HomeMy WebLinkAbout4715 - 4717 W McFadden Ave - PlanGSPublisherVersion 0.0.100.100 4 7 1 5 & 4 7 1 7 W . M C F A D D E N A V E , S A N T A A N A , CA 9 2 7 0 4 N E W A D D I T I O N T O N E W A D U sheet title: sheet number: REVISIONS NO.DATE DESCRIPTION DESIGN DRAWN ISSUED APPROVED NS JT T 1 .0 TITLE SHEET N&NC 12 4 5 EA S T W A L N U T S T R E E T , ST E 11 2 PA S A D E N A , CA 91 1 0 6NEW ADDITION TO NEW ADU 4715 &4717 W . MCFADDEN AVE, SANTA ANA, CA 92704 AGENT/DESIGNER: N&NC NATHAN COFFEE 1245 EAST WALNUT STREET, STE 112 PASADENA , CA 91106 PH #: 626 -578 -5614 nathan @ ncaarchitects .com VICINITY MAP T1.0 ARCHITECTURAL ABBREVIATIONS STRUCTURAL: SAA STRUCTURAL ENGINEERING, INC. CONTACT: MIKITA SIVUSHENKA 22121 CLARENDON ST. UNIT 340 WOODLAND HILLS, CA 91367 PH #: (323) 448-4682 nick @ saaeng .com CONTACTS SCOPE OF WORK APPLICABLE CODES GENERAL NOTES SHEET INDEX & A .B . A .C . A .C .I. ACP A .D .A .A .G A .F .F . ALUM . A .P .A . A .Q .T . ARCH . A .S .T .M . BLK 'G B .N . BM . B .O .J . BUR BOTT .OR (B ) C C /L C .B .B . C .J . CLG . CLR . C .M .U . COL . CONC . CONN . CONST . CONST . JT . CONT . CONTR COMP C .T . DBL . DEG . DIA . OR 0 DIAG . DIM . DR . DWG (S ) EA . E .C . E .F . EL . E .N . E .O .C . E .O .E . EQ .OR = E .S . EXP . F .D . FDN . F .F . F .G . FLR . FIN . F .N . F .O .B . F .O .J . F .O .M . F .O .P . F .O .S . F .R .P . F .S . FT . FTG . GA . GB . G .C . GALV . G .I. GLB . H .D . HDR . HDW . HGR . HGT . OR (HT ) H .M . AND ANCHOR BOLT ASPHALTIC CONCRETE AMERICAN CONCRETE INSTITUTE ACOUSTIC CEILING PANEL AMERICANS WITH DISABILITIES ACT ACCESSIBILITY GUIDEUNES ABOVE FINISH FLOOR ALUMINUM AMERICAN PLYWOOD ASSOCIATION ABRASIVE QUARRY TILE ARCHITECTURAL AMERICAN SOCIETY FOR TESTING MATERIALS BLOCKING BOUNDARY NAIL BEAM BOTTOM OF JOIST BUILT UP ROOFING ВОТТОМ CONDUIT CENTER LINE CEMENTITIOUS BAKER BOARD CONTROL JOINT (COLD JOINT) CEILING CLEAR CONCRETE MASONRY UNIT COLUMN CONCRETE CONNECTION CONSTRUCTION CONSTRUCTION JOINT CONTINUOUS CONTRACTOR COMPACTED (ION ) CERAMIC TILE DOUBLE DEGREE DIAMETER DIAGONAL DIMENSION DOOR DRAWING (S ) EACH ELECTRICAL CONTRACTOR EACH FACE ELEVATION EDGE NAIL EDGE OF COUNTER EDGE OF EQUIPMENT EQUAL EACH SIDE EXPANSION FLOOR DRAIN FOUNDATION FINISHED FLOOR FLOAT GLASS FLOOR FINISH FIELD NAIL FACE OF BEAM FACE OF JOIST FACE OF MASONRY FACE OF POST FACE OF STUD FIBERGLASS REINFORCED PANEL FLOOR SINK FEET FOOTING GAUGE (GAGE ) GYPSUM BOARD GENERAL CONTRACTOR GALVANIZED GALVANIZED IRON GLU -LAMINATED BEAM HUB DRAIN HEADER HARDWARE HANG ER HEIGHT HOLLOW METAL HORIZ OR (H ) H .S .B . IN . INFO . INV . JT . OR (JNT ) JST . IB . OR (#) LG . MAT . MAX . M .B . MIN MISC . M .P .S . M .S .B . MTL NO . OR (#) N .T .S . O .C . OPNG . P . LAM PL P /L PLYWD . PR PSF . PSL Q .T . RAD . OR (R ) REINF . S .C . SCHED . SHT . SIM . SM SMS SPEC (S ) SQ . SQ . IN . SQ . FT . STD . STL . STRUCT . SUSP . SYM . (T ) TEMP . THK . T & G T .N . T .O .B . T .O .F . T .O .PL . T .O .S . T .O .W . TYP . U .B .C . U .O .N VERT . OR (V ) V .W .C . W / WD . W .G .B . WT . WWM . HORIZONTAL HIGH STRENGTH BOLT INCH INFORMATION INVERTED JOINT JOIST POUNDS LONG MATERIAL MAXIMUM MACHINE BOLT MINIMUM MISCELLANEOUS MODULAR PANELBOARD SYSTEM MAIN SWITCH BOARD METAL NUMBER NOT TO SCALE ON CENTER OPENING PLASTIC LAMINATE OR PARALLAM PLATE PROPERTY LINE PLYWOOD PAIR POUNDS PER SQ. FOOT POUNDS PER SQ. INCH QUARRY TILE RADIUS REINFORCEMENT SAW -CUT JOINT SCHEDULE SHEET SIMILAR SHEET METAL SHEET METAL SCREW SPECIFICATION (S ) SQUARE SQUARE INCH SQUARE FOOT STANDARD STEEL STRUCTURAL SUSPENDED SYMMETRICAL TOP TEMPERED (TEMPERATURE ) THICKNESS TONGUE & GROOVE TOE NAIL TOP OF BEAM TOP OF FOOTING TOP OF PLATE TOP OF SLAB TOP OF WALL TYPICAL UNIFORM BUILDING CODE UNLESS OTHERWISE NOTED VERTICAL VINYL WALL COVERING WITH WOOD WEATHER RESISTANT GYPSUM BOARD WEIGHT WELDED WIRE MESH CLIENT: CONTACT: Ruth P. Torres 4715&4717 W. MCFADDEN AVE SANTA ANA, CA 92704 PH #: 714 -328 -1893 cucaptorres 53@ gmail .com CODE TYPE BUILDING CODE: RESIDENTIAL CODE : PLUMBING CODE : ELECTRICAL CODE: MECHANICAL CODE: FIRE /LIFE SAFETY CODE: ENERGY CODE : GREEN BUILDING CODE: MUNICIPAL CODE : CODE MODEL 2022 CALIFORNIA BUILDING CODE (CBC ) 2022 CALIFORNIA RESIDENTIAL CODE (CRC ) 2022 CALIFORNIA PLUMBING CODE (CPC ) 2022 CALIFORNIA ELECTRICAL CODE (CEC ) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA GREEN BUILDING CODE (CALGREEN ) SANTA ANA MUNICIPAL CODE 1. IN THE EVENT OF DISCREPANCIES BETWEEN THE DRAWING OR SPECIFICATIONS IN THIS PACKAGE NOTIFY NS DESIGNS, IMMEDIATELY . 2. NS DESIGNS, IS NOT RESPONSIBLE OR HAVE CONTROL OR CHARGE OVER ACTS OR OMISSIONS, CONSTRUCTION MEANS, METHODS , TECHNIQUES , SEQUENCES OR PROCEDURES, OR FOR THE SAFETY PRECAUTIONS & PROGRAMS OF THE CONTRACTOR, SUBCONTRACTOR , OR ANY OTHER PERSONS PERFORMING WORK ON THE PROJECT. 3. NS DESIGNS, HAS NOT BEEN RETAINED FOR REVIEW, SUPERVISION OR ADMINISTRATION OF THE CONTRACT ,NOR THE CERTIFICATION OF PAYMENTS. CONSTRUCTION COORDINATOR SHALL BE OWNER'S REPRESENTATIVE DURING CONSTRUCTION & UNTIL FINAL PAYMENT HAS BEEN MADE . THE OWNER'S REPRESENTATIVE WILL REVIEW THE PROJECT & RENDER NECESSARY DECISIONS FOR THE PROGRESS OF THE WORK. 4. CONTRACTOR IS RESPONSIBLE TO SEE IF THE WORK IN THE FIELD IS DONE IN ACCORDANCE WITH ALL THE CURRENT APPLICABLE NATIONAL, STATE, AND LOCAL CODES, ORDINANCES & REQUIREMENTS BY GOVERNING AGENCIES, WHETHER OR NOT SAID CODES, ORDINANCES , REQUIREMENTS, ETC... ARE SPECIFICALLY SHOWN ON DRAWINGS AND/OR CALLED FOR IN SPECIFICATIONS . 5. CONTRACTOR SHALL PROTECT ALL EXISTING ITEMS & FACILITIES TO REMAIN THROUGHOUT CONSTRUCTION. CONTRACTOR SHALL REPAIR AND/OR REPLACE AT CONTRACTORS EXPENSE, ANY EXISTING ITEMS AND FACILITIES TO REMAIN THAT ARE DAMAGED BY CONTRACTOR 'S OPERATIONS, TO THE SATISFACTION OF THE OWNER 'S REPRESENTATIVE. 6. GENERAL CONTRACTOR SHALL COORDINATE THE DELIVERY OF ALL OWNER SUPPLIED EQUIPMENT. THE CONTRACTOR IS RESPONSIBLE FOR THE INSPECTION OF EQUIPMENT AT TIME OF DELIVERY AND SHALL NOTIFY EQUIPMENT SUPPLIER OF ANY DEFICIENCIES OR DAMAGED EQUIPMENT AND ARRANGE FOR REPLACEMENT. 7. CONTRACTOR SHALL COMPLY WITH ALL PERTINENT LAWS, CODES , REGULATIONS, GOVERNING AGENCIES & MANUFACTURER SPECIFICATIONS, UNLESS GREATER REQUIREMENTS ARE INDICATED, OR ARE NECESSARY FOR SAFE WORKING CONDITIONS. 8. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING JURISDICTIONS AS REQUIRED FOR INSPECTIONS AND SHALL PAY INSPECTION FEES ASSOCIATED WITH THE WORK . 9. THE OWNER OR GENERAL CONTRACTOR SHALL APPLY, PAY FOR, AND OBTAIN ELECTRICAL, HVAC , MECHANICAL, AND PLUMBING PERMITS. 10 . THE GENERAL CONTRACTOR SHALL PROVIDE BARRICADES AND SAFETY SIGNS PER OSHA REQUIREMENTS . 11. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR OVERALL CONSTRUCTION SITE CLEANLINESS, INCLUDING PROVISION OF A DEBRIS BOX AT REGULAR SERVICING, REMOVAL OF ALL CONTRACTOR/SUBCONTRACTOR REFUSE AND DEBRIS, AND SWEEPING OF ENTIRE YARD AREA AT THE COMPLETION OF WORK . 12 . ALL PROCEDURES , TESTING , MATERIALS , SHOWN ON THE PLANS SHALL BE FURNISHED & INSTALLED BY THE GENERAL CONTRACTOR . UNLESS NOTED OTHERWISE IN THESE PLANS. EQUIPMENT OR M MATERIALS NOTED ONLY AS "FURNISHED BY OTHERS" SHALL BE INSTALLED BY THE GENERAL CONTRACTOR. T1.1 AS1.0 A1.1 A1.2 A1.3 TITLE SHEET GREEN BUILDING SHEET EXISTING ARCHITECTURAL SITE PLAN TO REMAIN EXISTING/DEMO FLOOR PLAN EXISTING ROOF PLAN TO REMAIN EXISTING EXTERIOR ELEVATIONS TO REMAIN ** NEW ADDITION 680 SQ .FT . TO NEW ATTACHED ADU INCLUDE DEMO OF EXISTING UNPERMTTED STRUCTURES NEW COVER PERGOLA OCCUPANCY GROUP : R -3 CONSTRUCTION TYPE: V-B FIRE SPRINKLERS: NO A2.1 A2.2 A2.3 PROPOSED FLOOR PLAN PROPOSED ELECTRICAL PLAN PROPOSED ROOF PLAN A2.4 A2.5 A3.1 PROPOSED EXTERIOR ELEVATIONS PROPOSED SECTION; WINDOW AND DOOR SCHEDULE ARCHITECTURAL DETAILS T1.2 GREEN BUILDING SHEET SITE INFORMATION: APN 0108-013-039 ADDRESS: 4703 W MCFADDEN AVE, UNIT C, SANTA ANA , CA 92704 LEGAL DESCRIPTION : TRACT NO. 10558, M.B. 448 - 24/25 LOT AREA: 7260 OCCUPANCY GROUP : R-3 CONSTRUCTION TYPE: V-B FIRE SPRINKLERS: NO EXISTING HOUSE AREA: 868 SQUARE FEET EXISTING COVERED PORCH: 66 SQUARE FEET EXISITING LOT COVERAGE: 934 SQ. FT. OR 12.8% PROPOSED ATTACHED ADU: 680 SQ. FT. PROPOSED LOT COVERAGE: 1614 SQ. FT. OR 22.2% T24.1 TITLE 24 COMPLIANCE T24.2 T24.3 T24.4 TITLE 24 COMPLIANCE TITLE 24 COMPLIANCE TITLE 24 COMPLIANCE ARCHITECTURAL S-0.10 S0.20 STRUCTURAL NOTES TYP. WOOD FRAMING DETAILS, DIAPHRAGM, SHEARWALL NAILING AND SCHEDULE TYP. WOOD FRAMING DETAILS. WALL CONSTRUCTION FOUNDATION PLAN S-0.11 S-0.12 S-0.13 S-0.14 S0.21 S0.31 S0.51 S-1 S-3 ROOF FRAMING PLAN FOUNDATION DETAILS ROOF FRAMING DETAILS STRUCTURAL NOTES STRUCTURAL NOTES STRUCTURAL NOTES STRUCTURAL NOTES TOPOGRAPHYC SURVEY SITE SITEBUS STOP RESPONSIBLE DESIGNER GSPublisherVersion 0.0.100.100 4 7 1 5 & 4 7 1 7 W . M C F A D D E N A V E , S A N T A A N A , CA 9 2 7 0 4 N E W A D D I T I O N T O N E W A D U sheet title: sheet number: REVISIONS NO.DATE DESCRIPTION DESIGN DRAWN ISSUED APPROVED NS JT A 1 .1 EXISTING/DEMO FLOOR PLAN N&NC 12 4 5 EA S T W A L N U T S T R E E T , ST E 11 2 PA S A D E N A , CA 91 1 0 6 (E) (E) (E)(E) (E) (E) (E) (E) (E) (E) (E)(E) (E) (E) (E) (E)(E)(E)(E) (E) (E) (E) 14 '-5" 13'-7" 4'-3" 3' 9'-6" 14 '-5" 9'-6" 2'-8" 3'-8"5'-6" 11 '-5" 9'-6"9'-6" 8' 9'-9" 3' 6'-2" 3'-9" 5' 6'-6" 18'-8" 10 '-5" 4'-8" 15 '-2" 6'-6" 3"13'-9"20'-1" 3'18'-8"12'-5" 6'-6" 7'-4" 1'-8" 2' 9'-6" 11 '-5" 11 '-5" 4'-8" 30 '-3" 6'-6" BEDROOM 1 8' CEILING CLOSET KITCHEN 8' CEILING DINING 8' CEILING BEDROOM 2 8' CEILING LIVING 8' CEILING HALL 8' CEILING storage BATHROOM 8' CEILING 2 UP 1 DOWN COVER PERGOLA slope roof PORCH slope roof 11 W/D 2 EXISTING WALL TO REMAIN EXISTING WINDOW LEGEND DEMOLITION NOTE: ALL DEMOLITION AND GRADING PERMITS WILL REQUIRE A PRECONSTRUCTION MEETING PRIOR TO COMMENCEMENT OF ANY DEMOLITION WORK AND A PROJECT SIGN MUST BE POSTED ON SITE. IF A SINGLE -FAMILY DWELLING 15 BEING DEMOLISHED THAT ISLOCATED ON A SLOPED LOT A TOPOGRAPHIC SURVEY IS REQUIRED TO BE PERFORMEDPRIOR TO THE DEMOLITION OF THE STRUCTURE. THIS MAY ALSO BE REQUIRED FOR AFLAT LOT AS DETERMINED BY THE BUILDING OFFICIAL. DOCUMENTS INDICATING RODENTAND INSECT ABATEMENT HAS BEEN PERFORMED MUST BE PRESENTED TO THE BUILDINGINSPECTOR PRIOR TO START OF DEMOLITION . RESIDENTIAL DEMOLITION NOTE: PARTIAL DEMOLITION OF A RESIDENTIAL STRUCTURE IN ASSOCIATION WITH A CONSTRUCTION PROJECT IS ONLY PERMITTED WHERE INDICATED ON THE APPROVED PLANS, ANY DEMOLITION WORK BEYOND THAT SHOWN ON THE APPROVED PLANS MAY RESULT IN A STOP WORK ORDER (CBC CHAPTER 1 SEC. 115) AND/OR REVOCATION OFTHE PERMIT (CBC CHAPTER 1 SEC. 105.6). MUNICIPAL CODE SEC. 10-1-1810 IF MORE THAN 50% OF THE STRUCTURE IS DEMOLISHED. KEYNOTES: DEMO EXISTING WINDOW DEMO EXISTING COVER PERGOLA 1 EXISTING WINDOW TO BE REMOVED EXISTING DOOR 2 - 1/4 " = 1 '-0" 1 EXISTING/DEMO FLOOR PLAN SCALE: NO R T H RESPONSIBLE DESIGNER GSPublisherVersion 0.0.100.100 4 7 1 5 & 4 7 1 7 W . M C F A D D E N A V E , S A N T A A N A , CA 9 2 7 0 4 N E W A D D I T I O N T O N E W A D U sheet title: sheet number: REVISIONS NO.DATE DESCRIPTION DESIGN DRAWN ISSUED APPROVED NS JT A 1 .2 EXISTING ROOF PLAN N&NC 12 4 5 EA S T W A L N U T S T R E E T , ST E 11 2 PA S A D E N A , CA 91 1 0 6 32 ' - 3 " 6' - 5 " 7" 13'-4"22'-1" 10 ' - 6 " 4' - 7 " 17 ' - 2 " 6' - 5 " 12'-6"20'-6"3'-1" 36'-1" 38 ' - 8 " 36'-1" 1' 1' 1' 1' 1' 1' 2'-6" 1' 1'1'1' 4:12 line of floor below line of floor below line of floor below line of floor below 4:12 4:12 4:12 4:12 4:12 1/4:12 2 LEGEND: ROOF SLOPE (E) ROOF TO REMAIN (E) ROOF TO REMOVE KEYNOTES: EXISTING ROOF TO REMAIN EXISTING ROOF TO REMOVE2 - 1/4 " = 1 '-0 " 1 EXISTING ROOF PLAN TO REMAIN SCALE : NO R T H RESPONSIBLE DESIGNER GSPublisherVersion 0.0.100.100 4 7 1 5 & 4 7 1 7 W . M C F A D D E N A V E , S A N T A A N A , CA 9 2 7 0 4 N E W A D D I T I O N T O N E W A D U sheet title: sheet number: REVISIONS NO.DATE DESCRIPTION DESIGN DRAWN ISSUED APPROVED NS JT A 1 .3 EXISTING EXTERIOR ELEVATIONS N&NC 12 4 5 EA S T W A L N U T S T R E E T , ST E 11 2 PA S A D E N A , CA 91 1 0 6 13 ' - 1 " 1' 8' 4' - 1 " 13 ' - 1 " 1' 8' 4' - 1 " 13 ' - 1 " 1' 8' 4' - 1 " 13 ' - 1 " 1' 8' 4' - 1 " (E)STUCCO TO REMAIN (E)ROOF TO REMAIN (E)ROOF TO REMAIN (E)ROOF TO REMAIN (E)ROOF TO REMAIN (E)ROOF TO REMAIN (E)ROOF TO REMAIN (E)ROOF TO REMAIN (E)STUCCO TO REMAIN (E)STUCCO TO REMAIN (E)STUCCO TO REMAIN (E)STUCCO TO REMAIN (E)WINDOW TO REMAIN(E)WINDOW TO REMAIN (E)WINDOW TO REMAIN (E)WINDOW TO REMOVE(E)STUCCO TO REMAIN (E)WINDOW TO REMAIN (E)WINDOW TO REMAIN(E)WINDOW TO REMAIN (E)WINDOW TO REMAIN (E)DOOR TO REMAIN (E)DOOR TO REMAIN (E)WINDOW TO REMOVE (E)WINDOW TO REMAIN (E)WINDOW TO REMAIN FIRST FLOOR HEIGHT EL.=+1'-0" RIDGE HEIGHT EL.=+13'-1" CEILING HEIGHT EL.=+9'-0" FIRST FLOOR HEIGHT EL.=+1'-0" RIDGE HEIGHT EL.=+13'-1" CEILING HEIGHT EL.=+9'-0" FIRST FLOOR HEIGHT EL.=+1'-0" RIDGE HEIGHT EL.=+13'-1" CEILING HEIGHT EL.=+9'-0" FIRST FLOOR HEIGHT EL.=+1'-0" RIDGE HEIGHT EL.=+13'-6" CEILING HEIGHT EL.=+9'-0" 124 124 124 124 124 12 4 12 4 12 4 12 4 12 4 12 1/4 121/4 12 1/4 1 /4 " = 1 '-0" 1 EXISTING FRONT ELEVATION SCALE:- GENERAL NOTES: ANY ADDITION OR CHANGES MADE TO THE APPROVED EXTERIOR ELEVATION DESIGN EITHER ON THE DRAWINGS OR DURING CONSTRUCTION WILL REQUIRE PLANNING DIVISION AND BUILDING DIVISION REVIEW AND APPROVAL AND MAY RESULT IN A DELAY OF THE PROJECT OR THE REMOVAL OF NON-APPROVED WORK. 1 /4 " = 1 '-0" 2 EXISTING/DEMO LEFT ELEVATION SCALE:- 1 /4 " = 1 '-0" 3 EXISTING BACK ELEVATION SCALE:- 1 /4 " = 1 '-0" 4 EXISTING RIGHT ELEVATION SCALE:- RESPONSIBLE DESIGNER GSPublisherVersion 0.0.100.100 4 7 1 5 & 4 7 1 7 W . M C F A D D E N A V E , S A N T A A N A , CA 9 2 7 0 4 N E W A D D I T I O N T O N E W A D U sheet title: sheet number: REVISIONS NO.DATE DESCRIPTION DESIGN DRAWN ISSUED APPROVED NS JT A2.1 PROPOSED FLOOR PLAN N&NC 12 4 5 EA S T WA L N U T ST R E E T , ST E 11 2 PA S A D E N A , CA 91 1 0 6 NEW DOORD1 CARBON MONOXIDE DETECTORCM SMOKE DETECTORSD MIN. 50 CFM MECHANICAL EXHAUST FAN - ENERGYSTAR WITH HUMIDISTAT FAN EXISTING STUD WALL TO REMAIN NEW STUD WALL NEW WINDOW W 1 W 1 W 2 W 3 W 4 W 5D1 D 2 CM SD FAN CM SD SD attic access 1 A 2 .5 1 A 2 .5 FAN SDSD SD SD SD CM D 3 D 4 D 5 D 6 WWF 7' - 1 0 " 7' - 1 0 " 5'-11"8'-5"4'-7"16'-10"8'-4" 2' - 5 " 8' - 5 " 4' - 9 " 3' 3' 3' 6' 5' 3' - 6 " 34'-1"10' (E) (E) (E)(E) (E) (E) (E) (E) 26 4 0 SH 26 4 0 SH (E) (E) (E) (E)(E)(E)(E) (E) (E) (E) 3030LS30684016LS4034LS 60 6 8 30 68 10068 3068 4668 14 '-5" 13'-7" 4'-3" 3' 9'-6" 14 '-5" 9'-6" 2'-8" 3'-8"5'-6" 11 '-5" 9'-6"9'-6" 8' 9'-9" 3' 6'-2" 3'-9" 5' 15 '-7" 10 '-1" 4'-8" 15 '-2" 44'-1" 7'-4" 1'-8" 2' 9'-6" 11 '-5" 11 '-5" 15 '-7" 29 '-11 " 3' 3'-2" 7'-11 " 11' 12 '-6" 2' 5' 5' 11' 2'-6" 2'-11 " 2'-6" 2'-7" 14' 4'10'-1"12'-6" 14 '-10 " 26'-7" 1"2'-4"1"1'2'-6"1'2'-6"2'1' BEDROOM 1 8' CEILING CLOSET KITCHEN 8' CEILING DINING 8' CEILING BEDROOM 2 8' CEILING LIVING 8' CEILING HALL 8' CEILING storage BATHROOM 8' CEILING 2 UP 1 DOWN PORCH slope roof qu e e n si z e ADU ENTRY TV wall (N) ADU BEDROOM 8' CEILING (N) ADU CLOSET (N) ADU LAUNDRY 8' CEILING (N) ADU BATHROOM 8' CEILING (N) ADU LIVING 8' CEILING 28 fridge30 range24 sink (N) ADU KITCHEN 8' CEILING W/D HEAT PUMP TANKLESS 21 0 3 1 0 SC 21 0 3 1 0 SC HEAT PUMP WATER HEATER GRAB BAR (N) MI N I SP L I T (N) MINI SPLIT 1-HOUR FIRE RATED WALL Aging-in-Place Design and Fall Prevention .CRC SECT R327.For new dwellings,at least one bathroom on the entry level shall be provided with reinforcement installed in accordance with CRC 327.1.1. Where there is no bathroom on the entry level ,at least one bathroom on the second or third floor of the dwelling shall comply with this section. 1.Reinforcement shall be solid lumber or other construction materials approved by the enforcing agency . 2.Reinforcement shall not be less than 2 by 8 inch (51 mm by 203 mm)nominal lumber. [11 /2 inch by 71/4 inch (38 mm by 184 mm actual dimension]or other construction material providing equal height . Reinforcement shall be located between 32 inches (812.8 mm)and 391/4 inches (997 mm)above the finished floor flush with the wall framing. 3.Water closet reinforcement shall be installed on both side walls of the fixture,or one side wall and the back wall. 4.Whower reinforcement shall be continuous where wall framing is provided. 5.Bathtub and combination bathtub/shower reinforcement shall be continuous on each end of the bathtub and the back wall.Additionally ,back wall reinforcement for a lower grab bar shall be provided located no more than 6 inches (152.4 mm)above the bathtub rim . See exceptions 1-5 per R327.1.1. NOTES : WHOLE HOUSE FANWWF and load capacity. with the bottom edge KEYNOTES: INSTALL NEW WALL INSTALL NEW EXTERIOR DOOR with theshold 1 1/2" max INSTALL NEW INTERIOR DOOR INSTALL NEW WINDOW INSTALL NEW CABINET INSTALL NEW KITCHEN SINK INSTALL NEW 300 CFM KITCHEN HOOD KITCHEN RANGE HOODS NOTE: THIS FAN IS TO BE USED FOR LOCAL VENT. EXHAUST. MINIMUM 300 CFM FAN TESTED AT A STATIC PRESSURE . 25 WC AND RATED @3 SONES OR LESS REQUIRED TO BE INSTALLED. AND MUST BE ATTACHED TO A MINIMUM 5" SMOOTH DUCT AND NO LONGER THAN 85'. SUBTRACT 15' INSTALL NEW FRIDGE INSTALL NEW BATHROOM FIXTURES LEGEND:GENERAL NOTES: 1. ALL CONSTRUCTION SHALL COMPLY WITH THE 2022 EDITION OF THE CRC, OR CBC, CMC, CPC, AND CEC AS ADOPTED AND AMENDED BY THE STATE OF CALIFORNIA IN TITLE 24 CCR AND THE CITY OF MUNICIPALITY AMENDMENTS. 2. SEPARATE PERMITS MAY BE REQUIRED FOR MECHANICAL , ELECTRICAL, PLUMBING, SHORING, GRADING, AND DEMOLITION 3, ALL PROPERTY LINES, EASEMENTS, AND EXISTING BUILDINGS HAVE BEEN INDICATED ON THIS SITE PLAN. 4. A SECURITY FENCE SHALL BE PROVIDED AROUND THE CONSTRUCTION AREA THAT SHALL BE INSTALLED PRIOR TO EXCAVATION AND /OR FOUNDATION TRENCHING. (BMC 9-1-2-3302.4) 5. WATER SHALL BE PROVIDED ON THE SITE AND USED TO CONTROL DUST. 6. TEMPORARY TOILET FACILITIES SHALL BE PROVIDED ON SITE. (BMC 9-1-2-3305.1) 7. THE FINISH GRADE SHALL SLOPE A MIN. OF 5%, OR 6"'H, TO POINT 10 FEET FROM BUILDING FOUNDATION, OR TO AN APPROVED ALTERNATE METHOD OF DIVERTING WATER AWAY FROM THE FOUNDATION. SWALES SHALL SLOPE A MINIMUM OF 2% (CBC 1804.4, CRC R401.3) 8. THE TOP OF THE EXTERIOR FOUNDATION SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER A MINIMUM OF 12 "H PLUS 2%. (CBC 1808.7.4, CRC R403.1.7.3 A. EQUIPMENT AND FURNITURE SHALL BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS B. EXTEND EXISTING DUCTS TO FEED NEW ADDITION C. INSTALL NEW HEADERS PER STRUCTURAL D. WALL COVERINGS IN SHOWERS AND-TUBS TOLBELCEMENT PLASTER, TILE, OR EQUAL TO 72" ABOVE DRAIN. ENCLOSURES MUST BE OF APPROVED SAFETY GLAZING AND DOORS MUST SWING OUT OF SHOWERS. WINDOWS IN ENCLOSURE WALLS SHALL DE LABELED SAFETY GLAZING WHEN LESS THAN 60" ABOVE DRAIN E. SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEAD SHALL BE FINISHED WITH A NONABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 6 FT ABOVE THE FLOOR. [CRC R307.2, CBC 1210.2.1] F. FIELD-CUTTING ENDS, NOTCHES, AND DRILLED HOLES OF PRESERVATIVE - TREATED WOOD SHALL BE TREATED IN THE FIELD IN ACCORDANCE WITH AWPA M4. [CRC R317-1.11] G. SLEEPING ROOMS MUST HAVE A WINDOW OR EXTERIOR DOOR FOR AN EMERGENCY EXIT, SILL HEIGHT NOT MORE THAN 44 INCHES ABOVE THE FLOOR, 5.7 SQUARE FEET OF OPEN ABLE AREA, 24 INCHES CLEAR OPENING HEIGHT, 20 INCHES CLEAR OPENING WIDTH AND SHALL OPEN DIRECTLY INTO A PUBLIC STREET, ALLEY YARD, OR EXIT COURT. H. MINIMUM WINDOW AREA SHALL BE 8% OF THE FLOOR AREA AND 50% OPERABLE. [CRC R303.1] I. NEW WINDOW OPENING FOR VENTILATION SHALL BE. A MINIMUM OF 4% OF THE FLOOR AREA. [CRC R303.1] J. BATHROOM OR SERVICE ROOM MINIMUM WINDOW AREAS SHALL NOT BE LESS THAN 3 SQUARE FEET AND 50% OPERABLE AND, PROVIDE A MECHANICAL VENTILATION SYSTEM EXHAUSTED TO THE OUTSIDE CAPABLE OF PROVIDING 50 CUBIC FEET PER MINUTE FOR INTERMITTENT VENTILATION 25 CUBIC FEET PER MINUTE FOR CONTINUOUS VENTILATION. [CRC R303.1] K. AN APPROVED SMOKE ALARM SHALL BE INSTALLED FOR NEW CONSTRUCTIONS AND ALTERATION. REPAIR OR ADDITIONS REQUIRING PERMIT EXCEEDING $1,000. [CRC R314.2.1, R314.2.21 L. BATTERY OPERATED SMOKE ALARMS PERMITTED IN EXISTING BUILDINGS WHERE NC CONSTRUCTION IS TAKING PLACE OR IN BUILDING UNDERGOING ALTERATION OR REPAIR THAT DO NOT RESULT IN THE REMOVAL OF INTERIOR WALLS OR CEILING FINISHES, UNLESS THERE IS AN ATTIC, CRAWL SPACE OR BASEMENT WHICH COULD PROVIDE ACCESS FOR WIRING. [CRC R314.6 EXCEPTIONS 1, 3] M. SMOKE ALARMS SHALL BE INTERCONNECTED SUCH THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS IN THE INDIVIDUAL DWELLING UNIT. [CRC R314.4] N. SMOKE DETECTORS SHALL BE HARDWIRED AND SHALL BE EQUIPPED WITH BATTERY BACKUP. [CRC 314.6] O. A. SMOKE ALARMS SHALL BE PROVIDED IN ALL NEW CONSTRUCTION LOCATED IN EACH SLEEPING ROOM, OUTSIDE EACH GROUP OF SLEEPING ROOM/ AREA, AND AT EACH TOP OF THE STAIRS, ADDITIONAL FLOOR OR BASEMENT LEVEL. [CRC R314.3] O.B. IN EXISTING DWELLINGS THE SMOKE ALARMS MAY BE BATTERY POWERED. P. AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED FOR NEW CONSTRUCTIONS AND ALTERATION. REPAIR OR ADDITIONS REQUIRING PERMIT EXCEEDING #1,000. [CRC R315.2.1, R315.2.2] Q. CO ALARMS SHALL BE HARDWIRED AND SHALL BE EQUIPPED WITH BATTERY BACKUP. [CRC 315.5] R. CO ALARMS SHALL BE LISTED FOR COMPLIANCE WITH UL2034, UL 217, UL2075, AND MAINTAINED PER NFPA 720. [CRC R315.1.1; R315.6.1, R315.6.2] S. CO ALARM AHLL BE INSTALLED OUTSIDE OF EACH SLEEPING AREA IN IMMEDIATE VICINITY OF THE BEDROOMS AND ON EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENT. [CRC R315.3] T. CO ALARMS SHALL BE INTERCONNECTED SUCH THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS IN THE INDIVIDUAL DWELLING UNIT. [CRC R315.7] U. IN EXITING DWELLING UNIT, Z CO ALARM IS PERMITTED TO BE BATTERY OPERATED WHERE REPAIR OR ALTERATION DO NOT RESULT IN THE REMOVAL OF A WALL OR CEILING FINISHES . [CRC R315.5 EXCEPTIONS 4] V. EVERY DWELLING UNIT SHALL HAVE AT LEAST ONE SWINGING , EXIT DOOR, MINIMUM CLEAR HEIGHT OF 6'-6" AND A MINIMUM CLEAR WIDTH OF 32" [CRC 311.2] W. CORRIDOR / HALL SHALL BE 36 INCHES MINIMUM CLEAR WIDTH. [CRC R311.3] X. MAX. PLUMBING FIXTURES FLOW RATE PER CALIFORNIA GREEN CODE [4.303] a. WATER CLOSETS 1.28 GPF b. SHOWERHEADS 1.8 GPM @ 80 PSI c. LAUNDRY SINK FAUCETS 1.2 GPM @ 60 PSI d. KITCHEN FAUCETS 1.8 GPM @ 60 PSI Y. CONTROL VALVES FOR SHOWER & TUB/ SHOWER SHALL BE OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE. Z. PROVIDE WATER HEATER ANCHOR STRAPS WITHIN THE UPPER AND LOWER 1/3 [CPC 508.2]. AA. BATHTUBS AND WHIRLPOOL BATHS SHALL BE PROVIDED WITH A TRAP DOOR OR ACCESS WITHIN 20 FEET OF THE PUMP [CPC 414.1] AB. POWER RECEPTACLES SHALL BE CHILD PROOF COVERED CEC 210.52 AC. ALL POWER AND LIGHTING OUTLETS IN FAMILY ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, HALLWAYS AND SIMILAR AREAS ARE TO BE PROTECTED BY A "COMBINATION AFCI BREAKER." KITCHENS, BATHROOMS, AND BASEMENTS ARE EXEMPT FROM THIS REQUIREMENT. AD. MINIMUM CLEAR WITH OF 36" FOR EXTERIOR STAIRS [CRC R311.7.1] BATHROOM NOTES: 1. THE WATER CLOSET SHALL HAVE A CLEARANCE OF 30 INCHES WIDE (15 INCHES ON CENTER) AND 24 INCHES IN FRONT. (CPC 402.5) WHERE THE WATER CLOSET (OR OTHER PLUMBING FIXTURE COMES INTO CONTACT WITH THE WALL OR FLOOR, THE JOINT SHALL BE CAULKED AND SEALED TO BE WATERTIGHT. (CPC 402.2) 2. SHOWER STALLS SHALL BE A MINIMUM FINISHED INTERIOR OF 1,024 SQUARE INCHES, BE CAPABLE OF ENCOMPASSING A 30 INCH DIAMETER CIRCLE. ANY DOORS SHALL SWING OUT OF THE ENCLOSURE HAVE A CLEAR OPENING OF 22 INCHES MINIMUM. (CPC 408.5, 408.6) CLOTHES DRYER NOTES: 1. A MINIMUM OF 4" MOISTURE EXHAUST DUCT MUST BE PROVIDED [MC 504.4.2] 2. DRYER EXHAUST CANNOT EXCEED 14 FT WITH A MAX OF TWO 90 DEGREE ELBOWS LCMC 504.4.2.1] 3. A FLEXIBLE DUCT CANNOT EXTEND MORE THAN 6 FT. AND CANNOT BE CONCEALED [CMC 504.4.2.2] PLUMBING NOTE: PER SECTION 301.1.1 CALGREEN AND CIVIL CODE 1101.3(c), ALL NON- COMPLIANT PLUMBING FIXTURES SHALL BE REPLACED WITH WATER-CONSERVING PLUMBING FIXTURES. NOTES: R327.1.1Reinforcement for grab bars. At least one bathroom on the entry level shall be provided with reinforcement installed in accordance with this section. Where there is no bathroom on the entry level, at least one bathroom on the second or third floor of the dwelling shall comply with this section. 2.Reinforcement shall not be less than 2 by 8 inch (51 mm by 203 mm) nominal lumber. [11/2 inch by 71/4 inch (38 mm by 184 mm) actual dimension] or other construction material providing equal height and load capacity. Reinforcement shall be located between 32 inches (812.8 mm) and 391/4 inches (997 mm) above the finished floor flush with the wall framing. 3. 3.Water closet reinforcement shall be installed on both side walls of the fixture, or one side wall and the back wall. 5. 5.Bathtub and combination bathtub/shower reinforcement shall be continuous on each end of the bathtub and the back wall. Additionally, back wall reinforcement for a lower grab bar shall be provided with the bottom edge located no more than 6 inches (152.4 mm) above the bathtub rim. R327.1.2Electrical receptacle outlet, switch and control heights. Electrical receptacle outlets, switches and controls (including controls for heating, ventilation and air conditioning) intended to be used by occupants shall be located no more than 48 inches (1219.2 mm) measured from the top of the outlet box and not less than 15 inches (381 mm) measured from the bottom of the outlet box above the finish floor. Doorbell buttons or controls, when installed, shall not exceed 48 inches (1219.2 mm) above exterior floor or landing, measured from the top of the doorbell button assembly. Where doorbell buttons integrated with other features are required to be installed above 48 inches (1219.2 mm) measured from the exterior floor or landing, a standard doorbell button or control shall also be provided at a height not exceeding 48 inches (1219.2 mm) above exterior floor or landing, measured from the top of the doorbell button or control. - 1/4" = 1'-0" 1 PROPOSED FLOOR PLAN SCALE: NO R T H GSPublisherVersion 0.0.100.100 4 7 1 5 & 4 7 1 7 W . M C F A D D E N A V E , S A N T A A N A , CA 9 2 7 0 4 N E W A D D I T I O N T O N E W A D U sheet title: sheet number: REVISIONS NO.DATE DESCRIPTION DESIGN DRAWN ISSUED APPROVED NS JT A2.2 PROPOSED ELECTRICAL PLAN N&NC 12 4 5 EA S T WA L N U T ST R E E T , ST E 11 2 PA S A D E N A , CA 91 1 0 6 S L.1 L.2 CM SD FAN CM SD SD L.1 L.1 L.1 L.1 L.1 L.1 L.1L.1 L.1L.1 L.1 L.1 L.1 L.1 L.1 L.1 S SS SS SSS SS AFCI AFCI AFCI AFCI AFCI AFCI AFCI AFCIAFCIAFCI AFCI GFI GFI AFCI GFI GFI GFI GFI 1 A 2 .5 1 A 2 .5 FAN SDSD SD SD SD CM WWF 240VHEAT PUMP TANKLESS HEAT PUMP WATER HEATER (N) MI N I SP L I T (N) MINI SPLIT L.1L.1 GFI GFI GFI GFI GFI S NEW SWITCH - BATHROOM SHALL HAVE AN OCCUPANCY SENSOR SWITCHES - FAN TO CONTINUE OPERATION FOR 10 MINUTES AFTER LIGHT SWITCHES OFF. HIGH EFFICACY EXTERIOR LED LIGHT- WITH ON/OFF SWITCH AS WELL AS PHOTOCONTROL AND AUTOMATIC TIME SWITCH CONTROL L.1 L.2 HIGH EFFICACY RECESSED LIGHT (40W LED) HIGH EFFICACY WATER-RESISTANT RECESSED LIGHT WALL SCONCE OUTSIDES PENDANT LIGHTP LEGEND NEW DOORD1 CARBON MONOXIDE DETECTORCM SMOKE DETECTORSD MIN. 50 CFM MECHANICAL EXHAUST FAN - ENERGYSTAR WITH HUMIDISTAT FAN EXISTING STUD WALL TO REMAIN NEW WINDOW NEW STUD WALL W 1 ALL POWER AND LIGHTING OUTLETS IN FAMILY ROOMS , PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS , HALLWAYS AND SIMILAR AREAS ARE TO BE PROTECTED BY A "COMBINATION AFCI BREAKER." KITCHENS, BATHROOMS, AND BASEMENTS ARE EXEMPT FROM THIS REQUIREMENT. 1 HOUR FIRE RATED WALL WHOLE HOUSE FAN WWF GENERAL NOTES: A. PANEL LOCATIONS PANELS SHALL NOT BE LOCATED IN THE VICINITY OF EASILY IGNITABLE MATERIAL, SUCH AS CLOTHES CLOSETS LCEC 240-24(D), OR IN BATHROOMS [CEC 240- 24(E)]. В. NON-METTALIC SHEATHED CABLE [CEC 334] NON-METALLIC SHEATHED CABLE SHALL BE: 1. PROTECTED BY RIGID METAL CONDUIT, INTERMEDIATE METAL CONDUIT , ELECTRICAL METALLIC TUBING, SCHEDULE 80 PVC CONDUIT, TYPE RTRC MARKED WITH THE SUFFIX -XW, OR OTHER MEANS WHEN CABLE IS EXPOSED OR SUBJECT TO PHYSICAL DAMAGE. [CEC 334.15(B)] 2. ROTECTED BY A 1/16-INCH STEEL PLATE OR SLEEVE OR BE NOT LESS THAN 1-1/4 INCH FROM THE NEAREST EDGE OF THE FRAMING MEMBER, WHEN INSTALLED THROUGH FRAMING MEMBERS. STEEL PLATES OR SLEEVES ARE REQUIRED ON ALL DOUBLE SHEAR WALLS WHEN CABLE IS INSTALLED EITHER THROUGH OR PARALLEL TO FRAMING MEMBERS [CEC 334.17, 300.4]. 3. PROTECTED BY GUARD STRIPS WITHIN 6 FEET OF AN ATTIC ACCESS WHEN NO PERMANENT STAIRS OR LADDERS ARE PROVIDED [CEC 334.23, 320.23] . 4. PROTECTED BY GUARDI STRIPSLINTTHETENTIRE ATTIC WHENTPERMANENT STAIRS OR LADDERS ARE PROVIDED. ACCESS PANELS OR DOORS FROM THE SECOND FLOOR INTO THE ATTIC ARE CONSIDERED PERMANENT ACCESS AND GUARD STRIPS ARE REQUIRED IN THE ENTIRE ATTIC [CEC 320.23]. 5. HAVE A BENDING RADIUS NOT LESS THAN 5 TIMES THE DIAMETER OF THE CABLE [CEC 334.24]. 6. SUPPORTED AT INTERVALS NOT EXCEEDING 4-1/2 FEET AND WITHIN 12''H OF EVERY OUTLET BOX, JUNCTION BOX, CABINET OR FITTING [CEC 334.30]. C. CIRCUITS AND RECEPTACLES 1. TAMPER-RESISTANT RECEPTACLES SHALL BE INSTALLED AS SPECIFIED IN DWELLING UNITS IN ALL AREAS SPECIFIED IN 210.52 AND 550.13. [CEC 406.12] 2. RECEPTACLES SHALL BE INSTALLED SO THAT NO POINT ALONG THE FLOOR LINE IN ANY WALL SPACE IS MORE THAN 6 FT. FROM AN OUTLET, INCLUDING ANY WALL SPACE 2 FT. WIDE OR GREATER. NOTE: A FIXED PANEL OF A SLIDING GLASS DOOR IS CONSIDERED WALL SPACE. [CEC 210.52(A)]. 3. IN KITCHENS, BREAKFAST ROOMS, PANTRIES AND DINING ROOMS A MINIMUM OF 2-20A CIRCUITS SHALL BE PROVIDED [CEC 210.11(C)(1)]. COUNTER SPACE RECEPTACLES SHALL BE GFCI [CEC 210.8(A)] AND INSTALLED: - AT EACH WALL COUNTER SPACE THAT IS 12 IN. OR GREATER [CEC 210.52(C)(1)] : - NO MORE THAN 48 IN. OC. [CEC 210.52 (C)(1)]; - MAXIMUM 24 IN. FROM THE END OF THE COUNTER [CEC 210.52 (C)(1)]; - MAXIMUM 20 IN. ABOVE COUNTER SURFACE [CEC 210.52(C)(5)] -ON ISLAND COUNTER SPACES (ONE RECEPTACLE MIN.) NOT MORE THAN 12 IN. BELOW COUNTER SURFACE [CEC 210.52 (C)(5) EXCEPTION]. AN ISLAND WITH LESS THAN 12*H BEHIND A RANGE TOP OF SINK IS CONSIDERED AS DIVIDING THE COUNTERTOP INTO TWO SEPARATE SPACES [CEC 210.52(C)(2)]. 4. BATHROOMS SHALL HAVE A SEPARATE 20A CIRCUIT [CEC 210.11 (C)(3)] WITH AT LEAST ONE GFCI WALL RECEPTACLE WITHIN 36 IN. OF EACH BASIN [CEC 210.8(A)(1): CEC 210.52(D)]. 5, LAUNDRY ROOMS SHALL HAVE A SEPARATE 20A CIRCUIT WITH AT LEAST ONE RECEPTACLE SHALL BE PROVIDED [CEC 210.11(C)(2)]. ALL RECEPTACLES WITHIN 6 FT. OF THE SINK SHALL BE GFCI ICEC 210.8(A)(7)]. 6. IN GARAGES, AT LEAST ONE GFCI RECEPTACLE SHALL BE PROVIDED [CEC 210,52(G)]. ALL OTHER GARAGE RECEPTACLES EXCEPT THOSE DEDICATED TO AN APPLIANCE OR THAT ARE NOT READILY ACCESSIBLE SHALL BE GFCI. [CEC 210.8(A)(2)]. 7. IN HALLWAYS OF 10 FT. OR MORE IN LENGTH, AT LEAST ONE RECEPTACLE SHALL BE PROVIDED [CEC 210.52(H)]. 8. OUTDOOR OUTLETS SHALL BE GFCI [CEC 210.8(A) (3)]. ONE OUTLET SHALL BE INSTALLED AT THE FRONT OF THE DWELLING AND ONE AT THE REAR OF THE DWELLING. BALCONIES, DECKS, AND PORCHES THAT ARE ATTACHED TO THE DWELLING UNIT AND ARE ACCESSIBLE FROM INSIDE THE DWELLING UNIT SHALL HAVE AT LEAST ONE OUTLET, RECEPTACLES SHALL BE ACCESSIBLE AT GRADE LEVEL AND NOT MORE THAN 6-1/2 FT. ABOVE GRADE OR WALKING SURFACE [CEC 210.52 (E)] 9. ALL CRAWL SPACE RECEPTACLES SHALL BE GFCI [CEC 210.8(A)(4)] 10. ALL UNFINISHED BASEMENT RECEPTACLES SHALL BE GFCI UNLESS THEY ARE NOT READILY ACCESSIBLE OR ARE SERVICE A DEDICATED APPLIANCE [CEC 210.8(A) (5)]. 11. ALL RECEPTACLES WITHIN 6 FT. OF A WET BAR SHALL BE GFCI [CEC 210.8(4)(7)]. 12. ALL RECEPTACLES ON 15A OR 20A BRANCH CIRCUITS THAT SUPPLY FAMILY ROOMS , DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY COMBINATION- TYPE ARC-FAULT CIRCUIT INTERRUPTERS (AFCI), INCLUDING SWITCHED OUTLETS [CEC 210.12 (A)]. 13. ALL RECEPTACLES SERVING APPLIANCES OR MOTORS WITH A RATING OF 1 HP OR 6 AMPS SHALL BE ON A SEPARATE CIRCUIT . 14. FOR HVAC EQUIPMENT , A SEPARATE 15A OR 20A CIRCUIT WITH AN ACCESSIBLE RECEPTACLE AT THE EQUIPMENT SHALL BE PROVIDED WITHIN 25 FT. OF THE EQUIPMENT [CEC 210.63]. IF LOCATED IN AN UNDER-FLOOR AREA, THE RECEPTACLE SHALL BE GFCI [CEC 210.8(4)]. 15. BASEMENTS, GARAGES AND ACCESSORY BUILDINGS. FOR A ONEFAMILY DWELLING, AT LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED IN THE AREAS SPECIFIED IN 210.52(G)(1) THROUGH (3)/ THESE RECEPTACLES SHALL BE IN ADDITION TO RECEPTACLES REQUIRED FOR SPECIFIC EQUIPMENT. [CEC210.521 (1) GARAGES, IN EACH ATTACHED GARAGE AND IN EACH DETACHED GARAGE WITH ELECTRICAL POWER. THE BRANCH CIRCUIT SUPPLYING THIS RECEPTACLE(S) SHALL NOT SUPPLY OUTLETS OUTSIDE OF THE GARAGE, AT LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED FOR EACH CAR SPACE. (2)ACCESSORY BUILDINGS. IN EACH ACCESSORY BUILDING WITH ELECTRIC POWER. (3) BASEMENT. IN EACH SEPARATE UNFINISHED PORTION OF A BASEMENT . D. LIGHTING [CEC 210.70] 1. SWITCHED LIGHTING SHALL BE INSTALLED IN: - ALL HABITABLE ROOMS, BATHROOMS, HALLWAYS, AND STAIRWAYS AT EACH LEVEL , - GARAGES, - AT ALL OUTDOOR ENTRANCES AND EXITS, - IN ALL ATTICS, UNDER FLOOR AREAS, UTILITY ROOMS AND BASEMENTS USED FOR STORAGE - NEAR HVAC EQUIPMENT IN ATTIC, UNDER FLOOR AREAS, ROOMS OR BASEMENTS. WITH A SWITCH AT THE ACCESS POINT. 2. LIGHTING INSTALLED IN A CLOSET SHALL BE A SURFACE MOUNTED OR RECESSED FLUORESCENT FIXTURE OR A SURFACE MOUNTED INCANDESCENT FIXTURE WITH COMPLETELY ENCLOSED LAMPS OR RECESSED INCANDESCENT FIXTURE WITH COMPLETELY ENCLOSED LAMPS. SURFACE INCANDESCENT LIGHTING SHALL BE INSTALLED A MINIMUM OF 12 IN. FROM THE NEAREST POINT OF A STORAGE SPACE. SURFACE FLUORESCENT LIGHTING AND RECESSED LIGHTING SHALL BE INSTALLED A MINIMUM OF 6 IN. FROM THE NEAREST POINT OF A STORAGE SPACE. [CEC 410.16(C)] E. FANS EACH BATHROOM CONTAINING A BATHTUB, SHOWER, OR BATHTUB/SHOWER COMBINATION SHALL BE MECHANICALLY VENTILATED FOR PURPOSES OF. HUMIDITY CONTROL IN ACCORDANCE WITH THE CALIFORNIA MECHANICAL CODE AND THE CALIFORNIA GREEN BUILDING STANDARDS CODE. F. SMOKE ALARMS IN NEW CONSTRUCTION, SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING. THE WIRING SHALL BE PERMANENT AND INSTALLED WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED FOR OVERCURRENT PROTECTION [CRC R314.4, CBC 907.2.10,5]. CLOTHES DRYER NOTES: 1. A MINIMUM OF 4" MOISTURE EXHAUST DUCT MUST BE PROVIDED [MC 504.4.2] 2. DRYER EXHAUST CANNOT EXCEED 14 FT WITH A MAX OF TWO 90 DEGREE ELBOWS LCMC 504.4.2.1] 3. A FLEXIBLE DUCT CANNOT EXTEND MORE THAN 6 FT. AND CANNOT BE CONCEALED [CMC 504.4.2.2] PLUMBING NOTE: PER SECTION 301.1.1 CALGREEN AND CIVIL CODE 1101.3(c), ALL NON- COMPLIANT PLUMBING FIXTURES SHALL BE REPLACED WITH WATER-CONSERVING PLUMBING FIXTURES. NOTE: 1. INTERIOR STAIRWAYS SHALL BE PROVIDED WITH ARTIFICIAL LIGHT SOURCE LOCATED IN THE IMMEDIATE VICINITY OF EACH LANDING OF THE STAIRWAY, CAPABLE OF ILLUMINATING TREADS AND LANDINGS AT LEAST 1-FOOT CANDLE MEASURED AT THE CENTER OF TREADS AND, LANDINGS. (CRC R303.7, CBC 1204.4). BATHROOM NOTES: 1. THE WATER CLOSET SHALL HAVE A CLEARANCE OF 30 INCHES WIDE (15 INCHES ON CENTER) AND 24 INCHES IN FRONT. (CPC 402.5) WHERE THE WATER CLOSET (OR OTHER PLUMBING FIXTURE COMES INTO CONTACT WITH THE WALL OR FLOOR, THE JOINT SHALL BE CAULKED AND SEALED TO BE WATERTIGHT. (CPC 402.2) 2. SHOWER STALLS SHALL BE A MINIMUM FINISHED INTERIOR OF 1,024 SQUARE INCHES, BE CAPABLE OF ENCOMPASSING A 30 INCH DIAMETER CIRCLE. ANY DOORS SHALL SWING OUT OF THE ENCLOSURE HAVE A CLEAR OPENING OF 22 INCHES MINIMUM. (CPC 408.5, 408.6) PLUMBING NOTE: PER SECTION 301.1.1 CALGREEN AND CIVIL CODE 1101.3(c), ALL NON- COMPLIANT PLUMBING FIXTURES SHALL BE REPLACED WITH WATER-CONSERVING PLUMBING FIXTURES. NOTES: 9. Water Heating system (water heater) ˆ¢â‹â (Section 150.0(n)) a. Systems using gas or propane water heaters to serve individual dwelling units shall designate a space at least 2.5 feet by 2.5 feet wide and 7 feet tall suitable for the future installation of a heat pump water heater (HPWH) by meeting either A or B listed under Section 150.0(n). A. If the designated space is within 3 feet from the water heater: i. A dedicated 125 volt, 20 amp electrical receptacle that is connected to the electric panel with a 120/240 volt 3 conductor, 10 AWG copper branch circuit, within 3 feet from the water heater. Heat pump space heater (furnace) ready: System using gas furnace to serve individual dwelling units shall include a dedicated 240 volt, minimum 30 amps branch circuit wiring shall be installed within 3-ft from the furnace for a future heat pump space heater installation Electric cooktop ready: System using gas to serve individual dwelling units shall include the following shall include a dedicated 240 volt, minimum 50 amps circuit wiring shall be installed within 3-ft from the cooktop for a future electric cooktop installation. - 1/4" = 1'-0" 1 PROPOSED ELECTRICAL PLAN SCALE: NO R T H GSPublisherVersion 0.0.100.100 4 7 1 5 & 4 7 1 7 W . M C F A D D E N A V E , S A N T A A N A , CA 9 2 7 0 4 N E W A D D I T I O N T O N E W A D U sheet title: sheet number: REVISIONS NO.DATE DESCRIPTION DESIGN DRAWN ISSUED APPROVED NS JT A2.3 PROPOSED ROOF PLAN N&NC 12 4 5 EA S T WA L N U T ST R E E T , ST E 11 2 PA S A D E N A , CA 91 1 0 6 attic access 1 A 2 .5 1 A 2 .5 17 ' - 7 " 29 ' - 1 1 " 17 ' - 7 " 8' - 2 " 4' - 7 " 17 ' - 2 " 36'-1"10' 46'-1" 1' 1' 1' 1' 1' 2'-6" 1' 46'-1" 4:12 line of floor below line of floor below line of floor below line of floor below 4:12 4:12 4:12 4:12 line of floor belowline of floor below line of floor below 4:12 2 4:12 2 4:12 4:12 4:12 22 4:124:12 22ATTIC: 643 SQ.FT. ATTIC: 643 SQ.FT.ATTIC: 643 SQ.FT. ATTIC: 643 SQ.FT. 3 3 3 3 33 FI R E RE A T E D EA V E FIRE REATED EAVE FIRE REATED EAVE LEGEND: ROOF SLOPE EXISTING ROOF TO REMAIN NEW ROOF NEW ATTIC KEYNOTES: EXISTING ROOF TO REMAIN NEW "A" CLASS ROOF NEW O'HAGIN VENTS LOW PROFILE - "TAPERED" 98.5 SQ. IN NFVA ATTIC VENTILATION NOTES: VENT OPENINGS FOR ENCLOSED ATTICS, ENCLOSED EAVE SOFFIT SPACES, ENCLOSED RAFTER SPACES, AND UNDERFLOOR VENTS SHALL RESIST BUILDING IGNITION FROM THE INTRUSION OF BURNING EMBERS AND FLAME THROUGH THE VENT OPENINGS. VENT OPENINGS SHALL COMPLY WITH ONE OF THE FOLLOWING : A. LISTED VENT COMPLYING WITH ASTM E2886 OR B. PROTECTED BY CORROSION RESISTANT, NONCOMBUSTIBLE WIRE MESH WITH MIN, 1/16" AND MAX 1/8" OPENINGS. (706A.2; R337.6.2). VENTS SHALL NOT BE INSTALLED ON UNDERSITE OF EAVES AND CORNICES UNLESS ONE OF THE CONDITIONS SET FORTH IN SECTION 706A.3 OR R337.6.3 ARE MET. ROOFING: CLASS A TYPE: COOL ROOF SHINGLES - CRRC# 0668-0055 MANUFACTURE: CERTAINTEED COLOR: AGED CEDAR SOLAR REFLECTANCE: 0.24 - 3-YEAR THERMAL TRANSMITTANCE: 0.90 - 3-YEAR SRI: 24 - 3-YEAR RATING CLASS A ROOFING ICC/ESR - 1389 UL 790 (CLASS A FIRE RESISTANCE) MINIMUM SLOPE: 2:12 ROOF VENTILATION CALC: ATTIC AREA 1 - 643 SQ. FT. 1/150 CALCULATION: 643 / 150 = 4,3 4,3 SQ. FT. REQUIRED 5 SQ. FT. PROVIDED SEE PLAN FOR VENT LOCATION 1 VENT X 4,43 SQ.FT. FIRE DEPARTMENT NOTES: 1. ROOF VALLEY FLASHING SHALL BE NOT LESS THAN 0.019-INCH. (No. 26 GALVANIZED SHEET GAGE) CORROSION-RESISTANT METAL INSTALLED OVER A MINIMUM 36-INCH WIDE UNDERLAYMENT CONSISTING OF ONE LAYER OF No. 72 ASTM CAP SHEET MEETING RUNNING THE FULL LENGTH OF THE VALLEY. (R327.5.3 AND CBC 705A.3) SEE DETAIL 7 ON SHEET A3.1 FOR FIRE RATED EAVE DETAIL - 1/4" = 1'-0" 1 PROPOSED ROOF PLAN SCALE: NO R T H GSPublisherVersion 0.0.100.100 4 7 1 5 & 4 7 1 7 W . M C F A D D E N A V E , S A N T A A N A , CA 9 2 7 0 4 N E W A D D I T I O N T O N E W A D U sheet title: sheet number: REVISIONS NO.DATE DESCRIPTION DESIGN DRAWN ISSUED APPROVED NS JT A2.4 PROPOSED EXTERIOR ELEVATIONS N&NC 12 4 5 EA S T WA L N U T ST R E E T , ST E 11 2 PA S A D E N A , CA 91 1 0 6 W 3 W 4 W 5 D 1 D 2 W 1 W 2 1' 8' 4' - 1 " 13 ' - 1 " 1' 8' 4' - 1 " 13 ' - 1 " 1' 8' 4' - 1 " 13 ' - 1 " 1' 8' 4' - 1 " 12 ' - 1 1 " 1'-1" 3' - 5 " 3' - 5 " 1'-2" 3' - 4 " 3' - 4 " 2' - 1 0 " 3' - 1 0 " 2'-10" 2' - 1 0 " 3' - 1 0 " 2'-10" (E)WINDOW TO REMAIN(E)STUCCO TO REMAIN (E)ROOF TO REMAIN (E)ROOF TO REMAIN (E)ROOF TO REMAIN (E)ROOF TO REMAIN (E)ROOF TO REMAIN (E)STUCCO TO REMAIN (E)STUCCO TO REMAIN (E)STUCCO TO REMAIN (E)WINDOW TO REMAIN(E)WINDOW TO REMAIN (E)WINDOW TO REMAIN(E)WINDOW TO REMAIN (E)WINDOW TO REMAIN(E)WINDOW TO REMAIN (E)WINDOW TO REMAIN (E)DOOR TO REMAIN (N) NEW "A" CLASS ROOF TO MATCH EXISTING (N) NEW "A" CLASS ROOF TO MATCH EXISTING (N) NEW "A" CLASS ROOF TO MATCH EXISTING (N) NEW "A" CLASS ROOF TO MATCH EXISTING (N) NEW WINDOW (max 44" sill height) (N) NEW WINDOW (N) NEW DOOR (N) NEW WINDOW(N)STUCCO TO MATCH EXISTING (N) NEW "A" CLASS ROOF TO MATCH EXISTING (N) NEW "A" CLASS ROOF TO MATCH EXISTING (N) NEW DOOR (N)STUCCO TO MATCH EXISTING(N) NEW WINDOW (N) NEW WINDOW (N)STUCCO TO MATCH EXISTING (N)STUCCO TO MATCH EXISTING FIRST FLOOR HEIGHT EL.=+1'-0" RIDGE HEIGHT EL.=+13'-1" CEILING HEIGHT EL.=+9'-0" FIRST FLOOR HEIGHT EL.=+1'-0" RIDGE HEIGHT EL.=+13'-1" CEILING HEIGHT EL.=+9'-0" FIRST FLOOR HEIGHT EL.=+1'-0" RIDGE HEIGHT EL.=+13'-1" CEILING HEIGHT EL.=+9'-0" FIRST FLOOR HEIGHT EL.=+1'-0" RIDGE HEIGHT EL.=+13'-6" CEILING HEIGHT EL.=+9'-0" 124 124 124 12 4 12 4 12 4 12 4 12 1/4 12 4124 124 12 4 12 4124 124 12 4 1/4" = 1'-0" 1 PROPOSED FRONT ELEVATION SCALE:- GENERAL NOTES: ANY ADDITION OR CHANGES MADE TO THE APPROVED EXTERIOR ELEVATION DESIGN EITHER ON THE DRAWINGS OR DURING CONSTRUCTION WILL REQUIRE PLANNING DIVISION AND BUILDING DIVISION REVIEW AND APPROVAL AND MAY RESULT IN A DELAY OF THE PROJECT OR THE REMOVAL OF NON-APPROVED WORK. 1/4" = 1'-0" 2 PROPOSED LEFT ELEVATION SCALE:- 1/4" = 1'-0" 3 PROPOSED BACK ELEVATION SCALE:- 1/4" = 1'-0" 4 PROPOSED RIGHT ELEVATION SCALE:- GSPublisherVersion 0.0.100.100 4 7 1 5 & 4 7 1 7 W . M C F A D D E N A V E , S A N T A A N A , CA 9 2 7 0 4 N E W A D D I T I O N T O N E W A D U sheet title: sheet number: REVISIONS NO.DATE DESCRIPTION DESIGN DRAWN ISSUED APPROVED NS JT A2.5 PROPOSED SECTION; WINDOW AND DOOR SCHEDULE N&NC 12 4 5 EA S T WA L N U T ST R E E T , ST E 11 2 PA S A D E N A , CA 91 1 0 6 1' 8' 4' - 1 " 12 ' - 1 1 " (N) NEW "A" CLASS ROOF TO MATCH EXISTING (N) NEW "A" CLASS ROOF TO MATCH EXISTING FIRST FLOOR HEIGHT EL.=+1'-0" RIDGE HEIGHT EL.=+13'-1" CEILING HEIGHT EL.=+9'-0" 12 4124 124 12 4 (N) ADU BATHROOM (N) ATTIC (N) ADU LIVING (N) ADU KITCHEN (N)2"X4" DOUBLE TOP PLATE (N)STUCCO (N)R15 INSULATION (N)GYPSUM BOARD (N)2"X4" DOUBLE TOP PLATE (N)STUCCO (N)R15 INSULATION (N)GYPSUM BOARD (N)R38 INSULATION (N)RAISED FOUNDATION W/ R-19 INSULATION (N) FOUNDATION(N) FOUNDATION (N)R38 INSULATION (N)RAISED FOUNDATION W/ R-19 INSULATION (N)RAISED FOUNDATION W/ R-19 INSULATION WINDOW SCHEDULE MARK TO ROOM :NAME WIDTH HEIGHT HEAD HEIGHT FAMILY SWING W1 (N) ADU BEDROOM 2'-6"4'-0"8'-0"Window -Single-Hung W2 SHGC 0,23 U-FACTOR 0,3UP NOTES 0,23 0,38'-0" W3 0,23 0,34'-0"3'-4"8'-0"Window -Double-Sliding LEFT W4 (N) ADU BATHROOM 0,23 0,31'-6"8'-0"Window -LEFT W5 0,23 0,33'-0"8'-0"Window -Double-Sliding LEFT (N) ADU BEDROOM 2'-6"4'-0"8'-0"Window -Single-Hung UP (N) ADU BEDROOM 4'-0"Double-Sliding (N) ADU KITCHEN 3'-0" W 1 W 2 W 3 W 4 W 5 D 1 D 2 D 3 D 5 D 6D4 6'-8" 6' 6'-8" 3' 3'-8" 3' 3'4' 5'-2" 1'-6" 4' 3'-4" 3'-4" 2'-6" 2'-8" 4' 2'-6" 2'-8" 4' 2'-11 " 1'-9" 10'4'-6"3' 6'-8" 6'-8" 6'-8" 3' 6'-8" DOOR SCHEDULE MARK FUNCTION WIDTH HEIGHT FAMILY SWING D1 EXTERIOR 3'-0"6'-8"DOOR-EXTERIOR-HINGED RIGHT TO ROOM: NAME (N) ADU LIVING NOTES D2 EXTERIOR 6'-0"DOOR-EXTERIOR-SLIDER LEFT(N) ADU KITCHEN 1/4" = 1'-0" 1 1-1 SECTION SCALE:- GENERAL NOTES: ANY ADDITION OR CHANGES MADE TO THE APPROVED EXTERIOR ELEVATION DESIGN EITHER ON THE DRAWINGS OR DURING CONSTRUCTION WILL REQUIRE PLANNING DIVISION AND BUILDING DIVISION REVIEW AND APPROVAL AND MAY RESULT IN A DELAY OF THE PROJECT OR THE REMOVAL OF NON-APPROVED WORK. GLAZING NOTES: GLAZING IN THE FOLLOWING LOCATIONS SHALL BE SAFETY GLAZING CONFORMING TO THE HUMAN IMPACT LOADS OF SECTION R308.5 (SEE EXCEPTIONS) (R308.4) A. FIXED AND OPERABLE PANELS OF SWINGING , SLIDING AND BI-FOLD DOOR ASSEMBLIES. B. GLAZING IN AN INDIVIDUAL FIXED OPERABLE PANEL ADUACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN 24-INCH ARC OF EITHER VERTICAL EDGE OF THE FLOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE FLOOR OF WALING SURFACE. C. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL THAT MEETS ALL OF THE FOLLOWING CONDITIONS: ili. EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET. iiv. BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR. v. TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR. vi. ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE GLAZING D. GLAZING IN GUARDS AND RAILINGS. E. GLAZING IN ENCLOSURES FOR OR WALLS FACING HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS WHERE THE BOTTOM EDGE AS THE GLAZING IS LESS THAN 60 INCHES MEASURED VERTICALLY ABOVE ANY STANDING FOR WALKING SURFACE. F. GLAZING IN WALLS AND FENCES ADJACENT TO INDOOR AND OUTDOOR SWIMMING POOLS, HOT TUBS AND SPAS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 INCHES ABOVE A WALKING SURFACE AND WITHIN SO INCHES, MEASURED HORIZONTALLY AND IN STRAIGHT LINE OF THE WATER'S EDGE. G. GLAZING WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 36 INCHES ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE OF STAIRWAYS, LANDINGS BETWEEN FLIGHTS OF STAIRS AND RAMPS H. GLAZING ADJACENT TO THE LANDING AT THE BOTTOM OF A STAIRWAY WHERE THE GLAZING IS LESS THAN 36 INCHES ABOVE THE LANDING AND WITHIN 60 INCH HORIZONTAL ARC LESS THAN 180 DEGREES FROM THE BOTTOM TREAD NOSING (R304.2). I. SKYLIGHTS AND SLOPED GLAZING SHALL COMPLY WITH SECTION R308.6 NOTES: THE NERC TEMPORARY LABEL DISPLAYED ON WINDOWS AND SKYLIGHTS (INCL. TUBULAR) MUST REMAIN ON THE UNIT UNTIL FINAL INSPECTION HAS BEEN COMPLETED 1. ALL GLAZING TO BE LOW-E DUAL GLAZED GLASS - EXTERIOR FLOOR TO CEILING WINDOWS AND DOORS TO BE TEMPERED 2. WINDOWS LOCATED IN SHOWERS SHALL BE TEMPERED AND SPECIFIED FOR USE IN SHOWER (WET RATED). CONTRACTOR TO INSTALL SHOWER WATERPROOFING MEMBRANE OVER WINDOW JAMB AND CAULK COMPLETELY AROUND WINDOW/TILE JOINT 3. ALL NEW METAL FINISH TO MATCH EXISTING 4. ALL NEW WINDOWS TO MATCH WINDOW CONFIGURATION AND GLAZING COLOR 5. EXTERIOR WINDOWS AND DOORS SHALL HAVE A U-FACTOR OF 0.23 AND AN SHGC OF 0.3 6. DOOR AND WINDOW OPENINGS ON EAST AND WEST EXTERIOR WALLS MUST BE WITH 3/4- HOUR FIRE ASSEMBLIES. 2640SH 2640SH 4034LS 4016LS 3030LS 3068 6068 TEMPERED TEMPERED D3 INTERIOR 3'-0"DOOR-INTERIOR-HINGED RIGHT(N) ADU BATHROOM D4 INTERIOR 3'-0"DOOR-INTERIOR-HINGED LEFT(N) ADU BEDROOM D5 INTERIOR 4'-6"DOOR-INTERIOR-HINGED RIGHT (N) ADU LAUNDRY D6 INTERIOR 10'-0"DOOR-INTERIOR-SLIDER(N) ADU CLOSET 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 3068 4668 100683068 TEMPERED GSPublisherVersion 0.0.100.100 4 7 1 5 & 4 7 1 7 W . M C F A D D E N A V E , S A N T A A N A , CA 9 2 7 0 4 N E W A D D I T I O N T O N E W A D U sheet title: sheet number: REVISIONS NO.DATE DESCRIPTION DESIGN DRAWN ISSUED APPROVED NS JT A 3 .1 ARCHITECTURAL DETAILS N&NC 12 4 5 EA S T W A L N U T S T R E E T , ST E 11 2 PA S A D E N A , CA 91 1 0 6 WRAP TYVEK‚ INTO OPENING & TAPE TO SILL (ESP. @ CORNERS) USING TYVEK“FLEXWRAP‘ INSTALL TYVEK“FLEXWRAP‘ AROUND PERIMETER OF OPENING *SEAL ALL TYVEK‚ JOINTS AND PENETRATIONS WITH APPROVED TAPE. (ex. DUPONT CONTRACTOR TAPE). *FASTEN TYVEK‚ TO SHEATHING WITH LARGE HEAD NAILS OR USE NAILS WITH LARGE PLASTIC WASHER HEADS. (ex. DUPONT WRAPCAPS) *LOCAL LAWS, ZONING, AND BUILDING CODES VARY AND THEREFORE GOVERNS OVER MATERIAL SELECTION AND DETAILING SHOWN BELOW. MINIMALLY EXPANDING POLYURETHANE FOAM OR APPROVED CAULK (AROUND WINDOW RSO) LAP & TAPE TYVEK‚ AT JOINTS (UPPER SHEET OVER LOWER SHEET) WINDOW SILL DETAIL RESIDENTIAL WOOD FRAME STRUCTURE w/ WOOD SIDING GENERAL NOTES WINDOW WITH INTEGRAL MOUNTING FLANGE TYPICAL WALL STUCCO WOOD FURRING TYVEKâ HOMEWRAPâ 7/16" PLYWOOD SHEATHING 2"x WOOD STUDS w/ R-15 BATT INSULATION 1/2" GYPSUM BOARD CAULKING FASTEN TYVEK“FLEXWRAP‘ CORNER USING MECHANICAL FASTENER *SEAL ALL TYVEK‚ JOINTS AND PENETRATIONS WITH APPROVED TAPE. (ex. DUPONT CONTRACTOR TAPE). *FASTEN TYVEK‚ TO SHEATHING WITH LARGE HEAD NAILS OR USE NAILS WITH LARGE PLASTIC WASHER HEADS. (ex. DUPONT WRAPCAPS) *LOCAL LAWS, ZONING, AND BUILDING CODES VARY AND THEREFORE GOVERNS OVER MATERIAL SELECTION AND DETAILING SHOWN BELOW. GENERAL NOTES RESIDENTIAL WOOD FRAME STRUCTURE w/ WOOD SIDING (COOLING CLIMATE) WINDOW HEAD DETAIL MINIMALLY EXPANDING POLYURETHANE FOAM OR APPROVED CAULK (AROUND WINDOW RSO) WINDOW WITH INTEGRAL MOUNTING FLANGE INSTALL TYVEK‚ FLEXWRAP‘ OVER MOUNTING FLANGE. LAP TYVEK‚ & TAPE JOINTS. TYPICAL WALL STUCCO WOOD FURRING TYVEKâ HOMEWRAPâ 7/16" PLYWOOD SHEATHING 2"x WOOD STUDS w/ R-15 BATT INSULATION 1/2" GYPSUM BOARD GENERAL NOTES BASE OF WALL DETAIL *SEAL ALL TYVEK‚ JOINTS AND PENETRATIONS WITH APPROVED TAPE. (ex. DUPONT CONTRACTOR TAPE). *FASTEN TYVEK‚ TO SHEATHING WITH LARGE HEAD NAILS OR USE NAILS WITH LARGE PLASTIC WASHER HEADS. (ex. DUPONT WRAPCAPS) * FILL THE GAP BETWEEN THE SILL PLATE AND FOUNDATION WALL / CONCRETE WITH MOISTURE-RESISTANT SILL GASKET * FOUNDATION STEM WALL SHALL BE MIN 8" ABOVE GRADE LEVELS OR AT LEAST AS HIGH AS THE ADJOINING SLABS OR 4-IN. CONCRETE BARRIER SET OFF SHALL BE INSTALLED. RESIDENTIAL WOOD FRAME STRUCTURE w/ WOOD SIDING TYPICAL WALL STUCCO TYVEK‚ HOMEWRAP‚ 7/16" PLYWOOD SHEATHING 2"x WOOD STUDS w/ R-15 BATT INSULATION 1/2" GYPSUM BOARD CAULK TYVEK‚TO METAL FLASHING & CAULK METAL FLASHING TO CONCRETE & SECURE w/ STARTER STRIP 5.5" WEEP SCREED SEAL GASKET - TYPICAL SEAL FOR CONCRETE TO VIRGIN WOOD ANCHOR BOLT 6" MI N GRAVEL MI N 8" CAULK TYVEK‚TO METAL FLASHING & CAULK METAL FLASHING TO CONCRETE & SECURE w/ STARTER STRIP 5.5" WEEP SCREED - SEE DET. #2 SEAL GASKET - TYPICAL SEAL FOR CONCRETE TO VIRGIN WOOD ANCHOR BOLT 2" MI N GRAVEL BVS FIBER EXPANSION JOINT BOARD, TYPICAL SIDEWALK 2% SLOPE FOR DRAINAGE ROOF UNDERLAYMENT 1/2" ROOF SHEATHING ASPHALT SHINGLES (SLOPE 4/12) TYPICAL WALL STUCCO TYVEK HOMEWRAP 7/16" PLYWOOD SHEATHING 2"x4" WOOD STUDS w/ R-15 BATT INSULATION 1/2" GYPSUM BOARD RAFTERS PER PLAN PLUG VULCAN VENT OPENING INSTALL 1/2" PLYWOOD W/ 2-LAYERS OF TYPE-X GYP. BOARD AT EAVES WITHIN 24" OF PROPERTY LINE DRIP EDGE BIRD STOP CEILING JOIST PER STRUCTURAL PLAN ROOF DETAIL SCALE NTS4 5 76 3 " = 1 '-0 " TYPICAL WALL - R-15 INSULATION SCALE : TYPICAL WALL STUCCO TYVEKâ HOMEWRAPâ 7/16" PLYWOOD SHEATHING 2"x4" WOOD STUDS w/ R-13 BATT INSULATION 1/2" GYPSUM BOARD - 2 1 -HOUR FIRE AND SOUND RATED WALL SCALE:NTS- 1 -NTS 3 TYPICAL GUTTER DETAIL SCALE : minimum No.26 galvanized sheet gage WHERE APPLICABLE RESPONSIBLE DESIGNER GSPublisherVersion 0.0.100.100 4 7 1 5 & 4 7 1 7 W . M C F A D D E N A V E , S A N T A A N A , CA 9 2 7 0 4 N E W A D D I T I O N T O N E W A D U sheet title: sheet number: REVISIONS NO.DATE DESCRIPTION DESIGN DRAWN ISSUED APPROVED NS JT AS 1 .0 EXISTING ARCHITECTURAL SITE PLAN N&NC 12 4 5 EA S T W A L N U T S T R E E T , ST E 11 2 PA S A D E N A , CA 91 1 0 6 47 ' - 7 " 9' - 1 0 " 18 ' - 3 " 6' - 1 0 " 4'-2"11'-6"3'11'-1"4'-6"12'-5"18'-8"3'19'-7" 4'-2"11'-6"3'11'-1"4'-6"34'-1"19'-7" 19 ' - 1 " 30 ' - 3 " 6' - 6 " 11 ' - 9 " 7' - 3 " 7' - 8 " 19 ' - 1 " 30 ' - 3 " 18 ' - 3 " 7' - 3 " 7' - 8 " 3'-8" 11'-6"3'11'-1"4'-6" 3" 13'-9"20'-1"20'-2" 3'-8" 11'-6"3'11'-1"4'-6"34'-1"20'-2" 19 ' - 2 " 30 ' - 3 " 6' - 6 " 26 ' - 6 " 34'14'20'-1"19'-11" 3" 13'-9" 19 ' - 7 " 10 ' - 5 " 4' - 8 " 15 ' - 2 " 6' - 6 " 26 ' - 2 " 47 ' - 6 " 20 ' - 9 " 14 ' - 3 " 57 ' - 4 " 18 ' - 3 " 6' - 1 0 " 11'-6"3'11'-1"4'-6" PERGOLA TO BE REMOVED SHED TO BE REMOVED UNPERMITTED COVER PERGOLA PORCH EXISTING 1-STORY SINGLE FAMILY RESIDENCE NO SPRIKLERED (E) FE N C E (E) FENCE(E) FENCE(E) FENCE(E) FENCE (E) FE N C E (E) FE N C E (E) FE N C E (E) FE N C E (E) FE N C E (E) FE N C E (E) FE N C E (E) CONCRETE (E) CONCRETE (E) CONCRETE (E) CONCRETE (E) LANDSCAPE (E) LANDSCAPE (E) LANDSCAPE (E) LANDSCAPE (E) LANDSCAPE (E) LANDSCAPE PL 82 .5' W C A M I L L E S T 5% SL O P E 5% SL O P E 5% SL O P E 5% SL O P E 5% SLOPE 5% SLOPE 5% SLOPE 2% SLOPE 2% SL O P E 2% SL O P E 2% SL O P E 2% SL O P E 2% SLOPE W WA T K I N S W A Y S SAFFORD ST 2% SL O P E 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE PL 82 .5' PL 88' PL 88' 10 ' WI D E EA S E M E N T FO R P I P E L I N E S 1' WIDE EASEMENT SITE INFORMATION: GENERAL NOTES: 1. NO BASEMENT ON LOT 2. LANDSCAPING IS EXISTING TO REMAIN UNLESS OTHERWISE NOTED ON THE SITE PLAN 3. ALL TREES ARE EXISTING TO REMAIN LANDSCAPING NOTES: 1. EXISTING LANDSCAPING AND IRRIGATION CONTROLLER TO REMAIN DRAINAGE NOTES: 1. PROVISIONS SHALL BE MADE FOR CONTRIBUTORY DRAINAGE AT ALL TIMES 2. OWNER WILL MAINTAIN DRAINAGE DEVICES AND KEEP FREE OF DEBRIS. 3. AN EXCAVATION / ENCROACHMENT PERMIT IS REQUIRED FOR CONSTRUCTION AND/OR DISCHARGE OF DRAINAGE WITHIN PUBLIC ROAD R/W. 4. NO WORK IS ALLOWED WITHIN THE PROTECTED ZONE LOF TREES WITHOUT A TREE REPORT AND PERMIT 5. FINISHED FLOOR TO BE 8 INCHES ABOVE FINISHED GRADE 6. LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6" WITHIN THE FIRST 10FT (5% SLOPE). WHERE LOT LINES WALLS, SLOPES OR OTHER PHYSICAL BARRIER PROHIBITS 6" FALL WITHIN 10 FT, DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. [CRC R401.3, CBC 1804.4] 7. IMPERVIOUS SURFACES WITHIN 10 FT OF THE BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2% AWAY FROM THE BUILDING . [CRC R401.3 EXCEPTION, CBC 1804.4] LEGEND: (E) SFR CONCRETE LANDSCAPE SHED PERGOLA PORCH COVER PERGOLA (E) TREE SITE INFORMATION: APN 0108-013-039 ADDRESS: 4703 W MCFADDEN AVE, UNIT C, SANTA ANA , CA 92704 LEGAL DESCRIPTION : TRACT NO. 10558, M.B. 448 - 24/25 LOT AREA: 7260 OCCUPANCY GROUP : R-3 CONSTRUCTION TYPE: V-B FIRE SPRINKLERS: NO EXISTING HOUSE AREA: 868 SQUARE FEET EXISTING COVERED PORCH: 66 SQUARE FEET EXISITING LOT COVERAGE: 934 SQ. FT. OR 12.8% PROPOSED ATTACHED ADU: 680 SQ. FT. PROPOSED LOT COVERAGE: 1614 SQ. FT. OR 22.2% - 1 /8 " = 1 '-0 " 1 EXISTING ARCHITECTURAL SITE PLAN SCALE : NO R T H RESPONSIBLE DESIGNER GSPublisherVersion 0.0.100.100 4 7 1 5 & 4 7 1 7 W . M C F A D D E N A V E , S A N T A A N A , CA 9 2 7 0 4 N E W A D D I T I O N T O N E W A D U sheet title: sheet number: REVISIONS NO.DATE DESCRIPTION DESIGN DRAWN ISSUED APPROVED NS JT AS 1 .1 PROPOSED ARCHITECTURAL SITE PLAN N&NC 12 4 5 EA S T W A L N U T S T R E E T , ST E 11 2 PA S A D E N A , CA 91 1 0 6 4' - 8 " 77 ' - 1 0 " 34'-3"34'-1"19'-7" 34'-3"34'-1"19'-7" 4' 15 ' - 7 " 29 ' - 1 1 " 33 ' - 2 " 4' 45 ' - 6 " 33 ' - 2 " 33'-9" 3" 54' 33'-9"34'-1"20'-2" 4' 15 ' - 7 " 29 ' - 1 1 " 33 ' 34'14' 3" 13'-9" 4' - 4 " 15 ' - 7 " 10 ' - 1 " 4' - 8 " 15 ' - 2 " 32 ' - 8 " 82 ' - 6 " 82 ' - 6 " 10'10' 34'-2"34'-1"19'-10" 4' 1' - 1 " 9'-1" 3' - 1 " PORCH: 66 SQ.FT. (E)SFR: 868 SQ.FT. (E) FE N C E (E)FENCE(E)FENCE(E)FENCE(E)FENCE (E) FE N C E (E) FE N C E (E) FE N C E (E) FE N C E (E) FE N C E (E) FE N C E (E) FE N C E (E)CONCRETE (E)CONCRETE (E)CONCRETE (E)LANDSCAPE (E)LANDSCAPE (E)LANDSCAPE (E)LANDSCAPE (E)LANDSCAPE (E)LANDSCAPE PL 82 .5' W C A M I L L E S T 5% SL O P E 5% SL O P E 5% SL O P E 5% SLOPE 5% SLOPE 5% SLOPE 2% SLOPE 2% SL O P E 2% SL O P E 2% SL O P E 2% SL O P E 2% SLOPE W WA T K I N S W A Y S SAFFORD ST 2% SL O P E 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE PL 82 .5' PL 88' PL 88' NEW ADU 4715 680 SQ.FT. 10 ' WI D E EA S E M E N T FO R P I P E L I N E S SETBACK WH HEAT PUMP 1' WIDE EASEMENT TANKLESS HEAT PUMP WATER HEATER 5% SL O P E SITE INFORMATION: GENERAL NOTES: 1.NO BASEMENT ON LOT 2.LANDSCAPING IS EXISTING TO REMAIN UNLESS OTHERWISE NOTED ON THE SITE PLAN 3.ALL TREES ARE EXISTING TO REMAIN LANDSCAPING NOTES: 1.EXISTING LANDSCAPING AND IRRIGATION CONTROLLER TO REMAIN DRAINAGE NOTES: 1.PROVISIONS SHALL BE MADE FOR CONTRIBUTORY DRAINAGE AT ALL TIMES 2.OWNER WILL MAINTAIN DRAINAGE DEVICES AND KEEP FREE OF DEBRIS. 3.AN EXCAVATION / ENCROACHMENT PERMIT IS REQUIRED FOR CONSTRUCTION AND/OR DISCHARGE OF DRAINAGE WITHIN PUBLIC ROAD R/W. 4.NO WORK IS ALLOWED WITHIN THE PROTECTED ZONE LOF TREES WITHOUT A TREE REPORT AND PERMIT 5.FINISHED FLOOR TO BE 8 INCHES ABOVE FINISHED GRADE 6.LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6" WITHIN THE FIRST 10FT (5% SLOPE). WHERE LOT LINES WALLS, SLOPES OR OTHER PHYSICAL BARRIER PROHIBITS 6" FALL WITHIN 10 FT, DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. [CRC R401.3, CBC 1804.4] 7.IMPERVIOUS SURFACES WITHIN 10 FT OF THE BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2% AWAY FROM THE BUILDING . [CRC R401.3 EXCEPTION, CBC 1804.4] LEGEND: (N)ADU CONCRETE LANDSCAPE SHED PERGOLA PORCH (N)NEW ADDITION (E)TREE SITE INFORMATION: APN 0108-013-039 ADDRESS: 4703 W MCFADDEN AVE, UNIT C, SANTA ANA , CA 92704 LEGAL DESCRIPTION : TRACT NO. 10558, M.B. 448 -24/25 LOT AREA: 7260 OCCUPANCY GROUP : R-3 CONSTRUCTION TYPE: V-B FIRE SPRINKLERS: NO EXISTING HOUSE AREA: 868 SQUARE FEET EXISTING COVERED PORCH: 66 SQUARE FEET EXISITING LOT COVERAGE: 934 SQ. FT. OR 12.8% PROPOSED ATTACHED ADU: 680 SQ. FT. PROPOSED LOT COVERAGE: 1614 SQ. FT. OR 22.2% ALL NEW UTILITIES WILL BE UNDERGROUND PER SAMC SECTION 41-626 -1 /8 " = 1 '-0 " 1 PROPOSED ARCHITECTURAL SITE PLAN SCALE : NO R T H Not in use D II 1.32900 0.47400 1.06300 0.53700 DATE:11/14/2024 JOB NO: MLB24-1210 DESIGNED BY: HK CHECKED BY: GB DE S C R I P T I O N DA T E RE V BY 1 3 4 5 - 2 - - MLB CONSULTING AND ENGINEERING, INC 7918 FOOTHILL BLVD SUNLAND, CA 91040 (818) 521-6342 INFO@MLBENGINEERING.ORG 4703 W McFadden Ave Santa Ana, CA 92704 DATE:11/14/2024 JOB NO: MLB24-1210 DESIGNED BY: HK CHECKED BY: GB DE S C R I P T I O N DA T E RE V BY 1 3 4 5 - 2 - - MLB CONSULTING AND ENGINEERING, INC 7918 FOOTHILL BLVD SUNLAND, CA 91040 (818) 521-6342 INFO@MLBENGINEERING.ORG 4703 W McFadden Ave Santa Ana, CA 92704 STRUCTURAL - GENERAL NOTES GENERAL REQUIREMENTS GOVERNING CODE: THE DESIGN AND CONSTRUCTION OF THIS PROJECT IS GOVERNED BY THE “CALIFORNIA BUILDING CODE (CBC)”, 2022 EDITION, HEREAFTER REFERRED TO AS THE CBC, AS ADOPTED AND MODIFIED BY THE COUNTY OF LOS ANGELES, UNDERSTOOD TO BE THE AUTHORITY HAVING JURISDICTION (AHJ). REFERENCE STANDARDS: REFER TO CHAPTER 35 OF 2022 CBC. WHERE OTHER STANDINGS ARE NOTED IN THE DRAWINGS, USE THE LATEST EDITION OF THE STANDARD UNLESS A SPECIFIC DATE IS INDICATED. REFERENCE TO A SPECIFIC SECTION IN CODE DOES NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE ENTIRE STANDARD. DEFINITIONS: THE FOLLOWING DEFINITIONS COVER THE MEANINGS OF CERTAIN TERMS USED IN THESE NOTES: ·“ARCHITECT/ENGINEER” - THE ARCHITECT OF RECORD AND THE STRUCTURAL/CIVIL ENGINEER OF RECORD. ·“STRUCTURAL/CIVIL ENGINEER OF RECORD” (SER) OR (EOR) - THE STRUCTURAL/CIVIL ENGINEER WHO IS LICENSED TO STAMP & SIGN THE STRUCTURAL DOCUMENTS FOR THE PROJECT. THE SER IS RESPONSIBLE FOR THE DESIGN OF THE PRIMARY STRUCTURAL SYSTEM. ·“SUBMIT FOR REVIEW” - SUBMIT TO THE ARCHITECT/ENGINEER FOR REVIEW PRIOR TO FABRICATION OR CONSTRUCTION. ·“PER PLAN” - INDICATED REFERENCES TO THE STRUCTURAL PLANS, ELEVATIONS AND STRUCTURAL GENERAL NOTES. ·“ENGINEER OF RECORD”(EOR) - A PROFESSIONAL ENGINEER (PE OR SE), LICENSED IN THE STATE WHERE THE PROJECT IS LOCATED, (TYPICALLY THE SER). DOCUMENTS STAMPED AND SIGNED BY THE EOR SHALL BE COMPLETED BY OR UNDER THE DIRECT SUPERVISION OF THE EOR. ·“BIDDER-DESIGNED” - COMPONENTS OF THE STRUCTURE THAT REQUIRE THE GENERA; CONTRACTOR, SUBCONTRACTOR, OR SUPPLIER WHO IS RESPONSIBLE FOR THE DESIGN, FABRICATION AND INSTALLATION OF SPECIALTY-ENGINEERED ELEMENTS IDENTIFIED IN THE CONTRACT DOCUMENTS TO RETAIN THE SERVICES OF AN SSE. SUBMITTALS OF “BIDDER-DESIGNED” ELEMENTS SHALL BE STAMPED AND SIGNED BY THE SSE. SPECIFICATIONS: REFER TO THE PROJECT SPECIFICATIONS ISSUED AS PART OF THE CONTRACT DOCUMENTS FOR INFORMATION SUPPLEMENTAL TO THESE DRAWINGS OTHER DRAWINGS: REFER TO THE ARCHITECTURAL, MECHANICAL. ELECTRICAL, CIVIL, AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION INCLUDING BUT NOT LIMITED TO: DIMENSIONS, ELEVATIONS, SLOPES, DOOR AND WINDOW OPENINGS, NON-BEARING WALLS, STAIRS, FINISHES, DRAINS, WATERPROOFING, RAILINGS, ELEVATORS, CURBS, DEPRESSIONS, MECHANICAL UNIT LOCATIONS, AND OTHER NON-STRUCTURAL ITEMS. STRUCTURAL DETAILS: THE STRUCTURAL DRAWINGS ARE INTENDED TO SHOW THE GENERAL CHARACTER AND EXTENT OF THE PROJECT AND ARE NOT INTENDED TO SHOW ALL DETAILS OF THE WORK. USE ENTIRE DETAIL SHEETS AND SPECIFIC DETAILS REFERENCED IN THE PLANS AS “TYPICAL” WHEREVER THEY APPLY. SIMILARLY, USE DETAILS ON ENTIRE SHEETS WITH “TYPICAL' IN THE SAME NAME WHEREVER THEY APPLY. STRUCTURAL RESPONSIBILITIES: THE STRUCTURAL/CIVIL ENGINEER IS RESPONSIBLE FOR THEIR STRENGTH AND STABILITY OF THE PRIMARY STRUCTURE IN ITS COMPLETED FORM. COORDINATION: THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING DETAILS AND ACCURACY OF THE WORK; FOR CONFIRMING AND CORRELATING ALL QUANTITIES AND DIMENSIONS; FOR SELECTING FABRICATION PROCESSES; FOR TECHNIQUES OF ASSEMBLY; AND FOR PERFORMING WORK IN A SAFE AND SECURE MANNER. PRE-CONSTRUCTION MEETINGS: THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING PRE-CONSTRUCTION MEETINGS PRIOR TO COMMENCING WORK. PRE-CON MEETINGS, SCHEDULED APPROXIMATELY TWO WEEKS PRIOR FROM THE START OF THE RELEVANT WORK, ARE REQUIRED FOR THE FOLLOWING PHASES OF CONSTRUCTION: POST-TENSIONED SLABS, STRUCTURAL STEEL AND CONCRETE. ATTENDEES FOR PRE-CONSTRUCTION MEETING ARE TO INCLUDE CONTRACTOR, RELEVANT SUBCONTRACTORS, FABRICATORS, INSPECTORS, ARCHITECT/ENGINEER, AND REPRESENTATIVE OF THE AUTHORITY HAVING JURISDICTION WHERE REQUIRED. MEETING AGENDAS ARE TO INCLUDE REVIEW OF THE WORK SCOPE, PROJECT SCHEDULE RELEVANT TO THE WORK, CONTACT INFORMATION OF RESPONSIBLE PARTIES, INSPECTION POINTS, REVIEW OF MATERIALS AD ANY SPECIAL CASES OR ISSUES, PROCEDURES FOR CLARIFICATIONS IF REQUIRED, TESTING AND ACCEPTANCE, ETC. MEANS, METHODS AND SAFETY REQUIREMENTS: THE CONTRACTOR IS RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION AND ALL JOB RELATED SAFETY STANDARDS SUCH AS OSHA AND DOSH (DEPARTMENT OF OCCUPATIONAL SAFETY AND HEALTH). CONTRACTOR IS RESPONSIBLE TO ADHERE TO OSHA REGULATIONS. BOLTING AND FIELD WELDING AT ALL MEMBER CONNECTIONS IS TO BE COMPLETED PRIOR TO THE RELEASE OF THE MEMBER FROM THE HOISTING MECHANISM UNLESS REVIEWED AND APPROVED BY THE GENERAL CONTRACTOR'S TEMPORARY BRACING AND SHORING DESIGN ENGINEER. BRACING/SHORING DESIGN ENGINEER: THE CONTRACTOR SHALL AT HIS DISCRETION EMPLOY AN SSE, A REGISTERED PROFESSIONAL ENGINEER FOR THE DESIGN OF ANY TEMPORARY BRACING AND SHORING. TEMPORARY SHORING, BRACING: THE CONTRACTOR IS RESPONSIBLE FOR THE STRENGTH AND STABILITY OF THE STRUCTURE DURING CONSTRUCTION AND SHALL PROVIDE SHORING, BRACING AND OTHER ELEMENTS REQUIRED TO MAINTAIN STABILITY UNTIL THE STRUCTURE IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO BE FAMILIAR WITH THE WORK REQUIRED IN THE CONSTRUCTION DOCUMENTS AND THE REQUIREMENTS FOR EXECUTING IT PROPERLY. CONSTRUCTION LOADS: LOADS ON THE STRUCTURE DURING CONSTRUCTION SHALL NOT EXCEED THE DESIGN LOADS AS NOTED IN THE DESIGN CRITERIA & LOADS BELOW OR THE CAPACITY OF PARTIALLY COMPLETED CONSTRUCTION AS DETERMINED BY THE CONTRACTOR'S SSE FOR BRACING/SHORING. CHANGES IN LOADING: THE CONTRACTOR HAS THE RESPONSIBILITY TO NOTIFY THE SER OF ANY ARCHITECTURAL, MECHANICAL, ELECTRICAL, OR PLUMBING LOAD IMPOSED ONTO THE STRUCTURE THAT DIFFERS FROM, OR THAT IS NOT DOCUMENTED ON THE ORIGINAL CONTRACT DOCUMENTS (ARCHITECTURAL/STRUCTURAL/MECHANICAL/ELECTRICAL OR PLUMBING DRAWINGS). PROVIDE DOCUMENTATION OF LOCATION, LOAD, SIZE AND ANCHORAGE OF ALL UNDOCUMENTED LEADS IN EXCESS OF 400 POUNDS. PROVIDE MARKED-UP STRUCTURAL PLAN INDICATING LOCATIONS OF ANY NEW EQUIPMENT OR LOADS. SUBMIT PLANS TO THE ARCHITECT/ENGINEER FOR REVIEW PRIOR TO INSTALLATION. NOTE PRIORITIES: PLAN AND DETAIL NOTES AND SPECIFIC LOADING DATA PROVIDED ON INDIVIDUAL PLANS AND DETAIL DRAWINGS SUPPLEMENTS INFORMATION IN THE STRUCTURAL GENERAL NOTES. DISCREPANCIES: IN CASE OF DISCREPANCIES BETWEEN THE GENERAL NOTES, SPECIFICATIONS, PLANS/DETAILS OR REFERENCE STANDARDS, THE ARCHITECT/ENGINEER SHALL DETERMINE WHICH SHALL GOVERN. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER BEFORE PROCEEDING WITH THE WORK. SHOULD ANY DISCREPANCY BE FOUND IN THE CONTRACT DOCUMENTS, THE CONTRACTOR WILL BE DEEMED TO HAVE INCLUDED IN THE PRICE THE MOST EXPENSIVE WAY OF COMPLETING WORK, UNLESS PRIOR TO THE SUBMISSION OF THE PRICE, THE CONTRACTOR ASKS FOR A DECISION FROM THE ARCHITECT AS TO WHICH SHALL GOVERN. ACCORDINGLY, ANY CONFLICT BETWEEN THE CONTRACT DOCUMENTS SHALL NOT BE A BASIS FOR ADJUSTMENT IN THE CONTRACT PRICE. SITE VERIFICATION: THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE. CONFLICTS BETWEEN THE DRAWINGS AND ACTUAL SITE CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER BEFORE PROCEEDING WITH THE WORK. ADJACENT UTILITIES: THE CONTRACTOR SHALL DETERMINE THE LOCATION OF ALL ADJACENT UNDERGROUND UTILITIES PRIOR TO EARTHWORK FOUNDATIONS, SHORING, AND EXCAVATION. ANY UTILITY INFORMATION SHOWN ON THE DRAWINGS AND DETAILS IS APPROXIMATE AND NOT NECESSARILY COMPLETE. ALTERNATES: ALTERNATE PRODUCTS OF SIMILAR STRENGTH, NATURE AND FORM FOR SPECIFIED ITEMS MAY BE SUBMITTED WITH ADEQUATE TECHNICAL DOCUMENTATION (PROPER TEST REPORT, ETC.) TO THE ARCHITECT/ENGINEER FOR REVIEW. ALTERNATE MATERIALS THAT ARE SUBMITTED WITHOUT ADEQUATE TECHNICAL DOCUMENTATION OR THAT SIGNIFICANTLY DEVIATE FROM THE DESIGN INTENTS OF MATERIALS SPECIFIED MAY BE RETURNED WITHOUT REVIEW. ALTERNATES THAT REQUIRE SUBSTANTIAL EFFORT TO REVIEW WILL NOT BE REVIEWED UNLESS AUTHORIZED BY THE OWNER. MAIN WIND FORCE RESISTING SYSTEM Ultimate Design Wind Speed, VULT (MPH) Exposure Category Internal Pressure Coefficient Topographic Factor Wind Analysis Procedure Used: COMPONENT & CLADDING PRESSURES FOR DESIGN Wall Cladding, Typical Zone Wall Cladding, Edge Zone within 20 ft. of corners Roof Cladding, Middle Zone Roof Cladding, Edge Zone within 20 ft. of edge Roof Cladding, Corner Zone within 20 ft. of corners Cpi = Kzt = DESIGN CRITERIA Risk Category of Building per 2022 CBC Table 1604.5 = Site Classification per CBC 1613.3.2 & ASCE 7-16, CH. 20 Site Class = Seismic Design Category: Seismic Importance Factor per ASCE 7-16 Table 1.5-2 Spectral Response Acceleration (Short Period) Spectral Response Acceleration (1-Second Period) Spectral Design Response Coefficient (Short Period) Spectral Design Response Coefficient (1-Second Period) SDC = IE = SS = S1 = SDS = SD1 = SEISMIC FORCE RESISTING SYSTEMS: Light-frame (wood) sheathed with wood structural panels rated for shear resistance (Wood Shearwalls) Response Modification Factor System Overstrength Factor Deflection Amplification Factor Seismic Response Coefficient Redundancy Factor R = Ω = Cd = Cs = ρ = Special Reinforced Concrete Shearwalls R = Ω = Cd = Cs = ρ = Response Modification Factor System Overstrength Factor Deflection Amplification Factor Seismic Response Coefficient Redundancy Factor 6.5 2.5 4 1.3 5 2.5 5 1.3 SEIMIC DESIGN: DL (PSF) DESIGN DEAD & LIVE LOADS INSPECTIONS, QUALITY ASSURANCE, VERIFICATIONS AND TEST REQ's INSPECTIONS: FOUNDATIONS, FOOTINGS, UNDER SLAB SYSTEMS AND FRAMING ARE SUBJECT TO INSPECTION BY THE BUILDING OFFICIAL IN ACCORDANCE WITH CBC 110.3. CONTRACTOR SHALL COORDINATE ALL REQUIRED INSPECTIONS WITH THE BUILDING OFFICIAL. SPECIAL INSPECTIONS, VERIFICATIONS AND TESTS: SPECIAL INSPECTION, VERIFICATIONS AND TESTING SHALL BE DONE IN ACCORDANCE WITH CBC CHAPTER 17 AND THE STATEMENT OF SPECIAL INSPECTIONS HEREIN PER CBC SECTIONS 1704 AND 1705, INCLUDING 1705.11 FOR SEISMIC RESISTANCE FOR PROJECTS IN SEISMIC DESIGN CATEGORIES C , D, E AND F AS APPLICABLE. SPECIAL INSPECTION AGENCY AND SPECIAL INSPECTORS: OWNER SHALL RETAIN AN “APPROVED AGENCY” PER CBC 1703 TO PROVIDE SPECIAL INSPECTIONS FOR THE PROJECT, SPECIAL INSPECTORS SHALL BE QUALIFIED PERSONS PER CBC 1704.2.1. STATEMENT OF SPECIAL INSPECTIONS: SPECIAL INSPECTIONS AND TESTING PER CBC SECTIONS 1704 AND 1705 ARE REQUIRED FOR THE FOLLOWING: FABRICATION SHOP INSPECTION: WHERE OFF-SITE FABRICATION OF GRAVITY LOAD BEARING MEMBERS & ASSEMBLIES IS PERFORMED, SPECIAL INSPECTOR SHALL VERIFY THAT THE FABRICATOR COMPLIES WITH CBC 1704.2. SOILS & FOUNDATION CONSTRUCTION PER CBC SECTION 1705.6 ·PERIODIC INSPECTION OF SOILS EARTHWORK PER TABLE 1705.6 IS REQUIRED FOR: o FOOTING SOIL BEARING SURFACED PRIOR TO PLACING ANY REINFORCING STEEL o EXCAVATION DEPTH AND BEARING LAYER PRIOR TO PLACING ANY REINFORCING STEEL. o COMPACTED FILL MATERIAL CLASSIFICATION o SUBGRADE PREPARATION PRIOR TO FILLING ·CONTINUOUS INSPECTION PER TABLE 1705.6 IS REQUIRED FOR: o FILLING OPERATIONS TO SATISFY REQUIREMENTS OF CBC TABLE 1705.6 AND THE GEOTECHNICAL REPORT LISTED UNDER SOILS AND FOUNDATIONS SECTION o COMPACTED FILL DENSITY TESTING OF EACH LIFT THICKNESS AND MATERIAL CLASSIFICATION CONCRETE CONSTRUCTION PER CBC SECTION 1705.3 AND TABLE 1705.3 INCLUDING: ·PERIODIC INSPECTION REQUIRED FOR: o SIZE AND PLACEMENT OF ALL REINFORCING STEEL AND PT TENDONS PRIOR TO THE POUR o PLACEMENT CLEARANCES AROUND REINFORCING STEEL AND PT TENDONS AT EMBEDDED CONDUIT o PLACING AND SIZE OF CAST-IN-PLACE BOLTS AND EMBEDDED FABRICATIONS PRIOR TO THE POUR o SHAPE, LOCATION AND DIMENSIONS OD MEMBERS FORMED o USE OF THE REQUIRED DESIGN CONCRETE MIX o MAINTENANCE OF SPECIFIC CURING TEMPERATURE AND TECHNIQUES o VERIFICATION OF IN-SITU CONCRETE STRENGTH PRIOR TO REMOVAL OF SHORES AND FORMS FROM BEAMS AND STRUCTURAL SLABS o VERIFICATION OF IN-SITU CONCRETE STRENGTH TO STRESSING OF PT TENDONS ·CONTINUOUS INSPECTION REQUIRED DURING THE o PLACING OF REINFORCED CONCRETE FOR PROPER APPLICATION TECHNIQUES o PLACING CONCRETE AROUND CAST-IN-PLACE BOLTS AND EMBEDS o SAMPLING OF FRESH CONCRETE o DETERMINATIONS OF SLUMP, AIR CONTENT AND TEMPERATURE o GROUTING OPERATION OF POST-INSTALLED BOLTS AND EMBEDS o PT TENDON STRESSING SHOTCRETE CONSTRUCTION: PER CBC 1910 INCLUDING: ·CONTINUOUS INSPECTION REQUIRED DURING THE: o SHOTCRETE PLACEMENT FOR THE PRECONSTRUCTION TEST PANEL (IF REQUIRED BY THE AHJ OR THE EOR) o TAKING OF CORE SPECIMENS FOR CONSTRUCTION SPECIMENS o PLACING OF ALL PRODUCTION SHOTCRETE STRUCTURAL MASONRY PER CBC SECTION 1705.4 AND 1705.12 LEVEL A - MASONRY CONSTRUCTION PER TMS 402-11/ACI 530-11/ASCE 6-11 SECTION 1.19.1: ·PERIODIC INSPECTION REQUIRED FOR: o SIZE, GRADE, PLACEMENT AND TYPE OF REINFORCING STEEL AND CONNECTORS o PROPORTIONS OF SITE-PREPARED MORTAR o PROTECTION OF MASONRY DURING COLD WEATHER (TEMP. BELOW 40 DEGREES F) o PROTECTION OF MASONRY DURING HOT WEATHER (TEMP ABOVE 90 DEGREES F) o COMPLIANCE WITH REQUIRED INSPECTION PROVISIONS OF THE CONSTRUCTION DOCUMENTS AND THE APPROVED SUBMITTALS STRUCTURAL STEEL PER CBC 1704.2.5.1 A QUALIFIED SPECIAL INSPECTOR OF AN “APPROVED AGENCY” PROVIDING QUALITY ASSURANCE (QA) SPECIAL INSPECTIONS FOR THE PROJECT SHALL REVIEW AND CONFIRM THE FABRICATOR AND ERECTOR'S QUALITY CONTROL (QC) PROCEDURES FOR COMPLETENESS AND ADEQUACY RELATIVE TO AISC 360-10 CHAPTER N, THE AISC 303 CODE OF STANDARD PRACTICE, AWS D1.1-2010 STRUCTURAL WELDING CODE AND CURRENT CBC CODE REQUIREMENTS FOR THE FABRICATOR'S SCOPE WORK o QA AGENCY PROVIDING SPECIAL INSPECTION AND NONDESTRUCTIVE TESTING NDT PER AISC 360-10 SECTION N4 o VERIFY FABRICATOR AND ERECTOR QUALITY CONTROL PROGRAM PER AISC 360-10 SECTION N2 o VISUAL WELDING INSPECTION OF WELDS BY BOTH QC AND QA PERSONNEL SHALL BE PER TABLED LISTED IN AISC 360 SECTION N5 o INSPECTION TASKS FOR WELDING §PRIOR TO WELDING PER AISC 360-10 TABLE N5.4-1 §DURING WELDING PER AISC 360-10 TABLE N5.4-2 §AFTER WELDING PER AISC 360-10 TABLE N5.4-3 o NONDESTRUCTIVE TESTING (NDT) OF WELDS: §NON-DESTRUCTIVE WELDING (NDT) OF WELDED JOINTS PER AISC 360-10 N.5 §RISK CATEGORY FOR DETERMINATION OF EXTENT OF NDT PER AISC 360 N5.5B IS NOTED IN THE DESIGN CRITERIA AND LOADS SECTION OF THESE GENERAL REQUIREMENTS §NDT PERFORMED SHALL BE DOCUMENTED AND REPORTS SHALL} IDENTIFY THE TESTED WELD PIECE MARK AND LOCATION IN THE PIECE §FOR FIELD WORK, THE NDT REPORT SHALL IDENTIFY THE TESTED WELD BY LOCATION IN THE STRUCTURE, PIECE MARK AND LOCATION IN THE PIECE §FOR FIELD WORK, THE NDT REPORT SHALL IDENTIFY THE TESTED WELD BY LOCATION IN THE STRUCTURE, PIECE MARK AND LOCATION IN THE PIECE o INSPECTION TASKS FOR BOLTING PER AISC 360-10 SECTION N5.6 §PRIOR TO BOLTING PER AISC 360-10 TABLE N5.6-1 (NOT REQUIRED FOR SNUG-TIGHT JOINTS) §DURING BOLTING PER AISC 360-10 TABLE N5.6-2 (NOT REQUIRED FOR SNUG-TIGHT JOINTS) §AFTER BOLTING PER AISC 360-10 TABLE N5.6-3 o ADDITIONAL INSPECTION TASKS PER AISC 360-10 SECTION N5.7 o INSPECTION FOR COMPOSITE CONSTRUCTION SHALL BE DONE PER AISC 360-10 SECTION N6 LL (PSF)AREAOCCUPANCY OR USE Residential Uninhabitable attics without storage Uninhabitable attics with storage Private Rooms and Corridors serving them Balcony and Decks Roofs Ordinary flat, pitched, and curved roofs Stair and exitway ways One- and two-family dwellings only Misc. Handrails and guardrails 25 60 15 20 15 15 20 40 10 20 20 40 50 plf / 200 lbs30 Exterior walls Interior walls WOOD-FRAMED WALLS 19 14 (1)Top rail shall be designed to resist 50 PLF line load or 200 ib point load applied in any direction at any point. Intermediate rails (all those except the handrail), balusters and panel fillers shall be designed to withstand a horizontally applied normal load of 50 LB on an area not to exceed 1 ft square. These three loads are to be considered separately with worst case used for design. (2) Place 300lb concentrated load over 2”x2” area at any point to produce maximum stress. Area load and concentrated load are to be considered separately with worst case used for design (3) Need not apply concurrently with other handrail and guardrail loads; applied over not more than 1 square foot (4) Apply concentrated wheel load over 4.5”x4.5” square area WIND DESIGN: OCCUPANCY WOOD CONSTRUCTION PER CBC SECTION 1705.5 & 1705.11.2: ·PERIODIC INSPECTION REQUIRED FOR VERIFICATION OF: O SHEAR WALLS: ANCHOR BOLTS, HOLD DOWNS (HD) AND CONTINUOUS ROD TIE-DOWN SYSTEMS (TDS) INCLUDING SQUASH BLOCKS, LPT SHEAR CONNECTORS, STRAP CONNECTORS, BOUNDARY EDGE NAILING, PLATE NAILING, AND PANEL EDGE SHEAR NAILING FOR SIZE & SPACING WHERE FASTENER SPACING OF THE SHEATHING IS 4 INCHES OR LESS. O DIAPHRAGMS: BLOCKING, STRAP CONNECTIONS, BOUNDARY EDGE AND PANEL SHEAR NAILING SIZE & SPACING WHERE FASTENER SPACING OF THE SHEATHING IS 4 INCHES OR LESS O MOISTURE CONTENT OF WOOD STUDS, PLATES, BEAMS AND JOISTS O PROPER BOTTOM PLATES SIZES (2X AND 3X) AND PLATE WASHERS O ROOF TRUSS 'HURRICANE' CLIPS. POST-INSTALLED ANCHORS TO CONCRETE AND MASONRY: SHALL COMPLY WITH CBC SECTION 1703. INSPECTIONS SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS SET FORTH IN THE APPROVED ICC EVALUATION REPORT AND AS INDICATED BY THE DESIGN REQUIREMENTS SPECIFIED ON THE DRAWINGS. REFER TO THE POST INSTALLED ANCHORS SECTION OF THESE NOTES FOR ANCHORS THAT ARE THE BASIS OF THE DESIGN. SPECIAL INSPECTOR SHALL VERIFY ANCHORS ARE AS SPECIFIED IN THE POST INSTALLED ANCHORS SECTION OF THESE NOTES OR AS OTHERWISE SPECIFIED ON THE DRAWINGS. SUBSTITUTIONS REQUIRE APPROVAL BY THE SER AND REQUIRE SUBSTANTIATING CALCULATIONS AND CURRENT 2012 IBC RECOGNIZED ICC EVALUATION SERVICES (ES) REPORT. SPECIAL INSPECTOR SHALL DOCUMENT IN THEIR SPECIAL INSPECTION REPORT COMPLIANCE WITH EACH OF THE ELEMENTS REQUIRED WITHIN THE APPLICABLE ICC EVALUATION SERVICES (ES) REPORT INSPECTION SUBMITTALS: SPECIAL INSPECTION REPORTS SHALL BE PROVIDED ON A WEEKLY BASIS. FINAL SPECIAL INSPECTION REPORTS WILL BE REQUIRED BY EACH SPECIAL INSPECTION FIRM PER CBC 1704.2.4. SUBMIT COPIES OF ALL INSPECTION REPORTS TO THE ARCHITECT/ENGINEER AND THE AUTHORITY HAVING JURISDICTION FOR REVIEW STRUCTURAL OBSERVATION: STRUCTURAL OBSERVATION SHALL BE PROVIDED FOR STRUCTURES CLASSIFIED AS SEISMIC DESIGN CATEGORY D, E AND F IN ACCORDANCE WITH CBC SECTION 1704.5 AND SECTION 107.3.4. STRUCTURAL OBSERVATION SITE VISITS WILL BE AS FOLLOWS: PRIOR TO FIRST FOUNDATION POUR, DURING SHEAR WALL CONSTRUCTION, PRIOR TO EACH UNIQUE ELEVATED SLAB POUR , PRIOR TO THE FIRST MILD REINFORCED SLAB, PRIOR RO THE FIRST POST-TENSIONED SLAB AND SEVERAL PERIODIC VISITS THEREAFTER, PERIODICALLY DURING FLOOR AND ROOF FRAMING AND AFTER ROOF DIAPHRAGM IS COMPLETE PRIOR TO ROOFING CONTRACTOR RESPONSIBILITY: PRIOR TO ISSUANCE OF THE BUILDING PERMIT, THE CONTRACTOR IS REQUIRED TO PROVIDE THE AUTHORITY HAVING JURISDICTION A SIGNED, WRITTEN ACKNOWLEDGEMENT OF THE CONTRACTOR'S RESPONSIBILITIES ASSOCIATED WITH THE ABOVE SATEMENT OF SPECIAL INSPECTIONS ADDRESSING THE REQUIREMENTS IN CBC SECTION 1704.4 CONTRACTOR IS REFERRED TO CBC SECTIONS 1705.11.5 AND 1705.11.6 FOR ARCHITECTURAL AND MEP BUILDING SYSTEMS THAT MAY BE SUBJECT TO ADDITIONAL INSPECTIONS (BASED ON THE BUILDING'S DESIGNATED SEISMIC DESIGN CATEGORY LISTED IN THE CRITERIA), INCLUDING ANCHORAGE OF HVAC DUCTWORK CONTAINING HAZARDOUS MATERIALS, PIPING SYSTEMS AND MECHANICAL UNITS CONTAINING FLAMMABLE, COMBUSTIBLE OR HIGHLY TOXIC MATERIALS, ELECTRICAL EQUIPMENT USED FOR EMERGENCY OR STANDBY POWER, EXTERIOR WALL PANELS AND SUSPENDED CEILING SYSTEMS. PREFABRICATED CONSTRUCTION: ALL PREFABRICATED CONSTRUCTION SHALL CONFORM TO CBC SECTION 1703. SPECIAL INSPECTIONS (CBC 1705): SPECIAL INSPECTION SHALL BE COMPLETED BY A DEPUTY INSPECTOR LICENSED AND REGISTERED WITH THE GOVERNING BUILDING DEPT. CONCRETE OVER 2500 PSI ANCHORS INSTALLED IN CONCRETE DRIVEN DEEP FOUNDATIONS SMOKE CONTROL SYSTEM OTHER SHOTCRETE P P P C C C C P P/C C C C P/C * C: CONTINUOUS P: PERIODIC CBC 1705.3 POST INSTALLED ANCHORS / EPOXY CBC TABLE 1705.3 CBC TABLE 1705.3 CBC TABLE 1705.3 REINFORCING STEEL AND STEEL TENDONS CBC TABLE 1705.3 STRUCTURAL STEEL STRUCTURAL STEEL WELDING CBC 1705.2 , 1705.12.1 CBC 1705.2 HIGH STRENGTH BOLTING CBC 1705.2 MASONRY CONSTRUCTION CBC 1705.4 HIGH-LOAD DIAPHRAGMS CBC 1705.5.1 WOOD CONSTRUCTION CBC 1705.5, 1705.11.1 COLD-FORMED STEEL CBC 1705.11.2 CBC TABLE 1705.7 SPRAY-APPLIED FIRE RESISTIVE MATERIALS SOILS CBC TABLE 1705.6 CBC TABLE 1705.14 CBC TABLE 1705.18 REMARKSITEMSCODE REFERENCE TYPE SPECIAL INSPECTIONS SEE ALSO ICC APPROVAL SEE SOILS REPORT P/C P/C P SCOPE OF WORK PROJECT TEAM OWNER ARCHITECT CIVIL ENGINEER GEO ENGINEER ADU MLB CONSULTING AND ENGINEERING 7918 FOOTHILL BLVD. SUNLAND, CA 91040 Phone: (818) 521-6342 Phone: SURVEYOR Phone: APPLICABLE BUILDING CODES 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA ELECTRIC CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS AMENDMENTS PER LOCAL CITY ORDINANCE AMERICAN INSITUTE OF STEEL CONSTRUCTION, LATEST ADOPTED EDITION NDS WOOD DESIGN MANUAL, LATEST ADOPTED EDITION ASCE-7, LATEST ADOPTED EDITION AISC SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS ACI: BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY 2022 CBC 2022 CRC 2022 CEC 2022 CPC 2022 CMC 2022 CFC CALGreen AISC NDS, NDS SUPPLEMENT, SDPWS ASCE7-16 ACI 318-19 AISC 341-16 S-0.10 ST R U C T U R A L N O T E S DATE:11/14/2024 JOB NO: MLB24-1210 DESIGNED BY: HK CHECKED BY: GB DE S C R I P T I O N DA T E RE V BY 1 3 4 5 - 2 - - MLB CONSULTING AND ENGINEERING, INC 7918 FOOTHILL BLVD SUNLAND, CA 91040 (818) 521-6342 INFO@MLBENGINEERING.ORG 4703 W McFadden Ave Santa Ana, CA 92704 DATE:11/14/2024 JOB NO: MLB24-1210 DESIGNED BY: HK CHECKED BY: GB DE S C R I P T I O N DA T E RE V BY 1 3 4 5 - 2 - - MLB CONSULTING AND ENGINEERING, INC 7918 FOOTHILL BLVD SUNLAND, CA 91040 (818) 521-6342 INFO@MLBENGINEERING.ORG 4703 W McFadden Ave Santa Ana, CA 92704 SOILS AND FOUNDATIONS REFERENCE STANDARDS: CBC CHAPTER 18 "SOILS AND FOUNDATIONS." GEOTECHNICAL REPORT: PREPARED BY: NONE CONTRACTOR'S RESPONSIBILITIES: CONTRACTOR SHALL BE RESPONSIBLE TO REVIEW THE GEOTECHNICAL REPORT AND SHALL FOLLOW THE RECOMMENDATIONS SPECIFIIED THEREIN INCLUDING, BUT NOT LIMITED TO, SUBGRADE PREPARATIONS, PILE INSTALLATION PROCEDURES, GROUND WATER MANAGEMENT AND STEEP SLOPE BEST MANAGEMENT PRACTICES. GEOTECHNICAL SUBGRADE INSPECTION: THE GEOTECHNICAL ENGINEER SHALL INSPECT ALL SUB-GRADES ND PREPARE SOIL BEARING SURFACES, PRIOR TO PLACEMENT OF FOUNDATION REINFORCING STEEL AND CONCRETE. GEOTECHNIAL ENGINEERS SHALL PROVIDE A LETTER TO THE OWNER STATING THAT SOULS ARE ADEQUATE TO SUPPORT THE "ALLOWABLE FOUNDATION BEARING PRESSURE(S)" SHOWN BELOW. ASSUMED VALUES SHALL BE FIELD VERIFIED BY THE BUILDING OFFICIAL OR THE GEOTECHNICAL ENGINEER PRIOR TO PLACING CONCRETE. ADVERSE SOILS: IF ADVERSE SOIL CONDITIONS ARE ENCOUNTERED, A SOILS INVESITGATION REPORT MAY BE REQUIRED UNLESS ALREADY PROVIDED FOR THIS PROJECT. DESIGN SOIL VALUES: ALLOWABLE FOUNDATION BEARING PRESSURE* Continuous Footing Isolated Pad Footing D+L Short Term Allowable Bearing Surface NATURAL GRADE1,500 1,500 2,660 2,660 * The above bearing value(s) may be increased by 150 psf for each additional foot of footing depth to a maximum of 4,000 psf . The bearing capacity can be increased by one-third when considering short duration wind or seismic loads. LATERAL EARTH PRESSURE* Active EFP (pcf) 30 65 At-Rest EFP (pcf) LEVEL BACKFILL 2:1 BACKFILL 1.5:1 BACKFILL 43 55 65 65 FOOTINGS: FOOTING REQUIREMENTS Min. Width Cont. Ext. Ftg. Int. Ext. Ftg. Isolated Pad Footing 12" 12" Min. Depth1 24" 24" Min. Embed. Into Approved Weathered Bedrock Min. Embed. Into Approved Certified Fill 12" 12" 24" 24" 12"24"12"24" PASSIVE LATERAL PRESSURE (LBS. PER CUBIC FT.) - WITHIN WEATHERED BEDROCK OR FILL............................. 150 PCF - MAX. ALLOW. FOR WEATHERED BEDROCK......................... 4,000 PCF COEFFICIENT OF SLIDING FRICTION................................................. NONE FOOTING DEPTH:TOPS OF FOOTINGS SHALL BE AS SHOWN ON PLANS WITH VERTICAL CHANGES AS INDICATED WITH STEPS IN FOOTINGS; LOCATIONS OF STEPS SHOWN AND APPROXIMATE AND SHALL BE COORDINATED WITH THE CIVIL GRADING PLANS. FOUNDATIONS SHALL BE EMBEDDED PER SCHEDULE ABOVE OR AS OTHERWISE INDICATED BY THE GEOTECHNICAL ENGINEER OR BUILDING OFFICIAL. CAST-IN PLACE CONCRETE REFERENCE STANDARDS: CONFORM TO: (1) ACI-301-10 "SPECIFICATIONS FOR STRUCTURAL CONCRETE" (2) CBC CHAPTER 19 "CONCRETE" (3) ACI 318-11/318R-11 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE" (4) ACI 117-10 "SPECIFICATIONS FOR TOLERANCES FOR CONCRETE CONSTRUCTION AND MATERIALS FIELD REFERENCE: THE CONTRACTOR SHALL KEEP A COPY OF ACI FIELD REFERENCE MANUAL, SP-15, "STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE (ACI 301) WITH SELECTED ACI AND ASTM REFERENCES." CONCRETE MIXTURES: CONFORM TO ACI 301 SECTION 4 "CONCRETE MIXTURES" AND CBC SECTION 1904.3 MATERIALS: CONFORM TO ACI 301 SECTION 4.2.1 "MATERIALS FOR REQUIREMTNS FOR CEMENTITIOUS MATERIALS, AGGREGATES, MIXING WATER AND ADMIXTURES. SUBMITTALS: PROVIDE ALL SUBMITTALS REQUIRED BY ACI 301 SECTION 4.1.2. SUBMIT MIX DESIGNS FOR EACH MIX IN THE TABLE BELOW. SUBSTANTIATING STRENGTH RESULTS FROM PAST TEST SHALL NOT BE OLDER THAN 24 MONTHS PER ACI 318 SECTION 5.3. TABLE OF MIX DESIGN REQUIREMENTS MEMBER TYPE/ LOCATION STRENGTH f'c (psi) TEST AGE (DAYS) MAX. AGGREGATE EXPOSURE CLASS MAX. W/C RATIO AIR CONTENT NOTES (1-8 TYP. UNO) SLAB ON GRADE FOOTINGS ELEVATED SLABS AND BEAMS CONCRETE COLUMNS GRADE BEAMS SITE RETAINING WALLS PILES SHEAR WALLS 28 28 1" SHOTCRETE WALLS 2500 4000 BASEMENT WALLS 2500 4000 3000 4000 3/4" 4000 4000 3000 3000 TABLE OF MIX DESIGN REQUIREMENTS NOTES: 1. W/C RATIO : WATER-CEMENTATION MATERIAL RATIOS SHALL BE BE BASED ON THE TOTAL WEIGHT OF CEMENTATION MATERIALS. MAXIMUM RATIOS ARE CONTROLLED BY STRENGTH NOTED IN THE MIX DESIGN REQUIREMENTS AND DURABILITY REQUIREMENTS GIVEN IN ACI 318 SECTION 4.3. 2. CEMENTATION MATERIALS: 2.a. CEMENTATION MATERIAL TYPES SHALL CONFORM TO ACI 318 TABLE 4.3.1, BASED ON THE EXPOSURE CLASSES INDICATED. 2.b. THE USE OF FLY ASH, OTHER POZZOLANS, SILICA FUME, OR SLAG SHALL CONFORM TO ACI 318 SECTIONS 4.4.2. MAXIMUM AMOUNT OF FLY ASH SHALL BE 25% OF TOTAL CEMENTATION CONTENT UNLESS REVIEWED AND APPROVED OTHERWISE BY EOR. 2.c. FOR CONCRETE USED IN ELEVATED FLOORS, MINIMUM CEMENTATION-MATERIALS CONTENT SHALL CONFORM TO ACI 301 TABLE 4.2.2.1. ACCEPTANCE OF LOWER CEMENT IS CONTINGENT ON PROVIDING SUPPORTING DATA TO THE SER FOR REVIEW AND ACCEPTANCE. 2.d. CEMENTATION MATERIALS SHALL CONFORM TO THE RELEVANT ASTM STANDARDS LISTED IN ACI 318 SECTION 3.2.1 3. AIR CONTENT: CONFORM TO ACI 318 SECTION 4.4.1. MINIMUM STANDARDS FOR EXPOSURE CLASS ARE NOTED IN THE TABLE. IF FREEZING AND THAWING CLASS IS NOT NOTED. AIR CONTENT GIVEN IS THAT REQUIRED BY THE SER. TOLERANCE IS ±1-1/2%. AIR CONTENT SHALL BE MEASURED AT POINT OF PLACEMENT. 4. AGGREGATES SHALL CONFORM TO ASTM C33. 5. SLUMP: CONFORM TO ACI 301 SECTION 4.2.2.2. SLUMP SHALL BE DETERMINED AT POINT OF PLACEMENT. 6. CHLORIDE CONTENT: CONFORM TO ACI 318 SECTION 4.3.1. 7. NON-CHLORIDE ACCELERATOR: NON-CHLORIDE ACCELERATING ADMIXTURE MAY BE USED IN CONCRETE PLACED AT THE AMBIENT TEMPERATURES BELOW 50°F AT THE CONTRACTOR'S OPTION. 8. ACI 318, SECTION 4.2.1 EXPOSURE CLASSES SHALL BE ASSUMED TO BE F0, S0, P0, AND C0 UNLESS DIFFERENT EXPOSURE CLASSES ARE LISTED IN THE TABLE OF MIX DESIGN REQUIREMENTS THAT MODIFY THESE BASE REQUIREMENTS. 9. SHRINKAGE LIMIT: CONCRETE USED IN ELEVATED SLABS AND BEAMS SHALL HAVE A SHRINKAGE LIMIT OF 0.045% AT 28 DAYS MEASURED IN ACCORDANCE WITH ASTM C157. SUBMIT LABORATORY TEST RESULTS TO SER FOR APPROVAL PRIOR TO CONSTRUCTION. FORMWORK & RESHORING: CONFORM TO ACI 301 SECTION 2 "FORMWORK AND FORM ACCESSORIES." REMOVAL OF FORMS SHALL CONFORM TO SECTION 2.3.2 EXCEPT STRENGTH INDICATED IN SECTION 2.3.2.5 SHALL BE 0.75 f 'c. RESHORING SHALL CONFORM TO SECTION 2.3.3. IN ADDITION, MILD REINFORCEMENT (NON POST-TENSIONED) SLABS SHALL BE CONTINUOUSLY RESHORED FOR A MINIMUM OF 14 DAYS FOLLOWING PLACEMENT OF CONCRETE OR 7 DAYS AFTER CONCRETE HAS REACHED 0.75 f 'c, WHICHEVER IS LONGER. CONTRACTOR SHALL SUBMIT FORMWORK REMOVAL AND RESHORE INSTALLATION PROCEDURE AND DRAWINGS AS APPLICABLE SEALED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE WHERE THE PROJECT IS LOCATED FOR THE SER'S INFORMATION. MEASURING, MIXING AND DELIVERY: CONFORM TO ACI 301 SECTION 4.3. HANDLING, PLACING, CONSTRUCTING AND CURING: CONFORM TO ACI 301 SECTION 5. IN ADDITION, HOT WEATHER CONCRETING SHALL CONFORM TO ACI 305.1-06 AND COLD WEATHER CONCRETING SHALL CONFORM TO ACI 306.1-90. CONCRETE CURING: PROVIDE CURING COMPOUNDS FOR CONCRETE AS FOLLOWS. 1. USE MEMBRANE CURING COMPOUNDS THAT ARE COMPATIBLE WITH AND WILL NOT AFFECT SURFACES TO BE COVERED WITH FINISH MATERIALS APPLIED DIRECTLY TO CONCRETE. 2. APPLY CURING COMPOUNDS AT A RATE EQUIVALENT TO THE RATE OF APPLICATION AT WHICH CURING COMPOUND WAS ORIGINALLY TESTED FOR IN CONFORMANCE TO THE REQUIREMENTS OF ASTM C 309-07 AND THE MANUFACTURER'S RECOMMENDATIONS. 3. SLUMP: CONFORM TO ACI 301 SECTION 4.2.2.2. SLUMP SHALL BE DETERMINED AT POINT OF PLACEMENT. 4. USE CURING COMPOUND COMPATIBLE WITH AND APPLIED UNDER DIRECTION OF SYSTEM MANUFACTURER OF PROTECTIVE SEALER. 5. APPLY TWO SEPARATE COATS WITH FIRST ALLOWED TO BECOME TACKY BEFORE APPLYING SECOND. DIRECTION OF SECOND APPLICATION SHALL BE AT RIGHT ANGLES TO THE DIRECTION OF FIRST. CONCRETE REINFORCEMENT REFERENCE STANDARDS: CONFORM TO: 1. ACI 301-10 "STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE", SECTON 3 "REINFORCEMENT AND REINFORCEMENT SUPPORTS." 2. ACI SP-66-04 "ACI DETAILING MANUAL" INCLUDING ACI 315-99 "DETAILS AND DETAILING OF CONCRETE REINFORCEMENT." 3. CRSI MSP-09, 28TH EDITION, "MANUAL OF STANDARD PRACTICE." 4. ANSI/AWS D1.4 "STRUCTURAL WELDING CODE - REINFORCING STEEL." 5. CBC CHAPTER 19-CONCRETE 6. ACI 318-19 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE." 7. ACI 117-10 "SPECIFICATIONS FOR TOLERANCES FOR CONCRETE CONSTRUCTION AND MATERIALS." SUBMITTALS: CONFORM TO ACI 301 SECTION 3.1.1 "SUBMITTALS, DATA, AND DRAWINGS." SUBMIT PLACING DRAWINGS SHOWING FABRICATION DIMENSIONS AND LOCATIONS FOR PLACEMENT OF REINFORCEMENT AND REINFORCEMENT SUPPORTS. MATERIALS: REINFORCING BARS...................................................ASTM A615, GRADE 60, DEFORMED BARS. WELDABLE REINFORCING BARS..............................ASTM A706, GRADE 60, DEFORMED BARS. SMOOTH WELDED WIRE FABRIC..............................ASTM A185 DEFORMED WELDED WIRE FABRIC..........................ASTM A497 BAR SUPPORTS............................................................CRSI MSP-09, CHAPTER 3 "BAR SUPPORTS." TIE WIRE.......................................................................16 GAGE OR HEAVIER, BLACK ANNEALED. STUD RAILS...................................................................ASTM A1044 HEADED DEFORMED BARS.........................................ASTM A970 EARTHQUAKE REQUIREMENTS: LONGITUDINAL BARS IN SHEAR WALLS SHALL CONFORM TO ASTM A706, GRADE 60 OR SHALL CONFORM TO THE FOLLOWING: 1.WELDING: WELDING IS NOT PERMITTE EXCEPT AS SPECIFIED IN THE DRAWINGS. WELD IN ACCORDANCE WITH AWS D1.4 2.MILL TESTS: SUBMIT MILL CERTIFICATES INDICATING PHYSICAL AND CHEMICAL PROPERTIES. 3.YIELD STRENGTH: ACTUAL YIELD STRENGTH, BASED ON MILL TESTS, DOES NOT EXCEED THE SPECIFIED YIELD STRENGTH BY MORE THAN 18,000 PSI. (RETESTS SHALL NOT EXCEED THIS 4. VALUE BY MORE THAN AN ADDITIONAL 3000 PSI.) FABRICATION: CONFORM TO ACI 301, SECTION 3.2.2. "FABRICATION", AND ACI SP66 "ACI DETAILING MANUAL. CONCRETE COVER: CONFORM TO THE FOLLOWING REQUIREMENTS UNLESS NOTED OTHERWISE IN THE DRAWINGS. CONCRETE CAST AGAINST EARTH……………………….....3” CONCRETE EXPOSED TO EARTH OR WEATHER………….2” TIES IN COLUMNS AND BEAMS……………………………….1-1/2 “ BARS IN SLABS……………………………………………….......1” BARS IN WALLS……………………………………….................3/4” SPLICES: CONFIRM TO ACI 301, SECTION 3.3.2.7, “SPLICES”. REFER TO “TYPICAL LAP SPLICE AND DEVELOPMENT LENGTH SCHEDULE” FOR TYPICAL REINFORCEMENTS SPLICES. REFER TO “COLUMN VERTICAL REINFORCING SPLICE SCHEDULE” FOR THOSE SPECIFIC ELEMENTS. SPLICES INDICATED ON INDIVIDUAL SHEETS SHALL CONTROL OVER THE SCHEDULE. MECHANICAL CONNECTIONS MAY BE USED WHEN APPROVED BY THE SER. FOR REINFORCING WITHIN THE LATERAL SYSTEM (SHEAR WALLS) AND REINFORCING CONNECTING DIAPHRAGM SLAB TO THE LATERAL SYSTEM, MECHANICAL SPLICE STRENGTH IS INCREASED TO DEVELOP 100 PERCENT OF THE SPECIFIED TENSILE STRENGTH OF THE SPLICES BAR. STUDRAILS: WHERE STUDRAILS ARE INDICATED ON THE DRAWINGS THE FOLLOWING SYSTEMS ARE ACCEPTABLE. STUDRAILS (ALSO REFERRED TO AS PUNCHING SHEAR RESISTOR RAILS) SHALL CONFORM TO ASTM A1044 AND BE FABRICATED AND INSTALLED IN STRICT ACCORDANCE WITH THE APPLICABLE ICC-ESR REPORT AND MANUFACTURER'S INSTRUCTIONS, USING CHAIR PROVIDED BY THE MANUFACTURER TO POSITION RAILS AT THE PROPER HEIGHT. SUBMIT CURRENT MANUFACTURER'S DATA AND ICC ESR REPORT OF ALTERNATE SYSTEMS TO SER FOR APPROVAL. 1. DECON “STUDRAILS” - ICC ESR-2494 2. SIMPSON STRONG-TIE “PUNCHING SHEAR RESISTOR RAILS (PSRR) - ICC ESR-2992] FIELD BENDING: CONFORM TO ACI 301 SECTION 3.3.2.8 “FIELD BENDING OR STRAIGHTENING.” BAR SIZES #3 THROUGH #5 MAY BE FIELD BENT COLD FOR THE FIRST TIME. OTHER BARS REQUIRE PREHEATING. DO NOT TWIST BARS. BARS SHALL NOT BE BENT PAST 45 DEGREES. SHOTCRETE REFERENCE STANDARDS: CONFORM TO: 1. CBC SECTION 1910 “SHOTCRETE”, 2. ACI 506.2-95 “SPECIFICATION FOR SHOTCRETE”' 3. ACI 506R-05 “GUIDE TO SHOTCRETE”, 4. ACI 301-10 “SPECIFICATIONS FOR STRUCTURAL CONCRETE.” SUBMITTALS: SUBMIT SHOP DRAWINGS FOR REVIEW INCLUDING: 1. PROPOSED MIX DESIGN SHOWN BELOW. INCLUDE DATA REQUIRED BY ACI 506.2 SEC. 1.5 “SUBMITTALS” 2. PRECONSTRUCTION TEST PANEL RESULTS. AFTER SHOOTING, THE SPECIAL INSPECTOR SHALL SUBMIT CORE EVALUATION REPORTS TO INSURE THAT PROPER REBAR ENCASEMENT AND NUZZLING TECHNIQUES HAVE BEEN ACHIEVED. 3. CONSTRUCTION TEST SPECIMEN RESULTS. SPECIAL INSPECTOR SHALL SUBMIT CORE STRENGTH REPORTS. MATERIALS: CONFORM ACI 506.2 SEC. 2 “MATERIALS” FOR CEMENTS, AGGREGATE, REINFORCEMENT , WATER, ADMIXTURES AND CURING MATERIALS REINFORCEMENT: CONFORM TO CBC SEC. 1910.4 “REINFORCEMENT” AND CONCRETE REINFORCEMENT SECTION THIS SHEET. SPLICES: CONFORM TO CBC SEC. 1910.4.3, “SPLICES”, FOR NON-CONTANT LAP SPLICES PRECONSTRUCTION TESTS: PREPARE PRECONSTRUCTION TEST PANELS, AS DEFINED BY THE SER, FOR EACH PROPOSED MIX DESIGN AND NOZZELMAN IN ACCORDANCE WITH CBC SEC 1910.5 “PRECONSTRUCTION TESTS” AND ACI 506.3 SEC 2.6.2 “PRECONSTRUCTION TESTING”. TEST PANELS WILL BE CORED ARE MOST CONGESTED REINFORCING AND EVALUATED BY THE TESTING LABORATORY. EACH NOZZELMAN MUST PASS THE EVALUATION BEFORE PROCEEDING WITH THE WORK. CONSTRUCTION TESTS: CONFORM TO CBC SEC 1910.10 “STRENGTH TESTS” AND ACI 506.2 SEC 1.6.2 “CONSTRUCTION TESTING”. TAKE CORE SPECIMENS FOR EACH 50 CU YDS PLACED BUT NOT LESS THAN ONCE EACH SHIFT. THE CORES MAY BE TAKEN FROM THE ACTUAL CONSTRUCTION WORK OR SAMPLE PANELS SHOT DURING THE COURSE OF WORK. LOCATION OF CORES TAKEN FROM ACTUAL CONSTRUCTION WORK MUST BE APPROVED BY THE SER PRIOR TO COMMENCING WORK. SAMPLE PANELS SHALL BE AT LEAST 12”X12”X7-1/4”. THREE CORES SHALL BE TAKEN FROM EACH SAMPLE PANEL AND THE CORES MAY EITHER FIELD CURED OR LABORATORY CURED. LABORATORY CURED SAMPLES HAVE AN AVERAGE STRENGTH EQUAL TO OR GREATER THAN F'C WITH NO INDIVIDUAL SAMPLE BREAKING AT LESS THAN 0.75 F'C. FIELD SURED SAMPLES SHOULD HAVE AN AVERAGE STRENGTH OF AT LEAST 85 F'C WITH NO INDIVIDUAL SAMPLES BREAKING AT LESS THAN 0.75 F'C. CONSTRUCTION: CONFORMS TO CBC SEC 1910 AND ACI 506.2 SEC 3 “EXECUTION” FOR EXAMINATION, BATCHING AND MIXING, SURFACE PREPARATION, JOINTS, ALIGNMENT CONTROL, APPLICATION, FINISHING, HOT WEATHER, COLD WEATHER, PROTECTION, CURING, AND TOLERANCES. THE CONTRACTOR SHALL ADHERE TO THE FOLLOWING WEATHER RELATED PRECAUTIONS. REINFORCED UNIT MASONRY REFERENCE STANDARDS: CONFORM TO: 1. CBC CHAPTER 21 “MASONRY.” 2.ACI 530-11/ASCE 5-11/TMS 402-11 “BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES.” HEREIN REFERENCED AS MSJC. 3. ACI 530.1-11/ASCE 6-11/TMS 602-11 “SPECIFICATION FOR MASONRY STRUCTURES.” HEREIN REFERENCED AS MSJC.1. 4. ACI SP-66 “ACI DETAILING MANUAL” INCLUDING ACI 315 “DETAILS AND DETAILING OF CONCRETE REINFORCEMENT.” 5. ANSI/AWS D1.4 “STRUCTURAL WELDING CODE- REINFORCING STEEL.” SUBMITTALS: CONFORM TO MSJC.1 SECTION 1.2. SUBMIT SHOP DRAWINGS FOR REVIEW INCLUDING: 1. MASONRY REINFORCEMENT, SIZE, LAYOUT, AND GRADE IN ACCORDANCE WITH PLANS. 2. MATERIAL CERTIFICATES FOR ALL STEEL REINFORCING, ANCHORS, TIES AND METAL ACCESSORIES CERTIFYING COMPLIANCE WITH REQUIRED STRENGTH, GRADE AND ASTM STANDARDS. 3. CERTIFICATION LETTERS FOR MASONRY BLOCK AND GROUT MIX DESIGNS CERTIFYING COMPLIANCE WITH REQUIRED STRENGTH AND RESPECTIVE ASTM STANDARDS \ 4. MIX DESIGNS FOR EACH GROUT MIX INDICATING TYPE AND PROPORTIONS OF INGREDIENTS IN COMPLIANCE PROPORTION SPECIFICATION. 5. LOCATION OF EXPANSION AND CONTROL JOINTS. 6. PRODUCT INFORMATION, ICC ESR REPORTS AND MATERIAL CERTIFICATIONS CERTIFYING COMPLIANCE FOR ALL NON-PRE-APPROVED POST-INSTALLED ANCHORS. 7. HOT AND/OR COLD WEATHER CONDUCTION PROCEDURES. 8. HIGH GROUT LIFT PROCEDURES. STRENGTH: THE ASSUMED COMPRESSIVE STRENGTH OF MASONRY ASSEMBLAGE, F'M, IS 1500 PSI BASED ON CBC SECTION 2015.2.2.1.2 FOR CONCRETE MASONRY. MATERIALS: 1.CONCRETE MASONRY UNITS: CONFORM TO ASTM C 90, TYPE-I (MOISTURE CONTROLLED), MEDIUM WEIGHT (APPROX. 115 PCF) UNITS. PROVIDE 1900 PSI COMPRESSIVE STRENGTH TO ACHIEVE MASONRY ASSEMBLY STRENGTH INDICATED ABOVE UNDER STRENGTH 2.MORTAR: CONFORM TO ASTM C270, TYPE S, AND CBC SECTION 2103.9 “MORTAR.” 3.GROUT: CONFORM TO ASTM C476 AND CBC SECTION 2103.13 PROPORTION SPECIFICATION. 4.REINFORCING BARS: CONFORM TO ASTM A615, GRADE 60 DEFORMED BARS AND CBC SECTION 2103.14 UNLESS NOTED OTHERWISE. LAP SPLICES SHALL BE AS NOTED ON PLANS. FABRICATION SHALL BE IN ACCORDANCE WITH MSJC.1 SECTION 2.7. 5.JOINT REINFORCEMENT: CONFORM TO ASTM A951 AND CBC SECTION 2103.14. 6.ANCHORS, TIES AND ACCESSORIES: CONFORM TO CBC SECTION 2103.14 AND MSJC.1 SECTION 2.4D. 7.WATER: SHALL BE CLEAN AND POTABLE 8.ADMIXTURES: ADMIXTURES SHALL NOT BE USED UNLESS APPROVED BY SER. 9.POST-INSTALLED ANCHORS IN MASONRY: REFERENCE THE POST-INNSTALLED ANCHORS SECTION FOR APPLICABLE POST-INSTALLED ANCHORS IN MASONRY. 10.SECOND-HAND UNITS: SHALL NOT BE USED UNLESS APPROVED BY EOR QUALITY ASSURANCE: CONFORM TO CBC SECTION 2105 “QUALITY ASSURANCE” 1.MASONRY UNITS: A LETTER OF CERTIFICATION FROM THE MANUFACTURER OF THE UNITS SHALL BE PROVIDED TO THE SER PRIOR TO THE DELIVERY OF THE UNITS TO THE JOBSITE TO ENSURE THE UNITS COMPLY WITH THE COMPRESSIVE STRENGTH SPECIFIED ABOVE AND ASTM C 90. 2.MORTAR: NO MORTAR TESTING IS REQUIRED. 3.GROUT: A LETTER OF CERTIFICATION FROM THE SUPPLIER OF THE GROUT SHALL BE PROVIDED TO THE EOR PRIOR TO DELIVERY OF THE GROUT TO THE JOBSITE TO ENSURE THAT THE GROUT COMPLIES WITH ASTM C 476. DELIVERY, STORAGE AND HANDLING: DELIVERY, STORAGE AND HANDLING OF MATERIALS USED FOR MASONRY CONSTRUCTION SHALL BE PER MSJC.1, SECTION 1.7. SPECIAL INSPECTION: SPECIAL INSPECTIONS SHALL BE PERFORMED PER THE “TESTS AND INSPECTIONS” SECTION OF THE STRUCTURAL GENERAL NOTES ANCHORS, TIES AND CONNECTORS: MASONRY ANCHORS, TIES AND CONNECTORS SHALL BE A SPECIFIED ON STRUCTURAL DRAWINGS. CONSULT ARCHITECTURAL DRAWINGS FOR MASONRY ANCHOR TIES NOT INCLUDED ON THE STRUCTURAL DRAWINGS. EMBEDDED ITEMS: EMBEDDED ITEMS AND ACCESSORIES SHALL BE IN ACCORDANCE WITH MSJC SECTION 1.15 AND INSTALLED IN ACCORDANCE WITH MSJC.1 SECTION 3.3D. POSITION AND SECURE IN PLACE EXPANSION JOINT MATERIAL, ANCHORS AND OTHER STRUCTURAL AND NON-STRUCTURAL EMBEDDED ITEMS BEFORE PLACING GROUT. CONTRACTOR SHALL REFER TO STRUCTURAL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, ETC. AND COORDINATE ALL EMBEDDED ITEMS. POST-INSTALLED ANCHORS TO MASONRY: ANCHOR LOCATIONS, TYPE, DIAMETER AND EMBEDMENT SHALL BE AS INDICATED ON DRAWINGS. REFERENCE THE POST INSTALLED ANCHORS SECTION FOR APPLICABLE POST-INSTALLED ANCHOR ADHESIVES. ANCHORS SHALL BE INSTALLED AND INSPECTED IN STRICT ACCORDANCE WITH THE APPLICABLE ICC-EVALUATION SERVICE REPORT (ESR). SPECIAL INSPECTION SHALL BE PER THE TEST AND INSPECTIONS SECTION. MASONRY REINFORCING STEEL: MASONRY REINFORCING SHALL BE AS NOTED ON PLANS AND SHALL BE SECURELY PLACED IN ACCORDANCE WITH CBC SECTIONS 2104.1.1, 2106, AND 2108 AND MSJC SECTION 1.16. UNLESS OTHERWISE NOTED ON THE PLANS, THE MINIMUM WALL REINFORCEMENT SHALL BE AS FOLLOWS: BOND BEAMS WITH HORIZONTAL BAR OR BARS SHALL BE PROVIDED AT 48 INCHES ON CENTER MINIMUM AND AT ALL FLOOR AND ROOF LINES AND AT THE TOP OF THE WALL. PROVIDE A BOND BEAM WITH HORIZONTAL BAR OR BARS OVER ALL OPENINGS, AND EXTEND THESE BARS 2'-0” PAST THE OPENING AT EACH SIDE. PROVIDE A BAR OR BARS VERTICALLY FOR THE FULL HEIGHT OF THE WALL AT EACH SIDE OF OPENINGS, WALL ENDS AND INTERSECTIONS. DOWELS TO MASONRY WALLS SHALL BE EMBEDDED A MINIMUM OF 1'-6” OR HOOKED INTO SUPPORTING STRUCTURE AND BE OF THE SAME SIZE AND SPACING AS WALL REINFORCING. REINFORCING STEEL SHALL BE AS SPECIFIED UNDER “MATERIALS” SECTION. PROVIDE CORNER BARS TO MATCH THE HORIZONTAL WALL REINFORCING AT ALL WALL INTERSECTIONS. ALL BARS SHALL BE LAPPED A MINIMUM 48 DIAMETERS OR 1'-6” MINIMUM UNLESS NOTED ON THE PLANS. LINTELS: REINFORCED MASONRY LINTELS TO BE INSTALLED OVER ALL OPENINGS UNLESS OTHERWISE INDICATED ON DRAWINGS. DO NOT SPLICE REINFORCING BARS WITHIN LINTELS AND MAINTAIN 8 INCH BEARING MINIMUM ON EACH SIDE. UNLESS OTHERWISE NOTED ON THE PLANS, THE MINIMUM REINFORCEMENT FOR LINTELS IN 8” MASONRY SHALL BE AS FOLLOWS: 1.OPENINGS UP TO 42 INCHES WIDE: (2) #4 AT THE BOTTOM WEB OF 8 INCH DEEP LINTEL 2.OPENINGS 42 TO 78 INCHES WIDE: (2) #4 AT BOTTOM WEB OF 16 INCH DEEP LINTEL 3.OPENINGS OVER 78 INCHES WIDE: REINFORCE PER DRAWINGS CONSTRUCTION: MASONRY SHALL BE CONSTRUCTED IN ACCORDANCE WITH CBC SECTION 2104 “CONSTRUCTION”, AND MSJC.1 PART 3 “EXECUTION.” COLD AND HOT WEATHER CONSTRUCTION: COLD AND HOT WEATHER CONSTRUCTION SHALL BE IN ACCORDANCE WITH SECTION 2104.3 AND 2104.4. BLOCK PATTERN: USE RUNNING BOND UNLESS NOTED. FOR STACK BOND, FOLLOW CRITERIA IN MSJC SECTION 1.11. GROUTED CELLS: FILL ALL CELLS WITH GROUT UNLESS NOTED OTHERWISE N PLANS. MINIMUM GROUTING SPACES AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH MSJC SECTION 1.16 AND MSJC SECTION 3.5. GROUT POUR HEIGHT; GROUT POUR HEIGHT SHALL NOT EXCEED HEIGHT SPECIFIED IN MSJC.1 SECTION 3.5C. ·MASONRY BOCKS SHALL BE ADEQUATELY BRACED TO WITHSTAND FLUID PRESSURES OR GROUT POUR, SEE TEMPORARY BRACING. GROUT LIFTS: UNLESS OTHERWISE NOTES, GROUT LIFTS AND POUR HEIGHT SHALL NOT EXCEED 5FT 4IN. GROUT LIFTS SHALL NOT EXCEED SPACING OF INTERMEDIATE REINFORCED BOND BEAMS. GROUT LIFTS EXCEEDING 5FT 4IN SHALL BE APPROVED BY SER. REINFORCING COVER AND CLEARANCE REQUIREMENTS: UNLESS OTHERWISE NOTED: CLEAR DISTANCE BETWEEN PARALLEL BARS (AND BETWEEN ADJACENT PAIRS OF LAP SPLICED BARS) SHALL BE EQUAL TO THE BAR ADJACENT BAR DIAMETER (FOR BARS GREATER THAN #8), AND NOT LESS THAN: 1. 1” AT 8” AND SMALLER BLOCK, 2. 2” AT 10” BLOCK 3. 3” AT 12” BLOCK CLEARANCE (CLEAR SPACE) BETWEEN THE BLOCK AND REINFORCING SHALL BE: 1. ¼” AT FINE GROUT 2. ½” AT COURSE GROUT MASONRY COVER (INCLUDING GROUT AND BLOCK WALL) AT MASONRY FACE EXPOSED TO EARTH OR WEATHER SHALL BE: 1. 1 ½” MINIMUM 2. 2” FOR BARS #6 AND LARGER CONTROL AND EXPANSION JOINTS: REFERENCE DRAWINGS FOR TYPICAL DETAILS OF MASONRY CONTROL AND EXPANSION JOINTS. LOCATION OF CONTROL AND EXPANSIONS JOINTS SHALL BE APPROVED BY SER. UNLESS OTHERWISE INDICATED ON DRAWINGS, INSTALL CONTROL AND EXPANSION JOINTS AT THE FOLLOWING: 1.CONTINUOUS WALLS: VERTICAL JOINTS AT THE LESSER OF 1.5 TIMES THE WALL HEIGHT OR 25 FEET ON CENTER MAXIMUM. 2.CORNERS AND INTERSECTING WALLS: FIRST VERTICAL JOINT FROM THE CORNER AT LESSER OF 1.2 TIMES THE WALL HEIGHT OR 16 FEET. 3.ABRUPT CHANGES IN WALL HEIGHT AND WALL THICKNESS, SUCH AS ADJACENT TO COLUMNS OR PILASTERS. TEMPORARY BRACING: CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY BRACING OF MASONRY DURING CONSTRUCTION. REFERENCE “CONTRACTOR RESPONSIBILITIES” SECTION FOR FURTHER INFORMATION AND REQUIREMENTS. POST-INSTALLED ANCHORS (INTO CONCRETE AND MASONRY) REFERENCE STANDARDS: CONFORM TO: 1. CBC CHAPTER 19 “CONCRETE” 2. ACI 318-11 “BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE” 3. CBC CHAPTER 21 “MASONRY” 4. ACI 530-11/ASCE 5-11/TMS402-11 “BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES” POST-INSTALLED ANCHORS: INSTALL ONLY WHERE SPECIFICALLY SHOWN IN DETAILS AND PLANS OR ALLOWED BY EOR. ALL POST-INSTALLED ANCHORS TYPES AND LOCATIONS SHALL BE APPROVED BY THE EOR AND SHALL HAVE A CURRENT ICC-EVALUATIONS SERVICE REPORT THAT PROVIDES RELEVANT DESIGNS VALUES NECESSARY TO VALIDATE THE AVAILABLE STRENGTH EXCEEDS THE REQUIRED STRENGTH. ANCHORS SHALL BE INSTALLED IN STRICT ACCORDANCE TO ICC-ESR AND MANUFACTURER'S INSTRUCTIONS. NO REINFORCING BARS SHALL BE DAMAGED DURING INSTALLATION OF POST-INSTALLED ANCHORS. SPECIAL INSPECTION SHALL BE PER THE TESTS AND INSPECTIONS SECTION. ANCHOR TYPE, DIAMETER AND EMBEDMENT SHALL BE AS INDICATED ON DRAWINGS. 1.ADHESIVE ANCHORS: THE FOLLOWING ADHESIVE-TYPE ANCHORING SYSTEMS HAVE BEEN USED IN THE DESIGN AND SHALL BE USED FOR ANCHORAGE TO CONCRETE AND MASONRY, AS APPLICABLE AND IN ACCORDANCE WITH CORRESPONDING CURRENT ICC ESR REPORT. DRILLED-IN ANCHOR EMBEDMENT LENGTHS SHALL BE AS SHOWN ON DRAWINGS, OR NOT LESS THAN 7 TIMES THE ANCHOR NOMINAL DIAMETER (7D). a. HILTI “HIT-HY 200” - ICC ESR- 3187 FOR ANCHORAGE TO CONCRETE WITH MIN EMBEDMENT DEPTH OF 20 BAR DIAMETERS b. HILTI “HIT-HY 500 SD”- ICC ESR 2322 FOR CONCRETE ONLY c. SIMPSON “SET-XP”- ICC ESR 2508 FOR ANCHORAGE TO CONCRETE IAPMO 265 FOR ANCHORAGE TO MASONRY d. POWERS “PE1000”-ICC ESR 2583 FOR ANCHORAGE TO CONCRETE e. HILTI “HY-150 MAX”-ICC ESR-1967- FOR ANCHORAGE TO MASONRY ONLY 2.EXPANSION ANCHORS: THE FOLLOWING EXPANSION TYPE ANCHORS ARE PRE-APPROVED FOR ANCHORAGE TO CONCRETE OR MASONRY IN ACCORDANCE WITH CORRESPONDING CURRENT ICC ESR REPORT: a. HILTI “KWIK BOLT TZ”- ICC ESR-1917 FOR CONCRETE ONLY b. SIMPSON “STORNG-BOLT 2” - ICC ESR-3037 FOR CONCRETE ONLY c. POWERS “POWER-STUD+SD1”- ICC ESR-28181 FOR CONCRETE ONLY AND ICC ESR-2966 FOR MASONRY ONLY d. HILTI “KWIK BOLT 3- ICC ESR-1385 FOR ANCHORAGE TO MASONRY ONLY e. SIMPSON “WEDGE-ALL” ICC ESR-1396 FOR ANCHORAGE TO MASONRY ONLY 3.SCREW ANCHORS: THE FOLLOWING SCREW TYPE ANCHOR IS PRE-APPROVED FOR ANCHORAGE TO CONCRETE OR MASONRY IN ACCORDANCE WITH CORRESPONDING CURRENT ICC ESR REPORT: a. SIMPSON “TITAN HD”-ICC ESR-2713 FOR CONCRETE ONLY AND ICC ESR-1056 FOR MASONRY ONLY b. POWERS “WEDGE-BOLT +” - ICC ESR 2526 FOR CONCRETE ONLY AND ICC ESR 1678 FOR MASONRY ONLY c. POWERS “SNAKE”-ICC ESR 2272 FOR ANCHORAGE TO CONCRETE ONLY d. HILTI “HUS-EZ” - ICC ESR 3027 FOR ANCHORAGE TO CONCRETE ONLY AND ICC ESR-3056 FOR MASONRY ONLY28 28 28 28 28 28 28 28 3/4" 1" 3/4" 1" 1" 1" 0.40 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.45 S-0.11 ST R U C T U R A L N O T E S DATE:11/14/2024 JOB NO: MLB24-1210 DESIGNED BY: HK CHECKED BY: GB DE S C R I P T I O N DA T E RE V BY 1 3 4 5 - 2 - - MLB CONSULTING AND ENGINEERING, INC 7918 FOOTHILL BLVD SUNLAND, CA 91040 (818) 521-6342 INFO@MLBENGINEERING.ORG 4703 W McFadden Ave Santa Ana, CA 92704 DATE:11/14/2024 JOB NO: MLB24-1210 DESIGNED BY: HK CHECKED BY: GB DE S C R I P T I O N DA T E RE V BY 1 3 4 5 - 2 - - MLB CONSULTING AND ENGINEERING, INC 7918 FOOTHILL BLVD SUNLAND, CA 91040 (818) 521-6342 INFO@MLBENGINEERING.ORG 4703 W McFadden Ave Santa Ana, CA 92704 STRUCTURAL STEEL REFERENCE STANDADS: CONFORM TO: 1. CBC CHAPTER 22- “STEEL” 2. NASI/AISC 303-10- “CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS & BRIDGES” 3. ANSI/AISC 325-10- “STEEL CONSTRUCTION MANUAL” 4. ANSI/AISC 360-10- “SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS” 5. AWS D1.1:2010- “STRUCTURAL WELDING CODE-STEEL” 6. 2009 RCSC- “SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH-STRENGTH BOLTS” 7. ANSI/AISC 341-10- “SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS” 8. AWS D1.8:2009- “STRUCTURAL WELDING CODE- SEISMIC SUPPLEMENT” SPECIAL PROVISIONS FOR ELEMENTS OF THE SEISMIC FORCE RESISTING SYSTEM (SFRS): SELECTED STEEL ELEMENTS OF THIS PROJECT ARE PART OF THE SEISMIC FORCE RESISTING SYSTEM” (SFRS) AND, THUS ARE SUBJECT TO SPECIAL REQUIREMENTS DETAILED IN THE AISC “SEISMIC PROVISIONS”. ELEMENTS OF THE SFRS DESIGNATED ON PLANS. REFER TO DRAWING LEGEND FOR SYMBOLS USED TO DESIGNATE ELEMENTS ON THE PLANS AND STRUCTURAL STEEL SEISMIC PROVISIONS SECTION OF GENERAL NOTES FOR SUPPLEMENTAL REQUIREMENTS. SUBMITTALS: SUBMIT THE FOLLOWING DOCUMENTS TO THE SER FOR REVIEW: 1.SHOP DRAWINGS COMPLYING WITH AISC 360 SECTIONS M1 AND N3 AND AISC 303 SECTION 4. 2.ERECTION DRAWINGS COMPLYING AISC 360 SECTION M1 AND N3 AND AISC 303 SECTION 4 3.WELD PROCEDURE SPECIFICATION (WPS'S) FOR SHOP AND FIELD WELDING. 4.MANUFACTURER'S CERTIFICATES OF CONFORMANCE FOR ELECTRODES, FLUXES AND GASES (WELDING CONSUMABLES). MAKE COPIES OF THE FOLLOWING DOCUMENTS “AVAILABLE UPON REQUEST” TO THE SER OR OWNER'S INSPECTION AGENCY IN ELECTRONIC OR PRINTED FORM PRIOR TO FABRICATION PER AISC 360 SECTION N3.2 REQUIREMENTS: 1.FABRICATOR'S WRITTEN QUALITY CONTROL MANUAL THAT INCLUDES, AS A MINIMUM: 1.a. MATERIAL CONTROL PROCEDURES 1.b. INSPECTION PROCEDURES 1.c. NON-CONFORMANCE PROCEDURES 2.STEEL & ANCHOR ROD SUPPLIERS' MATERIAL TEST REPORTS (MTR'S) INDICATING THE COMPLIANCE WITH SPECIFICATIONS. 3.FASTENER MANUFACTURER'S CERTIFICATION DOCUMENTING CONFORMANCE WITH THE SPECIFICATION. 4.FILLER METAL MANUFACTURER'S PRODUCT DATA FOR SMAW, FCAW AND GMAW INDICATING: 4.a. PRODUCT SPECIFICATION COMPLIANCE 4.b. RECOMMENDED WELDING PARAMETERS 4.c. RECOMMENDED STORAGE AND EXPOSURE REQUIREMENTS INCLUDING BAKING 4.d. LIMITATIONS OF USE 5.WELDED HEADED (SHEAR) STUD ANCHORS MANUFACTURER'S CERTIFICATIONS INDICATING AND MEET SPECIFICATIONS. 6.PROCEDURE QUALIFICATION RECORDS (PQP'S FOR WPS'S THAT ARE NOT PREQUALIFIED IN ACCORDANCE WITH AWS. 7.WELDING PERSONNEL PERFORMANCE QUALIFICATION RECORDS (WPQP) AND CONTINUITY RECORDS CONFORMING TO AWS STANDARDS. MATERIALS: STRUCTURAL STEEL MATERIALS SHALL CONFORM TO MATERIALS AND REQUIREMENTS LISTED IN AISC 360 SECTION A3 INCLUDING, BUT NOT LIMITED TO: STRUCTURAL JOINTS USING HIGH-STRENGTH BOLT: 1. ASTM A325-N BOLTS- “THREADS NOT EXCLUDED IN THE SHEAR PLANE.” 2. HIGH-STRENGTH BOLTED JOINTS HAVE BEEN DESIGNED AS 'BEARING” CONNECTIONS. 3. PROVIDE ASTM BOLT GRADE AND TYPE AS SPECIFIED IN THE MATERIALS SECTION ABOVE. 4. PROVIDE WASHERS OVER OUTER PLY OF SLOTTED HOLES AND OVERSIZE HOLES PER RCSC TABLE 6.1. 5. PROVIDE NUT AND WASHERS GRADES, TYPES AND FINISHES CONFORMING TO RCSC SPECIFICATION TABLE 2.1. 6. PROVIDE FASTENER ASSEMBLIES FROM A SINGLE SUPPLIER. 7. JOINT TYPES SHALL BE: 8. ST - “SNUG TIGHT FOR TYPICAL BEAM END “SHEAR” CONNECTIONS, UNLESS NOTED OTHERWISE. 9. SC - “SLIP CRITICAL”, WHERE SPECIFICALLY INDICATED. PROVIDE WITH CLASS A FAYING SURFACE. 10. INSTALL BOLTS IN JOINTS IN ACCORDANCE WITH THE RCSC SPECIFICATION SECTION 8 AND TABLE 4.1 11. INSPECTION IS PER RCSC SECTION 9. ANCHORAGE TO CONCRETE: 1.EMBEDDED STEEL PLATES FOR ANCHORAGE TO CONCRETE: PLATES (PL) EMBEDDED IN CONCRETE WITH STUDS (WHS) OR DOWEL BAR ANCHORS (DBA) SHALL BE OF THE SIZES AND LENGTHS AS INDICATED ON THE PLANS WITH MINIMUM ½” DIA. WHS X 6” LONG BUT PROVIDE NOT LESS THAN ¾” INTERIOR COVER OR 1 ½” EXTERIOR COVER TO THE OPPOSITE FACE OF CONCRETE, UNLESS NOTED OTHERWISE. 2.COLUMN ANCHOR RODS AND BASE PLATES: ALL COLUMNS (VERTICAL MEMBER ASSEMBLIES WEIGHING OVER 300 POUNDS) SHALL BE PROVIDED WITH A MINIMUM OF FOUR ¾” DIAMETER ANCHOR RODS. COLUMN BASE PLATES SHALL BE AT LEAST ¾” THICK, UNLESS NOTED OTHERWISE. CAST-IN-PLACE ANCHOR RODS SHALL BE PROVIDED UNLESS OTHERWISE APPROVED BY THE ENGINEER. UNLESS NOTED OTHERWISE, EMBEDMENT OF CAST-IN-PLACE ANCHOR RODS SHALL BE 12 TIMES THE ANCHOR DIAMETER (12D) FABRICATION: 1. CONFORM TO AISC 360 SECTION M2 “FABRICATION” AND AISC 303 SECTION 6 “SHOP FABRICATION” 2. QUALITY CONTROL (QC) SHALL CONFORM TO: a. AISC 360 CHAPTER N “QUALITY CONTROL AND QUALITY ASSURANCE” AND b. AISC 303 SECTION 8 “QUALITY CONTROL”. c. FABRICATOR AND ERECTOR SHALL ESTABLISH AND MAINTAIN WRITTEN QUALITY CONTROL (QC) PROCEDURES PER AISC 360 SECTION N3. d. FABRICATOR SHALL PREFORM SELF-INSPECTIONS PER AISC 360 SECTION N5 TO ENSURE THAT THEIR WORK IS PERFORMED IN ACCORDANCE WITH CODE OF STANDARD PRACTICE, THE AISC SPECIFICATION, CONTRACT DOCUMENTS AND THE APPLICABLE BUILDING CODE. e. QC INSPECTIONS MAY BE COORDINATED WITH QUALITY ASSURANCE INSPECTIONS PER SECTION N5.3 WHERE FABRICATORS QA PROCEDURES PROVIDE THE NECESSARY BASIS FOR MATERIAL CONTROL, INSPECTION, AND CONTROL OF THE WORKMANSHIP EXPECTED BY THE SPECIAL INSPECTOR WELDING: 1. WELDING SHALL CONFORM TO AWS D1.1 AND D1.8 AS APPLICABLE FOR SEISMIC ELEMENTS WITH PREQUALIFIED WELDING PROCESSES EXCEPT MODIFIED BY AISC 360 SECTION J2 AND AISC 341 AS APPLICABLE. WELDERS SHALL BE QUALIFIED IN ACCORDANCE WITH AWS D1.1 (AND D1.8 FOR DEMAND CRITICAL WELDS WHERE APPLICABLE) REQUIREMENTS 2. USE 70KSI STRENGTH, LOW-HYDROGEN TYPE ELECTRODES (E7018) OR E71T AS APPROPRIATE FOR THE PROCESS SELECTED. 3. WELDING OF HIGH STRENGTH ANCHOR RODS IS PROHIBITED UNLESS APPROVED BY ENGINEER 4. WELDING OF HEADED STUD ANCHORS SHALL BE IN ACCORDANCE WITH AWS D1.1 CHAPTER 7 “STUD WELDING” ERECTION: 1. CONFORM TO AISC 360 SECTION M4 “ERECTION” AND AISC 303 SECTION 7 “ERECTION” 2. CONFORM TO AISC 360 CHAPTER N “QUALITY CONTROL AND QUALITY ASSURANCE” AND AISC 303 SECTION 8 3. THE ERECTOR SHALL MAINTAIN DETAILED ERECTION QUALITY CONTROL PROCEDURES THAT ENSURE THAT THE WORK IS PERFORMED ON ACCORDANCE WITH THESE REQUIREMENTS AND THE CONTRACT DOCUMENTS 4. STEEL WORK SHALL BE CARRIED UP TRUE AND PLUMB WITHIN THE LIMITS DEFINES IN AISC 303 SECTION 7.13. 5. HIGH STRENGTH BOLTING SHALL COMPLY WITH THE RCSC REQUIREMENTS INCLUDING RCSC SECTION 7.2 “REQUIRED TESTING”, AS APPLICABLE AND AISC 360 CHAPTER J, SECTION M2.5 AND SECTION N5.6. 6. WELDING OF HEADED STUD ANCHORS SHALL BE IN ACCORDANCE WITH AWS D1.1 CHAPTER 7 “STUD WELDING. 7. PROVIDE HEADED (SHEAR) STUD ANCHORS WELDED THROUGH METAL DECK TO TOPS OF BEAMS DENOTED IN PLANS 8. THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING AND SAFETY PROTECTION REQUIRED AISC 360 SECTION M4.2 AND AISC 303 SECTION 7.10 AND 7.11. PROTECTIVE COATING REQUIREMENTS 1. SHOP PAINTING: CONFORM TO AISC 360 SECTION M3 AND AISC 303 SECTION 6.5 UNLESS OTHERWISE SPECIFIED BY THE PROJECT SPECIFICATIONS 2. INTERIOR STEEL: a. UNLESS NOTED OTHERWISE, DO NOT PAINT ANY STEEL SURFACES MEETING THE FOLLOWING CONDITIONS: ·CONCEALED BY INTERIOR BUILDING FINISHES, ·FIREPROOFED, ·EMBEDDED IN CONCRETE, ·SPECIALLY PREPARED AS A “FAYING SURFACE” FOR TYPE-SC “SLIP-CRITICAL” CONNECTIONS INCLUDING BOLTED CONNECTIONS THAT FORM A PART OF THE SEISMIC FORCE RESISTING SYSTEM GOVERNED BY AISC 341 UNLESS THE COATING CONFORMS TO REQUIREMENTS OF THE RCSC BOLT SPECIFICATION AND IS APPROVED BY THE ENGINEER. ·WELDED; IF AREA REQUIRES PAINTING, DO NOT PAINT UNTIL AFTER WELD INSPECTIONS AND NON-DESTRUCTIVE TESTING REQUIREMENT, IS ANY, AE SATISFIED b. INTERIOR STEEL, EXPOSED TO VIEW, SHALL BE PAINTED WITH ONE COAT OF THE SHOP PRIMER UNLESS OTHERWISE INDICATED IN THE PROJECT SPECIFICATIONS. FIELD TOUCH-UPS TO MATCH THE FINISH COAT OF AS OTHERWISE INDICATED IN THE PROJECT SPECIFICATIONS. 1.EXTERIOR STEEL: EXPOSED EXTERIOR STEEL SHALL BE PROTECTED BY EITHER: a.PAINT WITH AN EXTERIOR MULTI-COAT SYSTEM AS PER THE PROJECT SPECIFICATIONS. FIELD TOUCH-UP PAINTING SHALL BE AS PER THE PROJECT SPECIFICATIONS. b.GALVANIZING: UNLESS PROTECTED WITH A PAINT SYSTEM, EXPOSED STEEL (OUTSIDE THE BUILDING ENVELOPE) SHALL BE HOT DIPPED GALVANIZED, WHERE NOTED ON PLANS OTHERWISE INDICATED BY THE FINISHES SPECIFIED BY THE ARCHITECT. APPLY FIELD TOUCH-UPS PER PROJECT SPECIFICATIONS. ARCHITECTURALLY EXPOSED STRUCTUAL STEEL: STEEL IDENTIFIED BY ARCHITECT ON THE ARCHITECTURAL DRAWINGS AS ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) SHALL CONFORM AISC 303 SECTION 10 STRUCTURAL STEEL-SEISMIC PROVISIONS REFERENCE STANDARDS: CONFORM TO THE STANDARDS IN THE STRUCTURAL STEEL SECTION AND THE FOLLOWING: 1. ANSI/AISC 341-10 - “SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS” 2. AWS D1.8”2009 - “STRUCTURAL WELDING CODE - SEISMIC SUPPLEMENT” SCOPE: IN ADDITION TO THE STANDARDS SPECIFIED IN THE STRUCTURAL STEEL SECTION OF THESE GENERAL REQUIREMENTS, STRUCTURAL STEEL THAT IS PART OF OR THAT TRANSFERS SEISMIC LOADS TO THE DESIGNATED SEISMIC FORCE RESISTING SYSTEM (SFRS) DEFINED IN THE DESIGN CRITERIA AND LOADS SECTION OF THESE GENERAL REQUIREMENTS, SHALL COMPLY WITH APPLICABLE SEISMIC PROVISIONS BELOW. SEISMIC FORCE RESISTING SYSTEM (SFRS): THE SFRS IS AN ASSEMBLAGE OF BEAMS, COLUMNS, BRACES AND WALLS THAT HAVE BEEN SPECIALLY PROPORTIONED INTO VERTICAL FRAME AND SHEAR WALL] SYSTEMS TO RESIST LATERAL SEISMIC FORCED. BEYOND THE FRAMES AND WALLS ARE TYPICALLY OTHER HORIZONTAL MEMBERS CONNECTING TO THE VERTICAL SHEAR-RESISTING FRAMES AND WALLS THAT “DRAGS”, AND “DIAPHRAGMS” (SUCH AS THE FLOOR SLAB AND ROOF DECK), WHICH ALSO FORM PART OF THE SFRS AND ARE SUBJECT TO THE “SEISMIC PROVISIONS” OF AISC 341. DESIGNATION OF PRIMARY SFRS FRAMING SYSTEM FOR THIS PROJECT IS PROVIDED IN THE DESIGN CRITERIA AND LOADS SECTION OF THESE GENERAL REQIREMENTS. STABILITY OF THE STRUCTURE UNDER SEISMIC LOADS IS RELIANT UPON STRUCTURAL STEEL COLLECTORS, DRAG AND DIAPHRAGM CHORDS WHICH ARE GOVERNED BY THE SEISMIC PROVISIONS. LOWEST ANTICIPATED SERVICE TEMPERATURE (LAST): THE PRIMARY SFRS FRAMING FOR THIS PROJECT IS TO BE ENCLOSED AND EXPECTED TO B MAINTAINED WITH THE LAST OF 50 DEGREES FAHRENHEIT. STRUCTURAL MEMBERS AND THEIR CONNECTIONS CONSIDERED IN THE DESIGN OF THE SFRS ARE SUBJECT TO THE SPECIAL SEISMIC PROVISIONS OF THIS SECTION. SUBJECT ELEMENTS REQUIRE SPECIAL ATTENTION TO DETAILING, MATERIAL CONTROL, DOCUMENTATION, FABRICATION, INSPECTION, AND PROTECTIONS FROM ALL TRADES. SPECIAL REQUIREMENTS INCLUDE BUT ARE NOT LIMITED TO: 1.IDENTIFICATION OF SFRS MEMBERS AND THEIR CONNECTIONS ON SHOP AND ERECTION DRAWINGS; INCLUDE SPECIAL DETAILING, WELDING AND INSPECTION REQUIREMENTS AND LIMITATIONS ON WHERE OTHER TRADES ARE RESTRICTED FROM ANY ATTACHMENTS. REFER TO AISC 341 SECTION D1.3 PROTECTED ZONES. 2.CONNECTION CONFIGURATIONS DETAILED TO SCALE, INCLUDING THE LAYOUT OF BOLTS, PLATES, WELDS AND ANY SPECIAL ERECTION PROCEDURES AND WELDING SEQUENCE REQUIREMENTS. 3. DEMAND CRITICAL WELDS (DCW) SHALL BE NOTED ON SHOP AND ERECTION DRAWINGS. 4. MEMBERS AND PLATES SUBJECT TO CHARPY V-NOTCH (CVN) TOUGHNESS TESTING'S. 5. INDICATE STEEL ELEMENTS WHERE LOWEST ANTICIPATED SERVICE TEMPERATURE, (LAST) IS BELOW 50 DEGREES F. QUALITY CONTROL AND QUALITY ASSURANCE PLAN: QUALITY CONTROL (QC) (BY CONTRACTOR) AND QUALITY ASSURANCE (QA) (BY AN APPROVED SPECIAL INSPECTION AGENCY) FOR MEMBERS OF THE SFRS SHALL BE PROVIDED IN ACCORDANCE WITH AISC 341, CHAPTER J AND COORDINATED PER SECTION J6.4. 1. FABRICATOR AND ERECTOR SHALL HAVE QUALITY CONTROL PROGRAM PER AISC 360 SECTION N2 2. FABRICATOR AND ERECTOR SHALL PROVIDE ACCESS TO THE QUALITY ASSURANCE/SPECIAL INSPECTION AGENCY, PRIOR TO THE START OF WORK, FOR PURPOSES OF REVIEW OF THE QUALITY CONTROL PROGRAM REQUIRED PER AISC 360 SECTION N2 PER CBC 1704.2.5.1 3. SPECIAL INSPECTIONS REQUIRED PER CBC SECTIONS 1705.2.1 AND 1705.11.1 AND THE STATEMENT OF SPECIAL INSPECTIONS SECTION OF THESE GENERAL REQUIREMENTS. SUBMITTALS: 1. SUBMIT FABRICATOR AND ERECTOR DOCUMENTS PER AISC 360 SECTION N3 AND AISC 341 SECTION J2.1. 2. SHOP DRAWINGS OF THE SFRS SHALL BE PREPARED IN ACCORDANCE WITH AISC 303 SECTION 4, AISC 341 3. SECTIONS A4.1, A4.2, AND I1 AND SHALL INCLUDE THE FOLLOWING: 3.·DESIGNATION OF THE SFRS 3.·MEMBER AND CONNECTIONS OF THE SFRS CLEARLY IDENTIFIED 3.·PRE-TENSIONED BOLTS AND FAYING SURFACE PREPARATION LOCATIONS IN SFRS 3.·WELD ACCESS HOLD DIMENSIONS, SURFACE PROFILE AND FINISH REQUIREMENTS 3.·NDT WHERE PERFORMED BY THE FABRICATOR 4. WELD PROCEDURES SPECIFICATIONS (WPS'S) 5. BOLT INSTALLED PROCEDURES 6. CHARPY V-NOTCH CONFORMANCE CERTIFICATION FOR WELDING ELECTRODES, FLUXES AND SHIELDING 7. GASES 8. MATERIAL DATA FOR DEMAND CRITICAL WELDS PER AISC 341 J2.1(3). 9. CHARPY V-NOTCH CONFORMANCE CERTIFICATION/VERIFICATION TEST RESULTS FOR “HEAVY SHAPES” OR 10. JUMBO SECTIONS, IF APPLICABLE. 11. SPECIFIC ASSEMBLY ORDER, WELDING SEQUENCE, WELDING TECHNIQUE, OR OTHER SPECIAL PRECAUTIONS 12. FOR JOINTS OR GROUPS OF JOINTS WHERE SUCH ITEMS ARE DESIGNATED TO BE SUBMITTED TO THE SER. SFRS MATERIALS: STRUCTURAL STEEL PART OF THE SFRS SHALL MEET THE REQUIREMENTS OF AISC 341, SECTION A3.1. REFERENCE THE MATERIALS SECTION OF THE STRUCTURAL STEEL FOR SPECIFIC ASTM SPECIFICATIONS. HEAVY SECTIONS - SPECIAL REQUIREMENTS: IN ADDITION TO AISC 360 A3.1C REQUIREMENTS: HOT-ROLLED SHAPES WITH FLANGES 1 ½ INCH THICK AND THICKER SHALL HAVE A MINIMUM CHARPY V-NOTCH TOUGHNESS OF 20 FT-LBS AT 70 DEGREES F TESTED IN THE ALTERNATE CORE LOCATION AS DESCRIBED IN ASTM A6 SUPPLEMENTARY REQUIREMENT S30 PLATES, 2 INCHES THICK AND THICKER SHALL HAVE A MINIMUM CHARPY V-NOTCH TOUGHNESS OF 20 FT-LBS AT 70 DEGREES F MEASURED AT ANY LOCATION PERMITTED BY ASTM A673, FREQUENCY P, WHERE THE PLATE IS USED FOR: A. CONNECTION PLATES WHERE INELASTIC STRAIN UNDER SEISMIC LOADING IS EXPECTED B. BUILT-UP MEMBERS SFRS BOLTED JOINT REQUIREMENTS: ALL BOLTS SHALL BE INSTALLED AS PRE-TENSIONED HIGH-STRENGTH BOLTS OF SIZE AND ORIENTATIONS AS SHOWN ON THE DRAWINGS. BOLT HOLES SHALL STANDARD HOLES OR SHORT-SLOTTED PERPENDICULAR TO THE APPLIED LOAD UNLESS OTHERWISE NOTED. EXCEPTION: FOR DIAGONAL BRACES IN OCBF, SCBF, OR EBF FRAMES, OVERSIZED HOLES ARE PERMITTED IN ONE CONNECTION PLY PROVIDED BRACE CONNECTION STRENGTH IS BASED ON SLIP-CRITICAL CAPACITIES. ALL BOLTED JOINTS SHALL BE PREPARED WITH CLASS A FAYING SURFACES (OR BETTER) PER RCSC SPECIFICATION SECTION 3.2 AND SHALL HAVE FAYING SURFACES PREPARED AND BOLTS INSTALLED IN ACCORDANCE WITH JOINT TYPE SC - CLASS A (UNCOATED) - “SLIP-CRITICAL” PER RCSC SPECIFICATION TABLE 4.1 AND SECTION 8.2. INSPECTIONS SHALL BE PER RCSC SECTION 9.3 SFRS WELDING REQUIREMNTS: ALL WELDING SHALL BE DONE WITH APPROPRIATE WELD PROCEDURES PREPARED THE SEISMIC SUPPLEMENT, AWD D1.8, INCLUDING, BOTH SHOP FABRICATION AND FIELD ERECTION WELDING. 1.WELDING PROCEDURE SPECIFICATIONS (WPS): WELDING SHALL BE DONE WITH APPROPRIATE WELD PROCEDURES PREPARED IN ACCORDANCE WITH AWS D1.1, AWS D1.8 CLAUSES 6.1. SUBMIT FOR REVIEW PER AISC 341 SECTION 2.FILLER METAL: WELDS OF MEMBERS OF THE SFRS SHALL BE MADE WITH FILLER METAL CONFORM TO THE REQUIREMENTS OF AISC 341 SECTION A3.4 AND AWS D1.8 CLAUSES 6.3, WHICH CAN PRODUCE WELDS THAT HAVE MINIMUM CHARPY V-NOTCH TOUGHNESS OF 20 FOOT-POUNDS AT 0 DEGREES FAHRENHEIT. SUBMIT EVIDENCE OF COMPLIANCE. 3.WELD (RUNOFF) TABS: REMOVE WELD (RUNOFF) TABS, UNLESS NOTED OTHERWISE, AND GRIND SURFACES PER AWS D1.8 CLAUSES 6.11 UNLESS NOTED OTHERWISE. 4.CONTINUINTY PLATES AND STIFFENERS PLACED INTO THE WEBS OF ROLLED SHAPED SHALL BE DETAILED IN ACCORDANCE WITH AWS D1.8 CLAUSES 4.1. 5.WELD ACCESS HOLES OF DEMAND CRITICAL WELDS SHALL EITHER BE PER AWS D1.8 SECTION 6.10.1.2. OR AS OTHERWISE PERMITTED PER AISC 360 SECTION J1.6. 6.BACKING BARS: a. BACKING IN GROOVE WELDED BUTT SPLICED OF COLUMNS NEED NOT BE REMOVED b. BACKING IN GROOVE WELDS OF COLUMNS TO BASEPLATES SHALL BE REMOVED EXCEPT WHEN BACKING IS PLACED AND REINFORCED PER THE REQUIREMENTS OF AISC 341 SECTION D2.6 7.TACK WELDS: ALL TACK WELDS PART OF THE SFRS SHALL COMPLY WITH REQUIREMENTS OF AWS D1.8 SECTION 6.16. 8.DEMAND CRITICAL WELDS (DCW): WELDS DESIGNATED AS “DEMAND CRITICAL WELDS” OR “DCW” IN THE TAIL OF WELD SYMBOLS ON DRAWINGS SHALL COMPLY WITH THE ADDITIONAL REQUIREMENTS OF SECTIONS A3.4B AND I2.3 IN AISC 341 AND SHALL BE MADE WITH FILLER METALS CAPABLE OF PROVIDING A MINIMUM CHARPY V-NOTCH TOUGHNESS OF 20 FT-LB AT 0 DEGREES FAHRENHEIT AND 40 FT-LB AT 70 DEGREES FHARENHEIT AS DETERMINED BY THE APPROPRIATE AWS CLASSIFICATION TEST METHOD OR MANUFACTURER CERTIFICATION. UNLESS OTHERWISE NOTES, THE FOLLOWING NOTED, THE FOLLOWING WELDS IN THE SFRS SHALL BE CONSIDERED “DEMAND CRITICAL”: 9. COMPLETE-JOINT-PENETRATION (CJP) GROOVE WELDS OF: a. COLUMN SPLICES b. COLUMN-TO-BASEPLATE c. BEAM FLANGE-TO-COLUMN FLANGE, UNLESS OTHERWISE NOTED IN AISC 358 d. BEAM WEB-TO-COLUMN FLANGE, UNLESS OTHERWISE NOTED IN AISC 358 STEEL STAIRS REFERENCE STANDARDS: CONFORM TO: 1. CBC CHAPTER 10 - “MEANS OF EGRESS”, CBC TABLE 1607.1 2. NAAMM - “METALS STAIRS MANUAL” 3. ANSI/AISC 360-10 - “SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS” 4. AISI 2007 - “NORTH AMERICA SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS” 5. AWS D1.1-0 “STRUCTURAL WELDING CODE- STEEL”, 6. AWS D1.3-08 “STRUCTURAL WELDING CODE- SHEET STEEL.” SUBMITTALS: STEEL STAIRS ARE TO BE PREPARED BY A SSE. REFERENCE DEFINITIONS AND DEFERRED SUBMITTALS ABOVE. SUBMIT STRUCTURAL CALCULATIONS AND SHOP DRAWINGS (COMPONENT DESIGN DRAWINGS) STAMPED BY A PROFESSIONAL CIVIL PF STRUCTURAL ENGINEER REGISTERED OM THE STATE OF CALIFORNIA. MATERIALS: STRUCTURAL WF SHAPES…………………............................ASTM A992 - GR50 STEEL CHANNELS, ANGLES, AND PLATES & BAR...............ASTM A36 SHEET STEEL (GALVANIZED)………………...........................ASTM A446 STEEL PIPE RAIL……………………………..............................ASTM A53, GRADE B STEEL TUBING ……………………………................................ASTM A500, GRADE B STEEL ROD…………………………………...............................ASTM A36 OR A307 STEEL DECK……………………………….................................1- ½” COMPOSITE FLOOR DECK BOLTS……………………………………….................................ASTM A325N WELDS, STRUCTURAL STEEL………………….AWS D1.1 WELDS, SHEET STEEL………………………......AWS D1.3 WELDED HEADED STUDS (WHS)………….......ASTM A108, AWS D1.1 HEADED CONCRETE ANCHORS (HCA)……….ASTM A108, AWS D1.1 STRUCTURAL REQUIREMENTS: 1.SCOPE: INCLUDE TREADS, RISERS, STINGERS, LANDINGS, RAILINGS AND ALL CONNECTIONS INCLUDING CONNECTIONS TO THE PRIMARY STRUCTURE UNLESS NOTED OTHERWISE. ALL INSERTS REQUIRED FOR ATTACHMENT TO THE PRIMARY STRUCTURE SHALL BE DESIGNED AND PROVIDED BY THE STAIR SUPPLIER. 2.LOADS: STAIR TREADS SHALL BE DESIGNED FOR 100 PSF LIVE LOAD OR 300LB. CONCENTRATED LOAD PLACED TO PRODUCE MAXIMUM STRESS, WHICHEVER CONTROLS. STRINGERS AND LANDINGS SHALL BE DESIGNED FOR 100 PSF LIVE LOAD. LIVE LOAD DEFLECTION SHALL NOT EXCEED 1/360 OF THE SPAN. THE STAIR ASSEMBLY AND ATTACHMENT TO THE MAIN STRUCTURE SHALL BE DESIGNED FOR LATERAL LOADS PER CBC CHAPTER 16 3.RAILINGS: THE COMPLETED HANDRAIL, GUARDRAIL, AND SUPPORTING STRUCTURE AND THEIR CONNECTIONS SHALL BE DESIGNED TO RESIST LOADS AS SPECIFIED IN THE CBC SECTION 1607.8. 4.ARCHITECTURAL REQUIREMENTS: CONFORM TO SHAPE AND CONFIGURATION SHOWN ON THE ARCHITECTURAL DRAWINGS. CONSULT THE PROJECT SPECIFICATIONS FOR ADDITIONAL INFORMATION. ALL STEEL SHALL BE PAINTED PER PROJECT SPECIFICATIONS WITH ONE COAT OF STANDARD SHOP PRIMER UNLESS NOTED OTHERWISE ON THE DRAWINGS OR IN THE SPECIFICATIONS 5.CONCRETE FILL: CONFORM TO NOTES, THIS SHEET FOR CAST-IN-PLACE CONCRETE AND CONCRETE REINFORCEMENT. PROVIDE MINIMUM 3000 PSI CONCRETE AND WWF 6X6-W1.4 OR FIBER MESH UNLESS NOTED ON THE DRAWINGS. STRUCTURAL (S), (W) & (HP) SHAPES CHANNEL (C) & ANGLE (L) SHAPES STRUCTURAL PLATE (PL) HIGH STRENGTH PLATE (GR 50 PL) HOLLOW STRUCTURAL SECTION-SQUARE/RECT(HSS) STRUCTURAL PIPE (PIPE) 12” DIA. AND LESS HOLLOW STRUCTURAL SECTION-ROUND (HSS) HEAVY HEX NUTS WASHERS (HARDENED FLAT OR BEVELED) ANCHOR RODS (ANCHOR BOLTS, TYPICAL) MILD THREADED RODS HIGH STRENGTH THREADED RODS ASTM A992 FY=50 KSI HIGH STRENGTH THREADED RODS WELDED HEADED (SHEAR) STUD ANCHORS WELDED HEADED STUD (WHS) ANCHORS DOWEL BAR ANCHORS (DBA) ASTM A36, FY=36 KSI ASTM A36 FY=36 KSI ASTM A36 FY=36 KSI ASTM A572 FY=50 KSI ASTM A500 GRADE B FY= 46 KSI ASTM A53 GRADE B FY= 35 KSI ASTM A325/F1852 TYPE 1 OR 3, PLAIN OR GALVANZED (AS REQ'D) ASTM A563 GRADE AND FINISH PER RCS TABLE 2.1 ASTM F436 GRADE AND FINISH PER RCSC TABLE 2.1 ASTM F1554 GR.36 ASTM F1554 GR.55 (WELD ABLE) PER SUPPLEMENT S1 ASTM A36 FY= 36 KSI ASTM A36 FY= 50 KSI ASTM A193 GRADE B7 FY = 100 KSI ASTM A108-NELSON/TRW S3L HIGH STRENGTH HEAVY HEX STRUCTURAL BOLTS ASTM A500 GRADE B FY= 42 KSI ANCHOR RODS (HIGH STRENGTH) ASTM A496- NELSON/TRW D2L FY = 70 KSI ASTM A108 NELSON /TRW H4L STRUCTURAL STEEL MATERIALS WIDE FLANGE (WF), TEE (WT) SHAPES S-0.12 ST R U C T U R A L N O T E S MEMBER SIZES SPECIES COMB. SYMBOL USES Beams All DF/DF 24F-V4 Simple Spans Beams All DF/DF 24F-V4 Continuous or with Cantilever Spans Columns All DF L2 Post, Truss Member DATE:11/14/2024 JOB NO: MLB24-1210 DESIGNED BY: HK CHECKED BY: GB DE S C R I P T I O N DA T E RE V BY 1 3 4 5 - 2 - - MLB CONSULTING AND ENGINEERING, INC 7918 FOOTHILL BLVD SUNLAND, CA 91040 (818) 521-6342 INFO@MLBENGINEERING.ORG 4703 W McFadden Ave Santa Ana, CA 92704 DATE:11/14/2024 JOB NO: MLB24-1210 DESIGNED BY: HK CHECKED BY: GB DE S C R I P T I O N DA T E RE V BY 1 3 4 5 - 2 - - MLB CONSULTING AND ENGINEERING, INC 7918 FOOTHILL BLVD SUNLAND, CA 91040 (818) 521-6342 INFO@MLBENGINEERING.ORG 4703 W McFadden Ave Santa Ana, CA 92704 WOOD FRAMING REFERENCE STANDARDS: CONFORM TO: 1. CBC CHAPTER 23 "WOOD" 2. NDS - "2018 NATIONAL DESIGN SPECIFICATION (NDS) FOR WOOD CONSTRUCTION 3. ANSI/AWS - SDPWS-2015: SPECIAL DESIGN PROVISIONS FOR WIND & SEISMIC WITH COMMENTARY 4. APA PDS-04 PLYWOOD DESIGN SPECIFICATIONS 5. ANSI/TPI 1-2007 "NATIONAL DESIGN STANDARD FOR METAL-PLATE-CONNECTED WOOD TRUSS CONSTRUCTION" 6. BCSI "GUIDE TO GOOD PRACTICE FOR HANDLING, INSTALLING & BRACING OF METAL PLATED CONNECTED WOOD TRUSSES. 7. TPI DSB "RECOMMENDED DESIGN SPECIFICATION FOR TEMPORARY BRACING OF METAL PLATE CONNECTED WOOD TRUSSES" 8. APA REPORT TT-045B "MINIMUM NAIL PENETRATION FOR WOOD STRUCTURAL PANEL CONNECTIONS SUBJECT 9. TO LATERAL LOADS" SUBMITTALS: SUBMIT SHOP DRAWINGS TO ARCHITECT/ENGINEER FOR REVIEW. SHOP DRAWINGS SHALL INCLUDE MEMBER SIZE, SPACING, CAMBER, MATERIAL TYPE, GRADE, SHOP AND FIELD ASSEMBLY DETAILS AND CONNECTIONS, TYPES AND LOCATION OF BOLTS AND OTHER FASTENERS. SUPPLY SHOP DRAWINGS FOR THE FOLLOWING: 1. GLUED LAMINATED MEMBERS 2. PSL MEMBERS 3. LVL MEMBERS 4. LSL MEMBERS 5. TAPERED & PARALLEL WOOD I JOISTS (SOLID WEB-WOOD JOISTS) 6. PANELIZED WOOD WALLS & CONNECTION DETAILS 7. WOOD TIE-DOWN SYSTEMS DEFERRED SUBMITTALS: SUBMIT PRODUCT DATA AND PROOF OF ICC APPROVAL FOR FRAMING MEMBERS AND FASTENERS THAT HAVE BEEN DESIGNED BY OTHERS. SUBMIT CALCULATIONS PREPARED BY THE EOR IN THE STATE OF CALIFORNIA FOR ALL MEMBERS AND CONNECTIONS DESIGN BY OTHERS ALONG WITH SHOP DRAWINGS. ALL NECESSARY BRIDGING, BLOCKING, BLOCKING PANELS AND WEB STIFFENERS SHALL BE DETAILED AND FURNISHED BY THE SUPPLIER. TEMPORARY AND PERMANENT BRIDGING SHALL BE INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S SPECIFICATIONS. DEFLECTION LIMITS SHALL BE NOTED UNDER "DEFERRED SUBMITTALS" SECTION SPECIFIC DETAILS. PRODUCTS INCLUDED ARE: 1.SOLID WEB WOOD JOISTS (I-JOISTS) 2.WOOD TIE DOWN SYSTEMS: CONTINUOUS ROD HOLD-DOWN SYSTEMS, WITH TAKE-UP DEVICES, SHALL BE SPECIFIED. TAKE-UP DEVICES ARE REQUIRED AT EACH FRAMING LEVEL. ADDITIONAL FRAMING MEMBERS SHALL BE PROVIDED PER THE SYSTEM REQUIREMENTS REFER TO DETAILS AND LOADING ON THE STRUCTURAL DRAWINGS. IDENTIFICATIONS: ALL SAWN LUMBER AND PRE-MANUFACTURED WOOD PRODUCTS SHALL BE IDENTIFIED BY THE GRADE MARK OR A CERTIFICATE OF INSPECTION ISSUED BY THE CERTIFYING AGENCY. MATERIALS: 1.SAWN LUMBER: CONFORM TO GRADING RULES OF WWPA, WCLIB OR NLGA AND "TABLE OF SAWN LUMBER" FOUND ON THIS SHEET. FINGER JOINTED STUDS ACCEPTABLE AT INTERIOR WALLS ONLY. 2.WOOD STRUCTURAL SHEATHING (PLYWOOD): WOOD APA-RATED STRUCTURAL SHEATHING INCLUDES: ALL VENEER PLYWOOD, ORIENTED STRAND BOARD, WAFERBOARD, PARTICLEBOARD, T1-11 SLIDING, AND COMPOSITES OF VENEER AND WOOD BASED MATERIAL WITH T&G JOINT. ARCHITECT MAY DISALLOW OSB. CONFIRM WITH ARCHITECT. CONFORM TO "CONSTRUCTION AND INDUSTRIAL PLYWOOD" BASED ON PRODUCT STANDARD PS 1-07 BY THE U.S. DEPT OF COMMERCE, AND "PERFORMANCE STANDARD FOR WOOD-BASED STRUCTURAL-USE PANELS" BASED ON PRODUCT PS 2-04 BY THE U.S. DEPT. IF CINNERCE AND "PLYWOOD DESIGN SPECIFICATION" BASED ON APA PDS-04 BY THE AMERICAN PLYWOOD ASSOCIATION. UNLESS NOTED OTHERWISE, SHEATHING SHALL COMPLY WITH THE "TABLE OF SHEATHING" FOUND ON THIS SHEET. 3.GLUED LAMINATED TIMBER: CONFORM TO AITC 117-2004 "STANDARD SPECIFICATIONS FOR STRUCTURAL GLUE-LAMINATED TIMBER OF SOFTWOOD SPECIES, MANUFACTURING AND DESIGN" AND ANSI/AITC A190.1 "STRUCTURAL GLUED LAMINATED TIMBER." CAMBER ALL GLUED LAMINATED BEAMS, EXCEPT CANTILEVERED AND CONTINUOUS BEAMS, TO 3000' RADIUS, UNLESS SHOWN OTHERWISE ON PLANS. 4.ENGINEERED WOOD PRODUCTS (TrusJoist): THE FOLLOWING MATERIALS ARE BASED ON LUMBER MANUFACTURED BY TrusJoist AND WERE USED FOR THE DESIGN AS SHOWN ON PLANS. ALTERNATE PRODUCTS BY OTHER MANUFACTURERS MAY BE SUBSTITUTED PROVIDED THEY HAVE CURRENT ICC APPROVAL FOR EQUIVALENT OR GREATER LOAD AND STIFFNESS PROPERTIES AND ARE REVIEWED AND APPROVED BY THE EOR. A HUD MATERIAL RELEASE FORM IS REQUIRED FORE ALL MANUFACTURED WOOD PRODUCTS LISTED BELOW: a.LAMINATED VENEER LUMBER (LVL): CONFORM TO ICC-ES REPORT NO. ESR-1387 OR CCMC REPORT NO. 08675-R. b.PARALLEL STRAND LUMBER (PSL): CONFORM TO ICC-ES REPORT NO. ESR-1387 OR CCMC REPORT NO. 11161-R c.LAMINATED STRAND LUMBER (LSL): CONFORM TO ICC REPORT NO. ESR-1387 OR CCMC REPORT NO. 12627-R. d.PARALLEL CHORD I-JOISTS (DEFERRED SUBMITTAL): CONFORM TO ICC REPORT NO. ESR-1153. THE MANUFACTURER SHALL DESIGN THE JOISTS FOR THE SPANS AND CONDITIONS SHOWN ON THE PLANS. JOISTS SHALL HAVE WOOD CHORDS AND SOLID WOOD WEBS. JOISTS SHALL BE TAPERED OR PARALLELL AS SHOWN ON THE PLANS. 5.TIMBER CONNECTORS: SHALL BE "STRONG TIE" BY SIMPSON COMPANY AS SPECIFIED IN THEIR LATEST CATALOG. ALTERNATE CONNECTORS BY OTHER MANUFACTURERS MAY BE SUBSTITUTED PROVIDED THEY HAVE CURRENT ICC APPROVAL FOR EQUIVALENT OR GREATER LOAD CAPACITIES AND ARE REVIEWED AND APPROVED BY THE SER. PRIOR TO ORDERING. CONNECTORS SHALL BE INSTALLED PER THE MANUFACTURER'S INSTRUCTIONS. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS OR BOLTS IN EACH MEMBER. WHERE STRAPS ARE USED AS HOLD-DOWNS, NAIL STRAPS TO WOOD FRAMING JUST PRIOR TO DRYWALL APPLICATION, AS LATE AS POSSIBLE IN THE FRAMING PROCESS TO ALLOW WOOD TO SHRINK AND THE BUILDING TO SETTLE. PREMATURE NAILING OF THE STRAP MAY LEAD TO STRAP BUCKLING AND POTENTIAL FINISH DAMAGE. 6. WHERE CONNECTORS ARE IN EXPOSED EXTERIOR APPLICATIONS IN CONTACT WITH PRESERVATIVE TREATED WOOD (PT) OTHER THAN CCA, CONNECTORS SHALL BE EITHER BATCH HOT-DIPPED GALVANIZED (HDG), MECHANICALLY GALVANIZED (ASTM B695, CLASS 55 MINIMUM) STAINLESS STEEL, OR PROVIDED WITH 1.85 OZ/SF OF ZINC GALVANIZING EQUAL TO OR BETTER THAN SIMPSON ZMAX FINISH. 7.FASTENERS: (NAILS, BOLTS, SCREWS, ETC) ATTACHING TIMBER CONNECTORS (JOIST HANGERS, POST CAPS, AND BASSES, ETC) TO PT WOOD SHALL HAVE SIMILAR CORROSION RESISTANT PROPERTIES (MATCHING PROTECTIVE TREATMENTS) AS THE PROTECTED CONNECTOR. FASTENERS (NAILS, BOLTS, SCREWS, ETC.) ATTACHING SAWN TIMBER MEMBERS OR SHEATHING (SHEAR WALLS) TO PT WOOD SHALL BE CORROSION RESISTANT; NAILS AND LAG BOLTS SHALL BE EITHER HDG (ASTM A153) OR STAINLESS STEEL. VERIFY THE SUITABILITY OF THE FASTENER PROTECTION/COATING WITH THE WOOD TREATMENT CHEMICAL MANUFACTURER/SUPPLIER. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. 8.LAG BOLTS/BOLTS: CONFORM TO ASTM A307 AND CBC SECTION 2304.9 ROOF AND FLOOR PANELS: UNLESS NOTED OTHERWISE ON DRAWINGS, INSTALL ROOF AND FLOOR PANELS WITH LONG DIMENSIONS ACROSS SUPPORTS AND WITH PANEL CONTINUOUS OVER TWO OR MORE SPANS. END JOINTS SHALL OCCUR OVER SUPPORTS. HUD MATERIALS BULLETIN 40C GRADE MARKING OF SHEATHING CERTIFICATION IS REQUIRED. NAILING REQUIREMENTS: CONFORM TO CBC SECTION 2304.9 "CONNECTIONS AND FASTENERS." UNLESS NOTED ON PLANS, NAIL PER TABLE 2304.9.1. NAILING FOR ROOF/FLOOR DIAPHRAGMS/SHEARWALLS SHALL BE PER DRAWINGS. NAILS SHALL BE DRIVEN FLUSH AND SHALL NOT FRACTURE THE SURFACE OF SHEATHING. ALTERNATE NAILS MAY BE USED BUT ARE SUBJECT TO REVIEW AND APPROVAL BY THE EOR. SUBSTITUTION OF STAPLES FOR THE NAILING OF RATED SHEATHING IS SUBJECT TO REVIEW BY THE EOR PRIOR TO CONSTRUCTION. STANDARD LIGHT-FRAME CONSTRUCTION: UNLESS NOTED ON THE PLANS, CONSTRUCTION SHALL CONFORM TO CBC SECTION 2308 "CONVENTIONAL LIGHT-FRAME CONSTRUCTION." NAILERS ON STEEL COLUMNS AND BEAMS: WOOD 3X NAILERS ARE GENERALLY REQUIRED ON ALL HSS COLUMNS AND STEEL BEAMS ABUTTING OR EMBEDDED WITHIN WOOD FRAMING. UNLESS NOTED OTHERWISE, ATTACH WITH 5/8" DIAMETER BOLTS OR WELDED STUDS @ 16" ON CENTERS. WOOD NAILERS ON BEAMS SUPPORTING JOIST HANGER SHALL BE FLUSH WITH BEAM FLANGE. MOISTURE CONTENT: WOOD MATERIAL USED FOR THIS PROJECT SHALL HAVE MAXIMUM MOISTURE CONTENT OF 19% EXCEPT FOR THE PRESSURE-TREATED WOOD SILL PLATE. REFER TO "TESTING & INSPECTIONS" FOR THE VERIFICATION OF THESE LIMITS. THE MAXIMUM MOISTURE CONTENT REQUIRED MAY BE LESS THAN 19% WHEN BASED ON A PARTICULAR CLADDING/INSULATION SYSYTEM. REFER TO THE ARCHITECTURAL DRAWINGS, AND PROJECT SPECIFICATIONS, OR WITH CLADDING INSTALLER FOR MAXIMUM RECOMMENDED MOISTURE CONTENT. SHRINKAGE COMPENSATION FOR MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS: MEP SYSTEMS, INCLUDING DUCTWORK, PIPES, AND OTHER ELEMENTS THAT RUN CONTINUOUSLY BETWEEN LEVELS SHALL BE INSTALLED/DESIGNED IN SUCH A MANNER TO ACCOMMODATE SHRINKAGE IN THE WOOD FRAMING. WOOD SHRINKAGE AMOUNTS WILL VARY DEPENDING ON THE CONSTRUCTION PROCESS AND MATERIALS USED. THE ANTICIPATED SHRINKAGE UNDER TYPICAL CONDITIONS IS EXPECTED TO RANGE BETWEEN 1/8" TO 1/4" PER FLOOR. CLADDING COMPATIBILITY: THE ARCHITECT/OWNER SHALL REVIEW THE CLADDING AND INSULATION SYSTEMS PROPOSED FOR THE PROJECT WITH RESPECT TO THEIR PERFORMANCE OVER WOOD STUDS WITH MOISTER CONTENTS GREATER THAN 19%. EIFS SYSTEMS SHOULD BE AVOIDED ON WOOD-FRAMED PROJECTS DUE TO PROBLEMS WITH MOISTURE PROOFING. PRESERVATIVE TREATMENT (PT): WOOD MATERIALS ARE REQUIRED TO BE "TREATED WOOD" IN ACCORDANCE WITH CBC SECTION 2304.11 "DECAY AND TERMITE PROTECTION" SHALL CONFORM TO THE APPROPRIATE STANDARDS OF THE AMERICAN WOOD PRESERVERS ASSOCIATION (AWPA) FOR SAWN LUMBER, GLUED LAMINATED TIMBER, ROUND POLES, WOOD PILES AND MARINE PILES. FOLLOW AMERICAN LUMBER STANDARDS COMMITTEE (ALSC) QUALITY ASSURANCE PROCEDURES. PRODUCTS SHALL BEAR THE APPROPRIATE MARK. FASTENERS OR ANCHORS IN TREATED WOOD SHALL BE OF STAINLESS STEEL OR HOT-DIPPED GALVANIZED OR AS PER CBC 2304.9.5. HUD UM48a PRESSURE-TREATED LUMBER AND PLYWOOD CERTIFICATION IS REQUIRED. MEMBER USE SIZE SPECIES GRADE Stud 2x4, 3x4, 2x6, 3x6 Doug Fir Larch No.2 Sill Plate 2x4, 3x4, 2x6, 3x6 PT Doug Fir Larch No.2 Post 4x4, 4x6, 4x8 Doug Fir Larch No.2 Floor or Roof Joist 2x6 through 2x12 Doug Fir Larch No.2 Beam 4x8 through 4x12 Doug Fir Larch No.2 Beam 6x8 through 6x12 Doug Fir Larch No.1 Post or Timber 6x6, 8x8 Doug Fir Larch No.1 TABLE OF SAWN LUMBER LOCATION THICKNESS SPAN RATING PLYWOOD GRADE EXPOSURE Roof 15/32"32/16 C-D 1 Floor 23/32" T&G 24 OC STUD-I-FLOOR 1 Walls 15/32"32/16 C-D 1 TABLE OF SHEATHING - USE, MINIMUM THICKNESS AND MINIMUM APA RATING TYPE USE WIDTHS E (106) (psi)Fb (psi)Fv (psi) Fc// (psi) LSL Rimboard Rimboard or Stair Stringer 1 1/2"1.3E 1700 400 1835 Timberstrand LSL Header, Beam or Column < 9" depth 3 1/2"1.3E 1700 400 1835 Timberstrand LSL Rimboard, Header or Beam ≥ 9" depth 1 3/4" , 3 1/2"1.55E 2325 310 2170 Timberstrand LSL Wall Stud 2x4 & 2x6 1 1/2"1.3E 1700 400 1300 Wall Stud > 2x6 1 1/2"1.5E 2250 400 1950 Microllam LVL Header, Beam 1 3/4"2.0E 2600 285 2510 Parallam PSL Header, Beam 3 1/2" , 5 1/4", 7"2.0E 2900 290 2900 Parallam PSL Column 3 1/2" , 5 1/4", 7"1.8E 2400 190 2500 TABLE OF ENGINEERED WOOD REQUIREMENTS TABLE OF GLULAM AND GRADE S-0.13 ST R U C T U R A L N O T E S Wood structural panels, combination subfloor underlayment to framing 35. 3/4" and less 8d common (2 1/2" x 0.131"); or 6d deformed (2" x 0.113")6 12 36. 7/8" - 1"8d common (2 1/2" x 0.131"); or 8d deformed (2 1/2" x 0.131")6 12 37. 1 1/8" - 1 1/4"10d common (3" x 0.148"); or 8d deformed (2 1/2" x 0.131")6 12 ROOF 1. Blocking between ceiling joists rafters or trusses to top plate or framing below 3-8d common (2 1/2" X 0.131"); or 3-10d box (3" X 0.128"); or 3-3" 0.131" nails; or 3-3" 14 gage staples, 7/16" crown Each end, toenail Blocking between rafters or truss not at the wall top plate, to rafter or truss 2-8d common (2 1/2" X 0.131") 2-3" x 0.131" nails 2-3" 14 gage staples Each end, toenail 2-16d common (3 1/2" x 0.162" 3-3" x 0.131" nails 3-3" 14 gage staples End nail Flat blocking to truss and web filler 16d common (3 1/2" x 0.162") @ 6" o.c. 3" x 0.131" nails @ 6" o.c. 3" x 14 gage staples @ 6" o.c. Face nail 2. Ceiling joists to top plate 3-8d common (2 1/2" x 0.131"); or 3-10d box (3" x 0.128"); or 3-3" x 0.131" nails; or 3-3" 14 gage staples, 7/16" crown Each joist, toenail 3. Ceiling joist not attached to parallel rafter, laps over partitions (no thrust) (see Section 2308.7.3.1, Table 2308.7.3.1) 3-16d common (3 1/2" x 0.162"); or 4-10d box (3" X 0.128"); or 4-3" x 0.131" nails; or 4-3" 14 gage staples, 7/16" crown Face nail 4. Ceiling joist attached to parallel rafter (heel joint) (see Section 2308.7.3.1, Table 2308.7.3.1)Per Table 2308.7.3.1 Face nail 5. Collar tie to rafter 3-10d common (3 1/2" x 0.148"); or 4-10d box (3" X 0.128"); or 4-3" x 0.131" nails; or 4-3" 14 gage staples, 7/16" crown Face nail 6. Rafter or roof truss to itop plate (See Section 2308.7.5, Table 2308.7.5) 3-10d common (3 1/2" x 0.148"); or 3-16d box (3 1/2" x 0.135"); or 4-10d box (3" x 0.128"); or 4-3" x 0.131" nails; or 4-3" 14 gage staples, 7/16" crown Toenailc 7. Roof rafters to ridge valley or hip rafters; or roof rafter to 2-inch ridge beam 2-16d common (3 1/2" x 0.162"); or 3-10d box (3 1/2" x 0.128"); or 3-3" x 0.131 nails; or 3-3" 14 gage staples, 7/16" crown; or End nail 3-10d common (3 1/2" x 0.148"); or 4-16d box (3 1/2" x 0.135"); or 4-10d box (3" x 0.128"); or 4-3" x 0.131" nails; or 4-3" 14 gage staples, 7/16" crown Toenail WALL 8. Stud to stud (not at braced wall panels) 16d common (3 1/2" x 0.162");24" o.c. face nail 10d box (3" x 0.128"); or 3" x 0.131" nails; or 3-3" 14 gage staples, 7/16" crown 16" o.c. face nail 9. Stud to stud and abutting studs at intersecting wall corners (at braced wall panels) 16d common (3 1/2" x 0.162"); or 16" o.c. face nail 16d box (3 1/2" x 0.135"); or 12" o.c. face nail 3" x 0.131" nails; or 3-3" 14 gage staples, 7/16" crown 12" o.c. face nail 10. Built-up header (2" to 2" header) 16d common (3 1/2" x 0.162"); or 16" o.c. each edge, face nail 16d box (3 1/2" x 0.135")12" o.c. each edge, face nail 11. Continuous header to stud 4-8d common (2 1/2" x 0.131"); or 4-10d box (3" x 0.128")Toenail 12. Top plate to top plate 16d common (3 1/2" x 0.162"); or 16" o.c. face nail 10d box (3" x 0.128"); or 3" x 0.131" nails; or 3" 14 gage staples, 7/16" crown 12" o.c. face nail 13. Top plate to top plate, at end joints 8-16d common (3 1/2" x 0.162"); or 12-10d box (3 1/2" x 0.128"); or 12-3" x 0.131" nails; or 12-3" 14 gage staples, 7/16" crown Each side of end joint, face nail (minimum 24" lap splice length each side of end joint) 14. Bottom plate to joist, rim joist, band joist or blocking (not at braced wall panels) 16d common (3 1/2" x 0.162"); or 16" o.c. face nail 16d box (3 1/2" x 0.135"); or 3" x 0.131" nails; or 3" 14 gage staples, 7/16" crown 12" o.c. face nail 15. Bottom plate to joist, rim joist, band joist or blocking at braced wall panels 2-16d common (3 1/2" x 0.162"); or 3-16d box (3 1/2" x 0.135"); or 4-3" x 0.131" nails; or 4-3" 14 gage staples, 7/16" crown 16" o.c. face nail 16. Stud to top or bottom plate 4-8d common (2 1/2" x 0.131"); or 4-10d box (3" x 0.128"); or 4-3" x 0.131" nails; or 4-3" 14 gage staples, 7/16" crown or Toenail 2-16d common (3 1/2" x 0.162"); or 3-10d box (3 1/2" x 0.128"); or 3-3" x 0.131" nails; or 3-3" 14 gage staples, 7/16" crown End nail 17. Top plates, laps at corners and intersections 2-16d common (3 1/2" x 0.131"); or 3-10d box (3 1/2" x 0.128"); or 3-3" x 0.131" nails; or 3-3" 14 gage staples, 7/16" crown Face nail 18. 1" brace to each stud and plate 2-8d common (2 1/2" x 0.131"); or 2-10d box (3 1/2" x 0.128"); or 2-3" x 0.131" nails; or 2-3" 14 gage staples, 7/16" crown Face nail 19. 1" x 6" sheathing to each bearing 2-8d common (2 1/2" x 0.131"); or 2-10d box (3 1/2" x 0.128"); or Face nail 20. 1" x 8" and wider sheathing to each bearing 3-8d common (2 1/2" x 0.131"); or 3-10d box (3 1/2" x 0.128"); or Face nail FLOOR 21. Joist to sill, top plate, or girder 3-8d common (2 1/2" x 0.131"); or 3-10d box (3 1/2" x 0.128"); or 3-3" x 0.131" nails; or 3-3" 14 gage staples, 7/16" crown Toenail 22. Rim joist, band joist, or blocking to top plate, sill or other framing below 8d common (2 1/2" x 0.131"); or 10d box (3" x 0.128"); or 3-3" x 0.131" nails; or 3-3" 14 gage staples, 7/16" crown 6" o.c., toenail 23. 1" x 6" subfloor or less to each joist 2-8d common (2 1/2" x 0.131"); or 2-10d box (3" x 0.128")Face nail 24. 2" subfloor to joist or girder 2-16d common (3 1/2" x 0.162")Face nail 25. 2" planks (plank & beam - floor & roof)2-16d common (3 1/2" x 0.162")Each bearing, face nail 26. Built-up girders and beams, 2" lumber layers 20d common (4" x 0.192") 32" o.c., face nail at top and bottom staggered on opposite sides 10d box (3" x 0.128"); or 3" x 0.131" nails; or 3" 14 gage staples, 7/16" crown 24" o.c., face nail at top and bottom staggered on opposite sides And: 2-20d common (4" x 0.192); or 3-10d box (3" x 0.128"); or 3-3" x 0.131" nails; or 3-3" 14 gage staples, 7/16" crown Ends and at each splice, face nail 27. Ledger strip supporting joists or rafters 3-16d common (3 1/2" x 0.162"); or 4-10d box (3" x 0.128"); or 4-3" x 0.131" nails; or 4-3" 14 gage staples, 7/16" crown Each joist or rafter, face nail 28. Joist to band joist or rim joist 3-16d common (3 1/2" x 0.162"); or 4-10d box (3" x 0.128"); or 4-3" x 0.131" nails; or 4-3" 14 gage staples, 7/16" crown End nail 29. Bridging or blocking to joist, rafter or truss 2-8d common (2 1/2" x 0.131"); or 2-10d box (3" x 0.128"); or 2-3" x 0.131" nails; or 2-3" 14 gage staples, 7/16" crown Each end, toenail Wood structural panels (WSP), subfloor, roof and interior wall sheathing to framing and particle wall sheathing to framinga Edges (inches) Intermediate supports (inches) 30. 3/8" - 1/2" 6d common or deformed (2" x 0.113") (subfloor and wall)6 12 8d common or deformed (2 1/2" x 0.131") (roof) or RSRS-01 (2 3/8" x 0.113") nail (roof)d 6 12 2 3/8" x 0.113" nail (subfloor and wall)6 12 1 3/4" 16 gage staple, 7/16" crown (subfloor and wall)4 8 2 3/8" x 0.113" nail (roof)4 8 1 3/4" 16 gage staple, 7/16" crown (roof)3 6 31. 19/32" - 3/4" 8d common (2 1/2" x 0.131"); or 6d deformed (2" x 0.113") (subfloor and wall) 6 12 8d common or deformed (2 1/2" x 0.131") (roof) or RSRS-01 (2 3/8" x 0.113") nail (roof)d 6 12 2 3/8" x 0.113" nail; or 2" 16 gage staple, 7/16" crown 4 8 32. 7/8" - 1/4"10d common (3" x 0.148"); or 8d deformed (2 1/2" x 0.131")6 12 Other Exterior Wall Sheathing 33. 1/2" fiberboard sheathingb 1 1/2" galvanized roofing nail (7/16" head diameter); or 1 1/4" 16 gage staple with 7/16" or 1" crown 3 6 34. 19/32" - 3/4" 1 3/4" galvanized roofing nail (7/16" head diameter); or 1 1/2" 16 gage staple with 7/16" or 1" crown 3 6 Interior paneling 40. 1/4"4d casing (1 1/2" x 0.080"; or 4d finish (1 1/2" x 0.072")6 12 41. 3/8"6d casing (2" x 0.099"; or 6d finish (Panel supports at 24 inches)6 12 Panel siding to framing 38. 1/2" or less 6d corrosion-resistant siding (1 7/8" x 0.106"); or 6d corrosion-resistant casing (2" x 0.099") 6 12 39. 5/8" 8d corrosion-resistant siding (2 3/8" x 0.128"); or 8d corrosion-resistant casing (2 1/2" x 0.113") 6 12 FOR SI: 1 INCH = 25.4 mm. a. NAILS SPACED AT 6 INCHES AT INTERMEDIATE SUPPORTS WHERE SPANS ARE48 INCHES OR MORE. FOR NAILING OF WOOD STRUCTURAL PANEL AND PARTICLEBOARD DIAPHRAGMS AND SHEAR WALLS, REFER TO SECTION 2305. NAILS FOR WALL SHEATHING ARE PERMITTED TO BE COMMON, BOX OR CASING. b. SPACING SHALL BE 6 INCHES ON CENTER ON THE EDGES AND 12 INCHES ON CENTER AT INTERMEDIATE SUPPORTS FOR NONSTRUCTURAL APPLICATIONS. PANEL SUPPORTS AT 16 INCHES (20 INCHES IF STRENGTH AXIS IN THE LONG DIRECTION OF THE PANEL, UNLESS OTHERWISE MARKED). c. WHERE A RAFTER IS FASTENED TO AN ADJACENT PARALLEL CEILING JOIST IN ACCORDANCE WITH THIS SCHEDULE AND THE CEILING JOIST IS FASTENED TO THE TOP PLATE IN ACCORDANCE WITH THIS SCHEDULE, THE NUMBER OF TOENAILS IN THE RAFTER SHALL BE PERMITTED TO BE REDUCED TO ONE NAIL. d. RSRS-01 IS A ROOF SHEATHING RING SHANK NAIL MEETING THE SPECIFICATIONS IN ASTM F1667 NAILING SCHEDULE DATE:11/14/2024 JOB NO: MLB24-1210 DESIGNED BY: HK CHECKED BY: GB DE S C R I P T I O N DA T E RE V BY 1 3 4 5 - 2 - - MLB CONSULTING AND ENGINEERING, INC 7918 FOOTHILL BLVD SUNLAND, CA 91040 (818) 521-6342 INFO@MLBENGINEERING.ORG 4703 W McFadden Ave Santa Ana, CA 92704 DATE:11/14/2024 JOB NO: MLB24-1210 DESIGNED BY: HK CHECKED BY: GB DE S C R I P T I O N DA T E RE V BY 1 3 4 5 - 2 - - MLB CONSULTING AND ENGINEERING, INC 7918 FOOTHILL BLVD SUNLAND, CA 91040 (818) 521-6342 INFO@MLBENGINEERING.ORG 4703 W McFadden Ave Santa Ana, CA 92704 P/BC 2017-024 GENERAL NOTES FOR STRUCTURAL OBSERVATION (1) Structural Observation is required for the structural system in accordance with the Information Bulletin No. P/BC 2017-024. Structural Observation is the visual observation at the construction site of the elements and connections of the structural system at significant construction stages, and the complete structure for general conformance to the approved plans and specifications. Structural Observation does not waive the responsibility for the inspections required of the building inspector or the deputy inspector. (2) The owner shall employ a State of California registered civil or structural engineer or licensed architect to perform the Structural Observation. The Los Angeles Department of Building and Safety (LADBS) requires the use of the engineer or architect, or his/her designee responsible for the structural design who are independent of the contractor. (3) The Structural Observer shall provide evidence of employment by the owner or the owner’s representative. A letter from the owner, the owner’s representative, or a copy of the agreement for services shall be sent to the building inspector before the first site visit. (4) The owner or owner's representative shall coordinate and call for a meeting between the engineer or architect responsible for the structural design, Structural Observer, contractor, affected subcontractors and deputy inspectors. The purpose of the meeting shall be to identify the major structural elements and connections that affect the vertical and lateral load systems of the structure and to review scheduling of the required observations. A record of the meeting shall be included in the first observation report submitted to the building inspector. (5) The Structural Observer shall perform site visits at those steps in the progress of the work that allow for correction of deficiencies without substantial effort or uncovering of the work involved. At a minimum, the listed significant construction stages on either the “Structural Observation/Significant Construction Stages” form or the “Structural Observation Program and Designation of the Structural Observer” form IN/Form.08 (Part 2) require a site visit and an observation report from the Structural Observer. (6) The Structural Observer shall prepare a report of the “Structural Observation Report Form” IN/Form.08 (Part 1) for each significant stage of construction observed. The original of the Structural Observation report shall be sent to the building inspector's office and shall be signed and sealed (wet stamp) by the responsible Structural Observer. One copy of the observation report shall be attached to the approved plans. The copy attached to the plans shall be signed and sealed (wet stamp) by the responsible Structural Observer or their designee. Copies of the report shall also be given to the owner, contractor, and deputy inspector. Any deficiency noted on the observation report will become the responsibility of the structural engineer or architect of record to verify its completion by the Structural Observer. (7) A final observation report must be submitted which shows that all observed deficiencies were resolved and structural system generally conforms with the approved plans and specifications. The Los Angeles Department of Building and Safety (LADBS) will not accept the structural work without the final observation report and the correction of specific deficiencies noted during normal building inspection. (8) The Structural Observer shall provide the original stamped and signed “Structural Observation Report Form” to the City of Los Angeles Department of Building and Safety Building Inspector. (9) When there is a need to replace the Structural Observer of record, the owner shall: a) Notify the building inspector in writing before the next inspection by submitting completed “Structural Observation Program and Designation of the Structural Observer” form IN/Form.08 (Part 2). b) Call an additional preconstruction meeting, and c) Furnish the replacement Structural Observer with a copy of all previous observation reports. d) The new Structural Observer must be designated by the engineer or architect of record. The replacement Structural Observer shall approve the correction of the original observed deficiencies unless otherwise approved by plan check supervision. The policy of the Department shall be to correct any properly noted deficiencies without consideration of their source. (10) The engineer or architect of record shall develop all changes relating to the structural systems. The building department shall review and approve all changes to the approved plans and specifications. FOUNDATION (required if the Structural Observer is Signature License No. Date _________________________________________________________ individual is designated by me to be responsible for the Structural Observation. I, the Architect or Engineer of record for the project, declare that the above listed firm or DECLARATION BY ARCHITECT OR ENGINEER OF RECORD different from the Architect or Engineer of Record) Signature Date ________________________________________ DECLARATION BY OWNER I, the Owner of the project, declare that the above listed firm or individual is hired Structural Observer. STRUCTURAL OBSERVATION PROGRAM AND DESIGNATION OF THE STRUCTURAL OBSERVER Owner:__________________ Architect:____________________ Engineer:_____________________ Description of Work: PROJECT ADDRESS: 4703 W MCFADDEN AVE PERMIT APPL. NO.:___________________ (only checked items are required) STRUCTURAL OBSERVATION Firm or Individual to be responsible for the Structural Observation: Name: Phone: (818) 521-6342 Calif. Registration: C76761 DIAPHRAGMFRAMEWALL Others: Others: Wood Steel Deck ConcreteSteel Moment Frame Steel Braced Frame Concrete Moment Frame Masonry Wall Frame Concrete Masonry Wood Others: Others: Hillside Special Anchors Stepp' g/Retain' g Foundation, Caisson, Piles, Grade Beams Mat Foundation Footing, Stem Walls, Piers by me to be the REQUIRED NOTES ON PLANS MATERIAL SPECIFICATION & INSPECTIONS 1.CONTRACTORS RESPONSIBLE FOR THE CONSTRUCTION OF A WIND OR SEISMIC FORCE RESISTING SYSTEM/COMPONENT LISTED IN THE STATEMENT OF SPECIAL INSPECTION SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE LADBS INSPECTORS AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON SUCH SYSTEM OR COMPONENT. (1704.4) 2.CONTINUOUS SPECIAL INSPECTION BY A REGISTERED DEPUTY INSPECTOR IS REQUIRED FOR FIELD WELDING, POST-INSTALLED ADHESIVE ANCHORS INSTALLED HORIZONTALLY OR UPWARDLY INCLINED TO RESIST TENSION LOADS, SHOTCRETE PLACEMENT, CONCRETE STRENGTH f 'c > 2500 PSI, SPRAYED-ON FIREPROOFING, ENGINEERED MASONRY, HIGH-LIFT GROUTING, , HIGH LOAD DIAPHRAGMS AND SPECIAL MOMENT-RESISTING CONCRETE FRAMES, AND HELICAL PILE FOUNDATIONS. (1705 & CHAPTERS 19, 21, AND 22) 3. FOUNDATION SILLS SHALL BE NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. (2304.12.1.4) 4.FIELD WELDING TO BE DONE BY WELDERS CERTIFIED BY THE LADBS FOR (STRUCTURAL STEEL)(REINFORCING STEEL)(LIGHT GAUGE STEEL). CONTINUOUS INSPECTION BY A DEPUTY INSPECTOR IS REQUIRED. 5. SHOP WELDS MUST BE PERFORMED IN A LADBS LICENSED FABRICATOR'S SHOP. 6. LADBS LICENSED FABRICATOR IS REQUIRED FOR (TRUSSES), (STRUCTURAL STEEL). 7. GLUED-LAMINATED TIMBERS MUST BE FABRICATED IN A LADBS LICENSED SHOP. IDENTITY GRADE SYMBOL AND LAMINATION SPECIES PER 2018 NDS SUPPLEMENT TABLE 5A. 8.PROVIDE LEAD HOLE 40%-70% OF THREADED SHANK DIAMETER AND FULL DIAMETER FOR SMOOTH SHANK PORTION.\ 9.PERIODIC SPECIAL INSPECTION IS REQUIRED FOR WOOD SHEAR WALLS, SHEAR PANELS, AND DIAPHRAGMS, INCLUDING NAILING, BOLTING, ANCHORING, AND OTHER FASTENING TO COMPONENTS OF THE SEISMIC FORCE RESISTING SYSTEM. SPECIAL INSPECTION BY A DEPUTY INSPECTOR IS REQUIRED WHERE THE FASTENER SPACING OF THE SHEATHING IS 4 INCHES ON CENTER OR LESS. (1707.5.12.2) 10.SPECIAL ACTIVITY INSPECTION IS REQUIRED FOR (BUILDINGS OVER 5 STORIES OR 60' IN HEIGHT) (BUILDINGS OVER 50,000 SQ. FT. OF GROUND FLOOR AREA) (BUILDING OVER 200,000 SQ. FT. OF TOTAL FLOOR AREA.) (1705.1.6) 11.A COPY OF THE LOS ANGELES RESEARCH REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE AVAILABLE AT THE JOB SITE. FOUNDATIONS AND GRADING 1.IF ADVERSE SOIL CONDITIONS ARE ENCOUNTERED, A SOILS INVESTIGATION REPORT MAY BE REQUIRED. SHEAR WALLS 1. HOLD-DOWN CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE APPROVED PLATE WASHERS; AND HOLD-DOWNS SHALL BE FINGER TIGHT AND ½ WRENCH TURN JUST PRIOR TO COVERING THE WALL FRAMING. CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE STEEL PLATE WASHERS ON THE POST ON THE OPPOSITE SIDE OF THE ANCHORAGE DEVICE. PLATE SIZE SHALL BE A MINIMUM OF 0.299 INCH BY 3 INCHES BY 3 INCHES. (2305.5) 2. ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING". FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. FLOOR SHALL HAVE TONGUE AND GROOVE OR BLOCKED PANEL EDGES. PLYWOOD SPANS SHALL CONFORM WITH TABLE 2304.8(1). 3.ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED BOX. 4. ALL BOLT HOLES SHALL BE DRILLED 1/32 TO 1/16" OVERSIZED. (NDS 12.1.3.2) 5.HOLD-DOWN HARDWARE MUST BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION. S-0.14 ST R U C T U R A L N O T E S GEGAM BURNAZYAN MLB CONSULTING AND ENGINEERING SHALL BE ENGINEER OF RECORD ADU S0.20 TY P . W O O D F R A M I N G D E T A I L S , DI A P H R A G M , S H E A R W A L L N A I L I N G AN D S C H E D U L E SHEARWALL SCHEDULE TYPE SHEATHING THICKNESS MIN. BOT. SILL PL. , STUD, BLK'G. @ ADJOINING PANEL EDGES EDGE NAILING (E.N.)FIELD NAILING SIMPSON 'A35' OR 'LTP4' SPACING SILL PL. ATTACHMENT ANCHOR BOLTS RESISTANCE (PLF) (ɸVn) OPTION A: SIMPSON 'SDS' LAG SCREW OPTION B: 16d NAILS 2x BOT. SILL PL.3x BOT. SILL PL. A 15/32" EXP. 1 STRUCTURAL 1 2X 8d @ 6" O.C.12" O.C.22" O.C.14" O.C.8" O.C.5/8" Ø x 10" LONG @ 48" O.C. 5/8" Ø x 12" LONG @ 48" O.C.440 B 15/32" EXP. 1 STRUCTURAL 1 2X 10d @ 6" O.C.12" O.C.18" O.C.11" O.C.6" O.C.5/8" Ø x 10" LONG @ 48" O.C. 5/8" Ø x 12" LONG @ 48" O.C.540 C 15/32" EXP. 1 STRUCTURAL 1 3X 10d @ 4" O.C.12" O.C.12" O.C.7" O.C.4" O.C.N.A.5/8" Ø x 12" LONG @ 32" O.C.810 D 15/32" EXP. 1 STRUCTURAL 1 3X 10d @ 3" O.C.12" O.C.9" O.C.5" O.C.3" O.C.N.A.5/8" Ø x 12" LONG @ 25" O.C.1060 E 15/32" EXP. 1 STRUCTURAL 1 3X 10d @ 2" O.C.12" O.C.7" O.C.4" O.C.2" O.C.N.A.5/8" Ø x 12" LONG @ 19" O.C.1390 F 15/32" EXP. 1 STRUCTURAL 1 BOTH SIDES 3X 10d @ 3" O.C.12" O.C.4" O.C.3" O.C.N.A.N.A.5/8" Ø x 12" LONG @ 12" O.C.2100 G 15/32" EXP. 1 STRUCTURAL 1 BOTH SIDES 3X 10d @ 2" O.C.12" O.C.3" O.C.2" O.C.N.A.N.A.5/8" Ø x 12" LONG @ 11" O.C.2750 SHEAR WALL SCHEDULE NOTES: 1. LUMBER SHALL BE DF-L W/ SPECIFIC GRAVITY OF 0.50 MIN. 2. ALL PANEL EDGES SHALL BE FASTENED TO 2-INCH NOMINAL OR WIDER FRAMING 3. FRAMING MEMBERS RECEIVING EDGE NAILING FROM ABUTTING PANELS SHALL NOT BE LESS THAN A SINGLE 3x STUD OR WIDER NOMINAL. 4. ALL WOOD STRUCTURAL PANEL JOINTS AND SILL PLATE NAILING SHALL BE STAGGERED AT ALL PANEL EDGES. 5. NAILS SHALL BE PLACED AT LEAST 1/2" FROM PANEL EDGES AND 3/8" FROM THE EDGE OF THE CONNECTING MEMBERS. 6. PROVIDE A MINIMUM OF TWO ANCHOR BOLTS PER SHEARWALL. SEE DETAIL 6 / S0.21 FOR EDGE AND END DISTANCES. 7. SPACING FOR 'A35' & 'LPT4' MAY BE REDUCED MAX. 16" O.C. IF ADDITIONAL 'A35' & 'LTP4' ARE INSTALLED ALONG SAME SHEARWALL LINE TO MEET MIN. QTY. REQUIRED FOR THE IDENTIFIED SPACING MULTIPLIED BY SHEARWALL LENGTH. ALSO, SPACING OF 'A35' & 'LTP4' MAY BE DOUBLED IF PLACED ON BOTH SIDES OF THE SHEARWALL. 8. ALL NAILS SHALL BE COMMON NAILS, U.O.N. 9. E.N. = EDGE NAILING 10. F.N. - FIELD NAILING 11. ALL PANEL EDGES SHALL BE FRAMED W/ 2" NOMINAL OR WIDER BACKING (BLOCKING OR STUD) U.O.N. 12. PANELS CAN BE INSTALLED HORIZONTALLY OR VERTICALLY. 13. ALL ANCHOR BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 7" INTO CONCRETE, U.O.N. 14. ALL SHEARWALLS SHALL EXTEND FROM SILL PLATE TO FLOOR/ROOF DIAPHRAGM SEHATHING 15. MINIMUM 3"x3x0.299" WASHER PLATE REQUIRED UNDER ANCHOR BOLT NUTS AT ALL SHEARWALLS. 16. ALL OTHER "SHEARWALL" NOTES WRITTEN IN THE STANDARD NOTE SHEETS SHALL APPLY. 17. DEPUTY INSPECTION REQ'D FOR TYPES C,D,E,F, & G DATE:11/14/2024 JOB NO: MLB24-1210 DESIGNED BY: HK CHECKED BY: GB DE S C R I P T I O N DA T E RE V BY 1 3 4 5 - 2 - - MLB CONSULTING AND ENGINEERING, INC 7918 FOOTHILL BLVD SUNLAND, CA 91040 (818) 521-6342 INFO@MLBENGINEERING.ORG 4703 W McFadden Ave Santa Ana, CA 92704 EDGE NAILING (E.N.) STAGGER 2x OR 3x BLK'G. PER SHEARWALL SCHEDULE ON HORIZ. PANEL JOINTS EDGE NAILING (E.N.) FIELD NAILING (F.N.) STUD @ 16" O.C. (MIN.) (U.O.N. ON PLAN & DETAILS) SILL PL. (ANCHORS PER SHEAR WALL SCHEDULE) HOLDOWN PER PLAN DOUBLE TOP PL.'S 2x OR 3x PANEL JOISTS (PER SHEARWALL SCHED.) TO BE CENTERED ON STUDS) SHEARWALL PANEL PER SHEAR WALL SCHEDULE STAGGER HORIZ. PANEL JOINTS 2x OR 3x SILL PL. PER SHEARWALL SCHEDULE NOTES: 1. MIN. NAIL EDGE DISTANCE SHALL BE 3/8" FROM PANEL EDGES FOR 2x's & 1/2" FOR 3x's 2. MIN. SIZE OF SHEATHING SHALL BE 24" x 24" 1 N.T.S SHEAR PANEL ELEV. (ONE SIDE 4" & 6" O.C. E.N.) EDGE NAILING (E.N.) STAGGER 3x BLK'G CENTER ON HORIZ. PANEL JOINTS STAGGER ALL EDGE NAILING (E.N.) FIELD NAILING (F.N.) STUD @ 16" O.C. (MIN.) (U.O.N. ON PLAN & DETAILS) SILL PL. (ANCHORS PER SHEAR WALL SCHEDULE) HOLDOWN PER PLAN DOUBLE TOP PL.'S 3x STUD @ PANEL JOINTS. PLYWOOD JOINTS TO BE CENTERED ON STUDS ON SHEARWALL PANEL PER SHEARWALL SCHEDULE STAGGER HORIZ. PANEL JOINTS 3x SILL PL. NOTES: 1. MIN. NAIL EDGE DISTANCE SHALL BE 3/8" FROM PANEL EDGES 2. MIN. SIZE OF SHEATHING SHALL BE 24" x 24" 2 N.T.S SHEAR PANEL ELEV. (DENSE NAILING 2" & 3" O.C. E.N.) 3 N.T.S SHEAR PANEL ELEV. (BOTH SIDES) EDGE NAILING (E.N.) STAGGER 3x BLK'G CENTER ON HORIZ. PANEL JOINTS STAGGER ALL EDGE NAILING (E.N.) FIELD NAILING (F.N.) STUD @ 16" O.C. (MIN.) (U.O.N. ON PLAN & DETAILS) SILL PL. (ANCHORS PER SHEAR WALL SCHEDULE) HOLDOWN PER PLAN DOUBLE TOP PL.'S 3x STUD @ PANEL JOINTS. PLYWOOD JOINTS TO BE CENTERED ON STUDS (JOINT ON ONE SIDE OF FRAMING MUST BE OFFSET FROM THOSE ON OTHER SIDE) SHEARWALL PANEL BOTH SIDES STAGGER HORIZ. PANEL JOINTS 3x SILL PL. NOTES: 1. MIN. NAIL EDGE DISTANCE SHALL BE 3/8" FROM PANEL EDGES 2. MIN. SIZE OF SHEATHING SHALL BE 24" x 24" 4 PLYWOOD SHEARWALL SCHEDULE N.T.S -L =HEADER PER PLAN -- STRAP / HD CALL-OUT. TYP. SHEARWALL @ LEVEL ABV. SHEARWALL @ LEVEL BELOW SHEARWALL TYPE PER SCHED. MIN. SHEARWALL LENGTH SHEARWALL LEGEND ON PLANS DRAG STRAP PER PLAN 5 N.T.S 3- 1 / 2 " 3/ 4 " 3/ 4 " 1/ 2 " M I N . 1/ 2 " M I N . FASTENER SPACING 4" NOMINAL - TWO LINES OF FASTENERS 3- 1 / 2 " ADJOINING PANEL EGDE 4" NOMINAL - THREE LINES OF FASTENERS ADJOINING PANEL EGDE 3/ 8 " M I N . 3/ 8 " M I N . 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " HIGH LOAD DIAPHRAGM SHEATHING 5/8" MIN. EA. SIDE 2.2" MAX. 1.375" MAX. 2x6 & 3x6 STUDS 5/8" MIN. EA. SIDE 1.4" 7/8" MAX. 2x4 & 3x4 STUDS EXTERIOR OR BEARING WALLS NON-BEARING WALLS 5/8" MIN. EA. SIDE 3.3" MAX. 2.2" MAX. 2x6 & 3x6 STUDS 5/8" MIN. EA. SIDE 1.4" MAX. 2x4 & 3x4 STUDS 2.1" 3 1/2"5 1/2"3 1/2"5 1/2" 6 N.T.S WOOD STUD NOTCHES DIAPHRAGM BOUNDARY 4'X8' PLYWOOD PANEL BOUNDARY NAILING PANEL EDGE NAILING IF BLOCKING REQ'D. SEE ROOF FRAMING PLAN FIELD NAILING BLOCKING AT PANEL EDGES IF REQUIRED. SEE ROOF FRAMING PLAN. IF BLOCKING IS NOT NOTED ON ROOF FRAMING PLAN THEN NOT REQUIRED. JOISTS (FLOOR OR ROOF) LOCATION SHEATHING & NAILING ROOF 15 32" BLOCKED OSB SHEATHING PANEL 10d @ 6" BOUNDARIES,10d @ 6" EDGES,10d @ 12" INTERIORS FLOOR 3 4" T & G PLYWOOD SHEATHING OR SLAB ON GRADE PER PLAN. 10d @ 6" BOUNDARIES,10d @ 6" EDGES,10d @ 12" INTERIORS 7 ROOF AND FLOOR DIAPHRAGM DETAIL AND SCHEDULE N.T.S E.N. HOLD-DOWN POST PER PLAN 16d @ 4" O.C. VERTICALLY SHEAR PANEL PER PLAN HOLD-DOWN PER PLAN. (WHERE OCCURS) 16d @ 4" O.C. VERTICALLY 4x OR 6x POST PER PLAN STRAP PER PLAN (WHERE OCCURS) 16d @ 4" O.C. VERTICALLY SHEAR PANEL PER PLAN E.N. E.N. E.N. 4x OR 6x POST PER PLAN STRAP PER PLAN (WHERE OCCURS) 16d @ 4" O.C. VERTICALLY E.N. SHEAR PANEL PER PLAN SHEAR PANEL PER PLAN HOLD-DOWN PER PLAN. (WHERE OCCURS) E.N. E.N.E.N. HOLD-DOWN PER PLAN (WHERE OCCURS) STRAP PER PLAN (WHERE OCCURS) 4x OR 6x POST PER PLAN SHEAR PANEL PER PLAN SHEAR PANEL PER PLAN E.N. E.N. HOLD-DOWN PER PLAN (WHERE OCCURS) 4x OR 6x POST PER PLAN SHEAR PANEL PER PLAN STRAP PER PLAN (WHERE OCCURS) SHEAR PANEL PER PLAN E.N. HOLD-DOWN PER PLAN (WHERE OCCURS) SHEAR PANEL PER PLAN 4x OR 6x POST PER PLAN STRAP PER PLAN (WHERE OCCURS) NOTES: 1. SHEARWALL w/ TIGHTEST NAILING PATTERN SHALL EXTEND OVER HOLD-DOWN POST A - SHEAR TRANSFER AT CORNER W/ HOLDOWN B - SHEAR TRANSFER AT CORNER W/ STRAP C - SHEAR TRANSFER AT CORNER W/ STRAP & HD D - SHEAR TRANSFER AT WALL INTERSECTION E.N. SHEAR PANEL PER PLAN HOLD-DOWN PER PLAN (WHERE OCCURS) HOLD-DOWN PER PLAN (WHERE OCCURS) 4x OR 6x POST PER PLAN STRAP PER PLAN (WHERE OCCURS) E - SHEAR TRANSFER AT T-INTERSECTION F - SHEAR TRANSFER AT CORNER W/ STRAP & HD G - SHEAR TRANSFER AT WALL END W/ STRAP & HD 5 N.T.S UPDATE THIS DESCRIPTION 7" E M B E D . MI N . 24" MIN.12" E.N.E.N. 2x TRIMMERS OR 4x POST 4x MIN. POST PER PLAN @ HOLDOWN LOCATION. HD PER PLAN HEADER PER PLAN 60" SIMPSON 'CS16' STRAP E. N . E. N . HD BOLT PER SCHEDULE CONT. TOP PLATES. SEE DETAIL 1/S-0.2 FOR SPLICE REQUIREMENTS 4x MIN. POST PER PLAN @ HOLDOWN LOCATION 2'-0" MIN. 3x4 MIN. FLAT BLKG. @ ALL PANEL JOINTS A35 EA. SIDE 2' - 0 " M I N . F. N . F. N . SEE PLANS FOR SHEARWALL LENGTH F. N . F. N . E.N.E.N. E.N.E.N. E. N . E. N . E. N . E. N . SIMPSON "CS16" WRAPPED AROUND SILL PL. @ PIPE OPENING E.N.E.N. 9"6"9" PLYWOOD SHEATHING ROOF DRAIN PIPE WHERE OCCURS E.N. A.B. EA. SIDE OF PIPE HOLDOWN POST PER PLAN SIMPSON "CS16" WRAPPED AROUND SILL PL. PLAN VIEW @ DRAIN PIPE DATE:11/14/2024 JOB NO: MLB24-1210 DESIGNED BY: HK CHECKED BY: GB DE S C R I P T I O N DA T E RE V BY 1 3 4 5 - 2 - - MLB CONSULTING AND ENGINEERING, INC 7918 FOOTHILL BLVD SUNLAND, CA 91040 (818) 521-6342 INFO@MLBENGINEERING.ORG 4703 W McFadden Ave Santa Ana, CA 92704 TYP. MINIMUM ROOF HEADER SCHEDULE (U.O.N. ON PLANS) WIDTH OF OPENING NUMBER OF TRIMMERS HEADER SIZE 2x4 Wall Framing 2x6 Framing up to 4'-0"1 4x4 6x6 up to 6'-0"1 4x6 6x6 up to 8'-0"2 4x8 6x8 up to 10'-0"2 4x10 6x12 up to 12'-0"3 4x12 6x12 TYP. MINIMUM FLOOR & ROOF DECK HEADER SCHEDULE (U.O.N. ON PLANS) WIDTH OF OPENING NUMBER OF TRIMMERS HEADER SIZE 2x4 Wall Framing 2x6 Framing up to 4'-0"2 4x4 6x6 up to 6'-0"2 4x6 6x6 up to 8'-0"2 4x8 6x8 up to 10'-0"2 4x10 6x12 up to 12'-0"3 4x12 6x12 STUD WALL PER PLAN (6) - 16d NAILS EA. SIDE OF SPLICE. TYP.SILL PL. SPLICE "A""B" NOTES: USE THIS DETAIL WHEN EITHER "A" OR "B" IS GREATER THAN 1'-0" ANCHOR BOLT PER SW SCHED. TYP. NOTES: 1. USE 5/8" Ø ANCHOR BOLTS PER SCHEDULE ON DETAIL X / S0.XX 2. EACH SILL PLATE PIECE SHALL HAVE (2) BOLTS MINIMUM. HOLD-DOWN ANCHORS ARE NOT CONSIDERED AN ANCHOR BOLT. 3. LOCATE BOLTS WITHIN 9" OF SILL PLATE ENDS AND AT 4'-0" O.C. MAX. 4. USE PLATE WASHER PER SHEARWALL SCHEDULE AT EA. BOLT. STANDARD CUT WASHERS ARE ACCEPTABLE AT NON-SHEAR WALLS. 5. DO NOT DRILL OVERSIZE HOLES THRU SILL PLATE. UISE 11/16" Ø DRILL BIT. 6. SILL PLATE THICKNESS AND FASTENING AT SHEARWALLS PER SHEAR WALL SCHEDULE ON DETAIL X/S0.XX 7. CONTACT THE ENGINEER-OF-RECORD FOR POST-INSTALLED ANCHOR OPTIONS. 9" MAX. 4 1/2" MIN. 4 1 / 2 " M I N . 9" M A X . 4 1/2" MIN. 9" MAX. 4 1/2" MIN. 9" MAX. 4 1/2" MIN. 9" MAX. 4 1/2" MIN. 9" MAX. NOTCH IN SILL PL. PER DETAIL 2 PLYWOOD SHEATHING PER PLAN DRAG STRAP PER PLAN SIMPSON 'ECCQ' FLOOR BEAM PER PLAN OVER TOP PL'S. WOOD POST PER PLAN STUD WALL FRAMING PER PLAN CRIPPLE WALL FRAMING DOUBLE TOP PL'S. WINDOW OPENINING NON-LOAD BEARING HEADER SIZES PER SCHEDULE DOUBLE TRIMMER 2 TYPICAL HEADER CONSTRUCTION WITH BEAM ABOVE N.T.S DBL. TOP PL. (2) ROWS - 0.148"Ø x 3.25" NAILS (16 - TOTAL). STAGGERED WITHIN AREA OF SPLICE @ 6" O.C. PLATE SPLICE TO OCCUR OVER STUDS, TYP. STUD WALL PER PLAN 4'-0" MIN. SPLICE LAP NOTES: 1. USE 5/8" Ø ANCHOR BOLTS PER SCHEDULE ON DETAIL X / S0.XX 2. EACH SILL PLATE PIECE SHALL HAVE (2) BOLTS MINIMUM. HOLD-DOWN ANCHORS ARE NOT CONSIDERED AN ANCHOR BOLT. 3. LOCATE BOLTS WITHIN 9" OF SILL PLATE ENDS AND AT 4'-0" O.C. MAX. 4. USE PLATE WASHER PER SHEARWALL SCHEDULE AT EA. BOLT. STANDARD CUT WASHERS ARE ACCEPTABLE AT NON-SHEAR WALLS. 5. DO NOT DRILL OVERSIZE HOLES THRU SILL PLATE. UISE 11/16" Ø DRILL BIT. 6. SILL PLATE THICKNESS AND FASTENING AT SHEARWALLS PER SHEAR WALL SCHEDULE ON DETAIL X/S0.XX 7. CONTACT THE ENGINEER-OF-RECORD FOR POST-INSTALLED ANCHOR OPTIONS. 5 TYP. PLATE SPLICE DETAIL N.T.S4SILL PLATE SPLICE N.T.S 1 PLYWOOD SHEARWALL ELEVATION DETAIL N.T.S 6 TYP. SILL PLATE BOLTING N.T.S S0.21 TY P . W O O D F R A M I N G D E T A I L S WA L L C O N S T R U C T I O N SILL END DATE:11/14/2024 JOB NO: MLB24-1210 DESIGNED BY: HK CHECKED BY: GB DE S C R I P T I O N DA T E RE V BY 1 3 4 5 - 2 - - MLB CONSULTING AND ENGINEERING, INC 7918 FOOTHILL BLVD SUNLAND, CA 91040 (818) 521-6342 INFO@MLBENGINEERING.ORG 4703 W McFadden Ave Santa Ana, CA 92704 HOLDOWN @ INTERIOR FOUNDATION SHEAR TRANSFER @ EXTERIOR FOUNDATION HOLDOWN @ EXTERIOR FOUNDATION GIRDER POST 6"MIN 18 " M I N . PER HOLDOWN SCHEDULE NOTE: FOOTING DETAILS NOT IDENTIFIED. SEE DETAIL 2 THIS SHEET FOR FOOTING DETAILS. EM B E D . PE R S C H E D NOTE: (TABLE BELOW) 1-LOAD AND RESISTANCE FACTOR DESIGN. 2-MINIMUM END DISTANCE SHALL BE 5". 5-POST MAXIMUM HEIGHT OF 10.0 ft. PER PLAN PER PLAN 18 " 3" C O V E R (T Y P . ) 6" MI N 24 " PER PLAN 1' - 6 " 6" MIN NOTE: FOOTING DETAILS NOT IDENTIFIED. SEE DETAIL 5 THIS SHEET FOR FOOTING DETAILS. NOTE: (TABLE BELOW) 1-LOAD AND RESISTANCE FACTOR DESIGN. 2-MINIMUM END DISTANCE SHALL BE 5". 5-POST MAXIMUM HEIGHT OF 10.0 ft. EM B E D . PE R S C H E D 1' 3" M I N . CO V E R 6"MIN . 1' - 6 " M I N . I N T O AP P R O V E D S O I L PER PLAN E.N. F.N.F.N. E.N. E.N. F.N. F.N.F.N. S-0.31 FO U N D A T I O N D E T A I L S 1 2 4 TYP. STAIRS ON GRADE 5 6 7 -8 9 PER PLAN 24 " 3" C O V E R (T Y P . ) 2" M I N PER PLAN 3" C O V E R (T Y P . ) 6" MI N 18 " M I N INTERIOR PAD FOOTING 24 " M I N I N T O AP P R O V E D S O I L 24 " M I N I N T O AP P R O V E D S O I L E.N. E.N.F.N.F.N. SCALE:1"=1'-0"SCALE:1"=1'-0"SCALE:1"=1'-0" SCALE:1"=1'-0"SCALE:1"=1'-0"SCALE:1"=1'-0" SCALE:1"=1'-0"SCALE:1"=1'-0" #4 NOSING BAR (1-1/2" COVER TYP.) #4 @ 16" O.C. EA. WAY (2) -#4 BOT. BARS POST PER PLAN L.C.B. COLUMN BASE HARDSCAPE PER ARCH REINF. PER PLAN SEE S-1 SHEET SDS LAG / NAILING PER SHEAR WALL SCHED. PLYWOOD SHEATHING PER PLAN SIMPSON A35 PER S.W. SCHED JOIST PER PLAN (2) -#4 TOP BARS ANCHOR BOLT PER S.W. SCHED. SHEAR WALL PER PLAN 2x BLKING #4 @ 24" O.C. (2) -#4 BOT. BARS SSTB ANCHOR BOLT PER SCHED. COUPLER AS NECESSARY FULL WIDTH BLKING @ H.D. HOLDOWN PER PLAN PLYWOOD SHEATHING PER PLAN 3x P.T. SILL SSTB ANCHOR BOLT PER SCHED. COUPLER AS NECESSARY FULL WIDTH BLKING @ H.D. HOLDOWN PER PLAN PLYWOOD SHEATHING PER PLAN GIRDER PER PLAN PC CAP P.T. 4x4 POST LCB COLUMN BASE JOIST PER PLAN 2x BLKING A35 @ 32" O.C. PLYWOOD SHEATHING PER PLAN (3) -#4 BARS EA. WAY ADD JOIST OR BLKING @ POST PENETRATION ON 4 SIDES (TYP.)PLYWOOD SHEATHING PER PLAN JOIST PER PLAN P.T. 4x4 POST SIMPSON CB-COLUMN BASE REINF. PER PLAN 2x JOIST BLKING @ 48" O.C. 3 SCALE:1"=1'-0" NEW FOOTING CONNECTION TO EXISTING RAISED FOUNDATION THREADED ROD PER SCHED. 5" MIN. EMBEMENT SIMPSON SET-3G EPOXY DEPUTY INSPECTION REQ'D. 2x BLKG. W/ SHEAR CLIPS PER SCHED. 3/S0.2 (E) SILL - EPOXY SILL BOLTS PER SCHED. 3/S0.2 JOISTS PER PLAN (E) SHEATHING SILL PLATE & LAGS PER SCHED. 3/S0.2 SHEAR WALL PER PLAN MIN. EDGE DIST. PER SCHED. B.N. (E) STEM WALL FOOTING 6" MIN VERIFY 12" MIN VERIFY IN FIELD B.N. THREADED ROD PER SCHED. EMBEDMENT PER SCHED. SIMPSON SET-3G EPOXY VERIFY STEM WALL WIDTH DEPUTY INSPECTION REQ'D. (SEE SCHEDULE) FULL WIDTH BLOCKING (E) SILL JOISTS PER PLAN (E) SHEATHING SILL PLATE HD PER PLAN 2 3 4" MIN 6" MIN VERIFY EM B E D M E N T NOTE: (ON TABLE BELOW) 1-LOAD AND RESISTANCE FACTOR DESIGN. 4-OVERALL CONCRETE FOOTING DEPTH SHALL BE 5D DEEPER THAN ANCHOR EMBEDMENT. 5-POST MAXIMUM HEIGHT OF 10.0 ft. 18 " M I N 12 " M I N POST PER PLAN 8" 12" EX FOOTING NEW FOOTING REBAR DOWELS TO MATCH # AND SIZE OF NEW FOOTING SIMPSON SET-3G ESR 4057 3" M I N THREADED ROD PER SCHED. 5" MIN. EMBEMENT SIMPSON SET-3G EPOXY DEPUTY INSPECTION REQ'D. 2x BLKG. W/ SHEAR CLIPS PER SCHED. 3/S0.2 (E) SILL - EPOXY SILL BOLTS PER SCHED. 3/S0.2 JOISTS PER PLAN (E) SHEATHING 1.75" B.N. (E) FOOTING 6" MIN VERIFY 12" MIN VERIFY IN FIELD 18 " M I N B.N. RAISED AT EX FOOTING 24 " I N T O A P P R O V . SO I L PER PLAN 1' - 6 " 6" MIN 3" C L R E.N.F.N.F.N. SDS LAG / NAILING PER SHEAR WALL SCHED. PLYWOOD SHEATHING PER PLAN 2x JOIST BLKING @ 48" O.C. JOIST PER PLAN 3x P.T. SILL W/ ANCHOR BOLT PER S.W. SCHED. #4 @ 24" O.C. FOOTING PER PLAN (2) -#4 BOT. BARS 10 SCALE:1"=1'-0" SHEAR TRANSFER @ INTERIOR FOUNDATION 11 SCALE:1"=1'-0"12 SCALE:1"=1'-0" PAD FOOTING DATE:11/14/2024 JOB NO: MLB24-1210 DESIGNED BY: HK CHECKED BY: GB DE S C R I P T I O N DA T E RE V BY 1 3 4 5 - 2 - - MLB CONSULTING AND ENGINEERING, INC 7918 FOOTHILL BLVD SUNLAND, CA 91040 (818) 521-6342 INFO@MLBENGINEERING.ORG 4703 W McFadden Ave Santa Ana, CA 92704 S-0.51 RO O F F R A M I N G D E T A I L S E.N. E.N. A35 PER S.W. SCHED. JOIST PER PLAN RAFTER PER PLAN 2x BLKING PLYWOOD SHEATHING PER PLAN SHEAR WALL PER PLAN DBL TOP PLATES (5) -10d NAILS @ EA. LAP 1 SCALE:1"=1'-0" TYPICAL SHEAR TRANSFER 4 SCALE:1"=1'-0" TYPICAL SHEAR TRANSFER 2 SCALE:1"=1'-0" E.N. E.N. A35 PER S.W. SCHED. RAFTER PER PLAN 2x BLKING PLYWOOD SHEATHING PER PLAN SHEAR WALL PER PLAN DBL TOP PLATES TYPICAL SHEAR TRANSFER STRAP OVER HIP/RIDGE PLYWOOD SHEATHING PER PLAN HIP/VALLEY BOARD PER PLAN RAFTER PER PLAN SIMPSON U-HANGER (N) 2X4 @ 16" OC CRIPPLE WALL AND DOUBLE TOP PLATES CONT. UNDER HIP C.J. PER PLAN 2x BLKG. STRAP OVER HIP/RIDGE PLYWOOD SHEATHING PER PLAN HIP/VALLEY BOARD PER PLAN RAFTER PER PLAN SIMPSON U-HANGER 2x SLEEPER MST 48 @ 48" O.C. RAFTER PER PLAN PLYWOOD SHEATHING PER PLAN STRAP OVER HIP/RIDGE PLYWOOD SHEATHING PER PLAN HIP/VALLEY PER PLAN RAFTER PER PLAN SIMPSON U-HANGER (N) 2X4 @ 16" OC CRIPPLE WALL AND DOUBLE TOP PLATES CONT. UNDER HIP C.J. PER PLAN 2x BLKG. 3 SCALE:1"=1'-0" 5 SCALE:1"=1'-0"6 SCALE:1"=1'-0"7 SCALE:1"=1'-0" TYPICAL SHEAR TRANSFER 8 SCALE:1"=1'-0" TYPICAL SHEAR TRANSFER 9 SCALE:1"=1'-0"10 SCALE:1"=1'-0"11 SCALE:1"=1'-0" TYPICAL SHEAR TRANSFER E.N.E.N. E.N.E.N. SIMPSON U-HANGER ST22 @ 32" O.C. PLYWOOD SHEATHING PER PLAN RAFTER PER PLAN BEAM PER PLAN MIN (3)- 16d TOE NAILS @ EA. RAFTER RAFTER PER PLAN RIDGE BOARD PER PLAN ST22 @ 32" O.C.PLYWOOD SHEATHING PER PLAN JOIST WHERE THEY OCCUR F.N. F.N. E.N. F.N.F.N.F.N. 2x JOIST BLKING @ 48" O.C.PLYWOOD SHEATHING PER PLAN RAFTER PER PLAN SIMPSON A35 PER S.W. SCHED RAFTER PER PLAN NOTCH RAFTER AS NEEDED TO FIT 2x SILL 2X SILL W/ SDS LAGS PER S.W. SCHED CONT. SHEATHING PER PLAN SIMPSON LTP4 PER S.W. SCHED JOIST PER PLAN (5) -10d NAILS @ EA. LAP SHEAR WALL PER PLAN END JOIST W/(3)-16d NAILS @ 32" O.C. E.N. E.N. SIMPSON U-HANGER ST22 @ 32" O.C. PLYWOOD SHEATHING PER PLAN RAFTER PER PLAN RIDGE PER PLAN SIMPSON LTP4 @ 16" OC (N) 2X4 @ 16" OC CRIPPLE WALL AND DOUBLE TOP PLATES CONT. UNDER HIP JOISTS PER PLAN 2x BLKING TYPICAL SHEAR TRANSFER HIP BOARD PER PLAN SIMPSON HRC22 W/ CUSTOM CUT TO MATCH ROOF SLOPE RIDGE BOARD PER PLAN HIP BEAM SIMPSON HCP DOUBLE PLATE POST PER PLAN WHERE OCUURS TYPICAL SHEAR TRANSFER RIDGE BOARD PER PLAN HIP BOARD PER PLAN VALLEY BOARD PER PLAN SIMPSON HHRC W/ CUSTOM CUT TO MATCH ROOF SLOPE TYPICAL SHEAR TRANSFER TYPICAL SHEAR TRANSFER SHEAR WALL PER PLAN 6X6 DF-L NO.2 COLUMN DOUBLE TOP PLATES ROOF RAFTERS PER PLAN CMST14 STRAPFLOOR SHEATHING PER S-0.2 ROOF RAFTERS PER PLAN 2X BLOCKING BEYOND A35@ 16" OC TYPICAL SHEAR TRANSFER A35 PER S.W. SCHED. DATE:11/14/2024 JOB NO: MLB24-1210 DESIGNED BY: HK CHECKED BY: GB DE S C R I P T I O N DA T E RE V BY 1 3 4 5 - 2 - - MLB CONSULTING AND ENGINEERING, INC 7918 FOOTHILL BLVD SUNLAND, CA 91040 (818) 521-6342 INFO@MLBENGINEERING.ORG 4703 W McFadden Ave Santa Ana, CA 92704 Scale: 1/4" = 1' FOUNDATION PLAN -A S-1 FO U N D A T I O N P L A N LEGEND POST ABOVE - HOLDOWN TRANSFER AT: - EXTERIOR (N) RAISED FND SEE DETAIL 2/S0.31 - INTERIOR (EX) RAISED SEE DETAIL 7/S0.31 (N) 2X STUD WALL CONC. SPREAD FTG. SIZE & REINF. PER PLAN EX 2X STUD WALL CONC. SPREAD FTG. SIZE & REINF. PER PLAN EX RAISED FOUNDATION 12 " M I N E X F T G V . I . F . 1' 1' 1'1'1' - 6 " 1'-6" 1' 2X 6 D F - L N o . 2 FJ @ 1 6 " O . C . 2X 6 D F - L N o . 2 FJ @ 1 6 " O . C . 4X6 DF-L No.2 FG 4X6 DF-L No.2 FG 4X6 DF-L No.2 FG 4X6 DF-L No.2 FG 4X6 DF-L No.2 FG 4X6 DF-L No.2 FG 4X6 DF-L No.2 FG 4X6 DF-L No.2 FG 1 S0.31 1 S0.31 1 S0.31 1 S0.31 1 S0.31 9 S-0.31 6 S0.31 12 S-0.31 12 S-0.31 2 S-0.31 2 S-0.31 2 S-0.31 2 S-0.31 2 S-0.31 2 S-0.31 2 S-0.31 2 S-0.312 S-0.31 2 S-0.31 2' 2' 8 S-0.31 DATE:11/14/2024 JOB NO: MLB24-1210 DESIGNED BY: HK CHECKED BY: GB DE S C R I P T I O N DA T E RE V BY 1 3 4 5 - 2 - - MLB CONSULTING AND ENGINEERING, INC 7918 FOOTHILL BLVD SUNLAND, CA 91040 (818) 521-6342 INFO@MLBENGINEERING.ORG 4703 W McFadden Ave Santa Ana, CA 92704 S-3 RO O F F R A M I N G P L A N LEGEND TYP. HEADER DEATIL -L =MIN. LENGTH OF SHEAR WALL S0.21 2 4x4 DF-L No.2 POST GENERAL NOTES 1. PRIOR TO START OF CONSTRUCTION, ALL DIMENSIONS AND ELEVATIONS MUST BE VERIFIED WITH THE APPROVED SET OF ARCHITECTURAL DRAWINGS. IN CASE OF DISCREPANCIES, THE ENGINEER OF RECORD MUST BE NOTIFIED IN WRITING. 2. PRIOR TO BIDDING, THE GENERAL CONTRACTOR MUST REVIEW THE STRUCTURAL PLANS THOROUGHLY FOR ALL THE INFORMATION NEEDED TO PROVIDE AN ACCURATE BID. IF THERE ARE ANY MISSING DETAILS OR INFORMATION THAT WOULD IMPACT THE COST OF THE PROJECT, THE GENERAL CONTRACTOR MUST NOTIFY THE ENGINEER OF RECORD IN WRITING FLOOR FRAMING NOTES: 1. FLOOR JOISTS/DECK JOISTS SHALL BE SPACED AT 16" O.C. UNLESS NOTED OTHERWISE ON PLANS. 2. LARGER COLUMN SHALL GOVERN WHEN SIZES CONFLICT BETWEEN HOLD DOWN SCHEDULE AND COLUMN SCHEDULE. 3. FOLLOWING WALLS SHALL BE CONSTRUCTED USING 2x6 DF-L NO. 2 @ 16" O.C. U.N.O. ON PLANS: - PLUMBING WALLS ONLY 4. ALL OTHER STUD WALLS SHALL BE CONSTRUCTED WITH 2x4 DF-L NO. 2 @ 16" O.C. U.N.O. ON PLANS AND NOT SPECIFICALLY IDENTIFIED IN NOTE 3 ABOVE. 5. IF ANY DISCREPANCIES IN MEMBER SIZES OCCUR, LARGER SIZE SHALL GOVERN. 6. ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. 7. NON LABELED HEADERS SHALL BE PER HEADER SCHEDULE ON SHEET S-0.21 U.N.O. ON PLANS. 8. CONTRACTOR SHALL PLACE DOUBLE FLOOR JOISTS WHERE NON-LOAD BEARING WALL STANDS ABOVE, WHERE APPLICABLE. 13. FOR ALL SIMPSON 'CMST' STRAPS REFER TO LA CITY RESEARCH REPORT NUMBER (ICC ESR #4057 SIMPSON SET -3G) 14. ALL SAWN LUMBER BEAMS SHALL BE MIN. DF-L NO.1 15. ROOF SHEATHING EVERYWHERE SHALL BE: 16. ALL FILL MATERIALS FOR STEEL BEAMS NEED TO BE DF-L NO.1 W/ MOISTURE CONTENT < 10% 17. HOLD-DOWN CONNECTOR BOLTS SHALL BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. FLOOR SHALL HAVE TONGUE AND GROOVE OR BLOCKED PANEL EDGES. PLYWOOD SPANS SHALL CONFORM WITH TABLE 2304.8(1). 18. ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED BOX. 19. ALL BOLT HOLES SHALL BE DRILLED 1 32" TO 1 16" OVERSIZED. 20. HOLD-DOWN HARDWARE MUST BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION. LATERAL LOAD RESISTING SYSTEM DESIGN (CONT.) SHEARWALL SCHEDULE Type Sheathing/ Nailing Grade A35/LTP4 Spacing (in)16d Nail Spacing (in)1/4" SDS LAG Spacing (in) 5/8" Anchor Bolt Spacing (in) Resistance (plf) Type A 15/32" w/8d nails @6-6-12 Structural I 22.0 8.0 14.0 48.0 440 Type B 15/32" w/10d nails @6-6-12 Structural I 18.0 6.0 11.0 48.0 540 Type C 15/32" w/10d nails @4-4-125 Structural I 12.0 4.0 7.0 32.0 810 Type D 15/32" w/10d nails @3-3-125 Structural I 9.0 3.0 5.0 25.0 1060 Type E 15/32" w/10d nails @2-2-125 Structural I 7.0 2.0 4.0 19.0 1390 Type F Double Sided 15/32" w/10d nails @3-3-124,5,8 Structural I 4.0 n/a 3.0 12.0 2100 Type G Double Sided 15/32" w/10d nails @2-2-124,5,8 Structural I 3.0 n/a 2.0 11.0 2750 Notes: 1. Lumber shall be DF-L with Specific Gravity of 0.50 min. All panel edges shall be fastened to 2-inch nominal or wider framing. 2. Framing members receiving edge nailing from abutting panels shall not be less than a single 3x stud or wider nominal. All wood structural panel joint and sill plate nailing shall be staggered at all panel edges. Nails shall be placed not less than 1/2" edge distance from the panel edges and 3/8" from the edge of the connecting members. 3. Min two bolts per piece of sill plate and one located within 12" of each end of each sill plate. Placement of lag bolts: Min edge distance shall be (1.5)(bolt diameter); Min end distance shall be (7)(bolt diameter), Min spacing shall be (4)(bolt diameter). Edge distances, end distances and spacing shall be sufficient to prevent splitting of wood. If splitting occurs, notify the engineer for an alternate product. 4. Type F and G shearwalls shall have plywood installed on both sides. Install A35/LTP4 staggered on both sides. Blocking and studs at panel edges shall be min 3x in thickness. 5. Type D, E, F, G shearwalls shall have min. 3x studs at panel edges. Special Inspection Required. 6. Plywood Panels may be either OSB, 3 ply, 4 ply or 5 ply plywood, unless specifically identified otherwise on plans. 7. For A35 and LTP4, use (12) 8dx1 1/2" nails. 8. Spacing for A35 and LTP4 may be reduced to max 16" oc if additional A35 and LTP4 are installed along same S/W line to meet the min qty required for the identified spacing multiplied by S/W length. Also, Spacing of A35 and LTP4 may be doubled if placed on both sides of shearwall. Scale: 1/4" = 1' ROOF FRAMING PLAN -A (N) 2X STUD WALLS STUD WALL CONSTRUCTION TABLE LEVEL WALL HEIGHT EXTERIOR INTERIOR LOAD BEARING INTERIOR PARTITION 4" WALL 6" WALL 1st Floor 8'-0"2x4 @ 16" O.C. 2x4 @ 16" O.C. 2x6 @ 16" O.C. 2x4 @ 16" O.C. NOTES: 1. ALL STUDS SHALL BE DF-L NO.2 2. SIZE INDICATED IS MINIMUM REQUIRED. CONTRACTOR SHALL VERIFY STUD SIZE WITH ENERGY CALCULATIONS (T24). LARGER SIZE SHALL GOVERN. 3. ALL NEW EXTERIOR WALLS SHALL BE SHEATHED WITH 1/2" THICK OSB OR PLYWOOD SHEATHING WHERE SHEARWALLS ARE NOT REQUIRED. * ENGINEER OF RECORD MAY REMOVE THIS REQUIREMENT UPON PROPERTY OWNER'S REQUEST AND WRITTEN APPROVAL FROM ENGINEER. 4. 3x STUDS MAY BE REQUIRED BASED ON SHEARWALL TYPE. SEE NOTES ON DETAIL 2/S-0.2 (EX) CJ (N) CJ (N) RR EX 2X STUD WALLS EX HDR EX HDR EX HDR EX HDR EX H D R EX H D R EX H D R EX H D R EX H D R EX HDR EX HDR EX HDREX HDREX HDR EX RR EX R R EX R R EX C J EX R R EX RR EX RR EX CJ EX H D R HDR 4X10 DF-L No.2 HD R 4 X 6 DF - L N o . 2 HD R 4 X 6 DF - L N o . 2 HDR 4X6 DF-L No.2 HDR 4X6 DF-L No.2 HDR 4X6 DF-L No.2 HDR 4X6 DF-L No.2 HDR 4X4 DF-L No.2 HDR 4X4 DF-L No.2 HD R 4 X 4 DF - L N o . 2 HD R 4 X 6 DF - L N o . 2 S-1.1 L=44'-0" A S-1.4 L=13'-9" A S-1.2 L=4'-8"A S-1.3 L=4'-9"A S-1.6 L = 3'-6"A S-1.5 L = 6'-0"A RR - 1 2 X 6 D F - L No . 2 @ 1 6 " O . C . RR - 1 2 X 6 D F - L No . 2 @ 1 6 " O . C . RR - 1 2 X 6 D F - L No . 2 @ 1 6 " O . C . RR-1 2X6 DF-L No.2 @16" O.C. RR-1 2X6 DF-L No.2 @16" O.C. RR-1 2X6 DF-L No.2 @16" O.C. RR-1 2X6 DF-L No.2 @16" O.C. HVB - 1 4 X 8 DF- L N o . 2 HRC-22 HRC-22 HVB - 1 4 X 8 DF- L N o . 2 HVB - 1 4 X 8 DF- L N o . 2 CJ - 1 2 X 8 D F - L No . 2 @ 1 6 " O . C . 4 S0.51 2 S0.51 2 S0.51 2 S0.51 2 S0.51 2 S0.51 2 S0.51 1 S0.51 3 S0.51 4 S0.51 1 S0.51 1 S0.51 6 S0.51 3 S0.51 5 S0.51 EX RR 4X4 DF-L No.2 BALLOON COLUMN W/ SIMPSON CCQ 4X4 DF-L No.2 BALLOON COLUMN W/ SIMPSON CCQ RB-1 4X8 DF-L No.2 RIDGE BOARD HVB - 1 4 X 8 DF- L N o . 2 HVB - 1 4 X 8 DF- L N o . 2 HVB - 1 4 X 8 DF- L N o . 2 2X4 DF-L No.2 CRIPPLE WALL @16" O.C. OVER CJ SUPPORTING RIDGE AND HIPS ABOVE RB-1 4X8 DF-L No.2 RIDGE BOARD CMST 14 STRAP CUT LENGTH 48" THROUGH DOUBLE TOP PLATES MST 48 SIMPSON STRAP RB - 2 4 X 8 DF - L N o . 2 RB - 2 4 X 8 DF - L N o . 2 EX H I P M I N 4 X 8 D F - L N o . 2 PLE A S E R E P L A C E I F CON D I T I O N S D O N ' T M E E T EX H I P M I N 4 X 8 D F - L N o . 2 PLE A S E R E P L A C E I F CON D I T I O N S D O N ' T M E E T S0.51 9 S0.51 8 S0.51 8 S0.51 9 S0.51 9 S0.51 9 S0.51 9 S0.51 11 7 S0.51 7 S0.51 2 S0.51 S0.51 8 S0.51 8 S0.51 10 S0.51 10 S0.51 8 10'- 6 " 58"10'- 6 5 / 8 " 10'- 6 5 / 8 " 10'- 6 " 58" NOTE: ALL NEW RIDGE, HIP, VALLEY MEMBERS ARE BEING SUPPORTED BY CJ-1 @ 16" O.C. S0.51 11 GSPublisherVersion 0.0.100.100 4 7 1 5 & 4 7 1 7 W . M C F A D D E N A V E , S A N T A A N A , CA 9 2 7 0 4 N E W A D D I T I O N T O N E W A D U sheet title: sheet number: REVISIONS NO.DATE DESCRIPTION DESIGN DRAWN ISSUED APPROVED NS JT T 1 .1 GREEN BUILDING SHEET N&NC 12 4 5 EA S T W A L N U T S T R E E T , ST E 11 2 PA S A D E N A , CA 91 1 0 6 CHAPTER 4 RESIDENTIAL MANDATORY MEASURES DIVISION 4.1 PLANNING AND DESIGN DIVISION 4.3 WATER EFFICIENCY AND CONSERVATION 4.406 ENHANCED DURABILITY AND REDUCED MAINTENANCE 4.406.1 RODENT PROOFING.Annular spaces around pipes ,electric cables ,conduits or other openings in sole/bottom plates at exterior walls shall be protected against the passage of rodents by closing such openings with cement mortar ,concrete masonry or a similar method acceptable to the enforcing agency . 4.408 CONSTRUCTION WASTE REDUCTION ,DISPOSAL AND RECYCLING 4.408.1 CONSTRUCTION WASTE MANAGEMENT .Recycle and /or salvage for reuse a minimum of 65 percent of the non -hazardous construction and demolition waste in accordance with either Section 4.408.2,4.408.3 or 4.408.4,or meet a more stringent local construction and demolition waste management ordinance . Exceptions: 1.Excavated soil and land -clearing debris . 2.Alternate waste reduction methods developed by working with local agencies if diversion or recycle facilities capable of compliance with this item do not exist or are not located reasonably close to the jobsite . 3.The enforcing agency may make exceptions to the requirements of this section when isolated jobsites are located in areas beyond the haul boundaries of the diversion facility . 4.408.2 CONSTRUCTION WASTE MANAGEMENT PLAN .Submit a construction waste management plan in conformance with Items 1 through 5.The construction waste management plan shall be updated as necessary and shall be available during construction for examination by the enforcing agency . 1.Identify the construction and demolition waste materials to be diverted from disposal by recycling , reuse on the project or salvage for future use or sale . 2.Specify if construction and demolition waste materials will be sorted on -site (source separated)or bulk mixed (single stream). 3.Identify diversion facilities where the construction and demolition waste material collected will be taken. 4.Identify construction methods employed to reduce the amount of construction and demolition waste generated . 5.Specify that the amount of construction and demolition waste materials diverted shall be calculated by weight or volume ,but not by both . 4.408.3 WASTE MANAGEMENT COMPANY . Utilize a waste management company ,approved by the enforcing agency ,which can provide verifiable documentation that the percentage of construction and demolition waste material diverted from the landfill complies with Section 4.408.1. Note: The owner or contractor may make the determination if the construction and demolition waste materials will be diverted by a waste management company . 4.408.4 WASTE STREAM REDUCTION ALTERNATIVE [LR]. Projects that generate a total combined weight of construction and demolition waste disposed of in landfills ,which do not exceed 3.4 lbs./sq.ft.of the building area shall meet the minimum 65%construction waste reduction requirement in Section 4.408.1 4.408.4.1 WASTE STREAM REDUCTION ALTERNATIVE . Projects that generate a total combined weight of construction and demolition waste disposed of in landfills ,which do not exceed 2 pounds per square foot of the building area ,shall meet the minimum 65%construction waste reduction requirement in Section 4.408.1 4.408.5 DOCUMENTATION .Documentation shall be provided to the enforcing agency which demonstrates compliance with Section 4.408.2,items 1 through 5,Section 4.408.3 or Section 4.408.4.. Notes: 1.Sample forms found in "A Guide to the California Green Building Standards Code (Residential)"located at www .hcd.ca.gov/CALGreen.html may be used to assist in documenting compliance with this section . 2.Mixed construction and demolition debris (C &D)processors can be located at the California Department of Resources Recycling and Recovery (CalRecycle ). 4.410 BUILDING MAINTENANCE AND OPERATION 4.410.1 OPERATION AND MAINTENANCE MANUAL .At the time of final inspection ,a manual,compact disc,web-based reference or other media acceptable to the enforcing agency which includes all of the following shall be placed in the building : 1.Directions to the owner or occupant that the manual shall remain with the building throughout the life cycle of the structure . 2.Operation and maintenance instructions for the following : a.Equipment and appliances ,including water -saving devices and systems ,HVAC systems , photovoltaic systems ,electric vehicle chargers ,water -heating systems and other major appliances and equipment . b.Roof and yard drainage ,including gutters and downspouts . c.Space conditioning systems ,including condensers and air filters . d.Landscape irrigation systems . e.Water reuse systems . 3.Information from local utility ,water and waste recovery providers on methods to further reduce resource consumption ,including recycle programs and locations . 4.Public transportation and /or carpool options available in the area . 5.Educational material on the positive impacts of an interior relative humidity between 30-60 percent and what methods an occupant may use to maintain the relative humidity level in that range . 6.Information about water -conserving landscape and irrigation design and controllers which conserve water . 7.Instructions for maintaining gutters and downspouts and the importance of diverting water at least 5 feet away from the foundation . 8.Information on required routine maintenance measures ,including,but not limited to ,caulking, painting ,grading around the building ,etc. 9.Information about state solar energy and incentive programs available . 10.A copy of all special inspections verifications required by the enforcing agency or this code . 11 .Information from the Department of Forestry and Fire Protection on maintenance of defensible space around residential structures . 12.Information and/or drawings identifying the location of grab bar reinforcements . 4.410.2 RECYCLING BY OCCUPANTS . Where 5 or more multifamily dwelling units are constructed on a building site ,provide readily accessible area (s)that serves all buildings on the site and are identified for the depositing,storage and collection of non -hazardous materials for recycling ,including (at a minimum)paper, corrugated cardboard ,glass,plastics,organic waster ,and metals,or meet a lawfully enacted local recycling ordinance,if more restrictive. Exception:Rural jurisdictions that meet and apply for the exemption in Public Resources Code Section 42649.82 (a)(2)(A)et seq.are note required to comply with the organic waste portion of this section. DIVISION 4.4 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY DIVISION 4.5 ENVIRONMENTAL QUALITY 4.303 INDOOR WATER USE 4.303.1 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS . Plumbing fixtures (water closets and urinals)and fittings (faucets and showerheads )shall comply with the sections 4.303.1.1,4.303.1.2,4.303.1.3, and 4.303.4.4. Note:All noncompliant plumbing fixtures in any residential real property shall be replaced with water -conserving plumbing fixtures .Plumbing fixture replacement is required prior to issuance of a certificate of final completion ,certificate of occupancy ,or final permit approval by the local building department .See Civil Code Section 1101 .1,et seq.,for the definition of a noncompliant plumbing fixture ,types of residential buildings affected and other important enactment dates . 4.303.1.1 Water Closets . The effective flush volume of all water closets shall not exceed 1.28 gallons per flush.Tank -type water closets shall be certified to the performance criteria of the U .S.EPA WaterSense Specification for Tank -type Toilets . Note:The effective flush volume of dual flush toilets is defined as the composite ,average flush volume of two reduced flushes and one full flush . 4.303.1.2 Urinals. The effective flush volume of wall mounted urinals shall not exceed 0.125 gallons per flush . The effective flush volume of all other urinals shall not exceed 0.5 gallons per flush . 4.303.1.3 Showerheads. 4.303.1.3.1 Single Showerhead. Showerheads shall have a maximum flow rate of not more than 1.8 gallons per minute at 80 psi.Showerheads shall be certified to the performance criteria of the U .S.EPA WaterSense Specification for Showerheads . 4.303.1.3.2 Multiple showerheads serving one shower.When a shower is served by more than one showerhead ,the combined flow rate of all the showerheads and /or other shower outlets controlled by a single valve shall not exceed 1.8 gallons per minute at 80 psi,or the shower shall be designed to only allow one shower outlet to be in operation at a time . Note:A hand -held shower shall be considered a showerhead . 4.303.1.4 Faucets. 4.303.1.4.1 Residential Lavatory Faucets . The maximum flow rate of residential lavatory faucets shall not exceed 1.2 gallons per minute at 60 psi.The minimum flow rate of residential lavatory faucets shall not be less than 0.8 gallons per minute at 20 psi. 4.303.1.4.2 Lavatory Faucets in Common and Public Use Areas . The maximum flow rate of lavatory faucets installed in common and public use areas (outside of dwellings or sleeping units )in residential buildings shall not exceed 0.5 gallons per minute at 60 psi. 4.303.1.4.3 Metering Faucets. Metering faucets when installed in residential buildings shall not deliver more than 0.2 gallons per cycle . 4.303.1.4.4 Kitchen Faucets. The maximum flow rate of kitchen faucets shall not exceed 1.8 gallons per minute at 60 psi.Kitchen faucets may temporarily increase the flow above the maximum rate ,but not to exceed 2.2 gallons per minute at 60 psi,and must default to a maximum flow rate of 1.8 gallons per minute at 60 psi. Note:Where complying faucets are unavailable ,aerators or other means may be used to achieve reduction . 4.303.1.4.5 Pre-rinse spray valves . When installed ,shall meet the requirements in the California Code of Regulations ,Title 20 (Appliance Efficiency Regulations ),Sections 1605.1 (h)(4)Table H -2,Section 1605.3 (h)(4)(A),and Section 1607 (d)(7)and shall be equipped with an integral automatic shutoff . FOR REFERENCE ONLY : The following table and code section have been reprinted from the California Code of Regulations ,Title 20 (Appliance Efficiency Regulations ),Section 1605.1 (h)(4)and Section 1605.3 (h)(4)(A). Title 20 Section 1605.3 (h)(4)(A):Commercial prerinse spray values manufactured on or after January 1,2006,shall have a minimum spray force of not less than 4.0 ounces-force (ozf)[113 grams-force(gf)] 4.303.2 Submeters for multifamily buildings and dwelling units in mixed-used residential/commercial buildings. Submeters shall be installed to measure water usage of individual rental dwelling units in accordance with the California Plumbing Code . 4.303.3 Standards for plumbing fixtures and fittings.Plumbing fixtures and fittings shall be installed in accordance with the California Plumbing Code ,and shall meet the applicable standards referenced in Table 1701.1 of the California Plumbing Code . TABLE -MAXIMUM FIXTURE WATER USE FIXTURE TYPE FLOW RATE SHOWER HEADS (RESIDENTIAL)1.8 GMP @ 80 PSI LAVATORY FAUCETS (RESIDENTIAL)MAX.1.2 GPM @ 60 PSI MIN.0.8 GPM @ 20 PSI LAVATORY FAUCETS IN COMMON &PUBLIC USE AREAS 0.5 GPM @ 60 PSI KITCHEN FAUCETS 1.8 GPM @ 60 PSI METERING FAUCETS 0.2 GAL/CYCLE WATER CLOSET 1.28 GAL/FLUSH URINALS 0.125 GAL/FLUSH 4.304 OUTDOOR WATER USE 4.304.1 OUTDOOR POTABLE WATER USE IN LANDSCAPE AREAS .Residential developments shall comply with a local water efficient landscape ordinance or the current California Department of Water Resources 'Model Water Efficient Landscape Ordinance (MWELO),whichever is more stringent . NOTES: 1.The Model Water Efficient Landscape Ordinance (MWELO)is located in the California Code Regulations , Title 23,Chapter 2.7,Division 2.MWELO and supporting documents ,including water budget calculator ,are available at :https://www .water .ca.gov/ ABBREVIATION DEFINITIONS : HCD Department of Housing and Community Development BSC California Building Standards Commission DSA-SS Division of the State Architect ,Structural Safety OSHPD Office of Statewide Health Planning and Development LR Low Rise HR High Rise AA Additions and Alterations N New NOTE: THIS TABLE COMPILES THE DATA IN SECTION 4.303.1,AND IS INCLUDED AS A CONVENIENCE FOR THE USER. SECTION 4.102 DEFINITIONS 4.102.1 DEFINITIONS The following terms are defined in Chapter 2 (and are included here for reference ) FRENCH DRAIN .A trench ,hole or other depressed area loosely filled with rock ,gravel,fragments of brick or similar pervious material used to collect or channel drainage or runoff water . WATTLES .Wattles are used to reduce sediment in runoff .Wattles are often constructed of natural plant materials such as hay ,straw or similar material shaped in the form of tubes and placed on a downflow slope .Wattles are also used for perimeter and inlet controls . 4.106 SITE DEVELOPMENT 4.106.1 GENERAL .Preservation and use of available natural resources shall be accomplished through evaluation and careful planning to minimize negative effects on the site and adjacent areas .Preservation of slopes , management of storm water drainage and erosion controls shall comply with this section . 4.106.2 STORM WATER DRAINAGE AND RETENTION DURING CONSTRUCTION .Projects which disturb less than one acre of soil and are not part of a larger common plan of development which in total disturbs one acre or more,shall manage storm water drainage during construction .In order to manage storm water drainage during construction ,one or more of the following measures shall be implemented to prevent flooding of adjacent property ,prevent erosion and retain soil runoff on the site . 1.Retention basins of sufficient size shall be utilized to retain storm water on the site . 2.Where storm water is conveyed to a public drainage system ,collection point ,gutter or similar disposal method ,water shall be filtered by use of a barrier system ,wattle or other method approved by the enforcing agency . 3.Compliance with a lawfully enacted storm water management ordinance . Note:Refer to the State Water Resources Control Board for projects which disturb one acre or more of soil ,or are part of a larger common plan of development which in total disturbs one acre or more of soil . (Website :https://www .waterboards .ca.gov/water_issues/programs/stormwater /construction.html) 4.106.3 GRADING AND PAVING .Construction plans shall indicate how the site grading or drainage system will manage all surface water flows to keep water from entering buildings .Examples of methods to manage surface water include ,but are not limited to ,the following : 1.Swales 2.Water collection and disposal systems 3.French drains 4.Water retention gardens 5.Other water measures which keep surface water away from buildings and aid in groundwater recharge . Exception:Additions and alterations not altering the drainage path . 4.106.4 Electric vehicle (EV)charging for new construction.New construction shall comply with Sections 4.106.4.1 or 4.106.4.2 to facilitate future installation and use of EV chargers .Electric vehicle supply equipment (EVSE)shall be installed in accordance with the California Electrical Code , Article 625 . Exceptions: 1.On a case-by-case basis ,where the local enforcing agency has determined EV charging and infrastructure are not feasible based upon one or more of the following conditions : 1.1 Where there is no local utility power supply or the local utility is unable to supply adequate power . 1.2 Where there is evidence suitable to the local enforcing agency substantiating that additional local utility infrastructure design requirements ,directly related to the implementation of Section 4.106.4,may adversely impact the construction cost of the project . 2.Accessory Dwelling Units (ADU)and Junior Accessory Dwelling Units (JADU)without additional parking facilities . 4.106.4.1 New one-and two-family dwellings and townhouses with attached private garages.For each dwelling unit ,install a listed raceway to accommodate a dedicated 208/240-volt branch circuit .The raceway shall not be less than trade size 1 (nominal 1-inch inside diameter ).The raceway shall originate at the main service or subpanel and shall terminate into a listed cabinet ,box or other enclosure in close proximity to the proposed location of an EV charger .Raceways are required to be continuous at enclosed ,inaccessible or concealed areas and spaces .The service panel and /or subpanel shall provide capacity to install a 40-ampere 208/240-volt minimum dedicated branch circuit and space (s)reserved to permit installation of a branch circuit overcurrent protective device . Exemption :A raceway is not required if a minimum 40-ampere 208/240-volt dedicated EV branch circuit is installed in close proximity to the proposed location of an EV charger at the time of original construction in accordance with the California Electrical Code . 4.106.4.1.1 Identification.The service panel or subpanel circuit directory shall identify the overcurrent protective device space (s)reserved for future EV charging as "EV CAPABLE ".The raceway termination location shall be permanently and visibly marked as "EV CAPABLE ". CHAPTER 3 GREEN BUILDING SECTION 301 GENERAL 301.1 SCOPE.Buildings shall be designed to include the green building measures specified as mandatory in the application checklists contained in this code .Voluntary green building measures are also included in the application checklists and may be included in the design and construction of structures covered by this code , but are not required unless adopted by a city ,county ,or city and county as specified in Section 101.7. 301.1.1 Additions and alterations . [HCD] The mandatory provisions of Chapter 4 shall be applied to additions or alterations of existing residential buildings where the addition or alteration increases the building's conditioned area ,volume,or size.The requirements shall apply only to and /or within the specific area of the addition or alteration . The mandatory provision of Section 4.106.4.2 may apply to additions or alterations of existing parking facilities or the addition of new parking facilities serving existing multifamily buildings .See Section 4.106.4.3 for application. Note: Repairs including ,but not limited to ,resurfacing,restriping and repairing or maintaining existing lighting fixtures are not considered alterations for the purpose of this section . Note:On and after January 1,2014,residential buildings undergoing permitted alterations ,additions,or improvements shall replace noncompliant plumbing fixtures with water -conserving plumbing fixtures . Plumbing fixture replacement is required prior to issuance of a certificate of final completion ,certificate of occupancy or final permit approval by the local building department .See Civil Code Section 1101 .1, et seq.,for the definition of a noncompliant plumbing fixture ,types of residential buildings affected and other important enactment dates . 301.2 LOW-RISE AND HIGH -RISE RESIDENTIAL BUILDINGS . [HCD] The provisions of individual sections of CALGreen may apply to either low -rise residential buildings high -rise residential buildings,or both.Individual sections will be designated by banners to indicate where the section applies specifically to low -rise only (LR)or high-rise only (HR).When the section applies to both low -rise and high-rise buildings ,no banner will be used . SECTION 302 MIXED OCCUPANCY BUILDINGS 302.1 MIXED OCCUPANCY BUILDINGS . In mixed occupancy buildings ,each portion of a building shall comply with the specific green building measures applicable to each specific occupancy . Exceptions: 1. [HCD]Accessory structures and accessory occupancies serving residential buildings shall comply with Chapter 4 and Appendix A 4,as applicable . 2. [HCD]For purposes of CALGreen,live/work units ,complying with Section 419 of the California Building Code ,shall not be considered mixed occupancies .Live/Work units shall comply with Chapter 4 and Appendix A 4,as applicable . 4.106.4.2 New multifamily dwellings,hotels and motels and new residential parking facilities. When parking is provided ,parking spaces for new multifamily dwellings ,hotels and motels shall meet the requirements of Sections 4.106.4.2.1 and 4.106.4.2.2.Calculations for spaces shall be rounded up to the nearest whole number .A parking space served by electric vehicle supply equipment or designed as a future EV charging space shall count as at least one standard automobile parking space only for the purpose of complying with any applicable minimum parking space requirements established by a local jurisdiction .See Vehicle Code Section 22511 .2 for further details . 4.106.4.2.1Multifamily development projects with less than 20 dwelling units;and hotels and motels with less than 20 sleeping units or guest rooms. The number of dwelling units ,sleeping units or guest rooms shall be based on all buildings on a project site subject to this section. 1.EV Capable.Ten (10)percent of the total number of parking spaces on a building site ,provided for all types of parking facilities ,shall be electric vehicle charging spaces (EV spaces)capable of supporting future Level 2 EVSE.Electrical load calculations shall demonstrate that the electrical panel service capacity and electrical system,including any on -site distribution transformer (s),have sufficient capacity to simultaneously charge all EVs at all required EV spaces at a minimum of 40 amperes. The service panel or subpanel circuit directory shall identify the overcurrent protective device space (s)reserved for future EV charging purposes as “EV CAPABLE ”in accordance with the California Electrical Code . Exceptions: 1.When EV chargers (Level 2 EVSE)are installed in a number equal to or greater than the required number of EV capable spaces . 2.When EV chargers (Level 2 EVSE)are installed in a number less than the required number of EV capable spaces,the number of EV capable spaces required may be reduced by a number equal to the number of EV chargers installed . Notes: a.Construction documents are intended to demonstrate the project ’s capability and capacity for facilitating future EV charging . b.There is no requirement for EV spaces to be constructed or available until receptacles for EV charging or EV chargers are installed for use . 2.EV Ready.Twenty -five (25)percent of the total number of parking spaces shall be equipped with low power Level 2 EV charging receptacles .For multifamily parking facilities ,no more than one receptacle is required per dwelling unit when more than one parking space is provided for use by a single dwelling unit . Exception:Areas of parking facilities served by parking lifts . 4.106.4.2.2 Multifamily development projects with 20 or more dwelling units,hotels and motels with 20 or more sleeping units or guest rooms. The number of dwelling units ,sleeping units or guest rooms shall be based on all buildings on a project site subject to this section. 1.EV Capable.Ten (10)percent of the total number of parking spaces on a building site ,provided for all types of parking facilities ,shall be electric vehicle charging spaces (EV spaces)capable of supporting future Level 2 EVSE.Electrical load calculations shall demonstrate that the electrical panel service capacity and electrical system,including any on -site distribution transformer (s),have sufficient capacity to simultaneously charge all EVs at all required EV spaces at a minimum of 40 amperes. The service panel or subpanel circuit directory shall identify the overcurrent protective device space (s)reserved for future EV charging purposes as “EV CAPABLE ”in accordance with the California Electrical Code . Exception:When EV chargers (Level 2 EVSE)are installed in a number greater than five (5)percent of parking spaces required by Section 4.106.4.2.2,Item 3,the number of EV capable spaces required may be reduced by a number equal to the number of EV chargers installed over the five (5)percent required . Notes: a.Construction documents shall show locations of future EV spaces . b.There is no requirement for EV spaces to be constructed or available until receptacles for EV charging or EV chargers are installed for use . 2.EV Ready. Twenty -five (25)percent of the total number of parking spaces shall be equipped with low power Level 2 EV charging receptacles .For multifamily parking facilities ,no more than one receptacle is required per dwelling unit when more than one parking space is provided for use by a single dwelling unit . Exception:Areas of parking facilities served by parking lifts . 3.EV Chargers. Five (5)percent of the total number of parking spaces shall be equipped with Level 2 EVSE. Where common use parking is provided ,at least one EV charger shall be located in the common use parking area and shall be available for use by all residents or guests . When low power Level 2 EV charging receptacles or Level 2 EVSE are installed beyond the minimum required , an automatic load management system (ALMS)may be used to reduce the maximum required electrical capacity to each space served by the ALMS .The electrical system and any on -site distribution transformers shall have sufficient capacity to deliver at least 3.3 kW simultaneously to each EV charging station (EVCS) served by the ALMS .The branch circuit shall have a minimum capacity of 40 amperes,and installed EVSE shall have a capacity of not less than 30 amperes.ALMS shall not be used to reduce the minimum required electrical capacity to the required EV capable spaces . 4.106.4.2.2.1 Electric vehicle charging stations (EVCS). Electric vehicle charging stations required by Section 4.106.4.2.2,Item 3,shall comply with Section 4.106.4.2.2.1. Exception:Electric vehicle charging stations serving public accommodations ,public housing ,motels and hotels shall not be required to comply with this section .See California Building Code ,Chapter 11 B,for applicable requirements. 4.106.4.2.2.1.1 Location. EVCS shall comply with at least one of the following options : 1.The charging space shall be located adjacent to an accessible parking space meeting the requirements of the California Building Code ,Chapter 11 A,to allow use of the EV charger from the accessible parking space . 2.The charging space shall be located on an accessible route ,as defined in the California Building Code , Chapter 2,to the building . Exception :Electric vehicle charging stations designed and constructed in compliance with the California Building Code ,Chapter 11 B,are not required to comply with Section 4.106.4.2.2.1.1 and Section 4.106.4.2.2.1.2,Item 3. 4.106.4.2.2.1.2 Electric vehicle charging stations (EVCS)dimensions. The charging spaces shall be designed to comply with the following : 1.The minimum length of each EV space shall be 18 feet (5486 mm). 2.The minimum width of each EV space shall be 9 feet (2743 mm). 3.One in every 25 charging spaces ,but not less than one ,shall also have an 8-foot (2438 mm)wide minimum aisle.A 5-foot (1524 mm)wide minimum aisle shall be permitted provided the minimum width of the EV space is 12 feet (3658 mm). a.Surface slope for this EV space and the aisle shall not exceed 1 unit vertical in 48 units horizontal (2.083 percent slope)in any direction . 4.106.4.2.2.1.3 Accessible EV spaces . In addition to the requirements in Sections 4.106.4.2.2.1.1 and 4.106.4.2.2.1.2,all EVSE,when installed ,shall comply with the accessibility provisions for EV chargers in the California Building Code ,Chapter 11 B.EV ready spaces and EVCS in multifamily developments shall comply with California Building Code ,Chapter 11 A,Section 1109 A. 4.106.4.2.3 EV space requirements . 1.Single EV space required .Install a listed raceway capable of accommodating a 208/240-volt dedicated branch circuit.The raceway shall not be less than trade size 1 (nominal 1-inch inside diameter ).The raceway shall originate at the main service or subpanel and shall terminate into a listed cabinet ,box or enclosure in close proximity to the location or the proposed location of the EV space .Construction documents shall identify the raceway termination point ,receptacle or charger location ,as applicable .The service panel and /or subpanel shall have a 40-ampere minimum dedicated branch circuit ,including branch circuit overcurrent protective device installed,or space(s)reserved to permit installation of a branch circuit overcurrent protective device . Exception:A raceway is not required if a minimum 40-ampere 208/240-volt dedicated EV branch circuit is installed in close proximity to the location or the proposed location of the EV space ,at the time of original construction in accordance with the California Electrical Code . 2.Multiple EV spaces required .Construction documents shall indicate the raceway termination point and the location of installed or future EV spaces ,receptacles or EV chargers .Construction documents shall also provide information on amperage of installed or future receptacles or EVSE ,raceway method (s),wiring schematics and electrical load calculations .Plan design shall be based upon a 40-ampere minimum branch circuit .Required raceways and related components that are planned to be installed underground ,enclosed,inaccessible or in concealed areas and spaces shall be installed at the time of original construction . SECTION 4.501 GENERAL 4.501.1 Scope The provisions of this chapter shall outline means of reducing the quality of air contaminants that are odorous , irritating and/or harmful to the comfort and well being of a building 's installers,occupants and neighbors . SECTION 4.502 DEFINITIONS 5.102.1 DEFINITIONS The following terms are defined in Chapter 2 (and are included here for reference ) AGRIFIBER PRODUCTS .Agrifiber products include wheatboard ,strawboard ,panel substrates and door cores,not including furniture ,fixtures and equipment (FF&E)not considered base building elements . COMPOSITE WOOD PRODUCTS.Composite wood products include hardwood plywood ,particleboard and medium density fiberboard . "Composite wood products "does not include hardboard ,structural plywood , structural panels ,structural composite lumber ,oriented strand board ,glued laminated timber ,prefabricated wood I -joists or finger -jointed lumber ,all as specified in California Code of regulations (CCR),title 17,Section 93120.1. DIRECT-VENT APPLIANCE .A fuel -burning appliance with a sealed combustion system that draws all air for combustion from the outside atmosphere and discharges all flue gases to the outside atmosphere . DISCLAIMER:THIS DOCUMENT IS PROVIDED AND INTENDED TO BE USED AS A MEANS TO INDICATE AREAS OF COMPLIANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS (CALGREEN)CODE.DUE TO THE VARIABLES BETWEEN BUILDING DEPARTMENT JURISDICTIONS ,THIS CHECKLIST IS TO BE USED ON AN INDIVIDUAL PROJECT BASIS AND MAY BE MODIFIED BY THE END USER TO MEET THOSE INDIVIDUAL NEEDS .THE END USER ASSUMES ALL RESPONSIBILITY ASSOCIATED WITH THE USE OF THIS DOCUMENT ,INCLUDING VERIFICATION WITH THE FULL CODE . Y N/AYN/AYN/AYN/A RESPON. PARTY RESPON. PARTY RESPON. PARTY RESPON. PARTY 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE RESIDENTIAL MANDATORY MEASURES ,SHEET 1 (July 1st 2024 )Y =YES N/A =NOT APPLICABLE RESPON.PARTY =RESPONSIBLE PARTY (ie:ARCHITECT,ENGINEER, OWNER,CONTRACTOR ,INSPECTOR ETC.) 4.201 GENERAL 4.201.1 SCOPE.For the purposes of mandatory energy efficiency standards in this code ,the California Energy Commission will continue to adopt mandatory standards . DIVISION 4.2 ENERGY EFFICIENCY TABLE H -2 STANDARDS FOR COMMERCIAL PRE -RINSE SPRAY VALUES MANUFACTURED ON OR AFTER JANUARY 28,2019 PRODUCT CLASS [spray force in ounce force (ozf)]MAXIMUM FLOW RATE (gpm) Product Class 1 (≤1.00 Product Class 2 (>5.0 ozf and ≤1.20 Product Class 3 (>8.0 ozf)1.28 Exception:A raceway is not required if a minimum 40-ampere 208/240-volt dedicated EV branch circuit is installed in close proximity to the location or the proposed location of the EV space at the time of original construction in accordance with the California Electrical Code . 4.106.4.2.4 Identification. The service panel or subpanel circuit directory shall identify the overcurrent protective device space (s)reserved for future EV charging purposes as “EV CAPABLE ”in accordance with the California Electrical Code . 4.106.4.2.5 Electric Vehicle Ready Space Signage . Electric vehicle ready spaces shall be identified by signage or pavement markings ,in compliance with Caltrans Traffic Operations Policy Directive 13-01 (Zero Emission Vehicle Signs and Pavement Markings )or its successor(s). 4.106.4.3 Electric vehicle charging for additions and alterations of parking facilities serving existing multifamily buildings. When new parking facilities are added ,or electrical systems or lighting of existing parking facilities are added or altered and the work requires a building permit ,ten (10)percent of the total number of parking spaces added or altered shall be electric vehicle charging spaces (EV spaces)capable of supporting future Level 2 EVSE. Notes: 1.Construction documents are intended to demonstrate the project ’s capability and capacity for facilitating future EV charging . 2.There is no requirement for EV spaces to be constructed or available until EV chargers are installed for use . N N N Y Y Y N N N N N N Y Y Y Y Y Y Y Y Y N N CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR RESPONSIBLE DESIGNER GSPublisherVersion 0.0.100.100 4 7 1 5 & 4 7 1 7 W . M C F A D D E N A V E , S A N T A A N A , CA 9 2 7 0 4 N E W A D D I T I O N T O N E W A D U sheet title: sheet number: REVISIONS NO.DATE DESCRIPTION DESIGN DRAWN ISSUED APPROVED NS JT T 1 .2 GREEN BUILDING SHEET N&NC 12 4 5 EA S T W A L N U T S T R E E T , ST E 11 2 PA S A D E N A , CA 91 1 0 6 MAXIMUM INCREMENTAL REACTIVITY (MIR).The maximum change in weight of ozone formed by adding a compound to the "Base Reactive Organic Gas (ROG)Mixture"per weight of compound added ,expressed to hundredths of a gram (g O³/g ROC). Note:MIR values for individual compounds and hydrocarbon solvents are specified in CCR ,Title 17,Sections 94700 and 94701. MOISTURE CONTENT.The weight of the water in wood expressed in percentage of the weight of the oven -dry wood . PRODUCT-WEIGHTED MIR (PWMIR). The sum of all weighted -MIR for all ingredients in a product subject to this article.The PWMIR is the total product reactivity expressed to hundredths of a gram of ozone formed per gram of product (excluding container and packaging ). Note:PWMIR is calculated according to equations found in CCR ,Title 17,Section 94521 (a). REACTIVE ORGANIC COMPOUND (ROC). Any compound that has the potential ,once emitted,to contribute to ozone formation in the troposphere . VOC. A volatile organic compound (VOC)broadly defined as a chemical compound based on carbon chains or rings with vapor pressures greater than 0.1 millimeters of mercury at room temperature .These compounds typically contain hydrogen and may contain oxygen ,nitrogen and other elements .See CCR Title 17,Section 94508(a). 4.503 FIREPLACES 4.503.1 GENERAL .Any installed gas fireplace shall be a direct -vent sealed-combustion type .Any installed woodstove or pellet stove shall comply with U .S.EPA New Source Performance Standards (NSPS)emission limits as applicable ,and shall have a permanent label indicating they are certified to meet the emission limits .Woodstoves , pellet stoves and fireplaces shall also comply with applicable local ordinances . 4.504 POLLUTANT CONTROL 4.504.1 COVERING OF DUCT OPENINGS &PROTECTION OF MECHANICAL EQUIPMENT DURING CONSTRUCTION.At the time of rough installation ,during storage on the construction site and until final startup of the heating ,cooling and ventilating equipment ,all duct and other related air distribution component openings shall be covered with tape ,plastic,sheet metal or other methods acceptable to the enforcing agency to reduce the amount of water ,dust or debris which may enter the system . 4.504.2 FINISH MATERIAL POLLUTANT CONTROL .Finish materials shall comply with this section . 4.504.2.1 Adhesives ,Sealants and Caulks.Adhesives,sealant and caulks used on the project shall meet the requirements of the following standards unless more stringent local or regional air pollution or air quality management district rules apply : 1.Adhesives ,adhesive bonding primers ,adhesive primers ,sealants,sealant primers and caulks shall comply with local or regional air pollution control or air quality management district rules where applicable or SCAQMD Rule 1168 VOC limits,as shown in Table 4.504.1 or 4.504.2,as applicable . Such products also shall comply with the Rule 1168 prohibition on the use of certain toxic compounds (chloroform,ethylene dichloride ,methylene chloride ,perchloroethylene and tricloroethylene ),except for aerosol products ,as specified in Subsection 2 below . 2.Aerosol adhesives ,and smaller unit sizes of adhesives ,and sealant or caulking compounds (in units of product ,less packaging ,which do not weigh more than 1 pound and do not consist of more than 16 fluid ounces )shall comply with statewide VOC standards and other requirements ,including prohibitions on use of certain toxic compounds ,of California Code of Regulations ,Title 17, commencing with section 94507. 4.504.2.2 Paints and Coatings.Architectural paints and coatings shall comply with VOC limits in Table 1 of the ARB Architectural Suggested Control Measure ,as shown in Table 4.504.3,unless more stringent local limits apply.The VOC content limit for coatings that do not meet the definitions for the specialty coatings categories listed in Table 4.504.3 shall be determined by classifying the coating as a Flat ,Nonflat or Nonflat-High Gloss coating,based on its gloss ,as defined in subsections 4.21,4.36,and 4.37 of the 2007 California Air Resources Board,Suggested Control Measure ,and the corresponding Flat ,Nonflat or Nonflat -High Gloss VOC limit in Table 4.504.3 shall apply . 4.504.2.3 Aerosol Paints and Coatings .Aerosol paints and coatings shall meet the Product -weighted MIR Limits for ROC in Section 94522(a)(2)and other requirements ,including prohibitions on use of certain toxic compounds and ozone depleting substances ,in Sections 94522(e)(1)and (f)(1)of California Code of Regulations ,Title 17,commencing with Section 94520;and in areas under the jurisdiction of the Bay Area Air Quality Management District additionally comply with the percent VOC by weight of product limits of Regulation 8,Rule 49. 4.504.2.4 Verification .Verification of compliance with this section shall be provided at the request of the enforcing agency .Documentation may include ,but is not limited to ,the following : 1.Manufacturer's product specification . 2.Field verification of on -site product containers . CHAPTER 7 INSTALLER &SPECIAL INSPECTOR QUALIFICATIONS 702 QUALIFICATIONS 702.1 INSTALLER TRAINING .HVAC system installers shall be trained and certified in the proper installation of HVAC systems including ducts and equipment by a nationally or regionally recognized training or certification program .Uncertified persons may perform HVAC installations when under the direct supervision and responsibility of a person trained and certified to install HVAC systems or contractor licensed to install HVAC systems . Examples of acceptable HVAC training and certification programs include but are not limited to the following : 1.State certified apprenticeship programs . 2.Public utility training programs . 3.Training programs sponsored by trade ,labor or statewide energy consulting or verification organizations . 4.Programs sponsored by manufacturing organizations . 5.Other programs acceptable to the enforcing agency . 702.2 SPECIAL INSPECTION [HCD].When required by the enforcing agency ,the owner or the responsible entity acting as the owner 's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code .Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed .In addition to other certifications or qualifications acceptable to the enforcing agency ,the following certifications or education may be considered by the enforcing agency when evaluating the qualifications of a special inspector : 1.Certification by a national or regional green building program or standard publisher . 2.Certification by a statewide energy consulting or verification organization ,such as HERS raters ,building performance contractors ,and home energy auditors . 3.Successful completion of a third party apprentice training program in the appropriate trade . 4.Other programs acceptable to the enforcing agency . Notes: 1.Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code . 2.HERS raters are special inspectors certified by the California Energy Commission (CEC)to rate homes in California according to the Home Energy Rating System (HERS). [BSC]When required by the enforcing agency ,the owner or the responsible entity acting as the owner 's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code.Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed .In addition,the special inspector shall have a certification from a recognized state,national or international association ,as determined by the local agency .The area of certification shall be closely related to the primary job function ,as determined by the local agency . Note: Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code . 703 VERIFICATIONS 703.1 DOCUMENTATION .Documentation used to show compliance with this code shall include but is not limited to,construction documents ,plans,specifications,builder or installer certification ,inspection reports ,or other methods acceptable to the enforcing agency which demonstrate substantial conformance .When specific documentation or special inspection is necessary to verify compliance ,that method of compliance will be specified in the appropriate section or identified applicable checklist . 4.505 INTERIOR MOISTURE CONTROL 4.505.1 General.Buildings shall meet or exceed the provisions of the California Building Standards Code . 4.505.2 CONCRETE SLAB FOUNDATIONS .Concrete slab foundations required to have a vapor retarder by California Building Code ,Chapter 19,or concrete slab -on-ground floors required to have a vapor retarder by the California Residential Code ,Chapter 5,shall also comply with this section . 4.505.2.1 Capillary break.A capillary break shall be installed in compliance with at least one of the following : 1.A 4-inch (101.6 mm)thick base of 1/2 inch (12.7mm)or larger clean aggregate shall be provided with a vapor barrier in direct contact with concrete and a concrete mix design ,which will address bleeding , shrinkage ,and curling ,shall be used .For additional information ,see American Concrete Institute , ACI 302.2R-06. 2.Other equivalent methods approved by the enforcing agency . 3.A slab design specified by a licensed design professional . 4.505.3 MOISTURE CONTENT OF BUILDING MATERIALS .Building materials with visible signs of water damage shall not be installed .Wall and floor framing shall not be enclosed when the framing members exceed 19 percent moisture content .Moisture content shall be verified in compliance with the following : 1.Moisture content shall be determined with either a probe -type or contact -type moisture meter .Equivalent moisture verification methods may be approved by the enforcing agency and shall satisfy requirements found in Section 101.8 of this code. 2.Moisture readings shall be taken at a point 2 feet (610 mm)to 4 feet (1219 mm)from the grade stamped end of each piece verified . 3.At least three random moisture readings shall be performed on wall and floor framing with documentation acceptable to the enforcing agency provided at the time of approval to enclose the wall and floor framing . Insulation products which are visibly wet or have a high moisture content shall be replaced or allowed to dry prior to enclosure in wall or floor cavities .Wet-applied insulation products shall follow the manufacturers 'drying recommendations prior to enclosure . 4.506 INDOOR AIR QUALITY AND EXHAUST 4.506.1 Bathroom exhaust fans.Each bathroom shall be mechanically ventilated and shall comply with the following : 1.Fans shall be ENERGY STAR compliant and be ducted to terminate outside the building . 2.Unless functioning as a component of a whole house ventilation system ,fans must be controlled by a humidity control . a.Humidity controls shall be capable of adjustment between a relative humidity range less than or equal to 50%to a maximum of 80%.A humidity control may utilize manual or automatic means of adjustment. b.A humidity control may be a separate component to the exhaust fan and is not required to be integral (i.e.,built-in) Notes: 1.For the purposes of this section ,a bathroom is a room which contains a bathtub ,shower or tub/shower combination . 2.Lighting integral to bathroom exhaust fans shall comply with the California Energy Code . 4.507 ENVIRONMENTAL COMFORT 4.507.2 HEATING AND AIR -CONDITIONING SYSTEM DESIGN.Heating and air conditioning systems shall be sized,designed and have their equipment selected using the following methods : 1.The heat loss and heat gain is established according to ANSI /ACCA 2 Manual J -2011 (Residential Load Calculation ),ASHRAE handbooks or other equivalent design software or methods . 2.Duct systems are sized according to ANSI /ACCA 1 Manual D -2014 (Residential Duct Systems ), ASHRAE handbooks or other equivalent design software or methods . 3.Select heating and cooling equipment according to ANSI /ACCA 3 Manual S -2014 (Residential Equipment Selection ),or other equivalent design software or methods . Exception:Use of alternate design temperatures necessary to ensure the system functions are acceptable. TABLE 4.504.1 -ADHESIVE VOC LIMIT 1,2 (Less Water and Less Exempt Compounds in Grams per Liter ) ARCHITECTURAL APPLICATIONS VOC LIMIT INDOOR CARPET ADHESIVES 50 CARPET PAD ADHESIVES 50 OUTDOOR CARPET ADHESIVES 150 WOOD FLOORING ADHESIVES 100 RUBBER FLOOR ADHESIVES 60 SUBFLOOR ADHESIVES 50 CERAMIC TILE ADHESIVES 65 VCT &ASPHALT TILE ADHESIVES 50 DRYWALL &PANEL ADHESIVES 50 COVE BASE ADHESIVES 50 MULTIPURPOSE CONSTRUCTION ADHESIVE 70 STRUCTURAL GLAZING ADHESIVES 100 SINGLE-PLY ROOF MEMBRANE ADHESIVES 250 OTHER ADHESIVES NOT LISTED 50 SPECIALTY APPLICATIONS PVC WELDING 510 CPVC WELDING 490 ABS WELDING 325 PLASTIC CEMENT WELDING 250 ADHESIVE PRIMER FOR PLASTIC 550 CONTACT ADHESIVE 80 SPECIAL PURPOSE CONTACT ADHESIVE 250 STRUCTURAL WOOD MEMBER ADHESIVE 140 TOP &TRIM ADHESIVE 250 SUBSTRATE SPECIFIC APPLICATIONS METAL TO METAL 30 PLASTIC FOAMS 50 POROUS MATERIAL (EXCEPT WOOD )50 WOOD 30 FIBERGLASS 80 1.IF AN ADHESIVE IS USED TO BOND DISSIMILAR SUBSTRATES TOGETHER , THE ADHESIVE WITH THE HIGHEST VOC CONTENT SHALL BE ALLOWED . 2.FOR ADDITIONAL INFORMATION REGARDING METHODS TO MEASURE THE VOC CONTENT SPECIFIED IN THIS TABLE ,SEE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168 . TABLE 4.504.2 -SEALANT VOC LIMIT (Less Water and Less Exempt Compounds in Grams per Liter ) SEALANTS VOC LIMIT ARCHITECTURAL 250 MARINE DECK 760 NONMEMBRANE ROOF 300 ROADWAY 250 SINGLE-PLY ROOF MEMBRANE 450 OTHER 420 SEALANT PRIMERS ARCHITECTURAL NON-POROUS 250 POROUS 775 MODIFIED BITUMINOUS 500 MARINE DECK 760 OTHER 750 TABLE 4.504.5 -FORMALDEHYDE LIMITS 1 MAXIMUM FORMALDEHYDE EMISSIONS IN PARTS PER MILLION PRODUCT CURRENT LIMIT HARDWOOD PLYWOOD VENEER CORE 0.05 HARDWOOD PLYWOOD COMPOSITE CORE 0.05 PARTICLE BOARD 0.09 MEDIUM DENSITY FIBERBOARD 0.11 THIN MEDIUM DENSITY FIBERBOARD2 0.13 1.VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIF .AIR RESOURCES BOARD,AIR TOXICS CONTROL MEASURE FOR COMPOSITE WOOD AS TESTED IN ACCORDANCE WITH ASTM E 1333.FOR ADDITIONAL INFORMATION ,SEE CALIF. CODE OF REGULATIONS ,TITLE 17,SECTIONS 93120 THROUGH 93120.12. 2.THIN MEDIUM DENSITY FIBERBOARD HAS A MAXIMUM THICKNESS OF 5/16" (8 MM). TABLE 4.504.3 -VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS 2,3 GRAMS OF VOC PER LITER OF COATING ,LESS WATER &LESS EXEMPT COMPOUNDS COATING CATEGORY VOC LIMIT FLAT COATINGS 50 NON-FLAT COATINGS 100 NONFLAT -HIGH GLOSS COATINGS 150 SPECIALTY COATINGS ALUMINUM ROOF COATINGS 400 BASEMENT SPECIALTY COATINGS 400 BITUMINOUS ROOF COATINGS 50 BITUMINOUS ROOF PRIMERS 350 BOND BREAKERS 350 CONCRETE CURING COMPOUNDS 350 CONCRETE/MASONRY SEALERS 100 DRIVEWAY SEALERS 50 DRY FOG COATINGS 150 FAUX FINISHING COATINGS 350 FIRE RESISTIVE COATINGS 350 FLOOR COATINGS 100 FORM-RELEASE COMPOUNDS 250 GRAPHIC ARTS COATINGS (SIGN PAINTS )500 HIGH TEMPERATURE COATINGS 420 INDUSTRIAL MAINTENANCE COATINGS 250 LOW SOLIDS COATINGS 1 120 MAGNESITE CEMENT COATINGS 450 MASTIC TEXTURE COATINGS 100 METALLIC PIGMENTED COATINGS 500 MULTICOLOR COATINGS 250 PRETREATMENT WASH PRIMERS 420 PRIMERS,SEALERS, &UNDERCOATERS 100 REACTIVE PENETRATING SEALERS 350 RECYCLED COATINGS 250 ROOF COATINGS 50 RUST PREVENTATIVE COATINGS 250 SHELLACS CLEAR 730 OPAQUE 550 SPECIALTY PRIMERS ,SEALERS & UNDERCOATERS 100 STAINS 250 STONE CONSOLIDANTS 450 SWIMMING POOL COATINGS 340 TRAFFIC MARKING COATINGS 100 TUB &TILE REFINISH COATINGS 420 WATERPROOFING MEMBRANES 250 WOOD COATINGS 275 WOOD PRESERVATIVES 350 ZINC-RICH PRIMERS 340 1.GRAMS OF VOC PER LITER OF COATING ,INCLUDING WATER & EXEMPT COMPOUNDS 2.THE SPECIFIED LIMITS REMAIN IN EFFECT UNLESS REVISED LIMITS ARE LISTED IN SUBSEQUENT COLUMNS IN THE TABLE . 3.VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR RESOURCES BOARD ,ARCHITECTURAL COATINGS SUGGESTED CONTROL MEASURE ,FEB.1,2008.MORE INFORMATION IS AVAILABLE FROM THE AIR RESOURCES BOARD . DIVISION 4.5 ENVIRONMENTAL QUALITY (continued) 4.504.3 CARPET SYSTEMS . All carpet installed in the building interior shall meet the requirements of the California Department of Public Health ,"Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers ,"Version 1.2,January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health 's website for certification programs and testing labs . https://www .cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.3.1 Carpet cushion. All carpet cushion installed in the building interior shall meet the requirements of the California Department of Public Health ,"Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers ,"Version 1.2,January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health 's website for certification programs and testing labs . https://www .cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.3.2 Carpet adhesive . All carpet adhesive shall meet the requirements of Table 4.504.1. 4.504.4 RESILIENT FLOORING SYSTEMS. Where resilient flooring is installed ,at least 80%of floor area receiving resilient flooring shall meet the requirements of the California Department of Public Health ,"Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers ," Version 1.2,January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health 's website for certification programs and testing labs . hhtps://www .cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.5 COMPOSITE WOOD PRODUCTS. Hardwood plywood ,particleboard and medium density fiberboard composite wood products used on the interior or exterior of the buildings shall meet the requirements for formaldehyde as specified in ARB 's Air Toxics Control Measure for Composite Wood (17 CCR 93120 et seq.), by or before the dates specified in those sections ,as shown in Table 4.504.5 4.504.5.1 Documentation. Verification of compliance with this section shall be provided as requested by the enforcing agency .Documentation shall include at least one of the following : 1.Product certifications and specifications . 2.Chain of custody certifications . 3.Product labeled and invoiced as meeting the Composite Wood Products regulation (see CCR ,Title 17,Section 93120,et seq.). 4.Exterior grade products marked as meeting the PS -1 or PS-2 standards of the Engineered Wood Association ,the Australian AS /NZS 2269,European 636 3S standards,and Canadian CSA 0121 ,CSA 0151,CSA 0153 and CSA 0325 standards. 5.Other methods acceptable to the enforcing agency . DISCLAIMER:THIS DOCUMENT IS PROVIDED AND INTENDED TO BE USED AS A MEANS TO INDICATE AREAS OF COMPLIANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS (CALGREEN)CODE.DUE TO THE VARIABLES BETWEEN BUILDING DEPARTMENT JURISDICTIONS ,THIS CHECKLIST IS TO BE USED ON AN INDIVIDUAL PROJECT BASIS AND MAY BE MODIFIED BY THE END USER TO MEET THOSE INDIVIDUAL NEEDS .THE END USER ASSUMES ALL RESPONSIBILITY ASSOCIATED WITH THE USE OF THIS DOCUMENT ,INCLUDING VERIFICATION WITH THE FULL CODE . Y N/AYN/AYN/AYN/A RESPON. PARTY RESPON. PARTY RESPON. PARTY RESPON. PARTY 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE RESIDENTIAL MANDATORY MEASURES ,SHEET 2 Y =YES N/A =NOT APPLICABLE RESPON.PARTY =RESPONSIBLE PARTY (ie:ARCHITECT ,ENGINEER, OWNER,CONTRACTOR ,INSPECTOR ETC.) N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR (July 1st 2024 ) RESPONSIBLE DESIGNER T24.1 31 0 . 8 9 2 . 0 5 1 7 92 0 1 b e l m a c a v e ba k e r s f i e l d c a 9 3 3 1 2 NOTICE: WRITTEN DIMENSIONS OF THESE DRAWINGS SHALL TAKE PREFERENCE OVER SCALED DIMENSION. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS SHOWN BY THESE PLANS. THE IDEAS, DRAWINGS AND LAYOUTS SHOWN IN THESE PLANS ARE THE INTELLECTUAL PROPERTY OF CASTRO DRAFTING AND DESIGN. THEREFORE, THEY MUST NOT BE REPRODUCED OR COPIED IN ANY FORM WITHOUT THE WRITTEN PERMISSION OF CASTRO DRAFTING AND DESIGN. SHEET NO.: 47 1 7 W M C F A D D E N A V E U N I T C SA N T A A N A C A 9 2 7 0 4 ma n u e l c a s t r o t2 4 p r e p a r e d b y : PR O J E C T A D D R E S S : t i t l e 2 4 e n e r g y c a l c u l a t i o n CA S T R O D R A F T I N G A N D D E S I G N @ G M A I L . C O M 47 1 7 W M C F A D D E N A V E U N I T C S A N T A A N A C A 9 2 7 0 4 AC C E S S O R Y D W E L L I N G U N I T ADMINISTRATIVE REQUIREMENTS: A) THE PERSON IN CHARGE OF THE CONSTRUCTION OR INSTALLATION, WHO IS ELEGIBLE UNDER DIVISION 3 OF THE BUSINESS AND PROFESSIONS CODE TO ACCEPT RESPONSIBILITY FOR THE CONSTRUCTION OR INSTALLATION OF REGULATED MANUFACTURED DEVICES SHALL POST, OR MAKE AVAILABLE WITH THE BUILDING PERMIT(S) ISSUED FOR THE BUILDIN, THE CERTIFICATE OF INSTALLATION DOCUMENTATION FOR MANUFACTURED DEVICES REGULATED BY THE APPLAINCE EFFICIENCY REGULATIONS OR PART 6. SUCH CERTIFICATE OF INSTALLATION DOCUMENTATION SHALL BE MADE AVAILABLE TO THE ENFORCEMENT AGENCY FOR ALL APPLICABLE INSPECTIONS. THESE CERTIFICATES SHALL: i) IDENTIFY FEATURES, MATERIALS, COMPONENTS, MANUFACTURED DEVICES AND SYSTEM DIAGNOSTIC RESULTS REQUIRED TO VERIFY COMPLIANCE WITH THE APPLIANCE EFFICIENCY REGULATIONS AND PART 6. ii) STATE THE NUMBER OF THE BUILDING PERMIT UNDER WHICH THE CONSTRUCTION OR INSTALLATION WAS PERFORMED, SECTIONS OF THE CERTIFICATE(S) FOR WHICH SUBMITTAL TO A HERS PROVIDER DATA REGISTRY IS REQUIRED, SHALL DISPLAY THE UNIQUE REGISTRATION NUMBER ASSIGNED BY THE HERS DATA REGISTRY. iii) INCLUDE A DECLARATION STATEMENT INDICATING THAT THE CONSTRUCTED OR INSTALLED FEATURES, MATERIALS COMPONENTS, OR MANUFACTURED DEVICES GIVEN IN THE PLANS AND SPECIFICATIONS APPROVED BY THE LOCAL ENFORCEMENT AGENCY. iv) BE SIGNED BY THE DOCUMENT AUTHOR TO CERTIFY THE DOCUMENTATION IS ACCURATE AND COMPLETE. v) BE SIGNED BY THE INDIVIDUAL ELIGIBLE UNDER DIVISION 3 OF THE BUSINESS AND PROFESSIONS CODE TO ACCEPT RESPONSIBILITY FOR CONSTRUCTION, OR INSTALLATION IN THE APPLICABLE CLASSIFICATION FOR THE SCOPE OF WORK SPECIFIED ON THE CERTIFICATE OF INSTALLATION DOCUMENT(S). SECTION 10-103 (a) 3A B) THE BUILDER SHALL PROVIDE THE BUILDING OWNER OR THE PERSON(S) RESPONSIBLE FOR OPERATION AND MAINTENANCE OF THE FEATURE, MATERIAL, COMPONENT OR MECHANICAL DEVICE INSTALLED (IN CASE OF MULTI-TENANT OR CENTRALLY OPERATED BUILDINGS) WITH THE FOLLOWING AT THE TIME OF OCCUPANCY: i) COMPLIANCE INFORMATION. THE APPROPRIATE COMPLETED AND SIGNED CERTIFICATE(S) OF COMPLIANCE, CERTIFICATE(S) OF INSTALLATION AND IF APPLICABLE CERTIFICATE(S) OF VERIFICATION DOCUMENTATION SUBMITTED. ii) OPERATION INFORMATION. THE APPROPRIATE CERTIFICATE(S) OF COMPLIANCE AND A LIST OF FEATURES, MATERIALS, COMPONENTS AND MECHANICAL DEVICES INSTALLED IN THE BUILDING AND INSTRUCTIONS ON HOW TO OPERATE THEM CORRECTLY AND EFFICIENTLY. iii) MAINTENANCE INFORMATION. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY STATED AND INCORPORATED ON A READILY ACCESSIBLE LABEL. THE LABEL MAY BE LIMITED TO IDENTIFYING THE OPERATION AND MAINTENANCE MANUAL,. iv) VENTILATION INFORMATION. A DESCRIPTION OF THE QUANTITY OF OUTDOOR AIR THAT THE VENTILATION SYSTEM IS DESIGNED TO PROVIDE TO THE BUILDING CONDITIONED SPACE AND INSTRUCTIONS FOR PROPER OPERATION AND MAINTENANCE.SECTION 10-103 (b) C) THE ENFORCEMENT AGENCY SHALL NOT ISSUE A CERTIFICATE OF OCCUPANCY UNTIL ALL REQUIRED CERTIFICATES OF VERIFICATION ARE POSTED AND MADE AVAILABLE TO THE BUILDING DEPARTMENT FOR ALL APPLICABLE INSPECTIONS, AND THAT ALL CERTIFICATED OF VERIFICATION CONFORM TO THE SPECIFICATIONS OF SECTION 10-103 (a)5.SECTION 10-103(d)2 ENERGY FEATURES SUMMARY BUILDING ENVELOPE REQUIREMENT HERS VERIFICATION SLAB FLOORS RAISED FLOORS WALLS ATTIC ROOFS ETERIOR WALLS (EISTING) ETERIOR WALLS (NEW) ROOF CEILING RADIANT BARRIER COOL ROOF (CRRC RATED) NA R-1 INSULATION (2 16 O.C.) NA NONE NONE R-15 INSULATION (2 16 O.C.) R-11 INSULATION (2 16 O.C.) R-30 INSULATION (210 16 O.C.) NONE AGED SOLAR REFLECTANCE NA THERMAL EMITTANCE NA NONE COOL ROOF (SPECIAL FEATURE) FENESTRATION WINDOWS GLAED DOORS SKYLIGHTS NFRC 0.30 U-FACTOR 0.23 SHGC NFRC 0.30 U-FACTOR 0.23 SHGC NONE NONE NONE NONE RAFTER (VAULTED) ROOFS NONE SOLAR PV SYSTEM NONE ADDITIONAL MEASURES NONE NONE MECHANICAL SYSTEM HEATING COOLING MINI - SPLIT HEAT PUMP MINI - SPLIT HEAT PUMP 12.5 HSPF 26.1 SEER 13. EER 1 DEGREES HEAT CAPACITY VERIFIED REFRIGERANT CHARGE DUCTS MINI - SPLIT HEAT PUMP DUCTLESS NONE WHOLE HOUSE FAN NONE NONE INDOOR AIR QUALITY (IAQ) FAN 35 CFM (DEFAULT EHAUST)NONE HVIKITCHEN RANGE HOOD INSTALLATION HVI CERTIFIED DOMESTIC HOT WATER GAS TANKLESS 0.1 UEF NONE COMPACT DISTRIBUTION NONE NONEPIPE INSULATION NONE NONE NONE NONE NONE NONE NONE 31 0 . 8 9 2 . 0 5 1 7 92 0 1 b e l m a c a v e ba k e r s f i e l d c a 9 3 3 1 2 NOTICE: WRITTEN DIMENSIONS OF THESE DRAWINGS SHALL TAKE PREFERENCE OVER SCALED DIMENSION. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS SHOWN BY THESE PLANS. THE IDEAS, DRAWINGS AND LAYOUTS SHOWN IN THESE PLANS ARE THE INTELLECTUAL PROPERTY OF CASTRO DRAFTING AND DESIGN. THEREFORE, THEY MUST NOT BE REPRODUCED OR COPIED IN ANY FORM WITHOUT THE WRITTEN PERMISSION OF CASTRO DRAFTING AND DESIGN. SHEET NO.: 47 1 7 W M C F A D D E N A V E U N I T C SA N T A A N A C A 9 2 7 0 4 ma n u e l c a s t r o t2 4 p r e p a r e d b y : PR O J E C T A D D R E S S : t i t l e 2 4 e n e r g y c a l c u l a t i o n CA S T R O D R A F T I N G A N D D E S I G N @ G M A I L . C O M T24.2 THIS PAGE INTENTIONALLY LEFT BLANK THIS PAGE INTENTIONALLY LEFT BLANK THIS PAGE INTENTIONALLY LEFT BLANK THIS PAGE INTENTIONALLY LEFT BLANK 31 0 . 8 9 2 . 0 5 1 7 92 0 1 b e l m a c a v e ba k e r s f i e l d c a 9 3 3 1 2 NOTICE: WRITTEN DIMENSIONS OF THESE DRAWINGS SHALL TAKE PREFERENCE OVER SCALED DIMENSION. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS SHOWN BY THESE PLANS. THE IDEAS, DRAWINGS AND LAYOUTS SHOWN IN THESE PLANS ARE THE INTELLECTUAL PROPERTY OF CASTRO DRAFTING AND DESIGN. THEREFORE, THEY MUST NOT BE REPRODUCED OR COPIED IN ANY FORM WITHOUT THE WRITTEN PERMISSION OF CASTRO DRAFTING AND DESIGN. SHEET NO.: 47 1 7 W M C F A D D E N A V E U N I T C SA N T A A N A C A 9 2 7 0 4 ma n u e l c a s t r o t2 4 p r e p a r e d b y : PR O J E C T A D D R E S S : t i t l e 2 4 e n e r g y c a l c u l a t i o n CA S T R O D R A F T I N G A N D D E S I G N @ G M A I L . C O M T24.3 THIS PAGE INTENTIONALLY LEFT BLANK 31 0 . 8 9 2 . 0 5 1 7 92 0 1 b e l m a c a v e ba k e r s f i e l d c a 9 3 3 1 2 NOTICE: WRITTEN DIMENSIONS OF THESE DRAWINGS SHALL TAKE PREFERENCE OVER SCALED DIMENSION. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS SHOWN BY THESE PLANS. THE IDEAS, DRAWINGS AND LAYOUTS SHOWN IN THESE PLANS ARE THE INTELLECTUAL PROPERTY OF CASTRO DRAFTING AND DESIGN. THEREFORE, THEY MUST NOT BE REPRODUCED OR COPIED IN ANY FORM WITHOUT THE WRITTEN PERMISSION OF CASTRO DRAFTING AND DESIGN. SHEET NO.: 47 1 7 W M C F A D D E N A V E U N I T C SA N T A A N A C A 9 2 7 0 4 ma n u e l c a s t r o t2 4 p r e p a r e d b y : PR O J E C T A D D R E S S : t i t l e 2 4 e n e r g y c a l c u l a t i o n CA S T R O D R A F T I N G A N D D E S I G N @ G M A I L . C O M T24.4 THIS PAGE INTENTIONALLY LEFT BLANK THIS PAGE INTENTIONALLY LEFT BLANK MLB CONSULTING AND ENGINEERING, INC 7918 Foothill Blvd, Sunland, CA 91040 info@mlbengineering.org 818-521-6342 STRUCTURAL CALCULATION PACKAGE FOR 4703 W MCFADDEN AVE SANTA ANA CA 92704 Prepared By: Date: MLB Consulting and Engineering, Inc. Gegam Burnazyan, P.E. 7918 Foothill Blvd Sunland, CA 91040 Tel: 818-521-6342 September 22, 2025 Table of Contents: Description Page Cover 1 Calculations 2 - 32 Project Information Type: ADU Number of Stories: 1 Roof Slope: 4:12 Location: Risk Category: II ASCE 7-16: TABLE 1.5-1 Design Criteria (LRFD) Roof DL =15 psf Wind Speed =95mph Attic DL =10 psf Roughness = Floor DL = 20 psf Exposure = Ext Wall DL =17 psf Topo Factor, K ZT = Int Wall DL =20 psf D Roof LL =20 psf TL =8.00 sec Attic LL =10 psf S1 =0.474 g Floor LL = 40 psf DS =1.063 g Bedroom LL =40 psf D1 =0.537 g Balcony LL =60 Materials Timber Species:Douglas-Fir Larch (DF-L) Grades: References 1 California Building Code, 2022 2 California Residential Code, 2022 3 NDS for Wood Construction, 2022 4 NDS Supplement, 2022 5 ACSE 7-16 Minimum Design Loads for Buildings and Other Structures 6 AWC SDPWS, 2022 7 Los Angeles Building Code, 2022 8 AISC 360-14 Live Loads Seismic Design Category 6.5 1 No.2, No.1, No.1 and better, Select Structural, Dense Select Structural, Parallam PSL 2.0E Seismic Dead Loads Wind B B 1 Vertical Loads Dead Loads Roof DL =15 psf Attic DL =10 psf Floor DL =20 psf Ext Wall DL =17 psf Int Wall DL =10 psf Live Loads Roof LL =20 psf Attic LL =10 psf Floor LL =40 psf Bedroom LL =40 psf Balcony = 60 psf Building Weight Area (sqft)Weight (k) Story 1 Roof 1773 26.6 Story 1 Attic 1398 14.0 Story 1 Ext Walls 1624 27.6 Story 1 Int Walls 760 7.6 Total Weight =75.8 kips ASCE 7-16: TABLE 4.3-1 Wind Load 4703 W MCFADDEN AVE SANTA ANA CA 92704 ASCE 7-16 Table 1.5-1 95 mph ASCE 7-16 Figure 26.5-1A ASCE 7-16 Sec 26.7.2 ASCE 7-16 Sec 26.7.3 ASCE 7-16 Sec 26.8.2 789 620 624 272 Exposure = B Location = Coordinates =33 44 22 N 117 55 54 W Risk Category = ii Wind Speed, V = Roughness = B Where a: 10% of least horizontal dimension or 0.4h, whichever is smaller, but not less than 4% of least horizontal dimension or 3ft (0.9m) Topographic Factor, KZT = 1 Ridge Height = Eave Height = Mean Roof Height, h = Roof Angle = Adjustment Factor, λ =1 Buidling Width = Building Length = a = Wind Load (Cont.) Zone PS30 (psf) PS= λKZT PS30 Area (ft2)Force (lb) Total (k) Wall A 24.1 24.1 31.6 763 Roof B 3.9 3.9 14.4 56 Wall C 17.4 17.4 382.4 6653 Roof D 4.0 4.0 174.2 697 E -10.7 -10.7 30.9 -331 F -14.6 -14.6 30.9 -451 G -7.7 -7.7 373.4 -2875 H -11.7 -11.7 373.4 -4369 Zone PS30 (psf) PS= λKZT PS30 Area (ft2)Force (lb) Total (k) Wall A 19.2 19.2 15.8 304 Roof B N/A N/A N/A N/A Wall C 12.7 12.7 174.8 2220 Roof D N/A N/A N/A N/A E -23.1 -23.1 30.9 -714 F -13.1 -13.1 30.9 -405 G -16.0 -16 373.4 -5975 H -10.1 -10.1 373.4 -3772 Case A: θ = 25 Ho r i z o n t a l 9.0 Ve r t i c a l Roof -8.0 Case B: θ = 0 Ho r i z o n t a l 2.5 Ve r t i c a l Roof -10.9 Seismic Load Seismic Design Category D see USGS Report Structural Height, hn =11.1 ft House Mean Roof Height Ct =0.02 ASCE 7-16 Table 12.8-2 x =0.75 ASC.E 7-16 Table 12.8-2 Approximate Fundamental Period, Ta = Cthn x =0.121 s ASCE 7-16 Eq. 12.8.2.1 T0=0.2SD1/SDS =0.101 s ASCE 7-16 Sec. 11.4.5 Ts=SD1/SDS =0.505 s ASCE 7-16 Sec. 11.4.5 TL =8.00 s see USGS Report S1 =0.474 g see USGS Report SDS =1.063 g see USGS Report SD1 =0.537 g see USGS Report Per ASCE 7-16 12.8.1.3,SS =1.329 g Consequentially,SDS = 2/3FaSS =1.063 g For Wood Shearwalls, R =6.5 ASCE 7-16 Table 12.2-1 For Special Reinforced CMU Shearwalls, R =5.0 ASCE 7-16 Table 12.2-1 Seismic Importance Factor, Ie =1.0 ASCE 7-16 Table 1.5-2 Redundancy Factor for Shear Walls, ρ =1.3 ASCE 7-16 Sec. 12.3.4.2 Cs =SDS/(R/Ie) =0.164 ASCE 7-16 Eq. 12.8-2 Must not exceed For T≤TL 0.682 ASCE 7-16 Eq. 12.8-3 For T>TL 45.00 ASCE 7-16 Eq. 12.8-4 Where S1 ≥ 0.6g Cs, shall not be less than 0.036 ASCE 7-16 Eq. 12.8-6 For CMU Shearwalls, Cs =SDS/(R/Ie) =0.213 ASCE 7-16 Eq. 12.8-7 Must not exceed For T≤TL 0.886 ASCE 7-16 Eq. 12.8-3 For T>TL 58.50 ASCE 7-16 Eq. 12.8-4 Where S1 ≥ 0.6g Cs, shall not be less than 0.047 ASCE 7-16 Eq. 12.8-6 Must not be less than 0.044SDSIe ≥ 0.01 0.047 ASCE 7-16 Eq. 12.8-5 Effective Building Seismic Weight, W = 58.2 kips Base Shear, V=CsW =9.5 kips ASCE 7-16 Eq. 12.8-1 Level hx hx k Wx(kip) Wxhx k Cvx Fx (kip)V (kip)Fx/Wx ΣFx/ΣWx Coeff Fpx (kip) Roof (D1)11.1 11.1 58 643 1.00 9.5 0.0 0.164 0.164 1.00 12.37 Σ =58.2 643 1.0 9.5 9.5 Equivalent Lateral Force Procedure Wood Beam LIC# : KW-06012765, Build:20.22.10.25 MLB Consulting & Engineering inc.(c) ENERCALC INC 1983-2022 DESCRIPTION:RR-1 Project File: MCFADDEN.ec6 Project Title: Engineer: CODE REFERENCES Calculations per NDS 2018, IBC 2021, CBC 2022, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase Load Resistance Factor D Douglas Fir-Larch No.2 900 900 1350 625 1600 580 180 575 31.21 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.0150, Lr = 0.020 ksf, Tributary Width = 1.330 ft, (ROOF) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.329: 1 Load Combination +1.20D+1.60Lr Span # where maximum occurs Span # 1 Location of maximum on span 3.750 ft 41.34 psi= = 2,325.02 psi 2x6Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +1.20D+1.60Lr = = = 311.04 psi== Section used for this span 2x6 Maximum Shear Stress Ratio 0.133 : 1 7.062 ft= = 765.88 psi Maximum Deflection 0 <360 865 Ratio =0 <180 Max Downward Transient Deflection 0.057 in 1572Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.104 in Ratio =>=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span #C C CCMCCLxi r Shear ValuesMax Stress Ratios M V fbMu fvFbVu FvSegment Length O t F Cfu +1.40D 0.0 0.00 0.00.0 1 0.195 0.079 0.60 1.300 1.151.00 1.00 0.21 339.5 1,743.8 0.10 233.318.3 0.00.0 1 0.189 0.076 0.80 1.300 1.151.00 1.00 0.28 439.4 2,325.0 0.13 311.023.7 0.00.0 1 0.125 0.051 0.80 1.300 1.151.00 1.00 0.18 291.0 2,325.0 0.09 311.015.7 0.00.0 1 0.329 0.133 0.80 1.300 1.151.00 1.00 0.48 765.9 2,325.0 0.23 311.041.3 0.00.0 1 0.075 0.030 1.00 1.300 1.151.00 1.00 0.14 218.3 2,906.3 0.06 388.811.8 . Wood Beam LIC# : KW-06012765, Build:20.22.10.25 MLB Consulting & Engineering inc.(c) ENERCALC INC 1983-2022 DESCRIPTION:RR-1 Project File: MCFADDEN.ec6 Project Title: Engineer: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.1040 3.777 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.181 0.181 Max Upward from Load Combinations 0.181 0.181 Max Upward from Load Cases 0.100 0.100 D Only 0.082 0.082 +D+Lr 0.181 0.181 +D+0.750Lr 0.156 0.156 +0.60D 0.049 0.049 Lr Only 0.100 0.100 Wood Beam LIC# : KW-06012765, Build:20.22.10.25 MLB Consulting & Engineering inc.(c) ENERCALC INC 1983-2022 DESCRIPTION:HVB-1 Project File: MCFADDEN.ec6 Project Title: Engineer: CODE REFERENCES Calculations per NDS 2018, IBC 2021, CBC 2022, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase Load Resistance Factor D Douglas Fir-Larch No.2 875 875 600 625 1300 470 170 425 31.21 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Load for Span Number 1 Varying Uniform Load : D= 0.0150->0.0150, Lr= 0.020->0.020 ksf, Extent = 0.0 -->> 10.50 ft, Trib Width = 4.0->1.0 ft, (ROOF) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.317: 1 Load Combination +1.20D+1.60Lr Span # where maximum occurs Span # 1 Location of maximum on span 4.752 ft 41.72 psi= = 2,260.44 psi 4x8Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +1.20D+1.60Lr = = = 293.76 psi== Section used for this span 4x8 Maximum Shear Stress Ratio 0.142 : 1 0.000 ft= = 716.08 psi Maximum Deflection 0 <360 711 Ratio =0 <180 Max Downward Transient Deflection 0.095 in 1322Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.177 in Ratio =>=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span #C C CCMCCLxi r Shear ValuesMax Stress Ratios M V fbMu fvFbVu FvSegment Length O t F Cfu +1.40D 0.0 0.00 0.00.0 1 0.193 0.086 0.60 1.300 1.151.00 1.00 0.84 327.1 1,695.3 0.32 220.318.9 0.00.0 1 0.184 0.082 0.80 1.300 1.151.00 1.00 1.06 416.5 2,260.4 0.41 293.824.2 0.00.0 1 0.124 0.055 0.80 1.300 1.151.00 1.00 0.72 280.4 2,260.4 0.27 293.816.2 0.00.0 1 0.317 0.142 0.80 1.300 1.151.00 1.00 1.83 716.1 2,260.4 0.71 293.841.7 0.00.0 Wood Beam LIC# : KW-06012765, Build:20.22.10.25 MLB Consulting & Engineering inc.(c) ENERCALC INC 1983-2022 DESCRIPTION:HVB-1 Project File: MCFADDEN.ec6 Project Title: Engineer: Maximum Forces & Stresses for Load Combinations Span #C C CCMCCLxi r Shear ValuesMax Stress Ratios M V fbMu fvFbVu FvSegment Length O t F Cfu 1.00Length = 10.50 ft 1 0.074 0.033 1.00 1.300 1.151.00 1.00 0.54 210.3 2,825.6 0.21 367.212.1 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.1772 5.135 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.580 0.396 Max Upward from Load Combinations 0.580 0.396 Max Upward from Load Cases 0.315 0.210 D Only 0.265 0.186 +D+Lr 0.580 0.396 +D+0.750Lr 0.501 0.344 +0.60D 0.159 0.112 Lr Only 0.315 0.210 Wood Beam LIC# : KW-06012765, Build:20.22.10.25 MLB Consulting & Engineering inc.(c) ENERCALC INC 1983-2022 DESCRIPTION:CJ-1 Project File: MCFADDEN.ec6 Project Title: Engineer: CODE REFERENCES Calculations per NDS 2018, IBC 2021, CBC 2022, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase Load Resistance Factor D Douglas Fir-Larch No.2 900 900 1350 625 1600 580 180 575 31.21 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.010, L = 0.020 ksf, Tributary Width = 1.330 ft, (CEILING) Point Load : D = 0.150, Lr = 0.20 k @ 7.50 ft, (RIDGE LOAD) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.905: 1 Load Combination +1.20D+1.60Lr+L Span # where maximum occurs Span # 1 Location of maximum on span 7.500 ft 60.64 psi= = 1,967.33 psi 2x10Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +1.20D+1.60Lr+L = = = 311.04 psi== Section used for this span 2x10 Maximum Shear Stress Ratio 0.195 : 1 14.234 ft= = 1,780.31 psi Maximum Deflection 0 <360 364 Ratio =0 <180 Max Downward Transient Deflection 0.193 in 934Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.494 in Ratio =>=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : L Only n/a Span: 1 : +D+0.750Lr+0.750L n/a .Maximum Forces & Stresses for Load Combinations Span #C C CCMCCLxi r Shear ValuesMax Stress Ratios M V fbMu fvFbVu FvSegment Length O t F Cfu +1.40D 0.0 0.00 0.00.0 1 0.544 0.120 0.60 1.100 1.151.00 1.00 1.43 802.0 1,475.5 0.26 233.328.0 0.00.0 1 0.798 0.194 0.80 1.100 1.151.00 1.00 2.80 1,569.3 1,967.3 0.56 311.060.4 0.00.0 1 0.691 0.177 0.80 1.100 1.151.00 1.00 2.42 1,358.9 1,967.3 0.51 311.055.0 0.00.0 1 0.905 0.195 0.80 1.100 1.151.00 1.00 3.17 1,780.3 1,967.3 0.56 311.060.6 0.00.0 1 0.692 0.133 0.80 1.100 1.151.00 1.00 2.43 1,360.6 1,967.3 0.38 311.041.3 Wood Beam LIC# : KW-06012765, Build:20.22.10.25 MLB Consulting & Engineering inc.(c) ENERCALC INC 1983-2022 DESCRIPTION:CJ-1 Project File: MCFADDEN.ec6 Project Title: Engineer: Maximum Forces & Stresses for Load Combinations Span #C C CCMCCLxi r Shear ValuesMax Stress Ratios M V fbMu fvFbVu FvSegment Length O t F Cfu 1.00+1.20D+L 1.100 1.151.00 1.00 0.0 0.00 0.00.0 1 0.563 0.139 0.80 1.100 1.151.00 1.00 1.97 1,107.1 1,967.3 0.40 311.043.3 0.00.0 1 0.349 0.077 0.80 1.100 1.151.00 1.00 1.23 687.4 1,967.3 0.22 311.024.0 0.00.0 1 0.536 0.125 1.00 1.100 1.151.00 1.00 2.35 1,317.5 2,459.2 0.45 388.848.7 0.00.0 1 0.210 0.046 1.00 1.100 1.151.00 1.00 0.92 515.6 2,459.2 0.17 388.818.0 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+0.750Lr+0.750L 1 0.4940 7.555 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.422 0.422 Max Upward from Load Combinations 0.422 0.422 Max Upward from Load Cases 0.200 0.200 D Only 0.197 0.197 +D+L 0.397 0.397 +D+Lr 0.297 0.297 +D+0.750Lr+0.750L 0.422 0.422 +D+0.750L 0.347 0.347 +0.60D 0.118 0.118 Lr Only 0.100 0.100 L Only 0.200 0.200 Wood Beam LIC# : KW-06012765, Build:20.22.10.25 MLB Consulting & Engineering inc.(c) ENERCALC INC 1983-2022 DESCRIPTION:RB-1 Project File: MCFADDEN.ec6 Project Title: Engineer: CODE REFERENCES Calculations per NDS 2018, IBC 2021, CBC 2022, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase Load Resistance Factor D Douglas Fir-Larch No.2 875 875 600 625 1300 470 170 425 31.21 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.0150, Lr = 0.020 ksf, Tributary Width = 7.50 ft, (RR-1) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.037: 1 Load Combination +1.20D+1.60Lr Span # where maximum occurs Span # 1 Location of maximum on span 0.665 ft 3.29 psi= = 2,086.56 psi 2x8Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +1.20D+1.60Lr = = = 293.76 psi== Section used for this span 2x8 Maximum Shear Stress Ratio 0.011 : 1 0.728 ft= = 76.29 psi Maximum Deflection 0 <360 52695 Ratio =0 <180 Max Downward Transient Deflection 0 in 0Ratio =<360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.000 in Ratio =>=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v n/a n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span #C C CCMCCLxi r Shear ValuesMax Stress Ratios M V fbMu fvFbVu FvSegment Length O t F Cfu +1.40D 0.0 0.00 0.00.0 1 0.021 0.006 0.60 1.200 1.151.00 1.00 0.04 32.5 1,564.9 0.01 220.31.4 0.00.0 1 0.021 0.006 0.80 1.200 1.151.00 1.00 0.05 43.0 2,086.6 0.01 293.81.9 0.00.0 1 0.013 0.004 0.80 1.200 1.151.00 1.00 0.03 27.8 2,086.6 0.01 293.81.2 0.00.0 1 0.037 0.011 0.80 1.200 1.151.00 1.00 0.08 76.3 2,086.6 0.02 293.83.3 0.00.0 1 0.008 0.002 1.00 1.200 1.151.00 1.00 0.02 20.9 2,608.2 0.01 367.20.9 . Wood Beam LIC# : KW-06012765, Build:20.22.10.25 MLB Consulting & Engineering inc.(c) ENERCALC INC 1983-2022 DESCRIPTION:RB-1 Project File: MCFADDEN.ec6 Project Title: Engineer: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.0003 0.670 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.176 0.176 Max Upward from Load Combinations 0.176 0.176 Max Upward from Load Cases 0.100 0.100 D Only 0.076 0.076 +D+Lr 0.176 0.176 +D+0.750Lr 0.151 0.151 +0.60D 0.046 0.046 Lr Only 0.100 0.100 Wood Beam LIC# : KW-06012765, Build:20.22.10.25 MLB Consulting & Engineering inc.(c) ENERCALC INC 1983-2022 DESCRIPTION:RB-2 Project File: MCFADDEN.ec6 Project Title: Engineer: CODE REFERENCES Calculations per NDS 2018, IBC 2021, CBC 2022, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase Load Resistance Factor D Douglas Fir-Larch No.2 875.0 875.0 600.0 625.0 1,300.0 470.0 170.0 425.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.0150, Lr = 0.020 ksf, Tributary Width = 7.0 ft, (RR-1) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.772: 1 Load Combination +1.20D+1.60Lr Span # where maximum occurs Span # 1 Location of maximum on span 5.000 ft 93.09 psi= = 2,260.44 psi 4x8Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +1.20D+1.60Lr = = = 293.76 psi== Section used for this span 4x8 Maximum Shear Stress Ratio 0.317 : 1 0.000 ft= = 1,744.53 psi Maximum Deflection 0 <360 305 Ratio =0 <180 Max Downward Transient Deflection 0.219 in 547Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.392 in Ratio =>=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span #C C CCMCCLxi r Shear ValuesMax Stress Ratios M V fbMu fvFbVu FvSegment Length O t F Cfu +1.40D 0.0 0.00 0.00.0 1 0.446 0.183 0.60 1.300 1.151.00 1.00 1.93 756.8 1,695.3 0.68 220.340.4 0.00.0 1 0.438 0.180 0.80 1.300 1.151.00 1.00 2.53 991.1 2,260.4 0.89 293.852.9 0.00.0 1 0.287 0.118 0.80 1.300 1.151.00 1.00 1.66 648.7 2,260.4 0.59 293.834.6 0.00.0 1 0.772 0.317 0.80 1.300 1.151.00 1.00 4.46 1,744.5 2,260.4 1.57 293.893.1 0.00.0 1 0.172 0.071 1.00 1.300 1.151.00 1.00 1.24 486.5 2,825.6 0.44 367.226.0 . Wood Beam LIC# : KW-06012765, Build:20.22.10.25 MLB Consulting & Engineering inc.(c) ENERCALC INC 1983-2022 DESCRIPTION:RB-2 Project File: MCFADDEN.ec6 Project Title: Engineer: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.3923 5.036 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 1.252 1.252 Max Upward from Load Combinations 1.252 1.252 Max Upward from Load Cases 0.700 0.700 D Only 0.552 0.552 +D+Lr 1.252 1.252 +D+0.750Lr 1.077 1.077 +0.60D 0.331 0.331 Lr Only 0.700 0.700 Wood Beam LIC# : KW-06012765, Build:20.22.10.25 MLB Consulting & Engineering inc.(c) ENERCALC INC 1983-2022 DESCRIPTION:EX HIP Project File: MCFADDEN.ec6 Project Title: Engineer: CODE REFERENCES Calculations per NDS 2018, IBC 2021, CBC 2022, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase Load Resistance Factor D Douglas Fir-Larch No.2 875 875 600 625 1300 470 170 425 31.21 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Load for Span Number 1 Varying Uniform Load : D= 0.0150->0.0150, Lr= 0.020->0.020 ksf, Extent = 0.0 -->> 12.0 ft, Trib Width = 7.0->1.0 ft, (RR-1) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.653: 1 Load Combination +1.20D+1.60Lr Span # where maximum occurs Span # 1 Location of maximum on span 5.299 ft 79.25 psi= = 2,260.44 psi 4x8Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +1.20D+1.60Lr = = = 293.76 psi== Section used for this span 4x8 Maximum Shear Stress Ratio 0.270 : 1 0.000 ft= = 1,476.15 psi Maximum Deflection 0 <360 304 Ratio =0 <180 Max Downward Transient Deflection 0.260 in 553Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.473 in Ratio =>=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span #C C CCMCCLxi r Shear ValuesMax Stress Ratios M V fbMu fvFbVu FvSegment Length O t F Cfu +1.40D 0.0 0.00 0.00.0 1 0.386 0.158 0.60 1.300 1.151.00 1.00 1.67 654.3 1,695.3 0.59 220.334.9 0.00.0 1 0.375 0.154 0.80 1.300 1.151.00 1.00 2.16 846.8 2,260.4 0.77 293.845.3 0.00.0 1 0.248 0.102 0.80 1.300 1.151.00 1.00 1.43 560.8 2,260.4 0.51 293.829.9 0.00.0 1 0.653 0.270 0.80 1.300 1.151.00 1.00 3.77 1,476.2 2,260.4 1.34 293.879.2 0.00.0 Wood Beam LIC# : KW-06012765, Build:20.22.10.25 MLB Consulting & Engineering inc.(c) ENERCALC INC 1983-2022 DESCRIPTION:EX HIP Project File: MCFADDEN.ec6 Project Title: Engineer: Maximum Forces & Stresses for Load Combinations Span #C C CCMCCLxi r Shear ValuesMax Stress Ratios M V fbMu fvFbVu FvSegment Length O t F Cfu 1.00Length = 12.0 ft 1 0.149 0.061 1.00 1.300 1.151.00 1.00 1.07 420.6 2,825.6 0.38 367.222.4 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.4731 5.869 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 1.083 0.663 Max Upward from Load Combinations 1.083 0.663 Max Upward from Load Cases 0.600 0.360 D Only 0.483 0.303 +D+Lr 1.083 0.663 +D+0.750Lr 0.933 0.573 +0.60D 0.290 0.182 Lr Only 0.600 0.360 Lateral Load Resisting System Design Horizontal Diaphragm Design Roof Diaphragm (D-3)Governing Case Froof = QE =12.37 kips See Seismic Load Calculations Redundancy Factor for Diaphragm, ρ = Overstrength Factor, Ω = E = ρQE =12.4 kips ASCE 7-16 (12.4-3) Area Load, a = Redundancy Factor for Shear Walls, ρ = Load Transferred to Shear Walls = Loading Case 1 Total Length, L =40.0 ft Max Width, W =16.0 ft L/W Ratio = 2.50 <4:1 Satisfactory Shear at Supports = Distance to Shear Wall Line = Min Shearing Distance = Shear Transferred from above =value at the location of max shear Max Shear, Vu =0.1 kips Max Unit Shear, Vunit =4 plf Chord Design Linear Load on the Diaphragm, w = aW = 112 plf Moment on the Diaphragm, Mu = wL2/8 =22.3 k-ft Chord Axial Load, Tu = Cu =Mu/W =1395 lb Use 1 DF-L No.2 or larger w/1 CMST14 Strap(s) at splices Tall =9781 lb Tall =9271 lb DCR = Tu/Tall =0.143 <1 Satisfactory DCR = Tu/Tall =0.150 <1 Satisfactory Alternatively, use 2 continuous DF-L No.2 or larger Call =17605 lb Tall =9781 lb DCR = Cu/Call =0.040 <1 Satisfactory DCR = Tu/Tall =0.071 <1 Satisfactory Lateral Load Resisting System Design (Cont.) Horizontal Diaphragm Design Loading Case 2 Blocked Diaphragm Total Length, L =16.0 ft Max Width, W =40.0 ft L/W Ratio = 0.40 <4:1 Satisfactory Shear at Supports =2.2 kips Distance to Shear Wall Line =31.0 ft Min Shearing Distance =40.0 ft Shear Transferred from above =0.0 kips value at the location of max shear Max Shear, Vu =6.4 kips Max Unit Shear, Vunit =160 plf Chord Design 10.00 Linear Load on the Diaphragm, w = aW = 279 plf Moment on the Diaphragm, Mu = wL2/8 =8.9 k-ft Chord Axial Load, Tu = Cu =Mu/W =223 lb Use 1 2x4 DF-L No.2 or larger w/1 CMST14 Strap(s) at splices Tall =9781 lb Tall =9271 lb DCR = Tu/Tall =0.023 <1 Satisfactory DCR = Tu/Tall =0.024 <1 Satisfactory Alternatively, use 1 continuous 2x4 DF-L No.2 or larger Call =17605 lb Tall =9781 lb DCR = Cu/Call =0.013 <1 Satisfactory DCR = Tu/Tall =0.023 <1 Satisfactory Summary of Results 4 plf 160 plf Required Nominal Resistance, Vn = Vu/φ 201 plf Use 15/32" blocked Sheathing Panel w/ 10d nails @6-6-12 L Provided Resistance Vn =580 plf φ =0.8 DCR = Vu/φVn =0.346 <1 Satisfactory Loading Case Max Unit Shear, Vu 1 2 Lateral Load Resisting System Design (Cont.) Vertical Diaphragm Design Roof Shear Walls Loading Case 1 Shear Wall 1.1 (S-1.1)Blocked Panel Segmented Shear Wall Length, bs =44.00 ft Height, h =8.0 ft h/bs Ratio =0.2 ≤2:1 Satisfactory, No Reduction Req-d Aspect Ratio Factor, (WPS) = 1.0 ANSI/AWC SDPWS-2015 4.3.4.2 Tributary Area, AT =350 ft2 for Shear Wall Line Diaphragm Area Load =7.0 psf see Diaphragm Calculations Load from SW Line above =0 lb for Shear Wall Line Linear Shear Wall Load, w =Vu /bs =55 plf Use TYPE A Shear Wall Seismic Shear Resistance, φVs =440 plf see Shear Wall Capacity Calcs DCR=Vu/φVs =0.126 <1 Satisfactory Deflection Calculation use 4x4 DF-L No.2 end posts minimum Elastic Modulus of End Posts, E = 1600000 psi End Post Cross-Sectional Area, A =12.25 in2 Apparent Shear Wall Stiffness, Ga =13.0 kips/in Anchorage Elongation, Δa =0.153 in Shear Wall Deflection, δ sw =0.062 in ANSI/AWC SDPWS-2015 (4.3-1) Holdown Design Roof Ceiling Ext. Wall DL, psf 15 10 17 WT, ft 5 5 9.0 Du = (0.9-0.2SDS)D = 191 plf Post Compression Load, C=hw = 444 lb Holdown Tension Load from SW above =0 lb Strap, lb Load -3760 Provide S 75% Holdown Reduction applied Capacity 4913 see Holdown Capacity Calcs DCR -0.765 Satisfactory Footing, lb -3760 G 3294 Holdowns -1.142 Lateral Load Resisting System Design (Cont.) Vertical Diaphragm Design Roof Shear Walls Loading Case 1 Shear Wall 1.2 (S-1.2) Blocked Panel Segmented Shear Wall Length, bs =4.66 ft Height, h =8.0 ft h/bs Ratio =1.7 ≤2:1 Satisfactory, No Reduction Req-d Aspect Ratio Factor, (WPS) = 1.0 ANSI/AWC SDPWS-2015 4.3.4.2 Tributary Area, AT =340 ft2 for Shear Wall Line Diaphragm Area Load =7.0 psf see Diaphragm Calculations Load from SW Line above =0 lb for Shear Wall Line Linear Shear Wall Load, w =Vu /bs =252 plf Use TYPE A Shear Wall Seismic Shear Resistance, φVs =440 plf see Shear Wall Capacity Calcs DCR=Vu/φVs =0.573 <1 Satisfactory Deflection Calculation use 4x4 DF-L No.2 end posts minimum Elastic Modulus of End Posts, E = 1600000 psi End Post Cross-Sectional Area, A =12.25 in2 Apparent Shear Wall Stiffness, Ga =13.0 kips/in Anchorage Elongation, Δa =0.064 in Shear Wall Deflection, δ sw =0.276 in ANSI/AWC SDPWS-2015 (4.3-1) Holdown Design Roof Ceiling Ext. Wall DL, psf 15 10 17 WT, ft 5 5 9.0 Du = (0.9-0.2SDS)D = 191 plf Post Compression Load, C=hw = 2017 lb Holdown Tension Load from SW above =0 lb Strap, lb Load 1571 Provide S 75% Holdown Reduction applied Capacity 4913 see Holdown Capacity Calcs DCR 0.320 Satisfactory Holdowns Footing, lb 1571 G 3294 0.477 Lateral Load Resisting System Design (Cont.) Vertical Diaphragm Design Roof Shear Walls Loading Case 1 Shear Wall 1.3 (S-1.3) Blocked Panel Segmented Shear Wall Length, bs =4.75 ft Height, h =8.0 ft h/bs Ratio =1.7 ≤2:1 Satisfactory, No Reduction Req-d Aspect Ratio Factor, (WPS) = 1.0 ANSI/AWC SDPWS-2015 4.3.4.2 Tributary Area, AT =340 ft2 for Shear Wall Line Diaphragm Area Load =7.0 psf see Diaphragm Calculations Load from SW Line above =0 lb for Shear Wall Line Linear Shear Wall Load, w =Vu /bs =252 plf Use TYPE A Shear Wall Aspect Ratio Applied Seismic Shear Resistance, φVs =440 plf see Shear Wall Capacity Calcs DCR=Vu/φVs =0.573 <1 Satisfactory Deflection Calculation use 4x4 DF-L No.2 end posts minimum Elastic Modulus of End Posts, E = 1600000 psi End Post Cross-Sectional Area, A =12.25 in2 Apparent Shear Wall Stiffness, Ga =13.0 kips/in Anchorage Elongation, Δa =0.065 in Shear Wall Deflection, δ sw =0.275 in ANSI/AWC SDPWS-2015 (4.3-1) Holdown Design Roof Ceiling Ext. Wall DL, psf 15 10 17 WT, ft 5 5 8.0 Du = (0.9-0.2SDS)D = 179 plf Post Compression Load, C=hw = 2017 lb Holdown Tension Load from SW above =0 lb Strap, lb Load 1590 Provide S 75% Holdown Reduction applied Capacity 4913 see Holdown Capacity Calcs DCR 0.324 Satisfactory 1590 G 3294 0.483 Holdowns Footing, lb Lateral Load Resisting System Design (Cont.) Vertical Diaphragm Design Roof Shear Walls Loading Case 1 Shear Wall 1.4 (S-1.4) Blocked Panel Segmented Shear Wall Length, bs =13.75 ft Height, h =8.0 ft h/bs Ratio =0.6 ≤2:1 Satisfactory, No Reduction Req-d Aspect Ratio Factor, (WPS) = 1.0 ANSI/AWC SDPWS-2015 4.3.4.2 Tributary Area, AT =340 ft2 for Shear Wall Line Diaphragm Area Load =7.0 psf see Diaphragm Calculations Load from SW Line above =0 lb for Shear Wall Line Linear Shear Wall Load, w =Vu /bs =173 plf Use TYPE A Shear Wall Aspect Ratio Applied Seismic Shear Resistance, φVs =440 plf see Shear Wall Capacity Calcs DCR=Vu/φVs =0.392 <1 Satisfactory Deflection Calculation use 4x4 DF-L No.2 end posts minimum Elastic Modulus of End Posts, E = 1600000 psi End Post Cross-Sectional Area, A =12.25 in2 Apparent Shear Wall Stiffness, Ga =13.0 kips/in Anchorage Elongation, Δa =0.006 in Shear Wall Deflection, δ sw =0.112 in ANSI/AWC SDPWS-2015 (4.3-1) Holdown Design Roof Ceiling Ext. Wall DL, psf 15 10 17 WT, ft 5 5 8.0 Du = (0.9-0.2SDS)D = 179 plf Post Compression Load, C=hw = 1380 lb Holdown Tension Load from SW above =0 lb Strap, lb Load 147 Provide S 75% Holdown Reduction applied Capacity 4913 see Holdown Capacity Calcs DCR 0.030 Satisfactory Holdowns Footing, lb 147 G 3294 0.044 Lateral Load Resisting System Design (Cont.) Vertical Diaphragm Design Roof Shear Walls Loading Case 1 Shear Wall 1.5 (S-1.5) Blocked Panel Segmented Shear Wall Length, bs =6.00 ft Height, h =8.0 ft h/bs Ratio =1.3 ≤2:1 Satisfactory, No Reduction Req-d Aspect Ratio Factor, (WPS) = 1.0 ANSI/AWC SDPWS-2015 4.3.4.2 Tributary Area, AT =340 ft2 for Shear Wall Line Diaphragm Area Load =7.0 psf see Diaphragm Calculations Load from SW Line above =0 lb for Shear Wall Line Linear Shear Wall Load, w =Vu /bs =250 plf Use TYPE A Shear Wall Aspect Ratio Applied Seismic Shear Resistance, φVs =440 plf see Shear Wall Capacity Calcs DCR=Vu/φVs =0.567 <1 Satisfactory Deflection Calculation use 4x4 DF-L No.2 end posts minimum Elastic Modulus of End Posts, E = 1600000 psi End Post Cross-Sectional Area, A =12.25 in2 Apparent Shear Wall Stiffness, Ga =13.0 kips/in Anchorage Elongation, Δa =0.058 in Shear Wall Deflection, δ sw =0.240 in ANSI/AWC SDPWS-2015 (4.3-1) Holdown Design Roof Ceiling Ext. Wall DL, psf 15 10 17 WT, ft 5 5 9.0 Du = (0.9-0.2SDS)D = 191 plf Post Compression Load, C=hw = 1997 lb Holdown Tension Load from SW above =0 lb Strap, lb Load 1424 Provide S 75% Holdown Reduction applied Capacity 4913 see Holdown Capacity Calcs DCR 0.290 Satisfactory G Footing, lb Holdowns 3294 0.432 1424 Lateral Load Resisting System Design (Cont.) Vertical Diaphragm Design Roof Shear Walls Loading Case 1 Shear Wall 1.6 (S-1.6) Blocked Panel Segmented Shear Wall Length, bs =3.50 ft Height, h =9.0 ft h/bs Ratio =2.6 >2:1 Reduction Required Aspect Ratio Factor, (WPS) = 0.9 ANSI/AWC SDPWS-2015 4.3.4.2 Tributary Area, AT =340 ft2 for Shear Wall Line Diaphragm Area Load =7.0 psf see Diaphragm Calculations Load from SW Line above =0 lb for Shear Wall Line Linear Shear Wall Load, w =Vu /bs =250 plf Use TYPE A Shear Wall Aspect Ratio Applied Seismic Shear Resistance, φVs =440 plf see Shear Wall Capacity Calcs DCR=Vu/φVs =0.611 <1 Satisfactory Deflection Calculation use 4x4 DF-L No.2 end posts minimum Elastic Modulus of End Posts, E = 1600000 psi End Post Cross-Sectional Area, A =12.25 in2 Apparent Shear Wall Stiffness, Ga =13.0 kips/in Anchorage Elongation, Δa =0.078 in Shear Wall Deflection, δ sw =0.394 in ANSI/AWC SDPWS-2015 (4.3-1) Holdown Design Roof Ceiling Ext. Wall DL, psf 15 10 17 WT, ft 5 5 9.0 Du = (0.9-0.2SDS)D = 191 plf Post Compression Load, C=hw = 2247 lb Holdown Tension Load from SW above =0 lb Strap, lb Load 1913 Provide S 75% Holdown Reduction applied Capacity 4913 see Holdown Capacity Calcs DCR 0.389 Satisfactory0.581 G 3294 Holdowns Footing, lb 1913 ID Simpson Holdown Anchor Bolt Dia (in) Stem Wall Min Width (in) Anchor Bolt2 Min Embed into Stem Wall (in) Min Embed into Footing (in) Clear Edge Dist inside footing (in) 4" Wall Post5 6" Wall Post5 LRFD Allowable Load 4x (lbs)3 LRFD Allowable Load 6x (lbs)3 A HDU2 5/8 6 SSTB 16 12 5/8 N/A N/A 4x4 4x6 2732 2732 B HDU4 5/8 6 SSTB20 16 5/8 N/A N/A 4x4 4x6 3171 3171 C HDU5 5/8 6 SSTB 24 20 5/8 N/A N/A 4x4 4x6 3562 3562 D HDU8 7/8 8 SSTB 28 24 7/8 N/A N/A 4x6 4x6 6851 6851 E HDU11 1 8 PAB8 FULL 11 16.5 4x8 6x6 10216 10216 F HDU14 1 8 PAB8 FULL 11 16.5 4x8 6x6 14250 15476 P HD19 1.125 8 PAB9 FULL 13.5 20.5 4x8 6x6 14250 20432 ID Simpson Holdown Anchor Bolt Dia (in) Stem Wall Min Width (in) Anchor Bolt4 Min Embed into Stem Wall (in) Min Embed into Footing (in) Clear Edge Dist inside footing (in) 4" Wall Post5 6" Wall Post5 LRFD Allowable Load 4x (lbs)3 LRFD Allowable Load 6x (lbs)3 G HDU2 5/8 6 SSTB 16 12.625 N/A N/A 4x4 4x6 3294 3294 H HDU4 5/8 6 SSTB20 16.625 N/A N/A 4x4 4x6 4891 4891 I HDU5 5/8 6 SSTB 24 20.625 N/A N/A 4x4 4x6 5500 6048 J HDU8 7/8 8 SSTB 28 24.875 N/A N/A 4x6 4x6 7467 7467 K HDU11 1 8 PAB8 FULL 11 16.5 4x8 6x6 10216 10216 L HDU14 1 8 PAB8 FULL 11 16.5 4x8 6x6 14250 15476 P HD19 1.125 8 PAB9 FULL 13.5 20.5 4x8 6x6 14250 20432 ID Simpson Holdown Anchor Bolt Dia (in) Stem Wall Min Width (in) Simpson Epoxy Min Embed into Stem Wall (in) Min Embed into footing (in)4 Clear Edge Dist inside footing (in) 4" Wall Post5 6" Wall Post5 LRFD Allowable Load 4x (lbs)3 LRFD Allowable Load 6x (lbs)3 M HDU2 5/8 6 SET-XP N/A 12.5 N/A 4x4 4x6 3294 3294 N HDU5 5/8 6 SET-XP N/A 14 N/A 4x6 4x6 6048 6048 O HDU8 7/8 6 SET-XP N/A 20 N/A 4x6 4x6 7467 7467 ID Simpson Holdown Anchor Bolt Dia (in) Stem Wall Min Width (in) Anchor Bolt2 Min Embed into Stem Wall (in) Min Embed into Footing (in) Clear Edge Dist inside footing (in) 4" Wall Post5 6" Wall Post5 LRFD Allowable Load 4x (lbs)3 LRFD Allowable Load 6x (lbs)3 Q HDU11 1 8 PAB8 FULL 11 16.5 4x8 6x6 10001 10001 R HDU14 1 8 PAB8 FULL 11 16.5 4x8 6x6 14250 15476 P HD19 1.125 8 PAB9 FULL 13.5 20.5 4x8 6x6 14250 20432 ID Simpson Holdown Anchor Bolt Dia (in) CMU Wall Min Width (in) Anchor Bolt2 Min Embed into CMU Wall (in) Min Embed into Footing (in) Min End Distance (in) 4" Wall Post5 6" Wall Post5 LRFD Allowable Load 4x (lbs)3 LRFD Allowable Load 6x (lbs)3 Am HDU2 5/8 8 SSTB16 12 5/8 N/A 4 1/4 4x4 4x6 1742 1742 Ac HDU2 5/8 8 SSTB16 12 5/8 N/A 4 1/4 4x4 4x6 3294 3294 Dm HDU8 7/8 8 SSTB28 24 7/8 N/A 38 4x6 4x6 4285 4285 Dc HDU8 7/8 8 SSTB28 24 7/8 N/A 38 4x6 4x6 5978 5978 ID S T U V W Notes: 1 Load and Resistance Factor Design. 2 Minimum end distance shall be 5". 3 Minimum end distance shall be 4". 4 5 Post maximum height of 10.0 ft. (2) CMST12 20" 50-16d 6 19746 Overal concrete footing depth shall be 5D deeper than CMST12 33" 74-16d 3.5 9873 (2) CMST14 26" 56-16d 6 13907 CMSTC16 20" 50-16d 3.5 4913 CMST14 26" 56-16d 3.5 6954 Underpinning Existing Footing Holdown into CMU Wall Strap Holdowns Simpson Strap End Length Fastners (ea end )Min Column Width (in)Allowable Tension Load (lbs)1 Epoxy into Existing Footing HOLDOWN SCHEDULE Raised Foundation Slab on Grade ID Simpson Holdown Anchor Bolt Dia (in) Square Washer Side Size (in) Anchor Bolt2 Stiffness Plate Thickness (in) Stiffness Pl. Weld Size (in) Min. Nailer Size 4" Wall Post5 6" Wall Post5 Allowable Tension (lb)1 A HDU4 5/8 0.375 PAB5 1/4 1/4 2x 4x4 4x6 4565 B HDU5 5/8 0.4 PAB5 1/4 1/4 2x 4x4 4x6 5645 C HDU8 5/8 0.625 PAB7 1/4 1/4 3x 4x4 4x6 6970 D HDU8 7/8 0.625 PAB7 1/4 1/4 3x 4x6 4x6 7870 E HDU11 1 0.875 PAB8 3/8 5/16 3x N/A 6x6 9535 F HDU14 1 1.125 PAB8 3/8 5/16 3x N/A 6x6 14445 ID Simpson Holdown Anchor Bolt Dia GrD. 36 (in) Stem Wall Min Width (in) Anchor Bolt2 Min Embed into 10" Concrete Wall (in) Min Embed into 12" Concrete Wall (in) Clear Edge Dist inside footing (in) 4" Wall Post5 6" Wall Post5 Allowable Tension (lb)1 G HDU2 5/8" N/A PAB5 18" 18" N/A 4x4 4x6 3296 H HDU4 5/8" N/A PAB5 18" 18" N/A 4x4 4x6 4893 I HDU5 5/8" N/A PAB5 18" 18" N/A 4x4 4x6 6077 J HDU8 7/8" N/A PAB7 18" 18" N/A 4x8 4x6 8456 K HDU11 1" N/A PAB8 18" 18" 16.5 N/A 6x6 10219 L HDU14 1" N/A PAB8 21" 18" 16.5 N/A 6x6 15422 M HD12 1-1/8" 6 PAB9 22" 18" N/A N/A 4x6 16623 N HD19 1-1/4" 6 PAB10 27" 24" N/A 4x8 4x6 20749 O 2x-HDU14 (2)-1" 6 (2) PAB10 42" 42" N/A N/A 6X6 30845 ID Simpson Holdown Anchor Bolt Dia (in) PL Washer Size & Thickness Anchor Bolt2 Allowable Tension @ Away From Edge (lb) P HDU8 7/8" 2"-3/8" PAB7 8456 Q HDU11 1" 2"-3/8" PAB8 10219 R HDU14 1" 2"-3/8" PAB8 15422 X HD12 1-1/8" 2.5"-3/8" PAB9 16623 Y HD19 1-1/4" 3"-3/8" PAB10 20749 Z 2x-HDU14 (2)-1" 2"-3/8" (2) PAB10 30845 Notes: 1 Load and Resistance Factor Design. S CMSTC16 20" 50-16d 3.5 2 Minimum end distance shall be 5". T CMST14 26" 56-16d 3.5 3 Minimum end distance shall be 4". U CMST12 33" 74-16d 3.5 4 V (2) CMST14 26" 56-16d 6 5 Post maximum height of 10.0 ft. W (2) CMST16 20" 50-16d 6 19746 See Sheet SA1 30845 Holdowns Schedule (SW on Beam with strap) ID Simpson Strap End Length Fastners (ea end ) Min Column Width (in)Allowable Tension Load (lbs)1 4913 6954 9873 Overal concrete footing depth shall be 5D deeper than anchor embendment. 13907 See Sheet SA1 16623 See Sheet SA1 20749 See Sheet SA1 10219 See Sheet SA1 15422 HOLDOWN SCHEDULE Steel Beam HOLDOWN ANCHOR IN CONCRETE WALL 12" Thick Slab Podium Anchorage Design Table Min Embed into Slab (in)Allowable Tension @ 13" From Edge (lb) See Sheet SA1 8456 Lateral Load Resisting System Design (Cont.) Type Sheathing/ Nailing Grade A35/LTP4 Spacing (in) 16d Nail Spacing (in) 1/4" SDS LAG Spacing (in) 5/8" Anchor Bolt Spacing (in) Resistance (plf) Type A 15/32" w/8d nails @6-6-12 Structural I 22.0 8.0 14.0 48.0 440 Type B 15/32" w/10d nails @6-6-12 Structural I 18.0 6.0 11.0 48.0 540 Type C 15/32" w/10d nails @4-4-125 Structural I 12.0 4.0 7.0 32.0 810 Type D 15/32" w/10d nails @3-3-125 Structural I 9.0 3.0 5.0 25.0 1060 Type E 15/32" w/10d nails @2-2-125 Structural I 7.0 2.0 4.0 19.0 1390 Type F Double Sided 15/32" w/10d nails @3-3-124,5,8 Structural I 4.0 n/a 3.0 12.0 2100 Type G Double Sided 15/32" w/10d nails @2-2-124,5,8 Structural I 3.0 n/a 2.0 11.0 2750 Panel All. Load (plf) A35/LTP4 Spacing (ft) 16d Nail Spacing (in) 1/4" SDS LAG Spacing (in) 5/8" Anchor Bolt Spacing (ft) Type A Req-d Spacing (ft)/ panel all load (plf)= 448 1.85 0.68 1.20 5.05 DCR = 0.98 0.99 0.98 0.97 0.79 Type B Req-d Spacing (ft)/ panel all load (plf)= 544 1.50 0.55 0.98 4.11 DCR = 0.99 1.00 0.91 0.94 0.97 Type C Req-d Spacing (ft)/ panel all load (plf)= 816 1.00 0.37 0.65 2.74 DCR = 0.99 1.00 0.91 0.89 0.97 Type D Req-d Spacing (ft)/ panel all load (plf)= 1064 0.77 0.28 0.50 2.09 DCR = 1.00 0.98 0.89 0.84 0.99 Type E Req-d Spacing (ft)/ panel all load (plf)= 1392 0.58 0.21 0.38 1.60 DCR = 1.00 1.00 0.78 0.88 0.99 Type F Req-d Spacing (ft)/ panel all load (plf)= 2128 0.39 n/a 0.25 1.06 DCR = 0.99 0.86 n/a 0.99 0.95 Type G Req-d Spacing (ft)/ panel all load (plf)= 2784 0.30 n/a 0.19 0.81 DCR = 0.99 0.85 n/a 0.87 1.14 Capacity = varies 580 141 250 1050 KF (NDS Table 10.3.1) =n/a n/a 3.32 3.32 3.32 φ (NDS Table 10.3.1) = n/a n/a 0.65 0.65 0.65 λ (NDS Table N3) = n/a n/a 1.0 1.0 1.0 Geometry Factor, CΔ (NDS Table 11.5.1A) =n/a n/a 1.0 1.0 1.0 Bolt/Screw Diameter, D = n/a n/a 0.192 0.25 0.625 Min Edge Distance =4D = n/a n/a 0.768 1 2.5 Min Embedment = n/a n/a 1.5 2.0 n/a Res Factor, φD (AWC SDPWS Sec. 4.3.3) = 0.80 n/a n/a n/a n/a Convert from ASD to LRFD = - 0.7 - - - safety factory for ductile failure = n/a 100% 98% 98% 98% Allowable Load = varies 812 298 529 2221 Shearwall Capacities Notes: 1. Lumber shall be DF-L with Specific Gravity of 0.50 min. All panel edges shall be fastened to 2-inch nominal or wider framing. 2. Framing members receiving edge nailing from abutting panels shall not be less than a single 3x stud or wider nominal. All wood structural panel joint and sill plate nailing shall be staggered at all panel edges. Nails shall be placed not less than 1/2" edge distance from the panel edges and 3/8" from the edge of the connecting members. 3. Min two bolts per piece of sill plate and one located within 12" of each end of each sill plate. Placement of lag bolts: Min edge distance shall be (1.5)(bolt diameter); Min end distance shall be (7)(bolt diameter), Min spacing shall be (4)(bolt diameter). Edge distances, end distances and spacing shall be sufficient to prevent splitting of wood. If splitting occurs, notify the engineer for an alternate product. 4. Type I and J shearwalls shall have plywood installed on both sides. Install A35/LTP4 staggered on both sides. Blocking and studs at panel edges shall be min 3x in thickness. 5. Type D, E, F, G, H shearwalls shall have min. 3x studs at panel edges. Special Inspection Required. 6. Plywood Panels may be either OSB, 3 ply, 4 ply or 5 ply plywood, unless specifically identified otherwise on plans. 7. For A35 and LTP4, use (12) 8dx1 1/2" nails. 8. Spacing for A35 and LTP4 may be reduced to max 16" oc if additional A35 and LTP4 are installed along same S/W line to meet the min qty required for the identified spacing multiplied by S/W length. Also, Spacing of A35 and LTP4 may be doubled if placed on both sides of shearwall. USGS web services were down for some period of time and as a result this tool wasn't operational, resulting in timeout error. USGS web services are now operational so this tool should work as expected. 4703 W McFadden Ave, Santa Ana, CA 92704, USA Latitude, Longitude: 33.7395545, -117.9315664 Date 11/14/2024, 10:59:32 AM Design Code Reference Document ASCE7-16 Risk Category II Site Class D - Default (See Section 11.4.3) Type Value Description SS 1.329 MCER ground motion. (for 0.2 second period) S1 0.474 MCER ground motion. (for 1.0s period) SMS 1.594 Site-modified spectral acceleration value SM1 null -See Section 11.4.8 Site-modified spectral acceleration value SDS 1.063 Numeric seismic design value at 0.2 second SA SD1 null -See Section 11.4.8 Numeric seismic design value at 1.0 second SA Type Value Description SDC null -See Section 11.4.8 Seismic design category Fa 1.2 Site amplification factor at 0.2 second Fv null -See Section 11.4.8 Site amplification factor at 1.0 second PGA 0.568 MCEG peak ground acceleration FPGA 1.2 Site amplification factor at PGA PGAM 0.682 Site modified peak ground acceleration TL 8 Long-period transition period in seconds SsRT 1.329 Probabilistic risk-targeted ground motion. (0.2 second) SsUH 1.443 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration SsD 1.865 Factored deterministic acceleration value. (0.2 second) S1RT 0.474 Probabilistic risk-targeted ground motion. (1.0 second) S1UH 0.515 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration. S1D 0.646 Factored deterministic acceleration value. (1.0 second) PGAd 0.767 Factored deterministic acceleration value. (Peak Ground Acceleration) 11/14/24, 10:59 AM U.S. Seismic Design Maps https://www.seismicmaps.org 1/3 Type Value Description PGAUH 0.568 Uniform-hazard (2% probability of exceedance in 50 years) Peak Ground Acceleration CRS 0.921 Mapped value of the risk coefficient at short periods CR1 0.921 Mapped value of the risk coefficient at a period of 1 s CV 1.366 Vertical coefficient 11/14/24, 10:59 AM U.S. Seismic Design Maps https://www.seismicmaps.org 2/3 DISCLAIMER While the information presented on this website is believed to be correct, SEAOC /OSHPD and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in this web application should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. SEAOC / OSHPD do not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the seismic data provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the search results of this website. 11/14/24, 10:59 AM U.S. Seismic Design Maps https://www.seismicmaps.org 3/3 SANTA ANA CITY COUNCIL Mayor vamezcua@santa-ana.org Mayor Pro Tem - Ward 2 bvazquez@santa-ana.org Ward 1 tphan@santa-ana.org Ward 3 jessielopez@santa-ana.org Ward 4 pbacerra@santa-ana.org Ward 5 jryanhernandez@santa-ana.org Ward 6 dpenaloza@santa-ana.org MAYOR Valerie Amezcua MAYOR PRO TEM Benjamin Vazquez COUNCILMEMBERS Phil Bacerra Johnathan Ryan Hernandez Jessie Lopez David Penaloza Thai Viet Phan CITY OF SANTA ANA PLANNING AND BUILDING AGENCY 20 Civic Center Plaza ● P.O. Box 1988 Santa Ana, California 92702 www.santa-ana.org CITY MANAGER Alvaro Nuñez CITY ATTORNEY Sonia R. Carvalho CITY CLERK Jennifer L. Hall April 10, 2025 Nathan Coffee 1245 E. Walnut Street, Also sent via email to: nathan@ncaarchitects.com Suite 112, Pasadena, CA 91106 Subject: Address Assignment for a new attached ADU at 4703 W McFadden Avenue, Unit C (108- 131-37) in Santa Ana, CA 92704 Dear Mr. Coffee, The City of Santa Ana Planning and Building Agency (PBA) is the responsible agency for legal addressing within the City of Santa Ana’s jurisdiction. This letter confirms the address assignment for a new attached ADU at 4703 W. McFadden Avenue, Unit C (108-131-37). Notice is hereby given that the following assigned address(es) shall be posted onsite per the approved address plan, attached hereto as Exhibit A. Address(es) to be Activated/Posted Address(es) to be deactivated 4715 W. McFadden Avenue ( 4717 W. McFadden Avenue ( 1. 4703 W. McFadden Avenue, Unit C (Main To subdivide commercial and/or residential units into multiple units, a building permit (and all other associated permits), plans, and inspection approvals by the PBA are required. Address(es) will be verified during inspections by the Building Safety Division. Please update your records accordingly. Should you have any questions, feel free to contact me by phone at 714-667-2728 or by email at CSantana@santa-ana.org. Sincerely, Cristian Santana Cristian Santana Assistant Planner II Exhibit A – Address Plan Address Letter 4703 W. McFadden Avenue, Unit C Page 2 of 2 c: Kris K Chu, Santa Ana Manager, United States Post Office Fernando Banuelos, Fountain Valley Manager, United States Post Office Yesenia Torres, Santa Ana Manager, United States Post Office Enrique Ponce, Sna-North Grand Sta Manager, United States Post Office Esthephany Treto Ramirez, Admin Supervisor, United States Post Office Chris Tuiolosega, United States Post Office Alex Alvarez, Santa Ana Postmaster, United States Post Office Federal Express, Administration Cathy Joseph, Garden Grove Unified School District Christine Hy, Garden Grove Unified School District Cathy Slader, Orange Unified School District Ted Walstrom, Santa Ana Unified School District Jeremy Cogan, Santa Ana Unified School District Yvette Miranda, Santa Ana Unified School District Cristina Bernal, Tustin Unified School District Orange County Fire Authority Neal Kelly, Registrar of Voters Members, Board of Supervisors Southern California Gas Company Southern California Edison Company Claude Parrish, County Assessor's Office GIS SAG, AT&T UPS, Administration City Manager’s Office Beverly Martin, Police Community Services Specialist Boris Duran, Police Systems Manager Jennifer Arellano, Police Communications Manager Chris Hubbard, Police Systems Support Analyst Alejandra Gutierrez, Treasury & Customer Services Manager Hector Jimenez, Revenue Supervisor Alfonso Chavez, Utilities Customer Services Supervisor Judson Brown, Housing Division Manager Rudy Rosas, Deputy Public Works Director / City Engineer Zdenek (Zed) Kekula, Principal Civil Engineer Jason Kwak, Building Safety Manager Evelyn LaRocca, Permit Services Principal Kathy Hernandez, Permit Technician Julie Amsden, Permit Technician Ricardo Soto, Acting Planning Manager Jerry Guevara, Senior Planner Yvette Portugal, Code Enforcement Manager Jerry Navarro, Code Enforcement Principal GSPublisherVersion 0.0.100.100 4 7 0 3 W M C F A D D E N A V E , U N I T C , S A N T A A N A , CA 9 2 7 0 4 N E W A D D I T I O N T O N E W A D U sheet title: sheet number: REVISIONS NO.DATE DESCRIPTION DESIGN DRAWN ISSUED APPROVED NS JT AS 1 .1 PROPOSED ARCHITECTURAL SITE PLAN N&NC 12 4 5 EA S T W A L N U T S T R E E T , ST E 11 2 PA S A D E N A , CA 91 1 0 6 4' - 8 " 77 ' - 1 0 " 34'-3"12'-5"18'-8"3'19'-7" 34'-3"34'-1"19'-7" 3' - 1 0 " 15 ' - 7 " 29 ' - 1 1 " 6' - 6 " 26 ' - 8 " 3' - 1 0 " 45 ' - 6 " 33 ' - 2 " 33'-9" 3" 54' 33'-9"34'-1"20'-2" 4' 15 ' - 7 " 29 ' - 1 1 " 6' - 6 " 26 ' - 6 " 34'14' 3" 13'-9" 4' - 4 " 15 ' - 7 " 10 ' - 1 " 4' - 8 " 15 ' - 2 " 6' - 6 " 26 ' - 2 " 82 ' - 6 " 82 ' - 6 " 10'10' 34'-2"12'-5"18'-8"3'19'-10" 4' 1' - 1 " NEW COVER PERGOLA PORCH: 66 SQ.FT. (E) SFR: 868 SQ.FT. (E) FE N C E (E) FENCE(E) FENCE(E) FENCE(E) FENCE (E) FE N C E (E) FE N C E (E) FE N C E (E) FE N C E (E) FE N C E (E) FE N C E (E) FE N C E (E) CONCRETE (E) CONCRETE (E) CONCRETE (E) LANDSCAPE (E) LANDSCAPE (E) LANDSCAPE (E) LANDSCAPE (E) LANDSCAPE (E) LANDSCAPE PL 82 .5' W C A M I L L E S T 5% SL O P E 5% SL O P E 5% SL O P E 5% SLOPE 5% SLOPE 5% SLOPE 2% SLOPE 2% SL O P E 2% SL O P E 2% SL O P E 2% SL O P E 2% SLOPE W WA T K I N S W A Y S SAFFORD ST 2% SL O P E 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE 2% SLOPE PL 82 .5' PL 88' PL 88' NEW ADU UNIT 2 680 SQ.FT. 10 ' WI D E EA S E M E N T FO R P I P E L I N E S SETBACK WH HEAT PUMP TANKLESS 1' WIDE EASEMENT SITE INFORMATION: GENERAL NOTES: 1. NO BASEMENT ON LOT 2. LANDSCAPING IS EXISTING TO REMAIN UNLESS OTHERWISE NOTED ON THE SITE PLAN 3. ALL TREES ARE EXISTING TO REMAIN LANDSCAPING NOTES: 1. EXISTING LANDSCAPING AND IRRIGATION CONTROLLER TO REMAIN DRAINAGE NOTES: 1. PROVISIONS SHALL BE MADE FOR CONTRIBUTORY DRAINAGE AT ALL TIMES 2. OWNER WILL MAINTAIN DRAINAGE DEVICES AND KEEP FREE OF DEBRIS. 3. AN EXCAVATION / ENCROACHMENT PERMIT IS REQUIRED FOR CONSTRUCTION AND/OR DISCHARGE OF DRAINAGE WITHIN PUBLIC ROAD R/W. 4. NO WORK IS ALLOWED WITHIN THE PROTECTED ZONE LOF TREES WITHOUT A TREE REPORT AND PERMIT 5. FINISHED FLOOR TO BE 8 INCHES ABOVE FINISHED GRADE 6. LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6" WITHIN THE FIRST 10FT (5% SLOPE). WHERE LOT LINES WALLS, SLOPES OR OTHER PHYSICAL BARRIER PROHIBITS 6" FALL WITHIN 10 FT, DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. [CRC R401.3, CBC 1804.4] 7. IMPERVIOUS SURFACES WITHIN 10 FT OF THE BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2% AWAY FROM THE BUILDING . [CRC R401.3 EXCEPTION, CBC 1804.4] LEGEND: (N) ADU CONCRETE LANDSCAPE SHED PERGOLA PORCH COVER PERGOLA (N) NEW ADDITION (E) TREE SITE INFORMATION: APN 0108-013-039 ADDRESS: 4703 W MCFADDEN AVE, UNIT C, SANTA ANA , CA 92704 LEGAL DESCRIPTION : TRACT NO. 10558, M.B. 448 - 24/25 LOT AREA: 7260 EXISTING HOUSE AREA: 868 SQUARE FEET EXISTING COVERED PORCH: 66 SQUARE FEET EXISITING LOT COVERAGE: 934 SQ. FT. OR 12.8% PROPOSED ATTACHED ADU: 680 SQ. FT. PROPOSED LOT COVERAGE: 1614 SQ. FT. OR 22.2% ALL NEW UTILITIES WILL BE UNDERGROUND PER SAMC SECTION 41-626 - 1 /8 " = 1 '-0 " 1 PROPOSED ARCHITECTURAL SITE PLAN SCALE : NO R T H 4715 W. McFadden Avenue 4717 W. McFadden Avenue Exhibit A O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Submittal Criteria Form Required for Single Family or Duplex Residences (Use Commercial form for lots with 3+ dwelling units or new residential tracts) Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification. Project Information  New Single Family Residence/Duplex  Addition/Remodel  ADU  Other Address: Unit #: City or Unincorporated County Area: ZIP: Scope of Work: Existing Area to Total Resulting Stories: Area Added in Past 2 Years Yes No Questionnaire OCFA Plan Type if “Yes” 1.   New – Is this a new single family residence or duplex? *(PR160) Residential Site with Water Availability 2.   ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has (PR400-402) Fire Sprinkler   Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire sprinkler retrofit based on a threshold set by local ordinance? (PR400-402) Fire Sprinkler 4.   Distance – Is the most remote portion of the addition, ADU or other detached structure greater than *(PR160) Residential Site 5.   Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non- sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all *(PR160) Residential Site with Water Availability 6.   Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed (PR400-402) Fire Sprinkler   Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold *(PR160) Residential Site (PR400-402) Fire Sprinkler 8.   Gate – Is a gate being installed across a driveway or road that is designated as a fire department access roadway, or a driveway or road that serves more than a single home/duplex? (PR180) Gate 9.   Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000 *(PR160) Residential Site *(PR172-174) Methane Test/Mitigation Plans 10.   Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation, or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as *(PR125) Fuel Modification (PR182) Accessory Structure *OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals. Applicant Certification I certify, under penalty of perjury, under the laws of the State of California, that the information above is true: Print Name:_______________________________________ Signature:___________________________________________ Date:______________ Phone Number:_____________________________________________ Email:_____________________________________________________________ Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required. ______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes” and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination. For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-610 8 SFR O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City Official Requesting Review: City Reference #: __________________________ City / County: _____________________________________ Date: __________________________________ Contact Name: _____________________________________ E-Mail: __________________________________ Title: _____________________________________ Phone #: _________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County: OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ Updated: 08/30/2021 0 10 AV Ov — 400 -.04 0 VI S.0 46 .10 or RI -.low 4�' A- Al IP V. _4dW_. -at -VO. .W46. 10 Are 40, V op P %L 0 do OF Opp a J), 614 IF XA ri Cio-P vi If er bt L It �,O z 0, .. a f.0, !771 ;z,. is #0 4 8. 0 IL 0 dip T4 L)evelope A Plice 4 11 4.drl ress L4 111!5 Aft ZIM101216121W Prole o1WW1119 INUITIDer U nf Reside Numuer 01 nf Comme 619MIN Iry �)er ( I �Iml I IFAV� Y' ,A, "AA A", "A a M me In' yr ;.I- In— )quare ree al snace :>quare ree N.%Iial and IACP M, i A W41P Aft I i Grove Unified School DIS artification of Co pliance nent of School Faci i y eE It F <1 W q L Mod City Int. School Hiah Schoc IF W D I �11�; �A Fhe to tootage true, Developer/Applica above representations as square are ater determined that such representations are not true then this certificate erminniop. a qnd the ;;nnronriate Citv/Countv sh211 be notified. o�ppiicant ic.. pursuant to mithin 5)0 de^j lereli overi frnn 9FW1 N ioucea inat any paity ant Code Section 659c P nqvment of the fee. ing a protes- and FIducatic ;Rp.rpint ot Pdq dft eYaFU1HY 1Ht PM% ,-,ode Sentior 4% 1P V 'A Ll 4 agrees Inal 11 it 1211 automatic,�; position 01 lueti 620 must do se rffAWV"AWP�P"_ VA�Abwfaff "00?31MViT*"o ",W hi's ce ifies ha the aboveamnamed Developer/Applicant has paid school taclilt, :D pliance with Govern ent Code Section 65995 and Education Code Section 1762C hese fee have been received fro 0140 MENOMONIE $ Agg MOP, Bank 0 ,ash Check Check Na. AA a e Su erintendent Desi nee Garden Grove Unified S ool Dist (714) 6663uar,449 11 W] N 19 Rol Wlhgf �Wm WOOM Ed "IMY40k P T A7, *4 jib 'oI -4, 41 . 1V I e. --,"I op. Oldho'-Z MW or _14 �4. jpI *.0 Iwo VA" lo &46— d1b 4'1 41, 41L NI .4 Page 1 of 1 EXISTING ONE & TWO FAMILY DWELLINGS ELECTRICAL SERVICES UNDERGROUND EXCEPTION CEC 2022 ELC-04 All new utility connections are required to be installed below grade by Santa Ana Municipal Code 41- 626(b). There is a standing exception for one and two family dwellings. This exception applies only when the new electrical service is designed to be fed from below grade as well as overhead. This diagram is a typical unit. The utility is able to feed this cabinet from the top or the bottom without interfering with the distribution wiring. All the circuit breakers and branch circuits are contained in the circuit breaker side of this cabinet. Only listed combination overhead and underground feed service boxes may be used to connect to an overhead utility drop. This exception to an underground fed service applies only to existing single family and two family residences. Planning & Building Agency Permits & Plan Check Section 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 Rigid Conduit Service Entrance Conductor Riser Underground Service Lateral METER Rev. 1/21/2020