HomeMy WebLinkAbout2100 E Wellington Ave - REV 1 - PlanPAGE
REV: A1 10/6/2024
EFREN LUMBRERAS
2100 E WELLINGTON AVE,
SANTA ANA, CA, 92701
PROJECT NUMBER:
109R-100LUMB
SHEET
DESIGNER:
HIMANSHU VASHIST
CUSTOMER RESIDENCE:
TEL. (949) 763-0025
APN: 400-153-29
(415) 580-6920 ex3
Template_version_v5_2024 02 28
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
COVER SHEET
SCOPE OF WORK GENERAL NOTES
PV-1.0
VICINITY MAP
LTD: LR5-54HABB-400M
SNR-DC-00450
1707000-XX-Y
(MCI) ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE
#SSTAMPCS
#ESTAMPCS
ABBREVIATIONS
A AMPERE
AC ALTERNATING CURRENT
AFC ARC FAULT CIRCUIT INTERUPTER
AZIM AZIMUTH
COMP COMPOSITION
DC DIRECT CURRENT
(E)EXISTING
ESS ENERGY STORAGE SYSTEM
MSP MAIN SERVICE PANEL
(N) NEW
PRE-FAB PRE-FABRICATED
PSF POUNDS PER SQUARE FOOT
PV PHOTOVOLTAIC
RSD RAPID SHUTDOWN DEVICE
TL TRANSFORMERLESS
V VOLTS
W WATTS
SHEET INDEX
PAGE # DESCRIPTION
PV-1.0 COVER SHEET
PV-2.0 SITE PLAN
PV-2.1 ESS ELEVATION VIEW
PV-3.0 LAYOUT
PV-3.1 MOUNTING DETAIL
PV-4.0 ELECTRICAL
PV-4.1 ELECTRICAL CALCS
PV-4.2 BACKUP LOAD CALCS
PV-4.3 PANEL SCHEDULE
PV-5.0 SIGNAGE
PV-5.1 SIGNAGE
NOTE: CEC 2022: 705.12(B)(3)(3): THIS EQUIPMENT FED BY
MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT
DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE
SHALL NOT EXCEED AMPACITY OF BUSBAR.
CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS.
SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.41(A).
MODULES, ARE CLASS A FIRE RATED.
CONDUCTORS OUTSIDE OF THE ARRAY ARE LIMITED TO LESS THAN 30V IN 30
SECONDS AND CEC 2022 690.12(B)(2)(2) WHERE CONDUCTORS INSIDE THE
ARRAY BOUNDARY IS LIMITED TO LESS THAN 80V IN 30 SECONDS
ROUTINE MAINTENANCE. SYSTEM VOLTAGE IN ACCORDANCE WITH CEC 706.20
AND EXCEPTION 1 CEC 706.20 (B).
CIRCUITS FROM THESE TERMINALS PASS THROUGH A WALL OR PARTITION PER
706.15(D).
CIRCUIT WIRING IS EXTENDED MORE THAN 6FT AND DOES NOT INCLUDE ANY
ADDITIONAL OUTLETS OR DEVICES PER CEC 210.12(D).
GREATER THAN THE LOAD POSED BY THE SINGLE LARGEST UTILIZATION
EQUIPMENT CONNECTED TO THE SYSTEM PER CEC ARTICLE 710.15(A)
31707000-XX-Y, 13.5 KWH.
***The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to
compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does
not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and
structures as shown. ***
Bldg#: 101121230
Elec#: 20184282
Approvals:
Elec: M Smith
2100 E Wellington
Ave11/18/2024
PAGE
REV: A1 10/6/2024
EFREN LUMBRERAS
2100 E WELLINGTON AVE,
SANTA ANA, CA, 92701
PROJECT NUMBER:
109R-100LUMB
SHEET
DESIGNER:
HIMANSHU VASHIST
CUSTOMER RESIDENCE:
TEL. (949) 763-0025
APN: 400-153-29
(415) 580-6920 ex3
Template_version_v5_2024 02 28
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
PL PL
PL
PL
PL
PL
PLPL
PL
PL
PL
PL
SITE PLAN
PV-2.0
#SSTAMPSP
#ESTAMPSP
NOTES:
RESIDENCE DOES NOT CONTAIN ACTIVE FIRE
SPRINKLERS.
ARRAY DETAILS:
TOTAL ROOF SURFACE AREA: 2500 SQFT.
TOTAL PV ARRAY AREA: 210.2 SQ FT.
PERCENTAGE PV COVERAGE:
(TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE
AREA) * 100 = 8.4%
ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS
IN ACCORDANCE WITH R328.4. ESS UNITS SHALL BE
SEPARATED FROM EACH OTHER BY NOT LESS THAN 3 FEET
EXCEPT WHERE SMALLER SEPARATION DISTANCES ARE
DOCUMENTED TO BE ADEQUATE BASED ON LARGE/SCALE
FIRE TESTING.
SITE PLAN - SCALE = 0'-0 1/16" = 1'-0"
(E) RESIDENCE
(N) ARRAY AR-01
FIRE SETBACKS
(18" TYP)
ROOF PATHWAYS
(3' TYP)
SE
MP
E WELLINGTON AVE
ROOF PATHWAYS
(3' TYP)
GPMD
ACINV
(E) FENCE
(E) CHIMNEY
(E) GATE(TYP.)
A
AA
A
A
A
A
A
AA
GENERATION PANEL
RAIL
STANDOFFS &
FOOTINGS
SOLAR
MODULES
SOLAREDGE METER
AC DISCONNECT(S)
PM
SE
MP MAIN PANEL
SERVICE ENTRANCE
SCALE: NTS
NOTE: NOT ALL ITEMS IN LEGEND
WILL APPEAR IN SITE PLAN
LEGEND SM
INV INVERTER(S)
AC
DC DISCONNECT(S)DEDICATED PV METER DC
SUB-PANELSP
LC PV LOAD CENTER SEM BACKUP LOADS PANEL
BACKUP INTERFACE
MICROGRID
INTERCONNECT DEVICE
AM
ENERGY STORAGE
SYSTEM METER ADAPTER
MD
BP
MA
BIACREL METER
ELECTRIC VEHICLE
SUPPLY EQUPMENTEV
CB IQ COMBINER BOX
1 COMMUNICATION
WIRES
GROUNDING
ELECTRODE
BACKUP GATEWAY
GP
BG
POWERWALL ENERGY
STORAGE SYSTEM (ESS)
INTERIOR EQUIPMENT
SHOWN AS DASHED
EXTERNAL RAPID
SHUTDOWN SWITCH
RSD
ARRAY
PITCH
PV AREA
(SQFT)
AR-01 17° 210.2
TRUE
AZIM
MAG
AZIM
259°271°
Signed 10/6/2024
2100 E Wellington
Ave11/18/2024
PAGE
REV: A1 10/6/2024
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
EFREN LUMBRERAS
2100 E WELLINGTON AVE,
SANTA ANA, CA, 92701
PROJECT NUMBER:
109R-100LUMB
SHEET
DESIGNER:
HIMANSHU VASHIST
CUSTOMER RESIDENCE:
TEL. (949) 763-0025
APN: 400-153-29
GILBERT CORREIA, C10, C46
CA CL #750184
(415) 580-6920 ex3
PV-2.1
GATE
EXTERIOR SOUTH WALL
MSP
GPBG
ACD
SITE PLAN - SCALE = NTS
ESS ELEVATION VIEW
ESS ELEVATION VIEW
PW3
ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS IN ACCORDANCE WITH R328.4.
ESS UNITS SHALL BE SEPARATED FROM EACH OTHER BY NOT LESS THAN 3 FEET EXCEPT
WHERE SMALLER SEPARATION DISTANCES ARE DOCUMENTED TO BE ADEQUATE BASED ON
LARGE/SCALE FIRE TESTING.
NO DWELLING DOORS OR WINDOWS ARE IN NEARBY
Signed 10/6/2024
2100 E Wellington
Ave11/18/2024
PAGE
REV: A1 10/6/2024
EFREN LUMBRERAS
2100 E WELLINGTON AVE,
SANTA ANA, CA, 92701
PROJECT NUMBER:
109R-100LUMB
SHEET
DESIGNER:
HIMANSHU VASHIST
CUSTOMER RESIDENCE:
TEL. (949) 763-0025
APN: 400-153-29
(415) 580-6920 ex3
Template_version_v5_2024 02 28
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
#SSTAMP
DESIGN CRITERIA
MAX DISTRIBUTED LOAD: 3 PSF
SNOW LOAD: 0 PSF
WIND SPEED:
96 MPH 3-SEC GUST.
FASTENERS:
(4) #14 S.S. SEALING WASHER
WOOD SCREWS FULLY
PENETRATING THROUGH WOOD
DECK
PV-3.0
LAYOUT
SOLAR MODULE
SNAPNRACK
RACKING
6"
MODULE ELEVATION DETAIL - SCALE: NTS
INSTALLERS SHALL NOTIFY ENGINEER OF ANY
POTENTIAL STRUCTURAL ISSUES OBSERVED
PRIOR TO PROCEEDING W/ INSTALLATION.
* IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12"
BOUNDARY REGION OF ANY ROOF PLANE
EDGES (EXCEPT VALLEYS), THEN
ATTACHMENTS NEED TO BE ADDED AND
OVERHANG REDUCED WITHIN THE 12"
BOUNDARY REGION ONLY AS FOLLOWS:
** ALLOWABLE ATTACHMENT SPACING
INDICATED ON PLANS TO BE REDUCED BY 50%.
** ALLOWABLE OVERHANG INDICATED ON
PLANS TO BE 1/5TH OF ALLOWABLE
ATTACHMENT SPACING INDICATED ON PLANS.
ROOF INFO ATTACHMENT INFORMATION
Name Type Height Detail Max Landscape
OC Spacing
Max Landscape
Overhang
Max Portrait
OC Spacing
Max Portrait
Overhang Configuration
AR-01 1-Story UR - SPEEDSEAL DECKFOOT TO WOOD DECK - SNR-DC-00450 4'-10" 0'-6" 4'-10" 0'-6"STAGGEREDCOMP SHINGLE SPEEDSEAL DECKFOOT
EXISTING STRUCTURE IS ASSUMED TO BE A LIGHT-FRAME WOOD ROOF
AND FREE FROM DAMAGE, DETERIORATION, OR MODIFICATION THAT
WOULD COMPROMISE ITS ORIGINAL DESIGN INTEGRITY. CONTACT
ENGINEER OF RECORD IF FOLLOWING MINIMUM REQUIREMENTS ARE NOT
SATISFIED IN COMPLIANCE WITH THE STATED RACKING DESIGN:
SEE SITE PLAN FOR NORTH ARROW
D1 - AR-01 - SCALE: 3/16" = 1'-0"
AZIM:271°
PITCH: 17°
28'-6"
11'-3"
3'-7"3'-6"
1'-7"
6"
Signed 10/6/2024
2100 E Wellington
Ave11/18/2024
PAGE
REV: A1 10/6/2024
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
EFREN LUMBRERAS
2100 E WELLINGTON AVE,
SANTA ANA, CA, 92701
PROJECT NUMBER:
109R-100LUMB
SHEET
DESIGNER:
HIMANSHU VASHIST
CUSTOMER RESIDENCE:
TEL. (949) 763-0025
APN: 400-153-29
GILBERT CORREIA, C10, C46
CA CL #750184
(415) 580-6920 ex3
MOUNTING DETAIL
PV-3.1
SNAPNRACK UR SPEEDSEAL DECKFOOT FOR COMPOSTION ROOF
MOUNTING ONTO WOOD DECKING
REFER TO SNAPNRACK ENGINEERING CHARTS FOR APPLICABLE
RAIL SPANS. "BIN" NUMBER ON CHART SHOULD MATCH "BIN"
NUMBER ON THIS DRAWING
(X4) #14 FULLY THREADED WOOD SCREWS, S.S. MUST EMBED
FULLY INTO WOOD DECK
REFER TO SNAPNRACK INSTALLATION MANUAL FOR 5
HARDWARE TORQUE SPECIFICATIONS
16"
RAIL CAN MOUNT ON EITHER SIDE OF SPEEDSEAL DECKFOOT.
SPEEDSEAL DECKFOOT CAN MOUNT UP, DOWN, OR ACROSS THE
SLOPE OF THE ROOF
FOR ADDITIONAL LEVELING DETAILS, REFER TO SNAPNRACK
DETAIL DRAWING "SNR-DC-00447 ULTRA RAIL, COMPONENT
DETAIL, ULTRA RAIL LEVELING SPACER"
BIN:
5
SNAPNRACK, SPEEDSEAL
DECKFOOT BASE, SEALING
SNAPNRACK, UR MOUNT
THRU
SNAPNRACK, UR MOUNT
TAPPED
EXPLODED
SNAPNRACK, ULTRA RAIL
TOP
COMP SHINGLE ROOFING, TYP.
3.860
16"-18 X 13
COIL SPRING FOR 3
4" BOLT,
SERRATED FLANGE, S.S.
8
BOLT, S.S. (OPTIONAL)
5.200
N/A REVISION:
1 1/13/2021 NEW DETAIL
2 4/5/2021 2PC CLAMP
MJA
MJA
MODULE HEIGHT, MAX:
UR-40 = 438"
UR-60 = 5"
SCREW HEIGHT
OFF ROOF:
9 16"
11
11 2"
21
15 8"
UR-40 RAIL | UR-60 RAIL
DESIGNER:
APPROVED BY:
M.AFFENTRANGER
DRAFTER: M.AFFENTRANGER
W.ARBUCKLE
SCALE:
DATE:
DNS
4/5/2021
DRAWING NUMBER:
SNR-DC-00450
REV:
2
4"
2"
MINIMUM DECK THICKNESS:
PLYWOOD:15/32"
ATTACHMENT DETAIL
SECTION VIEW
OSB: 7 16"
(4X) #14 FULLY THREADED
WOOD SCREW. S.S. MUST EMBED
FULLY INTO WOOD DECK
INSTALLATION OVERVIEW
ROOF DECKING, TYP.
Solar Mounting Solutions
Sunrun South LLC
595 MARKET STREET, 29TH FLOOR SAN FRANCISCO, CA 94105 USA
PHONE (415) 580-6900 FAX (415) 580-6902
THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY
REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE
WRITTEN CONSENT OF SUNRUN SOUTH LLC.
COMP SHINGLE ROOFING, TYP.
ROOF DECKING, TYP.
Signed 10/6/2024
2100 E Wellington
Ave11/18/2024
CONDUIT SCHEDULE
TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT
1 Inverter Input (2) 10 AWG (PV WIRE)N/A 6 AWG (BARE)Open Air
2 Inverter Input (2) 10 AWG
THHN/THWN-2 N/A 8 AWG THHN/THWN-2 3/4 EMT
3 Inverter Output (2) 6 AWG
THHN/THWN-2
(1) 6 AWG
THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT
4 Gateway Output (2) 3 AWG
THHN/THWN-2
(1) 3 AWG
THHN/THWN-2 8 AWG THHN/THWN-2 1 EMT
5 Backup Loads
(5) 12 AWG
THHN/THWN-2
(5) 12 AWG
THHN/THWN-2
8 AWG THHN/THWN-2 1-1/2 EMT
(11) 10 AWG
THHN/THWN-2
(11) 10 AWG
THHN/THWN-2
(2) 10 AWG
THHN/THWN-2
(1) 10 AWG
THHN/THWN-2
(2) 8 AWG
THHN/THWN-2
(1) 8 AWG
THHN/THWN-2
EXISTING 100A
MAIN BREAKER
END FED
EXISTING 100A
MAIN PANEL
100A BUS
M
100A
NEW 200A
BACKUP GATEWAY
1841000-X1-Y
4
J-BOX
LONGI GREEN ENERGY TECHNOLOGY CO LTD:
LR5-54HABB-400M
STRING 1 OF 10 MODULES
4 MODULE LEVEL
RAPID SHUTDOWN DEVICES
12
POINT OF INTERCONNECTION: CEC 2022 705.12(B)(3)(3), GATEWAY
BREAKER AT OPPOSITE END OF BUSBAR
METER
NUMBER: 222013-049004
EQUIPMENT CHARACTERISTICS
INCLUDED IN SPEC SHEETS
NOTE: TOTAL PV BACKFEED
= 60A USED FOR INTERCONNECTION CALCULATIONS
(N) LOCKABLE
BLADE TYPE
AC DISCONNECT
SQUARE D
DU222RB
3R, 60A,2P
120/240VAC
3
NEW\ 225 A
GENERATION PANEL AND
BACKUP LOAD PANEL
(N)- 60A ESS + PV BREAKER
4
FACILITY
GROUND
BACKUP
LOADS
5
3
TESLA
POWERWALL 3 1707000-XX-Y
TESLA: POWERWALL
3 1707000-XX-Y
11500 WATT
INVERTER
LOAD RATED DC
DISCONNECT WITH
AFCI RAPID
SHUTDOWN
COMPLIANT
PAGE
REV: B 10/25/2024
EFREN LUMBRERAS
2100 E WELLINGTON AVE,
SANTA ANA, CA, 92701
PROJECT NUMBER:
109R-100LUMB
SHEET
DESIGNER:
HIMANSHU VASHIST
CUSTOMER RESIDENCE:
TEL. (949) 763-0025
APN: 400-153-29
(415) 580-6920 ex3
Template_version_v5_2024.02.28
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
PV-4.0
ELECTRICAL
#ESTAMP
MODULE CHARACTERISTICS
LONGI GREEN ENERGY
TECHNOLOGY CO LTD:
LR5-54HABB-400M
400 W
OPEN CIRCUIT VOLTAGE 37.05 V
MAX POWER VOLTAGE 30.94 V
SHORT CIRCUIT CURRENT 14.88 A
INSTALLER MUST CHECK THE CONDITION, INSTALLABILITY AND CODE
COMPLIANCE OF EXISTING EQUIPMENT.
INSTALL THE BACKED UP LOAD CONDUCTORS AND THE GATEWAY BREAKER
CONDUCTORS IN TWO SEPARATE CONDUITS.
IF THE RELOCATED LOADS EXTEND MORE THAN 6 FEET, AFCI PROTECTION
APPLIES PER 2019 CEC 210.12
ANY MULTIWIRE BRANCH CIRCUITS RELOCATED ARE TO BE IDENTIFIED,
GROUPED, AND EQUIPPED WITH A 2-POLE OCPD BREAKER PER CEC 210.4(B,D).
GENERAL NOTES:
COLD WATER GAS BOND
B
B
2100 E Wellington
Ave11/18/2024
PAGE
REV: A1 10/6/2024
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
EFREN LUMBRERAS
2100 E WELLINGTON AVE,
SANTA ANA, CA, 92701
PROJECT NUMBER:
109R-100LUMB
SHEET
DESIGNER:
HIMANSHU VASHIST
CUSTOMER RESIDENCE:
TEL. (949) 763-0025
APN: 400-153-29
GILBERT CORREIA, C10, C46
CA CL #750184
(415) 580-6920 ex3
PV-4.1
ELECTRICAL CALCS
Template_version_v5_2024 02 28
ELECTRICAL CALCS
SYSTEM INFORMATION
4 KW DC PHOTOVOLTAIC SYSTEM
(10) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-400M, TESLA: POWERWALL 3 1707000-XX-Y
ALLOWABLE BACKFEED
ALLOWABLE BACKFEED = MAIN PANEL RATING =
100A
LOADS IN MAIN PANEL: 30A LOADS + 70A GATEWAY BREAKER = 100A ≤ 100A
INTERCONNECTION MEETS CEC 2022 705.12(B)(3)(3) REQUIREMENTS.
GATEWAY SYSTEM AC WIRE SIZING
MAX AC OUTPUT CURRENT = 70 A
ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =
0.91 X 1 X 95A = 86.45A
TERMINAL RATING[110.14(C)] =
4 AWG, 75°C RATED = 85A
85A < 86.45A TERMINAL RATING GOVERNS CONDUCTOR SIZING
70A < 85A 4 AWG AMPACITY OK
THEREFORE 4 AWG IS SUFFICIENT.
INVERTER OVERCURRENT PROTECTION
(INVERTER MAX CURRENT) X (CONTINUOUS LOAD) =
48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION PER MANUFACTURER
DC WIRE SIZING
MAX CIRCUIT CURRENT = (MODULE ISC) X (HIGH IRRADIANCE)[690.8(A)(1)] X (CONTINUOUS LOAD)[690.8(B)(1)]=
14.88A X 1.25 = 18.6A
ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =
0.91 X 1 X 40A = 36.4A
TERMINAL RATING[110.14(C)] =
10 AWG, RATED = 35A
35A < 36.4A → TERMINAL RATING GOVERNS CONDUCTOR SIZING.
18.6A < 35A → 10 AWG AMPACITY OK
THEREFORE 10 AWG IS SUFFICIENT.
AC WIRE SIZING
MAX AC OUTPUT CURRENT = (MAX INVERTER OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] =
48 A X 1.25 = 60 A
ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =
0.91 X 1 X 75A = 68.25A
TERMINAL RATING[110.14(C)] =
6 AWG, RATED = 65A
65A < 68.25A → ADJUSTED CONDUCTOR AMPACITY GOVERNS CONDUCTOR SIZING.
60A < 65A → 6 AWG AMPACITY OK
THEREFORE 6 AWG IS SUFFICIENT.
SYSTEM CHARACTERISTICS
MAX OPEN CIRCUIT VOLTAGE = {[((TEMP COEF VOC) X (VOC)) / 100] X [LOW TEMP - STC TEMP] + VOC} X (# MODULES / STRING) =
{[(-0.26 %/°C X 37.05 V) / 100] X [-2 °C - 25 °C] + 37.05 V} X 10 = 397 V
SHORT CIRCUIT CURRENT = 1.25 X (MODULE ISC) X (# STRINGS)
1.25 X 14.88 A X 1 = 18.6A
2100 E Wellington
Ave11/18/2024
BACKUP LOADS
LOAD BREAKER RATING
(AMPS)LABEL DEMAND LOAD(VA)
1 20A-1P GARAGE OUTLETS 1500 VA
2 20A-1P LIVING LIGHTS 1500 VA
3 20A-1P LIVING OUTLETS 1500 VA
4 20A-1P BEDROOM 1 OUTLETS 1500 VA
5 20A-1P BEDROOM 1 LIGHTS 1500 VA
6 20A-1P BEDROOM 2 OUTLETS 1500 VA
7 20A-1P BEDROOM 2 LIGHTS 1500 VA
8 20A-1P KITCHEN OUTLETS 1500 VA
9 20A-1P KITCHEN LIGHTS 1500 VA
10 20A-1P DISHWASHER 1500 VA
11 20A-1P REFRIDGERATOR 1500 VA
12 15A-1P BATH 1 LIGHTS 1500 VA
13 15A-1P BATH 1 OUTLETS 1500 VA
14 15A-1P BATH 2 LIGHTS 1500 VA
15 15A-1P BATH 2 OUTLETS 1500 VA
16 15A-1P GARAGE LIGHTS 1500 VA
17 30A-2P DRYER 5760 VA
18 50A-2P AC 4704 VA
BACKUP LOAD CALCS
PV-4.2
BACKUP LOAD CALCS
#ESTAMP
PAGE
REV: B 10/25/2024
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
EFREN LUMBRERAS
2100 E WELLINGTON AVE,
SANTA ANA, CA, 92701
PROJECT NUMBER:
109R-100LUMB
SHEET
DESIGNER:
HIMANSHU VASHIST
CUSTOMER RESIDENCE:
TEL. (949) 763-0025
APN: 400-153-29
GILBERT CORREIA, C10, C46
CA CL #750184
(415) 580-6920 ex3
Template_version_v5_2024.02.28
ALL BACKED UP LOADS ABOVE IN THE BACKED UP LOADS PANEL ARE RELOCATED FROM THE MAIN SERVICE PANEL.
BACKED UP LOADS CALCULATION:
(9600 VA)/ 240V = 19.6 A PER CEC 2022 ARTICLE 690.10 OR NEC 2020 ARTICLE 710.15.
THE MAXIMUM CURRENT FOR ALL LARGE APPLIANCES LOADS IS 40A.
(1500 VA)/ 120V = 12.5 A PER CEC 2022 ARTICLE 690.10 OR NEC 2020 ARTICLE 710.15.
THE MAXIMUM CURRENT FOR ALL SMALL APPLIANCES LOADS IS 12.5A.
(MAX LOADS OUTPUT) X (CONTINUOUS LOADS) =
19.6 A X 1.25 = 24.5A;
BACKED UP LOADS PANEL BREAKER = 70A
24.5 A < 70A
THEREFORE, THE AMPERAGE OF THE BACKED UP LOADS IS LESS THAN THAT OF THE OCPD.
AC WIRE SIZING FOR BACKED UP LOADS PANEL:
MAX AC OUTPUT CURRENT = (MAX LOADS OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] =
19.6 A X 1.25 = 24.5A
ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X
(CONDUCTOR AMPACITY)[TABLE 310.16] =
0.91 X 1 X 55A = 50.05A
TERMINAL RATING[110.14(C)] =
8 AWG, 75°C RATED = 50A
50A < 50.05A → TERMINAL RATING GOVERNS CONDUCTOR SIZING.
24.5A ≤ 50A → 8 AWG AMPACITY OK
THEREFORE 8 AWG IS SUFFICIENT.
AC WIRE SIZING FOR BACKED UP LOADS PANEL:
MAX AC OUTPUT CURRENT = (MAX LOADS OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] =
12.5 A X 1.25 = 15.625A
ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X
(CONDUCTOR AMPACITY)[TABLE 310.16] =
0.91 X 1 X 40A = 36.4A
TERMINAL RATING[110.14(C)] =
12 AWG, 75°C RATED = 35A
35A < 36.4A → TERMINAL RATING GOVERNS CONDUCTOR SIZING.
15.625A < 35A → 12 AWG AMPACITY OK
THEREFORE 12 AWG IS SUFFICIENT.
B
2100 E Wellington
Ave11/18/2024
PV-4.3
#ESTAMP
PANEL
SCHEDULE
PAGE
REV: B 10/25/2024
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
EFREN LUMBRERAS
2100 E WELLINGTON AVE,
SANTA ANA, CA, 92701
PROJECT NUMBER:
109R-100LUMB
SHEET
DESIGNER:
HIMANSHU VASHIST
CUSTOMER RESIDENCE:
TEL. (949) 763-0025
APN: 400-153-29
GILBERT CORREIA, C10, C46
CA CL #750184
(415) 580-6920 ex3
FUTURE 100/100
MAIN PANEL
FUTURE 225A GENERATION
& BACKUP LOADS PANEL
SCHEDULE
50
20
10
0
100
GATEWAY
FEEDER
BREAKER
60
ESS +PV
BREAKER
BEDROOM 1 LIGHTS
AIR CON
15
15
15
BATHROOM 1 OUTLETS
BATHROOM 1 LIGHTS
GARAGE LIGHTS
20
20
PANEL SCHEDULE
DISHWASHER
20
15
1520
KITCHEN LIGHTS
REFRIDGERATOR
30DRYER
20
20
20
20
LIVING OUTLETS
KITCHEN OUTLETS
LIVING LIGHTS BEDROOM 1 OUTLETS2020
BATHROOM 2 OUTLETS
BATHROOM 2 LIGHTS
BEDROOM 2 LIGHTS
BEDROOM 2 OUTLETS
GARAGE OUTLETS
B
2100 E Wellington
Ave11/18/2024
PAGE
REV: A1 10/6/2024
EFREN LUMBRERAS
2100 E WELLINGTON AVE,
SANTA ANA, CA, 92701
PROJECT NUMBER:
109R-100LUMB
SHEET
DESIGNER:
HIMANSHU VASHIST
CUSTOMER RESIDENCE:
TEL. (949) 763-0025
APN: 400-153-29
(415) 580-6920 ex3
Template_version_v5_2024 02 28
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
SIGNAGE
PV-5.0
#ESTAMP
ENERGY STORAGE SYSTEM
DISCONNECT
LABEL LOCATION:
ENERGY STORAGE SYSTEM DISCONNECT
PER CODE(S): NEC 2020: 706.15(C), CEC 2022: 706.15(C)
WARNING!
DO NOT RELOCATE THIS
OVERCURRENT DEVICE
POWER SOURCE OUTPUT CONNECTION
LABEL LOCATION:
ADJACENT TO PV BREAKER AND ESS
OCPD (IF APPLICABLE).
PER CODE(S): NEC 2020: 705.12(B)(3)(2),
CEC 2022: 705.12(B)(3)(2)
NOTES AND SPECIFICATIONS:
SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2022 ARTICLE
110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR
IF REQUESTED BY THE LOCAL AHJ.
SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
WORDS, COLORS AND SYMBOLS.
LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING
METHOD AND SHALL NOT BE HAND WRITTEN.
LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
INVOLVED.
SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY
SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.
DO NOT COVER EXISTING MANUFACTURER LABELS.
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
SOLAR ELECTRIC
PV PANELS
TURN RAPID SHUTDOWN
SWITCH TO THE "OFF"
POSITION TO SHUT DOWN
PV SYSTEM AND REDUCE
SHOCK HAZARD IN THE
ARRAY.
LABEL LOCATION:
ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE
DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
ARE CONNECTED.
PER CODE(S): NEC 2020: 690.56(C), CEC 2022: 690.56(C)
4"
3"
ELECTRICAL SHOCK HAZARD
WARNING
TERMINALS ON LINE AND LOAD
SIDES MAY BE ENERGIZED IN
THE OPEN POSITION
LABEL LOCATION:
INVERTER(S), AC/DC DISCONNECT(S),
AC COMBINER PANEL (IF APPLICABLE).
PER CODE(S): NEC 2020: 690.13(B), CEC
2022: 690.13(B)
!
INVERTER 1
PHOTOVOLTAIC DC DISCONNECT
MAXIMUM SYSTEM VOLTAGE:VDC550
LABEL LOCATION:
INVERTER(S), DC DISCONNECT(S).
PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53
WARNING: PHOTOVOLTAIC
POWER SOURCE
WARNING: PHOTOVOLTAIC
POWER SOURCE
LABEL LOCATION:
INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
AT EACH TURN, ABOVE AND BELOW PENETRATIONS,
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
PER CODE(S): NEC 2020: 690.31(D)(2), CEC 2022:
690.31(D)(2)
PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10
LABEL LOCATION:
INSTALLED WITHIN 3' OF RAPID SHUT DOWN
SWITCH PER CODE(S): NEC 2020: 690.56(C)(2),
CEC 2022: 690.56(C)(2), IFC 2018: 1204.5.3
RAPID SHUTDOWN SWITCH
FOR SOLAR PV SYSTEM
WARNING!
SOURCES: UTILITY GRID,
BATTERY AND PV SOLAR
ELECTRIC SYSTEM
THREE POWER SUPPLY
LABEL LOCATION:
UTILITY SERVICE METER AND MAIN
SERVICE PANEL.
PER CODE(S): NEC 2020: 705.12(C), CEC
2022: 705.12(C)CAUTION
2100 E WELLINGTON AVE, SANTA ANA, CA, 92701
SOLAR PANELS ON ROOF
MULTIPLE SOURCES OF POWER
BACKUP GATEWAY
GENERATION AND BACKUP LOADS PANEL
SERVICE ENTRANCE AND GATEWAY
FEEDER BREAKER
INVERTER + BATTERY (EXT)
MAXIMUM AC OPERATING CURRENT:
NOMINAL OPERATING AC VOLTAGE:
48 AMPS
240 VAC
LABEL LOCATION:
AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION.
PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54
PV SYSTEM DISCONNECT
THIS EQUIPMENT FED BY
MULTIPLE SOURCES. TOTAL
RATING OF ALL OVERCURRENT
DEVICES EXCLUDING MAIN
SUPPLY OVERCURRENT DEVICE
SHALL NOT EXCEED AMPACITY OF
BUSBAR
WARNING!
LABEL LOCATION:
PV LOAD CENTER (IF APPLICABLE) AND
ANY PANEL THAT UTILIZES "THE SUM
OF BREAKERS RULE".
PER CODE(S): NEC 2020: 705.12 (B)(3)(3),
CEC 2022: 705.12 (B)(3)(3)
2100 E Wellington
Ave11/18/2024
PAGE
REV: A1 10/6/2024
EFREN LUMBRERAS
2100 E WELLINGTON AVE,
SANTA ANA, CA, 92701
PROJECT NUMBER:
109R-100LUMB
SHEET
DESIGNER:
HIMANSHU VASHIST
CUSTOMER RESIDENCE:
TEL. (949) 763-0025
APN: 400-153-29
(415) 580-6920 ex3
Template_version_v5_2024 02 28
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
SIGNAGE
PV-5.1
#ESTAMP
ENERGY STORAGE SYSTEM
PREMISES WIRING MAY REMAIN
ENERGIZED AFTER LOSS OF
UTILITY POWER
C UTION!
LABEL LOCATION:
INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE).
PER CODE(S): CEC 2022: 706.15(C), NEC 2020: 706.15(C)
ENERGY STORAGE SYSTEM DISCONNECT
NOMINAL ESS VOLTAGE VAC
LABEL LOCATION:
MAIN PANEL.
120 240
NEC 2020 - PW3
PER CODE(S): NEC 706.15(C)
LABEL LOCATION:
BACKED UP LOADS PANEL
NO ADDITIONAL
LOADS TO BE
ADDED
2100 E Wellington
Ave11/18/2024
This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms
and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this
Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material,
product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This
Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
Intertek Page 1 of 8 GFT-OP-11a (22-August-2019)
Test Verification of Conformity
Verification Number: 104514208CRT-001VOC
Applicant Name & Address:
Tesla Inc.
3500 Deer Creek Road, Palo Alto, CA 94304
Product Description:
Energy Storage System Grid Support Utility Interactive & Standalone Inverter
Ratings & Principle
Characteristics:
See Appendix 2
Models/Type References:
1707000- followed by two numbers; followed by -; followed by one letter.
Brand Names:
Tesla
Relevant Standard(s) /
Specification(s):
See Appendix 1
Verification Issuing Office Name
& Address:
Intertek Testing Services NA, Inc.
3933 US Route 11, Cortland, NY 13045 USA
Date of Tests:
9/15/2022 to 4/23/2024
Test Report Number(s): 104514208CRT-001, 104514208CRT-001RRF, 104514208CRT-001TRS,
104514208CRT-010, 104514208CRT-012
Additional information in Appendix.
Signature
Name: Mukund Rana
Position: Sr. Staff Engineer
Date: 10th May 2024
On the basis of the tests undertaken, the samples of the below product have been found to comply with the
requirements of the referenced standards at the time the tests were carried out. This verification is part of the full
test report and should be read in conjunction with it.
This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms
and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this
Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material,
product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This
Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
Intertek Page 2 of 8 GFT-OP-11a (22-August-2019)
Appendix 1: Relevant Standard(s)/Specification(s)
Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources
[UL 1741:2021 Ed.3]
Grid Support Utility Interactive Equipment - Supplement SA to UL 1741:2021 Ed.3 - Inverters, Converters, Controllers
and Interconnection System Equipment for use with Distributed Energy Resources [UL 1741:2021 Ed.3 (Supplement
SA)]
Grid Support Utility Interactive Inverters and Converters Based Upon IEEE 1547:2018 & IEEE 1547.1:2020 -
Supplement SB to UL 1741:2021 Ed.3 - Inverters, Converters, Controllers and Interconnection System Equipment for
use with Distributed Energy Resources [UL 1741:2021 Ed.3 (Supplement SB)]
Energy Storage Systems and Equipment [ANSI/UL 9540:2020 Ed.2+R:09Apr2021]
Photovoltaic (PV) DC Arc-Fault Circuit Protection [UL 1699B:2018 Ed.1+R:18May2021]
Software in Programmable Components [UL 1998:2013 Ed.3+R:24Sep2018]
Tests For Safety-related Controls Employing Solid-state Devices [UL 991:2004 Ed.3+R:09Jun2010]
Batteries for Use in Stationary, Vehicle Auxiliary Power and Light Electric Rail (LER) Applications [ANSI/UL 1973:2018
Ed.2]
IEEE 1547:2018 - IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with
Associated Electric Power Systems Interfaces
IEEE 1547a:2020 - IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with
Associated Electric Power Systems Interfaces
Amendment 1: To Provide More Flexibility for Adoption of Abnormal Operating Performance Category III
IEEE 1547.1:2020 - IEEE Standard Conformance Test Procedures for Equipment Interconnecting Distributed Energy
Resources with Electric Power Systems and Associated Interfaces
Source requirements document UL 1741 (SRD) v2.0 – HECO
Electric Rule No.21-2020 Generating Facility Interconnections
Default New England Bulk System Area Settings Requirement
PRC-024-3 Frequency and Voltage Protection Settings for Generating Resources
GOVERNMENT OF PUERTO RICO PUBLIC SERVICE REGULATORY BOARD PUERTO RICO ENERGY BUREAU, Generating
Facility and Microgrid Interconnection Regulation (“Regulation”), July 2021
Power Conversion Equipment [CSA C22.2#107.1:2016 Ed.4+U1]
Interconnection of Distributed Energy Resources and Electricity Supply Systems [CSA C22.3#9:2020 Ed.2]
Photovoltaic Rapid Shutdown Systems [CSA C22.2#330:2023 Ed.2]
Safety Functions Incorporating Electronic Technology [CSA C22.2#0.8:2019 Ed.4]
2100 E Wellington
Ave11/18/2024
This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms
and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this
Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material,
product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This
Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
Intertek Page 3 of 8 GFT-OP-11a (22-August-2019)
Appendix 2: Ratings & Principle Characteristics:
➢ Ratings:
Models 1707000-xx-y
Rated AC Output Power (W) 11500, 10000, 7680, 5750
Rated AC Input Power (W) Charging 5000
Max. Cont. Output Power (W) 11500, 10000, 7680, 5750
Max. Continuous Output PV to AC
Power Off-Grid (W) 15400
Max. Cont. Input Power (W) Charging 5000
AC Input / Output Voltage
(VL-L) 240
AC Output Frequency
(Hz) 60
Max. Cont. Output Current (A) 48, 4 1.6, 32, 24
Max. Cont. Input Current (A) Charging 20.83
Apparent Power rating (VA) 11500, 10000, 7680, 5750
Apparent Power rating (VA) Charging 5000
Normal Category A, B
Abnormal Category II, III
➢ Communication Protocol: IEEE 2030.5 protocol
➢ PCH board MD5 Firmware checksum: c5773b136a9ef9be9057302a67258482
➢ TACO board MD5 Firmware checksum: dcq8OiBXbQWYnK9UhCAjvl02/py2MZymmwAQYOn8jSc=
➢ Grid Support Function Parameters:
Tesla used the parameters in the Result reporting form “104514208CRT-001RRF” during the testing of the grid
support functions according to UL1741 SB. The parameters that have “blank” as their value are not applicable.
➢ UL 1998 and CSA C22.2#0.8 Evaluation:
ECU / Board Rev Software version Checksum UL1998, CSA C22.2#0.8
Compliant*
Date of evaluation
HVP / -E V2 51705DB5 Yes Apr-19-2024
PWS / -3F V2 34204954 Yes Apr-19-2024
PWS / -1F V2 B3C1375B Yes Apr-19-2024
PWS / -D V2 43FEF523 Yes Apr-19-2024
*Note: Below safety functions were evaluated during the UL1998 and UL 991 evaluation.
• List of all UL1998 and UL 991 functions are as follow:
o Overcharge
o Over-discharge
o Over Temperature
o Over current
o Relay weld, Isolation Monitoring Interruption, PV RSD (UL 1741)
o AFCI (UL 1699B)
This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms
and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this
Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material,
product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This
Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
Intertek Page 4 of 8 GFT-OP-11a (22-August-2019)
2100 E Wellington
Ave11/18/2024
This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms
and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this
Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material,
product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This
Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
Intertek Page 5 of 8 GFT-OP-11a (22-August-2019)
Appendix 3: List of Tested Grid protection / Support Function:
Table 3A: Test List -1
Grid protection / Support
Function Tested
Test Standards Sections and Source Requirement Documents
IEEE 1547-
2018
IEEE 1547.1-
2020
UL 1741SB -
2021 CA Rule 21:2020
UL 1741 SRD
V2.0
(HECO):2020
OPERATIONAL TEMPERATURE -- 5.3.3.1 SB4.3.5.3 -- Same as 1547-
2018
PROTECTION FROM
ELECTROMAGNETIC
INTERFERENCE (EMI) TEST
4.11.1 5.8.1 SB4.3.5.8.1 -- Same as 1547-
2018
SURGE WITHSTAND
PERFORMANCE TEST 4.11.2 5.8.2 SB4.3.5.8.2 -- Same as 1547-
2018
PARALLELING DEVICE 4.11.3 5.8.3 -- -- Same as 1547-
2018
OVERVOLTAGE TRIP 6.4.1 5.4.2 SB4.3.5.4.2 Electric Rule No.
21 Table Hh.1
Same as 1547-
2018
UNDERVOLTAGE TRIP 6.4.1 5.4.3 SB4.3.5.4.3 Electric Rule No.
21 Table Hh.1
Same as 1547-
2018
OVERFREQUENCY TRIP 6.5.1 5.5.1 & 5.5.2
SB4.3.5.5.1
&
SB4.3.5.5.2
Electric Rule No.
21 Table Hh.2
Same as 1547-
2018
UNDERFREQUENCY TRIP 6.5.1 5.5.1 & 5.5.2
SB4.3.5.5.1
&
SB4.3.5.5.2
Electric Rule No.
21 Table Hh.2
Same as 1547-
2018
LOW VOLTAGE RIDE-THROUGH 6.4.2.3 &
6.4.2.5 5.4.4 SB4.3.5.4.4 Electric Rule No.
21 Table Hh.1
Same as 1547-
2018
HIGH VOLTAGE RIDE-THROUGH 6.4.2.4 5.4.7 SB4.3.5.4.7 Electric Rule No.
21 Table Hh.1
Same as 1547-
2018
LOW FREQUENCY RIDE-THROUGH 6.5.2.3 5.5.3 SB4.3.5.5.3 Electric Rule No.
21 Table Hh.2
SRD-UL-1741-SA-
V2.0 (HECO) Part
II B
HIGH FREQUENCY RIDE-
THROUGH 6.5.2.4 5.5.4 SB4.3.5.5.4 Electric Rule No.
21 Table Hh.2
SRD-UL-1741-SA-
V2.0 (HECO) Part
II B
RATE OF CHANGE OF FREQUENCY 6.5.2.5 5.5.5 -- -- Same as 1547-
2018
ANTI-ISLANDING PROTECTION -
WITH GRID SUPPORT FUNCTIONS
ENABLED
8.1 5.10.2 SB4.3.5.10.2 Electric Rule No.
21 Hh.1a
According to UL
1741 SA-V2.0
(HECO)
TEST FOR VOLTAGE PHASE-ANGLE
CHANGE RIDE-THOUGH
(VARIATION 1)
6.5.2.6 5.5.6.1 SB4.3.5.5.6 -- Same as 1547-
2018
ENTER SERVICE 4.10 5.6 -- -- Same as 1547-
2018
SYNCHRONIZATION CONTROL
FUNCTION TEST FOR EQUIPMENT
WITH NO SYNCHRONIZING
DISABLE CAPABILITY (VARIATION
3)
6.3 5.7.4 -- -- Same as 1547-
2018
LIMITATION OF DC INJECTION
FOR INVERTERS 7.1 5.9 -- Electric Rule No.
21 Hh.2h
Same as 1547-
2018
OPEN PHASE 6.2.2 5.11 -- -- Same as 1547-
2018
CURRENT DISTORTION 7.3 5.12 -- Electric Rule No. Same as 1547-
This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms
and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this
Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material,
product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This
Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
Intertek Page 6 of 8 GFT-OP-11a (22-August-2019)
Grid protection / Support
Function Tested
Test Standards Sections and Source Requirement Documents
IEEE 1547-
2018
IEEE 1547.1-
2020
UL 1741SB -
2021 CA Rule 21:2020
UL 1741 SRD
V2.0
(HECO):2020
21 Hh.2g 2018
LIMIT ACTIVE POWER 4.6.2 5.13 -- Electric Rule No.
21 Hh.8
Same as 1547-
2018
CONSTANT POWER FACTOR 5.3.2 5.14.3 SB4.3.5.14.3 Electric Rule No.
21 Hh.2i
Same as 1547-
2018
VOLTAGE-REACTIVE POWER
(VOLT-VAR) MODE FIXED VREF 5.3.3 5.14.4 SB4.3.5.14.4 Electric Rule No.
21 Hh.2J
Same as 1547-
2018
VOLTAGE-REACTIVE POWER
(VOLT-VAR) MODE (VREF TEST) 5.3.3 5.14.5 SB4.3.5.14.5 -- Same as 1547-
2018
ACTIVE POWER-REACTIVE POWER
MODE (WATT-VAR) 5.3.4 5.14.7 SB4.3.5.14.7 -- Same as 1547-
2018
CONSTANT REACTIVE POWER
(VAR) MODE 5.3.5 5.14.8 SB4.3.5.14.8 -- Same as 1547-
2018
VOLTAGE-ACTIVE POWER (VOLT-
WATT) MODE 5.4 5.14.9 SB4.3.5.14.9 Electric Rule No.
21 Hh.2.m
Same as 1547-
2018
TEST FOR FREQUENCY -DROOP
(FREQUENCY-POWER OR
FREQUENCY-WATT) CAPABILITY —
ABOVE NOMINAL FREQUENCY
6.5.2.7 5.15.2 SB4.3.5.15.2 Electric Rule No.
21 Hh.2.l
SRD-UL-1741-SA-
V2.0 (HECO) Part
II C
TEST FOR FREQUENCY -DROOP
(FREQUENCY-POWER OR
FREQUENCY-WATT) CAPABILITY —
BELOW NOMINAL FREQUENCY
6.5.2.7 5.15.3 SB4.3.5.15.3 Electric Rule No.
21 Hh.2.l
SRD-UL-1741-SA-
V2.0 (HECO) Part
II C
PRIORITIZATION OF DER
RESPONSES 4.7 5.16 SB4.3.5.16 -- Same as 1547-
2018
LOAD REJECTION OVERVOLTAGE
(LROV) 7.4 5.17.2 SB4.3.5.17.2 -- Same as 1547-
2018
FAULT CURRENT TESTS FOR
INVERTERS 6.2.1 5.18.1 -- -- Same as 1547-
2018
PERSISTENCE OF DER PARAMETER
SETTINGS -- 5.19 -- -- Same as 1547-
2018
NORMAL RAMP RATE -- -- -- Electric Rule No.
21 Hh.2k --
NAMEPLATE DATA TEST 10.3 6.4 -- -- Same as 1547-
2018
MONITORING INFORMATION
TEST 10.5 6.6 SB4.3.6.6 -- Same as 1547-
2018
MANAGEMENT INFORMATION
TEST 10.6 6.7 SB4.3.6.7 -- Same as 1547-
2018
2100 E Wellington
Ave11/18/2024
2100 E Wellington
Ave11/18/2024
Powerwall 3
Power Everything
2024
—
Powerwall 3 is a fully integrated solar and battery system, designed to accelerate the transition to sustainable energy. Customers
can receive whole home backup, cost savings, and energy independence by producing and consuming their own energy while
participating in grid services. Once installed, customers can manage their system using the Tesla App to customize system
behavior to meet their energy goals.
Powerwall 3 achieves this by supporting up to 20 kW DC of solar and providing 11.5 kW AC of continuous power per unit. It has
the ability to start heavy loads up to 185 A LRA, meaning a single unit can support the power needs of most homes. Powerwall 3
is designed for mass production,fast and efcient installations,easy system expansion,and simple connection to any electrical
service.
22024Powerwall 3 Datasheet
Solar Technical
Specications
Maximum Solar STC Input 20 kW
Withstand Voltage 600 V DC
PV DC Input Voltage Range 60 — 550 V DC
PV DC MPPT Voltage Range 60 — 480 V DC
MPPTs 6
Maximum Current per MPPT (Imp)13 A 5
Maximum Short Circuit Current per MPPT (Isc)15 A 5
Powerwall 3 Technical Specifications
1 Typical solar shifting use case.
2 Values provided for 25°C (77°F), at beginning of life. 3.3 kW charge/discharge power.
3 Tested using CEC weighted efciency methodology.
4 The customer is expected to provide internet connectivity for Powerwall 3;cellular should not be used as the primary mode of
connectivity. Cellular connectivity subject to network operator service coverage and signal strength.
5 Where the DC input current exceeds the MPPT rating,a jumper can be used to combine two MPPTs into a single input to
intake DC current up to 26 A IMP / 30 A ISC.
Battery Technical
Specications
Nominal Battery Energy 13.5 kWh AC 2
Maximum Continuous Discharge Power 11.5 kW AC
Maximum Continuous Charge Power 5 kW AC
Output Power Factor Rating 0 -1 (Grid Code congurable)
Maximum Continuous Current 48 A
Maximum Output Fault Current 10 kA
Load Start Capability (1 s)185 A LRA
Power Scalability Up to 4 Powerwall 3 units supported
System Technical
Specications
Model Number 1707000-xx-y
Nominal Grid Voltage (Input &Output)120/240 VAC
Grid Type Split phase
Frequency 60 Hz
Overcurrent Protection Device 60 A
Solar to Battery to Home/Grid Efciency 89% 1,2
Solar to Home/Grid Efciency 97.5% 3
Supported Islanding Devices Gateway 3, Backup Switch, Backup Gateway 2
Connectivity Wi-Fi (2.4 and 5 GHz), Dual-port switched Ethernet,
Cellular (LTE/4G 4)
Hardware Interface Dry contact relay,Rapid Shutdown (RSD)certied switch
and 2-pin connector, RS-485 for meters
AC Metering Revenue Grade (+/- 0.5%)
Protections Integrated arc fault circuit interrupter (AFCI), Isolation
Monitor Interrupter (IMI),PV Rapid Shutdown (RSD)using
Tesla Mid-Circuit Interrupters
Customer Interface Tesla Mobile App
Warranty 10 years
2100 E Wellington
Ave11/18/2024
2100 E Wellington
Ave11/18/2024
!"#!$
%$&
'
(
)( *+ ,-
((* ,
. ) ./
( *
00+&1&2!!
%
.
.3(
4
/
*4
.
.3 #!5$
/
.(
/(
671
.(
.3 %$&
..
*8
./)(
..
4
*.
((
(.
%. .3*8
/
-)
/(
(
(..
.3
*
.3
.
( *
"(
3
.3 !"$
9
$:222$&
(-.-
$: 222$&88
-8(
-
.
*
:;#2615--<72715.=
3 2#!5--<;2#&5.=
8 ;1215--<&2715.=
3
..3 >
&2;152-<&15()/2.=!2!!?!2!:5.@<2!6?12#5--@=$: 222$:!=
&2;152-<&15()/2.=$: 222$:!=
12!652-< 15()/2.=!2!:5.@<62&75--@=$6=
12!652-< 15()/2.=!2!?!2!&5.@<:2&?:2:5--@=$#222$ =
12#152-<1!5()/2.=!2! 5.@<#2#75--@=$&=
.3
.88.3
(
3*!!:!#AB%$&B&!!!$
.
(
:$
(
-
+
-
.
.
.
.
.
)
/
.
.
)
/
-
.
.
3
)
(
*
(
)
(
*
/
8
/
8
/
8
8
(
.
Feb 3, 2020
:
!!761;!: ;: ;:
,
3
4
3 <)=2::5,3< 2#15()<==
.
)( *C
. */3.%D
//
.
)( *
.
)(
//
.
--8
(/.
88 .#1 $+8
.
E8
*
-
(.(.3+
.(
-8.4
,.4.
/
(/.
.3
.A
8 '
-2-
./-
.3
44428#14
..32
23'
$
3(
.$
(
.
$/
/"C
'
-8(
.
(
.
E
'*-
(/
C
%
*/
C
E
-8 ../-
.C
.
3(
..
(
.
'
.
(
.< /.
(
3
(8
=
.'.-
.
((
.'.-
.
(/(
(
*/(
.
/8
/
*(.38
.
.
(4
. *
. *:6-.
2100 E Wellington
Ave11/18/2024
32024Powerwall 3 Datasheet
Mechanical
Specications
Dimensions 1099 x 609 x 193 mm (43.25 x 24 x 7.6 in)
Weight 130 kg (287 lb)
Mounting Options Floor or wall mount
Powerwall 3 Technical Specifications
Environmental
Specications
Operating Temperature –20°C to 50°C (–4°F to 122°F) 6
Operating Humidity (RH)Up to 100%, condensing
Storage Temperature –20°C to 30°C (–4°F to 86°F), up to 95% RH, non-
condensing, State of Energy (SOE): 25% initial
Maximum Elevation 3000 m (9843 ft)
Environment Indoor and outdoor rated
Enclosure Rating NEMA 3R
Ingress Rating IP67 (Battery & Power Electronics)
IP45 (Wiring Compartment)
Pollution Rating PD3
Operating Noise @ 1 m < 50 db(A) typical
<62 db(A)maximum
Compliance
Information
Certications UL 1642, UL 1699B, UL 1741, UL 1741 SA, UL 1741 SB, UL
1741 PCS, UL 3741, UL 1973, UL 1998, UL 9540, IEEE 1547-
2018, IEEE 1547.1, UN 38.3
Grid Connection United States
Emissions FCC Part 15 Class B
Environmental RoHS Directive 2011/65/EU
Seismic AC156, IEEE 693-2005 (high)
Fire Testing Meets the unit level performance criteria
of UL 9540A
6 Performance may be de-rated at operating temperatures above 40°C (104°F).
609 mm 193
mm
1099 mm
42024Powerwall 3 Datasheet
Electrical
Specications
Model MCI-1 MCI-2
Nominal Input DC Current Rating (IMP)13 A 13 A
Maximum Input Short Circuit Current (ISC)19 A 17 A
Maximum System Voltage (PVHCS)600 V DC 1000 V DC 7
Solar Shutdown Device Technical Specifications
Environmental
Specications
Operating Temperature -40°C to 50°C
(-40°F to 122°F)
-45°C to 70°C
(-49°F to 158°F)
Storage Temperature –30°C to 70°C
(–22°F to 158°F)
–30°C to 70°C
(–22°F to 158°F)
Enclosure Rating NEMA 4X /IP65 NEMA 4X /IP65
RSD Module
Performance
Maximum Number of Devices per String 5 5
Control Power Line Excitation Power Line Excitation
Passive State Normally Open Normally Open
Maximum Power Consumption 7 W 7 W
Warranty 25 years 25 years
—
The Solar Shutdown Device is a Mid-Circuit Interrupter (MCI)and is part of the PV system rapid shutdown (RSD)function in
accordance with Article 690 of the applicable NEC. When paired with Powerwall 3, solar array shutdown is initiated by any loss
of AC power.
Mechanical
Specications
Electrical Connections MC4 Connector MC4 Connector
Housing Plastic Plastic
Dimensions 125 x 150 x 22 mm
(5 x 6 x 1 in)
173 x 45 x 22 mm
(6.8 x 1.8 x 1 in)
Weight 350 g (0.77 lb) 120 g (0.26 lb)
Mounting Options ZEP Home Run Clip
M4 Screw (#10)
M8 Bolt (5/16")
Nail / Wood screw
Wire Clip
Compliance
Information
Certications UL 1741 PVRSE, UL 3741,
PVRSA (Photovoltaic Rapid Shutdown Array)
RSD Initiation Method External System Shutdown Switch or
Powerwall 3 Enable Switch
7 Maximum System Voltage is limited by Powerwall to 600 V DC.
UL 3741 PV Hazard Control
(and PVRSA)Compatibility See Powerwall 3 Installation Manual
2100 E Wellington
Ave11/18/2024
52024Powerwall 3 Datasheet
Gateway 3
8 Only Eaton CSR or BWH main breakers are 25 kA rated.
Performance
Specications
Model Number 1841000-01-y
Nominal Grid Voltage 120/240 V AC
Grid Conguration Split phase
Grid Frequency 60 Hz
Continuous Current
Rating
200 A
Maximum Supply Short
Circuit Current
22 kA with Square D or
Eaton main breaker
25 kA with Eaton main
breaker 8
IEC Protective Class Class I
Overvoltage Category Category IV
Mechanical
Specications
Dimensions 660 x 411 x 149 mm
(26 x 16 x 6 in)
Weight 16.3 kg (36 lb)
Mounting options Wall mount
Environmental
Specications
Operating Temperature –20°C to 50°C (–4°F to 122°F)
Operating Humidity (RH)Up to 100%, condensing
Maximum Elevation 3000 m (9843 ft)
Environment Indoor and outdoor rated
Enclosure Type NEMA 3R
Compliance
Information
Certications UL 67, UL 869A, UL 916, UL 1741 PCS,
CSA 22.2 107.1, CSA 22.2 29
Emissions FCC Part 15, ICES 003
—
Tesla Gateway 3 controls connection to the grid in a Powerwall system, automatically detecting outages and providing seamless
transition to backup power. It provides energy monitoring that is used by Powerwall for solar self-consumption, time-based
control, and backup operation.
411 mm
660
mm
149
mm
AC Meter Revenue accurate (+/- 0.5%)
Communication CAN
User Interface Tesla App
Backup Transition Automatic disconnect for
seamless backup
Overcurrent
Protection Device
100–200 A
Service entrance rated
Eaton CSR, BWH, or BW, or
Square D QOM breakers
Internal Panelboard 200 A
8-space/16 circuit breakers
Eaton BR, Siemens QP, or
Square D HOM breakers rated
to 10–125A
Warranty 10 years
62024Powerwall 3 Datasheet
Backup Switch
9 Breaker maximum supply short circuit current rating must be equal to or greater than the available fault current.
Performance
Specications
Model Number 1624171-xx-y
Continuous Load Rating 200 A, 120/240 V split phase
Maximum Supply Short Circuit Current 22 kA with breaker 9
Communication CAN
AC Meter Revenue accurate (+/- 0.5%)
Expected Service Life 21 years
Warranty 10 years
Mechanical
Specications
Dimensions 176 x 205 x 74 mm (6.9 x 8.1 x 2.9 in)
Weight 2.8 lb
Meter and Socket Compatibility ANSI Type 2S, ringless or ring type
External Service Interface Contactor manual override 10
Reset button
Conduit Compatibility 1/2-inch NPT
Environmental
Specications
Operating Temperature –40°C to 50°C (–40°F to 122°F)
Storage Temperature –40°C to 85°C (–40°F to 185°F)
Enclosure Rating NEMA 3R
Pollution Rating PD3
Compliance
Information
Safety Standards USA: UL 414, UL 414 SB, UL 2735, UL 916, CA Prop 65
Emissions FCC, ICES
10 Manually overrides the contactor position during a service event.
—
The Tesla Backup Switch controls connection to the grid in a Powerwall system, and can be easily installed behind the utility
meter or in a standalone meter panel downstream of the utility meter.
The Backup Switch automatically detects grid outages, providing a seamless transition to backup power. It communicates
directly with Powerwall, allowing home energy usage monitoring from any mobile device with the Tesla app.
204.86
74
176 mm
205 mm
74 mm
2100 E Wellington
Ave11/18/2024
72024Powerwall 3 Datasheet
Backup Gateway 2
Performance
Specications
Model Number 1232100-xx-y
AC Voltage (Nominal)120/240 V
Feed-in Type Split phase
Grid Frequency 60 Hz
Current Rating 200 A
Maximum Supply Short
Circuit Current
10 kA 11
Overcurrent Protection
Device
100 - 200 A, Service
entrance rated 9
Overvoltage Category Category IV
Internal Primary
AC Meter
Revenue accurate
(+/- 0.2%)
Internal Auxiliary
AC Meter
Revenue accurate
(+/- 2%)
Primary Connectivity Ethernet, Wi-Fi
Secondary Connectivity Cellular (3G, LTE/4G) 12
Mechanical
Specications
Dimensions 660 x 411 x 149 mm
(26 x 16 x 6 in)
Weight 20.4 kg (45 lb)
Mounting options Wall mount,
Semi-Bush mount
Environmental
Specications
Operating Temperature –20°C to 50°C (–4°F to 122°F)
Operating Humidity (RH)Up to 100%, condensing
Maximum Elevation 3000 m (9843 ft)
Environment Indoor and outdoor rated
Enclosure Type NEMA 3R
Compliance
Information
Certications UL 67, UL 869A, UL 916, UL 1741 PCS,
CSA 22.2 0.19, CSA 22.2 205
Emissions FCC Part 15, ICES 003
411 mm
660 mm
149
mm
11 When protected by Class J fuses, Backup Gateway 2 is
suitable for use in circuits capable of delivering not more
than 22kA symmetrical amperes.
12 Cellular connectivity subject to network operator service
coverage and signal strength.
—
Backup Gateway 2 controls connection to the grid when paired with Powerwall 3, automatically detecting outages and providing
seamless transition to backup power. Backup Gateway 2 also provides energy metering for solar self-consumption, time-based
control, and backup operation.
In this system conguration,Powerwall 3 acts as the Site Controller,with the Backup Gateway 2 Site Controller disabled.
User Interface Tesla App
Operating Modes Support for solar self-
consumption, time-based
control, and backup
Backup Transition Automatic disconnect for
seamless backup
Modularity Supports up to 10 AC-
coupled Powerwalls
Optional Internal
Panelboard
200 A 6-space / 12 circuit
breakers
Siemens QP or Square D
HOM breakers rated 10 -
80A or Eaton BR breakers
rated 10 - 125A
Warranty 10 years
82024Powerwall 3 Datasheet
Powerwall 3 Example System Configurations
Powerwall 3 with Backup Switch
Whole Home Backup
Powerwall 3 with Gateway 3
Whole Home Backup
Powerwall 3 with Backup Gateway 2
Partial Home Backup
2100 E Wellington
Ave11/18/2024
This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms
and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this
Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material,
product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This
Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
Intertek Page 7 of 8 GFT-OP-11a (22-August-2019)
Table 3B: Test List -2
Test Description
CSA
C22.2#107.1:2016
Ed. 4 CSA C22.3#9:2020 Ed 2
Screw Tightening Torque Test 3.6.3 --
Impedance Test 105.1/10.5.2 --
Continuity Test 4.1 --
Output Power Factor 4.2 --
Voltage Harmonics for stand alone 15.3.2.1 --
Frequency 10.5.4 --
Stand-alone inverter dc output short-circuits current contribution 10.5.5 --
Normal ramp rate -- 7.2.3.4.2 / 8.3.12.2.3
Flicker -- 7.2.2 / 8.3.13
Test for constant reactive power (var) mode 7.2.3.3.3 / 8.3.12.2.2
This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms
and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this
Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material,
product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This
Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
Intertek Page 8 of 8 GFT-OP-11a (22-August-2019)
Appendix 4: Revision Summary
Date /
Project Engineer Comments
15-Feb-2023 Dipesh Patel Original issue date
8-Mar-2023 /
G104200718
Dipesh Patel Added UL 1699B, UL 1998 and UL 991 standards
24-Mar-2023/
G104200718
Dipesh Patel Added UL 1973 standard.
Added normal and abnormal category in ratings table.
18-Apr-2023 /
G104200718
Dipesh Patel Added additional factory settable nameplate ratings rated output active
power (W): 9600, 7680, 5750; Max. Continuous output power (W):
9600, 7680, 5750; Max. Cont. Output Current (A): 40, 32, 24; Apparent
Power rating (VA): 9600, 7680, 5750
Added Puerto Rico Interconnection regulation as it refers to UL 1741
and IEEE 1547-2018.
1-May-2024 /
G104514208
Mukund Rana
A) Added standards.
Power Conversion Equipment [CSA C22.2#107.1:2016 Ed.4+U1]
Interconnection of Distributed Energy Resources and Electricity Supply
Systems [CSA C22.3#9:2020 Ed.2]
Photovoltaic Rapid Shutdown Systems [CSA C22.2#330:2023 Ed.2]
Interconnection of Distributed Energy Resources and Electricity Supply
Systems [CSA C22.3#9:2020 Ed.2]
B) Update CSA C22.2#0.8 standard
C) added Table 3B: Test List -2
2100 E Wellington
Ave11/18/2024
Service Voltage
240
Section 220.83 Existing Dwelling Unit
Part #1 - Section 220.83 (B)(1) General Lighting/Receptacles @ 3 VA per sq ft:
Amps Box A (VA)
31.25 7500
Part #2 - Section 220.83(B)(2), (3)a, b, c, d - Appliances and Dedicated Circuits:
Size in VA Size in VA
1500
1500
1500
1000
600
1000
1600
Amps Box B (VA)
36.25 8700
Total VA from Parts #1 and #2 combined:Box A + Box B =16200
Total VA 16200
First 8000 VA @ 100%8000 Remaining VA @ 40%
Remaining VA =8200 8200 x 40% =3280 VA
Adding First 8000 VA, if possible 8000 VA
Total VA for Gen. Lights/Recep, Appliances & Dedicated circuits:11280 VA
Total AMP for Gen. Lights/Recep, Appliances & Dedicated circuits:47.00 Amps
Part #3 - Section 220.83(B) Heating and A/C loads:
*Combine the larger loads of either the Heating or the A/C loads togther
100% of all the Heating or A/C loads in VA:4,704 VA
100% of all the Heating or A/C loads in Amps:19.60 A
VA Volts Amps
Parts #1 & #2 11280 240 47.00
Part #3 4,704 240 19.60
Total VA for all Parts:15,984
Totals Service/Feeder Load 66.60
Dedicated circuit Dedicated circuit
Article 220 - Dedicated Backup Panel Calculation Job Code
2100 E Wellington Ave Santa Ana CA USA 92701 109R-100LUMB
Building Square Footage VA (watts)Amps
House 2500.00 7500 31.25
Total for Part #1:
Laundry
Appliance Circuit - 1
Appliance Circuit - 2
Dishwasher
Disposal
Refrigerator
Microwave
Totals for Part #2:
Totals from all Parts
2100 E Wellington
Ave11/18/2024
Section 220.83 Existing Dwelling Unit
Part #1 - Section 220.83 (B)(1) General Lighting/Receptacles @ 3 VA per sq ft:
Amps Box A (VA)
31.25 7500
Part #2 - Section 220.83 (B)(2),(3)a, b, c, d - Appliances and Dedicated Circuits:
Size in VA Size in VA
1500 N/A
3000 N/A
1000 N/A
600 N/A
1000 N/A
1600 N/A
5760 N/A
N/A N/A
N/A N/A
N/A Amps Box B (VA)
N/A 60.25 14460
Total VA from Parts #1 and #2 combined:Box A + Box B =21960
Total VA 21960
First 8,000 VA @ 100%8000 Remaining VA @ 40%
Remaining VA =13960 13960 x 40% =5584 VA
Adding First 8000 VA 8000 VA
Total VA for Gen. Lights/Recep, Appliances & Dedicated circuits:13584 VA
Total AMP for Gen. Lights/Recep, Appliances & Dedicated circuits:56.60 Amps
Part #3 - Section 220.83 (B) Heating and A/C loads:
*Combine the larger loads of either the Heating or the A/C loads togther
100% of all the Heating or A/C loads in VA:4,704 VA
100% of all the Heating or A/C loads in Amps:19.60 A
VA Volts Amps
Parts #1 & #2 13584 240 56.60
Part #3 4,704 240 19.60
Total VA for all Parts:18,288
Totals Service/Feeder Load 76.20
#ESTAMP
Laundry
Appliance Circuit(s)
Dishwasher(s)
Disposal(s)
Dedicated circuit
House
Square Footage
2500
Article 220 - Service/Feeder calculation for (address):
2100 E Wellington Ave Santa Ana CA USA 92701
Building VA (watts)
7500
Amps
31.25
Job Code
109R-100LUMB
Totals from all Parts
Dedicated circuit
Total for Part #1:
Water Heater
Refrigerator(s)
Microwave(s)
Totals for Part #2:Pool Equipment
Dryer
Range
Oven
Cooktop
2100 E Wellington
Ave11/18/2024
Bus Rating:100
Main Rating:100
0%26%
Itemized House and 240V Loads for Panel: (VA)
5760
Not Fed by other panels
Feeds: Panel 2 61.35
14.85
76.20
Bus Rating:225
Main Rating:70
100%74%
Itemized House and 240V Loads for Panel: (VA)
1500 1500
1500 1000
600 1000
1600 4704
Fed by: Panel 1
61.35
61.35Total Load Calc:
Disposal
Load Calc: (This Panel)
Dryer
Load Calc: (This Panel)
Total Load Calc:
Panel 2 of 2
Refrigerator
Microwave A/C Unit - 240V
Laundry Appliance Circuit - 1
Appliance Circuit - 2 Dishwasher
Panel % of Sq.Ft:Panel % of 100% VA:
Panel 1 of 2
Panel % of Sq.Ft:Panel % of 100% VA:
2100 E Wellington
Ave11/18/2024
City of Santa Ana,
SIGNATURE:___________________ DATE:__________
717 17th Street, Ste. 200 | Denver, CO 80202
I, Efren Lumbreras, grant authorization to SUNRUN SOLAR to install Rooftop Mounted Solar
on my residence located at 2100 e wellington ave , SANTA ANA, CA, 92701.
Docusign Envelope ID: F5943A89-403A-416A-96D8-EDBA17FA2AE7
10/9/2024
2100 E Wellington
Ave11/18/2024
Certificate Of Completion
Envelope Id: F5943A89403A416A96D8EDBA17FA2AE7 Status: Completed
Subject: Complete asap for Sunrun project----Efren-- 109R-100LUMB----Solar Authorization Letter.pdf
Source Envelope:
Document Pages: 1 Signatures: 1 Envelope Originator:
Certificate Pages: 6 Initials: 0 Daniel Munoz
AutoNav: Enabled
EnvelopeId Stamping: Enabled
Time Zone: (UTC-08:00) Pacific Time (US & Canada)
225 Bush Street, Suite 1400
San Francisco, CA 94104
daniel.munoz@sunrun.com
IP Address: 73.111.240.71
Record Tracking
Status: Original
10/9/2024 10:45:10 AM
Holder: Daniel Munoz
daniel.munoz@sunrun.com
Location: DocuSign
Signer Events Signature Timestamp
Efren Lumbreras
elumber80@yahoo.com
Mr
Security Level: Email, Account Authentication
(None)Signature Adoption: Pre-selected Style
Using IP Address: 76.33.93.147
Signed using mobile
Sent: 10/9/2024 10:49:39 AM
Viewed: 10/9/2024 11:34:08 AM
Signed: 10/9/2024 11:34:41 AM
Electronic Record and Signature Disclosure:
Accepted: 10/9/2024 11:34:08 AM
ID: dd79485e-b117-4260-b7c5-cb7f476573a2
In Person Signer Events Signature Timestamp
Editor Delivery Events Status Timestamp
Agent Delivery Events Status Timestamp
Intermediary Delivery Events Status Timestamp
Certified Delivery Events Status Timestamp
Carbon Copy Events Status Timestamp
Ian Bunker
ian.bunker@sunrun.com
Mr.Ian Bunker
Security Level: Email, Account Authentication
(None)
Sent: 10/9/2024 10:49:39 AM
Viewed: 10/9/2024 11:11:06 AM
Electronic Record and Signature Disclosure:
Accepted: 10/8/2024 10:48:46 AM
ID: ed05bd1f-39f1-4346-a3f6-80438faef792
Witness Events Signature Timestamp
Notary Events Signature Timestamp
Envelope Summary Events Status Timestamps
Envelope Sent Hashed/Encrypted 10/9/2024 10:49:39 AM
Certified Delivered Security Checked 10/9/2024 11:34:08 AM
Signing Complete Security Checked 10/9/2024 11:34:41 AM
Completed Security Checked 10/9/2024 11:34:41 AM
2100 E Wellington
Ave11/18/2024
Payment Events Status Timestamps
Electronic Record and Signature Disclosure
2100 E Wellington
Ave11/18/2024
CONSUMER DISCLOSURE
From time to time, Sunrun Inc. (we, us or Company) may be required by law to provide to you
certain written notices or disclosures. Described below are the terms and conditions for providing
to you such notices and disclosures electronically through the DocuSign, Inc. (DocuSign)
electronic signing system. PLEASE READ THE INFORMATION BELOW CAREFULLY
AND THOROUGHLY, AND IF YOU CAN ACCESS THIS INFORMATION
ELECTRONICALLY TO YOUR SATISFACTION AND AGREE TO THESE TERMS AND
CONDITIONS, PLEASE CONFIRM YOUR AGREEMENT BY CLICKING THE 'I AGREE'
BUTTON AT THE BOTTOM OF THIS DOCUMENT.
Getting paper copies
At any time, you may request from us a paper copy of any record provided or made available
electronically to you by us. You will have the ability to download and print documents we send
to you through the DocuSign system during and immediately after signing session and, if you
elect to create a DocuSign signer account, you may access them for thirty (30) days after such
documents are first sent to you. After such time, if you wish for us to send you paper copies of
any such documents from our office to you, please request delivery of such paper copies from us
by following the procedure described below.
Withdrawing your consent
If you decide to receive notices and disclosures from us electronically, you may at any time
change your mind and tell us that thereafter you want to receive required notices and disclosures
only in paper format. How you must inform us of your decision to receive future notices and
disclosure in paper format and withdraw your consent to receive notices and disclosures
electronically is described below.
Consequences of changing your mind
If you elect to receive required notices and disclosures only in paper format, it will slow the
speed at which we can complete certain steps in transactions with you and delivering services to
you because we will need first to send the required notices or disclosures to you in paper format,
and then wait until we receive back from you your acknowledgment of your receipt of such
paper notices or disclosures. To indicate to us that you are changing your mind, you must
withdraw your consent using the DocuSign ‘Withdraw Consent’ form on the signing page of a
DocuSign envelope instead of signing it. This will indicate to us that you have withdrawn your
consent to receive required notices and disclosures electronically from us and you will no longer
be able to use the DocuSign system to receive required notices and consents electronically from
us or to sign electronically documents from us.
All notices and disclosures will be sent to you electronically
Unless you tell us otherwise in accordance with the procedures described herein, we will provide
electronically to you through the DocuSign system all required notices, disclosures,
authorizations, acknowledgements, and other documents that are required to be provided or made
available to you during the course of our relationship with you. To reduce the chance of you
inadvertently not receiving any notice or disclosure, we prefer to provide all of the required
notices and disclosures to you by the same method and to the same address that you have given
us. Thus, you can receive all the disclosures and notices electronically or in paper format through
the paper mail delivery system. If you do not agree with this process, please let us know as
described below. Please also see the paragraph immediately above that describes the
consequences of your electing not to receive delivery of the notices and disclosures
electronically from us.
Electronic Record and Signature Disclosure created on: 8/7/2013 10:17:58 AM
Parties agreed to: Efren Lumbreras, Ian Bunker 2100 E Wellington
Ave11/18/2024
How to contact Sunrun Inc.:
You may contact us to let us know of your changes as to how we may contact you electronically,
to request paper copies of certain information from us, and to withdraw your prior consent to
receive notices and disclosures electronically as follows:
To contact us by email send messages to: customercare@sunrun.com
You may also contact us in writing at 45 Fremont Street, 32nd Floor, San Francisco, CA 94105
or by phone at 1-855-478-6786.
To advise Sunrun Inc. of your new e-mail address
To let us know of a change in your e-mail address where we should send notices and disclosures
electronically to you, you must send an email message to us at customercare@sunrun.com and in
the body of such request you must state: your previous e-mail address, your new e-mail
address. We do not require any other information from you to change your email address.
In addition, you must notify DocuSign, Inc. at 1-866-219-4318 to arrange for your new email
address to be reflected in your DocuSign account by following the process for changing e-mail in
the DocuSign system.
To request paper copies from Sunrun Inc.
To request delivery from us of paper copies of the notices and disclosures previously provided
by us to you electronically, you must contact us by (a) sending us an e-mail to
customercare@sunrun.com, (b) writing to us at Sunrun Inc, 45 Fremont Street, 32nd Floor, San
Francisco, CA 94105, or (c) calling us at 1-855-478-6786, and in connection with your request
you must state your e-mail address, full name, US Postal address, and telephone number.
To withdraw your consent with Sunrun Inc.
To inform us that you no longer want to receive future notices and disclosures in electronic
format you may:
i. decline to sign a document from within your DocuSign session, and on the subsequent
page, select the check-box indicating you wish to withdraw your consent, or you may;
ii. contact us by (a) sending us an email to customercare@sunrun.com, (b) writing to us
at Sunrun Inc., 45 Fremont Street, 32nd Floor, San Francisco, CA 94105, or (c) calling us
at 1-855-478-6786, and in connection with your request you must state your e-mail, full
name, US Postal Address, and telephone number. We do not need any other information
from you to withdraw consent.. The consequences of your withdrawing consent for
online documents will be that transactions may take a longer time to process..
Required hardware and software
Operating
Systems: Windows® 2000, Windows® XP, Windows Vista®; Mac OS® X
2100 E Wellington
Ave11/18/2024
Browsers:
Final release versions of Internet Explorer® 6.0 or above (Windows only);
Mozilla Firefox 2.0 or above (Windows and Mac); Safari™ 3.0 or above
(Mac only)
PDF Reader: Acrobat® or similar software may be required to view and print PDF files
Screen
Resolution: 800 x 600 minimum
Enabled Security
Settings: Allow per session cookies
** These minimum requirements are subject to change. If these requirements change, you will be
asked to re-accept the disclosure. Pre-release (e.g. beta) versions of operating systems and
browsers are not supported.
Notices
Any notice or other communication to be made hereunder, even if otherwise required to be in
writing under other provisions of this Consent or any other documents or agreements that have
been provided to you in connection with this Consent, may alternatively be made in an electronic
record transmitted electronically to the electronic addresses provided by you. Any notice or other
communication made in electronic form will have the same legal effect and enforceability as if
made in non-electronic form.
Acknowledging your access and consent to receive materials electronically
To confirm to us that you can access this information electronically, which will be similar to
other electronic notices and disclosures that we will provide to you, please verify that you were
able to read this electronic disclosure and that you also were able to print on paper or
electronically save this page for your future reference and access or that you were able to e-mail
this disclosure and consent to an address where you will be able to print on paper or save it for
your future reference and access. Further, if you consent to receiving notices and disclosures
exclusively in electronic format on the terms and conditions described above, please let us know
by clicking the ‘I agree’ button below.
By checking the ‘I agree’ box, I confirm that:
I can access and read and have accessed, read and understood the terms of this
ELECTRONIC CONSENT TO ELECTRONIC RECEIPT OF ELECTRONIC
CONSUMER DISCLOSURES document; and
I can print on paper the disclosure or save or send the disclosure to a place where I can
print it, for future reference and access; and
Until or unless I notify Sunrun Inc. as described above, I consent to receive from
exclusively through electronic means all notices, disclosures, authorizations,
acknowledgements, and other documents that are required to be provided or made
available to me by Sunrun Inc. during the course of my relationship with you.
Entire Agreement Provision
This agreement and the consumer disclosure statement executed by the customer in conjunction
with and simultaneously with its review and acceptance of the terms set forth herein constitute
2100 E Wellington
Ave11/18/2024
the entire agreement between the parties with respect to the subject matter hereof and supersede
any prior understandings, agreements, or representations by or between the parties, written or
oral, to the extent they relate in any way to the subject matter hereof.
2100 E Wellington
Ave11/18/2024
2100 E Wellington
Ave11/18/2024
10/6/2024
RE: Structural Certification for Installation of Residential Solar
EFREN LUMBRERAS:2100 E WELLINGTON AVE, SANTA ANA, CA, 92701
Attn: To Whom It May Concern
Design Criteria
Code 2022 California Building Code (ASCE 7-16)
Risk category II Wind Load (component and Cladding)
Roof Dead Load Dr 10 psf V 96 mph
PV Dead Load DPV 3 psf Exposure B
Roof Live Load Lr 20 psf
Ground Snow S 0 psf
If you have any questions on the above, please do not hesitate to call.
Sincerely,
Eugene Munyanziza, P.E.
EV Engineering, LLC
projects@evengineersnet.com Signed 10/6/2024
http://www.evengineersnet.com
Exp: 06/30/2026
Structural evalution were done in accordance with applicable building codes and considering design criteria
below:
This Letter is for a structural evaluation of the existing structure at the address above. The purpose of our
review was to determine the adequacy of the existing structure to support the proposed installation of solar
panels as well as the attachment of solar panel to the existing framing.
After review, we concluded that the existing structure is adequate to support the proposed solar panel
installation. Gravity load increase did not exceed 5% and therefore, this install meets the prescriptive
compliance requirements of the applicable IEBC.
projects@evengineersnet.com
http://www.evengineersnet.com
2100 E Wellington
Ave11/18/2024
Wind (Uplift Check)
DCR check= 0.76 CONNECTION PASS
Vertical Load Resisting System Design
Gravity Load Check
Roof Dead Load
Roof Dead Load 10.0 psf
PV Dead Load 3.0 psf
Roof Live Load 20 psf
PV Roof Live Load 0 psf
Snow Load 0 psf
IEBC Check
Existing With PV
Roof Dead Load (D) 10.0 13.0 psf
Roof Live Load (Lr) 19.1 0.0 psf
Roof Snow Load (S) 0.0 0.0 psf
Cs= 1 0.88
Existing With PV
(D + Lr) = 23.3 14.4 psf
(D + S) = 8.7 11.3 psf
Maximum Gravity Load 23.3 14.4 psf
Load Increase (%)-38.0% OK
IBC Provision 2018
Siesmic Loads Check
Roof Dead Load 10 psf
% or Roof with Pv 8.4%
Dpv and Racking 3 psf
Average Total Dead Load 10.3 psf
Increase in Dead Load 1.3%OK
Limits of Scope of Work and Liability
*The requirements of Section 806.2 of the 2018 IEBC are met and the
structure is permitted to remain unaltered.
The Existing structure is assumed to have been designed and constructed following appropriate codes and
to have appropriate permits. The analysis was according to applicable building codes, professional
engineering and design experience, opinions and judgments. This evalution produced for this structure's
assessment is only for the proposed solar panel installation referenced in the stamped plan set and were
made according to generally recognized structural analysis standards and procedures. Prior to
commencement of work, the contractor shall verify the framing sizes, spacings, and spans. Contractor shall
also verify that there is framing damage or deficiencies. If observed, the EOR must be notified before
install.
The increase in seismic Dead weight as a result of the solar system is less than 10% of the existing structure
and therefore no further seismic analysis is required.
projects@evengineersnet.com
http://www.evengineersnet.com
2100 E Wellington
Ave11/18/2024
Rev: 8/29/19
SOL-01 CBC 2016
Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only
Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and
sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of
minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required.
Project Address:
Contractor Company Name:
Contractor License Number:
YES NO Are the following applicable to the proposed project?
1. Will the PV system layout provide the required three-foot wide clear access pathways
per Section 605.11 of the California Fire Code, and is this shown on the roof plan?
2. Will the PV system be installed on a roof having only one roofing layer with no
overlays?
3. Will the PV array be flush mounted to the existing roof so that the plane of the
modules (panels) are parallel to the plane of the roof?
4. Will the PV system weigh maximum 4 pounds per square feet or less?
5. Will the PV system be installed where the modules do not overhang any roof edges
(such as eaves, gabled ends, ridges and hips)?
6. Will the PV system be installed with a space of 2” minimum to 10” maximum between
the underside of modules and the surface of the roof?
7. Will the PV system be installed without using any ballast system or counter-weight
system?
8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet
and is this maximum horizontal spacing shown on the plans?
9. Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch
embedment into roof rafters (with pre-drilled holes) and is this minimum embedment
shown on the plans?
10. Are ALL the structural pages of the plans stamped and signed by a California
licensed professional engineer? (including project specific site plan, PV layout,
anchorage spacing, anchorage details and manufacturer’s PV support information.)
I certify under penalty of perjury under the laws of the State of California that the above is true:
Print Name: Signature:
Phone Number: Date:
Email Address:
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
RESIDENTIAL
PHOTOVOLTAIC
CHECKLIST
caitlyn hernandez
385-400-5019
oc_permits@sunrun.com
2100 E Wellington
Ave11/18/2024
PAGE
REV: F 6/2/2025
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
EFREN LUMBRERAS
2100 E WELLINGTON AVE,
SANTA ANA, CA, 92701
PROJECT NUMBER:
109R-100LUMB
SHEET
DESIGNER:
KEVIN SIN
CUSTOMER RESIDENCE:
TEL. (949) 763-0025
APN: 400-153-29
GILBERT CORREIA, C10, C46
CA CL #750184
(415) 580-6920 ex3
PV-2.1
INTERIOR GARAGE WALL
ACD
ESS ELEVATION VIEW - SCALE = NTS
ESS ELEVATION VIEW
ESS ELEVATION VIEW
PW3
ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS IN ACCORDANCE WITH R328.4.
ESS UNITS SHALL BE SEPARATED FROM EACH OTHER BY NOT LESS THAN 3 FEET EXCEPT
WHERE SMALLER SEPARATION DISTANCES ARE DOCUMENTED TO BE ADEQUATE BASED ON
LARGE/SCALE FIRE TESTING.
NO DWELLING DOORS OR WINDOWS ARE IN NEARBY
HEAT SENSOR
15'
3'MIN
A HEAT DETECTOR, LISTED AND INTERCONNECTED TO THE SMOKE
ALARMS, SHALL BE INSTALLED IN LOCATIONS WITHIN DWELLING UNITS
AND ATTACHED GARAGES WHERE SMOKE ALARMS CANNOT BE INSTALLED
BASED ON THEIR LISTING.
F
Signed: 06/03/2025
Revision to 20184282 issued on 11/18/2024
Rev 1 # 20185569
APPROVALS:
ELECT - M. Smith
PAGE
REV: F 6/2/2025
EFREN LUMBRERAS
2100 E WELLINGTON AVE,
SANTA ANA, CA, 92701
PROJECT NUMBER:
109R-100LUMB
SHEET
DESIGNER:
KEVIN SIN
CUSTOMER RESIDENCE:
TEL. (949) 763-0025
APN: 400-153-29
(415) 580-6920 ex3
Template_version_v5_2024.02.28
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
PL
PL
PL
PL
PLPL
PL
PL
PL
PL
PL PL
SITE PLAN
PV-2.0
#SSTAMPSP
#ESTAMPSP
NOTES:
·RESIDENCE DOES NOT CONTAIN ACTIVE FIRE
SPRINKLERS.
ARRAY DETAILS:
·TOTAL ROOF SURFACE AREA: 2500 SQFT.
·TOTAL PV ARRAY AREA: 210.2 SQ FT.
·PERCENTAGE PV COVERAGE:
(TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE
AREA) * 100 = 8.4%
ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS
IN ACCORDANCE WITH R328.4. ESS UNITS SHALL BE
SEPARATED FROM EACH OTHER BY NOT LESS THAN 3 FEET
EXCEPT WHERE SMALLER SEPARATION DISTANCES ARE
DOCUMENTED TO BE ADEQUATE BASED ON LARGE/SCALE
FIRE TESTING.
SITE PLAN - SCALE = 1/16" = 1'-0"
(E) RESIDENCE
(N) ARRAY AR-01
FIRE SETBACKS
(18" TYP)ROOF PATHWAYS
(3' TYP)
SE
MP
E WELLINGTON AVE
ROOF PATHWAYS
(3' TYP)
MD
AC
INV
(E) FENCE
(E) CHIMNEY
(E) GATE(TYP.)
A
AA
A
A
A
A
A
AA
GENERATION PANEL
RAIL
STANDOFFS &
FOOTINGS
SOLAR
MODULES
SOLAREDGE METER
AC DISCONNECT(S)
PM
SE
MP MAIN PANEL
SERVICE ENTRANCE
SCALE: NTS
NOTE: NOT ALL ITEMS IN LEGEND
WILL APPEAR IN SITE PLAN
LEGEND SM
INV INVERTER(S)
AC
DC DISCONNECT(S)DEDICATED PV METER DC
SUB-PANELSP
LC PV LOAD CENTER SEM BACKUP LOADS PANEL
BACKUP INTERFACE
MICROGRID
INTERCONNECT DEVICE
AM
ENERGY STORAGE
SYSTEM METER ADAPTER
MD
BP
MA
BIACREL METER
ELECTRIC VEHICLE
SUPPLY EQUPMENTEV
CB IQ COMBINER BOX
1 COMMUNICATION
WIRES
GROUNDING
ELECTRODE
BACKUP GATEWAY
GP
BG
POWERWALL ENERGY
STORAGE SYSTEM (ESS)
INTERIOR EQUIPMENT
SHOWN AS DASHED
EXTERNAL RAPID
SHUTDOWN SWITCHRSD
ARRAY
PITCH
PV AREA
(SQFT)
AR-01 18° 210.2
TRUE
AZIM
MAG
AZIM
259°271°
NOTE: ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE
INSTALLED PER NEC 690.12
ESS INTERIOR INSTALLATION WILL COMPLY WITH SMOKE AND HEAT
MONITORING REQUIREMENTS FOR 2022 CFC 1207.11.6
ESS INTERIOR INSTALLATION LOCATION WILL COMPLY WITH IMPACT
PROTECTION REQUIREMENTS FOR 2022 CFC 1207.11.7.3
RSD
F AC
Signed: 06/03/2025
PAGE
REV: F 6/2/2025
EFREN LUMBRERAS
2100 E WELLINGTON AVE,
SANTA ANA, CA, 92701
PROJECT NUMBER:
109R-100LUMB
SHEET
DESIGNER:
KEVIN SIN
CUSTOMER RESIDENCE:
TEL. (949) 763-0025
APN: 400-153-29
(415) 580-6920 ex3
Template_version_v5_2024.02.28
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
NEW 200A
MAIN BREAKER
END FED
NEW 200A
MAIN PANEL
225A BUS
60A
J-BOX
LONGI GREEN ENERGY
TECHNOLOGY CO LTD:
LR5-54HABB-400M
STRING 1 OF 10 MODULES
4 MODULE LEVEL
RAPID SHUTDOWN DEVICES
12
POINT OF INTERCONNECTION: 705.12(B)(3)(2), GATEWAY
BREAKER AT OPPOSITE END OF BUSBAR
METER
NUMBER: 222013-049004
EQUIPMENT CHARACTERISTICS
INCLUDED IN SPEC SHEETS
NOTE: TOTAL PV BACKFEED
= 60A USED FOR INTERCONNECTION CALCULATIONS(N) LOCKABLE
BLADE TYPE
AC DISCONNECT
SQUARE D
DU222RB
3R, 60A,2P
120/240VAC
3
FACILITY
GROUND
3
TESLA
POWERWALL 3 1707000-XX-Y
TESLA: POWERWALL
3 1707000-XX-Y
11500 WATT
INVERTER
LOAD RATED DC
DISCONNECT WITH
AFCI RAPID
SHUTDOWN
COMPLIANT
M
TESLA
BACKUP
SWITCH
(N) IMO PE69-3020,
DISCONNECT
SWITCH, 3P, 16A
RSD
(N) LOCKABLE
BLADE TYPE
AC DISCONNECT
SQUARE D
DU222RB
3R, 60A,2P
120/240VAC
3
CONDUIT SCHEDULE
TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT
1 Inverter Input (2) 10 AWG (PV WIRE)N/A 6 AWG (BARE) Open Air
2 Inverter Input (2) 10 AWG
THHN/THWN-2 N/A 8 AWG THHN/THWN-2 3/4 EMT
3 Inverter Output (2) 6 AWG
THHN/THWN-2
(1) 6 AWG
THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT
PV-4.0
ELECTRICAL
#ESTAMP
MODULE CHARACTERISTICS
LONGI GREEN ENERGY
TECHNOLOGY CO LTD:
LR5-54HABB-400M
400 W
OPEN CIRCUIT VOLTAGE 37.05 V
MAX POWER VOLTAGE 30.94 V
SHORT CIRCUIT CURRENT 14.88 A
INSTALLER MUST CHECK THE CONDITION, INSTALLABILITY AND CODE
COMPLIANCE OF EXISTING EQUIPMENT.
INSTALL THE BACKED UP LOAD CONDUCTORS AND THE GATEWAY BREAKER
CONDUCTORS IN TWO SEPARATE CONDUITS.
IF THE RELOCATED LOADS EXTEND MORE THAN 6 FEET, AFCI PROTECTION
APPLIES PER 2019 CEC 210.12
ANY MULTIWIRE BRANCH CIRCUITS RELOCATED ARE TO BE IDENTIFIED,
GROUPED, AND EQUIPPED WITH A 2-POLE OCPD BREAKER PER CEC 210.4(B,D)
A HEAT DETECTOR, LISTED AND INTERCONNECTED TO THE SMOKE ALARMS,
SHALL BE INSTALLED IN LOCATIONS WITHIN DWELLING UNITS AND ATTACHED
GARAGES WHERE SMOKE ALARMS CANNOT BE INSTALLED BASED ON THEIR
LISTING..
GENERAL NOTES:
• CITY REQUIRES TWO SOURCES OF GROUND - UFER, TWO GROUNDS RODS OR
COLD WATER GAS BOND
F
F
PAGE
REV: F 6/2/2025
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
EFREN LUMBRERAS
2100 E WELLINGTON AVE,
SANTA ANA, CA, 92701
PROJECT NUMBER:
109R-100LUMB
SHEET
DESIGNER:
KEVIN SIN
CUSTOMER RESIDENCE:
TEL. (949) 763-0025
APN: 400-153-29
GILBERT CORREIA, C10, C46
CA CL #750184
(415) 580-6920 ex3
PV-4.1
ELECTRICAL CALCS
Template_version_v5_2024.02.28
ELECTRICAL CALCS
SYSTEM INFORMATION
4 KW DC PHOTOVOLTAIC SYSTEM
(10) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-400M, TESLA: POWERWALL 3 1707000-XX-Y
ALLOWABLE BACKFEED ALLOWABLE BACKFEED = (MAIN PANEL RATING) X 1.2 - (MAIN BREAKER RATING) =
225A X 1.2 - 200A = 70A
60A ≤ 70A → INTERCONNECTION MEETS 705.12(B)(3)(2) REQUIREMENTS.
DC WIRE SIZING
MAX CIRCUIT CURRENT = (MODULE ISC) X (HIGH IRRADIANCE)[690.8(A)(1)] X (CONTINUOUS LOAD)[690.8(B)(1)]=
14.88A X 1.25 X 1.25= 23.25A
ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR
AMPACITY)[TABLE 310.16] =
0.91 X 1 X 40A = 36.4A
TERMINAL RATING[110.14(C)] =
10 AWG, RATED = 35A
35A < 36.4A → TERMINAL RATING GOVERNS CONDUCTOR SIZING.
23.25A < 35A → 10 AWG AMPACITY OK
THEREFORE 10 AWG IS SUFFICIENT.
AC WIRE SIZING
MAX AC OUTPUT CURRENT = (MAX INVERTER OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] =
48 A X 1.25 = 60 A
ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR
AMPACITY)[TABLE 310.16] =
0.91 X 1 X 75A = 68.25A
TERMINAL RATING[110.14(C)] =
6 AWG, RATED = 65A
65A < 68.25A → ADJUSTED CONDUCTOR AMPACITY GOVERNS CONDUCTOR SIZING.
60A < 65A → 6 AWG AMPACITY OK
THEREFORE 6 AWG IS SUFFICIENT.
SYSTEM CHARACTERISTICS
MAX OPEN CIRCUIT VOLTAGE = {[((TEMP COEF VOC) X (VOC)) / 100] X [LOW TEMP - STC TEMP] + VOC} X (# MODULES / STRING)
=
{[(-0.26 %/°C X 37.05 V) / 100] X [-2 °C - 25 °C] + 37.05 V} X 10 = 397 V
SHORT CIRCUIT CURRENT = 1.25 X (MODULE ISC) X (# STRINGS)
1.25 X 14.88 A X 1 = 18.6A
F
PV-4.3
#ESTAMP
PANEL
SCHEDULE
PAGE
REV: F 6/2/2025
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
EFREN LUMBRERAS
2100 E WELLINGTON AVE,
SANTA ANA, CA, 92701
PROJECT NUMBER:
109R-100LUMB
SHEET
DESIGNER:
KEVIN SIN
CUSTOMER RESIDENCE:
TEL. (949) 763-0025
APN: 400-153-29
GILBERT CORREIA, C10, C46
CA CL #750184
(415) 580-6920 ex3
50
20
200
60
ESS +PV
BREAKER
BEDROOM 1 LIGHTS
AIR CON
15
15
15
BATHROOM 1 OUTLETS
BATHROOM 1 LIGHTS
GARAGE LIGHTS
20
20
PANEL SCHEDULE
DISHWASHER
20
15
1520
KITCHEN LIGHTS
REFRIDGERATOR
30DRYER
20
20
20
20
LIVING OUTLETS
KITCHEN OUTLETS
LIVING LIGHTS BEDROOM 1 OUTLETS2020
BATHROOM 2 OUTLETS
BATHROOM 2 LIGHTS
BEDROOM 2 LIGHTS
BEDROOM 2 OUTLETS
GARAGE OUTLETS
FUTURE 225/200
MAIN PANEL
F
PAGE
REV: F 6/2/2025
EFREN LUMBRERAS
2100 E WELLINGTON AVE,
SANTA ANA, CA, 92701
PROJECT NUMBER:
109R-100LUMB
SHEET
DESIGNER:
KEVIN SIN
CUSTOMER RESIDENCE:
TEL. (949) 763-0025
APN: 400-153-29
(415) 580-6920 ex3
Template_version_v5_2024.02.28
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
SIGNAGE
PV-5.0
#ESTAMP
LABEL LOCATION:
ENERGY STORAGE SYSTEM DISCONNECT
PER CODE(S): NEC 2020: 706.15(C), CEC 2022: 706.15(C)
WARNING!
DO NOT RELOCATE THIS
OVERCURRENT DEVICE
LABEL LOCATION:
ADJACENT TO PV BREAKER AND ESS
OCPD (IF APPLICABLE).
PER CODE(S): NEC 2020: 705.12(B)(3)(2),
CEC 2022: 705.12(B)(3)(2)
NOTES AND SPECIFICATIONS:
·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2022 ARTICLE
110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR
IF REQUESTED BY THE LOCAL AHJ.
·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
WORDS, COLORS AND SYMBOLS.
·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING
METHOD AND SHALL NOT BE HAND WRITTEN.
·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
INVOLVED.
·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY
SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.
·DO NOT COVER EXISTING MANUFACTURER LABELS.
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
SOLAR ELECTRIC
PV PANELS
LABEL LOCATION:
ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE
DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
ARE CONNECTED.
PER CODE(S): NEC 2020: 690.56(C), CEC 2022: 690.56(C)
4"
3"
ELECTRICAL SHOCK HAZARD
WARNING
LABEL LOCATION:
INVERTER(S), AC/DC DISCONNECT(S),
AC COMBINER PANEL (IF APPLICABLE).
PER CODE(S): NEC 2020: 690.13(B), CEC
2022: 690.13(B)
!
INVERTER 1
PHOTOVOLTAIC DC DISCONNECT
MAXIMUM SYSTEM VOLTAGE:VDC550
LABEL LOCATION:
INVERTER(S), DC DISCONNECT(S).
PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53
LABEL LOCATION:
INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
AT EACH TURN, ABOVE AND BELOW PENETRATIONS,
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
PER CODE(S): NEC 2020: 690.31(D)(2), CEC 2022:
690.31(D)(2)
PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10
LABEL LOCATION:
INSTALLED WITHIN 3' OF RAPID SHUT DOWN
SWITCH PER CODE(S): NEC 2020: 690.56(C)(2),
CEC 2022: 690.56(C)(2), IFC 2018: 1204.5.3
WARNING!
SOURCES: UTILITY GRID,
BATTERY AND PV SOLAR
ELECTRIC SYSTEM
THREE POWER SUPPLY
LABEL LOCATION:
UTILITY SERVICE METER AND MAIN
SERVICE PANEL.
PER CODE(S): NEC 2020: 705.12(C), CEC
2022: 705.12(C)CAUTION:
2100 E WELLINGTON AVE, SANTA ANA, CA, 92701
SOLAR PANELS ON ROOF
MULTIPLE SOURCES OF POWER
LABEL LOCATION:
AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION.
PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54
PV SYSTEM DISCONNECT
RAPID SHUTDOWN SWITCH
SERVICE ENTRANCE AND TESLA
BACKUP SWITCH
INVERTER + BATTERY (INT)
AC DISCONNECT (INT)
F
AC DISCONNECT (EXT)