HomeMy WebLinkAbout2129 N Hathaway St #2 - Plan Date: 1/30/2026 PROFESSIONAL BUILDING DESIGNS, INC. 11122 BIXLER CIR GARDEN GROVE CA 92840 PHONE: 657-820-6210 EMAIL: INFO@PBDINC.ORG RESPONSE TO PLAN CHECK#1 ********************** CLIENT : MR. JULIO VALDEZ. PROJECT NAME : 2 CAR GARAGE CONVERT TO ADU. LOCATION : 2129 N HATHAWAY ST. SANTA ANA, CA 92705. JOB NUMBER : 25655. Structural requirements: S1.0 Please see the updated foundation plan and Details 3/SD1 and 16/SD1 for revisions per city mark-ups. DESIGNED BY: TUNG VO, M.S., P.E. PROFESSIONAL BUILDING DESIGNS, INC. 11122 BIXLER CIR GARDEN GROVE CA 92840 PHONE: 657-820-6210 EMAIL: INFO@PBDINC.ORG 2nd SUBMITAL: January 30, 2026 VERTICAL, LATERAL DESIGNED BY: TUNG VO, M.S., P.E. STRUCTURAL ANALYSIS ********************** SUBMITAL FOR BUILDING DEPARTMENT CLIENT : MR. JULIO VALDEZ. PROJECT NAME : 2 CAR GARAGE CONVERT TO ADU. LOCATION : 2129 N HATHAWAY ST. SANTA ANA, CA 92705. JOB NUMBER : 25655. DESIGN CRITERIA SHEET Job# 25655 CODE: 2022 CALIFORNIA BUILDING CODE In all cases calculations will supersede this design criteria sheet. TIMBER Douglas fir-larch-19% max. moisture content. 4X Members: No .2 or Better 6X,8X Beams and Headers: No.1 or Better 2X Joists and Rafters: No. 2 or Better Plates and Blocking: Standard Grade or Better Studs: Stud Grade or Better Mud Sills: Pressure Treated Utility Grade or Better CONCRETE 1.Drypack shall be composed of one part Portland cement to not more than three -part sand. 2.All structural concrete…………………………. f’c=2500 psi w/inspection. All slab-on –grate/continuous footing /pads……… f’c=2500 psi w/inspection. All concrete shall reach minimum compressive strength at 28 days. REINFORCING STEEL 1. All reinforcing shall be A.S.T.M.A-615-40 for #4 bars and smaller, A-615-60 for #5 bars and larger. Welded wire fabric to be A.S.T.M. A-185, lab 1-1/2 spaces ,9” min. 2. Development length of Tension Bars shall be calculated per ACI318-19 Section 12.2.2. Class B splice =1.3xld. Splice lengths for 2500 psi concrete is: # 4 Bars (40k) =21”, #5 Bars (60k) =39”, #6 Bars (60k) =47” (30 dia. for compression). Masonry reinforcement shall have lappings of 48dia.or 2’-0”. This is in all cases U.N.O. 3. All reinforcing bars shall be accurately and securely placed before pouring concrete, or grouting masonry. 4. Concrete protection for reinforcement shall be at least equal to the diameter of the bars. Cover for cast-in-place concrete shall be as follows, U.N.O: A. Concrete cast against & permanently exposed to earth…………………3” B. Concrete exposed to earth or weather <= #5 Bar ………………………1 ½” #6#18 bars 2” C. Concrete not exposed to weather or in contact with ground Slab, wall, joist, <= #11bars …………………………………………… 3/4” Beams & Columns: Primary reinforcement, ties, stirrups, spirals………….1 ½” STRUCTURAL STEEL 1. Fabrication and erection of structural steel shall be in accordance with “specification for the Design, Fabrication and Erection of Structural Steel Buildings “, AISC, current edition. Steel to conform to ASTM A992.Round pipe columns shall conform to ASTM A35, Grade B.Square /Rectangular Steel tubes ASTM A500,Grade B . 2. All welding shall be performed by certified welders, using the Electric Shielded Arc Process at licensed shops or otherwise approved by the Bldg. Dept. Continuous inspection required for all field welding. 3. All steel exposed to weather shall be hot –dip galvanized after fabrication, or other approved weatherproofing method 4. Where finish is attached to structure steel, provide ½”  both holes @ 4’-0” O.C. for attachment of nailers, U.N.O. see architectural drawings for finishes (nelson studs ½”x3” CPL may replace bolts). MASONY 1. Concrete block shall be of size shown on architectural drawing and/or called for in specifications and conform to ASTM C-90-09, grade A normal weight units with max. linear shrinkage of 0.06% 2. All vertical reinforcing in masonry walls not retaining earth shall be located in the center of the wall (U.N.O.), retaining walls are to be as shown in details. 3. All cells with steel are to be solid grouted (except retaining walls where all cells are to be solid grouted). LOADING & LATERAL ANALYSIS (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code) Job Number : 25655 Plan : GENERAL INPUT : Code :2022 CBC Wind Speed:95 mph Risk Category :II Wind Exposure:C Importance Factor, I (Seis.)1.00 Mean Roof Height :11.25 ft Soil Site Class :D Building Width, B :40 ft Seismic Category :D Building Lenght, L :61.25 ft Spectral Accel., Ss :1.315 Typ. Roof Slope:4/12 Spectral Accel., S1 :0.468 Risk Category II Structure Height, hn :11.25 ft Topographic Factor Kzt 1.00 Seismic Resist. System (R) :6.5 Direction Factor Kd :0.85 Soil Bearing Pressure:1500 psf Gust Effect Factor G :0.85 Concrete Strength:2500 psi Gcpi(+/-)0.18 Foundation Type : Conventional Load Combination Factor (W) :1.00 ANALYSIS SEISMIC DESIGN :(Using Equivalent Force Procedure per ASCE 7-16) Site Coefficients : Fa ==1.20 (ASCE 7-16 Table 11.4-1) Fv ==1.80 (ASCE 7-16 Table 11.4-2) Maximum Spectral Response Accelerations : SMS=Fa*Ss =1.58 (USGS Seismic Design Geodatabase) SM1=Fv*S1 =0.84 (USGS Seismic Design Geodatabase) Design Spectral Accelerations : SDS=SMS*2/3 =1.052 SD1=SM1*2/3 =0.56 Determine Building Period : Ta=Ct*(hn^x)=0.123 sec. (Approximate Fundemental Period using Eq. 12.8-7) TL =8.000 sec. (Long-period transition period per ASCE 7-16 Maps 22-15/20) Ct =0.020 x =0.750 Seismic Response Coefficients : Cs=0.7*SDS*I/(R)=0.113 (ASCE 7-16 Section 12.8-2)CONTROL Cs-max 0.703 (Eq. 12.8-3 & 12.8-4) Cs-min 0.010 (Eq. 12.8-5 & 12.8-6) ANALYSIS WIND DESIGN :(MWFRS Directional Procedure Chapter 27 Part1 per ASCE 7-16 for Building of any Height- See detail on pages Lateral Analytical Section ) LOADDING CONDITIONS : ROOF LOADING :FLOOR LOADING : Slope : Roof Material : 5.50 Floor Material : 4.00 Built-up : 3.50 Built-up : 0.00 Sheathing : 1.50 Sheathing : 3.00 Roof Rafters : 1.50 Floor Joist : 1.50 Ceiling Joist : 1.50 Carpet : 1.00 Drywall : 1.50 Drywall : 2.50 Miscellaneous : 5.00 Miscellaneous : 3.00 Total Dead Load(D.L) : 20.00 psf Total Dead Load(D.L) : 15.00 psf Live Load (L.L) : 20.00 psf Live Load (L.L) : 40.00 psf Snow Load : WALL LOADING :CEILING LOADING : Exterier Wall :(DL )15.00 psf Dead Load :6.00 psf Interier Wall :10.00 psf Live Load :10.00 psf BEAM DESIGN Job Number 25655 Plan :1 Code : AF&PA NDS-2018 Design Method:ASD Load Combination: 2021 IBC/2022 CBC & ASCE 7-16 All timber shall be Douglas Fir-Larch-19% max .moisture content. Timber Properties : Sawn Lumber(DFL) 2X Josit& Rafters(No.2) 4X Swan Beams(No.2) 6X Swan Beams(No.1) Glued Laminated Beam Glulam 24F-V4 DF/DF Glued Laminated Beam TimberStrand LSL 1.55E Parallam PSL 2.0E Microllam LVL 1.9E Wood Post Axial Loads Capacity: POST HEIGHT (FT) Post 7 8 9 10 12 14 18.67 22 2x4 DFL STANDARD 3.29 2.64 2.14 1.76 1.25 0.93 --- --- 2x4 DFL STUD 2.89 2.42 2.01 1.69 1.22 0.91 ------ 4x4 DFL No.2 8.73 7.00 5.69 4.69 3.33 2.48 --- --- 2x6 DFL STUD 5.16 5.16 5.16 4.93 4.00 3.18 1.94 1.43 2x6 DFL No.2 5.16 5.16 5.16 5.16 5.06 3.88 2.28 1.67 4x6 DFL No.2 13.58 10.93 8.90 7.35 5.22 3.89 --- --- 4x8 DFL No.2 17.71 14.30 11.67 9.66 6.87 5.12 --- --- 4x10 DFL No.2 22.32 18.10 14.81 12.27 8.74 6.52 ------ 4x12 DFL No.2 27.15 22.01 18.01 14.92 10.63 7.93 --- --- 6x6 DFL No.1 26.37 24.84 23.01 20.99 16.90 13.42 8.15 6.00 6x8 DFL No 1 35.96 33.87 31.38 28.62 23.05 18.30 11.11 8.19 8x8 DFL No.1 52.82 51.56 50.01 48.16 43.51 37.99 25.86 19.67 Fb Fv E 900 900 180 1.6 E 180 1.6 E 1350 170 1.6 E 265 1.8 E2400/1850 2.0 E 1.9 E 1.55 E2350 2900 2600 310 285 285 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)296 @ 2 1/2"3281 (3.50")Passed (9%)--1.0 D + 1.0 L (All Spans) Shear (lbs)262 @ 1' 3/4"1665 Passed (16%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1308 @ 9' 3"1765 Passed (74%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.304 @ 9' 3"0.603 Passed (L/714)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.486 @ 9' 3"0.904 Passed (L/446)--1.0 D + 1.0 L (All Spans) Member Length : 18' 6" System : Ceiling Member Type : Attic Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor/Ceiling Live Factored Accessories 1 - Stud wall - DF 3.50"3.50"1.50"111 185 296 Blocking 2 - Stud wall - DF 3.50"3.50"1.50"111 185 296 Blocking •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)8' 11" o/c Bottom Edge (Lu)18' 6" o/c • Only vertical loads are available for Attic Joist member types. No tension loading will be considered in the design for these members. Dead Floor/Ceiling Live Vertical Load Location (Side)Spacing (0.90)(1.00)Comments 1 - Uniform (PSF)0 to 18' 6"24"6.0 10.0 Ceiling Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED ROOF, R1 : CJ over Bedroom 1 piece(s) 2 x 10 DF No.2 @ 24" OC ForteWEB Software Operator Job Notes 11/20/2025 1:32:05 PM UTC Tung Vo (714) 928-2006 ForteWEB v3.9, Engine: V8.4.3.94, Data: V8.1.7.3 File Name: 25655 Page 3 / 5 SHEARWALL DESGIN GENERAL (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code)Job Number :25655 Plan : GENERAL MATERIALS Code : AF&PA NDS-2018 &SDPWS-2021(ASD) Descript. Material Size Design Method : Segment & FTAO Top Plate DF/SPine 2-2X4 Min. Load Combo : 2021 IBC/2022 CBC & ASCE 7-16 Sill Plate DF/SPine 2X4 Min. HD Manufacturer : SIMPSON Wall Stud DF/SPine 2X4 @ 16" O.C. Min.(U.N.O) Panel Schedule : 2022 CBC Chord DF/SPine 2X4 Min. 2022 CBC 16d's Sinker SDS Screws(*) 1 260 6" O.C. 16" O.C. 24" O.C. 2 380 4" O.C. 12" O.C. 16" O.C. 3 490 3" O.C. 8" O.C. 12" O.C. 4 640 2" O.C. 6" O.C. 10" O.C. 5 800 (2) 3" O.C. 5" O.C. 6" O.C. 3(D.S.)1020 (2) 3" O.C. 4" O.C. N/A 4(D.S.)1330 (2) 3" O.C. 3" O.C. N/A 5(D.S.)1740 (2) 3" O.C. 2.5" O.C. N/A Notes: -(*) Use 1/4"dia. x6"SDS Screws DRAG TYPE FORCE SCHEDULE Type A B C D E F FORMULAS MAXIMUM SHEAR WALL DEFLECTION: ( IBC Section 2305.3 / SDPWS-08 4.3.2) Top Plate Splice Simpson MST48 or ALT.(32)16d sinker per top plate splice sheae -Periodic Special Inspection is Required. -Use Spacing Per Schedule If Number Of Framing Clips Are Not Specified On Framing Plans. -For Holdown Attached To Inside Face Of End Post. Load Capacity Simpson MSTC52 or ALT.(36)16d sinker per top plate splice 1192 2134 3230 4267 4745 5653 Simpson ST22 or ALT.(10)16d sinker per top plate splice Simpson ST6224 or ALT.(16)16d sinker per top plate splice Simpson ST6236 or ALT.(22)16d sinker per top plate splice Simpson MST37 or ALT.(24)16d sinker per top plate splice Sill Plate Connection Framing(2) Clips SHEAR WALL SCHEDULE of 10d's @ 12" O.C. 15/32" Allowable Shear(plf)Sheathing (Plywood/OSB) 3/8" 15/32" 8d's @ 6" O.C. 8d's @ 4" O.C. 8d's @ 3" O.C. 8d's @ 12" O.C. 8d's @ 12" O.C. 8d's @ 12" O.C. 8d's @ 12" O.C. 3/8" 15/32" 10d's @ 4" O.C. 10d's @ 3" O.C. 10d's @ 12" O.C. 10d's @ 12" O.C. 10d's @ 12" O.C. 15/32" Panel Type Edge Nail (common) Field Nail (common) 3/8" 3/8" -Provide 3" Nominal Or Wider Framing At Adjoining Panel Edges With Nails Staggered. -Use Clips @ 6" O.C. On Simpson Strong Wall & Hardy Frame (U.N.O.). -Use Spacing Per Schedule If Number Of Framing Clips Are Not Specified On Framing Plans. -Sheathing Conforms to Either Doc PS 1 Or PS 2 Standards. 8d's @ 2" O.C. 10d's @ 2" O.C. 10d's @ 2" O.C. -Sheathing Panel Joint And Sill Plate Nailing Shall Be Staggered In All Cases. 38 0.75b b a Bending Shear Nail slip Chord splice slip n w w h hv h v dheEA GtL L D = + + + = + + +D D D D 38 0.75b b a Bending Shear Nail slip Chord splice slip n w w h hv h v dheEA GtL L D = + + + = + + +D D D D 38 0.75b b a Bending Shear Nail slip Chord splice slip n w w h hv h v dheEA GtL L D = + + + = + + +D D D D 38 0.75b b a Bending Shear Nail slip Chord splice slip n w w h hv h v dheEA GtL L D = + + + = + + +D D D D W/H W/H REF. (N) WALL (E) WALL WALL LEGEND Job Number : 25655LATERAL SHEAR WALL LAYOUT Plan : ROOF SHEAR WALL LAYOUT SECTION 1 21 LATERAL ANALYTICAL SECTION (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code)Job Number : 25655 1 Plan : GENERAL INPUT : (1 STORY) Base Height Above Ground (ft)0.50 Plate Height (ft)8.00 South Roof Height (N-S Direction-ft)12.00 West Roof Height (E-W Direction-ft)10.75 South Roof Type (N-S Direction) Slope West Roof Type (E-W Direction) Gable Roof Depth (N-S-ft)24.25 Roof Depth (E-W-ft)24 Diaphragm Depth (N-S Direction-ft)19 Diaphragm Depth (E-W Direction-ft)21 Diaphragm Span (N-S Direction-ft)21 Diaphragm Span(E-W Direction-ft)19 Number of Ext. Wall (N-S)2 Number of Ext. Wall (E-W)2 Number of Int. Wall (N-S)1.5 Number of Int. Wall (E-W)0.5 SEISMIC ANALYSIS :(Using Equivalent Force Procedure per ASCE 7-16) Determine Section Weight : For N-S Direction : Area(ft^2) Unit Roof 582 20 Ext.Wall(ft.)168 15 Int. Wall(ft)126 10 Sum:15,420 Ev(ASD) Base Shear :(V=Cs*W) :1,747.0 3244 lbs 3 72.75 For E-W Direction : Area(ft^2) Unit Roof 582 20 Ext.Wall(ft.)152 15 Int. Wall(ft)38 10 Sum:14,300 Ev(ASD) Base Shear :(V=Cs*W) :1,620.1 3009 lbs 2.78 66.7 WIND ANALYSIS :(MWFRS Directional Procedure Chapter 27 Part1 per ASCE 7-16 for Building of any Height) The Velocity Pressures : qz = 0.00256 Kz Kzt Kd V2 (ASCE 7-16 Equation27.3-1) Kzt = 1.0 (Flat Terrian) Kd = 0.85 (ASCE 7-16 Table 26.6-1) Kz = 2.01*(max(z,15)/zg)(2/a)( ASCE 7-16 Tables 27.3-1) h(ft)kz qz(psf) Roof 10.67 0.849 16.67 Wall 8.00 0.849 16.67 p=qz*G*Cp-qi*(+/-GCpi) for windward wall (psf), where : qi=qh(Eq. 27.3-1, Sect.27.3.2) p=qh*G*Cp-qi*(+/-GCpi) for leeward wall, side wall & roof (psf), where : qi=qh( Eq. 27.3-1, Sect.27.3.2) The Internal Pressures: Gcpi(+/-) 0.18 qh 16.67 psf +qhGCpi 3 psf -qhGCpi -3 psf (see next page for details) SECTION NUMBER : Weight(Ib) 11640 2520 1260 Unit FN-S(psf) Unit FN-S(plf) Weight(Ib) 11640 2280 380 Unit FE-W(psf) Unit FE-W(plf) LATERAL ANALYTICAL SECTION (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code) Job Number : 25655 SECTION NUMBER : 1 (cont.)Plan : Normal to Ridge Wind Load Tabulation for MWFRS with q ≥ 10o(N-S Direction): (w/+Gcpi) (w/-Gcpi) All 0.80 16.67 14.34 8.34 Cond.1 -0.36 16.67 -2.14 -8.14 Cond.2 0.14 16.67 4.95 -1.05 All -0.57 16.67 -5.06 -11.06 All -0.39 16.67 -2.58 -8.58 All -0.70 16.67 -6.92 -12.92 Design Sumary Wind Loading (N-S Direction): Horizontal Vertical Roof 9.50 3.50 1st Floor 16.92 0.00 105.67 plf Parallel to Ridge Wind Load Tabulation for MWFRS (E-W Direction): (w/+Gcpi) (w/-Gcpi) Roof 0.80 16.67 14.34 8.34 Wall 0.80 16.67 14.34 8.34 Cond.1 -0.90 16.67 -9.75 -15.75 Cond.2 -0.18 16.67 0.45 -5.55 Cond.1 -0.90 16.67 -9.75 -15.75 Cond.2 -0.18 16.67 0.45 -5.55 Cond.1 -0.50 16.67 -4.08 -10.08 Cond.2 -0.18 16.67 0.45 -5.55 Cond.1 N/A N/A N/A N/A Cond.2 N/A N/A N/A N/A All -0.50 16.67 -4.08 -10.08 All -0.70 16.67 -6.92 -12.92 Design Sumary Wind Loading (E-W Direction): Horizontal Vertical Roof 18.42 4.98 Wall 18.42 0.00 124.34 plf DIAPHRAGMS ANALYSIS (ASD METHOD) : Design Sumary Loading : Seis.(N-S)Wind(N-S)Govern Seis.(E-W)Wind (E-W)Govern Roof 72.8 63.4 Seismic 66.7 74.6 Wind For N-S Direction : Max. Diaphragm Shear @ Roof : Vn-s=wL/2B 30.63 plf < 180 plf OK USE : 15/32" APA(OR OSB) RATED SHEATHING EXP 1 WITH A MIN. PANEL INDEX OF 32/16. UNBOCKLED DIAPHRAGMS W/8d @ COMMON NAIL @ 6" O.C. B.N., 6" O.C. E.N., 12' O.C F.N. CHORD FORCE :93.82 SPICE W/ MINI (5)16d SINKER EACH SIDE OF SPLICE @ 8" O.C.(STANDARD CONSTRUCTIONS) For E-W Direction : Max. Diaphragm Shear @ Roof : Ve-w=wL/2B 43.07 plf < 180 plf OK USE : 15/32" APA(OR OSB) RATED SHEATHING EXP 1 WITH A MIN. PANEL INDEX OF 32/16. UNBOCKLED DIAPHRAGMS W/8d @ COMMON NAIL @ 6" O.C. B.N., 6" O.C. E.N., 12' O.C F.N. CHORD FORCE :163.22 SPICE W/ MINI (5)16d SINKER EACH SIDE OF SPLICE @ 8" O.C.(STANDARD CONSTRUCTIONS) Surface Location Cp q(psf)qGCp(psf)Net Pressure (psf) Windward Wall 11.34 Windward Roof -5.14 1.95 Leeward Roof -8.06 Leeward Wall -5.58 Side Walls -9.92 Location Net Pressure (psf) Surface Location Cp q(psf)qGCp(psf)Net Pressure (psf) Windward Wall 11.34 11.34 Leeward Wall -7.08 Side Walls -9.92 Location Net Pressure (psf) Windward Roof 0 to h/2 -12.75 -2.55 h/2 to h -12.75 -2.55 h to 2h -7.08 -2.55 >2h N/A N/A JOB NUMBER : 25655 PLAN: Story 1 Line :1 Redundancy(ρ) 1.3 Y Dir. Lateral loads : at B Max. Drag Force : 654 lb Use Drag Type A (See Shear wall Schedule) Alt. ST22 Total Wall Length : 18.75 ft Total Panel Length : 3.75 ft Net Length : 3.52 ft Shear Diaphragm : 64 plf Design Wall Shear : 319 plf Use ( 3 A35) or (3 LS50) Along Line Shear Panel or for Framing Clips Spacing See S.W. Schedule USE TYPE 2 ok Ratio Shear : 0.84 Max. Panel Deflection :1.806 " < 1.92 "ok Shear Wall Design A 3.75 8 2.13 Holdown & Deflection Check A 3.75 3.52 8 2450 2854 2450 2854 4X4 4X4 2 24" Holdown L. R. H/L Adjust Factor Actual (plf)Height (ft) Length (ft)SW Type Allowable (plf) 380 Uplift (lb) Down (lb)Holdown Uplift (lb) 0.938 319 Span (ft) Deep (ft) Wind (lbs)Seis. (lbs) (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code) SHEAR WALL DESIGN Deflection (in.)A.B.Spacing (in.) HDUE3 HDUE3 0.3225 23.25 24.00 1088 737 Sum :1196 737 Right 2 1Y_ROOF Post size Panel Length (ft) Net L (ft) Height (ft) Left Seis. Wall (lbs)108 Down (lb) Panel Span(ft) Seis. (lbs) Wind (lbs) From Line 2 Lateral Loads: 0% 0 0 Uplift Above 00 lbs DM = (4.0/1.0) X Ds X 1.4 = 0 1.75 4.75 8.5 11.5 13 15 18.7518.7518.7518.75 4.75 8.50000000000 A JOB NUMBER :25655 PLAN: Story 1 Line :2 Redundancy(ρ)1.3 Y Dir. Lateral loads : at B Max. Drag Force :865 lb Use Drag Type A (See Shear wall Schedule)Alt.ST22 Total Wall Length :18.75 ft Total Panel Length :5.00 ft Net Length :5.00 ft Shear Diaphragm :63 plf Design Wall Shear :236 plf Use ( 3 A35) or (3 LS50) Along Line Shear Panel or for Framing Clips Spacing See S.W. Schedule USE TYPE 2 ok Ratio Shear :0.62 Max. Panel Deflection :1.127 " <1.92 "ok Holdown & Deflection Check A 5.00 5.00 8 1753 2090 1753 2090 4X4 4X4 2 40" Uplift Above 00 lbs Span(ft)Seis. (lbs)Wind (lbs) From Line 2 Lateral Loads: 0%0 0 Post size Panel Length (ft) Net L (ft) Height (ft) Left Seis. Wall (lbs)92 Down (lb) 1Y_ROOF 23.25 24.00 1088 737 Sum :1180 737 Right Span (ft)Deep (ft)Wind (lbs)Seis. (lbs) (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code) SHEAR WALL DESIGN Deflection (in.)A.B.Spacing (in.) HDUE3 HDUE3 0.2013 Holdown L.R.Uplift (lb) Down (lb)Holdown Uplift (lb) M = (4.0/1.0) X s X 1.4 = 0 1.5 4.5 7.75 13.75 18.7518.7518.7518.7518.7518.75 13.75 18.750000000000 A ASCE Hazards Report Address: 2129 N Hathaway St Santa Ana, California 92705 Standard:ASCE/SEI 7-16 Latitude:33.764429 Risk Category:II Longitude:-117.854172 Soil Class:D - Default (see Section 11.4.3) Elevation:165.93904850886827 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Wed Nov 19 2025 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. https://ascehazardtool.org/Wed Nov 19 2025 SS : 1.315 S1 : 0.468 F a : 1.2 F v : N/A SMS : 1.578 SM1 : N/A SDS : 1.052 SD1 : N/A T L : 8 PGA : 0.552 PGA M : 0.662 F PGA : 1.2 Ie : 1 C v : 1.363 Seismic Site Soil Class: Results: Data Accessed: Date Source: D - Default (see Section 11.4.3) USGS Seismic Design Maps Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Wed Nov 19 2025 https://ascehazardtool.org/Wed Nov 19 2025 The ASCE Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE Hazard Tool. https://ascehazardtool.org/Wed Nov 19 2025 AREA TABULATION AREA SFR (E) SFR TOTALEXIST'G TO BE REMAIN EXIST'G TO BE CONVERTED 1,618 LOT AREA TOTAL LIVING LOT COVERAGE 6,000 1,618 399(E) 2 CAR GARAGE 399 2,017 34% TITLE 24 REQUIREMENTS WALLS:R-15 INSULATION GLASS WINDOWS:'U' FACTOR= 0.30 SHGC = 0.23 ROOF ATTIC:R-30 INSULATION DHW SYSTEM:(N) TANKLESS WTR/HTR UEF 0.95 200 KBTU's THE ADU SF / SFD SF IS FOR PARK & REC FEE PURPOSE ONLY. THE APPLICANT IS RESPONSIBLE FOR THE GIVEN "SFR SF" OF THE EXISTING PRIMARY RESIDENCE; BUILDING SAFETY STAFF ARE NOT RESPONSIBLE FOR THE ACCURACY OF THE GIVEN '"SFR SF" ADU/SFD= 399 S.F. / 1,618 S.F.= 0.25% RATIO PARK & REC FEE: 1 1 PROJECT DATA SITE ADDRESS OWNER LEGAL SCOPE OF PROPOSED WORK SHEET INDEX VICINITY MAP APPLICABLE CODES CONSTRUCTION NOTES CONSULTANTS SPECIAL INSPECTIONS REQUIRED TYPE OF CONSTRUCTION: OCCUPANCY GROUP: SPRINKLED: STORIES: 2129 N Hathaway St. Santa Ana, CA 92705 Mr. Julio Valdez (714) 679 - 5521 APN: 396 - 183 - 10 A-1 PROJECT DATA TUNG THANH VO 11122 BIXLER CIR, GARDEN GROVE, CA, 92840 PH (714) 928-2006 PROJECT DATA A-1 Araceli Maciel PH 714 / 285 1121 Revisions AA Revision Date By: Site: 21 2 9 N H a t h a w a y S t . Sa n t a A n a , C A 9 2 7 0 5 Owner: Sheet content: SHEET NUMBER: DRAWN: CHECKED: DATE: JOB NO: A.H. Mr. Julio Valdez (714) 679 - 5521 Engineer: P.O.Box 672 Orange California 92856 aramaci65@gmail.com 09/28/2025 AP N : 3 9 6 - 1 8 3 - 1 0 NT R : 5 9 1 0 B L K L o t : 4 8 R3 VB (E) SFR: NO 1 1 VERIFY ALL DIMENSIONS, DO NOT SCALE DRAWINGS. 2 IT SHALL BE THE RESPONSABILITY OF THE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS ON THE SITE PRIOR TO COMMENCING WORK AND IS TO NOTIFY THE OWNER AT ONCE UPON DISCOVERY OF ANY OMISSIONS OR CONFLICTS IN THE DRAWINGS 3 PREPARATION OF BUILDING SITE SHALL BE PER SECTION 3302 CBC (ALL STUMPS AND ROOTS SHALL BE REMOVED FROM THE SOIL TO A DEPTH OF AT LEAST 12 INCHES BELOW THE SURFACE OF THE GROUND TO BE OCCUPIED BY THE BUILDING) A-3 (E) SFR & GARAGE FLR PLAN A-4 (N) GARAGE CONV. TO A.D.U. FLR PLAN A-2 (E) SITE PLAN 399 S.F. (E) ATTACHED 2 CAR GARAGE TO BE CONVERTED INTO (N) A.D.U.= KITCHEN & LAUNDRY FACILITIES, LIV'G RM, DINE & SLEEP'G AREA WITH FULL BATHRM & WALK-IN CLOSET STRUCTURAL CONSULTANT ENERGY CONSULTANT A-5 ELEVATIONS FLOOD ZONE:"X" ZONING:R-1 APN: 396 - 183 - 10 UTILITIES NOTE UTILITIES WILL BE UNDERGROUNDED PER SAME SECTION 41.626 A.D.U. DISTANCE TO NEAREST BUS STOP 776 FT < 2,640 FT= 1 2 MILE 11 S.F. (E) LAUNDRY TO BE RELOCATED FROM GARAGE TO (E) INTERIOR SFR * TUNG THANH VO 11122 BIXLER CIR, GARDEN GROVE, CA, 92840 PH (714) 928-2006 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBSC) 2022 CALIFORNIA ENERGY CODE (CENC) AD-1 ARCHITECTURAL DETAILS GC-1 & GC-2 GREEN BUILDING STANDARDS CODE S-0 S-01 TYPICAL DETAILS S-1 FOUNDATION & FRAMING PLAN SD-1 STRUCTURAL DETAILS T24-0 MANDATORY MEASURES T24-1 ENERGY CALCULATIONS GENERAL STRUCTURAL NOTES U-1 UTILITY PLAN 2129 N Hathaway St (N) A.D.U. UNIT 2 FIRE SEVERITY HAZARD ZONE (FSHZ):NO 1 1 1 1 02/06/26 A.B. 02/06/26 PL 50.00' PL 1 2 0 . 0 0 ' 4 : 1 2 (E) WTR METER W M (E) SIDEWALK (E) YARDSCAPE AREA TABULATION AREA SFR (E) SFR TOTALEXIST'G TO BE REMAIN EXIST'G TO BE CONVERTED 1,618 LOT AREA TOTAL LIVING LOT COVERAGE 6,000 1,618 399(E) 2 CAR GARAGE 399 2,017 34% (E) GAS METER 399 S.F. (E) 2 CAR GARAGE CONV TO (N) A.D.U. TOTAL S.F.R. = 1,618 S.F. 4 : 124 : 12 4 : 1 2 N HATHAWAY ST E W S LANDSCAPE REAL PALM SMALL PINE CONCRETE GRASS FLOOR FINISHES (E) POOL (E) CONC. DRIVEWAY (E) GRASS (E) CONCRETE 42 ' - 2 " 19 ' - 0 " 36 ' - 0 " 5'-0"5'-0" 6'-10" 15 ' - 0 " 5' - 1 " 12'-3" 15 ' - 0 " 36 ' - 0 " 44 ' - 9 " (E) 6'-0'' HGT CONC. WALL. (E) 6'-0'' HGT CONC. WALL. 11'-0" 11 ' - 0 " 19 ' - 0 " 5'-0" (E) ELECTRIC POST 4 : 1 2 4 : 124 : 12 4 : 1 2 (E) 6'-0'' HGT CONC. WALL. S.F.R. 1 1,294 S.F. S.F.R. 2 158 S.F. S.F.R. 3 166 S.F. PL 50.00' PL 1 2 0 . 0 0 ' 4' - 0 " 6" THERE ARE NO EXISTING EASEMENTS ON SITE 6'-9" (E) DATE PALM TREE SMALL TREES SMALL TREES (E) 5 PINE TREES (E) SAGO PALM 5 GALS. SHRUBS (5) 1 GAL. SHRUBS (5) 1 GAL. SHRUBS (N) CONC. SIDEWALK 7' - 0 " 16 ' - 5 " 5'-0" 50'-0" 22 ' - 1 0 " 39 ' - 3 " 2 ' - 7 " 22 ' - 1 0 " (E) 6'-0'' HGT CONC. WALL. 29 ' - 9 " 1' - 5 " (N ) S E W E R E X T . 3" ø (E ) S E W E R 3" ø 3" ø (N) SEWER EXTENSION $ (N) ELECTRIC METER 100 AMP PER EDISON LOCATION (E) OVERHEAD SERVICE (E) ELECTRIC METER 1 1 1 1 1 1 1 (N) CONDENSER 1 1 (E) SEWER (N) SEWER EXTENSION FOR (N) A.D.U. 1 4 : 1 2 4 : 1 2 ATTIC VENT CALCULATIONS ATTIC AREA: _______________ S.F. ATTIC VENT REQUIRED= __________ SQ. IN. PROVIDE (4) _________________________________ GOOD FOR___________ SQ. IN. TOTAL ATTIC PROVIDED __________SQ. IN. 399 383 399/150x144= 383 SQ.IN. 12"x14" ATTIC VENT (GABLE END) 672 882 PROVIDE (3)__________________________________ GOOD FOR___________ SQ. IN. SLANT BACK ROOF VENTS (LOMANCO) 210 16" x 22" x 6" TH. 70 SQ. IN. EACH 3x70 SQ. IN. = 210 SQ. IN. ROOF PLAN A.D.U. (ROOF VENTS)SC=1/4"=1'-0" (E) CALIF. FRAM'G ROOF VENTS (TYP) 1 1 1 02/06/26 A.B. SITE PLAN Sc = 1/8"=1'-0" SITE PLAN A-2 Araceli Maciel PH 714 / 285 1121 Revisions AA Revision Date By: Site: 21 2 9 N H a t h a w a y S t . Sa n t a A n a , C A 9 2 7 0 5 Owner: Sheet content: SHEET NUMBER: DRAWN: CHECKED: DATE: JOB NO: A.H. Mr. Julio Valdez (714) 679 - 5521 Araceli Maciel Plan preparer: P.O.Box 672 Orange California 92856 aramaci65@gmail.com 09/28/2025 AP N : 3 9 6 - 1 8 3 - 1 0 NT R : 5 9 1 0 B L K L o t : 4 8 02/06/26 *WINDOW SCHEDULE SIZE FRAME OPERATION U-FACTOR MAX. SHGC MAX.REMARKS WIDTH x HEIGHT 3'-0" x 2'-0"VINYL # (N)=NEW (E)=EXIST'G (E)1 VINYL SLIDER4'-0" x 5'-0" 4'-0" x 4'-0"FIXVINYL *DOOR SCHEDULE SIZE FRAME OPERATION U-FACTOR MAX. SHGC MAX.REMARKS WIDTH x HEIGHT # (N)=NEW (E)=EXIST'G SWING 3'-0" x 6'-8"SWINGSOLID WOOD HOLLOW CORE SWINGHOLLOW CORE 2'-8" x 6'-8" 2'-6" x 6'-8" VINYL SLIDER6'-0" x 3'-0" (N)5 SWINGHOLLOW CORE W/ 2 VENTS2'-0" x 6'-0" VINYL SLIDER6'-0" x 3'-6" 6'-0" x 6'-8" (E)2 (E)3 (E)4 (E)5 SLIDER (E)1 (E)2 (E)3 (E)4 SLIDERVINYL (E ) 1 5 6 7 0 G A R A G E D R (E) 2 CAR GARAGE (E) BEDRM 1(E) BEDRM 2 (E) BEDRM 3 (E) BEDRM 4 (E) BA 1 (E) BA 2 (E) KITCH (E) LIV'G RM (E) ENTRY (E) FAMILIY ROOM (E) DINE IN RM W/H E W N S 1 1 2 2 2 2 3 4 4 5 11 2 33 3 3 2 2 4 5 5 (E) WASHING MACHINE (E) DRYER 40'-0" 19 ' - 0 " 42 ' - 2 " 21'-0" 40'-0" 6'-9"12'-3" 13'-5" 6'-4" 11 ' - 0 " 44 ' - 9 " 16 ' - 5 " 19 ' - 0 " 2' - 7 " 3 (E) LAUND. REF. FAU A-3 Araceli Maciel PH 714 / 285 1121 Revisions AA Revision Date By: Site: 21 2 9 N H a t h a w a y S t . Sa n t a A n a , C A 9 2 7 0 5 Owner: Sheet content: SHEET NUMBER: DRAWN: CHECKED: DATE: JOB NO: A.H. Mr. Julio Valdez (714) 679 - 5521 Araceli Maciel Plan preparer: P.O.Box 672 Orange California 92856 aramaci65@gmail.com 09/28/2025 AP N : 3 9 6 - 1 8 3 - 1 0 NT R : 5 9 1 0 B L K L o t : 4 8 (E) SFR & GARAGE FLR PLAN (E) S.F.R. FLOOR PLAN Sc = 1/4"=1'-0" 02/06/26 EXISTING WALLS TO REMAIN *WINDOW SCHEDULE SIZE FRAME OPERATION U-FACTOR MAX. SHGC MAX.REMARKS WIDTH x HEIGHT 4'-0" x 4'-0"VINYL # (N)=NEW (E)=EXIST'G (N)1 VINYL SLIDER(N)3 6'-0" x 4'-0"(N)2 DUAL GLAZE DUAL GLAZE TEMPERED VINYL *DOOR SCHEDULE SIZE FRAME OPERATION U-FACTOR MAX. SHGC MAX.REMARKS WIDTH x HEIGHT # (N)=NEW (E)=EXIST'G (N)2 SWING 3'-0" x 6'-8"SWINGSOLID WOOD(N)1 HOLLOW CORE2'-8" x 6'-8" DUAL GLAZE PROVIDE 2x8" SOLID WOOD (BACK W/C & SHOWER) PROVIDE 5 8 TYPE 'X' GYPSUM BOARD w/ MN 6d COOLER NAILS OR #6 DRYWALL SCREWS x 1 7 8 L. @ 6" o/c (FROM FLOOR TO ROOF SHT'G 3'-0" x 1'-0" SLIDER SLIDER EXISTING WALLS TO BE REMOVED NEW WALLS (N)3 SWINGHOLLOW CORE W&D STACK. (N) ENTRY SLOPE (N) BEDRM (N) BA (N) KITCH 4" Ø DRYER VENT (E) 2668 DR TO BE REMOVED & FINISH PROPERLY (E) 15670 GARAGE DR TO BE REMOVED & PROVIDE (N) 6'-0"w x 4'-0"L VINYL-SL (N) LIV'G RM 21'-0" 3'-0" 19 ' - 0 " 4' - 0 " 3'-0" 19 ' - 0 " 3' - 0 " 5' - 4 " 7' - 5 " 1 3 1 2'-0" x 6'-0" 2 REF. SH & POLE 2 VINYL SLIDER(N)4 DUAL GLAZE3'-0" x 3'-0" 4 3 2 2 3' - 5 " (N) DINE IN 3'-0"6'-8" TEMPERED 4'-10" 7'-10"13'-2" W/H (E) LAUND TO BE RELOCATED TO SFR A/C UNIT: MINI SPLIT (INTERIOR) CONDENSER W/ GRILL PROTECTOR & LOCK 1.2. 2 1 W&D STACK. (E) BEDRM 3 (E) BEDRM 4 (E) BA 1 (E) BA 2 (E) KITCH (E) ENTRY (E) FAMILIY ROOM W/H REF. WASHER & DRYER RELOCATED (N)4 SWINGHOLLOW CORE3'-0" x 6'-8" (N) 4" Ø DRYER VENT THRU ATTIC 2'-6" 3' - 1 " FAU CL R 8' - 6 " 2x4 STUDS @16" o/c w/ R-15 INSUL. (E) 2x4 COLLAR TIES @48" o/c w/ (N) 2x8 C.J.'s @ 24" o/c w/ R-30 INSUL. SECTION A SC=1/4"=1'-0" 2x4 STUDS @16" o/c w/ R-15 INSUL. (E) 2x6 R.R. @ 24" o/c 12 4 CL R 8' - 6 " (E) 2x6 CLG JST. @ 24" o/c (N) A.D.U.(E) BEDRM 4 (E) BEDRM 3 (E) 2x6 R.R. @ 24" o/c (E) 2x8 RD BD (E) RF RTR (E) CALIF. FRAM'G(N) 2x8 C.J. @ 24" o/c w/ R-30 INSUL. 2x4 STUDS @16" o/c w/ R-15 INSUL. EXT. STUCCO FINISH (E) SLAB ON GRADE: APPLY REDGARD PROOFING & CRACK PREVENTION MEMBRANE, CURE PRO-RED WATER PROOFING MEMBRANE 963, CBP 232 ICC- ESR #1463 SECTION B SC=1/4"=1'-0" A-4 B A-4 A 13 ' - 1 0 " CONCRETE SLAB PER PLAN: APPLY REDGARD PROOFING & CRACK PREVENTION MEMBRANE, CURE PRO-RED WATER PROOFING MEMBRANE 963, CBP 232 ICC- ESR #1463 (E) FOOT'G TO VERIFY AT FIELD. IF NOT, PROVIDE (N) 12" W. x 24" DP. w/ 2-#4 T&B (N) CONC. LANDING- 7 3/4" 1 AD1 2 AD1 24 " mi n . 30" min. PROVIDE 5/8" TYPE 'X' GYPSUM BOARD* & 3" THK. ROCKWOOL AFB SEMI-RIGID BATT. INSULATION STC 50 (FLR TO CEIL'G) *5/8" TYPE 'X' GYPSUM BOARD= ALONG THIS WALL FROM FLR TO ROOF SHEAT'G. APPLIED VERTICALLY OR HORIZONTALLY NAILED w/ 6d COOLER OR #6 DRYWALL SCREWS x 1 7/8" L. @ 6" o/c PROVIDE 5/8" TYPE 'X' GYPSUM BOARD* & 3" THK. ROCKWOOL AFB SEMI-RIGID BATT. INSULATION STC 50 (FLR TO CEIL'G) EXTERIOR STUCCO FINISH & UNDERSIDE O.H. *5/8" TYPE 'X' GYPSUM BOARD= ALONG THIS WALL FROM FLR TO ROOF SHEAT'G. APPLIED VERTICALLY OR HORIZONTALLY NAILED w/ 6d COOLER OR #6 DRYWALL SCREWS x 1 7/8" L. @ 6" o/c N S W E W.I.C. (N) 3'-0" HGT. VINYL FENCE w/ 4030 GATE DOOR 1 AD1 2 AD1 SD1 4 SD1 5 SD1 11 3 AD1 FLOOR PLAN KEY NOTES 3 AD1 6 AD1 10 SD1 0.3 0.23 0.3 0.23 0.3 0.23 0.3 0.23 1 1 1 1 TO HAVE (2) 12" x 12" VENTS (144 S.F.) TOTAL VENT= 288 SQ. IN. LAUNDRY DOOR2* * 1 3' - 2 " 1 1 1 3'-9" 1 02/06/26 A.B. A-4 Araceli Maciel PH 714 / 285 1121 Revisions AA Revision Date By: Site: 21 2 9 N H a t h a w a y S t . Sa n t a A n a , C A 9 2 7 0 5 Owner: Sheet content: SHEET NUMBER: DRAWN: CHECKED: DATE: JOB NO: A.H. Mr. Julio Valdez (714) 679 - 5521 Araceli Maciel Plan preparer: P.O.Box 672 Orange California 92856 aramaci65@gmail.com 09/28/2025 AP N : 3 9 6 - 1 8 3 - 1 0 NT R : 5 9 1 0 B L K L o t : 4 8 (N) GARAGE CONV TO A.D.U. (N) FLOOR PLAN GARAGE CONV. TO (N) A.D.U.Sc = 1/4"=1'-0" 02/06/26 (E) STUCCO G.I. WEEP SCREED STUCCO WALL FINISH TO MATCH EXISTING: PORTLAND CEMENT PLASTER (7 8" THICK 3-COAT STUCCO O/ MIN. 1-LAYER OF 60-MINUTE GRADE 'D' BUILDING PAPER ) USE 2- LAYERS OF BLD'G PAPER O/ PLYWOOD. 2. 3. 4. 1. 5. EXTERIOR ELEVATIONS KEY NOTES (E) 1X4 VERTICAL WOOD SIDING (E) ASPHALT SHINGLE ROOFING (E) SFR(N) ADU 12 4 12 4 2 3 5 5 3 2 12 4 12 4 12 4 5 (E) SFR (N) ADU 2 2 2 2 3 3 3 4 12 4 12 4 12 4 12 4 (E) SFR(N) ADU 5 2 2 3 3 3 4 44 1 12 ' - 1 " 8' - 0 " 6" T.O.P. R.L. R.L. R.L. 11 ' - 0 " 14 ' - 2 " 12 ' - 1 " 8' - 0 " 0' - 6 " T.O.P. R.L. R.L. 14 ' - 2 " 14 ' - 2 " R.L. 6" 8' - 0 " 12 ' - 1 " R.L. T.O.P. 6.12" X 14" ATTIC VENTS 6 6 (E) PLANTER ELEVATIONS A-5 02/06/26 Sc = 1/4"=1'-0"E L E V A T I O N S SOUTH WEST Araceli Maciel PH 714 / 285 1121 Revisions AA Revision Date By: Site: 21 2 9 N H a t h a w a y S t . Sa n t a A n a , C A 9 2 7 0 5 Owner: Sheet content: SHEET NUMBER: DRAWN: CHECKED: DATE: JOB NO: A.H. Mr. Julio Valdez (714) 679 - 5521 Araceli Maciel Plan preparer: P.O.Box 672 Orange California 92856 aramaci65@gmail.com 09/28/2025 AP N : 3 9 6 - 1 8 3 - 1 0 NT R : 5 9 1 0 B L K L o t : 4 8 NORTH 1 2 4 SC= 1" = 1'-0" SC= 1" = 1'-0" SC= 1" = 1'-0" SC= 1" = 1'-0"SC= 1" = 1'-0"SC= 1" = 1'-0" SC= 1" = 1'-0" SC= 1" = 1'-0" SC= 1" = 1'-0" SC= 1" = 1'-0" SC= 1" = 1'-0" SC= 1" = 1'-0" SC= 1" = 1'-0" 1-HOUR STC 50 TO 54 SC= 1" = 1'-0" 6 INTERIOR PARTITION 1-HOUR RATED EXTERIOR STUCCO WALL SC= 1" = 1'-0" WALL GRAB BAR BACKING DETAIL STUCCO UNDERSIDE DETAIL HINGED DR THRESHOLD STUCCO SCREED SC= 1" = 1'-0"5 3SC= 1" = 1'-0" SC= 1" = 1'-0"7OVERHANG 2' TO <5' DETAIL 1 1 1'-0" O.H. 4'-0" TO PROP. LINE NORTH 1 1 02/06/26 A.B. AD-1 Araceli Maciel PH 714 / 285 1121 Revisions ADA Revision Date By: Site: 21 2 9 N H a t h a w a y S t . Sa n t a A n a , C A 9 2 7 0 5 Owner: Sheet content: SHEET NUMBER: DRAWN: CHECKED: DATE: JOB NO: A.H. Mr. Julio Valdez (714) 679 - 5521 Araceli Maciel Plan preparer: P.O.Box 672 Orange California 92856 aramaci65@gmail.com 09/28/2025 AP N : 3 9 6 - 1 8 3 - 1 0 NT R : 5 9 1 0 B L K L o t : 4 8 ARCHITECTURAL DETAILS 02/06/26 1 1 1 CHAPTER 4 RESIDENTIAL MANDATORY MEASURES DIVISION 4.1 PLANNING AND DESIGN DIVISION 4.3 WATER EFFICIENCY AND CONSERVATION 4.406 ENHANCED DURABILITY AND REDUCED MAINTENANCE 4.406.1 RODENT PROOFING. Annular spaces around pipes, electric cables, conduits or other openings in sole/bottom plates at exterior walls shall be protected against the passage of rodents by closing such openings with cement mortar, concrete masonry or a similar method acceptable to the enforcing agency. 4.408 CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING 4.408.1 CONSTRUCTION WASTE MANAGEMENT. Recycle and/or salvage for reuse a minimum of 65 percent of the non-hazardous construction and demolition waste in accordance with either Section 4.408.2, 4.408.3 or 4.408.4, or meet a more stringent local construction and demolition waste management ordinance. Exceptions: 1. Excavated soil and land-clearing debris. 2. Alternate waste reduction methods developed by working with local agencies if diversion or recycle facilities capable of compliance with this item do not exist or are not located reasonably close to the jobsite. 3. The enforcing agency may make exceptions to the requirements of this section when isolated jobsites are located in areas beyond the haul boundaries of the diversion facility. 4.408.2 CONSTRUCTION WASTE MANAGEMENT PLAN. Submit a construction waste management plan in conformance with Items 1 through 5. The construction waste management plan shall be updated as necessary and shall be available during construction for examination by the enforcing agency. 1. Identify the construction and demolition waste materials to be diverted from disposal by recycling, reuse on the project or salvage for future use or sale. 2. Specify if construction and demolition waste materials will be sorted on-site (source separated) or bulk mixed (single stream). 3. Identify diversion facilities where the construction and demolition waste material collected will be taken. 4. Identify construction methods employed to reduce the amount of construction and demolition waste generated. 5. Specify that the amount of construction and demolition waste materials diverted shall be calculated by weight or volume, but not by both. 4.408.3 WASTE MANAGEMENT COMPANY. Utilize a waste management company, approved by the enforcing agency, which can provide verifiable documentation that the percentage of construction and demolition waste material diverted from the landfill complies with Section 4.408.1. Note: The owner or contractor may make the determination if the construction and demolition waste materials will be diverted by a waste management company. 4.408.4 WASTE STREAM REDUCTION ALTERNATIVE [LR]. Projects that generate a total combined weight of construction and demolition waste disposed of in landfills, which do not exceed 3.4 lbs./sq.ft. of the building area shall meet the minimum 65% construction waste reduction requirement in Section 4.408.1 4.408.4.1 WASTE STREAM REDUCTION ALTERNATIVE. Projects that generate a total combined weight of construction and demolition waste disposed of in landfills, which do not exceed 2 pounds per square foot of the building area, shall meet the minimum 65% construction waste reduction requirement in Section 4.408.1 4.408.5 DOCUMENTATION. Documentation shall be provided to the enforcing agency which demonstrates compliance with Section 4.408.2, items 1 through 5, Section 4.408.3 or Section 4.408.4.. Notes: 1. Sample forms found in "A Guide to the California Green Building Standards Code (Residential)" located at www.hcd.ca.gov/CALGreen.html may be used to assist in documenting compliance with this section. 2. Mixed construction and demolition debris (C & D) processors can be located at the California Department of Resources Recycling and Recovery (CalRecycle). 4.410 BUILDING MAINTENANCE AND OPERATION 4.410.1 OPERATION AND MAINTENANCE MANUAL. At the time of final inspection, a manual, compact disc, web-based reference or other media acceptable to the enforcing agency which includes all of the following shall be placed in the building: 1. Directions to the owner or occupant that the manual shall remain with the building throughout the life cycle of the structure. 2. Operation and maintenance instructions for the following: a. Equipment and appliances, including water-saving devices and systems, HVAC systems, photovoltaic systems, electric vehicle chargers, water-heating systems and other major appliances and equipment. b. Roof and yard drainage, including gutters and downspouts. c. Space conditioning systems, including condensers and air filters. d. Landscape irrigation systems. e. Water reuse systems. 3. Information from local utility, water and waste recovery providers on methods to further reduce resource consumption, including recycle programs and locations. 4. Public transportation and/or carpool options available in the area. 5. Educational material on the positive impacts of an interior relative humidity between 30-60 percent and what methods an occupant may use to maintain the relative humidity level in that range. 6. Information about water-conserving landscape and irrigation design and controllers which conserve water. 7. Instructions for maintaining gutters and downspouts and the importance of diverting water at least 5 feet away from the foundation. 8. Information on required routine maintenance measures, including, but not limited to, caulking, painting, grading around the building, etc. 9. Information about state solar energy and incentive programs available. 10. A copy of all special inspections verifications required by the enforcing agency or this code. 11. Information from the Department of Forestry and Fire Protection on maintenance of defensible space around residential structures. 12. Information and/or drawings identifying the location of grab bar reinforcements. 4.410.2 RECYCLING BY OCCUPANTS. Where 5 or more multifamily dwelling units are constructed on a building site, provide readily accessible area(s) that serves all buildings on the site and are identified for the depositing, storage and collection of non-hazardous materials for recycling, including (at a minimum) paper, corrugated cardboard, glass, plastics, organic waster, and metals, or meet a lawfully enacted local recycling ordinance, if more restrictive. Exception: Rural jurisdictions that meet and apply for the exemption in Public Resources Code Section 42649.82 (a)(2)(A) et seq. are note required to comply with the organic waste portion of this section. DIVISION 4.4 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY DIVISION 4.5 ENVIRONMENTAL QUALITY 4.303 INDOOR WATER USE 4.303.1 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS. Plumbing fixtures (water closets and urinals) and fittings (faucets and showerheads) shall comply with the sections 4.303.1.1, 4.303.1.2, 4.303.1.3, and 4.303.4.4. Note: All noncompliant plumbing fixtures in any residential real property shall be replaced with water-conserving plumbing fixtures. Plumbing fixture replacement is required prior to issuance of a certificate of final completion, certificate of occupancy, or final permit approval by the local building department. See Civil Code Section 1101.1, et seq., for the definition of a noncompliant plumbing fixture, types of residential buildings affected and other important enactment dates. 4.303.1.1 Water Closets. The effective flush volume of all water closets shall not exceed 1.28 gallons per flush. Tank-type water closets shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for Tank-type Toilets. Note: The effective flush volume of dual flush toilets is defined as the composite, average flush volume of two reduced flushes and one full flush. 4.303.1.2 Urinals. The effective flush volume of wall mounted urinals shall not exceed 0.125 gallons per flush. The effective flush volume of all other urinals shall not exceed 0.5 gallons per flush. 4.303.1.3 Showerheads. 4.303.1.3.1 Single Showerhead. Showerheads shall have a maximum flow rate of not more than 1.8 gallons per minute at 80 psi. Showerheads shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for Showerheads. 4.303.1.3.2 Multiple showerheads serving one shower. When a shower is served by more than one showerhead, the combined flow rate of all the showerheads and/or other shower outlets controlled by a single valve shall not exceed 1.8 gallons per minute at 80 psi, or the shower shall be designed to only allow one shower outlet to be in operation at a time. Note: A hand-held shower shall be considered a showerhead. 4.303.1.4 Faucets. 4.303.1.4.1 Residential Lavatory Faucets. The maximum flow rate of residential lavatory faucets shall not exceed 1.2 gallons per minute at 60 psi. The minimum flow rate of residential lavatory faucets shall not be less than 0.8 gallons per minute at 20 psi. 4.303.1.4.2 Lavatory Faucets in Common and Public Use Areas. The maximum flow rate of lavatory faucets installed in common and public use areas (outside of dwellings or sleeping units) in residential buildings shall not exceed 0.5 gallons per minute at 60 psi. 4.303.1.4.3 Metering Faucets. Metering faucets when installed in residential buildings shall not deliver more than 0.2 gallons per cycle. 4.303.1.4.4 Kitchen Faucets. The maximum flow rate of kitchen faucets shall not exceed 1.8 gallons per minute at 60 psi. Kitchen faucets may temporarily increase the flow above the maximum rate, but not to exceed 2.2 gallons per minute at 60 psi, and must default to a maximum flow rate of 1.8 gallons per minute at 60 psi. Note: Where complying faucets are unavailable, aerators or other means may be used to achieve reduction. 4.303.1.4.5 Pre-rinse spray valves. When installed, shall meet the requirements in the California Code of Regulations, Title 20 (Appliance Efficiency Regulations), Sections 1605.1 (h)(4) Table H-2, Section 1605.3 (h)(4)(A), and Section 1607 (d)(7) and shall be equipped with an integral automatic shutoff. FOR REFERENCE ONLY: The following table and code section have been reprinted from the California Code of Regulations, Title 20 (Appliance Efficiency Regulations),Section 1605.1 (h)(4) and Section 1605.3 (h)(4)(A). Title 20 Section 1605.3 (h)(4)(A): Commercial prerinse spray values manufactured on or after January 1, 2006, shall have a minimum spray force of not less than 4.0 ounces-force (ozf)[113 grams-force(gf)] 4.303.2 Submeters for multifamily buildings and dwelling units in mixed-used residential/commercial buildings. Submeters shall be installed to measure water usage of individual rental dwelling units in accordance with the California Plumbing Code. 4.303.3 Standards for plumbing fixtures and fittings. Plumbing fixtures and fittings shall be installed in accordance with the California Plumbing Code, and shall meet the applicable standards referenced in Table 1701.1 of the California Plumbing Code. TABLE - MAXIMUM FIXTURE WATER USE FIXTURE TYPE FLOW RATE SHOWER HEADS (RESIDENTIAL)1.8 GMP @ 80 PSI LAVATORY FAUCETS (RESIDENTIAL)MAX. 1.2 GPM @ 60 PSI MIN. 0.8 GPM @ 20 PSI LAVATORY FAUCETS IN COMMON & PUBLIC USE AREAS 0.5 GPM @ 60 PSI KITCHEN FAUCETS 1.8 GPM @ 60 PSI METERING FAUCETS 0.2 GAL/CYCLE WATER CLOSET 1.28 GAL/FLUSH URINALS 0.125 GAL/FLUSH 4.304 OUTDOOR WATER USE 4.304.1 OUTDOOR POTABLE WATER USE IN LANDSCAPE AREAS. Residential developments shall comply with a local water efficient landscape ordinance or the current California Department of Water Resources' Model Water Efficient Landscape Ordinance (MWELO), whichever is more stringent. NOTES: 1. The Model Water Efficient Landscape Ordinance (MWELO) is located in the California Code Regulations, Title 23, Chapter 2.7, Division 2. MWELO and supporting documents, including water budget calculator, are available at: https://www.water.ca.gov/ ABBREVIATION DEFINITIONS: HCD Department of Housing and Community Development BSC California Building Standards Commission DSA-SS Division of the State Architect, Structural Safety OSHPD Office of Statewide Health Planning and Development LR Low Rise HR High Rise AA Additions and Alterations N New NOTE: THIS TABLE COMPILES THE DATA IN SECTION 4.303.1, AND IS INCLUDED AS A CONVENIENCE FOR THE USER. SECTION 4.102 DEFINITIONS 4.102.1 DEFINITIONS The following terms are defined in Chapter 2 (and are included here for reference) FRENCH DRAIN. A trench, hole or other depressed area loosely filled with rock, gravel, fragments of brick or similar pervious material used to collect or channel drainage or runoff water. WATTLES. Wattles are used to reduce sediment in runoff. Wattles are often constructed of natural plant materials such as hay, straw or similar material shaped in the form of tubes and placed on a downflow slope. Wattles are also used for perimeter and inlet controls. 4.106 SITE DEVELOPMENT 4.106.1 GENERAL. Preservation and use of available natural resources shall be accomplished through evaluation and careful planning to minimize negative effects on the site and adjacent areas. Preservation of slopes, management of storm water drainage and erosion controls shall comply with this section. 4.106.2 STORM WATER DRAINAGE AND RETENTION DURING CONSTRUCTION. Projects which disturb less than one acre of soil and are not part of a larger common plan of development which in total disturbs one acre or more, shall manage storm water drainage during construction. In order to manage storm water drainage during construction, one or more of the following measures shall be implemented to prevent flooding of adjacent property, prevent erosion and retain soil runoff on the site. 1. Retention basins of sufficient size shall be utilized to retain storm water on the site. 2. Where storm water is conveyed to a public drainage system, collection point, gutter or similar disposal method, water shall be filtered by use of a barrier system, wattle or other method approved by the enforcing agency. 3. Compliance with a lawfully enacted storm water management ordinance. Note: Refer to the State Water Resources Control Board for projects which disturb one acre or more of soil, or are part of a larger common plan of development which in total disturbs one acre or more of soil. (Website: https://www.waterboards.ca.gov/water_issues/programs/stormwater/construction.html) 4.106.3 GRADING AND PAVING. Construction plans shall indicate how the site grading or drainage system will manage all surface water flows to keep water from entering buildings. Examples of methods to manage surface water include, but are not limited to, the following: 1. Swales 2. Water collection and disposal systems 3. French drains 4. Water retention gardens 5. Other water measures which keep surface water away from buildings and aid in groundwater recharge. Exception: Additions and alterations not altering the drainage path. 4.106.4 Electric vehicle (EV) charging for new construction. New construction shall comply with Section 4.106.4.1 or 4.106.4.2. Electric vehicle supply equipment (EVSE) shall comply with the California Electrical Code. Exceptions: 1. On a case-by-case basis, where the local enforcing agency has determined EV charging and infrastructure are not feasible based upon one or more of the following conditions: 1.1 Where there is no local utility power supply or the local utility is unable to supply adequate power. 1.2 Where there is evidence suitable to the local enforcing agency substantiating that additional local utility infrastructure design requirements, directly related to the implementation of Section 4.106.4, may adversely impact the construction cost of the project. 2. Accessory Dwelling Units (ADU) and Junior Accessory Dwelling Units (JADU) without additional parking facilities. 4.106.4.1 New one- and two-family dwellings and townhouses with attached private garages. For each dwelling unit, install a listed raceway to accommodate a dedicated 208/240-volt branch circuit. The raceway shall not be less than trade size 1 (nominal 1-inch inside diameter). The raceway shall originate at the main service or subpanel and shall terminate into a listed cabinet, box or other enclosure in close proximity to the proposed location of an EV charger. Raceways are required to be continuous at enclosed, inaccessible or concealed areas and spaces. The service panel and/or subpanel shall provide capacity to install a 40-ampere 208/240-volt minimum dedicated branch circuit and space(s) reserved to permit installation of a branch circuit overcurrent protective device. Exemption: A raceway is not required if a minimum 40-ampere 208/240-volt dedicated EV branch circuit is installed in close proximity to the proposed location of an EV charger at the time of original construction in accordance with the California Electrical Code. 4.106.4.1.1 Identification. The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging as "EV CAPABLE". The raceway termination location shall be permanently and visibly marked as "EV CAPABLE". CHAPTER 3 GREEN BUILDING SECTION 301 GENERAL 301.1 SCOPE. Buildings shall be designed to include the green building measures specified as mandatory in the application checklists contained in this code. Voluntary green building measures are also included in the application checklists and may be included in the design and construction of structures covered by this code, but are not required unless adopted by a city, county, or city and county as specified in Section 101.7. 301.1.1 Additions and alterations. [HCD] The mandatory provisions of Chapter 4 shall be applied to additions or alterations of existing residential buildings where the addition or alteration increases the building's conditioned area, volume, or size. The requirements shall apply only to and/or within the specific area of the addition or alteration. The mandatory provision of Section 4.106.4.2 may apply to additions or alterations of existing parking facilities or the addition of new parking facilities serving existing multifamily buildings. See Section 4.106.4.3 for application. Note: Repairs including, but not limited to, resurfacing, restriping and repairing or maintaining existing lighting fixtures are not considered alterations for the purpose of this section. Note: On and after January 1, 2014, residential buildings undergoing permitted alterations, additions, or improvements shall replace noncompliant plumbing fixtures with water-conserving plumbing fixtures. Plumbing fixture replacement is required prior to issuance of a certificate of final completion, certificate of occupancy or final permit approval by the local building department. See Civil Code Section 1101.1, et seq., for the definition of a noncompliant plumbing fixture, types of residential buildings affected and other important enactment dates. 301.2 LOW-RISE AND HIGH-RISE RESIDENTIAL BUILDINGS. [HCD] The provisions of individual sections of CALGreen may apply to either low-rise residential buildings high-rise residential buildings, or both. Individual sections will be designated by banners to indicate where the section applies specifically to low-rise only (LR) or high-rise only (HR). When the section applies to both low-rise and high-rise buildings, no banner will be used. SECTION 302 MIXED OCCUPANCY BUILDINGS 302.1 MIXED OCCUPANCY BUILDINGS. In mixed occupancy buildings, each portion of a building shall comply with the specific green building measures applicable to each specific occupancy. Exceptions: 1. [HCD] Accessory structures and accessory occupancies serving residential buildings shall comply with Chapter 4 and Appendix A4, as applicable. 2. [HCD] For purposes of CALGreen, live/work units, complying with Section 419 of the California Building Code, shall not be considered mixed occupancies. Live/Work units shall comply with Chapter 4 and Appendix A4, as applicable. 4.106.4.2 New multifamily dwellings, hotels and motels and new residential parking facilities. When parking is provided, parking spaces for new multifamily dwellings, hotels and motels shall meet the requirements of Section 4.106.4.2.2. Calculations for spaces shall be rounded up to the nearest whole number. A parking space served by electric vehicle supply equipment or designed as an EV charging space shall count as at least one standard automobile parking space only for the purpose of complying with any applicable minimum parking space requirements established by a local jurisdiction. See Vehicle Code Section 22511.2 for further details. 4.106.4.2.1 Reserved. 4.106.4.2.2 Multifamily dwellings, hotels and motels 1. EV ready parking spaces with receptacles. a. Hotels and motels. Forty (40) percent of the total number of parking spaces shall be equipped with low power Level 2 EV charging receptacles. b. Multifamily parking facilities. Forty (40) percent of the total number of parking spaces shall be equipped with low power Level 2 EV charging receptacles. EV charging receptacles required by this section shall be located in at least one assigned parking space per dwelling unit where assigned parking is provided but need not exceed forty (40) percent of the total number of assigned parking spaces provided on the site. Exception: Areas of parking facilities served by parking lifts, including but not limited to automated mechanical-access open parking garages as defined in the California Building Code; or parking facilities otherwise incapable of supporting electric vehicle charging. c. Receptacle power source. EV charging receptacles in multifamily parking facilities shall be provided with a dedicated branch circuit connected to the dwelling unit’s electrical panel, unless determined as infeasible by the project builder or designer and subject to concurrence of the local enforcing agency. Exception: Areas of parking facilities served by parking lifts, including but not limited to automated mechanical-access open parking garages as defined in the California Building Code; or parking facilities otherwise incapable of supporting electric vehicle charging. d. Receptacle configurations. 208/240V EV charging receptacles shall comply with one of the following configurations: 1. For 20-ampere receptacles, NEMA 6-20R 2. For 30-ampere receptacles, NEMA 14-30R 3. For 50-ampere receptacles, NEMA 14-50R 2. EV ready parking spaces with EV chargers. a. Hotels and motels. Ten (10) percent of the total number of parking spaces shall be equipped with Level 2 EV chargers. At least fifty (50) percent of the required EV chargers shall be equipped with J1772 connectors. b. Multifamily parking facilities. Ten (10) percent of the total number of parking spaces shall be equipped with Level 2 EV chargers. At least fifty (50) percent of the required EV chargers shall be equipped with J1772 connectors. Where common use parking or unassigned parking is provided, EV chargers shall be located in common use or unassigned parking areas and shall be available for use by all residents or guests. Where low power Level 2 EV charging receptacles or Level 2 EV chargers are installed beyond the minimum required, an automatic load management system (ALMS) may be used to reduce the maximum required electrical capacity to each space served by the ALMS. The electrical system and any on-site distribution transformers shall have sufficient capacity to deliver at least 3.3 kW simultaneously to each EV charging station (EVCS) served by the ALMS. The branch circuit shall have a minimum capacity of 40 amperes, and installed EV chargers shall have a capacity of not less than 30 amperes. 4.106.4.2.2.1 Electric vehicle charging stations (EVCS). Electric vehicle charging stations required by Section 4.106.4.2.2, Item 2, with EV chargers installed shall comply with Section 4.106.4.2.2.1.1. Exception: Electric vehicle charging stations serving public accommodations, public housing, motels and hotels shall not be required to comply with this section. See California Building Code, Chapter 11B, for applicable requirements. 4.106.4.2.2.1.1 Electric vehicle charging stations (EVCS) spaces with EV chargers installed; dimensions and location. EVCS spaces shall be designed to comply with the following: 1.The minimum length of each EVCS space shall be 18 feet (5486 mm). 2.The minimum width of each EVCS space shall be 9 feet (2743 mm). 3.One in every 25 EVCS spaces, but not less than one, shall also have an 8-foot (2438 mm) wide minimum aisle. A 5-foot (1524 mm) wide minimum aisle shall be permitted provided the minimum width of the EVCS space is 12 feet (3658 mm). Surface slope for this EVCS space and the aisle shall not exceed 1 unit vertical in 48 units horizontal (2.083 percent slope) in any direction. These EVCS spaces shall also comply with at least one of the following: a. The EVCS space shall be located adjacent to an accessible parking space meeting the requirements of the California Building Code, Chapter 11A, to allow use of the EV charger from the accessible parking space. b. The EVCS space shall be located on an accessible route, as defined in the California Building Code, Chapter 2, to the building. Exception: Electric vehicle charging stations designed and constructed in compliance with the California Building Code, Chapter 11B, are not required to comply with Section 4.106.4.2.2.1.1. 4.106.4.2.2.1.2 Accessible electric vehicle charging station spaces. In addition to the requirements in Section 4.106.4.2.2.1.1, all EV chargers, where installed, shall comply with the accessibility provisions for EV chargers in the California Building Code, Chapter 11B. EV ready spaces and EVCS in multifamily developments shall comply with California Building Code, Chapter 11A, Section 1109A. 4.106.4.2.3 Reserved. 4.106.4.2.4 Reserved. 4.106.4.2.5 Electric vehicle ready space signage. Electric vehicle ready spaces shall be identified by signage or pavement markings, in compliance with Caltrans Traffic Operations Policy Directive 13-01 (Zero Emission Vehicle Signs and Pavement Markings) or its successor(s). 4.106.4.3 Electric vehicle charging for additions and alterations of parking facilities serving existing multi-family buildings. Where new parking facilities are added, or electrical systems or lighting of existing parking facilities are added or altered and the work requires a building permit, ten (10) percent of the total number of parking spaces added or altered shall be EV capable spaces to support future Level 2 electric vehicle supply equipment. The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging purposes as “EV CAPABLE.” Notes: 1.Construction documents are intended to demonstrate the project’s capability and capacity for facilitating future EV charging. 2.There is no requirement for EV spaces to be constructed or available until EV chargers are installed for use. SECTION 4.501 GENERAL 4.501.1 Scope The provisions of this chapter shall outline means of reducing the quality of air contaminants that are odorous, irritating and/or harmful to the comfort and well being of a building's installers, occupants and neighbors. SECTION 4.502 DEFINITIONS 5.102.1 DEFINITIONS The following terms are defined in Chapter 2 (and are included here for reference) AGRIFIBER PRODUCTS. Agrifiber products include wheatboard, strawboard, panel substrates and door cores, not including furniture, fixtures and equipment (FF&E) not considered base building elements. COMPOSITE WOOD PRODUCTS. Composite wood products include hardwood plywood, particleboard and medium density fiberboard. "Composite wood products" does not include hardboard, structural plywood, structural panels, structural composite lumber, oriented strand board, glued laminated timber, prefabricated wood I-joists or finger-jointed lumber, all as specified in California Code of regulations (CCR), title 17, Section 93120.1. DIRECT-VENT APPLIANCE. A fuel-burning appliance with a sealed combustion system that draws all air for combustion from the outside atmosphere and discharges all flue gases to the outside atmosphere. DISCLAIMER:THIS DOCUMENT IS PROVIDED AND INTENDED TO BE USED AS A MEANS TO INDICATE AREAS OF COMPLIANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS (CALGREEN) CODE. DUE TO THE VARIABLES BETWEEN BUILDING DEPARTMENT JURISDICTIONS, THIS CHECKLIST IS TO BE USED ON AN INDIVIDUAL PROJECT BASIS AND MAY BE MODIFIED BY THE END USER TO MEET THOSE INDIVIDUAL NEEDS. THE END USER ASSUMES ALL RESPONSIBILITY ASSOCIATED WITH THE USE OF THIS DOCUMENT, INCLUDING VERIFICATION WITH THE FULL CODE. Y N/AYN/AYN/AYN/A RESPON. PARTY RESPON. PARTY RESPON. PARTY RESPON. PARTY 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE RESIDENTIAL MANDATORY MEASURES, SHEET 1 (July 2024 Supplement) Y = YES N/A =NOT APPLICABLE RESPON. PARTY =RESPONSIBLE PARTY (ie: ARCHITECT, ENGINEER, OWNER, CONTRACTOR, INSPECTOR ETC.) 4.201 GENERAL 4.201.1 SCOPE. For the purposes of mandatory energy efficiency standards in this code, the California Energy Commission will continue to adopt mandatory standards. DIVISION 4.2 ENERGY EFFICIENCY TABLE H-2 STANDARDS FOR COMMERCIAL PRE-RINSE SPRAY VALUES MANUFACTURED ON OR AFTER JANUARY 28, 2019 PRODUCT CLASS [spray force in ounce force (ozf)]MAXIMUM FLOW RATE (gpm) Product Class 1 (≤1.00 Product Class 2 (> 5.0 ozf and ≤1.20 Product Class 3 (> 8.0 ozf)1.28 ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü OWNER ü OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER ü OWNER OWNER OWNER GC-1 Araceli Maciel PH 714 / 285 1121 P.O.Box 672 Orange California 92856 aadrafting@msn.com Revisions Plan preparer: Revision Date By: Site: Owner: Sheet content: SHEET NUMBER: DRAWN: CHECKED: DATE: JOB NO: A.B. GREEN BUILDING STANDARDS CODE Araceli Maciel 21 2 9 N H a t h a w a y S t Sa n t a A n a , C A 9 2 7 0 5 AP N : 3 9 6 - 1 8 3 - 1 0 11/28/2025 Mr. Julio Valdez (714) 679-5521 N T R A C T 5 9 1 0 B L K L O T 4 8 12/03/25 MAXIMUM INCREMENTAL REACTIVITY (MIR). The maximum change in weight of ozone formed by adding a compound to the "Base Reactive Organic Gas (ROG) Mixture" per weight of compound added, expressed to hundredths of a gram (g O³/g ROC). Note: MIR values for individual compounds and hydrocarbon solvents are specified in CCR, Title 17, Sections 94700 and 94701. MOISTURE CONTENT. The weight of the water in wood expressed in percentage of the weight of the oven-dry wood. PRODUCT-WEIGHTED MIR (PWMIR). The sum of all weighted-MIR for all ingredients in a product subject to this article. The PWMIR is the total product reactivity expressed to hundredths of a gram of ozone formed per gram of product (excluding container and packaging). Note: PWMIR is calculated according to equations found in CCR, Title 17, Section 94521 (a). REACTIVE ORGANIC COMPOUND (ROC). Any compound that has the potential, once emitted, to contribute to ozone formation in the troposphere. VOC. A volatile organic compound (VOC) broadly defined as a chemical compound based on carbon chains or rings with vapor pressures greater than 0.1 millimeters of mercury at room temperature. These compounds typically contain hydrogen and may contain oxygen, nitrogen and other elements. See CCR Title 17, Section 94508(a). 4.503 FIREPLACES 4.503.1 GENERAL. Any installed gas fireplace shall be a direct-vent sealed-combustion type. Any installed woodstove or pellet stove shall comply with U.S. EPA New Source Performance Standards (NSPS) emission limits as applicable, and shall have a permanent label indicating they are certified to meet the emission limits. Woodstoves, pellet stoves and fireplaces shall also comply with applicable local ordinances. 4.504 POLLUTANT CONTROL 4.504.1 COVERING OF DUCT OPENINGS & PROTECTION OF MECHANICAL EQUIPMENT DURING CONSTRUCTION. At the time of rough installation, during storage on the construction site and until final startup of the heating, cooling and ventilating equipment, all duct and other related air distribution component openings shall be covered with tape, plastic, sheet metal or other methods acceptable to the enforcing agency to reduce the amount of water, dust or debris which may enter the system. 4.504.2 FINISH MATERIAL POLLUTANT CONTROL. Finish materials shall comply with this section. 4.504.2.1 Adhesives, Sealants and Caulks. Adhesives, sealant and caulks used on the project shall meet the requirements of the following standards unless more stringent local or regional air pollution or air quality management district rules apply: 1. Adhesives, adhesive bonding primers, adhesive primers, sealants, sealant primers and caulks shall comply with local or regional air pollution control or air quality management district rules where applicable or SCAQMD Rule 1168 VOC limits, as shown in Table 4.504.1 or 4.504.2, as applicable. Such products also shall comply with the Rule 1168 prohibition on the use of certain toxic compounds (chloroform, ethylene dichloride, methylene chloride, perchloroethylene and tricloroethylene), except for aerosol products, as specified in Subsection 2 below. 2. Aerosol adhesives, and smaller unit sizes of adhesives, and sealant or caulking compounds (in units of product, less packaging, which do not weigh more than 1 pound and do not consist of more than 16 fluid ounces) shall comply with statewide VOC standards and other requirements, including prohibitions on use of certain toxic compounds, of California Code of Regulations, Title 17, commencing with section 94507. 4.504.2.2 Paints and Coatings. Architectural paints and coatings shall comply with VOC limits in Table 1 of the ARB Architectural Suggested Control Measure, as shown in Table 4.504.3, unless more stringent local limits apply. The VOC content limit for coatings that do not meet the definitions for the specialty coatings categories listed in Table 4.504.3 shall be determined by classifying the coating as a Flat, Nonflat or Nonflat-High Gloss coating, based on its gloss, as defined in subsections 4.21, 4.36, and 4.37 of the 2007 California Air Resources Board, Suggested Control Measure, and the corresponding Flat, Nonflat or Nonflat-High Gloss VOC limit in Table 4.504.3 shall apply. 4.504.2.3 Aerosol Paints and Coatings. Aerosol paints and coatings shall meet the Product-weighted MIR Limits for ROC in Section 94522(a)(2) and other requirements, including prohibitions on use of certain toxic compounds and ozone depleting substances, in Sections 94522(e)(1) and (f)(1) of California Code of Regulations, Title 17, commencing with Section 94520; and in areas under the jurisdiction of the Bay Area Air Quality Management District additionally comply with the percent VOC by weight of product limits of Regulation 8, Rule 49. 4.504.2.4 Verification. Verification of compliance with this section shall be provided at the request of the enforcing agency. Documentation may include, but is not limited to, the following: 1. Manufacturer's product specification. 2. Field verification of on-site product containers. CHAPTER 7 INSTALLER & SPECIAL INSPECTOR QUALIFICATIONS 702 QUALIFICATIONS 702.1 INSTALLER TRAINING. HVAC system installers shall be trained and certified in the proper installation of HVAC systems including ducts and equipment by a nationally or regionally recognized training or certification program. Uncertified persons may perform HVAC installations when under the direct supervision and responsibility of a person trained and certified to install HVAC systems or contractor licensed to install HVAC systems. Examples of acceptable HVAC training and certification programs include but are not limited to the following: 1. State certified apprenticeship programs. 2. Public utility training programs. 3. Training programs sponsored by trade, labor or statewide energy consulting or verification organizations. 4. Programs sponsored by manufacturing organizations. 5. Other programs acceptable to the enforcing agency. 702.2 SPECIAL INSPECTION [HCD]. When required by the enforcing agency, the owner or the responsible entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition to other certifications or qualifications acceptable to the enforcing agency, the following certifications or education may be considered by the enforcing agency when evaluating the qualifications of a special inspector: 1. Certification by a national or regional green building program or standard publisher. 2. Certification by a statewide energy consulting or verification organization, such as HERS raters, building performance contractors, and home energy auditors. 3. Successful completion of a third party apprentice training program in the appropriate trade. 4. Other programs acceptable to the enforcing agency. Notes: 1. Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code. 2. HERS raters are special inspectors certified by the California Energy Commission (CEC) to rate homes in California according to the Home Energy Rating System (HERS). [BSC] When required by the enforcing agency, the owner or the responsible entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition, the special inspector shall have a certification from a recognized state, national or international association, as determined by the local agency. The area of certification shall be closely related to the primary job function, as determined by the local agency. Note: Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code. 703 VERIFICATIONS 703.1 DOCUMENTATION. Documentation used to show compliance with this code shall include but is not limited to, construction documents, plans, specifications, builder or installer certification, inspection reports, or other methods acceptable to the enforcing agency which demonstrate substantial conformance. When specific documentation or special inspection is necessary to verify compliance, that method of compliance will be specified in the appropriate section or identified applicable checklist. 4.505 INTERIOR MOISTURE CONTROL 4.505.1 General. Buildings shall meet or exceed the provisions of the California Building Standards Code. 4.505.2 CONCRETE SLAB FOUNDATIONS. Concrete slab foundations required to have a vapor retarder by California Building Code, Chapter 19, or concrete slab-on-ground floors required to have a vapor retarder by the California Residential Code, Chapter 5, shall also comply with this section. 4.505.2.1 Capillary break. A capillary break shall be installed in compliance with at least one of the following: 1. A 4-inch (101.6 mm) thick base of 1/2 inch (12.7mm) or larger clean aggregate shall be provided with a vapor barrier in direct contact with concrete and a concrete mix design, which will address bleeding, shrinkage, and curling, shall be used. For additional information, see American Concrete Institute, ACI 302.2R-06. 2. Other equivalent methods approved by the enforcing agency. 3. A slab design specified by a licensed design professional. 4.505.3 MOISTURE CONTENT OF BUILDING MATERIALS. Building materials with visible signs of water damage shall not be installed. Wall and floor framing shall not be enclosed when the framing members exceed 19 percent moisture content. Moisture content shall be verified in compliance with the following: 1. Moisture content shall be determined with either a probe-type or contact-type moisture meter.Equivalent moisture verification methods may be approved by the enforcing agency and shall satisfy requirements found in Section 101.8 of this code. 2. Moisture readings shall be taken at a point 2 feet (610 mm) to 4 feet (1219 mm) from the grade stamped end of each piece verified. 3. At least three random moisture readings shall be performed on wall and floor framing with documentation acceptable to the enforcing agency provided at the time of approval to enclose the wall and floor framing. Insulation products which are visibly wet or have a high moisture content shall be replaced or allowed to dry prior to enclosure in wall or floor cavities. Wet-applied insulation products shall follow the manufacturers' drying recommendations prior to enclosure. 4.506 INDOOR AIR QUALITY AND EXHAUST 4.506.1 Bathroom exhaust fans. Each bathroom shall be mechanically ventilated and shall comply with the following: 1. Fans shall be ENERGY STAR compliant and be ducted to terminate outside the building. 2. Unless functioning as a component of a whole house ventilation system, fans must be controlled by a humidity control. a. Humidity controls shall be capable of adjustment between a relative humidity range less than or equal to 50% to a maximum of 80%. A humidity control may utilize manual or automatic means of adjustment. b. A humidity control may be a separate component to the exhaust fan and is not required to be integral (i.e., built-in) Notes: 1. For the purposes of this section, a bathroom is a room which contains a bathtub, shower or tub/shower combination. 2. Lighting integral to bathroom exhaust fans shall comply with the California Energy Code. 4.507 ENVIRONMENTAL COMFORT 4.507.2 HEATING AND AIR-CONDITIONING SYSTEM DESIGN. Heating and air conditioning systems shall be sized, designed and have their equipment selected using the following methods: 1. The heat loss and heat gain is established according to ANSI/ACCA 2 Manual J - 2011 (Residential Load Calculation), ASHRAE handbooks or other equivalent design software or methods. 2. Duct systems are sized according to ANSI/ACCA 1 Manual D - 2014 (Residential Duct Systems), ASHRAE handbooks or other equivalent design software or methods. 3. Select heating and cooling equipment according to ANSI/ACCA 3 Manual S - 2014 (Residential Equipment Selection), or other equivalent design software or methods. Exception: Use of alternate design temperatures necessary to ensure the system functions are acceptable. TABLE 4.504.1 - ADHESIVE VOC LIMIT1,2 (Less Water and Less Exempt Compounds in Grams per Liter) ARCHITECTURAL APPLICATIONS VOC LIMIT INDOOR CARPET ADHESIVES 50 CARPET PAD ADHESIVES 50 OUTDOOR CARPET ADHESIVES 150 WOOD FLOORING ADHESIVES 100 RUBBER FLOOR ADHESIVES 60 SUBFLOOR ADHESIVES 50 CERAMIC TILE ADHESIVES 65 VCT & ASPHALT TILE ADHESIVES 50 DRYWALL & PANEL ADHESIVES 50 COVE BASE ADHESIVES 50 MULTIPURPOSE CONSTRUCTION ADHESIVE 70 STRUCTURAL GLAZING ADHESIVES 100 SINGLE-PLY ROOF MEMBRANE ADHESIVES 250 OTHER ADHESIVES NOT LISTED 50 SPECIALTY APPLICATIONS PVC WELDING 510 CPVC WELDING 490 ABS WELDING 325 PLASTIC CEMENT WELDING 250 ADHESIVE PRIMER FOR PLASTIC 550 CONTACT ADHESIVE 80 SPECIAL PURPOSE CONTACT ADHESIVE 250 STRUCTURAL WOOD MEMBER ADHESIVE 140 TOP & TRIM ADHESIVE 250 SUBSTRATE SPECIFIC APPLICATIONS METAL TO METAL 30 PLASTIC FOAMS 50 POROUS MATERIAL (EXCEPT WOOD)50 WOOD 30 FIBERGLASS 80 1. IF AN ADHESIVE IS USED TO BOND DISSIMILAR SUBSTRATES TOGETHER, THE ADHESIVE WITH THE HIGHEST VOC CONTENT SHALL BE ALLOWED. 2. FOR ADDITIONAL INFORMATION REGARDING METHODS TO MEASURE THE VOC CONTENT SPECIFIED IN THIS TABLE, SEE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168. TABLE 4.504.2 - SEALANT VOC LIMIT (Less Water and Less Exempt Compounds in Grams per Liter) SEALANTS VOC LIMIT ARCHITECTURAL 250 MARINE DECK 760 NONMEMBRANE ROOF 300 ROADWAY 250 SINGLE-PLY ROOF MEMBRANE 450 OTHER 420 SEALANT PRIMERS ARCHITECTURAL NON-POROUS 250 POROUS 775 MODIFIED BITUMINOUS 500 MARINE DECK 760 OTHER 750 TABLE 4.504.5 - FORMALDEHYDE LIMITS1 MAXIMUM FORMALDEHYDE EMISSIONS IN PARTS PER MILLION PRODUCT CURRENT LIMIT HARDWOOD PLYWOOD VENEER CORE 0.05 HARDWOOD PLYWOOD COMPOSITE CORE 0.05 PARTICLE BOARD 0.09 MEDIUM DENSITY FIBERBOARD 0.11 THIN MEDIUM DENSITY FIBERBOARD2 0.13 1. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIF. AIR RESOURCES BOARD, AIR TOXICS CONTROL MEASURE FOR COMPOSITE WOOD AS TESTED IN ACCORDANCE WITH ASTM E 1333. FOR ADDITIONAL INFORMATION, SEE CALIF. CODE OF REGULATIONS, TITLE 17, SECTIONS 93120 THROUGH 93120.12. 2. THIN MEDIUM DENSITY FIBERBOARD HAS A MAXIMUM THICKNESS OF 5/16" (8 MM). TABLE 4.504.3 - VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS2,3 GRAMS OF VOC PER LITER OF COATING, LESS WATER & LESS EXEMPT COMPOUNDS COATING CATEGORY VOC LIMIT FLAT COATINGS 50 NON-FLAT COATINGS 100 NONFLAT-HIGH GLOSS COATINGS 150 SPECIALTY COATINGS ALUMINUM ROOF COATINGS 400 BASEMENT SPECIALTY COATINGS 400 BITUMINOUS ROOF COATINGS 50 BITUMINOUS ROOF PRIMERS 350 BOND BREAKERS 350 CONCRETE CURING COMPOUNDS 350 CONCRETE/MASONRY SEALERS 100 DRIVEWAY SEALERS 50 DRY FOG COATINGS 150 FAUX FINISHING COATINGS 350 FIRE RESISTIVE COATINGS 350 FLOOR COATINGS 100 FORM-RELEASE COMPOUNDS 250 GRAPHIC ARTS COATINGS (SIGN PAINTS)500 HIGH TEMPERATURE COATINGS 420 INDUSTRIAL MAINTENANCE COATINGS 250 LOW SOLIDS COATINGS1 120 MAGNESITE CEMENT COATINGS 450 MASTIC TEXTURE COATINGS 100 METALLIC PIGMENTED COATINGS 500 MULTICOLOR COATINGS 250 PRETREATMENT WASH PRIMERS 420 PRIMERS, SEALERS, & UNDERCOATERS 100 REACTIVE PENETRATING SEALERS 350 RECYCLED COATINGS 250 ROOF COATINGS 50 RUST PREVENTATIVE COATINGS 250 SHELLACS CLEAR 730 OPAQUE 550 SPECIALTY PRIMERS, SEALERS & UNDERCOATERS 100 STAINS 250 STONE CONSOLIDANTS 450 SWIMMING POOL COATINGS 340 TRAFFIC MARKING COATINGS 100 TUB & TILE REFINISH COATINGS 420 WATERPROOFING MEMBRANES 250 WOOD COATINGS 275 WOOD PRESERVATIVES 350 ZINC-RICH PRIMERS 340 1. GRAMS OF VOC PER LITER OF COATING, INCLUDING WATER & EXEMPT COMPOUNDS 2. THE SPECIFIED LIMITS REMAIN IN EFFECT UNLESS REVISED LIMITS ARE LISTED IN SUBSEQUENT COLUMNS IN THE TABLE. 3. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR RESOURCES BOARD, ARCHITECTURAL COATINGS SUGGESTED CONTROL MEASURE, FEB. 1, 2008. MORE INFORMATION IS AVAILABLE FROM THE AIR RESOURCES BOARD. DIVISION 4.5 ENVIRONMENTAL QUALITY (continued) 4.504.3 CARPET SYSTEMS. All carpet installed in the building interior shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.3.1 Carpet cushion. All carpet cushion installed in the building interior shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.3.2 Carpet adhesive. All carpet adhesive shall meet the requirements of Table 4.504.1. 4.504.4 RESILIENT FLOORING SYSTEMS. Where resilient flooring is installed , at least 80% of floor area receiving resilient flooring shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health's website for certification programs and testing labs. hhtps://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.5 COMPOSITE WOOD PRODUCTS. Hardwood plywood, particleboard and medium density fiberboard composite wood products used on the interior or exterior of the buildings shall meet the requirements for formaldehyde as specified in ARB's Air Toxics Control Measure for Composite Wood (17 CCR 93120 et seq.), by or before the dates specified in those sections, as shown in Table 4.504.5 4.504.5.1 Documentation. Verification of compliance with this section shall be provided as requested by the enforcing agency. Documentation shall include at least one of the following: 1. Product certifications and specifications. 2. Chain of custody certifications. 3. Product labeled and invoiced as meeting the Composite Wood Products regulation (see CCR, Title 17, Section 93120, et seq.). 4. Exterior grade products marked as meeting the PS-1 or PS-2 standards of the Engineered Wood Association, the Australian AS/NZS 2269, European 636 3S standards, and Canadian CSA 0121, CSA 0151, CSA 0153 and CSA 0325 standards. 5. Other methods acceptable to the enforcing agency. DISCLAIMER:THIS DOCUMENT IS PROVIDED AND INTENDED TO BE USED AS A MEANS TO INDICATE AREAS OF COMPLIANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS (CALGREEN) CODE. DUE TO THE VARIABLES BETWEEN BUILDING DEPARTMENT JURISDICTIONS, THIS CHECKLIST IS TO BE USED ON AN INDIVIDUAL PROJECT BASIS AND MAY BE MODIFIED BY THE END USER TO MEET THOSE INDIVIDUAL NEEDS. THE END USER ASSUMES ALL RESPONSIBILITY ASSOCIATED WITH THE USE OF THIS DOCUMENT, INCLUDING VERIFICATION WITH THE FULL CODE. Y N/AYN/AYN/AYN/A RESPON. PARTY RESPON. PARTY RESPON. PARTY RESPON. PARTY 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE RESIDENTIAL MANDATORY MEASURES, SHEET 2 (July 2024 Supplement)Y = YES N/A =NOT APPLICABLE RESPON. PARTY =RESPONSIBLE PARTY (ie: ARCHITECT, ENGINEER, OWNER, CONTRACTOR, INSPECTOR ETC.) ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER OWNER GC-2 Araceli Maciel PH 714 / 285 1121 P.O.Box 672 Orange California 92856 aadrafting@msn.com Revisions Plan preparer: Revision Date By: Site: Owner: Sheet content: SHEET NUMBER: DRAWN: CHECKED: DATE: JOB NO: A.B. Araceli Maciel GREEN BUILDING STANDARDS CODE 21 2 9 N H a t h a w a y S t Sa n t a A n a , C A 9 2 7 0 5 AP N : 3 9 6 - 1 8 3 - 1 0 11/28/2025 Mr. Julio Valdez (714) 679-5521 N T R A C T 5 9 1 0 B L K L O T 4 8 12/03/25 UTILITY PLAN U-1 1 02/06/26 A.B. Araceli Maciel PH 714 / 285 1121 Revisions Revision Date By: Site: 21 2 9 N H a t h a w a y S t . Sa n t a A n a , C A 9 2 7 0 5 Owner: Sheet content: SHEET NUMBER: DRAWN: CHECKED: DATE: JOB NO: A.H. Mr. Julio Valdez (714) 679 - 5521 Araceli Maciel Plan preparer: P.O.Box 672 Orange California 92856 aramaci65@gmail.com 09/28/2025 AP N : 3 9 6 - 1 8 3 - 1 0 NT R : 5 9 1 0 B L K L o t : 4 8 02/06/26 SLOPE REF. SH & POLE W/H 2 1 (E) BEDRM 3 (E) BEDRM 4 (E) BA 1 (E) BA 2 (E) KITCH (E) ENTRY (E) FAMILIY ROOM W/H REF. WASHER & DRYER RELOCATED (N) 4" Ø DRYER VENT THRU ATTIC FAU (N) CONC. LANDING- 7 3/4" 1 AD1 2 AD1 24 " mi n . 30" min. N S W E UNDER COUNTER 1/ 4 " SL O P E 1/ 4 " SL O P E 1/4" SLOPE 1/4" SLOPE 110v UTILITY FLOOR PLAN SC=1/4"=1'-0" UTILITY LEGEND FOOTNOTES a.ALL OUTLETS ARE TO BE AFCI WITH NO EXCEPTIONS b.ALL LIGHTS ARE HIGH EFFICACY WITH NO EXCEPTIONS c.ALL RECEPTACLES REQUIRED GFCI SHALL BE COMBINATION OF AFCI, GFCI (CEC 210.52(E)(1)) d.ALL NEW RECEPTACLES IN BATHROOM WET AREAS OR OVER THE COUNTER, SHALL BE COMBINATION OF GFCI and AFCI PER 2019 CODE REQUIREMENTS. e.EXTERIOR RECEPTACLES REQUIRED FOR DECK/PORCH SHALL BE ON AFCI, GFCI, AND W.P. f.MINIMUM LIGHTING IS REQUIRED FOR LANDING, STEPS, DECK PER CODE, 1 FOOT CANDLE. LOCATE LIGHTING WITH SENSOR OR TIME SCHEDULE SWITCH PER CODE. ELECTRICAL NOTES a.WHERE A COMPARTMENT OR SPACE FOR DOMESTIC CLOTHES DRYER IS PROVIDED, NOT LESS THAN A 4 INCH DIAMETER MOISTURE EXHAUST DUCT OF APPROVED MATERIAL SHALL BE INSTALLED. [CMC 504.3.1] b.MOISTURE EXHAUST DUCTS FOR THE DRYER SHALL TERMINATE ON THE OUTSIDE OF THE BUILDING AND SHALL BE EQUIPPED WITH A BACKDRAFT DUMPER. [CMC 504.3] c.WHERE A CLOSET IS DESIGNED FOR INSTALLATION OF A CLOTHES DRYER, AN OPENING OF NOT LESS THAN 100 SQUARE INCHES FOR MAKEUP AIR SHALL BE PROVIDED IN DOOR OR BY OTHER APPROVED MEANS. [CMC 504.3.1] d.SHOW ON THE PLANS THAT ENVIRONMENTAL AIR DUCT EXHAUST FROM CLOTHES DRYER SHALL TERMINATE NOT LESS THAN 3 FEET FROM A PROPERTY LINE AND 3 FEET FROM OPENINGS IN ANY DIRECTION FROM OPENINGS INTO THE BUILDING. [CMC 504.5] e.A DOMESTIC CLOTHES DRYER DUCT SHALL BE OF METAL AND A MINIMUM OF 4 INCHES IN DIAMETER. THE EXHAUST DUCT SHALL NOT EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGTH OF 14 FEET, INCLUDING TWO 90 DEGREE ELBOWS. TWO FEET SHALL BE DEDUCTED FOR EACH 90 DEGREE ELBOW IN EXCESS OF TWO. (CMC 504.2.2.1) f.LAUNDRY VENTILATION EXHAUST SHALL TERMINATE AT LEAST 3 FEET FROM THE PROPERTY LINE AND 3 FEET FROM OPENINGS INTO ANY BUILDINGS. (CMC 504.5) DRYER NOTES: RECESSED DOWNLIGHT LUMINAIRES IN CEILINGS. LUMINAIRES RECESSED INTO CEILINGS SHALL MEET ALL OF THE FOLLOWING REQUIREMENTS: a.BE LISTED, AS DEFINED IN SECTION 100.1, FOR ZERO CLEARANCE INSULATION CONTACT (IC) BY UNDERWRITERS LABORATORIES OR OTHER NATIONALLY RECOGNIZED TESTING/RATING LABORATORY b.HAVE A LABEL THAT CERTIFIES THE LUMINAIRE IS AIRTIGHT WITH AIR LEAKAGE LESS THAN 2.0 CFM AT 75 PASCALS WHEN TESTED IN ACCORDANCE WITH ASTM E283. AN EXHAUST FAN HOUSING SHALL NOT BE REQUIRED TO BE CERTIFIED AIRTIGHT c.BE SEALED WITH A GASKET OR CAULK BETWEEN THE LUMINAIRE HOUSING AND CEILING, AND HAVE ALL AIR LEAK PATHS BETWEEN CONDITIONED AND UNCONDITIONED SPACES SEALED WITH A GASKET OR CAULK d.SHALL NOT CONTAIN SCREW BASE SOCKETS RECESSED LIGHT NOTES SMOKE ALARM NOTES a.SMOKE ALARM: IN EACH SLEEPING ROOM b.SMOKE ALARM & CARBON MONOXIDE ALARM: i. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. ii. ON EACH FLOOR INCLUDING BASEMENTS AND HABITABLE ATTICS. c.SPECIFY UL217 FOR SMOKE DETECTOR AND UL2034/2075 FOR CARBON MONOXIDE DETECTOR ON PLAN. d.SMOKE ALARMS AND SMOKE DETECTORS SHALL NOT BE INSTALLED WITHIN A 36 IN. (910 mm) HORIZONTAL PATH FROM THE SUPPLY REGISTERS OF A FORCED AIR HEATING OR COOLING SYSTEM AND SHALL BE INSTALLED OUTSIDE OF THE DIRECT AIRFLOW FROM THOSE REGISTERS. A COMPLIANT DIMMER UNLESS THEY ARE CONTROLLED BY A VACANCY SENSOR OR AN OCCUPANCY SENSOR. THE COMBINED USE OF NEMA SSL-7A-COMPLIANT DIMMER WITH LED LUMINAIRES CAN ENSURE FLICKER FREE OPERATION WHEN THE LUMINAIRE IS DIMMED. a.WATER CLOSETS 1.28 gallons/flush b.SHOWERHEADS - SINGLE 1.8 gpm @ 80 psi c.SHOWERHEADS - MULTIPLE 1.8 gpm @ 80 psi combined d.LAVATORY FAUCETS 1.2 gpm @ 60 psi e.KITCHEN FAUCETS 1.8 gpm @60 psi ALL PLUMBING FIXTURES AND FITTINGS SHALL COMPLY WITH THE FOLLOWING MAX. FLOWRATES: # SHOWER NOTES a.SHOWER COMPARTMENTS SHALL BE NOT LESS THAN 1,024 SQ. IN., SHALL HAVE A MINIMUM CEILING HEIGHT OF 6'-8" AND ALSO BE CAPABLE OF ENCOMPASSING A 30" DIAMETER CIRCLE AT THE SHOWERHEAD. b.SHOWER SHALL BE PROVIDED WITH MIXING VALVE THAT WILL PROVIDE SCALD AND THERMAL SHOCK PROTECTION IN ACCORDANCE WITH ASSE 1016 OR ASME A112.18.1/CSA B125.1. c.SHOWER THRESHOLD SHALL BE NO LESS THAN 2 INCHES ABOVE SHOWER DRAIN. THE FINISHED FLOOR OF THE RECEPTOR SHALL SLOPE UNIFORMLY FROM THE SIDES TOWARDS THE DRAIN NOT LESS THAN 1/4" PER FOOT AND NOT MORE THAN 1/2" PER FOOT. d.GLAZING IN ENCLOSURE FOR OR WALLS FACING HOT TUBS, BATHTUBS, SHOWERS WHIRL-POOLS, SAUNAS, STEAM ROOMS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60" ABOVE THE ANY STANDING SURFACE. a.A 120V ELECTRICAL RECEPTACLE THAT IS WITHIN 3 FEET FROM THE WATER HEATER b.A CATEGORY III OR IV VENT, OR A TYPE B VENT WITH STRAIGHT PIPE. c.CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES HIGHER THAN THE FINISH SURFACE BELOW. d.A GAS SUPPLY LINE WITH AVAILABLE CAPACITY FOR NOT LESS THAN A 200,000 BTU/HR SYSTEM".) e.THE PIPING FOR ALL SPACE CONDITIONING AND SERVICE WATER HEATING SYSTEMS SHALL BE INSULATED IN ACCORDANCE WITH TABLE 120.3-A. ALL WATER HEATER INSTALLATION LOCATIONS, REGARDLESS OF PROPOSE WATER HEATING SYSTEM, SHALL HAVE:a.CONTROL VALVES AND SHOWERHEADS SHALL BE LOCATED ON THE SIDEWALL OF SHOWER COMPARTMENTS OR OTHERWISE ARRANGED SO THAT THE SHOWERHEAD DOES NOT DISCHARGE DIRECTLY AT THE ENTRANCE TO THE COMPARTMENT SO THAT THE BATHER CAN ADJUST THE VALVES PRIOR TO STEPPING INTO THE SHOWER SPRAY. SHOWER CONTROL b. SHOWER SHALL BE PROVIDED WITH MIXING VALVE THAT WILL PROVIDE SCALD AND THERMAL SHOCK PROTECTION. HOT WATER PIPING NOTE a. PROVIDE INSULATION OF DOMESTIC HOT WATER PIPING. 110v 9v WHOLE HOUSE IAQ FAN NOTE THE WHOLE-BUILDING VENTILATION EXHAUST FAN WILL OPERATE CONTINUOUSLY AND IS REQUIRED TO BE RATED FOR SOUND AT A MAXIMUM OF 1 SONE. THIS EXHAUST FAN CAN BE CONTROLLED BY A STANDARD ON/OFF SWITCH BUT THE SWITCH MUST BE LABELED CLEARLY DISPLAYING THE FOLLOWING TEXT, OR EQUIVALENT: "THIS SWITCH CONTROLS THE INDOOR AIR QUALITY VENTILATION FOR THE HOME. LEAVE SWITCH IN THE 'ON' POSITION AT ALL TIMES UNLESS THE OUTDOOR AIR QUALITY IS VERY POOR". CFM REQUIRED= 44 HEAT PUMP SPACE HEATER READY SYSTEMS USING GAS OR PROPANE FURNACE TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE THE FOLLOWING: 1. A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FT. FROM THE FURNACE AND ACCESSIBLE TO THE FURNACE WITH NO OBSTRUCTIONS. THE BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT 30 AMPS MINIMUM. THE BLANK COVER SHALL BE IDENTIFIED AS "240 V READY" HEAT PUMP WATER NOTE THE HPWH WILL BE INSTALLED ACCORDING TO MANUFACTURER'S REQUIREMENTS PER SHEET U-2. W/H b a e d PROVIDE 2x8" SOLID WOOD (BACK W/C & SHOWER) PROVIDE 5 8 TYPE 'X' GYPSUM BOARD w/ MN 6d COOLER NAILS OR #6 DRYWALL SCREWS x 1 7 8 L. @ 6" o/c (FROM FLOOR TO ROOF SHT'G (E) BEDRM 1(E) BEDRM 2 (E) LIV'G RM (E) DINE IN RM 9v 9v 9v 9v 9v 9v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Ø STEEL BOLTS EMBEDDED 7" @ 48" O.C. INTO THE FOUNDATION WITH MINIMUM 3" S.Q x 0.25" PLATE WASHER FOR THE ANCHOR BOLTS. MINIMUM EDGE DISTANCE 1-7/8" AND WITHIN 12" OF EACH END OF EACH PLATE. 2.ALL SHEAR HARDWARE AND ANCHOR BOLTS W/ NON-STANDARD SPACING ARE TO BE FIXED IN PLACE FOR THE FOUNDATION INSPECTION. 3.FASTENERS FOR PRESERVATIVE-TREATED SHALL BE NOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. 4.A PROPERLY SIZED NUT AND WASHER SHALL BE TIGHTENED ON EACH ANCHOR BOLT TO THE PLATE. 5.HOLDOWN CONNECTORS BOLTS HOLES SHALL NOT BE MORE THAN 1/16" OVERSIZED AT THE CONNECTOR OF THE HOLD DOWN TO THE POST. 6.HOLD DOWN CONNECTORS SHALL BE RE-TIGHTENED JUST PRIOR TO COVERING THE WALL FRAMING. 7.ALL FOUNDATIONS SHALL BEAR UPON LIKE MATERIAL. 8.FINAL SOILS / AS-GRADED REPORT WILL BE REQUIRED AT FOUNDATION / SLAB INSPECTION. NAILING SCHEDULE: (TABLE R602.3(1) W/ FOOT NOTES 2022 CRC) ITEM DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENERa, b, c SPACING AND LOCATION 1 Blocking between ceiling joists or rafters to top plate 4-8d box (2 1/2″ × 0.113″) or 3-8d common (2 1/2″ × 0.131″); or 3-10d box (3″ × 0.128″); or 3-3″ × 0.131″ nails Toe nail 2 Ceiling joists to top plate 4-8d box (2 1/2″ × 0.113″); or 3-8d common 2 1/2″ × 0.131″); or 3-10d box (3″ × 0.128″); or 3-3″ × 0.131″ nails Per joist, toe nail 3 Ceiling joist not attached to parallel rafter, laps over partitions [see Sections R802.3.1, R802.3.2 and Table R802.5.1(9)] 4-10d box (3″ × 0.128″); or 3-16d common (3 1/2″ × 0.162″); or 4-3″ × 0.131″ nails Face nail 4 Ceiling joist attached to parallel rafter (heel joint) [see Sections R802.3.1 and R802.3.2 and Table R802.5.1(9)] Table R802.5.1(9)Face nail 5 Collar tie to rafter, face nail or 11/4″ × 20 ga. ridge strap to rafter 4-10d box (3″ × 0.128″); or 3-10d common (3″ × 0.148″); or 4-3″ × 0.131″ nails Face nail each rafter 6 Rafter or roof truss to plate 3-16d box nails (3 1/2″ × 0.135″); or 3-10d common nails (3″ × 0.148″); or 4-10d box (3″ × 0.128″); or 4-3″ × 0.131″ nails 2 toe nails on one side and 1 toe nail on opposite side of each rafter or truss 7 Roof rafters to ridge, valley or hip rafters or roof rafter to minimum 2″ ridge beam 4-16d (3 1/2″ × 0.135″); or 3-10d common (3 1/2″ × 0.148″); or 4-10d box (3″ × 0.128″); or 4-3″ × 0.131″ nails Toe nail 3-16d box 3 1/2″ × 0.135″); or 2-16d common (3 1/2″ × 0.162″); or 3-10d box (3″ × 0.128″); or 3-3″ × 0.131″ nails End nail WALL 8 Stud to stud (not at braced wall panels) 16d common (3 1/2″ × 0.162″)24″ o.c. face nail 10d box (3″ × 0.128″); or 3″ × 0.131″ nails 16″ o.c. face nail 9 Stud to stud and abutting studs at intersecting wall corners (at braced wall panels) 4-10d box (3″ × 0.128″); or 3-16d common (3 1/2″ × 0.162″); or 4-3″ × 0.131″ nails 12″ o.c. face nail 16d common (3 1/2″ × 0.162″)16″ o.c. face nail 10 Built-up header (2″ to 2″ header with 1/2″ spacer) 16d common (3 1/2″ × 0.162″)16″ o.c. each edge face nail 16d box (3 1/2″ × 0.135″)12″ o.c. each edge face nail 11 Continuous header to stud 5-8d box (2 1/2″ × 0.113″); or 4-8d common (2 1/2″ × 0.131″); or 4-10d box (3″ × 0.128″) Toe nail 12 Top plate to top plate 16d common (3 1/2″ × 0.162″)16″ o.c. face nail 10d box (3″ × 0.128″); or 3″ × 0.131″ nails 12″ o.c. face nail 13 Double top plate splice for SDCs A-D2 with seismic braced wall line spacing < 25' 8-16d common (3 1/2″ × 0.162″); or 12-16d box (3 1/2″ × 0.135″); or 12-10d box (3″ × 0.128″); or 12-3″ × 0.131″ nails Face nail on each side of end joint (minimum 24″ lap splice length each side of end joint)Double top plate splice SDCs D0, D1, or D2; and braced wall line spacing ≥ 25' 12-16d (3 1/2″ × 0.135″) 14 Bottom plate to joist, rim joist, band joist or blocking (not at braced wall panels) 16d common (3 1/2″ × 0.162″)16″ o.c. face nail 16d box (3 1/2″ × 0.135″); or 3″ × 0.131″ nails 12″ o.c. face nail 15 Bottom plate to joist, rim joist, band joist or blocking (at braced wall panel) 3-16d box (3 1/2″ × 0.135″); or 2-16d common (3 1/2″ × 0.162″); or 4-3″ × 0.131″ nails 3 each 16″ o.c. face nail 2 each 16″ o.c. face nail 4 each 16″ o.c. face nail 16 Top or bottom plate to stud 4-8d box (2 1/2″ × 0.113″); or 3-16d box (3 1/2″ × 0.135″); or 4-8d common (2 1/2″ × 0.131″); or 4-10d box (3″ × 0.128″); or 4-3″ × 0.131″ nails Toe nail 3-16d box (3 1/2″ × 0.135″); or 2-16d common (3 1/2″ × 0.162″); or 3-10d box (3″ × 0.128″); or 3-3″ × 0.131″ nails End nail 17 Top plates, laps at corners and intersections 3-10d box (3″ × 0.128″); or 2-16d common (3 1/2″ × 0.162″); or 3-3″ × 0.131″ nails Face nail 18 1″ brace to each stud and plate 3-8d box (2 1/2″ × 0.113″); or 2-8d common (2 1/2″ × 0.131″); or 2-10d box (3″ × 0.128″); or 2 staples 1 3/4″ Face nail 19 1″ × 6″ sheathing to each bearing 3-8d box (2 1/2″ × 0.113″); or 2-8d common (2 1/2″ × 0.131″); or 2-10d box (3″ × 0.128″); or 2 staples, 1″ crown, 16 ga., 1 3/4″ long Face nail 20 1″ × 8″ and wider sheathing to each bearing 3-8d box (2 1/2″ × 0.113″); or 3-8d common (2 1/2″ × 0.131″); or 3-10d box (3″ × 0.128″); or 3 staples, 1″ crown, 16 ga., 1 3/4″ long Face nailWider than 1″ × 8″ 4-8d box (2 1/2″ × 0.113″); 3-8d common (2 1/2″ × 0.131″); or 3-10d box (3″ × 0.128″); or 4 staples, 1″ crown, 16 ga., 1 3/4″ long FLOOR 21 Joist to sill, top plate or girder 4-8d box (2 1/2″ × 0.113″); or 3-8d common (2 1/2″ × 0.131″); or 3-10d box (3″ × 0.128″); or 3-3″ × 0.131″ nails Toe nail 22 Rim joist, band joist or blocking to sill or top plate (roof applications also) 8d box (2 1/2″ × 0.113″)4″ o.c. toe nail 8d common (2 1/2″ × 0.131″); or 10d box (3″ × 0.128″); or 3″ × 0.131″ nails 6″ o.c. toe nail 23 1″ × 6″ subfloor or less to each joist 3-8d box (2 1/2″ × 0.113″); or 2-8d common (2 1/2″ × 0.131″); or 3-10d box (3″ × 0.128″); or 2 staples, 1″ crown, 16 ga., 1 3/4″ long Face nail 24 2″ subfloor to joist or girder 3-16d box (3 1/2″ × 0.135″); or 2-16d common (3 1/2″ × 0.162″)Blind and face nail 25 2″ planks (plank & beam—floor & roof) 3-16d box (3 1/2″ × 0.135″); or 2-16d common (3 1/2″ × 0.162″) At each bearing, face nail 26 Band or rim joist to joist 3-16d common (3 1/2″ × 0.162″) 4-10 box (3″ × 0.128″), or 4-3″ × 0.131″ nails; or 4-3″ × 14 ga. staples, 7/16″ crown End nail 27 Built-up girders and beams, 2-inch lumber layers 20d common (4″ × 0.192″) Nail each layer as follows: 32″ o.c. at top and bottom and staggered. 10d box (3″ × 0.128″); or 3″ × 0.131″ nails 24″ o.c. face nail at top and bottom staggered on opposite sides And: 2-20d common (4″ × 0.192″); or 3-10d box (3″ × 0.128″); or 3-3″ × 0.131″ nails Face nail at ends and at each splice 28 Ledger strip supporting joists or rafters 4-16d box (3 1/2″ × 0.135″); or 3-16d common (3 1/2″ × 0.162″); or 4-10d box (3″ × 0.128″); or 4-3″ × 0.131″ nails At each joist or rafter, face nail 29 Bridging to joist 2-10d (3″ × 0.128″)Each end, toe nail ITEM DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENER a, b, c SPACING OF FASTENERS Edges (inches)h Intermediat e supports c, e (inches) Wood structural panels, subfloor, roof and interior wall sheathing to framing and particleboard wall sheathing to framing [see Table R602.3(3) for wood structural panel exterior wall sheathing to wall framing] 30 3/8″ – 1/2″ 6d common (2″ × 0.113″) nail (subfloor, wall) 8d common (21/2″ × 0.131″) nail (roof) 6 12f 31 19/32″ – 1″8d common nail (21/2″ × 0.131″)6 12f 32 11/8″ – 11/4″10d common (3″ × 0.148″) nail; or 8d (21/2″ × 0.131″) deformed nail 6 12 Other wall sheathing 33 1/2″ structural cellulosic fiberboard sheathing 1 1/2″ galvanized roofing nail, 7/16″ head diameter, or 1″ crown staple 16 ga., 1 1/4″ long 3 6 34 25/32″ structural cellulosic fiberboard sheathing 1 3/4″ galvanized roofing nail, 7/16″ head diameter, or 1″ crown staple 16 ga., 1 1/4″ long 3 6 35 1/2″ gypsum sheathingd 1 1/2″ galvanized roofing nail; staple galvanized, 1 1/2″ long; 1 1/4″ screws, Type W or S 7 7 36 5/8″ gypsum sheathingd 1 3/4″ galvanized roofing nail; staple galvanized, 1 5/8″ long; 1 5/8″ screws, Type W or S 7 7 Wood structural panels, combination subfloor underlayment to framing 37 3/4″ and less 6d deformed (2″ × 0.120″) nail; or 8d common (2 1/2″ × 0.131″) nail 6 12 38 7/8″ – 1″8d common (2 1/2″ × 0.131″) nail; or 8d deformed (2 1/2″ × 0.120″) nail 6 12 39 1 1/8″ – 1 1/4″10d common (3″ × 0.148″) nail; or 8d deformed (2 1/2″ × 0.120″) nail 6 12 1.REINFORCING STEEL SHALL BE PLACED IN ACCORDANCE WITH ACI 315 AND ACI 318, AND CRSI'S MANUAL OF STANDARD PRACTICE. 2.REINFORCING STEEL SHALL CONFORM TO ASTM A615OR ASTM 716(WELDABLE STEEL) AND SHALL BE GRADE 60 DEFORMED BARS, TYP., U.N.O. REINFORCING IN SLAB ON GRADE MAYBE GRADE 40 STEEL FOR BARS #4 AND SMALLER U.N.O ON THE PLANS. 3.WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A185. LAPS IN WWF SHALL BE SUCH THAT THE OVERLAP MEASURED BETWEEN OUTERMOST CROSS WIRE OF EACH FABRICH SEET IS NOT LESS THAN THE SPACING OF CROSS WIRES PLUS 2 INCHES. 4.ALL DIMENSIONS SHOWING THE LOCATION OF REINFORCING BARS/STEEL ARE TO THE CENTER OF STEEL U.N.O. ON THE PLANS OR DETAILS: CONDITION COVER A. CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" B. EXPOSED TO EARTH OR WEATHER (INCLUDING SLABS ON GRADE) #6 AND LARGER 2" #5 AND SMALLER 1 1/2" C. NOT EXPOSED TO WEATHER OR IN CONTACT WITH SOIL: 1. STRUCTURAL SLABS, WALLS w/ #11 BARS AND SMALLER 3/4" #14 BARS AND LARGER 1 1/2" 2. BEAMS, COLUMNS 1 1/2" 5.LAP SPLICES OF BARS SHALL CONFORM TO THE TYPICAL THE LAP SCHEDULE ON THE PLANS, U.N.O. NO TACK WELDING OF BARS ALLOWED 6.MECHANICAL SPLICE COUPLERS MAY BE USED AND SHALL HAVE CURRENT ICC APPROVAL AND BE CAPABLE OF DEVELOPING 125% OF THE BAR'S YIELD STRENGTH. 7.ALL REINFORCING BARS SHALL BE BENT COLD. DO NOT FIELD BEND OR UNBEND ANY BARS IN A MANNER THAT MAY DAMAGE REINFORCING. 8.REINFORCING SPACING SHOWN ON THE PLANS ARE THE MAXIMUM SPACING "ON CENTER SPACING". DO NOT EXCEED THIS. ANY DISCREPANCIES DURING CONSTRUCTION SHALL BE FORWARDED TO THE ENGINEER FOR REVIEW AND APPROVAL. 9.TYPICAL REINFORCING FOR CONCRETE SLAB ON METAL DECK SHALL BE 6x6-W1.4xW1.4 WELDED WIRE FABRIC, U.N.O. PLACE WWF MID-DEPTH OF THE SLAB OVER THE TOP OF THE FLUTE OF THE METAL DECK. 10.ALL DOWELS TO BE SET IN CONCRETE SHALL BE TIED IN PLACE PRIOR TO PLACEMENT OF CONCRETE. NO WET SETTING, STABBING, RODDING OR OTHER MOVEMENT OF EMBEDDED ITEMS SHALL BE PERFORMED DURING THE PLACEMENT OF CONCRETE. 11.DOWELS BETWEEN FOOTING AND WALLS OR COLUMNS SHALL BE THE SAME GRADE, SIZE AND SPACING AS THE MAIN REINFORCING, UNO. 12.CHAIRS OR SPACERS FOR REINFORCING SHALL BE NON-FERROUS OR PLASTIC COATED WHEN RESTING ON EXPOSED SURFACES. 1.CONCRETE SHALL BE SUPPLIED AND PLACED IN ACCORDANCE WITH THE LATEST EDITION OF ACI 318 AND ACI 301 EXCEPT AS MODIFIED BY THE CONSTRUCTION DOCUMENTS. 2.PORLAND CEMENT SHALL CONFORM TO ASTM C-150, TYPE II, U.N.O. 3.AGGREGATE FOR STONE CONCRETE SHALL CONFORM TO ASTM C-33. FOR LOWSHRINKAGE AGGREGATE, USE LIMESTONE OR GRANITE. AGGREGATE FORLIGHTWEIGHTCONCRETE SHALL CONFORM TO ASTM C-330 4.DO NOT USE ANY CONCRETE OR GROUT CONTAINING CHLORIDES. WATER USED IN MIXING CONCRETE SHALL CONFORM WITH ASTM C1602. 5.CONCRETE MIX DESIGNS CONTAINING FLY ASH MAY BE USED WHERE CONCRETE IS NOT VISUALLY EXPOSED. FLY ASH SHALL CONFORM WITH ASTM C618 AND MAY REPLACE UP TO 20% PORTLAND CEMENT BY VOLUME. 6.CONCRETE STRENGTH TEST REPORTS SHALL BE IN COMPLIANCE WITH ACI 318 AND SHALL BE SUBMITTED TO E.O.R. FOR REVIEW. 7.ALL REINFORCING BARS, ANCHOR BOLTS AND ALL OTHER CONCRETE INSERTS SHALL BE WELL SECURED IN POSITION PRIOR TO PLACING CONCRETE. 8.THE CONCRETE COMPRESSIVE STRENGTH (28 DAYS), f'c: a. ALL LOCATIONS, U.N.O: MIN 4500 PSI, (W/C = 0.45) SPECIAL INSPECTION IS REQUIRED WHEN f'c > 4500 PSI. b. CONCRETE IN CONTACT WITH SOIL CONTAINING SULFATE So4 ≥ 0.1% BY WEIGHT: 4500 PSI, SPECIAL INSPECTION IS NOT REQUIRED. c. CONCRETE IN CONTACT WITH SOIL CONTAINING SULFATE So4 ≥ 0.2% BY WEIGHT: 4500 PSI, SPECIAL INSPECTION IS NOT REQUIRED. 9.TIME BETWEEN CONCRETE BATCHING AND PLACEMENT SHALL BE IN ACCORDANCE WITH ASTM C94. 10.CONCRETE PLACEMENT/CURING/REDUCTION IN STRENGTH SHALL CONFORM TO ACI 305R AND 3065R REQUIREMENTS FOR HOT AND COLD WEATHER CONCRETING. 11.CONCRETE SHALL BE CURED PER ACI 308R, UNLESS ALTERNATE METHODS OF CURING HAVE BEEN APPROVED BY THE ARCHITECT OR ENGINEER. FOR SLAB CURING, CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING COMPATIBILITY OF CURING COMPOUNDS WITH PROPOSED FINISHES PRIOR TO COMMENCING ANY WORK. 12.MAX. SLUMP SHALL BE 5 INCHES EXCEPT WHERE ADMIXTURES/PLACITIZERS HAVE BEEN ADDED IN THE MIX DESIGN TO IMPROVE FLOW ABILITY/WORKABILITY. THE SLUMP LIMIT SHALL BE BASED ON ADMIXTURE MANUFACTURER'S RECOMMENDATIONS. 1.ALL STRUCTURAL LUMBER SHALL BE DOUGLAS FIR LARCH CONFORMING TO WEST COAST LUMBER INSPECTION BUREAU GRADING RULES #17. MOISTURE CONTENT NOT TO EXCEED 19% AT TIME OF CONSTRUCTION. 2.WOOD-BASED STRUCTURAL USE PANELS SHALL MEET THE REQUIREMENTS OF DOC PS 2-10. STRUCTURAL SHEATHING MAY BE EITHER OSB OR PLYWOOD. 3.STRUCTURAL COMPOSITE LUMBER (SCL) SHALL CONFORM TO THE MANUFACTURER'S ICC REPORT IN COMPLIANCE WITH THE GOVERNING BUILDING CODE FOR THE PROJECT LISTED. 4.ENGINEERED GLU-LAM BEAMS SHALL BE INSPECTED AND AN A.I.T.C. CERTIFICATE OF COMPLIANCE SHALL BE PROVIDED TO THE INSPECTOR PRIOR TO INSTALLATION. ALL GLU-LAM BEAMS SHALL BE FABRICATED WITH WATERPROOF GLUE WITH STANDARD CAMBER U.N.O. 5.GLU-LAM BEAMS MAY NOT BE SUBSTITUTED FOR STRUCTURAL COMPOSITE LUMBER (SCL) BEAMS UNLESS WRITTEN AUTHORIZATION IS PROVIDED BY THE ENGINEER OF RECORD. 6.ALL WOOD FRAMING MEMBERS DIRECTLY AGAINST CONCRETE OR MASONRY INSTALLED IN A DRY OR ENCLOSED ENVIRONMENT SHALL BE PRESSURE TREATED DOUG-FIR TREATED WITH SODIUM BORATE (SBX/DOT). CORROSION RESISTANT CONNECTORS ARE NOT REQUIRED WITH SODIUM BORATE TREATED LUMBER. IF OTHER TREATMENTS ARE USED, GALVANIZED FASTENERS PER "FASTENER REQUIREMENTS" NOTE 3 ARE REQUIRED. 7.LUMBER GRADE STAMPS ARE TO REMAIN IN PLACE AFTER INSTALLATION WHERE POSSIBLE. 8.LUMBER GRADES ARE TO BE AS FOLLOWS: STUDS UP TO 10'-0"..............................................................................................STUD GRADE STUDS OVER 10'-0".............................................................................................................DF #2 BLOCKING............................................................................................STANDARD OR BETTER PLATES & SILL.....................................................................................STANDARD OR BETTER TOP PLATES........................................................................................................................DF #2 4X4 BEAMS/POSTS.............................................................................STANDARD OR BETTER 4X6 THROUGH 4X12BEAMS/POSTS.................................................................................DF #2 4X14BEAMS/POSTS.............................................................................................................DF#1 6X & LARGER BEAMS/POSTS............................................................................................DF #1 2X RAFTER/JOIST...............................................................................................................DF #2 9.UTILITY GRADE LUMBER IS UNACCEPTABLE FOR ANY PURPOSE. 10.THE FOLLOWING BEAMS/HEADERS/RIMS CAN BE FROM ANY MANUFACTURER WITH CURRENT APPROVED ICC ES - EVALUATION REPORT WITH THE FOLLOWING MECHANICAL PROPERTIES: FOR "LVL" & "PSL" BEAMS: Fb = 2900 psi (MIN), Fv = 290 psi (MIN), E = 2.0 x 106 psi (MIN). FOR "LSL" BEAMS/HEADERS: Fb = 2325 psi (MIN), Fv = 400 psi (MIN), E = 1.55 x 106 psi (MIN). FOR MANUFACTURED RIM BOARD WITH MIN 1 1/4" THICK, CONTINUOUSLY SUPPORTED BY WALL , AND MATCHES JOIST DEPTH: Fc I (PERPENDICULAR)........ = 680 psi (MIN) Fc // (PARALLEL)..................... = 1400 psi (MIN) Ft = 1075 psi (MIN), E = 1.3 x 106 psi (MIN) GLU-LAM BEAM SHALL BE 24F-V4, DF/DF Fb = 2400 psi @ BOTTOM, Fb = 1850 psi @ TOP Fv = 265 psi (MIN), E = 1.8 x 106 psi (MIN). 11.ROOF SHEATHING SHALL BE 15/32" APA RATED SHEATHING EXP 1 WITH A SPAN RATING OF 24/0 WITH 8D NAILS AT 6" O/C AT EDGES AND BOUNDARIES AND 12" O/C FIELD NAILING. 12.FLOOR SHEATHING SHALL BE 23/32" APA RATED SHEATHING EXP 1 WITH A MINIMUM SPAN RATING OF 48/24 WITH 10D NAILS AT 6" O/C AT EDGES AND BOUNDARIES AND 10" O/C FIELD NAILING. FOUNDATION 1.THE FOUNDATION DESIGN IS BASED UPON CHAPTER 4 C.R.C. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIREMENTS THEREIN AND MAINTAIN A COPY ON THE JOB SITE AT ALL TIMES. 2.THE ENGINEER OF RECORD MUST BE INFORMED OF ANY CHANGES IN DESIGN CRITERIA MADE BY ANY SOILS GEOLOGIST IN THE COURSE OF CONSTRUCTION. 3.ALL FOOTINGS AND SLABS SHALL BE FOUNDED ON FIRM UNDISTURBED NATURAL SOILS OR APPROVED COMPACTED FILL. CONTRACTOR TO PROVIDE BUILDING INSPECTOR WITH COMPACTION REPORTS AND/OR WRITTEN APPROVAL OF COMPACTED FILL FROM A SOIL GEOLOGIST FOR ANY REQUIRED FILL. 4.ALL COMPACTED FILL SHALL BE PLACED IN AN APPROVED MANNER WITH A MINIMUM DENSITY OF 90% OF THE MAXIMUM OBTAINABLE IN ACCORDANCE WITH ASTM D 1557. 5.ALL FOUNDATION EXCAVATIONS, FILLING, BACK FILLING, AND BUILDING PADS SHALL BE INSPECTED AND APPROVED BY THE CITY BUILDING INSPECTOR BOTH PRIOR TO, AND AFTER PLACEMENT OF REINFORCEMENT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SHORING NECESSARY TO SUPPORT CUT AND/OR FILL SECTIONS DURING EXCAVATION AND FOR FORMING AND PLACEMENT OF CONCRETE. 6.THE CONTRACTOR SHALL INFORM THE ARCHITECT AND ENGINEER OF THE LOCATION OF EXISTING UTILITIES AND COMMENCE WORK ONLY AFTER WRITTEN APPROVAL FROM THE ARCHITECT. 7.ALL RETAINING WALLS HAVE BEEN DESIGNED AS A FREE DRAINING CONDITION. DESIGN FOR THE DRAINAGE SYSTEM SHALL BE BY OTHERS AND SHALL MEET THE REQUIREMENTS OF THE SOILS REPORT.BACK FILL AGAINST WALLS SHALL BE PLACED EVENLY AGAINST BOTH SIDES OF WALLS UNTIL THE LOWER GRADE IS REACHED. 8.FOOTING WITH MINIMUM REINFORCEMENT OF: 2#4 @ TOP & 2#4 @ BOTTOM. OR U.N.O 9.EXISTING FOOTING : USE EPOXY FOR A.B. WITH SAME LENGTH AS REGULAR BOLTS WITH SPECIAL INSPECTION. GENERAL 1.ALL CONCRETE MASONRY MATERIALS AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH BUILDING CODE, CHAPTER 21. MATERIALS 2.ALL MATERIALS MAKING UP FINISHED CONCRETE MASONRY CONSTRUCTION SHALL CONFORM TO STANDARDS REQUIRED BY BUILDING CODE SEC. 2103. 3.MORTAR SHALL BE TYPE M OR S AS APPLICABLE AND CONFORMING WITH ASTM C270 AND SHALL BE PROPORTIONED PER ARTICLE 2.1 & 2.6A OF SPECIFICATION FOR MASONRY STRUCTURES (TMS 602-16). 4.GROUT SHALL COMPLY WITH ARTICLE 2.2 OF TMS 602-16 AND SHALL ATTAIN A MINIMUM COMPRESSION STRENGTH AT 28 DAYS OF 1500 PSI OR THE REQUIRED COMPRESSION, F'M, WHICHEVER IS GREATER. THE COMPRESSIVE STRENGTH OF GROUT SHALL BE DETERMINED IN ACCORDANCE WITH ASTM C-1019. 5.CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90 FOR LOAD BEARING CONCRETE MASONRY UNITS. CONCRETE BRICK SHALL CONFORM TO ASTM C55, SPECIFICATIONS FOR CONCRETE BUILDING BRICK. 6.GRADE N CONCRETE BRICKS ARE FOR USE AS ARCHITECTURAL VENEER AND FACING, LIMITED TO IN EXTERIOR WALLS. 7.GRADE S CONCRETE BRICKS ARE FOR GENERAL USE WHERE MODERATE STRENGTH AND RESISTANCE TO FROST ACTION AND MOISTURE PENETRATION IS REQUIRED. STRENGTH 8.THE SPECIFIED COMPRESSIVE STRENGTH OF MASONRY, F'M, SHALL BE 2000 PSI, UNLESS NOTED OTHERWISE. IF HIGHER F'M IS NOTED, IT SHALL BE VERIFIED BY PRISM TESTS AS REQUIRED IN ARTICLE 1.4 SPECIFICATION OF MASONRY STRUCTURES (TMS 602-16). 9.REINFORCING STEEL SHALL CONFORM TO ASTM A615. GRADE 40 FOR SIZES #3 AND GRADE 60 FOR SIZES #4 AND LARGER. SPECIAL INSPECTION 10.SPECIAL INSPECTION FOR CONCRETE MASONRY CONSTRUCTION SHALL BE CARRIED OUT IN ACCORDANCE WITH BUILDING CODE SECTION 1704 AND REQUIREMENTS IN SPECIAL INSPECTION TABLES ON SHEET SN-1. MASONRY COMPRESSIVE STRENGTH, F'M SHALL BE VERIFIED BY UNIT STRENGTH METHOD OR PRISM TEST METHOD PRIOR TO AND DURING CONSTRUCTION AS DESCRIBED IN ARTICLE 1.4 SPECIFICATION FOR MASONRY STRUCTURES (TMS 602-16). 1.SOILS SOILS ALLOWABLE DESIGN VALUES IS 1500 PSF, 2.BUILDING CODE - 2022 CALIFORNIA BUILDING CODE 3.DESIGN LOADS: 4.LATERAL LOADS: ROOF LOAD DEAD LOAD = 20 PSF LIVE LOAD = 20 PSF TOTAL = 40 PSF RISK CATEGORY: II SEISMIC DESIGN CATEGORY: D SEISMIC IMPORTANCE FACTOR (I) = 1.0 SITE CLASS = D WIND SPEED:95 MPH WIND EXPOSURE:C Ss:1.315 S1:0.468 Csy:0.113 Ry:6.5 Csx:0.113 RX: 6.5 DESIGN CRITERIA SHEET INDEX No.SHEET NO.SHEET NAME 1 S0.0 - GENERAL STRUCTURAL NOTES. 2 S0.1 - TYPICAL DETAILS. 3 S1.0 - FOUNDATION & FRAMING PLAN. 4 SD1 - STRUCTURAL DETAILS. BASIC SEISMIC FORCE RESISTING SYSTEM: PLYWOOD SHEAR WALL ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE TYPE ALLOWABLE SHEAR (PLF) 1 2 3 4 5 260 PLF 380 PLF 490 PLF 640 PLF 800 PLF 3/8" APA STRUCT. RATED PLYWOOD (or OSB) WITH 8d COMMON NAILS AT 6" O.C. EDGES AND 12" O.C. FIELD 3/8" APA STRUCT. RATED PLYWOOD (or OSB) WITH 8d COMMON NAILS AT 4" O.C. EDGES AND 12" O.C. FIELD 3/8" APA STRUCT. RATED PLYWOOD (or OSB) WITH 8d COMMON NAILS AT 3" O.C. EDGES AND 12" O.C. FIELD 3/8" APA STRUCT. RATED PLYWOOD (or OSB) WITH 8d COMMON NAILS AT 2" O.C. EDGES AND 12" O.C. FIELD 15/32" APA STRUCT I. RATED PLYWOOD WITH 10d COMMON NAILS AT 2" O.C. EDGES AND 12" O.C. FIELD PANEL SILL PLATE NAILING (16D SINKER) 6" O.C., OR A35 @ 24" O.C. 4" O.C., OR A35 @ 16" O.C. 3" O.C., OR A35 @ 12" O.C. 2" O.C., OR A35 @ 10" O.C. (2)3" O.C., OR A35 @ 6" O.C. FRAMING CLIP A35's,LS50's OR LTP4's. 16" O.C. 12" O.C. 8" O.C. 6" O.C. 5" O.C. 5/8" Ø A.B. SPC'G 48" 42" 36" 24" 18" SHEAR WALL SCHEDULE 5 4 3 1 2 R E V I S I O N 11122 BIXLER CIR., PHONE: 657-820-6210 EMAIL: INFO@PBDINC.ORG GARDEN GROVE, CA92840 PROFESSIONAL BUILDING DESIGNS, INC. THIS DRAWING AND DESIGN CONCEPTS ARE PROPRIETARY TO PBD, INC. THE DRAWING OR DESIGN CONCEPTS SHALL NOT BE USED OR REPRODUCED IN THE PART OR IN WHOLE WITHOUT THE WRITTEN PERMISSION BY PBD, INC. ARCHITECTURAL - STRUCTURAL MECHANICAL - ELECTRICAL - PLUMBING RESIDENTIAL - COMMERCIAL - INDUSTRIAL ON TIME - ON BUDGET - PROFESSIONAL WORK ONE STOP SOLUTION PBD SHEET NO.: DRAW BY: DUY NGUYEN PLOTE DATE: JOB NO.: 25655 C 69546 Exp: 06/30/26 TUNG THANH VO C I V I LSTATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER 01/30/2026 2 C A R G A R A G E C O N V E R T T O A D U RE S I D E N T I A L P R O J E C T F O R Pr o j e c t A d d r e s s : 2 1 2 9 N H a t h a w a y S t . S a n t a A n a , C A 9 2 7 0 5 01/30/2026 BLDG CMNT. DATE BY GE N E R A L ST R U C T U R A L N O T E S S0.0 02/06/26 5 4 3 1 2 R E V I S I O N 11122 BIXLER CIR., PHONE: 657-820-6210 EMAIL: INFO@PBDINC.ORG GARDEN GROVE, CA92840 PROFESSIONAL BUILDING DESIGNS, INC. THIS DRAWING AND DESIGN CONCEPTS ARE PROPRIETARY TO PBD, INC. THE DRAWING OR DESIGN CONCEPTS SHALL NOT BE USED OR REPRODUCED IN THE PART OR IN WHOLE WITHOUT THE WRITTEN PERMISSION BY PBD, INC. ARCHITECTURAL - STRUCTURAL MECHANICAL - ELECTRICAL - PLUMBING RESIDENTIAL - COMMERCIAL - INDUSTRIAL ON TIME - ON BUDGET - PROFESSIONAL WORK ONE STOP SOLUTION PBD SHEET NO.: DRAW BY: DUY NGUYEN PLOTE DATE: JOB NO.: 25655 C 69546 Exp: 06/30/26 TUNG THANH VO C I V I LSTATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER 01/30/2026 2 C A R G A R A G E C O N V E R T T O A D U RE S I D E N T I A L P R O J E C T F O R Pr o j e c t A d d r e s s : 2 1 2 9 N H a t h a w a y S t . S a n t a A n a , C A 9 2 7 0 5 01/30/2026 BLDG CMNT. DATE BY 1 2 3 4 6 TYPICAL FLOOR/ROOF OPENING DETAIL PROVIDE EDGE NAILING TO ALL EDGES OF OPENING. DOUBLE JOIST OR RAFTER EACH SIDE OF OPENINGPER SCHEDULE SIMPSON HANGER BLOCKING WHERE (PROVIDE FILLER REQUIRED)NOTE: JOIST OR RAFTER SEE PLAN OPENING SEE PLAN BEAM OR GIRDER 8'-0" MAX. 4' - 0 " M A X . CEILING JOIST PARALLEL TO WALL NEW CEILING JOIST PER PLAN. 2x8 LEDGER w/ (2) 16d'S NAIL @ 16" OC INTO STUDS STUDS WALL CEILING JOIST PERPENDICULAR TO WALL NEW CEILING JOIST PER PLAN. 2x8 LEDGER w/ (2) 16d'S NAIL @ 16" OC INTO STUDS SIMPSON HANGER JOIST.1/2" DRYWALL AT BOTTOM OF CEILING JOISTS CEILING JOIST TO WALL DETAIL PERPENDIULAR TO ROOF FRAMING PARALLEL TO ROOF FRAMING 2x STUD SEE ARCH'L FOR SIZE AND SPACING 1/ 4 " ~ 1 / 2 " CL R . 1/ 4 " ~ 1 / 2 " CL R . 2x6 BLOCKING W/SIMPSON "LUS" HANGER EA. END SIMPSON "DTC" CLIP @48"o.c. SIMPSON "DTC" CLIP @48"o.c. CEILING SEE ARCH'L (2)2x TOP ~P'S CEILING JOIST TYPICAL NON-BEARING PARTITION WALL AT ROOF FRAMING DETAIL 9 10 11 STUD NOTCHING AND BORING DBL. TOP PLATES STUD, TYP. BORED HOLE MAX. DIAMETER 40% OF STUD DEPTH 5/8 " MIN. TO EDGE NOTCH MUST NOT EXCEED 25% OF STUD DEPTH BORED HOLES SHALL NOT BE LOCATED IN THE SAME CROSS SECTION OF CUT OR NOTCH IN STUD IF HOLE IS BETWEEN 40% AND 60% OF STUD DEPTH THEN STUD MUST BE DOUBLE AND NO MORE THAN TWO SUCCESSIVE STUDS ARE DOUBLE AND SO BORED 25% 40%5/8 " D NOTCH/BORE % OF STUD 2x4 STUDS 2x6 STUDS 2x8 STUDS 25% 40% 60% 7/8" 1-3/8" 2" 1-3/8" 2-1/8" 3-1/4" 1-3/4" 2-7/8" 4-1/4" DBL. TOP PLATES STUD, TYP. BORED HOLE MAX. DIAMETER 60% OF STUD DEPTH 5/8" MIN. BORED HOLES SHALL NOT BE LOCATED IN THE SAME CROSS SECTION OF CUT OR NOTCH IN STUD TO EDGE NOTCH MUST NOT EXCEED 40% OF STUD DEPTH 40% 60% MIN. D D60% MIN.D D D 60%D5/8 " D 12 13 ROOF/FLOOR DIAPHRAGM LAYOUT FIELD NAILING EDGE NAILING AT ALL BLOCKED EDGES BLK'G. AT DIAPHRAGM EDGES EDGE NAILING BLOKED SHT'G. UNBLOKED SHT'G. SHEATHING ABOVE FRAMING MEMBERS BELOW FIELD NAILING EDGE NAILING NO EDGE NAILING AT UNBLOCKED EDGES NOTE: 1.SEE SHEET S0.0 EOR PLYWOOD THICKNESS, NAILING AND ADDITIONAL NOTES. 2.PANELS SHALL NOT BE LESS THAN 4 FT. X 8 ET. EXCEPT AT BOUNDARIES AND CHANGES IN FRAMING WHERE MINIMUM PANEL DIMENSIONS SHALL BE 24" UNLESS ALL EDGES OF THE UNDERSIZED PANELS ARE SUPPORTED BY FRAMING MEMBERS OR BLOCKING. 3.LONG DIMENSION OF PLYWOOD SHALL RUN ACROSS (PERPENDICULAR TO) JOISTS OR RAFTERS. 4.NAILS SHALL NOT BE DRIVEN THROUGH OUTER PLY. 5.BLOCKED SHT'G. (WHERE INDICATED) REQUIRES ALL PANELS EDGES TO RECEIVE EDGE NAILING. 6.WHERE JOISTS OR RAFTERS LAP SPLICE OCCURS AND PLYWOOD JOINT IS CONTINUOUS. VENEER TO WOOD WALL STEEL ANGLE SCHEDULE SIZE L4x3 1/2x3/8 L6x3 1/2x1/2 L7x4x5/8 8'-0" 14'-0" 16'-0" EXTERIOR SHEATHING SEE ARCH. FOR INSULATION AND MEMBRANE STUD WALL PER PLAN BEAM OR HEADER PER PLAN 1/2" DIA. LAG SCREW @12" O.C. WITH 2.5" MIN. EMBED TO BEAM OR HEADER LLV STEEL ANGLE SUPPORT 3'-6" VENEER HEIGHT MAX AND NEED TO EXTENT AND BEAR ON EACH SIDE OF OPENING 4" MIN. SEE SCHEDULE FOR SIZE FERO PAC-TIE WITH 2-#6 x 2" DECK SCREW AND WASHERS AS FOLLOWS: - TYPICAL AT 16" HORIZONTAL AND AT 24" VERTICAL - AROUND OPENINGS AT 12" HORIZONTAL AND AT 16" VERTICAL - NOT MORE THAN 12" FROM EDGE OF OPENINGS. - LOCATE ROW OF TIES MAX 12" ABOVE BEARING LEVEL AND 8" FROM TOP OF WALL. ADD 9 GAUGE WIRE JOINT REINF. @24" O.C. VERTICAL FOR BUILDING IN SEISMIC DESIGN CATEGORIES C, D, E, F.OPENING SPAN MAX. DRILLING HOLES AND NOTCHING OF THE JOIST D 13 SPAN HOLES AND NOTCHES ALLOWED 13 SPAN HOLES AND NOTCHES ALLOWED 13 SPAN HOLES AND NOTCHES ALLOWED D/3 (RAFT. OR C.J.) D/4 (FLOOR JOIST) D/ 6 D/ 6 MIN. 12"D/ 3 MI N . 2" MI N . 2" D D/ 4 ALTERNATE BOTTOM NOTCH NOTE: 1.DO NOT NOTCH BOTH TOP AND BOTTOM SURFACES WITHIN THE SAME 1/3 SPAN. 2.MAX. ALLOWED IS A COMBINATION OF TWO NOTCHES AND/OR HOLES PER 1/3 SPAN. 3.THIS DETAIL DOES NOT APPLY TO NOTCHES AND HOLES IN STRUCTURAL BEAMS, THEY MUST BE SPECIFICALLY DETAILED. 4.NOTCHES AND HOLES ARE NOT ALLOWED IN CANTILEVERED SEGMENTS OF JOISTS. 5.REFER TO MANUFACTURER'S RECOMMENDATIONS FOR NOTCHES AND HOLES WHERE I-JOIST TRUSSES ARE USED. 6.ANY OVER CUTS ARE TO BE INCLUDED IN THE MAXIMUM NOTCH DEPTH DIMENSION. JOIST SIZE MAX. NOTCH DEPTH: D/4 MAX. NOTCH DEPTH: D/6 MAX. SIZE HOLE: D/3 2X6 2X8 2X10 2X10 2X14 1-3/8" 1-3/4" 2-1/4" 2-3/4" 3-1/4" 7/8" 1-1/8" 1-1/2" 1-7/8" 2-1/8" 1-1/2" 2-3/8" 3" 3-3/4" 4-3/8" UPPER TOP PLATE 3/8" TYP. SHEAR WALL PENETRATIONS SHEAR WALL NAILING SHEATHING PER PLAN FIELD NAILING 6" M I N . HOLES TO BE MIN. 6" FROM PLATES, TYP. FOR HOLES UP TO 16" SQ., PROVIDE BLKG. AND E.N., HOLES LESS THAN 5" SQ. DO NOT REQUIRE BLKG. OR E.N. EDGE NAILING PER PLAN, TYP. FRAMING MEMBER PER SHEAR WALL SCHEDULE 1.SHEAR WALL EDGE NAILING TO HAVE MIN. EDGE DISTANCE OF 3/8". 2.WHEN SHEATHING IS NAILED TO TRIMMER, TRIMMER AND KING STUD TO BE STITCH NAILED TOGETHER WITH 16D'S, SPACING TO MATCH EDGE NAILING OF SHEAR WALL. 3.SHEAR WALL PENETRATIONS ARE TO BE IN CONFORMANCE WITH THE DETAIL BELOW. LIMIT ONE PENETRATION GREATER THAN 5" SQUARE PER STUD BAY. CUTS TO BE MINIMUM 16" FROM EDGE OF SHEAR WALL, ALL DIRECTIONS. 4.CONTACT ENGINEER OF RECORD FOR HOLES LARGER THAN 16" SQUARE. 5.TOTAL LENGTH OF OPENINGS SHALL NOT EXCEED 20% OF THE TOTAL WALL LENGTH. PRESSURE TREATED SILL PLATE w/ A.B.'s PER SHEAR WALL SCHEDULE HOLDOWN AS OCCURS, TYP. 2x STUD TYP. MIN 3x POST AT SHEAR WALL TYPES 1, 2 & 3. SHEAR PANEL w/ E.N. PER PLAN, MIN. WIDTH OF PANEL = 16" 2x4 STUDS AT 16"O.C. TYP., U.N.O. HDR. 6" DEEP & LESS PROVIDE (2) 16d, TRIM. TO HDR., ADD (1) 16d FOR EA. ADD'L 2" OF DEPTH USE LTP4 EA. SIDE WHEN GREATER THAN 2x KING POST 2x KING STUD AT NO HOLDOWN CONDITION OR POST PER PLAN AT HOLDOWN CONDITION. PER TABLE ABV. HEADER PER PLAN 2x TRIM. U.N.O. STITCH NAIL w/ 16d AT 6" o/c AT SHEAR WALLS, 16d AT 12" o/c AT NON-SHEAR WALLS E.N. PER SHEAR WALL SCHEDULE HOLDOWN AS OCCURS MIN. 1/8" STAGGER AT 2" E.N. FRAMING PLATE E.N. INTO UPPER TOP PLATE 1/8" 3/8"3/8" TYPICAL WALL FRAMING5 SHEAR WALL/ INTERSECTION PLYWOOD AT INTERSECTION w/ POST POST AT PER PLAN INTERSECTION w/o POST 16d @ 12" O.C. OUTSIDE CORNER w/ POST NOTE: SEE FRAMING PLAN FOR SHEAR WALL LOCATIONS, ORIENTATIONS AND SCHEDULE REFERENCES DOUBLE 2x, MIN. OUTSIDE CORNER w/o POST DOUBLE-SIDED WALL POST AT PER PLAN 16d @ 12" O.C.16d @ 12" O.C. FOR 2x STUD 20d @ 6" O.C. FOR 3x STUD PLY. CONT. THRU WALL INTERSECTION ATDOUBLE-SIDED WALL 16d @ 12" O.C. FOR 2x STUD 20d @ 6" O.C. FOR 3x STUD 2x OR 3x STUD AS REQ'D., TYP. PER S.W. SCHED. 7 8WOOD SHEARWALL SILL PLATE ANCHORAGE SHEARWALL WHERE OCCURS SILL PLATE ANCHORAGE PER SHEARWALL SCHEDULE CONCRETE SLAB OR PRECAST PLANK SHEARWALL SHEATHING SEE PLAN AND SCHEDULE PLATE WASHER 3 GA x 3 x 3- .229" MIN THICKNESS 12" MAX12" MAX E.Q.E.Q. 2x4 SHEAR WALLS AND ALL DOUBLE SIDED SHEAR WALLS TYPICAL NON-BEARING PARTITION WALL AT ROOF FRAMING DETAIL PERPENDIULAR TO TRUSS FRAMING PARALLEL TO TRUSS FRAMING 2x STUD SEE ARCH'L FOR SIZE AND SPACING 1/ 4 " ~ 1 / 2 " CL R . CL R . SIMPSON "DTC" CLIP @48"o.c. CEILING SEE ARCH'L (2)2x TOP ~P'S TRUSS BOTTOM CHORD 1/ 4 " ~ 1 / 2 " 2x6 BLOCKING W/SIMPSON "LUS" HANGER EA. END SIMPSON "DTC" CLIP @48"o.c. TYPICAL NON-BEARING PARTITION WALL AT SAWN LUMBER FRAMING DETAIL FLOOR JOIST PARALLEL TO WALL FLOOR JOIST PERPENDICULAR TO WALL 2x BLOCKING @ 24"o.c. (2)16d TOE NAIL AT JOIST TO PLATE 2x BLOCKING (CONT.)(2)16d TOE NAIL 16d @ 24"o.c.16d @ 16"o.c. TOP PLATE SPLICING, NOTCHING & BORING STANDARD PLATE SPLICE CONDITION ALL EXTERIOR, BEARING OR SHEAR WALLS, U.N.O. ON PLAN PLATE SPLICE COND. PER PLAN NON-LAPPED CHANNEL CONDITION ALLOWABLE TOP PLATE NOTCHING AND BORING ALL EXTERIOR BEARING OR SHEAR WALLS 2X UPPER TOP-PLATE (12)- 16d P-NAIL (GUN) EACH SIDE OF SPLICE, U.N.O. (ALT. CS16x36")^3 2X LOWER TOP-PLATE LOCATE STUD AT ALL SPLICES TYPICAL UPSIZED CONDITION WHERE SPECIFICALLY INDICATED ON PLANS ST OR MST TYPE STRAP MUST BE PLACED ON TOP OF UPPER PLATE THE NUMBER OF SPLICES MAY BE REDUCED BY NOT CUTTING PLATES AT INTERIOR WALL INTERSECTIONS THE NUMBER OF SPLICES MAY BE REDUCED BY NOT CUTTING PLATES AT INTERIOR WALL INTERSECTIONS SHIM W(2) - 16d (AT 1X PLATE COND. ONLY) FOR HEIGHT ADJUSTMENT LTP4 PER INTERSECTION CONT. 2-2X TOP PLTS. EXTERIOR WALL 1X OR 2X PLATE 2X STUD AT CHANNEL EQ.EQ. REQUIRED TOP PALTE SPLICE (PER PLAN) STANDARD ST6224 MST48 CONT. DBL. TOP PLATES "NOTCH/BORE" DIMENSION OR +B2 B1 4,5 2,3 STRAP NOT REQUIRED STRAP REQUIRED PLAN VIEW PLAN VIEW ST6236 1 MIN. 1-1/4" MIN. 1-3/4" MIN. 2-5/8" MIN. 3-1/2" MIN. 2-3/4" MIN. 1/2" to 1-1/4" MIN. 1-3/8" to 2-5/8" MIN. 1/2" to 1-3/4" MIN. 2-3/8" to 3-1/2" (1) - CS16 (1) - CS16 (1) - CS16 (1) - CS16 CALL ENGINEER MAX. 2" .2" TOP PLATES "NOTCH/BORE" CS16 W/(12)-8d NAILS ON EACH SIDE (WHERE REQ'D. BY CHART ABOVE)NOTCH CONDITION BORE CONDITION 1 6" A A B1 B2 48" MINIMUM LAP 14 TY P I C A L D E T A I L S S0.1 TYPICAL NOTCHED BEAMS MATCH SLOPE OF ROOF OVERALL BEAM DEPTH. FLUSH BEAM NOTCHED AS SHOWN. DBL.TOP PLATE, DBM. BEAM OR POST. MIN.5" FOR 14" DEEP BEAM & MIN. 4" FOR 11 7/8" DEEP BEAM. SEE PLANS HIGHER HEEL STAND IS REQ'D 02/06/26 FRAMING SCHEDULE PAD SCHEDULE PAD 2'-0" SQ. X 24" DEEP PAD W/ (3) #4 E.W. SYM. F2.0 2'-6" SQ. X 24" DEEP PAD W/ (3) #4 E.W. 3'-0" SQ. X 24" DEEP PAD W/ (3) #4 E.W. F2.5 F3.0 LEGEND 3'-6" SQ. X 24" DEEP PAD W/ (3) #4 E.W.F3.5 DESCRIPTIONSYM. F2.0 POST OR TRIMMER AS NOTED SDX X PAD NUMBER DETAIL NUMBER DETAIL SHEET NUMBER DROP IN SLAB (VERIFY PRIOR TO CONSTRUCTION) SHEAR PANEL LENGTH AND NUMBER, STRAP & POST EACH THE END SHEARWALL PER SHCEDULE & PLAN. REFER TO SD-0 FOR PANEL TYPE, MIN. 2-2x4 @ EA. END. INDICATES ROOF TRUSSES BY TRUSS SUPPLIER INDICATES FLOOR JOISTS BY JOIST SUPPLIER,OR U.N.O PER SCHEDULE & PLAN INDICATES DECK JOIST OR ROOF RAFTER PER SCHEDULE & PLAN X BEAM NUMBER, REFER TO REPORT CALCULATIONS KEY NOTE NUMBER BEARING WALL CALIFORNIA FRAMING XX GREATE BEAM @ FOUNDATION SEE PLAN FOR SIZE KEY NOTES FJ RR RT X NUMBER OF ANCHOR BOLTS LINE OF 2X FLAT BLOCKING W/ EDGE NAIL. & CONTINUOUS CS16 STRAP OVER U.N.O. SEE PLAN FOR NUMBER OF BAYS. BLOCKED FLOOR DIAPHRAGM W/ 10d's @ 4" O.C. B.N., 4" O.C. E.N. & 12" O.C. FIELD. BLOCKED ROOF DIAPHRAGM W/ 8d's @ 4" O.C. B.N., 4" O.C. E.N. & 12" O.C. FIELD. PROVIDE SOLID BLOCKING TRUSS HANGER BY TRUSS SUPPLIER CONTINUOUS FULL HT. BLKG. W/E.N. SEE PLANS FOR NUMBER OF BAYS ( U.N.O.) 1 2 3 4 5 6 EXISTING SLAB & FOOTING INDICATES CEILING JOIST PER SCHEDULE & PLANCJ NEW FOOTING SYMBOL SIZE MAX. SPACING U.N.O 4'-0" SQ. X 24" DEEP PAD W/ (3) #4 E.W.F4.0 4'-6" SQ. X 24" DEEP PAD W/ (3) #4 E.W.F4.5 NEW SLAB CONSTRUCTION NOTES 1.REFER TO STRUCTURAL GENERAL NOTES AND DETAIL SHEETS (S1.0 & S0.0) FOR MORE INFORMATION. 2.CONTRACTOR IS RESPONSIBLE FOR VERIFYING PREFABRICATED SHEAR WALLS AND MATCH TOP PLATE HEIGHT AND WALL WIDTH AND NOTIFY ENGINEER OF RECORD IF DIFFERENT THAN PLANS. 3.AS AN ALTERNATE TO USING SIMPSON PRODUCTS OTHER CONNECTORS CAN BE USED, AS LONG AS THEIR CAPACITIES ARE EQUAL TO OR BETTER THAN SIMPSON'S. 4.USE SIMPSON " IUS " HANGERS FOR CONNECTION OF I-JOISTS TO OTHER FRAMING MEMBERS (U.N.O.) AND " LUS " HANGERS FOR CONNECTION OF SOLID JOISTS. 5.USE ST6224 STRAP FOR THE TOP PLATES SPLICE AT ROOF FRAMING LEVELS (5B/SD2.0), UNO ON PLANS. 6.USE ST22 STRAP FOR LEDGER SPLICES, UNO. 7.USE (1)CS16 X 3'-0" STRAP AT RIM JOISTS SPLICE, U.N.O ON PLANS. 1¼” MIN. LVL RIM JOISTS SHOULD BE USED AT ALL FLOOR FRAMING EDGES. 8.PLYWOOD IS APPLIED ON EITHER SIDE OF SHEAR WALLS 9.INTERIOR NON-BEARING WALLS MAY BE FRAMED WITH 2X STUDS AT 24" O.C., MAX. 10.HEARDER AT OPENING AT EXTERIOR & INTERIOR BEARING WALL SHOULD BE MIN. 4X6 ,U.N.O 11.HEADER AT NON-BEARING WALLS, USE 2X4 FOR OPENINGS UP TO 3'-0" MAX., (2)2X4 FOR OPENINGS UP TO 6'-0" MAX., 4X6 FOR OPENINGS UP TO 12'-0" MAX., (UNO). 12.2X6 WALL SHOULD BE AT PLUMPING WALL. 13.TOTAL MINIMUM NUMBER OF ANCHOR BOLTS. REQUIREMENTS. FOR NON-SHEAR WALLS, MASA/MASAP MUDSILL ANCHORS CAN BE USED IN LIEU OF ANCHOR BOLTS WITH END DISTANCE OF 4" MIN. PER ESR #2555. 14.FOUNDATION ANCHOR BOLTS IN CONTACT WITH PRESSURE TREATED SILL PLATE SHALL BE OF HOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. 15.SIMPSON SET-3G EPOXY ESR-4057 SPECIAL INSPECTION REQUIRED 24" O.C.CJ 2X10 CJ X X'-X" (N) ENTRY (N) CONC LAND'G (N) BEDRM (N) BA (N) KITCH (N) LIV'G RM SH & POLE (N) DINE IN W/H (E) BEDRM 3 (E) BEDRM 4 (E) BA 1 (E) BA 2 (E) KITCH (E) ENTRY (E) FAMILIY ROOM W/H REF. (E) HDR. (E) HDR. (E ) H D R . (E) HDR. (E) HDR. (E ) H D R . (E ) H D R . (E ) H D R . (E ) H D R . (E ) H D R . 4X 6 4X 8 4X 6 4X 1 0 4X 6 (N) WALL (E) WALL WALL LEGEND E CJ EXISTING ROOF SYSTEM TO BE REMAINED, VERIFY ON FIELD. 2 5' - 0 " 15A SD1 11 SD1 4X4 4X4 2 3' - 9 " 11 SD1 4X4 15A SD1 4X4 10 S0.1 TYP. E EXISTING ROOF SYSTEM TO BE REMAINED, VERIFY ON FIELD. 21 R1 (E ) H D R . (N) ENTRY (N) CONC LAND'G (N) BEDRM (N) BA (N) KITCH (N) LIV'G RM SH & POLE (N) DINE IN W/H (E) BEDRM 3 (E) BEDRM 4 (E) BA 1 (E) BA 2 (E) KITCH (E) ENTRY (E) FAMILIY ROOM W/H REF. (N) WALL (E) WALL WALL LEGEND 2 5' - 0 " 2 3' - 9 " EXISTING FOOTING ASSUMED 12" X12" , VERIFY ON FIELD. EXISTING CONCRETE SLAB HDUE 3 HDUE 3 2 5 SD1 2 SD1 5 SD1 4 SD1 HDUE 3 HDUE 3 2 5 SD1 2 SD1 5 SD1 9 SD1 TYP. EXISTING CONCRETE SLAB EXISTING FOOTING ASSUMED 12" X12" , VERIFY ON FIELD. APPLY TWO COATS OF REDGARD VAPOR BARRIER (ICC-ESR #1413) OVER EXISTING SLAB NOTE: * VERIFY IN FIELD (E) FOOTING @ GARAGE DOOR IF NOT, PROVIDE (N) 12" W X 24" D W/(2) #4 T&B. ** VERIFY (E) FOOTING AT GARAGE IF NOT, PROVIDE (N) FOOTING 12"W X 14"D W/ (2) #4 T&B. (**) (* * ) (* ) (* * ) (* * ) 3 SD1 TYP. 16 SD1 TYP. (**) 5 4 3 1 2 R E V I S I O N 11122 BIXLER CIR., PHONE: 657-820-6210 EMAIL: INFO@PBDINC.ORG GARDEN GROVE, CA92840 PROFESSIONAL BUILDING DESIGNS, INC. THIS DRAWING AND DESIGN CONCEPTS ARE PROPRIETARY TO PBD, INC. THE DRAWING OR DESIGN CONCEPTS SHALL NOT BE USED OR REPRODUCED IN THE PART OR IN WHOLE WITHOUT THE WRITTEN PERMISSION BY PBD, INC. ARCHITECTURAL - STRUCTURAL MECHANICAL - ELECTRICAL - PLUMBING RESIDENTIAL - COMMERCIAL - INDUSTRIAL ON TIME - ON BUDGET - PROFESSIONAL WORK ONE STOP SOLUTION PBD SHEET NO.: DRAW BY: DUY NGUYEN PLOTE DATE: JOB NO.: 25655 C 69546 Exp: 06/30/26 TUNG THANH VO C I V I LSTATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER 01/30/2026 2 C A R G A R A G E C O N V E R T T O A D U RE S I D E N T I A L P R O J E C T F O R Pr o j e c t A d d r e s s : 2 1 2 9 N H a t h a w a y S t . S a n t a A n a , C A 9 2 7 0 5 01/30/2026 BLDG CMNT. DATE BY ROOF FRAMING PLAN SCALE : 1/4" = 1'-0" FO U N D A T I O N & F R A M I N G P L A N S1.0 FOUNDATION PLAN SCALE : 1/4" = 1'-0" 1 1 1 ROOF PLAN A.D.U. (ROOF VENTS) SCALE: 1/4" = 1'-0" (*) (**) (**) (**) 30" L #4 REBAR DOWELL 18" L #4 REBAR @ 18" O/C w/ EPOXY 1 AD1 2 AD1 02/06/26 5 4 3 1 2 R E V I S I O N 11122 BIXLER CIR., PHONE: 657-820-6210 EMAIL: INFO@PBDINC.ORG GARDEN GROVE, CA92840 PROFESSIONAL BUILDING DESIGNS, INC. THIS DRAWING AND DESIGN CONCEPTS ARE PROPRIETARY TO PBD, INC. THE DRAWING OR DESIGN CONCEPTS SHALL NOT BE USED OR REPRODUCED IN THE PART OR IN WHOLE WITHOUT THE WRITTEN PERMISSION BY PBD, INC. ARCHITECTURAL - STRUCTURAL MECHANICAL - ELECTRICAL - PLUMBING RESIDENTIAL - COMMERCIAL - INDUSTRIAL ON TIME - ON BUDGET - PROFESSIONAL WORK ONE STOP SOLUTION PBD SHEET NO.: DRAW BY: DUY NGUYEN PLOTE DATE: JOB NO.: 25655 C 69546 Exp: 06/30/26 TUNG THANH VO C I V I LSTATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER 01/30/2026 2 C A R G A R A G E C O N V E R T T O A D U RE S I D E N T I A L P R O J E C T F O R Pr o j e c t A d d r e s s : 2 1 2 9 N H a t h a w a y S t . S a n t a A n a , C A 9 2 7 0 5 01/30/2026 BLDG CMNT. DATE BY ST R U C T U R A L D E T A I L S SD1 1 2 4 NEW EXTERIOR FOOTING (2)#4 REBAR CONT. T & B (U.N.O.). STUD WALL SHEAR PANEL WHERE OCCURS WITH B.N. AT SILL PLATE 8" MI N . P.T.D.F. SILL PLATE W/ ANCHOR BOLTS PER 2/SD1. (MIN. 5/8" DIAMETER @ 48" O.C.) 3" W PER SCHED. #3 @ 24" O.C. BENT 3' INTO SLAB VAPOR BARRIER. WHERE OCCURS EXTEND 1.1/2" INTO FTG. SLOPE TO DRAIN SCREED 26 GAUGE @ STUCCO FINISH F.G. FOOTING DIMENSIONS # OF STORIES W WIDTH D DEPTH 1 12"24" 2 15"24" MIN.4" THK. CONC. SLAB w/ #4 @ 18" O.C. EA WAY OVER 3" SAND OVER 15 MIL. VAPOR BARRIER OVER 4" AGGREGATES OF 1/2" OR LARGER PRESATURATION TO 110% OF OPTIMUM MOISTURE CONTENT. 90% COMPACTION OR COMPACTED FILL BY SOIL ENGINEER D M I N . PE R S C H E D . H (2)#5 OR (3)#4 REBAR CONT. AT MID WHEN H >32" 4" INTERIOR PARTITION, TYP. 2x P.T D.F SILL PLATE w/ 7 32"Øx312" SHOT PINS @ 32" OC w/ 14 GA PER ICC-ESR 2138 . WASHERS AND FIRST 2 PINS PLACED 6" AND 10" FROM PLATE ENDS CONCRETE SLAB 2x STUDS @ 16" OC 2x P.T D.F SILL PLATE w/ 7 32"Øx312" SHOT PINS @ 32" OC w/ 14 GA PER ICC-ESR 2138 . WASHERS AND FIRST 2 PINS PLACED 6" AND 10" FROM PLATE ENDS CONCRETE SLAB 2x STUDS @ 16" OC BEARING NONE SHEAR WALL NONE BEARING CONCRETE FOOTING SIZE & REBARS PER DETAIL 1/SD1 W PER SCHEDULE PE R S C H E D U L E SE E D E T A I L 1 / S D 1 7 8TYP. REINFORCING DETAILS BEND R= 5(d) FOR #14 THRU #18 LAP SPLICE STIRRUP 6(d ) M I N . TIE OR HOOK 6(d ) M I N . MADE COLD DI M E N S I O N DE T A I L I N G OR 3 " M I N . - ALL BENDS SHALL BE STIRRUP ALT. 135° BENDS - PUT CROSSTIE W/ EACH D= 4(d) FOR #3 THRU #5 D= 6(d) FOR #6 THRU #8 OR 3 " M I N . 12 ( d ) F O R # 6 T H R U # 8 DI M E N S I O N DE T A I L I N G NOTES: CROSSTIE MEMBER BELOW, EXCLUDE CONCRETE IS CAST IN THE THAN 12 INCHES OF FRESH BARS SO PLACED THAT MORE FOR TOP BARS (HORIZONTAL * INCREASE LENGTH BY 30% WIRE TIE END WALLS) D D 48(d) MASONRY (U.N.O.) 48(d) * IN CONCRETE 90° BEND 8(d) R R= 4(d) FOR #9 THRU #11 R= 3(d) FOR #3 THRU #8 2 1/2" MIN.8(d) 180° BEND R12 " 4(d) OR 4" M I N . O R 4" M I N . O R 6(d ) STAIR OR RAMP ON GRADE 2" #3 NOSING TYPICAL SEE ARCH. FOR TREAD AND RISERS 6" MIN . (2)#5 CONT. #4@12 EACH WAY #4@12 RAMP LINE #4@12 1'-6" 2'-0" 1'-2" 1' - 6 " M I N . 1'-6" 2'-0" TYPICAL MANDATORY MINIMUM FORMWORK (UNLESS FULLY FORMED) CLEAN OUT ON DWGS. +2" WIDTH SHOWN LAITANCE AND SCUM HAS SET. REMOVE AFTER CONCRETE NOTE: NOTE: 6" MIN 11/2" MIN. STARTER WALL REQUIRED FOR FOOTINGS CURB OR STARTER WALL BELOW GRADE LC APPLICABLE FORMWORK SPECIFICATIONS 2" PLANKING FOUNDATION CONCRETE MAY BE PLACED DIRECTLY INTO NEAT EXCAVATIONS PROVIDED THE FOUNDATION TRENCH WALLS ARE STABLE AS DETERMINED BY THE ARCHITECT (STRUCTURAL ENGINEER), SUBJECT TO THE APPROVAL OF THE DIVISION OF THE STATE ARCHITECT, IN SUCH CASE. THE MINIMUM FORMWORK SHOWN ON THE DRAWINGS IS MANDATORY TO INSURE CLEAN EXCAVATIONS IMMEDIATELY PRIOR TO AND DURING THE PLACING OF CONCRETE. STARTER WALL REQUIRED FOR ALL MASONRY OR CONCRETE WALLS. STAKES NOT PERMITTED WITHIN FOOTING SECTION. FORMWORK NOT PERMITTED BELOW GRADE UNLESS FULLY FORMED. TYPICAL 6 5 3 9 RETROFIT FOR SHEAR WALL EXIST. SLAB 5 8"Ø ALL-THREADED ROD, 7 8" DRILL BIT w/ SIMP. SET-3G ESR-4057 w/ 3x3x0.229 PLATE WASHER EXISTING SILL PLATE 7" M I N . 2" MIN. FOR 2X4 WALL 3 1/2 " MIN. FOR 2X6 WALL NOTE: SIMPSON SET-3G ESR-4057 SPECIAL INSPECTION REQUIRED EXISTING STUD WALL HOLD DOWN @ EXISTING FOOTING NOTE: SIMPSON SET-3G ESR-4057 SPECIAL INSPECTION REQUIRED HUD2/HDU4/HDU5/ HDU8/HDU11 HOLDOWN w/ SDS2.5 SCREWS ANCHOR BOLT PER SIMPSON CATALOGUE OR 5 8"Ø ALL-THREADED ROD 7 8" DRILL BIT w/ SIMP. SET-3G ESR-4057 SPECIAL INSPECTION REQUIRED @ EXISTING FOOTING EXISTING SLAB & FOOTING 5/8"Ø ALL-THREADED ROD w/ SIMP. SET-3G ESR-4057 2" MIN. FOR 2X4 WALL 3.5 " MIN. FOR 2X6 WALL MI N . l e PE R T A B L E EXISTING SLAB & FOOTING 7/8"Ø ALL-THREADED ROD w/ SIMP. SET-3G ESR-4057 NEW PAD FOOTING AND REINFORCING WHERE OCCURS PER PLAN 3" CL R . SIMPSON HOLDOWN HDU8 HDU2 HDU4 THREADED ROD 5/8"Ø HDU5 5/8"Ø 5/8"Ø 7/8"Ø MIN EMBED (le) 13" 13" 13" 18" 2" MIN. FOR 2X4 WALL 3 1/2 " MIN. FOR 2X6 WALL PAD CONDITION FOR HDU8, HDU11 AND CORNER PAD CONDITION FOR HDU2, HDU4, HDU5 CAPACITY 3075# 4565# 5645# 7870# MIN PAD HDU11 1"Ø 20"11175# 24" SQX24" DEEP 36" SQX24" DEEP MI N . l e PE R T A B L E 24" SQX18" DEEP @ CORNER 24" SQX18" DEEP @ CORNER NEW EXTERIOR FOOTING AT EXISTING SLAB P.T.D.F. SILL PLATE W/ A.B. PER FOUND. PLAN. 24 " M I N . (2) # 4 BARS @ T & B. PER PLAN. 3" B.N. NEW STUD WALL EXSITING 4" THK. CONC. SLAB #4 BARS @ 18" OC w/ 6" INTO E. FOOTING & 24" INTO NEW FOOTING w/ SIMPSON "SET-3G" EPOXY, ICC-ESR-4057. NEW EXTERIOR FOOTING NOTE: SIMPSON SET-3G ESR-4057 SPECIAL INSPECTION REQUIRED CONCRETE CURB CONCRETE PAVING 1- #4 CONT. 8" MI N . CJ W/ 8-16d FACE NAILS LARGER BLOCK (RIPPED TO CORRECT SIZE) FOR GAPS LARGER THAN 1". USE FULL DEPTH BLKG. INSTALL LS70'S WHERE GAP EXCEEDS 1/4". USE NEXT H1'S @ 24" O.C. MAY BE INSTALLED IN LIEU OF A35'S FOR SHEAR TRANSFER. DROP BM. WHERE OCCURS HEADER WHERE OCCURS 2X BEVELED BLOCKING W/E.N. & A35 @ 24" O.C. (SEE ADDITIONAL A35 REQMTS. @ SHEAR WALLS) DBL 2X TOP PLATE 2X STUDS @ 16" O.C. SHEAR PANEL WHERE OCCURS B.N. SEAT CUT ALL RAFTERS. DO NOT OVERCUT. ALT. LOCATION OF BLKG. NOTES: ROOF SHEATHING RR W/ SEAT CUT AT WALL B.N. ROOF RAFTER PERPENDICULAR TO EXT. WALL 30" MAX. 1X6 STARTER BOARD-SHIPLAP AT EXPOSED EAVES 2X ROSA FASICA SIMPSON H2.5A @ 48" O.C. U.N.O. B.N.:8D COMMON NAIL AT 6" O.C. POST & BEAM CONNECTION BM., SEE PLAN POST, SEE PLAN. EQ . EQ . STRAP A CAPACITY - 5600# 2900# MSTA12 EA. SIDE (1) CS16B (2) CS16C OF EACH STRAP OVERALL LENGTH 12" 24" 24" SIMPSON STRAP EACH SIDE OF BEAM TO POST. ALT. TO MSTA12 STRAPS, USE 2X KING STUD EACH SIDE OF BEAM TO POST & NAIL W/ 16d'S @ 16" O.C. TO POST & MIN. (5) 16d'S TO BEAM. CALIF. FRAMING DETAIL 2x VALLEY PLATE W/(3) 16d INTO EACH RAFTER OR TRUSS RAFTER PER PLAN ROOF SHEATHING B.N. 2X6 PURLIN & 2X4 KICKER @ 8'-0" O.C. MAX. TO LIMIT (2)16d TOENAIL RR TO RR. RAFTER PER PLAN 2x4 OR 2X6 RAFTERS @ 24" O.C. MAX. MAX.SPAN: 2x4 = 4'-0" 2x6 = 8'-0" 2x VALLEY PLATE W/(3) 16d INTO EACH RAFTER OR TRUSS 2x RIDGE BOARD W/ DEPTH GREATER THAN JACK RAFTER ADD 2x4 STRUT FROM JACK RAFTER TO RAFTER BELOW TO LIMIT OVER FRAMING RAFTER SPAN TYPICAL TOP PLATE SPLICE ST22 STRAP @ RIDGE OF RAKE WALL 18-16d SINKERS @ SPLICE, STAGGERED DO NOT SPLIT TOP PLATE WITH SPLICE NAILING, SEE TABLE BELOW. STUDS @ 16" O.C. 2-16d FROM TOP PLATE TO BOTTOM PLATE OVER EACH STUD 2-16d FROM PLATE TO EA. STUD 2-2X TOP PLATE 4' NOTE: SPLICE REQUIRED AT ALL PLATE BREAKS AND ALSO AT CHANNELS FOR INTERSECTING WALLS AT ANY EXTERIOR WALL, BEARING WALL, OR SHEAR WALL NO. OF 16d SINKER MIN. PLATE LAP ALT. STRAP w/ 16d SINKER ST22 ST6224 ST6236 MST37 MSTC52 CMST12x72" 8 FT. 42 GF 36 8 FT.8 FT. 32 ED 24 6 FT.6 FT. 22 CB 16 4 FT. 10 A 4 FT. MST60 TYPICAL STUD WALL FRAMING AT OPENING DETAIL (2)10d TOE 16d @ 12"o.c. WIDER THAN 6'-0") TRIMMER AT OPENING 2x TRIMMER (2)2x U.N.O. SILL ~P THAN 4'-0") SILL AT OPENING WIDER WHERE OCCURS (2)2x 2x WINDOW SILL SEE PLAN POST AT HOLDOWNS DOUBLE STUDS OR 2x STUDS @ 16"o.c. TOP AND BOTTOM 6'-0") W/ SIMPSON A34 OPENING WIDER THAN (2)2x THRU STUDS AT (1)2x THRU STUD (USE HEADER DEPTH) OF ADDITIONAL (2)16d FOR EA. 2" (2)16d MIN. (ADD THAN 8'-0" OPENING WIDER SIMPSON A34 AT NAILS STAGGER DETAILS SEE CBC, TABLE 25Q, OR FOR BALANCE OF NAILING, U.N.O. ON PLANS) OPENING HEADER SCHEDULE WIDTH 10'-0" 12'-0" 8'-0" 6'-0" 4'-0" MAX. VERTICAL AND @ 8'-0"o.c. STOPS AT CEILING PROVIDE 2x FIRE NOTE: STUD WIDTH WIDTH SAME AS BEARING 10" 12" NON-BEARING 8" 6" 4" 12" 14" 8" 10" 6" MIN. NOMINAL HEADER ''D'' TO 6'-0" ONLY) (AT OPENINGS UP BUILT-UPSOLID '' D ' ' DE P T H HD R UP PER SCHEDULE HEADER (SOLID, BUILT- (2)2x TOP ~PS EA. SIDE STAGGER w/ 16d @ 12"o.c. CONT. PLYWD. SHIM 2x EA. SIDE ANDNOTE: GABLE END WALL ROOF SHEATHING ROOF RAFTER PER PLAN CEILING JOIST PER PLAN #SHEAR PANEL SEE PLAN E.N B.N B.N STUD WALL DBL TOP PLATE CRIPPLE WALL SIMPSON LTP4 PER SHEAR WALL SCHEDULE SIMPSON A35 PER SHEAR WALL SCHEDULE 2X4 FLAT OUTRIGGER @ 24" O.C. 2X FASCIA BOARD (2) 16d's 2X BLOCKING @ 24" O.C. E.N B.N 10 11 12 13 14 15 1- #4 CONT. (E) SLAB MA T C H ( E ) 6" M I N . E.N. 10" L. #3 DOWELS @ 18" O.C. EMDEB 4" w/ SIMPSON SET-XP ICC ESR 2508 w/ NO SPECIAL INSPECTION ROUGHEN (E) SURFACE AT (N) CURB STUCCO SCREED SHR PANEL PER PLAN 6" EM B . M I N . 2x STUDS @ 16" O/C MIN. 8" MI N 2x P.T.D.F. SILL PLATE, 5 8"Ø ALL-THREADED ROD, 7 8" DRILL BIT @ 16" O.C. w/ SIMP. SET-3G EPOXY, ICC-ESR-4057 TO (E) FOOTING, w/ 3x3x0.229 PLATE WASHER (N)CONCRETE CURB FILL OUT PER ARCH. (N)CONC. CURB AT WALL 6" MIN. (E) FOOTING ASSUMED 12" X12" , VERIFY ON FIELD. 1 1 NEW FOOTING TO EXISTING FOOTING NEW EXISTING 24" EXISTING SLAB & FOOTING (2)#4 BARS @ TOP & BOTT. w/ 6" INTO E. FOOTING w/ SIMPSON SET-3G ESR-4057 NEW SLAB & FOOTING EXISTING FOOTING 12" X12 ", VERIFY ON FIELD 6" NEW EXISTING 24" EXISTING SLAB & FOOTING. (2)#4 BARS @ TOP & BOTT. w/ 6" INTO E. FOOTING w/ SIMPSON SIMP. SET-3G ESR-40576" NOTE: SIMPSON SET-3G EPOXY ESR-4057 SPECIAL INSPECTION REQUIRED NEW SLAB & FOOTING 16 1 02/06/26 5 4 3 1 2 R E V I S I O N 11122 BIXLER CIR., PHONE: 657-820-6210 EMAIL: INFO@PBDINC.ORG GARDEN GROVE, CA92840 PROFESSIONAL BUILDING DESIGNS, INC. THIS DRAWING AND DESIGN CONCEPTS ARE PROPRIETARY TO PBD, INC. THE DRAWING OR DESIGN CONCEPTS SHALL NOT BE USED OR REPRODUCED IN THE PART OR IN WHOLE WITHOUT THE WRITTEN PERMISSION BY PBD, INC. ARCHITECTURAL - STRUCTURAL MECHANICAL - ELECTRICAL - PLUMBING RESIDENTIAL - COMMERCIAL - INDUSTRIAL ON TIME - ON BUDGET - PROFESSIONAL WORK ONE STOP SOLUTION PBD SHEET NO.: DRAW BY: DUY NGUYEN PLOTE DATE: JOB NO.: 25655 C 69546 Exp: 06/30/26 TUNG THANH VO C I V I LSTATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER 11/20/2025 GA R A G E C O N V E R S I O N T O A D U RE S I D E N T I A L P R O J E C T F O R Pr o j e c t A d d r e s s : 2 1 2 9 N H a t h a w a y S t , S a n t a A n a , C A 9 2 7 0 5 DATE BY T24-0 TITLE 24 MANDATORY MEASURES SUMMARY 12/08/25 5 4 3 1 2 R E V I S I O N 11122 BIXLER CIR., PHONE: 657-820-6210 EMAIL: INFO@PBDINC.ORG GARDEN GROVE, CA92840 PROFESSIONAL BUILDING DESIGNS, INC. THIS DRAWING AND DESIGN CONCEPTS ARE PROPRIETARY TO PBD, INC. THE DRAWING OR DESIGN CONCEPTS SHALL NOT BE USED OR REPRODUCED IN THE PART OR IN WHOLE WITHOUT THE WRITTEN PERMISSION BY PBD, INC. ARCHITECTURAL - STRUCTURAL MECHANICAL - ELECTRICAL - PLUMBING RESIDENTIAL - COMMERCIAL - INDUSTRIAL ON TIME - ON BUDGET - PROFESSIONAL WORK ONE STOP SOLUTION PBD SHEET NO.: DRAW BY: DUY NGUYEN PLOTE DATE: JOB NO.: 25655 C 69546 Exp: 06/30/26 TUNG THANH VO C I V I LSTATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER 11/20/2025 GA R A G E C O N V E R S I O N T O A D U RE S I D E N T I A L P R O J E C T F O R Pr o j e c t A d d r e s s : 2 1 2 9 N H a t h a w a y S t , S a n t a A n a , C A 9 2 7 0 5 DATE BY T24-1 TITLE 24 GARAGE CONVERTION TO ADU 12/08/25 CERTIFICATE NO. 100035 SANTA ANA UNIFIED SCHOOL DISTRICT SCHOOL FACILITIES FEE CERTIFICATION OF COMPLIANCE AND RECEIPT FOR PAYMENT FOR Project Number:PRJ-5389413 Project Request ID:XHTWGYA24K Request Contact:Araceli Maciel (OTHER) Job Location / Address: 2129 N Hathaway St, Santa Ana, CA 92705 Permit Issuing Office: City of Santa Ana This is to certify that all fees due to the Santa Ana Unified School District under Provision of Government Code Section 65995 as a prerequisite to the issuance of a Building Permit have been received, based on the above referenced information, this Certification is hereby Executed. PMT-902659 Address Development Type Construction Type Square Feet 2129 N Hathaway St #2, Santa Ana, CA 92705 Residential Accessory Dwelling Unit (ADU) 399 Parcel 396-183-10 Tract 5910 Permit Number 101125998 Plan Check Number 101125998 902659-Residential Accessory Dwelling Unit (ADU) fees as required in the amount of:$2,062.83 ($5.17 [Rate] x 399 [Square Footage])Note: Fee not included in developer fees total due to square footage requirement not being met. Developer Fees Paid:$0.00 Notes: Exempt less than 500 sq feet Yvette Miranda School District Representative Date: 02/20/2026 NOTICE OF 90-DAY PERIOD FOR PROTEST OF FEES Pursuant to Section 66020 of the California Government Code and other applicable law, you have a period of ninety (90) days from the date of payment of school fees, mitigation payments or other extractions to protest the validity thereof. This ninety (90) day period commences upon such payment of performance of any other requirement as provided in Section 66020. Any such protest must be in writing and received by the Santa Ana Unified School District within ninety (90) calendar days of the date of the School District Certification above.