Loading...
HomeMy WebLinkAbout2100 E Wellington Ave - REV 1 - PlanPAGE REV: A1 10/6/2024 EFREN LUMBRERAS 2100 E WELLINGTON AVE, SANTA ANA, CA, 92701 PROJECT NUMBER: 109R-100LUMB SHEET DESIGNER: HIMANSHU VASHIST CUSTOMER RESIDENCE: TEL. (949) 763-0025 APN: 400-153-29 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 COVER SHEET SCOPE OF WORK GENERAL NOTES PV-1.0 VICINITY MAP LTD: LR5-54HABB-400M SNR-DC-00450 1707000-XX-Y (MCI) ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE #SSTAMPCS #ESTAMPCS ABBREVIATIONS A AMPERE AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT (E)EXISTING ESS ENERGY STORAGE SYSTEM MSP MAIN SERVICE PANEL (N) NEW PRE-FAB PRE-FABRICATED PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS V VOLTS W WATTS SHEET INDEX PAGE # DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-2.1 ESS ELEVATION VIEW PV-3.0 LAYOUT PV-3.1 MOUNTING DETAIL PV-4.0 ELECTRICAL PV-4.1 ELECTRICAL CALCS PV-4.2 BACKUP LOAD CALCS PV-4.3 PANEL SCHEDULE PV-5.0 SIGNAGE PV-5.1 SIGNAGE NOTE: CEC 2022: 705.12(B)(3)(3): THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR. CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.41(A). MODULES, ARE CLASS A FIRE RATED. CONDUCTORS OUTSIDE OF THE ARRAY ARE LIMITED TO LESS THAN 30V IN 30 SECONDS AND CEC 2022 690.12(B)(2)(2) WHERE CONDUCTORS INSIDE THE ARRAY BOUNDARY IS LIMITED TO LESS THAN 80V IN 30 SECONDS ROUTINE MAINTENANCE. SYSTEM VOLTAGE IN ACCORDANCE WITH CEC 706.20 AND EXCEPTION 1 CEC 706.20 (B). CIRCUITS FROM THESE TERMINALS PASS THROUGH A WALL OR PARTITION PER 706.15(D). CIRCUIT WIRING IS EXTENDED MORE THAN 6FT AND DOES NOT INCLUDE ANY ADDITIONAL OUTLETS OR DEVICES PER CEC 210.12(D). GREATER THAN THE LOAD POSED BY THE SINGLE LARGEST UTILIZATION EQUIPMENT CONNECTED TO THE SYSTEM PER CEC ARTICLE 710.15(A) 31707000-XX-Y, 13.5 KWH. ***The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. *** Bldg#: 101121230 Elec#: 20184282 Approvals: Elec: M Smith 2100 E Wellington Ave11/18/2024 PAGE REV: A1 10/6/2024 EFREN LUMBRERAS 2100 E WELLINGTON AVE,  SANTA ANA, CA, 92701 PROJECT NUMBER:   109R-100LUMB SHEET DESIGNER: HIMANSHU VASHIST CUSTOMER RESIDENCE: TEL. (949) 763-0025 APN: 400-153-29 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 PL PL PL PL PL PL PLPL PL PL PL PL SITE PLAN PV-2.0 #SSTAMPSP #ESTAMPSP NOTES:  RESIDENCE DOES NOT CONTAIN ACTIVE FIRE  SPRINKLERS. ARRAY DETAILS:  TOTAL ROOF SURFACE AREA: 2500 SQFT.  TOTAL PV ARRAY AREA: 210.2 SQ FT.  PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE  AREA) * 100 = 8.4% ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS  IN ACCORDANCE WITH R328.4. ESS UNITS SHALL BE  SEPARATED FROM EACH OTHER BY NOT LESS THAN 3 FEET  EXCEPT WHERE SMALLER SEPARATION DISTANCES ARE  DOCUMENTED TO BE ADEQUATE BASED ON LARGE/SCALE  FIRE TESTING. SITE PLAN - SCALE = 0'-0 1/16" = 1'-0" (E) RESIDENCE (N) ARRAY AR-01 FIRE SETBACKS (18" TYP) ROOF PATHWAYS (3' TYP) SE MP E WELLINGTON AVE ROOF PATHWAYS (3' TYP) GPMD ACINV (E) FENCE (E) CHIMNEY (E) GATE(TYP.) A AA A A A A A AA GENERATION PANEL RAIL STANDOFFS &  FOOTINGS SOLAR  MODULES SOLAREDGE METER AC DISCONNECT(S) PM SE MP MAIN PANEL SERVICE ENTRANCE  SCALE: NTS NOTE: NOT ALL ITEMS IN LEGEND  WILL APPEAR IN SITE PLAN LEGEND SM INV INVERTER(S) AC DC DISCONNECT(S)DEDICATED PV METER DC SUB-PANELSP LC PV LOAD CENTER SEM BACKUP LOADS PANEL BACKUP INTERFACE MICROGRID  INTERCONNECT DEVICE AM ENERGY STORAGE  SYSTEM METER ADAPTER MD BP MA BIACREL METER ELECTRIC VEHICLE  SUPPLY EQUPMENTEV CB IQ COMBINER BOX  1 COMMUNICATION  WIRES GROUNDING  ELECTRODE BACKUP GATEWAY GP BG POWERWALL ENERGY  STORAGE SYSTEM (ESS) INTERIOR EQUIPMENT  SHOWN AS DASHED EXTERNAL RAPID SHUTDOWN SWITCH RSD ARRAY  PITCH PV AREA  (SQFT) AR-01 17° 210.2 TRUE  AZIM MAG  AZIM 259°271° Signed 10/6/2024 2100 E Wellington Ave11/18/2024 PAGE REV: A1 10/6/2024 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 EFREN LUMBRERAS 2100 E WELLINGTON AVE,  SANTA ANA, CA, 92701 PROJECT NUMBER:   109R-100LUMB SHEET DESIGNER: HIMANSHU VASHIST CUSTOMER RESIDENCE: TEL. (949) 763-0025 APN: 400-153-29 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 PV-2.1 GATE EXTERIOR SOUTH WALL MSP GPBG ACD SITE PLAN - SCALE = NTS ESS ELEVATION VIEW ESS ELEVATION VIEW PW3 ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS IN ACCORDANCE WITH R328.4.   ESS UNITS SHALL BE SEPARATED FROM EACH OTHER BY NOT LESS THAN 3 FEET EXCEPT  WHERE SMALLER SEPARATION DISTANCES ARE DOCUMENTED TO BE ADEQUATE BASED ON  LARGE/SCALE FIRE TESTING. NO DWELLING DOORS OR WINDOWS ARE IN  NEARBY Signed 10/6/2024 2100 E Wellington Ave11/18/2024 PAGE REV: A1 10/6/2024 EFREN LUMBRERAS 2100 E WELLINGTON AVE,  SANTA ANA, CA, 92701 PROJECT NUMBER:   109R-100LUMB SHEET DESIGNER: HIMANSHU VASHIST CUSTOMER RESIDENCE: TEL. (949) 763-0025 APN: 400-153-29 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 #SSTAMP DESIGN CRITERIA MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF WIND SPEED:  96 MPH 3-SEC GUST. FASTENERS: (4) #14 S.S. SEALING WASHER  WOOD SCREWS FULLY  PENETRATING THROUGH WOOD  DECK PV-3.0 LAYOUT SOLAR MODULE SNAPNRACK  RACKING 6" MODULE ELEVATION DETAIL - SCALE: NTS INSTALLERS SHALL NOTIFY ENGINEER OF ANY  POTENTIAL STRUCTURAL ISSUES OBSERVED  PRIOR TO PROCEEDING W/ INSTALLATION. * IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12"  BOUNDARY REGION OF ANY ROOF PLANE  EDGES (EXCEPT VALLEYS), THEN  ATTACHMENTS NEED TO BE ADDED AND  OVERHANG REDUCED WITHIN THE 12"  BOUNDARY REGION ONLY AS FOLLOWS: ** ALLOWABLE ATTACHMENT SPACING  INDICATED ON PLANS TO BE REDUCED BY 50%. ** ALLOWABLE OVERHANG INDICATED ON  PLANS TO BE 1/5TH OF ALLOWABLE  ATTACHMENT SPACING INDICATED ON PLANS. ROOF INFO ATTACHMENT INFORMATION Name Type Height Detail Max Landscape  OC Spacing Max Landscape  Overhang Max Portrait  OC Spacing Max Portrait  Overhang Configuration AR-01 1-Story UR - SPEEDSEAL DECKFOOT TO WOOD DECK - SNR-DC-00450 4'-10" 0'-6" 4'-10" 0'-6"STAGGEREDCOMP SHINGLE SPEEDSEAL DECKFOOT EXISTING STRUCTURE IS ASSUMED TO BE A LIGHT-FRAME WOOD ROOF  AND FREE FROM DAMAGE, DETERIORATION, OR MODIFICATION THAT  WOULD COMPROMISE ITS ORIGINAL DESIGN INTEGRITY. CONTACT  ENGINEER OF RECORD IF FOLLOWING MINIMUM REQUIREMENTS ARE NOT  SATISFIED IN COMPLIANCE WITH THE STATED RACKING DESIGN: SEE SITE PLAN FOR NORTH ARROW D1 - AR-01 - SCALE: 3/16" = 1'-0" AZIM:271° PITCH: 17°   28'-6" 11'-3" 3'-7"3'-6" 1'-7" 6" Signed 10/6/2024 2100 E Wellington Ave11/18/2024 PAGE REV: A1 10/6/2024 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 EFREN LUMBRERAS 2100 E WELLINGTON AVE,  SANTA ANA, CA, 92701 PROJECT NUMBER:   109R-100LUMB SHEET DESIGNER: HIMANSHU VASHIST CUSTOMER RESIDENCE: TEL. (949) 763-0025 APN: 400-153-29 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 MOUNTING DETAIL PV-3.1 SNAPNRACK UR SPEEDSEAL DECKFOOT FOR COMPOSTION ROOF MOUNTING ONTO WOOD DECKING REFER TO SNAPNRACK ENGINEERING CHARTS FOR APPLICABLE RAIL SPANS. "BIN" NUMBER ON CHART SHOULD MATCH "BIN" NUMBER ON THIS DRAWING (X4) #14 FULLY THREADED WOOD SCREWS, S.S. MUST EMBED FULLY INTO WOOD DECK REFER TO SNAPNRACK INSTALLATION MANUAL FOR 5 HARDWARE TORQUE SPECIFICATIONS 16" RAIL CAN MOUNT ON EITHER SIDE OF SPEEDSEAL DECKFOOT. SPEEDSEAL DECKFOOT CAN MOUNT UP, DOWN, OR ACROSS THE SLOPE OF THE ROOF FOR ADDITIONAL LEVELING DETAILS, REFER TO SNAPNRACK DETAIL DRAWING "SNR-DC-00447 ULTRA RAIL, COMPONENT DETAIL, ULTRA RAIL LEVELING SPACER" BIN: 5 SNAPNRACK, SPEEDSEAL DECKFOOT BASE, SEALING SNAPNRACK, UR MOUNT THRU SNAPNRACK, UR MOUNT TAPPED EXPLODED SNAPNRACK, ULTRA RAIL TOP COMP SHINGLE ROOFING, TYP. 3.860 16"-18 X 13 COIL SPRING FOR 3 4" BOLT, SERRATED FLANGE, S.S. 8  BOLT, S.S. (OPTIONAL) 5.200 N/A REVISION: 1 1/13/2021 NEW DETAIL 2 4/5/2021 2PC CLAMP MJA MJA MODULE HEIGHT, MAX: UR-40 = 438" UR-60 = 5" SCREW HEIGHT OFF ROOF: 9 16" 11 11 2" 21 15 8" UR-40 RAIL | UR-60 RAIL DESIGNER: APPROVED BY: M.AFFENTRANGER DRAFTER: M.AFFENTRANGER W.ARBUCKLE SCALE: DATE: DNS 4/5/2021 DRAWING NUMBER: SNR-DC-00450 REV: 2 4" 2" MINIMUM DECK THICKNESS: PLYWOOD:15/32" ATTACHMENT DETAIL SECTION VIEW OSB: 7 16" (4X) #14 FULLY THREADED WOOD SCREW. S.S. MUST EMBED FULLY INTO WOOD DECK INSTALLATION OVERVIEW ROOF DECKING, TYP. Solar Mounting Solutions Sunrun South LLC 595 MARKET STREET, 29TH FLOOR  SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900  FAX (415) 580-6902 THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. COMP SHINGLE ROOFING, TYP. ROOF DECKING, TYP. Signed 10/6/2024 2100 E Wellington Ave11/18/2024 CONDUIT SCHEDULE TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT 1 Inverter Input (2) 10 AWG (PV WIRE)N/A 6 AWG (BARE)Open Air 2 Inverter Input (2) 10 AWG THHN/THWN-2 N/A 8 AWG THHN/THWN-2 3/4 EMT 3 Inverter Output (2) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT 4 Gateway Output (2) 3 AWG THHN/THWN-2 (1) 3 AWG THHN/THWN-2 8 AWG THHN/THWN-2 1 EMT 5 Backup Loads (5) 12 AWG THHN/THWN-2 (5) 12 AWG THHN/THWN-2 8 AWG THHN/THWN-2 1-1/2 EMT (11) 10 AWG THHN/THWN-2 (11) 10 AWG THHN/THWN-2 (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (2) 8 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 EXISTING 100A MAIN BREAKER END FED EXISTING 100A MAIN PANEL 100A BUS M 100A NEW 200A BACKUP GATEWAY 1841000-X1-Y 4 J-BOX LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-400M STRING 1 OF 10 MODULES 4 MODULE LEVEL RAPID SHUTDOWN DEVICES 12 POINT OF INTERCONNECTION: CEC 2022 705.12(B)(3)(3), GATEWAY BREAKER AT OPPOSITE END OF BUSBAR METER NUMBER: 222013-049004 EQUIPMENT CHARACTERISTICS INCLUDED IN SPEC SHEETS NOTE: TOTAL PV BACKFEED = 60A USED FOR INTERCONNECTION CALCULATIONS (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A,2P 120/240VAC 3 NEW\ 225 A GENERATION PANEL AND BACKUP LOAD PANEL (N)- 60A ESS + PV BREAKER 4 FACILITY GROUND BACKUP LOADS 5 3 TESLA POWERWALL 3 1707000-XX-Y TESLA: POWERWALL 3 1707000-XX-Y 11500 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT PAGE REV: B 10/25/2024 EFREN LUMBRERAS 2100 E WELLINGTON AVE, SANTA ANA, CA, 92701 PROJECT NUMBER: 109R-100LUMB SHEET DESIGNER: HIMANSHU VASHIST CUSTOMER RESIDENCE: TEL. (949) 763-0025 APN: 400-153-29 (415) 580-6920 ex3 Template_version_v5_2024.02.28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 PV-4.0 ELECTRICAL #ESTAMP MODULE CHARACTERISTICS LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-400M 400 W OPEN CIRCUIT VOLTAGE 37.05 V MAX POWER VOLTAGE 30.94 V SHORT CIRCUIT CURRENT 14.88 A INSTALLER MUST CHECK THE CONDITION, INSTALLABILITY AND CODE COMPLIANCE OF EXISTING EQUIPMENT. INSTALL THE BACKED UP LOAD CONDUCTORS AND THE GATEWAY BREAKER CONDUCTORS IN TWO SEPARATE CONDUITS. IF THE RELOCATED LOADS EXTEND MORE THAN 6 FEET, AFCI PROTECTION APPLIES PER 2019 CEC 210.12 ANY MULTIWIRE BRANCH CIRCUITS RELOCATED ARE TO BE IDENTIFIED, GROUPED, AND EQUIPPED WITH A 2-POLE OCPD BREAKER PER CEC 210.4(B,D). GENERAL NOTES: COLD WATER GAS BOND B B 2100 E Wellington Ave11/18/2024 PAGE REV: A1 10/6/2024 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 EFREN LUMBRERAS 2100 E WELLINGTON AVE,  SANTA ANA, CA, 92701 PROJECT NUMBER:   109R-100LUMB SHEET DESIGNER: HIMANSHU VASHIST CUSTOMER RESIDENCE: TEL. (949) 763-0025 APN: 400-153-29 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 PV-4.1 ELECTRICAL CALCS Template_version_v5_2024 02 28 ELECTRICAL CALCS SYSTEM INFORMATION 4 KW DC PHOTOVOLTAIC SYSTEM      (10) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-400M, TESLA: POWERWALL 3 1707000-XX-Y ALLOWABLE BACKFEED ALLOWABLE BACKFEED = MAIN PANEL RATING = 100A LOADS IN MAIN PANEL: 30A LOADS + 70A GATEWAY BREAKER = 100A ≤ 100A INTERCONNECTION MEETS CEC 2022 705.12(B)(3)(3) REQUIREMENTS. GATEWAY SYSTEM AC WIRE SIZING MAX AC OUTPUT CURRENT = 70 A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  0.91 X 1 X 95A = 86.45A TERMINAL RATING[110.14(C)] = 4 AWG, 75°C RATED = 85A 85A < 86.45A   TERMINAL RATING GOVERNS CONDUCTOR SIZING 70A < 85A   4 AWG AMPACITY OK THEREFORE 4 AWG IS SUFFICIENT. INVERTER OVERCURRENT PROTECTION (INVERTER MAX CURRENT) X (CONTINUOUS LOAD) =  48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION PER MANUFACTURER DC WIRE SIZING MAX CIRCUIT CURRENT = (MODULE ISC) X (HIGH IRRADIANCE)[690.8(A)(1)] X (CONTINUOUS LOAD)[690.8(B)(1)]=      14.88A X 1.25 = 18.6A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =      0.91 X 1 X 40A = 36.4A TERMINAL RATING[110.14(C)] =      10 AWG, RATED = 35A 35A < 36.4A → TERMINAL RATING GOVERNS CONDUCTOR SIZING.      18.6A < 35A → 10 AWG AMPACITY OK THEREFORE 10 AWG IS SUFFICIENT. AC WIRE SIZING MAX AC OUTPUT CURRENT = (MAX INVERTER OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] = 48 A X 1.25 = 60 A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  0.91 X 1 X 75A = 68.25A TERMINAL RATING[110.14(C)] = 6 AWG,  RATED = 65A 65A < 68.25A →  ADJUSTED CONDUCTOR AMPACITY GOVERNS CONDUCTOR SIZING. 60A < 65A → 6 AWG AMPACITY OK THEREFORE 6 AWG IS SUFFICIENT. SYSTEM CHARACTERISTICS MAX OPEN CIRCUIT VOLTAGE   = {[((TEMP COEF VOC) X (VOC)) / 100] X [LOW TEMP - STC TEMP] + VOC} X (# MODULES / STRING) = {[(-0.26 %/°C X 37.05 V) / 100] X [-2 °C - 25 °C] + 37.05 V} X 10 = 397 V SHORT CIRCUIT CURRENT = 1.25 X (MODULE ISC) X (# STRINGS) 1.25 X 14.88 A X 1 = 18.6A 2100 E Wellington Ave11/18/2024 BACKUP LOADS LOAD BREAKER RATING (AMPS)LABEL DEMAND LOAD(VA) 1 20A-1P GARAGE OUTLETS 1500 VA 2 20A-1P LIVING LIGHTS 1500 VA 3 20A-1P LIVING OUTLETS 1500 VA 4 20A-1P BEDROOM 1 OUTLETS 1500 VA 5 20A-1P BEDROOM 1 LIGHTS 1500 VA 6 20A-1P BEDROOM 2 OUTLETS 1500 VA 7 20A-1P BEDROOM 2 LIGHTS 1500 VA 8 20A-1P KITCHEN OUTLETS 1500 VA 9 20A-1P KITCHEN LIGHTS 1500 VA 10 20A-1P DISHWASHER 1500 VA 11 20A-1P REFRIDGERATOR 1500 VA 12 15A-1P BATH 1 LIGHTS 1500 VA 13 15A-1P BATH 1 OUTLETS 1500 VA 14 15A-1P BATH 2 LIGHTS 1500 VA 15 15A-1P BATH 2 OUTLETS 1500 VA 16 15A-1P GARAGE LIGHTS 1500 VA 17 30A-2P DRYER 5760 VA 18 50A-2P AC 4704 VA BACKUP LOAD CALCS PV-4.2 BACKUP LOAD CALCS #ESTAMP PAGE REV: B 10/25/2024 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 EFREN LUMBRERAS 2100 E WELLINGTON AVE, SANTA ANA, CA, 92701 PROJECT NUMBER: 109R-100LUMB SHEET DESIGNER: HIMANSHU VASHIST CUSTOMER RESIDENCE: TEL. (949) 763-0025 APN: 400-153-29 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 Template_version_v5_2024.02.28 ALL BACKED UP LOADS ABOVE IN THE BACKED UP LOADS PANEL ARE RELOCATED FROM THE MAIN SERVICE PANEL. BACKED UP LOADS CALCULATION: (9600 VA)/ 240V = 19.6 A PER CEC 2022 ARTICLE 690.10 OR NEC 2020 ARTICLE 710.15. THE MAXIMUM CURRENT FOR ALL LARGE APPLIANCES LOADS IS 40A. (1500 VA)/ 120V = 12.5 A PER CEC 2022 ARTICLE 690.10 OR NEC 2020 ARTICLE 710.15. THE MAXIMUM CURRENT FOR ALL SMALL APPLIANCES LOADS IS 12.5A. (MAX LOADS OUTPUT) X (CONTINUOUS LOADS) = 19.6 A X 1.25 = 24.5A; BACKED UP LOADS PANEL BREAKER = 70A 24.5 A < 70A THEREFORE, THE AMPERAGE OF THE BACKED UP LOADS IS LESS THAN THAT OF THE OCPD. AC WIRE SIZING FOR BACKED UP LOADS PANEL: MAX AC OUTPUT CURRENT = (MAX LOADS OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] = 19.6 A X 1.25 = 24.5A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] = 0.91 X 1 X 55A = 50.05A TERMINAL RATING[110.14(C)] = 8 AWG, 75°C RATED = 50A 50A < 50.05A → TERMINAL RATING GOVERNS CONDUCTOR SIZING. 24.5A ≤ 50A → 8 AWG AMPACITY OK THEREFORE 8 AWG IS SUFFICIENT. AC WIRE SIZING FOR BACKED UP LOADS PANEL: MAX AC OUTPUT CURRENT = (MAX LOADS OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] = 12.5 A X 1.25 = 15.625A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] = 0.91 X 1 X 40A = 36.4A TERMINAL RATING[110.14(C)] = 12 AWG, 75°C RATED = 35A 35A < 36.4A → TERMINAL RATING GOVERNS CONDUCTOR SIZING. 15.625A < 35A → 12 AWG AMPACITY OK THEREFORE 12 AWG IS SUFFICIENT. B 2100 E Wellington Ave11/18/2024 PV-4.3 #ESTAMP PANEL SCHEDULE PAGE REV: B 10/25/2024 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 EFREN LUMBRERAS 2100 E WELLINGTON AVE, SANTA ANA, CA, 92701 PROJECT NUMBER: 109R-100LUMB SHEET DESIGNER: HIMANSHU VASHIST CUSTOMER RESIDENCE: TEL. (949) 763-0025 APN: 400-153-29 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 FUTURE 100/100 MAIN PANEL FUTURE 225A GENERATION & BACKUP LOADS PANEL SCHEDULE 50 20 10 0 100 GATEWAY FEEDER BREAKER 60 ESS +PV BREAKER BEDROOM 1 LIGHTS AIR CON 15 15 15 BATHROOM 1 OUTLETS BATHROOM 1 LIGHTS GARAGE LIGHTS 20 20 PANEL SCHEDULE DISHWASHER 20 15 1520 KITCHEN LIGHTS REFRIDGERATOR 30DRYER 20 20 20 20 LIVING OUTLETS KITCHEN OUTLETS LIVING LIGHTS BEDROOM 1 OUTLETS2020 BATHROOM 2 OUTLETS BATHROOM 2 LIGHTS BEDROOM 2 LIGHTS BEDROOM 2 OUTLETS GARAGE OUTLETS B 2100 E Wellington Ave11/18/2024 PAGE REV: A1 10/6/2024 EFREN LUMBRERAS 2100 E WELLINGTON AVE,  SANTA ANA, CA, 92701 PROJECT NUMBER:   109R-100LUMB SHEET DESIGNER: HIMANSHU VASHIST CUSTOMER RESIDENCE: TEL. (949) 763-0025 APN: 400-153-29 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 SIGNAGE PV-5.0 #ESTAMP ENERGY STORAGE SYSTEM  DISCONNECT LABEL LOCATION: ENERGY STORAGE SYSTEM DISCONNECT PER CODE(S): NEC 2020: 706.15(C), CEC 2022: 706.15(C) WARNING! DO NOT RELOCATE THIS  OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS  OCPD (IF APPLICABLE). PER CODE(S): NEC 2020: 705.12(B)(3)(2),  CEC 2022: 705.12(B)(3)(2) NOTES AND SPECIFICATIONS:   SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2022 ARTICLE  110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR  IF REQUESTED BY THE LOCAL AHJ.  SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE  WORDS, COLORS AND SYMBOLS.  LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING  METHOD AND SHALL NOT BE HAND WRITTEN.  LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT  INVOLVED.  SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY  SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.  DO NOT COVER EXISTING MANUFACTURER LABELS. SOLAR PV SYSTEM EQUIPPED  WITH RAPID SHUTDOWN SOLAR ELECTRIC  PV PANELS TURN RAPID SHUTDOWN  SWITCH TO THE "OFF"  POSITION TO SHUT DOWN  PV SYSTEM AND REDUCE  SHOCK HAZARD IN THE  ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE  DISCONNECTING MEANS TO WHICH THE PV SYSTEMS  ARE CONNECTED. PER CODE(S): NEC 2020: 690.56(C), CEC 2022: 690.56(C) 4" 3" ELECTRICAL SHOCK HAZARD WARNING TERMINALS ON LINE AND LOAD  SIDES MAY BE ENERGIZED IN  THE OPEN POSITION LABEL LOCATION: INVERTER(S),  AC/DC DISCONNECT(S),  AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020: 690.13(B), CEC  2022: 690.13(B) ! INVERTER 1 PHOTOVOLTAIC DC DISCONNECT MAXIMUM SYSTEM VOLTAGE:VDC550 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53 WARNING: PHOTOVOLTAIC  POWER SOURCE WARNING: PHOTOVOLTAIC  POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,  AT EACH TURN, ABOVE AND BELOW  PENETRATIONS,  ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2020: 690.31(D)(2), CEC 2022:  690.31(D)(2) PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10 LABEL LOCATION: INSTALLED WITHIN 3' OF RAPID SHUT DOWN  SWITCH PER CODE(S): NEC 2020: 690.56(C)(2),  CEC 2022: 690.56(C)(2), IFC 2018: 1204.5.3 RAPID SHUTDOWN SWITCH  FOR SOLAR PV SYSTEM WARNING! SOURCES: UTILITY GRID,  BATTERY AND PV SOLAR  ELECTRIC SYSTEM THREE POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN  SERVICE PANEL. PER CODE(S): NEC 2020: 705.12(C), CEC  2022: 705.12(C)CAUTION  2100 E WELLINGTON AVE, SANTA ANA, CA, 92701 SOLAR PANELS ON ROOF MULTIPLE SOURCES OF POWER BACKUP GATEWAY GENERATION AND BACKUP LOADS PANEL  SERVICE ENTRANCE AND GATEWAY  FEEDER BREAKER  INVERTER + BATTERY (EXT) MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE:           48 AMPS   240     VAC LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF  INTERCONNECTION. PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54 PV SYSTEM DISCONNECT THIS EQUIPMENT FED BY  MULTIPLE SOURCES. TOTAL  RATING OF ALL OVERCURRENT  DEVICES EXCLUDING MAIN  SUPPLY OVERCURRENT DEVICE  SHALL NOT EXCEED AMPACITY OF  BUSBAR WARNING! LABEL LOCATION: PV LOAD CENTER (IF APPLICABLE) AND  ANY PANEL THAT UTILIZES "THE SUM  OF BREAKERS RULE". PER CODE(S): NEC 2020: 705.12 (B)(3)(3),  CEC 2022: 705.12 (B)(3)(3) 2100 E Wellington Ave11/18/2024 PAGE REV: A1 10/6/2024 EFREN LUMBRERAS 2100 E WELLINGTON AVE,  SANTA ANA, CA, 92701 PROJECT NUMBER:   109R-100LUMB SHEET DESIGNER: HIMANSHU VASHIST CUSTOMER RESIDENCE: TEL. (949) 763-0025 APN: 400-153-29 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 SIGNAGE PV-5.1 #ESTAMP ENERGY STORAGE SYSTEM PREMISES WIRING MAY REMAIN  ENERGIZED AFTER LOSS OF  UTILITY POWER C UTION! LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2022: 706.15(C), NEC 2020: 706.15(C) ENERGY STORAGE SYSTEM DISCONNECT NOMINAL ESS VOLTAGE VAC LABEL LOCATION: MAIN PANEL. 120 240 NEC 2020 - PW3 PER CODE(S): NEC 706.15(C) LABEL LOCATION: BACKED UP LOADS PANEL NO ADDITIONAL  LOADS TO BE  ADDED 2100 E Wellington Ave11/18/2024 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 1 of 8 GFT-OP-11a (22-August-2019) Test Verification of Conformity Verification Number: 104514208CRT-001VOC Applicant Name & Address: Tesla Inc. 3500 Deer Creek Road, Palo Alto, CA 94304 Product Description: Energy Storage System Grid Support Utility Interactive & Standalone Inverter Ratings & Principle Characteristics: See Appendix 2 Models/Type References: 1707000- followed by two numbers; followed by -; followed by one letter. Brand Names: Tesla Relevant Standard(s) / Specification(s): See Appendix 1 Verification Issuing Office Name & Address: Intertek Testing Services NA, Inc. 3933 US Route 11, Cortland, NY 13045 USA Date of Tests: 9/15/2022 to 4/23/2024 Test Report Number(s): 104514208CRT-001, 104514208CRT-001RRF, 104514208CRT-001TRS, 104514208CRT-010, 104514208CRT-012 Additional information in Appendix. Signature Name: Mukund Rana Position: Sr. Staff Engineer Date: 10th May 2024 On the basis of the tests undertaken, the samples of the below product have been found to comply with the requirements of the referenced standards at the time the tests were carried out. This verification is part of the full test report and should be read in conjunction with it. This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 2 of 8 GFT-OP-11a (22-August-2019) Appendix 1: Relevant Standard(s)/Specification(s) Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources [UL 1741:2021 Ed.3] Grid Support Utility Interactive Equipment - Supplement SA to UL 1741:2021 Ed.3 - Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources [UL 1741:2021 Ed.3 (Supplement SA)] Grid Support Utility Interactive Inverters and Converters Based Upon IEEE 1547:2018 & IEEE 1547.1:2020 - Supplement SB to UL 1741:2021 Ed.3 - Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources [UL 1741:2021 Ed.3 (Supplement SB)] Energy Storage Systems and Equipment [ANSI/UL 9540:2020 Ed.2+R:09Apr2021] Photovoltaic (PV) DC Arc-Fault Circuit Protection [UL 1699B:2018 Ed.1+R:18May2021] Software in Programmable Components [UL 1998:2013 Ed.3+R:24Sep2018] Tests For Safety-related Controls Employing Solid-state Devices [UL 991:2004 Ed.3+R:09Jun2010] Batteries for Use in Stationary, Vehicle Auxiliary Power and Light Electric Rail (LER) Applications [ANSI/UL 1973:2018 Ed.2] IEEE 1547:2018 - IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces IEEE 1547a:2020 - IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces Amendment 1: To Provide More Flexibility for Adoption of Abnormal Operating Performance Category III IEEE 1547.1:2020 - IEEE Standard Conformance Test Procedures for Equipment Interconnecting Distributed Energy Resources with Electric Power Systems and Associated Interfaces Source requirements document UL 1741 (SRD) v2.0 – HECO Electric Rule No.21-2020 Generating Facility Interconnections Default New England Bulk System Area Settings Requirement PRC-024-3 Frequency and Voltage Protection Settings for Generating Resources GOVERNMENT OF PUERTO RICO PUBLIC SERVICE REGULATORY BOARD PUERTO RICO ENERGY BUREAU, Generating Facility and Microgrid Interconnection Regulation (“Regulation”), July 2021 Power Conversion Equipment [CSA C22.2#107.1:2016 Ed.4+U1] Interconnection of Distributed Energy Resources and Electricity Supply Systems [CSA C22.3#9:2020 Ed.2] Photovoltaic Rapid Shutdown Systems [CSA C22.2#330:2023 Ed.2] Safety Functions Incorporating Electronic Technology [CSA C22.2#0.8:2019 Ed.4] 2100 E Wellington Ave11/18/2024 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 3 of 8 GFT-OP-11a (22-August-2019) Appendix 2: Ratings & Principle Characteristics: ➢ Ratings: Models 1707000-xx-y Rated AC Output Power (W) 11500, 10000, 7680, 5750 Rated AC Input Power (W) Charging 5000 Max. Cont. Output Power (W) 11500, 10000, 7680, 5750 Max. Continuous Output PV to AC Power Off-Grid (W) 15400 Max. Cont. Input Power (W) Charging 5000 AC Input / Output Voltage (VL-L) 240 AC Output Frequency (Hz) 60 Max. Cont. Output Current (A) 48, 4 1.6, 32, 24 Max. Cont. Input Current (A) Charging 20.83 Apparent Power rating (VA) 11500, 10000, 7680, 5750 Apparent Power rating (VA) Charging 5000 Normal Category A, B Abnormal Category II, III ➢ Communication Protocol: IEEE 2030.5 protocol ➢ PCH board MD5 Firmware checksum: c5773b136a9ef9be9057302a67258482 ➢ TACO board MD5 Firmware checksum: dcq8OiBXbQWYnK9UhCAjvl02/py2MZymmwAQYOn8jSc= ➢ Grid Support Function Parameters: Tesla used the parameters in the Result reporting form “104514208CRT-001RRF” during the testing of the grid support functions according to UL1741 SB. The parameters that have “blank” as their value are not applicable. ➢ UL 1998 and CSA C22.2#0.8 Evaluation: ECU / Board Rev Software version Checksum UL1998, CSA C22.2#0.8 Compliant* Date of evaluation HVP / -E V2 51705DB5 Yes Apr-19-2024 PWS / -3F V2 34204954 Yes Apr-19-2024 PWS / -1F V2 B3C1375B Yes Apr-19-2024 PWS / -D V2 43FEF523 Yes Apr-19-2024 *Note: Below safety functions were evaluated during the UL1998 and UL 991 evaluation. • List of all UL1998 and UL 991 functions are as follow: o Overcharge o Over-discharge o Over Temperature o Over current o Relay weld, Isolation Monitoring Interruption, PV RSD (UL 1741) o AFCI (UL 1699B) This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 4 of 8 GFT-OP-11a (22-August-2019) 2100 E Wellington Ave11/18/2024 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 5 of 8 GFT-OP-11a (22-August-2019) Appendix 3: List of Tested Grid protection / Support Function: Table 3A: Test List -1 Grid protection / Support Function Tested Test Standards Sections and Source Requirement Documents IEEE 1547- 2018 IEEE 1547.1- 2020 UL 1741SB - 2021 CA Rule 21:2020 UL 1741 SRD V2.0 (HECO):2020 OPERATIONAL TEMPERATURE -- 5.3.3.1 SB4.3.5.3 -- Same as 1547- 2018 PROTECTION FROM ELECTROMAGNETIC INTERFERENCE (EMI) TEST 4.11.1 5.8.1 SB4.3.5.8.1 -- Same as 1547- 2018 SURGE WITHSTAND PERFORMANCE TEST 4.11.2 5.8.2 SB4.3.5.8.2 -- Same as 1547- 2018 PARALLELING DEVICE 4.11.3 5.8.3 -- -- Same as 1547- 2018 OVERVOLTAGE TRIP 6.4.1 5.4.2 SB4.3.5.4.2 Electric Rule No. 21 Table Hh.1 Same as 1547- 2018 UNDERVOLTAGE TRIP 6.4.1 5.4.3 SB4.3.5.4.3 Electric Rule No. 21 Table Hh.1 Same as 1547- 2018 OVERFREQUENCY TRIP 6.5.1 5.5.1 & 5.5.2 SB4.3.5.5.1 & SB4.3.5.5.2 Electric Rule No. 21 Table Hh.2 Same as 1547- 2018 UNDERFREQUENCY TRIP 6.5.1 5.5.1 & 5.5.2 SB4.3.5.5.1 & SB4.3.5.5.2 Electric Rule No. 21 Table Hh.2 Same as 1547- 2018 LOW VOLTAGE RIDE-THROUGH 6.4.2.3 & 6.4.2.5 5.4.4 SB4.3.5.4.4 Electric Rule No. 21 Table Hh.1 Same as 1547- 2018 HIGH VOLTAGE RIDE-THROUGH 6.4.2.4 5.4.7 SB4.3.5.4.7 Electric Rule No. 21 Table Hh.1 Same as 1547- 2018 LOW FREQUENCY RIDE-THROUGH 6.5.2.3 5.5.3 SB4.3.5.5.3 Electric Rule No. 21 Table Hh.2 SRD-UL-1741-SA- V2.0 (HECO) Part II B HIGH FREQUENCY RIDE- THROUGH 6.5.2.4 5.5.4 SB4.3.5.5.4 Electric Rule No. 21 Table Hh.2 SRD-UL-1741-SA- V2.0 (HECO) Part II B RATE OF CHANGE OF FREQUENCY 6.5.2.5 5.5.5 -- -- Same as 1547- 2018 ANTI-ISLANDING PROTECTION - WITH GRID SUPPORT FUNCTIONS ENABLED 8.1 5.10.2 SB4.3.5.10.2 Electric Rule No. 21 Hh.1a According to UL 1741 SA-V2.0 (HECO) TEST FOR VOLTAGE PHASE-ANGLE CHANGE RIDE-THOUGH (VARIATION 1) 6.5.2.6 5.5.6.1 SB4.3.5.5.6 -- Same as 1547- 2018 ENTER SERVICE 4.10 5.6 -- -- Same as 1547- 2018 SYNCHRONIZATION CONTROL FUNCTION TEST FOR EQUIPMENT WITH NO SYNCHRONIZING DISABLE CAPABILITY (VARIATION 3) 6.3 5.7.4 -- -- Same as 1547- 2018 LIMITATION OF DC INJECTION FOR INVERTERS 7.1 5.9 -- Electric Rule No. 21 Hh.2h Same as 1547- 2018 OPEN PHASE 6.2.2 5.11 -- -- Same as 1547- 2018 CURRENT DISTORTION 7.3 5.12 -- Electric Rule No. Same as 1547- This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 6 of 8 GFT-OP-11a (22-August-2019) Grid protection / Support Function Tested Test Standards Sections and Source Requirement Documents IEEE 1547- 2018 IEEE 1547.1- 2020 UL 1741SB - 2021 CA Rule 21:2020 UL 1741 SRD V2.0 (HECO):2020 21 Hh.2g 2018 LIMIT ACTIVE POWER 4.6.2 5.13 -- Electric Rule No. 21 Hh.8 Same as 1547- 2018 CONSTANT POWER FACTOR 5.3.2 5.14.3 SB4.3.5.14.3 Electric Rule No. 21 Hh.2i Same as 1547- 2018 VOLTAGE-REACTIVE POWER (VOLT-VAR) MODE FIXED VREF 5.3.3 5.14.4 SB4.3.5.14.4 Electric Rule No. 21 Hh.2J Same as 1547- 2018 VOLTAGE-REACTIVE POWER (VOLT-VAR) MODE (VREF TEST) 5.3.3 5.14.5 SB4.3.5.14.5 -- Same as 1547- 2018 ACTIVE POWER-REACTIVE POWER MODE (WATT-VAR) 5.3.4 5.14.7 SB4.3.5.14.7 -- Same as 1547- 2018 CONSTANT REACTIVE POWER (VAR) MODE 5.3.5 5.14.8 SB4.3.5.14.8 -- Same as 1547- 2018 VOLTAGE-ACTIVE POWER (VOLT- WATT) MODE 5.4 5.14.9 SB4.3.5.14.9 Electric Rule No. 21 Hh.2.m Same as 1547- 2018 TEST FOR FREQUENCY -DROOP (FREQUENCY-POWER OR FREQUENCY-WATT) CAPABILITY — ABOVE NOMINAL FREQUENCY 6.5.2.7 5.15.2 SB4.3.5.15.2 Electric Rule No. 21 Hh.2.l SRD-UL-1741-SA- V2.0 (HECO) Part II C TEST FOR FREQUENCY -DROOP (FREQUENCY-POWER OR FREQUENCY-WATT) CAPABILITY — BELOW NOMINAL FREQUENCY 6.5.2.7 5.15.3 SB4.3.5.15.3 Electric Rule No. 21 Hh.2.l SRD-UL-1741-SA- V2.0 (HECO) Part II C PRIORITIZATION OF DER RESPONSES 4.7 5.16 SB4.3.5.16 -- Same as 1547- 2018 LOAD REJECTION OVERVOLTAGE (LROV) 7.4 5.17.2 SB4.3.5.17.2 -- Same as 1547- 2018 FAULT CURRENT TESTS FOR INVERTERS 6.2.1 5.18.1 -- -- Same as 1547- 2018 PERSISTENCE OF DER PARAMETER SETTINGS -- 5.19 -- -- Same as 1547- 2018 NORMAL RAMP RATE -- -- -- Electric Rule No. 21 Hh.2k -- NAMEPLATE DATA TEST 10.3 6.4 -- -- Same as 1547- 2018 MONITORING INFORMATION TEST 10.5 6.6 SB4.3.6.6 -- Same as 1547- 2018 MANAGEMENT INFORMATION TEST 10.6 6.7 SB4.3.6.7 -- Same as 1547- 2018 2100 E Wellington Ave11/18/2024 2100 E Wellington Ave11/18/2024 Powerwall 3 Power Everything 2024 — Powerwall 3 is a fully integrated solar and battery system, designed to accelerate the transition to sustainable energy. Customers can receive whole home backup, cost savings, and energy independence by producing and consuming their own energy while participating in grid services. Once installed, customers can manage their system using the Tesla App to customize system behavior to meet their energy goals. Powerwall 3 achieves this by supporting up to 20 kW DC of solar and providing 11.5 kW AC of continuous power per unit. It has the ability to start heavy loads up to 185 A LRA, meaning a single unit can support the power needs of most homes. Powerwall 3 is designed for mass production,fast and ef𿿿cient installations,easy system expansion,and simple connection to any electrical service. 22024Powerwall 3 Datasheet Solar Technical Speci￿cations Maximum Solar STC Input 20 kW Withstand Voltage 600 V DC PV DC Input Voltage Range 60 — 550 V DC PV DC MPPT Voltage Range 60 — 480 V DC MPPTs 6 Maximum Current per MPPT (Imp)13 A 5 Maximum Short Circuit Current per MPPT (Isc)15 A 5 Powerwall 3 Technical Specifications 1 Typical solar shifting use case. 2 Values provided for 25°C (77°F), at beginning of life. 3.3 kW charge/discharge power. 3 Tested using CEC weighted ef𿿿ciency methodology. 4 The customer is expected to provide internet connectivity for Powerwall 3;cellular should not be used as the primary mode of connectivity. Cellular connectivity subject to network operator service coverage and signal strength. 5 Where the DC input current exceeds the MPPT rating,a jumper can be used to combine two MPPTs into a single input to intake DC current up to 26 A IMP / 30 A ISC. Battery Technical Speci￿cations Nominal Battery Energy 13.5 kWh AC 2 Maximum Continuous Discharge Power 11.5 kW AC Maximum Continuous Charge Power 5 kW AC Output Power Factor Rating 0 -1 (Grid Code con𿿿gurable) Maximum Continuous Current 48 A Maximum Output Fault Current 10 kA Load Start Capability (1 s)185 A LRA Power Scalability Up to 4 Powerwall 3 units supported System Technical Speci￿cations Model Number 1707000-xx-y Nominal Grid Voltage (Input &Output)120/240 VAC Grid Type Split phase Frequency 60 Hz Overcurrent Protection Device 60 A Solar to Battery to Home/Grid Ef￿ciency 89% 1,2 Solar to Home/Grid Ef￿ciency 97.5% 3 Supported Islanding Devices Gateway 3, Backup Switch, Backup Gateway 2 Connectivity Wi-Fi (2.4 and 5 GHz), Dual-port switched Ethernet, Cellular (LTE/4G 4) Hardware Interface Dry contact relay,Rapid Shutdown (RSD)certi𿿿ed switch and 2-pin connector, RS-485 for meters AC Metering Revenue Grade (+/- 0.5%) Protections Integrated arc fault circuit interrupter (AFCI), Isolation Monitor Interrupter (IMI),PV Rapid Shutdown (RSD)using Tesla Mid-Circuit Interrupters Customer Interface Tesla Mobile App Warranty 10 years 2100 E Wellington Ave11/18/2024 2100 E Wellington Ave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eb 3, 2020 : !!761;!: ;: ;:  , 3 4 3 <) =2::5,3< 2#15()<==  . )( *C . */3.%D //  . )( *  . )( //    . --8  (/. 88  .#1 $+  8  . E8 *  - ( .(.3+  .( -8. 4   ,.4.   / (/.     .3 .A 8 '  -2- ./- .3 44428#14 ..3 2 23' $  3( .$  (  . $ / /"C   ' -8( .  (  . E '*- (/ C % */ C  E -8 ../- .C  .  3( . .  (  .   '  .  (  .< / . ( 3 ( 8 = .'.- . ( (   .'.- . (/( (  */( . / 8 / *(.38  . .    (4  . *   . *:6-.  2100 E Wellington Ave11/18/2024 32024Powerwall 3 Datasheet Mechanical Speci￿cations Dimensions 1099 x 609 x 193 mm (43.25 x 24 x 7.6 in) Weight 130 kg (287 lb) Mounting Options Floor or wall mount Powerwall 3 Technical Specifications Environmental Speci￿cations Operating Temperature –20°C to 50°C (–4°F to 122°F) 6 Operating Humidity (RH)Up to 100%, condensing Storage Temperature –20°C to 30°C (–4°F to 86°F), up to 95% RH, non- condensing, State of Energy (SOE): 25% initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Rating NEMA 3R Ingress Rating IP67 (Battery & Power Electronics) IP45 (Wiring Compartment) Pollution Rating PD3 Operating Noise @ 1 m < 50 db(A) typical <62 db(A)maximum Compliance Information Certi￿cations UL 1642, UL 1699B, UL 1741, UL 1741 SA, UL 1741 SB, UL 1741 PCS, UL 3741, UL 1973, UL 1998, UL 9540, IEEE 1547- 2018, IEEE 1547.1, UN 38.3 Grid Connection United States Emissions FCC Part 15 Class B Environmental RoHS Directive 2011/65/EU Seismic AC156, IEEE 693-2005 (high) Fire Testing Meets the unit level performance criteria of UL 9540A 6 Performance may be de-rated at operating temperatures above 40°C (104°F). 609 mm 193 mm 1099 mm 42024Powerwall 3 Datasheet Electrical Speci￿cations Model MCI-1 MCI-2 Nominal Input DC Current Rating (IMP)13 A 13 A Maximum Input Short Circuit Current (ISC)19 A 17 A Maximum System Voltage (PVHCS)600 V DC 1000 V DC 7 Solar Shutdown Device Technical Specifications Environmental Speci￿cations Operating Temperature -40°C to 50°C (-40°F to 122°F) -45°C to 70°C (-49°F to 158°F) Storage Temperature –30°C to 70°C (–22°F to 158°F) –30°C to 70°C (–22°F to 158°F) Enclosure Rating NEMA 4X /IP65 NEMA 4X /IP65 RSD Module Performance Maximum Number of Devices per String 5 5 Control Power Line Excitation Power Line Excitation Passive State Normally Open Normally Open Maximum Power Consumption 7 W 7 W Warranty 25 years 25 years — The Solar Shutdown Device is a Mid-Circuit Interrupter (MCI)and is part of the PV system rapid shutdown (RSD)function in accordance with Article 690 of the applicable NEC. When paired with Powerwall 3, solar array shutdown is initiated by any loss of AC power. Mechanical Speci￿cations Electrical Connections MC4 Connector MC4 Connector Housing Plastic Plastic Dimensions 125 x 150 x 22 mm (5 x 6 x 1 in) 173 x 45 x 22 mm (6.8 x 1.8 x 1 in) Weight 350 g (0.77 lb) 120 g (0.26 lb) Mounting Options ZEP Home Run Clip M4 Screw (#10) M8 Bolt (5/16") Nail / Wood screw Wire Clip Compliance Information Certi￿cations UL 1741 PVRSE, UL 3741, PVRSA (Photovoltaic Rapid Shutdown Array) RSD Initiation Method External System Shutdown Switch or Powerwall 3 Enable Switch 7 Maximum System Voltage is limited by Powerwall to 600 V DC. UL 3741 PV Hazard Control (and PVRSA)Compatibility See Powerwall 3 Installation Manual 2100 E Wellington Ave11/18/2024 52024Powerwall 3 Datasheet Gateway 3 8 Only Eaton CSR or BWH main breakers are 25 kA rated. Performance Speci￿cations Model Number 1841000-01-y Nominal Grid Voltage 120/240 V AC Grid Con￿guration Split phase Grid Frequency 60 Hz Continuous Current Rating 200 A Maximum Supply Short Circuit Current 22 kA with Square D or Eaton main breaker 25 kA with Eaton main breaker 8 IEC Protective Class Class I Overvoltage Category Category IV Mechanical Speci￿cations Dimensions 660 x 411 x 149 mm (26 x 16 x 6 in) Weight 16.3 kg (36 lb) Mounting options Wall mount Environmental Speci￿cations Operating Temperature –20°C to 50°C (–4°F to 122°F) Operating Humidity (RH)Up to 100%, condensing Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R Compliance Information Certi￿cations UL 67, UL 869A, UL 916, UL 1741 PCS, CSA 22.2 107.1, CSA 22.2 29 Emissions FCC Part 15, ICES 003 — Tesla Gateway 3 controls connection to the grid in a Powerwall system, automatically detecting outages and providing seamless transition to backup power. It provides energy monitoring that is used by Powerwall for solar self-consumption, time-based control, and backup operation. 411 mm 660 mm 149 mm AC Meter Revenue accurate (+/- 0.5%) Communication CAN User Interface Tesla App Backup Transition Automatic disconnect for seamless backup Overcurrent Protection Device 100–200 A Service entrance rated Eaton CSR, BWH, or BW, or Square D QOM breakers Internal Panelboard 200 A 8-space/16 circuit breakers Eaton BR, Siemens QP, or Square D HOM breakers rated to 10–125A Warranty 10 years 62024Powerwall 3 Datasheet Backup Switch 9 Breaker maximum supply short circuit current rating must be equal to or greater than the available fault current. Performance Speci￿cations Model Number 1624171-xx-y Continuous Load Rating 200 A, 120/240 V split phase Maximum Supply Short Circuit Current 22 kA with breaker 9 Communication CAN AC Meter Revenue accurate (+/- 0.5%) Expected Service Life 21 years Warranty 10 years Mechanical Speci￿cations Dimensions 176 x 205 x 74 mm (6.9 x 8.1 x 2.9 in) Weight 2.8 lb Meter and Socket Compatibility ANSI Type 2S, ringless or ring type External Service Interface Contactor manual override 10 Reset button Conduit Compatibility 1/2-inch NPT Environmental Speci￿cations Operating Temperature –40°C to 50°C (–40°F to 122°F) Storage Temperature –40°C to 85°C (–40°F to 185°F) Enclosure Rating NEMA 3R Pollution Rating PD3 Compliance Information Safety Standards USA: UL 414, UL 414 SB, UL 2735, UL 916, CA Prop 65 Emissions FCC, ICES 10 Manually overrides the contactor position during a service event. — The Tesla Backup Switch controls connection to the grid in a Powerwall system, and can be easily installed behind the utility meter or in a standalone meter panel downstream of the utility meter. The Backup Switch automatically detects grid outages, providing a seamless transition to backup power. It communicates directly with Powerwall, allowing home energy usage monitoring from any mobile device with the Tesla app. 204.86 74 176 mm 205 mm 74 mm 2100 E Wellington Ave11/18/2024 72024Powerwall 3 Datasheet Backup Gateway 2 Performance Speci￿cations Model Number 1232100-xx-y AC Voltage (Nominal)120/240 V Feed-in Type Split phase Grid Frequency 60 Hz Current Rating 200 A Maximum Supply Short Circuit Current 10 kA 11 Overcurrent Protection Device 100 - 200 A, Service entrance rated 9 Overvoltage Category Category IV Internal Primary AC Meter Revenue accurate (+/- 0.2%) Internal Auxiliary AC Meter Revenue accurate (+/- 2%) Primary Connectivity Ethernet, Wi-Fi Secondary Connectivity Cellular (3G, LTE/4G) 12 Mechanical Speci￿cations Dimensions 660 x 411 x 149 mm (26 x 16 x 6 in) Weight 20.4 kg (45 lb) Mounting options Wall mount, Semi-Bush mount Environmental Speci￿cations Operating Temperature –20°C to 50°C (–4°F to 122°F) Operating Humidity (RH)Up to 100%, condensing Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R Compliance Information Certi￿cations UL 67, UL 869A, UL 916, UL 1741 PCS, CSA 22.2 0.19, CSA 22.2 205 Emissions FCC Part 15, ICES 003 411 mm 660 mm 149 mm 11 When protected by Class J fuses, Backup Gateway 2 is suitable for use in circuits capable of delivering not more than 22kA symmetrical amperes. 12 Cellular connectivity subject to network operator service coverage and signal strength. — Backup Gateway 2 controls connection to the grid when paired with Powerwall 3, automatically detecting outages and providing seamless transition to backup power. Backup Gateway 2 also provides energy metering for solar self-consumption, time-based control, and backup operation. In this system con𿿿guration,Powerwall 3 acts as the Site Controller,with the Backup Gateway 2 Site Controller disabled. User Interface Tesla App Operating Modes Support for solar self- consumption, time-based control, and backup Backup Transition Automatic disconnect for seamless backup Modularity Supports up to 10 AC- coupled Powerwalls Optional Internal Panelboard 200 A 6-space / 12 circuit breakers Siemens QP or Square D HOM breakers rated 10 - 80A or Eaton BR breakers rated 10 - 125A Warranty 10 years 82024Powerwall 3 Datasheet Powerwall 3 Example System Configurations Powerwall 3 with Backup Switch Whole Home Backup Powerwall 3 with Gateway 3 Whole Home Backup Powerwall 3 with Backup Gateway 2 Partial Home Backup 2100 E Wellington Ave11/18/2024 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 7 of 8 GFT-OP-11a (22-August-2019) Table 3B: Test List -2 Test Description CSA C22.2#107.1:2016 Ed. 4 CSA C22.3#9:2020 Ed 2 Screw Tightening Torque Test 3.6.3 -- Impedance Test 105.1/10.5.2 -- Continuity Test 4.1 -- Output Power Factor 4.2 -- Voltage Harmonics for stand alone 15.3.2.1 -- Frequency 10.5.4 -- Stand-alone inverter dc output short-circuits current contribution 10.5.5 -- Normal ramp rate -- 7.2.3.4.2 / 8.3.12.2.3 Flicker -- 7.2.2 / 8.3.13 Test for constant reactive power (var) mode 7.2.3.3.3 / 8.3.12.2.2 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 8 of 8 GFT-OP-11a (22-August-2019) Appendix 4: Revision Summary Date / Project Engineer Comments 15-Feb-2023 Dipesh Patel Original issue date 8-Mar-2023 / G104200718 Dipesh Patel Added UL 1699B, UL 1998 and UL 991 standards 24-Mar-2023/ G104200718 Dipesh Patel Added UL 1973 standard. Added normal and abnormal category in ratings table. 18-Apr-2023 / G104200718 Dipesh Patel Added additional factory settable nameplate ratings rated output active power (W): 9600, 7680, 5750; Max. Continuous output power (W): 9600, 7680, 5750; Max. Cont. Output Current (A): 40, 32, 24; Apparent Power rating (VA): 9600, 7680, 5750 Added Puerto Rico Interconnection regulation as it refers to UL 1741 and IEEE 1547-2018. 1-May-2024 / G104514208 Mukund Rana A) Added standards. Power Conversion Equipment [CSA C22.2#107.1:2016 Ed.4+U1] Interconnection of Distributed Energy Resources and Electricity Supply Systems [CSA C22.3#9:2020 Ed.2] Photovoltaic Rapid Shutdown Systems [CSA C22.2#330:2023 Ed.2] Interconnection of Distributed Energy Resources and Electricity Supply Systems [CSA C22.3#9:2020 Ed.2] B) Update CSA C22.2#0.8 standard C) added Table 3B: Test List -2 2100 E Wellington Ave11/18/2024 Service Voltage 240 Section 220.83 Existing Dwelling Unit Part #1 - Section 220.83 (B)(1) General Lighting/Receptacles @ 3 VA per sq ft: Amps Box A (VA) 31.25 7500 Part #2 - Section 220.83(B)(2), (3)a, b, c, d - Appliances and Dedicated Circuits: Size in VA Size in VA 1500 1500 1500 1000 600 1000 1600 Amps Box B (VA) 36.25 8700 Total VA from Parts #1 and #2 combined:Box A + Box B =16200 Total VA 16200 First 8000 VA @ 100%8000 Remaining VA @ 40% Remaining VA =8200 8200 x 40% =3280 VA Adding First 8000 VA, if possible 8000 VA Total VA for Gen. Lights/Recep, Appliances & Dedicated circuits:11280 VA Total AMP for Gen. Lights/Recep, Appliances & Dedicated circuits:47.00 Amps Part #3 - Section 220.83(B) Heating and A/C loads: *Combine the larger loads of either the Heating or the A/C loads togther 100% of all the Heating or A/C loads in VA:4,704 VA 100% of all the Heating or A/C loads in Amps:19.60 A VA Volts Amps Parts #1 & #2 11280 240 47.00 Part #3 4,704 240 19.60 Total VA for all Parts:15,984 Totals Service/Feeder Load 66.60 Dedicated circuit Dedicated circuit Article 220 - Dedicated Backup Panel Calculation Job Code 2100 E Wellington Ave Santa Ana CA USA 92701 109R-100LUMB Building Square Footage VA (watts)Amps House 2500.00 7500 31.25 Total for Part #1: Laundry Appliance Circuit - 1 Appliance Circuit - 2 Dishwasher Disposal Refrigerator Microwave Totals for Part #2: Totals from all Parts 2100 E Wellington Ave11/18/2024 Section 220.83 Existing Dwelling Unit Part #1 - Section 220.83 (B)(1) General Lighting/Receptacles @ 3 VA per sq ft: Amps Box A (VA) 31.25 7500 Part #2 - Section 220.83 (B)(2),(3)a, b, c, d - Appliances and Dedicated Circuits: Size in VA Size in VA 1500 N/A 3000 N/A 1000 N/A 600 N/A 1000 N/A 1600 N/A 5760 N/A N/A N/A N/A N/A N/A Amps Box B (VA) N/A 60.25 14460 Total VA from Parts #1 and #2 combined:Box A + Box B =21960 Total VA 21960 First 8,000 VA @ 100%8000 Remaining VA @ 40% Remaining VA =13960 13960 x 40% =5584 VA Adding First 8000 VA 8000 VA Total VA for Gen. Lights/Recep, Appliances & Dedicated circuits:13584 VA Total AMP for Gen. Lights/Recep, Appliances & Dedicated circuits:56.60 Amps Part #3 - Section 220.83 (B) Heating and A/C loads: *Combine the larger loads of either the Heating or the A/C loads togther 100% of all the Heating or A/C loads in VA:4,704 VA 100% of all the Heating or A/C loads in Amps:19.60 A VA Volts Amps Parts #1 & #2 13584 240 56.60 Part #3 4,704 240 19.60 Total VA for all Parts:18,288 Totals Service/Feeder Load 76.20 #ESTAMP Laundry Appliance Circuit(s) Dishwasher(s) Disposal(s) Dedicated circuit House Square Footage 2500 Article 220 - Service/Feeder calculation for (address): 2100 E Wellington Ave Santa Ana CA USA 92701 Building VA (watts) 7500 Amps 31.25 Job Code 109R-100LUMB Totals from all Parts Dedicated circuit Total for Part #1: Water Heater Refrigerator(s) Microwave(s) Totals for Part #2:Pool Equipment Dryer Range Oven Cooktop 2100 E Wellington Ave11/18/2024 Bus Rating:100 Main Rating:100 0%26% Itemized House and 240V Loads for Panel: (VA) 5760 Not Fed by other panels Feeds: Panel 2 61.35 14.85 76.20 Bus Rating:225 Main Rating:70 100%74% Itemized House and 240V Loads for Panel: (VA) 1500 1500 1500 1000 600 1000 1600 4704 Fed by: Panel 1 61.35 61.35Total Load Calc: Disposal Load Calc: (This Panel) Dryer Load Calc: (This Panel) Total Load Calc: Panel 2 of 2 Refrigerator Microwave A/C Unit - 240V Laundry Appliance Circuit - 1 Appliance Circuit - 2 Dishwasher Panel % of Sq.Ft:Panel % of 100% VA: Panel 1 of 2 Panel % of Sq.Ft:Panel % of 100% VA: 2100 E Wellington Ave11/18/2024 City of Santa Ana, SIGNATURE:___________________ DATE:__________ 717 17th Street, Ste. 200 | Denver, CO 80202  I, Efren Lumbreras, grant authorization to SUNRUN SOLAR to install Rooftop Mounted Solar on my residence located at 2100 e wellington ave , SANTA ANA, CA, 92701. Docusign Envelope ID: F5943A89-403A-416A-96D8-EDBA17FA2AE7 10/9/2024 2100 E Wellington Ave11/18/2024 Certificate Of Completion Envelope Id: F5943A89403A416A96D8EDBA17FA2AE7 Status: Completed Subject: Complete asap for Sunrun project----Efren-- 109R-100LUMB----Solar Authorization Letter.pdf Source Envelope: Document Pages: 1 Signatures: 1 Envelope Originator: Certificate Pages: 6 Initials: 0 Daniel Munoz AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) 225 Bush Street, Suite 1400 San Francisco, CA 94104 daniel.munoz@sunrun.com IP Address: 73.111.240.71 Record Tracking Status: Original 10/9/2024 10:45:10 AM Holder: Daniel Munoz daniel.munoz@sunrun.com Location: DocuSign Signer Events Signature Timestamp Efren Lumbreras elumber80@yahoo.com Mr Security Level: Email, Account Authentication (None)Signature Adoption: Pre-selected Style Using IP Address: 76.33.93.147 Signed using mobile Sent: 10/9/2024 10:49:39 AM Viewed: 10/9/2024 11:34:08 AM Signed: 10/9/2024 11:34:41 AM Electronic Record and Signature Disclosure: Accepted: 10/9/2024 11:34:08 AM ID: dd79485e-b117-4260-b7c5-cb7f476573a2 In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Ian Bunker ian.bunker@sunrun.com Mr.Ian Bunker Security Level: Email, Account Authentication (None) Sent: 10/9/2024 10:49:39 AM Viewed: 10/9/2024 11:11:06 AM Electronic Record and Signature Disclosure: Accepted: 10/8/2024 10:48:46 AM ID: ed05bd1f-39f1-4346-a3f6-80438faef792 Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 10/9/2024 10:49:39 AM Certified Delivered Security Checked 10/9/2024 11:34:08 AM Signing Complete Security Checked 10/9/2024 11:34:41 AM Completed Security Checked 10/9/2024 11:34:41 AM 2100 E Wellington Ave11/18/2024 Payment Events Status Timestamps Electronic Record and Signature Disclosure 2100 E Wellington Ave11/18/2024 CONSUMER DISCLOSURE From time to time, Sunrun Inc. (we, us or Company) may be required by law to provide to you certain written notices or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures electronically through the DocuSign, Inc. (DocuSign) electronic signing system. PLEASE READ THE INFORMATION BELOW CAREFULLY AND THOROUGHLY, AND IF YOU CAN ACCESS THIS INFORMATION ELECTRONICALLY TO YOUR SATISFACTION AND AGREE TO THESE TERMS AND CONDITIONS, PLEASE CONFIRM YOUR AGREEMENT BY CLICKING THE 'I AGREE' BUTTON AT THE BOTTOM OF THIS DOCUMENT. Getting paper copies At any time, you may request from us a paper copy of any record provided or made available electronically to you by us. You will have the ability to download and print documents we send to you through the DocuSign system during and immediately after signing session and, if you elect to create a DocuSign signer account, you may access them for thirty (30) days after such documents are first sent to you. After such time, if you wish for us to send you paper copies of any such documents from our office to you, please request delivery of such paper copies from us by following the procedure described below. Withdrawing your consent If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and disclosures electronically is described below. Consequences of changing your mind If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can complete certain steps in transactions with you and delivering services to you because we will need first to send the required notices or disclosures to you in paper format, and then wait until we receive back from you your acknowledgment of your receipt of such paper notices or disclosures. To indicate to us that you are changing your mind, you must withdraw your consent using the DocuSign ‘Withdraw Consent’ form on the signing page of a DocuSign envelope instead of signing it. This will indicate to us that you have withdrawn your consent to receive required notices and disclosures electronically from us and you will no longer be able to use the DocuSign system to receive required notices and consents electronically from us or to sign electronically documents from us. All notices and disclosures will be sent to you electronically Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you through the DocuSign system all required notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the disclosures and notices electronically or in paper format through the paper mail delivery system. If you do not agree with this process, please let us know as described below. Please also see the paragraph immediately above that describes the consequences of your electing not to receive delivery of the notices and disclosures electronically from us. Electronic Record and Signature Disclosure created on: 8/7/2013 10:17:58 AM Parties agreed to: Efren Lumbreras, Ian Bunker 2100 E Wellington Ave11/18/2024 How to contact Sunrun Inc.: You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as follows: To contact us by email send messages to: customercare@sunrun.com You may also contact us in writing at 45 Fremont Street, 32nd Floor, San Francisco, CA 94105 or by phone at 1-855-478-6786. To advise Sunrun Inc. of your new e-mail address To let us know of a change in your e-mail address where we should send notices and disclosures electronically to you, you must send an email message to us at customercare@sunrun.com and in the body of such request you must state: your previous e-mail address, your new e-mail address. We do not require any other information from you to change your email address. In addition, you must notify DocuSign, Inc. at 1-866-219-4318 to arrange for your new email address to be reflected in your DocuSign account by following the process for changing e-mail in the DocuSign system. To request paper copies from Sunrun Inc. To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically, you must contact us by (a) sending us an e-mail to customercare@sunrun.com, (b) writing to us at Sunrun Inc, 45 Fremont Street, 32nd Floor, San Francisco, CA 94105, or (c) calling us at 1-855-478-6786, and in connection with your request you must state your e-mail address, full name, US Postal address, and telephone number. To withdraw your consent with Sunrun Inc. To inform us that you no longer want to receive future notices and disclosures in electronic format you may: i. decline to sign a document from within your DocuSign session, and on the subsequent page, select the check-box indicating you wish to withdraw your consent, or you may; ii. contact us by (a) sending us an email to customercare@sunrun.com, (b) writing to us at Sunrun Inc., 45 Fremont Street, 32nd Floor, San Francisco, CA 94105, or (c) calling us at 1-855-478-6786, and in connection with your request you must state your e-mail, full name, US Postal Address, and telephone number. We do not need any other information from you to withdraw consent.. The consequences of your withdrawing consent for online documents will be that transactions may take a longer time to process.. Required hardware and software Operating Systems: Windows® 2000, Windows® XP, Windows Vista®; Mac OS® X 2100 E Wellington Ave11/18/2024 Browsers: Final release versions of Internet Explorer® 6.0 or above (Windows only); Mozilla Firefox 2.0 or above (Windows and Mac); Safari™ 3.0 or above (Mac only) PDF Reader: Acrobat® or similar software may be required to view and print PDF files Screen Resolution: 800 x 600 minimum Enabled Security Settings: Allow per session cookies ** These minimum requirements are subject to change. If these requirements change, you will be asked to re-accept the disclosure. Pre-release (e.g. beta) versions of operating systems and browsers are not supported. Notices Any notice or other communication to be made hereunder, even if otherwise required to be in writing under other provisions of this Consent or any other documents or agreements that have been provided to you in connection with this Consent, may alternatively be made in an electronic record transmitted electronically to the electronic addresses provided by you. Any notice or other communication made in electronic form will have the same legal effect and enforceability as if made in non-electronic form. Acknowledging your access and consent to receive materials electronically To confirm to us that you can access this information electronically, which will be similar to other electronic notices and disclosures that we will provide to you, please verify that you were able to read this electronic disclosure and that you also were able to print on paper or electronically save this page for your future reference and access or that you were able to e-mail this disclosure and consent to an address where you will be able to print on paper or save it for your future reference and access. Further, if you consent to receiving notices and disclosures exclusively in electronic format on the terms and conditions described above, please let us know by clicking the ‘I agree’ button below. By checking the ‘I agree’ box, I confirm that:  I can access and read and have accessed, read and understood the terms of this ELECTRONIC CONSENT TO ELECTRONIC RECEIPT OF ELECTRONIC CONSUMER DISCLOSURES document; and  I can print on paper the disclosure or save or send the disclosure to a place where I can print it, for future reference and access; and  Until or unless I notify Sunrun Inc. as described above, I consent to receive from exclusively through electronic means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to me by Sunrun Inc. during the course of my relationship with you. Entire Agreement Provision This agreement and the consumer disclosure statement executed by the customer in conjunction with and simultaneously with its review and acceptance of the terms set forth herein constitute 2100 E Wellington Ave11/18/2024 the entire agreement between the parties with respect to the subject matter hereof and supersede any prior understandings, agreements, or representations by or between the parties, written or oral, to the extent they relate in any way to the subject matter hereof. 2100 E Wellington Ave11/18/2024 2100 E Wellington Ave11/18/2024 10/6/2024 RE: Structural Certification for Installation of Residential Solar EFREN LUMBRERAS:2100 E WELLINGTON AVE, SANTA ANA, CA, 92701 Attn: To Whom It May Concern Design Criteria Code 2022 California Building Code (ASCE 7-16) Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 96 mph PV Dead Load DPV 3 psf Exposure B Roof Live Load Lr 20 psf Ground Snow S 0 psf If you have any questions on the above, please do not hesitate to call. Sincerely, Eugene Munyanziza, P.E. EV Engineering, LLC projects@evengineersnet.com Signed 10/6/2024 http://www.evengineersnet.com Exp: 06/30/2026 Structural evalution were done in accordance with applicable building codes and considering design criteria below: This Letter is for a structural evaluation of the existing structure at the address above. The purpose of our review was to determine the adequacy of the existing structure to support the proposed installation of solar panels as well as the attachment of solar panel to the existing framing. After review, we concluded that the existing structure is adequate to support the proposed solar panel installation. Gravity load increase did not exceed 5% and therefore, this install meets the prescriptive compliance requirements of the applicable IEBC. projects@evengineersnet.com http://www.evengineersnet.com 2100 E Wellington Ave11/18/2024 Wind (Uplift Check) DCR check= 0.76 CONNECTION PASS Vertical Load Resisting System Design Gravity Load Check Roof Dead Load Roof Dead Load 10.0 psf PV Dead Load 3.0 psf Roof Live Load 20 psf PV Roof Live Load 0 psf Snow Load 0 psf IEBC Check Existing With PV Roof Dead Load (D) 10.0 13.0 psf Roof Live Load (Lr) 19.1 0.0 psf Roof Snow Load (S) 0.0 0.0 psf Cs= 1 0.88 Existing With PV (D + Lr) = 23.3 14.4 psf (D + S) = 8.7 11.3 psf Maximum Gravity Load 23.3 14.4 psf Load Increase (%)-38.0% OK IBC Provision 2018 Siesmic Loads Check Roof Dead Load 10 psf % or Roof with Pv 8.4% Dpv and Racking 3 psf Average Total Dead Load 10.3 psf Increase in Dead Load 1.3%OK Limits of Scope of Work and Liability *The requirements of Section 806.2 of the 2018 IEBC are met and the structure is permitted to remain unaltered. The Existing structure is assumed to have been designed and constructed following appropriate codes and to have appropriate permits. The analysis was according to applicable building codes, professional engineering and design experience, opinions and judgments. This evalution produced for this structure's assessment is only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures. Prior to commencement of work, the contractor shall verify the framing sizes, spacings, and spans. Contractor shall also verify that there is framing damage or deficiencies. If observed, the EOR must be notified before install. The increase in seismic Dead weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. projects@evengineersnet.com http://www.evengineersnet.com 2100 E Wellington Ave11/18/2024 Rev: 8/29/19 SOL-01 CBC 2016 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org RESIDENTIAL PHOTOVOLTAIC CHECKLIST caitlyn hernandez 385-400-5019 oc_permits@sunrun.com 2100 E Wellington Ave11/18/2024 PAGE REV: F 6/2/2025 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 EFREN LUMBRERAS 2100 E WELLINGTON AVE, SANTA ANA, CA, 92701 PROJECT NUMBER: 109R-100LUMB SHEET DESIGNER: KEVIN SIN CUSTOMER RESIDENCE: TEL. (949) 763-0025 APN: 400-153-29 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 PV-2.1 INTERIOR GARAGE WALL ACD ESS ELEVATION VIEW - SCALE = NTS ESS ELEVATION VIEW ESS ELEVATION VIEW PW3 ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS IN ACCORDANCE WITH R328.4. ESS UNITS SHALL BE SEPARATED FROM EACH OTHER BY NOT LESS THAN 3 FEET EXCEPT WHERE SMALLER SEPARATION DISTANCES ARE DOCUMENTED TO BE ADEQUATE BASED ON LARGE/SCALE FIRE TESTING. NO DWELLING DOORS OR WINDOWS ARE IN NEARBY HEAT SENSOR 15' 3'MIN A HEAT DETECTOR, LISTED AND INTERCONNECTED TO THE SMOKE ALARMS, SHALL BE INSTALLED IN LOCATIONS WITHIN DWELLING UNITS AND ATTACHED GARAGES WHERE SMOKE ALARMS CANNOT BE INSTALLED BASED ON THEIR LISTING. F Signed: 06/03/2025 Revision to 20184282 issued on 11/18/2024 Rev 1 # 20185569 APPROVALS: ELECT - M. Smith PAGE REV: F 6/2/2025 EFREN LUMBRERAS 2100 E WELLINGTON AVE, SANTA ANA, CA, 92701 PROJECT NUMBER: 109R-100LUMB SHEET DESIGNER: KEVIN SIN CUSTOMER RESIDENCE: TEL. (949) 763-0025 APN: 400-153-29 (415) 580-6920 ex3 Template_version_v5_2024.02.28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 PL PL PL PL PLPL PL PL PL PL PL PL SITE PLAN PV-2.0 #SSTAMPSP #ESTAMPSP NOTES: ·RESIDENCE DOES NOT CONTAIN ACTIVE FIRE SPRINKLERS. ARRAY DETAILS: ·TOTAL ROOF SURFACE AREA: 2500 SQFT. ·TOTAL PV ARRAY AREA: 210.2 SQ FT. ·PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE AREA) * 100 = 8.4% ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS IN ACCORDANCE WITH R328.4. ESS UNITS SHALL BE SEPARATED FROM EACH OTHER BY NOT LESS THAN 3 FEET EXCEPT WHERE SMALLER SEPARATION DISTANCES ARE DOCUMENTED TO BE ADEQUATE BASED ON LARGE/SCALE FIRE TESTING. SITE PLAN - SCALE = 1/16" = 1'-0" (E) RESIDENCE (N) ARRAY AR-01 FIRE SETBACKS (18" TYP)ROOF PATHWAYS (3' TYP) SE MP E WELLINGTON AVE ROOF PATHWAYS (3' TYP) MD AC INV (E) FENCE (E) CHIMNEY (E) GATE(TYP.) A AA A A A A A AA GENERATION PANEL RAIL STANDOFFS & FOOTINGS SOLAR MODULES SOLAREDGE METER AC DISCONNECT(S) PM SE MP MAIN PANEL SERVICE ENTRANCE SCALE: NTS NOTE: NOT ALL ITEMS IN LEGEND WILL APPEAR IN SITE PLAN LEGEND SM INV INVERTER(S) AC DC DISCONNECT(S)DEDICATED PV METER DC SUB-PANELSP LC PV LOAD CENTER SEM BACKUP LOADS PANEL BACKUP INTERFACE MICROGRID INTERCONNECT DEVICE AM ENERGY STORAGE SYSTEM METER ADAPTER MD BP MA BIACREL METER ELECTRIC VEHICLE SUPPLY EQUPMENTEV CB IQ COMBINER BOX 1 COMMUNICATION WIRES GROUNDING ELECTRODE BACKUP GATEWAY GP BG POWERWALL ENERGY STORAGE SYSTEM (ESS) INTERIOR EQUIPMENT SHOWN AS DASHED EXTERNAL RAPID SHUTDOWN SWITCHRSD ARRAY PITCH PV AREA (SQFT) AR-01 18° 210.2 TRUE AZIM MAG AZIM 259°271° NOTE: ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE INSTALLED PER NEC 690.12 ESS INTERIOR INSTALLATION WILL COMPLY WITH SMOKE AND HEAT MONITORING REQUIREMENTS FOR 2022 CFC 1207.11.6 ESS INTERIOR INSTALLATION LOCATION WILL COMPLY WITH IMPACT PROTECTION REQUIREMENTS FOR 2022 CFC 1207.11.7.3 RSD F AC Signed: 06/03/2025 PAGE REV: F 6/2/2025 EFREN LUMBRERAS 2100 E WELLINGTON AVE, SANTA ANA, CA, 92701 PROJECT NUMBER: 109R-100LUMB SHEET DESIGNER: KEVIN SIN CUSTOMER RESIDENCE: TEL. (949) 763-0025 APN: 400-153-29 (415) 580-6920 ex3 Template_version_v5_2024.02.28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 NEW 200A MAIN BREAKER END FED NEW 200A MAIN PANEL 225A BUS 60A J-BOX LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-400M STRING 1 OF 10 MODULES 4 MODULE LEVEL RAPID SHUTDOWN DEVICES 12   POINT OF INTERCONNECTION: 705.12(B)(3)(2), GATEWAY BREAKER AT OPPOSITE END OF BUSBAR   METER NUMBER: 222013-049004   EQUIPMENT CHARACTERISTICS INCLUDED IN SPEC SHEETS   NOTE: TOTAL PV BACKFEED = 60A USED FOR INTERCONNECTION CALCULATIONS(N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A,2P 120/240VAC 3 FACILITY GROUND 3 TESLA POWERWALL 3 1707000-XX-Y TESLA: POWERWALL 3 1707000-XX-Y 11500 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT M TESLA BACKUP SWITCH (N) IMO PE69-3020, DISCONNECT SWITCH, 3P, 16A RSD (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A,2P 120/240VAC 3 CONDUIT SCHEDULE TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT 1 Inverter Input (2) 10 AWG (PV WIRE)N/A 6 AWG (BARE) Open Air 2 Inverter Input (2) 10 AWG THHN/THWN-2 N/A 8 AWG THHN/THWN-2 3/4 EMT 3 Inverter Output (2) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT PV-4.0 ELECTRICAL #ESTAMP MODULE CHARACTERISTICS LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-400M 400 W OPEN CIRCUIT VOLTAGE 37.05 V MAX POWER VOLTAGE 30.94 V SHORT CIRCUIT CURRENT 14.88 A INSTALLER MUST CHECK THE CONDITION, INSTALLABILITY AND CODE COMPLIANCE OF EXISTING EQUIPMENT. INSTALL THE BACKED UP LOAD CONDUCTORS AND THE GATEWAY BREAKER CONDUCTORS IN TWO SEPARATE CONDUITS. IF THE RELOCATED LOADS EXTEND MORE THAN 6 FEET, AFCI PROTECTION APPLIES PER 2019 CEC 210.12 ANY MULTIWIRE BRANCH CIRCUITS RELOCATED ARE TO BE IDENTIFIED, GROUPED, AND EQUIPPED WITH A 2-POLE OCPD BREAKER PER CEC 210.4(B,D) A HEAT DETECTOR, LISTED AND INTERCONNECTED TO THE SMOKE ALARMS, SHALL BE INSTALLED IN LOCATIONS WITHIN DWELLING UNITS AND ATTACHED GARAGES WHERE SMOKE ALARMS CANNOT BE INSTALLED BASED ON THEIR LISTING.. GENERAL NOTES: • CITY REQUIRES TWO SOURCES OF GROUND - UFER, TWO GROUNDS RODS OR COLD WATER GAS BOND F F PAGE REV: F 6/2/2025 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 EFREN LUMBRERAS 2100 E WELLINGTON AVE, SANTA ANA, CA, 92701 PROJECT NUMBER: 109R-100LUMB SHEET DESIGNER: KEVIN SIN CUSTOMER RESIDENCE: TEL. (949) 763-0025 APN: 400-153-29 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 PV-4.1 ELECTRICAL CALCS Template_version_v5_2024.02.28 ELECTRICAL CALCS SYSTEM INFORMATION 4 KW DC PHOTOVOLTAIC SYSTEM (10) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-400M, TESLA: POWERWALL 3 1707000-XX-Y ALLOWABLE BACKFEED ALLOWABLE BACKFEED = (MAIN PANEL RATING) X 1.2 - (MAIN BREAKER RATING) = 225A X 1.2 - 200A = 70A 60A ≤ 70A → INTERCONNECTION MEETS 705.12(B)(3)(2) REQUIREMENTS. DC WIRE SIZING MAX CIRCUIT CURRENT = (MODULE ISC) X (HIGH IRRADIANCE)[690.8(A)(1)] X (CONTINUOUS LOAD)[690.8(B)(1)]= 14.88A X 1.25 X 1.25= 23.25A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] = 0.91 X 1 X 40A = 36.4A TERMINAL RATING[110.14(C)] = 10 AWG, RATED = 35A 35A < 36.4A → TERMINAL RATING GOVERNS CONDUCTOR SIZING. 23.25A < 35A → 10 AWG AMPACITY OK THEREFORE 10 AWG IS SUFFICIENT. AC WIRE SIZING MAX AC OUTPUT CURRENT = (MAX INVERTER OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] = 48 A X 1.25 = 60 A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] = 0.91 X 1 X 75A = 68.25A TERMINAL RATING[110.14(C)] = 6 AWG, RATED = 65A 65A < 68.25A → ADJUSTED CONDUCTOR AMPACITY GOVERNS CONDUCTOR SIZING. 60A < 65A → 6 AWG AMPACITY OK THEREFORE 6 AWG IS SUFFICIENT. SYSTEM CHARACTERISTICS MAX OPEN CIRCUIT VOLTAGE = {[((TEMP COEF VOC) X (VOC)) / 100] X [LOW TEMP - STC TEMP] + VOC} X (# MODULES / STRING) = {[(-0.26 %/°C X 37.05 V) / 100] X [-2 °C - 25 °C] + 37.05 V} X 10 = 397 V SHORT CIRCUIT CURRENT = 1.25 X (MODULE ISC) X (# STRINGS) 1.25 X 14.88 A X 1 = 18.6A F PV-4.3 #ESTAMP PANEL SCHEDULE PAGE REV: F 6/2/2025 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 EFREN LUMBRERAS 2100 E WELLINGTON AVE, SANTA ANA, CA, 92701 PROJECT NUMBER: 109R-100LUMB SHEET DESIGNER: KEVIN SIN CUSTOMER RESIDENCE: TEL. (949) 763-0025 APN: 400-153-29 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 50 20 200 60 ESS +PV BREAKER BEDROOM 1 LIGHTS AIR CON 15 15 15 BATHROOM 1 OUTLETS BATHROOM 1 LIGHTS GARAGE LIGHTS 20 20 PANEL SCHEDULE DISHWASHER 20 15 1520 KITCHEN LIGHTS REFRIDGERATOR 30DRYER 20 20 20 20 LIVING OUTLETS KITCHEN OUTLETS LIVING LIGHTS BEDROOM 1 OUTLETS2020 BATHROOM 2 OUTLETS BATHROOM 2 LIGHTS BEDROOM 2 LIGHTS BEDROOM 2 OUTLETS GARAGE OUTLETS FUTURE 225/200 MAIN PANEL F PAGE REV: F 6/2/2025 EFREN LUMBRERAS 2100 E WELLINGTON AVE, SANTA ANA, CA, 92701 PROJECT NUMBER: 109R-100LUMB SHEET DESIGNER: KEVIN SIN CUSTOMER RESIDENCE: TEL. (949) 763-0025 APN: 400-153-29 (415) 580-6920 ex3 Template_version_v5_2024.02.28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 SIGNAGE PV-5.0 #ESTAMP LABEL LOCATION: ENERGY STORAGE SYSTEM DISCONNECT PER CODE(S): NEC 2020: 706.15(C), CEC 2022: 706.15(C) WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS OCPD (IF APPLICABLE). PER CODE(S): NEC 2020: 705.12(B)(3)(2), CEC 2022: 705.12(B)(3)(2) NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2022 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): NEC 2020: 690.56(C), CEC 2022: 690.56(C) 4" 3" ELECTRICAL SHOCK HAZARD WARNING LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020: 690.13(B), CEC 2022: 690.13(B) ! INVERTER 1 PHOTOVOLTAIC DC DISCONNECT MAXIMUM SYSTEM VOLTAGE:VDC550 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53 LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2020: 690.31(D)(2), CEC 2022: 690.31(D)(2) PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10 LABEL LOCATION: INSTALLED WITHIN 3' OF RAPID SHUT DOWN SWITCH PER CODE(S): NEC 2020: 690.56(C)(2), CEC 2022: 690.56(C)(2), IFC 2018: 1204.5.3 WARNING! SOURCES: UTILITY GRID, BATTERY AND PV SOLAR ELECTRIC SYSTEM THREE POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): NEC 2020: 705.12(C), CEC 2022: 705.12(C)CAUTION: 2100 E WELLINGTON AVE, SANTA ANA, CA, 92701 SOLAR PANELS ON ROOF MULTIPLE SOURCES OF POWER LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54 PV SYSTEM DISCONNECT RAPID SHUTDOWN SWITCH SERVICE ENTRANCE AND TESLA BACKUP SWITCH INVERTER + BATTERY (INT) AC DISCONNECT (INT) F AC DISCONNECT (EXT)