HomeMy WebLinkAbout618 & 620 W Orion Ave - PlanWL WL WL WL WL WL SS SS SS SS SS SS SS G G G G G WL WL WL WL WL WL SS SS SS SS SS SS SS WL WL WL WL WL WL WL WL WL WL WL WL SS SS SS SS SS SS SS SS SS SS G G G G G G G G G G EL WL WLWL SS SSSS G GG EL ELEL ORION AVENUEORION AVENUE 618 W ORION AVE., SANTA ANA, CA PR O P E R T Y L I N E PR O P E R T Y L I N E 11 2 . 5 0 ' 93 . 3 8 ' (E) SINGLE FAMILY DWELLING PROPERTY LINE56.00' 11 2 . 5 0 ' 93 . 3 8 ' 4:12 4:12 41.27' PRO P E R T Y L I N E - F R O N T A G E 18.37' G 29 ' - 1 1 " 15' - 0" 43 ' - 1 1 " (E) CONCRETE DRIVEWAY (E) DRIVEWAY APRON (E) FENCE (E) FENCE (E) WALKWAY (E) WALKWAY (E) ELECTRICAL METER WITH UNDERGROUND FEED (TO BE CONVERTED TO SUBPANEL) 5' - 0" WM 40' - 0" 25' - 0" 11' - 0" (E) TRELLIS (TO BE REMOVED) (E) WATER METER 32 ' - 0 " PUBLIC UTILITY EASEMENT 5' - 0 " 34' - 8" 15 ' - 5 " 10' - 4"11' - 0" ORION AVENUEORION AVENUE 618 W ORION AVE., SANTA ANA, CA PR O P E R T Y L I N E PR O P E R T Y L I N E 11 2 . 5 0 ' 93 . 3 8 ' (E) SINGLE FAMILY DWELLING PROPERTY LINE56.00' 11 2 . 5 0 ' 93 . 3 8 ' 4:12 4:12 4: 1 2 4' - 0 " 4' - 0" 41.27' PRO P E R T Y L I N E - F R O N T A G E 18.37' (N) 800 SF ACCESSORY DWELLING UNIT G 400 AMP DUAL GANG PANEL W/ 200AMP BREAKER FOR (E) RESIDENCE & 200AMP BREAKER FOR (N) ADU 29 ' - 1 1 " 15' - 0" 43 ' - 1 1 " (N) UNDERGROUND ELEC. LINE FIRE SEPARATION DETAIL LINE (E) CONCRETE DRIVEWAY (E) DRIVEWAY APRON (E) FENCE (E) FENCE (E) WALKWAY (E) WALKWAY (E) WALKWAY 12' - 0"40' - 0" 5% 2% 2% 5% 5% 5% 5% 2%2% 5% 5% 5% 2% 5% 2% 2% 5% 5% 2% 2% 5% (E) ELECTRICAL METER WITH UNDERGROUND FEED (TO BE CONVERTED TO SUBPANEL) 3, 5 A5 3,6 A5 4 A5 7 A5 4: 1 2 FUTURE SOLAR PANEL 4:12 4:12 5' - 0" G (N) GAS METER FOR ADU WM 40' - 0" 25' - 0" 11' - 0" 5' - 0 " WM (E) WATER METER (N) WATER METER PER ENCROACHMENT PERMIT SUBMITTAL THROUGH PUBLIC WORKS 3' - 0 " 20 ' - 0 " 32 ' - 0 " PUBLIC UTILITY EASEMENT 5' - 0 " 620 W ORION AVE., SANTA ANA, CA 5-GALLON SHRUB 24-INCH CANOPY TREE 1-GALLON SHRUB 1-GALLON SHRUB G WM MAIN PANEL LOCATION GAS METER WATER METER WATER LINE SEWER LINE SITE LEGEND PROPERTY LINE BUILDING LINE (E) GRASS CONCRETE ROOF HATCH GAS LINE ELECTRICAL LINE FIRE SEPARATION DISTANCE LINE EXISTING TREE 618 & 620 W ORION AVE., SANTA ANA, CA 92707 SCOPE OF WORK: 1. CONSTRUCT A DETACHED ACCESSORY DWELLING UNIT - 800 SF, 2 BED, 2 BATH, 16 SF PORCH 2. TO REMOVE (E) TRELLIS DATA: OWNER/S : HIDEMI FUJITA PARCEL NUMBER : 410-171-21 LOT SIZE : 5,880 SF ZONE : R1 CONTACT NUMBER : 949-414-8799 EMAIL ADDRESS : fkhide@gmail.com TYPE OF CONSTRUCTION ; V-B OCCUPANCY : R-3 VHFHSZ : NO FLOOD ZONE : X THIS PROJECT SHALL COMPLY WITH THE: 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBSC) 2022 CALIFORNIA ENERGY EFFICIENCY STANDARDS (CEES) 2022 CALIFORNIA BUILDING CODE (CBC) CODE REQUIREMENTS: THERE SHALL BE NO TRENCHES OR EXCAVATIONS 5 FEET OR MORE INDEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND OR OBTAINPERMIT FROM STATE OF CALIFORNIA, DIVISION OF OCCUPATIONALSAFETY AND HEALTH (CAL/OSHA). THIS PERMIT AND ANY OTHER SAFETYPERMIT SHALL BE OBTAINED PRIOR TO COMMENCE OF ANY WORK. CAL/OSHA NOTE: 1. 2. 3. a. b. c. 65% OF NONHAZARDOUS CONSTRUCTION AND DEMOLITIONDEBRIS SHALL BE SALVAGED, RECYCLED, AND/OR RESUSED. BUILDING MATERIALS WITH VISIBLE SIGNS OF WATERDAMAGAE SHALL NOTE BE INSTALLED.WALL AND FLOOR FRAMING SHALL NOT BE ENCLOSED WHENTHE FRAMING MEMEBERS EXCEED19% MOISTURE CONTENT. INSULATION PRODUCTS WHICH AREVISIBLY WET OR HAVE HIGH MOISTURE CONTENT SHALL BEREPLACED OR ALLOWED TO DRY PRIOR TO ENCLOSURE INWALLOR FLOOR CAVITIES (CGBSC 4.505.3) PROJECTS, WHICH DISTURB LESS THAN 1-ACRE OR SOILD ANDARE NOT PART OF LARGER DEVELOPMENTS THAT DISTURBMORE THAN 1-ACRE, SHALL MANAGE STORM WATER DRAINAGEDURING CONSTRUCTION. THE FOLLOWING MEASURES MAY BEIMPLEMENTED TO PREVENT FLOODING OF ADJACENTPROPERTIES, PREVENT EROSION, AND RETAIN SOIL RUNOFF ONTHE SITE: WHERE STORM WATER IS CONVEYED TO A PUBLIC DRAINAGESYSTEM, COLLECTION POINT, GUTTER, OR SIMILAR DISPOSALMETHOD, WATER SHALL BE FILTERED BY US OF A BARRIERSYSTEM, WATTLE, OR OTHER METHOD APPROVED BY THEENFORCING AGENCY. COMPLIANCE WITH A LAWFULLY ENACTED STORM WATERMANAGEMENT ORDINANCE RETENTION BASINS OF SUFFICIENT SIZE SHALL BE UTILIZEDTO RETAIN STORM WATER ON THE SITE. CALGREEN NOTES: SHEET INDEX NO.SHEET SHEET NAME 1 A1 PROJECT DATA & SITE PLAN 2 A2 EXISTING HOUSE 3 A3 PROPOSED ADU FLOOR & ROOF PLAN 4 A4 PROPOSED ELECTRICAL PLAN 5 A5 ADU ELEVATIONS & SECTIONS 6 A6 EROSION & SEDIMENT CONTROL PLAN 7 A7 EXISTING & PROPOSED CONTOUR MAP 8 A8 SINGLE FAMILY RESIDENTIAL MANDATORY REQUIREMENTS 9 A9 FRAME BACKING FOR FUTURE GRAB BAR INSTALL. 10 AD.1 ARCHITECTURAL DETAILS 11 AD.2 ARCHITECTURAL DETAILS 12 CG.1 CAL. GREEN REQUIREMENTS 13 CG.2 CAL GREEN REQUIREMENTS 14 S-1 FOUNDATION PLAN 15 S-2 FRAMING PLAN (ADU) 16 SD1 STRUCTURAL DETAILS 17 T24 T24 1. 2. 3. 4. 5. 6. 7. 8. PLANNING CLEARANCE REQUIRED FOR OVERHEADSERVICE LINE. “PV IS A DEFERRED APPROVAL AND BUILDING CANNOTBE OCCUPIED UNTIL PV IS APPROVED BY CITY.” NEW ADU SHALL MATCH EXISTING RESIDENCE ARCHITECTURALSTYLE, BUILDING MATERIALS, WINDOW STYLE, WINDOW FRAMES,ROOFING STYLE, ALL MATERIALS AND DESIGN. RECOMPACT 4’ OVEREXCAVATION PRIOR TO TRENCHING FOR THE UTILITY AND/ORFOUNDATION. 90% COMPACTION REPORT IS REQUIRED AT THE TIME OF FOUNDATIONINSPECTION. DAMP PROOFING, BASE COURSE AND PRE-SATURATION ARE REQUIRED. PROVIDE 5” SLAB ON GRADE REINFORCED WITH #4 AT 18 ” ON CENTERS EACH WAYOVER 4 ” BASE OF ½” OR LARGER CLEAN AGGREGATE WITH 10 MIL VAPOR RETARDER INDIRECT CONTACT WITH CONCRETE. SLAB SHALL BE TIED-IN TO CONTINUOUS 12 ” WIDEX 24” (MINIMUM EMBEDMENT INTO FIRM SOIL) FOUNDATION. CONTINUOUS FOUNDATION MUST BE REINFORCED WITH 2 #5 (OR 3 #4) TOP ANDBOTTOM. ALL CONCRETE SHALL BE FC ’=4,500 PSI (MINIMUM) WITH TYPE V CEMENTMAXIMUM WATER CEMENT RATIO OF 0.45. NO SPECIAL INSPECTION REQUIRED IFCONCRETE TRUCK MIX TICKET IS PROVIDED. MECHANICAL, ELECTRICAL, AND PLUMBING ARE NOT PART OF THIS PLAN REVIEW APPROVAL. THE BUILDING AND SAFETY DIVISION PLAN REVIEW DOES NOT INCLUDE POTENTIAL ELECTRICAL, WATER, OR GAS REVISIONS REQUIRED BY ANY NON-CITY UTILITY COMPANY. IT IS SOLELY ON THE CONTRACTOR TO ENSURE PROPOSED ADDITION OR ALTERATION CAN AND WILL MEET UTILITY COMPANY REQUIREMENTS. MEP ARE SUBJECT TO BUILDING FIELD INSPECTION. GENERAL NOTES: JOB LOCATION SUBJECT PROPERTY IS 0.1 MILES TO THE NEAREST BUS STOP AREA LIVING (SF)GARAGE (SF)PORCH (SF)BEDROOM BATHROOM EXISTING 1,800 480 0 4 3 (N) ADU 800 0 16 2 2 TOTAL 3,096 480 16 6 5 LOT COVERAGE 3,096 LOT SIZE 5,880 % OF LOT COVERAGE 52.65 NOT TO SCALE PROJECT LOCATION SCALE: 1/8" = 1'-0"1 EXISTING SITE PLAN SCALE: 1/8" = 1'-0"2 PROPOSED SITE PLAN EXISTING + NEW ADU + (E) GARAGE + PORCH N N DIG ALERT (811) TO BE CONTACTED AND THAT COMPLIANCE WITH EXCAVATION SAFETY IN ACCORDANCE WITH THE GOVERNMENT CODE 4216 WILL BE FOLLOWED PRIOR TO ANY EXCAVATION TAKING PLACE. 1. 2. MINIMUM 2.06 kW PHOTOVOLTAIC SYSTEM (SOLAR PANELS) SHALL BE ON A SEPARATE PERMIT - DEFERRED SUBMITTAL. PV IS A DEFERRED APPROVAL AND BUILDING CANNOT BE OCCUPIED UNTIL PV IS APPROVED BY CITY. DEFERRED SUBMITTALS: SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : EM S O C A L E N G I N E E R I N G 24 8 8 1 A L I C I A P K W Y . , ST E . E - 2 2 2 , L A G U N A H I L L S 76 0 - 4 8 4 - 6 3 4 3 A1 PROJECT DATA & SITE PLAN 01/14/25 61 8 & 6 2 0 W O R I O N AV E . , S A N T A A N A , CA 9 2 7 0 7 NE W D E T A C H E D AC C E S S O R Y DW E L L I N G U N I T RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N A. ADU / SFD = 800 SF / 1,800 SF = 44.44%A. ADU / SFD = 800 SF / 1,800 SF = 44.44% B. THE ADU SF/ SFD SF RATIO IS FOR PARK & REC FEE PURPOSE ONLY. THE APPLICANT IS RESPONSIBLE FOR THE GIVEN SFR OF THE EXISTING PRIMARY RESIDENCE; BUILDING SAFETY ARE NOT RESPONSIBLE FOR THE ACCURACY OF THE GIVEN SFR SF. 1' - 0 " 1' - 0 " 1' - 0"1' - 0" 1' - 0" 1' - 0 " 4: 1 2 4: 1 2 DN (E) MASTER BATH(E) MASTER BATH (E) MASTER BEDROOM(E) MASTER BEDROOM (E) BEDROOM #1(E) BEDROOM #1 (E) BEDROOM #2(E) BEDROOM #2 (E)(E) BATH #1BATH #1 UP (E) KITCHEN(E) KITCHEN(E) LIVING(E) LIVING (E) DINING(E) DINING (E) GARAGE(E) GARAGE (E) FOYER(E) FOYER (E) 1/2 (E) 1/2 BATHBATH SCALE: 1/4" = 1'-0"3 EXISTING ROOF PLAN SCALE: 1/4" = 1'-0"4 EXISTING ELEVATION SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : EM S O C A L E N G I N E E R I N G 24 8 8 1 A L I C I A P K W Y . , ST E . E - 2 2 2 , L A G U N A H I L L S 76 0 - 4 8 4 - 6 3 4 3 A2 EXISTING HOUSE 10/10/24 61 8 & 6 2 0 W O R I O N AV E . , S A N T A A N A , CA 9 2 7 0 7 NE W D E T A C H E D AC C E S S O R Y DW E L L I N G U N I T SCALE: 1/4" = 1'-0"2 EXISTING SECOND FLOOR PLAN SCALE: 1/4" = 1'-0"1 EXISTING FIRST FLOOR PLAN N N N RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N REF ATTIC VENT CALCULATION AREA VENTILATED 800 SF RATE REQ. VENTS: 150 768 SQ.IN TYPE O'HAGING VENT QTY.AREA PER UNIT 11 72 SQ.IN TOTAL AREA PROVIDED 792 SQ.IN 14"x18" GABLE END VENT 0 110 SQ.IN 0 SQ.IN 24"x12" DORMER VENT 0 100 SQ.IN 0 SQ.IN 2.5" SCREENED 3-HOLE VENTS 0 15 SQ.IN 0 SQ.IN 5.5"x14.5" SOFFIT VENTS 0 65 SQ.IN 0 SQ.IN TOTAL VENTILATION PROVIDED 792 SQ.IN WALL AREA WALL OPENING AREA FIRE WALL OPENING CALCULATIONS 360 SQ. F. 43.5 SQ. F. % OF WALL OPENING 12.03 % WALL LOCATION SOUTH WALL 360 SQ. F. 16.67 SQ. F. 4.6 % NORTH WALL 180 SQ. F. 23.5 SQ. F. 13.0 % SOUTH WALL A-A A5 B-B A5 SDCM 100A SERVICE SUB PANEL WITH 225 AMP MIN. BUSBAR RATING 60 AMP PANEL FOR FUTURE ESS USE 15 40' - 0" 20 ' - 0 " 40' - 0" WH 5' - 10"15' - 3"5' - 10"2' - 2"11' - 0" 12' - 7"2' - 0"5' - 0"20' - 5" 20 ' - 0 " 10 ' - 0 " 3' - 3 " 3' - 1 0 " 3' - 0 " 4' - 0 " 5' - 0 " 10 ' - 0 " 3' - 9 " 3' - 6 " 3' - 9 " 10 ' - 0 " 4' - 0 " 3' - 0 " 5' - 0 " 3' - 6 " 8' - 6"5' - 0"6' - 7"3' - 6"4' - 9"5' - 0"6' - 8" SD SD ACU BATH #1BATH #1 CH: 9'-0" 4' - 2 " 1' - 8 " 2' - 6 " 2' - 6 " 2' - 1 0 " 7' - 5 " BEDROOM #1BEDROOM #1 CH: 9'-0" BEDROOM #2BEDROOM #2 CH: 9'-0" BATH #2BATH #2 CH: 9'-0" CL O S E T C L O S E T CL O S E T C L O S E T 06 02 11 16 12 16 12 06 02 11 LIVINGLIVING CH: 9'-0" DINING & KITCHENDINING & KITCHEN CH: 9'-0" W1W2W1 W2 W1 D3 D3 D4 D1 W1 W3 D5 D2 D5D22' - 1 " 09 10 01 08 07 14 15' - 9"2' - 9"21' - 6" ATTIC ACCESS 22"X30" 2 A4 03 1' - 0 " 0' - 6 " 3' - 0 " 3' - 0 " 7' - 1 " 1' - 8 " 2' - 6 " 2' - 5 " 2' - 6 " EGRESS EGRESS 4' - 0 " 4' - 0" 7' - 0 " LIVINGLIVING 04 3 A5 3 A5 3 A5 3 A5 3 A5 WALL LEGEND PROPOSED WALL PROPOSED FIRE -RATED WALL DOOR SCHEDULE TAG DOOR TYPE OPERATION WIDTH HEIGHT QTY D1 SOLID SWINGING 3' - 0"6' - 8"1 D2 SOLID SWINGING 2' - 6"6' - 8"2 D3 WOOD CLOSET SLIDING 5' - 0"6' - 8"2 D4 LOUVERED EXTERIOR SWINGING 2' - 6"6' - 8"1 D5 SOLID SWINGING 3' - 0"6' - 8"2 WINDOW SCHEDULE TAG QTY TYPE/OPERATIO N MATERIAL WIDTH HEIGHT HEAD HEIGHT U-Value SHGC W1 4 SLIDING VINYL FRAME W/ LOW E-DOUBLE PANE GLASS 5' - 0"4' - 0"6' - 8"NFRC 0.35 W2 2 SLIDING VINYL FRAME W/ LOW E-DOUBLE PANE GLASS 3' - 6"1' - 0"6' - 8"NFRC 0.35 W3 1 SLIDING VINYL FRAME W/ LOW E-DOUBLE PANE GLASS 3' - 0"3' - 0"6' - 8"NFRC 0.35 N 1. 2. 3. THE ATTIC ACCESS SHALL BE A MINIMUM OF 22" X 30". A THIRTY- INCH MINIMUM CLEAR HEAD ROOM SHALL BEPROVIDED ABOVE THE ATTIC ACCESS. ATTIC ACCESS SHALL BE LOCATED AT A READILY ACCESSIBLE LOCATION MECHANICAL VENTILATION IS NOT LESS THAN 6 AIR CHANGES PER HOUR TYPE. THE POINT OF DISCHARGE OFEXHAUST AIR SHALL BE AT LEAST 3 FEET FROM ANY OPENING INTO THE BUILDING. THE EXHAUST VENT SHALL BEEQUIPPED WITH BACK-DRAFT DAMPER TO COMPLY WITH ENERGY REGULATIONS. PROVIDE OUTDOOR COMBUSTION AIR OPENINGS FOR THE MECHANICAL CLOSET WITH THE 2 PERMANENT OPENINGSMETHOD PER CMC SECTION 701.4.1. ONE OPENING SHALL COMMENCE WITHIN12 INCHES OF THE TOP AND THE OTHERCOMMENCING WITHIN 12 INCHES OF THE BOTTOM OF THE ENCLOSURE VENTILATION NOTES: A. B. C. PROVIDE NO LESS THAN 30% UPPER VENTS. BE INSTALLED ON VERTICAL ATTIC SURFACES AND GABLE ENDS. WHEN INSTALLED IN ENCLOSED RAFTER SPACES A MINIMUM AIR SPACE OF 1" MUST BE PROVIDED AND VENTILATIONBE PROVIDED AT UPPER AND LOWER END OF EVERY RAFTER BARRIER. RADIANT BARRIER INSTALLATION SHALL COMPLY WITH THE FOLLOWING: 1. 2. 3. 4. 5. 6. 7. SAFETY OR TEMPERED GLAZING REQUIRED IN THE FOLLOWING LOCATIONS: GLAZING IN ENCLOSURES FOR OR WALLFACING HOT TUBS, WHIRLPOOLS, BATHTUBS AND SHOWERS WHERE THE BOTTOM EXPOSED EDGE IS LESS THAN 60INCHES MEASURED VERTICALLY AVOVE A STANDING OR WALKING SURFACE (CRC R308.4) CEMENT, FIBER-CEMENT, FIBER-MAT REINFORCED CEMENT, GLASS MAT GYPSUM OR FIBER-REINFORCED GYPSUMBACKERS SHALL USED AS A BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL AND CEILING PANELS INSHOWER AREAS. (R702.4.2 CRC) SHOWERS AND TUB-SHOWER COMBINATION VALVES SHALL BE EQUIPPED WITH A MEANS TO LIMIT THE MAXIMUMSETTING OF THE VALVE TO 120 DEGREES F (CPC 408.3) NEW ADU SHALL MATCH EXISTING RESIDENCE ARCHITECTURALSTYLE, BUILDING MATERIALS, WINDOW STYLE, WINDOW FRAMES,ROOFING STYLE, ALL MATERIALS AND DESIGN. VENT OPENINGS SHALL BE PROVIDED WITH CORROSION-RESISTANT WIRE MESH WITH 1/16" MINIMUM TO 1/4" MAXIMUMOPENINGS. A MINIMUM OF A 1- INCH AIRSPACE MUST BE MAINTAINED BETWEEN THE INSULATION AND THE ROOF SHEATHING ATTHE LOCATIONS OF THE VENTS. [CRC R806] BATHROOM EXHAUST FANS SHALL BE ENERGY STAR COMPLIANT, DUCTED TO TERMINATE OUTSIDE THEBUILDING, AND CONTROLLED BY A HUMIDISTAT CAPABLE OF BEING ADJUSTED BETWEEN THE RELATIVE HUMIDITYRANGE OF 50 TO 80 PERCENT. [CGBC 4.506] WALL COVERING SHALL BE CEMENT PLASTER, TILE OR APPROVED EQUAL TO 72 INCHES ABOVE DRAIN AT SHOWERSOR TUB WITH SHOWERS. MATERIALS OTHER THAN STRUCTURAL ELEMENTS ARE TO BE MOISTURE RESISTANT. [CRCR307.2] NOTES: N SCALE: 1/4" = 1'-0"1 PROPOSED FLOOR PLAN KEYNOTESKEYNOTES 01 DRYER; A) PROVIDE 4" DIA. SMOOTH METAL DUCT FOR DRYER EXHAUST EXTENDING TO OUTSIDE W/ BACK DRAFT DAMPER (36" MIN. AWAY FROM OPENING). ;B) MAX. VENT DUCT LENGTH OF 14'. ;C) DOOR AT LAUNDRY ROOM MUST BE LOUVERED TO ALLOW DRYERS TO HAVE SUFFICIENT MAKE-UP AIR.;D) THE SPECIFICATION WILL BE ON A DEFERRED SUBMITTAL. :E) THE DRYER MOISTURE EXHAUST DUCT TO BE METAL OR MOISTURE RATED PVC WITH A SMOOTH INTERIOR SURFACE W/O SCREWS. 02 MINIMUM SHOWER SIZE 1,024 SQ. IN. WITH NO LESS THAN 30" IN ANY DIRECTION (MUST ENCOMPASS A 30" CIRCLE). SHOWER DOORMIN. 22" WIDE, TEMPERED. WATER CLOSET MUST BE CENTERED IN A 30" CLEAR SPACE AND MUST HAVE A 24" CLEAR IN FRONT. FLOORS AND WALL SHALL BE FINISHED WITH A NONABSORBENT SURFACE, SUCH WALL SURFAVES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR. 03 22" x 30" ATTIC ACCESS, WITH 30-INCHES MINIMUM CLEAR UNOBSTRUCTED HEADROOM ABOVE THE CEILING. (CRC R807). 04 EXTERIOR LANDING AT THE EXTERIOR DOOR SHALL HAVE A LENGTH MEASURED IN DIRECTION OF TRAVEL NOT LESS THAN 36 INCHES WITH 2% MAX SLOPE. [CRC RS311.3] 06 CONTINUOUS REINFORCING BACKING FOR FUTURE GRAB BARS. CRC SECTION R327.1.1 ;A) REINFORCEMENT SHALL BE A MINIMUM OF 2X8 SOLID LUMBER AND SHALL BE LOCATED BETWEEN 32 INCHES AND 39-1/4 INCHES ABOVE THE FINISHED FLOOR FLUSH WITH THE WALL FRAMING. ;B) WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. EXEMPTION #1: WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE WALL CAPABLE OF ACCOMMODATING A GRAB BAR, THE BATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION OF FLOOR -MOUNTED FOLDAWAY OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS APPROVED BY THE ENFORCING AGENCY.; C) INFORMATION AND/ OR DRAWINGS IDENTIFYING THE LOCATION OF GRAB BAR REINFORCEMENT SHALL BE PLACED IN THE OPERATION AND MAINTENANCE MANUAL IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE. CHAPTER 4. DIVISION 4.4 CRC SECTION R3271.1.1.; D) SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE FRAMING IS PROVIDED.; D) REINFORCEMENT SHALL NOT BE REQUIRED IN WALL FRAMING FOR PRE-FABRICATED SHOWER ENCLOSURES AND BATHTUB WALL PANELS WITH INTEGRAL FACTORY-INSTALLED GRAB BARS OR WHEN FACTORY-INSTALLED REINFORCEMENT FOR GRAB BARS IS PROVIDED. EXCEPTION #2. ;E) SHOWER ENCLOSURES THAT DO NOT PERMIT INSTALLATION OF REINFORCEMENT AND/ OR GRAB BARS SHALL BE PERMITTED, PROVIDED REINFORCEMENTS FOR INSTALLATION OF FLOOR-MOUNTED GRAB BARS OR AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. EXCEPTION #3. 07 AIRCONDITIONER OUTDOOR UNIT 08 50-GAL ELECTRIC HEAT PUMP WATER HEATER WITH PRESSURE WATER RELIEF VALVE WITH DRAIN OUTSIDE WATER HEATER. CPC 504.6. SE DETAIL 1 2/AD.1.ELECTRIC WATER HEATER, SPECIFICATIONS PER ENERGY DOCUMENTATION 09 LOCAL EXHAUST VENTILATION HOOD, MIN. 110 CFM 10 REFRIGERATOR SPACE W/ COLD WATER STUB-OUT FOR ICEMAKER (VERIFY SIZE W/ MNFR). IT SHALL BE NEEA HEAT PUMP PER T-24. 11 30" x 60" TUB/SHOWER W/ CURTAIN ROD, IMPERVIOUS SURROUND ON 3 WALLS +7'-0" (MIN. 72"). 12 LAVATORY SINK [CPC TABLE 422.1] [PENETRATIONS IN WALL LINE (I) SHALL COMPLY WITH CRC R302.4] 14 ELECTRIC PANEL 15 KITCHEN SINK W/ GARBAGE DISPOSAL (SEE CALGREEN SHEET FOR MAX FLOW RATE) 16 WIRING DEVICES SHALL BE BETWEEN 15" AND 48" ABOVE FINISH FLOOR SCALE: 1/4" = 1'-0"2 PROPOSED ROOF PLAN SHEET NO.: SHEET TITLE: AS SHOWN SCALE: DATE: DR A W I N G S P R O V I D E D B Y : EM S O C A L E N G I N E E R I N G 24 8 8 1 A L I C I A P K W Y . , ST E . E - 2 2 2 , L A G U N A H I L L S 76 0 - 4 8 4 - 6 3 4 3 A3 PROPOSED ADU FLOOR & ROOF PLAN 10/25/24 61 8 & 6 2 0 W O R I O N AV E . , S A N T A A N A , CA 9 2 7 0 7 NE W D E T A C H E D AC C E S S O R Y DW E L L I N G U N I T RE V I S I O N T A B L E NU M B E R DA T E RE V I S E D B Y DE S C R I P T I O N LEVEL 1, F.F. LEVEL 1, T.O.P. GRADING LEVEL T.O.R. 0' - 8 " 3' - 9 " 13 ' - 5 " TOP OF THE WINDOW STUCCO PAINTED TO MATCH EXISTING MAIN HOUSE EXTERIOR FINISH 4 A5 4:12 SLOPE ASPHALT SHINGLE CLASS "A" OVER #30 FELT. OWENSCRONIGN ROOFING ASPHALT ICC-ES-ESR-1389 & ESR-3537. INSTALLATION OF ROOFING SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS (TYP.) TO MATCH EXISTING HOUSE ROOFING MATERIAL 6 A5 9' - 0 " 2' - 4 " 6' - 8 " LEVEL 1, F.F. LEVEL 1, T.O.P. GRADING LEVEL T.O.R. 4:12 SLOPE ASPHALT SHINGLE CLASS "A" OVER #30 FELT. OWENSCRONIGN ROOFING ASPHALT ICC-ES-ESR-1389 & ESR-3537. INSTALLATION OF ROOFING SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS (TYP.) TO MATCH EXISTING HOUSE ROOFING MATERIAL 0' - 8 " 9' - 0 " 3' - 9 " 13 ' - 5 " 6' - 8 " 2' - 4 " 5 A5 2 A5 7 A5 STUCCO PAINTED TO MATCH EXISTING MAIN HOUSE EXTERIOR FINISH LEVEL 1, F.F. LEVEL 1, T.O.P. GRADING LEVEL T.O.R. TOP OF THE WINDOW 7 A5 4:12 SLOPE ASPHALT SHINGLE CLASS "A" OVER #30 FELT. OWENSCRONIGN ROOFING ASPHALT ICC-ES-ESR-1389 & ESR-3537. INSTALLATION OF ROOFING SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS (TYP.) TO MATCH EXISTING HOUSE ROOFING MATERIAL 9' - 0 " 0' - 8 " 2' - 4 " 6' - 8 " 5 A5 VERTICAL WOOD SIDING PAINTED TO MATCH EXISTING MAIN HOUSE EXTERIOR FINISH 2 A5 3' - 9 " 13 ' - 5 " LEVEL 1, F.F. LEVEL 1, T.O.P. GRADING LEVEL T.O.R. 9' - 0 " 0' - 8 " 6' - 8 " 2' - 4 " FUTURE SOLAR PANEL 4:12 SLOPE ASPHALT SHINGLE CLASS "A" OVER #30 FELT. OWENSCRONIGN ROOFING ASPHALT ICC-ES-ESR-1389 & ESR-3537. INSTALLATION OF ROOFING SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS (TYP.) TO MATCH EXISTING HOUSE ROOFING MATERIAL STUCCO PAINTED TO MATCH EXISTING MAIN HOUSE EXTERIOR FINISH 4 A5 5 A5 TOP OF THE WINDOW 3' - 9 " 13 ' - 5 " 24 GA. RIDGE FLASHING UNDERLAYMENT W/ 12" MIN. OVERLAP RIDGE BOARD, SEE STRUCTURAL SHEETS ROOF RAFTER, SEE STRUCTURAL SHEETS INSULATION (IF REQUIRED) ASPHALT SHINGLE, LAND MARK, ICC-ES-ESR-1389 & ESR-3537 ROOF UNDERLAYMENT ROOF SHEATHING NOTE: PROVIDE EITHER 1" MINIMUM CLEARANCE BETWEEN INSULATION AND ROOF SHEATHING OR USE INSULATION BAFFLE FOR RAFTER SPACE VENTILATION INTERIOR FINISH 2X WALL STUDS SILL PLATE, PRESSURE TREATED CONC. SLAB 10 ML POLY VAPOR DIFFUSION RETARDER IS EXTENDED UNDER FOOTING 4" THICK BASE OF 1/2" OR LARGER CLEAN AGGREGATE R-15 INSULATION PLYWOOD SHEATHING PER STRUCT. MIN 5/8" CDX EXTERIOR FINISH 26 GAGE WEEP SCREED 2" M I N AT P A V E D 6" M I N 8" M I N FINISH GRADE 2x 4 S T U D RAFTER CEILING JOIST 7/8" STUCCO UNDER EAVE NO EAVE VENTS PERMITTED LEVEL 1, F.F. LEVEL 1, T.O.P. GRADING LEVEL T.O.R. 4:12 SLOPE ASPHALT SHINGLE CLASS "A" OVER #30 FELT. OWENSCRONIGN ROOFING ASPHALT ICC- ES-ESR-1389 & ESR-3537. INSTALLATION OF ROOFING SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS (TYP.) TO MATCH EXISTING HOUSE ROOFING MATERIAL 5 A5 1 A5 4 A5 13 ' - 5 " 3' - 9 " 9' - 0 " 0' - 8 " R-15 INSULATIONBEDROOM #2BEDROOM #2 BATH #1BATH #1 SLAB ON GRADE R-19 INSULATION R-38 INSULATION1/2" GYPSUM BOARD BATH #2BATH #2 LIVINGLIVINGCLOCLO 1 A5 7/8" STUCCO UNDER RAKE NO VENTS PERMITTED RIDGE BEAM 2X4 STUD 1X6 SHIP-LAPS 2X LOOK-OUT @24" O.C.BN 2X BLKG 1/2" OSB PLWD ROOF SHEAT G MIN. CLASS B A35 PER SCHED. BN2X FASCIA 2X CRIPPLES @ 16" OC 2X BLKG EN. 4X HDR WHERE OCCURS 45° 2X4 BRACE @ 48" O.C. W/ 3-16D TOE NAILS EA. END. A35 PER SCHED. 2X DBL TOP PLATES 2X STUDS @ 16" O.C. EXTERIOR(N) ADU, (N) GARAGE, OR INTERIOR OF BLDG. 2x4 STUD WALL 5/8" TYPE "X" GYPSUM BOARD 7/8" STUCCO INSULATION PER PLAN 5/8" DRYWALL SHALL EXTEND UP THROUGH ATTIC SPACES 7/8" STUCCO NO EAVE VENTS PERMITTED SHEAR WALLWHERE OCCURS ON PLAN INSULATION PER PLAN 2x4 STUD WALL GYPSUM BOARD W/ SEMI-VAPOR PERMEABLE (LATEX) PAINT ROOF RAFTER, SEE STRUCTURAL SHEETS RADIANT BARRIER PER T24 EMITTANCE OF 0.05 OR LESS INSULATION PER PLAN STUCCO 1. A. B. C. 2. ALL EXTERIOR WALL ASSEMBLIES SHALL INCLUDE: TWO LAYERS OF GRADE D OR 60 MINUTE GRADE D PAPER APPLIED OVER ALL WOOD BASE SHEATHING. (CRC R703.7.3 & R703.2). A MINIMUM 0.019 INCH (NO. 26 GALVANIZED SHEET GAGE)CORROSION-RESISTANT WEEP SCREED. (CRC 703.1.1 & R703.7.2.1) THE SCREED SHALL BE INSTALLED WITH THE WEEP OPENINGS LOCATED A MINIMUM 1 INCH BELOW FOUNDATION PLATE LINE AND 4INCHES ABOVE FINISH GRADE OR 2-INCHES ABOVE PAVED AREAS.(CRC R703.1.1 & R703.7.2.1) -ASPHALT ROOF SHINGLES "WEATHER WATCH" ICE &WATER SHIELD AS 30# FELT PAPER MANUFACTURED BYGAF OR EQUAL. INSTALL AS PER MANUFACTURER'SSPECIFICATIONS 1/2" OSB PLYWOOD SHEATHING ( TOMATCH WITHIN EXISTING ROOF/ MATERIAL % COLOR), TYP.OWENS CORNING ROOFING ASPHALT ESR # 1372.CRRC PRODUCT ID # 0890-0013 EXTERIOR CONSTRUCTION ASSEMBLY SCALE: 1/4" = 1'-0"1 NORTH ELEVATION SCALE: 1/4" = 1'-0"4 EAST ELEVATION PLASTER WEEP SCREEDNTS 1RIDGE DETAIL NTS 21-HR FIRE RATED WALL NTS 3RAKE DETAIL NTS 4 SCALE: 1/4" = 1'-0"3 WEST ELEVATION SCALE: 1/4" = 1'-0"2 SOUTH ELEVATION NTS 5FIRE RATED EAVE DTL. SCALE: 1/4" = 1'-0"5 SECTION A-A SCALE: 1/4" = 1'-0"6 SECTION B-B SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : EM S O C A L E N G I N E E R I N G 24 8 8 1 A L I C I A P K W Y . , ST E . E - 2 2 2 , L A G U N A H I L L S 76 0 - 4 8 4 - 6 3 4 3 A5 ADU ELEVATIONS & SECTIONS 12/13/2024 61 8 & 6 2 0 W O R I O N AV E . , S A N T A A N A , CA 9 2 7 0 7 NE W D E T A C H E D AC C E S S O R Y DW E L L I N G U N I T NTS 6FIRE RATED RAKE DTL. NOTES: EXTERIOR BUILDING AND ROOFING MATERIALS SHALL MATCH THAT OF THE EXISTING PRIMARY DWELLING IN TEXTURE, COLOR AND FINISH. NTS 7FIRE RATED NO EAVE DTL. RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : EM S O C A L E N G I N E E R I N G 24 8 8 1 A L I C I A P K W Y . , ST E . E - 2 2 2 , L A G U N A H I L L S 76 0 - 4 8 4 - 6 3 4 3 A8 SINGLE FAMILY RESIDENTIAL MANDATORY REQUIREMENTS 10/10/24 61 8 & 6 2 0 W O R I O N AV E . , S A N T A A N A , CA 9 2 7 0 7 NE W D E T A C H E D AC C E S S O R Y DW E L L I N G U N I T RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : EM S O C A L E N G I N E E R I N G 24 8 8 1 A L I C I A P K W Y . , ST E . E - 2 2 2 , L A G U N A H I L L S 76 0 - 4 8 4 - 6 3 4 3 A9 FRAME BACKING FOR FUTURE GRAB BAR INSTALL. 10/10/24 61 8 & 6 2 0 W O R I O N AV E . , S A N T A A N A , CA 9 2 7 0 7 NE W D E T A C H E D AC C E S S O R Y DW E L L I N G U N I T RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N SOLID BACKING HEADER ROUGH OPENING JAMB SILL SILL FLASHING HEADER JAMB SILL ROUGH OPENING 2" CONTINUOUS BEAD OF SEALANT UNDER NAILING FLANGE. HEAD FLASHING WINDOW FRAMING OR SIMILAR OPENING LINE OF NAILING FLANGE BUILDING PAPER TYP. WINDOW FRAME OR SIMILAR OPENING CUT AWAY EXCESS BLDG. PAPER AT OPENING 4" M I N . BUILDING PAPER UNDER SILL STRIP STEP 4: STEP 3: STEP 2: STEP 1: · ATTACH SILL STRIP OF 9" WIDE VYCOR V40 WEATHER BARRIER STRIP WITH TOP EDGE EVEN WITH THE TOP OF THE ROUGH SILL. · PROVIDE SOLID BACKING AT ALL AREAS WHERE FLASHING MATERIAL LAPPING WILL OCCUR. · EXTEND THIS STRIP AT LEAST 11" BEYOND THE EDGE OF THE ROUGH OPENING. · ATTACH FLASHING MATERIAL WITH GALVANIZED ROOFING NAILS OR CORROSION- RESISTANT STAPLES. · ATTACH JAMB STRIPS OF 9" WIDE MOISTOP FLASHING MATERIAL WITH INSIDE EDGE EVEN WITH THE JAMB OF THE ROUGH OPENING. · START JAMB STRIPS 2" BELOW SILL STRIP AND EXTEND 4" ABOVE LOWER EDGE OF HEADER. · APPLY A CONTINUOUS BEAD OF SEALANT TO THE BACK OF THE FRAME NAILING FLANGE · PLACE AND SECURE FRAME INTO ROUGH OPENING WITH FLANGES OVER THE INSTALLED JAMB AND SILL MOISTOP FLASHING MATERIAL. · APPLY AN ADDITIONAL LAYER OF 9" WIDE VICOR V40 WEATHER OVER THE JAMB NAILING FLANGE. · ATTACH 9" WIDE VYCOR V40 WEATHER BARRIER STRIP OVER THE HEAD FLANGE. EXTEND THIS STRIP 2" BEYOND THE OUTER EDGE OF THE JAMB FLASHING MATERIAL. -STARTING FROM THE BASE OF THE WALL, APPLY BUILDING PAPER UNDER THE SILL STRIP AND CUT ANY EXCESS BUILDING PAPER THAT MAY EXTEND ABOVE THE SILL AND BETWEEN THE JAMBS OF THE OPENING. -APPLY THE NEXT COURSE OF BUILDING PAPER (BUTTING TO THE FRAME OPENING) OVER THE JAMB FLASHING MATERIAL. -APPLY SUCCEEDING LAYERS OF BUILDING PAPER IN SHINGLE BOARD FASHION UP THE WALL, LAPPING COURSES A MINIMUM OF 6". 1.SECTION 1402 OF THE 2019 EDITION OF THE U.B.C. STATES "EXTERIOR OPENINGS EXPOSED TO THE WEATHER SHALL BE FLASHED IN A MANNER AS TO MAKE THEM WEATHERPROOF." THE PROCEDURE ABOVE IS RECOMMENDED TO ACHIEVE THIS INTENT FOR THE FLASHING OF WALL OPENINGS TO INCLUDE BUT NOT LIMITED TO: WINDOWS, DOORS, VENTS, ETC. 2.ALL MATERIALS SHALL BE IN STRICT CONFORMANCE WITH U.B.C. STANDARD 14-1 3.APPLICATION OF FINISH MATERIALS OVER FLASHING MATERIALS SHOWN SHALL BE AS SPECIFIED BY CODE REQUIREMENTS, MANUFACTURER'S INSTRUCTIONS AND THE BEST PRACTICES OF THE TRADE. 4.ADDITIONAL MATERIALS, ie. METAL HEAD FLASHING, ELASTOMERIC SHEET WATERPROOFING ETC. MAY OCCUR, DEPENDING ON THE SPECIFIC FINISH MATERIALS BEING USED. REFER TO INDIVIDUAL DETAILS FOR ADDITIONAL INFORMATION. NOTES: 4" 4" 4" 4" 4" 3" 4" 4" 4" 4"G.S.M. 3/ 8 " G.S.M. FLASHING FLANGE SOLDER ALL SEAMS SLOPE TOP 1/8" PER/ 12" G.S.M. FLASHING COLLAR, SEE SPECIFIC APPLICATION DETAIL FOR FURTHER INFO. FLASHING FIN AT WOOD MEMBERS, SEE SPECIFIC APPLICATION DETAIL RECTANGULARRECTANGULAR DRIP / INTERLOCKDRIP / INTERLOCK G.S.M. FLASHING FLANGE SOLDER ALL SEAMS G.S.M. FLASHING COLLAR, SEE SPECIFIC APPLICATION DETAIL FOR FURTHER INFO. ROUNDROUND SEE PLANS FOR SPECIFIC PENETRATION SIZE 26 GA 1-PIECE GSM PAN FLASHING SOLDIER ALL JOINTS ISOMETRIC (PARTIAL) WEATHERSHIP BASE ADJUSTABLE ALUM. CLAD THRESHOLD ONE-PIECE SOLDIERED SHEET MTL. PAN FLASHING 2x PTDF SLEEPER (ATTACH PER S.D.) 1x2 CEDAR TRIM SEE 1/AD. 1 FOR ADDITIONAL FLASHING INFO. HARDSCAPE SLAB SLOPE4" U O N BUILDING SLAB 3/ 8 " - 3 / 4 " FINISH FLR. DR. FRAME BEYOND DOOR 6" 4" V.I.F. 2" M I N . 1/ 2 " PRESSURE RELIEF VALVE/ DRAIN ENDS OUTSIDE =6" FROM GRD. SOLID BLOCKING. 5/8" GYPSUM BOARD1/4" x 3" MIN. LAG SCREW INTO LEDGER W/ 2x4 WOOD LEDGER WASHER 3/4"x24 GAUGE PERFORATED STEEL PLUMBERS TAPE MIN. 1" 6" MIN . HOT COLD T&P VALVE2x4 WOOD LEDGER OVERFLOW WATERTIGHT PAN W/ 1" DRAIN TO PREVENT LEAKAGE FU L L H E I G H T SEISMIC BRACE SEISMIC BRACE WATER HEATER 4 " UP P E R 1 / 3 LO W E R 1 / 3 18 " MI N . PLATFORM. MUST SUPPORT WATER HEATER ON ITS OWN FEET FINISH FLOOR GAS MIN. CLR. PROVIDE 2 STRAPS THE UPPER 1/3 AND LOWER 1/3 OF THE WATER HEATER OVERALL HEIGHT. PER CPC 510.5 GYPSUM BOARD, 1" MIN. THK. 1/4"X5" MIN. LAG SCREW INTO STUDS W/ WASHER. 4" ELASTOMERIC SHEET WATERPROOFING EXTEND AS NOTED SLOPE METAL FLASHING WITH DRIP EXTEND 4" MIN ABOVE CEDAR WOOD TRIM PER ELEVATION WINDOW FRAME WINDOW FRAME SEALANT WOOD TRIM PER ELEVATION ELASTOMERIC SHEET WATERPROOFING EXTEND AS NOTED DBL 2x SILL 2x BLOCKING OMIT AT PLYWD. SHEARWALL GYP. BD. GYP. BD. HEADER PER PLAN HEAD SILL 0' - 6 " WALL SHEATHING PER PLAN, TYP. 2X4 DF#2 @ 16 TYP. OC 2X SILL DF#2 P.T.D.F. SILL PLATE W/ ANCHOR BOLTS PER AB SCHEDULE S.S.D. ONE POUR 12" MAT SLAB S.S.D. NATURAL UNDISTURBED GRADE #4 @ 18" O.C.E.W. S.S.D. HORIZONTAL SIDING WOOD OVER WATER-RESISTIVE BARRIER INSTALLED PER [R703.5.3] WOOD SIDING OPTIONWOOD SIDING OPTION EXTERIOR PLASTER (STUCCO) OVER CORROSION-RESISTANT LATH OVER (2) LAYERS OF WATER- RESISTIVE BARRIER INSTALLED PER [R703.7] STUCCO OPTIONSTUCCO OPTION CORROSION RESISTANT WEEP SCREED [R703.7.2.1] 2X PRESSURE TREATED SILL PLATE0' - 8 " 1' - 0 " WARM AIR FURNACES INSTALLED IN ATTICS OR FURRED SPACES SHALL BE INSTALLED AS PER UMC 307.3 AND SHALL INCLUDE THE FOLLOWING: 1. A MINIMUM 30"X30" ACCESS (20 FEET MAXIMUM FROM FURNACE) 2.CONTINUOUS SOLID FLOORING (5/8" CDX OR EQ.) 24" MIN. WIDE FROM ACCESS TO FURNACE 3.A LEVEL WORKING PLATFORM 30" MIN. IN DEPTH ALONG THE ENTIRE FIREBOX SIDE OF FURNACE 4. A PERMANENT 110V ELECTRICAL OUTLET AND LIGHTING FIXTURE LOCATED AT OR NEAR FURNACE LIGHTING FIXTURE TO BE CONTROLLED BY A SWITCH LOCATED AT ACCESS. 5.THE FAU SHALL BE LISTED FOR INSTALLATION IN ATTICS AND ON COMBUSTIBLE FLOORING. CLEARANCES SHALL BE AS PER MANUFACTURER'S SPECIFICATIONS AND PER UBC 304. 22" M I N 30" M I N 30" 24" 24" 4 1 2 4 3 5 NOTE: TRUSS DESIGN BY TRUSS MFR. SEE DET. 12/ADI FOR ADDITIONAL INFO. NOTE: VERIFY LENGTH OF PLATFORM W/ HVAC CONTRACTOR SEE DETAIL 12/AD I FOR ADDITIONAL REQUIREMENTS PER UMC 319 1.FRAMING SPAN O/ MIN. 3 TRUSSES, S.S.D. 2.3/4" PLYWD. 3.3/8" GYPSUM BD. AT CEILING F.A.U. 30" X 30" CLR. ACCESS AREA FAU CONTROLS 5'-0" MIN. SEE PLAN 10" CLR. MIN. 3 1 2 HOUSE-R3 1/2" GYPCO. BD. AT INTERIOR OF HOUSE 2X4 (MIN) STUDS AT 16" O.C. (FIRE WALL) 5/8" TYPE "X" GYP. BD. O/ 2X4 FRAME (FRAME PANEL ON FOUR SIDES) 5/8" TYPE "X" GYP.BD. O/ INT. OF GARAGE, TYP. ELECTRIC SUB- PANEL GARAGE - UI AT GARAGE WALL HOUSE - R35/8" TYPE "X" GYP. BD. AT 1-HOUR OCC. SEP. WALL, W.O. 2X4 (MIN.) STUBS AT 16" O.C. (FIRE WALL) 1/2" GYP. BD. O/ 2X4 FLAT FRAME WALL (FRAME PANEL ON FOUR SIDES) ELECTRIC SUB-PANEL HOUSE - R3 AT INTERIOR WALL ELECTRICAL SUB-PANEL ELEVATION 1' - 0 " 2' - 6 " 5' - 4 " ( N T S ) 3 ' - 7 " - CE I L I N G H T . P E R P L A N - TO.S. SCALE: 1" = 1'-0"1 FLASHING AT OPENINGS SCALE: 1" = 1'-0"2 TYPICAL PENETRATION FLASHING SCALE: 1" = 1'-0"3 INSWINGING DOOR SILL AT SLAB SCALE: 1" = 1'-0"4 WATER HEATER SEISMIC BRACE SCALE: 1" = 1'-0"6 TYPICAL HEAD & SILL DETAIL SCALE: 1" = 1'-0"7 EXTERIOR WALL FOOTING SCALE: 1" = 1'-0"8 ACCESS FURNACE AT ATTIC SCALE: 1" = 1'-0"9 FAU PLATFORM SCALE: 3/4" = 1'-0"5 ELECTRICAL SUB-PANEL SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : EM S O C A L E N G I N E E R I N G 24 8 8 1 A L I C I A P K W Y . , ST E . E - 2 2 2 , L A G U N A H I L L S 76 0 - 4 8 4 - 6 3 4 3 AD.1 ARCHITECTURAL DETAILS 10/10/24 61 8 & 6 2 0 W O R I O N AV E . , S A N T A A N A , CA 9 2 7 0 7 NE W D E T A C H E D AC C E S S O R Y DW E L L I N G U N I T RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N PLYWOOD SHEATHING, SSD LAP UNDERLAYMENT MIN. 6" AT RIDGE W/ I CONT. PIECE OF UNDERLAYMENT AT RIDGE S-TILE ROOF TRUSSES, SSD STUD WALL OPERABLE WINDOW EXTERIOR WALL CEILING NOT MORE THAN 44" ABOVE FLOOR ON THE FINISHED SILL HEIGHT 24 " M I N . C L E A R OP E N I N G H E I G H T FLOOR 20" CIR. MINIMUM PLAN VIEW SECTION VIEW 5/8" GYPSUM BOARD WOOD HEADER - SEE STRUCTURAL WOOD CASING, BY OTHERS DOOR, BY OTHERS WOOD DOOR FRAME SHIM, AS REQUIRED 5/8" TYPE "X" GYPSUM BOARD 5/8" GYPSUM BOARD (2) 2X4 WOOD JAMBS WOOD CASING, BY OTHERS DOOR, BY OTHERS WOOD DOOR FRAME SHIM, AS REQUIRED GYP. BD RADIUS CORNER - USE PLASTIC CORNERS AT WET AREAS GYP. BD SEE PLAN FOR FRAMING 2S/1P 1S/2P SHELF POLE SE E P L A N 3' - 0 " 3' - 0 " SE E P L A N 1' - 0 " 0' - 3 " 5' - 6 " 2X4 P.T. CURB ANCHORED TO SLAB 3/8" ANCHOR BOLTS AT 12" O.C., 6" AT ENDS MORTAR BED-SET CERAMIC TILE SLOPE TILE TO DRAIN AT 1/4" PER FOOT HOT MOP SLOPE TO DRAIN AT 1/4" PER FOOT (E) CONCRETE SLAB SCALE: 1" = 1'-0"6 TYPICAL AT RIDGE SCALE: 1" = 1'-0"4 EMERGENCY EGRESS DETAIL SCALE: 3" = 1'-0"2 TYP. WOOD FRAME INTERIOR DOOR HEAD SCALE: 3" = 1'-0"3 TYP. WOOD FRAME INTERIOR DOOR JAMB SCALE: 3" = 1'-0"5 ROUND GYPSUM BOARD CORNER SCALE: 1/2" = 1'-0"7 CLOSET SHELVING SCALE: 3" = 1'-0"1 CURB AT SHOWER ENTRY SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : EM S O C A L E N G I N E E R I N G 24 8 8 1 A L I C I A P K W Y . , ST E . E - 2 2 2 , L A G U N A H I L L S 76 0 - 4 8 4 - 6 3 4 3 AD.2 ARCHITECTURAL DETAILS 10/10/24 61 8 & 6 2 0 W O R I O N AV E . , S A N T A A N A , CA 9 2 7 0 7 NE W D E T A C H E D AC C E S S O R Y DW E L L I N G U N I T RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N 2 12 SD1 TYP 1 SD11 SD1 1 1 SD1 1 1 SD1 1 2 4'-0" 5/8" AB @32" O.C HD U 4 4x 44x 4 HD U 4 2 8'-0" 4x 4 HD U 4 5/8" AB @32" O.C HD U 4 4x 4 2 4' - 0 " 4x4 5/ 8 " A B @3 2 " O . C HDU4 4x4 HDU4 2 4' - 0 " 4x4 5/ 8 " A B @3 2 " O . C HDU4 4x4 HDU4 2 4' - 0 " 4x4 5/ 8 " A B @3 2 " O . C HDU4 4x4 HDU4 5/8" AB @32" O.C 8'-0" 2 4x 4 HD U 4 4x 4 HD U 4 2 4' - 0 " 4x4 5/ 8 " A B @3 2 " O . C 4x4 HDU4 HDU4 4'-0" 4x 4 HD U 4 4x 4 HD U 4 5/8" AB @32" O.C 2 2 4' - 0 " 4x4 5/ 8 " A B @3 2 " O . C 4x4 HDU4 HDU4 SD1 2 2 222 19 SD1 TYP. SD1 3 3 SD1 2 4x4 PBS44 18 SD13 4x4 PBS44 18 SD13 12"x12"x12" PAD FOOTING 12"x12"x12" PAD FOOTING 2 10 ' - 0 " 5/ 8 " A B @3 2 " O . C 4x4 HDU4 4x4 HDU4 SD1 15 LEGENDS : DETAIL SHEAR WALL NAME SHEAR WALL LENGTH NEW FOOTING EXISTING FOOTING X L=X X-X X SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : EM S O C A L E N G I N E E R I N G 24 8 8 1 A L I C I A P K W Y . , ST E . E - 2 2 2 , L A G U N A H I L L S 76 0 - 4 8 4 - 6 3 4 3 S-1 FOUNDATION PLAN 10/25/24 61 8 & 6 2 0 W O R I O N AV E . , S A N T A A N A , CA 9 2 7 0 7 NE W D E T A C H E D AC C E S S O R Y DW E L L I N G U N I T SCALE: 1/4" = 1'-0"1 PROPOSED FOUNDATION PLAN FOUNDATION PLAN NOTES: (N) CONTINUOUS FOOTING 12" WIDTH X 24" DEEP W/(2) #5 REBAR AT TOP AND (2)#5 BOTTOM. (N) NEW 5" CONCRETE SLAB WITH #4 REBAR @16" O.C. OVER 10MIL VISQUEEN OVER 4" BASE OF 1/2" OR LARGER CLEAN AGGREGATE OVER COMPACTED SOIL. NEW 24"X24"X24" DEEP PAD FOOTING W/#4 REBAR @6" O.C. MAX. EA WAY AT BOTTOM 1 2 3 ANCHOR BOLT SCHEDULES: (N) FOOTING: 5/8 X 12" LONG BOLTS @ 48" (U.N.O.) NOTES: -IF MISSING ANCHOR BOLTS THEN DRILL 3/4" X 6" DEEP W/5/8: (RFB#5X10) @32" O.C. WITH SET- XP EPOXY (SPECIAL INSPECTION IS REQUIRED) -SCARIFY TOP 12" OR RE-COMPACT 4" PRIOR TO TRENCHING FOR THE UTILITY AND/OR FOUNDATION. 90% COMPACTION REPORT IS REQUIRED AT THE TIME OF FOUNDATION INSPECTION. PRE-SATURATION SUBGRADE TO 110% OF OPTIMUM MOISTURE CONTENT IS REQUIRED, CODE REQUIREMENT: • • • • • • • THIS PROJECT SHALL COMPLY WITH THE: 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBSC) 2022 CALIFORNIA ENERGY EFFICIENCY STANDARDS (CEES) 2022 CALIFORNIA BUILDING CODE (CBC) FOUNDATION NOTES: 1. A. B. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. FOUNDATION HAS BEEN DESIGNED ASSUMING MIN. ALLOWABLE SOIL BEARING PRESSURE. (SEC. 1802.6) SHALL BE AS FOLLOWS: CONTINUOUS FOOTING : 1500 SF ISOLATED FOOTING: 1500 SF CONCRETE SHALL HAVE A MIN. COMPRESSIVE STRENGTH (fC) OF 3,000 psi WATER ALL FOOTING SHALL BE POURED ON OR BELOW FIRM UNDISTURBED NATURAL SOIL OR APPROVED COMPACTED FILL AND ADJACENT FINISH GRADE U.N.O. ALL FOOTING SHALL BE CENTERED ON PILATER AND OR WALL AND COLUMN U,N.O. ALL EXISTING FILL SOIL AND DISTRUBED NATURAL SOILS ARE TO BE EXCAVATED AND REPLACED WITH PROPERLY COMPACTED FILL. ALL FILLING, BACKFILLING, RECONNECTION, ETC. IS TO BE ACCOMPLISHED ONLY UNDER THE SUPERVISION OF A SOIL ENGINEER, COMPACTED FILL SHALL BE 95% DENSITY PROVIDE MIN. 5/8" X 12" ANCHOR BOLTS WITH 3"X3"1/4" WASHERS, EMBEDDED 7" MIN. INTO CONCRETE OR MASONRY AND SPACE MAX. 48" O.C. PROVIDE MIN. 2 BOLTS PER PLATE AND NOT MORE THAN 12" OR LESS THAN 4" OR PLATE END AND CORNER. (CHAPTER 4 CRC) FASTENERS FOR PRESERVATIVE-TREATED SHALL BE HOT DIPPED ZINC-COATED GLAVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER IN ACCORDANCE WITH ASTM A 153(R317.3) FOUNDATION SILL PLATE SHALL BE NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. FIELD-CUT ENDS, NTOCHES AND DRILLED HOLES OR PRESERVATIVE TREATED WOOD SHALL BE FIELD-REATED PER AWPA M4.(R317.1.1).\ ALL REINFORCING STEEL SHALL BE MIXED AND DELIVERED IN ACCORDANCE WITH ASTM C-94 ALL EXISTING UTILITIES THAT INTERFERE WITH THE STRUCTURAL FOUNDATIONS SHALL BE REMOVED AND RELOCATED THE CONTRACTOR WILL BE SOLELY RESPONSIBLE FOR ALL EXCAVATION PROCEDURES INCLUDING LAGGING, SHORING, AND PROTECTION OF ANY ACCORDANCE WITH ALL NATIONAL STATED AND LOCAL SAFETY ORDINANCE READY MIX CONCRETE SHALL BE MIXED AND DELIVERED IN ACCORDANCE WITH ASTM C-94 ALL REINFORCING STEEL, ANCHOR BOLTS, DOWELS, AND OTHER INSERTS SHALL BE SECURED IN POSITION AND INSPECTED BY THE LOCAL BUILDING OFFICIAL PRIOR TO THE PLACING OF ANY CONCRETE MINIMUM SLAB REINFORCEMENT AND PAD REQUIREMENTS SHALL CONFORM TO THE SOILS ENGINEER'S RECOPMMENDATIONS UNLIES NOTED OTHERWISE PROVIDE A MIN. 26-GAGE WEEP SCREED FOR STUCCO AT THE FOUNDATION PLATE LINE A MINIMUM O F6" ABOVE EARTH OR 4" ABOVE PACED AREA. (R703.6.2.1) WOD SILL PLATE SHALL BE MINIMUM 8" ABOVE ADJACENT GRADE (R317.1) STRUCTURAL DESIGN DATA: VERTICAL LOADS: DEAD(DL) LIVE(LL) ROOF LOAD:7 PSF 20 PSF CEILING LOAD:5 PSF 10 PSF EXT. WALL LOAD:17 PSF INT. WALL LOAD:7 PSF WIND DESIGN DATA: BASIC WIND SPEED:110MPH WIND EXPOSURE:B EARTHQUAKE DESIGN DATA: IMPORTANCE FACTORE:1=1.0 MAPPED Ss = 1.394 AND Si = 0.493 SITE CLASS: D SEISMIC DESIGN CATEGORY: D BASIC SEISMIC-FORCE-RESISTING SYSTEM = BWS RESPONSE MODIFICATION FACTOR, R = 6.5 SEISMIC RESPONSE COEFFICIENT, Cs = 0.172 ANALYSIS PROCEDURE USED:EQUIVALENT SOIL DATA: ASSUME ALLOWABLE SOIL BEARING 1,500 PSI RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N 2X 6 C J @ 1 6 " O C 2X10 RIDGE 4X6 HEADER SD1 9,11 SD1 6 SD1 4 2X 6 c j @ 1 6 " O C 2X 6 R R @ 1 6 " O C 4X6 HEADER SD1 6 SD1 6 SD1 10 4X6 HEADER 4X6 HEADER 4X 6 H E A D E R 4X 6 H E A D E R 4X 6 H E A D E R 4X 6 H E A D E R 4X 6 H E A D E R 4X6 HEADER 4X6 HEADER 4X6 HEADER4X 6 H E A D E R 4X 6 H E A D E R SD1 6 4X 6 H E A D E R 4X6 HEADER 4X6 HEADER 6x10 BEAM 2X 6 C J @ 1 6 " O C 2X 6 c j @ 1 6 " O C 2X 6 R R @ 1 6 " O C 2X 6 R R @ 1 6 " O C 2X 6 R R @ 1 6 " O C 2 4'-0" 2 8'-0" 2 4' - 0 " 2 4' - 0 " 2 4' - 0 " 8'-0" 2 2 4' - 0 " 4'-0" 2 2 4' - 0 " 2 8' - 0 " 4X4 POST 4X4 POST 2X10 RIDGE 4x6 BM 4x6 BM 2X6 CJ & RR @16" OC RR CJ 2-2x6 PR DRAG STRAP TO SHEARWALL WITH 2-MSTA 36 SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : EM S O C A L E N G I N E E R I N G 24 8 8 1 A L I C I A P K W Y . , ST E . E - 2 2 2 , L A G U N A H I L L S 76 0 - 4 8 4 - 6 3 4 3 S-2 FRAMING PLAN (ADU) 10/25/24 61 8 & 6 2 0 W O R I O N AV E . , S A N T A A N A , CA 9 2 7 0 7 NE W D E T A C H E D AC C E S S O R Y DW E L L I N G U N I T SCALE: 1/4" = 1'-0"1 PROPOSED FRAMING PLAN 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 1. ALL NAILING SHALL BE COMMON NAILS. MAXIMUM STUD SPACING SHALL BE 16" O.C. ALL PANEL EDGES SHALL BE BLOCKED. FRAMING MEMBER SHALL INCLUDE SILL PLATES AND ALL FRAMING MEMBERS RECEIVING EDGE NAILING FROM ABUTTING PANELS EDGE NAILING ON 3X MEMBERS SHALL BE STAGGERED PLYWOOD FOR FORIZONTAL DIAPRAGHMS SHALL BE MADE WITH EXTERIOR GLUE (CHAPTER 4 CRC) USE 3X3X1/4" CUT PLATE WASHER AT ALL ANCHOR BOLTS SHALL BE PRESSURE TREATED. (CHAPTER 4 CRC) FASTENER FOR PRESERVATIVE-TREATED SHALL BE HOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER AT EXISTING FOOTINGS, USE RFB#DX12 HDG-R SIMPSON RETROFIT BOLTS WITH SETXP-EPOXY ICC #ESR-2508. SPECIAL INSPECTION REQUIRED. SECOND-FIGURE INDICATES WHERE SHEAR WALL SHEATHING IS TO BE APPLIED TO BOTH SIDES OF WALL AT EXISTING CONDITION, 2X SILL PLATE MAY BE USED WITH 3X SILL ADDES AND 5/8" ⌀ A.B. @ 16" O.C. FOR SHEARWALL #2 ONLY. ALL STRUCTURAL LUMBER SHALL BE DOUGLAS FIR-LACH, MAX. MOISTURE CONTENT SHALL NOT EXCEED 19% OF THE FOLLOWING FRADES UNLESS NOTED OTHERWISE: REPETITIVE USE MEMBERS: STUDS, JOISTS, AND RAFTERS 2X AND 4X NO.2 SINGLE USE MEMBERS: BEAM 4X NO.2 6X OR LARGER NO. 1 POSTS AND MULLIONS 4X AND SMALLER NO.2 6X AND LARGER NO.1 MISCELLANEOUS LUMBERS" BLOCKING, FURRING. ETC NO.2 DECKING AND SHEATHING 2X, 3X AND 4X COMM'L EX. 2.ALL STRUCTURAL LUMBER SHALL BE GRADE IN ACCORDANCE WITH GRADING AND DRESSING RULES #16 OF THE WEST COAST LUMBERMAN'S ASSOCIATION. 3.ALL STRUCT'S PLYWOOD SHALL BE IN ACCORDANCE WITH P.S. 1-74 MANUFACTURED PRODUCTS 1.GLUED-LAMINATED BEAMS DOUGLAS FIR-LACH INDUSTRIAL APPEARANCE WITHIN EXTERIOR GLUE U.N.O. 16F-V3 DF/DF (Fb=16000 psi, Fv=190 Psi, E=1.5 E6 psi 24F-V4 DF/DF (Fb=2400 psi, Fv=240 Psi, E=1.8 E6 psi), ICC ESR-1940 2.DESIGN VALUES FOR MANUFACTURED PARALLAM PSL SHALL BE MIN. Fb=2900 psi, Fv= 290psi, E=2.0 E6psi, ICC ESR-1387 3.DESIGN VALUES FOR MANUFACTURED MICROLAM LVL SHALL BE MIN. Fb=2600 psi, Fv= 285 psi, E=1.9 E6 psi, ICC ESR-1387 WOOD POSTS EXPOSED TO WEATHER OR WATER SHALL BE 1" ABOVE A SLAB AND 6" ABOVE GRADE OR 8" ABOVE GRADE. [CRC R317.1.4] NOTES: WOOD FRAMING NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS ALL INTERIOR SHEARWALL SHALL EXTEND TO THE ROOF OR FLOOD DIAPHRAGM LEVEL DOUBLE JOISTS ARE REQUIRED UNDER PARALLEL BEARING PARTITIONS PROVIDE CONTINUOUS BLOCKING BETWEEN FLOOR JOISTS UNDER ALL BEARING WALLS. TOP PLATE BREAKS ARE SHALL OCCUR OVER A STUD OR POST. DOUBLE TOP PLATES SPLICE WITH MIN. 48" LAP AND PROVIDED WITH MIN. 8-16d NAILS PER TOP PLATE SPLICE WHERE BOTH TOP PLATES ARE BROKEN, SHALL BE STRAP BOTH SIDES WITH ST6224 U.N.O. ALL POSTS SHALL HAVE CONNECTIONS AT TOP AND BOTTOM WHICH SHALL BE SIMPSON "CCQ", "CBSQ" UNLESS SPECIFICALLY DETAILED OTHERWISE. FOR POSTS IN POCKES AND IN FRAMED WALLS THE COLUMN CAP AND BASE MAY BE ELIMINATED UNLESS DETAILED ON THE DRAWINGS. ALL FREE STANDING POSTS SHALL USE SIMPSON "CCQ", "ECCQ" AND "CBSQ" CONNECTORS U.N.O. ON PLANS. USE SIMPSON "HU" HANGERS ON ALL JOIST OR BEAM CONNECTIONS, UNLESS NOTED OTHERWISE ON PLANS ALL HANGING JOISTS SHALL BE HUNG WITH SIMPSON "LUS" HANGERS U.N.O. AND SIMPSON "ITT" HANGER FOR TJI'S U.N.O. ALL NON-BEARING BALLOON FRAMED WALLS EXCEEDING 14'-0" IN HEIGHT AND NOT SUPPORTED BY CEILING JOIST AT EITHER SIDE SHALL BE FRAMED WITH 2X6 STUDS @16" O.C. (NOT EXCEED 20'-0") PER CHAPTER 6 CRC FASTENING OF MULTIPLE MEMBERS: DOUBLE & TRIPLE JOISTS; 16d @ 12" O.C. STAGGERED (BOTH SIDES FOR TRIPPLES_ FOUR OR MORE JOISTS SHALL BE BOLTED TOGETHER WITH 1/2" BOLTS AT 18" O.C. STAGGERED. RE-TIGHTEN BOLTS PRIOR TO APPLYING FINISH MATERIAL. SHEAR WALL SCHEDULE MARK SHEAR (PLF)MATERIAL (1)(6) NAILS AT SPACING OF BN, EN, FN (2) NAILS AT SPACING OF EN, FN (2) TOP PLATE FRAMING CONNECTOR (2) SILL PLATE NAILS TO BLOCKING BELOW (2)(6) ANCHOR B. SPACING 1 2 260 380 15/32" CDX (ID# 24/0)(ONE SIDE) 15/32" CDX (ID# 24/0)(ONE SIDE) 8d @ 6,6,6 8d @ 4,4,6 8d @ 6:6 8d @ 4:6 A35 @ 24" O.C. OR 16d @ 6" O.C. A35 @ 12" O.C. OR 16d @ 6" O.C. 16d @ 4" O.C. 16d @ 4" O.C. 48" 36" NOTE ON PLAN:NOTE ON PLAN: WHERE PANELS ARE APPLIED ON BOTH FACES OF A SHEARWALL AND NAIL SPACING IS LESS THAN 6 INCHES ON CENTER ON EITHER SIDE, PANEL JOISTS SHALL BE OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS. ALTERNATIVELY, THE WIDTH OF THE NAILED FACE OF FRAMING MEMBERS SHALL BE 3" OR GREATER AT ADJOINING PANEL EDGES AND NAILS AT ALL PANELS EDGES SHALL BE STAGGERED. RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N 8" M I N PE R S C H E D U L E 4 3 5 D 6 2 2 MIN. 6" DOWEL INTO FOOTING 1 2 3 4 5 6 REBAR (SEE FOOTING SCHEDULE) MIN. 5" THK. CONC. SLAB W/ #4 REBAR @16 O.C. OVER 10MIL. VISQUEEN OVER 4" BASE OF 1/2 OR LARGER CLEAN AGGREGATE OVER COMPACTED SOIL 5/8" DIA.. A.B @32" OC (U.N.O) EMBED MIN. 7" INTO SLAB W/ 3x3x0.229" PLATE WASHER W/ 2x P.T. SILL U.N.O SHEAR WALL WHERE OCCURS WEEP SCREED 2x STUDS @16" O.C #3 TIE @48" O.C. W/ STANDARD HOOK @EA. END FOR 2 POURS SLAB 2"CONCRETE/PAVE 4" SOIL FIN. GRADE 3" M I N . 24" @ 18" O.C.6" PER SCHEDULE 24". DOWELS @ 18" O.C.6" . PE R S C H E D U L E 4 3 5 2 1#3 TIE @48" O.C W/ STANDARD HOOK @EA. END FOR 2 POURS SLAB 1 2 3 4 5 REBAR (SEE FOOTING SCHEDULE) MIN. 5" THK. CONC. SLAB W/ #4 REBAR @16 O.C. OVER 10MIL. VISQUEEN OVER 4" BASE OF 1/2 OR LARGER CLEAN AGGREGATE OVER COMPACTED SOIL 5/8" DIA.. A.B @32" OC (U.N.O) EMBED MIN. 7" INTO SLAB SHEAR WALL WHERE OCCURS 2x STUDS @ 16" O.C. 3" M I N . PER SCHEDULE DOUBLE TOP PLATED SIMPSO N STRAP LSTA24 SIMPSON PER PLAN HEADER OR BEAM PER PLANS POST/KP PER PLANS SIMPSON STRAP LSTA24 KING POST PER PLAN HEADER PER PLAN SIMP. A35 BEAM PER PLAN BEAM PER PLANS SIMPSON A35 DOUBLE TOP PLATE SIMP. A35 SLOPE CUT WHERE OCCURS 1/2" OSB ROOF SHEATHING 2x ROOF RAFTER STUD WALL TOP PLATE 2x FASCIA SHIP LAP 2x BLOCKING E.N. 8-16d NAILS C.J TO R.R CEILING JOIST PER PLAN A35 @16" OC U.N.O. CEILING JOIST PARALLEL TO ROOF JOIST SHEAR WALL WHERE OCCURS EQ EQ 45° M I N . 2x4 KICKER @4' MAX.OCSIMPSON A35 (2) SIMPSON A35 E.A R.R SIMPSON LSTA24 STRAP @32" O.C C.J PER PLANS BEARING WALL PER PLANS OVERLAP 12" MIN. W/(10) 16D NAIL WOOD BEAM PER PLAN WOOD POST PER PLAN SIMPSON "ECCQ" CAP B A WOOD BEAM PER PLAN WOOD POST PER PLAN SIMPSON "ECCQ" CAP EQ EQ 2x4 KICKER @ 4' MAX.OC SIMPSON A35 PROVIDE (2) A35 @ E.A RAFTER TO RIDGE SIMPSON LSTA24 STRAP @32" O.C 45° M I N . FLUSH BEAM OR WALL PER PLAN C.J PER PLANS CONTINUOUS TOP PLATE HEADER PER PLAN SIMP. ST 18 ONE SIDE POST PER PLAN EQ EQ PROVIDE (2) A35 @ EA. RAFTER TO RIDGE SIMPSON LSTA24 @32" O.C 2x4 COLLAR TIE @32"O.C. 3-10d NAILS 1. 2x4 STUDS @ 16"O.C. 2. 2X P.T.D.F. PLATE WITH 0.18"DIA. x 3" SHOT PINS @32" O.C. WITH 14GA GAGE WASHERS & FIRST 2 PINS PLACED 6" & 10" FROM PLATE ENDS ICC# ESR-1799 (RAMSET) LARR #22668 3. CONCRETE SLAB 4. 1/2" DRYWALL 4 123 1. NOTCH IN PLATE 2. 1 3/4" MAX. IF BORED HOLE EXCEED 1 3/4" IN 2x4 TOP PLATE OR 2 3/4" IN 2x6 TOP PATE, STRAP E/S OF PLATE W/ITEM #3 BELOW 3. SIMPSON CS 1 6x4" LONG METAL STRAP, TYPICAL @ EACH PLATE CUT W/(6) 16d's EACH SIDE. 4. PIPE WHERE OCCURS 5. TOP PLATES-SILL PLATES 6. ANCHOR BOLTS PER PLANS 7. LOCATE ANCHOR BOLT 5" MIN. 9" MAX. AWAY FROM NOTCH OR END OF PLATE NOTE: IF NOTCH OR HOLE EXCEEDS 50% OF TOP PLATE WIDTH, USE SIMPSON ST6224, STAGGERED @ E/S OF PLATES, USE SIMPSON NS AS NEEDED. 4345 1 2 5 37 DEPT H 1/2 DEPTH 3" MAX. 1. NOTCH DEPTH & BORED HOLD SEE TABLE BELOW. 2. STUD 3. STILL PLATE 4. HOLE EDGE DISTANCE 5/8" MIN. NOTE: BORED HOLES NOT PERMITTED IN MORE THAN TWO CONSECUTIVE DOUBLE STUDS BORED HOLES STUD SIZE EXTERIOR & BEARING WALLS NON- BEARING WALLS 2x4 2x6 2-2x4 2-2x6 % 1 7/16" 2 1/8" 40% 2 1/8" 2 1/8" 60% 2 3/16" 3 5/16" 3 5/16" 3 5/16" STUD SIZE EXTERIOR & BEARING WALLS NON- BEARING WALLS NOTCH DEPTH 2x4 2x6 % 7/8"1 7/16" 1 3/8"2 3/16" 25%40% 1 4 2 3 4 1 d MIN. PER SCHEDULE 3" M I N . PE R S C H E D U L E 2% SLOPE MIN. 1 2 3 4 REBAR (SEE FOOTING SCHEDULE) MIN. 5" THK. CONC. SLAB W/ #4 REBAR @16 O.C. OVER 10MIL. VISQUEEN OVER 4" BASE OF 1/2 OR LARGER CLEAN AGGREGATE OVER COMPACTED SOIL 1/2" FIBER BOARD EXPANSION JOINT MIN. 4" THK. CONC. SLAB W/ #3 REBARD @18" O.C O/ COMPACTED SOIL 234 1 24". 6" . FOUNDATION EMBED REQUIREMENT SHALL BE FROM THE LOWEST ADJACENT GRADE ANCHOR BOLTS (AB) SHALL BE 5/8" WITH 3"X3'X0.229" THICK PLATE WASHERS. SPACING OF ANCHOR BOLTS SHALL NOT EXCEED 6'-0" O.C. EACH SECTION OF PLATE SHALL HAVE A MINIMUM OF TWO AB. ANCHOR BOLTS SHALL BE EMBEDDED A MINIMUM OF 7" INTO FOOTING. HOLES SHALL BE 1/32" TO 1/6" LARGER THAN AB. LARGER HOLES SHALL BE REPAIRED WITH EPOXY. PLATES SHALL BE PRESSURE TREATED DOUGLAS FIR NOT HEM-FIR. 12 " M A X . 5" M I N . 12" MAX 5" MIN. 12 " M A X 5" M I N . 12" MAX 5"MIN. 12" MAX 5" MIN 2" M A X AB SPACING 6' MAX OR PER SHEAR WALL SCHEDULE (TYP) PANEL PER PLAN (TYP.) AT CORNER AT INTERSECTION AT SPLICE TRUSS WHERE OCCURS PER PLAN SIMPSON "DTC" @48" O.C. MAX. 2X BLK'G. @48" O.C. W/ (3) 16d'S @ EA.END JOIST OR TRUSS BOTT. CHORD 1X OVER 2X PLATE3/ 4 " T Y P . NON-BRG. WALL WOOD POST PER PLAN CONCRETE SLAB PER PLAN VAPOR BARRIER IN DIRECT CONTACT W/ CONC. SLAB PER ARCH. PLANS 4" THICK BASE OF 1/2" OR LARGER CLEAN AGGREGATEMI N . 1' - 6 " CL R . 0' - 3 " REINFORCING PER PLAN CONT. FT'G BEYOND SIMPSON CP PER PLAN COLUMN BASE SCHEDULE CB44 W/2-1/2" DIA.. M.B. FOR 4x4 POST CB46 W/2-5/8" DIA.. M.B. FOR 4x6 POST CB66 W2-5/8" DIA.. M.B. FOR 6x6 POST CB88 W/2-3/4" DIA.. M.B. FOR 8x8 POST SEE PLAN 0' - 8 " 1' - 0 " 1' - 0" CBSQ POST BASE, INSTALL PER MANUFACTURES SPECIFICATIONS CONCRETE SLAB WHERE OCCURS UNDISTURBED NATURAL GRADE POST PER PLAN 12" SQUARE CONCRETE PIER FOUNDATION EMBED REQUIREMENT SHALL BE FROM THE LOWEST ADJACENT GRADE 1-3/4" EDGE DIST. EQEQ 3" - 5 " 3" M I N . MI N . E M B E D M E N T "l e " 3" - 4" POST PER PLAN (4x MIN.) FASTENERS PER MANUF. SIMP. HOLDOWN PER PLAN (PHD SHOWN) #4 CONT. REBAR 2x, 2-2x OR 3x P.T.D.F. SILL P PER PLAN L SIMPSON "SSTB" PER SCHEDULE CONT. FTG. OR FDN. WALL SEE OTHER DETAIL FOR SIZE & REINF. . DEEPEN FTG. AS REQ'D. TO MAINTAIN A.B. CLEARANCE (12"x12" MIN. IN PLAN) NOTES: 1. FOR RAISED FOUNDATION USE SSTB FOR TWO POUR SYSTEM AND EXTEND BOLT BEYOND SILL PLATE ABOVE FLOOR SHEATHING, OR USE SIMP. CNW COUPLER FOR BOLT EXTENSION. 2. CONCRETE STEM WALLS SHALL BE 6"MIN WIDTH FOR 5/8⌀ ANCH., 8" MIN. WIDTH FOR 7/8"⌀ ANCH., 8" MIN. FOR CONC. BLK 3. VALUES BASED ON GOVERNING CAPACITY OF SSTB AT END OF CONC. WALL CONDITION (ICC#: ESR-2611) SCHEDULE SCHEDULE HDU2-SDS2.5 HDU4-SDS2.5 HDU5-SDS2.5 HDU8-SDS2.5 16 20 24 28 34 24 24 24 34 34 4x4 4x4 4x4 4x4 4x6 6-SDS 10-SDS 14-SDS 20-SDS 20-SDS # SDS SCREWS (1/4"⌀) MIN. POST EMBEDMENT "le" SSTB # 1-POUR SSTB # 2- POUR SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : EM S O C A L E N G I N E E R I N G 24 8 8 1 A L I C I A P K W Y . , ST E . E - 2 2 2 , L A G U N A H I L L S 76 0 - 4 8 4 - 6 3 4 3 SD1 STRUCTURAL DETAILS 10/10/24 61 8 & 6 2 0 W O R I O N AV E . , S A N T A A N A , CA 9 2 7 0 7 NE W D E T A C H E D AC C E S S O R Y DW E L L I N G U N I T WOOD POST TO WOOD BEAM CONNECTION DETAIL WOOD POST BASE TO PAD DETAIL 0301NEW EXTERIOR FOOTING 02NEW INTERIOR FOOTING 04FLUSH BEAM TO POST CONNECTION 05KING POST TO HEADER 06RAFTER AT EXTERIOR WALL 07RIDGE SUPPORTING 08 09BEAM-CEILING JOIST-RIDGE CONNECTION 10HEADER TO POST 11FLUSH RIDGE 12NON-BEARING INT. WALL TYP., N.T.S.13PIPING THRU PLATE FRAMING, N.T.S.14FLUSH BEAM TO POST CONNECTION 15PORCH TO HOUSE FOOTING 16TYPICAL PLATE ANCHOR BOLTS 17INTERIOR WALL 18EXTERIOR POST FOOTING RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N 19HOLD DOWN DETAIL SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : EM S O C A L E N G I N E E R I N G 24 8 8 1 A L I C I A P K W Y . , ST E . E - 2 2 2 , L A G U N A H I L L S 76 0 - 4 8 4 - 6 3 4 3 T24 T24 01/14/25 61 8 & 6 2 0 W O R I O N AV E . , S A N T A A N A , CA 9 2 7 0 7 NE W D E T A C H E D AC C E S S O R Y DW E L L I N G U N I T RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : EM S O C A L E N G I N E E R I N G 24 8 8 1 A L I C I A P K W Y . , ST E . E - 2 2 2 , L A G U N A H I L L S 76 0 - 4 8 4 - 6 3 4 3 CG.1 CAL. GREEN REQUIREMENTS 10/10/24 61 8 & 6 2 0 W O R I O N AV E . , S A N T A A N A , CA 9 2 7 0 7 NE W D E T A C H E D AC C E S S O R Y DW E L L I N G U N I T RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : EM S O C A L E N G I N E E R I N G 24 8 8 1 A L I C I A P K W Y . , ST E . E - 2 2 2 , L A G U N A H I L L S 76 0 - 4 8 4 - 6 3 4 3 CG.2 CAL GREEN REQUIREMENTS 10/10/24 61 8 & 6 2 0 W O R I O N AV E . , S A N T A A N A , CA 9 2 7 0 7 NE W D E T A C H E D AC C E S S O R Y DW E L L I N G U N I T RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N EL ORION AVENUEORION AVENUE 618 W ORION AVE., SANTA ANA, CA PR O P E R T Y L I N E PR O P E R T Y L I N E 11 2 . 5 0 ' 93 . 3 8 ' (E) SINGLE FAMILY DWELLING PROPERTY LINE56.00' 11 2 . 5 0 ' 93 . 3 8 ' 4:12 4:12 4: 1 2 41.27' PRO P E R T Y L I N E - F R O N T A G E 18.37' (N) 800 SF ACCESSORY DWELLING UNIT FIRE SEPARATION DETAIL LINE (E) CONCRETE DRIVEWAY (E) DRIVEWAY APRON (E) FENCE (E) FENCE (E) WALKWAY (E) WALKWAY (E) WALKWAY E D C B B 4: 1 2 FUTURE SOLAR PANEL 4:12 4:12 PUBLIC UTILITY EASEMENT 5' - 0 " 620 W ORION AVE., SANTA ANA, CA 5-GALLON SHRUB 24-INCH CANOPY TREE 1-GALLON SHRUB 1-GALLON SHRUB 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. EROSION CONTROL IS REQUIRED FOR GRADING OPERATIONS DURING THE RAINY SEASON FROMOCTOBER 15TH TO APRIL 15TH. APPROVED PLANS ARE REQUIRED FOR ALL ROUGH GRADING. IN CASE OF EMERGENCY, CALL: ORCHID L & HAN NGUYENT AT (714) 417 32023. THE DESIGN CIVIL ENGINEER WILL SUPERVISE EROSOIN CONTROL WORK AND ENSURE THAT WORK IS IN ACCORDANCE WITH THE APPROVED PLANS (IF REQUIRED). EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON.NECESSARY MATERIALS SHALL BE AVAILABLE ON SITE ANDSTOCKPILED AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARYDEVICES WHEN RAIN IS IMMINENT. DEVICES SHALL NOT BE MOVED OR MODIFIED WITHOUT THE APPROVAL OF THE CITY ENGINEER. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE 5.DAYS RAIN PROBABILITY FORECAST EXCEEDS 40%. AFTER A RAINSTORM, ALL SILT AND DEBRIS SHALL BE REMOVED FROM CHECK GRADED AREAS AROUND THE TRACK PERIMETER MUST DRAIN AWAY FROM THE FACE OF SLOPE THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS WHERE IMPOUNDED WATER CREATES A HAZARDOUSCONDITION. DESILTING BASINS ARE TO BE CONSTRUCTED AS GRADING OF INDIVIDUAL GRADING AREAS ARECOMPLETE PER ROUGH GRADING PLANS. THE CITY ENGINEER RESERVES THE RIGHT TO MAKE CHANGES OR MODIFICATIONS TO THIS PLANAS DEEMED NECESSARY. INFORMATION IN THIS PLAN IS FOR EROSION CONTROL ONLY.ALL OTHER INFORMATION ISSUBJECT TO CHANGE. TEMPORARY EROSION PROTECTION IS REQUIRED FOR MANUFACTURED SLOPES PRIOR TOPERMANENT PLANTING. AREAS SHALL BE MAINTAINED IN SUCH A STATE THAT FIRE ACCESS SHALL SEE MAINTAINED ATALL TIMES (INCLUDING ACCESS TO NEIGHBORING PROPERTIES). NO OBSTRUCTION OR DISTURBANCE OF NATURAL DRAINAGE COURSES OR EXISTING STORMDRAIN INLETS SHALL OCCUR DURING THE RAINY SEASONS, UNLESS ADEQUATETEMPORARY/PERMANENT DRAINAGE FACILITIES HAVE BEEN APPROVED AND INSTALLED TOCARRY SURFACE WATER TO THE NEAREST PRACTICAL STREET, STORM DRAIN OR NATURALWATER COURSE. THE CONTRACTOR SHALL CONDUCT HIS OPERATIONS IN SUCH A MANNER THAT STORM RUNOFF WILL BECONTAINED WITHIN THE PROJECT OR CHANNELS INTO THE STORM DRAIN SYSTEM WHICH SERVES THE RUNOFF AREA.STORM RUNOFF FROM ONE ARE SHALL NOT BE ALLOWED TO DIVERT TO ANOTHER RUNOFF AREA. CONFORMANCE WITH THE REQUIREMENT OF THESE PLANS SHALL IN NO WAY RELIEVE THE CONTRACTOR FROMHIS RESPONSIBILITIES TO THIS SITE AND ADJACENT PROPERTIES. TEMPORARY EROSION CONTROL SHALL CONSIST OF,BUT NO TO BE LIMITED TO, CONSTRUCTING SUCH FACILITIES AND TAKING SUCH MEASURES AS ARE NECESSARY TOPREVENT, CONTROL AND ABATE WATER, MUD AND EROSION DAMAGE TO PUBLIC AND PRIVATE PROPERTY AS ARESULT OF THE CONSTRUCTION OF THIS PROJECT. SLOPES CONSTRUCTED PRIOR TO OCTOBER 1 SHALL BE TREATED FOR EROSION CONTROL PRIOR TO OCTOBER15. SLOPES CONSTRUCTED AFTER OCTOBER 1 SHALL BE TREATED FOR EROSION CONTROL AS THE CONSTRUCTION OFSLOPE PROGRESS IN INCREMENT OF 25 FEET OR LESS MEASURES VERTICALLY. FILL AREAS WHILE BROUGHT UP TO GRADE AND DURING PERIODS OF COMPLETION PRIOR TO FINAL GRADE,SHALL BE PROTECTED BY VARIOUS MEASURES TO ELIMINATE EROSION AND THE SILTATION OF DOWNSTREAMFACILITIES AND ADJACENT AREAS. THESE MEASURES MAY INCLUDE, BUT SHALL NOT BE LIMITED TO: TEMPORARYDOWNDRAINS, EITHER IN THE FORM OF PIPES OR PAVED DITCHES WITH PROTECTED OUTFALL AREAS; GRADED BERMSAROUND AREAS TO ELIMINATE EROSION OF FILL SLOPES BY SURFACE RUNOFF, CONFINED PONDING AREAS TO DESILTRUNOFF; TEMPORARY CHECK DAMS IN TOE OF SLOPE DITCHES TO DESILT RUNOFF; PROTECTION SUCH AS SANDBAGS AROUND INLETS WHICH HAVE NOT BEEN BROUGHT UP TO GRADE, AND EARTH BERMS AND APPROPRIATEGRADING TO DIRECT DRAINAGE AWAY FROM THE EDGE OF THE SLOPES SHALL BE CONSTRUCTED AND MAINTAINED ONTHOSE FILL AREAS WHERE EARTH-WORK OPERATIONS ARE NOT IN PROGRESS. TOP OF CUT BROW DITCHES, WHERE REQUIRED ON THE PLANS, SHALL BE CONSTRUCTED PRIOR TO EXCEEDING12 FEET OF CUT MEASURED VERTICALLY. CLEARING AND GRUBBING SHOULD BE LIMITED TO AREAS THAT WILL RECEIVE IMMEDIATE GRADING. EROSION CONTROL MEASURES WILL BE REQUIRED TO PROTECT AREAS THAT HAVE BEEN CLEARED AND GRUBBED PRIOR TOGRADING OPERATION, AND THAT ARE SUBJECT TO RUNOFF DURING THE PERIOD FROM THE BEGINNING OF THE RAINYSEASON. THESE MEASURES MAY INCLUDE BUT SHALL NOT BE LIMITED TO: GRADED DITCHES; BRUSH BARRIERSAND SILT FENCES. CARE SHALL BE EXERCISED TO PRESERVE VEGETATION BEYOND THE LIMITS OF GRADING. CITY APPROVAL OF PLANS DOES NOT RELIEVE THE DEVELOPER FROM RESPONSIBILITY FOR THE CORRECTIONOF ERRORS AND OMISSIONS DISCOVERED DURING CONSTRUCTION. UPON REQUEST, THE REQUIRED PLAN REVISIONSSHALL BE PROMPTLY TO THE CITY ENGINEER FOR APPROVAL. EROSION CONTROL GENERAL NOTES: SCALE: 1/8" = 1'-0"1 EROSION & SEDIMENT CONTROL PLAN SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : EM S O C A L E N G I N E E R I N G 24 8 8 1 A L I C I A P K W Y . , ST E . E - 2 2 2 , L A G U N A H I L L S 76 0 - 4 8 4 - 6 3 4 3 A6 EROSION & SEDIMENT CONTROL PLAN 10/10/24 61 8 & 6 2 0 W O R I O N AV E . , S A N T A A N A , CA 9 2 7 0 7 NE W D E T A C H E D AC C E S S O R Y DW E L L I N G U N I T RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N EL ORION AVENUEORION AVENUE 618 W ORION AVE., SANTA ANA, CA PR O P E R T Y L I N E PR O P E R T Y L I N E 11 2 . 5 0 ' 93 . 3 8 ' (E) SINGLE FAMILY DWELLING PROPERTY LINE56.00' 11 2 . 5 0 ' 93 . 3 8 ' 4:12 4:12 41.27' PROP E R T Y L I N E - F R O N T A G E 18.37' G (E) CONCRETE DRIVEWAY (E) DRIVEWAY APRON (E) FENCE (E) FENCE (E) WALKWAY (E) WALKWAY 34.6' 34.0' 34.4' 34.0' 33.4 32.4' WM (E) TRELLIS (TO BE REMOVED) PUBLIC UTILITY EASEMENT 5' - 0 " 34' - 8" 15 ' - 5 " 10' - 4"11' - 0" ORION AVENUEORION AVENUE 618 W ORION AVE., SANTA ANA, CA PR O P E R T Y L I N E PR O P E R T Y L I N E 11 2 . 5 0 ' 93 . 3 8 ' (E) SINGLE FAMILY DWELLING PROPERTY LINE56.00' 11 2 . 5 0 ' 93 . 3 8 ' 4:12 4:12 4: 1 2 41.27' PROP E R T Y L I N E - F R O N T A G E 18.37' (N) 800 SF ACCESSORY DWELLING UNIT G FIRE SEPARATION DETAIL LINE (E) CONCRETE DRIVEWAY (E) DRIVEWAY APRON (E) FENCE (E) FENCE (E) WALKWAY (E) WALKWAY (E) WALKWAY 5% 2% 2% 5% 5% 5% 5% 2%2% 5% 5% 5% 2% 5% 2% 2% 5% 5% 2% 2% 5% 4: 1 2 FUTURE SOLAR PANEL 4:12 4:12 G WMWM PUBLIC UTILITY EASEMENT 5' - 0 " 620 W ORION AVE., SANTA ANA, CA 5-GALLON SHRUB 24-INCH CANOPY TREE 1-GALLON SHRUB 1-GALLON SHRUB SCALE: 1/8" = 1'-0"1 EXISTING CONTOUR MAP SCALE: 1/8" = 1'-0"2 PROPOSED CONTOUR MAP SHEET NO.: SHEET TITLE: DATE: DR A W I N G S P R O V I D E D B Y : EM S O C A L E N G I N E E R I N G 24 8 8 1 A L I C I A P K W Y . , ST E . E - 2 2 2 , L A G U N A H I L L S 76 0 - 4 8 4 - 6 3 4 3 A7 EXISTING & PROPOSED CONTOUR MAP 10/10/24 61 8 & 6 2 0 W O R I O N AV E . , S A N T A A N A , CA 9 2 7 0 7 NE W D E T A C H E D AC C E S S O R Y DW E L L I N G U N I T RE V I S I O N T A B L E No . DA T E RE V I S E D B Y DE S C R I P T I O N GFI WP WP 220V EGD 3 4 D 220 vs FS CT R CLG SD T H J W TV ELECTRICAL SYMBOLS DUPLEX RECEPTACLE MOUNTED IN CEILING FOR GARAGE DOOR OPENER FLOOR MTD. RECEPTACLE POL BRASS RECEPTACLE 1/2 SWITCHED SINGLE POLE SWITCH 3 WAY SWITCH 4 WAY SWITCH DUPLEX RECEPTACLE ON ALL BRANCH CIRCUITS THAT SUPPLY 125- VOLT, SINGLE-PHASE, 15 & 20AMP RECEPTACLE OUTLETS IN DWELLING UNIT SHALL BE PROTECTED BY A COMBINATION TYPE (AFCI) ARC- FAULT CIRCUIT INTERRUPTER(S) PER 2010 CEC 210.12. FUSED SWITCH WATERPROOF RECEPTACLE DUPLEX RECEPTACLE ON GROUND-FAULT INTERRUPTED CIRCUIT DUPLEX RECEPTACLE LOCATED UNDER COUNTER 220V RECEPTACLE (VERIFY AMPERAGE REQUIREMENTS) RECESSED HIGH EFFICACY LIGHT FIXTURE WEATHER PROOF VAPOR PROOF, RECESSED, HIGH EFFICACY LIGH FIXTURE HANGING HIGH EFFICACY LIGHT FIXTURE - CHANDELIER I00 LB SUPPORT MIN. WALL MOUNTED HIGH EFFICACY LIGHT FIXTURE SURFACE MOUNTED HIGH EFFICACY LIGHT FIXTURE SOLAR POWERED, PHOTOCONTROL STEP MOUNTED LIGHT FIXTURE VENT / LIGHT COMBO, BY VENT AXIA CEILING EXHAUST FAN / FLUORESCENT LIGHT WHISPER FIT 4" DUCT. PANASONIC OR EQUAL STANDARD SERVICE TELEPHONE OUTLET CAT 5 COMBINED: COMPUTER DATA LINE AND TELEVISION CABLE OUTLET SMOKE DETECTOR SHALL BE PROTECTED BY AND ARC-FAULT CIRCUIT INTERRUPTER PER 2019 CEC 210.10. SMOKE DETECTORS SHALL HAVE A 10 YEAR BATTERY AND SHALL BE REPLACED 10 YEARS FROM THE DATE MARKED ON THE UNIT PER 2019 CBC 907.2.11.2, AND 2019 CRC R314 - R315. GAS LINE HOSE BIB JUNCTION BOX HEATING OUTLET IAQ FAN HUMIDISTAT CONTROL VACANCY LIGHT SWITCH 220 VOLT FUSED SWITCH SINGLE POLE SWITCH WITH DIMMER THERMOSTAT CARBON MONOXIDE ELECTRIC VEHICLE CHARGER VACANCY SENSOR UNDER-CABINET LED STRIP LIGHT DUPLEX RECEPTACLE LOCATED ABOVE CEILING CEILING EXHAUST FAN PANASONIC WHISPER FIT FAN 4" DUCT WITH HUMIDITY CONTROL HB GAS VS CM EVC C5 S VP DUPLEX RECEPTACLE FOR TELEVISION ELECTRIC PANEL INDOOR AIR HANDLER, MINI-SPLITAC F H ELECTRICAL ABBREVIATIONS A AMP AT AUTOMATIC TIME SWITCH CONTROL AST ASTRONOMICAL TIME CLOCK C/CW COLD WATER D DIMMER / DIMMABLE DED DEDICATED OUTLET / CIRCUIT EMCS EMERGENCY MANAGEMENT CONTROL SYSTEM (CENC 105 (K) 3,A,III,C) EV ELECTRICAL VEHICLE EVSE ELECTRIC VEHICLE SUPPLY EQUIPMENT FAU FORCED AIR UNIT FG NATURAL GAS FL FLOURESCENT FSR FIRE SPRINKLER RISER GFI GROUND FAULT CIRCUIT INTERRUPTER HB HOSE BIB HC HUMIDISTAT CONTROL HE HIGH EFFICACY H/HW HOT WATER JA8 COMPLAINT W/ APPENDIZ JA8 L, LED LED LIGHT FIXTURE LVL EVSE LEVEL MR MOISTURE RESISTANT (INDOOR) MS MOTION SENSOR PB PUSH BUTTON PC PHOTOCELL SOV SHUT OFF VALVE VS VACANCY SENSOR V VOLT WP WEATHER PROOF (RATED FOR EXTERIOR) ELECTRICAL NOTES CODE REFERENCES BASED ON 2022 CALIFORNIA ELECTRICAL CODE 1 MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS ARE SHOWN FOR INTENT ONLY. THESE SYSTEMS SHALL BE ENGINEERED BY OTHERS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER INSTALLATION AND PLACEMENT. 2 3 4 5 NUMBER OF CEILING JUNCTION BOXES NOT CONTAINING INSTALLED LIGHTING OR OTHER DEVICES SHALL NOT EXCEED NUMBER OF BEDROOMS. ELECTRICAL BOXES MUST BE SERVED BY A DIMMER, VACANCY SENSOR OR FAN SPEED CONTROL. CENC 150 (k) 1B 6 ELECTRONIC BALLASTS ARE REQUIRED FOR ALL LAMPS RATED 13 WATTS OR GREATER. 7 ALL INSTALLED LUMINAIRES SHALL BE HIGH-EFFICACY IN ACCORDANCE WITH CENC TABLE 150.0-A. (CENC 150 (k) 1A). 8 RECESSED LUMINAIRIES IN CEILINGS SHALL BE APPROVED FOR ZERO-CLEARANCE CONTACT (IC) & CERTIFIED AIRTIGHT, SHALL NOT CONTAIN SCREW BASED SOCKETS, AND SHALL BE SEALED WITH GASKET OR CAULK BETWEEN HOUSING AND CEILING, AND SHALL BE JA8 COMPLIANT, PER CENC 150.0 (k) 1C 9 DIMMERS OR VACANCY SENSORS SHALL CONTROL ALL LUMINAIRES REQUIRED TO HAVE JA8 COMPLIANT LIGHT SOURCES - CENC 150 (k) 2K). a. LIGHTING IN CLOSETS LESS THAN 70 SQ.FT. ARE NOT REQUIRED TO BE JA8 COMPLIANT - CENC 150(k) 2, k, EX. 1 b.RECESSED LIGHT FIXTURES IN HALLWAYS ARE NOT REQUIRED TO BE JA8 COMPLIANT - CENC 150 (k) 2K, EX. 2 10 AT LEAST ONE LUMINAIRE IN BATHROOMS, GARAGES, LAUNDRY ROOMS AND UTILITY ROOMS SHALL BE HIGH EFFICACY AND CONTROLLED BY VACANCY SENSORS (CENC 150 (k) 2J). 11 UNDERCABINET LIGHTING SHALL BE SWITCHED SEPARATELY FROM OTHER LIGHTING SYSTEMS. (CENC 150 (k) 2L). 12 EXHAUST FANS SHALL BE SWITCHED SEPARATELY FROM LIGHTING SYSTEM. (OR SEE EXCEPTION - CENC 150 (k) 2B.) 13 14 ALL KITCHEN, BATHROOM, LAUNDRY ROOM, GARAGE AND EXTERIOR RECEPTACLES SHALL BE GFCI PER CEC 210.8(A) 15 ALL 125-VOLT, 15 AND 20 AMPERE DWELLING UNIT RECEPTACLES SHALL BE LISTED TAMPER- RESISTANT PER CEC 406.12 16 PROVIDE A MINIMUM OF 2-20 AMP CIRCUITS TO KITCHEN COUNTERTOPS FOR SMALL APPLIANCES PER CEC 210.11 (C) (1) 17 PROVIDE A MINIMUM OF 1-20 AMP LAUNDRY BRANCH CIRCUIT PER CEC 210.11 (C) (2) 18 A DEDICATED 120V, 20 AMP CIRCUIT SHALL SERVE THE REQUIRED BATHROOM OUTLETS. THIS CIRCUIT CANNOT SUPPLY ANY OTHER RECEPTACLES, LIGHTS, FANS, ETC. CEC 210.11 (C) (3) 19 ALL BRANCH CIRCUITS SUPPLYING 12O-VOLT SINGLE-PHASE 15 & 20-AMPERE RECEPTACLE OUTLETS INSTALLED IN KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, REC ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS, OR SIMILAR SHALL BE PROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER(S) PER CEC 210.12(A). 20 STRUCTURED WIRING PANELS LOCATED IN CLOTHES CLOSET SHALL NOT CONTAIN OVERCURRENT DEVICES PER CEC 240.24 21 A 120V ELECTRIC RECEPTACLE SHALL BE LOCATED WITHIN 3FT FROM THE WATER HEATER AND BE ACCESSIBLE TO THE WATER HEATER WITHOUT OBSTRUCTIONS. (CENC 150 (n)1A) 22 23 RECEPTACLES THAT ARE REQUIRED AT THE FRONT AND REAR OF THE HOME, AND ON BALCONIES, DECKS & PORCHES, MUST BE WITHIN 6 FEET 6 INCHES OF GRADE (AND WATERPROOF AND GFCI PROTECTED). CEC 210.52 (E) & 210.8(A) EXTERIOR LIGHT FIXTURES & WEATHERPROOF OUTLETS SHALL BE INSTALLED PER CEC 410.10(A) & 406.9, & CENC 150.0 (k) 3 EXTERIOR LIGHTING SHALL BE CONTROLLED BY MANUAL ON & OFF SWITCH THAT DOES NOT OVERRIDE TO ON THE AUTOMATIC ACTIONS OF ITEMS ii OR iii BELOW. SHALL ALSO BE CONTROLLED BY ONE OF THE FOLLOWING: II. PHOTOCELL AND MOTION SENSOR OR III. ONE OF THE FOLLOWING: a. PHOTOCONTROL & AUTOMATIC TIMER b. ASTRONOMICAL TIME CLOCK c.RGY MANAGEMENT CONTROL SYSTEM (EMCS) AS NOTED CENC 150.0 (k) 3A INTERNALLY ILLUMINATED ADDRESS SIGNS SHALL:: a. COMPLY WITH CENC 140.8; or b. SHALL CONSUME NO MORE THAN 5 WATTS OF POWER AS DETERMINED ACCORDING TO CENC 130.0 ( c) 24 SMOKE ALARMS SHALL BE INTERCONNECTED W/ BATTERY BACKUP OR EMERGENCY ELECTRICAL SYSTEM CRC R314.4 25 SMOKE ALARMS SHALL BE PROVIDED IN THE FOLLOWING LOCATIONS: CRC R314.3 & R314.3.3 a. IN EACH SLEEPING ROOM b.OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS c.ON EACH ADDITIONAL STORY LOCATION REQUIREMENTS: d.MIN. 3 FT. FROM BATHROOMS WITH TUBS OR SHOWERS. e. MIN. 20 FT. FROM PERMANENTLY INSTALLED COOKING e) APPLIANCES. OR SEE EXCEPTIONS NFPA 29.8.3.4 WHEN UNABLE TO ACHIEVE DISTANCE REQUIRED. f.MIN. 3 FT. FROM TIP OF SUSPENDED CEILING FAN BLADE. g.WITHIN 12 IN. VERTICALLY FROM HIGHEST POINT OF SLOPED OR COFFERED CEILINGS. h.3 FT. HORIZONTAL PATH FROM THE SUPPLY REGISTERS OF A FORCED AIR HEATING OR COOLING SYSTEM AND SHALL BE INSTALLED OUTSIDE OF THE DIRECT AIRFLOW FROM THOSE REGISTERS. 26 CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: CRC R315.3 a.OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS b.ON EVERY OCCUPIABLE LEVEL, INCLUDING BASEMENTS c IN BEDROOMS CONTAINING A FUEL-BURNING APPLIANCE (I.E. FIREPLACE) ** COMBINATION SMOKE AND CARBON MONOXIDE ALARMS SHALL BE PERMITTED IN LIEU OF SMOKE ALARMS OR CO2 ALARMS CRC R314.5, R314.7.4, & R315.4 31 COMBINATION SMOKE AND CARBON MONOXIDE DETECTORS SHALL BE INTERCONNECTED AND RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING, OR FROM A BATTERY BACKUP WHEN PRIMARY POWER IS INTERRUPTED (CRC R314 AND R315) 32 TWO OR MORE SMALL APPLIANCE BRANCH CIRCUITS ARE REQUIRED FOR THE KITCHEN AND ARE LIMITED TO SUPPLYING WALL AND COUNTER SPACE OUTLETS FOR THE KITCHEN, PANTRY, BREAKFAST ROOM, DINING ROOM, OR SIMILAR AREAS. THESE CIRCUITS CANNOT SERVE OUTSIDE PLUGS, RANGE HOOD, DISPOSALS, DISHWASHERS OR MICROWAVES - ONLY THE REQUIRED COUNTERTOP/WALL OUTLETS INCLUDING THE REFRIGERATOR (CEC 210-11(C) & 210-52(B)) FAN/LIGHTS LOCATED WITHIN 3FT HORIZONTALLY AND 8FT VERTICALLY OF THE BATHTUB RIM OR SHOWER STALL THRESHOLD SHALL BE LISTED FOR A DAMP OR WET LOCATION ARE SUBJECT TO SHOWER SPRAY. (PER CEC 410.10 (D) ) COMBINATION SMOKE AND CARBON MONOXIDE ALARMS SHALL BE PERMITTED IN LIEU OF SMOKE ALARMS OR CO2 ALARMS (CRC R314.5, R314.7.4, & R315.4) 27 ATLEAST ONE 120-VOLT, 20-AMPERE BRANCH CIRCUIT SHALL BE INSTALLED TO SUPPLY RECEPTACLE OUTLETS IN ATTACHED GARAGES AND IN DETACHED GARAGES WITH ELECTRIC POWER. THIS CIRCUIT SHALL HAVE NO OTHER OUTLETS. EXCEPTION: CIRCUIT SHALL BE PERMITTED TO SUPPLY READILY ACCESSIBLE OUTDOOR RECEPTACLE OUTLETS (CEC 210.11) MECHANICAL NOTES CODE REFERENCES BASED ON 2022 CALIFORNIA MECHANICAL CODE 1. 2. 3. 4. 5. 6. 7. 8. a. b. 9. 10. 11. 12. 13. 14. 15. 16. 17. ROOMS CONTAINING TUBS, SHOWERS OR SIMILAR BATHING FIXTURES SHALL BE MECHANICALLY VENTILATED IN ACCORDANCE WITH CMC APPDX E 605.2 & CRC R303.3.1 INCLUDING ACCESSIBLE HUMIDISTAT CONTROL (CGBC 4.506.1) ALL EXHAUST DUCTS SHALL HAVE SMOOTH INTERIOR SURFACE AND TERMINATE OUTSIDE THE BUILDING AND SHALL BE EQUIPPED WITH A BACKDRAFT DAMPER. (CMC 504.1) TERMINATION OF ALL ENVIRONMENTAL AIR DUCTS (i.e., CLOTHES DRYER VENTS, BATH AND UTILITY FANS, ETC.) SHALL BE A MINIMUM OF 3 FEET FROM PROPERTY LINES OR ANY OPENINGS INTO THE BUILDING. PER CMC 502.2.1 DRYER VENT OUTLET SHALL BE MIN. 5 FT. FROM AIR CONDITIONING CONDENSER (CENC 150 (h) 3.A) PROVIDE MIN. 4" DIA. SMOOTH METAL DRYER VENT W/ BACKDRAFT DAMPER TO EXTERIOR. VENT RUN SHALL COMPLY WITH MNFR.'S SPECS. AND CMC 504.4.2 & 908. LENGTH OF RUN MAY EXCEED 14'-0" IF PERMITTED BY DRYER MNFR.'S INSTALLATION INSTRUCTIONS AND APPROVED BY THE AUTHORITY HAVING JURISDICTION. WHERE A CLOSET IS DESIGNED FOR THE INSTALLATION OF A CLOTHES DRYER, AN OPENING OF NOT LESS THAN 100 SQUARE INCHES FOR MAKEUP AIR SHALL BE PROVIDED IN THE DOOR OR BY OTHER APPROVED MEANS PER CMC 504.4.1 WHOLE BUILDING VENTILATION SHALL BE PROVIDED AND CONFIRMED THRU FIELD VERIFICATION & DIAGNOSTIC TESTING, PER CENC 150 (o) CALCULATION: 1 CFM PER 100 SF. FLOOR AREA PLUS NUMBER OF BEDROOMS PLUS ONE, MULTIPLIED BY 7.5 CFM. EXAMPLE: 1500 SF HOME W/ 3 BEDRMS = 15 CFM BLDG + 30 CFM PER OCCUPANT = 45 CFM REQUIRED. HOUSEHOLD COOKING APPLIANCES SHALL HAVE A VERTICAL CLEARANCE ABOVE THE COOKING TOP OF NOT LESS THAN 30INCHES TO COMBUSTIBLE MATERIAL OR METAL CABINETS (CMC 920.3.2) CLOTHES DRYER EXHAUST DUCT SHALL NOT BE CONNECTED TO A VENT CONNECTOR, GAS VENT OR CHIMNEY AND SHALL NOT TERMINATE INTO A CRAWL SPACE, ATTIC OR OTHER CONCEALED SPACE. EXHAUST DUCTS SHALL NOT BE ASSEMBLED WITH SCREWS OR OTHER FASTENING MEANS THAT EXTEND INTO THE DUCT AND THAT ARE CAPABLE OF CATHING LINT, AND THAT REDUCE THE EFFICIENCY OF THE EXHAUST SYSTEM. SCREENS SHALL NOT BE INSTALLED AT THE DUCT TERMINATION. WHERE JOINING OF DUCTS, THE MALE END SHALL BE INSERTED IN THE DIRECTION OF AIRFLOW (CMC 504.4) DOMESTIC CLOTHES DRYER MOISTURE EXHAUST DUCTS SHALL NOT EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGTH OF 14FT, INCLUDING TWO 90-DEGREE ELBOWS. A LENGTH OF 2FT SHALL BE DEDUCTED FOR EACH 90-DEGREE ELBOW IN EXCESS OF TWO (CMC 504.4.2.1) CLOTHES WASHER STANDPIPES SHALL BE 2INCH IN DIAMETER. NO TRAP FOR A CLOTHES WASHER STANDPIPE RECEPTOR SHALL BE INSTALLED BELOW THE FLOOR, BUT SHALL BE ROUGHED IN NOT LESS THAN 6INCHES AND NOT MORE THAN 18INCHES ABOVE THE FLOOR. (CPC 804.1) NO STANDPIPE RECEPTOR FOR A CLOTHES WASHER SHALL EXTEND MORE THAN 30INCHES AND NOT LESS THAN 18INCHES ABOVE ITS TRAP. (CPC 804.1) PROVIDE POSITIVE ELECTRICAL DISCONNECT (SEE SECT. NEC 503) LIGHT OVER CONTROLS (SECT. 309 ASO REQUIRES CONVENIENCE OUTLET (RECEPTACLE) WITHIN 25' OF EQUIP..) 24" WIDE SOLID FLOORING ACCESS WAY RELATED CODES SECTIONS: UMC 307.3 CENTRAL WARM AIR FURNACES INSTALLED IN THE ATTIC MUST BE ACCESSIBLE FOR ROUTINE INSPECTION AND MAINTENANCE BY THE OWNER, OCCUPANT AND FOR SERVICE AND REPAIR AS NEEDED. CHANGING FILTERS, LUBRICATING MOTOR AND FAN BEARINGS, CHECKING BELT TENSIONS AND RELIGHTING THE PILOT FOLLOWING A SERFICE INTERRUPTION ARE NORMAL OWNER FUNCTIONS. ADEQUATE LIGHT, AND ELECTRICAL OUTLET, SAFE ACCESS WAY AND SUFFICIENT WORKING SPACE ON THE CONTROL SIDE ALL ENCOURAGE AND FACILITATE MAINTENANCE AND ENABLE RAPID EGRESS IN AN EMERGENCY. ACCESS OPENING MIN. 22"X30" OR DIMENSION OF APPLIANCE LIGHT SWITCH 20'-0" MAX. WARM AIR FURNACE WORKING SPACE AT CONTROLS MAX 20'-0" -- MI N . C L R . 30 " - MIN . 0' - 6 " 2' - 6" SD EXT. LIGHTS MUST BE MOTION CENSOR AND PHOTOCELL. TYP.HB M 60 AMP PANEL FOR FUTURE ESS USE 100A SERVICE PANEL WITH 225 AMP MIN. BUSBAR RATING IAQ FAN, 50 CFM MIN. AC RETURN AIR VENT GA S CLOTHES DRYER MOISTURE EXHAUST DUCT (MIN. 4INCH DIA.) HB HB M HBM HB M SDCM ATTIC ACCESS 22"X30" 2 A4 HOOD OVER RANGE SHALL BE 180 CFM ELECTRICAL OUTLET FOR FUTURE USE GA S N SCALE: 3/16" = 1'-0"2 FURNACE AT ATTIC SCALE: 1/4" = 1'-0"1 PROPOSED ELECTRICAL PLAN SHEET NO.: SHEET TITLE: AS SHOWN SCALE: DATE: DR A W I N G S P R O V I D E D B Y : EM S O C A L E N G I N E E R I N G 24 8 8 1 A L I C I A P K W Y . , ST E . E - 2 2 2 , L A G U N A H I L L S 76 0 - 4 8 4 - 6 3 4 3 A4 PROPOSED ELECTRICAL PLAN 10/25/24 61 8 & 6 2 0 W O R I O N AV E . , S A N T A A N A , CA 9 2 7 0 7 NE W D E T A C H E D AC C E S S O R Y DW E L L I N G U N I T RE V I S I O N T A B L E NU M B E R DA T E RE V I S E D B Y DE S C R I P T I O N STRUCTURAL CALCULATIONS FOR: 618 Orion Ave, Santa Ana, CA 92707 SCOPE OF WORK: Detached ADU Engineer: Ehab Elias 24881 Alicia Pkwy, Ste E-222 Laguna Hills CA, 92653 TABLE OF CONTENTS I. DESIGN CRITERIA 3 II. LOADS 4 III. SEISMIC DESIGN 4 IV. GRAVITY DESIGN 7 V. FOUNDATION 5 VI. LATERAL ANALYSIS 6 CODE: 2022 CALIFORNIA BUILDING CODE WITH LOCAL ADDENDA Timber Douglas Fir Larch Rafters & Joints: #2 Grade Beams & Headers: As noted on plans Concrete F c’ = 2,500 PSI @ 28 days Reinforcing Steel ASTM A-615 #4 & Smaller, Grade #5 & Larger, Grade Soil Value 1,500 PSF per Soils IBC Typical Weights: Item PSF R-38 INS 1.5 ½ Gyp Board 2.2 Roofing (Shingles) 3.0 2x4 @ 16” O.C 1.1 2x6 @ 16” O.C 1.7 2x6 @ 24” O.C 2.3 2x8 @ 24” O.C 1.5 ½ Plywood 1.5 Stucco (7/8) 10.0 R-13 0.5 R-19 0.8 2x10 @ 16” O.C. 3.0 2x10 @ 24” O.C. 2.0 2x12 @ 16” O.C. 3.3 2x12 @ 24” O.C. 2.4 14” TJI Joist 4.2 TPO Roofing 0.5 ¾ Plywood 3.0 Rigid Fiberglass (1” thick) 1.5 5/8 Gyp Board 2.8 5/8 Gyp Type X 3.0 2x4 Interior Walls 10.0 3/8” Plywood 1.1 5/8” Plywood 1.8 ¾” Plywood 2.2 Glasss Wool 0.2 Ceramic Tile, ¾” 10.0 Wood Paneling 2.5 Clay Roof Tile 6.5 Hardie Board 2.3 LOADS Wall Loads (Exterior) 2x4 @ 16 1.1 ½ CDX Plywood 1.5 ½ Gyp Board 2.5 R-13 0.5 Siding 10.0 TOTAL 15.6+MISC = 17 DEAD LOAD Roof Loads Asphalt Shingles 3 Framing 2x6 @ 16 O.C. 1.7 Roofing Paper 0.3 ½ Plywood 1.5 Solar Panels 5 TOTAL 11.5 = 15 PSF Dead Load 20 PSF Live Load Ceiling Loads R-38 1.5 Framing 2x6 @ 16 O.C. 1.7 DryWall 2.2 TOTAL 5.4 = 10 PSF Dead Load 15 PSF Live Load SEISMIC DESIGN                            !"  #$%&'()*+&,-./&01+21&,+1/&3,&45676/&80, 912)2:;./&9*+<)2:;.=&>>?#4%#$5>777777$/&@$$6?%6#>A B12. CDEFEGDGHIJKFJCKLM B.N)<+&3*;.&O.P.(.+Q.&B*Q:R.+2 LSTFUCI O)NV&312.<*(W XX 0)2.&3Y1NN ZUZ[  CC H \] ^W_. `1Y:. B.NQ()_2)*+ C GFa MSTb     [ D G   ] C D HKa MSTb     [ C D ] MC K\K  U        MC U  CC H c  U        ZC DG\ d      D G  L ZC U  CC H c d      C D  L ^W_. `1Y:. B.NQ()_2)*+ ZS U  CC H c       e fC G       D G  f U  CC H c       C D  gL D KHK MST!     fgL C G       gL gLM D IKH     !     DRAG LINE LEGENDS: NTS. sheet no.:A2 Ehab Elias, P.E. Project:618 Orion Ave ROOF: roof DL= 10 psf partitions=5 psf W roof=15 psf 2ND FLOOR:floor DL=0 psf partitions=0 psf w floor=0 psf W Total=15 psf Latitude;33.698612 longitude:-117.8763 Ss 1.279 S1 0.459 Site Class:D Risk Category:II ASCE 7 Table 1.5-1 Ie=1 ASCE 7 Table 1.5-2 Fa=1.2 SMS 1.535 SDS 1.023 D ASCE 7 Table 11.6-1 rho=1.3 Plywood Shear Walls 6.5 ASCE 7 Table 12.2-1 Base Shear Coefficient SDS*I/R=Cs=0.157 (Strength) 0.7SDS*I/R Cs=0.110 (Service) V=CsW=V=2.92 psf Seismic Calcs 15 lb/sf Lb 800 sf 9,180 lb 120 ft 4.5 ft 17 lb/sf 21,180 lb 2.92 lb/sf Wind Load Calcs 9.6 lb/sf L=40 6,912 lb W=20 3,456 lb LATERAL ANALYSIS (ASCE 7-16) STORY WEIGHTS: SEISMIC: Maximum Short Period Response: maximum 1 sec. Period Response: Importance Factor: Site Coefficient: EQUIVALENT LATERAL FORCE PROCEDURE (ASCE 7 Section 12.8): Site Spectural Accel Value Design Response: Seismic Design Category: Redundancy Factor Seismic Force Resisting System Response Modification Factor Wroof = Bld. Area x Roof SF weight= Bld. Area= 12,000 Wwall = Bld. Circumference x (ceiling heigh/2)x wall wight per LF Bld. Circumference = Wind Load= Wind Pressure x Wall Height x L x 2= Wind Load= Wind Pressure x Wall Height x W x 2= Celing Heigh / 2 = Wall Wight = Wtotal= Wroof + Wwall = V = Cs x Wtotal/Bld Area = Wind Pressure (16 lb/sf) x 0.6 sheet no.:A3 Ehab Elias, P.E. Project:618 Orion Ave 2.92 psf Mbal= ((0.6-0.14SDS)xDL) X L^2/2 Seismic Wall NO. Lw Total (ft) HW (FT) Trib. Area (sf) V (pounds) Add'l Shear V/L (plf) **Wall Type Smallest DL (plf) OTM (ft-lbs) Mbal (ft-lbs) Uplift (lbs) Simpson Holdown 1 8 9 267 779 97 2 4 100 3504 365 785 HDU4 1 8 9 267 779 97 2 4 100 3504 365 785 HDU4 2 12 9 267 779 65 2 4 100 2336 365 493 HDU4 WIND: Wall NO. Lw Total (ft) HW (FT) Trib. Area (sf)V/L (PLF) **Wall Type Smallest OTM (ft-lbs) RM (ft- lbs) Uplift (lbs) Simpson Holdown 1 8 9 267 288 2 4 10381 1368 2390 HDU4 1 8 9 267 288 2 4 10381 1368 2390 HDU5 2 12 9 267 192 2 8 13841 5472 1320 HDU4 OTM= OTM= (V/L (plf x Lw) x Hw RM= RM= (Wall DL(psf) x Lw x Hw) x (Lw/2) T&C= T&C= (OTM - (0.6*RM))/Lw Seismic Wall NO.Lw Total HW Trib. Area V Add'l V/L (plf)**Wall Smallest DL (plf)OTM Mbal Uplift Simpson A 12 9 400 1167 97 1 4 100 3500 365 784 HDU4 B 12 9 400 1167 97 1 4 100 3500 365 784 HDU4 WIND: Wall NO.Lw Total HW Trib. Area V/L (PLF)**Wall Smallest OTM RM (ft-Uplift Simpson A 12 9 400 144 1 4 5184 1368 1091 HDU4 B 12 9 400 144 1 4 5184 1368 1091 HDU4 Wall type Nailing Capaciy (plf) Simpson Hold Down Capacity (lbs) 1 8d at 6" o.c. 260 HDU2 2306 2 8d at 4" o.c. 380 Wall A,B,1&2 HDU4 3424 Wall A,B,1&2 3 8d at 3" o.c. 490 HDU5 4234 *Capacities have been reduce by 25% DESIGN LATERAL FORCES ON SHEAR WALLS Roof Diaphragm Shear= Cs X 1.0= GRAVITY DESIGN            !"#$%&'(!)*+, -./0!1!-2 /./.!)03452, 6#++7!)-89, :: .35!;!<!.35!=!)>**!?@#(+, ?A# !)*+, ./B8!1!.C!.2 4B-- 6#++7!)0-9, .355 .35!;!<!.35!=!)>**!?@#(+, '(%!)D%:*+, /E/B!1!/C!0!.F-2 B058 6#++7!)B09, .355 .35!;!<!.35!=!)>**!?@#(+, =&G!='#7!;H*3!)&(, 5308I!1!/C!0!.F-2 534I- 6#++7!)=F4-., :: .35!;!<!.35!=!)>**!?@#(+, J'%#*!='#7!;H*3!)&(, 53E48!1!/C!0!.F-2 53/.0 6#++7!)=F-B8, :: .35!;!<!.35!=!)>**!?@#(+,  !=(K%A!L!.EC!82 ?M+%!L!D*''  !JM@!L!; '@!N# NO&*7&(K!P+!L!"+&7(%&#* NO&*7&(K!Q'7!L!RNQ!-5./ ;+&K(!%A'7'*'KM!L!>?; S;H*$%&'(!$ &% &#L!==!)=F0E5,!#(7!J=!)=F-I5,3 S>**'T7!'(%!7'+!('%! H*$%!%A!#7UO+%(%!H' !%A!#!+%#&*&%M!H#$%' 3 S=O !K #7&(K!@ 'G&+&'(+!O+%!!V%(77!'G !%A!*(K%A!'H!%A! !@ !W;?!I3-34343 S>@@*&$#*!$#*$O*#%&'(+!# !#+7!'(!W;?3 S!N*'$X&(K!6#(*+!# !#++O7!%'!$# M!('!*'#7+!#@@*&7!7& $%*M!#'G!%A!#(7!%A!HO**!*'#7!&+!#@@*&7!%'!%A! !&(K!7+&K(73 Y  Z   [\\   [\\ ] ^   _  ^   .!:!?%O7!T#**!:!?6D 03452 03452 .3452 B0B .-II -./0 N*'$X&(K -!:!?%O7!T#**!:!?6D 03452 03452 .3452 B0B .-II -./0 N*'$X&(K S#V&O!#**'T#*! #$&(K!&(% G#*+!#+7!'(!#@@*&7!*'#73   Y Y ` ^   J'@!a7K!)=O, .EC!82!'F$ N'%%'!a7K!)=O, .EC!82!'F$ S!?&7!*'#7+!# !#++O7!%'!('%!&(7O$!$ '++:K #&(!%(+&'(3   ^ b    [] c d Z efgehfee  5!:!?*H!i&KA%!)6=D, 5!%'!.EC!82 WF> .03- :: .!:!P(&H' !)6?D, 5!%'!.EC!82!)D '(%, .5C .535 .435 ;H#O*%!='#7 iM A#O+ !T# #(%+!%A#%!%A!+&j&(K!'H!&%+!@ '7O$%+!T&**!!&(!#$$' 7#($!T&%A!iM A#O+ !@ '7O$%!7+&K(!$ &% &#!#(7!@O*&+A7!7+&K(!G#*O+3!iM A#O+ !V@ ++*M!7&+$*#&+!#(M!'%A !T# #(%&+ *#%7!%'!%A!+'H%T# 3!P+!'H!%A&+!+'H%T# !&+!('%!&(%(77!%'!$& $OG(%!%A!(7!H' !#!7+&K(!@ 'H++&'(#*!#+!7% &(7!M!%A!#O%A' &%M!A#G&(K!UO &+7&$%&'(3!JA!7+&K( !'H! $' 7k!O&*7 !' !H # !&+ +@'(+&*!%'!#++O !%A#%!%A&+!$#*$O*#%&'(!&+!$'@#%&*!T&%A!%A!'G #**!@ 'U$%3!>$$++' &+!)"&!N'# 7k!N*'$X&(K!6#(*+!#(7!?lO#+A!N*'$X+,!# !('%!7+&K(7!M!%A&+!+'H%T# 3!6 '7O$%+!#(OH#$%O 7!#% iM A#O+ !H#$&*&%&+!# !%A& 7:@# %M!$ %&H&7!%'!+O+%#&(#*!H' +% M!+%#(7# 7+3!iM A#O+ !a(K&( 7!=O !6 '7O$%+!!A#G!(!G#*O#%7!M!RQQ:a?!O(7 !G#*O#%&'(! @' %+!a?":..40!#(7!a?":.0/8 #(7F' !%+%7!&(!#$$' 7#($!T&%A!#@@*&$#*!>?J!+%#(7# 7+3!D' !$O (%!$'7!G#*O#%&'(! @' %+k!iM A#O+ !@ '7O$%!*&% #%O !#(7!&(+%#**#%&'(!7%#&*+! H !%'!TTT3TM A#O+ 3$'FT''7@ '7O$%+F 7'$O(%:*& # M3 JA!@ '7O$%!#@@*&$#%&'(k!&(@O%!7+&K(!*'#7+k!7&(+&'(+!#(7!+O@@' %!&(H' #%&'(!A#G!(!@ 'G&77!M!D' %iaN!?'H%T# !m@ #%' dcZ n  ; #T&(K!&+!Q'($@%O#*3!>**!*'$#%&'(+!# !#+O 7!H '!%A!'O%+&7!H#$!'H!*H%!+O@@' %!)' !*H%!$#(%&*G !(7,3!>**!7&(+&'(+!# !A' &j'(%#*!)%M@3,3 opoYppq] [[p =G*k!D*'' L!; '@!N# h\ rshenfh  dpY[t  q\ un .5F8F-5-I!-L.BL0-!6!PJQ aA#!a*&#+ ?% O$%O #*!v(%O + )8E5,!I/I:E0I0 *&#+A#1K#&*3$' D' %iaN!G03/k!a(K&(L!v/3I3.3-Ik!;#%#L!v/3.3E30 D&*!W#L!m &'(!N#+ wxyz{|{}{|            !"#$%&'(!)*+, -./!0!-!12-3 --/1!)/4.53, 6#++7!)118, 99 145!:!;!145!< !)=**!>?#(+, >@# !)*+, -1A!0!A!1121B3 1-/A 6#++7!)1A8, 14-. 145!:!;!145!< !)=**!>?#(+, '(%!)C%9*+, B1D!0!.E!/!12-3 11DA 6#++7!).-8, 14-. 145!:!;!145!< !)=**!>?#(+, <&F!<'#7!:G*4!)&(, 54-51!0!.E!/!12-3 54./B 6#++7!)<2B/A, 99 145!:!;!145!< !)=**!>?#(+, H'%#*!<'#7!:G*4!)&(, 54/B1!0!.E!/!12-3 54D1I 6#++7!)<2/.D, 99 145!:!;!145!< !)=**!>?#(+,  !<(J%@!K!11E!/!1121B3 >L+%!K!"''G  !HL?!K!M'&+% NO&*7&(J!P+!K!"+&7(%&#* NO&*7&(J!Q'7!K!RNQ!-51A :+&J(!%@'7'*'JL!K!=>:  !6&%$@!K!I21- S:G*$%&'(!$ &% &#K!<<!)<2-I5,!#(7!H<!)<21A5,4 S=**'T7!'(%!7'+!('%! G*$%!%@!#7UO+%(%!G' !%@!#!+%#&*&%L!G#$%' 4 S=!1.8!&($ #+!&(!%@!'(%!$#?#$&%L!@#+!(!#777!%'!#$$'O(%!G' ! ?%&%&F! !O+#J4 S=??*&$#*!$#*$O*#%&'(+!# !#+7!'(!V:>4 S!N*'$W&(J!6#(*+!# !#++O7!%'!$# L!('!*'#7+!#??*&7!7& $%*L!#'F!%@!#(7!%@!GO**!*'#7!&+!#??*&7!%'!%@! !&(J!7+&J(74 X  Y   Z[[   Z[[ \ ]   ^ _]   1!9!>%O7!T#**!9!>6C /4.53 /4.53 14.53 11- 1I1 -./ N*'$W&(J -!9!>%O7!T#**!9!>6C /4.53 /4.53 14.53 11- 1I1 -./ N*'$W&(J S#`&O!#**'T#*! #$&(J!&(% F#*+!#+7!'(!#??*&7!*'#74 S:&(+&'(+!G' !*#% #*! #$&(J!&(% F#*+!# !#+O 7!#*'(J!%@!*(J%@!'G!%@! !G' !+*'?7!$'(7&%&'(+4   X X a ]   H'?!b7J!)<O, 11E!-3!'2$ N'%%'!b7J!)<O, 11E!-3!'2$  _] c    ZZ[ defdgehi  1!9!P(&G' !)6>C, 5!%'!15E!D3 1B3 1.45 -545 :G#O*%!<'#7 jL @#O+ !T# #(%+!%@#%!%@!+&k&(J!'G!&%+!? '7O$%+!T&**!!&(!#$$' 7#($!T&%@!jL @#O+ !? '7O$%!7+&J(!$ &% &#!#(7!?O*&+@7!7+&J(!F#*O+4!jL @#O+ !`? ++*L!7&+$*#&+!#(L!'%@ !T# #(%&+ *#%7!%'!%@!+'G%T# 4!P+!'G!%@&+!+'G%T# !&+!('%!&(%(77!%'!$& $OF(%!%@!(7!G' !#!7+&J(!? 'G++&'(#*!#+!7% &(7!L!%@!#O%@' &%L!@#F&(J!UO &+7&$%&'(4!H@!7+&J( !'G! $' 7l!O&*7 !' !G # !&+ +?'(+&*!%'!#++O !%@#%!%@&+!$#*$O*#%&'(!&+!$'?#%&*!T&%@!%@!'F #**!? 'U$%4!=$$++' &+!)"&!N'# 7l!N*'$W&(J!6#(*+!#(7!>mO#+@!N*'$W+,!# !('%!7+&J(7!L!%@&+!+'G%T# 4!6 '7O$%+!#(OG#$%O 7!#% jL @#O+ !G#$&*&%&+!# !%@& 79?# %L!$ %&G&7!%'!+O+%#&(#*!G' +% L!+%#(7# 7+4!jL @#O+ !b(J&( 7!<O !6 '7O$%+!!@#F!(!F#*O#%7!L!RQQ9b>!O(7 !F#*O#%&'(! ?' %+!b>"911./!#(7!b>"91/AD #(72' !%+%7!&(!#$$' 7#($!T&%@!#??*&$#*!=>H!+%#(7# 7+4!C' !$O (%!$'7!F#*O#%&'(! ?' %+l!jL @#O+ !? '7O$%!*&% #%O !#(7!&(+%#**#%&'(!7%#&*+! G !%'!TTT4TL @#O+ 4$'2T''7? '7O$%+2 7'$O(%9*& # L4 H@!? '7O$%!#??*&$#%&'(l!&(?O%!7+&J(!*'#7+l!7&(+&'(+!#(7!+O??' %!&(G' #%&'(!@#F!(!? 'F&77!L!C' %jbN!>'G%T# !n? #%' opY q  : #T&(J!&+!Q'($?%O#*4!=**!*'$#%&'(+!# !#+O 7!G '!%@!'O%+&7!G#$!'G!*G%!+O??' %!)' !*G%!$#(%&*F !(7,4!=**!7&(+&'(+!# !@' &k'(%#*!)%L?4,4 rsrXsst\ ZZs <F*l!"''GK!M'&+% g[ huvqeggvwt  osXZ_  t[ xq 152D2-5-I!-K-1K5D!6!PHQ b@#!b*&#+ >% O$%O #*!y(%O + )DB5,!IAI9B/I/ *&#+@#0J#&*4$' C' %jbN!F/4Al!b(J&(K!yA4I414-Il!:#%#K!yA414B4/ C&*!V#K!n &'(!N#+ z{|}~~€~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`  ^   .!:!?%Q7!U#**!:!?6C 345/2 345/2 .45/2 BJ .-D -./ P*'$X&(K -!:!?%Q7!U#**!:!?6C 345/2 345/2 .45/2 BJ .-D -./ P*'$X&(K T#a&Q!#**'U#*! #$&(K!&(% G#*+!#+7!'(!#@@*&7!*'#74   Y Y b ^   I'@!c7K!)=Q, .-F!32!'1$ P'%%'!c7K!)=Q, .-F!E2!'1$ T!d(*M!G %&$#*!*'#7+!# !#G#&*#*!H' !>%%&$!O'&+%! !%M@+4!W'!%(+&'(!*'#7&(K!U&**!!$'(+&7 7!&(!%A!7+&K(!H' !%A+! +4    `  ^ e    [[\ fghfigff  .!:!R(&H' !)6?C, /!%'!.-F!E2 .D2 ./4/ .54/ ;H#Q*%!='#7 jM A#Q+ !U# #(%+!%A#%!%A!+&k&(K!'H!&%+!@ '7Q$%+!U&**!!&(!#$$' 7#($!U&%A!jM A#Q+ !@ '7Q$%!7+&K(!$ &% &#!#(7!@Q*&+A7!7+&K(!G#*Q+4!jM A#Q+ !a@ ++*M!7&+$*#&+!#(M!'%A !U# #(%&+ *#%7!%'!%A!+'H%U# 4!R+!'H!%A&+!+'H%U# !&+!('%!&(%(77!%'!$& $QG(%!%A!(7!H' !#!7+&K(!@ 'H++&'(#*!#+!7% &(7!M!%A!#Q%A' &%M!A#G&(K!VQ &+7&$%&'(4!IA!7+&K( !'H! $' 7l!Q&*7 !' !H # !&+ +@'(+&*!%'!#++Q !%A#%!%A&+!$#*$Q*#%&'(!&+!$'@#%&*!U&%A!%A!'G #**!@ 'V$%4!>$$++' &+!)"&!P'# 7l!P*'$X&(K!6#(*+!#(7!?mQ#+A!P*'$X+,!# !('%!7+&K(7!M!%A&+!+'H%U# 4!6 '7Q$%+!#(QH#$%Q 7!#% jM A#Q+ !H#$&*&%&+!# !%A& 7:@# %M!$ %&H&7!%'!+Q+%#&(#*!H' +% M!+%#(7# 7+4!jM A#Q+ !c(K&( 7!=Q !6 '7Q$%+!!A#G!(!G#*Q#%7!M!SNN:c?!Q(7 !G#*Q#%&'(! @' %+!c?":..53!#(7!c?":.3BE #(71' !%+%7!&(!#$$' 7#($!U&%A!#@@*&$#*!>?I!+%#(7# 7+4!C' !$Q (%!$'7!G#*Q#%&'(! @' %+l!jM A#Q+ !@ '7Q$%!*&% #%Q !#(7!&(+%#**#%&'(!7%#&*+! H !%'!UUU4UM A#Q+ 4$'1U''7@ '7Q$%+1 7'$Q(%:*& # M4 IA!@ '7Q$%!#@@*&$#%&'(l!&(@Q%!7+&K(!*'#7+l!7&(+&'(+!#(7!+Q@@' %!&(H' #%&'(!A#G!(!@ 'G&77!M!C' %jcP!?'H%U# !d@ #%' noZ p  ; #U&(K!&+!N'($@%Q#*4!>**!*'$#%&'(+!# !#+Q 7!H '!%A!'Q%+&7!H#$!'H!*H%!+Q@@' %!)' !*H%!$#(%&*G !(7,4!>**!7&(+&'(+!# !A' &k'(%#*!)%M@4,4 qrqYrrs] [[r =G*l!N&*&(KL!>%%&$!O'&+% i\ tuvpgiivws  nrY[x  s\ yp ./1E1-/-J!3L/EL//!6!RIN cA#!c*&#+ ?% Q$%Q #*!z(%Q + )ED/,!JBJ:D3J3 *&#+A#0K#&*4$' C' %jcP!G34Bl!c(K&(L!zB4J4.4-Jl!;#%#L!zB4.4D43 C&*!W#L!d &'(!P#+ {|}~€ € CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:New ADU Calculation Date/Time:2024-10-03T16:15:34-07:00 (Page 1 of 11) Calculation Description:Compliance Input File Name:618 Oron Ave.ribd22 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-10-03   16:16:05 GENERAL INFORMATION 01 Project Name New ADU 02 Run Title Compliance 03 Project Location 618 Orion Ave 04 City Santa Ana 05 Standards Version 2022 06 Zip code 92707 07 Software Version CBECC-Res 2022.3.1 08 Climate Zone 8 09 Front Orientation (deg/ Cardinal)270 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Newly Constructed 13 Number of Bedrooms 2 14 Addition Cond. Floor Area (ft2)0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft2)n/a 17 Fenestration Average U-factor 0.3 18 Total Cond. Floor Area (ft2)800 19 Glazing Percentage (%)10.87% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Fuel Type Natural gas 23 No Dwelling Unit:No COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 424-P010236461A-000-000-0000000-0000 10/04/2024 07:53 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:New ADU Calculation Date/Time:2024-10-03T16:15:34-07:00 (Page 2 of 11) Calculation Description:Compliance Input File Name:618 Oron Ave.ribd22 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-10-03   16:16:05 ENERGY DESIGN RATINGS Energy Design Ratings Compliance Margins Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Standard Design 37.1 38.4 27.7 Proposed Design 35.7 36.6 26.9 1.4 1.8 0.8 RESULT3: PASS 1Efficiency EDR includes improvements like a better building envelope and more efficient equipment 2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries 3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded •Standard Design PV Capacity: 2.06 kWdc •PV System resized to 2.06 kWdc (a factor of 2.063) to achieve 'Standard Design PV' PV scaling 424-P010236461A-000-000-0000000-0000 10/04/2024 07:53 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:New ADU Calculation Date/Time:2024-10-03T16:15:34-07:00 (Page 3 of 11) Calculation Description:Compliance Input File Name:618 Oron Ave.ribd22 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-10-03   16:16:05 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0.13 0.65 0.13 0.93 0 -0.28 Space Cooling 1.3 29 1.56 34.47 -0.26 -5.47 IAQ Ventilation 0.49 5.1 0.21 2.19 0.28 2.91 Water Heating 2.23 23.49 1.67 17.99 0.56 5.5 Self Utilization/Flexibility Credit 0 0 0 0 Efficiency Compliance Total 4.15 58.24 3.57 55.58 0.58 2.66 Photovoltaics -2.83 -85.12 -2.83 -84.96 Battery 0 0 Flexibility 0 Indoor Lighting 0.94 8.78 0.94 8.78 Appl. & Cooking 6.51 42.13 6.52 42.21 Plug Loads 5.68 57.83 5.68 57.83 Outdoor Lighting 0.21 1.8 0.21 1.8 TOTAL COMPLIANCE 14.66 83.66 14.09 81.24 424-P010236461A-000-000-0000000-0000 10/04/2024 07:53 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:New ADU Calculation Date/Time:2024-10-03T16:15:34-07:00 (Page 4 of 11) Calculation Description:Compliance Input File Name:618 Oron Ave.ribd22 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-10-03   16:16:05 ENERGY USE INTENSITY Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Compliance Margin (kBtu/ft2 - yr )Margin Percentage Gross EUI1 22.57 21.87 0.7 3.1 Net EUI2 8.18 7.49 0.69 8.44 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. REQUIRED PV SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg) Tilt: (x in 12) Inverter Eff. (%) Annual Solar Access (%) 2.06 NA Standard (14-17%)Fixed none true 150-270 n/a n/a <=7:12 96 98 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •PV System: 2.06 kWdc •IAQ Ventilation System: as low as 0.15 W/CFM •Insulation below roof deck •Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed 424-P010236461A-000-000-0000000-0000 10/04/2024 07:53 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:New ADU Calculation Date/Time:2024-10-03T16:15:34-07:00 (Page 5 of 11) Calculation Description:Compliance Input File Name:618 Oron Ave.ribd22 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-10-03   16:16:05 HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Quality insulation installation (QII) •Indoor air quality ventilation •Kitchen range hood •Minimum Airflow •Verified Refrigerant Charge •Fan Efficacy Watts/CFM •Verified heat pump rated heating capacity BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems New ADU 800 1 2 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status ADU Zone Conditioned HVAC System 2 800 9 DHW System 1 New OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) Front Wall ADU Zone R-15 Exterior Wall 270 Front 180 40 90 Back Wall ADU Zone R-15 Exterior Wall 90 Back 180 34 90 Right Wall ADU Zone R-15 Exterior Wall 180 Right 360 33 90 Left Wall ADU Zone R-15 Exterior Wall 0 Left 360 20 90 Ceiling (below attic) 1 ADU Zone R-38 Ceiling Rafter n/a n/a 800 n/a n/a 424-P010236461A-000-000-0000000-0000 10/04/2024 07:53 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:New ADU Calculation Date/Time:2024-10-03T16:15:34-07:00 (Page 6 of 11) Calculation Description:Compliance Input File Name:618 Oron Ave.ribd22 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-10-03   16:16:05 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Asphalt Shingle Roof Ventilated 4 0.1 0.85 Yes No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading W4 Window Front Wall Front 270 4 5 1 20 0.3 NFRC 0.23 NFRC Bug Screen W1 Window Back Wall Back 90 5 5 1 25 0.3 NFRC 0.23 NFRC Bug Screen W2 Window Back Wall Back 90 3 3 1 9 0.3 NFRC 0.35 NFRC Bug Screen W3 Window Right Wall Right 180 6 4 1 24 0.3 NFRC 0.35 NFRC Bug Screen W2-2 Window Right Wall Right 180 3 3 1 9 0.3 NFRC 0.35 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2)U-factor D1 Front Wall 20 0.2 D4 Left Wall 20 0.2 SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab On Grade 1 ADU Zone 800 120 none 0 80%No 424-P010236461A-000-000-0000000-0000 10/04/2024 07:53 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:New ADU Calculation Date/Time:2024-10-03T16:15:34-07:00 (Page 7 of 11) Calculation Description:Compliance Input File Name:618 Oron Ave.ribd22 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-10-03   16:16:05 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-15 Exterior Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.081 Inside Finish: Gypsum Board Sheathing / Insulation: Wood Siding/sheathing/decking Cavity / Frame: R-15 / 2x4 Sheathing / Insulation: Wood Siding/sheathing/decking Exterior Finish: 3 Coat Stucco Asphalt Shingle Roof Attic Roofs Wood Framed Ceiling 2x6 @ 16 in. O. C.R-19 None / None 0.056 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-19 / 2x6 Inside Finish: Gypsum Board R-38 Ceiling Rafter Ceilings (below attic) Wood Framed Ceiling 2x10 @ 16 in. O. C.R-38 None / None 0.026 Over Ceiling Joists: R-13.9 insul. Cavity / Frame: R-24.1 / 2x10 Sheathing / Insulation: Wood Siding/sheathing/decking Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Required Not Required N/A n/a n/a 424-P010236461A-000-000-0000000-0000 10/04/2024 07:53 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:New ADU Calculation Date/Time:2024-10-03T16:15:34-07:00 (Page 8 of 11) Calculation Description:Compliance Input File Name:618 Oron Ave.ribd22 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-10-03   16:16:05 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#) DHW System 1 Domestic Hot Water (DHW)Standard Water Heater 1 1 n/a None n/a Water Heater 1 (1) WATER HEATERS - NEEA HEAT PUMP 01 02 03 04 05 06 07 08 Name # of Units Tank Vol. (gal)NEEA Heat Pump Brand NEEA Heat Pump Model Tank Location Duct Inlet Air Source Duct Outlet Air Source Water Heater 1 1 50 Generic NEEA Tier 4 Generic 50 TankZone Outside Outside WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW System 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type HVAC System 2 Heat pump heating cooling Heat Pump System 1 1 Heat Pump System 1 1 HVAC Fan System 1 Distribution System 1 Setback 424-P010236461A-000-000-0000000-0000 10/04/2024 07:53 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:New ADU Calculation Date/Time:2024-10-03T16:15:34-07:00 (Page 9 of 11) Calculation Description:Compliance Input File Name:618 Oron Ave.ribd22 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-10-03   16:16:05 HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS VerificationHeating Efficiency Type HSPF/HS PF2/COP Cap 47 Cap 17 Cooling Efficiency Type SEER/SE ER2 EER/EER 2/CEER Heat Pump System 1 Central split HP 1 HSPF2 7.5 18000 12600 EER2SEER2 14.3 11.7 Not Zonal Single Speed Heat Pump System 1-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEER/SEER2 Verified Refrigerant Charge Verified HSPF/HSPF2 Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 1-hers-htpump Required 350 Not Required Not Required Yes No Yes Yes HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Name Type Design Type Duct Ins. R-value Duct Location Surface Area Bypass Duct Duct Leakage HERS Verification Supply Return Supply Return Supply Return Distribution System 1 Unconditioned attic Non-Verified R-6 R-6 Attic Attic n/a n/a No Bypass Duct Existing (not specified) Distribution System 1-hers-dist HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan System 1 HVAC Fan 0.45 HVAC Fan System 1-hers-fan 424-P010236461A-000-000-0000000-0000 10/04/2024 07:53 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:New ADU Calculation Date/Time:2024-10-03T16:15:34-07:00 (Page 10 of 11) Calculation Description:Compliance Input File Name:618 Oron Ave.ribd22 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-10-03   16:16:05 HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan System 1-hers-fan Required 0.45 INDOOR AIR QUALITY (IAQ) FANS 01 02 03 04 05 06 07 08 09 Dwelling Unit Airflow (CFM)Fan Efficacy (W/CFM)IAQ Fan Type Includes Heat/Energy Recovery? IAQ Recovery Effectiveness - SRE/ASRE Includes Fault Indicator Display?HERS Verification Status SFam IAQVentRpt 1-1 50 0.15 Exhaust No n/a / n/a No Yes 424-P010236461A-000-000-0000000-0000 10/04/2024 07:53 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E Project Name:New ADU Calculation Date/Time:2024-10-03T16:15:34-07:00 (Page 11 of 11) Calculation Description:Compliance Input File Name:618 Oron Ave.ribd22 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2024-10-03   16:16:05 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Albert Luu DHL Consultant 10/03/2024 10732 La Batista Ave R22-22 40020 Fountain Valley, CA 92708 (714) 679-6472 Lyndon de Guzman OC-ADU 10/04/2024 24752 Via Balboa Laguna Hills, CA 92653 9494148799 424-P010236461A-000-000-0000000-0000 10/04/2024 07:53 CHEERS NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. Digitally signed by California Home Energy Efficiency Rating Services (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Planning & Building Agency Building and Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714)-647-5800 www.santa-ana.org DETACHED ADU GRADING PERMIT WAIVER REQUEST THIS WAIVER SHALL BE COMPLETED BY THE LEGAL PROPERTY OWNER(S) A grading permit is required for all new detached buildings including new detached Accessory Dwelling Unit (ADU) projects. Precise grading plans prepared and stamped by a registered professional engineer shall be required to be submitted before or concurrently with the architectural plans submittal to the Building Safety Division. Grading Permit Waiver: Residential detached Accessory Dwelling Unit (ADU) projects with a total building area of 1,200 sq. feet or less may be eligible for a grading permit waiver request if all of the following conditions are met. The property owner(s) shall take full responsibility for the site drainage by signing this waiver request agreement below. In order to qualify for the grading permit waiver, the property owner(s) shall complete all sections, check appropriate boxes, and sign this waiver request. A copy of this completed checklist shall be made part of the each set of plans. If answering NO to any of the questions, a grading plan and permit shall be required. Project Property Address: Yes No 1. ☐ ☐ 2. ☐ ☐ 3. ☐ ☐ The site drainage shall be constructed such that surface water flows away from buildings and adjoining property lines, in accordance with all applicable codes. 4. ☐ ☐ The site drainage shall be constructed such that the drainage will not adversely affect the adjoining properties. 5. ☐ ☐ The project plans includes a site plan that shows site drainage patterns. Grading Permit Waiver Request I/we are requesting a waiver from the standard requirements for a precise grading plan and permit for our ADU project to be constructed at the project address indicated above. In doing so, I/we accept that the design of the site drainage patterns must adhere to the minimum requirements set forth in the current building codes and the County of Orange Drainage Design Manual. By signing this waiver request: (1) I/we certify that I/we are the legal property owner(s); (2) I/we agree to take full liability for the site drainage; (3) I/we agree that the checked box conditions above are true; and (4) I/we agree to defend, indemnify, and hold harmless the City of Santa Ana, its officials, employees, and agents against any and all claims for damages and costs arising out of the site drainage at the project property. Owner Name(s): (Print) Owner Signature(s): Date: Phone Number: Notes: 1. The building official reserves the right to require a grading permit based on site conditions. 2. This grading permit waiver request does not apply to projects in the FEMA Flood Zones. 1/14/2025 714-467-7376 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Submittal Criteria Form Required for Single Family or Duplex Residences (Use Commercial form for lots with 3+ dwelling units or new residential tracts) Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification. Project Information  New Single Family Residence/Duplex  Addition/Remodel  ADU  Other Address: Unit #: City or Unincorporated County Area: ZIP: Scope of Work: Existing Area: Area to be Added: Total Resulting Area: Stories: Area Added in Past 2 Years (excluding this project): Yes No Questionnaire OCFA Plan Type if “Yes” 1.   New – Is this a new single family residence or duplex? *(PR160) Residential Site with Water Availability (PR400-402) Fire Sprinkler 2.   ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has fire sprinklers or a house that will have fire sprinklers added as part of this project? (PR400-402) Fire Sprinkler 3.   Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire sprinkler retrofit based on a threshold set by local ordinance? (PR400-402) Fire Sprinkler 4.   Distance – Is the most remote portion of the addition, ADU or other detached structure greater than 140-feet from the fire access roadway? *(PR160) Residential Site 5.   Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non- sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all enclosed spaces, such as garages, stairs, and detached structures separated by less than 10-feet? *(PR160) Residential Site with Water Availability 6.   Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed contractor to determine if a fire sprinkler modification is needed. (PR400-402) Fire Sprinkler 7.   Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold set by local ordinance? *(PR160) Residential Site (PR400-402) Fire Sprinkler 8.   Gate – Is a gate being installed across a driveway or road that is designated as a fire department access roadway, or a driveway or road that serves more than a single home/duplex? (PR180) Gate 9.   Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000 sf, and ADU’s). *(PR160) Residential Site *(PR172-174) Methane Test/Mitigation Plans 10.   Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation, or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as defined by the State, or (D) near an area that could be affected by a wildfire in the open space. *(PR125) Fuel Modification (PR182) Accessory Structure *OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals. Applicant Certification I certify, under penalty of perjury, under the laws of the State of California, that the information above is true: Print Name:_______________________________________ Signature:___________________________________________ Date:______________ Phone Number:_____________________________________________ Email:_____________________________________________________________ Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required. ______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes” and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination. For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100 SFR SaNTA 4 Name (First, MI, Last) Project Address City, State, Zip Code Name (First, MI, Last) Certificate of Compliance Payment of School Facility Fees Santa Ana Unified School District Building Owner Telephone H18et/Y1AFUI1fix 9q9 b2d W Orton Aye San-Io Ago--, CA 9 2 --d 3 Tract/Parcel CITY OF SANTA ANA Planning and Building Agency 5228 Approved FOR PERMIT ISSUANCE 4 9- 10tt2'CZ438 Telephone Use of Building (check) Type of Project (check) Residential [� Commercial ❑ Senior Housing ❑ New d Addition ❑ Alteration ❑ Description of Project �1ew -ached ,ADU Number of Square Feet of Residential Space 800 Sq.Ft x Number of Square Feet of Commercial Space Sq.Ft x $ S.R (Dev. Fee) (Dev. Fee) Total $ 4,1'Nb.00 Total $ The above representations as to square footage are true. Applicant agrees that if it is later determined that such representations are not true, then this certificate shall automatically terminate, and the appropriate City/County shall be notified. Applicant is hereby noticed that any party filing a protest regarding the imposition of fees pursuant to Government Code Section 53080 must do so within 90 days from the payment of the fee. Applicant Nam (Please Print) Date Sign tore This certifies that the above -named Applicant has paid school facility fees in compliance with all existing and applicable sections of the Government Code and Education Code. �► 13 2 S S t Ana Unified School District Aut ized Representative Date DISTM UTION White - City/County Canary - Applicant Pink - Facilities