Loading...
HomeMy WebLinkAbout740 W St Andrew Pl & 2002 S Parton St - PlanWEST ST. ANDREW PL SO U T H P A R T O N S T . 5' - 0 " 9' - 0 " PL PL 22 ' - 1 1 " 6' W I D E U T I L I T Y E A S E M E N T PL (E) HOUSE (E) PORCH PATH OF TRAVEL PL 36 ' - 0 " 37'-6" 34'-6" 6'-0"5'-0" 12 ' - 6 " OPEN SPACE: 1,347 SQ FT PATH OF TRAVEL(E) CONCRETE PA T H O F T R A V E L (E) CONCRETE (E) CONCRETE (E) CONCRETE (E) SIDEWALK (E) SIDEWALK (E ) S I D E W A L K (E ) S I D E W A L K (E ) L A N D S C A P E (E ) L A N D S C A P E (E) LANDSCAPE (E) LANDSCAPE 25'-7" 50 ' - 0 " 125'-0" 32 ' - 6 " 21 ' - 1 0 " 23'-0" 5'-0" (E) GARAGE = 441 SQ.FT = 59 SQ.FT (N) ADDITION + 1202 SQ.FT 125 SQ.FT 14'-5" (E)PATIO COVER UN-PERMITTED 503.8 SQ.FT PATIO TO BE DEMOLISHED (N) BALCONY 78 SQ.FT 5' - 4 " 3' - 4 " 4' - 4 " 2' - 0 " 2'-0" EXISTING GARAGE PROPOSED ADDITION A PROJECT FOR: PROJECT ADDRESS: SHEET TITLE DATE: SHEET: PROJECT INFO PROJECT # DRAWN BY: CHECKED BY: SCALE: AS SHOWN AT T A C H E D A C C E S S O R Y DW E L L I N G U N I T 74 0 W S t . A N D R E W S P L A C E SA N T A A N A CA 9 2 7 0 7 - 2 6 2 1 REVISED BY: REVISIONS: DATE:BY: PROJECT: REVISED BY: DESIGNER: YMMAR BROWN ENGINEER: VISAL TE PROJECT INFORMATION OCCUPANCY GROUP: CONSTRUCTION TYPE:VB SPRINKLERED: PLAN SHEET LIST SITE PLAN / PROJECT INFO VICINTY MAP SITE PLAN SCALE: 1/8" = 1'-0" NO 740 W St. ANDREWS PLACE, SANTA ANA, CA 92707-2621 ATTACHED ACCESSORY DWELLING UNIT A-1 R3 NUMBER OF STORIES: 2- STORY 1 OF 5 SITE PLAN A-1 FLOOR PLAN AND DEMO PLANA-2 SECTIONS AND ELECTRICAL PLAN A-4 T-1 T-2 T-3 G GREEN NOTES TITLE-24 REPORT TITLE-24 REPORT TITLE-24 REPORT ELEVATION PLAN AND ROOF PLANA-3 ADDRESS: LEGAL DESCRIPTION & SCOPE OF WORK APN: TRACT NO: LAND DESCRIPTION: ZONING: SCOPE OF WORK: LOT AREA: 6,250 SF COVER: (E) 1202 SF + (E) 441 SF + (E) 125 SF +(N) 59 SF +(N) 500 SF + (N) 78 SF = 2,327 SF N TR 289 BLK L LOT 1 HOUSE 2022 CALIFORNIA BUILDING CODE (TITLE 26) 2022 CALIFORNIA ELECTRICAL CODE (TITLE 27) 2022 CALIFORNIA PLUMBING CODE (TITLE 28) 2022 CALIFORNIA MECHANICAL CODE (TITLE 29) 2022 CALIFORNIA RESIDENTIAL CODE (TITLE 30) 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (TITLE 31) CODE COMPLIANCE: MAX. ALLOW F.A.R = 35% OR 2187.5 SF > 1,905 SF CONSULTANT LIST OWNER: DESIGN FIRM: AHAE DESIGN INC. 833 VICTOR AVE, INGLEWOOD, CA 90031 SEANALEWIS@AHAEDESIGNSNC.COM Tel:323-302-2657 or 626-800-7764 2002 S PARTON ST. SANTA ANNA, CA 92707-2621 GARAGE 2002 S PARTON ST. SANTA ANNA, CA 92707-2621 40837309 R-1 74200 BUS STOP MAP HUMBERTO GARCIA, MARIA GARCIA ROBEN MARDIROSIAN (PE) ARMENCONSULTING ENGINEERS 10540 JARDINE AVE. SUNLAND, CA 91040 TEL: 818-484-0495 ROBEN@ARMENGINEERS.COM CONVERT (E) DETACHED 441 SQ.FT GARAGE W/ 59 SQ.FT ADDITION TO FIRST FLOOR + 500 SQ.FT 2ND STORY ADDITION TO NEW DETACHED ADU. ADU WILL CONSIST OF 2 STORIES, (2) BED, (2.5) BATH, (1) KITCHEN, AND (1) LIVING ROOM. NEW 78 SQ.FT SECOND LEVEL BALCONY. NEW PATIO/LOGGIA. ATTACHED UNPERMITTED 503.8 SQ.FT PATIO TO BE DEMOLISHED. LAND USE:RESIDENTIAL (SINGLE FAMILY RESIDENTIAL) LOT NUMBER:1 ENERGY CONSULTANT: OPEN SPACE GARAGE/ACCESSORY STRUCTURE CONVERSION TO ADU NOTES: 1.INSPECTOR TO VERIFY EXISTING CONTINUOUS FOOTINGS UNDER EXTERIOR WALLS EXTEND A MINIMUM OF 12" BELOW GRADE AND VERIFY EXISTING WOOD SILL PLATE IS LOCATED A MINIMUM OF 8 INCHES ABOVE ADJACENT GRADE. 2.THE OWNER ACKNOWLEDGES POSSIBLE UPGRADES ARE REQUIRED IF THERE IS SUBSTANTIAL DAMAGE TO THE GARAGE STRUCTURE/FOUNDATION. 3.APPLICATION OF AN APPROVED VAPOR RETARDER EQUIVALENT PRODUCT (ICC ESR Nos. 1413, 2417, 2785, OR 3474) FOR USE ON EXISTING SLABS IS REQUIRED. ANY ALTERNATIVE COMPLIANCE FOR MATERIALS AND/OR METHODS REQUIRES SEPARATE APPROVAL FROM THE LOS ANGELES COUNTY BUILDING AND SAFETY RESEARCH SECTION. NOTES ON PLAN: 1.THE ADU SF/ SFD SF RATIO IS FOR PARK AND REC FEE PURPOSE ONLY. THE APPLICANT IS RESPONSIBLE FOR THE GIVEN "SFR SF" OF THE EXISTING PRIMARY RESIDENCE; BUILDING AND SAFETY STAFF ARE NOT RESPONSIBLE FOR THE ACCURACY OF THE GIVEN "SFR SF" OF THE EXISTING RESIDENCE. RATIO OF ADU SQ/ SFR SQ = 999 1202 = .83 ADDITION PORCH 1ST FLOOR ADU 2ND FLOOR ADU ADDITION EXISTING MAIN HOUSE PLAN & PERSPECTIVEA-5 2ND FLOOR BALCONY G-1 GREEN NOTES G-2 GREEN NOTES SN1 GENERAL NOTES S0.1 TYPICAL DETAILS S0.2 TYPICAL DETAILS S0.3 TYPICAL DETAILS S1.0 FOUNDATION, 2ND FLOOR, AND ROOF FRAMING PLAN S2.0 STRUCTURAL DETAILS S2.1 STRUCTURAL DETAILS S3.0 STRUCTURAL DETAILS T-4 TITLE-24 REPORT 10/16/2024 YB HERS FEATURE SUMMARY (SEE TITLE-24): -INDOOR AIR QUALITY VENTILATION -KITCHEN RANGE HOOD -VERIFIED EER/EER2 -VERIFIED SEER/SEERS2 -VERIFIED REFRIGERANT CHARGE -AIRFLOW IN HABITABLE ROOMS (SC3.1.4.1.7) -VERIFIED HSPF2 -VERIFIED HEAT PUMP RATED HEATING CAPACITY -WALL MOUNTED THERMOSTAT IN ZONES GREATER THAN 150 SQ.FT (SC3.4.5) -DUCTLESS INDOOR UNITS LOCATED ENTIRELY IN CONTROLLED SPACE (SC3.1.4.1.8) -PIPE INSULATION, ALL LINES SPECIAL FEATURES REQUIRED: (SEE TITLE-24): -COOL ROOF -VARIABLE CAPACITY HEAT PUMP COMPLIANCE NEW ADU IS 962 SQ.FT (FIRST FLOOR IS 462 SQ.FT, SECOND FLOOR IS 500 SQ.FT). DESIGNER: YMMAR BROWN ENGINEER: VISAL TE Bldg #101122260 APPROVALS: PLNG - C. Santana BLDG - K. Ahangian POLICE - B. Martin PUBLIC WORKS- B. Sarlak ROOF SLOPE ±2:12 ROOF SLOPE ±2:12 ROOF SLOPE ±2:12 ROOF SLOPE ±2:12 ROOF SLOPE ±2:12 ROOF SLOPE ±2:12 RO O F SL O P E 2% M I N W/D SHOWER T.V. DINNING 2161 sq.in 372.7 sq.ft 12.4 sq.ft 23'-0" 21 ' - 9 " 18 ' - 4 " 3 STACKED OVEN 5 1 6 6 2 3 4 4 7 1 2 3 4 5 6 7 8 9 10 5' - 3 " 6' - 1 1 " 1' - 3 " 2' - 6 " 3' - 2 " 3'-0" 6'-0" 3' - 0 " LANDING 8 11 TEMP. GLAZING 2' - 0 " 2'-0" 60" TUB SHOWER BEDROOM 2 120.9 SQ.FT 21 ' - 9 " 2 BEDROOM 1 172.3 SQ.FT 54.1 SQ.FT 54.1 SQ.FT BATH 23'-0" 2 4 2 2'-8" W.I.C 3 BALCONY11 3' - 4 " 3'-0" 3' - 0 " 3' - 0 " 5 6 7 8 9 10 11 12 13 15 16 17 14 5' - 3 " LANDING LANDING W.I.C 9TEMP. GLAZING TEMP. GLAZING (E) 2-CAR GARAGE DOOR COMPRSSIBLE ELEMENT THRESHOLD INTERIOR FLOOR LEVEL EXTERIOR FLOOR OR LANDING LEVEL 7 3 4" I N . M A X . 12" I N . MI N DOOR SWINGS DETAIL 1: THRESHOLD DETAIL SCALE: NTS 2X FRAMING SEE STRUCTURAL PLAN 5/8 " TYPE "X" GYPSUM BOARD AT INTERIOR PER PLAN GRADE 'D' 60 MINUTE BUILDING PAPER, (USE TWO LAYERS WHEN APPLIED OVER SOLID PANELS) RESILIENT CHANNELS PERPENDICULAR TO JOISTS AT 16 O.C. EXTERIOR STUD WALL DETAIL SCALE: NTS 3" Min. BATT INSULATION (PER PLAN) EXTERIOR CEMENT PLASTER ON CORROSION RESISTANT METAL LATH 5/8 " TYPE "X" GYPSUM BOARD AT INTERIOR PER PLAN ATTIC CALCULATIONS PROVIDE ATTIC VENTS AT A RATE OF 1 S.Q. PER 150 FT OF AREA BEING VENTILATED, IF THE VENTILATION IS ONLY BEING PROVIDED ON THE EAVES ONLY. IF AT LEAST 40 PERCENT BUT NOT MORE THAN 50 OF THE VENTILAION IS BEING PROVIDED WITH IN 3 FEET MEASURED VERTICALLY FROM THE RIDGE OR HIGHEST POINT OF THE AREA BEING VENTILATED . THE VENTILATION RAE CAN BE REDUCED TO 1S.F. FOR 300 S.F. BEING SERVED. PROVIDE RAFTER SPACE VENTILATON. (CRC R806) ATTIC AREA=0.00 S.F. VENT AREA REQUIRED 69.00 S.F/150 S.F =.5 S.F.= 72 SQ-IN VENT PROVIDED= (400.0 SQ-IN) OF DORMER USE= (2) DORMERS (453.6 SQ-IN) NOTE:DORMER N.F.V.=100 SQ-IN (N) 2'X4' SLIDING WINDOW U-0.3 SHG-0.23 DUAL GLAZE - TEMP 3 FLOOR PLAN AND DEMO PLAN A-2 WALL LEGEND DEMO WALL PROPOSED WALL NOTE: a.All emergency escape and rescue openings shall have a minimum clear opening of 5.7 square feet with a minimum net clear opening height of 24 inches and width of 20 inches (R310.2.1). b. Where a window is provided as the emergency escape and rescue opening, it shall have the bottom of the clear opening not greater than 44 inches measured from the floor (R310.2.2). c. Emergency escape and rescue openings shall be clear of any obstruction and operational from the inside of the room without the use of keys, tools or special knowledge (R310.1.1 d.NFRC window labels to be removed only by owners after final building inspection e. 13 oz. face wt. carpet (31 oz. tot) and 40 oz. jutted pad, or 48 oz. foam rubber, or 3/8" rebonded urethane foam (4 pcf), or ½" urethane foam (2.4 pcf). f. 2. Type and spacing of resilient channels and the attachment of channels and gypsum board or lath shall be as required for fire ratings. g. 3. Sheet vinyl and linoleum floor coverings with 1/8" minimum thickness resilient backing may be substituted for carpet and padding in kitchen and bathroom areas, if ceilings are on resilient channels. h. 4. The mineral fiber insulation shall have a thermal resistance R value of 11 or greater as determined by Federal Specification HH-I-521E. GLAZING NOTES: The following shall be considered specific hazardous locations requiring safety glazing per Section R308: a. Glazing in fixed and operable panels of swinging, sliding, and bifold doors. b. Glazing in fixed or operable panels adjacent to a door where the bottom exposed edge of the glazing is less than 60 inches above the walking surface and it meets either of the following conditions: 1. Where the glazing is within 24 inches of either side of the door in the plane of the door in a closed position. 2. Where the glazing is on a wall perpendicular to the plane of the door in a closed position and within 24 inches of the hinge side on an in-swinging door. c. Window glazing in an individual fixed or operable panel, that meets all of the following conditions: 1. The exposed area of an individual pane is larger than 9 square feet. 2. The bottom edge is less than 18 inches above the floor. 3. The top edge is more than 36 inches above the floor. 4. One or more walking surfaces are within 36 inches, measured horizontally and in a straight line, of the glazing. d. Glazing in guards, railings, structural baluster panels, and nonstructural in-fill panels, regardless of area or height above a walking surface. e. Glazing in walls, enclosures or fences containing or facing hot tubs, spas, whirlpools, saunas, steam rooms, bathtubs, showers, and indoor or outdoor swimming pools, where all of the following conditions are present: 1. The bottom edge of the glazing is less than 60 inches above any standing or walking surface. 2. The glazing is within 60 inches, measured horizontally and in a straight line, from the water’s edge of a hot tub, spa, whirlpool, bathtub, or swimming pool, or from the edge of a shower, sauna or steam room. f. Glazing adjacent to stairs and ramps where the bottom exposed edge is less than 36 inches above the plane of the adjacent walking surface of stairways, landings between flights of stairs, and ramps, unless the glazing is 36 inches or moremeasured horizontally from the walking surface, or a rail is designed per Section R308.4.6. g. Glazing adjacent to the landing at the bottom of a stairway where the glazing is less than 36 inches above the landing and within a 60-inch horizontal arc less than 180 degrees from the bottom treadnosing, unless the glazing is more than 18 inches from a protective guard per Section R312. WINDOW SCHEDULE DOOR SCHEDULE (N) 3' X 6'-8" exterior glass double door, U-0.3 SHG-0.23 Dual Glaze - TEMP A PROJECT FOR: PROJECT ADDRESS: SHEET TITLE DATE: SHEET: PROJECT INFO PROJECT # DRAWN BY: CHECKED BY: SCALE: AS SHOWN AT T A C H E D A C C E S S O R Y DW E L L I N G U N I T 74 0 W S t . A N D R E W S P L A C E SA N T A A N A CA 9 2 7 0 7 - 2 6 2 1 REVISED BY: REVISIONS: DATE:BY: PROJECT: REVISED BY: DESIGNER: YMMAR BROWN ENGINEER: VISAL TE (N) 5' X 6' SLIDING WINDOW U-0.3 SHG-0.23 DUAL GLAZE - TEMP (N) 3'X4' SLIDING WINDOW U-0.3 SHG-0.23 DUAL GLAZE - TEMP 2 1 2 1 1 OWNER TO PROVIDE SHOWER HEAD AND FIXTURES. PROVIDE A 24" X 30" CLEAR SPACE IN FRONT OF WATER CLOSE. DOUBLE SINK WITH GARBAGE DISPOSAL. LANDING 3'x3' (4" CONCRETE SLAB) WITH#4 REBAR WITH 18" O.C. EACH WAY. PIECE FIBERGLASS SHOWER/TUB COMBO W/ TEMPERED GLASS. SHOWER COMPARTMENT REGARDLESS OF SHAPE, SHALL HAVE A MINIMUM FINISHED INTERIOR OF 1,024 SQUARE INCHES AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH CIRCLE, THE DIMENSIONS SHALL BE MAINTAINED TO A POINT OF 70 INCHES ABOVE THE SHOWER DRAIN OUTLET WITH NO PROTRUSIONS OTHER THAN THE VALVE(S), SHOWERHEAD, SOAP DISH, SHELVES, AND SAFETY GRAB BARS, OR RAILS. (CPC 408.6) STACKED WASHER DRYER, PROVIDE METAL PAN WITH DRAIN TO DRAIN OR DAY LIGHT CONDENSER, PROVIDE A A 3' X 3'X4" CONCRETE PAD W. #4 REBAR 3 MIN. EACH WAY ASPHALT SHINGLE TIMBERLINE ESR1475 TO MATCH (E) HOME TMP STANDING METAL SEAM ROOFING PANEL ESR5046 HANDRAILS SHALL BE A MIN FOR 34" AND A MAX OR 38" ABOVE EACH FLIGHT OF STAIR MEASURE VERTICALLY FROM LINE CONNECTING EACH LEADING EDGE. SHALL BE CONTINUOUS FROM THE FIRST RISER TO THE LAST RISER. FUTURE HEAT PUMP WATER HEATER (2.5'X2.5'X7') WALL LINE TO BE DEMOLISHED. WALL LINE TO BE RETAINED. GARAGE DOOR TO BE DEMOLISHED. SEE DETAIL 1 ON SHEET A-2 DURABLE, NON-ABSORBENT FINISH MATERIAL W/ DEX-O-TREX (ESR-1757) UNDERSIDE OF EAVE OVERHANG SHALL BE 1-HR FIRE RATED PER DETAIL 1 ON SHEET A-3. SEE DETAIL-3 ON SHEET A-3. (MINIMUM 1 HANDRAIL ON ONE SIDE REQUIRED). 3 5 2 6 7 8 NOTE LEGEND 10 4 9 ALL PLUMBING FIXTURES SHALL COMPLY TO SENATE BILL 407 WATER LINE OF TYPE "L" COPPER WATER CONSERVING PLUMBING FIXTURES & FITTINGS AS DEFINED BY 2019 CALIFORNIA BUILDING CODE (SECTION 4.303) ARE: 1.28 GALL/FLUSH TOILET 2.0 GALLON/MINUTE SINGLE SHOWER HEAD AT 80 PSI* 1.2 GALLON /MINUTE LAVATORY FAUCETS AT 60 PSI 1.8 GALLON/MINUTE KITCHEN FAUCETS AT 60 PSI PLUMBING REQUIREMENTS WHERE STATIC PRESSURE IN THE WATER SUPPLY PIPING IS EXCEEDING 80 PSI AN APPROVED PRESSURE REGULATOR PROCEEDED BY AN ADEQUATE STRAINER SHALL BE INSTALLED. (CPC SEC 608.2) GENERAL PROVIDE WATER SYSTEM WITH A PRESSURE REGULATOR, CHECK VALVE, BACKFLOW PREVENTER OR OTHER NORMALLY CLOSED DEVICE THAT PREVENTS DISSIPATION OF BUILDING PRESSURE BACK INTO THE WATER MAIN, WITH AN EXPANSION TANK. CPC SEC. 608.2 & 608.3 THE DISCHARGE PIPING SERVING A TEMPERATURE RELIEF VALVE, PRESSURE RELIEF OR COMBINATION OF BOTH SHALL BE PROVIDED WITH A DRAIN, NOT SMALLER THAN THE RELIEF VALVE OUTLET, SHALL DISCHARGE INDEPENDENTLY BY GRAVITY THROUGH AN AIR GAP INTO THE DRAINAGE SYSTEM OR EXTEND OUTSIDE THE BUILDING WITH THE END OF THE PIPE NOT MORE THAN 2’ FEET NOR LESS THAN 6” INCHES ABOVEGROUND AND POINTING DOWNWARD AND DISCHARGE IN A MANNER THAT DOES NOT CAUSE PERSONAL INJURY (CPC SEC. 608.5) 30" CLR 24" CLR 15" 15" 24" SCALE: 1/4" = 1'-0" ROOF PLAN (N) 4'X6'8" SLIDING WINDOW U-0.3 SHG-0.23 DUAL GLAZE - TEMP 4 (N) 32" X 6'-8" hollow core interior pocket door3 SCALE: 1/4" = 1'-0" (N) 2ND FLOOR PLAN SCALE: 1/4" = 1'-0" (N) 1ST FLOOR PLAN (N) 3'X5' SLIDING WINDOW U-0.3 SHG-0.23 DUAL GLAZE - TEMP 5 5 2 2 3 4 4 5 5 6 7 12 8 SCALE: 1/4" = 1'-0" (E) FLOOR/DEMO PLAN 6 (N) 3'0"X8' FIXED WINDOW U-0.3 SHG-0.23 DUAL GLAZE - TEMP 4 (N) 8'X8' FIXED DOOR U-0.3 SHG-0.23 DUAL GLAZE - TEMP A-A A-4 A-A A-4 9 B- B A- 4 B- B A- 4 10/16/2024 YB 7 (N) 1'6"X5' FIXED WINDOW U-0.3 SHG-0.23 DUAL GLAZE - TEMP (N) 3' X 6'-8" exterior glass single door, U-0.3 SHG-0.23 Dual Glaze - TEMP (N) 2'0"X5' FIXED WINDOW U-0.3 SHG-0.23 DUAL GLAZE - TEMP (N) 2'6"X2' FIXED WINDOW U-0.3 SHG-0.23 DUAL GLAZE - TEMP 8 9 EXISTING WALL FIRST FLOOR ADDITION AREA 1 11 11 11 12 13 12 12 13 14 13 14 15 15 15 SEE SHEET A-4 FOR ALL ELECTRICAL REQUIREMENTS/NOTES-CALLOUTS. 16 16 17 17 17 18 18 18 9' - 8 " 19 ' - 1 1 " 7' - 0 " 3' - 6 " 10 " 9' - 8 " 10 " 2'-2" 3' - 4 " 9' - 8 " 19 ' - 1 1 " 7' - 1 0 " 10 " 7" 9' - 8 " 7"3' - 6 " 3' - 6 " 2'-6" 7' - 0 " 3'-4" 3' - 6 " 7' - 0 " 1'-6" 4" 3'-4" 3' - 6 " 7' - 0 " 3' - 0 " 4" ROOF PLY (SEE STRUCTURAL PLAN) ASPHALT SHINGLE (CLASS A) TIMBERLINE ESR1475 TO MATCH (E) HOME STRUCTURAL SHEATHING AS REQUIRED SEE STRUCTURAL PLAN 5/8" TYPE "X" GYPSUM WALLBOARD 2X FRAMING SEE STRUCTURAL PLAN 5/8 " TYPE "X" GYPSUM SHEATHING SIDING - TO MATCH EXISTING HOUSE. GRADE 'D' 60 MINUTE BUILDING PAPER, (USE TWO LAYERS WHEN APPLIED OVER SOLID PANELS) 7/8 " STUCCO ON UNDERSIDE FASCIA BOARD 2 X BLOCKING 2X RJ PER STRUCTURAL PLAN 2X BLOCKING PER STRUCTURE PLAN DETAIL 1: 1-HR FIRE RATED PROTECTED ROOF EAVE SCALE: NTS 1 2 3 4 5 6 7 8 9 10 11 12 13 15 16 17 14 34" TO 38" SEE DETAIL 3 SECOND LEVEL FLOOR OP E N S P A C E 1. WOOD RAIL WITH EASED EDGES 2.INTERIOR WALL FINISH 3. 3X SOLID BACKING FOR SUPPORT 4. METAL SUPPORT BRACKETS 5. 1/4" THICK STEEL PLATE W/ (2) 1/4" DIA 'SDS' SCREWS (2" MIN. PENETRATION INTO BLOCKING/ STUD HANDRAILS SHALL BE CONTINUOUS THE FULL LENGTH OF THE STAIRS PER C.B.C 1003.3.3.6 AND SHALL BE CAPABLE OF WITHSTANDING A LOAD OF AT LEASE 200 LB. APPLIED IN ANY DIRECTION AT ANY POINT ON THE RAIL PER C.B.C. TABLE 16-B. GUARDRAILS SHALL RESIST A 50LB. PER LINEAR FOOT HORIZONTAL & 200LB POINT LOAD FORCE APPLIED AT RIGHT ANGLE TO TOP RAIL PER C.B.C. TABLE 16-B HANDRAIL/ GUARDRAIL DETAIL 1 1/2" 1 1/4" 1 5 2 3 4 2" M A X . 36 " A B O V E T H E N O S E O F E A C H R I S E R RISER NOSE ELEVATION PLAN A-3 A PROJECT FOR: PROJECT ADDRESS: SHEET TITLE DATE: SHEET: PROJECT INFO PROJECT # DRAWN BY: CHECKED BY: SCALE: AS SHOWN AT T A C H E D A C C E S S O R Y DW E L L I N G U N I T 74 0 W S t . A N D R E W S P L A C E SA N T A A N A CA 9 2 7 0 7 - 2 6 2 1 REVISED BY: REVISIONS: DATE:BY: PROJECT: REVISED BY: DESIGNER: YMMAR BROWN ENGINEER: VISAL TE 1 NEW WINDOW SEE FLOOR PLAN. 7 8" STUCCO (MATCH STUCCO FINISH TO MAIN HOUSE) NEW DOOR SEE FLOOR PLAN. NEW WALL MOUNTED LIGHT SEE FLOOR PLAN. 100 AMP SUB PANEL GAF TIMBERLINE ESR #1475 2x FASCIA CONDENSER, PROVIDE A A 3' X 3'X4" CONCRETE PAD W. #4 REBAR 3 MIN. EACH WAY MINI-SPLIT UNIT TANKLESS WALL MOUNTED WATER HEATER 3 4 2 6 NOTE LEGEND 7 8 SCALE: 1/4" = 1'-0" (N) NORTH VIEW AND SECTION SCALE: 1/4" = 1'-0" (N) WEST VIEW 5 10/16/2024 SCALE: 1/4" = 1'-0" (N) SOUTH VIEW SCALE: 1/4" = 1'-0" (N) EAST VIEW 2 2 2 2 1 1 1 1 1 1 1 3 3 3 4 4 8 9 5 10 9 10 6 6 11 WOOD PANEL SIDING 11 11 12 LOGGIA 13 12 13 YB 13 TMP STANDING METAL SEAM ROOFING PANEL ESR5046 13 14 14 SEE DETAIL 1 ON SHEET A-3 15 RESERVED FOR FUTURE 7' TALL HEAT PUMP. 15 16 SEE DETAIL 2 ON SHEET A-3 16 16 16 16 1616 16 SCALE: 1/4" = 1'-0" STAIRCASE LAYOUT LANDING 3'X3' LANDING 3'X3' 17 STAIRCASE LAYOUT PROFILE STAIRCASE LAYOUT 10 14 DETAIL 3: HAND RAIL ATTACHMENT DETAIL 17 SEE DETAIL 3 ON SHEET A-3 17 DETAIL 2: GUARDRAIL DETAIL SCALE: NTS OPENINGS SHALL NOT ALLOW THE PASSAGE OF A 4" DIAMETER SPHERE. SEE STRUCTURAL PLAN FOR ALL CONNECTION DETAILS W/D SHOWER T.V. DINNING 2161 sq.in 372.7 sq.ft 12.4 sq.ft 23'-0" 21 ' - 9 " 18 ' - 4 " 3 STACKED OVEN 5 1 6 6 2 3 4 4 7 1 2 3 4 5 6 7 8 9 10 5' - 3 " 6' - 1 1 " 1' - 3 " 2' - 6 " 3' - 2 " 3'-0" 6'-0" 3' - 0 " 5'-0" LANDING 8 11 TEMP. GLAZING 2' - 0 " 2'-0" 60" TUB SHOWER BEDROOM 2 120.9 SQ.FT 21 ' - 9 " 2 BEDROOM 1 172.3 SQ.FT 54.1 SQ.FT 54.1 SQ.FT BATH 23'-0" 2 4 2 2'-8" W.I.C 3 BALCONY11 3' - 4 " 3'-0" 3' - 0 " 3' - 0 " 5 6 7 8 9 10 11 12 13 15 16 17 14 5' - 3 " LANDING LANDING W.I.C 9TEMP. GLAZING TEMP. GLAZING 9' - 8 " 19 ' - 1 1 " 7' - 0 " 10 " 19 ' - 1 1 " 9' - 8 " 3'-0" 6' - 9 " 7' - 0 " DOOR SINK SHOWER 7' - 0 " 7' - 0 " 2'-6"3'-2" 7' - 6 " 8' - 0 " 6' - 8 " 42 " ( M i n . ) FASCIA BOARD 2 X BLOCKING/ NAILER AIR-IMPERMEABLE INSULATION MUST BE R-15+R-9 INSULATION ROOF UNDERLAYMENT ASPHALT SHINGLE (CLASS A) TIMBERLINE ESR1475 TO MATCH (E) HOME UNVENTED ROOF INSULATION DETAIL SCALE: NTS 2X RJ P E R S T R U C T U R E P L A N 2X S T U D W A L L , S E E ST R U C T U R E P L A N AIR IMPERMEABLE INSULATION INSTALLED R15+R9 PAINTED SOFFIT BOARD STRUCTURAL SHEATING NEW ROOF SHEATING MI N . 3 12" FL A N G E 4" MI N WALL SHEATHING BUILDING PAPER METAL LATH PLASTER (STUCCO) WEEP SCREED SLOPE GRADE 2% MIN. WEEP SCREED DETAIL SCALE: NTS 32 " ma x . 38 " mi n . 24" min 38 " mi n . 6" ma x . 48" min. SIDE BACK 32 " ma x . 38 " mi n . 24" min SIDE LOCATION OF GRAB BAR REINFORCEMENTS FOR ADAPTABLE BATHTUB 48 " M A X INTERIOR HEIGHTS ARE TO FINISH FLOOR EXTERIOR DOORBELL HEIGTH IS FROM OR LANDING TO TOP OF DOORBELL ASSEMBLY 48 " M A X . T O T O P OF O U T L E T B O X 15 " M I N . T O BO T T O M O F O U T L E T B O X HEIGHTS FOR ELECTRICAL RECEPTACLE OUTLETS, SWITCHES, DOORBELL BUTTONS, INCLUIDING HVAC CONTROLS 32 " m a x . 40" min.12" max. 26" min. 38 " m i n . LOCATION OF TOILET GRAB BAR 32 " m a x . 38 " m a x . 38 " SIDE 38 " 2x8 MIN. REINFORCEMENT BACK 38 " SIDE LOCATION OF GRAB BAR REINFORCEMENTS FOR ADAPTABLE SHOWER NOTE: THE DASH LINE REPRESENTS REINFORCED AREAS FOR INSTALLATION OF GRAB BARS FOR TYPICAL FIXTURE CONFIGURATION SCALE: 14" = 1' REINFORCEMENT FOR GRAB BARS -AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BE PROVIDED WITH REINFORCEMENT INSTALLED IN ACCORDANCE WITH THIS SECTION. WHERE THERE IS NO BATHROOM ON THE ENTRY LEVEL, AT LEAST ONE BATHROOM ON THE SECOND OR THIRD FLOOR OF THE DWELLING SHALL COMPLY WITH THIS SECTION. -REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING AGENCY. -REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH (51 MM BY 203 MM) NOMINAL LUMBER. [11/2 INCH BY 71/4 INCH (38 MM BY 184 MM) ACTUAL DIMENSION] OR OTHER CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD CAPACITY. REINFORCEMENT SHALL BE LOCATED BETWEEN 32 INCHES (812.8 MM) AND 391/4 INCHES (997 MM) ABOVE THE FINISHED FLOOR FLUSH WITH THE WALL FRAMING. -WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. -BATHUB AND COMBINATION BATHUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS ON EACH END OF THE BATHUB AND THE BACK WALL. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN 6 INCHES (152.4 MM) ABOVE THE BATHTUB RIM. NOTE: THE AREA OUTLINED IN DASHED LINES REPRESENT LOCATIONS FOR FUTURE INSTALLATION OF GRAB BARS FOR TYPICAL FIXTURE CONFIGURATIONS. SCALE: 14" = 1' AGE-IN PLACE DETAIL SCALE: NTS ELECTRICAL PLAN A-4 SCALE: 1/4" = 1'-0" FIRST FLOOR ELECTRICAL PLAN A PROJECT FOR: PROJECT ADDRESS: SHEET TITLE DATE: SHEET: PROJECT INFO PROJECT # DRAWN BY: CHECKED BY: SCALE: AS SHOWN AT T A C H E D A C C E S S O R Y DW E L L I N G U N I T 74 0 W S t . A N D R E W S P L A C E SA N T A A N A CA 9 2 7 0 7 - 2 6 2 1 REVISED BY: REVISIONS: DATE:BY: PROJECT: REVISED BY: DESIGNER: YMMAR BROWN ENGINEER: VISAL TE S/C SMOKE AND CARBON MONOXIDE ALARM. "SMOKE ALARM" SHALL BE INTERCONNECTED HARDWIRED WITH BATTERY BACKUP. "CARBON MONOXIDE ALARM" SHALL BE INTERCONNECTED HARDWIRED WITH BATTERY BACKUP. WHERE MORE THAN ONE ALARM IS REQUIRED TO BE INSTALLED WITHIN AN INDIVIDUAL DWELLING OR SLEEPING UNIT, THE SMOKE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. THE ALARM SHALL BE CLEARLY AUDIBLE IN ALL BEDROOMS OVER BACKGROUND NOISE LEVELS WITH ALL INTERVENING DOORS CLOSED. (CRC R314.4) WHERE MORE THAN ONE CARBON MONOXIDE ALARM IS REQUIRED TO BE INSTALLED WITH IN A DWELLING UNIT OR WITHIN A SLEEPING UNIT IN ACCORDANCE WITH SECTION R315.3, THE ALARM DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL DWELLING UNIT. PHYSICAL INTERCONNECTION OF CARBON MONOXIDE ALARMS SHALL NOT BE REQUIRED WHERE LISTED WIRELESS ALARMS ARE INSTALLED AND ALL ALARMS SOUND UP UPON ACTIVATION. CRC R315.5 SMOKE ALARM SHALL BE LISTED IN ACCORDANCE WITH UL 217. COMBINATION SMOKE AND CARBON MONOXIDE ALARM SHALL BE LISTED IN ACCORDANCE WITH UL 217 AND UL 2034 (CRC R314.1.1) CARBON MONOXIDE ALARMS SHALL BE LISTED IN ACCORDANCE WITH UL 2034 (CRC R315.5.1.1. GFCI s N N NEW GROUND FAULT CIRCUIT INTERRUPTER OUTLET NEW SWITCH NEW RECESSED LED LIGHT CEILING FAN W/ BACK DRAFT DAMPER 50 CU.FT/MIN. WITH HUMIDISTAT. N NEW WALL MOUNT LED LIGHT AFCI AFCI NEW ARC FAULT CIRCUIT INTERRUPTER / GROUND FAULT CIRCUIT INTERRUPTER OUTLETGFCI NEW ARC FAULT CIRCUIT INTERRUPTER. RECEPTACLES WITHIN 5'-6" FROM FLOOR ARE TO BE TAMPERED RESISTANT RECEPTACLES. ELECTRICAL LEGEND WP AFCI NEW OUTSIDE WEATHERPROOF WHOLE HOUSE IAQ FAN, 60 CFM MIN. (MAXIMUM SOUND RATING 1 SONE. FAN SHALL BE RATED FOR CONTINUOUS USE AND IS LABELED TO INDICATE IT AS INTENDED TO OPERATE CONTINUOUSLY WHILE THE HOUSE IS OCCUPIED. THE CFM RATING FOR THE I.A.Q FAN WILL BE PER ENERGY SPECIFICATION) H s NV NEW VACANCY SENSOR SWITCH VENTILATION FAN 50 CFM MIN. WITH HUMIDISTATF SCALE: 1/4" = 1'-0" SECOND FLOOR ELECTRICAL PLAN N N s s s GFCI AFCI N N N N N N N N S/C N s N AFCI GFCI s N AFCI GFCI AFCI GFCI NN NN s S/C s NN NN s N N N s N N N N NN s N N s AFCI GFCI AFCI GFCI N N s AFCI GFCI AFCI GFCI AFCI GFCI AFCI GFCI AFCI GFCI AFCI GFCI AFCI GFCI AFCI GFCI s N S/C S/C N N sNV NV NV NV NV NV NV NV NV NV NV F F SCALE: 1/4" = 1'-0" SECTION A-A 1 1 1 1 3 1 R-15 R-15 R-15 + R-9 - (AIR-IMPERMEABLE PER T-24) MINI-SPLIT (IN-DOOR AIR HANDLER HEATING/COOLING) W/P 125 VOLT 120/240 VOLT 3 CONDUCTOR 10 AWG COPPER BRANCH CIRCUIT, WITHIN 3 FEET OF THE WATER HEATER AND ACCESSIBLE TO THE WATER HEATER. 2 3 NOTE LEGEND SCALE: 1/4" = 1'-0" SECTION B-B 10/16/2024 YB s 4 4 4 4 AFCI GFCI 5 5 6 WALL MOUNTED TANKLESS WATER HEATER. STACKED WASHER DRYER, PROVIDE METAL PAN WITH DRAIN TO DRAIN OR DAY LIGHT MINI SPLIT CONDENSER (HEAT PUMP). SEE SHEET G RESIDENTIAL KITCHENS SHALL BE PROVIDED WITH AN EXHAUST SYSTEM CAPABLE OF EXHAUSTING A MINIMUM OF 100 CFM OR 50 CFM WITH A CONTINUOUS OPERATING SYSTEM. CMC TABLE 403.7. 100 AMP ELECTRICAL PANEL DEDICATED - NEW 240 VOLT GFCI. UNDERSIDE OF ROOF EAVE MUST BE 1-HR FIRE RATED PER DETAIL 1/A-3 8 10 7 11 NOTE LEGEND (CONT'D) 9 6 7 8 9 10 S/C 11 F 11 12 12 H s NV sNV sNV (E) HOUSE 1202 SQ.FT EXISTING MAIN HOUSE PLAN & PERSPECTIVES A-5 A PROJECT FOR: PROJECT ADDRESS: SHEET TITLE DATE: SHEET: PROJECT INFO PROJECT # DRAWN BY: CHECKED BY: SCALE: AS SHOWN REVISED BY: REVISIONS: DATE:BY: PROJECT: REVISED BY: DESIGNER: YMMAR BROWN ENGINEER: VISAL TE SCALE: 1/4" = 1'-0" (E) MAIN HOUSE ROOF PLAN SCALE: 1/4" = 1'-0" (E) MAIN HOUSE FLOOR PLAN EXISTING MAIN HOUSE PLANS ARE FOR REFERNCE ONLY, NO CONSTRUCTION WILL BE DONE. "NOT IN SCOPE" SCALE: 1/4" = 1'-0" (E) MAIN HOUSE FRONT PERSPECTIVE SCALE: 1/4" = 1'-0" (E) MAIN HOUSE SIDE PERSPECTIVE SCALE: 1/4" = 1'-0" (E) MAIN HOUSE REAR PERSPECTIVE YB 2023/09/24 SL AT T A C H E D A C C E S S O R Y DW E L L I N G U N I T 74 0 W S t . A N D R E W S P L A C E SA N T A A N A CA 9 2 7 0 7 - 2 6 2 1 S0.1 Sheet Date Scale PROJECT: Job Drawn M.G. Sheet Title BYREVISIONS AS SHOWN DE T A C H E D A C C E S S O R Y D W E L L I N G U N I T DATESUBMITTAL PLAN CHECK SUBMITTAL TYPICAL DETAILS NOTES: 1.PROVIDE TOP MOUNT HANGERS. FACE MOUNT HANGERS SHALL BE ALLOWED ONLY WHERE SPECIFICALLY INDICATED ON THE PLANS OR DETAILS 2.PROVIDE SKEWED, SLOPED HANGERS AS REQ'D. ALL SAWN LUMBER U.N.O. 2X6 THRU 2X16 (2) 2X6 THRU (2) 2X14 4X6 THRU 4X14 ALL I-JOIST U.N.O. SINGLE I-JOIST TO WOOD BEAM 9 1 4 THRU 16 DEEP ALL PSL/LVL/LSL BEAM U.N.O. 3 1 2" AND 5 1 4" PSL/LVL/LSL UP TO 11 7 8" DEEP ALL GLULAM BEAMS U.N.O. SIMPSON 'HUTF' SIMPSON 'LB' SIMPSON 'HUSTF' SIMPSON 'LBV' SIMPSON 'ITS' SIMPSON 'HGLTV' SIMPSON 'GLTV' SIMPSON 'EG' ESR-2553 COLA RR25800 ESR-2553 COLA RR25800 ESR-2553 COLA RR25800 ESR-2553 COLA RR25800 ESR-2615 COLA RR25803 ESR-2615 COLA RR25803 ESR-2615 COLA RR25803 ESR-2615 COLA RR25803 ESR-2615 COLA RR25803 SIMPSON 'HUSTF' JOIST/BEAM SIZE HANGER TYPE TOP MOUNT HANGER (SEE NOTE 1) ALL SAWN LUMBER U.N.O. 2X6 THRU 2X16 (2) 2X6 THRU (2) 2X14 4X6 THRU 4X14 ALL I-JOIST U.N.O. SINGLE I-JOIST TO WOOD BEAM 9 1 4 THRU 16 DEEP ALL PSL/LVL/LSL BEAM U.N.O. 3 1 2" AND 5 1 4" PSL/LVL/LSL UP TO 11 7 8" DEEP ALL GLULAM BEAMS U.N.O. SIMPSON 'HU' SIMPSON 'LUS' SIMPSON 'HHUS' SIMPSON 'MIU' SIMPSON 'IUS' SIMPSON 'HGU' SIMPSON 'MGU' SIMPSON 'HHGU' ESR-2549 COLA RR25807 ESR-2549 COLA RR25807 ESR-2549 COLA RR25807 ESR-2552 COLA RR25801 ESR-2552 COLA RR25801 ESR-2552 COLA RR25801 ESR-2552 COLA RR25801 ESR-2552 COLA RR25801 ESR-2552 COLA RR25801 JOIST/BEAM SIZE HANGER TYPE FACE MOUNT HANGER (SEE NOTE 1) SIMPSON 'LUS' HANGER SCHEDULE - MANUFACTURER: SIMPSON STRONGTIE N.T.S.15PIER WALL ** * ** ** * * 7 1 2 3 4 5 NO. PANEL WALL SHEAR W/ 10d COMMON 1/2" STRUCT. 1 PLYWD./OSB PANEL OR 16d 5/8" x 9" LAG SCREWS SIMP. SDS 1/4"Ø x 6" OR FLOOR PLATE FASTERNERS OR 16d 5/8" x 9" LAG SCREWS SIMP. SDS 1/4"Ø x 6" OR FLOOR PLATE FASTERNERS FACE SIDE ONE SIDE ONE SIDE ONE SIDE ONE SIDES TWO SIDES TWO SIDES TWO NAILING @ PANEL EDGE FIELD MEMBER EDGE FASTERNERS SIZE SPACING PLATE SIZE EXTERIOR TYPE SPACING TYPE SPACING INTERIOR FASTERNERS SIZE SPACING 5/8"Ø x 3/4"Ø ANCHORS ANCHOR BOLTS @ SILL PLATE (PLF) SHEAR ALLOWABLE (PLF) SHEAR ALLOWABLE 6" 4" 4" 4" 6" 4" 4" 6" 8" 3" 8" 8" 8" SDPWS-15SDPWS-15 STAGG. 3" STAGG. 2" STAGG. 3" STAGG. 2" 12" 12" 12" 12" 12" 12" 12" MIN. 3x MIN. 3x MIN. 3x MIN. 3x MIN. 3x MIN. 4x MIN. 4x 16d SDS 1/4"Ø SDS 1/4"Ø SDS 1/4"Ø SDS 1/4"Ø LAG 5/8"Ø LAG 5/8"Ø MIN. 2x MIN. 3x MIN. 3x MIN. 3x MIN. 3x MIN. 3x MIN. 3x LTP4 LTP4 LTP4 LTP4 LTP4 A35 A35 16" 16" 2 SIDES 8" 2 SIDES 8" A35 A35 A35 A35 A35 A35 A35 8" 8" 8" 16" 16" 2 SIDES 8" 2 SIDES 8" 5/8" Ø 5/8" Ø 5/8" Ø 5/8" Ø 5/8" Ø 3/4" Ø 7/8" Ø FOR 2x 32" 32" 16" 16" 16" 16" 16" MIN. 2x MIN. 3x MIN. 3x MIN. 3x MIN. 3x MIN. 3x MIN. 3x 340 510 665 870 1020 1330 1740 475 715 930 1217 1430 1860 2435 SHEAR PANEL SCHEDULE SILL PLT. SIZE (SEISMIC)(WIND) 2 1/2" MIN. 2'-0" MIN. 3" CLR. 3" CLR. 1/2" MIN. 2" TO 3" SPACING RAISED FLR. FTG. SLAB FTG. NAILING PATTERN AT PANEL JOINT (FOR 2" AND 3" NAIL SPACINGS) SHEAR PANEL SCHEDULE 1 NOTES: PLYWD. SPLICE 3x BLKG @ EDGE NAILING EDGE NAILING 2 ROWS OF PANEL EDGE 3x STUD @ PLATE 3x BOT. (U.N.O.) 3x BLKG. TOP PLATES CONT. DBL EDGE NAILING 2 ROWS OF PLYWD. SPLICE 3x BLKG @ PLATE 3x BOT. PER PLAN FLOOR JOIST PER PANEL SCH. SILL PLATE W/ A.B. 3x PRESS. TREATED CONT. DBL TOP PLATE 2x STUDS @ 16" O.C. FIELD NAILING 2 ROWS OF EDGE NAILING EDGE NAILING FLOOR JOIST PER PLAN PANEL EDGE 3x STUDS @ EDGE NAILING FIELD NAILING PER PANEL SCH. SILL PLATE W/ A.B. HOLDOWN IF REQ'D PLYWD. PANEL JOINT 3x MIN. @ FLOOR SHEATHING, TYP. U.N.O. PROVIDE MINIMUM 3 IN. PENETRATION INTO MEMBERS BELOW 10. USE 3x AND TREATED SILL PLATE AT CONCRETE SURFACES,TYP.9. ALL NAILS SHALL BE COMMON NAILS, TYP.8. A MINIMUM OF 5d CONCRETE COVER AND 10" MIN. EMBEDMENT. ALL ANCHOR BOLTS AT EDGE OF CONCRETE SHALL HAVE7. ENDS AND EDGES. AND A MINIMUM 1/2" EDGE NAILING DISTANCES AT PANEL OF THE CONNECTING MEMBER FOR SHEAR PANEL PANEL EDGE AND AT LEAST 3/8" FROM THE EDGE NAILS SHALL BE PLACED AT LEAST 3/8" FROM6. USE PLT. 1/4"x3" SQ W/ 5/8" & 3/4" DIA. A.B.5. MORE THAN 1-5/8". COMMON NAILS ARE SPACED 3" O.C. PENETRATE FRAMING EDGES. WHEN NAIL SPACING IS 2" O.C. OR WHEN 10d NAIL SHALL BE STAGGERED IN TWO LINES ALONG PANEL WALL FRAMING TO BE MIN. 3x MEMBER AT PANEL EDGES.4. 3. FOR HOLD DOWN ANCHOR (HD) SEE PLAN & DETIAL PLYWOOD WITH MIN. 5-PLY. ALL PLYWOOD SHEAR PANELS TO BE 1/2" STRUC I2. SEE FRAMING PLANS FOR LOCATION OF SHEAR PANELS1. NO SCALE 6 12/30/24 12/30/2024 UN I T 74 0 W S t . A N D R E W S P L A C E SA N T A A N A CA 9 2 7 0 7 - 2 6 2 1 S0.2 2811 SCALE: 1"=1'-0"9 SCALE: 1"=1'-0"3 SCALE: 1"=1'-0" SCALE: 1"=1'-0" 10SCALE: 1"=1'-0" SCALE: 1"=1'-0" 7 SCALE: 1"=1'-0" SCALE: 1"=1'-0"12 SCALE: 1"=1'-0"1TYPICAL WALL FRAMING DETAIL 6SCALE: 1"=1'-0" REBAR AT INTERSECTION ANGLECORNER DOUBLE CURTAIN END INTERSECTION LENGTH OF BENDS SHALL BE LARGER OF 18" OR PER ANGLE CORNER INTERSECTION END SINGLE CURTAIN S0.2 3 TYPICAL REBAR INFORMATION 135° BEND D1 90° BEND D1 6d # 3 - # 5 12d # 6 - # 8 OR 2 1/ 2 " M I N . 6d # 3 - # 5 12 D # 6 - # 8 OR 2 1 / 2 " M I N . d D d D TIE WIRE 6 d 1 12 d 180° BEND 4d OR 2 1/2"MIN. D MINIMUM BEND DIAMETERS D=6d FOR #3 THRU #8 D=8d FOR #9 THRU #18 MINIMUM INSIDE STIRRUP & TIES MIN BEND DIAMETERS D1= 4d FOR #3 THRU #5 D1= 6d FOR #6 THRU #8 TYPICAL STIRRUPS AND TIES OFFSET AND SPLICES 36d (18"MIN.) CONC. 48d (24"MIN.) IN MASONRY 48d (24"MIN.) @ GRADE BEAMS TYPICAL HOOKS AND BENDS TYPICAL ANCHOR BOLTS AT SILL PLATE FRAMING NOTCHING DIAMETER="W"/4 MAX. WOOD STUD 6" M I N . 'W' NOTCHING OF JOIST AND RAFTERS IS NOT ALLOWED JOIST / RAFTER 2'D' MIN. 'D ' 'D ' / 2 DIAMETER='D'/6 MAX. (8) 16d EA. SIDE OF NOTCH (4 EA. PLATE) WHERE NOTCH IS GREATER THAN 1" PROVIDE 12 GA. STRAP SAME WIDTH AS DBL TOP PLATE DOUBLE TOP PLATE 'B ' 'B ' / 2 3" MAX. 5"5" WHERE DEPTH 'b' OF NOTCH IS GREATER THAN 'B'/5 PROVIDE ANCHOR BOLT EA. SIDE SILL PLATE 5" MIN. 9" MAX. 5" MIN. 9" MAX. 5" MIN. 9" MAX. 'b ' 'B ' DIAMETER= 'B'/2 MAX. STUD WALL AT CORNERS NOTE: PROVIDE REQ'D. DBL STUDS OR POSTS WHERE A.B. OCCUR 2X STUD @ 16" O.C., TYP. PROVIDE 16d @ 12" O.C., STAGG. TYP. 2X STUD @ 16" O.C., TYP. PROVIDE 16d @ 12" O.C., STAGG. TYP. TOP PLATE SPLICE 4'-0" MIN. SPLICE OVER STUD TYP. 16d @ 12" O.C. INTERM. NAILING. (13)-16d @ EA. SIDE OF SPLICE, TYP. NOTE: BALANCE OF NAILING PER 2013 CBC, TABLE 2304.9.1, OR DETAILS. NOTE: PROVIDE 2x FIRE STOPS @ CEILINGS, FLOORS, AND @ 8'-0" O.C. MAX. VERTICALLY. (2)16d MIN. (ADD'L. (2) 16d FOR EA. ADD'L. 2" OF HDR. DEPTH) 2x STUDS @ 16" O.C. 2X JAMBS (1) AT OPNG. LESS THEN 4'-0" (2) AT OPNG. 4'-0" TO 6'-0" (3) AT OPNG. 6'-0" TO 10'-0" 2x FIRE STOPS AT 8'-0" O.C. VERT. & HORZ. TYP. DBL. STUDS OR POST @ HOLDOWNS-SEE PLAN WHERE OCCURS DBL.2x TOP PLATE SIMPSON 'A34' @ OPENINGS WIDER THAN 8'-0" HEADER, SEE PLAN 2x TRIMMER: (1) @ 5 1/ 4" OR LESS HDR. DEPTH (2) @ 7 1/ 4" OR GREATER HDR. DEPTH 4x POST @ GLB OR PSL HDRS.(2) 10d T.N. 2x SILL WHERE OCCURS (DBL. 2x SILL @ OPNGS. WIDER THAN 4'-0") 16d @ 12" O.C., TYP. SILL PLATE KING POST DETAIL KING POST PER PLAN SIMPSON 'EPC' POST CAP BEAM PER PLAN SIMPSON 'PC' POST CAP INVERTED BEAM PER PLAN KING POST PER PLAN SIMPSON 'EPC' POST CAP BEAM PER PLAN SIMPSON 'PC' POST CAP INVERTED BEAM PER PLAN 'd ' 'd''d''d'PER PLANS 36" O.C., MAX., SEE ALSO SHEAR WALL SCHED. FOR A.B. SPAC'G. IN THOSE AREAS 1-3/4", MIN., TYP. 1- 3 / 4 " , M I N . , TY P . 5/8"Ø, MIN., X 10" MIN. EMBED. A.B. PER PLAN, 36" O.C., MAX. (REFER TO SHEAR WALL SCHED. FOR A.B. SIZE AND SPAC'G. OF A.B.) WHERE PLATE IS NOTCHED OR DRILLED MORE THAN 1/3 OF THE WIDTH OF THE PLATE, PROVIDE ADDITIONAL A.B. AT EA. SIDE 'd' DISTANCE FROM THE EDGE OF THE NOTCH OR DRILLED HOLE. CONT. 2X OR 3X P.T. SILL PLATE PER PLAN CONT. FTG., OR STEM WALL BELOW, TYP. 5/8"Ø, MIN., A.B., TYP. HOLES IN PLATE WASHERS SHALL BE PERMITTED TO BE DIAGONALLY SLOTTED WITH A WIDTH OF UP TO 3/16" LARGER THAN THE BOLT DIAMETER AND THE SLOT LENGTH NOT TO EXCEED 1-3/4", PROVIDED A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND THE NUT. MAY USE SIMPSON 'BPS' WASHER, SIZE PER A.B. REQ. PLATE WASHER, PER PLAN, TYP. PLATE WASHER, PER PLAN, TYP. PLY. SHEAR WALL PLY. SHEAR WALL 1/ 2 " 1/2" 1/2" PLATE WASHER SHALL EXTEND TO WITHIN 1/2" OF THE EDGE OF THE WOOD SILL PLATE ON T HE SIDE(S) FOR SHEATHING WITH SHEAR DESIGN VALUES EXCEEDING 400 PLF NOTES: 1.MINIMUM SPLICE LENGTH FOR BARS WITH CLASS 'B' SPLICE PER ACI-318-14, SECTION 12.2. 2.TOP BARS ARE HORIZONTAL BARS WITH MORE THAN 12" CONCRETE CAST IN THE MEMBER BOLOW THE REINFORCEMENT. 3.THESE BAR DEVELOPMENT LENGTH APPLY TO REGULAR OR NORMAL WEIGHT CONCRETE, MULTIPLY THE SPECIFIED DEVELOPMENT LENGTH BY 1.33 FOR LIGHT WEIGHT CONCRETE. 4.ALL DETAILING OF REINFORCEMENT SHALL COMPLY WITH THESE SCHEDULES UNLESS SPECIFICALLY DETAILED ON THE DRAWINGS. TYP. REINF. DEVELOP. LENGTH SCHED. Sheet Date Scale PROJECT: Job Drawn M.G. Sheet Title BYREVISIONS AS SHOWN DE T A C H E D A C C E S S O R Y D W E L L I N G U N I T DATESUBMITTAL PLAN CHECK SUBMITTAL TYPICAL DETAILS 12/30/24 12/30/2024 UN I T 74 0 W S t . A N D R E W S P L A C E SA N T A A N A CA 9 2 7 0 7 - 2 6 2 1 S0.3 2635 SCALE: 1"=1'-0"27 SCALE: 1"=1'-0"34SCALE: 1"=1'-0" SCALE: 1"=1'-0" SCALE: 1"=1'-0"31 28 SCALE: 1"=1'-0" NTS 36 SCALE: 1"=1'-0"25 30SCALE: 1"=1'-0"PIPE AT FOOTING 9" MIN. 24" MIN. TY P . FT G . SE E PL A N TRENCH 3" CL R . NO EXCAVATION BELOW THIS LINE NOTE: NO PIPE SHALL PASS THROUGH FOOTING. PROVIDE SLEEVE MIN. 1" Ø LARGER THAN PIPE. SECTION A-A SLEEVE PIPE A A TYPICAL POST BASE ISOLATED POST BASE POST BASE (POST PART OF WALL) SILL BOLT SEE WOOD NOTE, OR SHEAR WALL SCHEDULE FOR SIZE SIMPSON POST BASE W/ BOLTS WOOD POST SEE PLAN 2X PLATE CONT. WOOD STUDS SEE PLAN SIMPSON 'A35' AT OPP. CORNERS TOP OF CONC. SLAB OR FTG. WOOD POST SEE PLAN Sheet Date Scale PROJECT: Job Drawn M.G. Sheet Title BYREVISIONS AS SHOWN DE T A C H E D A C C E S S O R Y D W E L L I N G U N I T DATESUBMITTAL PLAN CHECK SUBMITTAL CONNECTION AT TOP NON-BEARING STUD WALLNON-BEARING STUD WALL 2X BLOCKING @ 24" O.C.JOIST OR RAFTER JOIST OR RAFTER 'STC' PER JOIST PERPENDICULAR TO JOIST B PARALLEL TO JOIST A TYPICAL NON-BEARING STUD WALL 'STC' EA. BLK'G. NON-BEARING WALL BASE DETAIL TOP OF CONC. SLAB OR FTG. NON BEARING WALL 2X P.T. SILL PLATE W/ 3 16"Ø RAMSET/RED HEAD POWER-DRIVEN FASTENERS @ 32" O.C. W 1 1 2" MIN. EMBED. (LARR #22668, ICC ESR-1799) EDGE WHERE OCCURS TYPICAL CONNECTION AT CEILING JOIST HANGER R.R.. PER PLAN ROOF PLY., PER PLAN SEE FOR ITEMS NOT NOTED TYPICAL CEILING JOIST DETAIL CEILING JOIST SCHEDULE 2X CONT. LEDGER W/ - (2) SDS25412 (SPAN "D"&"E") - (3) SDS25412 (SPAN "A","B", &"C") AT EA. END STUD WALL SEE PLAN CEILING JOIST SUPPORT TJI JOIST OR RAFTER OR SAWN LUMBER JOIST @ 24" O.C. MAXIMUM SPACING (SEE PLAN) CONTINUOUS 1X6, (2) 8d EACH CEILING JOIST 2X4 HANGER JOIST SUPPORT AT EACH CEILING JOIST W/ (3) 8d EACH END PLYWOOD FILLER AT TJI W/ (3) 8d FACE NAIL AND (3) 8d BACK NAILING (OMIT AT SAWN LUMBER) SPAN # A B D 20'-0" 16'-0" 12'-0" 2X8 @ 16" O.C. CEILING JOIST PER PLAN SAME SPACING AS FLOOR OR ROOF JOIST SEE PLAN 2X10 @ 16" O.C. C CEILING JOIST SIZE AND SPACINGMAX. SPAN BETWEEN SUPPORTS 8'-0"2X4 @ 16" O.C. 2X6 @ 16" O.C. E 24'-0"2X12 @ 16" O.C. HANGER PER S0.1 SECTION AT STUD WALL PARALLEL TO CEILING JOIST E.N. SHR. WALL PER PLAN 2X BLKG. @ 48" O.C. W/ (2)-16d @ C.J. & (2)-10d @ STUD C.J. PER PLAN S.W. PER PLAN TO MATCH BELOW WHERE OCCURS STUD WALL TO MATCH WALL BELOW 2X PLATE AT S.W. W/ SOLE PLATE FASTENER PER S.W. SCHED. TYPICAL FLUSH BEAM DRAG CONNECTION SHEARWALL END POST PER PLAN SHEARWALL PER PLAN DOUBLE TOP PLATE 16d NAILING STRAP PER PLAN. ('MST48' MIN.) BEAM PER PLANPLYWOOD SHT'G. PER PLAN BEAM OR BLK'G. TYPICAL DETAILS 'T ' / 4 PLAN 'T ' 12 ' - 0 " O . C . M A X . TY P . A SECT. B-B SECT. A-A B B A 1 2" Ø X 3'-0" SMOOTH DOWEL @ 32" O.C. GREASE ONE END NOTE: CONTRACTOR SHALL LOCATE JOINTS ALONG COLUMN LINES WHENEVER POSSIBLE. 1 8" WIDE SAW CUT JOINT CONSTRUCTION JOINT CONTROL JOINT TYPICAL SLAB ON GRADE DETAIL SLAB ON GRADE TYPICAL CONSTRUCTION JOINT (WHERE CONTINOUS POUR IS USED) B A 1 8" WIDE x T/4" DEEP PRE FORMED STRIP OR SAW CUT THE SAME DAY OF THE POUR DEPRESS REINFORCEMENT UNDER JOINT AS REQUIRED TO CLEAR STRIP OR SAW CUT SEE PLAN FOR SLAB REINF. (TYP., U.N.O.) PROVIDE 4-INCH THICK BASE OF 1/2 INCH OR LARGER CLEAN AGGREGATE VAPOR BARRIER IN CONTACT WITH CONCRETE COLD JOINT STOP REINF AT JOINT #4 DIA. X 2'-0" LONG PLAIN DOWEL @ 18" O.C. GREASE ONE SIDE SLAB REINFORCING SEE PLAN, TYP. SEE INSET DETAIL A/- "T " "T " / 2 "T " "T " / 2 1 1 2" C L R . 12"12"12"12" NOTE: 1.CONTROL JOINTS TO BE LOCATED AT COLUMN CENTER LINES AND AT 20'-0" O.C. MAX. AND EVERY 400 SQUARE FEET. 2.IF SAW-CUT CONTROL JOINT TO BE USED, SAW-CUT WITHIN 24 HOURS OF POUR. 3.SEE PLAN FOR "T". SLAB ON GRADE AND CONTROL JOINT AND CONTROL JOINT SCALE: 1"=1'-0"32 12/30/24 12/30/2024 UN I T 74 0 W S t . A N D R E W S P L A C E SA N T A A N A CA 9 2 7 0 7 - 2 6 2 1 B C D E H 1 2 3 4 5 7 8 A 1 4 7 8 H G B A F B C D F H 1 7 86 1 7 86 H B B C D E H 1 2 3 4 5 7 8 A 1 4 7 8 H G B A F 1 2 3 4 5 6 7 8 9 10 LANDING 5 6 7 8 9 10 11 12 13 15 16 17 14 LANDING LANDING FRAMING NOTES:FOUNDATION NOTES: Sheet 03/03/25Date Scale PROJECT: Job Drawn M.G. Sheet Title BYREVISIONS AS SHOWN DE T A C H E D A C C E S S O R Y D W E L L I N G U N I T DATESUBMITTAL 12/30/2024PLAN CHECK SUBMITTAL 03/03/2025PC SUBMITTAL #2 04/28/2025PC SUBMITTAL #3 PC #3 LEGENDS SCALE: 1/4"=1'-0" FOUNDATION PLAN SCALE: 1/4"=1'-0" ROOF FRAMING PLAN SCALE: 1/4"=1'-0" 2ND FLOOR FRAMING PLAN # L=#'-#" FRAMING LEGEND 1ST FLOOR PLAN BELOW 2ND FLOOR PLAN BELOW B C D F H 1 7 86 1 7 86 H B 1 2 3 4 5 6 7 8 9 10 LANDING F. J . - 1 F . J . - 1 HDR. HDR. HDR. [H D R . - 2 ] HDR. HDR. HDR. F . J . - 1 4x8 R.R.-1R.R.-1 4 S3.0 1 L=6'-1" 10 S3.0 10 S3.0 2 S3.0 2 S3.0 1 S3.0 1 S3.0 1 L=13'-8" BM-2 BM-2 F . J . - 1 1 L=18'-6" 1 L=4'-4" 1 L=13'-8" 1 L=18'-6" 1 L=4'-4" 6x 8 21 S2.1 HD R . 18 S2.1 1 L= 1 3 ' - 0 " 1 L= 5 ' - 0 " R. B M . - 1 4x 8 4x 8 4x8 1 S2.09 S2.0 9 S2.0 9 S2.0 13 S2.1 13 S2.1 13 S2.1 5 S2.0 5 S2.0 6 S2.0 22 S2.1 23 S2.1 12 S3.0 10 S3.0 7 S3.0 6 S3.0 1 L=17'-8" LO W R O O F R. R . - 1 4x8 3x LEDGER 6x 8 4x8 HD R . HD R . 3 L= 3 ' - 5 " 1 L= 1 3 ' - 0 " 1 L= 1 3 ' - 0 " 3 L= 3 ' - 5 " 3 L= 3 ' - 5 " 3 L= 3 ' - 5 " HDR. 9 S3.0 9 S3.0 6 S3.0 6 S3.0 6 S3.0 4 S2.0 6 S2.0 12 S2.0 20 S2.1 21 S2.1 6 S3.0 6 S3.0 11 S3.08 S3.0 5 S3.0 3 S3.0 3 S3.0 5 S3.0 11 S3.0 11 S3.0 15 S2.1 1 L=4'-4" 1 L=4'-4" 23'-0" 21 ' - 9 " 23'-0" 23'-0" 21 ' - 9 " 23'-0" 23'-0" 21 ' - 9 " 23'-0" 16'-6"3'-0"3'-6" 5 S3.0 5 S3.0 6 S2.0 12 ' - 4 " 4' - 7 " 7' - 6 " S1.0 1.PROVIDE SINGLE TRIMMER EACH END OF 4X6 OR LESS HEADER OR BEAM & WOOD POST EACH OF 4X8 OR GREATER HEADERS OR BEAM, TYPICAL UNLESS NOTED OTHERWISE. 2.ALL EXTERIOR WALL SHALL BE 2X4 MIN. STUDS @ 16" O.C., UNLESS NOTES OTHERWISE. 3.FOR TYPICAL STUD WALL FRAMING SEE DETAIL 10/S0.2. 4.PROVIDE MULTIPLE STUDS UNDER MULTIPLE JOISTS, RAFTERS OR TRUSSES. 5.PROVIDE BOUNDARY NAILING ALONG ALL DRAG MEMBERS, UNLESS NOTED OTHERWISE. 6.SEE ARCHITECTURAL PLAN FOR ALL DIMENSIONS AND CONDITIONS NOT SHOWN. 7.ROOFING MATERIAL SHALL NOT EXCEED 8.0 PSF. 8.FASTENERS FOR PRESERVATIVE TREATED AND FIRE-RESISTRDANT-TREATED WOOD SHALL BE OF HOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. THE COATING WEIGHTS FOR ZINC-COATED FASTENERS SHALL BE IN ACCORDANCE WITH ASTM A 153. FASTENERS OTHER THAN NAILS, TIMBER RIVETS WOOD SCREWS AND LAG SCREWS SHALL BE PERMITTED TO BE OF MECHANICALLY DEPOSITED ZINC COATED STEEL WITH COATING WEIGHTS IN ACCORDANCE WITH ASTM B 695, CLASS 55 MINIMUM. 9.GABLE END WALLS SHALL BE BALLOON FRAMED TO ROOF DIAPHRAGM. ROOF SHEATHING NOTE 1.THE TYPICAL ROOF SHEATHING SHALL BE 15/32" APA RATED PLYWOOD (P.I. 24-16) WITH 10d COMMON NAILS @ 6"O.C. BOUNDARIES AND CONT. PANEL EDGES, 6"O.C. OTHER PANEL EDGES, AND 12"O.C. FIELD NAILING. 2.ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS WITH SHEETS STAGGERED. 1.SEE FOUNDATION NOTES ON SHEET S0.0 FOR DESIGN SOIL BEARING PRESSURE, ETC.. 2.SEE ARCHITECTURAL PLANS FOR DIMENSIONS AND CONDITIONS NOT SHOWN. 3.ALL HOLDOWNS AND ANCHOR BOLTS AT SHALL BE SET IN PLACE BY TEMPLATE PRIOR TO FOUNDATION INSPECTION. 4.WOOD PATIO COVER COLUMN BASES SHALL BE A MINIMUM OF 1 INCH STAND-OFF OF FINISH SURFACE FOR MOISTURE PROTECTION. 5.ALL WORK SHALL CONFORM TO THE 2022 CALIFORNIA BUILDING CODE (2022 CBC). 6.ALL HOLDOWN BOLTS SHALL BE RE-TIGHTENED JUST PRIOR TO COVERING THE WALL FRAMING. 7.ALL CONNECTORS AND / OR FASTENERS IN CONTACT WITH PRESSURE TREATED LUMBER SHALL BE HOT DIPPED GALVANIZED (ASTM 123 & 153) G85 MINIMUM AND FOR MECHANICAL GALVANIZING (ASTM B695) MARK WIDTH THICKNESS REINFORCEMENT DEPTH NOTE: 1. ALL CONCRETE TO BE Fc=3000PSI, MIN. 2. BOTT. OF FTG'S. TO BE 24", MIN. BELOW LOWEST ADJACENT GRADE SILL PLATE NOTE: ALL FASTENERS IN CONTACT W/ PRESSURE TREATED SILL SHALL BE GALVANIZED (ANCHOR BOLTS, NAILS, ETC.) TYPICAL CONCRETE SLAB ON GRADE SHALL BE 4" THICK WITH #4 @ 16" O.C. EA. WAY MID HT. OVER 2" SAND OVER AN 10 MIL. VISQUEEN VAPOR BARRIER OVER 4" OF SAND, OVER COMPACTED GRADE. SEE 32/S0.3 CONTINUOUS FOOTING SCHEDULE MARK WIDTH DEPTH REINFORCEMENT TIES NOTE: 1. BOTTOM OF ALL FOOTINGS SHALL EXTEND 27", MIN. INTO FIRM CERTIFIED FILL OR BEDROCK. 2. ALL CONCRETE TO BE Fc=3000 PSI, MIN. PAD FOOTING SCHEDULE NEW EXTERIOR WALL 2 X 6 MINIMUM STUDS @ 16" O.C. ( INTERIOR WALL SHALL BE 2X4 @ 16" O.C.) SHEAR WALL NOTATION PER SHEAR WALL SCHEDULE AT SHEET S0.1 DETAIL 1 (SHEAR PANEL SCHEDULE) INDICATES NEW CONTINUOUS FOOTING, PER 'CONTINUOUS FOOTING SCHEDULE' F-1.5 18" SQ.24"(3)-#5 BARS EA. WAY, TOP & BOTT.24" FOUNDATION, 2ND FLOOR, AND ROOF FRAMING PLAN FLOOR SHEATHING NOTE (PATCHING / REPAIR AS REQUIRED) 1.THE TYPICAL FLOOR SHEATHING SHALL BE 3/4" T&G APA RATED PLYWOOD (P.I. 24-16) WITH 10d COMMON NAILS @ 6"O.C. BOUNDARIES AND CONT. PANEL EDGES, 6"O.C. OTHER PANEL EDGES, AND 12"O.C. FIELD NAILING 2.FLOOR DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS WITH SHEETS STAGGERED. INDICATES (E) WALL FLOOR AND ROOF JOISTS (SEE FRAMING LEGENDS) BEAM OR HEADER (FOR HEADER SEE FRAMING LEGENDS) R.BM.-1 5.25x11.875 PSL R.R.-1 2x6 @ 16" O.C. HDR.6x6 DFL. No. 1 PER CRC TABLE R802.4 F.J.-1 2x8 @ 16" O.C. CEILING JOISTS (SEE FRAMING LEGENDS) 1'-0"24" MIN.(2) #5 BARS @ TOP AND BOTTOMCF1.0 NONE 4X4 HDU2 4X4 HDU2 4X4 HDU2 6x6 HDU8 TYP. AT 'HDU' TO (E) FTGS 4x4 MST 4 8 4X4 HDU2 6x6HDU 8 4x4 (E) CONT. FTG., TO REMAIN, TYP. (E) 12" WIDE CONT. FTG., TO REMAIN, TYP. (E) CONT. FTG., TO REMAIN, TYP. 6x6 HDU8 4X4 HDU2 4X4 HDU2 4X4 HDU2 4X4 HDU2 4x4 6x6 HDU 8 4X4 HDU2 4X4 HDU2 4x4 4x4 PROVIDE 2x14 STRINGERS @ 16" O.C., MAX SPAC'G. SEE TYP. @ STAIR F-1.5 4x4 MST 4 8 4x4MST 4 8 4x4 4x4 ECC Q 4x4 ECC Q 4x4 MST 4 8 4x4MST 4 8 4x4MST 4 8 (E) CONC. SLAB ON GRADE, TO REMAIN. PROVIDE REDGARD VAPOR RETARDER ESR- 1413 CF1.0 BM-2 5.25X11.875 PSL TYP. AT 'HDU' TO (N) FTGS TYP. AT (N) FTG TO (E) FTG. TYP. @ MST [HDR.-2] OPEN 4x4MST 4 8 4x4 P O S T ABV . 4x4 P O S T ABV . 4x44x44x44x44x44x44x4 P O S T ABV .4x4 P O S T ABV . 4x4 P O S T ABV .4x4 P O S T ABV . TYP. AT (N) FTG TO (E) FTG. 4x44x4 4x4 4x4 4x44x4 MST 4 8 4x4 4x44x4 6x6HDU 8 6x6 HDU 8 6x6HDU 8 6x6 HDU8 5.25x11.875 PSL (E) 12" WIDE CONT. FTG., TO REMAIN, TYP. CF1.0 AT STAIR LANDING AND WALL CONNECTION BELOW SIM. 4X4 w/ MST36 @ HDR TO COL. @ BM. TO DBL STUD. W/ MSTA36 SIM. TYP. @ POST TO BM "HU " HAN G E R 4x44x4 CF1.0 SIM. SIM. SIM. 3 3 DATESUBMITTAL 12/30/2024PLAN CHECK SUBMITTAL 03/03/2025PC SUBMITTAL #2 04/28/2025PC SUBMITTAL #3 UN I T 3 74 0 W S t . A N D R E W S P L A C E SA N T A A N A CA 9 2 7 0 7 - 2 6 2 1 3 S2.0 2 36912SCALE: 1"=1'-0" 1SECTION AT EXTERIOR FOOTING SCALE: 1"=1'-0" SCALE: 1"=1'-0" SCALE: 1"=1'-0" 5SCALE: 1"=1'-0" SECTION AT FOOTING SCALE: 1"=1'-0"SCALE: 1"=1'-0" PLAN VIEW SECTION A-A 4SCALE: 1"=1'-0" Sheet 03/03/25Date Scale PROJECT: Job Drawn M.G. Sheet Title BYREVISIONS AS SHOWN DE T A C H E D A C C E S S O R Y D W E L L I N G U N I T DATESUBMITTAL 12/30/2024PLAN CHECK SUBMITTAL 03/03/2025PC SUBMITTAL #2 04/28/2025PC SUBMITTAL #3 PC #3 (N) FOOTING CONNECTION AT (E) FOOTING 6" MIN. EMB. HOLDOWN DETAIL AT NEW FOOTING STRUCTURAL DETAILS SECTION AT NON-LOAD BEARING WALL SAND SLAB 2X STUDS @ 16" O.C. PROVIDE HILTI X-CP 72 SHOT PIN W/ .145 DIA. SHANK @ 16" O.C., TYP. (ICC-ES ESR 2379) INTERIOR CONC. SLAB ON GRADE INTERIOR NON-LOAD BEARING WALL, TYP. REFER TO ARCH. DWG'S. FOR GYP. BOARD & FINISH STAIR STRINGER FOOTING POST CONNECTION AT PAD FOOTING EQ . EQ . 6" MIN. EMBED.3"3" 3 3 UN I T 74 0 W S t . A N D R E W S P L A C E SA N T A A N A CA 9 2 7 0 7 - 2 6 2 1 S2.1 14 15182124SCALE: 1"=1'-0" 13 SCALE: 1"=1'-0" SCALE: 1"=1'-0" SCALE: 1"=1'-0" 20NOT TO SCALE SCALE: 1"=1'-0"SCALE: 1"=1'-0" Sheet 03/03/25Date Scale PROJECT: Job Drawn M.G. Sheet Title BYREVISIONS AS SHOWN DE T A C H E D A C C E S S O R Y D W E L L I N G U N I T DATESUBMITTAL 12/30/2024PLAN CHECK SUBMITTAL 03/03/2025PC SUBMITTAL #2 22SCALE: 1"=1'-0" 23SCALE: 1"=1'-0" ASECTION@INTERIOR WALL BSECTION@EXTERIOR WALL HOLDOWN AT EXISTING FOOTING CONNECTION AT STAIR STRINGER GUARD CONNECTION FRAMING CONNECTIONS SHEAR TRANSFER AT EXISTING FOOTING FRAMING CONNECTION AT STAIRS CONTINUOUS POST PER PLAN BEAM / JOIST PER PLAN A35 SIMPSON HUCQ HANGER PLAN VIEW A SIDE VIEW B BM TO POST FACE MOUNT CONN. SECTION PARALLEL TO JOISTS HOLDOWN TYPE HOLDOWN MAX. ALLOW. LOAD PULL TEST AT 1.6 X ALLOW. LOAD EMBED. DEPTH 'D' 75% CAPACITY FRAMING CONNECTION WOOD GUARD RAIL POST CONNECTION UN I T 74 0 W S t . A N D R E W S P L A C E SA N T A A N A CA 9 2 7 0 7 - 2 6 2 1 S3.0 2 369SCALE: 1"=1'-0" 17 11 SCALE: 1"=1'-0" SCALE: 1"=1'-0"SCALE: 1"=1'-0"4SCALE: 1"=1'-0" SHEAR TRANSFER AT RAKE END SHEAR TRANSFERAT EAVES SCALE: 1"=1'-0" SCALE: 1"=1'-0"12SCALE: 1"=1'-0" Sheet 03/03/25Date Scale PROJECT: Job Drawn M.G. Sheet Title BYREVISIONS AS SHOWN DE T A C H E D A C C E S S O R Y D W E L L I N G U N I T 20 0 2 S P A R T O N S T . SA N T A A N A CA 9 2 7 0 7 - 2 6 2 1 DATESUBMITTAL 12/30/2024PLAN CHECK SUBMITTAL 03/03/2025PC SUBMITTAL #2 10SCALE: 1"=1'-0" WOOD BEAM(S) AT WOOD POST 5SCALE: 1"=1'-0" SHEAR TRANSFER AT FLOOR LEVELSHEAR TRANSFER AT FLOOR LEVEL SECTION AT 'MST' HOLDOWN HOLDOWN SCHEDULE HOLDOWN TYPE CLEAR SPAN FASTENERS (ESR-2105)MAX. ALLOW. TENSION LOAD STRUCTURAL DETAILS CONNECTION AT RIDGE BEAM 8SCALE: 1"=1'-0" WOOD BEAM TO HDR CONNECTION FRAMING CONNECTIONPOST TO BEAM CONNECTION FRAMING CONNECTION MST @ BEAM TO COLUMN UN I T 3 FOUNDATION CONCRETE WOODREINFORCING STEELGENERAL G E N E R A L S T R U C T U R A L N O T E S STRUCTURAL DESIGN CRITERIA SHEET INDEX AND STRUCTURAL TESTSPECIAL INSPECTION PROGRAM ADDINATIONAL NOTES Sheet 03/03/25Date Scale PROJECT: Job Drawn M.G. Sheet Title BYREVISIONS AS SHOWN DE T A C H E D A C C E S S O R Y D W E L L I N G U N I T DATESUBMITTAL 12/30/2024PLAN CHECK SUBMITTAL 03/03/2025PC SUBMITTAL #2 EPOXY ANCHORS STRUCTURAL OBSERVATION SN1 GENERAL NOTES UN I T 74 0 W S t . A N D R E W S P L A C E SA N T A A N A CA 9 2 7 0 7 - 2 6 2 1 STRUCTURAL OBSERVATION CONT' A PROJECT FOR: PROJECT ADDRESS: SHEET TITLE DATE: SHEET: PROJECT INFO PROJECT # DRAWN BY: CHECKED BY: SCALE: AS SHOWN AT T A C H E D A C C E S S O R Y DW E L L I N G U N I T 74 0 W S t . A N D R E W S P L A C E SA N T A A N A CA 9 2 7 0 7 - 2 6 2 1 REVISED BY: REVISIONS: DATE:BY: PROJECT: REVISED BY: DESIGNER: YMMAR BROWN ENGINEER: VISAL TE G GREEN NOTES 10/16/2024 YB A PROJECT FOR: PROJECT ADDRESS: SHEET TITLE DATE: SHEET: PROJECT INFO PROJECT # DRAWN BY: CHECKED BY: SCALE: AS SHOWN AT T A C H E D A C C E S S O R Y DW E L L I N G U N I T 74 0 W S t . A N D R E W S P L A C E SA N T A A N A CA 9 2 7 0 7 - 2 6 2 1 REVISED BY: REVISIONS: DATE:BY: PROJECT: REVISED BY: DESIGNER: YMMAR BROWN ENGINEER: VISAL TE GREEN NOTES G-1 10/16/2024 YB A PROJECT FOR: PROJECT ADDRESS: SHEET TITLE DATE: SHEET: PROJECT INFO PROJECT # DRAWN BY: CHECKED BY: SCALE: AS SHOWN AT T A C H E D A C C E S S O R Y DW E L L I N G U N I T 74 0 W S t . A N D R E W S P L A C E SA N T A A N A CA 9 2 7 0 7 - 2 6 2 1 REVISED BY: REVISIONS: DATE:BY: PROJECT: REVISED BY: DESIGNER: YMMAR BROWN ENGINEER: VISAL TE G-2 GREEN NOTES 10/16/2024 YB T-1 Roben Mardirosian, P.E. 10540 Jardine Ave. Sunland, CA 91040 Tel: (818) 484-0495 Email: roben@armenengineers.com 74 0 W S T . A N D R E W S P L A C E SA N T A A N A , C A 9 2 7 0 7 ( A D U ) TI T L E - 2 4 R E P O R T DATE: 02/24/2025 T-2 Roben Mardirosian, P.E. 10540 Jardine Ave. Sunland, CA 91040 Tel: (818) 484-0495 Email: roben@armenengineers.com 74 0 W S T . A N D R E W S P L A C E SA N T A A N A , C A 9 2 7 0 7 ( A D U ) TI T L E - 2 4 R E P O R T DATE: 02/24/2025 Page 330 2022 Building Energy Efficiency Standards Dwelling Unit Floor Area (ft2) >1500 >1000 - 1500 750 - 1000 <750 Table 150.0-G Kitchen Range Hood Airflow Rates (cfm) and ASTM E3087 Capture Efficiency (CE) Ratings According to Dwelling Unit Floor Area and Kitchen Range Fuel Type Hood Over Electric Range 50% CE or 110 cfm 50% CE or 110 cfm 55% CE or 130 cfm 65% CE or 160 cfm Hood Over Natural Gas Range 70% CE or 180 cfm 80% CE or 250 cfm 85% CE or 280 cfm 85% CE or 280 cfm Table 150.0-H Prescriptive Ventilation System Duct Sizing [ASHRAE 62.2:Table 5-3] Fan Airflow Rating, cfm at minimum static pressuref 0.25 in. water (L/s at minimum 62.5 Pa) Minimum Duct Diameter, in. (mm) a,b For Rigid duct Minimum Duct Diameter, in. (mm) a,b For Flex duct c ≤50 (25) 4 e (100) 4 (100) ≤80 (40) 5 (125) 5 (125) ≤100 (50) 5 (125) 6 (150) ≤125 (60) 6 (150) 6 (150) ≤150 (70) 6 (150) 7 (150) ≤175 (85) 7 (180) 7 (180) ≤200 (95) 7 (180) 8 (205) ≤250 (120) 8 (205) 8 (205) ≤350 (165) 9 (230) 9 (230) ≤400 (190) 10 (255) 10 (255) ≤450 (210) 10 (255) NP ≤700 (330) 12 (305) NP ≤800 (380) 12 d (305) NP Footnotes for Table 150.0-H: a. For noncircular ducts, calculate the diameter as four times the cross-sectional area divided by the perimeter. b. NP = application of the prescriptive table is not permitted for this scenario. c. Use of this table for verification of flex duct systems requires flex duct to be fully extended and any flex duct elbows to have a minimum bend radius to duct diameter ratio of 1.0. d. For this scenario, use of elbows is not permitted. e. For this scenario, 4 in. (100 mm) oval duct shall be permitted, provided the minor axis of the oval is greater than or equal to 3 in. (75 mm) f. When a vented range hood utilizes a capture efficiency rating to demonstrate compliance with 150.0(o)1Giiib, a static pressure greater than or equal to 0.25 in. of water at the rating point shall not be required, and the airflow listed in the approved directory corresponding to the compliant capture efficiency rating point shall be applied to Table 150.0-H for determining compliance. Note: Authority: Sections 25213, 25218, 25218.5, 25402 and 25402.1, Public Resources Code. Reference: Sections 25007, 25008, 25218.5, 25310, 25402, 25402.1, 25402.4, 25402.5, 25402.8, and 25943, Public Resources Code. SECTION 150.0 – MANDATORY FEATURES AND DEVICES T-3 Roben Mardirosian, P.E. 10540 Jardine Ave. Sunland, CA 91040 Tel: (818) 484-0495 Email: roben@armenengineers.com 74 0 W S T . A N D R E W S P L A C E SA N T A A N A , C A 9 2 7 0 7 ( A D U ) TI T L E - 2 4 R E P O R T DATE: 02/24/2025 Panasonic Whisper Ceiling Fan FV-0511VQ1 Static Pressure in inches w.g. Air Volume (CFM) Noise (sones) Ventilation Fan Characteristics (HVI Certified data ) Power Consumption (watts) Energy Efficiency (CFM/Watt) Speed (RPM) Current (amps) Power Rating (V/Hz) ENERGY STAR rated 0.1 110 <0.3 10.6 10.6 957 0.18 120/60 YES 0.25 111 0.9 16.4 6.9 1239 0.26 4" 0.1 50 <0.3 4 12.5 756 0.07 120/60 YES 0.25 53 0.4 7.2 7.4 1093 0.13 0.1 80 <0.3 5.9 13.6 821 0.11 120/60 YES 0.25 83 0.6 10.8 7.7 1172 0.18 4"4" T-4 Roben Mardirosian, P.E. 10540 Jardine Ave. Sunland, CA 91040 Tel: (818) 484-0495 Email: roben@armenengineers.com 74 0 W S T . A N D R E W S P L A C E SA N T A A N A , C A 9 2 7 0 7 ( A D U ) TI T L E - 2 4 R E P O R T DATE: 02/24/2025 STRUCTURAL CALCULATIONS PROJECT: 2-STORY ADU FOR EXISTING GARAGE PREPARED BY: VISAL TE, P.E. 04/28/2025 (PER 2022 CBC) UN I T 740 W st. Andrews Place Santa Ana, CA 92707 PREPARED CHECKED BY ~(} c /~}~C ~ ~;', L' ~77E' ~ ~at~ ~ , ~ 1. ` L ~1 ' `i " ,2. t c- r~~'~t ~~ e~ ~K 6 ~ L r~ c `'~_ ~csC_ ~. ~:1 ~~_.__~.' ~'; ~b ~c (. 2 ~ Psi . F omI . ~1 ~ ~-~'~~s 1 h~~~~~L~ iav,1~ C~,~s,.,._: r ~51 ~~~ ~~ 12.;" v `i ~~ f S~ ~._. ~~ ~~_ ~['y .r, ~~ . ti 0 a 0 ('J O l.. (` ~ { s ~~Cn l /~ <= v ,+ r~ ~ l~ ~~.~ J ~~~ i . ~ ~' I.~Cn~~ ~~Ucl «~.y.. ~r (~ !SEA (~•~ 1.{~ ~s-t`. .2Y~1C~1~`= ~-~ 1 `~ ~~~ ~1 ~ ~~ ~~:~1 ~, ~,,~, .. ~"' ~'~; ~,~ c. t? . ~ ~ ~ - ~'~ Esc - ~... ~` ' ~ 1~ ~i . A `may • p. . USGS web services were down for some period of time and as a result this tool wasn't operational, resulting in timeout error. USGS web services are now operational so this tool should work as expected. 2002 Parton St 2002 S Parton St, Santa Ana, CA 92707, USA Latitude, Longitude: 33.7223723, -117.874213 Date 10/16/2024, 1:13:57 PM Design Code Reference Document ASCE7-16 Risk Category II Site Class D - Default (See Section 11.4.3) Type Value Description SS 1.285 MCER ground motion. (for 0.2 second period) S1 0.46 MCER ground motion. (for 1.0s period) SMS 1.542 Site-modified spectral acceleration value SM1 null -See Section 11.4.8 Site-modified spectral acceleration value SDS 1.028 Numeric seismic design value at 0.2 second SA SD1 null -See Section 11.4.8 Numeric seismic design value at 1.0 second SA Type Value Description SDC null -See Section 11.4.8 Seismic design category Fa 1.2 Site amplification factor at 0.2 second Fv null -See Section 11.4.8 Site amplification factor at 1.0 second PGA 0.545 MCEG peak ground acceleration FPGA 1.2 Site amplification factor at PGA PGAM 0.654 Site modified peak ground acceleration TL 8 Long-period transition period in seconds SsRT 1.285 Probabilistic risk-targeted ground motion. (0.2 second) SsUH 1.384 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration SsD 1.645 Factored deterministic acceleration value. (0.2 second) S1RT 0.46 Probabilistic risk-targeted ground motion. (1.0 second) S1UH 0.496 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration. S1D 0.6 Factored deterministic acceleration value. (1.0 second) 10/16/24, 1:14 PM U.S. Seismic Design Maps https://www.seismicmaps.org 1/3 PROJECT : PAGE : CLIENT : DESIGN BY : JOB NO. : DATE : REVIEW BY : Determine Base Shear (Derived from ASCE 7-16 Sec. 12.8 & Supplement 2) V =MAX{ MIN [ SD1I / (RT) , SDS I / R ] , MAX(0.044SDSI , 0.01) , 0.5S1 I / R } W = MAX{ MIN[ 0.39W , 0.15W ] , 0.04W , 0.00W }^ = 0.20 W, (SD)(for S1 ≥ 0.6 g only) =0.14 W, (ASD) =5.49 kips Where SDS =1.285 (ASCE 7-16 Sec 11.4.4) SD1 =Null (ASCE 7-16 Sec 11.4.8) S1 =0.46 (ASCE 7-16 Sec 11.4.1) R =6.5 (ASCE 7-16 Tab 12.2-1) I =1 (ASCE 7-16 Tab 11.5-1) Ct =0.02 (ASCE 7-16 Tab 12.8-2) hn =19.9 ft x =0.75 (ASCE 7-16 Tab 12.8-2) T = Ct (hn)x =0.189 sec, (ASCE 7-16 Sec 12.8.2.1) Calculate Vertical Distribution of Forces & Allowable Elastic Drift (ASCE 7-16, Sec 12.8.3 & 12.8.6) Level Wx hx hx k Wxhx k Fx , ASD (12.8-11)dxe,allowable, ASD Roof 16.3 7.833 7.8 128 2.0 ( 0.12 Wx )0.5 2ND 22.6 9.67 9.7 219 3.5 ( 0.15 Wx )0.5 38.9 346 5.5 Where k = 1 for T <= 0.5 k = 0.5 T + 0.75 for T @ (0.5 , 2.5)Cd =4 ,(ASCE 7-16 Tab 12.2-1) k = 2 for T >= 2.5 Da =0.02 hsx, (ASCE 7-16 Tab 12.12-1) Calculate Diaphragm Forces (ASCE 7-10, Sec 12.10.1.1) Level Wx SWx Fx SFx Roof 16.3 16.3 2.0 2.0 2.8 ( 0.17 Wx ) 2ND 22.6 38.9 3.5 5.5 3.9 ( 0.17 Wx ) 38.9 603.4 Where Fmin = 0.2 SDS I W x / 1.5 , ASD Fmax = 0.4 SDS I W x / 1.5 , ASD Fpx , ASD, (12.10-1) VISAL TE dxe,allowable, ASD = Da I / (1.4 Cd), (ASCE 7-16 Sec 12.8.6) 2002 Parton St, Santa Ana, CA 92707 Two Story Seismic Analysis CBC 2022 PROJECT : PAGE : CLIENT : DESIGN BY : JOB NO. : DATE : REVIEW BY : INPUT DATA Exposure category (B, C or D)C Importance factor, pg 77, (0.87, 1.0 or 1.15)I =1.00 Category II Basic wind speed (IBC Tab 1609.3.1V3S)V = 110 mph Topographic factor (Sec.6.5.7.2, pg 26 & 45)Kzt =1 Flat Building height to eave he = 16.5 ft Building height to ridge hr = 19.9 ft Building length L =23 ft Building width B =21.75 ft A = 500 ft2 DESIGN SUMMARY Max horizontal force normal to building length, L, face =8.59 kips Max horizontal force normal to building length, B, face =7.19 kips Max total horizontal torsional load =27.39 ft-kips Max total upward force =9.66 kips ANALYSIS Velocity pressure qh = 0.00256 Kh Kzt Kd V2 I =23.22 psf where: qh = velocity pressure at mean roof height, h. (Eq. 6-15, page 27) Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 6-3, Case 1,pg 79)= 0.88 Kd = wind directionality factor. (Tab. 6-4, for building, page 80)= 0.85 h = mean roof height =18.20 ft < 60 ft, [Satisfactory] < Min (L, B), [Satisfactory] Design pressures for MWFRS 2002 S Parton St, Santa Ana, CA 92707 Wind Analysis for Low-rise Building, Based on ASCE 7-10 Effective area of components (or Solar Panel area) Visal Te Design pressures for MWFRS p = qh [(G Cpf )-(G Cpi )] where: p = pressure in appropriate zone. (Eq. 6-18, page 28). pmin =10 psf (Sec. 6.1.4.1 & 6.1.4.2) G Cp f = product of gust effect factor and external pressure coefficient, see table below. (Fig. 6-10, page 53 & 54) G Cp i = product of gust effect factor and internal pressure coefficient.(Fig. 6-5, Enclosed Building, page 47) =0.18 or -0.18 a = width of edge strips, Fig 6-10, note 9, page 54, MAX[ MIN(0.1B, 0.1L, 0.4h), MIN(0.04B, 0.04L), 3] =3.00 ft Net Pressures (psf), Basic Load Cases Net Pressures (psf), Torsional Load Cases 17.36 0.00 17.36 (+GCp i ) (-GCp i ) (+GCp i ) (-GCp i ) (+GCp i ) (-GCp i ) 1 0.51 7.60 15.96 0.40 5.11 13.47 1T 0.51 1.90 3.99 2 -0.69 -20.20 -11.84 -0.69 -20.20 -11.84 2T -0.69 -5.05 -2.96 3 -0.46 -14.88 -6.52 -0.37 -12.77 -4.41 3T -0.46 -3.72 -1.63 4 -0.41 -13.59 -5.23 -0.29 -10.91 -2.55 4T -0.41 -3.40 -1.31 1E 0.77 13.62 21.98 0.61 9.99 18.35 0.00 2E -1.07 -29.03 -20.67 -1.07 -29.03 -20.67 3E -0.66 -19.55 -11.19 -0.53 -16.49 -8.13 (+GCp i ) (-GCp i ) 4E -0.60 -18.18 -9.82 -0.43 -14.17 -5.81 1T 0.40 1.28 3.37 5 -0.45 -14.63 -6.27 -0.45 -14.63 -6.27 2T -0.69 -5.05 -2.96 6 -0.45 -14.63 -6.27 -0.45 -14.63 -6.27 3T -0.37 -3.19 -1.10 4T -0.29 -2.73 -0.64 Net Pressure withG Cp f Surface Roof angle q = Net Pressure withG Cp f Surface Roof angle q = G Cp f Roof angle q = Surface G Cp f Net Pressure with Roof angle q = Net Pressure with Basic Load Cases in Transverse Direction Basic Load Cases in Longitudinal Direction Area Area (ft2)(+GCp i ) (-GCp i )(ft2)(+GCp i ) (-GCp i ) 1 281 2.13 4.48 1 291 1.49 3.92 2 194 -3.91 -2.29 2 190 -3.83 -2.25 3 194 -2.88 -1.26 3 190 -2.42 -0.84 4 281 -3.81 -1.47 4 291 -3.18 -0.74 1E 99 1.35 2.18 1E 105 1.04 1.92 2E 68 -1.98 -1.41 2E 72 -2.10 -1.49 3E 68 -1.34 -0.77 3E 72 -1.19 -0.59 4E 99 -1.80 -0.97 4E 105 -1.48 -0.61 Horiz.8.59 8.59 Horiz.7.19 7.19 Vert.-9.66 -5.47 Vert.-9.11 -4.93 Min. wind Horiz.4.58 4.58 Min. wind Horiz.3.96 3.96 Sec. 6.1.4.1 Vert.-5.00 -5.00 Sec. 6.1.4.1 Vert.-5.00 -5.00 Torsional Load Cases in Transverse Direction Torsional Load Cases in Longitudinal Direction Area Area (ft2)(+GCp i ) (-GCp i ) (+GCp i ) (-GCp i )(ft2)(+GCp i ) (-GCp i ) (+GCp i ) (-GCp i ) 1 91 0.69 1.45 3 6 1 93 0.48 1.26 1 3 2 63 -1.27 -0.74 -2 -1 2 117 -2.37 -1.39 4 2 3 63 -0.93 -0.41 1 1 3 117 -1.50 -0.52 -3 -1 4 91 -1.23 -0.47 5 2 4 93 -1.02 -0.24 2 1 1E 99 1.35 2.18 11 18 1E 105 1.04 1.92 8 15 2E 68 -1.98 -1.41 -5 -4 2E 72 -2.10 -1.49 4 3 3E 68 -1.34 -0.77 3 2 3E 72 -1.19 -0.59 -2 -1 4E 99 -1.80 -0.97 15 8 4E 105 -1.48 -0.61 12 5 1T 190 0.36 0.76 -2 -4 1T 198 0.25 0.67 -1 -4 2T 131 -0.66 -0.39 1 1 2T 190 -0.96 -0.56 -3 -2 3T 131 -0.49 -0.21 -1 0 3T 190 -0.61 -0.21 2 1 4T 190 -0.64 -0.25 -4 -1 4T 198 -0.54 -0.13 -3 -1 27 27 21.0 21.0 S Pressure (k) with Pressure (k) with Torsion (ft-k) Pressure (k) with Surface Total Horiz. Torsional Load, MT Surface Surface S Torsion (ft-k) Total Horiz. Torsional Load, MT Surface Pressure (k) with Design pressures for components and cladding p = qh[ (G Cp) - (G Cpi)] where:p = pressure on component. (Eq. 6-22, pg 28) pmin = 10.00 psf (Sec. 6.1.4.2, pg 21) G Cp = external pressure coefficient. see table below. (Fig. 6-11, page 55~58) Effective Area (ft2) GCP - GCP GCP - GCP GCP - GCP GCP - GCP GCP - GCP Comp.500 0.30 -0.80 0.30 -1.20 0.30 -2.00 0.70 -0.80 0.70 -0.80 Positive Negative Positive Negative Positive Negative Positive Negative Positive Negative 11.15 -22.76 11.15 -32.05 11.15 -50.63 20.44 -22.76 20.44 -22.76 Note:If the effective area is roof Solar Panel area, the only zone 1, 2 , or 3 apply. Zone 4Zone 2 Zone 3 Zone 1 Zone 2 Comp. & Cladding Zone 1 ( psf ) Zone 4 Zone 5Zone 3 Zone 5 Pressure LATERAL (SEISMIC) (ROOF LEVEL) Wroof= ( 594 SF) (10 PSF+5 PSF) + 1/2 ( 7.83' HEIGHT) ( 89.5' )(15psf)+ 1/2 ( 7.83' HEIGHT) (69.33') ( 8 PSF) ROOF+CEILING EXT. INTER. WALL WALL Wroof = 16.3K (2ND FLOOR) W2ND FLOOR = ( 9.67' HEIGHT) ( 89.5' ) (15 PSF) + ( 500 SF) (14 PSF) + ( 9.67' HEIGHT) (34.5') (8 PSF) W2ND FLOOR = 22.6K SEE CALCULATE EXCEL SHEET FOR CALCULATED STORY FORCE Fx-roof = ( 2.0 kips ) Fx-2nd floor = 3.5 kips (2ND FLOOR) V shear= 2.0 kips (1ST FLOOR) V Shear = 2.0+3.5 = 5.5k WIND -ANALYSIS 2ND FLOOR Vshear = 21.98 psf x ( 4' ) x (23.0 ') = 2.02k 1ST FLOOR Vshear = 21.98 psf x ( 9' ) x (23.0') = 4.55k (ASD) 2ND FLOOR Vshear = 0.6w = 0.6 ( 2.02k )= 1.21k < 2.0k (ASD 1ST FLOOR Vshear = 0.6w = 0.6 (4.55k) = 2.73k < 5.5k :. SEISMIC GOVERNS FOUNDATION PLAN 2ND FLOOR FRAMING PLAN " O.C. KEY PLAN FOR SHEARWALL AND HOLDOWN DESIGN. SEE NEXT SHEET. 1st FLOOR SHEARWALL 2nd FLOOR SHEARWALL B C D F H 1 7 86 1 7 86 H B 1 2 3 4 5 6 7 8 9 10 LANDING 1 L=13'-8" 1 L=18'-6" 1 L=4'-4" 3 L= 3 ' - 5 " 1 L= 1 3 ' - 0 " 3 L= 3 ' - 5 " 23'-0" 23'-0" 16'-6"3'-0"3'-6" B C D E H 1 2 3 4 5 7 8 A 1 4 7 8 H G B A F 5 6 7 8 9 10 11 12 13 15 16 17 14 LANDING LANDING HDR. HDR. HDR. R.R.-1R.R.-1 1 L=6'-1" 1 L= 1 3 ' - 0 " 1 L= 5 ' - 0 " R. B M . - 1 1 L=17'-8" LO W R O O F R. R . - 1 4x8 3x LEDGER HDR. 1 L=4'-4" 1 L=4'-4" 23'-0" 21 ' - 9 " 23'-0" 7 1 2 3 4 5 NO. PANEL WALL SHEAR W/ 10d COMMON 1/2" STRUCT. 1 PLYWD./OSB PANEL OR 16d 5/8" x 9" LAG SCREWS SIMP. SDS 1/4"Ø x 6" OR FLOOR PLATE FASTERNERS OR 16d 5/8" x 9" LAG SCREWS SIMP. SDS 1/4"Ø x 6" OR FLOOR PLATE FASTERNERS FACE SIDE ONE SIDE ONE SIDE ONE SIDE ONE SIDES TWO SIDES TWO SIDES TWO NAILING @ PANEL EDGE FIELD MEMBER EDGE FASTERNERS SIZE SPACING PLATE SIZE EXTERIOR TYPE SPACING TYPE SPACING INTERIOR FASTERNERS SIZE SPACING 5/8"Ø x 3/4"Ø ANCHORS ANCHOR BOLTS @ SILL PLATE (PLF) SHEAR ALLOWABLE (PLF) SHEAR ALLOWABLE 6" 4" 4" 4" 6" 4" 4" 6" 8" 3" 8" 8" 8" SDPWS-15SDPWS-15 STAGG. 3" STAGG. 2" STAGG. 3" STAGG. 2" 12" 12" 12" 12" 12" 12" 12" MIN. 3x MIN. 3x MIN. 3x MIN. 3x MIN. 3x MIN. 4x MIN. 4x 16d SDS 1/4"Ø SDS 1/4"Ø SDS 1/4"Ø SDS 1/4"Ø LAG 5/8"Ø LAG 5/8"Ø MIN. 2x MIN. 3x MIN. 3x MIN. 3x MIN. 3x MIN. 3x MIN. 3x LTP4 LTP4 LTP4 LTP4 LTP4 A35 A35 16" 16" 2 SIDES 8" 2 SIDES 8" A35 A35 A35 A35 A35 A35 A35 8" 8" 8" 16" 16" 2 SIDES 8" 2 SIDES 8" 5/8" Ø 5/8" Ø 5/8" Ø 5/8" Ø 5/8" Ø 3/4" Ø 7/8" Ø FOR 2x 32" 32" 16" 16" 16" 16" 16" MIN. 2x MIN. 3x MIN. 3x MIN. 3x MIN. 3x MIN. 3x MIN. 3x 340 510 665 870 1020 1330 1740 475 715 930 1217 1430 1860 2435 SHEAR PANEL SCHEDULE SILL PLT. SIZE (SEISMIC)(WIND) 6 NOTES: FLOOR SHEATHING, TYP. U.N.O. PROVIDE MINIMUM 3 IN. PENETRATION INTO MEMBERS BELOW 10. USE 3x AND TREATED SILL PLATE AT CONCRETE SURFACES,TYP.9. ALL NAILS SHALL BE COMMON NAILS, TYP.8. A MINIMUM OF 5d CONCRETE COVER AND 10" MIN. EMBEDMENT. ALL ANCHOR BOLTS AT EDGE OF CONCRETE SHALL HAVE7. ENDS AND EDGES. AND A MINIMUM 1/2" EDGE NAILING DISTANCES AT PANEL OF THE CONNECTING MEMBER FOR SHEAR PANEL PANEL EDGE AND AT LEAST 3/8" FROM THE EDGE NAILS SHALL BE PLACED AT LEAST 3/8" FROM6. USE PLT. 1/4"x3" SQ W/ 5/8" & 3/4" DIA. A.B.5. MORE THAN 1-5/8". COMMON NAILS ARE SPACED 3" O.C. PENETRATE FRAMING EDGES. WHEN NAIL SPACING IS 2" O.C. OR WHEN 10d NAIL SHALL BE STAGGERED IN TWO LINES ALONG PANEL WALL FRAMING TO BE MIN. 3x MEMBER AT PANEL EDGES.4. 3. FOR HOLD DOWN ANCHOR (HD) SEE PLAN & DETIAL PLYWOOD WITH MIN. 5-PLY. ALL PLYWOOD SHEAR PANELS TO BE 1/2" STRUC I2. SEE FRAMING PLANS FOR LOCATION OF SHEAR PANELS1. 2 1/2" MIN. 1/2" MIN. 2" TO 3" SPACING NAILING PATTERN AT PANEL JOINT (FOR 2" AND 3" NAIL SPACINGS) PLYWD. PANEL JOINT 3x MIN. @ Shearwall Design 2nd Floor Shear walls (FT) Shear Cap. (lb/ft) Along Grid line B : L = 14.42 340 Along Grid line H: L= 20.0 340 Along Grid line 1 : L = 21.75 340 Along Grid line 8: L= 13.0 340 1st Floor Shear walls (FT)Shear Cap. (lb/ft) Along Grid line B : L = 13.67+4.33 340 Along Grid line H: L =23 340 Along Grid line 1 : L=3.42+3.42 665 Along Grid line 8: L=13 340 Hold-Down design 2nd Floor Shea wall Height (ft)Uplift (lbs) Net Uplist Hold-down Hold-down Capacity (lbs) Along Grid line B : 7.8 950 950 MST48 3960 Along Grid line H: 7.8 685 685 MST48 3960 Along Grid line 1 : 7.8 630 630 MST48 3960 Along Grid line 8: 7.8 1054 1054 MST48 3960 1st Floor Along Grid line B : 9.7 1880 1880 HDU2-SDS2.5 2306 Along Grid line H: 9.7 1472 1472 HDU2-SDS2.5 2306 Along Grid line 1 : 9.7 4948 4948 HDU8-SDS2.5 5903 Along Grid line 8: 9.7 2603 2603 HDU4-SDS2.5 3424 Shearwall No. 1 1 1 Unit Shear (lb/ft) 121 80 135 188 2691 1941 5123 1 152 Unit Shear (lb/ft) Shearwall No. 1211 Shear (lbs) 1750 Shear (lbs) 3500 3500 3500 269 512 Unit Shear (lb/ft) 1750 1750 1750 1 88 801 1351 Shearwall No. 194 3500 152 1 1 1 (0.6-0.14Sds)D 3 Wood Beam LIC# : KW-06016542, Build:20.24.06.04 (c) ENERCALC INC 1983-2023 DESCRIPTION:Roof Rafter Project File: 2002 Parton ST.ec6 Project Title:2002 Parton St Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 20 , ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.0150, Lr = 0.020 ksf, Tributary Width = 1.330 ft, (Roof) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.715: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 5.600ft 45.27 psi= = 1,681.88psi 2x6Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 2x6 Maximum Shear Stress Ratio 0.201 : 1 10.750 ft= = 1,202.68psi Maximum Deflection 0 <360 259 Ratio =0 <240 Max Downward Transient Deflection 0.285 in 472 Ratio = >=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.517 in Ratio = >=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 11.20 ft 1 0.447 0.126 0.90 1.300 1.151.00 1.00 0.34 540.9 1,211.0 0.11 162.01.00 20.41.00 1.00+D+Lr 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 11.20 ft 1 0.715 0.201 1.25 1.300 1.151.00 1.00 0.76 1,202.7 1,681.9 0.25 225.01.00 45.31.00 1.00+D+0.750Lr 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 11.20 ft 1 0.617 0.174 1.25 1.300 1.151.00 1.00 0.65 1,037.2 1,681.9 0.21 225.01.00 39.01.00 1.00+0.60D 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 11.20 ft 1 0.151 0.042 1.60 1.300 1.151.00 1.00 0.20 324.5 2,152.8 0.07 288.01.00 12.21.00 . 22 Wood Beam LIC# : KW-06016542, Build:20.24.06.04 (c) ENERCALC INC 1983-2023 DESCRIPTION:Roof Rafter Project File: 2002 Parton ST.ec6 Project Title:2002 Parton St Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.5173 5.641 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.271 0.271 Max Upward from Load Combinations 0.271 0.271 Max Upward from Load Cases 0.149 0.149 D Only 0.122 0.122 +D+Lr 0.271 0.271 +D+0.750Lr 0.233 0.233 +0.60D 0.073 0.073 Lr Only 0.149 0.149 Wood Beam LIC# : KW-06016542, Build:20.24.06.04 (c) ENERCALC INC 1983-2023 DESCRIPTION:RIDGE BEAM [R.BM-1] Project File: 2002 Parton ST.ec6 Project Title:2002 Parton St Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 20 , ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist Parallam PSL 2.0E 2,900.0 2,900.0 2,900.0 750.0 2,000.0 1,016.54 290.0 2,025.0 45.070 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.010, Lr = 0.020 ksf, Tributary Width = 11.10 ft, (Floor) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.521: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 10.500ft 81.26 psi= = 3,629.22psi 5.25x11.875Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 362.50 psi== Section used for this span 5.25x11.875 Maximum Shear Stress Ratio 0.224 : 1 0.000 ft= = 1,889.86psi Maximum Deflection 0 <360 237 Ratio =0 <180 Max Downward Transient Deflection 0.667 in 377 Ratio = >=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 1.059 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 21.0 ft 1 0.268 0.115 0.90 1.001 1.001.00 1.00 7.19 699.7 2,613.0 1.25 261.01.00 30.11.00 1.00+D+Lr 1.001 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 21.0 ft 1 0.521 0.224 1.25 1.001 1.001.00 1.00 19.43 1,889.9 3,629.2 3.38 362.51.00 81.31.00 1.00+D+0.750Lr 1.001 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 21.0 ft 1 0.439 0.189 1.25 1.001 1.001.00 1.00 16.37 1,592.3 3,629.2 2.85 362.51.00 68.51.00 1.00+0.60D 1.001 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 21.0 ft 1 0.090 0.039 1.60 1.001 1.001.00 1.00 4.32 419.8 4,645.4 0.75 464.01.00 18.11.00 . 22 Wood Beam LIC# : KW-06016542, Build:20.24.06.04 (c) ENERCALC INC 1983-2023 DESCRIPTION:RIDGE BEAM [R.BM-1] Project File: 2002 Parton ST.ec6 Project Title:2002 Parton St Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 1.0589 10.577 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 3.701 3.701 Max Upward from Load Combinations 3.701 3.701 Max Upward from Load Cases 2.331 2.331 D Only 1.370 1.370 +D+Lr 3.701 3.701 +D+0.750Lr 3.119 3.119 +0.60D 0.822 0.822 Lr Only 2.331 2.331 Wood Beam LIC# : KW-06016542, Build:20.24.06.04 (c) ENERCALC INC 1983-2023 DESCRIPTION:[BM-2] Project File: 2002 Parton ST.ec6 Project Title:2002 Parton St Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 20 , ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist Parallam PSL 2.0E 2,900.0 2,900.0 2,900.0 750.0 2,000.0 1,016.54 290.0 2,025.0 45.070 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.0140, L = 0.040 ksf, Tributary Width = 6.750 ft, (Floor) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.455: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 8.000ft 68.73 psi= = 2,920.85psi 5.25x11.25Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 290.00 psi== Section used for this span 5.25x11.25 Maximum Shear Stress Ratio 0.237 : 1 15.066 ft= = 1,328.01psi Maximum Deflection 0 <360 421 Ratio =0 <240 Max Downward Transient Deflection 0.321 in 597 Ratio = >=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.456 in Ratio = >=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only n/a Span: 1 : +D+L n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 16.0 ft 1 0.149 0.078 0.90 1.007 1.001.00 1.00 3.62 391.8 2,628.8 0.80 261.01.00 20.31.00 1.00+D+L 1.007 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.455 0.237 1.00 1.007 1.001.00 1.00 12.26 1,328.0 2,920.8 2.71 290.01.00 68.71.00 1.00+D+0.750L 1.007 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.300 0.156 1.25 1.007 1.001.00 1.00 10.10 1,094.0 3,651.1 2.23 362.51.00 56.61.00 1.00+0.60D 1.007 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.050 0.026 1.60 1.007 1.001.00 1.00 2.17 235.1 4,673.4 0.48 464.01.00 12.21.00 . 22 Wood Beam LIC# : KW-06016542, Build:20.24.06.04 (c) ENERCALC INC 1983-2023 DESCRIPTION:[BM-2] Project File: 2002 Parton ST.ec6 Project Title:2002 Parton St Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+L 1 0.4559 8.058 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 3.064 3.064 Max Upward from Load Combinations 3.064 3.064 Max Upward from Load Cases 2.160 2.160 D Only 0.904 0.904 +D+L 3.064 3.064 +D+0.750L 2.524 2.524 +0.60D 0.542 0.542 L Only 2.160 2.160 Wood Beam LIC# : KW-06016542, Build:20.24.06.04 (c) ENERCALC INC 1983-2023 DESCRIPTION:F.J.-1 Project File: 2002 Parton ST.ec6 Project Title:2002 Parton St Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 20 , ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.0170, L = 0.040 ksf, Tributary Width = 1.330 ft, (Floor) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.404: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 3.750ft 33.94 psi= = 1,242.00psi 2x8Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 180.00 psi== Section used for this span 2x8 Maximum Shear Stress Ratio 0.189 : 1 6.898 ft= = 501.90psi Maximum Deflection 0 <360 1225 Ratio =0 <240 Max Downward Transient Deflection 0.050 in 1800 Ratio = >=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.073 in Ratio = >=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only n/a Span: 1 : +D+L n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 7.50 ft 1 0.143 0.067 0.90 1.200 1.151.00 1.00 0.18 160.3 1,117.8 0.08 162.01.00 10.81.00 1.00+D+L 1.200 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 7.50 ft 1 0.404 0.189 1.00 1.200 1.151.00 1.00 0.55 501.9 1,242.0 0.25 180.01.00 33.91.00 1.00+D+0.750L 1.200 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 7.50 ft 1 0.268 0.125 1.25 1.200 1.151.00 1.00 0.46 416.5 1,552.5 0.20 225.01.00 28.21.00 1.00+0.60D 1.200 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 7.50 ft 1 0.048 0.023 1.60 1.200 1.151.00 1.00 0.11 96.2 1,987.2 0.05 288.01.00 6.51.00 . 22 Wood Beam LIC# : KW-06016542, Build:20.24.06.04 (c) ENERCALC INC 1983-2023 DESCRIPTION:F.J.-1 Project File: 2002 Parton ST.ec6 Project Title:2002 Parton St Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+L 1 0.0734 3.777 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.293 0.293 Max Upward from Load Combinations 0.293 0.293 Max Upward from Load Cases 0.200 0.200 D Only 0.094 0.094 +D+L 0.293 0.293 +D+0.750L 0.243 0.243 +0.60D 0.056 0.056 L Only 0.200 0.200 x20psf ROOF LL =150# Wood Beam LIC# : KW-06016542, Build:20.24.06.04 (c) ENERCALC INC 1983-2023 DESCRIPTION:FLOOR & DECK JOIST (12'-4") Project File: 2002 Parton ST.ec6 Project Title:2002 Parton St Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC , ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase Allowable Stress Design Douglas Fir-South No.2 850.0 850.0 1,350.0 520.0 1,200.0 440.0 180.0 525.0 28.720 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Load for Span Number 1 Uniform Load : D = 0.0140, L = 0.040 ksf, Tributary Width = 1.330 ft, (Floor) Load for Span Number 2 Uniform Load : D = 0.0140, L = 0.060 ksf, Tributary Width = 1.330 ft, (Floor) Point Load : D = 0.0750, Lr = 0.150 k @ 3.330 ft, (Point Load from post abv) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.667: 1 Load Combination +D+0.750Lr+0.750L Span # where maximum occurs Span # 1 Location of maximum on span 9.000ft 52.14 psi= = 1,466.25psi 2x8Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 180.00 psi== Section used for this span 2x8 Maximum Shear Stress Ratio 0.290 : 1 8.397 ft= = 978.47psi Maximum Deflection 1366 >=360 274 Ratio =1267 >=240 Max Downward Transient Deflection 0.206 in 386 Ratio = >=360 Max Upward Transient Deflection -0.079 in Ratio = Max Downward Total Deflection 0.291 in Ratio = >=240 Max Upward Total Deflection -0.085 in fb: Actual F'b fv: Actual F'v Span: 2 : Lr Only Span: 1 : Lr Only Span: 2 : +D+Lr Span: 1 : +D+Lr .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 9.0 ft 1 0.316 0.112 0.90 1.200 1.151.00 1.00 0.37 333.3 1,055.7 0.13 162.01.00 18.21.00 1.00Length = 3.330 ft 2 0.316 0.112 0.90 1.200 1.151.00 1.00 0.37 333.3 1,055.7 0.13 162.01.00 18.21.00 1.00+D+L 1.200 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.629 0.290 1.00 1.200 1.151.00 1.00 0.81 737.4 1,173.0 0.38 180.01.00 52.11.00 1.00Length = 3.330 ft 2 0.629 0.290 1.00 1.200 1.151.00 1.00 0.81 737.4 1,173.0 0.35 180.01.00 52.11.00 2022 Wood Beam LIC# : KW-06016542, Build:20.24.06.04 (c) ENERCALC INC 1983-2023 DESCRIPTION:FLOOR & DECK JOIST (12'-4") Project File: 2002 Parton ST.ec6 Project Title:2002 Parton St Engineer: Project ID: Project Descr: Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00+D+Lr 1.200 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.538 0.173 1.25 1.200 1.151.00 1.00 0.86 789.5 1,466.3 0.28 225.01.00 38.91.00 1.00Length = 3.330 ft 2 0.538 0.173 1.25 1.200 1.151.00 1.00 0.86 789.5 1,466.3 0.28 225.01.00 38.91.00 1.00+D+0.750Lr+0.750L 1.200 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.667 0.250 1.25 1.200 1.151.00 1.00 1.07 978.5 1,466.3 0.41 225.01.00 56.31.00 1.00Length = 3.330 ft 2 0.667 0.250 1.25 1.200 1.151.00 1.00 1.07 978.5 1,466.3 0.41 225.01.00 56.31.00 1.00+D+0.750L 1.200 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.472 0.209 1.15 1.200 1.151.00 1.00 0.70 636.4 1,349.0 0.31 207.01.00 43.31.00 1.00Length = 3.330 ft 2 0.472 0.209 1.15 1.200 1.151.00 1.00 0.70 636.4 1,349.0 0.30 207.01.00 43.31.00 1.00+0.60D 1.200 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 9.0 ft 1 0.107 0.038 1.60 1.200 1.151.00 1.00 0.22 200.0 1,876.8 0.08 288.01.00 10.91.00 1.00Length = 3.330 ft 2 0.107 0.038 1.60 1.200 1.151.00 1.00 0.22 200.0 1,876.8 0.08 288.01.00 10.91.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr+D+L 1 0.0721 3.721 -0.0852 5.682 +D+Lr 2 0.2905 3.330 0.0000 5.682 . Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.243 0.848 Max Upward from Load Combinations 0.243 0.848 Max Upward from Load Cases 0.190 0.554 Max Downward from all Load Conditio -0.055 Max Downward from Load Combinations -0.003 Max Downward from Load Cases (Resis -0.055 D Only 0.053 0.278 +D+L 0.243 0.833 +D+Lr -0.003 0.484 +D+0.750Lr+0.750L 0.154 0.848 +D+0.750L 0.196 0.694 +0.60D 0.032 0.167 Lr Only -0.055 0.206 L Only 0.190 0.554 Wood Beam LIC# : KW-06016542, Build:20.24.06.04 (c) ENERCALC INC 1983-2023 DESCRIPTION:HDR-2 Project File: 2002 Parton ST.ec6 Project Title:2002 Parton St Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 20 , ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist Parallam PSL 2.0E 2,900.0 2,900.0 2,900.0 750.0 2,000.0 1,016.54 290.0 2,025.0 45.070 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.0140, L = 0.040 ksf, Tributary Width = 1.330 ft, (FLOOR) Uniform Load : D = 0.0150 ksf, Tributary Width = 5.60 ft, (WALL) Point Load : D = 0.90, L = 2.160 k @ 4.330 ft, (REACTION BM-2) Point Load : D = 0.90, L = 2.160 k @ 9.0 ft, (REACTION BM-2) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.765: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 8.986 ft 114.35 psi= = 2,920.85 psi 5.25x11.25Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 290.00 psi== Section used for this span 5.25x11.25 Maximum Shear Stress Ratio 0.394 : 1 0.000 ft= = 2,233.85 psi Maximum Deflection 0 <360 273 Ratio =0 <240 Max Downward Transient Deflection 0.398 in 447 Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.650 in Ratio =>=240 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only n/a Span: 1 : +D+L n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 14.833 ft 1 0.327 0.173 0.90 1.007 1.001.00 1.00 7.94 860.2 2,628.8 1.78 261.01.00 45.21.00 1.00+D+L 1.007 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 14.833 ft 1 0.765 0.394 1.00 1.007 1.001.00 1.00 20.62 2,233.9 2,920.8 4.50 290.01.00 114.31.00 1.00+D+0.750L 1.007 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 14.833 ft 1 0.517 0.268 1.25 1.007 1.001.00 1.00 17.44 1,889.3 3,651.1 3.82 362.51.00 97.01.00 1.00+0.60D 1.007 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 22 Wood Beam LIC# : KW-06016542, Build:20.24.06.04 (c) ENERCALC INC 1983-2023 DESCRIPTION:HDR-2 Project File: 2002 Parton ST.ec6 Project Title:2002 Parton St Engineer: Project ID: Project Descr: Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00Length = 14.833 ft 1 0.110 0.058 1.60 1.007 1.001.00 1.00 4.76 516.1 4,673.4 1.07 464.01.00 27.11.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+L 1 0.6505 7.362 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 4.663 4.043 Max Upward from Load Combinations 4.663 4.043 Max Upward from Load Cases 2.773 2.336 D Only 1.889 1.707 +D+L 4.663 4.043 +D+0.750L 3.969 3.459 +0.60D 1.134 1.024 L Only 2.773 2.336 r Project No.: Date: Calc's Perfomed By: -- ri , 1—. Planning and Buildin A ncy Engineer of Record: Revisions: Approved Sheet: o'FOR PERMIT ISSUA Master ID: Date: P= ZOO(z 00') /001L6-m 7-►i = 2•-�LDlbs/i^ -, S ��y TN-C COV,4e 1 ?y = Z k 6 3zYO 1-C > 168 L,SS 0_K. SANTA ANA CITY COUNCIL Mayor vamezcua@santa-ana.org Mayor Pro Tem, Ward 1 tphan@santa-ana.org Ward 2 bvazquez@santa- ana.org Ward 3 jessielopez@santa-ana.org Ward 4 pbacerra@santa-ana.org Ward 5 jryanhernandez@santa- ana.org Ward 6 dpenaloza@santa-ana.org MAYOR Valerie Amezcua MAYOR PRO TEM Thai Viet Phan COUNCILMEMBERS Phil Bacerra Johnathan Ryan Hernandez Jessie Lopez David Penaloza Benjamin Vazquez CITY OF SANTA ANA PLANNING AND BUILDING AGENCY 20 Civic Center Plaza ● P.O. Box 1988 Santa Ana, California 92702 www.santa-ana.org ACTING CITY MANAGER Alvaro Nuñez CITY ATTORNEY Sonia R. Carvalho CITY CLERK Jennifer L. Hall September 5, 2024 Also sent via email to: santi13.sg@gmail.com Humberto Garcia and Maria Garcia 2002 South Parton Street Santa Ana, CA 92707 Subject: Address Assignment for the detached accessory dwelling unit (ADU) located at 2002 South Parton Street (APN: 015-136-13) in Santa Ana, CA Dear Humberto Garcia and Maria Garcia, The City of Santa Ana Planning and Building Agency (PBA) is the responsible agency for legal addressing within the City of Santa Ana’s jurisdiction. This letter confirms the address assignment for a proposed detached accessory dwelling unit (ADU) located at 2002 South Parton Street (APN: 015-136-13). Notice is hereby given that the following assigned address(es) shall be posted on-site per the approved address plan, attached hereto as Exhibit A. Address(es) to be Activated/Posted 740 W. Saint Andrews P To subdivide commercial and/or residential units into multiple units, a building permit (and all other associated permits), plans, and inspection approvals by the PBA are required. Address(es) will be verified during inspections by the Building Safety Division. Please update your records accordingly. Should you have any questions, feel free to contact me by phone at (714) 667-2719 or by email at jkessler@santa-ana.org. Sincerely, Jeffrey Kessler Planning Technician Exhibit A – Address Plan Address Letter for 2002 S. Parton Street Page 2 of 3 c: Vencent Quaglia, United States Post Office Chris Tuiolosega, United States Post Office Cipriano Corona, Marketing Manager, United States Post Office Alex Alvarez, Postmaster Santa Ana, United States Post Office Federal Express, Administration Cathy Joseph, Garden Grove Unified School District Christine Hy, Garden Grove Unified School District Cathy Slader, Orange Unified School District Orin Williams, Santa Ana Unified School District Yvette Miranda, Santa Ana Unified School District Cristina Bernal, Tustin Unified School District Orange County Fire Authority Neal Kelly, Registrar of Voters Members, Board of Supervisors Southern California Gas Company Southern California Edison Company Claude Parrish, County Assessor's Office SAG, AT&T UPS, Administration City Manager’s Office Beverly Martin, Police Community Services Specialist Boris Duran, Police Systems Manager Jennifer Mendoza, Police Communications Manager Chris Hubbard, Police Systems Support Analyst Alejandra Gutierrez, Treasury & Customer Services Manager Hector Jimenez, Revenue Supervisor Alfonso Chavez, Utilities Customer Services Supervisor Judson Brown, Housing & Neighborhood Development Manager Rudy Rosas, Principal Civil Engineer Zdenek (Zed) Kekula, Principal Civil Engineer Jason Kwak, Building Safety Manager Evelyn LaRocca, Permit Supervisor Kathy Hernandez, Permit Technician Julie Amsden, Permit Technician Ali Pezeshkpour, Planning Manager Jerry Guevara, Senior Planner Yvette Portugal, Code Enforcement Principal Sergio Verino, Code Enforcement Principal Address Letter for 2002 S. Parton Street Page 3 of 3 Exhibit A 2002 S. Parton Street Existing Single- Family Home Sean Lewis <seanalewis@ahaedesignsinc.com> 740 W St Andrew Pl & 2002 S Parton St - Project question Hobbs, Jonathan <jonathanhobbs@ocfa.org>Wed, May 14, 2025 at 6:46 AM To: Sean Lewis <seanalewis@ahaedesignsinc.com> Hi Sean, Based on the plan you provided and no OCFA submittal will be required. Please provide this email to the city as proof you have discussed the project (740 St. Andrew) with me. Jonathan A. Hobbs Fire Prevention Analyst Orange County Fire Authority Office: 714.573.6181 In service of others! From: Sean Lewis <seanalewis@ahaedesignsinc.com> Sent: Tuesday, May 13, 2025 8:43 PM To: Hobbs, Jonathan <jonathanhobbs@ocfa.org> Subject: 740 W St Andrew Pl & 2002 S Parton St - Project question Mimecast Attachment Protection has deemed this file to be safe, but always exercise caution when opening files. CAUTION: This email originated from outside of the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. Hello Jonathan, I hope that this email finds you all well. I was hoping to discuss the subject project with you in-person today, but the staff informed me that you were not in today, so they provided your business card. The attached project is an (e) 463 sq.ft garage conversion with a 537 sq.ft addition to a new 2-story ADU in the City of Santa Ana. The project currently meets all of the OCFA Plan Submittal Criteria Form (SFR) which is attached to this email, but the plan checker referred us to you. I have attached both the form and also the architectural set of plans to this email. Can you please let us know if this is a project that needs to be reviewed by you? Thanks for all of your assistance. Thanks for all of your assistance in advance. Thanks In advance, Sean A Lewis Founder | Principal Designer Phone #: +1 (323) 543-0172 Email: Seanalewis@ahaedesignsinc.com Address: 4947 Barstow St, Los Angeles, CA 90032 [Quoted text hidden] �GECCOORANGE COUNTY FIRE AUTHORIT G, y 7., < Plan Submittal Criteria Form 4,� r cq��f tom! Required for Single Family or Duplex Residences 7HoVLO (Use Commercial form for lots with 3+ dwelling units or new residential tracts) Complete the Project Information and Questionnaire below, then sign and date the Applic Project Information ❑ New Single Family Residence/Duplex ❑ Addition/Remodel ADU Address: 740 W St. ANDREWS PLACE, SANTA ANA, CA 9270 CITY OF SANTA ANA Plans ing and Building A jency SFR Approved FOR PERMIT ISSUANCE Certification. Master ID: Date: ❑ Other Unit #: City or Unincorporated County Area: I ZIP: SANTA ANA 92707 Scope of Work: CONVERT (E) DETACHED 441 S.F GARAGE W/ 59 S.F ADDITION TO FIRST FLOOR + 500 S.F SECOND STORY ADDITION TO NEW DETACHED ADU. ADU WILL CONSIST OF 2 STORIES, (2) BED, (2) BATH, (1) KITCHEN, AND (1) LIVING ROOM. NEW 78 S.F SECOND LEVEL BALCONY/PATIO. ATTACHED UNPERMITTED 503.8 S.F PATIO TO BE DEMOLISED. Existing 441 Area to 559 Total Resulting 1 OOO Stories: 2 I Area Added in Past 2 Years 0 Area: be Added: Area: (excludina this oroiect): Yes No Questionnaire OCFA Plan Type if "Yes" 1. ❑ 0 New — Is this a new single family residence or duplex? *(PR160) Residential Site with Water Availability PR400-402 Fire Sprinkler 2. ❑ FO ADU — Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has (PR400-402) Fire Sprinkler fire sprinklers or a house that will have firesprinklers added as part of thisproject? 3. ❑ F0 Addition — Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire (PR400-402) Fire Sprinkler sprinkler retrofit based on a threshold set by local ordinance? 4. ❑ FO Distance — Is the most remote portion of the addition, ADU or other detached structure greater than *(PR160) Residential Site 140-feet from the fire access roadway? 5. ❑ FO Total Area — Will the addition result in a total area of greater than 3,600 square feet (sf) for non- *(PR160) Residential Site sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all with Water Availability enclosed spaces, such as garages, stairs, and detached structures separated by less than 10-feet? 6. ❑ W1 Remodel — Is this a remodel of a sprinklered building with a scope of work that includes adding or (PR400-402) Fire Sprinkler removing any interior walls? Note: If "Yes", then project must be evaluated by a C-16 licensed contractor to determine if a firesprinkler modification is needed. 7. ❑ F0 Detached Structure — Is this a new detached utility or accessory structure (not an ADU), such as a *(PR160) Residential Site garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold (PR400-402) Fire Sprinkler set by local ordinance? 8. ❑ F0 Gate — Is a gate being installed across a driveway or road that is designated as a fire department (PR180) Gate access roadway, or a driveway or road that serves more than a single home/duplex? 9. ❑ 0 Methane — Is project located in or less than 100' from a "Division of Oil, Gas, and Geothermal *(PR160) Residential Site Resources" (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas *(PR172-174) Methane seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only Test/Mitigation Plans applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000 sf, and ADU's). 10. ❑ 0 Vegetation — Is the property/structure (A) on the perimeter of a community containing, or adjacent to *(PR125) Fuel Modification slopes or hills, or (B) adjacent to an open space or wildland area containing non -irrigated vegetation, (PR182) Accessory or (C) in a State Responsibility Area or Local Responsibility Area "Fire Hazard Severity Zone", as Structure defined by the State, or D near an area that could be affected by a wildfire in the open space. *OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals. Applicant Certification I certify, under penalty of perjury, under the laws of the State of Cali rnia, that the information above is true: Print Name: SEAN LEWIS Signature: Date: 01/02/2025 Phone Number: 3233022657 Email: Attention Building Department Staff — After you've verified all questions were answered accurately as "No", then you may accept this signed form as a written release that an OCFA review is not required. If any questions were answered as "Yes", then the plan type on the right side may be required. If all answers are "No" and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are "Yes" and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination. For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100 �pN'f A qN- \sCH00�►�`� Certificate of Compliance Payment of School Facility Fees Santa Ana Unified School District Name (First, MI, Last) H Umberto A Malri(A Garcia Project Address 140 W . St-. Andrew -Pl. City, State, Zip Code Name (First, MI, Last) Santa Avia , CA 9240'1 CITY OF 51kNTA ANA Planning and Building Agency APpAlzi FOR PERMIT ISSUANCE Telephone iviaser iu: Date: -414-4 3--11 Tract/Parcel Number 10112221DO Telephone Use of Building (check) Type of Project (check) Residential 1� Commercial ❑ Senior Housing ❑ New ❑ Addition d Alteration d Description of Project Convert aara cie A add zed floor -6 AW Number of Square Feet of Residential Space Number of Square Feet of Commercial Space 961 Sq.Ft x $ Sq.Ft x $ 5.1-f (Dev. Fee) (Dev. Fee) Total $ 4,g13.54 Total $ The above representations as to square footage are true. Applicant agrees that if it is later determined that such representations are not true, then this certificate shall automatically terminate, and the appropriate City/County shall be notified. Applicant is hereby noticed that any party filing a protest regarding the imposition of fees pursuant to Government Code Section 53080 must do so within 90 days from the payment of the fee. sexr4-� Applicant `Fume (Please Print) ure /Z Date This certifies that the above -named Applicant has paid school facility fees in compliance with all existing and applicable sections of the GovAnment Code and Education Code. f Of I aol/tA� Authorized Representative Date DISTRIBUTION While - City/County Canary - Applicant Pink - Facilities Page 1 of 1 EXISTING ONE & TWO FAMILY DWELLINGS ELECTRICAL SERVICES UNDERGROUND EXCEPTION CEC 2022 ELC-04 All new utility connections are required to be installed below grade by Santa Ana Municipal Code 41- 626(b). There is a standing exception for one and two family dwellings. This exception applies only when the new electrical service is designed to be fed from below grade as well as overhead. This diagram is a typical unit. The utility is able to feed this cabinet from the top or the bottom without interfering with the distribution wiring. All the circuit breakers and branch circuits are contained in the circuit breaker side of this cabinet. Only listed combination overhead and underground feed service boxes may be used to connect to an overhead utility drop. This exception to an underground fed service applies only to existing single family and two family residences. Planning & Building Agency Permits & Plan Check Section 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 Rigid Conduit Service Entrance Conductor Riser Underground Service Lateral METER Rev. 1/21/2020 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:740 W St. Andrews Place (ADU)Calculation Date/Time:2025-02-24T08:55:08-08:00 (Page 1 of 10) Calculation Description:Title 24 Analysis Input File Name:740 W St. Andrews Place (ADU).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-02-24   08:55:26 GENERAL INFORMATION 01 Project Name 740 W St. Andrews Place (ADU) 02 Run Title Title 24 Analysis 03 Project Location 740 W St. Andrews Place (ADU) 04 City Santa Ana 05 Standards Version 2022 06 Zip code 92707 07 Software Version EnergyPro 9.3 08 Climate Zone 8 09 Front Orientation (deg/ Cardinal)90 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Newly Constructed Addition 13 Number of Bedrooms 2 14 Addition Cond. Floor Area (ft2)1000 15 Number of Stories 2 16 Existing Cond. Floor Area (ft2)0.01 17 Fenestration Average U-factor 0.3 18 Total Cond. Floor Area (ft2)1000.01 19 Glazing Percentage (%)28.57% 20 ADU Bedroom Count 2 21 ADU Conditioned Floor Area 1000 22 Fuel Type Natural gas 23 No Dwelling Unit:No ADDITION ALONE - Project Analysis Parameters 01 02 03 04 05 06 Existing Area (excl. new addition) (ft2) Addition Area (excl. existing) (ft2)Total Area (ft2)Existing Bedrooms Addition Bedrooms Total Bedrooms 0.01 1000 1000.01 0 2 2 ADDITION ALONE - ACCESSORY DWELLING UNIT (ADU) PROJECT ANALYSIS PARAMETERS 01 02 03 04 05 06 07 08 Zone Name Existing Area (excl. new addition) (ft2) ADU Area (excl. existing) (ft2)Total Area (ft2)Existing Bedrooms Addition Bedrooms Total Bedrooms Attached vs. Detached ADU 0.01 1000 1000.01 0 2 2 Detached 425-P010057926A-000-000-0000000-0000 02/24/2025 09:09 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:740 W St. Andrews Place (ADU)Calculation Date/Time:2025-02-24T08:55:08-08:00 (Page 2 of 10) Calculation Description:Title 24 Analysis Input File Name:740 W St. Andrews Place (ADU).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-02-24   08:55:26 COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 425-P010057926A-000-000-0000000-0000 02/24/2025 09:09 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:740 W St. Andrews Place (ADU)Calculation Date/Time:2025-02-24T08:55:08-08:00 (Page 3 of 10) Calculation Description:Title 24 Analysis Input File Name:740 W St. Andrews Place (ADU).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-02-24   08:55:26 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft2 -yr)Margin (EDR1)Margin (EDR2) Space Heating 0 0.89 0 2.4 0 -1.51 Space Cooling 0 28.51 0 29.32 0 -0.81 IAQ Ventilation 0 4.28 0 4.28 0 0 Water Heating 0 33.8 0 30.54 0 3.26 Self Utilization/Flexibility Credit 0 0 Efficiency Compliance Total 0 67.48 0 66.54 0 0.94 Photovoltaics 0 0 Battery 0 Flexibility Indoor Lighting 0 8.06 0 8.06 Appl. & Cooking 0 34.65 0 34.48 Plug Loads 0 46.26 0 46.26 Outdoor Lighting 0 1.75 0 1.75 TOTAL COMPLIANCE 0 158.2 0 157.09 425-P010057926A-000-000-0000000-0000 02/24/2025 09:09 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:740 W St. Andrews Place (ADU)Calculation Date/Time:2025-02-24T08:55:08-08:00 (Page 4 of 10) Calculation Description:Title 24 Analysis Input File Name:740 W St. Andrews Place (ADU).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-02-24   08:55:26 ENERGY USE INTENSITY Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Margin (kBtu/ft2 - yr )Margin Percentage Gross EUI1 25.36 24.53 0.83 3.27 Net EUI2 25.36 24.53 0.83 3.27 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •Cool roof •Variable capacity heat pump compliance option (verification details from VCHP Staff report, Appendix B, and RA3) HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Indoor air quality ventilation •Kitchen range hood •Verified EER/EER2 •Verified SEER/SEER2 •Verified Refrigerant Charge •Airflow in habitable rooms (SC3.1.4.1.7) •Verified HSPF2 •Verified heat pump rated heating capacity •Wall-mounted thermostat in zones greater than 150 ft2 (SC3.4.5) •Ductless indoor units located entirely in conditioned space (SC3.1.4.1.8) •Pipe Insulation, All Lines ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status ADU Conditioned Multi Zone AC1 1000 8.25 DHW Sys 1 New 425-P010057926A-000-000-0000000-0000 02/24/2025 09:09 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:740 W St. Andrews Place (ADU)Calculation Date/Time:2025-02-24T08:55:08-08:00 (Page 5 of 10) Calculation Description:Title 24 Analysis Input File Name:740 W St. Andrews Place (ADU).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-02-24   08:55:26 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg)Wall Exceptions Status North Wall ADU R-15 0 Right 190 30 90 Extension New East Wall ADU R-15 90 Front 180 52.5 90 Extension New South Wall ADU R-15 180 Left 190 8 90 Extension New West Wall ADU R-15 270 Back 180 112 90 Extension New North Wall 2 ADU R-15 0 Right 190 67 90 Extension New East Wall 2 ADU R-15 90 Front 180 0 90 Extension New South Wall 2 ADU R-15 180 Left 190 16.2 90 Extension New West Wall 2 ADU R-15 270 Back 180 0 90 Extension New OPAQUE SURFACES - CATHEDRAL CEILINGS 01 02 03 04 05 06 07 08 09 10 11 Name Zone Construction Azimuth Orientation Area (ft2) Skylight Area (ft2) Roof Rise (x in 12) Roof Reflectance Roof Emittance Cool Roof Roof ADU R-15+1.5 InchAirImperme ab 0 Right 500 0 2 0.26 0.92 Yes FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading Window 1 Window North Wall Right 0 1 30 0.3 NFRC 0.23 NFRC Bug Screen Window 7 Window East Wall Front 90 1 7.5 0.3 NFRC 0.23 NFRC Bug Screen Window 5 Window East Wall Front 90 1 15 0.3 NFRC 0.23 NFRC Bug Screen 425-P010057926A-000-000-0000000-0000 02/24/2025 09:09 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:740 W St. Andrews Place (ADU)Calculation Date/Time:2025-02-24T08:55:08-08:00 (Page 6 of 10) Calculation Description:Title 24 Analysis Input File Name:740 W St. Andrews Place (ADU).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-02-24   08:55:26 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading Door 2 Window East Wall Front 90 1 20 0.3 NFRC 0.23 NFRC Bug Screen Window 8 Window East Wall Front 90 1 10 0.3 NFRC 0.23 NFRC Bug Screen Window 3 Window South Wall Left 180 1 8 0.3 NFRC 0.23 NFRC Bug Screen Door 4 Window West Wall Back 270 1 64 0.3 NFRC 0.23 NFRC Bug Screen Window 6 Window West Wall Back 270 1 24 0.3 NFRC 0.23 NFRC Bug Screen Window 6 2 Window West Wall Back 270 1 24 0.3 NFRC 0.23 NFRC Bug Screen Window 4 Window North Wall 2 Right 0 1 27 0.3 NFRC 0.23 NFRC Bug Screen Door 1 Window North Wall 2 Right 0 1 40 0.3 NFRC 0.23 NFRC Bug Screen Window 9 Window South Wall 2 Left 180 1 4.2 0.3 NFRC 0.23 NFRC Bug Screen Window 2 Window South Wall 2 Left 180 1 12 0.3 NFRC 0.23 NFRC Bug Screen SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab-on-Grade ADU 500 0.1 none 0 80%No 425-P010057926A-000-000-0000000-0000 02/24/2025 09:09 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:740 W St. Andrews Place (ADU)Calculation Date/Time:2025-02-24T08:55:08-08:00 (Page 7 of 10) Calculation Description:Title 24 Analysis Input File Name:740 W St. Andrews Place (ADU).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-02-24   08:55:26 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-15 Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.095 Inside Finish: Gypsum Board Cavity / Frame: R-15 / 2x4 Exterior Finish: 3 Coat Stucco R-15+1.5 InchAirImpermeab Cathedral Ceilings Wood Framed Ceiling 2x6 @ 16 in. O. C.R-15 9 / None 0.041 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-15 / 2x6 Sheathing / Insulation: R-9 Sheathing Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Not Required Not Required N/A n/a n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#) DHW Sys 1 Domestic Hot Water (DHW) HERS Verified Pipe Insulation credit DHW Heater 1 1 n/a None DHW Sys 1-hers-dhw DHW Heater 1 (1) 425-P010057926A-000-000-0000000-0000 02/24/2025 09:09 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:740 W St. Andrews Place (ADU)Calculation Date/Time:2025-02-24T08:55:08-08:00 (Page 8 of 10) Calculation Description:Title 24 Analysis Input File Name:740 W St. Andrews Place (ADU).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-02-24   08:55:26 WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name Heating Element Type Tank Type # of Units Tank Vol. (gal) Heating Efficiency Type Efficiency Rated Input Type Input Rating or Pilot Tank Insulation R-value (Int/Ext) Standby Loss or Recovery Eff 1st Hr. Rating or Flow Rate Tank Location DHW Heater 1 Gas Consumer Instantaneo us 1 0 UEF 0.91 Btu/Hr 200000 0 n/a n/a WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Required Not Required Not Required None Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type Multi Zone AC1 Heat pump heating cooling Heat Pump System 1 1 Heat Pump System 1 1 n/a n/a Setback 425-P010057926A-000-000-0000000-0000 02/24/2025 09:09 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:740 W St. Andrews Place (ADU)Calculation Date/Time:2025-02-24T08:55:08-08:00 (Page 9 of 10) Calculation Description:Title 24 Analysis Input File Name:740 W St. Andrews Place (ADU).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-02-24   08:55:26 HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS VerificationHeating Efficiency Type HSPF/HS PF2/COP Cap 47 Cap 17 Cooling Efficiency Type SEER/SE ER2 EER/EER 2/CEER Heat Pump System 1 VCHP-ductless 1 HSPF2 10 28000 17100 EER2SEER2 21 12.5 Not Zonal Single Speed Heat Pump System 1-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEER/SEER2 Verified Refrigerant Charge Verified HSPF/HSPF2 Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 1-hers-htpump Not Required 0 Required Required Yes Yes Yes Yes VARIABLE CAPACITY HEAT PUMP COMPLIANCE OPTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 10 Name Certified Low-Static VCHP System Airflow to Habitable Rooms Ductless Units in Conditioned Space Wall Mount Thermostat Air Filter Sizing &amp; Pressure Drop Rating Low Leakage Ducts in Conditioned Space Minimum Airflow per RA3.3 and SC3.3.3.4.1 Certified non-continuous Fan Indoor Fan not Running Continuously Heat Pump System 1 Not required Required Required Required Not required Not required Not required Not required Not required INDOOR AIR QUALITY (IAQ) FANS 01 02 03 04 05 06 07 08 09 Dwelling Unit Airflow (CFM)Fan Efficacy (W/CFM)IAQ Fan Type Includes Heat/Energy Recovery? IAQ Recovery Effectiveness - SRE/ASRE Includes Fault Indicator Display?HERS Verification Status SFam ADU IAQVentRpt 53 0.35 Exhaust No n/a / n/a No Yes 425-P010057926A-000-000-0000000-0000 02/24/2025 09:09 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:740 W St. Andrews Place (ADU)Calculation Date/Time:2025-02-24T08:55:08-08:00 (Page 10 of 10) Calculation Description:Title 24 Analysis Input File Name:740 W St. Andrews Place (ADU).ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2025-02-24   08:55:26 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Roben Mardirosian Armen Consulting Engineers 02/24/2025 10540 Jardine Avenue Sunland, CA 91040 (818) 484-0495 Sean Lewis AHAE DESIGN INC 02/24/2025 833 Victor Ave Inglewood, CA, CA 90302 3233022657 425-P010057926A-000-000-0000000-0000 02/24/2025 09:09 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information.