Loading...
HomeMy WebLinkAbout1506 1%2 W 7th St - PlanPAGE REV: C 6/2/2025 KEVIN COUGHLIN 1506 1/2 W 7TH STREET SANTA  ANA CA USA 92703 PROJECT NUMBER:   109R-506COUG SHEET DESIGNER: ARJUN RAMESH CUSTOMER RESIDENCE: TEL. (714) 471-2941 APN: 405-072-03 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 COVER SHEET SCOPE OF WORK GENERAL NOTES PV-1.0 VICINITY MAP #SSTAMPCS #ESTAMPCS ABBREVIATIONS A AMPERE AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT (E)EXISTING ESS ENERGY STORAGE SYSTEM MSP MAIN SERVICE PANEL (N)NEW PRE-FAB PRE-FABRICATED PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS V VOLTS W WATTS SHEET INDEX REV NAME DATE COMMENTS MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. CEC 2022. CEC 2022. INVERTER. SYSTEM COMPLIES WITH 690.41(A). ARRAY ARE LIMITED TO LESS THAN 30V IN 30 SECONDS AND CEC 2022 690.12(B)(2)(2) WHERE CONDUCTORS INSIDE  THE ARRAY BOUNDARY IS LIMITED TO LESS THAN 80V IN 30 SECONDS VOLTAGE IN ACCORDANCE WITH CEC 706.20 AND EXCEPTION 1 CEC 706.20 (B).  THROUGH A WALL OR PARTITION PER 706.15(D).  THAN 6FT AND DOES NOT INCLUDE ANY ADDITIONAL OUTLETS OR DEVICES PER CEC 210.12(D). BY THE SINGLE LARGEST UTILIZATION EQUIPMENT CONNECTED TO THE SYSTEM PER CEC ARTICLE 710.15(A) LTD: LR5-54HABB-400M (MCI-2) ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE 1707000-XX-Y WITH INTERGRATED INVERTER: 13.5 kWh PER  PW3 TOTAL ENERGY CAPACITY (IN kWh): 27.0kWH, (1) TESLA: POWERWALL 3 EXPANSION 1807000-XX-Y ULTRA RAIL, ATTACHMENT DETAIL, UMBRELLA L  FOOT TO FRAMING, SNR-DC-00339 TRENCHING REQUIRED: AC WIRE TO BE TRENCHED 10 FT  IN  CONCRETE MATERIAL. MATERIAL. INSTALLED, SEE PV-4.0 FOR INTERCONNECTION DETAILS 1506 W 7th St Santa  Ana CA USA 92703 PAGE # DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-2.1 EQUIPMENT  ELEVATION PV-3.0 LAYOUT PV-3.1 MOUNTING DETAIL PV-4.0 ELECTRICAL PV-4.1 ELECTRICAL CONT. PV-4.2 ELECTRICAL CALCS PV-4.3 BACKUP LOAD CALCS PV-4.4  PANEL SCHEDULE PV-5.0 SIGNAGE PV-5.1 SIGNAGE 2 C ***The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown.*** Bldg #101122883 & Elect #20185406 APPROVALS: ELECT - M. Smith /ce/ PAGE REV: C 6/2/2025 KEVIN COUGHLIN 1506 1/2 W 7TH STREET SANTA  ANA CA USA 92703 PROJECT NUMBER:   109R-506COUG SHEET DESIGNER: ARJUN RAMESH CUSTOMER RESIDENCE: TEL. (714) 471-2941 APN: 405-072-03 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 PL PL SITE PLAN PV-2.0 #SSTAMPSP #ESTAMPSP LC ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS IN ACCORDANCE  WITH R328.4. ESS UNITS SHALL BE SEPARATED FROM EACH OTHER BY NOT  LESS THAN 3 FEET EXCEPT WHERE SMALLER SEPARATION DISTANCES ARE  DOCUMENTED TO BE ADEQUATE BASED ON LARGE/SCALE FIRE TESTING. NOTE: ROOFTOP MODULE LEVEL RAPID  SHUTDOWN DEVICE INSTALLED PER CEC  690.12 ARRAY  PITCH PV AREA  (SQFT) AR-01 18° 84.1 AR-02 18° 147.17360° TRUE  AZIM MAG  AZIM 168°180° 348° DC DISCONNECT(S) AC DISCONNECT(S) SOLAREDGE METER SUNRUN METER DEDICATED PV METER SPAN-PANEL PV LOAD CENTER SM SERVICE ENTRANCE  MAIN PANEL SE MP PM SP LEGEND  SCALE: NTS NOTE: NOT ALL ITEMS IN LEGEND  WILL APPEAR IN SITE PLAN LC INVERTER(S) AC INV DC SEM INTERIOR EQUIPMENT  SHOWN AS DASHED POWERWALL ENERGY  STORAGE SYSTEM (ESS) COMMUNICATION  WIRES METER ADAPTER BACKUP INTERFACE MICROGRID  INTERCONNECT DEVICE BACKUP LOADS PANEL ELECTRIC VEHICLE  SUPPLY EQUPMENT MDEV IQ COMBINER BOX ENERGY STORAGE  SYSTEM BPCB MA BIACREL METERAM GROUNDING  ELECTRODE  1  GP GENERATION PANEL RAIL STANDOFFS &  FOOTINGS SOLAR  MODULESBACKUP GATEWAYBG EXTERNAL  RAPID SHUTDOWN  SWITCH RSD SITE PLAN - SCALE = 3/34" = 1'-0" (E) RESIDENCE (N) ARRAY AR-01 (N) ARRAY AR-02 (E) PV ARRAY FIRE SETBACKS (18" TYP) ROOF PATHWAYS (3' TYP) ROOF PATHWAYS (3' TYP) MP SE INV AC MD AC AC AC INV          A A B B B B (E) PV  EQUIPMENT PATIO TYPE (E) PV ARRAY PATIO (TYP) DETACHED STRUCTURE (TYP) (E) GATE (TYP) (E) RESIDENCE (E) FENCE NOTES:  RESIDENCE DOES NOT CONTAIN ACTIVE FIRE  SPRINKLERS. ARRAY DETAILS:  TOTAL ROOF SURFACE AREA: 1621 SQFT.  TOTAL PV ARRAY AREA (E+N): 437.67 SQ FT.  PERCENTAGE PV COVERAGE (E+N): (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE  AREA) * 100 = 27% (N) AC CONDUIT RUN (ENTRENCHED ~ 10 FT TRENCHING DEPTH TO BE 21'') W 7TH ST A A A AA SP 1/2 W 7TH ST (ADU FILED UNDER  SEPARATE PERMIT) W 7TH ST C C Exp. 12/31/2026Digitally Signed On: 06/02/25 /ce/ PAGE REV: C 6/2/2025 KEVIN COUGHLIN 1506 1/2 W 7TH STREET SANTA  ANA CA USA 92703 PROJECT NUMBER:   109R-506COUG SHEET DESIGNER: ARJUN RAMESH CUSTOMER RESIDENCE: TEL. (714) 471-2941 APN: 405-072-03 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 #SSTAMP DESIGN CRITERIA MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF WIND SPEED:  96 MPH 3-SEC GUST. FASTENERS: (1) 5/16" DIA S.S. UMBRELLA  SCREW: 2.5" MIN EMBEDMENT  INTO FRAMING PV-3.0 LAYOUT SOLAR MODULE SNAPNRACK  RACKING 4" MODULE ELEVATION DETAIL - SCALE: NTS ROOF INFO FRAMING INFO ATTACHMENT INFORMATION Name Type Height Type Max  Span OC  Spacing Detail Max Landscape  OC Spacing Max Landscape  Overhang Max Portrait  OC Spacing Max Portrait  Overhang Configuration AR-01 COMP SHINGLE - UR -  UMBRELLA L FOOT 1-Story 2X6 RAFTERS 9'-8" 16" ULTRA RAIL, ATTACHMENT DETAIL,  UMBRELLA L FOOT TO FRAMING,  SNR-DC-00339 5'-4"2'-1"5'-4"2'-1"STACKED AR-02 COMP SHINGLE - UR -  UMBRELLA L FOOT 1-Story 2X6 RAFTERS 9'-8" 16" ULTRA RAIL, ATTACHMENT DETAIL,  UMBRELLA L FOOT TO FRAMING,  SNR-DC-00339 5'-4" 2'-1" 5'-4" 2'-1" STACKED INSTALLERS SHALL NOTIFY ENGINEER OF ANY  POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO  PROCEEDING W/ INSTALLATION. D1 - AR-01 - SCALE: 1/8" = 1'-0" AZIM: 180° PITCH:18° D2 - AR-02 - SCALE: 1/8" = 1'-0" AZIM: 360° PITCH:18° * IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12"  BOUNDARY REGION OF ANY ROOF PLANE EDGES  (EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE  ADDED AND OVERHANG REDUCED WITHIN THE 12"  BOUNDARY REGION ONLY AS FOLLOWS: ** ALLOWABLE ATTACHMENT SPACING INDICATED ON  PLANS TO BE REDUCED BY 50%. ** ALLOWABLE OVERHANG INDICATED ON PLANS TO  BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING  INDICATED ON PLANS. 5'-4" TYP 11'-2" 5'-6" 18'-4" 3" 1'-4" 8'-1"6'-1" 5'-4" 5" 5'-4" TYP 15'-1" 5'-8" 2'2'-11" 8'-8"6'-7" 4'-4" 1' 5'-4" TYP. C Exp. 12/31/2026Digitally Signed On: 06/02/25 /ce/ PAGE REV: C 6/2/2025 KEVIN COUGHLIN 1506 1/2 W 7TH STREET SANTA  ANA CA USA 92703 PROJECT NUMBER:   109R-506COUG SHEET DESIGNER: ARJUN RAMESH CUSTOMER RESIDENCE: TEL. (714) 471-2941 APN: 405-072-03 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 UR-40 RAIL | UR-60 RAIL FOR USE WITH SNAPNRACK ULTRA SERIES RAILS PENETRATION DETAIL INSTALLED SECTION VIEW DESCRIPTION:DRAWING NUMBER:SCALE:DESIGNER: APPROVED BY: REVISION: Sunrun South LLC 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 ● FAX (415) 580-6902 THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. ULTRA RAIL, ATTACHMENT DETAIL, UMBRELLA L FOOT TO RAFTERSNR-DC-00339 1 5 7 2019 NEW DETAIL 1 6 18 2019 DRO-00138 B 6 22 2023 DC002707 REV: ADATE: DNS 02/09/2025  DRAFTER:    M.AFFENTRANGER E.FERGUSON M.AFFENTRANGER Solar Mounting Solutions MJA MJA MJA BIN: 8 214" 112" 112" 15 8" SNAPNRACK ULTRA RAIL UMBRELLA L FOOT WITH UMBRELLA FLASHING FOR COMPOSTION ROOF MOUNTING REFER TO SNAPNRACK ENGINEERING CHARTS FOR APPLICABLE RAIL SPANS. "BIN" NUMBER ON CHART SHOULD MATCH "BIN" NUMBER ON THIS DRAWING 516"Ø S.S. UMBRELLA LAG SCREW MUST EMBED A MIN. OF 212" INTO STRUCTURAL MEMBER TO UTILIZE STANDARD SNAPNRACK ENGINEERING. REACH OUT TO SNAPNRACK IF THIS IS NOT POSSIBLE REFER TO SNAPNRACK INSTALLATION MANUAL FOR516"Ø HARDWARE TORQUE SPECIFICATIONS RAIL CAN BE MOUNTED ON EITHER SIDE OF THE L-FOOT FOR LEVELING DETAILS, REFER TO SNAPNRACK DETAIL DRAWING "SNR-DC-00447" STRUCUTRAL MEMBER, WOOD RAFTER, TYP. ROOF DECKING, TYP. SNAPNRACK5 16"n UMBRELLA LAG SCREW, S.S. COMP SHINGLE ROOFING, TYP. SNAPNRACK ULTRA RAIL SNAPNRACK UMBRELLA FLASHING 212" MIN. EMBEDMENT INTO WOOD MEMBER MODULE HEIGHT OFF ROOF: UR-40: 338" - 438" UR-60: 4" - 5" SNAPNRACK ULTRA RAIL UMBRELLA L FOOT STRUCUTRAL MEMBER, WOOD RAFTER, TYP. ROOF DECKING, TYP. COMP SHINGLE ROOFING, TYP. SNAPNRACK ULTRA RAIL UMBRELLA L FOOT WITH UMBRELLA LAG AND FLASHING SNAPNRACK UMBRELLA FLASHING PV-3.1 MOUNTING DETAIL C Exp. 12/31/2026Digitally Signed On: 06/02/25 PAGE REV: C 6/2/2025 KEVIN COUGHLIN 1506 1/2 W 7TH STREET SANTA  ANA CA USA 92703 PROJECT NUMBER:   109R-506COUG SHEET DESIGNER: ARJUN RAMESH CUSTOMER RESIDENCE: TEL. (714) 471-2941 APN: 405-072-03 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 FACILITY  GROUND 120/240 VAC SINGLE PHASE SERVICE EXISTING 200A MAIN BREAKER -END FED EXISTING 200A MAIN PANEL 200A  BUS M TESLA  BACKUP  SWITCH 60A UL 9540  FACTORY WIRING  ASSEMBLY (1 ) TESLA POWERWALL 3 EXPANSION PACK 1807000-XX-Y TESLA POWERWALL 3 1707000-XX-Y POWERWALL 3 1707000-XX-Y 11500 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT, POWER CONTROL SYSTEM 3 J-BOX LONGI GREEN ENERGY TECHNOLOGY CO LTD LR5-54HABB-400M STRING 1 OF 4 MODULES 2  MODULE LEVEL RAPID SHUTDOWN DEVICES LONGI GREEN ENERGY TECHNOLOGY CO LTD LR5-54HABB-400M STRING 2 OF 7 MODULES 3  MODULE LEVEL RAPID SHUTDOWN DEVICES 1 1 2 POINT OF INTERCONNECTION: CEC 2022 705.13, LOAD J-BOX 14 Hanwha Q CELLS: Q.PEAK DUO-G7 320 EEExisting SolarEdge Technologies: SE3800H-USE Existing Inverter(s)AC DISCONNECT  30A E (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A , 2P 120/240VAC 3 (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A , 2P 120/240VAC 3T (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A , 2P 120/240VAC 3 (N)125A LOAD CENTER (E) 20A PV BREAKER (N) (1) 60A PV+ESS BREAKER 4 E 80A 20A OCPD E (N) TESLA REMOTE METER  SOALR PV CURRENT  TRANSFORMERS PV-4.0 ELECTRICAL #ESTAMP MODULE CHARACTERISTICS LONGI GREEN ENERGY  TECHNOLOGY CO LTD:  LR5-54HABB-400M 400 W OPEN CIRCUIT VOLTAGE 37.05 V MAX POWER VOLTAGE 30.94 V SHORT CIRCUIT CURRENT 14.88 A C Installed at ADU 1506-1/2 W 7th--MAS(19) There are no backup loads in this project. MAS(19) The PV system EGC/GEC must be bonded to the ADU subpanelEGCbus. The neutral bus remains isolated. MAS(19) PAGE REV: C 6/2/2025 KEVIN COUGHLIN 1506 1/2 W 7TH STREET SANTA  ANA CA USA 92703 PROJECT NUMBER:   109R-506COUG SHEET DESIGNER: ARJUN RAMESH CUSTOMER RESIDENCE: TEL. (714) 471-2941 APN: 405-072-03 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 CONDUIT SCHEDULE TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT 1 Inverter Input (2) 10 AWG  (PV WIRE)N/A 6 AWG (BARE)Open Air 2 Inverter Input (4) 10 AWG  THHN/THWN-2 N/A 8 AWG THHN/THWN-2 3/4 EMT 3 Inverter Output (2) 6 AWG  THHN/THWN-2 (1) 6 AWG  THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT 3T Trenched Conduit (2) 6 AWG  THHN/THWN-2 (1) 6 AWG  THHN/THWN-2 8 AWG THHN/THWN-2 1" SCH 40  PVC 4 Load Center Output (2) 4 AWG  THHN/THWN-2 (1) 4 AWG  THHN/THWN-2 8 AWG THHN/THWN-2 1 EMT E Existing #ESTAMP POWER CONTROL SYSTEM (PCS): SOURCES OF SUPPLY DOES NOT EXCEED THE RATING OF ANY BUSBAR OR CONDUCTOR  SUPPLIED BY THE POWER PRODUCTION SOURCES MONITORED BY THE PCS SHALL COMPLY WITH ARTICLE 705.12. WITH 240.6(C).  SETPOINTS:           - 160A - MAXIMUM TOTAL CURRENT ON THE CONTROLLED PANEL           - 0A - FAIL SAFE GENERATION BACKFEED CURRENT SUPPLY (120% COMPLIANT) PV-4.1 ELECTRICAL CONT. IF THE RELOCATED LOADS EXTEND MORE THAN 6 FEET, AFCI PROTECTION APPLIES PER  2019 CEC 210.12 CITY REQUIRES TWO SOURCES OF GROUND - UFER, TWO GROUNDS RODS OR COLD  WATER GAS BOND ANY MULTIWIRE BRANCH CIRCUITS RELOCATED ARE TO BE IDENTIFIED, GROUPED, AND  EQUIPPED WITH A 2-POLE OCPD BREAKER  PER CEC 210.4(B,D). C PAGE REV: C 6/2/2025 KEVIN COUGHLIN 1506 1/2 W 7TH STREET SANTA  ANA CA USA 92703 PROJECT NUMBER:   109R-506COUG SHEET DESIGNER: ARJUN RAMESH CUSTOMER RESIDENCE: TEL. (714) 471-2941 APN: 405-072-03 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 Inverter Calculations Each Inverter has the following values which are calculated following these formulas: Inverter X: {[((Temp Coef Voc) x (Voc)) / 100] x (Low Temp - STC Temp) + Voc} * (# Modules / String) Inverter Powerwall 3 1707000-xx-y Inverter Overcurrent Protection:    (Inverter(s) Max Combined Current) x (Continous Load) =     48A x 1.25+20 = 80A   80A Overcurrent Protection USING PCS Wire ampacity calculated from 310.15(B)(16) & (17) as appropriate with ambient temperature calculations from  310.15(B)(3)(c) and raceway fill adjustments from 310.15(B)(3)(a). Conduit on the roof shall be installed no less than 1" above  the roof deck. PV Circuit conductor ampacity is constrained using the 75°C column with the continuous duty uprating or the  90°C column with the relevant ambient temperature and raceway fill adjustments without the continuous duty uprating per  690.8(B), whichever results with a larger wire size. Non-PV Circuit Conductors use the ampacity in the 75°C column or the  90°C column with the relevant ambient temperature and raceway fill adjustments, whichever is less (110.14(C) &  310.15(A)(2)). The rating of the conductor after adjustments shall be greater than, or equal to, the continuous duty uprated  current.  Calc Ex: Wire Ampacity x Ambient Temp. Corr. Factor x Conduit Fill Adj. Factor >= Output Current PV-4.2 ELECTRICAL CALCS  ALLOWABLE BACKFEED  MAX ALLOWED TOTAL GENERATION BACKFEED OCPD = MAIN BREAKER RATING =  200A  80A ≤ 200A→ INTERCONNECTION MEETS CEC 2022 705.13 REQUIREMENTS. C PAGE REV: C 6/2/2025 KEVIN COUGHLIN 1506 1/2 W 7TH STREET SANTA  ANA CA USA 92703 PROJECT NUMBER:   109R-506COUG SHEET DESIGNER: ARJUN RAMESH CUSTOMER RESIDENCE: TEL. (714) 471-2941 APN: 405-072-03 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 BACKUP LOADS LOAD BREAKER RATING  (AMPS)LABEL 1 20A-1P BEDROOM LIGHTS 2 20A-1P BEDROOM OUTELTS 3 20A-1P KIT APPLIANCE 4 20A-1P OUTDOOR LIGHTS 5 20A-1P FRIDGE 6 20A-1P KITCHEN OUTLETS 7 20A-1P KITCHEN LIGHTS 8 20A-1P BATHROOM LIGHTS 9 20A-1P BATHROOM OUTLETS 10 50A-2P A/C UNIT 11 60A-2P ADU SUB PANEL SUB PANEL LOADS 1 20A-1P ADU BATH OUT 2 20A-1P ADU FRIDGE 3 15A-1P ADU BATH LIGHTS 4 20A-1P ADU BED 1 OUTLET 5 20A-1P ADU BED 2 OUTLET 6 20A-1P ADU BED 1 LIGHTS 7 20A-1P ADU BED 2 LIGHTS 8 20A-1P ADU GARAGE 9 20A-1P ADU APPLIANCE 1 10 20A-1P ADU APPLIANCE 2 11 20A-1P FAU 12 15A-1P ADU KITCHEN LIGHTS 13 15A-1P ADU KITCHEN OUTLET PV-4.3 BACKUP LOAD  CALCS C PAGE REV: C 6/2/2025 KEVIN COUGHLIN 1506 1/2 W 7TH STREET SANTA  ANA CA USA 92703 PROJECT NUMBER:   109R-506COUG SHEET DESIGNER: ARJUN RAMESH CUSTOMER RESIDENCE: TEL. (714) 471-2941 APN: 405-072-03 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 PV-4.4 60 NEW 125A LOAD  CENTER (N) PV + ESS   BREAKER  EXSITING 200/200  MAIN PANEL MAIN BREAKER 20 (E) PV  BREAKER 20 0 20 20 20 20 60 20 20 20 20 20 50 20 BATHROOM OUTLETS BATHROOM LIGHTS KITCHEN OUTLETS ADU SUB PANEL FRIDGE BEDROOM OUTLETS KIT APPLIANCE OUTDOOR LIGHTS BEDROOM LIGHTS A/C UNIT (N)TESLA  REMOTE  METER PANEL SCHEDULE  FUTURE 200/200  MAIN PANEL 80 LOAD CENTER  FEEDER BREAKER MAIN BREAKER 20 0 60 20 20 20 20 20 50 20 20 20 20KITCHEN LIGHTS BATHROOM OUTLETS BATHROOM LIGHTS KITCHEN OUTLETS ADU SUB PANEL FRIDGE BEDROOM OUTLETS KIT APPLIANCE OUTDOOR LIGHTS BEDROOM LIGHTS A/C UNIT KITCHEN LIGHTS 20 20 20 20 20 2020 20 20 20 1 5 15 15 60 ADU BED 2 LIGHTS ADU BED 2 OUTLETS ADU KIT LIGHTS ADU KIT OUTLET ADU BATH LIGHTS FAU ADU FRIDGE ADU BED 1 OUTLET ADU BED 1 LIGHTS ADU BATH OUT ADU GARAGE ADU APPLIANCE 1 ADU APPLIANCE 2 EXISTING 100A  SUB-PANEL C PAGE REV: C 6/2/2025 KEVIN COUGHLIN 1506 1/2 W 7TH STREET SANTA  ANA CA USA 92703 PROJECT NUMBER:   109R-506COUG SHEET DESIGNER: ARJUN RAMESH CUSTOMER RESIDENCE: TEL. (714) 471-2941 APN: 405-072-03 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 SIGNAGE PV-5.0 #ESTAMP NOMINAL ESS VOLTAGE VAC LABEL LOCATION: ENERGY STORAGE SYSTEM PER CODE(S): NEC 706.15(C), CEC 706.15(C) 120 240 520 VDCMAXIMUM ESS DC VOLTAGE:60 ENERGY STORAGE SYSTEM DISCONNECT ENERGY STORAGE SYSTEM PREMISES WIRING MAY REMAIN  ENERGIZED AFTER LOSS OF  UTILITY POWER CAUTION! LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2022: 706.15(C), NEC 2020: 706.15(C) WARNING! DO NOT RELOCATE THIS  OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS  OCPD (IF APPLICABLE). PER CODE(S): NEC 2020: 705.12(B)(3)(2),  CEC 2022: 705.12(B)(3)(2) NOTES AND SPECIFICATIONS:   SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE  CEC 2022 ARTICLE 110.21(B), UNLESS SPECIFIC  INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF  REQUESTED BY THE LOCAL AHJ.  SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS  USING EFFECTIVE WORDS, COLORS AND SYMBOLS.  LABELS SHALL BE PERMANENTLY AFFIXED TO THE  EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND  WRITTEN.  LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND  THE ENVIRONMENT INVOLVED.  SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,  PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE  SPECIFIED.  DO NOT COVER EXISTING MANUFACTURER LABELS. SOLAR PV SYSTEM EQUIPPED  WITH RAPID SHUTDOWN SOLAR ELECTRIC  PV PANELS TURN RAPID SHUTDOWN  SWITCH TO THE "OFF"  POSITION TO SHUT DOWN  PV SYSTEM AND REDUCE  SHOCK HAZARD IN THE  ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE  DISCONNECTING MEANS TO WHICH THE PV SYSTEMS  ARE CONNECTED. PER CODE(S): NEC 2020: 690.56(C), CEC 2022: 690.56(C) 4" 3" ELECTRICAL SHOCK HAZARD WARNING TERMINALS ON LINE AND LOAD  SIDES MAY BE ENERGIZED IN  THE OPEN POSITION LABEL LOCATION: INVERTER(S),  AC/DC DISCONNECT(S),  AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020: 690.13(B), CEC  2022: 690.13(B) ! INVERTER 1 PHOTOVOLTAIC DC DISCONNECT MAXIMUM SYSTEM VOLTAGE:VDC550 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53 WARNING: PHOTOVOLTAIC  POWER SOURCE WARNING: PHOTOVOLTAIC  POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,  AT EACH TURN, ABOVE AND BELOW  PENETRATIONS,  ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2020: 690.31(D)(2), CEC 2022:  690.31(D)(2) LABEL LOCATION: INSTALLED WITHIN 3' OF RAPID SHUT DOWN  SWITCH PER CODE(S): NEC 2020: 690.56(C)(2),  CEC 2022: 690.56(C)(2), IFC 2018: 1204.5.3 RAPID SHUTDOWN SWITCH  FOR SOLAR PV SYSTEM WARNING! SOURCES: UTILITY GRID,  BATTERY AND PV SOLAR  ELECTRIC SYSTEM THREE POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN  SERVICE PANEL. PER CODE(S): NEC 2020: 705.12(C), CEC  2022: 705.12(C) LABEL LOCATION: BACKUP LOAD PANEL (MAIN PANEL) NO ADDITIONAL  LOADS TO BE  ADDED MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE:           48 AMPS   240     VAC LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF  INTERCONNECTION. PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54 PV SYSTEM DISCONNECT THIS EQUIPMENT FED BY  MULTIPLE SOURCES. TOTAL  RATING OF ALL OVERCURRENT  DEVICES EXCLUDING MAIN  SUPPLY OVERCURRENT DEVICE  SHALL NOT EXCEED AMPACITY OF  BUSBAR WARNING! LABEL LOCATION: PV LOAD CENTER (IF APPLICABLE) AND  ANY PANEL THAT UTILIZES "THE SUM  OF BREAKERS RULE". PER CODE(S): NEC 2020: 705.12 (B)(3)(3),  CEC 2022: 705.12 (B)(3)(3) WARNING: THIS SENSOR IS PART  OF A POWER CONTROL SYSTEM.  DO NOT REMOVE. REPLACE ONLY  WITH THE SAME TYPE AND RATING. WARNING: THIS SENSOR IS PART  OF A POWER CONTROL SYSTEM.  DO NOT REMOVE. REPLACE ONLY  WITH THE SAME TYPE AND RATING. REQUIREMENT: UL 1741, SECTION 206.3 LOCATION: AROUND THE CT WIRE  BY CLAMP SIZE 4.25" X 0.75" INVERTER 1 LABEL LOCATION: REQUIREMENT: UL 1741, SECTION 206.1 AND 206.4 LOCATION: MAIN PANEL SIZE: 4.25" X 1.25" PCS CONTROLLED CURRENT SETTING:  160A   THE MAXIMUM OUTPUT CURRENT FROM THIS SYSTEM IS CONTROLLED ELECTRONICALLY. REFER TO THE MANUFACTURER'S INSTRUCTIONS FOR MORE INFORMATION. C PAGE REV: C 6/2/2025 KEVIN COUGHLIN 1506 1/2 W 7TH STREET SANTA  ANA CA USA 92703 PROJECT NUMBER:   109R-506COUG SHEET DESIGNER: ARJUN RAMESH CUSTOMER RESIDENCE: TEL. (714) 471-2941 APN: 405-072-03 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 PL PL PL PL SIGNAGE 2 PV-5.1 #ESTAMP CAUTION: 1506 1/2 W 7th Street Santa Ana CA USA 92703 SERVICE ENTRANCE AND  LOAD CENTER DISCONNECT PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10 MULTIPLE SOURCES OF POWER ESS DISCONNECT SYSTEM SHUTDOWN  DISCONNECT LABELING FORMAT LABELS SHALL BE RED PLASTIC MATERIAL WITH ENGRAVED WHITE LETTERS  MADE OF DURABLE ADHESIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR  THE ENVIRONMENT. LETTERS SHALL BE MINIMUM 3/8" IN SIZE. C Kevin coughlin 1506 w 7th st 717 17th Street,Ste.200 |Denver,CO 80202 Docusign Envelope ID:0FF7DD40-6DD1-48DB-AF2A-759275B9ABA1 2/25/2025 Certificate Of Completion Envelope Id: 0FF7DD40-6DD1-48DB-AF2A-759275B9ABA1 Status: Completed Subject: Complete with Docusign: uploaded-2025_02_24T21_37_16Z-Solar Authorization Letter.pdf Source Envelope: Document Pages: 1 Signatures: 1 Envelope Originator: Certificate Pages: 5 Initials: 0 Jamie Elgin AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) 225 Bush Street, Suite 1400 San Francisco, CA 94104 jamie.elgin@sunrun.com IP Address: 75.140.107.2 Record Tracking Status: Original 2/25/2025 8:02:26 AM Holder: Jamie Elgin jamie.elgin@sunrun.com Location: DocuSign Signer Events Signature Timestamp Kevin Coughlin kmecoughlin@gmail.com Security Level: Email, Account Authentication (None) Signature Adoption: Pre-selected Style Using IP Address: 99.9.137.112 Signed using mobile Sent: 2/25/2025 8:03:03 AM Viewed: 2/25/2025 11:35:42 AM Signed: 2/25/2025 11:35:49 AM Electronic Record and Signature Disclosure: Accepted: 2/25/2025 11:35:42 AM ID: 66db4456-bf6e-41a8-a21a-debb58a85300 In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 2/25/2025 8:03:03 AM Certified Delivered Security Checked 2/25/2025 11:35:42 AM Signing Complete Security Checked 2/25/2025 11:35:49 AM Completed Security Checked 2/25/2025 11:35:49 AM Payment Events Status Timestamps Electronic Record and Signature Disclosure CONSUMER DISCLOSURE From time to time, Sunrun Inc. (we, us or Company) may be required by law to provide to you certain written notices or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures electronically through the DocuSign, Inc. (DocuSign) electronic signing system. PLEASE READ THE INFORMATION BELOW CAREFULLY AND THOROUGHLY, AND IF YOU CAN ACCESS THIS INFORMATION ELECTRONICALLY TO YOUR SATISFACTION AND AGREE TO THESE TERMS AND CONDITIONS, PLEASE CONFIRM YOUR AGREEMENT BY CLICKING THE 'I AGREE' BUTTON AT THE BOTTOM OF THIS DOCUMENT. Getting paper copies At any time, you may request from us a paper copy of any record provided or made available electronically to you by us. You will have the ability to download and print documents we send to you through the DocuSign system during and immediately after signing session and, if you elect to create a DocuSign signer account, you may access them for thirty (30) days after such documents are first sent to you. After such time, if you wish for us to send you paper copies of any such documents from our office to you, please request delivery of such paper copies from us by following the procedure described below. Withdrawing your consent If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and disclosures electronically is described below. Consequences of changing your mind If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can complete certain steps in transactions with you and delivering services to you because we will need first to send the required notices or disclosures to you in paper format, and then wait until we receive back from you your acknowledgment of your receipt of such paper notices or disclosures. To indicate to us that you are changing your mind, you must withdraw your consent using the DocuSign ‘Withdraw Consent’ form on the signing page of a DocuSign envelope instead of signing it. This will indicate to us that you have withdrawn your consent to receive required notices and disclosures electronically from us and you will no longer be able to use the DocuSign system to receive required notices and consents electronically from us or to sign electronically documents from us. All notices and disclosures will be sent to you electronically Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you through the DocuSign system all required notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the disclosures and notices electronically or in paper format through the paper mail delivery system. If you do not agree with this process, please let us know as described below. Please also see the paragraph immediately above that describes the consequences of your electing not to receive delivery of the notices and disclosures electronically from us. Electronic Record and Signature Disclosure created on: 8/7/2013 10:17:58 AM Parties agreed to: Kevin Coughlin How to contact Sunrun Inc.: You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as follows: To contact us by email send messages to: customercare@sunrun.com You may also contact us in writing at 45 Fremont Street, 32nd Floor, San Francisco, CA 94105 or by phone at 1-855-478-6786. To advise Sunrun Inc. of your new e-mail address To let us know of a change in your e-mail address where we should send notices and disclosures electronically to you, you must send an email message to us at customercare@sunrun.com and in the body of such request you must state: your previous e-mail address, your new e-mail address. We do not require any other information from you to change your email address. In addition, you must notify DocuSign, Inc. at 1-866-219-4318 to arrange for your new email address to be reflected in your DocuSign account by following the process for changing e-mail in the DocuSign system. To request paper copies from Sunrun Inc. To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically, you must contact us by (a) sending us an e-mail to customercare@sunrun.com, (b) writing to us at Sunrun Inc, 45 Fremont Street, 32nd Floor, San Francisco, CA 94105, or (c) calling us at 1-855-478-6786, and in connection with your request you must state your e-mail address, full name, US Postal address, and telephone number. To withdraw your consent with Sunrun Inc. To inform us that you no longer want to receive future notices and disclosures in electronic format you may: i. decline to sign a document from within your DocuSign session, and on the subsequent page, select the check-box indicating you wish to withdraw your consent, or you may; ii. contact us by (a) sending us an email to customercare@sunrun.com, (b) writing to us at Sunrun Inc., 45 Fremont Street, 32nd Floor, San Francisco, CA 94105, or (c) calling us at 1-855-478-6786, and in connection with your request you must state your e-mail, full name, US Postal Address, and telephone number. We do not need any other information from you to withdraw consent.. The consequences of your withdrawing consent for online documents will be that transactions may take a longer time to process.. Required hardware and software Operating Systems: Windows® 2000, Windows® XP, Windows Vista®; Mac OS® X Browsers: Final release versions of Internet Explorer® 6.0 or above (Windows only); Mozilla Firefox 2.0 or above (Windows and Mac); Safari™ 3.0 or above (Mac only) PDF Reader: Acrobat® or similar software may be required to view and print PDF files Screen Resolution: 800 x 600 minimum Enabled Security Settings: Allow per session cookies ** These minimum requirements are subject to change. If these requirements change, you will be asked to re-accept the disclosure. Pre-release (e.g. beta) versions of operating systems and browsers are not supported. Notices Any notice or other communication to be made hereunder, even if otherwise required to be in writing under other provisions of this Consent or any other documents or agreements that have been provided to you in connection with this Consent, may alternatively be made in an electronic record transmitted electronically to the electronic addresses provided by you. Any notice or other communication made in electronic form will have the same legal effect and enforceability as if made in non-electronic form. Acknowledging your access and consent to receive materials electronically To confirm to us that you can access this information electronically, which will be similar to other electronic notices and disclosures that we will provide to you, please verify that you were able to read this electronic disclosure and that you also were able to print on paper or electronically save this page for your future reference and access or that you were able to e-mail this disclosure and consent to an address where you will be able to print on paper or save it for your future reference and access. Further, if you consent to receiving notices and disclosures exclusively in electronic format on the terms and conditions described above, please let us know by clicking the ‘I agree’ button below. By checking the ‘I agree’ box, I confirm that:  I can access and read and have accessed, read and understood the terms of this ELECTRONIC CONSENT TO ELECTRONIC RECEIPT OF ELECTRONIC CONSUMER DISCLOSURES document; and  I can print on paper the disclosure or save or send the disclosure to a place where I can print it, for future reference and access; and  Until or unless I notify Sunrun Inc. as described above, I consent to receive from exclusively through electronic means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to me by Sunrun Inc. during the course of my relationship with you. Entire Agreement Provision This agreement and the consumer disclosure statement executed by the customer in conjunction with and simultaneously with its review and acceptance of the terms set forth herein constitute the entire agreement between the parties with respect to the subject matter hereof and supersede any prior understandings, agreements, or representations by or between the parties, written or oral, to the extent they relate in any way to the subject matter hereof. Section 220.82 Dwelling Unit Part #1 - Section 220.82 (B)(1) General Lighting/Receptacles @ 3 VA per sq ft: Amps Box A (VA) 20.26 4863 Part #2 - Section 220.82 Size in VA Size in VA 1500 N/A 3000 N/A 1000 N/A 600 N/A 1000 N/A 1600 N/A N/A N/A N/A N/A N/A N/A N/A Amps Box B (VA) N/A 36.25 8700 Total VA from Parts #1 and #2 combined:Box A + Box B =13563 Total VA 13563 First 10,000 VA @ 100%10000 Remaining VA @ 40% Remaining VA =3563 3563 x 40% =1425.2 VA Adding First 10,000 VA 10000 VA Total VA for Gen. Lights/Recep, Appliances & Dedicated circuits:11425.2 VA Total AMP for Gen. Lights/Recep, Appliances & Dedicated circuits:47.61 Amps Part #3 - Section 220.82 (C) Heating and A/C loads: *Combine the larger loads of either the Heating or the A/C loads togther 100% of all the Heating or A/C loads in VA:9,600 VA 100% of all the Heating or A/C loads in Amps:40.00 A VA Volts Amps Parts #1 & #2 11425.2 240 47.61 Part #3 9,600 240 40.00 Total VA for all Parts:21,025 Totals Service/Feeder Load 87.61 #ESTAMP Laundry Appliance Circuit(s) Dishwasher(s) Disposal(s) Dedicated circuit House Square Footage 1621 Article 220 - Service/Feeder calculation for (address): 1506 W 7th St Santa Ana CA USA 92703 Building VA (watts) 4863 Amps 20.2625 Job Code 109R-506COUG Totals from all Parts Dedicated circuit Total for Part #1: OTHER Water Heater Refrigerator(s) Microwave(s) Totals for Part #2:Pool Equipment Dryer Range Oven Cooktop Bus Rating:200 Main Rating:200 41%37% Itemized House and 240V Loads for Panel: (VA) 1500 1500 9600 Not Fed by other panels Feeds: Panel 2 30.09 57.51 87.61 Bus Rating:100 Main Rating:60 59%63% Itemized House and 240V Loads for Panel: (VA) 1500 1000 600 1000 1600 Fed by: Panel 1 30.09 30.09 Load Calc: (This Panel) Total Load Calc: Appliance Circuit - 1 Dishwasher Disposal Refrigerator Microwave A/C Unit - 240V Load Calc: (This Panel) Total Load Calc: Panel 2 of 2 Panel % of Sq.Ft:Panel % of 100% VA: Panel 1 of 2 Panel % of Sq.Ft:Panel % of 100% VA: Laundry Appliance Circuit - 2 /ce/ Astra v.2.080 2/14/2025 04:22 PM CAT 1 #AStamp Subject : Structural Certification for Proposed Residential Solar Installation. Job Number: 109R-506COUG; Rev A Client: KEVIN COUGHLIN Address: 1506 W 7th St, Santa Ana, CA 92703 Attn: To Whom It May Concern Signed on: 2/14/2025 A field observation of the existing structure at the address indicated above was performed. Structural evaluation of the loading was based on the site observations and the design criteria listed below. Design Criteria: • 2022 CRC/CBC/CEBC, 7-16 ASCE & 2018 NDS • Basic (Category II) Wind Speed V=96 mph, Exposure B • Ground Snow Load = 0 psf Based on this evaluation, I certify that the alteration to the existing structure by the installation of the PV system meets the requirements of the applicable existing and/or new building code provisions referenced above. Additionally, I certify that the PV module assembly including all attachments supporting it have been reviewed to be in accordance with the manufacturer's specifications. Results Summary (Hardware Check Includes Uplift Check on Attachments/Fastener, Structure Check Considers Main Structure) AR-01 Orientation Attachment Spacing/Cantilever Configuration Max DCR Result Landscape 64 / 25 Stacked 36%Pass Portrait 64 / 25 Stacked 24%Pass Roofing Material Pitch Structure Check Comp Shingle 18°Pass AR-02 Orientation Attachment Spacing/Cantilever Configuration Max DCR Result Landscape 64 / 25 Stacked 36%Pass Portrait 64 / 25 Stacked 24%Pass Roofing Material Pitch Structure Check Comp Shingle 18°Pass 225 Bush St. Suite 1400 San Francisco, CA 94104 Exp. 12/31/2026 Digitally Signed On: 02/14/25 Seismic Considerations: 10% Lateral Loading Increase Check Seismic Design Criteria (per USGS) Latitude Longitude Soil Site Class Ss S1 SDC 33.640302 -117.769442 D 1.237 0.443 D Site Conditions Module Type:LONGi Green Energy Technology Co Ltd: LR5-54HABB-400MTotal Mods:11 Sum of Roof Areas w/ PV:1254 Load Information Area Dead Load Total Weight Existing Roof 1254 sq ft 10 psf 12540 lb Ceiling 1254 sq ft 5 psf 6270 lb Interior Walls (Top Half)567 sq ft 5 psf 2833 lb Exterior Walls (Top Half)567 sq ft 9 psf 4816 lb System Weight PV 198 sq ft 3 psf 594 lb Lateral Loading 10% Check (2018 IEBC Section 503.4) Net Weight of PV System Net Weight of Roof % Increase of LFRS Final Result 594 lb 26459 lb 2.24%Pass AR-01 Roofing Material Roof Pitch Spacing Hardware Results Structural Results Comp Shingle 18°16''Pass Pass Hardware Calculations Attachment Information Attachment:Umbrella L Foot Uplift Force: 0.6(p - (3psf x cos(pitch))) x trib area =295 lb Uplift Capacity: 829 lb a = 4.0 ft Wind Design Criteria (Partially/Fully Enclosed Method, ASCE 7-16) Basic Wind Speed V 96 mph Wind Speed - Category II Wind Pressure Exposure Kz 0.57 Table 26.10-1 Topographic Factor Kzt 1.0 Figure 26.8-1 Wind Directionality Factor Kd 0.85 Table 26.6-1 Ground Elevation Factor Ke 1.00 Section 26.9 Velocity Pressure qh = 0.00256 x Kz x Kzt x Kd x Ke x V²11.39 psf Equation 26.10-1 Solar Adjustment Factors γe (Port/Land) =1.2 γa =0.535 Figure 29.4-8 Wind Pressures Zone 1 (up)Zone 2 (up)Zone 3 (up)Down Ext Pressure Coefficient GCp -1.95 -2.54 -3.02 0.57 Figures 30.3-2(A-H) Ultimate Design Wind Pressure p = qh x GCp x γe x γa -16.00 psf -16.00 psf -18.41 psf 16.00 psf Equation 29.4-7 Mod Orientation X-Spacing Cantilever Trib Area Demand DCR Final Result Landscape 64''25''9.9 ft²11.9 psf 36%Pass Portrait 64''25''15.1 ft²11.9 psf 24%Pass Structural Calculations Gravity Loading Summary Load Definitions Initial Pre-PV Load Code Factors Post-PV LoadPg =0 psf | Pf =0.7 x Ce x Ct x Pg Ps = Cs x Pf Roof Dead Load (D)DL 10.0 psf 10.0 psf 10.0 psf PV Dead Load (D)PV DL 3.0 psf 0.0 psf 3.0 psf Roof Live Load (Lr)RLL 20.0 psf 20.0 psf 1.00 0.0 psf Sloped Snow Load (Pf --> Ps)LL/SL 0.0 psf 0.0 psf 1.00 0.87 0.0 psf Total Design Load 30.0 psf 13.0 psf Cd Factor of Governing LC 1.25 (D+Lr)0.9 (D) Total Design Load (Normalized)24.0 psf 14.4 psf IEBC 5% Check Net Design Gravity Loading Change (Normalized w/ Cd Factor)-9.6 psf DCR: 60%Pass AR-02 Roofing Material Roof Pitch Spacing Hardware Results Structural Results Comp Shingle 18°16''Pass Pass Hardware Calculations Attachment Information Attachment:Umbrella L Foot Uplift Force: 0.6(p - (3psf x cos(pitch))) x trib area =295 lb Uplift Capacity: 829 lb a = 4.0 ft Wind Design Criteria (Partially/Fully Enclosed Method, ASCE 7-16) Basic Wind Speed V 96 mph Wind Speed - Category II Wind Pressure Exposure Kz 0.57 Table 26.10-1 Topographic Factor Kzt 1.0 Figure 26.8-1 Wind DIrectionality Factor Kd 0.85 Table 26.6-1 Ground Elevation Factor Ke 1.00 Section 26.9 Velocity Pressure qh = 0.00256 x Kz x Kzt x Kd x Ke x V²11.39 psf Equation 26.10-1 Solar Adjustment Factors γe (Port/Land) =1.2 γa =0.535 Figure 29.4-8 Wind Pressures Zone 1 (up)Zone 2 (up)Zone 3 (up)Down Ext Pressure Coefficient GCp -1.95 -2.54 -3.02 0.57 Figures 30.3-2(A-H) Ultimate Design Wind Pressure p = qh x GCp x γe x γa -16.00 psf -16.00 psf -18.41 psf 16.00 psf Equation 29.4-7 Mod Orientation X-Spacing Cantilever Trib Area Demand DCR Final Result Landscape 64''25''9.9 ft²11.9 psf 36%Pass Portrait 64''25''15.1 ft²11.9 psf 24%Pass Structural Calculations Gravity Loading Summary Load Definitions Initial Pre-PV Load Code Factors Post-PV LoadPg =0 psf | Pf =0.7 x Ce x Ct x Pg Ps = Cs x Pf Roof Dead Load (D)DL 10 psf 10.0 psf 10.0 psf PV Dead Load (D)PV DL 3 psf 0.0 psf 3.0 psf Roof Live Load (Lr)RLL 20 psf 20.0 psf 1.00 0.0 psf Sloped Snow Load (Pf --> Ps)LL/SL 0 psf 0.0 psf 1.00 0.87 0.0 psf Total Design Load 30.0 psf 13.0 psf Cd Factor of Governing LC 1.25 (D+Lr)0.9 (D) Total Design Load (Normalized)24.0 psf 14.4 psf IEBC 5% Check Net Design Gravity Loading Change (Normalized w/ Cd Factor)-9.6 psf DCR: 60%Pass PAGE REV: C 6/2/2025 KEVIN COUGHLIN 1506 1/2 W 7TH STREET SANTA  ANA CA USA 92703 PROJECT NUMBER:   109R-506COUG SHEET DESIGNER: ARJUN RAMESH CUSTOMER RESIDENCE: TEL. (714) 471-2941 APN: 405-072-03 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 COVER SHEET SCOPE OF WORK GENERAL NOTES PV-1.0 VICINITY MAP #SSTAMPCS #ESTAMPCS ABBREVIATIONS A AMPERE AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT (E)EXISTING ESS ENERGY STORAGE SYSTEM MSP MAIN SERVICE PANEL (N)NEW PRE-FAB PRE-FABRICATED PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS V VOLTS W WATTS SHEET INDEX REV NAME DATE COMMENTS MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. CEC 2022. CEC 2022. INVERTER. SYSTEM COMPLIES WITH 690.41(A). ARRAY ARE LIMITED TO LESS THAN 30V IN 30 SECONDS AND CEC 2022 690.12(B)(2)(2) WHERE CONDUCTORS INSIDE  THE ARRAY BOUNDARY IS LIMITED TO LESS THAN 80V IN 30 SECONDS VOLTAGE IN ACCORDANCE WITH CEC 706.20 AND EXCEPTION 1 CEC 706.20 (B).  THROUGH A WALL OR PARTITION PER 706.15(D).  THAN 6FT AND DOES NOT INCLUDE ANY ADDITIONAL OUTLETS OR DEVICES PER CEC 210.12(D). BY THE SINGLE LARGEST UTILIZATION EQUIPMENT CONNECTED TO THE SYSTEM PER CEC ARTICLE 710.15(A) LTD: LR5-54HABB-400M (MCI-2) ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE 1707000-XX-Y WITH INTERGRATED INVERTER: 13.5 kWh PER  PW3 TOTAL ENERGY CAPACITY (IN kWh): 27.0kWH, (1) TESLA: POWERWALL 3 EXPANSION 1807000-XX-Y ULTRA RAIL, ATTACHMENT DETAIL, UMBRELLA L  FOOT TO FRAMING, SNR-DC-00339 TRENCHING REQUIRED: AC WIRE TO BE TRENCHED 10 FT  IN  CONCRETE MATERIAL. MATERIAL. INSTALLED, SEE PV-4.0 FOR INTERCONNECTION DETAILS 1506 W 7th St Santa  Ana CA USA 92703 PAGE # DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-2.1 EQUIPMENT  ELEVATION PV-3.0 LAYOUT PV-3.1 MOUNTING DETAIL PV-4.0 ELECTRICAL PV-4.1 ELECTRICAL CONT. PV-4.2 ELECTRICAL CALCS PV-4.3 BACKUP LOAD CALCS PV-4.4  PANEL SCHEDULE PV-5.0 SIGNAGE PV-5.1 SIGNAGE 2 C ***The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown.*** Bldg #101122883 & Elect #20185406 APPROVALS: ELECT - M. Smith /ce/ PAGE REV: C 6/2/2025 KEVIN COUGHLIN 1506 1/2 W 7TH STREET SANTA  ANA CA USA 92703 PROJECT NUMBER:   109R-506COUG SHEET DESIGNER: ARJUN RAMESH CUSTOMER RESIDENCE: TEL. (714) 471-2941 APN: 405-072-03 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 PL PL SITE PLAN PV-2.0 #SSTAMPSP #ESTAMPSP LC ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS IN ACCORDANCE  WITH R328.4. ESS UNITS SHALL BE SEPARATED FROM EACH OTHER BY NOT  LESS THAN 3 FEET EXCEPT WHERE SMALLER SEPARATION DISTANCES ARE  DOCUMENTED TO BE ADEQUATE BASED ON LARGE/SCALE FIRE TESTING. NOTE: ROOFTOP MODULE LEVEL RAPID  SHUTDOWN DEVICE INSTALLED PER CEC  690.12 ARRAY  PITCH PV AREA  (SQFT) AR-01 18° 84.1 AR-02 18° 147.17360° TRUE  AZIM MAG  AZIM 168°180° 348° DC DISCONNECT(S) AC DISCONNECT(S) SOLAREDGE METER SUNRUN METER DEDICATED PV METER SPAN-PANEL PV LOAD CENTER SM SERVICE ENTRANCE  MAIN PANEL SE MP PM SP LEGEND  SCALE: NTS NOTE: NOT ALL ITEMS IN LEGEND  WILL APPEAR IN SITE PLAN LC INVERTER(S) AC INV DC SEM INTERIOR EQUIPMENT  SHOWN AS DASHED POWERWALL ENERGY  STORAGE SYSTEM (ESS) COMMUNICATION  WIRES METER ADAPTER BACKUP INTERFACE MICROGRID  INTERCONNECT DEVICE BACKUP LOADS PANEL ELECTRIC VEHICLE  SUPPLY EQUPMENT MDEV IQ COMBINER BOX ENERGY STORAGE  SYSTEM BPCB MA BIACREL METERAM GROUNDING  ELECTRODE  1  GP GENERATION PANEL RAIL STANDOFFS &  FOOTINGS SOLAR  MODULESBACKUP GATEWAYBG EXTERNAL  RAPID SHUTDOWN  SWITCH RSD SITE PLAN - SCALE = 3/34" = 1'-0" (E) RESIDENCE (N) ARRAY AR-01 (N) ARRAY AR-02 (E) PV ARRAY FIRE SETBACKS (18" TYP) ROOF PATHWAYS (3' TYP) ROOF PATHWAYS (3' TYP) MP SE INV AC MD AC AC AC INV          A A B B B B (E) PV  EQUIPMENT PATIO TYPE (E) PV ARRAY PATIO (TYP) DETACHED STRUCTURE (TYP) (E) GATE (TYP) (E) RESIDENCE (E) FENCE NOTES:  RESIDENCE DOES NOT CONTAIN ACTIVE FIRE  SPRINKLERS. ARRAY DETAILS:  TOTAL ROOF SURFACE AREA: 1621 SQFT.  TOTAL PV ARRAY AREA (E+N): 437.67 SQ FT.  PERCENTAGE PV COVERAGE (E+N): (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE  AREA) * 100 = 27% (N) AC CONDUIT RUN (ENTRENCHED ~ 10 FT TRENCHING DEPTH TO BE 21'') W 7TH ST A A A AA SP 1/2 W 7TH ST (ADU FILED UNDER  SEPARATE PERMIT) W 7TH ST C C Exp. 12/31/2026Digitally Signed On: 06/02/25 /ce/ PAGE REV: C 6/2/2025 KEVIN COUGHLIN 1506 1/2 W 7TH STREET SANTA  ANA CA USA 92703 PROJECT NUMBER:   109R-506COUG SHEET DESIGNER: ARJUN RAMESH CUSTOMER RESIDENCE: TEL. (714) 471-2941 APN: 405-072-03 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 #SSTAMP DESIGN CRITERIA MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF WIND SPEED:  96 MPH 3-SEC GUST. FASTENERS: (1) 5/16" DIA S.S. UMBRELLA  SCREW: 2.5" MIN EMBEDMENT  INTO FRAMING PV-3.0 LAYOUT SOLAR MODULE SNAPNRACK  RACKING 4" MODULE ELEVATION DETAIL - SCALE: NTS ROOF INFO FRAMING INFO ATTACHMENT INFORMATION Name Type Height Type Max  Span OC  Spacing Detail Max Landscape  OC Spacing Max Landscape  Overhang Max Portrait  OC Spacing Max Portrait  Overhang Configuration AR-01 COMP SHINGLE - UR -  UMBRELLA L FOOT 1-Story 2X6 RAFTERS 9'-8" 16" ULTRA RAIL, ATTACHMENT DETAIL,  UMBRELLA L FOOT TO FRAMING,  SNR-DC-00339 5'-4"2'-1"5'-4"2'-1"STACKED AR-02 COMP SHINGLE - UR -  UMBRELLA L FOOT 1-Story 2X6 RAFTERS 9'-8" 16" ULTRA RAIL, ATTACHMENT DETAIL,  UMBRELLA L FOOT TO FRAMING,  SNR-DC-00339 5'-4" 2'-1" 5'-4" 2'-1" STACKED INSTALLERS SHALL NOTIFY ENGINEER OF ANY  POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO  PROCEEDING W/ INSTALLATION. D1 - AR-01 - SCALE: 1/8" = 1'-0" AZIM: 180° PITCH:18° D2 - AR-02 - SCALE: 1/8" = 1'-0" AZIM: 360° PITCH:18° * IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12"  BOUNDARY REGION OF ANY ROOF PLANE EDGES  (EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE  ADDED AND OVERHANG REDUCED WITHIN THE 12"  BOUNDARY REGION ONLY AS FOLLOWS: ** ALLOWABLE ATTACHMENT SPACING INDICATED ON  PLANS TO BE REDUCED BY 50%. ** ALLOWABLE OVERHANG INDICATED ON PLANS TO  BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING  INDICATED ON PLANS. 5'-4" TYP 11'-2" 5'-6" 18'-4" 3" 1'-4" 8'-1"6'-1" 5'-4" 5" 5'-4" TYP 15'-1" 5'-8" 2'2'-11" 8'-8"6'-7" 4'-4" 1' 5'-4" TYP. C Exp. 12/31/2026Digitally Signed On: 06/02/25 /ce/ PAGE REV: C 6/2/2025 KEVIN COUGHLIN 1506 1/2 W 7TH STREET SANTA  ANA CA USA 92703 PROJECT NUMBER:   109R-506COUG SHEET DESIGNER: ARJUN RAMESH CUSTOMER RESIDENCE: TEL. (714) 471-2941 APN: 405-072-03 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 UR-40 RAIL | UR-60 RAIL FOR USE WITH SNAPNRACK ULTRA SERIES RAILS PENETRATION DETAIL INSTALLED SECTION VIEW DESCRIPTION:DRAWING NUMBER:SCALE:DESIGNER: APPROVED BY: REVISION: Sunrun South LLC 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 ● FAX (415) 580-6902 THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. ULTRA RAIL, ATTACHMENT DETAIL, UMBRELLA L FOOT TO RAFTERSNR-DC-00339 1 5 7 2019 NEW DETAIL 1 6 18 2019 DRO-00138 B 6 22 2023 DC002707 REV: ADATE: DNS 02/09/2025  DRAFTER:    M.AFFENTRANGER E.FERGUSON M.AFFENTRANGER Solar Mounting Solutions MJA MJA MJA BIN: 8 214" 112" 112" 15 8" SNAPNRACK ULTRA RAIL UMBRELLA L FOOT WITH UMBRELLA FLASHING FOR COMPOSTION ROOF MOUNTING REFER TO SNAPNRACK ENGINEERING CHARTS FOR APPLICABLE RAIL SPANS. "BIN" NUMBER ON CHART SHOULD MATCH "BIN" NUMBER ON THIS DRAWING 516"Ø S.S. UMBRELLA LAG SCREW MUST EMBED A MIN. OF 212" INTO STRUCTURAL MEMBER TO UTILIZE STANDARD SNAPNRACK ENGINEERING. REACH OUT TO SNAPNRACK IF THIS IS NOT POSSIBLE REFER TO SNAPNRACK INSTALLATION MANUAL FOR516"Ø HARDWARE TORQUE SPECIFICATIONS RAIL CAN BE MOUNTED ON EITHER SIDE OF THE L-FOOT FOR LEVELING DETAILS, REFER TO SNAPNRACK DETAIL DRAWING "SNR-DC-00447" STRUCUTRAL MEMBER, WOOD RAFTER, TYP. ROOF DECKING, TYP. SNAPNRACK5 16"n UMBRELLA LAG SCREW, S.S. COMP SHINGLE ROOFING, TYP. SNAPNRACK ULTRA RAIL SNAPNRACK UMBRELLA FLASHING 212" MIN. EMBEDMENT INTO WOOD MEMBER MODULE HEIGHT OFF ROOF: UR-40: 338" - 438" UR-60: 4" - 5" SNAPNRACK ULTRA RAIL UMBRELLA L FOOT STRUCUTRAL MEMBER, WOOD RAFTER, TYP. ROOF DECKING, TYP. COMP SHINGLE ROOFING, TYP. SNAPNRACK ULTRA RAIL UMBRELLA L FOOT WITH UMBRELLA LAG AND FLASHING SNAPNRACK UMBRELLA FLASHING PV-3.1 MOUNTING DETAIL C Exp. 12/31/2026Digitally Signed On: 06/02/25 PAGE REV: C 6/2/2025 KEVIN COUGHLIN 1506 1/2 W 7TH STREET SANTA  ANA CA USA 92703 PROJECT NUMBER:   109R-506COUG SHEET DESIGNER: ARJUN RAMESH CUSTOMER RESIDENCE: TEL. (714) 471-2941 APN: 405-072-03 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 FACILITY  GROUND 120/240 VAC SINGLE PHASE SERVICE EXISTING 200A MAIN BREAKER -END FED EXISTING 200A MAIN PANEL 200A  BUS M TESLA  BACKUP  SWITCH 60A UL 9540  FACTORY WIRING  ASSEMBLY (1 ) TESLA POWERWALL 3 EXPANSION PACK 1807000-XX-Y TESLA POWERWALL 3 1707000-XX-Y POWERWALL 3 1707000-XX-Y 11500 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT, POWER CONTROL SYSTEM 3 J-BOX LONGI GREEN ENERGY TECHNOLOGY CO LTD LR5-54HABB-400M STRING 1 OF 4 MODULES 2  MODULE LEVEL RAPID SHUTDOWN DEVICES LONGI GREEN ENERGY TECHNOLOGY CO LTD LR5-54HABB-400M STRING 2 OF 7 MODULES 3  MODULE LEVEL RAPID SHUTDOWN DEVICES 1 1 2 POINT OF INTERCONNECTION: CEC 2022 705.13, LOAD J-BOX 14 Hanwha Q CELLS: Q.PEAK DUO-G7 320 EEExisting SolarEdge Technologies: SE3800H-USE Existing Inverter(s)AC DISCONNECT  30A E (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A , 2P 120/240VAC 3 (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A , 2P 120/240VAC 3T (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A , 2P 120/240VAC 3 (N)125A LOAD CENTER (E) 20A PV BREAKER (N) (1) 60A PV+ESS BREAKER 4 E 80A 20A OCPD E (N) TESLA REMOTE METER  SOALR PV CURRENT  TRANSFORMERS PV-4.0 ELECTRICAL #ESTAMP MODULE CHARACTERISTICS LONGI GREEN ENERGY  TECHNOLOGY CO LTD:  LR5-54HABB-400M 400 W OPEN CIRCUIT VOLTAGE 37.05 V MAX POWER VOLTAGE 30.94 V SHORT CIRCUIT CURRENT 14.88 A C Installed at ADU 1506-1/2 W 7th--MAS(19) There are no backup loads in this project. MAS(19) The PV system EGC/GEC must be bonded to the ADU subpanelEGCbus. The neutral bus remains isolated. MAS(19) PAGE REV: C 6/2/2025 KEVIN COUGHLIN 1506 1/2 W 7TH STREET SANTA  ANA CA USA 92703 PROJECT NUMBER:   109R-506COUG SHEET DESIGNER: ARJUN RAMESH CUSTOMER RESIDENCE: TEL. (714) 471-2941 APN: 405-072-03 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 CONDUIT SCHEDULE TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT 1 Inverter Input (2) 10 AWG  (PV WIRE)N/A 6 AWG (BARE)Open Air 2 Inverter Input (4) 10 AWG  THHN/THWN-2 N/A 8 AWG THHN/THWN-2 3/4 EMT 3 Inverter Output (2) 6 AWG  THHN/THWN-2 (1) 6 AWG  THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT 3T Trenched Conduit (2) 6 AWG  THHN/THWN-2 (1) 6 AWG  THHN/THWN-2 8 AWG THHN/THWN-2 1" SCH 40  PVC 4 Load Center Output (2) 4 AWG  THHN/THWN-2 (1) 4 AWG  THHN/THWN-2 8 AWG THHN/THWN-2 1 EMT E Existing #ESTAMP POWER CONTROL SYSTEM (PCS): SOURCES OF SUPPLY DOES NOT EXCEED THE RATING OF ANY BUSBAR OR CONDUCTOR  SUPPLIED BY THE POWER PRODUCTION SOURCES MONITORED BY THE PCS SHALL COMPLY WITH ARTICLE 705.12. WITH 240.6(C).  SETPOINTS:           - 160A - MAXIMUM TOTAL CURRENT ON THE CONTROLLED PANEL           - 0A - FAIL SAFE GENERATION BACKFEED CURRENT SUPPLY (120% COMPLIANT) PV-4.1 ELECTRICAL CONT. IF THE RELOCATED LOADS EXTEND MORE THAN 6 FEET, AFCI PROTECTION APPLIES PER  2019 CEC 210.12 CITY REQUIRES TWO SOURCES OF GROUND - UFER, TWO GROUNDS RODS OR COLD  WATER GAS BOND ANY MULTIWIRE BRANCH CIRCUITS RELOCATED ARE TO BE IDENTIFIED, GROUPED, AND  EQUIPPED WITH A 2-POLE OCPD BREAKER  PER CEC 210.4(B,D). C PAGE REV: C 6/2/2025 KEVIN COUGHLIN 1506 1/2 W 7TH STREET SANTA  ANA CA USA 92703 PROJECT NUMBER:   109R-506COUG SHEET DESIGNER: ARJUN RAMESH CUSTOMER RESIDENCE: TEL. (714) 471-2941 APN: 405-072-03 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 Inverter Calculations Each Inverter has the following values which are calculated following these formulas: Inverter X: {[((Temp Coef Voc) x (Voc)) / 100] x (Low Temp - STC Temp) + Voc} * (# Modules / String) Inverter Powerwall 3 1707000-xx-y Inverter Overcurrent Protection:    (Inverter(s) Max Combined Current) x (Continous Load) =     48A x 1.25+20 = 80A   80A Overcurrent Protection USING PCS Wire ampacity calculated from 310.15(B)(16) & (17) as appropriate with ambient temperature calculations from  310.15(B)(3)(c) and raceway fill adjustments from 310.15(B)(3)(a). Conduit on the roof shall be installed no less than 1" above  the roof deck. PV Circuit conductor ampacity is constrained using the 75°C column with the continuous duty uprating or the  90°C column with the relevant ambient temperature and raceway fill adjustments without the continuous duty uprating per  690.8(B), whichever results with a larger wire size. Non-PV Circuit Conductors use the ampacity in the 75°C column or the  90°C column with the relevant ambient temperature and raceway fill adjustments, whichever is less (110.14(C) &  310.15(A)(2)). The rating of the conductor after adjustments shall be greater than, or equal to, the continuous duty uprated  current.  Calc Ex: Wire Ampacity x Ambient Temp. Corr. Factor x Conduit Fill Adj. Factor >= Output Current PV-4.2 ELECTRICAL CALCS  ALLOWABLE BACKFEED  MAX ALLOWED TOTAL GENERATION BACKFEED OCPD = MAIN BREAKER RATING =  200A  80A ≤ 200A→ INTERCONNECTION MEETS CEC 2022 705.13 REQUIREMENTS. C PAGE REV: C 6/2/2025 KEVIN COUGHLIN 1506 1/2 W 7TH STREET SANTA  ANA CA USA 92703 PROJECT NUMBER:   109R-506COUG SHEET DESIGNER: ARJUN RAMESH CUSTOMER RESIDENCE: TEL. (714) 471-2941 APN: 405-072-03 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 BACKUP LOADS LOAD BREAKER RATING  (AMPS)LABEL 1 20A-1P BEDROOM LIGHTS 2 20A-1P BEDROOM OUTELTS 3 20A-1P KIT APPLIANCE 4 20A-1P OUTDOOR LIGHTS 5 20A-1P FRIDGE 6 20A-1P KITCHEN OUTLETS 7 20A-1P KITCHEN LIGHTS 8 20A-1P BATHROOM LIGHTS 9 20A-1P BATHROOM OUTLETS 10 50A-2P A/C UNIT 11 60A-2P ADU SUB PANEL SUB PANEL LOADS 1 20A-1P ADU BATH OUT 2 20A-1P ADU FRIDGE 3 15A-1P ADU BATH LIGHTS 4 20A-1P ADU BED 1 OUTLET 5 20A-1P ADU BED 2 OUTLET 6 20A-1P ADU BED 1 LIGHTS 7 20A-1P ADU BED 2 LIGHTS 8 20A-1P ADU GARAGE 9 20A-1P ADU APPLIANCE 1 10 20A-1P ADU APPLIANCE 2 11 20A-1P FAU 12 15A-1P ADU KITCHEN LIGHTS 13 15A-1P ADU KITCHEN OUTLET PV-4.3 BACKUP LOAD  CALCS C PAGE REV: C 6/2/2025 KEVIN COUGHLIN 1506 1/2 W 7TH STREET SANTA  ANA CA USA 92703 PROJECT NUMBER:   109R-506COUG SHEET DESIGNER: ARJUN RAMESH CUSTOMER RESIDENCE: TEL. (714) 471-2941 APN: 405-072-03 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 PV-4.4 60 NEW 125A LOAD  CENTER (N) PV + ESS   BREAKER  EXSITING 200/200  MAIN PANEL MAIN BREAKER 20 (E) PV  BREAKER 20 0 20 20 20 20 60 20 20 20 20 20 50 20 BATHROOM OUTLETS BATHROOM LIGHTS KITCHEN OUTLETS ADU SUB PANEL FRIDGE BEDROOM OUTLETS KIT APPLIANCE OUTDOOR LIGHTS BEDROOM LIGHTS A/C UNIT (N)TESLA  REMOTE  METER PANEL SCHEDULE  FUTURE 200/200  MAIN PANEL 80 LOAD CENTER  FEEDER BREAKER MAIN BREAKER 20 0 60 20 20 20 20 20 50 20 20 20 20KITCHEN LIGHTS BATHROOM OUTLETS BATHROOM LIGHTS KITCHEN OUTLETS ADU SUB PANEL FRIDGE BEDROOM OUTLETS KIT APPLIANCE OUTDOOR LIGHTS BEDROOM LIGHTS A/C UNIT KITCHEN LIGHTS 20 20 20 20 20 2020 20 20 20 1 5 15 15 60 ADU BED 2 LIGHTS ADU BED 2 OUTLETS ADU KIT LIGHTS ADU KIT OUTLET ADU BATH LIGHTS FAU ADU FRIDGE ADU BED 1 OUTLET ADU BED 1 LIGHTS ADU BATH OUT ADU GARAGE ADU APPLIANCE 1 ADU APPLIANCE 2 EXISTING 100A  SUB-PANEL C PAGE REV: C 6/2/2025 KEVIN COUGHLIN 1506 1/2 W 7TH STREET SANTA  ANA CA USA 92703 PROJECT NUMBER:   109R-506COUG SHEET DESIGNER: ARJUN RAMESH CUSTOMER RESIDENCE: TEL. (714) 471-2941 APN: 405-072-03 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 SIGNAGE PV-5.0 #ESTAMP NOMINAL ESS VOLTAGE VAC LABEL LOCATION: ENERGY STORAGE SYSTEM PER CODE(S): NEC 706.15(C), CEC 706.15(C) 120 240 520 VDCMAXIMUM ESS DC VOLTAGE:60 ENERGY STORAGE SYSTEM DISCONNECT ENERGY STORAGE SYSTEM PREMISES WIRING MAY REMAIN  ENERGIZED AFTER LOSS OF  UTILITY POWER CAUTION! LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2022: 706.15(C), NEC 2020: 706.15(C) WARNING! DO NOT RELOCATE THIS  OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS  OCPD (IF APPLICABLE). PER CODE(S): NEC 2020: 705.12(B)(3)(2),  CEC 2022: 705.12(B)(3)(2) NOTES AND SPECIFICATIONS:   SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE  CEC 2022 ARTICLE 110.21(B), UNLESS SPECIFIC  INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF  REQUESTED BY THE LOCAL AHJ.  SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS  USING EFFECTIVE WORDS, COLORS AND SYMBOLS.  LABELS SHALL BE PERMANENTLY AFFIXED TO THE  EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND  WRITTEN.  LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND  THE ENVIRONMENT INVOLVED.  SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,  PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE  SPECIFIED.  DO NOT COVER EXISTING MANUFACTURER LABELS. SOLAR PV SYSTEM EQUIPPED  WITH RAPID SHUTDOWN SOLAR ELECTRIC  PV PANELS TURN RAPID SHUTDOWN  SWITCH TO THE "OFF"  POSITION TO SHUT DOWN  PV SYSTEM AND REDUCE  SHOCK HAZARD IN THE  ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE  DISCONNECTING MEANS TO WHICH THE PV SYSTEMS  ARE CONNECTED. PER CODE(S): NEC 2020: 690.56(C), CEC 2022: 690.56(C) 4" 3" ELECTRICAL SHOCK HAZARD WARNING TERMINALS ON LINE AND LOAD  SIDES MAY BE ENERGIZED IN  THE OPEN POSITION LABEL LOCATION: INVERTER(S),  AC/DC DISCONNECT(S),  AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020: 690.13(B), CEC  2022: 690.13(B) ! INVERTER 1 PHOTOVOLTAIC DC DISCONNECT MAXIMUM SYSTEM VOLTAGE:VDC550 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53 WARNING: PHOTOVOLTAIC  POWER SOURCE WARNING: PHOTOVOLTAIC  POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,  AT EACH TURN, ABOVE AND BELOW  PENETRATIONS,  ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2020: 690.31(D)(2), CEC 2022:  690.31(D)(2) LABEL LOCATION: INSTALLED WITHIN 3' OF RAPID SHUT DOWN  SWITCH PER CODE(S): NEC 2020: 690.56(C)(2),  CEC 2022: 690.56(C)(2), IFC 2018: 1204.5.3 RAPID SHUTDOWN SWITCH  FOR SOLAR PV SYSTEM WARNING! SOURCES: UTILITY GRID,  BATTERY AND PV SOLAR  ELECTRIC SYSTEM THREE POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN  SERVICE PANEL. PER CODE(S): NEC 2020: 705.12(C), CEC  2022: 705.12(C) LABEL LOCATION: BACKUP LOAD PANEL (MAIN PANEL) NO ADDITIONAL  LOADS TO BE  ADDED MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE:           48 AMPS   240     VAC LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF  INTERCONNECTION. PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54 PV SYSTEM DISCONNECT THIS EQUIPMENT FED BY  MULTIPLE SOURCES. TOTAL  RATING OF ALL OVERCURRENT  DEVICES EXCLUDING MAIN  SUPPLY OVERCURRENT DEVICE  SHALL NOT EXCEED AMPACITY OF  BUSBAR WARNING! LABEL LOCATION: PV LOAD CENTER (IF APPLICABLE) AND  ANY PANEL THAT UTILIZES "THE SUM  OF BREAKERS RULE". PER CODE(S): NEC 2020: 705.12 (B)(3)(3),  CEC 2022: 705.12 (B)(3)(3) WARNING: THIS SENSOR IS PART  OF A POWER CONTROL SYSTEM.  DO NOT REMOVE. REPLACE ONLY  WITH THE SAME TYPE AND RATING. WARNING: THIS SENSOR IS PART  OF A POWER CONTROL SYSTEM.  DO NOT REMOVE. REPLACE ONLY  WITH THE SAME TYPE AND RATING. REQUIREMENT: UL 1741, SECTION 206.3 LOCATION: AROUND THE CT WIRE  BY CLAMP SIZE 4.25" X 0.75" INVERTER 1 LABEL LOCATION: REQUIREMENT: UL 1741, SECTION 206.1 AND 206.4 LOCATION: MAIN PANEL SIZE: 4.25" X 1.25" PCS CONTROLLED CURRENT SETTING:  160A   THE MAXIMUM OUTPUT CURRENT FROM THIS SYSTEM IS CONTROLLED ELECTRONICALLY. REFER TO THE MANUFACTURER'S INSTRUCTIONS FOR MORE INFORMATION. C PAGE REV: C 6/2/2025 KEVIN COUGHLIN 1506 1/2 W 7TH STREET SANTA  ANA CA USA 92703 PROJECT NUMBER:   109R-506COUG SHEET DESIGNER: ARJUN RAMESH CUSTOMER RESIDENCE: TEL. (714) 471-2941 APN: 405-072-03 (415) 580-6920 ex3 Template_version_v5_2024 09 26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 PL PL PL PL SIGNAGE 2 PV-5.1 #ESTAMP CAUTION: 1506 1/2 W 7th Street Santa Ana CA USA 92703 SERVICE ENTRANCE AND  LOAD CENTER DISCONNECT PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10 MULTIPLE SOURCES OF POWER ESS DISCONNECT SYSTEM SHUTDOWN  DISCONNECT LABELING FORMAT LABELS SHALL BE RED PLASTIC MATERIAL WITH ENGRAVED WHITE LETTERS  MADE OF DURABLE ADHESIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR  THE ENVIRONMENT. LETTERS SHALL BE MINIMUM 3/8" IN SIZE. C Kevin coughlin 1506 w 7th st 717 17th Street,Ste.200 |Denver,CO 80202 Docusign Envelope ID:0FF7DD40-6DD1-48DB-AF2A-759275B9ABA1 2/25/2025 Certificate Of Completion Envelope Id: 0FF7DD40-6DD1-48DB-AF2A-759275B9ABA1 Status: Completed Subject: Complete with Docusign: uploaded-2025_02_24T21_37_16Z-Solar Authorization Letter.pdf Source Envelope: Document Pages: 1 Signatures: 1 Envelope Originator: Certificate Pages: 5 Initials: 0 Jamie Elgin AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) 225 Bush Street, Suite 1400 San Francisco, CA 94104 jamie.elgin@sunrun.com IP Address: 75.140.107.2 Record Tracking Status: Original 2/25/2025 8:02:26 AM Holder: Jamie Elgin jamie.elgin@sunrun.com Location: DocuSign Signer Events Signature Timestamp Kevin Coughlin kmecoughlin@gmail.com Security Level: Email, Account Authentication (None) Signature Adoption: Pre-selected Style Using IP Address: 99.9.137.112 Signed using mobile Sent: 2/25/2025 8:03:03 AM Viewed: 2/25/2025 11:35:42 AM Signed: 2/25/2025 11:35:49 AM Electronic Record and Signature Disclosure: Accepted: 2/25/2025 11:35:42 AM ID: 66db4456-bf6e-41a8-a21a-debb58a85300 In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 2/25/2025 8:03:03 AM Certified Delivered Security Checked 2/25/2025 11:35:42 AM Signing Complete Security Checked 2/25/2025 11:35:49 AM Completed Security Checked 2/25/2025 11:35:49 AM Payment Events Status Timestamps Electronic Record and Signature Disclosure CONSUMER DISCLOSURE From time to time, Sunrun Inc. (we, us or Company) may be required by law to provide to you certain written notices or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures electronically through the DocuSign, Inc. (DocuSign) electronic signing system. PLEASE READ THE INFORMATION BELOW CAREFULLY AND THOROUGHLY, AND IF YOU CAN ACCESS THIS INFORMATION ELECTRONICALLY TO YOUR SATISFACTION AND AGREE TO THESE TERMS AND CONDITIONS, PLEASE CONFIRM YOUR AGREEMENT BY CLICKING THE 'I AGREE' BUTTON AT THE BOTTOM OF THIS DOCUMENT. Getting paper copies At any time, you may request from us a paper copy of any record provided or made available electronically to you by us. You will have the ability to download and print documents we send to you through the DocuSign system during and immediately after signing session and, if you elect to create a DocuSign signer account, you may access them for thirty (30) days after such documents are first sent to you. After such time, if you wish for us to send you paper copies of any such documents from our office to you, please request delivery of such paper copies from us by following the procedure described below. Withdrawing your consent If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and disclosures electronically is described below. Consequences of changing your mind If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can complete certain steps in transactions with you and delivering services to you because we will need first to send the required notices or disclosures to you in paper format, and then wait until we receive back from you your acknowledgment of your receipt of such paper notices or disclosures. To indicate to us that you are changing your mind, you must withdraw your consent using the DocuSign ‘Withdraw Consent’ form on the signing page of a DocuSign envelope instead of signing it. This will indicate to us that you have withdrawn your consent to receive required notices and disclosures electronically from us and you will no longer be able to use the DocuSign system to receive required notices and consents electronically from us or to sign electronically documents from us. All notices and disclosures will be sent to you electronically Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you through the DocuSign system all required notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the disclosures and notices electronically or in paper format through the paper mail delivery system. If you do not agree with this process, please let us know as described below. Please also see the paragraph immediately above that describes the consequences of your electing not to receive delivery of the notices and disclosures electronically from us. Electronic Record and Signature Disclosure created on: 8/7/2013 10:17:58 AM Parties agreed to: Kevin Coughlin How to contact Sunrun Inc.: You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as follows: To contact us by email send messages to: customercare@sunrun.com You may also contact us in writing at 45 Fremont Street, 32nd Floor, San Francisco, CA 94105 or by phone at 1-855-478-6786. To advise Sunrun Inc. of your new e-mail address To let us know of a change in your e-mail address where we should send notices and disclosures electronically to you, you must send an email message to us at customercare@sunrun.com and in the body of such request you must state: your previous e-mail address, your new e-mail address. We do not require any other information from you to change your email address. In addition, you must notify DocuSign, Inc. at 1-866-219-4318 to arrange for your new email address to be reflected in your DocuSign account by following the process for changing e-mail in the DocuSign system. To request paper copies from Sunrun Inc. To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically, you must contact us by (a) sending us an e-mail to customercare@sunrun.com, (b) writing to us at Sunrun Inc, 45 Fremont Street, 32nd Floor, San Francisco, CA 94105, or (c) calling us at 1-855-478-6786, and in connection with your request you must state your e-mail address, full name, US Postal address, and telephone number. To withdraw your consent with Sunrun Inc. To inform us that you no longer want to receive future notices and disclosures in electronic format you may: i. decline to sign a document from within your DocuSign session, and on the subsequent page, select the check-box indicating you wish to withdraw your consent, or you may; ii. contact us by (a) sending us an email to customercare@sunrun.com, (b) writing to us at Sunrun Inc., 45 Fremont Street, 32nd Floor, San Francisco, CA 94105, or (c) calling us at 1-855-478-6786, and in connection with your request you must state your e-mail, full name, US Postal Address, and telephone number. We do not need any other information from you to withdraw consent.. The consequences of your withdrawing consent for online documents will be that transactions may take a longer time to process.. Required hardware and software Operating Systems: Windows® 2000, Windows® XP, Windows Vista®; Mac OS® X Browsers: Final release versions of Internet Explorer® 6.0 or above (Windows only); Mozilla Firefox 2.0 or above (Windows and Mac); Safari™ 3.0 or above (Mac only) PDF Reader: Acrobat® or similar software may be required to view and print PDF files Screen Resolution: 800 x 600 minimum Enabled Security Settings: Allow per session cookies ** These minimum requirements are subject to change. If these requirements change, you will be asked to re-accept the disclosure. Pre-release (e.g. beta) versions of operating systems and browsers are not supported. Notices Any notice or other communication to be made hereunder, even if otherwise required to be in writing under other provisions of this Consent or any other documents or agreements that have been provided to you in connection with this Consent, may alternatively be made in an electronic record transmitted electronically to the electronic addresses provided by you. Any notice or other communication made in electronic form will have the same legal effect and enforceability as if made in non-electronic form. Acknowledging your access and consent to receive materials electronically To confirm to us that you can access this information electronically, which will be similar to other electronic notices and disclosures that we will provide to you, please verify that you were able to read this electronic disclosure and that you also were able to print on paper or electronically save this page for your future reference and access or that you were able to e-mail this disclosure and consent to an address where you will be able to print on paper or save it for your future reference and access. Further, if you consent to receiving notices and disclosures exclusively in electronic format on the terms and conditions described above, please let us know by clicking the ‘I agree’ button below. By checking the ‘I agree’ box, I confirm that:  I can access and read and have accessed, read and understood the terms of this ELECTRONIC CONSENT TO ELECTRONIC RECEIPT OF ELECTRONIC CONSUMER DISCLOSURES document; and  I can print on paper the disclosure or save or send the disclosure to a place where I can print it, for future reference and access; and  Until or unless I notify Sunrun Inc. as described above, I consent to receive from exclusively through electronic means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to me by Sunrun Inc. during the course of my relationship with you. Entire Agreement Provision This agreement and the consumer disclosure statement executed by the customer in conjunction with and simultaneously with its review and acceptance of the terms set forth herein constitute the entire agreement between the parties with respect to the subject matter hereof and supersede any prior understandings, agreements, or representations by or between the parties, written or oral, to the extent they relate in any way to the subject matter hereof. Section 220.82 Dwelling Unit Part #1 - Section 220.82 (B)(1) General Lighting/Receptacles @ 3 VA per sq ft: Amps Box A (VA) 20.26 4863 Part #2 - Section 220.82 Size in VA Size in VA 1500 N/A 3000 N/A 1000 N/A 600 N/A 1000 N/A 1600 N/A N/A N/A N/A N/A N/A N/A N/A Amps Box B (VA) N/A 36.25 8700 Total VA from Parts #1 and #2 combined:Box A + Box B =13563 Total VA 13563 First 10,000 VA @ 100%10000 Remaining VA @ 40% Remaining VA =3563 3563 x 40% =1425.2 VA Adding First 10,000 VA 10000 VA Total VA for Gen. Lights/Recep, Appliances & Dedicated circuits:11425.2 VA Total AMP for Gen. Lights/Recep, Appliances & Dedicated circuits:47.61 Amps Part #3 - Section 220.82 (C) Heating and A/C loads: *Combine the larger loads of either the Heating or the A/C loads togther 100% of all the Heating or A/C loads in VA:9,600 VA 100% of all the Heating or A/C loads in Amps:40.00 A VA Volts Amps Parts #1 & #2 11425.2 240 47.61 Part #3 9,600 240 40.00 Total VA for all Parts:21,025 Totals Service/Feeder Load 87.61 #ESTAMP Laundry Appliance Circuit(s) Dishwasher(s) Disposal(s) Dedicated circuit House Square Footage 1621 Article 220 - Service/Feeder calculation for (address): 1506 W 7th St Santa Ana CA USA 92703 Building VA (watts) 4863 Amps 20.2625 Job Code 109R-506COUG Totals from all Parts Dedicated circuit Total for Part #1: OTHER Water Heater Refrigerator(s) Microwave(s) Totals for Part #2:Pool Equipment Dryer Range Oven Cooktop Bus Rating:200 Main Rating:200 41%37% Itemized House and 240V Loads for Panel: (VA) 1500 1500 9600 Not Fed by other panels Feeds: Panel 2 30.09 57.51 87.61 Bus Rating:100 Main Rating:60 59%63% Itemized House and 240V Loads for Panel: (VA) 1500 1000 600 1000 1600 Fed by: Panel 1 30.09 30.09 Load Calc: (This Panel) Total Load Calc: Appliance Circuit - 1 Dishwasher Disposal Refrigerator Microwave A/C Unit - 240V Load Calc: (This Panel) Total Load Calc: Panel 2 of 2 Panel % of Sq.Ft:Panel % of 100% VA: Panel 1 of 2 Panel % of Sq.Ft:Panel % of 100% VA: Laundry Appliance Circuit - 2 Rev: 8/29/19 Contractor Company Name: Contractor License Number: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org RESIDENTIAL PHOTOVOLTAIC CHECKLIST SUNRUN CA CL #750184 SOL-01 CBC 2016 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: 1506 W 7Th 1/2 St, Santa Ana, CA, 92703 YES NO Are the following applicable to the proposed project? 1.  Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.  Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.  Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.  Will the PV system weigh maximum 4 pounds per square feet or less? 5.  Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.  Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.  Will the PV system be installed without using any ballast system or counter-weight system? 8.  Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.  Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.  Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: 6.2 Email Address: caitlyn hernandez 3854005019 oc_permits@sunrun.com .25 /ce/ Astra v.2.080 2/14/2025 04:22 PM CAT 1 #AStamp Subject : Structural Certification for Proposed Residential Solar Installation. Job Number: 109R-506COUG; Rev A Client: KEVIN COUGHLIN Address: 1506 W 7th St, Santa Ana, CA 92703 Attn: To Whom It May Concern Signed on: 2/14/2025 A field observation of the existing structure at the address indicated above was performed. Structural evaluation of the loading was based on the site observations and the design criteria listed below. Design Criteria: • 2022 CRC/CBC/CEBC, 7-16 ASCE & 2018 NDS • Basic (Category II) Wind Speed V=96 mph, Exposure B • Ground Snow Load = 0 psf Based on this evaluation, I certify that the alteration to the existing structure by the installation of the PV system meets the requirements of the applicable existing and/or new building code provisions referenced above. Additionally, I certify that the PV module assembly including all attachments supporting it have been reviewed to be in accordance with the manufacturer's specifications. Results Summary (Hardware Check Includes Uplift Check on Attachments/Fastener, Structure Check Considers Main Structure) AR-01 Orientation Attachment Spacing/Cantilever Configuration Max DCR Result Landscape 64 / 25 Stacked 36%Pass Portrait 64 / 25 Stacked 24%Pass Roofing Material Pitch Structure Check Comp Shingle 18°Pass AR-02 Orientation Attachment Spacing/Cantilever Configuration Max DCR Result Landscape 64 / 25 Stacked 36%Pass Portrait 64 / 25 Stacked 24%Pass Roofing Material Pitch Structure Check Comp Shingle 18°Pass 225 Bush St. Suite 1400 San Francisco, CA 94104 Exp. 12/31/2026 Digitally Signed On: 02/14/25 Seismic Considerations: 10% Lateral Loading Increase Check Seismic Design Criteria (per USGS) Latitude Longitude Soil Site Class Ss S1 SDC 33.640302 -117.769442 D 1.237 0.443 D Site Conditions Module Type:LONGi Green Energy Technology Co Ltd: LR5-54HABB-400MTotal Mods:11 Sum of Roof Areas w/ PV:1254 Load Information Area Dead Load Total Weight Existing Roof 1254 sq ft 10 psf 12540 lb Ceiling 1254 sq ft 5 psf 6270 lb Interior Walls (Top Half)567 sq ft 5 psf 2833 lb Exterior Walls (Top Half)567 sq ft 9 psf 4816 lb System Weight PV 198 sq ft 3 psf 594 lb Lateral Loading 10% Check (2018 IEBC Section 503.4) Net Weight of PV System Net Weight of Roof % Increase of LFRS Final Result 594 lb 26459 lb 2.24%Pass AR-01 Roofing Material Roof Pitch Spacing Hardware Results Structural Results Comp Shingle 18°16''Pass Pass Hardware Calculations Attachment Information Attachment:Umbrella L Foot Uplift Force: 0.6(p - (3psf x cos(pitch))) x trib area =295 lb Uplift Capacity: 829 lb a = 4.0 ft Wind Design Criteria (Partially/Fully Enclosed Method, ASCE 7-16) Basic Wind Speed V 96 mph Wind Speed - Category II Wind Pressure Exposure Kz 0.57 Table 26.10-1 Topographic Factor Kzt 1.0 Figure 26.8-1 Wind Directionality Factor Kd 0.85 Table 26.6-1 Ground Elevation Factor Ke 1.00 Section 26.9 Velocity Pressure qh = 0.00256 x Kz x Kzt x Kd x Ke x V²11.39 psf Equation 26.10-1 Solar Adjustment Factors γe (Port/Land) =1.2 γa =0.535 Figure 29.4-8 Wind Pressures Zone 1 (up)Zone 2 (up)Zone 3 (up)Down Ext Pressure Coefficient GCp -1.95 -2.54 -3.02 0.57 Figures 30.3-2(A-H) Ultimate Design Wind Pressure p = qh x GCp x γe x γa -16.00 psf -16.00 psf -18.41 psf 16.00 psf Equation 29.4-7 Mod Orientation X-Spacing Cantilever Trib Area Demand DCR Final Result Landscape 64''25''9.9 ft²11.9 psf 36%Pass Portrait 64''25''15.1 ft²11.9 psf 24%Pass Structural Calculations Gravity Loading Summary Load Definitions Initial Pre-PV Load Code Factors Post-PV LoadPg =0 psf | Pf =0.7 x Ce x Ct x Pg Ps = Cs x Pf Roof Dead Load (D)DL 10.0 psf 10.0 psf 10.0 psf PV Dead Load (D)PV DL 3.0 psf 0.0 psf 3.0 psf Roof Live Load (Lr)RLL 20.0 psf 20.0 psf 1.00 0.0 psf Sloped Snow Load (Pf --> Ps)LL/SL 0.0 psf 0.0 psf 1.00 0.87 0.0 psf Total Design Load 30.0 psf 13.0 psf Cd Factor of Governing LC 1.25 (D+Lr)0.9 (D) Total Design Load (Normalized)24.0 psf 14.4 psf IEBC 5% Check Net Design Gravity Loading Change (Normalized w/ Cd Factor)-9.6 psf DCR: 60%Pass AR-02 Roofing Material Roof Pitch Spacing Hardware Results Structural Results Comp Shingle 18°16''Pass Pass Hardware Calculations Attachment Information Attachment:Umbrella L Foot Uplift Force: 0.6(p - (3psf x cos(pitch))) x trib area =295 lb Uplift Capacity: 829 lb a = 4.0 ft Wind Design Criteria (Partially/Fully Enclosed Method, ASCE 7-16) Basic Wind Speed V 96 mph Wind Speed - Category II Wind Pressure Exposure Kz 0.57 Table 26.10-1 Topographic Factor Kzt 1.0 Figure 26.8-1 Wind DIrectionality Factor Kd 0.85 Table 26.6-1 Ground Elevation Factor Ke 1.00 Section 26.9 Velocity Pressure qh = 0.00256 x Kz x Kzt x Kd x Ke x V²11.39 psf Equation 26.10-1 Solar Adjustment Factors γe (Port/Land) =1.2 γa =0.535 Figure 29.4-8 Wind Pressures Zone 1 (up)Zone 2 (up)Zone 3 (up)Down Ext Pressure Coefficient GCp -1.95 -2.54 -3.02 0.57 Figures 30.3-2(A-H) Ultimate Design Wind Pressure p = qh x GCp x γe x γa -16.00 psf -16.00 psf -18.41 psf 16.00 psf Equation 29.4-7 Mod Orientation X-Spacing Cantilever Trib Area Demand DCR Final Result Landscape 64''25''9.9 ft²11.9 psf 36%Pass Portrait 64''25''15.1 ft²11.9 psf 24%Pass Structural Calculations Gravity Loading Summary Load Definitions Initial Pre-PV Load Code Factors Post-PV LoadPg =0 psf | Pf =0.7 x Ce x Ct x Pg Ps = Cs x Pf Roof Dead Load (D)DL 10 psf 10.0 psf 10.0 psf PV Dead Load (D)PV DL 3 psf 0.0 psf 3.0 psf Roof Live Load (Lr)RLL 20 psf 20.0 psf 1.00 0.0 psf Sloped Snow Load (Pf --> Ps)LL/SL 0 psf 0.0 psf 1.00 0.87 0.0 psf Total Design Load 30.0 psf 13.0 psf Cd Factor of Governing LC 1.25 (D+Lr)0.9 (D) Total Design Load (Normalized)24.0 psf 14.4 psf IEBC 5% Check Net Design Gravity Loading Change (Normalized w/ Cd Factor)-9.6 psf DCR: 60%Pass