a d Lo a d > 8 psf but <= 15 psf Wa ll Line Le ngth 17' 3"Ro o f/Ce iling De a d Loa ds 18 ps f Gy ps um Omitted Blo ck ing Included Wa ll Line Se gm e nt Wa ll He ight Sto r y He ight Br a c ing Me tho d Se g m e nt Le ngth A dj a c e nt Ope ning He ight Qua lifie d Se gme nt Na ils T e nsion T ie Ho ld Do wn B1 8'9'WSP 17' 3"17.25 6"/12" 4 Page 35 of 213 W ALL LINE ELEVATION VIEW Tota l Wall Line Length: 0' 0" W ALL LINE PLAN VIEW Sto r y Wa ll Line Bra c ing Me thod Wind F a c to r s Wind Br a c ing A m o unt Se ismic F a c to r s Se is m ic Br a c ing Amount Re quir e d Bra c ing Qua lifie d Bra c ing Br a c ing Sta tus 1st St ory 1 Not Possible Not Possible Not Possible Not Possible Not Possible 0 Not Compliant F ur the s t Dista nce to Adj a ce nt BWL Ro o f Ea v e to Ridge He ight Wa ll Line Le ngth Gy ps um Blo ck ing Wa ll Line Se gme nt Wa ll He ight Story He ig ht Bra c ing Me thod Se gm e nt Le ng th A dja c e nt Ope ning He ight Qua lif ie d Se gm e nt Na ils T e nsion T ie Ho ld Down Page 36 of 213 W ALL LINE ELEVATION VIEW Tota l Wall Line Length: 0' 0" W ALL LINE PLAN VIEW Sto r y Wa ll Line Br a cing Me tho d Wind F a cto r s Wind Br a cing A m o unt Se is m ic F a cto r s Se ismic Br a cing A m o unt Re quir e d Br a c ing Qua lifie d Br a c ing Br a c ing Sta tus 1st St ory 2 Not Possible N/A Not Possible N/A N/A 0 Non Compliant F ur the s t Dista nce to Adj a ce nt BWL Ro o f Ea v e to Ridge He ight Wa ll Line Le ngth Gy ps um Blo ck ing Wa ll Line Se gme nt Wa ll He ight Story He ig ht Bra c ing Me thod Se gm e nt Le ng th A dja c e nt Ope ning He ight Qua lif ie d Se gm e nt Na ils T e nsion T ie Ho ld Down Page 37 of 213 APA W all Bracing C alc ulator v 2.7.0 A PA Mak es No W arranties o f A ny Kind A ll info rmatio n in the Tool is prov ided "as is", with no guarantee o f completeness, accuracy , timeliness o r of the results obtained fro m the use o f this information, and witho ut w arranty o f any k ind, express o r implied, including, but not limited to w arranties of performance, merchantability and fitness fo r a particular purpo se.Yo u can find the full terms and conditio ns fo r use here: file:///C :/inetpub/w w w ro o t/A PA W ood_2017/apa-w all-bracing-calculato r-disclaimer Page 38 of 213 Sazan 606 1 LINE 3 R1 Sazan Inc 2024-17-12 DR.Jalilpour 2024-17-12 DR.Rezaeian 2024-17-12 Wood shear wall design (NDS) In accordance with NDS2018 allowable stress design and the Perforated shear wall method Design summary Shear capacity for wind loading Vw 3.64 ( ratio =0.46 ) OK Shear capacity for seismic loading Vs 2.6 ( ratio =0.61 ) OK Design tensile stress (Ch1) ft' 1380 ( ratio =0.06 ) OK Design compressive stress (Ch1) fc' 596.16 ( ratio =0.24 ) OK Design tensile stress (Ch2) ft' 1380 ( ratio =0.06 ) OK Design compressive stress (Ch2) fc' 596.16 ( ratio =0.24 ) OK bearing compr. stress, bottom plate fc-perp' 625 ( ratio =0.23 ) OK Hold Down resistance 3000 ( ratio =0.28 ) OK Shear wall deflection δsww 0.097 ( ratio =0.36 ) OK Panel details Structural I wood panel sheathing on One side Panel height H = 8ft Panel length B = 13ft Total area of wall A = H x B = 104ft2 Total area of Opening =104 -(4×3)=12ft2 Panel construction Nominal stud size 2 "x4" Dressed stud size 1.5"x3.5" Cross-sectional area of studs As= 5.25 in 2 Stud spacing s = 16 in Nominal end post size 1x4 "x4" Dressed end post size 3.5 "x3.5" Cross-sectional area of end posts Ae= 12.25 in 2 Hole diameter Dia = 0.625 in Page 39 of 213 Net cross-sectional area of end posts Aen= 10.06 in 2 Effective length for chord forces Beff= 12.56 ft Service condition Dry Temperature 10 0 degF or less Anchor offset e=0 in Anchor Location Inside face Hold Down HDU2 Vertical anchor stiffness Ka = 34091 lb/in From NDS Supplement Table 4A - Reference design values for visually graded dimension lumber Species, grade and size classification Douglas Fir-Larch, No.2 grade, 2'' & wider Specific gravity G = 0.5 Tension parallel to grain F t=575 lb/in2 Compression parallel to grain Fc=1350 lb/in2 Compression perpendicular to grain F c_perp=625 lb/in2 Modulus of elasticity E=1600000 lb/in 2 Minimum modulus of elasticity Emin=580000 lb/in2 Sheathing details Sheathing material 15/32'' wood panel structural I 3 -ply plywood sheathing Fastener type 10d Common nail at 6"centers Shear capacity adjustment factor (eqn. 4.3 -6) Co=0.896551724137931 From SDPWS Table 4.3A Nominal Unit Shear Capacities f or Wood-Frame Shear Walls - Wood-based Panels Nominal unit shear capacity V n =950×0.92 =874 plf Apparent shear wall shear stiffness G a=16 kips/in Loading details Dead load acting on top of panel DL = 93.6 lb/ft Floor live load acting on top of panel LL = 88 lb/ft Roof live load acting on top of panel Lr = 89.6 lb/ft Self weight of panel Swt = 17 lb/ft 2 In plane wind load acting at head of panel WL = 2800 lbs Snow load acting on top of panel SL = 0 lb/ft Rain load acting on top of panel RL = 0 lb/ft Wind load serviceability factor fwserv = 0.45 In plane seismic load acting at head of panel Eq = 2249 lbs Design spectral response accel. par., short periods S DS ==1.032 Page 40 of 213 Deflection ampification factor Cdδ = 4 Seismic importance factor Ie = 1 Chord Wind Sisemic Dead,comp Dead,Tens Live LiveRoof Snow Rain Ch1 0 0 0 0 0 0 0 0 Ch2 0 0 0 0 0 0 0 0 From ASCE 7-16 - cl.2.4.1 and cl. 2.4.5 Basic combinations Load combination no.1 D + 0.6W Load combination no.2 D + 0.7E Load combination no.3 D + 0.75Lf + 0.45W + 0.75(Lr or S or R) Load combination no.4 D + 0.75Lf + 0.525E + 0.75S Load combination no.5 0.6D + 0.6W Load combination no.6 0.6D + 0.7E Adjustment factors Load duration factor – Table 2.3.2 CD=1.6 Size factor for tension – Table 4A CFt=1.5 Size factor for compression – Table 4A CFc=1.15 Wet service factor for tension – Table 4A CMt=1 Wet service factor for compression – Table 4A CMc=1 Wet service factor for modulus of elasticity – Table 4A CME=1 Temperature factor for tension – Table 2.3.3 Ctt=1 Temperature factor for compression – Table 2.3.3 Ctc=1 Temperature factor for modulus of elasticity – Table 2.3.3 CtE=1 Incising factor – cl.4.3.8 C i=1 Buckling stiffness factor – cl.4.4.2 CT=1 Bearing area factor - cl. 3.10.4 C b=1 For sawn lumber c=0.8 Adjusted modulus of elasticity E min' = Emin× CME× CtE× Ci× CT=580000 psi Critical buckling design value F cE = 0.822×Emin' /(h/d)2= 633.71 psi Reference compression design value F c* = Fc× CD× CMc× Ctc× CFc× Ci=2484 psi Column stability factor – eqn.3.7-1 Cp = (1+(FcE/Fc*))/(2×c)-√([(1+(FcE/Fc*))/(2*c)]2-(FcE/Fc*)/c)= 0.24 From SDPWS Table 4.3.4 Maximum Shear Wall Aspect Ratios Maximum shear wall aspect ratio 3.5 Shear wall length B = 13 ft H = 8 ft Page 41 of 213 Length Type H/B Concept 6.9 Wall 1.16 ShearWall 3 Opening 3.1 Wall 2.58 ShearWall Shear capacity adjustment factor – cl.4.3.5.6 Sum of perforated shear wall segment lengths ∑bi=9.3 ft Total area of wall A=104 ft 2 Total full height sheathed area A fhs=80 ft2 Shear capacity adjustment factor (eqn. 4.3 -6) Co = min(Awall/(3×Ao + Afhs), 1.0)= 0.896551724137931 Perforated shear wall capacity Maximum shear force under wind loading V w_max=0.6×W/1000 =1.68 Kips Shear capacity for wind loading V w=(Vn×CO*∑bi/2000) =3.64 Kips ratio V w-max / Vw =0.46 PASS - Shear capacity for wind load exceeds maximum shear force Maximum shear force under seismic loading V s_max=0.7×Eq/1000 =1.574 Kips Shear capacity for seismic loading V s=(Vn×CO*∑bi/(2.8×1000)) =2.6 Kips ratio V s_max / Vs =0.61 PASS - Shear capacity for seismic load exceeds maximum shear force Chord capacity for chord1 Load Combination : 0.6DL - 0.7EQ Maximum tensile force in chord T=830.68 lb Maximum applied tensile stress f t=T/Aen=82.57 lb/in2 Design tensile stress ft*=Ft×CD×CMt×Ctt×CFt×Ci=1380 lb/in2 82.57/1380+0.06 PASS - Design tensile stress exceeds maximum applied tensile stress Load Combination : DL + 0.6WL Maximum compressive force in chord P=1764.98 lb Maximum applied compressive stress f c=P/Ae=144.08 lb/in2 Design compressive stress f c*=Fc×CD×CMc×Ctc×CFc×Ci×Cp=596.16 lb/in2 144.08/596.16=0.24 PASS - Design compressive stress exceeds maximum applied tensile stress Chord capacity for chord2 Load Combination : 0.6DL - 0.7EQ Maximum tensile force in chord T=830.68 lb Page 42 of 213 Maximum applied tensile stress ft=T/Aen=82.57 lb/in2 Design tensile stress f t*=Ft×CD×CMt×Ctt×CFt×Ci=1380 lb/in2 82.57/1380=0.06 PASS - Design tensile stress exceeds maximum applied te nsile stress Load Combination : DL + 0.6WL Maximum compressive force in chord P=1764.98 lb Maximum applied compressive stress f c=P/Ae=144.08 lb/in2 Design compressive stress f c*=Fc×CD×CMc×Ctc×CFc×Ci×Cp=596.16 lb/in2 144.08/596.16=0.24 PASS - Design compressive stress exceeds maximum applied tensile stress bearing compr. stress, bottom plate For (maximum compressive force) fc-perp*=Fc-perp×CMc×Ctc×Cb×Ci=625 lb/in2 144.08/625=0.23 PASS - bearing compr. stress, bottom plate Hold down force Chord1 T1=0.83 Kips Chord2 T2=0.83 Kips Wind load deflection Design shear force V δw=FWserv×W=1.26kips Deflection limit Δw_allow=H×12/360= 0.267 in Induced unit shear v δW=VδW/(CO×∑bi)/Cu=151.12lb/ft Anchor tension force Tδ = max(0 ,(v δW /1000)×H×B/Beff- 0.6×(D + Swt×H)×B/2000 - 0.6*min((DT-ch1)/1000,(DT- ch2)/1000) + 0.45×max(abs(W-ch1)/1000, abs(W-ch2)/1000))= 0.31 kips Chord compression force Cδ = max(0,(vδW/1000)×H×B/Beff+0.6×(D+Swt×H)×B/2000 + 0.6×max((Dc -ch1)/1000,(Dc- ch2)/1000) + 0.45×ma x(abs(W-ch1)/1000, abs(W-ch2)/1000))= 2.1 kips Vertical elongation at anchor ∆T = Tδ×1000/Ka= 0.009 in Vertical compression at chord ∆C = 0.04×Cδ*1000/(Ae×Fc -perp)= 0.011 in Total vertical deflection ∆a=(∆T+∆C)×(B/Beff)= 0.021 in Shear wall deflection δsww =2×(vδW/12000)×((H×12)^3)/(3×(E/1000)×Ae×∑bi×12)+(vδW/12000)×H×12/(Ga)+ H×12×∆a /(∑bi×12) = 0.097 in 0.1/0.27=0.36 PASS - Shear wall deflection is less than deflection limit Seismic deflection Design shear force V δs=Eq/1000= 2.25 kips Deflection limit Δ s_allow=0.025×H×12= 2.4 in Induced unit shear v δs=Vδs/CO×∑bi/Cub=269.85 lb/ft Page 43 of 213 Anchor tension force Tδ = max(0,(vδs/1000)*H*B/Beff-(0.6-0.2*SDS)*(DL+ Swt*H)*B/2000 -(0.6-0.2*SDS )* min((DT-ch1)/1000, (DT-ch2)/1000)+max(abs(Eq-ch1)/1000, abs(Eq-ch2)/1000))= 1.57 kips Chord compression force Cδ = max(0,(vδs/1000)*H*B/Beff+(0.6- 0.2*SDS)*(DL+Swt*H)*B/2000 + (0.6-0.2*SDS )* max((Dc-ch1)/1000, (Dc-ch2)/1000)+max(abs(Eq-ch1)/1000, abs(Eq- ch2)/1000))= 2.75 kips Vertical elongation at anchor ∆T = Tδ× 1000/Ka= 0.046 in Vertical compression at chord ∆C = 0.04×Cδ*1000/(Ae×Fc -perp)= 0.014 in Total vertical deflection ∆a=(∆T+∆C)×(B/Beff)= 0.062 in Shear wall elastic deflection δswse =2×(vδs/12000)×((H×12)^3)/(3×(E/1000)×Ae×∑bi×12)+(vδss/12000)×H×12/(Ga)+ H×12×∆a /(∑bi×12) = 0.194 in Amp. seis. deflection δsws = Cdδ*δswse /Ie = 0.776 in 0.78/2.4=0.32 PASS - Shear wall deflection is less than deflection limit Page 44 of 213 Collector seismic design force factor F Coll=1 Maximum shear force on wall V max= max(FColl×Vs_max, Vw_max) =1.68kips Maximum force in collector Pcoll=0.417kips Maximum applied tensile stress ft= Tcoll/(1×As) =59.57lb/in2 Design tensile stress Ft'= Ft×CD×CMt×Ctt×CFt×Ci = 1380lb/in2 ft/Ft' =0.04 PASS - Design tensile stress exceeds maximum applied tensile stress Maximum applied compressive stress fc= Pcoll/(1×As) =59.57lb/in2 Column stability factor C P= 1.00 Design tensile stress Fc'=Fc×CD×CMc×Ctc×CFc×Ci×CP = 2484lb/in2 fc/Fc' =0.02 PASS - Design compressive stress exceeds maximum applied compressive stress Page 45 of 213 Sazan 606 1 LINE A-LOWER R1 Sazan Inc 2024-17-12 DR.Jalalpour 2024-17-12 DR.Razaeian 2024-17-12 Wood shear wall design (NDS) In accordance with NDS2018 allowable stress design and the segmented shear wall method Design summary Shear wall aspect ratio H/B 2.96 OK Shear capacity for seismic loading Vs 0.74 ( ratio =0.57 ) OK Design tensile stress (Ch1) ft' 1380 ( ratio =0.13 ) OK Design compressive stress (Ch1) fc' 596.16 ( ratio =0.28 ) OK Design tensile stress (Ch2) ft' 1380 ( ratio =0.13 ) OK Design compressive stress (Ch2) fc' 596.16 ( ratio =0.28 ) OK bearing compr. stress, bottom plate fc-perp' 625 ( ratio =0.27 ) OK Hold Down resistance 3000 ( ratio =0.6 ) OK Shear wall deflection δsww 0.21 ( ratio =0.79 ) OK Panel details Structural I wood panel sheathing on One side Panel height H = 8ft Panel length B = 2.7ft Total area of wall A = H x B = 21.6ft2 Panel construction Nominal stud size 2 "x4" Dressed stud size 1.5 "x3.5" Cross-sectional area of studs As= 5.25 in 2 Stud spacing s = 16 in Nominal end post size 1x4 "x4" Dressed end post size 3.5 "x3.5" Cross-sectional area of end posts Ae= 12.25 in 2 Hole diameter Dia = 0.625 in Net cross-sectional area of end posts Aen= 10.06 in 2 Page 46 of 213 Effective length for chord forces Beff= 2.26 ft Service condition Dry Temperature 100 degF or less Anchor offset e=0 in Anchor Location Inside face Hold Down HDU2 Vertical anchor stiffness Ka = 34091 lb/in From NDS Supplement Table 4A - Reference design values for visually graded dimension lumber Species, grade and size classification Douglas Fir-Larch, No.2 grade, 2'' & wider Specific gravity G = 0.5 Tension parallel to grain F t=575 lb/in2 Compression parallel to grain F c=1350 lb/in2 Compression perpendicular to grain F c_perp=625 lb/in2 Modulus of elasticity E=1600000 lb/in 2 Minimum modulus of elasticity E min=580000 lb/in2 Sheathing details Sheathing material 15/32'' wood panel structural I 3-ply plywood sheathing Fastener type 10d Common nail at 6"centers From SDPWS Table 4.3A Nominal Unit Shear Capacities for Wood-Frame Shear Walls - Wood-based Panels Nominal unit shear capacity V n =950×0.92×(1.25-0.125H/B) =768.8 plf Apparent shear wall shear stiffness Ga=16 kips/in Loading details Dead load acting on top of panel DL = 58.25 lb/ft Floor live load acting on top of panel LL = 13.3 lb/ft Roof live load acting on top of panel Lr = 21.3 lb/ft Self weight of panel Swt = 17 lb/ft 2 In plane wind load acting at head of panel WL = 635 lbs Snow load acting on top of panel SL = 0 lb/ft Rain load acting on top of panel RL = 0 lb/ft Wind load serviceability factor fwserv = 0.45 In plane seismic load acting at head of panel Eq = 607 lbs Design spectral response accel. par., short periods S DS ==1.032 Deflection ampification factor Cdδ = 4 Seismic importance factor Ie = 1 Page 47 of 213 Chord Wind Sisemic Dead,comp Dead,Tens Live LiveRoof Snow Rain Ch1 -632.2 -604.3 0 0 0 0 0 0 Ch2 632.2 604.3 0 0 0 0 0 0 From ASCE 7-16 - cl.2.4.1 and cl. 2.4.5 Basic combinations Load combination no.1 D + 0.6W Load combination no.2 D + 0.7E Load combination no.3 D + 0.75Lf + 0.45W + 0.75(Lr or S or R) Load combination no.4 D + 0.75Lf + 0.525E + 0.75S Load combination no.5 0.6D + 0.6W Load combination no.6 0.6D + 0.7E Adjustment factors Load duration factor – Table 2.3.2 CD=1.6 Size factor for tension – Table 4A CFt=1.5 Size factor for compression – Table 4A CFc=1.15 Wet service factor for tension – Table 4A CMt=1 Wet service factor for compression – Table 4A CMc=1 Wet service factor for modulus of elasticity – Table 4A CME=1 Temperature factor for tension – Table 2.3.3 Ctt=1 Temperature factor for compression – Table 2.3.3 Ctc=1 Temperature factor for modulus of elasticity – Table 2.3.3 CtE=1 Incising factor – cl.4.3.8 C i=1 Buckling stiffness factor – cl.4.4.2 CT=1 Bearing area factor - cl. 3.10.4 C b=1 For sawn lumber c=0.8 Adjusted modulus of elasticity E min' = Emin× CME× CtE× Ci× CT=580000 psi Critical buckling design value F cE = 0.822×Emin' /(h/d)2= 633.71 psi Reference compression design value F c* = Fc× CD× CMc× Ctc× CFc× Ci=2484 psi Column stability factor – eqn.3.7-1 Cp = (1+(FcE/Fc*))/(2×c)-√([(1+(FcE/Fc*))/(2*c)]2-(FcE/Fc*)/c)= 0.24 From SDPWS Table 4.3.4 Maximum Shear Wall Aspect Ratios Maximum shear wall aspect ratio 3.5 Shear wall length B = 2.7 ft H = 8 ft Shear wall aspect ratio H / B = 2.96 PASS- Maximum shear wall aspect ratio Segmented shear wall capacity Page 48 of 213 Maximum shear force under wind loading V w_max=0.6×W/1000 =0.38 Kips Shear capacity for wind loading V w=(Vn×B/2000) =1.04 Kips ratio V w-max / Vw =0.37 PASS - Shear capacity for wind load exceeds maximum shear force Maximum shear force under seismic loading V s_max=0.7×Eq/1000 =0.42 Kips Shear capacity for seismic loading V s=(Vn×B/(2.8×1000)) =0.74 Kips ratio V s_max / Vs =0.57 PASS - Shear capacity for seismic load exceeds maximum shear force Chord capacity for chord1 Load Combination : 0.6DL - 0.7EQ Maximum tensile force in chord T=1807.63 lb Maximum applied tensile stress f t=T/Aen=179.68 lb/in2 Design tensile stress f t*=Ft×CD×CMt×Ctt×CFt×Ci=1380 lb/in2 179.68/1380=0.13 PASS - Design tensile stress exceeds maximum applied tensile stress Load Combination : DL + 0.7EQ Maximum compressive force in chord P=2075.29 lb Maximum applied compressive stress f c=P/Ae=169.41 lb/in2 Design compressive stress f c*=Fc×CD×CMc×Ctc×CFc×Ci×Cp=596.16 lb/in2 169.41/596.16=0.28 PASS - Design compressive stress exceeds maximum applied tensile stress Chord capacity for chord2 Load Combination : 0.6DL - 0.7EQ Maximum tensile force in chord T=1807.63 lb Maximum applied tensile stress f t=T/Aen=179.68 lb/in2 Design tensile stress ft*=Ft×CD×CMt×Ctt×CFt×Ci=1380 lb/in2 179.68/1380=0.13 PASS - Design tensile stress exceeds maximum applied tensile stress Load Combination : DL + 0.7EQ Maximum compressive force in chord P=2075.29 lb Maximum applied compressive stress f c=P/Ae=169.41 lb/in2 Design compressive stress f c*=Fc×CD×CMc×Ctc×CFc×Ci×Cp=596.16 lb/in2 169.41/596.16=0.28 PASS - Design compressive stress exceeds maximum applied tensile stress bearing compr. stress, bottom plate For (maximum compressive force) fc-perp*=Fc-perp×CMc×Ctc×Cb×Ci=625 lb/in2 169.41/625=0.27 PASS - bearing compr. stress, bottom plate Hold down force Page 49 of 213 Chord1 T1=1.81 Kips Chord2 T2=1.81 Kips Wind load deflection Design shear force V δw=FWserv×W=0.29kips Deflection limit Δ w_allow=H×12/360= 0.267 in Induced unit shear v δW=VδW/B/Cub=107.41lb/ft Anchor tension force Tδ = max(0 ,(v δW /1000)×H×B/Beff- 0.6×(D + Swt×H)×B/2000 - 0.6*min((DT-ch1)/1000,(DT- ch2)/1000) + 0.45×max(abs(W-ch1)/1000, abs(W-ch2)/1000))= 1.15 kips Chord compression force Cδ = max(0,(vδW/1000)×H×B/Beff+0.6×(D+Swt×H)×B/2000 + 0.6×max((Dc -ch1)/1000,(Dc- ch2)/1000) + 0.45×max(abs(W-ch1)/1000, abs(W-ch2)/1000))= 1.47 kips Vertical elongation at anchor ∆T = Tδ×1000/Ka= 0.034 in Vertical compression at chord ∆C = 0.04×Cδ*1000/(Ae×Fc -perp)= 0.008 in Total vertical deflection ∆a=(∆T+∆C)×(B/Beff)= 0.05 in Shear wall deflection δsww =2×(vδW/12000)×((H×12)^3)/(3×(E/1000)×Ae×B×12)+(vδW/12000)×H×12/(Ga)+ H×12×∆a /(B×12) = 0 .21 in 0.21/0.27=0.79 PASS - Shear wall deflection is less than deflection limit Seismic deflection Design shear force V δs=Eq/1000= 0.61 kips Deflection limit Δ s_allow=0.025×H×12= 2.4 in Induced unit shear v δs=Vδs/B/Cub=225.93 lb/ft Anchor tension force Tδ = max(0,(vδs/1000)*H*B/Beff-(0.6-0.2*SDS)*(DL+ Swt*H)*B/2000 -(0.6-0.2*SDS )* min((DT-ch1)/1000, (DT-ch2)/1000)+max(abs(Eq-ch1)/1000, abs(Eq-ch2)/1000))= 2.66 kips Chord compression force Cδ = m ax(0,(vδs/1000)*H*B/Beff+(0.6- 0.2*SDS)*(DL+Swt*H)*B/2000 + (0.6-0.2*SDS )* max((Dc-ch1)/1000, (Dc-ch2)/1000)+max(abs(Eq-ch1)/1000, abs(Eq- ch2)/1000))= 2.87 kips Vertical elongation at anchor ∆T = Tδ×1000/Ka= 0.078 in Vertical compression at chord ∆C = 0.04×Cδ*1000/(Ae×Fc -perp)= 0.015 in Total vertical deflection ∆a=(∆T+∆C)×(B/Beff)= 0.111 in Shear wall elastic deflection δswse =2×(vδs/12000)×((H×12)^3)/(3×(E/1000)×Ae×B×12)+(vδss/12000)×H×12/(Ga)+ H×12×∆a /(B×12) = 0.459 in Amp. seis. deflection δsws = Cdδ*δswse /Ie = 1.836 in 1.84/2.4=0.76 PASS - Shear wall deflection is less than deflection limit Page 50 of 213 Sazan 606 1 LINE A-UPPER R1 Sazan Inc 2024-17-12 DR.Jalalpour 2024-17-12 DR.Razaeian 2024-17-12 Wood shear wall design (NDS) In accordance with NDS2018 allowable stress design and the segmented shear wall method Design summary Shear wall aspect ratio H/B 0.83 OK Shear capacity for seismic loading Vs 0.84 ( ratio =0.5 ) OK Design tensile stress (Ch1) ft' 1380 ( ratio =0.02 ) OK Design compressive stress (Ch1) fc' 2310.12 ( ratio =0.02 ) OK Design tensile stress (Ch2) ft' 1380 ( ratio =0.02 ) OK Design compressive stress (Ch2) fc' 2310.12 ( ratio =0.02 ) OK bearing compr. stress, bottom plate fc-perp' 625 ( ratio =0.06 ) OK Hold Down resistance 3950 ( ratio =0.1 ) OK Amp. seis. deflection δsws 0.372 ( ratio =0.55 ) OK Panel details Structural I wood panel sheathing on One side Panel height H = 2.25ft Panel length B = 2.7ft Total area of wall A = H x B = 6.075ft2 Panel construction Nominal stud size 2 "x4" Dressed stud size 1.5 "x3.5" Cross-sectional area of studs As= 5.25 in 2 Stud spacing s = 16 in Nominal end post size 1x4 "x4" Dressed end post size 3.5 "x3.5" Cross-sectional area of end posts Ae= 12.25 in 2 Hole diameter Dia = 0 in Net cross-sectional area of end posts Aen= 12.25 in 2 Page 51 of 213 Effective length for chord forces Beff= 2.26 ft Service condition Dry Temperature 100 degF or less Anchor offset e=0 in Anchor Location Inside face Hold Down MST48 Vertical anchor stiffness Ka = 10000 lb/in From NDS Supplement Table 4A - Reference design values for visually graded dimension lumber Species, grade and size classification Douglas Fir-Larch, No.2 grade, 2'' & wider Specific gravity G = 0.5 Tension parallel to grain F t=575 lb/in2 Compression parallel to grain F c=1350 lb/in2 Compression perpendicular to grain F c_perp=625 lb/in2 Modulus of elasticity E=1600000 lb/in 2 Minimum modulus of elasticity E min=580000 lb/in2 Sheathing details Sheathing material 15/32'' wood panel structural I 3-ply plywood sheathing Fastener type 10d Common nail at 6"centers From SDPWS Table 4.3A Nominal Unit Shear Capacities for Wood-Frame Shear Walls - Wood-based Panels Nominal unit shear capacity V n =950×0.92 =874 plf Apparent shear wall shear stiffness G a=16 kips/in Loading details Dead load acting on top of panel DL = 20 lb/ft Floor live load acting on top of panel LL = 13.3 lb/ft Roof live load acting on top of panel Lr = 21.3 lb/ft Self weight of panel Swt = 17 lb/ft 2 In plane wind load acting at head of panel WL = 635 lbs Snow load acting on top of panel SL = 0 lb/ft Rain load acting on top of panel RL = 0 lb/ft Wind load serviceability factor fwserv = 0.45 In plane seismic load acting at head of panel Eq = 607 lbs Design spectral response accel. par., short periods S DS ==1.032 Deflection ampification factor Cdδ = 4 Seismic importance factor Ie = 1 Page 52 of 213 Chord Wind Sisemic Dead,comp Dead,Tens Live LiveRoof Snow Rain Ch1 0 0 0 0 0 0 0 0 Ch2 0 0 0 0 0 0 0 0 From ASCE 7-16 - cl.2.4.1 and cl. 2.4.5 Basic combinations Load combination no.1 D + 0.6W Load combination no.2 D + 0.7E Load combination no.3 D + 0.75Lf + 0.45W + 0.75(Lr or S or R) Load combination no.4 D + 0.75Lf + 0.525E + 0.75S Load combination no.5 0.6D + 0.6W Load combination no.6 0.6D + 0.7E Adjustment factors Load duration factor – Table 2.3.2 CD=1.6 Size factor for tension – Table 4A CFt=1.5 Size factor for compression – Table 4A CFc=1.15 Wet service factor for tension – Table 4A CMt=1 Wet service factor for compression – Table 4A CMc=1 Wet service factor for modulus of elasticity – Table 4A CME=1 Temperature factor for tension – Table 2.3.3 Ctt=1 Temperature factor for compression – Table 2.3.3 Ctc=1 Temperature factor for modulus of elasticity – Table 2.3.3 CtE=1 Incising factor – cl.4.3.8 C i=1 Buckling stiffness factor – cl.4.4.2 CT=1 Bearing area factor - cl. 3.10.4 C b=1 For sawn lumber c=0.8 Adjusted modulus of elasticity E min' = Emin× CME× CtE× Ci× CT=580000 psi Critical buckling design value F cE = 0.822×Emin' /(h/d)2= 8011.4 psi Reference compression design value F c* = Fc× CD× CMc× Ctc× CFc× Ci=2484 psi Column stability factor – eqn.3.7-1 Cp = (1+(FcE/Fc*))/(2×c)-√([(1+(FcE/Fc*))/(2*c)]2-(FcE/Fc*)/c)= 0.93 From SDPWS Table 4.3.4 Maximum Shear Wall Aspect Ratios Maximum shear wall aspect ratio 3.5 Shear wall length B = 2.7 ft H = 2.25 ft Shear wall aspect ratio H / B = 0.83 PASS- Maximum shear wall aspect ratio Segmented shear wall capacity Page 53 of 213 Maximum shear force under wind loading V w_max=0.6×W/1000 =0.38 Kips Shear capacity for wind loading V w=(Vn×B/2000) =1.18 Kips ratio V w-max / Vw =0.32 PASS - Shear capacity for wind load exceeds maximum shear force Maximum shear force under seismic loading V s_max=0.7×Eq/1000 =0.42 Kips Shear capacity for seismic loading V s=(Vn×B/(2.8×1000)) =0.84 Kips ratio V s_max / Vs =0.5 PASS - Shear capacity for seismic load exceeds maximum shear force Chord capacity for chord1 Load Combination : 0.6DL - 0.7EQ Maximum tensile force in chord T=387.2 lb Maximum applied tensile stress f t=T/Aen=31.61 lb/in2 Design tensile stress f t*=Ft×CD×CMt×Ctt×CFt×Ci=1380 lb/in2 31.61/1380=0.02 PASS - Design tensile stress exceeds maximum applied tensile stress Load Combination : DL + 0.7EQ Maximum compressive force in chord P=467.46 lb Maximum applied compressive stress f c=P/Ae=38.16 lb/in2 Design compressive stress f c*=Fc×CD×CMc×Ctc×CFc×Ci×Cp=2310.12 lb/in2 38.16/2310.12=0.02 PASS - Design compressive stress exceeds maximum applied tensile stress Chord capacity for chord2 Load Combination : 0.6DL - 0.7EQ Maximum tensile force in chord T=387.2 lb Maximum applied tensile stress f t=T/Aen=31.61 lb/in2 Design tensile stress ft*=Ft×CD×CMt×Ctt×CFt×Ci=1380 lb/in2 31.61/1380=0.02 PASS - Design tensile stress exceeds maximum applied tensile stress Load Combination : DL + 0.7EQ Maximum compressive force in chord P=467.46 lb Maximum applied compressive stress f c=P/Ae=38.16 lb/in2 Design compressive stress f c*=Fc×CD×CMc×Ctc×CFc×Ci×Cp=2310.12 lb/in2 38.16/2310.12=0.02 PASS - Design compressive stress exceeds maximum applied tensile stress bearing compr. stress, bottom plate For (maximum compressive force) fc-perp*=Fc-perp×CMc×Ctc×Cb×Ci=625 lb/in2 38.16/625=0.06 PASS - bearing compr. stress, bottom plate Hold down force Page 54 of 213 Chord1 T1=0.39 Kips Chord2 T2=0.39 Kips Wind load deflection Design shear force V δw=FWserv×W=0.29kips Deflection limit Δ w_allow=H×12/360= 0.075 in Induced unit shear v δW=VδW/B/Cub=107.41lb/ft Anchor tension force Tδ = max(0 ,(v δW /1000)×H×B/Beff- 0.6×(D + Swt×H)×B/2000 - 0.6*min((DT-ch1)/1000,(DT- ch2)/1000) + 0.45×max(abs(W-ch1)/1000, abs(W-ch2)/1000))= 0.24 kips Chord compression force Cδ = max(0,(vδW/1000)×H×B/Beff+0.6×(D+Swt×H)×B/2000 + 0.6×max((Dc -ch1)/1000,(Dc- ch2)/1000) + 0.45×max(abs(W-ch1)/1000, abs(W-ch2)/1000))= 0.34 kips Vertical elongation at anchor ∆T = Tδ×1000/Ka= 0.024 in Vertical compression at chord ∆C = 0.04×Cδ*1000/(Ae×Fc -perp)= 0.002 in Total vertical deflection ∆a=(∆T+∆C)×(B/Beff)= 0.031 in Shear wall deflection δsww =2×(vδW/12000)×((H×12)^3)/(3×(E/1000)×Ae×B×12)+(vδW/12000)×H×12/(Ga)+ H×12×∆a /(B×12) = 0.041 in 0.04/0.08=0.55 PASS - Shear wall deflection is less than deflection limit Seismic deflection Design shear force V δs=Eq/1000= 0.61 kips Deflection limit Δ s_allow=0.025×H×12= 0.675 in Induced unit shear v δs=Vδs/B/Cub=225.93 lb/ft Anchor tension force Tδ = max(0,(vδs/1000)*H*B/Beff-(0.6-0.2*SDS)*(DL+ Swt*H)*B/2000 -(0.6-0.2*SDS )* min((DT-ch1)/1000, (DT-ch2)/1000)+max(abs(Eq-ch1)/1000, abs(Eq-ch2)/1000))= 0.58 kips Chord compression force Cδ = max(0,(vδs/1000)*H*B/Beff+(0.6- 0.2*SDS)*(DL+Swt*H)*B/2000 + (0.6-0.2*SDS )* max((Dc-ch1)/1000, (Dc-ch2)/1000)+max(abs(Eq-ch1)/1000, abs(Eq- ch2)/1000))= 0.64 kips Vertical elongation at anchor ∆T = Tδ×1000/Ka= 0.058 in Vertical compression at chord ∆C = 0.04×Cδ*1000/(Ae×Fc -perp)= 0.003 in Total vertical deflection ∆a=(∆T+∆C)×(B/Beff)= 0.073 in Shear wall elastic deflection δswse =2×(vδs/12000)×((H×12)^3)/(3×(E/1000)×Ae×B×12)+(vδss/12000)×H×12/(Ga)+ H×12×∆a /(B×12) = 0.093 in Amp. seis. deflection δsws = Cdδ*δswse /Ie = 0.372 in 0.37/0.68=0.55 PASS - Shear wall deflection is less than deflection limit Page 55 of 213 Sazan 606 1 LINE B R1 Sazan Inc 2024-17-12 DR.Jalilpour 2024-17-12 DR.Rezaeian 2024-17-12 Wood shear wall design (NDS) In accordance with NDS2018 allowable stress design and the Perforated shear wall method Design summary Shear capacity for wind loading Vw 2.17 ( ratio =0.33 ) OK Shear capacity for seismic loading Vs 1.55 ( ratio =0.52 ) OK Design tensile stress (Ch1) ft' 1380 ( ratio =0.06 ) OK Design compressive stress (Ch1) fc' 596.16 ( ratio =0.2 ) OK Design tensile stress (Ch2) ft' 1380 ( ratio =0.06 ) OK Design compressive stress (Ch2) fc' 596.16 ( ratio =0.2 ) OK bearing compr. stress, bottom plate fc-perp' 625 ( ratio =0.19 ) OK Hold Down resistance 3000 ( ratio =0.3 ) OK Amp. seis. deflection δsws 0.864 ( ratio =0.36 ) OK Panel details Structural I wood panel sheathing on One side Panel height H = 8ft Panel length B = 8.2ft Total area of wall A = H x B = 65.6ft2 Total area of Opening =65.6 -(3×2)=6ft2 Panel construction Nominal stud size 2 "x4" Dressed stud size 1.5"x3.5" Cross-sectional area of studs As= 5.25 in 2 Stud spacing s = 16 in Nominal end post size 1x4 "x4" Dressed end post size 3.5 "x3.5" Cross-sectional area of end posts Ae= 12.25 in 2 Hole diameter Dia = 0.625 in Page 56 of 213 Net cross-sectional area of end posts Aen= 10.06 in 2 Effective length for chord forces Beff= 7.76 ft Service condition Dry Temperature 100 degF or less Anchor offset e=0 in Anchor Location Inside face Hold Down HDU2 Vertical anchor stiffness Ka = 34091 lb/in From NDS Supplement Table 4A - Reference design values for visually graded dimension lumber Species, grade and size classification Douglas Fir-Larch, No.2 grade, 2'' & wider Specific gravity G = 0.5 Tension parallel to grain F t=575 lb/in2 Compression parallel to grain Fc=1350 lb/in2 Compression perpendicular to grain F c_perp=625 lb/in2 Modulus of elasticity E=1600000 lb/in 2 Minimum modulus of elasticity Emin=580000 lb/in2 Sheathing details Sheathing material 15/32'' wood panel structural I 3 -ply plywood sheathing Fastener type 10d Common nail at 6"centers Shear capacity adjustment factor (eqn. 4.3 -6) Co=0.970414201183432 From SDPWS Table 4.3A Nominal Unit Shear Capacities f or Wood-Frame Shear Walls - Wood-based Panels Nominal unit shear capacity V n =950×0.92 =874 plf Apparent shear wall shear stiffness G a=16 kips/in Loading details Dead load acting on top of panel DL = 75.3 lb/ft Floor live load acting on top of panel LL = 57 lb/ft Roof live load acting on top of panel Lr = 77.6 lb/ft Self weight of panel Swt = 17 lb/ft 2 In plane wind load acting at head of panel WL = 1199 lbs Snow load acting on top of panel SL = 0 lb/ft Rain load acting on top of panel RL = 0 lb/ft Wind load serviceability factor fwserv = 0.45 In plane seismic load acting at head of panel Eq = 1147 lbs Design spectral response accel. par., short periods S DS ==1.032 Page 57 of 213 Deflection ampification factor Cdδ = 4 Seismic importance factor Ie = 1 Chord Wind Sisemic Dead,comp Dead,Tens Live LiveRoof Snow Rain Ch1 0 0 0 0 0 0 0 0 Ch2 0 0 0 0 0 0 0 0 From ASCE 7-16 - cl.2.4.1 and cl. 2.4.5 Basic combinations Load combination no.1 D + 0.6W Load combination no.2 D + 0.7E Load combination no.3 D + 0.75Lf + 0.45W + 0.75(Lr or S or R) Load combination no.4 D + 0.75Lf + 0.525E + 0.75S Load combination no.5 0.6D + 0.6W Load combination no.6 0.6D + 0.7E Adjustment factors Load duration factor – Table 2.3.2 CD=1.6 Size factor for tension – Table 4A CFt=1.5 Size factor for compression – Table 4A CFc=1.15 Wet service factor for tension – Table 4A CMt=1 Wet service factor for compression – Table 4A CMc=1 Wet service factor for modulus of elasticity – Table 4A CME=1 Temperature factor for tension – Table 2.3.3 Ctt=1 Temperature factor for compression – Table 2.3.3 Ctc=1 Temperature factor for modulus of elasticity – Table 2.3.3 CtE=1 Incising factor – cl.4.3.8 C i=1 Buckling stiffness factor – cl.4.4.2 CT=1 Bearing area factor - cl. 3.10.4 C b=1 For sawn lumber c=0.8 Adjusted modulus of elasticity E min' = Emin× CME× CtE× Ci× CT=580000 psi Critical buckling design value F cE = 0.822×Emin' /(h/d)2= 633.71 psi Reference compression design value F c* = Fc× CD× CMc× Ctc× CFc× Ci=2484 psi Column stability factor – eqn.3.7-1 Cp = (1+(FcE/Fc*))/(2×c)-√([(1+(FcE/Fc*))/(2*c)]2-(FcE/Fc*)/c)= 0.24 From SDPWS Table 4.3.4 Maximum Shear Wall Aspect Ratios Maximum shear wall aspect ratio 3.5 Shear wall length B = 8.2 ft H = 8 ft Page 58 of 213 Length Type H/B Concept 2.3 Wall 3.48 ShearWall 2 Opening 3.9 Wall 2.05 ShearWall Shear capacity adjustment factor – cl.4.3.5.6 Sum of perforated shear wall segment lengths ∑bi=5.12 ft Total area of wall A=65.6 ft 2 Total full height sheathed area A fhs=49.6 ft2 Shear capacity adjustment factor (eqn. 4.3 -6) Co = min(Awall/(3×Ao + Afhs), 1.0)= 0.970414201183432 Perforated shear wall capacity Maximum shear force under wind loading V w_max=0.6×W/1000 =0.719 Kips Shear capacity for wind loading V w=(Vn×CO*∑bi/2000) =2.17 Kips ratio Vw-max / Vw =0.33 PASS - Shear capacity for wind load exceeds maximum shear force Maximum shear force under seismic loading V s_max=0.7×Eq/1000 =0.803 Kips Shear capacity for seismic loading V s=(Vn×CO*∑bi/(2.8×1000)) =1.55 Kips ratio V s_max / Vs =0.52 PASS - Shear capacity for seismic load exceeds maximum shear force Chord capacity for chord1 Load Combination : 0.6DL - 0.7EQ Maximum tensile force in chord T=898.15 lb Maximum applied tensile stress f t=T/Aen=89.28 lb/in2 Design tensile stress f t*=Ft×CD×CMt×Ctt×CFt×Ci=1380 lb/in2 89.28/1380+0.06 PASS - Design tensile stress exceeds maximum applied tensile stress Load Combination : DL + 0.7EQ Maximum compressive force in chord P=1454 lb Maximum applied compressive stress f c=P/Ae=118.69 lb/in2 Design compressive stress f c*=Fc×CD×CMc×Ctc×CFc×Ci×Cp=596.16 lb/in2 118.69/596.16=0.2 PASS - Design compressive stress exceeds maximum applied tensile stress Chord capacity for chord2 Load Combination : 0.6DL - 0.7EQ Maximum tensile force in chord T=898.15 lb Page 59 of 213 Maximum applied tensile stress f t=T/Aen=89.28 lb/in2 Design tensile stress f t*=Ft×CD×CMt×Ctt×CFt×Ci=1380 lb/in2 89.28/1380=0.06 PASS - Design tensile stress exceeds maximum applied tensile stress Load Combination : DL + 0.7EQ Maximum compressive force in chord P=1454 lb Maximum applied compressive stress f c=P/Ae=118.69 lb/in2 Design compressive stress f c*=Fc×CD×CMc×Ctc×CFc×Ci×Cp=596.16 lb/in2 118.69/596.16=0.2 PASS - Design compressive stress exceeds maximum applied tensile stress bearing compr. stress, bottom plate For (maxi mum compressive force) fc-perp*=Fc-perp×CMc×Ctc×Cb×Ci=625 lb/in2 118.69/625=0.19 PASS - bearing compr. stress, bottom plate Hold down force Chord1 T1=0.9 Kips Chord2 T2=0.9 Kips Wind load deflection Design shear force V δw=FWserv×W=0.54kips Deflection limit Δw_allow=H×12/360= 0.267 in Induced unit shear v δW=VδW/(CO×∑bi)/Cu=108.68lb/ft Anchor tension force Tδ = max(0 ,(v δW /1000)×H×B/Beff- 0.6×(D + Swt×H)×B/2000 - 0.6*min((DT-ch1)/1000,(DT- ch2)/1000) + 0.45×max(abs(W-ch1)/1000, abs(W-ch2)/1000))= 0.35 kips Chord compression force Cδ = max(0,(vδW/1000)×H×B/Beff+0.6×(D+Swt×H)×B/2000 + 0.6×max((Dc -ch1)/1000,(Dc- ch2)/1000) + 0.45×max(abs(W-ch1)/1000, abs(W-ch2)/1000))= 1.39 kips Vertical elongation at anchor ∆T = Tδ×1000/Ka= 0.01 in Vertical compression at chord ∆C = 0.04×Cδ*1000/(Ae×Fc -perp)= 0.007 in Total vertical deflection ∆a=(∆T+∆C)×(B/Beff)= 0.018 in Shear wall deflection δsww =2×(vδW/12000)×((H×12)^3)/(3×(E/1000)×Ae×∑bi×12)+(vδW/12000)×H×12/(Ga)+ H×12×∆a /(∑bi×12) = 0.087 in 0.09/0.27=0.33 PASS - Shear wall deflection is less than deflection limit Seismic deflection Design shear force V δs=Eq/1000= 1.15 kips Deflection limit Δ s_allow=0.025×H×12= 2.4 in Induced unit shear v δs=Vδs/CO×∑bi/Cub=231.46 lb/ft Page 60 of 213 Anchor tension force Tδ = max(0,(vδs/1000)*H*B/Beff-(0.6-0.2*SDS)*(DL+ Swt*H)*B/2000 -(0.6-0.2*SDS )* min((DT-ch1)/1000, (DT-ch2)/1000)+max(abs(Eq-ch1)/1000, abs(Eq-ch2)/1000))= 1.51 kips Chord compression force Cδ = max(0,(vδs/1000)*H*B/Beff+(0.6- 0.2*SDS)*(DL+Swt*H)*B/2000 + (0.6-0.2*SDS )* max((Dc-ch1)/1000, (Dc-ch2)/1000)+max(abs(Eq-ch1)/1000, abs(Eq- ch2)/1000))= 2.19 kips Vertical elongation at anchor ∆T = Tδ× 1000/Ka= 0.044 in Vertical compression at chord ∆C = 0.04×Cδ*1000/(Ae×Fc -perp)= 0.011 in Total vertical deflection ∆a=(∆T+∆C)×(B/Beff)= 0.058 in Shear wall elastic deflection δswse =2×(vδs/12000)×((H×12)^3)/(3×(E/1000)×Ae×∑bi×12)+(vδss/12000)×H×12/(Ga)+ H×12×∆a /(∑bi×12) = 0.216 in Amp. seis. deflection δsws = Cdδ*δswse /Ie = 0.864 in 0.86/2.4=0.36 PASS - Shear wall deflection is less than deflection limit Page 61 of 213 Collector seismic design force factor F Coll=1 Maximum shear force on wall V max= max(FColl×Vs_max, Vw_max) =0.803kips Maximum force in collector Pcoll=0.203kips Maximum applied tensile stress ft= Tcoll/(1×As) =29lb/in2 Design tensile stress Ft'= Ft×CD×CMt×Ctt×CFt×Ci = 1380lb/in2 ft/Ft' =0.02 PASS - Design tensile stress exceeds maximum applied tensile stress Maximum applied compressive stress fc= Pcoll/(1×As) =29lb/in2 Column stability factor C P= 1.00 Design tensile stress Fc'=Fc×CD×CMc×Ctc×CFc×Ci×CP = 2484lb/in2 fc/Fc' =0.01 PASS - Design compressive stress exceeds maximum applied compressive stress Page 62 of 213 Sazan Project: 606 Job Ref. 1 Shear Wall: line c Sheet no./rev R1 Calc. by Sazan Inc Date 2025-08-07 Chk'd by DR.Jalalpour Date 2025-08-07 App'd by DR.Razaeian Date 2025-08-07 Wood shear wall design (NDS) In accordance with NDS2018 and SDPWS2021 allowable stress design and the segmented shear wall method Design summary Item Parameter Ratio result Shear wall aspect ratio H/B 1.206 OK Shear capacity for seismic loading Vs 0.44 OK Design tensile stress (Ch1) Ft' 0.09 OK Design compressive stress (Ch1) Fc' 0.35 OK Design tensile stress (Ch2) Ft' 0.09 OK Design compressive stress (Ch2) Fc' 0.35 OK bearing compr. stress, bottom plate Fc-perp' 0.21 OK Hold Down resistance HDU2 0.42 OK Amp. seis. deflection δsws 0.29 OK Panel details Structural I wood panel sheathing on One side Panel height H = 10.25ft Panel length B = 8.5ft Total area of wall A = H x B = 87.125ft2 Panel construction Nominal stud size 2 "x4" Dressed stud size 1.5 "x3.5" Cross-sectional area of studs As= 5.25 in 2 Stud spacing s = 16 in Nominal end post size 1x4 "x4" Dressed end post size 3.5 "x3.5" Cross-sectional area of end posts Ae= 12.25 in 2 Hole diameter Dia = 0.62 5 in Net cross-sectional area of end posts Aen= 10.062 in 2 Page 63 of 213 Effective length for chord forces Beff= 8.5 - ((1.5) * 1*3.5) / 12 - 0 / 12=8.062 ft Service condition Dry Temperature 100 degF or less Anchor offset e=0 in Anchor Location Inside face Hold Down HDU2 Vertical anchor stiffness Ka = 34091 lb/in From NDS Supplement Table 4A - Reference design values for visually graded dimension lumber Species, grade and size classification Douglas Fir-Larch, No.2 grade, 2'' & wider Specific gravity G = 0.5 Tension parallel to grain F t=575 lb/in2 Compression parallel to grain F c=1350 lb/in2 Compression perpendicular to grain F c_perp=625 lb/in2 Modulus of elasticity E=1600000 lb/in 2 Minimum modulus of elasticity E min=580000 lb/in2 Sheathing details Sheathing material 15/32'' wood panel Structural I 3-ply plywood sheathing Fastener type 10d Common nails at 6" centers From SDPWS Table 4.3A Nominal Unit Shear Capacities for Wood-Frame Shear Walls - Wood-based Panels Nominal unit shear capacity V n =950×0.92 =874 plf Apparent shear wall shear stiffness G a=16 kips/in Adjustments for Unblocked wood structural panel Unblocked shear wall adjust.factor Cub1 = 1 Loading details Dead load acting on top of panel DL = 24 lb/ft Floor live load acting on top of panel LL = 26.7 lb/ft Roof live load acting on top of panel Lr = 21.3 lb/ft Self weight of panel Swt = 10 lb/ft 2 In plane wind load acting at head of panel WL = 1763 lbs Snow load acting on top of panel SL = 0 lb/ft Rain load acting on top of panel RL = 0 lb/ft Wind load serviceability factor F Wserv= 0.45 In plane seismic load acting at head of panel Eq = 1686 lbs Design spectral response accel. par., short periods S DS =1.032 Page 64 of 213 Deflection amplification factor Cdδ = 4 Seismic importance factor Ie = 1 Chord forces from shear walls above Chord WL(lb) Eq(lb) DLC.(lb) DLT.(lb) LL(lb) Lr(lb) SL(lb) RL(lb) Ch1 0 0 0 0 0 0 0 0 Ch2 0 0 0 0 0 0 0 0 DLC :Compressive Dead point load , DLT :Tensile Dead point load From ASCE 7-16 - cl.2.4.1 and cl. 2.4.5 Basic combinations Load combination no.1 D + 0.6W Load combination no.2 D + 0.7E Load combination no.3 D + 0.75Lf + 0.45W + 0.75(Lr or S or R) Load combination no.4 D + 0.75Lf + 0.525E + 0.75S Load combination no.5 0.6D + 0.6W Load combination no.6 0.6D + 0.7E Adjustment factors Load duration factor – Table 2.3.2 CD=1.6 Size factor for tension – Table 4A CFt=1.5 Size factor for compression – Table 4A C Fc=1.15 Wet service factor for tension – Table 4A CMt=1 Wet service factor for compression – Table 4A CMc=1 Wet service factor for modulus of elasticity – Table 4A CME=1 Temperature factor for tension – Table 2.3.3 Ctt=1 Temperature factor for compression – Table 2.3.3 Ctc=1 Temperature factor for modulus of elasticity – Table 2.3.3 CtE=1 Incising factor – cl.4.3.8 C i=1 Buckling stiffness factor – cl.4.4.2 CT=1 Bearing area factor - cl. 3.10.4 C b=1 For sawn lumber c=0.8 Adjusted modulus of elasticity E min' = Emin× CME× CtE× Ci× CT=580000 psi Critical buckling design value F cE = 0.822×Emin' /(H/d)2= 386.034 psi Reference compression design value F c* = Fc× CD× CMc× Ctc× CFc× Ci=2484 psi Column stability factor – eqn.3.7-1 Cp = (1+(FcE/Fc*))/(2×c)-√([(1+(FcE/Fc*))/(2×c)]2-(FcE/Fc*)/c)= 0.15 From SDPWS Table 4.3.3 Maximum Shear Wall Aspect Ratios Maximum shear wall aspect ratio 3.5 Shear wall length B = 8.5 ft Page 65 of 213 Shear wall height H = 10.25 ft Shear wall aspect ratio H / B = 1.206 Pass - shear wall aspect ratio is less than Maximum shear wall aspect ratio Segmented shear wall capacity Maximum shear force under wind loading Vw_max=0.6×WL/1000 =1.058 Kips Shear capacity for wind loading V w=(Vn×B/2000) =3.714 Kips ratio V w-max / Vw =0.285 PASS - Shear capacity for wind load exceeds maximum shear force Maximum shear force under seismic loading V s_max=0.7×Eq/1000 =1.18 Kips Shear capacity for seismic loading V s=(Vn×B/(2.8×1000)) =2.653 Kips ratio V s_max / Vs =0.445 PASS - Shear capacity for seismic load exceeds maximum shear force Chord capacity for chord1 Load Combination : 0.6DL - 0.7EQ Maximum tensile force in chord T=1255.603 lbs Maximum applied tensile stress ft=T/Aen=124.787 lb/in2 Design tensile stress F t'=Ft×CD×CMt×Ctt×CFt×Ci=1380 lb/in2 Ratio124.79/1380=0.09 PASS - Design tensile stress exceeds maximum applied tensile stress Load Combination : DL + 0.7EQ Maximum compressive force in chord P=1597.02 lbs Maximum applied compressive stress f c=P/Ae=130.369 lb/in2 Design compressive stress Fc'=Fc×CD×CMc×Ctc×CFc×Ci×Cp=372.6 lb/in2 Ratio130.37/372.6=0.35 PASS - Design compressive stress exceeds maximum applied compressive stress Chord capacity for chord2 Load Combination : 0.6DL - 0.7EQ Maximum tensile force in chord T=1255.603 lbs Maximum applied tensile stress f t=T/Aen=124.787 lb/in2 Design tensile stress F t'=Ft×CD×CMt×Ctt×CFt×Ci=1380 lb/in2 Ratio124.79/1380=0.09 PASS - Design tensile stress exceeds maximum applied tensile stress Load Combination : DL + 0.7EQ Maximum compressive force in chord P=1597.02 lbs Page 66 of 213 Maximum applied compressive stress f c=P/Ae=130.369 lb/in2 Design compressive stress F c'=Fc×CD×CMc×Ctc×CFc×Ci×Cp=372.6 lb/in2Ratio130.37/372.6=0.35 PASS - Design compressive stress exceeds maximum applied compressive stress Design bearing compr. stress, bottom plate For maximum compressive force Fc-perp'=Fc-perp×CMc×Ctc×Cb×Ci=625 lb/in2 Ratio130.37/625=0.21 Pass - Design bearing compr. stress, bottom plate exceeds Maximum applied compressive stress Hold down force Chord1 T1=1.256 Kips Chord2 T2=1.256 Kips Wind load deflection Design shear force Vδw=FWserv×WL/1000=0.793kips Deflection limit Δ w_allow=H×12/360= 0.342 in Induced unit shear v δW=(VδW×1000/B)/Cub=93.294 lb/ft Anchor tension force Tδ = max(0 ,(vδW /1000)×H×B/Beff- 0.6×(D + Swt×H)×B/2000 - 0.6×min((DLT- ch1)/1000,(DLT-ch2)/1000) + 0.45×max(abs(W-ch1)/1000, abs(W-ch2)/1000))= 0.686 kips Chord compression force Cδ = max(0,(vδW/1000)×H×B/Beff+0.6×(DL+Swt×H)×B/2000 + 0.6×max((DLC- ch1)/1000,(DLC-ch2)/1000) + 0.45×max(abs(W-ch1)/1000, abs(W-ch2)/1000))= 1.331 kips Vertical elongation at anchor ∆T = Tδ×1000/Ka= 0.02 in Vertical compression at chord ∆C = (0.04 in)×Cδ×1000/(Ae×Fc -perp)= 0.007 in Total vertical deflection ∆a=(∆T+∆C)×(B/Beff)= 0.028 in Shear wall deflection δsww =2×(vδW /12000)×((H×12)^3)/(3×(E/1000)×Ae×B×12)+(vδW /12000)×H×12/(Ga)+ H×12×∆a /(B×12) = 0.098 inRatio0.098/0.342=0.29 PASS - Shear wall deflection is less than deflection limit Seismic deflection redundancy factor ρ=1 Design shear force V δs=(Eq/1000)/ρ= 1.686 kips Deflection limit Δs_allow=0.025×H×12= 3.075 in Induced unit shear v δs=(Vδs×1000/B)/Cub=198.353 lb/ft Anchor tension force Tδ = max(0,(v δs/1000)×H×B/Beff-(0.6-0.2×SDS)×(DL+ Swt×H)×B/2000 -(0.6-0.2×SDS )× min((DLT-ch1)/1000, (DLT-ch2)/1000)+max(abs(Eq-ch1)/1000, abs(Eq-ch2)/1000))= 1.932 kips Chord compression force Cδ = max(0,(vδs/1000)×H×B/Beff+(0.6 - 0.2×SDS)×(DL+Swt×H)×B/2000 + (0.6-0.2×SDS )× max((DLC-ch1)/1000, (DLC-ch2)/1000)+max(abs(Eq-ch1)/1000, abs(Eq-ch2)/1000))= 2.355 kips Page 67 of 213 Vertical elongation at anchor ∆T = Tδ×1000/Ka= 0.057 in Vertical compression at chord ∆C = (0.04 in)×Cδ×1000/(Ae×Fc-perp)= 0.012 in Total vertical deflection ∆a=(∆T+∆C)×(B/Beff)= 0.073 in Shear wall elastic deflection δswse =2×(Vδs/12000)×((H×12)^3)/(3×(E/1000)×Ae×B×12)+(vδs/12000)×H×12/(Ga)+ H×12×∆a /(B×12) = 0.225 in Amp. seis. deflection δsws = Cdδ×δswse /Ie = 0.9 inRatio0.9/3.075=0.29 PASS - Shear wall deflection is less than deflection limit Page 68 of 213 Sazan 606 1 LINE D-LOWER R1 Sazan Inc 2024-17-12 DR.Jalilpour 2024-17-12 DR.Rezaeian 2024-17-12 Wood shear wall design (NDS) In accordance with NDS2018 allowable stress design and the Perforated shear wall method Design summary Shear capacity for wind loading Vw 5.06 ( ratio =0.13 ) OK Shear capacity for seismic loading Vs 3.62 ( ratio =0.2 ) OK Design tensile stress (Ch1) ft' 1380 ( ratio =0 ) OK Design compressive stress (Ch1) fc' 596.16 ( ratio =0.11 ) OK Design tensile stress (Ch2) ft' 1380 ( ratio =0 ) OK Design compressive stress (Ch2) fc' 596.16 ( ratio =0.11 ) OK bearing compr. stress, bottom plate fc-perp' 625 ( ratio =0.1 ) OK Hold Down resistance 3000 ( ratio =0.01 ) OK Amp. seis. deflection δsws 0.244 ( ratio =0.1 ) OK Panel details Structural I wood panel sheathing on One side Panel height H = 8ft Panel length B = 13.8ft Total area of wall A = H x B = 110.4ft2 Total area of Opening =110.4 -(3×2)=6ft2 Panel construction Nominal stud size 2 "x4" Dressed stud size 1.5"x3.5" Cross-sectional area of studs As= 5.25 in 2 Stud spacing s = 16 in Nominal end post size 1x4 "x4" Dressed end post size 3.5 "x3.5" Cross-sectional area of end posts Ae= 12.25 in 2 Hole diameter Dia = 0.625 in Page 69 of 213 Net cross-sectional area of end posts Aen= 10.06 in 2 Effective length for chord forces Beff= 13.36 ft Service condition Dry Temperature 10 0 degF or less Anchor offset e=0 in Anchor Location Inside face Hold Down HDU2 Vertical anchor stiffness Ka = 34091 lb/in From NDS Supplement Table 4A - Reference design values for visually graded dimension lumber Species, grade and size classification Douglas Fir-Larch, No.2 grade, 2'' & wider Specific gravity G = 0.5 Tension parallel to grain F t=575 lb/in2 Compression parallel to grain Fc=1350 lb/in2 Compression perpendicular to grain F c_perp=625 lb/in2 Modulus of elasticity E=1600000 lb/in 2 Minimum modulus of elasticity Emin=580000 lb/in2 Sheathing details Sheathing material 15/32'' wood panel structural I 3 -ply plywood sheathing Fastener type 10d Common nail at 6"centers Shear capacity adjustment factor (eqn. 4.3 -6) Co=0.98220640569395 From SDPWS Table 4.3A Nominal Unit Shear Capacities fo r Wood-Frame Shear Walls - Wood-based Panels Nominal unit shear capacity V n =950×0.92 =874 plf Apparent shear wall shear stiffness G a=16 kips/in Loading details Dead load acting on top of panel DL = 58.25 lb/ft Floor live load acting on top of panel LL = 13.3 lb/ft Roof live load acting on top of panel Lr = 21.3 lb/f t Self weight of panel Swt = 17 lb/ft 2 In plane wind load acting at head of panel WL = 1105 lbs Snow load acting on top of panel SL = 0 lb/ft Rain load acting on top of panel RL = 0 lb/ft Wind load serviceability factor fwserv = 0.45 In plane seismic load acting at head of panel Eq = 1057 lbs Design spectral response accel. par., short periods S DS ==1.032 Page 70 of 213 Deflection ampification factor Cdδ = 4 Seismic importance factor Ie = 1 Chord Wind Sisemic Dead,comp Dead,Tens Live LiveRoof Snow Rain Ch1 -186.1 -178 0 0 0 0 0 0 Ch2 186.1 178 0 0 0 0 0 0 From ASCE 7-16 - cl.2.4.1 and cl. 2.4.5 Basic combinations Load combination no.1 D + 0.6W Load combination no.2 D + 0.7E Load combination no.3 D + 0.75Lf + 0.45W + 0.75(Lr or S or R) Load combination no.4 D + 0.75Lf + 0.525E + 0.75S Load combination no.5 0.6D + 0.6W Load combination no.6 0.6D + 0.7E Adjustment factors Load duration factor – Table 2.3.2 CD=1.6 Size factor for tension – Table 4A CFt=1.5 Size factor for compression – Table 4A CFc=1.15 Wet service factor for tension – Table 4A CMt=1 Wet service factor for compression – Table 4A CMc=1 Wet service factor for modulus of elasticity – Table 4A CME=1 Temperature factor for tension – Table 2.3.3 Ctt=1 Temperature factor for compression – Table 2.3.3 Ctc=1 Temperature factor for modulus of elasticity – Table 2.3.3 CtE=1 Incising factor – cl.4.3.8 C i=1 Buckling stiffness factor – cl.4.4.2 CT=1 Bearing area factor - cl. 3.10.4 C b=1 For sawn lumber c=0.8 Adjusted modulus of elasticity E min' = Emin× CME× CtE× Ci× CT=580000 psi Critical buckling design value F cE = 0.822×Emin' /(h/d)2= 633.71 psi Reference compression design value F c* = Fc× CD× CMc× Ctc× CFc× Ci=2484 psi Column stability factor – eqn.3.7-1 Cp = (1+(FcE/Fc*))/(2×c)-√([(1+(FcE/Fc*))/(2*c)]2-(FcE/Fc*)/c)= 0.24 From SDPWS Table 4.3.4 Maximum Shear Wall Aspect Ratios Maximum shear wall aspect ratio 3.5 Shear wall length B = 13.8 ft H = 8 ft Page 71 of 213 Length Type H/B Concept 6.75 Wall 1.19 ShearWall 2 Opening 5.05 Wall 1.58 ShearWall Shear capacity adjustment factor – cl.4.3.5.6 Sum of perforated shear wall segment lengths ∑bi=11.8 ft Total area of wall A=110.4 ft 2 Total full height sheathed area A fhs=94.4 ft2 Shear capacity adjustment factor (eqn. 4.3 -6) Co = min(Awall/(3×Ao + Afhs), 1.0)= 0.98220640569395 Perforated shear wall capacity Maximum shear force under wind loading V w_max=0.6×W/1000 =0.663 Kips Shear capacity for wind loading V w=(Vn×CO*∑bi/2000) =5.06 Kips ratio Vw-max / Vw =0.13 PASS - Shear capacity for wind load exceeds maximum shear force Maximum shear force under seismic loading V s_max=0.7×Eq/1000 =0.74 Kips Shear capacity for seismic loading V s=(Vn×CO*∑bi/(2.8×1000)) =3.62 Kips ratio V s_max / Vs =0.2 PASS - Shear capacity for seismic load exceeds maximum shear force Chord capacity for chord1 Load Combination : 0.6DL - 0.7EQ Maximum tensile force in chord T=24.77 lb Maximum applied tensile stress f t=T/Aen=2.46 lb/in2 Design tensile stress f t*=Ft×CD×CMt×Ctt×CFt×Ci=1380 lb/in2 2.46/1380+0 PASS - Design tensile stress exceeds maximum applied tensile stress Load Combination : DL + 0.7EQ Maximum compressive force in chord P=783.52 lb Maximum applied compressive stress f c=P/Ae=63.96 lb/in2 Design compressive stress f c*=Fc×CD×CMc×Ctc×CFc×Ci×Cp=596.16 lb/in2 63.96/596.16=0.11 PASS - Design compressive stress exceeds maximum applied tensile stress Chord capacity for chord2 Load Combination : 0.6DL - 0.7EQ Maximum tensile force in chord T=24.77 lb Page 72 of 213 Maximum applied tensile stress f t=T/Aen=2.46 lb/in2 Design tensile stress f t*=Ft×CD×CMt×Ctt×CFt×Ci=1380 lb/in2 2.46/1380=0 PASS - Design tensile stress exceeds maximum applied tensile stress Load Combination : DL + 0.7EQ Maximum compressive force in chord P=783.52 lb Maximum applied compressive stress f c=P/Ae=63.96 lb/in2 Design compressive stress f c*=Fc×CD×CMc×Ctc×CFc×Ci×Cp=596.16 lb/in2 63.96/596.16=0.11 PASS - Design compressive stress exceeds maximum applied tensile stress bearing compr. stress, bottom plate For (maxi mum compressive force) fc-perp*=Fc-perp×CMc×Ctc×Cb×Ci=625 lb/in2 63.96/625=0.1 PASS - bearing compr. stress, bottom plate Hold down force Chord1 T1=0.02 Kips Chord2 T2=0.02 Kips Wind load deflection Design shear force V δw=FWserv×W=0.5kips Deflection limit Δw_allow=H×12/360= 0.267 in Induced unit shear v δW=VδW/(CO×∑bi)/Cu=43.14lb/ft Anchor tension force Tδ = max(0 ,(v δW /1000)×H×B/Beff- 0.6×(D + Swt×H)×B/2000 - 0.6*min((DT-ch1)/1000,(DT- ch2)/1000) + 0.45×max(abs(W-ch1)/1000, abs(W-ch2)/1000))= 0 kips Chord compression force Cδ = max(0,(vδW/1000)×H×B/Beff+0.6×(D+Swt×H)×B/2000 + 0.6×max((Dc -ch1)/1000,(Dc- ch2)/1000) + 0.45×max(abs(W-ch1)/1000, abs(W-ch2)/1000))= 1.23 kips Vertical elongation at anchor ∆T = Tδ×1000/Ka= 0 in Vertical compression at chord ∆C = 0.04×Cδ*1000/(Ae×Fc -perp)= 0.006 in Total vertical deflection ∆a=(∆T+∆C)×(B/Beff)= 0.006 in Shear wall deflection δsww =2×(vδW/12000)×((H×12)^3)/(3×(E/1000)×Ae×∑bi×12)+(vδW/12000)×H×12/(Ga)+ H×12×∆a /(∑bi×12) = 0.026 in 0.03/0.27=0.1 PASS - Shear wall deflection is less than deflection limit Seismic deflection Design shear force V δs=Eq/1000= 1.06 kips Deflection limit Δ s_allow=0.025×H×12= 2.4 in Induced unit shear v δs=Vδs/CO×∑bi/Cub=91.46 lb/ft Page 73 of 213 Anchor tension force Tδ = max(0,(vδs/1000)*H*B/Beff-(0.6-0.2*SDS)*(DL+ Swt*H)*B/2000 -(0.6-0.2*SDS )* min((DT-ch1)/1000, (DT-ch2)/1000)+max(abs(Eq-ch1)/1000, abs(Eq-ch2)/1000))= 0.38 kips Chord compression force Cδ = max(0,(vδs/1000)*H*B/Beff+(0.6- 0.2*SDS)*(DL+Swt*H)*B/2000 + (0.6-0.2*SDS )* max((Dc-ch1)/1000, (Dc-ch2)/1000)+max(abs(Eq-ch1)/1000, abs(Eq- ch2)/1000))= 1.44 kips Vertical elongation at anchor ∆T = Tδ×1000/Ka= 0.011 in Vertical compression at chord ∆C = 0.04×Cδ*1000/(Ae×Fc -perp)= 0.008 in Total vertical deflection ∆a=(∆T+∆C)×(B/Beff)= 0.02 in Shear wall elastic deflection δswse =2×(vδs/12000)×((H×12)^3)/(3×(E/1000)×Ae×∑bi×12)+(vδss/12000)×H×12/(Ga)+ H×12×∆a /(∑bi×12) = 0.061 in Amp. seis. deflection δsws = Cdδ*δswse /Ie = 0.244 in 0.24/2.4=0.1 PASS - Shear wall deflection is less than deflection limit Page 74 of 213 Collector seismic design force factor F Coll=1 Maximum shear force on wall V max= max(FColl×Vs_max, Vw_max) =0.74kips Maximum force in collector Pcoll=0.073kips Maximum applied tensile stress ft= Tcoll/(1×As) =10.43lb/in2 Design tensile stress Ft'= Ft×CD×CMt×Ctt×CFt×Ci = 1380lb/in2 ft/Ft' =0.01 PASS - Design tensile stress exceeds maximum applied tensile stress Maximum applied compressive stress fc= Pcoll/(1×As) =10.43lb/in2 Column stability factor C P= 1.00 Design tensile stress Fc'=Fc×CD×CMc×Ctc×CFc×Ci×CP = 2484lb/in2 fc/Fc' =0 PASS - Design compressive stress exceeds maximum applied compressive stress Page 75 of 213 Sazan 606 1 LINE D-UPPER R1 Sazan Inc 2024-17-12 DR.Jalalpour 2024-17-12 DR.Razaeian 2024-17-12 Wood shear wall design (NDS) In accordance with NDS2018 allowable stress design and the segmented shear wall method Design summary Shear wall aspect ratio H/B 0.16 OK Shear capacity for seismic loading Vs 4.31 ( ratio =0.17 ) OK Design tensile stress (Ch1) ft' 1380 ( ratio =0 ) OK Design compressive stress (Ch1) fc' 2310.12 ( ratio =0.01 ) OK Design tensile stress (Ch2) ft' 1380 ( ratio =0 ) OK Design compressive stress (Ch2) fc' 2310.12 ( ratio =0.01 ) OK bearing compr. stress, bottom plate fc-perp' 625 ( ratio =0.02 ) OK Hold Down resistance 3950 ( ratio =0 ) OK Shear wall deflection δsww 0.005 ( ratio =0.07 ) OK Panel details Structural I wood panel sheathing on One side Panel height H = 2.25ft Panel length B = 13.8ft Total area of wall A = H x B = 31.05ft2 Panel construction Nominal stud size 2 "x4" Dressed stud size 1.5 "x3.5" Cross-sectional area of studs As= 5.25 in 2 Stud spacing s = 16 in Nominal end post size 1x4 "x4" Dressed end post size 3.5 "x3.5" Cross-sectional area of end posts Ae= 12.25 in 2 Hole diameter Dia = 0 in Net cross-sectional area of end posts Aen= 12.25 in 2 Page 76 of 213 Effective length for chord forces Beff= 13.36 ft Service condition Dry Temperature 100 degF or less Anchor offset e=0 in Anchor Location Inside face Hold Down MST48 Vertical anchor stiffness Ka = 10000 lb/in From NDS Supplement Table 4A - Reference design values for visually graded dimension lumber Species, grade and size classification Douglas Fir-Larch, No.2 grade, 2'' & wider Specific gravity G = 0.5 Tension parallel to grain F t=575 lb/in2 Compression parallel to grain Fc=1350 lb/in2 Compression perpendicular to grain F c_perp=625 lb/in2 Modulus of elasticity E=1600000 lb/in 2 Minimum modulus of elasticity Emin=580000 lb/in2 Sheathing details Sheathing material 15/32'' wood panel structural I 3 -ply plywood sheathing Fastener type 10d Common nail at 6"centers From SDPWS Table 4.3A Nominal Unit Shear Capacities for Wood-Frame Shear Walls - Wood-based Panels Nominal unit shear capacity V n =950×0.92 =874 plf Apparent shear wall shear stiffness G a=16 kips/in Loading details Dead load acting on top of panel DL = 20 lb/ft Floor live load acting on top of panel LL = 13.3 lb/ft Roof live load acting on top of panel Lr = 21.3 lb/ft Self weight of panel Swt = 17 lb/ft 2 In plane wind load acting at head of panel WL = 1105 lbs Snow load acting on top of panel SL = 0 lb/ft Rain load acting on top of panel RL = 0 lb/ft Wind load serviceability factor fwserv = 0.45 In plane seismic load acting at head of panel Eq = 1057 lbs Design spectral response accel. par., short periods S DS ==1.032 Deflection ampification factor Cdδ = 4 Seismic importance factor Ie = 1 Page 77 of 213 Chord Wind Sisemic Dead,comp Dead,Tens Live LiveRoof Snow Rain Ch1 0 0 0 0 0 0 0 0 Ch2 0 0 0 0 0 0 0 0 From ASCE 7-16 - cl.2.4.1 and cl. 2.4.5 Basic combinations Load combination no.1 D + 0.6W Load combination no.2 D + 0.7E Load combination no.3 D + 0.75Lf + 0.45W + 0.75(Lr or S or R) Load combination no.4 D + 0.75Lf + 0.525E + 0.75S Load combination no.5 0.6D + 0.6W Load combination no.6 0.6D + 0.7E Adjustment factors Load duration factor – Table 2.3.2 CD=1.6 Size factor for tension – Table 4A CFt=1.5 Size factor for compression – Table 4A CFc=1.15 Wet service factor for tension – Table 4A CMt=1 Wet service factor for compression – Table 4A CMc=1 Wet service factor for modulus of elasticity – Table 4A CME=1 Temperature factor for tension – Table 2.3.3 Ctt=1 Temperature factor for compression – Table 2.3.3 Ctc=1 Temperature factor for modulus of elasticity – Table 2.3.3 CtE=1 Incising factor – cl.4.3.8 C i=1 Buckling stiffness factor – cl.4.4.2 CT=1 Bearing area factor - cl. 3.10.4 C b=1 For sawn lumber c=0.8 Adjusted modulus of elasticity E min' = Emin× CME× CtE× Ci× CT=580000 psi Critical buckling design value F cE = 0.822×Emin' /(h/d)2= 8011.4 psi Reference compression design value F c* = Fc× CD× CMc× Ctc× CFc× Ci=2484 psi Column stability factor – eqn.3.7-1 Cp = (1+(FcE/Fc*))/(2×c)-√([(1+(FcE/Fc*))/(2*c)]2-(FcE/Fc*)/c)= 0.93 From SDPWS Table 4.3.4 Maximum Shear Wall Aspect Ratios Maximum shear wall aspect ratio 3.5 Shear wall length B = 13.8 ft H = 2.25 ft Shear wall aspect ratio H / B = 0.16 PASS- Maximum shear wall aspect ratio Segmented shear wall capacity Page 78 of 213 Maximum shear force under wind loading V w_max=0.6×W/1000 =0.66 Kips Shear capacity for wind loading V w=(Vn×B/2000) =6.03 Kips ratio V w-max / Vw =0.11 PASS - Shear capacity for wind load exceeds maximum shear force Maximum shear force under seismic loading V s_max=0.7×Eq/1000 =0.74 Kips Shear capacity for seismic loading V s=(Vn×B/(2.8×1000)) =4.31 Kips ratio V s_max / Vs =0.17 PASS - Shear capacity for seismic load exceeds maximum shear force Chord capacity for chord1 Load Combination : 0.6DL - 0.7EQ Maximum tensile force in chord T=0 lb Maximum applied tensile stress f t=T/Aen=0 lb/in2 Design tensile stress f t*=Ft×CD×CMt×Ctt×CFt×Ci=1380 lb/in2 0/1380=0 PASS - Design tensile stress exceeds maximum applied tensile stress Load Combination : DL + 0.7EQ Maximum compressive force in chord P=169.05 lb Maximum applied compressive stress f c=P/Ae=13.8 lb/in2 Design compressive stress f c*=Fc×CD×CMc×Ctc×CFc×Ci×Cp=2310.12 lb/in2 13.8/2310.12=0.01 PASS - Design compressive stress exceeds maximum applied tensile stress Chord capacity for chord2 Load Combination : 0.6DL - 0.7EQ Maximum tensile force in chord T=0 lb Maximum applied tensile stress f t=T/Aen=0 lb/in2 Design tensile stress ft*=Ft×CD×CMt×Ctt×CFt×Ci=1380 lb/in2 0/1380=0 PASS - Design tensile stress exceeds maximum applied tensile stress Load Combination : DL + 0.7EQ Maximum compressive force in chord P=169.05 lb Maximum applied compressive stress f c=P/Ae=13.8 lb/in2 Design compressive stress f c*=Fc×CD×CMc×Ctc×CFc×Ci×Cp=2310.12 lb/in2 13.8/2310.12=0.01 PASS - Design compressive stress exceeds maximum applied tensile stress bearing compr. stress, bottom plate For (maximum compressive force) fc-perp*=Fc-perp×CMc×Ctc×Cb×Ci=625 lb/in2 13.8/625=0.02 PASS - bearing compr. stress, bottom plate Hold down force Page 79 of 213 Chord1 T1=0 Kips Chord2 T2=0 Kips Wind load deflection Design shear force Vδw=FWserv×W=0.5kips Deflection limit Δ w_allow=H×12/360= 0.075 in Induced unit shear vδW=VδW/B/Cub=36.23lb/ft Anchor tension force Tδ = max(0 ,(v δW /1000)×H×B/Beff- 0.6×(D + Swt×H)×B/2000 - 0.6*min((DT-ch1)/1000,(DT- ch2)/1000) + 0.45×max(abs(W-ch1)/1000, abs(W-ch2)/1000))= 0 kips Chord compression force Cδ = max(0,(vδW/1000)×H×B/Beff+0.6×(D+Swt×H)×B/2000 + 0.6×max((Dc -ch1)/1000,(Dc- ch2)/1000) + 0.45×max(abs(W-ch1)/1000, abs(W-ch2)/1000))= 0.33 kips Vertical elongation at anchor ∆T = Tδ×1000/Ka= 0 in Vertical compression at chord ∆C = 0.04×Cδ*1000/(Ae×Fc-perp)= 0.002 in Total vertical deflection ∆a=(∆T+∆C)×(B/Beff)= 0.002 in Shear wall deflection δsww =2×(vδW/12000)×((H×12)^3)/(3×(E/1000)×Ae×B×12)+(vδW/12000)×H×12/(Ga)+ H×12×∆a /(B×12) = 0.005 in 0/0.08=0.07 PASS - Shear wall deflection is less than deflection limit Seismic deflection Design shear force V δs=Eq/1000= 1.06 kips Deflection limit Δ s_allow=0.025×H×12= 0.675 in Induced unit shear v δs=Vδs/B/Cub=76.81 lb/ft Anchor tension force Tδ = max(0,(v δs/1000)*H*B/Beff-(0.6-0.2*SDS)*(DL+ Swt*H)*B/2000 -(0.6-0.2*SDS )* min((DT-ch1)/1000, (DT-ch2)/1000)+max(abs(Eq-ch1)/1000, abs(Eq-ch2)/1000))= 0.02 kips Chord compression force Cδ = max(0,(vδs/1000)*H*B/Beff+(0.6 - 0.2*SDS)*(DL+Swt*H)*B/2000 + (0.6-0.2*SDS )* max((Dc-ch1)/1000, (Dc-ch2)/1000)+max(abs(Eq-ch1)/1000, abs(Eq- ch2)/1000))= 0.34 kips Vertical elongation at anchor ∆T = Tδ×1000/Ka= 0.002 in Vertical compression at chord ∆C = 0.04×Cδ*1000/(Ae×Fc -perp)= 0.002 in Total vertical deflection ∆a=(∆T+∆C)×(B/Beff)= 0.004 in Shear wall elastic deflection δswse =2×(vδs/12000)×((H×12)^3)/(3×(E/1000)×Ae×B×12)+(vδss/12000)×H×12/(Ga)+ H×12×∆a /(B×12) = 0.011 in Amp. seis. deflection δsws = Cdδ*δswse /Ie = 0.044 in 0.04/0.68=0.07 PASS - Shear wall deflection is less than deflection limit Page 80 of 213 S Van Ness Ave Appendix E : Beam and Post Design Page 81 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)693 @ 1' 10"7866 (3.50")Passed (9%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)221 @ 2' 6 13/16"3806 Passed (6%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)-274 @ 1' 10"3722 Passed (7%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.003 @ 0 0.200 Passed (2L/999+)--1.0 D + 1.0 Lr (Alt Spans) Total Load Defl. (in)0.005 @ 0 0.200 Passed (2L/999+)--1.0 D + 1.0 Lr (Alt Spans) Member Length : 4' 4 9/16" System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 2.83/12 •Deflection criteria: LL (L/360) and TL (L/240). •Overhang deflection criteria: LL (0.2") and TL (0.2"). •Left cantilever length exceeds 1/3 member length or 1/2 back span length. Additional bracing should be considered. •A 0.4% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Wind Factored Accessories 1 - Beveled Plate - DF 3.50"3.50"1.50"324 369 -369 693/-27 Blocking 2 - Hanger on 7 1/4" DF beam 1.50"Hanger¹1.50"89 139 45/-170 228/-49 See note ¹ •Dimensions for lateral bracing intervals are measured along the length of the member for sloped conditions. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger U46X SLD13 2.00"N/A 8-10dx1.5 4-10d •Refer to manufacturer notes and instructions for proper installation and use of all connectors. • Side loads are assumed to not induce cross-grain tension. Dead Roof Live Wind Vertical Loads Location (Side)Tributary Width (0.90)(1.25)(1.60)Comments 0 - Self Weight (PLF)0 to 4' 1 1/2"N/A 6.4 ---- 1 - Tapered (PSF)0 to 4' 3"0 to 3'12.6 16.0 -16.0 ROOF 2 - Uniform (PSF)0 to 4' 3"4' 9"12.6 16.0 -16.0 ROOF 3 - Tapered (PSF)0 to 4' 3"0 to 1' 6"12.6 16.0 -16.0 ROOF Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED ROOF, HIP BEAM-1 1 piece(s) 4 x 8 DF No.2 Page 82 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)585 @ 1' 10"7866 (3.50")Passed (7%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)188 @ 2' 6 13/16"3806 Passed (5%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)-225 @ 1' 10"3722 Passed (6%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.002 @ 0 0.200 Passed (2L/999+)--1.0 D + 1.0 Lr (Alt Spans) Total Load Defl. (in)0.004 @ 0 0.200 Passed (2L/999+)--1.0 D + 1.0 Lr (Alt Spans) Member Length : 4' 4 9/16" System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 2.83/12 •Deflection criteria: LL (L/360) and TL (L/240). •Overhang deflection criteria: LL (0.2") and TL (0.2"). •Left cantilever length exceeds 1/3 member length or 1/2 back span length. Additional bracing should be considered. •A 0.4% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Wind Factored Accessories 1 - Beveled Plate - DF 3.50"3.50"1.50"276 309 -309 585/-20 Blocking 2 - Hanger on 7 1/4" DF beam 1.50"Hanger¹1.50"82 124 35/-150 207/-41 See note ¹ •Dimensions for lateral bracing intervals are measured along the length of the member for sloped conditions. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger U46X SLD13 2.00"N/A 8-10dx1.5 4-10d •Refer to manufacturer notes and instructions for proper installation and use of all connectors. • Side loads are assumed to not induce cross-grain tension. Dead Roof Live Wind Vertical Loads Location (Side)Tributary Width (0.90)(1.25)(1.60)Comments 0 - Self Weight (PLF)0 to 4' 1 1/2"N/A 6.4 ---- 1 - Tapered (PSF)0 to 4' 3"0 to 3'12.6 16.0 -16.0 ROOF 2 - Uniform (PSF)0 to 4' 3"3' 9"12.6 16.0 -16.0 ROOF 3 - Tapered (PSF)0 to 4' 3"0 to 1' 6"12.6 16.0 -16.0 ROOF Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED ROOF, HIP BEAM-2 1 piece(s) 4 x 8 DF No.2 Page 83 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)540 @ 1' 10"7866 (3.50")Passed (7%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)174 @ 2' 6 13/16"3806 Passed (5%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)-205 @ 1' 10"3722 Passed (6%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.002 @ 0 0.200 Passed (2L/999+)--1.0 D + 1.0 Lr (Alt Spans) Total Load Defl. (in)0.003 @ 0 0.200 Passed (2L/999+)--1.0 D + 1.0 Lr (Alt Spans) Member Length : 4' 4 9/16" System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 2.83/12 •Deflection criteria: LL (L/360) and TL (L/240). •Overhang deflection criteria: LL (0.2") and TL (0.2"). •Left cantilever length exceeds 1/3 member length or 1/2 back span length. Additional bracing should be considered. •A 0.4% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Wind Factored Accessories 1 - Beveled Plate - DF 3.50"3.50"1.50"256 284 -284 540/-17 Blocking 2 - Hanger on 7 1/4" DF beam 1.50"Hanger¹1.50"79 118 31/-142 198/-37 See note ¹ •Dimensions for lateral bracing intervals are measured along the length of the member for sloped conditions. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger U46X SLD13 2.00"N/A 8-10dx1.5 4-10d •Refer to manufacturer notes and instructions for proper installation and use of all connectors. • Side loads are assumed to not induce cross-grain tension. Dead Roof Live Wind Vertical Loads Location (Side)Tributary Width (0.90)(1.25)(1.60)Comments 0 - Self Weight (PLF)0 to 4' 1 1/2"N/A 6.4 ---- 1 - Tapered (PSF)0 to 4' 3"0 to 3'12.6 16.0 -16.0 ROOF 2 - Uniform (PSF)0 to 4' 3"3' 4"12.6 16.0 -16.0 ROOF 3 - Tapered (PSF)0 to 4' 3"0 to 1' 6"12.6 16.0 -16.0 ROOF Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED ROOF, HIP BEAM-3 1 piece(s) 4 x 8 DF No.2 Page 84 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) [Group] Member Reaction (lbs)2927 @ 2' 11"7656 (3.50")Passed (38%)--1.0 D + 1.0 Lr (All Spans) [1] Shear (lbs)1219 @ 3' 10"4856 Passed (25%)1.25 1.0 D + 1.0 Lr (All Spans) [1] Moment (Ft-lbs)-2679 @ 2' 11"5531 Passed (48%)1.25 1.0 D + 1.0 Lr (All Spans) [1] Live Load Defl. (in)0.049 @ 0 0.200 Passed (2L/999+)--1.0 D + 1.0 Lr (Alt Spans) [1] Total Load Defl. (in)0.071 @ 0 0.292 Passed (2L/992)--1.0 D + 1.0 Lr (Alt Spans) [1] Member Length : 9' 8 7/8" System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •Overhang deflection criteria: LL (0.2") and TL (2L/240). •A 1.5% decrease in the moment capacity has been added to account for lateral stability. •-259 lbs uplift at support located at 2' 11". Strapping or other restraint may be required. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Wind Factored Accessories 1 - Column - DF 3.50"3.50"1.50"1291 1636 -1723 2927/-259 Blocking 2 - Column - DF 1.75"1.75"1.50"345 504 251/-620 849/-165 Blocking Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points • Side loads are assumed to not induce cross-grain tension. Dead Roof Live Wind Vertical Loads Location (Side)Tributary Width (0.90)(1.25)(1.60)Comments 0 - Self Weight (PLF)0 to 9' 8 7/8"N/A 8.2 ---- 1 - Uniform (PLF)0 to 9' 8" (Front)N/A 71.3 90.8 -91.5 Linked from: RR-1, Support 2 2 - Uniform (PLF)0 to 9' 8" (Front)N/A 71.3 90.8 -90.8 Linked from: RR-2, Support 2 3 - Point (lb)0 (Front)N/A 89 139 45/-170 Linked from: HIP BEAM-1, Support 2 4 - Point (lb)0 (Front)N/A 82 124 35/-150 Linked from: HIP BEAM-2, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED ROOF, RB-1 1 piece(s) 4 x 10 DF No.2 Page 85 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) [Group] Member Reaction (lbs)1552 @ 1/4"3828 (1.75")Passed (41%)--1.0 D + 1.0 Lr (Alt Spans) [1] Shear (lbs)1541 @ 9' 1 7/8"4856 Passed (32%)1.25 1.0 D + 1.0 Lr (All Spans) [1] Moment (Ft-lbs)3593 @ 4' 8 1/16"5615 Passed (64%)1.25 1.0 D + 1.0 Lr (Alt Spans) [1] Live Load Defl. (in)0.098 @ 4' 11 1/4"0.335 Passed (L/999+)--1.0 D + 1.0 Lr (Alt Spans) [1] Total Load Defl. (in)0.170 @ 4' 10 13/16"0.503 Passed (L/711)--1.0 D + 1.0 Lr (Alt Spans) [1] Member Length : 12' 2 7/8" System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •Overhang deflection criteria: LL (2L/360) and TL (2L/240). •-261 lbs uplift at support located at 10' 7/8". Strapping or other restraint may be required. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Wind Factored Accessories 1 - Column - DF 1.75"1.75"1.50"687 865 116/-921 1552/-140 Blocking 2 - Column - DF 3.50"3.50"1.50"1336 1686 -1771 3021/-261 Blocking Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points • Side loads are assumed to not induce cross-grain tension. Dead Roof Live Wind Vertical Loads Location (Side)Tributary Width (0.90)(1.25)(1.60)Comments 0 - Self Weight (PLF)0 to 12' 2 7/8"N/A 8.2 ---- 1 - Uniform (PLF)0 to 12' 2" (Front)N/A 71.3 90.8 -91.5 Linked from: RR-1, Support 2 2 - Uniform (PLF)5' 2" to 12' 2" (Front)N/A 71.3 90.8 -91.5 Linked from: RR-1, Support 2 3 - Uniform (PLF)0 to 5' 2" (Front)N/A 71.3 90.8 -90.8 Linked from: RR-2, Support 2 4 - Point (lb)12' 2" (Front)N/A 89 139 45/-170 Linked from: HIP BEAM-1, Support 2 5 - Point (lb)12' 2" (Front)N/A 89 139 45/-170 Linked from: HIP BEAM-1, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED ROOF, RB-2 1 piece(s) 4 x 10 DF No.2 Page 86 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) [Group] Member Reaction (lbs)1332 @ 14'7656 (3.50")Passed (17%)--1.0 D + 1.0 Lr (All Spans) [1] Shear (lbs)543 @ 13' 3"3806 Passed (14%)1.25 1.0 D + 1.0 Lr (All Spans) [1] Moment (Ft-lbs)712 @ 11' 1 15/16"3737 Passed (19%)1.25 1.0 D + 1.0 Lr (Alt Spans) [1] Live Load Defl. (in)0.049 @ 0 0.561 Passed (2L/999+)--1.0 D + 0.6 W (All Spans) [1] Total Load Defl. (in)0.069 @ 0 0.842 Passed (2L/999+)--1.0 D + 0.6 W (All Spans) [1] Member Length : 14' 10" System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •Overhang deflection criteria: LL (2L/360) and TL (2L/240). •Left cantilever length exceeds 1/3 member length or 1/2 back span length. Additional bracing should be considered. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Wind Factored Accessories 1 - Column - DF 3.50"3.50"1.50"380 359 51/-386 739/-4 Blocking 2 - Column - DF 3.50"3.50"1.50"557 775 -835 1332/-167 Blocking Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points • Side loads are assumed to not induce cross-grain tension. Dead Roof Live Wind Vertical Loads Location (Side)Tributary Width (0.90)(1.25)(1.60)Comments 0 - Self Weight (PLF)0 to 14' 10"N/A 6.4 ---- 1 - Uniform (PLF)8' 5" to 14' 10" (Front)N/A 53.3 68.3 -69.0 Linked from: RR-4, Support 2 2 - Uniform (PLF)8' 5" to 14' 10" (Front)N/A 53.3 68.3 -69.0 Linked from: RR-4, Support 2 3 - Point (lb)14' 10" (Front)N/A 79 118 31/-142 Linked from: HIP BEAM-3, Support 2 4 - Point (lb)14' 10" (Front)N/A 79 118 31/-142 Linked from: HIP BEAM-3, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED ROOF, RB-3 1 piece(s) 4 x 8 DF No.2 Page 87 of 213 Wall Height: 8'Member Height: 7' 7 1/2"Tributary Width: 1' 4" Design Results Actual Allowed Result LDF Load: Combination Slenderness 26 50 Passed (52%)---- Compression (lbs)693 7787 Passed (9%)1.25 1.0 D + 1.0 Lr Plate Bearing (lbs)693 7656 Passed (9%)--1.0 D + 1.0 Lr Lateral Reaction (lbs)52 ----1.60 1.0 D + 0.6 W Lateral Shear (lbs)48 2352 Passed (2%)1.60 1.0 D + 0.6 W Lateral Moment (ft-lbs)98 @ mid-span 1286 Passed (8%)1.60 1.0 D + 0.6 W Total Deflection (in)0.04 @ mid-span 0.25 Passed (L/2541)--1.0 D + 0.6 W Bending/Compression 0.08 1 Passed (8%)1.60 1.0 D + 0.6 W •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Member connection at both ends must be checked against an uplift of -45. •Applicable calculations are based on NDS. •This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 7' 7 1/2" System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d (0.113" x 2 1/2") (Toe)2 N/A Base Nails 8d (0.113" x 2 1/2") (Toe)2 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Dead Roof Live Wind Vertical Load Tributary Width (0.90)(1.25)(1.60)Comments 1 - Point (lb)N/A 324 369 -369 Linked from: HIP BEAM-1, Support 1 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (13' 1"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Wind Zone (4), GCpi (+/- 0.18), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 1' 4"16.9 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED ROOF, C-1 1 piece(s) 4 x 4 DF No.2 Page 88 of 213 Wall Height: 8'Member Height: 7' 7 1/2"Tributary Width: 1' 4" Design Results Actual Allowed Result LDF Load: Combination Slenderness 26 50 Passed (52%)---- Compression (lbs)585 7787 Passed (8%)1.25 1.0 D + 1.0 Lr Plate Bearing (lbs)585 7656 Passed (8%)--1.0 D + 1.0 Lr Lateral Reaction (lbs)52 ----1.60 1.0 D + 0.6 W Lateral Shear (lbs)48 2352 Passed (2%)1.60 1.0 D + 0.6 W Lateral Moment (ft-lbs)98 @ mid-span 1286 Passed (8%)1.60 1.0 D + 0.6 W Total Deflection (in)0.04 @ mid-span 0.25 Passed (L/2541)--1.0 D + 0.6 W Bending/Compression 0.08 1 Passed (8%)1.60 1.0 D + 0.6 W •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Member connection at both ends must be checked against an uplift of -33. •Applicable calculations are based on NDS. •This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 7' 7 1/2" System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d (0.113" x 2 1/2") (Toe)2 N/A Base Nails 8d (0.113" x 2 1/2") (Toe)2 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Dead Roof Live Wind Vertical Load Tributary Width (0.90)(1.25)(1.60)Comments 1 - Point (lb)N/A 276 309 -309 Linked from: HIP BEAM-2, Support 1 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (13' 1"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Wind Zone (4), GCpi (+/- 0.18), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 1' 4"16.9 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED ROOF, C-2 1 piece(s) 4 x 4 DF No.2 Page 89 of 213 Wall Height: 8'Member Height: 7' 7 1/2"Tributary Width: 1' 4" Design Results Actual Allowed Result LDF Load: Combination Slenderness 26 50 Passed (52%)---- Compression (lbs)2927 7787 Passed (38%)1.25 1.0 D + 1.0 Lr Plate Bearing (lbs)2927 7656 Passed (38%)--1.0 D + 1.0 Lr Lateral Reaction (lbs)0 ------N/A Lateral Shear (lbs)0 N/A Passed (N/A)--N/A Lateral Moment (ft-lbs)0 @ mid-span N/A Passed (N/A)--N/A Total Deflection (in)0.00 @ mid-span N/A Passed (N/A)--N/A Bending/Compression N/A 1 Passed (N/A)--N/A •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Member connection at both ends must be checked against an uplift of -432. •Applicable calculations are based on NDS. •This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 7' 7 1/2" System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Dead Roof Live Wind Vertical Load Tributary Width (0.90)(1.25)(1.60)Comments 1 - Point (lb)N/A 1291 1636 -1723 Linked from: RB-1, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED ROOF, C-3 1 piece(s) 4 x 4 DF No.2 Page 90 of 213 Post Height: 4' 7" Design Results Actual Allowed Result LDF Load: Combination [Load Group] Slenderness 16 50 Passed (31%)---- Compression (lbs)2401 16384 Passed (15%)1.25 1.0 D + 1.0 Lr [1] Base Bearing (lbs)2401 363825 Passed (1%)--1.0 D + 1.0 Lr [1] Bending/Compression N/A 1 Passed (N/A)--N/A •Input axial load eccentricity for the design is zero •Member connection at both ends must be checked against an uplift of -509. •Applicable calculations are based on NDS. Supports Type Material Base Plate Steel Max Unbraced Length Comments Full Member Length No bracing assumed. Member Type : Free Standing Post Building Code : IBC 2021 Design Methodology : ASD Dead Roof Live Wind Vertical Loads (0.90)(1.25)(1.60)Comments 1 - Point (lb)345 504 251/-620 Linked from: RB-1, Support 2 2 - Point (lb)687 865 116/-921 Linked from: RB-2, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED ROOF, C-4 1 piece(s) 4 x 4 DF No.2 Page 91 of 213 Post Height: 4' 7" Design Results Actual Allowed Result LDF Load: Combination Slenderness 16 50 Passed (31%)---- Compression (lbs)3022 16384 Passed (18%)1.25 1.0 D + 1.0 Lr Base Bearing (lbs)3022 363825 Passed (1%)--1.0 D + 1.0 Lr Bending/Compression N/A 1 Passed (N/A)--N/A •Input axial load eccentricity for the design is zero •Member connection at both ends must be checked against an uplift of -435. •Applicable calculations are based on NDS. Supports Type Material Base Plate Steel Max Unbraced Length Comments Full Member Length No bracing assumed. Member Type : Free Standing Post Building Code : IBC 2021 Design Methodology : ASD Dead Roof Live Wind Vertical Load (0.90)(1.25)(1.60)Comments 1 - Point (lb)1336 1686 -1771 Linked from: RB-2, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED ROOF, C-5 1 piece(s) 4 x 4 DF No.2 Page 92 of 213 Post Height: 4' Design Results Actual Allowed Result LDF Load: Combination [Load Group] Slenderness 14 50 Passed (27%)---- Compression (lbs)739 18410 Passed (4%)1.25 1.0 D + 1.0 Lr [1] Base Bearing (lbs)739 363825 Passed (0%)--1.0 D + 1.0 Lr [1] Bending/Compression N/A 1 Passed (N/A)--N/A •Input axial load eccentricity for the design is zero •Member connection at both ends must be checked against an uplift of -6. •Applicable calculations are based on NDS. Supports Type Material Base Plate Steel Max Unbraced Length Comments Full Member Length No bracing assumed. Member Type : Free Standing Post Building Code : IBC 2021 Design Methodology : ASD Dead Roof Live Wind Vertical Load (0.90)(1.25)(1.60)Comments 1 - Point (lb)380 359 51/-386 Linked from: RB-3, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED ROOF, C-6 1 piece(s) 4 x 4 DF No.2 Page 93 of 213 Post Height: 4' Design Results Actual Allowed Result LDF Load: Combination Slenderness 14 50 Passed (27%)---- Compression (lbs)1332 18410 Passed (7%)1.25 1.0 D + 1.0 Lr Base Bearing (lbs)1332 363825 Passed (0%)--1.0 D + 1.0 Lr Bending/Compression N/A 1 Passed (N/A)--N/A •Input axial load eccentricity for the design is zero •Member connection at both ends must be checked against an uplift of -278. •Applicable calculations are based on NDS. Supports Type Material Base Plate Steel Max Unbraced Length Comments Full Member Length No bracing assumed. Member Type : Free Standing Post Building Code : IBC 2021 Design Methodology : ASD Dead Roof Live Wind Vertical Load (0.90)(1.25)(1.60)Comments 1 - Point (lb)557 775 -835 Linked from: RB-3, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED ROOF, C-7 1 piece(s) 4 x 4 DF No.2 Page 94 of 213 Wall Height: 8'Member Height: 7' 7 1/2"Tributary Width: 1' 4" Design Results Actual Allowed Result LDF Load: Combination Slenderness 26 50 Passed (52%)---- Compression (lbs)540 7787 Passed (7%)1.25 1.0 D + 1.0 Lr Plate Bearing (lbs)540 7656 Passed (7%)--1.0 D + 1.0 Lr Lateral Reaction (lbs)52 ----1.60 1.0 D + 0.6 W Lateral Shear (lbs)48 2352 Passed (2%)1.60 1.0 D + 0.6 W Lateral Moment (ft-lbs)98 @ mid-span 1286 Passed (8%)1.60 1.0 D + 0.6 W Total Deflection (in)0.04 @ mid-span 0.25 Passed (L/2541)--1.0 D + 0.6 W Bending/Compression 0.08 1 Passed (8%)1.60 1.0 D + 0.6 W •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Member connection at both ends must be checked against an uplift of -28. •Applicable calculations are based on NDS. •This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 7' 7 1/2" System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d (0.113" x 2 1/2") (Toe)2 N/A Base Nails 8d (0.113" x 2 1/2") (Toe)2 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Dead Roof Live Wind Vertical Load Tributary Width (0.90)(1.25)(1.60)Comments 1 - Point (lb)N/A 256 284 -284 Linked from: HIP BEAM-3, Support 1 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (13' 1"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Wind Zone (4), GCpi (+/- 0.18), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 1' 4"16.9 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED ROOF, C-8 1 piece(s) 4 x 4 DF No.2 Page 95 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1044 @ 11' 9"7656 (3.50")Passed (14%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)1027 @ 10' 10 1/4"4856 Passed (21%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)3465 @ 8' 4"5541 Passed (63%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.093 @ 6' 6 7/16"0.386 Passed (L/999+)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.179 @ 6' 5 11/16"0.579 Passed (L/777)--1.0 D + 1.0 Lr (All Spans) Member Length : 11' 11" System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •A 1.3% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Roof Live Wind Factored Accessories 1 - Stud wall - DF 3.50"3.50"1.50"264 159 229 -246 555 Blocking 2 - Stud wall - DF 3.50"3.50"1.50"498 159 546 -589 1044/-54 Blocking Lateral Bracing Bracing Intervals Comments Top Edge (Lu)6' o/c Bottom Edge (Lu)End Bearing Points • Side loads are assumed to not induce cross-grain tension. Dead Floor Live Roof Live Wind Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 0 - Self Weight (PLF)0 to 11' 11"N/A 8.2 ------ 1 - Uniform (PSF)0 to 11' 11" (Front)1' 4"6.0 20.0 --CLG 2 - Point (lb)8' 4" (Top)N/A 569 -775 -835 Linked from: C-7, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, CB-1 1 piece(s) 4 x 10 DF No.2 Page 96 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) [Group] Member Reaction (lbs)1639 @ 11' 9"7656 (3.50")Passed (21%)--1.0 D + 1.0 Lr (All Spans) [1] Shear (lbs)1447 @ 10' 10 1/4"4856 Passed (30%)1.25 1.0 D + 1.0 Lr (All Spans) [1] Moment (Ft-lbs)4521 @ 7' 2 3/4"5516 Passed (82%)1.25 1.0 D + 1.0 Lr (All Spans) [1] Live Load Defl. (in)0.144 @ 6' 1 7/16"0.386 Passed (L/966)--1.0 D + 1.0 Lr (All Spans) [1] Total Load Defl. (in)0.292 @ 6' 1 5/8"0.579 Passed (L/476)--1.0 D + 1.0 Lr (All Spans) [1] Member Length : 11' 11" System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Roof Live Wind Factored Accessories 1 - Stud wall - DF 3.50"3.50"1.50"655 185 656 -664 1310/-5 Blocking 2 - Stud wall - DF 3.50"3.50"1.50"837 247 803 -822 1639 Blocking Lateral Bracing Bracing Intervals Comments Top Edge (Lu)8' o/c Bottom Edge (Lu)End Bearing Points • Side loads are assumed to not induce cross-grain tension. Dead Floor Live Roof Live Wind Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 0 - Self Weight (PLF)0 to 11' 11"N/A 8.2 ------ 1 - Uniform (PSF)0 to 11' 11" (Front)8"6.0 20.0 ----CLG 2 - Uniform (PSF)0 to 11' 11" (Front)8"6.0 20.0 ----CLG 3 - Point (lb)9' 1" (Front)N/A 39 114 ----Linked from: CB-12, Support 1 4 - Point (lb)8' 4" (Top)N/A 392 --359 51/-386 Linked from: C-6, Support 1 5 - Uniform (PLF)0 to 11' 11" (Top)N/A 72.8 --92.3 -92.3 Linked from: RR-2, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, CB-2 1 piece(s) 4 x 10 DF No.2 Page 97 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1305 @ 2"7656 (3.50")Passed (17%)--1.0 D + 1.0 L (All Spans) Shear (lbs)1120 @ 1' 3/4"3885 Passed (29%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)3430 @ 5' 2 3/16"4432 Passed (77%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.153 @ 5' 8 5/8"0.376 Passed (L/883)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.213 @ 5' 8 1/2"0.565 Passed (L/637)--1.0 D + 1.0 L (All Spans) Member Length : 11' 7 1/2" System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •A 1.3% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Factored Accessories 1 - Stud wall - DF 3.50"3.50"1.50"366 938 1305 Blocking 2 - Stud wall - DF 3.50"3.50"1.50"307 815 1122 Blocking Lateral Bracing Bracing Intervals Comments Top Edge (Lu)8' o/c Bottom Edge (Lu)End Bearing Points • Side loads are assumed to not induce cross-grain tension. Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 11' 7 1/2"N/A 8.2 -- 1 - Uniform (PSF)0 to 11' 7 1/2" (Front)8"6.0 20.0 CLG 2 - Uniform (PLF)0 to 2' 4" (Front)N/A 34.5 114.0 Linked from: CJ-5, Support 2 3 - Uniform (PLF)2' 4" to 4' 2" (Front)N/A 24.8 81.8 Linked from: CJ-7, Support 2 4 - Uniform (PLF)4' 2" to 11' 7 1/2" (Front)N/A 34.5 114.0 Linked from: CJ-5, Support 2 5 - Point (lb)2' 4" (Front)N/A 74 166 Linked from: CB-11, Support 2 6 - Point (lb)4' 2" (Front)N/A 74 166 Linked from: CB-11, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, CB-3 1 piece(s) 4 x 10 DF No.2 Page 98 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1650 @ 1 1/2"3281 (1.50")Passed (50%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)1625 @ 8 3/4"3806 Passed (43%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)3415 @ 2' 3"3709 Passed (92%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.029 @ 2' 3 11/16"0.146 Passed (L/999+)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.053 @ 2' 3 11/16"0.219 Passed (L/985)--1.0 D + 1.0 Lr (All Spans) Member Length : 4' 4 1/2" System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top custom unbraced length is too long and has been reset to the member length of 4' 4 1/2" •A 0.8% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Roof Live Wind Factored Accessories 1 - Hanger on 7 1/4" DF beam 1.50"Hanger¹1.50"787 263 867 -911 1654/-74 See note ¹ 2 - Hanger on 7 1/4" DF beam 1.50"Hanger¹1.50"749 263 819 -860 1567/-67 See note ¹ Lateral Bracing Bracing Intervals Comments Top Edge (Lu)4' 5" o/c Bottom Edge (Lu)End Bearing Points Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1 - Face Mount Hanger HHUS46 3.00"N/A 14-10d 6-10d 2 - Face Mount Hanger LUS48 2.00"N/A 6-SD9112 4-SD9212 •Refer to manufacturer notes and instructions for proper installation and use of all connectors. • Side loads are assumed to not induce cross-grain tension. Dead Floor Live Roof Live Wind Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 0 - Self Weight (PLF)1 1/2" to 4' 6"N/A 6.4 ------ 1 - Uniform (PLF)0 to 4' 7 1/2" (Front)N/A 30.0 100.5 --Linked from: CJ-2, Support 2 2 - Uniform (PSF)0 to 4' 7 1/2" (Front)8"6.0 20.0 --CLG 3 - Point (lb)2' 3" (Top)N/A 1350 -1686 -1771 Linked from: C-5, Support 1 Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, CB-4 1 piece(s) 4 x 8 DF No.2 Page 99 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)999 @ 1 1/2"3281 (1.50")Passed (30%)--1.0 D + 1.0 L (All Spans) Shear (lbs)1585 @ 10' 11"3885 Passed (41%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)3521 @ 7' 2 1/16"4432 Passed (79%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.149 @ 6' 3 3/8"0.390 Passed (L/941)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Total Load Defl. (in)0.250 @ 6' 3 15/16"0.584 Passed (L/562)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Member Length : 11' 10 1/4" System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •A 1.3% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Roof Live Wind Factored Accessories 1 - Hanger on 9 1/4" DF beam 1.50"Hanger¹1.50"356 660 133 -140 1016 See note ¹ 2 - Column - DF 3.50"3.50"1.50"881 899 686 -720 2070 Blocking Lateral Bracing Bracing Intervals Comments Top Edge (Lu)8' o/c Bottom Edge (Lu)End Bearing Points Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1 - Face Mount Hanger LUS410 2.00"N/A 8-10dx1.5 6-10d •Refer to manufacturer notes and instructions for proper installation and use of all connectors. • Side loads are assumed to not induce cross-grain tension. Dead Floor Live Roof Live Wind Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 0 - Self Weight (PLF)1 1/2" to 11' 11 3/4"N/A 8.2 ------ 1 - Uniform (PLF)0 to 11' 11 3/4" (Front)N/A 27.0 89.3 --Linked from: CJ-1, Support 2 2 - Uniform (PSF)0 to 9' 11" (Front)8"6.0 20.0 --CLG 3 - Uniform (PLF)9' 11" to 11' 11 3/4" (Front)N/A 13.5 45.8 --Linked from: CJ-3, Support 2 4 - Point (lb)9' 11" (Front)N/A 749 263 819 -860 Linked from: CB-4, Support 2 Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, CB-5 1 piece(s) 4 x 10 DF No.2 Page 100 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2124 @ 11' 11 1/2"7656 (3.50")Passed (28%)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Shear (lbs)1618 @ 11' 3/4"3885 Passed (42%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)3706 @ 7' 4 3/4"4432 Passed (84%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.161 @ 6' 4 11/16"0.393 Passed (L/880)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Total Load Defl. (in)0.271 @ 6' 5 5/16"0.590 Passed (L/522)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Member Length : 12' 1 1/2" System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •A 1.3% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Roof Live Wind Factored Accessories 1 - Column - DF 3.50"3.50"1.50"376 673 150 -158 1049 Blocking 2 - Column - DF 3.50"3.50"1.50"908 905 717 -753 2124 Blocking Lateral Bracing Bracing Intervals Comments Top Edge (Lu)8' o/c Bottom Edge (Lu)End Bearing Points • Side loads are assumed to not induce cross-grain tension. Dead Floor Live Roof Live Wind Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 0 - Self Weight (PLF)0 to 12' 1 1/2"N/A 8.2 ------ 1 - Uniform (PLF)0 to 12' 1 1/2" (Front)N/A 27.0 89.3 --Linked from: CJ-1, Support 2 2 - Uniform (PSF)0 to 9' 11" (Front)8"6.0 20.0 --CLG 3 - Uniform (PLF)9' 11" to 12' 1 1/2" (Front)N/A 13.5 45.8 --Linked from: CJ-3, Support 1 4 - Point (lb)9' 11" (Front)N/A 787 263 867 -911 Linked from: CB-4, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, CB-6 1 piece(s) 4 x 10 DF No.2 Page 101 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) [Group] Member Reaction (lbs)2569 @ 2"7656 (3.50")Passed (34%)--1.0 D + 0.45 W + 0.75 L + 0.75 Lr (All Spans) [1] Shear (lbs)2331 @ 1' 3/4"4856 Passed (48%)1.25 1.0 D + 0.75 L + 0.75 Lr (All Spans) [1] Moment (Ft-lbs)2992 @ 3' 10"4441 Passed (67%)1.00 1.0 D + 1.0 L (All Spans) [1] Live Load Defl. (in)0.045 @ 3' 4 9/16"0.226 Passed (L/999+)--1.0 D + 0.45 W + 0.75 L + 0.75 Lr (All Spans) [1] Total Load Defl. (in)0.079 @ 3' 4 7/16"0.340 Passed (L/999+)--1.0 D + 0.45 W + 0.75 L + 0.75 Lr (All Spans) [1] Member Length : 7' 1 1/2" System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top custom unbraced length is too long and has been reset to the member length of 6' 9 1/2" •A 1.1% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Roof Live Wind Factored Accessories 1 - Column - DF 3.50"3.50"1.50"1123 647 1145 226/-1284 2569/-96 Blocking 2 - Column - DF 3.50"3.50"1.50"494 538 357 1/-397 1166 Blocking Lateral Bracing Bracing Intervals Comments Top Edge (Lu)6' 10" o/c Bottom Edge (Lu)End Bearing Points • Side loads are assumed to not induce cross-grain tension. Dead Floor Live Roof Live Wind Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 0 - Self Weight (PLF)0 to 7' 1 1/2"N/A 8.2 ------ 1 - Uniform (PLF)0 to 3' 10" (Front)N/A 30.0 100.5 --Linked from: CJ-2, Support 1 2 - Uniform (PSF)0 to 7' 1 1/2" (Front)8"6.0 20.0 --CLG 3 - Uniform (PSF)3' 10" to 7' 1 1/2" (Front)8"6.0 20.0 --CLG 4 - Point (lb)3' 10" (Front)N/A 356 660 133 -140 Linked from: CB-5, Support 1 5 - Point (lb)1' 7" (Top)N/A 1046 -1369 367/-1541 Linked from: C-4, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, CB-7 1 piece(s) 4 x 10 DF No.2 Page 102 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1133 @ 2"7656 (3.50")Passed (15%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)816 @ 3' 10 3/4"3806 Passed (21%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)773 @ 2' 7 1/4"3708 Passed (21%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.006 @ 2' 5 1/8"0.149 Passed (L/999+)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.017 @ 2' 5"0.223 Passed (L/999+)--1.0 D + 1.0 Lr (All Spans) Member Length : 4' 9 1/2" System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •A 0.8% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Wind Factored Accessories 1 - Column - DF 3.50"3.50"1.50"655 478 -478 1133 Blocking 2 - Column - DF 3.50"3.50"1.50"622 443 -443 1066 Blocking Lateral Bracing Bracing Intervals Comments Top Edge (Lu)4' 9 1/2" o/c Bottom Edge (Lu)End Bearing Points • Side loads are assumed to not induce cross-grain tension. Dead Roof Live Wind Vertical Loads Location (Side)Tributary Width (0.90)(1.25)(1.60)Comments 0 - Self Weight (PLF)0 to 4' 9 1/2"N/A 6.4 ---- 1 - Point (lb)7" (Top)N/A 348 369 -369 Linked from: C-1, Support 1 2 - Point (lb)4' (Top)N/A 348 369 -369 Linked from: C-1, Support 1 3 - Uniform (PLF)0 to 4' 9 1/2" (Front)N/A 30.0 38.3 -38.3 Linked from: RR-5, Support 1 4 - Uniform (PSF)0 to 4' 9 1/2" (Top)5'17.0 --WALL Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, CB-8 1 piece(s) 4 x 8 DF No.2 Page 103 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)17 @ 1 1/2"2813 (1.50")Passed (1%)--1.0 D + 1.0 L (All Spans) Shear (lbs)7 @ 7"1980 Passed (0%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)7 @ 11"1466 Passed (0%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.000 @ 1 1/2"0.053 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.000 @ 1 1/2"0.079 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Member Length : 1' 7" System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top custom unbraced length is too long and has been reset to the member length of 1' 7" •A 0.6% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Factored Accessories 1 - Hanger on 5 1/2" DF beam 1.50"Hanger¹1.50"7 12 19 See note ¹ 2 - Hanger on 5 1/2" DF beam 1.50"Hanger¹1.50"7 12 19 See note ¹ Lateral Bracing Bracing Intervals Comments Top Edge (Lu)1' 7" o/c Bottom Edge (Lu)End Bearing Points Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1 - Face Mount Hanger LUS26-2 2.00"N/A 4-10dx1.5 3-10d 2 - Face Mount Hanger LUS26-2 2.00"N/A 4-10dx1.5 3-10d •Refer to manufacturer notes and instructions for proper installation and use of all connectors. • Side loads are assumed to not induce cross-grain tension. Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)1 1/2" to 1' 8 1/2"N/A 4.2 -- 1 - Uniform (PSF)0 to 1' 10" (Front)8"6.0 20.0 CLG Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, CB-9 2 piece(s) 2 x 6 DF No.2 Page 104 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)88 @ 1 1/2"2813 (1.50")Passed (3%)--1.0 D + 1.0 L (All Spans) Shear (lbs)37 @ 7"1980 Passed (2%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)35 @ 11"1466 Passed (2%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.000 @ 11"0.053 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.000 @ 11"0.079 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Member Length : 1' 7" System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Top custom unbraced length is too long and has been reset to the member length of 1' 7" •A 0.6% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Factored Accessories 1 - Hanger on 5 1/2" DF beam 1.50"Hanger¹1.50"26 75 101 See note ¹ 2 - Hanger on 5 1/2" DF beam 1.50"Hanger¹1.50"26 75 101 See note ¹ Lateral Bracing Bracing Intervals Comments Top Edge (Lu)1' 7" o/c Bottom Edge (Lu)End Bearing Points Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1 - Face Mount Hanger LUS26-2 2.00"N/A 4-10dx1.5 3-10d 2 - Face Mount Hanger LUS26-2 2.00"N/A 4-10dx1.5 3-10d •Refer to manufacturer notes and instructions for proper installation and use of all connectors. • Side loads are assumed to not induce cross-grain tension. Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)1 1/2" to 1' 8 1/2"N/A 4.2 -- 1 - Uniform (PLF)0 to 1' 10" (Front)N/A 24.8 81.8 Linked from: CJ-7, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, CB-10 2 piece(s) 2 x 6 DF No.2 Page 105 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)236 @ 11' 3 1/4"2813 (1.50")Passed (8%)--1.0 D + 1.0 L (All Spans) Shear (lbs)245 @ 9"1980 Passed (12%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)719 @ 5' 2 1/4"1419 Passed (51%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.167 @ 5' 7 7/16"0.370 Passed (L/798)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.241 @ 5' 7 1/2"0.555 Passed (L/553)--1.0 D + 1.0 L (All Spans) Member Length : 11' 3 1/4" System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •A 3.8% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Factored Accessories 1 - Stud wall - DF 3.50"3.50"1.50"85 183 268 Blocking 2 - Hanger on 5 1/2" DF beam 1.50"Hanger¹1.50"74 166 241 See note ¹ Lateral Bracing Bracing Intervals Comments Top Edge (Lu)8' o/c Bottom Edge (Lu)End Bearing Points Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger LUS26-2 2.00"N/A 4-10dx1.5 3-10d •Refer to manufacturer notes and instructions for proper installation and use of all connectors. • Side loads are assumed to not induce cross-grain tension. Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 11' 3 1/4"N/A 4.2 -- 1 - Point (lb)7" (Front)N/A 7 12 Linked from: CB-9, Support 2 2 - Point (lb)3' 1" (Front)N/A 26 75 Linked from: CB-10, Support 2 3 - Uniform (PSF)3' 1" to 11' 4 3/4" (Front)8"6.0 20.0 CLG 4 - Uniform (PSF)0 to 11' 4 3/4" (Front)8"6.0 20.0 CLG Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, CB-11 2 piece(s) 2 x 6 DF No.2 Page 106 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)139 @ 1 1/2"2813 (1.50")Passed (5%)--1.0 D + 1.0 L (All Spans) Shear (lbs)82 @ 7"1980 Passed (4%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)78 @ 1' 3"1463 Passed (5%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.001 @ 1' 3"0.075 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.001 @ 1' 3"0.112 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Member Length : 2' 3" System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Applicable calculations are based on NDS. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Factored Accessories 1 - Hanger on 5 1/2" DF beam 1.50"Hanger¹1.50"39 114 154 See note ¹ 2 - Hanger on 5 1/2" DF beam 1.50"Hanger¹1.50"39 114 154 See note ¹ Lateral Bracing Bracing Intervals Comments Top Edge (Lu)2' 3" o/c Bottom Edge (Lu)End Bearing Points Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1 - Face Mount Hanger LUS26-2 2.00"N/A 4-10dx1.5 3-10d 2 - Face Mount Hanger LUS26-2 2.00"N/A 4-10dx1.5 3-10d •Refer to manufacturer notes and instructions for proper installation and use of all connectors. • Side loads are assumed to not induce cross-grain tension. Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)1 1/2" to 2' 4 1/2"N/A 4.2 -- 1 - Uniform (PLF)0 to 2' 6" (Front)N/A 27.8 91.5 Linked from: CJ-9, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, CB-12 2 piece(s) 2 x 6 DF No.2 Page 107 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)303 @ 11' 5 3/4"2813 (1.50")Passed (11%)--1.0 D + 1.0 L (All Spans) Shear (lbs)291 @ 10' 10 3/4"1980 Passed (15%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)790 @ 6' 6 1/2"1419 Passed (56%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.193 @ 5' 11 3/4"0.377 Passed (L/702)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.277 @ 5' 11 11/16"0.566 Passed (L/490)--1.0 D + 1.0 L (All Spans) Member Length : 11' 5 3/4" System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Factored Accessories 1 - Stud wall - DF 3.50"3.50"1.50"78 176 254 Blocking 2 - Stud wall - DF 1.50"1.50"1.50"91 212 303 Blocking Lateral Bracing Bracing Intervals Comments Top Edge (Lu)8' o/c Bottom Edge (Lu)End Bearing Points • Side loads are assumed to not induce cross-grain tension. Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 11' 5 3/4"N/A 4.2 -- 1 - Uniform (PSF)0 to 9' 1" (Front)8"6.0 20.0 CLG 2 - Uniform (PSF)0 to 11' 5 3/4" (Front)8"6.0 20.0 CLG 3 - Point (lb)9' 1" (Front)N/A 39 114 Linked from: CB-12, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, CB-13 2 piece(s) 2 x 6 DF No.2 Page 108 of 213 Wall Height: 8'Member Height: 7' 7 1/2"Tributary Width: 1' 4" Design Results Actual Allowed Result LDF Load: Combination Slenderness 26 50 Passed (52%)---- Compression (lbs)1133 7787 Passed (15%)1.25 1.0 D + 1.0 Lr Plate Bearing (lbs)1133 7656 Passed (15%)--1.0 D + 1.0 Lr Lateral Reaction (lbs)52 ----1.60 1.0 D + 0.6 W Lateral Shear (lbs)48 2352 Passed (2%)1.60 1.0 D + 0.6 W Lateral Moment (ft-lbs)98 @ mid-span 1286 Passed (8%)1.60 1.0 D + 0.6 W Total Deflection (in)0.04 @ mid-span 0.25 Passed (L/2541)--1.0 D + 0.6 W Bending/Compression 0.08 1 Passed (8%)1.60 1.0 D + 0.6 W •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. •This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 7' 7 1/2" System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d (0.113" x 2 1/2") (Toe)2 N/A Base Nails 8d (0.113" x 2 1/2") (Toe)2 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Dead Roof Live Wind Vertical Load Tributary Width (0.90)(1.25)(1.60)Comments 1 - Point (lb)N/A 655 478 -478 Linked from: CB-8, Support 1 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8' 6"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Wind Zone (4), GCpi (+/- 0.18), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 1' 4"16.9 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, C-9 1 piece(s) 4 x 4 DF No.2 Page 109 of 213 Wall Height: 8'Member Height: 7' 7 1/2"Tributary Width: 1' 4" Design Results Actual Allowed Result LDF Load: Combination Slenderness 26 50 Passed (52%)---- Compression (lbs)2125 7787 Passed (27%)1.25 1.0 D + 0.75 L + 0.75 Lr Plate Bearing (lbs)2125 7656 Passed (28%)--1.0 D + 0.75 L + 0.75 Lr Lateral Reaction (lbs)52 ----1.60 1.0 D + 0.6 W Lateral Shear (lbs)48 2352 Passed (2%)1.60 1.0 D + 0.6 W Lateral Moment (ft-lbs)98 @ mid-span 1286 Passed (8%)1.60 1.0 D + 0.6 W Total Deflection (in)0.04 @ mid-span 0.25 Passed (L/2541)--1.0 D + 0.6 W Bending/Compression 0.12 1 Passed (12%)1.60 1.0 D + 0.45 W + 0.75 L + 0.75 Lr •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. •This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 7' 7 1/2" System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d (0.113" x 2 1/2") (Toe)2 N/A Base Nails 8d (0.113" x 2 1/2") (Toe)2 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Dead Floor Live Roof Live Wind Vertical Load Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 1 - Point (lb)N/A 908 905 717 -753 Linked from: CB-6, Support 2 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8' 6"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Wind Zone (4), GCpi (+/- 0.18), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 1' 4"16.9 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, C-10 1 piece(s) 4 x 4 DF No.2 Page 110 of 213 Wall Height: 8'Member Height: 7' 7 1/2"Tributary Width: 1' 4" Design Results Actual Allowed Result LDF Load: Combination Slenderness 26 50 Passed (52%)---- Compression (lbs)2070 7787 Passed (27%)1.25 1.0 D + 0.75 L + 0.75 Lr Plate Bearing (lbs)2070 7656 Passed (27%)--1.0 D + 0.75 L + 0.75 Lr Lateral Reaction (lbs)52 ----1.60 1.0 D + 0.6 W Lateral Shear (lbs)48 2352 Passed (2%)1.60 1.0 D + 0.6 W Lateral Moment (ft-lbs)98 @ mid-span 1286 Passed (8%)1.60 1.0 D + 0.6 W Total Deflection (in)0.04 @ mid-span 0.25 Passed (L/2541)--1.0 D + 0.6 W Bending/Compression 0.12 1 Passed (12%)1.60 1.0 D + 0.45 W + 0.75 L + 0.75 Lr •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. •This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 7' 7 1/2" System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d (0.113" x 2 1/2") (Toe)2 N/A Base Nails 8d (0.113" x 2 1/2") (Toe)2 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Dead Floor Live Roof Live Wind Vertical Load Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 1 - Point (lb)N/A 881 899 686 -720 Linked from: CB-5, Support 2 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8' 6"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Wind Zone (4), GCpi (+/- 0.18), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 1' 4"16.9 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, C-11 1 piece(s) 4 x 4 DF No.2 Page 111 of 213 Wall Height: 8'Member Height: 7' 7 1/2"Tributary Width: 1' 4" Design Results Actual Allowed Result LDF Load: Combination Slenderness 26 50 Passed (52%)---- Compression (lbs)1049 7551 Passed (14%)1.00 1.0 D + 1.0 L Plate Bearing (lbs)1049 7656 Passed (14%)--1.0 D + 1.0 L Lateral Reaction (lbs)0 ------N/A Lateral Shear (lbs)0 N/A Passed (N/A)--N/A Lateral Moment (ft-lbs)0 @ mid-span N/A Passed (N/A)--N/A Total Deflection (in)0.00 @ mid-span N/A Passed (N/A)--N/A Bending/Compression N/A 1 Passed (N/A)--N/A •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. •This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 7' 7 1/2" System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Dead Floor Live Roof Live Wind Vertical Load Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 1 - Point (lb)N/A 376 673 150 -158 Linked from: CB-6, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, C-12 1 piece(s) 4 x 4 DF No.2 Page 112 of 213 Wall Height: 8'Member Height: 7' 7 1/2"Tributary Width: 1' 4" Design Results Actual Allowed Result LDF Load: Combination [Load Group] Slenderness 26 50 Passed (52%)---- Compression (lbs)2569 7978 Passed (32%)1.60 1.0 D + 0.45 W + 0.75 L + 0.75 Lr [1] Plate Bearing (lbs)2569 7656 Passed (34%)--1.0 D + 0.45 W + 0.75 L + 0.75 Lr [1] Lateral Reaction (lbs)0 ------N/A Lateral Shear (lbs)0 N/A Passed (N/A)--N/A Lateral Moment (ft-lbs)0 @ mid-span N/A Passed (N/A)--N/A Total Deflection (in)0.00 @ mid-span N/A Passed (N/A)--N/A Bending/Compression N/A 1 Passed (N/A)--N/A •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Member connection at both ends must be checked against an uplift of -161. •Applicable calculations are based on NDS. •This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 7' 7 1/2" System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Dead Floor Live Roof Live Wind Vertical Load Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 1 - Point (lb)N/A 1123 647 1145 226/-1284 Linked from: CB-7, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, C-13 1 piece(s) 4 x 4 DF No.2 Page 113 of 213 Wall Height: 8'Member Height: 7' 7 1/2"Tributary Width: 1' 4" Design Results Actual Allowed Result LDF Load: Combination [Load Group] Slenderness 26 50 Passed (52%)---- Compression (lbs)1165 7787 Passed (15%)1.25 1.0 D + 0.75 L + 0.75 Lr [1] Plate Bearing (lbs)1166 7656 Passed (15%)--1.0 D + 0.45 W + 0.75 L + 0.75 Lr [1] Lateral Reaction (lbs)0 ------N/A Lateral Shear (lbs)0 N/A Passed (N/A)--N/A Lateral Moment (ft-lbs)0 @ mid-span N/A Passed (N/A)--N/A Total Deflection (in)0.00 @ mid-span N/A Passed (N/A)--N/A Bending/Compression N/A 1 Passed (N/A)--N/A •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. •This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 7' 7 1/2" System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Dead Floor Live Roof Live Wind Vertical Load Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 1 - Point (lb)N/A 494 538 357 1/-397 Linked from: CB-7, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, C-14 1 piece(s) 4 x 4 DF No.2 Page 114 of 213 Wall Height: 8'Member Height: 7' 7 1/2"Tributary Width: 1' 4" Design Results Actual Allowed Result LDF Load: Combination Slenderness 26 50 Passed (52%)---- Compression (lbs)1122 7551 Passed (15%)1.00 1.0 D + 1.0 L Plate Bearing (lbs)1122 7656 Passed (15%)--1.0 D + 1.0 L Lateral Reaction (lbs)0 ------N/A Lateral Shear (lbs)0 N/A Passed (N/A)--N/A Lateral Moment (ft-lbs)0 @ mid-span N/A Passed (N/A)--N/A Total Deflection (in)0.00 @ mid-span N/A Passed (N/A)--N/A Bending/Compression N/A 1 Passed (N/A)--N/A •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. •This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 7' 7 1/2" System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Dead Floor Live Vertical Load Tributary Width (0.90)(1.00)Comments 1 - Point (lb)N/A 307 815 Linked from: CB-3, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, C-15 1 piece(s) 4 x 4 DF No.2 Page 115 of 213 Wall Height: 8'Member Height: 7' 7 1/2"Tributary Width: 1' 4" Design Results Actual Allowed Result LDF Load: Combination Slenderness 26 50 Passed (52%)---- Compression (lbs)1640 7787 Passed (21%)1.25 1.0 D + 1.0 Lr Plate Bearing (lbs)1640 7656 Passed (21%)--1.0 D + 1.0 Lr Lateral Reaction (lbs)0 ------N/A Lateral Shear (lbs)0 N/A Passed (N/A)--N/A Lateral Moment (ft-lbs)0 @ mid-span N/A Passed (N/A)--N/A Total Deflection (in)0.00 @ mid-span N/A Passed (N/A)--N/A Bending/Compression N/A 1 Passed (N/A)--N/A •Wall deflection criteria: TL (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. •This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 7' 7 1/2" System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Dead Floor Live Roof Live Wind Vertical Load Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 1 - Point (lb)N/A 837 247 803 -822 Linked from: CB-2, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, C-16 1 piece(s) 4 x 4 DF No.2 Page 116 of 213 Wall Height: 8'Member Height: 7' 7 1/2"Tributary Width: 1' 4" Design Results Actual Allowed Result LDF Load: Combination Slenderness 26 50 Passed (52%)---- Compression (lbs)1582 7787 Passed (20%)1.25 1.0 D + 0.75 L + 0.75 Lr Plate Bearing (lbs)1582 7656 Passed (21%)--1.0 D + 0.75 L + 0.75 Lr Lateral Reaction (lbs)0 ------N/A Lateral Shear (lbs)0 N/A Passed (N/A)--N/A Lateral Moment (ft-lbs)0 @ mid-span N/A Passed (N/A)--N/A Total Deflection (in)0.00 @ mid-span N/A Passed (N/A)--N/A Bending/Compression N/A 1 Passed (N/A)--N/A •Wall deflection criteria: TL (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. •This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 7' 7 1/2" System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Dead Floor Live Roof Live Wind Vertical Loads Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 1 - Point (lb)N/A 498 159 546 -589 Linked from: CB-1, Support 2 2 - Point (lb)N/A 194 482 ----Linked from: HDR-10, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, C-17 1 piece(s) 4 x 4 DF No.2 Page 117 of 213 Wall Height: 8'Member Height: 7' 7 1/2"Tributary Width: 1' 4" Design Results Actual Allowed Result LDF Load: Combination Slenderness 26 50 Passed (52%)---- Compression (lbs)1311 7787 Passed (17%)1.25 1.0 D + 1.0 Lr Plate Bearing (lbs)1311 7656 Passed (17%)--1.0 D + 1.0 Lr Lateral Reaction (lbs)52 ----1.60 1.0 D + 0.6 W Lateral Shear (lbs)48 2352 Passed (2%)1.60 1.0 D + 0.6 W Lateral Moment (ft-lbs)98 @ mid-span 1286 Passed (8%)1.60 1.0 D + 0.6 W Total Deflection (in)0.04 @ mid-span 0.25 Passed (L/2541)--1.0 D + 0.6 W Bending/Compression 0.08 1 Passed (8%)1.60 1.0 D + 0.45 W + 0.75 L + 0.75 Lr •Wall deflection criteria: TL (L/360) •Input axial load eccentricity for the design is zero •Member connection at both ends must be checked against an uplift of -9. •Applicable calculations are based on NDS. •This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 7' 7 1/2" System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d (0.113" x 2 1/2") (Toe)2 N/A Base Nails 8d (0.113" x 2 1/2") (Toe)2 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Dead Floor Live Roof Live Wind Vertical Load Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 1 - Point (lb)N/A 655 185 656 -664 Linked from: CB-2, Support 1 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8' 6"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Wind Zone (4), GCpi (+/- 0.18), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 1' 4"16.9 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, C-18 1 piece(s) 4 x 4 DF No.2 Page 118 of 213 Wall Height: 8'Member Height: 7' 7 1/2"Tributary Width: 1' 4" Design Results Actual Allowed Result LDF Load: Combination Slenderness 26 50 Passed (52%)---- Compression (lbs)1304 7551 Passed (17%)1.00 1.0 D + 1.0 L Plate Bearing (lbs)1304 7656 Passed (17%)--1.0 D + 1.0 L Lateral Reaction (lbs)52 ----1.60 1.0 D + 0.6 W Lateral Shear (lbs)48 2352 Passed (2%)1.60 1.0 D + 0.6 W Lateral Moment (ft-lbs)98 @ mid-span 1286 Passed (8%)1.60 1.0 D + 0.6 W Total Deflection (in)0.04 @ mid-span 0.25 Passed (L/2541)--1.0 D + 0.6 W Bending/Compression 0.08 1 Passed (8%)1.60 1.0 D + 0.45 W + 0.75 L + 0.75 S •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. •This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 7' 7 1/2" System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d (0.113" x 2 1/2") (Toe)2 N/A Base Nails 8d (0.113" x 2 1/2") (Toe)2 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Dead Floor Live Vertical Load Tributary Width (0.90)(1.00)Comments 1 - Point (lb)N/A 366 938 Linked from: CB-3, Support 1 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8' 6"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Wind Zone (4), GCpi (+/- 0.18), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 1' 4"16.9 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, C-19 1 piece(s) 4 x 4 DF No.2 Page 119 of 213 S Van Ness Ave Appendix F : Header, Jack and King Stud Design Page 120 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)364 @ 0 3281 (1.50")Passed (11%)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Shear (lbs)251 @ 8 3/4"3045 Passed (8%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)530 @ 3' 3 1/2"2964 Passed (18%)1.00 1.0 D + 1.0 L (All Spans) Vert Live Load Defl. (in)0.006 @ 3' 3 1/2"0.165 Passed (L/999+)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Vert Total Load Defl. (in)0.026 @ 3' 3 1/2"0.219 Passed (L/999+)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Lat Member Reaction (lbs)174 @ 6' 7"N/A Passed (N/A)1.60 1.0 D + 0.6 W Lat Shear (lbs)152 @ 5"4872 Passed (3%)1.60 1.0 D + 0.6 W Lat Moment (Ft-lbs)286 @ mid-span 2425 Passed (12%)1.60 1.0 D + 0.6 W Lat Deflection (in)0.038 @ mid-span 0.219 Passed (L/999+)--1.0 D + 0.6 W Bi-Axial Bending 0.20 1.00 Passed (20%)1.60 1.0 D + 0.45 W + 0.75 L + 0.75 Lr Member Length : 6' 7" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/360). •Lateral deflection criteria: Wind (L/360) •A 0.9% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Roof Live Wind Factored Accessories 1 - Trimmer - DF 1.50"1.50"1.50"278 44 70 -70 364 None 2 - Trimmer - DF 1.50"1.50"1.50"278 44 70 -70 364 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu)End Bearing Points Bottom Edge (Lu)End Bearing Points Lateral Connections Supports Stud Size Stud Material Connector Type/Model Quantity Nailing Left 2X Douglas Fir-Larch Nails 8d (0.113" x 2 1/2") (Toe)2 Right 2X Douglas Fir-Larch Nails 8d (0.113" x 2 1/2") (Toe)2 Dead Floor Live Roof Live Wind Vertical Loads Location Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 0 - Self Weight (PLF)0 to 6' 7"N/A 6.4 ------ 1 - Uniform (PSF)0 to 6' 7"1' 4"12.0 -16.0 -16.0 ROOF 2 - Uniform (PSF)0 to 6' 7"8"6.0 20.0 --CLG 3 - Uniform (PSF)0 to 6' 7"3' 5"17.0 ---WALL • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8' 6"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Wind Zone (4), GCpi (+/- 0.18), Effective Wind Area determined using full member span and trib. width. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 5' 5"16.3 (4'/2)+3'5" Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, HDR-1 1 piece(s) 4 x 8 DF No.2 Page 121 of 213 Wall Height: 7'Member Height: 6' 7 1/2"Tributary Width: 1' Design Results Actual Allowed Result LDF Load: Combination Slenderness 32 50 Passed (64%)---- Compression (lbs)364 2309 Passed (16%)1.25 1.0 D + 0.75 L + 0.75 Lr Plate Bearing (lbs)364 3281 Passed (11%)--1.0 D + 0.75 L + 0.75 Lr Lateral Reaction (lbs)0 ------N/A Lateral Shear (lbs)0 N/A Passed (N/A)--N/A Lateral Moment (ft-lbs)0 @ mid-span N/A Passed (N/A)--N/A Total Deflection (in)0.00 @ mid-span N/A Passed (N/A)--N/A Bending/Compression N/A 1 Passed (N/A)--N/A •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 4' System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Dead Floor Live Roof Live Wind Vertical Load Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 1 - Point (lb)N/A 278 44 70 -70 Linked from: HDR-1, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, JACK-1 1 piece(s) 2 x 4 DF No.2 Page 122 of 213 Wall Height: 8'Member Height: 7' 7 1/2"Tributary Width: 4' 2" Design Results Actual Allowed Result LDF Load: Combination Slenderness 32 50 Passed (64%)---- Compression (lbs)0 2342 Passed (0%)1.60 1.0 D + 0.6 W Plate Bearing (lbs)0 3281 Passed (0%)--1.0 D + 0.6 W Lateral Reaction (lbs)156 ----1.60 1.0 D + 0.6 W Lateral Shear (lbs)144 1008 Passed (14%)1.60 1.0 D + 0.6 W Lateral Moment (ft-lbs)298 @ mid-span 532 Passed (56%)1.60 1.0 D + 0.6 W Total Deflection (in)0.25 @ mid-span 0.25 Passed (L/360)--1.0 D + 0.6 W Bending/Compression 0.56 1 Passed (56%)1.60 1.0 D + 0.6 W •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 4' System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d (0.113" x 2 1/2") (Toe)2 N/A Base Nails 8d (0.113" x 2 1/2") (Toe)2 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Dead Vertical Load Tributary Width (0.90)Comments 1 - Point (lb)N/A - • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8' 6"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Wind Zone (4), GCpi (+/- 0.18), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 4' 2"16.4 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, KING-1 1 piece(s) 2 x 4 DF No.2 Page 123 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)174 @ 0 3281 (1.50")Passed (5%)--1.0 D + 1.0 L (All Spans) Shear (lbs)112 @ 7"2310 Passed (5%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)142 @ 1' 7 1/2"1715 Passed (8%)1.00 1.0 D + 1.0 L (All Spans) Vert Live Load Defl. (in)0.000 @ 1' 7 1/2"0.108 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Vert Total Load Defl. (in)0.003 @ 1' 7 1/2"0.162 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Lat Member Reaction (lbs)137 @ 3' 3"N/A Passed (N/A)1.60 1.0 D + 0.6 W Lat Shear (lbs)102 @ 5"3696 Passed (3%)1.60 1.0 D + 0.6 W Lat Moment (Ft-lbs)111 @ mid-span 1839 Passed (6%)1.60 1.0 D + 0.6 W Lat Deflection (in)0.005 @ mid-span 0.108 Passed (L/999+)--1.0 D + 0.6 W Bi-Axial Bending 0.11 1.00 Passed (11%)1.60 1.0 D + 0.6 W Member Length : 3' 3" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Lateral deflection criteria: Wind (L/360) •A 0.3% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Factored Accessories 1 - Trimmer - DF 1.50"1.50"1.50"153 22 174 None 2 - Trimmer - DF 1.50"1.50"1.50"153 22 174 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu)End Bearing Points Bottom Edge (Lu)End Bearing Points Lateral Connections Supports Stud Size Stud Material Connector Type/Model Quantity Nailing Left 2X Douglas Fir-Larch Nails 8d (0.113" x 2 1/2") (Toe)2 Right 2X Douglas Fir-Larch Nails 8d (0.113" x 2 1/2") (Toe)2 Dead Floor Live Vertical Loads Location Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 3' 3"N/A 4.9 -- 1 - Uniform (PSF)0 to 3' 3"8"6.0 20.0 CLG 2 - Uniform (PSF)0 to 3' 3"5'17.0 -WALL • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8' 6"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Wind Zone (4), GCpi (+/- 0.18), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 8' 6"16.5 (7'/2)+5' Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, HDR-2 1 piece(s) 4 x 6 DF No.2 Page 124 of 213 Wall Height: 7'Member Height: 6' 7 1/2"Tributary Width: 1' Design Results Actual Allowed Result LDF Load: Combination Slenderness 32 50 Passed (64%)---- Compression (lbs)175 2269 Passed (8%)1.00 1.0 D + 1.0 L Plate Bearing (lbs)175 3281 Passed (5%)--1.0 D + 1.0 L Lateral Reaction (lbs)0 ------N/A Lateral Shear (lbs)0 N/A Passed (N/A)--N/A Lateral Moment (ft-lbs)0 @ mid-span N/A Passed (N/A)--N/A Total Deflection (in)0.00 @ mid-span N/A Passed (N/A)--N/A Bending/Compression N/A 1 Passed (N/A)--N/A •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 4' System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Dead Floor Live Vertical Load Tributary Width (0.90)(1.00)Comments 1 - Point (lb)N/A 153 22 Linked from: HDR-2, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, JACK-2 1 piece(s) 2 x 4 DF No.2 Page 125 of 213 Wall Height: 8'Member Height: 7' 7 1/2"Tributary Width: 2' 6" Design Results Actual Allowed Result LDF Load: Combination Slenderness 32 50 Passed (64%)---- Compression (lbs)0 2342 Passed (0%)1.60 1.0 D + 0.6 W Plate Bearing (lbs)0 3281 Passed (0%)--1.0 D + 0.6 W Lateral Reaction (lbs)97 ----1.60 1.0 D + 0.6 W Lateral Shear (lbs)89 1008 Passed (9%)1.60 1.0 D + 0.6 W Lateral Moment (ft-lbs)184 @ mid-span 532 Passed (35%)1.60 1.0 D + 0.6 W Total Deflection (in)0.16 @ mid-span 0.25 Passed (L/581)--1.0 D + 0.6 W Bending/Compression 0.35 1 Passed (35%)1.60 1.0 D + 0.6 W •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 4' System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d (0.113" x 2 1/2") (Toe)2 N/A Base Nails 8d (0.113" x 2 1/2") (Toe)2 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Dead Vertical Load Tributary Width (0.90)Comments 1 - Point (lb)N/A - • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8' 6"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Wind Zone (4), GCpi (+/- 0.18), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 2' 6"16.9 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, KING-2 1 piece(s) 2 x 4 DF No.2 Page 126 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)309 @ 0 3281 (1.50")Passed (9%)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Shear (lbs)217 @ 7"2310 Passed (9%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)387 @ 2' 10"1711 Passed (23%)1.00 1.0 D + 1.0 L (All Spans) Vert Live Load Defl. (in)0.008 @ 2' 10"0.142 Passed (L/999+)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Vert Total Load Defl. (in)0.033 @ 2' 10"0.189 Passed (L/999+)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Lat Member Reaction (lbs)151 @ 5' 8"N/A Passed (N/A)1.60 1.0 D + 0.6 W Lat Shear (lbs)129 @ 5"3696 Passed (3%)1.60 1.0 D + 0.6 W Lat Moment (Ft-lbs)214 @ mid-span 1839 Passed (12%)1.60 1.0 D + 0.6 W Lat Deflection (in)0.028 @ mid-span 0.189 Passed (L/999+)--1.0 D + 0.6 W Bi-Axial Bending 0.23 1.00 Passed (23%)1.60 1.0 D + 0.45 W + 0.75 L + 0.75 Lr Member Length : 5' 8" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/360). •Lateral deflection criteria: Wind (L/360) •A 0.5% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Roof Live Wind Factored Accessories 1 - Trimmer - DF 1.50"1.50"1.50"235 38 60 -60 309 None 2 - Trimmer - DF 1.50"1.50"1.50"235 38 60 -60 309 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu)End Bearing Points Bottom Edge (Lu)End Bearing Points Lateral Connections Supports Stud Size Stud Material Connector Type/Model Quantity Nailing Left 2X Douglas Fir-Larch Nails 8d (0.113" x 2 1/2") (Toe)2 Right 2X Douglas Fir-Larch Nails 8d (0.113" x 2 1/2") (Toe)2 Dead Floor Live Roof Live Wind Vertical Loads Location Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 0 - Self Weight (PLF)0 to 5' 8"N/A 4.9 ------ 1 - Uniform (PSF)0 to 5' 8"1' 4"12.0 -16.0 -16.0 ROOF 2 - Uniform (PSF)0 to 5' 8"8"6.0 20.0 --CLG 3 - Uniform (PSF)0 to 5' 8"3' 5"17.0 ---WALL • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8' 6"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Wind Zone (4), GCpi (+/- 0.18), Effective Wind Area determined using full member span and trib. width. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 5' 5"16.4 (4'/2)+3'5" Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, HDR-3 1 piece(s) 4 x 6 DF No.2 Page 127 of 213 Wall Height: 7'Member Height: 6' 7 1/2"Tributary Width: 1' Design Results Actual Allowed Result LDF Load: Combination Slenderness 32 50 Passed (64%)---- Compression (lbs)309 2309 Passed (13%)1.25 1.0 D + 0.75 L + 0.75 Lr Plate Bearing (lbs)309 3281 Passed (9%)--1.0 D + 0.75 L + 0.75 Lr Lateral Reaction (lbs)0 ------N/A Lateral Shear (lbs)0 N/A Passed (N/A)--N/A Lateral Moment (ft-lbs)0 @ mid-span N/A Passed (N/A)--N/A Total Deflection (in)0.00 @ mid-span N/A Passed (N/A)--N/A Bending/Compression N/A 1 Passed (N/A)--N/A •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 4' System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Dead Floor Live Roof Live Wind Vertical Load Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 1 - Point (lb)N/A 235 38 60 -60 Linked from: HDR-3, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, JACK-3 1 piece(s) 2 x 4 DF No.2 Page 128 of 213 Wall Height: 8'Member Height: 7' 7 1/2"Tributary Width: 3' 6" Design Results Actual Allowed Result LDF Load: Combination Slenderness 32 50 Passed (64%)---- Compression (lbs)0 2342 Passed (0%)1.60 1.0 D + 0.6 W Plate Bearing (lbs)0 3281 Passed (0%)--1.0 D + 0.6 W Lateral Reaction (lbs)133 ----1.60 1.0 D + 0.6 W Lateral Shear (lbs)123 1008 Passed (12%)1.60 1.0 D + 0.6 W Lateral Moment (ft-lbs)253 @ mid-span 532 Passed (48%)1.60 1.0 D + 0.6 W Total Deflection (in)0.22 @ mid-span 0.25 Passed (L/423)--1.0 D + 0.6 W Bending/Compression 0.48 1 Passed (48%)1.60 1.0 D + 0.6 W •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 4' System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d (0.113" x 2 1/2") (Toe)2 N/A Base Nails 8d (0.113" x 2 1/2") (Toe)2 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Dead Vertical Load Tributary Width (0.90)Comments 1 - Point (lb)N/A - • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8' 6"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Wind Zone (4), GCpi (+/- 0.18), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 3' 6"16.6 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, KING-3 1 piece(s) 2 x 4 DF No.2 Page 129 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)462 @ 0 3281 (1.50")Passed (14%)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Shear (lbs)296 @ 7"2888 Passed (10%)1.25 1.0 D + 0.75 L + 0.75 Lr (All Spans) Moment (Ft-lbs)375 @ 1' 7 1/2"2142 Passed (18%)1.25 1.0 D + 0.75 L + 0.75 Lr (All Spans) Vert Live Load Defl. (in)0.005 @ 1' 7 1/2"0.108 Passed (L/999+)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Vert Total Load Defl. (in)0.009 @ 1' 7 1/2"0.162 Passed (L/999+)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Lat Member Reaction (lbs)52 @ 3' 3"N/A Passed (N/A)1.60 1.0 D + 0.6 W Lat Shear (lbs)38 @ 5"3696 Passed (1%)1.60 1.0 D + 0.6 W Lat Moment (Ft-lbs)42 @ mid-span 1839 Passed (2%)1.60 1.0 D + 0.6 W Lat Deflection (in)0.002 @ mid-span 0.108 Passed (L/999+)--1.0 D + 0.6 W Bi-Axial Bending 0.13 1.00 Passed (13%)1.60 1.0 D + 0.45 W + 0.75 L + 0.75 Lr Member Length : 3' 3" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Lateral deflection criteria: Wind (L/360) •A 0.4% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Roof Live Wind Factored Accessories 1 - Trimmer - DF 1.50"1.50"1.50"218 147 177 -177 462 None 2 - Trimmer - DF 1.50"1.50"1.50"218 147 177 -177 462 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu)End Bearing Points Bottom Edge (Lu)End Bearing Points Lateral Connections Supports Stud Size Stud Material Connector Type/Model Quantity Nailing Left 2X Douglas Fir-Larch Nails 8d (0.113" x 2 1/2") (Toe)2 Right 2X Douglas Fir-Larch Nails 8d (0.113" x 2 1/2") (Toe)2 Dead Floor Live Roof Live Wind Vertical Loads Location Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 0 - Self Weight (PLF)0 to 3' 3"N/A 4.9 ------ 1 - Uniform (PSF)0 to 3' 3"1'17.0 ---WALL 2 - Uniform (PLF)0 to 3' 3"N/A 27.0 90.8 --Linked from: CJ-1, Support 1 3 - Uniform (PLF)0 to 3' 3"N/A 85.5 -108.8 -108.8 Linked from: RR-1, Support 1 Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 3'17.6 (4'/2)+1' Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, HDR-4 1 piece(s) 4 x 6 DF No.2 Page 130 of 213 Wall Height: 7'Member Height: 6' 7 1/2"Tributary Width: 1' Design Results Actual Allowed Result LDF Load: Combination Slenderness 32 50 Passed (64%)---- Compression (lbs)461 2309 Passed (20%)1.25 1.0 D + 0.75 L + 0.75 Lr Plate Bearing (lbs)461 3281 Passed (14%)--1.0 D + 0.75 L + 0.75 Lr Lateral Reaction (lbs)0 ------N/A Lateral Shear (lbs)0 N/A Passed (N/A)--N/A Lateral Moment (ft-lbs)0 @ mid-span N/A Passed (N/A)--N/A Total Deflection (in)0.00 @ mid-span N/A Passed (N/A)--N/A Bending/Compression N/A 1 Passed (N/A)--N/A •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 4' System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Dead Floor Live Roof Live Wind Vertical Load Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 1 - Point (lb)N/A 218 147 177 -177 Linked from: HDR-4, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, JACK-4 1 piece(s) 2 x 4 DF No.2 Page 131 of 213 Wall Height: 8'Member Height: 7' 7 1/2"Tributary Width: 2' 6" Design Results Actual Allowed Result LDF Load: Combination Slenderness 32 50 Passed (64%)---- Compression (lbs)0 2342 Passed (0%)1.60 1.0 D + 0.6 W Plate Bearing (lbs)0 3281 Passed (0%)--1.0 D + 0.6 W Lateral Reaction (lbs)97 ----1.60 1.0 D + 0.6 W Lateral Shear (lbs)89 1008 Passed (9%)1.60 1.0 D + 0.6 W Lateral Moment (ft-lbs)184 @ mid-span 532 Passed (35%)1.60 1.0 D + 0.6 W Total Deflection (in)0.16 @ mid-span 0.25 Passed (L/581)--1.0 D + 0.6 W Bending/Compression 0.35 1 Passed (35%)1.60 1.0 D + 0.6 W •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 4' System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d (0.113" x 2 1/2") (Toe)2 N/A Base Nails 8d (0.113" x 2 1/2") (Toe)2 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Dead Vertical Load Tributary Width (0.90)Comments 1 - Point (lb)N/A - • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8' 6"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Wind Zone (4), GCpi (+/- 0.18), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 2' 6"16.9 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, KING-4 1 piece(s) 2 x 4 DF No.2 Page 132 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)246 @ 0 3281 (1.50")Passed (7%)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Shear (lbs)118 @ 7"2888 Passed (4%)1.25 1.0 D + 0.75 L + 0.75 Lr (All Spans) Moment (Ft-lbs)138 @ 1' 1 1/2"2145 Passed (6%)1.25 1.0 D + 0.75 L + 0.75 Lr (All Spans) Vert Live Load Defl. (in)0.001 @ 1' 1 1/2"0.075 Passed (L/999+)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Vert Total Load Defl. (in)0.002 @ 1' 1 1/2"0.112 Passed (L/999+)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Lat Member Reaction (lbs)30 @ 2' 3"N/A Passed (N/A)1.60 1.0 D + 0.6 W Lat Shear (lbs)19 @ 5"3696 Passed (1%)1.60 1.0 D + 0.6 W Lat Moment (Ft-lbs)17 @ mid-span 1839 Passed (1%)1.60 1.0 D + 0.6 W Lat Deflection (in)0.000 @ mid-span 0.075 Passed (L/999+)--1.0 D + 0.6 W Bi-Axial Bending 0.05 1.00 Passed (5%)1.60 1.0 D + 0.45 W + 0.75 L + 0.75 Lr Member Length : 2' 3" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Lateral deflection criteria: Wind (L/360) •A 0.3% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Roof Live Wind Factored Accessories 1 - Trimmer - DF 1.50"1.50"1.50"122 68 98 -98 246 None 2 - Trimmer - DF 1.50"1.50"1.50"122 68 98 -98 246 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu)End Bearing Points Bottom Edge (Lu)End Bearing Points Lateral Connections Supports Stud Size Stud Material Connector Type/Model Quantity Nailing Left 2X Douglas Fir-Larch Nails 8d (0.113" x 2 1/2") (Toe)2 Right 2X Douglas Fir-Larch Nails 8d (0.113" x 2 1/2") (Toe)2 Dead Floor Live Roof Live Wind Vertical Loads Location Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 0 - Self Weight (PLF)0 to 2' 3"N/A 4.9 ------ 1 - Uniform (PSF)0 to 2' 3"1'17.0 ---WALL 2 - Uniform (PLF)0 to 2' 3"N/A 68.3 -87.0 -87.0 Linked from: RR-4, Support 1 3 - Uniform (PLF)0 to 2' 3"N/A 18.0 60.0 --Linked from: CJ-8, Support 2 Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 2' 6"17.6 (3'/2)+1' Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, HDR-5 1 piece(s) 4 x 6 DF No.2 Page 133 of 213 Wall Height: 7'Member Height: 6' 7 1/2"Tributary Width: 1' Design Results Actual Allowed Result LDF Load: Combination Slenderness 32 50 Passed (64%)---- Compression (lbs)247 2309 Passed (11%)1.25 1.0 D + 0.75 L + 0.75 Lr Plate Bearing (lbs)247 3281 Passed (8%)--1.0 D + 0.75 L + 0.75 Lr Lateral Reaction (lbs)0 ------N/A Lateral Shear (lbs)0 N/A Passed (N/A)--N/A Lateral Moment (ft-lbs)0 @ mid-span N/A Passed (N/A)--N/A Total Deflection (in)0.00 @ mid-span N/A Passed (N/A)--N/A Bending/Compression N/A 1 Passed (N/A)--N/A •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 4' System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Dead Floor Live Roof Live Wind Vertical Load Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 1 - Point (lb)N/A 122 68 98 -98 Linked from: HDR-5, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, JACK-5 1 piece(s) 2 x 4 DF No.2 Page 134 of 213 Wall Height: 8'Member Height: 7' 7 1/2"Tributary Width: 2' Design Results Actual Allowed Result LDF Load: Combination Slenderness 32 50 Passed (64%)---- Compression (lbs)0 2342 Passed (0%)1.60 1.0 D + 0.6 W Plate Bearing (lbs)0 3281 Passed (0%)--1.0 D + 0.6 W Lateral Reaction (lbs)77 ----1.60 1.0 D + 0.6 W Lateral Shear (lbs)71 1008 Passed (7%)1.60 1.0 D + 0.6 W Lateral Moment (ft-lbs)147 @ mid-span 532 Passed (28%)1.60 1.0 D + 0.6 W Total Deflection (in)0.13 @ mid-span 0.25 Passed (L/726)--1.0 D + 0.6 W Bending/Compression 0.28 1 Passed (28%)1.60 1.0 D + 0.6 W •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 4' System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d (0.113" x 2 1/2") (Toe)2 N/A Base Nails 8d (0.113" x 2 1/2") (Toe)2 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Dead Vertical Load Tributary Width (0.90)Comments 1 - Point (lb)N/A - • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8' 6"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Wind Zone (4), GCpi (+/- 0.18), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 2'16.9 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, KING-5 1 piece(s) 2 x 4 DF No.2 Page 135 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1389 @ 6' 7"3281 (1.50")Passed (42%)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Shear (lbs)996 @ 5' 10 1/4"3045 Passed (33%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1754 @ 3' 6 1/16"2964 Passed (59%)1.00 1.0 D + 1.0 L (All Spans) Vert Live Load Defl. (in)0.050 @ 3' 4 1/4"0.165 Passed (L/999+)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Vert Total Load Defl. (in)0.091 @ 3' 4 3/8"0.219 Passed (L/871)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Lat Member Reaction (lbs)100 @ 6' 7"N/A Passed (N/A)1.60 1.0 D + 0.6 W Lat Shear (lbs)87 @ 5"4872 Passed (2%)1.60 1.0 D + 0.6 W Lat Moment (Ft-lbs)165 @ mid-span 2425 Passed (7%)1.60 1.0 D + 0.6 W Lat Deflection (in)0.022 @ mid-span 0.219 Passed (L/999+)--1.0 D + 0.6 W Bi-Axial Bending 0.42 1.00 Passed (42%)1.60 1.0 D + 0.45 W + 0.75 L + 0.75 Lr Member Length : 6' 7" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/360). •Wall deflection criteria: TL (L/360) •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Roof Live Wind Factored Accessories 1 - Trimmer - DF 1.50"1.50"1.50"489 458 336 -339 1085 None 2 - Trimmer - DF 1.50"1.50"1.50"635 539 466 -479 1389 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu)End Bearing Points Bottom Edge (Lu)End Bearing Points Lateral Connections Supports Stud Size Stud Material Connector Type/Model Quantity Nailing Left 2X Douglas Fir-Larch Nails 8d (0.113" x 2 1/2") (Toe)2 Right 2X Douglas Fir-Larch Nails 8d (0.113" x 2 1/2") (Toe)2 Dead Floor Live Roof Live Wind Vertical Loads Location Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 0 - Self Weight (PLF)0 to 6' 7"N/A 6.4 ------ 1 - Uniform (PSF)0 to 6' 7"1'17.0 ------WALL 2 - Uniform (PLF)2' 1" to 6' 7"N/A 35.3 117.0 ----Linked from: CJ-6, Support 1 3 - Uniform (PLF)0 to 2' 1"N/A 28.5 94.5 ----Linked from: CJ-9, Support 1 4 - Point (lb)2' 1"N/A 39 114 ----Linked from: CB-13, Support 1 5 - Uniform (PLF)0 to 6' 7"N/A 68.3 --87.0 -87.0 Linked from: RR-4, Support 1 6 - Point (lb)5' 2"N/A 264 159 229 -246 Linked from: CB-1, Support 1 Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, HDR-6 1 piece(s) 4 x 8 DF No.2 Page 136 of 213 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8' 6"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Wind Zone (4), GCpi (+/- 0.18), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 3'16.9 (4'/2)+1' Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Page 137 of 213 Wall Height: 7'Member Height: 6' 7 1/2"Tributary Width: 1' Design Results Actual Allowed Result LDF Load: Combination Slenderness 32 50 Passed (64%)---- Compression (lbs)1389 2309 Passed (60%)1.25 1.0 D + 0.75 L + 0.75 Lr Plate Bearing (lbs)1389 3281 Passed (42%)--1.0 D + 0.75 L + 0.75 Lr Lateral Reaction (lbs)0 ------N/A Lateral Shear (lbs)0 N/A Passed (N/A)--N/A Lateral Moment (ft-lbs)0 @ mid-span N/A Passed (N/A)--N/A Total Deflection (in)0.00 @ mid-span N/A Passed (N/A)--N/A Bending/Compression N/A 1 Passed (N/A)--N/A •Wall deflection criteria: TL (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 4' System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Dead Floor Live Roof Live Wind Vertical Load Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 1 - Point (lb)N/A 635 539 466 -479 Linked from: HDR-6, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, JACK-6 1 piece(s) 2 x 4 DF No.2 Page 138 of 213 Wall Height: 8'Member Height: 7' 7 1/2"Tributary Width: 4' 2" Design Results Actual Allowed Result LDF Load: Combination Slenderness 32 50 Passed (64%)---- Compression (lbs)0 2342 Passed (0%)1.60 1.0 D + 0.6 W Plate Bearing (lbs)0 3281 Passed (0%)--1.0 D + 0.6 W Lateral Reaction (lbs)156 ----1.60 1.0 D + 0.6 W Lateral Shear (lbs)144 1008 Passed (14%)1.60 1.0 D + 0.6 W Lateral Moment (ft-lbs)298 @ mid-span 532 Passed (56%)1.60 1.0 D + 0.6 W Total Deflection (in)0.25 @ mid-span 0.25 Passed (L/360)--1.0 D + 0.6 W Bending/Compression 0.56 1 Passed (56%)1.60 1.0 D + 0.6 W •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 4' System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d (0.113" x 2 1/2") (Toe)2 N/A Base Nails 8d (0.113" x 2 1/2") (Toe)2 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Dead Vertical Load Tributary Width (0.90)Comments 1 - Point (lb)N/A - • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8' 6"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Wind Zone (4), GCpi (+/- 0.18), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 4' 2"16.4 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, KING-6 1 piece(s) 2 x 4 DF No.2 Page 139 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)146 @ 0 3281 (1.50")Passed (4%)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Shear (lbs)64 @ 7"2310 Passed (3%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)74 @ 1' 1 1/2"1717 Passed (4%)1.00 1.0 D + 1.0 L (All Spans) Vert Live Load Defl. (in)0.000 @ 1' 1 1/2"0.075 Passed (L/999+)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Vert Total Load Defl. (in)0.001 @ 1' 1 1/2"0.112 Passed (L/999+)--1.0 D + 0.75 L + 0.75 Lr (All Spans) Lat Member Reaction (lbs)72 @ 2' 3"N/A Passed (N/A)1.60 1.0 D + 0.6 W Lat Shear (lbs)45 @ 5"3696 Passed (1%)1.60 1.0 D + 0.6 W Lat Moment (Ft-lbs)40 @ mid-span 1839 Passed (2%)1.60 1.0 D + 0.6 W Lat Deflection (in)0.001 @ mid-span 0.075 Passed (L/999+)--1.0 D + 0.6 W Bi-Axial Bending 0.04 1.00 Passed (4%)1.60 1.0 D + 0.45 W + 0.75 L + 0.75 Lr Member Length : 2' 3" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Lateral deflection criteria: Wind (L/360) •A 0.2% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Roof Live Wind Factored Accessories 1 - Trimmer - DF 1.50"1.50"1.50"117 15 24 -24 146 None 2 - Trimmer - DF 1.50"1.50"1.50"117 15 24 -24 146 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu)End Bearing Points Bottom Edge (Lu)End Bearing Points Lateral Connections Supports Stud Size Stud Material Connector Type/Model Quantity Nailing Left 2X Douglas Fir-Larch Nails 8d (0.113" x 2 1/2") (Toe)2 Right 2X Douglas Fir-Larch Nails 8d (0.113" x 2 1/2") (Toe)2 Dead Floor Live Roof Live Wind Vertical Loads Location Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 0 - Self Weight (PLF)0 to 2' 3"N/A 4.9 ------ 1 - Uniform (PSF)0 to 2' 3"4' 8"17.0 ---WALL 2 - Uniform (PSF)0 to 2' 3"8"6.0 20.0 --CLG 3 - Uniform (PSF)0 to 2' 3"1' 4"12.0 -16.0 -16.0 ROOF • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8' 6"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Wind Zone (4), GCpi (+/- 0.18), Effective Wind Area determined using full member span and trib. width. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 6' 2"17.3 (3'/2)+4'8" Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, HDR-7 1 piece(s) 4 x 6 DF No.2 Page 140 of 213 Wall Height: 7'Member Height: 6' 7 1/2"Tributary Width: 1' Design Results Actual Allowed Result LDF Load: Combination Slenderness 32 50 Passed (64%)---- Compression (lbs)146 2309 Passed (6%)1.25 1.0 D + 0.75 L + 0.75 Lr Plate Bearing (lbs)146 3281 Passed (4%)--1.0 D + 0.75 L + 0.75 Lr Lateral Reaction (lbs)0 ------N/A Lateral Shear (lbs)0 N/A Passed (N/A)--N/A Lateral Moment (ft-lbs)0 @ mid-span N/A Passed (N/A)--N/A Total Deflection (in)0.00 @ mid-span N/A Passed (N/A)--N/A Bending/Compression N/A 1 Passed (N/A)--N/A •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 4' System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Dead Floor Live Roof Live Wind Vertical Load Tributary Width (0.90)(1.00)(1.25)(1.60)Comments 1 - Point (lb)N/A 117 15 24 -24 Linked from: HDR-7, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, JACK-7 1 piece(s) 2 x 4 DF No.2 Page 141 of 213 Wall Height: 8'Member Height: 7' 7 1/2"Tributary Width: 2' Design Results Actual Allowed Result LDF Load: Combination Slenderness 32 50 Passed (64%)---- Compression (lbs)0 2342 Passed (0%)1.60 1.0 D + 0.6 W Plate Bearing (lbs)0 3281 Passed (0%)--1.0 D + 0.6 W Lateral Reaction (lbs)77 ----1.60 1.0 D + 0.6 W Lateral Shear (lbs)71 1008 Passed (7%)1.60 1.0 D + 0.6 W Lateral Moment (ft-lbs)147 @ mid-span 532 Passed (28%)1.60 1.0 D + 0.6 W Total Deflection (in)0.13 @ mid-span 0.25 Passed (L/726)--1.0 D + 0.6 W Bending/Compression 0.28 1 Passed (28%)1.60 1.0 D + 0.6 W •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 4' System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d (0.113" x 2 1/2") (Toe)2 N/A Base Nails 8d (0.113" x 2 1/2") (Toe)2 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Dead Vertical Load Tributary Width (0.90)Comments 1 - Point (lb)N/A - • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8' 6"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Wind Zone (4), GCpi (+/- 0.18), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Tributary Width (1.60)Comments 1 - Uniform (PSF)Full Length 2'16.9 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, KING-7 1 piece(s) 2 x 4 DF No.2 Page 142 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)732 @ 0 3281 (1.50")Passed (22%)--1.0 D + 1.0 L (All Spans) Shear (lbs)638 @ 3' 10"2310 Passed (28%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)865 @ 1' 11"1713 Passed (51%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.026 @ 2' 2 5/16"0.147 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.037 @ 2' 2 5/16"0.221 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Member Length : 4' 5" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •A 0.4% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Factored Accessories 1 - Trimmer - DF 1.50"1.50"1.50"210 522 732 None 2 - Trimmer - DF 1.50"1.50"1.50"221 500 721 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu)End Bearing Points Bottom Edge (Lu)End Bearing Points Dead Floor Live Vertical Loads Location Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 4' 5"N/A 4.9 -- 1 - Uniform (PSF)0 to 4' 5"1'10.0 -WALL 2 - Uniform (PLF)0 to 4' 5"N/A 29.3 98.3 Linked from: CJ-4, Support 2 3 - Uniform (PLF)0 to 1' 11"N/A 34.5 115.5 Linked from: CJ-5, Support 1 4 - Point (lb)1' 11"N/A 85 183 Linked from: CB-11, Support 1 5 - Point (lb)3' 9"N/A 85 183 Linked from: CB-11, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, HDR-8 1 piece(s) 4 x 6 DF No.2 Page 143 of 213 Wall Height: 7'Member Height: 6' 7 1/2"Tributary Width: 1' Design Results Actual Allowed Result LDF Load: Combination Slenderness 32 50 Passed (64%)---- Compression (lbs)721 2269 Passed (32%)1.00 1.0 D + 1.0 L Plate Bearing (lbs)721 3281 Passed (22%)--1.0 D + 1.0 L Lateral Reaction (lbs)0 ------N/A Lateral Shear (lbs)0 N/A Passed (N/A)--N/A Lateral Moment (ft-lbs)0 @ mid-span N/A Passed (N/A)--N/A Total Deflection (in)0.00 @ mid-span N/A Passed (N/A)--N/A Bending/Compression N/A 1 Passed (N/A)--N/A •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 4' System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Dead Floor Live Vertical Load Tributary Width (0.90)(1.00)Comments 1 - Point (lb)N/A 221 500 Linked from: HDR-8, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, JACK-8 1 piece(s) 2 x 4 DF No.2 Page 144 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)414 @ 0 3281 (1.50")Passed (13%)--1.0 D + 1.0 L (All Spans) Shear (lbs)244 @ 7"2310 Passed (11%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)293 @ 1' 5"1716 Passed (17%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.004 @ 1' 5"0.094 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.005 @ 1' 5"0.142 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Member Length : 2' 10" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •A 0.3% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Factored Accessories 1 - Trimmer - DF 1.50"1.50"1.50"111 303 414 None 2 - Trimmer - DF 1.50"1.50"1.50"111 303 414 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu)End Bearing Points Bottom Edge (Lu)End Bearing Points Dead Floor Live Vertical Loads Location Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 2' 10"N/A 4.9 -- 1 - Uniform (PSF)0 to 2' 10"1'10.0 -WALL 2 - Uniform (PLF)0 to 2' 10"N/A 29.3 98.3 Linked from: CJ-4, Support 2 3 - Uniform (PLF)0 to 2' 10"N/A 34.5 115.5 Linked from: CJ-5, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, HDR-9 1 piece(s) 4 x 6 DF No.2 Page 145 of 213 Wall Height: 7'Member Height: 6' 7 1/2"Tributary Width: 1' Design Results Actual Allowed Result LDF Load: Combination Slenderness 32 50 Passed (64%)---- Compression (lbs)414 2269 Passed (18%)1.00 1.0 D + 1.0 L Plate Bearing (lbs)414 3281 Passed (13%)--1.0 D + 1.0 L Lateral Reaction (lbs)0 ------N/A Lateral Shear (lbs)0 N/A Passed (N/A)--N/A Lateral Moment (ft-lbs)0 @ mid-span N/A Passed (N/A)--N/A Total Deflection (in)0.00 @ mid-span N/A Passed (N/A)--N/A Bending/Compression N/A 1 Passed (N/A)--N/A •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 4' System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Dead Floor Live Vertical Load Tributary Width (0.90)(1.00)Comments 1 - Point (lb)N/A 111 303 Linked from: HDR-9, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, JACK-9 1 piece(s) 2 x 4 DF No.2 Page 146 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)676 @ 5' 2"3281 (1.50")Passed (21%)--1.0 D + 1.0 L (All Spans) Shear (lbs)537 @ 4' 7"2310 Passed (23%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)957 @ 2' 4"1712 Passed (56%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.040 @ 2' 7 1/16"0.172 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.057 @ 2' 7"0.258 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Member Length : 5' 2" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Factored Accessories 1 - Trimmer - DF 1.50"1.50"1.50"172 390 562 None 2 - Trimmer - DF 1.50"1.50"1.50"194 482 676 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu)End Bearing Points Bottom Edge (Lu)End Bearing Points Dead Floor Live Vertical Loads Location Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 5' 2"N/A 4.9 -- 1 - Uniform (PSF)0 to 5' 2"1'10.0 --WALL 2 - Uniform (PLF)2' to 5' 2"N/A 34.5 114.0 Linked from: CJ-6, Support 2 3 - Point (lb)2'N/A 91 212 Linked from: CB-13, Support 2 4 - Uniform (PLF)0 to 5' 2"N/A 17.3 57.8 Linked from: CJ-8, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, HDR-10 1 piece(s) 4 x 6 DF No.2 Page 147 of 213 Wall Height: 7'Member Height: 6' 7 1/2"Tributary Width: 1' Design Results Actual Allowed Result LDF Load: Combination Slenderness 32 50 Passed (64%)---- Compression (lbs)562 2269 Passed (25%)1.00 1.0 D + 1.0 L Plate Bearing (lbs)562 3281 Passed (17%)--1.0 D + 1.0 L Lateral Reaction (lbs)0 ------N/A Lateral Shear (lbs)0 N/A Passed (N/A)--N/A Lateral Moment (ft-lbs)0 @ mid-span N/A Passed (N/A)--N/A Total Deflection (in)0.00 @ mid-span N/A Passed (N/A)--N/A Bending/Compression N/A 1 Passed (N/A)--N/A •Wall deflection criteria: TL (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 4' System : Wall Member Type : Column Building Code : IBC 2021 Design Methodology : ASD Dead Floor Live Vertical Load Tributary Width (0.90)(1.00)Comments 1 - Point (lb)N/A 172 390 Linked from: HDR-10, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, JACK-10 1 piece(s) 2 x 4 DF No.2 Page 148 of 213 S Van Ness Ave Appendix G : Joist Design Page 149 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)211 @ 12' 3 1/2"1406 (1.50")Passed (15%)--1.0 D + 1.0 Lr (Alt Spans) Shear (lbs)189 @ 11' 8 5/8"1631 Passed (12%)1.25 1.0 D + 1.0 Lr (Alt Spans) Moment (Ft-lbs)584 @ 6' 9 1/8"1700 Passed (34%)1.25 1.0 D + 1.0 Lr (Alt Spans) Live Load Defl. (in)0.107 @ 6' 8 3/4"0.392 Passed (L/999+)--1.0 D + 1.0 Lr (Alt Spans) Total Load Defl. (in)0.190 @ 6' 8 13/16"0.587 Passed (L/743)--1.0 D + 1.0 Lr (Alt Spans) Member Length : 13' 1 7/8" System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 4/12 •Deflection criteria: LL (L/360) and TL (L/240). •Overhang deflection criteria: LL (2L/360) and TL (2L/240). •A 15% increase in the moment capacity has been added to account for repetitive member usage. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Wind Factored Accessories 1 - Beveled Plate - DF 3.50"3.50"1.50"114 145 -145 259/-18 Blocking 2 - Hanger on 7 1/4" DF beam 1.50"Hanger¹1.50"95 121 -122 216/-16 See note ¹ •Dimensions for lateral bracing intervals are measured along the length of the member for sloped conditions. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger LRU26Z 1.94"N/A 4-10dx1.5 5-10d •Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Roof Live Wind Vertical Load Location (Side)Spacing (0.90)(1.25)(1.60)Comments 1 - Uniform (PSF)0 to 12' 5"16"12.0 16.0 -16.0 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED ROOF, RR-1 1 piece(s) 2 x 8 DF No.2 @ 16" OC Page 150 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)212 @ 11' 3 1/2"1406 (1.50")Passed (15%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)190 @ 10' 8 5/8"1631 Passed (12%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)587 @ 5' 9"1700 Passed (35%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.106 @ 5' 9"0.389 Passed (L/999+)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.189 @ 5' 9"0.584 Passed (L/741)--1.0 D + 1.0 Lr (All Spans) Member Length : 12' 1 1/4" System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 4/12 •Deflection criteria: LL (L/360) and TL (L/240). •A 15% increase in the moment capacity has been added to account for repetitive member usage. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Wind Factored Accessories 1 - Beveled Plate - DF 3.50"3.50"1.50"97 123 -123 220/-15 Blocking 2 - Hanger on 7 1/4" DF beam 1.50"Hanger¹1.50"95 121 -121 216/-15 See note ¹ •Dimensions for lateral bracing intervals are measured along the length of the member for sloped conditions. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger LRU26Z 1.94"N/A 4-10dx1.5 5-10d •Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Roof Live Wind Vertical Load Location (Side)Spacing (0.90)(1.25)(1.60)Comments 1 - Uniform (PSF)0 to 11' 5"16"12.0 16.0 -16.0 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED ROOF, RR-2 1 piece(s) 2 x 8 DF No.2 @ 16" OC Page 151 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)154 @ 8' 3 1/2"1406 (1.50")Passed (11%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)132 @ 7' 8 5/8"1631 Passed (8%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)312 @ 4' 3"1700 Passed (18%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.030 @ 4' 3"0.284 Passed (L/999+)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.053 @ 4' 3"0.426 Passed (L/999+)--1.0 D + 1.0 Lr (All Spans) Member Length : 8' 11 5/16" System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 4/12 •Deflection criteria: LL (L/360) and TL (L/240). •A 15% increase in the moment capacity has been added to account for repetitive member usage. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Wind Factored Accessories 1 - Beveled Plate - DF 3.50"3.50"1.50"72 91 -91 162/-11 Blocking 2 - Hanger on 7 1/4" DF beam 1.50"Hanger¹1.50"70 89 -89 159/-11 See note ¹ •Dimensions for lateral bracing intervals are measured along the length of the member for sloped conditions. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger LRU26Z 1.94"N/A 4-10dx1.5 5-10d •Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Roof Live Wind Vertical Load Location (Side)Spacing (0.90)(1.25)(1.60)Comments 1 - Uniform (PSF)0 to 8' 5"16"12.0 16.0 -16.0 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED ROOF, RR-3 1 piece(s) 2 x 8 DF No.2 @ 16" OC Page 152 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)158 @ 9' 6 1/2"1406 (1.50")Passed (11%)--1.0 D + 1.0 Lr (Alt Spans) Shear (lbs)136 @ 8' 11 5/8"1631 Passed (8%)1.25 1.0 D + 1.0 Lr (Alt Spans) Moment (Ft-lbs)328 @ 5' 4 13/16"1700 Passed (19%)1.25 1.0 D + 1.0 Lr (Alt Spans) Live Load Defl. (in)0.034 @ 5' 4 1/4"0.295 Passed (L/999+)--1.0 D + 1.0 Lr (Alt Spans) Total Load Defl. (in)0.060 @ 5' 4 5/16"0.442 Passed (L/999+)--1.0 D + 1.0 Lr (Alt Spans) Member Length : 10' 3 1/8" System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 4/12 •Deflection criteria: LL (L/360) and TL (L/240). •Overhang deflection criteria: LL (2L/360) and TL (2L/240). •A 15% increase in the moment capacity has been added to account for repetitive member usage. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Wind Factored Accessories 1 - Beveled Plate - DF 3.50"3.50"1.50"91 116 -116 207/-15 Blocking 2 - Hanger on 7 1/4" DF beam 1.50"Hanger¹1.50"71 91 -92 163/-12 See note ¹ •Dimensions for lateral bracing intervals are measured along the length of the member for sloped conditions. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger LRU26Z 1.94"N/A 4-10dx1.5 5-10d •Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Roof Live Wind Vertical Load Location (Side)Spacing (0.90)(1.25)(1.60)Comments 1 - Uniform (PSF)0 to 9' 8"16"12.0 16.0 -16.0 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED ROOF, RR-4 1 piece(s) 2 x 8 DF No.2 @ 16" OC Page 153 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)91 @ 1' 1 3/4"3459 (3.50")Passed (3%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)20 @ 1' 10 3/8"1631 Passed (1%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)-25 @ 1' 1 3/4"1662 Passed (2%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.000 @ 0 0.200 Passed (2L/999+)--1.0 D + 1.0 Lr (Alt Spans) Total Load Defl. (in)0.000 @ 0 0.200 Passed (2L/999+)--1.0 D + 1.0 Lr (Alt Spans) Member Length : 3' 2 13/16" System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 4/12 •Deflection criteria: LL (L/360) and TL (L/240). •Overhang deflection criteria: LL (0.2") and TL (0.2"). •Left cantilever length exceeds 1/3 member length or 1/2 back span length. Additional bracing should be considered. •A 15% increase in the moment capacity has been added to account for repetitive member usage. •A 2.3% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Wind Factored Accessories 1 - Beveled Plate - DF 3.50"3.50"1.50"40 51 -51 91/-6 Blocking 2 - Hanger on 7 1/4" DF beam 1.50"Hanger¹1.50"10 17 5/-21 27/-7 See note ¹ •Dimensions for lateral bracing intervals are measured along the length of the member for sloped conditions. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger LRU26Z 1.94"N/A 4-10dx1.5 5-10d •Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Roof Live Wind Vertical Load Location (Side)Spacing (0.90)(1.25)(1.60)Comments 1 - Uniform (PSF)0 to 3'16"12.0 16.0 -16.0 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED ROOF, RR-5 1 piece(s) 2 x 8 DF No.2 @ 16" OC Page 154 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)150 @ 8' 10 1/4"1406 (1.50")Passed (11%)--1.0 D + 1.0 L (All Spans) Shear (lbs)134 @ 8' 4 3/4"990 Passed (14%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)324 @ 4' 6 3/8"672 Passed (48%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.101 @ 4' 6 3/8"0.288 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.131 @ 4' 6 3/8"0.432 Passed (L/792)--1.0 D + 1.0 L (All Spans) Member Length : 8' 10 1/4" System : Ceiling Member Type : Attic Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •A 8.9% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor/Ceiling Live Factored Accessories 1 - Stud wall - DF 3.50"3.50"1.50"36 121 157 Blocking 2 - Hanger on 5 1/2" DF beam 1.50"Hanger¹1.50"36 119 154 See note ¹ Lateral Bracing Bracing Intervals Comments Top Edge (Lu)8' o/c Bottom Edge (Lu)End Bearing Points Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger LU26 1.50"N/A 6-10dx1.5 4-10dx1.5 •Refer to manufacturer notes and instructions for proper installation and use of all connectors. • Only vertical loads are available for Attic Joist member types. No tension loading will be considered in the design for these members. Dead Floor/Ceiling Live Vertical Load Location (Side)Spacing (0.90)(1.00)Comments 1 - Uniform (PSF)0 to 8' 11 3/4"16"6.0 20.0 CLG Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, CJ-1 1 piece(s) 2 x 6 DF No.2 @ 16" OC Page 155 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)170 @ 1 1/2"1406 (1.50")Passed (12%)--1.0 D + 1.0 L (All Spans) Shear (lbs)154 @ 7"990 Passed (16%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)417 @ 5' 3/8"672 Passed (62%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.167 @ 5' 3/8"0.327 Passed (L/704)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.217 @ 5' 3/8"0.491 Passed (L/542)--1.0 D + 1.0 L (All Spans) Member Length : 9' 9 3/4" System : Ceiling Member Type : Attic Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •A 8.9% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor/Ceiling Live Factored Accessories 1 - Hanger on 5 1/2" DF beam 1.50"Hanger¹1.50"40 134 174 See note ¹ 2 - Hanger on 5 1/2" DF beam 1.50"Hanger¹1.50"40 134 174 See note ¹ Lateral Bracing Bracing Intervals Comments Top Edge (Lu)8' o/c Bottom Edge (Lu)End Bearing Points Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1 - Face Mount Hanger LU26 1.50"N/A 6-10dx1.5 4-10dx1.5 2 - Face Mount Hanger LU26 1.50"N/A 6-10dx1.5 4-10dx1.5 •Refer to manufacturer notes and instructions for proper installation and use of all connectors. • Only vertical loads are available for Attic Joist member types. No tension loading will be considered in the design for these members. Dead Floor/Ceiling Live Vertical Load Location (Side)Spacing (0.90)(1.00)Comments 1 - Uniform (PSF)0 to 10' 3/4"16"6.0 20.0 CLG Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, CJ-2 1 piece(s) 2 x 6 DF No.2 @ 16" OC Page 156 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)75 @ 1 1/2"1406 (1.50")Passed (5%)--1.0 D + 1.0 L (All Spans) Shear (lbs)59 @ 7"990 Passed (6%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)81 @ 2' 3 3/8"713 Passed (11%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.006 @ 2' 3 3/8"0.144 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.008 @ 2' 3 3/8"0.216 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Member Length : 4' 3 3/4" System : Ceiling Member Type : Attic Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •A 3.2% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor/Ceiling Live Factored Accessories 1 - Hanger on 5 1/2" DF beam 1.50"Hanger¹1.50"18 61 79 See note ¹ 2 - Hanger on 5 1/2" DF beam 1.50"Hanger¹1.50"18 61 79 See note ¹ Lateral Bracing Bracing Intervals Comments Top Edge (Lu)4' 3 3/4" o/c Bottom Edge (Lu)End Bearing Points Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1 - Face Mount Hanger LU26 1.50"N/A 6-10dx1.5 4-10dx1.5 2 - Face Mount Hanger LU26 1.50"N/A 6-10dx1.5 4-10dx1.5 •Refer to manufacturer notes and instructions for proper installation and use of all connectors. • Only vertical loads are available for Attic Joist member types. No tension loading will be considered in the design for these members. Dead Floor/Ceiling Live Vertical Load Location (Side)Spacing (0.90)(1.00)Comments 1 - Uniform (PSF)0 to 4' 6 3/4"16"6.0 20.0 CLG Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, CJ-3 1 piece(s) 2 x 6 DF No.2 @ 16" OC Page 157 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)170 @ 2 1/2"3281 (3.50")Passed (5%)--1.0 D + 1.0 L (All Spans) Shear (lbs)144 @ 9"990 Passed (15%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)381 @ 4' 10 3/4"672 Passed (57%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.139 @ 4' 10 3/4"0.313 Passed (L/808)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.181 @ 4' 10 3/4"0.469 Passed (L/621)--1.0 D + 1.0 L (All Spans) Member Length : 9' 9 1/2" System : Ceiling Member Type : Attic Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •A 8.9% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor/Ceiling Live Factored Accessories 1 - Stud wall - DF 3.50"3.50"1.50"39 131 170 Blocking 2 - Stud wall - DF 3.50"3.50"1.50"39 131 170 Blocking Lateral Bracing Bracing Intervals Comments Top Edge (Lu)8' o/c Bottom Edge (Lu)End Bearing Points • Only vertical loads are available for Attic Joist member types. No tension loading will be considered in the design for these members. Dead Floor/Ceiling Live Vertical Load Location (Side)Spacing (0.90)(1.00)Comments 1 - Uniform (PSF)0 to 9' 9 1/2"16"6.0 20.0 CLG Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, CJ-4 1 piece(s) 2 x 6 DF No.2 @ 16" OC Page 158 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)193 @ 11' 4 1/4"1406 (1.50")Passed (14%)--1.0 D + 1.0 L (All Spans) Shear (lbs)177 @ 10' 10 3/4"990 Passed (18%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)538 @ 5' 9 3/8"672 Passed (80%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.278 @ 5' 9 3/8"0.372 Passed (L/481)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.362 @ 5' 9 3/8"0.557 Passed (L/370)--1.0 D + 1.0 L (All Spans) Member Length : 11' 4 1/4" System : Ceiling Member Type : Attic Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •A 8.9% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor/Ceiling Live Factored Accessories 1 - Stud wall - DF 3.50"3.50"1.50"46 154 200 Blocking 2 - Hanger on 5 1/2" DF beam 1.50"Hanger¹1.50"46 152 198 See note ¹ Lateral Bracing Bracing Intervals Comments Top Edge (Lu)8' o/c Bottom Edge (Lu)End Bearing Points Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger LU26 1.50"N/A 6-10dx1.5 4-10dx1.5 •Refer to manufacturer notes and instructions for proper installation and use of all connectors. • Only vertical loads are available for Attic Joist member types. No tension loading will be considered in the design for these members. Dead Floor/Ceiling Live Vertical Load Location (Side)Spacing (0.90)(1.00)Comments 1 - Uniform (PSF)0 to 11' 5 3/4"16"6.0 20.0 CLG Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, CJ-5 1 piece(s) 2 x 6 DF No.2 @ 16" OC Page 159 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)198 @ 11' 5 7/8"1641 (1.75")Passed (12%)--1.0 D + 1.0 L (All Spans) Shear (lbs)177 @ 9"990 Passed (18%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)551 @ 5' 10 3/16"672 Passed (82%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.292 @ 5' 10 3/16"0.376 Passed (L/464)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.380 @ 5' 10 3/16"0.564 Passed (L/357)--1.0 D + 1.0 L (All Spans) Member Length : 11' 6 5/8" System : Ceiling Member Type : Attic Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •A 8.9% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor/Ceiling Live Factored Accessories 1 - Stud wall - DF 3.50"3.50"1.50"47 156 203 Blocking 2 - Stud wall - DF 1.75"1.75"1.50"46 152 198 Blocking Lateral Bracing Bracing Intervals Comments Top Edge (Lu)8' o/c Bottom Edge (Lu)End Bearing Points • Only vertical loads are available for Attic Joist member types. No tension loading will be considered in the design for these members. Dead Floor/Ceiling Live Vertical Load Location (Side)Spacing (0.90)(1.00)Comments 1 - Uniform (PSF)0 to 11' 6 5/8"16"6.0 20.0 CLG Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, CJ-6 1 piece(s) 2 x 6 DF No.2 @ 16" OC Page 160 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)137 @ 1 1/2"1406 (1.50")Passed (10%)--1.0 D + 1.0 L (All Spans) Shear (lbs)121 @ 7"990 Passed (12%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)272 @ 4' 1"673 Passed (40%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.071 @ 4' 1"0.264 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.092 @ 4' 1"0.396 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Member Length : 7' 11" System : Ceiling Member Type : Attic Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •Top custom unbraced length is too long and has been reset to the member length of 7' 11" •A 8.7% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor/Ceiling Live Factored Accessories 1 - Hanger on 5 1/2" DF beam 1.50"Hanger¹1.50"33 109 142 See note ¹ 2 - Hanger on 5 1/2" DF beam 1.50"Hanger¹1.50"33 109 142 See note ¹ Lateral Bracing Bracing Intervals Comments Top Edge (Lu)7' 11" o/c Bottom Edge (Lu)End Bearing Points Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1 - Face Mount Hanger LU26 1.50"N/A 6-10dx1.5 4-10dx1.5 2 - Face Mount Hanger LU26 1.50"N/A 6-10dx1.5 4-10dx1.5 •Refer to manufacturer notes and instructions for proper installation and use of all connectors. • Only vertical loads are available for Attic Joist member types. No tension loading will be considered in the design for these members. Dead Floor/Ceiling Live Vertical Load Location (Side)Spacing (0.90)(1.00)Comments 1 - Uniform (PSF)0 to 8' 2"16"6.0 20.0 CLG Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, CJ-7 1 piece(s) 2 x 6 DF No.2 @ 16" OC Page 161 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)99 @ 3/4"1641 (1.75")Passed (6%)--1.0 D + 1.0 L (All Spans) Shear (lbs)79 @ 7 1/4"990 Passed (8%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)137 @ 2' 10 7/16"703 Passed (19%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.018 @ 2' 10 7/16"0.187 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.023 @ 2' 10 7/16"0.281 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Member Length : 5' 10 5/8" System : Ceiling Member Type : Attic Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •Top custom unbraced length is too long and has been reset to the member length of 5' 7 3/8" •A 4.7% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor/Ceiling Live Factored Accessories 1 - Stud wall - DF 1.75"1.75"1.50"23 77 99 Blocking 2 - Stud wall - DF 3.50"3.50"1.50"24 80 105 Blocking Lateral Bracing Bracing Intervals Comments Top Edge (Lu)5' 7" o/c Bottom Edge (Lu)End Bearing Points • Only vertical loads are available for Attic Joist member types. No tension loading will be considered in the design for these members. Dead Floor/Ceiling Live Vertical Load Location (Side)Spacing (0.90)(1.00)Comments 1 - Uniform (PSF)0 to 5' 10 5/8"16"6.0 20.0 CLG Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, CJ-8 1 piece(s) 2 x 6 DF No.2 @ 16" OC Page 162 of 213 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)159 @ 9' 2 7/8"1641 (1.75")Passed (10%)--1.0 D + 1.0 L (All Spans) Shear (lbs)138 @ 9"990 Passed (14%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)353 @ 4' 8 11/16"672 Passed (53%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.120 @ 4' 8 11/16"0.301 Passed (L/903)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.156 @ 4' 8 11/16"0.452 Passed (L/695)--1.0 D + 1.0 L (All Spans) Member Length : 9' 3 5/8" System : Ceiling Member Type : Attic Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor/Ceiling Live Factored Accessories 1 - Stud wall - DF 3.50"3.50"1.50"38 126 164 Blocking 2 - Stud wall - DF 1.75"1.75"1.50"37 122 159 Blocking Lateral Bracing Bracing Intervals Comments Top Edge (Lu)8' o/c Bottom Edge (Lu)End Bearing Points • Only vertical loads are available for Attic Joist member types. No tension loading will be considered in the design for these members. Dead Floor/Ceiling Live Vertical Load Location (Side)Spacing (0.90)(1.00)Comments 1 - Uniform (PSF)0 to 9' 3 5/8"16"6.0 20.0 CLG Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED CLG, CJ-9 1 piece(s) 2 x 6 DF No.2 @ 16" OC Page 163 of 213 S Van Ness Ave Appendix H : Stud Wall Design Page 164 of 213 Wall Height: 8'Member Height: 7' 7 1/2"O. C. Spacing: 16.00" Design Results Actual Allowed Result LDF Load: Combination Slenderness 32 50 Passed (64%)---- Compression (lbs)350 2309 Passed (15%)1.25 1.0 D + 0.75 L + 0.75 Lr Plate Bearing (lbs)350 4102 Passed (9%)--1.0 D + 0.75 L + 0.75 Lr Lateral Reaction (lbs)52 ----1.60 1.0 D + 0.6 W Lateral Shear (lbs)48 1008 Passed (5%)1.60 1.0 D + 0.6 W Lateral Moment (ft-lbs)98 @ mid-span 607 Passed (16%)1.60 1.0 D + 0.6 W Total Deflection (in)0.08 @ mid-span 0.25 Passed (L/1089)--1.0 D + 0.6 W Bending/Compression 0.17 1 Passed (17%)1.60 1.0 D + 0.6 W •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. •A bearing area factor of 1.25 has been applied to base plate bearing capacity. •A 15% increase in the moment capacity has been added to account for repetitive member usage. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 4' System : Wall Member Type : Stud Building Code : IBC 2021 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 8d (0.113" x 2 1/2") (Toe)2 N/A Base Nails 8d (0.113" x 2 1/2") (Toe)2 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Dead Floor Live Roof Live Wind Vertical Loads Spacing (0.90)(1.00)(1.25)(1.60)Comments 1 - Point (lb)N/A 114 -145 -145 Linked from: RR-1, Support 1 2 - Point (lb)N/A 36 121 --Linked from: CJ-1, Support 1 • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8' 6"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Wind Zone (4), GCpi (+/- 0.18), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Spacing (1.60)Comments 1 - Uniform (PSF)Full Length 16.00"16.9 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, EXT.STUD 1 piece(s) 2 x 4 DF No.2 @ 16" OC Page 165 of 213 Wall Height: 8'Member Height: 7' 7 1/2"O. C. Spacing: 16.00" Design Results Actual Allowed Result LDF Load: Combination Slenderness 32 50 Passed (64%)---- Compression (lbs)370 2269 Passed (16%)1.00 1.0 D + 1.0 L Plate Bearing (lbs)370 4102 Passed (9%)--1.0 D + 1.0 L Lateral Reaction (lbs)0 ------N/A Lateral Shear (lbs)0 N/A Passed (N/A)--N/A Lateral Moment (ft-lbs)0 @ mid-span N/A Passed (N/A)--N/A Total Deflection (in)0.00 @ mid-span N/A Passed (N/A)--N/A Bending/Compression N/A 1 Passed (N/A)--N/A •Lateral deflection criteria: Wind (L/360) •Input axial load eccentricity for the design is zero •Applicable calculations are based on NDS. •A bearing area factor of 1.25 has been applied to base plate bearing capacity. •A 15% increase in the moment capacity has been added to account for repetitive member usage. Supports Type Material Top Dbl 2X Douglas Fir-Larch Base 2X Douglas Fir-Larch Max Unbraced Length Comments 4' System : Wall Member Type : Stud Building Code : IBC 2021 Design Methodology : ASD Dead Floor Live Vertical Loads Spacing (0.90)(1.00)Comments 1 - Point (lb)N/A 39 131 Linked from: CJ-4, Support 2 2 - Point (lb)N/A 46 154 Linked from: CJ-5, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED CLG, INT.STUD 1 piece(s) 2 x 4 DF No.2 @ 16" OC Page 166 of 213 S Van Ness Ave Appendix I : Foundation Design Page 167 of 213 Sazan 606 1 LINE 2 R1 Eng. 2024-12-15 DR.Jalalpour 2024-12-15 DR.Rezaeian 2024-12-15 FOOTING ANALYSIS In accordance with ACI318-19 Overall design status PASS Overall design utilization; 0.717 Description Unit Applied Resisting Utilization Result Pad footing details Length of footing L=11 ft Width of footing b=12 in Footing area A=0.92 ft2 Depth of footing H=24 in Density of concrete mass=145 lb/ft3 load case : Weight , D , Lr Point loads Distributed Loads 0.47 0.47 0 11 Weight 0.2 0.2 0 11 D 0.4 0.4 0 11 Lr Footing analysis for soil and stability Load combinations per ASCE 7-16 Page 168 of 213 ASD01: +D+Weight ASD02: +D+Weight+L ASD03: +D+Weight+Lr ASD04: +D+Weight+S ASD05: +D+Weight+0.75L+0.75Lr ASD06: +D+Weight+0.75L+0.75S ASD07: +D+Weight+0.6W ASD08: +D+Weight+0.75L+0.45W+0.75Lr ASD09: +D+Weight+0.75L+0.45W+0.75S ASD10: +D+Weight+0.14D+0.14Weight+0.7Eh ASD11: +D+Weight+0.11D+0.11Weight+0.525Eh+0.75L+0.75S ASD12: +0.6D+0.6Weight-0.14D-0.14Weight+0.7Eh ASD13: +D+Weight+0.14D+0.14Weight-0.7Eh ASD14: +D+Weight+0.11D+0.11Weight-0.525Eh+0.75L+0.75S ASD15: +0.6D+0.6Weight-0.14D-0.14Weight-0.7Eh Load Combinations q max q min q allowed Check Bearing Stress L/6 e L' Page 169 of 213 ASD03 FOOTING DESIGN In accordance with ACI318-19 Material details Compressive strength of concrete f'c = 4500 psi Concrete type Normal Analysis and design of concrete footing Load combinations per ASCE 7-16 LRFD01: +1.4D+1.4Weight LRFD02: +1.2D+1.2Weight+1.6L+0.5Lr LRFD03: +1.2D+1.2Weight+1.6Lr+L LRFD04: +1.2D+1.2Weight+1.6Lr+0.5W LRFD05: +1.2D+1.2Weight+1.6Lr-0.5W LRFD06: +1.2D+1.2Weight+1.6S+L LRFD07: +1.2D+1.2Weight+1.6S+0.5W LRFD08: +1.2D+1.2Weight+1.6S-0.5W LRFD09: +1.2D+1.2Weight+W+L+0.5Lr LRFD10: +1.2D+1.2Weight-W+L+0.5Lr LRFD11: +1.2D+1.2Weight+W+L+0.5S LRFD12: +1.2D+1.2Weight-W+L+0.5S LRFD13: +1.2D+1.2Weight+Eh+L+0.2S+0.21D+0.21Weight LRFD14: +1.2D+1.2Weight-Eh+L+0.2S+0.21D+0.21Weight LRFD15: +0.9D+0.9Weight+Eh-0.21D-0.21Weight LRFD16: +0.9D+0.9Weight-Eh-0.21D-0.21Weight LRFD17: +0.9D+0.9Weight+W LRFD18: +0.9D+0.9Weight Page 170 of 213 Combination 2 results: Envelop φMn_Po φMn_Ne φVn 4.65 0.0161 0 0.04 0 16.23 16.23 14.1 7 Ok Ok 0 0 8.35 0.001557 5 - 0.0065 5 0.06 0 16.23 16.23 14.1 7 Ok Ok 0 0 10.9 5 0 -0.07 0 0 16.23 16.23 14.1 7 Ok Ok 0 0 10.9 5 0 -0.07 0 0 16.23 16.23 14.1 7 Ok Ok 0 0 H =24 h =22 bf =12 bw =12 tf =5 Yt = (h✕bw✕h/2+Max(0,(bf-bw)✕tf✕tf/2))/(h✕bw+Max(0,(bf-bw)✕tf))= 11 in Yb = h-Yt11 in I = bw✕h✕h✕h/12+h✕bw✕(h/2-Yt)✕(h/2-Yt)+Max(0,(bf-bw))✕tf✕tf✕tf/12+Max(0,(bf-bw))✕tf✕(tf/2- Yt)✕(tf/2-Yt)= 10648 in4 St = I/Yt= 968 in3 Sb = I/Yb= 968 in3 fr = 5√fc= 335.41 psi φMn_Pos=0.6✕(Min(St✕0.85✕f'c, Sb✕fr)/12000) φMn_Neg=0.6✕(Min(St✕fr,Sb✕0.85✕f'c)/12000) Page 171 of 213 φVn=0.6 * (4/3*√fc*bw*h/1000) Page 172 of 213 Sazan 606 1 LINE 3 R1 Eng. 2024-12-17 DR.Jalalpour 2024-12-17 DR.Rezaeian 2024-12-17 FOOTING ANALYSIS In accordance with ACI318-19 Overall design status PASS Overall design utilization; 0.799 Description Unit Applied Resisting Utilization Result Pad footing details Length of footing L=13.9 ft Width of footing b=12 in Footing area A=1.16 ft2 Depth of footing H=24 in Density of concrete mass=145 lb/ft3 load case : Eh , W , D , Lr , Weight , L Point loads -2.1 0.5 Eh -2.8 0.5 W 2.1 13.6 Eh 2.5 13.6 W 0.5 13.6 D 0.2 7 Lr -0.2 7 W 0.2 10 Lr -0.2 10 W Page 173 of 213 Eh W D Page 174 of 213 Lr Distributed Loads 0.47 0.47 0 13.9 Weight 0.27 0.27 0 13.9 D 0.1 0.1 0 13.9 Lr 0.11 0.11 0 13.9 L Footing analysis for soil and stability Load combinations per ASCE 7-16 ASD01: +D+Weight ASD02: +D+Weight+L ASD03: +D+Weight+Lr ASD04: +D+Weight+S ASD05: +D+Weight+0.75L+0.75Lr ASD06: +D+Weight+0.75L+0.75S ASD07: +D+Weight+0.6W ASD08: +D+Weight+0.75L+0.45W+0.75Lr ASD09: +D+Weight+0.75L+0.45W+0.75S ASD10: +D+Weight+0.14D+0.14Weight+0.7Eh ASD11: +D+Weight+0.11D+0.11Weight+0.525Eh+0.75L+0.75S ASD12: +0.6D+0.6Weight-0.14D-0.14Weight+0.7Eh Page 175 of 213 ASD13: +D+Weight+0.14D+0.14Weight-0.7Eh ASD14: +D+Weight+0.11D+0.11Weight-0.525Eh+0.75L+0.75S ASD15: +0.6D+0.6Weight-0.14D-0.14Weight-0.7Eh Load Combinations q max q min q allowed Check Bearing Stress L/6 e L' ASD10 FOOTING DESIGN In accordance with ACI318-19 Material details Compressive strength of concrete f'c = 4500 psi Concrete type Normal Analysis and design of concrete footing Load combinations per ASCE 7-16 LRFD01: +1.4D+1.4Weight LRFD02: +1.2D+1.2Weight+1.6L+0.5Lr Page 176 of 213 LRFD03: +1.2D+1.2Weight+1.6Lr+L LRFD04: +1.2D+1.2Weight+1.6Lr+0.5W LRFD05: +1.2D+1.2Weight+1.6Lr-0.5W LRFD06: +1.2D+1.2Weight+1.6S+L LRFD07: +1.2D+1.2Weight+1.6S+0.5W LRFD08: +1.2D+1.2Weight+1.6S-0.5W LRFD09: +1.2D+1.2Weight+W+L+0.5Lr LRFD10: +1.2D+1.2Weight-W+L+0.5Lr LRFD11: +1.2D+1.2Weight+W+L+0.5S LRFD12: +1.2D+1.2Weight-W+L+0.5S LRFD13: +1.2D+1.2Weight+Eh+L+0.2S+0.21D+0.21Weight LRFD14: +1.2D+1.2Weight-Eh+L+0.2S+0.21D+0.21Weight LRFD15: +0.9D+0.9Weight+Eh-0.21D-0.21Weight LRFD16: +0.9D+0.9Weight-Eh-0.21D-0.21Weight LRFD17: +0.9D+0.9Weight+W LRFD18: +0.9D+0.9Weight Combination 2 results: Envelop φMn_Po φMn_Ne φVn 13.5 5 2.6662 - 1.8333 5 0.05 -0.19 16.23 16.23 14.1 7 Ok Ok 0.19 0.01 4.25 0.46665 - 0.7050 5 4.49 -2.92 16.23 16.23 14.1 7 Ok Ok 0.05 0.28 0.5 2.46665 - 2.3050 5 0.13 -0.13 16.23 16.23 14.1 7 Ok Ok 0.17 0.01 10.5 5 0.22883 5 - 0.5233 5 2.47 -3.89 16.23 16.23 14.1 7 Ok Ok 0.04 0.24 Page 177 of 213 H =24 h =22 bf =12 bw =12 tf =5 Yt = (h✕bw✕h/2+Max(0,(bf-bw)✕tf✕tf/2))/(h✕bw+Max(0,(bf-bw)✕tf))= 11 in Yb = h-Yt11 in I = bw✕h✕h✕h/12+h✕bw✕(h/2-Yt)✕(h/2-Yt)+Max(0,(bf-bw))✕tf✕tf✕tf/12+Max(0,(bf-bw))✕tf✕(tf/2- Yt)✕(tf/2-Yt)= 10648 in4 St = I/Yt= 968 in3 Sb = I/Yb= 968 in3 fr = 5√fc= 335.41 psi φMn_Pos=0.6✕(Min(St✕0.85✕f'c, Sb✕fr)/12000) φMn_Neg=0.6✕(Min(St✕fr,Sb✕0.85✕f'c)/12000) φVn=0.6 * (4/3*√fc*bw*h/1000) Page 178 of 213 Sazan 606 1 LINE A-1 R1 Eng. 2024-12-17 DR.Jalalpour 2024-12-17 DR.Rezaeian 2024-12-17 FOOTING ANALYSIS In accordance with ACI318-19 Overall design status PASS Overall design utilization; 0.665 Description Unit Applied Resisting Utilization Result Pad footing details Length of footing L=9.4 ft Width of footing b=12 in Footing area A=0.78 ft2 Depth of footing H=24 in Density of concrete mass=145 lb/ft3 load case : Lr , W , Weight , D , L Point loads 0.07 1.4 Lr 0.07 7.9 Lr 0.5 9.1 Lr -0.07 1.4 W -0.07 7.9 W -0.5 9.1 W Page 179 of 213 Lr W Distributed Loads 0.47 0.47 0 9.4 Weight 0.29 0.29 0 9.4 D 0.02 0.02 0 9.4 Lr 0.02 0.02 0 9.4 L Footing analysis for soil and stability Load combinations per ASCE 7-16 ASD01: +D+Weight ASD02: +D+Weight+L ASD03: +D+Weight+Lr Page 180 of 213 ASD04: +D+Weight+S ASD05: +D+Weight+0.75L+0.75Lr ASD06: +D+Weight+0.75L+0.75S ASD07: +D+Weight+0.6W ASD08: +D+Weight+0.75L+0.45W+0.75Lr ASD09: +D+Weight+0.75L+0.45W+0.75S ASD10: +D+Weight+0.14D+0.14Weight+0.7Eh ASD11: +D+Weight+0.11D+0.11Weight+0.525Eh+0.75L+0.75S ASD12: +0.6D+0.6Weight-0.14D-0.14Weight+0.7Eh ASD13: +D+Weight+0.14D+0.14Weight-0.7Eh ASD14: +D+Weight+0.11D+0.11Weight-0.525Eh+0.75L+0.75S ASD15: +0.6D+0.6Weight-0.14D-0.14Weight-0.7Eh Load Combinations q max q min q allowed Check Bearing Stress L/6 e L' ASD03 Page 181 of 213 FOOTING DESIGN In accordance with ACI318-19 Material details Compressive strength of concrete f'c = 4500 psi Concrete type Normal Analysis and design of concrete footing Load combinations per ASCE 7-16 LRFD01: +1.4D+1.4Weight LRFD02: +1.2D+1.2Weight+1.6L+0.5Lr LRFD03: +1.2D+1.2Weight+1.6Lr+L LRFD04: +1.2D+1.2Weight+1.6Lr+0.5W LRFD05: +1.2D+1.2Weight+1.6Lr-0.5W LRFD06: +1.2D+1.2Weight+1.6S+L LRFD07: +1.2D+1.2Weight+1.6S+0.5W LRFD08: +1.2D+1.2Weight+1.6S-0.5W LRFD09: +1.2D+1.2Weight+W+L+0.5Lr LRFD10: +1.2D+1.2Weight-W+L+0.5Lr LRFD11: +1.2D+1.2Weight+W+L+0.5S LRFD12: +1.2D+1.2Weight-W+L+0.5S LRFD13: +1.2D+1.2Weight+Eh+L+0.2S+0.21D+0.21Weight LRFD14: +1.2D+1.2Weight-Eh+L+0.2S+0.21D+0.21Weight LRFD15: +0.9D+0.9Weight+Eh-0.21D-0.21Weight LRFD16: +0.9D+0.9Weight-Eh-0.21D-0.21Weight LRFD17: +0.9D+0.9Weight+W LRFD18: +0.9D+0.9Weight Combination 2 results: Envelop φMn_Po φMn_Ne φVn Page 182 of 213 9.0 5 0.893 6 - 0.426 7 0.01 -0.03 16.23 16.23 14.1 7 Ok Ok 0.06 0 6.0 5 0.043 6 - 0.022 9 0.64 -1.33 16.23 16.23 14.1 7 Ok Ok 0 0.08 9.0 5 0.893 6 - 0.426 7 0.01 -0.03 16.23 16.23 14.1 7 Ok Ok 0.06 0 6 0.033 6 - 0.016 7 0.64 -1.34 16.23 16.23 14.1 7 Ok Ok 0 0.08 H =24 h =22 bf =12 bw =12 tf =5 Yt = (h✕bw✕h/2+Max(0,(bf-bw)✕tf✕tf/2))/(h✕bw+Max(0,(bf-bw)✕tf))= 11 in Yb = h-Yt11 in I = bw✕h✕h✕h/12+h✕bw✕(h/2-Yt)✕(h/2-Yt)+Max(0,(bf-bw))✕tf✕tf✕tf/12+Max(0,(bf-bw))✕tf✕(tf/2- Yt)✕(tf/2-Yt)= 10648 in4 St = I/Yt= 968 in3 Sb = I/Yb= 968 in3 fr = 5√fc= 335.41 psi φMn_Pos=0.6✕(Min(St✕0.85✕f'c, Sb✕fr)/12000) φMn_Neg=0.6✕(Min(St✕fr,Sb✕0.85✕f'c)/12000) φVn=0.6 * (4/3*√fc*bw*h/1000) Page 183 of 213 Sazan 606 1 LINE A-2 R1 Eng. 2024-12-17 DR.Jalalpour 2024-12-17 DR.Rezaeian 2024-12-17 FOOTING ANALYSIS In accordance with ACI318-19 Overall design status PASS Overall design utilization; 0.662 Description Unit Applied Resisting Utilization Result Pad footing details Length of footing L=9.4 ft Width of footing b=12 in Footing area A=0.78 ft2 Depth of footing H=24 in Density of concrete mass=145 lb/ft3 load case : Eh , W , Lr , Weight , D , L Point loads -2.1 6.8 Eh -2.2 6.8 W 2.1 9 Eh 2.1 9 W 0.5 0.3 Lr 0.06 0.9 Lr 0.06 6.5 Lr -0.5 0.3 W -0.06 0.9 W Page 184 of 213 -0.06 6.5 W Eh W Lr Page 185 of 213 Distributed Loads 0.47 0.47 0 9.4 Weight 0.28 0.28 0 9.4 D 0.02 0.02 0 9.4 Lr 0.02 0.02 0 9.4 L Footing analysis for soil and stability Load combinations per ASCE 7-16 ASD01: +D+Weight ASD02: +D+Weight+L ASD03: +D+Weight+Lr ASD04: +D+Weight+S ASD05: +D+Weight+0.75L+0.75Lr ASD06: +D+Weight+0.75L+0.75S ASD07: +D+Weight+0.6W ASD08: +D+Weight+0.75L+0.45W+0.75Lr ASD09: +D+Weight+0.75L+0.45W+0.75S ASD10: +D+Weight+0.14D+0.14Weight+0.7Eh ASD11: +D+Weight+0.11D+0.11Weight+0.525Eh+0.75L+0.75S ASD12: +0.6D+0.6Weight-0.14D-0.14Weight+0.7Eh ASD13: +D+Weight+0.14D+0.14Weight-0.7Eh ASD14: +D+Weight+0.11D+0.11Weight-0.525Eh+0.75L+0.75S ASD15: +0.6D+0.6Weight-0.14D-0.14Weight-0.7Eh Load Combinations q max q min q allowed Check Bearing Stress L/6 e L' Page 186 of 213 ASD08 882.49 707.51 1995 OK 1.57 0.17 0 ASD09 936.18 524.88 1995 OK 1.57 0.44 0 ASD10 1074.6 635.4 1995 OK 1.57 0.4 0 ASD11 1012.2 682.8 1995 OK 1.57 0.3 0 ASD12 564.6 125.4 1995 OK 1.57 1 0 ASD13 1074.6 635.4 1995 OK 1.57 -0.4 0 ASD14 1012.2 682.8 1995 OK 1.57 -0.3 0 ASD15 564.6 125.4 1995 OK 1.57 -1 0 ASD03 FOOTING DESIGN In accordance with ACI318-19 Material details Compressive strength of concrete f'c = 4500 psi Concrete type Normal Analysis and design of concrete footing Load combinations per ASCE 7-16 LRFD01: +1.4D+1.4Weight LRFD02: +1.2D+1.2Weight+1.6L+0.5Lr LRFD03: +1.2D+1.2Weight+1.6Lr+L LRFD04: +1.2D+1.2Weight+1.6Lr+0.5W LRFD05: +1.2D+1.2Weight+1.6Lr-0.5W LRFD06: +1.2D+1.2Weight+1.6S+L LRFD07: +1.2D+1.2Weight+1.6S+0.5W LRFD08: +1.2D+1.2Weight+1.6S-0.5W LRFD09: +1.2D+1.2Weight+W+L+0.5Lr LRFD10: +1.2D+1.2Weight-W+L+0.5Lr LRFD11: +1.2D+1.2Weight+W+L+0.5S LRFD12: +1.2D+1.2Weight-W+L+0.5S Page 187 of 213 LRFD13: +1.2D+1.2Weight+Eh+L+0.2S+0.21D+0.21Weight LRFD14: +1.2D+1.2Weight-Eh+L+0.2S+0.21D+0.21Weight LRFD15: +0.9D+0.9Weight+Eh-0.21D-0.21Weight LRFD16: +0.9D+0.9Weight-Eh-0.21D-0.21Weight LRFD17: +0.9D+0.9Weight+W LRFD18: +0.9D+0.9Weight Combination 2 results: Envelop φMn_Po φMn_Ne φVn 8.9 5 1.966937 5 - 1.967062 5 0.07 -0.07 16.23 16.23 14.1 7 Ok Ok 0.14 0 6.8 1.512937 5 - 1.513062 5 3.76 -3.76 16.23 16.23 14.1 7 Ok Ok 0.11 0.23 8.9 5 1.966937 5 - 1.967062 5 0.07 -0.07 16.23 16.23 14.1 7 Ok Ok 0.14 0 6.8 1.512937 5 - 1.513062 5 3.76 -3.76 16.23 16.23 14.1 7 Ok Ok 0.11 0.23 H =24 h =22 bf =12 bw =12 tf =5 Yt = (h✕bw✕h/2+Max(0,(bf-bw)✕tf✕tf/2))/(h✕bw+Max(0,(bf-bw)✕tf))= 11 in Page 188 of 213 Yb = h-Yt11 in I = bw✕h✕h✕h/12+h✕bw✕(h/2-Yt)✕(h/2-Yt)+Max(0,(bf-bw))✕tf✕tf✕tf/12+Max(0,(bf-bw))✕tf✕(tf/2- Yt)✕(tf/2-Yt)= 10648 in4 St = I/Yt= 968 in3 Sb = I/Yb= 968 in3 fr = 5√fc= 335.41 psi φMn_Pos=0.6✕(Min(St✕0.85✕f'c, Sb✕fr)/12000) φMn_Neg=0.6✕(Min(St✕fr,Sb✕0.85✕f'c)/12000) φVn=0.6 * (4/3*√fc*bw*h/1000) Page 189 of 213 Sazan 606 1 LINE B R1 Eng. 2024-12-17 DR.Jalalpour 2024-12-17 DR.Rezaeian 2024-12-17 FOOTING ANALYSIS In accordance with ACI318-19 Overall design status PASS Overall design utilization; 0.643 Description Unit Applied Resisting Utilization Result Pad footing details Length of footing L=8.2 ft Width of footing b=16 in Footing area A=0.91 ft2 Depth of footing H=24 in Density of concrete mass=145 lb/ft3 load case : Eh , W , Lr , Weight , D , L Point loads 1.8 7.5 Eh 1.9 7.5 W 0.1 2.3 Lr 0.1 4.3 Lr -0.1 2.3 W -0.1 4.3 W -1.8 0.5 Eh -1.9 0.5 W Page 190 of 213 Eh W Lr Distributed Loads Page 191 of 213 W1 (Kip/ft) W2 (Kip/ft) a (ft) b (ft) loadCase 0.57 0.57 0 8.2 Weight 0.24 0.24 0 8.2 D 0.08 0.08 0 8.2 Lr 0.07 0.07 0 8.2 L Footing analysis for soil and stability Load combinations per ASCE 7-16 ASD01: +D+Weight ASD02: +D+Weight+L ASD03: +D+Weight+Lr ASD04: +D+Weight+S ASD05: +D+Weight+0.75L+0.75Lr ASD06: +D+Weight+0.75L+0.75S ASD07: +D+Weight+0.6W ASD08: +D+Weight+0.75L+0.45W+0.75Lr ASD09: +D+Weight+0.75L+0.45W+0.75S ASD10: +D+Weight+0.14D+0.14Weight+0.7Eh ASD11: +D+Weight+0.11D+0.11Weight+0.525Eh+0.75L+0.75S ASD12: +0.6D+0.6Weight-0.14D-0.14Weight+0.7Eh ASD13: +D+Weight+0.14D+0.14Weight-0.7Eh ASD14: +D+Weight+0.11D+0.11Weight-0.525Eh+0.75L+0.75S ASD15: +0.6D+0.6Weight-0.14D-0.14Weight-0.7Eh Load Combinations q max q min q allowed Check Bearing Stress L/6 e L' Page 192 of 213 ASD09 1044 233.28 1995 OK 1.37 0.87 0 ASD10 1282.82 102.28 1995 OK 1.37 1.16 0 ASD11 1156.41 270.99 1995 OK 1.37 0.85 0 ASD12 1259.17 0 1995 OK 1.37 2.89 4.56 ASD13 1282.82 102.28 1995 OK 1.37 -1.16 0 ASD14 1156.41 270.99 1995 OK 1.37 -0.85 0 ASD15 1259.17 0 1995 OK 1.37 -2.89 3.64 ASD10 FOOTING DESIGN In accordance with ACI318-19 Material details Compressive strength of concrete f'c = 4500 psi Concrete type Normal Analysis and design of concrete footing Load combinations per ASCE 7-16 LRFD01: +1.4D+1.4Weight LRFD02: +1.2D+1.2Weight+1.6L+0.5Lr LRFD03: +1.2D+1.2Weight+1.6Lr+L LRFD04: +1.2D+1.2Weight+1.6Lr+0.5W LRFD05: +1.2D+1.2Weight+1.6Lr-0.5W LRFD06: +1.2D+1.2Weight+1.6S+L LRFD07: +1.2D+1.2Weight+1.6S+0.5W LRFD08: +1.2D+1.2Weight+1.6S-0.5W LRFD09: +1.2D+1.2Weight+W+L+0.5Lr LRFD10: +1.2D+1.2Weight-W+L+0.5Lr LRFD11: +1.2D+1.2Weight+W+L+0.5S LRFD12: +1.2D+1.2Weight-W+L+0.5S LRFD13: +1.2D+1.2Weight+Eh+L+0.2S+0.21D+0.21Weight Page 193 of 213 LRFD14: +1.2D+1.2Weight-Eh+L+0.2S+0.21D+0.21Weight LRFD15: +0.9D+0.9Weight+Eh-0.21D-0.21Weight LRFD16: +0.9D+0.9Weight-Eh-0.21D-0.21Weight LRFD17: +0.9D+0.9Weight+W LRFD18: +0.9D+0.9Weight Combination 2 results: Envelop φMn_Po φMn_Ne φVn 0.5 1.538225 -1.32395 0.2 -0.14 21.65 21.65 18.8 9 Ok Ok 0.08 0.01 3.3 0.783972 5 -0.45395 2 -0.56 21.65 21.65 18.8 9 Ok Ok 0.04 0.09 7.4 5 1.08705 - 1.376027 5 0.35 -0.21 21.65 21.65 18.8 9 Ok Ok 0.07 0.02 2.2 0.593972 5 -0.07395 1.71 -0.83 21.65 21.65 18.8 9 Ok Ok 0.03 0.08 H =24 h =22 bf =16 bw =16 tf =5 Yt = (h✕bw✕h/2+Max(0,(bf-bw)✕tf✕tf/2))/(h✕bw+Max(0,(bf-bw)✕tf))= 11 in Yb = h-Yt11 in I = bw✕h✕h✕h/12+h✕bw✕(h/2-Yt)✕(h/2-Yt)+Max(0,(bf-bw))✕tf✕tf✕tf/12+Max(0,(bf-bw))✕tf✕(tf/2- Yt)✕(tf/2-Yt)= 14197.33 in4 Page 194 of 213 St = I/Yt= 1290.67 in3 Sb = I/Yb= 1290.67 in3 fr = 5√fc= 335.41 psi φMn_Pos=0.6✕(Min(St✕0.85✕f'c, Sb✕fr)/12000) φMn_Neg=0.6✕(Min(St✕fr,Sb✕0.85✕f'c)/12000) φVn=0.6 * (4/3*√fc*bw*h/1000) Page 195 of 213 Sazan Project: 606 Job Ref. 1 Fondansion: LINE C Sheet no./rev R1 Calc. by Eng. Date 2025-07-08 Chk'd by DR.Jalalpour Date 2025-07-08 App'd by DR.Rezaeian Date 2025-07-08 FOOTING ANALYSIS In accordance with ACI318-19 Overall design status PASS Overall design utilisation; 0.685 Description Unit Applied Resisting Utilization Result Soil bearing Ksf 1027.4 1500 0.685 Pass Moment, positive kip_ft 13.28 16.23 0.818 Pass Moment, negative kip_ft 14.97 16.23 0.922 Pass Shear kip 2.135 14.17 0.151 Pass Pad footing details Length of footing L=30 ft Width of footing b=12 in Footing area A=2.5 ft2 Depth of footing H=24 in Density of concrete mass=145 lb/ft3 load case : Eh , W , Lr , Weight , D , L Point loads P (Kip) a (ft) loadCase 2.1 8.5 Eh 2.2 8.5 W -2.1 0.5 Eh -2.2 0.5 W 0.1 8.7 Lr 1.1 9.3 Lr 0.4 16.2 Lr 0.3 22.1 Lr 0.5 27.7 Lr Page 196 of 213 -0.1 8.7 W -1.2 9.3 W -0.4 16.2 W -0.3 22.1 W -0.6 27.7 W Eh W Page 197 of 213 Lr Distributed Loads W1 (Kip/ft) W2 (Kip/ft) a (ft) b (ft) loadCase 0.47 0.47 0 30 Weight 0.24 0.24 0 22.25 D 0.02 0.02 0 22.25 Lr 0.15 0.15 0 22.25 L 0.29 0.29 22.25 30 D 0.02 0.02 22.25 30 Lr 0.28 0.28 22.25 30 L Footing analysis for soil and stability Load combinations per ASCE 7-16 ASD01: +D+Weight ASD02: +D+Weight+L ASD03: +D+Weight+Lr ASD04: +D+Weight+S ASD05: +D+Weight+0.75L+0.75Lr ASD06: +D+Weight+0.75L+0.75S ASD07: +D+Weight+0.6W ASD08: +D+Weight+0.75L+0.45W+0.75Lr ASD09: +D+Weight+0.75L+0.45W+0.75S ASD10: +D+Weight+0.14D+0.14Weight+0.7Eh Page 198 of 213 ASD11: +D+Weight+0.11D+0.11Weight+0.525Eh+0.75L+0.75S ASD12: +0.6D+0.6Weight-0.14D-0.14Weight+0.7Eh ASD13: +D+Weight+0.14D+0.14Weight-0.7Eh ASD14: +D+Weight+0.11D+0.11Weight-0.525Eh+0.75L+0.75S ASD15: +0.6D+0.6Weight-0.14D-0.14Weight-0.7Eh Load Combinations q max q min q allowed Check Bearing Stress L/6 e L' ASD01 749.12 695.44 1500 OK 5 0.2 0 ASD02 1006.5 804.77 1500 OK 5 0.57 0 ASD03 862.79 781.74 1500 OK 5 0.26 0 ASD04 749.12 695.44 1500 OK 5 0.2 0 ASD05 1027.4 842.16 1500 OK 5 0.51 0 ASD06 942.15 777.44 1500 OK 5 0.49 0 ASD07 756.48 584.08 1995 OK 5 0.66 0 ASD08 1032.92 758.64 1995 OK 5 0.78 0 ASD09 947.67 693.92 1995 OK 5 0.79 0 ASD10 932.4 714.41 1995 OK 5 0.67 0 ASD11 1083.36 795.14 1995 OK 5 0.78 0 ASD12 423 241.5 1995 OK 5 1.38 0 ASD13 871.21 775.6 1995 OK 5 -0.28 0 ASD14 965.76 912.74 1995 OK 5 0.15 0 ASD15 398.3 266.2 1995 OK 5 -0.98 0 ASD05 FOOTING DESIGN In accordance with ACI318-19 Material details Compressive strength of concrete f'c = 4500 psi Concrete type Normal Analysis and design of concrete footing Load combinations per ASCE 7-16 Page 199 of 213 LRFD01: +1.4D+1.4Weight LRFD02: +1.2D+1.2Weight+1.6L+0.5Lr LRFD03: +1.2D+1.2Weight+1.6Lr+L LRFD04: +1.2D+1.2Weight+1.6Lr+0.5W LRFD05: +1.2D+1.2Weight+1.6Lr-0.5W LRFD06: +1.2D+1.2Weight+1.6S+L LRFD07: +1.2D+1.2Weight+1.6S+0.5W LRFD08: +1.2D+1.2Weight+1.6S-0.5W LRFD09: +1.2D+1.2Weight+W+L+0.5Lr LRFD10: +1.2D+1.2Weight-W+L+0.5Lr LRFD11: +1.2D+1.2Weight+W+L+0.5S LRFD12: +1.2D+1.2Weight-W+L+0.5S LRFD13: +1.2D+1.2Weight+Eh+L+0.2S+0.21D+0.21Weight LRFD14: +1.2D+1.2Weight-Eh+L+0.2S+0.21D+0.21Weight LRFD15: +0.9D+0.9Weight+Eh-0.21D-0.21Weight LRFD16: +0.9D+0.9Weight-Eh-0.21D-0.21Weight LRFD17: +0.9D+0.9Weight+W LRFD18: +0.9D+0.9Weight Combination 2 results: Envelop X Vmax Vmin Mma x Mmi n φMn_Po s φMn_Ne g φVn Chec k V Chec k M DC R (V) DC R (M) 0. 5 2.10597 5 - 2.1349 5 0.02 -0.03 16.23 16.23 14.1 7 Ok Ok 0.15 0 8. 5 1.5521 - 1.5749 5 13.28 - 14.97 16.23 16.23 14.1 7 Ok Ok 0.11 0.92 0. 5 2.10597 5 - 2.1349 5 0.02 -0.03 16.23 16.23 14.1 7 Ok Ok 0.15 0 8. 5 1.5521 - 1.5749 5 13.28 - 14.97 16.23 16.23 14.1 7 Ok Ok 0.11 0.92 Page 200 of 213 H =24 h =22 bf =12 bw =12 tf =4 Yt = (h✕bw✕h/2+Max(0,(bf-bw)✕tf✕tf/2))/(h✕bw+Max(0,(bf-bw)✕tf))= 11 in Yb = h-Yt11 in I = bw✕h✕h✕h/12+h✕bw✕(h/2-Yt)✕(h/2-Yt)+Max(0,(bf-bw))✕tf✕tf✕tf/12+Max(0,(bf- bw))✕tf✕(tf/2-Yt)✕(tf/2-Yt)= 10648 in4 St = I/Yt= 968 in3 Sb = I/Yb= 968 in3 fr = 5√fc= 335.41 psi φMn_Pos=0.6✕(Min(St✕0.85✕f'c, Sb✕fr)/12000) φMn_Neg=0.6✕(Min(St✕fr,Sb✕0.85✕f'c)/12000) φVn=0.6 * (4/3*√fc*bw*h/1000) Page 201 of 213 Sazan 606 1 LINE D R1 Eng. 2024-12-17 DR.Jalalpour 2024-12-17 DR.Rezaeian 2024-12-17 FOOTING ANALYSIS In accordance with ACI318-19 Overall design status PASS Overall design utilization; 0.681 Description Unit Applied Resisting Utilization Result Pad footing details Length of footing L=31 ft Width of footing b=12 in Footing area A=2.58 ft2 Depth of footing H=24 in Density of concrete mass=145 lb/ft3 load case : Eh , W , Lr , Weight , D , L Point loads -0.7 8.6 Eh -0.8 8.6 W 0.7 22.1 Eh 0.8 22.1 W 0.07 1.7 Lr 0.07 8.2 Lr 0.4 9.7 Lr 0.3 13.1 Lr 0.02 15.2 Lr Page 202 of 213 0.02 17.3 Lr 0.1 22.5 Lr 0.3 22.8 Lr 0.5 29.3 Lr -0.07 1.7 W -0.07 8.2 W -0.4 9.7 W -0.3 13.1 W -0.02 15.2 W -0.02 17.3 W -0.1 22.5 W -0.3 22.8 W -0.5 29.3 W Eh W Page 203 of 213 Lr Distributed Loads 0.47 0.47 0 31 Weight 0.28 0.28 0 22.5 D 0.02 0.02 0 22.5 Lr 0.07 0.07 0 22.5 L 0.32 0.32 22.5 31 D 0.08 0.08 22.5 31 Lr 0.17 0.17 22.5 31 L Footing analysis for soil and stability Load combinations per ASCE 7-16 ASD01: +D+Weight ASD02: +D+Weight+L ASD03: +D+Weight+Lr ASD04: +D+Weight+S ASD05: +D+Weight+0.75L+0.75Lr ASD06: +D+Weight+0.75L+0.75S ASD07: +D+Weight+0.6W ASD08: +D+Weight+0.75L+0.45W+0.75Lr ASD09: +D+Weight+0.75L+0.45W+0.75S ASD10: +D+Weight+0.14D+0.14Weight+0.7Eh Page 204 of 213 ASD11: +D+Weight+0.11D+0.11Weight+0.525Eh+0.75L+0.75S ASD12: +0.6D+0.6Weight-0.14D-0.14Weight+0.7Eh ASD13: +D+Weight+0.14D+0.14Weight-0.7Eh ASD14: +D+Weight+0.11D+0.11Weight-0.525Eh+0.75L+0.75S ASD15: +0.6D+0.6Weight-0.14D-0.14Weight-0.7Eh Load Combinations q max q min q allowed Check Bearing Stress L/6 e L' ASD05 FOOTING DESIGN In accordance with ACI318-19 Material details Compressive strength of concrete f'c = 4500 psi Concrete type Normal Analysis and design of concrete footing Load combinations per ASCE 7-16 Page 205 of 213 LRFD01: +1.4D+1.4Weight LRFD02: +1.2D+1.2Weight+1.6L+0.5Lr LRFD03: +1.2D+1.2Weight+1.6Lr+L LRFD04: +1.2D+1.2Weight+1.6Lr+0.5W LRFD05: +1.2D+1.2Weight+1.6Lr-0.5W LRFD06: +1.2D+1.2Weight+1.6S+L LRFD07: +1.2D+1.2Weight+1.6S+0.5W LRFD08: +1.2D+1.2Weight+1.6S-0.5W LRFD09: +1.2D+1.2Weight+W+L+0.5Lr LRFD10: +1.2D+1.2Weight-W+L+0.5Lr LRFD11: +1.2D+1.2Weight+W+L+0.5S LRFD12: +1.2D+1.2Weight-W+L+0.5S LRFD13: +1.2D+1.2Weight+Eh+L+0.2S+0.21D+0.21Weight LRFD14: +1.2D+1.2Weight-Eh+L+0.2S+0.21D+0.21Weight LRFD15: +0.9D+0.9Weight+Eh-0.21D-0.21Weight LRFD16: +0.9D+0.9Weight-Eh-0.21D-0.21Weight LRFD17: +0.9D+0.9Weight+W LRFD18: +0.9D+0.9Weight Combination 2 results: Envelop φMn_Po φMn_Ne φVn 22.4 5 1.1545 - 0.533125 2.23 -4.11 16.23 16.23 14.1 7 Ok Ok 0.08 0.25 22.1 1.0945 - 0.523125 2.41 -4.5 16.23 16.23 14.1 7 Ok Ok 0.08 0.28 13.1 5 0.59687 5 -0.9767 0.49 -3 16.23 16.23 14.1 7 Ok Ok 0.07 0.18 20.4 0.5545 - 0.247062 5 1.91 -4.77 16.23 16.23 14.1 7 Ok Ok 0.04 0.29 Page 206 of 213 H =24 h =22 bf =12 bw =12 tf =5 Yt = (h✕bw✕h/2+Max(0,(bf-bw)✕tf✕tf/2))/(h✕bw+Max(0,(bf-bw)✕tf))= 11 in Yb = h-Yt11 in I = bw✕h✕h✕h/12+h✕bw✕(h/2-Yt)✕(h/2-Yt)+Max(0,(bf-bw))✕tf✕tf✕tf/12+Max(0,(bf-bw))✕tf✕(tf/2- Yt)✕(tf/2-Yt)= 10648 in4 St = I/Yt= 968 in3 Sb = I/Yb= 968 in3 fr = 5√fc= 335.41 psi φMn_Pos=0.6✕(Min(St✕0.85✕f'c, Sb✕fr)/12000) φMn_Neg=0.6✕(Min(St✕fr,Sb✕0.85✕f'c)/12000) φVn=0.6 * (4/3*√fc*bw*h/1000) Page 207 of 213 Sazan 606 1 PAD-C-3 R1 Eng. 2024-12-15 DR.Jalalpour 2024-12-15 DR.Rezaeian 2024-12-15 FOOTING ANALYSIS In accordance with ACI318-19 Overall design status PASS Overall design utilization; 0.84 Description Unit Applied Resisting Utilization Result Pad footing details Length of footing L=2 ft Width of footing b=18 in Footing area A=0.25 ft2 Depth of footing H=24 in Density of concrete mass=145 lb/ft3 load case : D , Lr , W , Weight Point loads 1.3 1 D 1.6 1 Lr -1.7 1 W Page 208 of 213 D Lr W Distributed Loads Page 209 of 213 W1 (Kip/ft) W2 (Kip/ft) a (ft) b (ft) loadCase 0.43 0.43 0 2 Weight Footing analysis for soil and stability Load combinations per ASCE 7-16 ASD01: +D+Weight ASD02: +D+Weight+L ASD03: +D+Weight+Lr ASD04: +D+Weight+S ASD05: +D+Weight+0.75L+0.75Lr ASD06: +D+Weight+0.75L+0.75S ASD07: +D+Weight+0.6W ASD08: +D+Weight+0.75L+0.45W+0.75Lr ASD09: +D+Weight+0.75L+0.45W+0.75S ASD10: +D+Weight+0.14D+0.14Weight+0.7Eh ASD11: +D+Weight+0.11D+0.11Weight+0.525Eh+0.75L+0.75S ASD12: +0.6D+0.6Weight-0.14D-0.14Weight+0.7Eh ASD13: +D+Weight+0.14D+0.14Weight-0.7Eh ASD14: +D+Weight+0.11D+0.11Weight-0.525Eh+0.75L+0.75S ASD15: +0.6D+0.6Weight-0.14D-0.14Weight-0.7Eh Load Combinations q max q min q allowed Check Bearing Stress L/6 e L' Page 210 of 213 ASD12 334.5 324.61 1995 OK 0.33 0 0 ASD13 828.97 804.46 1995 OK 0.33 0 0 ASD14 807.16 783.29 1995 OK 0.33 0 0 ASD15 334.5 324.61 1995 OK 0.33 0 0 ASD03 FOOTING DESIGN In accordance with ACI318-19 Material details Compressive strength of concrete f'c = 4500 psi Concrete type Normal Analysis and design of concrete footing Load combinations per ASCE 7-16 LRFD01: +1.4D+1.4Weight LRFD02: +1.2D+1.2Weight+1.6L+0.5Lr LRFD03: +1.2D+1.2Weight+1.6Lr+L LRFD04: +1.2D+1.2Weight+1.6Lr+0.5W LRFD05: +1.2D+1.2Weight+1.6Lr-0.5W LRFD06: +1.2D+1.2Weight+1.6S+L LRFD07: +1.2D+1.2Weight+1.6S+0.5W LRFD08: +1.2D+1.2Weight+1.6S-0.5W LRFD09: +1.2D+1.2Weight+W+L+0.5Lr LRFD10: +1.2D+1.2Weight-W+L+0.5Lr LRFD11: +1.2D+1.2Weight+W+L+0.5S LRFD12: +1.2D+1.2Weight-W+L+0.5S LRFD13: +1.2D+1.2Weight+Eh+L+0.2S+0.21D+0.21Weight LRFD14: +1.2D+1.2Weight-Eh+L+0.2S+0.21D+0.21Weight LRFD15: +0.9D+0.9Weight+Eh-0.21D-0.21Weight Page 211 of 213 LRFD16: +0.9D+0.9Weight-Eh-0.21D-0.21Weight LRFD17: +0.9D+0.9Weight+W LRFD18: +0.9D+0.9Weight Combination 2 results: Envelop φMn_Po φMn_Ne φVn 0.9 5 2.3629 - 0.25032 5 1.12 -0.12 24.35 24.35 21.2 5 Ok Ok 0.11 0.05 1 0.26967 5 -2.4771 1.25 -0.13 24.35 24.35 21.2 5 Ok Ok 0.12 0.05 1 0.26967 5 -2.4771 1.25 -0.13 24.35 24.35 21.2 5 Ok Ok 0.12 0.05 1 0.26967 5 -2.4771 1.25 -0.13 24.35 24.35 21.2 5 Ok Ok 0.12 0.05 H =24 h =22 bf =18 bw =18 tf =0.1 Yt = (h✕bw✕h/2+Max(0,(bf-bw)✕tf✕tf/2))/(h✕bw+Max(0,(bf-bw)✕tf))= 11 in Yb = h-Yt11 in I = bw✕h✕h✕h/12+h✕bw✕(h/2-Yt)✕(h/2-Yt)+Max(0,(bf-bw))✕tf✕tf✕tf/12+Max(0,(bf-bw))✕tf✕(tf/2- Yt)✕(tf/2-Yt)= 15972 in4 St = I/Yt= 1452 in3 Sb = I/Yb= 1452 in3 Page 212 of 213 fr = 5√fc= 335.41 psi φMn_Pos=0.6✕(Min(St✕0.85✕f'c, Sb✕fr)/12000) φMn_Neg=0.6✕(Min(St✕fr,Sb✕0.85✕f'c)/12000) φVn=0.6 * (4/3*√fc*bw*h/1000) Page 213 of 213 SANTA ANA CITY COUNCIL Mayor vamezcua@santa-ana.org Mayor Pro Tem - Ward 2 bvazquez@santa-ana.org Ward 1 tphan@santa-ana.org Ward 3 jessielopez@santa-ana.org Ward 4 pbacerra@santa-ana.org Ward 5 jryanhernandez@santa-ana.org Ward 6 dpenaloza@santa-ana.org MAYOR Valerie Amezcua MAYOR PRO TEM Benjamin Vazquez COUNCILMEMBERS Phil Bacerra Johnathan Ryan Hernandez Jessie Lopez David Penaloza Thai Viet Phan CITY OF SANTA ANA PLANNING AND BUILDING AGENCY 20 Civic Center Plaza ● P.O. Box 1988 Santa Ana, California 92702 www.santa-ana.org CITY MANAGER Alvaro Nuñez CITY ATTORNEY Sonia R. Carvalho CITY CLERK Jennifer L. Hall April 7, 2025 Also sent via email to: teditakeuchi@yahoo.com Tetsuya Takeuchi, 27801 Manor Hill Road, Laguna Niguel, CA 92677 Subject: Address Assignment for a new detached Accessory Dwelling Unit (ADU)located at 606 S. Van Ness Avenue (010-163-09) in Santa Ana, CA Dear Tetsuya Takeuchi, The City of Santa Ana Planning and Building Agency (PBA) is the responsible agency for legal addressing within the City of Santa Ana’s jurisdiction. This letter confirms the address assignment for a new detached ADU located at 606 S. Van Ness Avenue (010-163-09). Notice is hereby given that the following assigned address(es) shall be posted onsite per the approved address plan, attached hereto as Exhibit A. Address(es) to be Activated/Posted To subdivide commercial and/or residential units into multiple units, a building permit (and all other associated permits), plans, and inspection approvals by the PBA are required. Address(es) will be verified during inspections by the Building Safety Division. Please update your records accordingly. Should you have any questions, feel free to contact me by phone at 714-667-2728 or by email at CSantana@santa-ana.org. Sincerely, Cristian Santana Cristian Santana, Assistant Planner II Address Letter for 606 S. Van Ness Avenue Page 2 of 2 Exhibit A – Address Plan c: Kris K Chu, Santa Ana Manager, United States Post Office Fernando Banuelos, Fountain Valley Manager, United States Post Office Yesenia Torres, Santa Ana Manager, United States Post Office Enrique Ponce, Sna-North Grand Sta Manager, United States Post Office Esthephany Treto Ramirez, Admin Supervisor, United States Post Office Chris Tuiolosega, United States Post Office Alex Alvarez, Santa Ana Postmaster, United States Post Office Federal Express, Administration Cathy Joseph, Garden Grove Unified School District Christine Hy, Garden Grove Unified School District Cathy Slader, Orange Unified School District Ted Walstrom, Santa Ana Unified School District Jeremy Cogan, Santa Ana Unified School District Yvette Miranda, Santa Ana Unified School District Cristina Bernal, Tustin Unified School District Orange County Fire Authority Neal Kelly, Registrar of Voters Members, Board of Supervisors Southern California Gas Company Southern California Edison Company Claude Parrish, County Assessor's Office GIS SAG, AT&T UPS, Administration City Manager’s Office Beverly Martin, Police Community Services Specialist Boris Duran, Police Systems Manager Jennifer Arellano, Police Communications Manager Chris Hubbard, Police Systems Support Analyst Alejandra Gutierrez, Treasury & Customer Services Manager Hector Jimenez, Revenue Supervisor Alfonso Chavez, Utilities Customer Services Supervisor Judson Brown, Housing Division Manager Rudy Rosas, Deputy Public Works Director / City Engineer Zdenek (Zed) Kekula, Principal Civil Engineer Jason Kwak, Building Safety Manager Evelyn LaRocca, Permit Services Principal Kathy Hernandez, Permit Technician Julie Amsden, Permit Technician Ricardo Soto, Acting Planning Manager Jerry Guevara, Senior Planner Yvette Portugal, Code Enforcement Manager Jerry Navarro, Code Enforcement Principal (E) DRIVEWAY APN : 01016309 NO : 606 (E) CONCRETE SLAB (E) ELECTRICAL PANEL 100 AMPS S V A N N E S S P. L . 5 6 . 3 ' (E) GARAGE UP UP (E) COVERED PORCH (E) WOOD FENCE, 6' H. (E) BLOCK FENCE, 6' H. (E) COVERED PATIO ADU 730 SF LAWN LAWN (E) LANDSCAPE (E) LANDSCAPE (E) TREE P. L . 5 6 . 3 ' P.L. 125' P.L. 125' 4" / 1'-0"4" / 1'-0" 6" / 1 ' - 0 " 6" / 1 ' - 0 " 4" / 1 ' - 0 " 4" / 1 ' - 0 " 2" / 1 ' - 0 " WATER METER (E) GAS METER (E) TREE (E) WOOD FENCE 36" H. (E) WOOD FENCE 36" H. EXISTING HOUSE (E) AC UNIT 10'-7" N.I.C 4" / 1 ' - 0 " 4" / 1 ' - 0 " N.I.C 4" / 1'-0"4" / 1'-0" 4" / 1 ' - 0 " 4" / 1 ' - 0 " SE T B A C K 25 ' - 3 " SETBACK 5'-0" WALL SEPARATION 15'-0" WA L L S E P A R A T I O N 15 ' - 9 " SE T B A C K 5' - 0 " SETBACK 4'-0" SE T B A C K 4' - 0 " SE T B A C K 24 ' - 3 " 1' - 0 " (N) CONCRETE PAD(N) WALK WAY ENTRY (E) AVOCADO TREE HAS BEEN APPROVED UNDER SEPARATE PERMIT 4' - 0 " 4'-0" (N) 1GL. SHURBS 24”BOX CANOPY TREE (N) 5GL. SHURBS 24”BOX CANOPY TREE (N) 5GL. SHURBS (N) 1GL. SHURBS (N) 1GL. SHURBS (N) 1GL. SHURBS HARDSCAPE/PAVEMENT PA T H O F T R A V E L PATH OF TRAVEL (N) SANDBAGS (N) SANDBAGS THE GRADE SHALL FALL NOT FEWER THAN 6IN WITHIN THE FIRST 10FT. WHERE LOT LINES, WALLS, SLOPES OR OTHER PHYSICAL BARRIERS PROHIBIT 6IN OF FALL WITHIN 10FT, DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE.IMPERVIOUS SURFACES WITHIN 10FT OF THE BUILDING FOUNDATION SHALL BE SLOPED NOT LESS THAN 2% AWAY FOR THE BUILDING PER 2022 CRC, SECTION R401.3. EXISTING 4" D SEWER LINE NEW 4" D SEWER LINE (E) CLEANOUT CITY LATERAL(E) CLEANOUT NEW CLEANOUT SE D I M E N T B A R R I E R (N) SANDBAGS 5% SLOPE 2% SLOPE 5% 5% 5% 5% SLOPE 5% SLOPE 2% SLOPE 2% SLOPE 2%THE PROPOSED ROOF SHINGLES MATCHES THE PRIMARY DWELLING UNIT MATERIAL, STYLE, AND COLOR. NOTE: LOCATION OF DS CONNECT TO EXISTING DRAINS/ STORMWATE GALVANIZED STEEL HALF ROUND DORMER VENT. REFER TO ATTIC CALCULATION ROOF VENT W/ SCREEN ROOF VENTS W/ WIRE MESH OF LESS THAN 1/4" OPENING 2.84 2.84 2.84 2.84 2.84 DOWNSPOUT GRAY AREA: PROTECT UNDERSIDE OF EAVE WITH 1-HOUR PROTECTION AND NO EAVE VENTS. TYPE X GYPSUMSHEATHING UNDER SOFFIT AND WALL MATERIAL (TYP.) 1'-0" 1' - 0 " 1'-0"ENCLOSURE OF TANKLESS W.H. 199,000BTU MINI SPLIT ELECTRICAL SUB PANEL 100A ASPHALT SHINGLE CLASS A ESR 1475 TWO LAYERS OF UNDERLAYMENT INSTALLED PER CRC TBL. R905.1.1(2) (E ) S I D E S E T B A C K 5' - 0 " (E ) S E T B A C K 1' - 9 " (E ) S I D E S E T B A C K 14 ' - 1 1 " WALL SEPARATION 3'-0" WALL SEPARATION 5'-0" (E) FRONT SETBACK 27'-0" (E) REAR SETBACK 42'-9 1/2" (N)CANOPY TREES (E) GARAGE FRONT SETBACK 63'-9" (N)CANOPY TREES WATER HEATER VENT 1'-0" 1' - 0 " 1'-0" 1' - 0 " 1'-0" 1'-0" 1' - 0 " 1' - 0 " 1'-0" 1' - 0 " 1'-0" (E) CRAWL SPACE ACCESS DOOR (E) SETBACK 41'-0" 3' - 0 " 2'-6" 2' - 6 " 2.84 RIDGE VALL E Y RI D G E VAL L EY A5.0 9 A5.0 9 2'-8" 2' - 3 " 1'-0" 1' - 0 " 1'-0" 1' - 6 " 1" C O P P E R P I P E RI G I D N O N - M E T A L L I C EL E C T R I C A L C O N D U I T 4" N O N - M E T A L L I C S E W E R L I N E SEWER LINES -EXISTING AND PROPOSED NEW LINES: 4" PVC SANITARY LINE WITH 1/4" - 1' MIN. FALL. JOINTS AND INSPECTIONS POINTS TO COMPLY WITH APPLICABLE CODES W W WATER LINES -EXISTING AND PROPOSED NEW LINES: 3/4" PVC WATER LINE. PIPES, JOINTS AND CONNECTIONS TO COMPLY WITH APPLICABLE CODES GAS LINES -EXISTING AND PROPOSED NEW LINES: 3/4" NATURAL GAS SUPPLY LINES. PIPES, JOINTS AND CONNECTIONS TO COMPLY WITH RELEVANT CODES G G ELECTRICAL SERVICE LINE TO ADUEE COAX/DATA SERVICE LINE TO ADUDD EXISTING WALLS TO REMAIN PROPOSED WALLS LANDSCAPE (PERMEABLE) CONCRETE SURFACE (IMPERMEABLE) TILE SURFACE (PERMEABLE) GRAVEL (PERMEABLE) W E G UTILITY METERS AND SHUT-OFFS: WATER, ELECTRICAL, GAS SHUT-OFF VALVE WASTE LINE CLEANOUT DATE: P.M.: DRAWN BY: JOB NO.: 26081 Merit Cir, STE 111 Laguna Hills, CA 92653 909-257-7040 WWW.BNDESIGNBUILDINC.COM THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. DES I GN B U I L D CNI 12 / 2 5 / 2 0 2 4 3 : 1 5 : 0 0 P M A1.1 B.N. F.M. PROPOSED SITE PLAN 07.11.24 2024001108 UNIT 2, 606 S VAN NESS AVE, SANTA ANA, CA 92701 ACCESSORY DWELLING UNIT 4 21 NO R T H 0 2'-8"5'-4"10'-8" SCALE: 3/16" = 1'-0" 1 4 3 6 5 5 5 7 9 10 3/16" = 1'-0"1 PROPOSED SITE PLAN 1. PROPOSED ADU TO BE LOCATED IN THE REAR YARD AS INDICATED ON THE SITE PLAN. 2. ALL LEVELS, DIMENSIONS AND ANGLES HAVE TO BE CHECKED AND VERIFIED PRIOR TO COMMENCING ANY WORK ON SITE. VERIFICATION SHALL INCLUDE, BUT NOT BE LIMITED TO: A. MIN. SETBACKS TO PROPERTY LINES AS INDICATED ON THE SITE PLAN. 3. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED TO BE INSTALLED IN RESIDENTIAL GROUP R OCCUPANCIES WHEN ALTERATIONS, REPAIRS, OR ADDITIONS REQUIRING A BUILDING PERMIT OCCUR. SMOKE AND CARBON MONOXIDE ALARMS SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS, AND APPLICABLE PROVISIONS OF CBC, CRC, CFC, AND COUNTY OR MUNICIPAL STANDARDS. ADDRESS IDENTIFICATION NOTES: 1. ADDRESS SPEC - THE ADDRESS IDENTIFICATION CHARACTERS SHALL CONTRAST WITH THEIR BACKGROUND, AND EACH CHARACTER SHALL BE NOT LESS THAN 4-INCHES IN HEIGHT WITH A STROKE WIDTH OF NOT LESS THAN 0.5- INCH. PUBLIC RIGHT OF WAY: 1. THERE IS AN EXISTING CURB CUT FOR THE PROPERTY, TO REMAIN. THE PROJECT DOES NOT INCLUDE ANY WORK IN THE PUBLIC RIGHT OF WAY. UTILITIES: 1. UTILITY CONNECTIONS ARE INDICATED ON THE SITE PLAN AND LABELED. 2. THE PROJECT CONTACT AND/OR THEIR LICENSED CONTRACTOR SHALL CONFIRM THE LOCATION, SIZE AND CAPACITY OF ALL UTILITY LINES INCLUDING, BUT NOT LIMITED TO, GAS SERVICE, WATER SERVICE, SEWER/WASTE SERVICE, ELECTRICITY AND DATA SERVICE. THE PROPOSED SERVICE CONNECTIONS FOR THE ADU SHALL BE VERIFIED AND DETERMINED TO BE VIABLE CONNECTION PATHS PRIOR TO COMMENCING WORK ON THE PROJECT. IF ANY REQUIRED UTILITY LINE OR CONNECTION IS MISSING, DISPLACED OR OTHERWISE INACCURATE, THE CONTRACTOR AND/OR PROJECT CONTACT SHALL NOTIFY ALL PARTIES AND A REVISION TO THE PLANS SHALL BE MADE. 3. WATER SUPPLY: ADU TO BE CONNECTED TO THE COLD WATER SUPPLY TO THE PRIMARY HOME. 4. SEWER: ADU TO BE CONNECTED THE SEWER LINE ON THE PROPERTY. 5. ELECTRICAL ENERGY: PROVIDE MAIN SWITCH FOR THE ADU IN THE MAIN HOUSE ELECTRICAL PANEL BOARD. INSTALL ELECTRICAL PANEL IN THE ADU. 6. GAS: ADU TO BE CONNECTED TO THE GAS SUPPLY TO THE PRIMARY HOME. 7. WATER MAINS AND SERVICES, INCLUDING METERS, MUST BE LOCATED AT LEAST 10' HORIZONTALLY FROM OR AT LEAST 1' VERTICALLY ABOVE ANY PARALLEL PIPELINE CONVEYING UNTREATED SEWAGE (SEWER LATERAL). CALIFORNIA WATERWORKS STANDARDS, TITLE 22, CHAPTER 16, SECTION 64572. GENERAL SITE PLAN NOTES: DRAINAGE NOTES: 1. RAINWATER DISTRIBUTION OVER PERMEABLE AREA ON THE PROPERTY. 2. GRADING TO SLOPE 5% AWAY FROM THE WALLS, FOR MIN. 10'. WHERE LESS THAN 10' SPACE IS AVAILABLE - SEE BELOW. 3. SWALES ALONG SIDE WALLS OF THE ADU TO DIVERT STORMWATER TO THE STREET. 4. SWALES ALONG SIDE WALLS OF THE ADU TO DIVERT STORMWATER OVER PERMEABLE AREA ON THE PROPERTY (LANDSCAPE). SITE PREPARATION NOTES: 1. TAKE NECESSARY PRECAUTIONS TO MINIMIZE DISTURBANCE OF EXISTING VEGETATION TO REMAIN. 2. SOIL DISTURBANCE SHALL BE LIMITED TO THAT WHICH IS NECESSARY FOR SITE PREPARATION AS DESCRIBED IN THIS SECTION INCLUDING UTILITY CONNECTIONS. PREVENT WATER FROM RUNNING INTO EXCAVATED AREAS. 3. BACKFILL MATERIAL SHALL BE FREE OF ORGANIC MATTER AND ROCKS OR LUMPS OVER 6 INCHES (2 INCHES AT UTILITY TRENCHES). COMPACT BACKFILL TO AT LEAST 90 PERCENT RELATIVE COMPACTION PER ASTM D-1557; IN LIFTS NOT EXCEEDING 8 INCHES UNCOMPACTED. 4. DEPRESSION FROM REMOVAL OF OBSTRUCTIONS SHALL BE OPENED TO WORKING SIZE; REMOVE DEBRIS AND SOFT MATERIAL; BACKFILL AND COMPACT AS NECESSARY. 5. SURFACE DRAINAGE SHALL SLOPE 3% FROM BUILDING FOUNDATIONS FOR A MINIMUM OF 5 FEET AND AT LEAST 1% TO SUITABLE COLLECTION POINTS. 6. TRENCHING SHALL BE TRUE TO GRADES INDICATED. EXTEND UTILITY TRENCHES TO BE SUFFICIENT DEPTH STANDARDS AND LOCAL CODES. PROPERLY SUPPORT TRENCHES. 7. UNUSUAL CONDITIONS NOT COVERED IN THE PROJECT, IF ENCOUNTERED, SHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT'S CONTACT AND RESOLVED ACCORDING TO APPLICABLE CODES. 8. IF DEEMED NECESSARY, HAZARDOUS WASTE TESTING SHALL BE CONDUCTED INCLUDING ASBESTOS TESTING & REMEDIATION. 9. STORM WATER DRAINAGE AND RETENTION SHALL BE FURNISHED DURING CONSTRUCTION. MEANS OF DRAINAGE AND RETENTION AS FOLLOWS: A. STORM WATER CONVEYED TO A PUBLIC DRAINAGE SYSTEM SHALL BE FILTERED BY A BARRIER SYSTEM, WATTLES OR OTHER APPROVED METHOD. B. IMPLEMENT STORM WATER MANAGEMENT METHODS PER THE JURISDICTION'S MUNICIPAL CODE, ORDINANCE, OR OTHER REQUIREMENTS. C. GRADING AND PAVING SHALL BE CONDUCTED TO MANAGE SURFACE WATER INCLUDE SWALES, WATER COLLECTION AND DISPOSAL SYSTEMS, FRENCH DRAINS, WATER RETENTION GARDENS OR OTHER MEASURES AS INDICATED OR NECESSARY TO KEEP SURFACE WATER AWAY FROM BUILDINGS AND AID IN GROUNDWATER RECHARGE. 10. AVOID LAND-DISTURBING WORK DURING ANY WET WEATHER SEASON. PROJECT CONTACT TO VERIFY CLIMATE AND WEATHER FORECASTS PRIOR TO COMMENCING THE LAND- DISTURBING WORK. 11. EXISTING VEGETATION TO REMAIN SHALL BE PROTECTED, INSTALL APPROPRIATE/PROTECTIVE FENCING/PERIMETER CONTROLS PRIOR TO COMMENCING WORK. 12. ALL IMPERVIOUS SURFACES SHALL BE SWEPT (NOT WASHED OR HOSED DOWN), AND MAINTAINED FREE OF DEBRIS AND ACCUMULATIONS OF DIRT. 13. ALL CONSTRUCTION WASTE SHALL BE CONTAINED ON SITE AND COVERED, INCLUDING TRASH, PAINT, GROUT, CONCRETE, ETC. ANY WASH OUT FACILITY SHALL BE CONTAINED, MAINTAINED, AND ITS CONTENTS DISPOSED OF PROPERLY; NO MATERIAL SHALL BE WASHED INTO THE STREET. 14. CATCH BASINS AND/OR DROP INLETS THAT RECEIVE STORM WATER MUST BE COVERED OR OTHERWISE PROTECTED FROM RECEIVING SEDIMENT, MUD, DIRT, OR ANY DEBRIS, INCLUDING PRIOR GUTTER FILTRATION AS APPROPRIATE AND IN A MANNER NOT IMPEDING TRAFFIC SAFETY. 15. PROPERLY INSTALLED SILT FENCE OR EQUIVALENT CONTROL SHALL BE EVIDENT ALONG SITE PERIMETER TO PREVENT MOVEMENT OF SEDIMENT AND DEBRIS OFF-SITE. NO SEDIMENT MAY LEAVE OR RUNOFF THE SITE. PROJECT CONTACT SHALL VERIFY, IF APPLICABLE, IF ADDITIONAL SLOPE STABILIZATION BMPS SHALL BE IMPLEMENTED TO PREVENT SLOPE EROSION AND SEDIMENTATION ON-SITE AND OFF. 16. ALL STOCKPILES SHALL BE CONTAINED AND COVERED WHEN NOT ACTIVE, AND SECURED AT THE END OF EACH DAY. STOCKPILES SHALL BE SECURELY COVERED OVERNIGHT, AND PRIOR TO, DURING, AND AFTER RAIN EVENTS. NO MATERIALS SHALL LEAVE THE SITE OR BE MOVED INTO THE STREET. 17. PROJECT CONTACT AND SUBCONTRACTORS MUST ENSURE ALL CONSTRUCTION VEHICLES AND EQUIPMENT ARE MAINTAINED IN WORKING ORDER, AND WILL NOT CAUSE DIRT, MUD, OIL, GREASE, OR FUEL TO BE DISCHARGED OR TRACKED OFF-SITE INTO THE STREET. SITE KEYNOTES 1 EXISTING CONCRETE PAD 2 WATER METER 3 EXISTING ELECTRICAL PANEL 4 PROPERTY LINE 5 EXISTING WOOD FENCE 6 EXISTING DRIVEWAY 7 EXISTING GAS METER 8 EXISTING GATE 9 EXISTING CRAWL SPACE ACCESS DOOR 10 EXISTING AC UNIT SITE PLAN LEGEND ATTIC VENTILATION CALCULATION UNIT #2 NEW ATTIC SPACE AREA 730 S.F. REQUIRED VENTILATION 730 / 150 = 4.8 NFA SQ. FT. 4.8 X 144 = 691 SQ. INCHES OF NFA (A LEAST 40% MINIMUM FOR RIDEG AND 60% MAXIMUM AT THE UPPER PORTION OF THE ROOF EAVE) 691 40 % 276 SF IN ROOF VENTS 691 60% 414 SF IN EAVE/ROOF VENTS 276 / 60 = 4.6 = 6 ROOF VENT PROVIDED REV DATE REMARKS 1 10.03.2024 City Correction NOTE: THE APPLICANT/PROPERTY OWNER SHALL BE RESPONSIBLE FOR CONFIRMING ALL EXISTING UTILITY EASEMENTS AND CLEARANCE ON- SITE THAT MAY AFFECT THE PROJECT. Unit 2 Exhibit A O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Submittal Criteria Form Required for Single Family or Duplex Residences (Use Commercial form for lots with 3+ dwelling units or new residential tracts) Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification. Project Information  New Single Family Residence/Duplex  Addition/Remodel  ADU  Other Address: Unit #: City or Unincorporated County Area: ZIP: Scope of Work: Existing Area: Area to be Added: Total Resulting Area: Stories: Area Added in Past 2 Years (excluding this project): Yes No Questionnaire OCFA Plan Type if “Yes” 1.   New – Is this a new single family residence or duplex? *(PR160) Residential Site with Water Availability (PR400-402) Fire Sprinkler 2.   ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has fire sprinklers or a house that will have fire sprinklers added as part of this project? (PR400-402) Fire Sprinkler 3.   Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire sprinkler retrofit based on a threshold set by local ordinance? (PR400-402) Fire Sprinkler 4.   Distance – Is the most remote portion of the addition, ADU or other detached structure greater than 140-feet from the fire access roadway? *(PR160) Residential Site 5.   Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non- sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all enclosed spaces, such as garages, stairs, and detached structures separated by less than 10-feet? *(PR160) Residential Site with Water Availability 6.   Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed contractor to determine if a fire sprinkler modification is needed. (PR400-402) Fire Sprinkler 7.   Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold set by local ordinance? *(PR160) Residential Site (PR400-402) Fire Sprinkler 8.   Gate – Is a gate being installed across a driveway or road that is designated as a fire department access roadway, or a driveway or road that serves more than a single home/duplex? (PR180) Gate 9.   Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000 sf, and ADU’s). *(PR160) Residential Site *(PR172-174) Methane Test/Mitigation Plans 10.   Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation, or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as defined by the State, or (D) near an area that could be affected by a wildfire in the open space. *(PR125) Fuel Modification (PR182) Accessory Structure *OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals. Applicant Certification I certify, under penalty of perjury, under the laws of the State of California, that the information above is true: Print Name:_______________________________________ Signature:___________________________________________ Date:______________ Phone Number:_____________________________________________ Email:_____________________________________________________________ Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required. ______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes” and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination. For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100 SFR 3�� o� m 0p�o�3� m �ozo N v o<D j v fro— N�•�,— °�— N n— °— = —� W-,— Nv,o 6� °v ° (D 0 r N n D N r O. O Q Q a (�j) n Z n N N Q 3 U �. (o 3 o CL 0 @ (�D Q N Q (D (DD CL 7 O N N D (CD W (Q O O to (p p Ur h In cQ l] Z p p N 0- o 5- a C1 N ._« CL ¢1 CL --h 0, CL N (D C1 Q. C• q C c cn s �• , o w w - cn O N(n o c ai N CrTI U) ' n (DO w C L (A) (D :3 tU (D CLC N Q G i �, CL Q (fl 6 (fl ZF (D O ( gyp S v y X O (D0 CLN o p O v 77 7 6 �. C Af Z (DU) p O o u) CL =hO- v O•(D (OD 3 D Q-C O(D Q7 (D O C7 N N< q i C r 0- q 3 n Z C C-p C c N (n r« v c p (D (D �� (D 61 N 5) (D ❑ ny 0 v Et3 00 a cvn C iZ N (p C �. N N N U) rr 0 () ,�" C (�D < N C. O O cz O C2 . C a' 0- -+ n C N m cQ 0-0 `< (D c N N r - N u,' N N CL N ° (D c C ((D W n ty (D (D (D (D ? 0 N E3 n o = 3 3 D = C N to N ro C -s O N C2 Ci O 7< 0 c N (D �_ O CL x -q C1 C iS N tU N W N N ()' C` Al N x (D = U) o t7 Q g < "` --1-1 (gyp 3 n a 3 v, ° W (n a �, w m�a t N �O 0 O < W (Q N (D C ,, , N (D v v N C O � „ (� (DV -, (D CL (D -r N ro p' O (D f1 C (D 0 a 0 v. o ro n� -� n (o O C L 0 C CL O Z o �• CL CL o (D N c 3 c: 6 0U) (n o � (D 0 O -� (a 5. ^(D 3(D u �N� of (n V0o r@ N3a�cn o ov �ro o a _ a emu, emu, 30�°� �' � �n -.0 (n O (CD `G (D p) (� r ro v, N a N•ro (D�.a 0 3 3 lD W (n SU N 0- v 0- O CL ID � U) _• O N (n (D in' �' v (D 3 a)(n C O C U?' Z3- CL-n � r1 N C1 C. d �' O cn < O N C 3 3 Z3 (D— N pi a- 5 O W N (D Z X f 0- p) (n N O ro_ N O AJ 0 (Cz N (n C N � C; • 0 < _ (D 0 Q) (7 � 's C N (D N O v ' N Sll C1 3 O —, N n N O C2 C `G 3 N fl1 (D C Q C2 O N Ci O o ((DD �' OC (D v, _= q �� _ 3 _ - c) w o N1 n C �) C U) O N N ill U) N :� (D U) N C 3 3 �, (no0 oo N � UCi (D N p (D N N v 3 (Nn qC N `{+ N to O 6 — q O (OF. (n N ' n U) O C1 Q O `� Q v x sz (D0� <CL n C (D �'0 ' �' �'o00 0 o N' U) L h iS q q ° 7 < C< j (p C' `, N� 3 i _r N lD (D 7 — 0- N (p C. C (D D< Er (Do� om m y�_�' o Ica' (D� � z (o � , N O C 77 7 N .�. -O U1 Q o (D ' uCi N ((D O (D • p) o. Ur g �, u%i O m �- _° - 3 o o 0 w' (D(D 3�_ — (D ° 77 m°(D o �m 0�• a (D Q� N � 6 cD o a v o� ? oa 0z w N o Q m o`o` w m m o (p c�D`< �. N m m oa� a� m m p3i o � W ((/) c o C h O ? N �• C O 3 C O O O O Ol (D O - N C o 3 v (D N C 0 U) 0 -a n m 'G V m m M CITY OF SANTA ANA Planning and Building Agen T Art P n a 7 O, Lfl to (o� w Ro a M co � co C� m o DCOCD c o N� opa (� -4 i N v occ ro s 0 'G NC Z -0 _u :3 — -0 D z -0 to -V 57 m Cn �. o 0- 3 - 0m 0 x n c� (D � (D 0 (D �' o (D O Z v 4 0) m z to o r- o o' °g m (D O 3 D ° 2 o cQ -� 3 (o 5 w o ° a o (A -amz o b0 ro O -ai. a M. O (n rot. @ U_? (D (D a� D N (D a ° c = �' o �,�� (D m O Q- rt M. D (D fl (D p o �Dam mm (D_ wOO aa o u' G O 3 o N mD y �(D (D 7 _1 -a -, O z �. (D o v (D O urn ° o(D ((DD� °a a �= c. o (D " l< o o a m --I m o a► �. * O a �� QQ O z o m (DN o X (p a (D O (D o a rnrn (D '< Z O O y N N N .o o mo m 0 a�i a► (D (D W ^" n n U) �_0 to y�-- /1 a m D 0 o � n (n `� r o v v mlb � p =3 (D I to CL ((DD (D ° iT (D Ql y' ro c o S N (D (D q CITY OF SANTA ANA _ Planning and Building Agency O :T O Or (D ° 7 N U) fD tD O ro m ro -„ � � 0 'o � ,� � �ar; e Q a' E�)R PP51IDI?UANCE ID n r. O (D[Q 9l v N N C: 7 9 ° ew (DO o T Ster I[ n ply (D c�D ao� _ N(a O o o 'o a o_oo-, �a -'0 o(D a� oomty ca =„ o° U) o` N O(DOO fit a`"C:—D� m (a— Cr �, o m -0) 0- a �� o(n i v (Dro v,a o wEP o �'' <a03 `°�(D ~rov s m mo o(D(no 0 7Q vo n° a in < < o' (n aro m a N `G Oo CD rz� a a Q w �'� rn 3 to O� v —� O (D n � C'D N ca 3 : 0 (D n (D C) a (D 7 3 rt C (n Ej a lD a ro 7 !y CD O ro omaoao (D tea• on roo hoa a-,w° o0� - w w: o te3w Cn° °=^<3 Q. (D n3<I( v c � _U) Q (D (D h _ ° j. d � rJ Q, n o- � � a_ � -a � ° � 0 3 W (D 0o ,� w qrL �'O�r,� cz *.�' (D (D0 En ^h 1 -°(Quw—ivy - Q v--o 0Czs ua, aoa(�n a _ 3 �° -w v-l<3No (a (D o3 a o 0-0 (n (D o (D �<'-o am o03 (n v �(Do . tD � _, -; c am E w Q U� 3 rn -p o m(D Z <' a o (n o.° o G o B o� g lG , a. w (n(D ��m ,�,� a � (D JCL (D (D ro (D O ry a_ 7" v (7 (D j cD (D G L) O (D = a O O < 00 C OC (U � -' p CA DO CL .t (D G 7 O a p1 O G (D cD — (D O (D 0 a a ((DD (a (D D N 3 o d m ID �' (D o. v "" O O (DD _ O (D C a h CITY OF SANTA ANA Santa Ana Unified School Disirland Building Agency Approved Project #9371104 - Payment FOR PERMIT ISSUANCE Receipt Master ID: Date: � SAUSD Developer Powered by facilitron Payment Receipt Your payment has been processed! Please note: this is NOT a certificate of compliance. A certificate of compliance will be created once the district has reviewed and approved the request and all fees are paid. Project Number: PRJ-9371104 Job Location / Address: 606 s Van ness ave., 2, Santa Ana, CA, 92701 Payment Info Payer name: Tetsuya Takeuchi Payment method: AMEX ....1010 Payment amount: $4,013.66 Payment date: 12/16/2025 3:04 PM Authorization Code: 222660 Transaction ID: 024d80d8-090a-4862-b764-79f2d4ce4030 Please note that the charge will appear on the card/bank statement as FACILITRON, INC. Thank you, Santa Ana Unified School District and The Facilitron Team For support, please contact developerfees@facilitron.com or 1-800-272-2962 (ext.6)