Loading...
HomeMy WebLinkAbout821 S Ross St - PlanBldg #101124022 APPROVALS: PLNG - C. Santana BLDG - T. Le PUBLIC WORKS - B. Sarlak RESIDENTIAL LIGHTING DESIGN GUIDE NEW WINDOW AND DOOR SCHEDULE CITY OF SANTA ANA �ld+ng Agency ALL NEW CONSTRUCTION SHALL BE DONE IN ACCORDANCE WITH THE 2022 CALIFORNIA BUILDING,PLUMBING,MECHANICAL AND ELECTRICAL CODES, AND ALL LOCAL CODES AND ORDINANCES.ALL WORK SHALL COMPLY WITH THE CALIFORNIA BUILDING STANDARDS CODES FOUND IN THE STATE OF CALIFORNIATITLE 24. LIGHTAND VENTILATION PER CBC SECTION 1202.MINIMUM OF 15 CFM OF OUTSIDE AIR PER OCCUPANT IS REQUIRED FOR VENTILATION. ALL WOOD CONSTRUCTION SHALL COMPLY WITH CODE SEC. 2308 AND MINIMUM NAILING WITH CODE TABLE 2304.9.1 WALLS WITH PLUMBING WILL BE 2X6 STUDS. WALLS AROUND TUB AND SHOWERS TO BE FINISHED WITH HARD NON -ABSORBENT MATERIAL. TO 72" ABOVE DRAIN. A MINIMUM WIDTH OF 30 AND 24 SPACE IN FRONT IS REQUIRED IN ALL TOILETS. ELECTRICAL NOTES ALL ELECTRICAL TO COMPLY WITH N.E.C. AND LOCAL CODE AND REGULATIONS. 1.-SMOKE DETECTORS ARE REQUIRED IN EACH EXISTING SLEEPING ROOM AND IN THE HALLWAY AREA SERVING EACH SLEEPING ROOM BATTERY OPERATED DETECTORS ARE ACEPTABLE FOR EXISTING CONSTRUCTION. 2.-ALL BEDROOMS, FAMILYROOMS, LIVINGROOMS, DENS PARLORS, SUNROOMS, LIBRARIES, COMPUTER AND RECREATION ROOMS, AND HALLWAYS CIRCUITS (LIGHTING AND RECEPTACLES) MUST BE PROTECTED BY ARC FAULT CIRCUIT INTERRUPTER (A.F.C.I.). COMBINATION TYPE... KITCHEN, BATHROOMS AND BASEMENTS ARE EXEMPT FROM THIS REQUIREMEN. 3.-PROVIDE FLOURESCENT LIGHTING IN BATHROOMS AND KITCHENS. 4.-SMOKE DETECTORS TO BE POWERED BY 110V AND HARDWIRED WITH A BATTERY BACKUP AND SIMULTANEOUS ALARM.CONNECTED TO ALL SMOKE DETECTORS. CARBON MONOXIDE DETECTORS SHALL BE INTERCONECTED SUCH THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS. 5.-ELECTRICAL FIXTURES INSTALLED ABOVE TUBS AND SHOWERS TO BE WATERPROOF. 6.-ALL 125V SINGLE PHASE,15 AND 20 AMPHERE RECEPTACLES INSTALLED IN THE FOLLOWING LOCATIONS SHALL HAVE GROUND FAULT CIRCUIT INTERRUPTER PROTECTION: ALL RECEPTACLES LOCATED IN BATHROOMS, GARAGES,OUTDOORS SERVING COUNTERTOP IN KITCHENS AND IN WET BARS WITHIN 6' OF A SINK. 7.-DUPLEX RECEPTACLES SHALL BE INSTALLED IN ALL LIVING AND SLEEPING ROOMS SO THAT NO POINT ALONG ANY LENGHT OF WALL 2'-0" OR GREATER IS MORE THAN 6-0" FROM ANY OUTLET IN THAT SPACE. 8.-DUPLEX RECEPTACLES SHALL BE INSTALLED IN KITCHENS AT EACH COUNTER SPACE 12" OR WIDER, AND SO THAT NO POINT ALONG ANY LENGHT OF COUNTER IS MORE THAN 4'-0" FROM ANY OUTLET. 9.-ONE DUPLEX GFI RECEPTACLE SHALL BE PROVIDED FOR EACH LAVATORY IN BATHROOMS. BATHROOM RECEPTACLE OUTLETS SHALL BE ALL BEDROOMS, FAMILYROOMS, LIVINGROOMS, DENS PARLORS, SUNROOMS, LIBRARIES, COMPUTER AND RECREATION ROOMS, AND HALLWAYS CIRCUITS (LIGHTING AND RECEPTACLES) MUST BE PROTECTED BY ARC FAULT CIRCUIT INTERRUPTER (A.F.C.I.). COMBINATION TYPE... KITCHEN, BATHROOMS AND BASEMENTS ARE EXEMPT FROM THIS REQUIREMEN. [CEC210.12(B)] GLAZING NOTE: GLAZING IN SWINGING, AND SLIDING DOORS 9 SQUARE FEET OR LESS SHALL BE A MINIMUM CATEGORY CLASSIFICATION OF I (CPSC 16 CFR 1201) AND II WHEN MORE THAN 9 SQUARE FEET OF SLIDING (CPSC 16 CFR 1201) .... [TABLE R308.3.1(1), R308.3(1)] ESCAPE WINDOW NOTE: IN EVERY SLEEPING ROOM AND BASEMENT, PROVIODE ONE OPENABLE ESCAPE WINDOW MEETING ALL OF THE FOLLOWING: A. AN OPENABLE AREA OF NOT LESS THAN 5.7 SQUARE FEET; B. A MINIMUM 24 INCH CLEAR OPENABLE HEIGHT; C. A MINUMUM CLEAR OPENABLE WIDTH OF 20 INCHES; D. A SILL HEIGHT NOT OVER 44 INCHES ABOVE THE FLOOR. NOTE: 20" X 24" DOES NOT EQUAL 5.7 SQUARE FEET REFER TO THE 0f OPENABLE ILLUSTRATION FOR MINIMUM w AREA DIMENTIONS REQUIRED FOR 0 OPENABLE AREA. 5.7 SQ. FT. N MINIMUM OPENABLE NET CLEAR AREA 24" OPENING 5.7 SQ. FT. CLEAR MINIMUM MIN. I 20" NET d I 34" CLEAR .I F CL R F MINIMUM OPENABLE _ C7 WIDTH w xQ _2 J J_ V FLOOR LEVEL WINDOW EGRESS DETAIL SUPPLIED BY AT LEAST ONE 20AMP BRANCH DOOR EGRESS NOTE CIRCUIT, SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. NOT LESS THAN ONE EGRESS DOOR SHALL BE PROVIDED 10.-ONE DUPLEX GFI RECEPTACLE EACH SHALL BE PROVIDED AT. -FRONT OF DWELLING,REAR OF FOR EACH DWELLING UNIT. THE EGRESS DOOR SHALL BE DWELLING AND IN GARAGE. SIDE -HINGED, AND SHALL PROVIDE A CLEAR WIDTH OF NOT 11.-HALLWAYS EXCEEDING 10'-0" IN LENGHT SHALL BE PROVIDED WITH MIN. OF ONE DUPLEX LESS THAN 32 INCHES WHERE MEASURED BEETWEEN THE RECEPTACLE. FACE OF THE DOOR AND THE STOP, WITH THE DOOR OPEN 12.-PROVIDE POWER AND SWITCHED LIGHT FIXTURE IN ATTIC ADJACENT TO ACCESS PANEL. 90 DEGRES. THE CLEAR HEIGHT OF THE DOOR OPENING 13.-ELECTRICAL CONTRACTOR TO SPECIFY SHALL BE NOT LESS THAN 78 INCHES IN HEIGHT MEASURED GROUNDING ELECTRODE SYSTEM BOND TO GAS AND WATER PIPING. FROM THE TOP OF THE THRESHOLD TO THE BOTTOM OF THE 14.-"ALL ELECTRICAL OUTLETS SHALL BE STOP. OTHER DOORS SHALL NOT BE REQUIRED TO COMPLY LISTED TAMPER RESISTANT RECEPTACLES" (CEC 406.4 D.5) WITH THESE MINIMUM DIMENSIONS. EGRESS DOORS SHALL INSTALLED BE READILY OPENABLE FROM INSIDE THE DWELLING WITOUT IN ORKMANTSHALLBE IN A NEAT AND WORKMANLIKE MANNER" (CEC 2022 SECTION 110.12) THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. 16.-"ALL LIGHTS SHALL BE DESIGNED AND LOCATED SO THAT DIRECT RAYS ARE CONFINED TO THE SMOKE DETECTORS PROPERTY" PROVIDE SMOKE DETECTORS IN THE AREAS LEADING TO BEDROOMS.WHEN MORE THAN ONE SMOKE ALARM IS PLUMBING NOTES REQUIRED TO BE INSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT THE ALARM DEVICES SHALL BE ALL PLUMBING TO COMPLY WITH LOCAL CODE AND REGULATIONS. INTERCONNECTED IN SUCH A MANNER THAT THE 1.-ALL WATER CLOSETS IN THIS BUILDING TO BE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE STATE OF CALIFORNIA DEPARTMENT OF HOUSING AND MAXIMUM 1.28 GALLONS PER FLUSH. ALARMS IN THE INDIVIDUAL UNIT. 2.-CONTROL VALVES FOR SHOWER AND TUB/SHOWER SMOKE DETECTORS TO BE POWERED BY 110V AND SHALL BE THE PRESSURE BALANCE OT THERMOSTATIC MIXING VALVE TYPE. HARDWIRED WITH A BATTERY BACKUP AND SIMULTANEOUS 3.-PROVIDE P&T RELEIF VALVE AT WATER HEATER. ALARM. CONNECTED TO ALL SMOKE DETECTORS. 4.-PROVIDE BACKFLOW PREVENTER AT ALL HOSE BIBBS. WILL BE INSTALLED AND MAINTAINED ACCORDING TO 5.-MECHANICAL VENTILATION, WHERE OCCURS AT MANUFACTER'S INSTRUCTIONS. TOILET COMPARTMENTS, BATHROOMS AND LAUNDRY ROOMS SHALL BE CAPABLE OF PROVIDING 5AIR SMOKE ALARMS SHALL BE LISTED AND LABELED IN ACCORDANCE CHANGES PER HOUR MIN. WITH UL 217. SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING AND SHALL BE EQUIPPED WITH A BATTERY BATHROOM WALL COVERING NOTE RA(;Kl IP WALL COVERING TO BE CEMENT PLASTER, TILE OR APPROVED EQUAL TO 72" ABOVE DRAIN AT SHOWER OR TUB WITH SHOWERS. MATERIALS OTHER THAN STRUCTURAL ELEMENTS SHALL BE MOISTURE RESISTANT.GLASS ENCLOSURE DOORS AND PANELS MUST BE LABELED CATEGORY 11.SWING DOOR OUTWARD. NET AREA OF SHOWER RECEPTOR SHALL BE NOT LESS THAN 1,024 SQ. IN. OF FLOOR AREA, AND ENCOMPASS 30" DIAMETER CIRCLE. LANDING NOTE: A LANDING WITH A WIDTH NOT LESS THAN THE WIDTH OF THE DOOR AND LENGTH IN THE DIRECTION OF TRAVEL OF NOT LESS THAN 36 INCHES,WILL BE PROVIDED ON EACH SIDE OF DOORS.THE ELEVATION OF LANDING SHALL NOT EXCEED 1 1/2 INCH DIFFERENCE THAN THE THRESHOLD OF THE DOORWAY (7 3/4 INCH IF DOOR DOES NOT SWING OVER THE LANDING OR STEPS) IN EACH DIRECTION. [CRC R311.3.11 LUMINARIES GENERAL NOTES: 1.-PERMANENTLY INSTALLED LUMINARIES IN: 2.-KITCHENS SHALL HIGH EFFICACY LUMINARIES WITH SEPARATED CIRCUIT. 3.-BATH ROOMS, GARAGES, LAUNDRY ROOMS AND UTILITY ROOMS SHALL BE HIGH EFFICACY LUMINARIES, AND CONTROLLED BY AN OCCUPANT SENSOR. 4.-OTHER THAN IN KITCHENS,BATHROOMS,GARAGES, LAUNDRY ROOMS AND UTILITY ROOMS SHALL BE HIGH EFFICACY LUMINARIES,OR CONTROLLED BY DIMMER SWITCH, AND CONTROLLED BY AN OCCUPANT SENSOR. 5.-OUTDOOR LIGHTING MOUNTED TO THE BUILDING SHALL BE HIGH EFFICACY AND CONTROLLED BY A PHOTO CONTROL/MOTION SENSOR. CARBON MONOXIDE PROVIDE CARBON MONOXIDE SENSORS IN THE AREAS LEADING TO BEDROOMS. WHEN MORE THAN ONE CARBON MONOXIDE ALARM IS REQUIRED TO BE INSTALLED WITHIN THE DWELLING UNIT OR SLEEPING UNIT THE ALARM SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM SHALL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. PROVIDE CARBON MONOXIDE ALARMS IN DWELLING UNITS AND IN SLEEPING UNITS WITHIN WHICH BURNING APPLIANCES ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES. SHALL BE INSTALLED OUTSIDE EACH SLEEPING AREA, ON EVERY LEVEL OF A DWELLING UNIT. CARBON MONOXIDE ALARMS SHALL COMPLY WITH SPECIFIC LOCATION REQUIREMENTS PER NFPA 72 SECTION 29.8.3.4 CARBON MONOXIDE ALARMS PROVIDED SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 2034. CARBON MONOXIDE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING AND SHALL BE EQUIPPED WITH A BATTERY BACK UP. CARBON MONOXIDE ALARMS SHALL BE INTERCONNECTED SO THAT ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS WITHIN THE DWELLING UNIT. ROOM NAME MANDATORY LIGHTING MEASURES KITCHEN HIGH EFFICACY AND MANUAL -ON OCCUPANCY SENSOR OR DIMMER BATHROOM, GARAGE, HIGH EFFICACY LAUNDRY ROOM AND UTILITY ROOM MANUAL -ON OCCUPANCY OR VACANT SENSOR ALL OTHER INTERIOR HIGH EFFICACY ROOMS (E.G., LIVING AND ROOM, DINING ROOM, MANUAL -ON OCCUPANCY SENSOR BEDROOMS, HALLWAYS) OR EXCEPT CLOSET AND HALLWAYS LESS DIVER THAN 70 SQ. FT. OUTDOOR LIGHTING HIGH EFFICACY ATTACHED TO BUILDINGS AND MANUAL -ON OCCUPANCY SENSOR > PHOTOCONTROL ELECTRIC LEGEND SINGLE POLE SWITCH & 110V DUPLEX OUTLET SMOKE DETECTOR HARD WIRE W/BATTERY BACKUP LIGHT FIXTURE HIGH EFFICACY ll /I I�GFI 11 OV DUPLEX OUTLET GFI VACANCY SENSOR LIGHT OR OCCUPANCY SENSOR S VACANCY SENSOR SWITCH S MOTION SENSOR CONTROL O CARBON MONOXIDE co ALARM ® EXHAUST FAN EXHAUST VENT TO BE: NUTONE 50 to 80 CFM MODEL 744 RNL CEILING MOUNT BATH FAN WITH 3 INCHES DUCT FLEXIBLE PIPE DIRECTED TO OUTSIDE THROUGH ROOF (MAX 70 FEET WITHOUT ELBOWS PER ASHRA STANDARD 62.2 TABLE 7.1) WITH A MAXIMUM SOUND RATING OR 2 SONE FOR INTERMITTENT OPERATION. �`L �� /I IVIGFI BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE IS MORE THAN 24 INCHES. [CEC 210.52(C)(1)] VACANCY SENSOR LUMINAIRE NOTE IN BATHROOMS, GARAGES, LAUNDRY ROOMS, PANTRIES AND UTILITY/STORAGE ROOMS, AT LEAST ONE LUMINAIRE SHALL BE CONTROLLED BY AN OCCUPANT OR VACANCY SENSOR. LUMINARIES FOR CLOSETS MORE THAN 70 SQ. FT. SHALL BE CONTROLLED WITH DIMMERS OR VACANCY SENSOR. co DRYER VENTS DUCT NOTE DUCTS FOR DRYER VENTS SHALL BE A MINIMUM OF 4" IN DIAMETER. THE EXHAUST DUCT SHALL NOT EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGHT OF 14 FEET, INCLUDING TWO 90-DEGREE ELBOWS. TWO FEET SHALL BE DEDUCTED FOR EACH 90-DEGREE ELBOW IN EXCESS OF TWO. ALL OUTLETS FOR DWELLINGS, OTHER THAN THOSE COVERED IN 210.8 (A) (3), EXCEPTION TO (3), THAT ARE SUPPLIED BY SINGLE-PHASE BRANCH CIRCUITS RATED 150 VOLTS TO GROUND OR LESS, 50 AMPERES OR LESS, SHALL HAVE GROUND -FAULT CIRCUIT -INTERRUPTER PROTECTION FOR PERSONNEL. Z JV 5} =Zx N (E) HUNG VINYL 2'-6" x 4'-6" CLOSET 141 4'-0" J } Z > cnc _ wU)` o ILLX A I oW T_ ? Ilk 19 nJN _}x - Z, n >o LU < 10'-8'/2" SYMBOL SIZE DESCRIPTION MATERIAL U-FACTOR SHGC E4'0 "X 4'0" DBL PANE HUNG VINYL 0.28 0.22 WINDOW �1 2'8"X 6'8" HOLLOW INTERIOR WOOD DOOR 2 2'6"X 6'8" HOLLOW INTERIOR WOOD DOOR E3'0"X 6'8" CLOSET WOOD DOOR F J 4'0"X 6'8" CLOSET WOOD DOOR (E) HUNG (E) HUNG VINYL VINYL 2'-0" x 3'-0" 2'-0" x 3'-0" 0 0 (E) KITCHEN NEW BEDROOM 35'-3" 33'-911 1'-611 DRYER DUCT O 4- M (N) O� ZW 1= Uj SL)O wU (E) WALL (E) DINING AREA o \ CV 00 o \ 10'-5 9/16" C CV ' 6'-0" OPENING L (E) LIVING ROOM. V-0" x 4'-6" 4'-6" x 4'-6" 1'4" 4'-6" V-0" x 4'-6" (E) HUNG (E) FIXED (E) UNG (E) HUNG VINYL VINYL VI YL VINYL (E) PORCH 33'-9" 0 LO 4TER HEA 3'-0" x 4'-6" (E) BEDROOM #2 24"x30" CLEAR SPACE IN FRONT OF THE TOILET. THE SINK CANNOT ENCROACH INTO THE CLEAR SPACE, 2'-8" 2'-6" shower pO4'-6" V 00 (N) BAT (p HALLWAY 24"� II N ATT 6 �CESS (E) BEDROOM #1 V-0" x 4'-6" 1'-0" A 4'-6" 4'-6" x 4'-6" V-0" x 4'-6" (E) HUNG (E) H NG (E) FIXED (E) HUNG VINYL VI YL VINYL VINYL co of "toJ X_ -IZ o�> Mw a zo (7 Z xZ Z oW > �0_ 1'-6 r LO rel FOR PERMIT ISSUANCE Mas er ID: Dat E 0 O 0 0 ru Ln Ln 0 E Ev *, AN qm ID c? 0 v N u � > v N N O Am 0) 2- O V J O UJ��^N VJ wz(n u z00< Z O O �!�/^� V) < uj mCOZ v , Z L.I. O O J LL• W Z D RAW N O.M. CHECKED DATE 02-27-2025 SCALE AS NOTED JOB NO. 2507 SHEET NO. A-3