Text:
The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction.€The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown.
ID:
2
Creator:
Import Agent
Created:
2/25/2026 5:00 AM
Modified:
2/24/2026 11:49 AM
Text:
Bldg#: 101126163 Elec#:20187698 Approvals: Elec: MSmith
Stamp
ID:
1
Creator:
Import Agent
Created:
2/25/2026 5:00 AM
Modified:
2/24/2026 11:49 AM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SCOPE OF WORK GENERAL NOTES <br />VICINITY MAPABBREVIATIONS <br />A AMPERE <br />AC ALTERNATING CURRENT <br />AFC ARC FAULT CIRCUIT INTERUPTER <br />AZIM AZIMUTH <br />COMP COMPOSITION <br />DC DIRECT CURRENT <br />(E)EXISTING <br />ESS ENERGY STORAGE SYSTEM <br />MSP MAIN SERVICE PANEL <br />(N)NEW <br />PRE-FAB PRE-FABRICATED <br />PSF POUNDS PER SQUARE FOOT <br />PV PHOTOVOLTAIC <br />RSD RAPID SHUTDOWN DEVICE <br />TL TRANSFORMERLESS <br />V VOLTS <br />W WATTS <br />SHEET INDEX <br />PAGE <br />REV: E 2/12/2026 <br />JULIE VO <br />3455 S CRAWFORD GLEN, <br />SANTA ANA, CA, 92704 <br />PROJECT NUMBER: <br /> 109R-455VO PR-3004660114 <br />SHEET <br />DESIGNER: <br />SREERAJ P R <br />CUSTOMER RESIDENCE: <br />TEL. (309) 660-0844 <br />APN: 412-531-51 <br />(415) 580-6920 ex3 <br />PV-1.0 <br />#ESTAMP#SSTAMP <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />COVER SHEETREV NAME DATE COMMENTS <br />D KYLE CARTER 1/12/2026 AHJ REDLINES <br />E RAJIV BOODRAM 2/10/2026 AHJ REDLINES <br />• ALL WORK SHALL GENERALLY CONFORM WITH 2025 CRC/CBC/CEBC, 7-22 ASCE & 2024 NDS, MUNICIPAL CODE, AND <br />ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. <br />• PHOTOVOLTAIC SYSTEM WILL COMPLY WITH CEC 2025. <br />• ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH CEC 2025. <br />• PHOTOVOLATIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM <br />COMPLIES WITH 690.41(A) <br />• MODULES CONFORM TO AND ARE LISTED UNDER UL 61730. <br />• INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. <br />• RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. <br />• SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED. <br />• RAPID SHUTDOWN SYSTEM IN COMPLIANCE WITH CEC 2025 690.12(B)(1) WHERE CONDUCTORS OUTSIDE OF THE <br />ARRAY ARE LIMITED TO LESS THAN 30V IN 30 SECONDS AND CEC 2025 690.12(B)(2)(2) WHERE CONDUCTORS INSIDE <br />THE ARRAY BOUNDARY IS LIMITED TO LESS THAN 80V IN 30 SECONDS <br />• CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(D). <br />• ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. <br />• 14.22 AMPS MODULE SHORT CIRCUIT CURRENT. <br />• 22.22 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a)(1) & 690.8 (b)]. <br />• ENERGY STORAGE SYSTEM CONFORMS TO AND IS LISTED UNDER UL 9540. <br />• ENERGY STORAGE SYSTEM LIVE PARTS ARE NOT ACCESSIBLE DURING ROUTINE MAINTENANCE. SYSTEM <br />VOLTAGE IN ACCORDANCE WITH CEC 706.20 AND EXCEPTION 1 CEC 706.20 (B). <br />• ADDITIONAL DISCONNECTING MEANS SHALL BE INSTALLED WHERE THE CIRCUITS FROM THESE TERMINALS PASS <br />THROUGH A WALL OR PARTITION PER 706.15(D). <br />• LISTED, COMBINATION TYPE AFCI SHALL BE INSTALLED WHERE BACKED UP CIRCUIT WIRING IS EXTENDED MORE <br />THAN 6FT AND DOES NOT INCLUDE ANY ADDITIONAL OUTLETS OR DEVICES PER CEC 210.12(D). <br />• ALL PASS-THROUGH CONDUCTORS MUST COMPLY WITH CEC 312.8 <br />• THE CAPACITY OF THE STANDALONE SYSTEM SUPPLY SHALL BE EQUAL TO OR GREATER THAN THE LOAD POSED <br />BY THE SINGLE LARGEST UTILIZATION EQUIPMENT CONNECTED TO THE SYSTEM PER CEC ARTICLE 710.15(A) <br />• SYSTEM SIZE: 18.92KW DC, 23.0KW AC <br />• MODULES: (43) Silfab SIL-440QD-DCA <br />• RAPID SHUTDOWN: (17) TESLA MID CIRCUIT INTERRUPTER <br />(MCI) ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE <br />• • ENERGY STORAGE SYSTEM: (2)TESLA: POWERWALL 3 <br />1707000-XX-Y, 13.5 KWH. <br />(1) TESLA: POWERWALL 3 EXPANSION 1807000-XX-Y <br />TOTAL ENERGY CAPACITY: (IN KWH): 40.5KWH <br />BACKUP GATEWAY: (1) 200A TESLA POWERWALL CONTROL <br />PANEL <br />• RACKING: ULTRAFOOT RAIL TO FRAMING SNR-DC-01507 <br />• POWER-CONTROLLED SYSTEM (PCS) ENABLED EQUIPMENT <br />INSTALLED, SEE PV-4.0 FOR INTERCONNECTION DETAILS <br />3455 S Crawford <br /> Glen Santa <br />Ana CA USA 92704 <br />(1) HARDWIRED RESIDIO PROSERIES A7 HOME <br />MONITORING SYSTEM (HEAT ALARM) <br />PAGE # DESCRIPTION <br />PV-1.0 COVER SHEET <br />PV-2.0 SITE PLAN <br />PV-2.1 ELEVATION DETAIL <br />PV-2.2 GARAGE FLOOR PLAN <br />PV-3.0 LAYOUT <br />PV-3.1 MOUNTING DETAIL <br />PV-4.0 ELECTRICAL <br />PV-4.1 ELECTRICAL CONT. <br />PV-4.2 ELECTRICAL CALCS <br />PV-4.3 BACKUP LOAD CALCS <br />PV-4.4 PANEL SCHEDULE <br />PV-5.0 SIGNAGE <br />PV-5.1 SIGNAGE 2