HomeMy WebLinkAbout2222 S Bristol St & Unit A - PlanPROJECT TITLE / ADDRESS:
Dr. KALANTARI DENTAL OFFICE
2222 S BRISTOL ST. SUITE A,
SANTA ANA, CA 92704
PROJECT VALUATION:
$198,662
PROJECT DESCRIPTION: TENANT IMPROVEMENT, EXTERIOR REMODEL AND
SUITE MERGE OF EXISTING COMMERCIAL OFFICE BUILDING
OCCUPANCY:
B (DENTAL OFFICE - NO CHANGE OF OCCUPANCY REQ.)
BASE BLDG. CONSTRUCTION TYPE:
EXISTING BUILDING TYPE V-B (FIRE-SPRINKLERED).
STORIES:
1
PROPERTY INFORMATION:
ZONING: C2 (GENERAL COMMERCIAL)
APN: 408-471-18
FLOOR AREA OF SUITE:
SUITE A:
SUITE B:
NEW SUITE A TOTAL:2900 S.F.
EXIST. BLDG. SHELL (UNCHANGED): 4419 S.F. APPROX
OCCUPANCY LOAD:
TOTAL: 37 (36.4)
OFFICE (2615 S.F.): 17.4 - (BUSINESS: 1:150 GROSS)
WAITING (285 S.F.): 19 - (WAITING: 1:50 GROSS)
EXITS:
MAX. COMMON PATH OF EGRESS TRAVEL DISTANCE: 100'-0" (PER CBC TABLE
1006.2.1)
EXITS REQUIRED:1
EXITS PROVIDED:2
CALGREEN:
PER 2022 CGBSC 301.3, BUILDING ALTERATIONS WITH A PERMIT VALUATION OF
LESS THAN $200,000 SHALL BE EXEMPT. PER 301.3.1, EXISTING NONCOMPLIANT
PLUMBING FIXTURES SHALL BE BROUGHT INTO COMPLIANCE.
PROJECT DIRECTORY PROJECT DATA
A-0.0
COVER SHEET
GENERAL NOTES
SHEET INDEX
TYP Typical
N North
EML Expanded Metal Lath
P LAM Plastic Laminate
PC Precast Concrete
OSB Oriented Strand Board
OD Overflow Drain/ Outside
FO Finished opening
FR Fire Resistant
FTG Footing
FOS Face of Stud
FOF Face of Finish
FLUOR Fluorescent
FLR Floor
FIN Finish(ed)
FDN Foundation
FD Floor Drain
FAI Fresh Air Inlet
EXT Exterior
EXP Expansion
EQUIP Equipment
EQ Equal
PL Plate
OVHD Overhead
OPP Opposite
OPNG Opening
Diameter
OC On Center
NR Non-rated
NTS Not To Scale
NOM Nominal
NIC Not In Contract
WWF Welded Wire Fabric
VWC Vinyl Wall Covering
WP Waterproofing
WH Water Heater
WD Wood
WC Water Closet
W/O Without
W/ With
VIF Verify In Field
VERT Vertical
VB Vapor Barrier
VT Vinyl Tile
U/S Underside
HVAC Heating Vent & Air
HDCP Handicapped
GMMU Glass Mesh Mortar Unit
GFRC Glass Fiber Reinforced
GC General Contractor
ALT Alternative
CONST Construction
DPM Damp-Proof Membrane
EMER Emergency
ELEC Electrical
ELEV Elevation
EA Each
E Existing
DWG Drawing
DS Downspout
DR Door
DN Down
DIM Dimension
DIFF Diffuser
DET Detail
DBL Double
CT Ceramic Tile
CS Countersunk
CPT Carpet
CONTR Contractor
CONT Continuous
MTL Metal
MISC Miscellaneous
MIN Minimum
MH Manhole
Fiberboard
MDF Medium Density
MANUF Manufacturer
MECH Mechanical
MAX Maximum
MATL Material
LTWT Lightweight
LL Live Load
LHS Left Hand Side
LAV Lavatory
LAM Laminated
JNT Joint
JST Joist
JAN Janitor
CMU Concrete Masonry Unit
BUR Built-up Roofing
BM Beam
COL Column
CLG Ceiling
CI Cast Iron
CHAN Channel
BTWN Between
BOT Bottom
B M Benchmark
BLKG Blocking
BLK Block
BLDG Building
BIT Bitumen
BD Board
ASPH Asphalt
ARCH Architect
ANOD Anodized
ALUM Aluminum
HM Hollow Metal
INV Invert
INT Interior
INSUL Insulation
ID Inside Diameter
Conditioning
HTG Heating
HT Height
HR Hour
HORIZ Horizontal
HDWR Hardware
HC Hollow Core
HB Hose Bib
GYP Gypsum
GL Glass
Concrete
AFF Above Finished Floor
ABBREVIATIONS
AGG Aggregate
AB Anchor Bolt
GALV Galvanized
GA Gauge
SC Solid Core
TOC Top of Concrete
T & G Tongue and Groove
SPECS Specifications
TRANSF Transformer
T-STAT Thermostat
TOW Top of Wall
TOS Top of Steel
TOM Top of Masonry
TJ Tooled Joint
TEMP Tempered
TEL Telephone
SUSP Suspended
STRUC Structural
STL Steel
STD Standard
SS Stainless Steel
SHTG Sheathing
SIM Similar
SECT Section
SD Storm Drain
RE: Refer/ Reference
PSI Pounds per Square Inch
PSF Pounds per Square Foot
REFL Reflected
SB Splash Block
RO Rough Opening
RM Room
RHS Right Hand Side
RF Roof
REV Revision
RET Retaining
REQ'D Required
REINF Reinforcing
RD Roof Drain
RA Return Air
R Radius
QTY Quantity
QT Quarry Tile
PT Post Tensioned
PR Pair
PNL Panel
PLYWD Plywood
Dr. Kalantari Dental Office
DENTAL OFFICE TENANT IMPROVEMENT PROJECT
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
SHEET NO.
2509
REVISIONS:
5/30/2025DATE:
PROJECT NO.
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
S
a
n
t
a
A
n
a
,
C
A
9
2
7
0
4
SITE LOCATION MAP 2. ALL NEW DOORS SHALL COMPLY WITH CBC 1008 AND 11B-404. DOOR HARDWARE SHALL BE LEVER OR PUSH TYPE, MOUNTED 34" TO 48" ABOVE THE FLOOR, PER CBC SEC. 1008.1.9. ALL
DOORS SHALL BE 3'-0" WIDE MIN.
3. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR INTERIOR DOORS. SUCH PUSH OR PULL EFFORT SHALL BE APPLIED AT RIGHT
ANGLES TO HINGED DOORS. AT REQUIRED FIRE DOORS, MAX. OPERATING EFFORT MAY BE INCREASED TO 15 LBS.
4. PER CBC 11B-302 AND 11B-404.2.5, REGARDLESS OF THE OCCUPANT LOAD, THERE SHALL BE A LEVEL FLOOR OR LANDING ON EACH SIDE OF AN EGRESS DOOR. THE FLOOR OR LANDING
SHALL NOT BE MORE THAN 1/2" LOWER THAN THE THRESHOLD OR THE DOORWAY.
5. THE LOWER 10" OF ALL DOORS SHALL BE SMOOTH AND UNINTERRUPTED TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR
HAZARDOUS CONDITION. NARROW FRAME DOORS MAY USE A 10" HIGH SMOOTH PANEL ON THE PUSH SIDE OF THE DOOR.
6. 2 NEW ALL GENDER RESTROOMS ARE PROVIDED IN THIS BUILDING:
7. WATER-CLOSET / FAUCET CONTROLS SHALL BE OPERABLE WITH ONE HAND AND DO NOT REQUIRE TIGHT GRASPING. PINCHING OR TWISTING OF THE WRIST.
8. LAVATORIES SHALL COMPLY WITH THE FOLLOWING:
a) A MINIMUM OF 30" x 48" CLEAR SPACE IS PROVIDED IN FRONT OF THE LAVATORY .
b) THE CLEAR SPACE BENEATH LAVATORIES IS A MINIMUM OF 29" HIGH x 30" WIDE x 8" DEEP AT THE TOP AND 9" HIGH x 30" WIDE x 17" DEEP AT THE BOTTOM. THE MAXIMUM HEIGHT OF THE
BASIN / COUNTER TOP IS 34" HEIGHT MAX.
c) ALL HOT WATER AND DRAIN PIPES UNDER THE LAVATORY ARE INSULATED.
d) FAUCET CONTROLS HAVE AN OPERATING FORCE OF NOT GREATER THAN 5 POUNDS.
9. FLOORS ARE TO BE SLIP-RESISTANT.
10. GRAB BARS SHALL BE PROVIDED. FASTENERS AND MOUNTING SUPPORT MUST BE ABLE TO WITHSTAND 250 POUNDS POINT LOAD BEARING SHEAR AND TORSION.
11. DOORS TO THE TOILET ROOM SHALL BE IDENTIFIED BY A 12" X 1/4" THICK SIGN WITH ETCHED ALL-GENDER SYMBOL: 12" DIAMETER
CIRCULAR WITH EQUALITERAL TRIANGLE VERTEX POINTING UP.
1. CARRY OUT ALL DEMOLITION WORK INDICATED IN ACCORDANCE WITH STATE AND LOCAL CODES.
2. REMOVE ALL DEBRIS FROM SITE AS WORK PROCEEDS AND DISPOSE OF AS PER CODE AND THE BUILDING MANAGEMENT REQUIREMENTS.
INFORM ARCHITECT IMMEDIATELY IF ANY HAZARDOUS MATERIALS ARE ENCOUNTERED.
3. PROVIDE TEMPORARY BARRICADES AND PROTECT EXISTING FINISHES IN PLACE.
DEMOLITION NOTES
SANITARY FACILITIES
SITE ACCESS
(CBC ACCESSIBILITY STANDARDS SHALL TAKE PRECEDENCE)
1. ACCESSIBLE SIGNAGE SHALL BE PROVIDED AT ALL NEW TOILET FACILITIES AND EXITS. SEE SIGNAGE SCHEDULE. SIGNS TO HAVE RAISED LETTERS PLUS BRAILLE, AND ARE TO BE INSTALLED 48"
MIN. TO 60" MAX. AFF, ADJACENT TO LATCH SIDE OF DOOR.
ACCESSIBILITY NOTES
GENERAL ACCESSIBILITY
DOORS
1. THE BUILDING AND SITE ARE EXISTING AND SHALL BE MADE FULLY ACCESSIBLE.
2. PRIMARY ENTRANCES TO THE BUILDING ARE ON AN ACCESSIBLE ROUTE. GROUND SURFACES ALONG THIS ROUTE, INCLUDING CURB RAMPS ARE ACCESSIBLE.
APPLICABLE CODES
FIRE DEPT. NOTES
A TENANT IMPROVEMENT PROJECT, EXTERIOR REMODEL, & SUITE MERGE
IN AN EXISTING COMMERCIAL BUILDING. THIS FACILITY IS NOT REQUIRED
TO UNDERGO OSHPD REVIEW, NOR WILL THIS PROJECT BE SUBJECT TO
STATE LICENSING (PER CBC 1226). GENERAL ANESTHESIA WILL NOT BE
ADMINISTERED AT THIS FACILITY. NO ORAL SURGERY. THE TENANT
IMPROVEMENT SHALL INCLUDE THE FOLLOWING:
1.SUITE MERGE (SUITE B TO BE DEACTIVATED)
2.NEW INTERIOR NON-LOAD BEARING PARTITION WALLS
3.NEW GYPSUM BOARD AND SUSPENDED CEILING SYSTEMS
4.ALL NEW FINISHES THROUGHOUT
5.ALL NEW PLUMBING FIXTURES AND PIPING
6.HVAC MODIFICATIONS
7.NEW ELECTRICAL & LIGHTING
8.2 NEW ACCESSIBLE ALL GENDER RESTROOMS
9.NEW EXTERIOR STOREFRONT WINDOW/DOOR SYSTEM
10.RE-FINISH OF EXTERIOR SURFACES/ROOF.
11. EXTERIOR SOFFIT MODIFICATIONS
12.NEW CURB RAMPS AND CONCRETE WALKWAY
NO CHANGE TO BUILDING FOOTPRINT OR FAF. NO CHANGE TO
QUANTITY OF PARKING STALLS
SCOPE OF WORK
2022 BUILDING STANDARDS ADMINISTRATIVE CODE, PART 1, TITLE 24 C.C.R.
2022 CALIFORNIA BUILDING CODE (CBC), PART 2, TITLE 24 C.C.R.
2022 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, TITLE 24 C.C.R
2022 CALIFORNIA MECHANICAL CODE (CMC), PART 4, TITLE 24 C.C.R
2022 CALIFORNIA PLUMBING CODE (CPC), PART 5, TITLE 24 C.C.R
2022 CALIFORNIA FIRE CODE (CFC), PART 9, TITLE 24 C.C.R
2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBC), PART 11, TITLE 24 C.C.R
2022 CA ENERGY EFFICIENCY CODE
OWNER:
DR. DANIEL KALANTARI, DDS/DMD
2222 S BRISTOL ST,
SANTA ANA, CA 92704
(949) 307 1773
ARCHITECT:
SAUNDERS + WIANT ARCHITECTS, INC.
2700 WEST COAST HIGHWAY, #200,
NEWPORT BEACH, CA. 92663
(949) 721 0730
MECHANICAL/ELECTRICAL/PLUMBING:
ABSOLUTE CONSULTING ENGINEERS
3839 BIRCH STREET
NEWPORT BEACH, CA 92660
(949)852 8700
1.EXTERIOR SIGNAGE
2.FIRE SPRINKLERS
DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE
REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL REVIEW
THEM AND FORWARD THEM TO THE BUILDING OFFICIAL WITH A NOTATION
INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED
AND FOUND TO BE IN GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING.
THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL
FIRE SPRINKLER DRAWINGS SHALL BE SUBMITTED AND APPROVED BY THE ORANGE
COUNTY FIRE AUTHORITY (OCFA) PRIOR TO THE FINAL OF THE BUILDING PERMIT.
DEFERRED SUBMITTALS
1. ALL WORK SHALL BE PER STATE, FEDERAL & LOCAL CODES, ORDINANCES, ETC. INCL.THE 2022 EDITION OF THE CALIFORNIA BUILDING CODE
(TITLE 24) WHICH ADOPTS THE 2022 CBC, CMC, AND CPC AND THE 2022 CEC.
1a. ALL WORK SHALL BE PER 2022 CALIFORNIA ENERGY EFFICIENCY STANDARDS AS ADOPTED BY THE CITY.
2. EACH SUB-CONTRACTOR SHALL VISIT THE SITE, VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS. NOTIFY THE ARCHITECT OF ANY
DISCREPANCIES OR INCONSISTENCIES FOUND. DO NOT SCALE DRAWINGS.
3. CONSTRUCTION, DEMOLITION AND REMODEL SHALL COMPLY WITH C.F.C. CHAPTERS 11 AND 33. CONTRACTOR SHALL PATCH & REPAIR
NEIGHBORING FINISHES IF DAMAGED DURING DEMOLITION OR CONSTRUCTION.
4. THE CONTRACTOR SHALL DISPOSE OF ALL DEMOLITION AND CONSTRUCTION DEBRIS OFF SITE AND IN AN APPROVED MANNER, ACCORDING TO
STATE AND CITY CODES.
5. ALL EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. NO DEADBOLTS,
SLIDING BOLTS, ETC. PROVIDE SELF RELEASING LOCKING DEVICES ON EXIT DOORS. EXIT DOORS SHALL SWING OPEN IN DIRECTION OF EXIT TRAVEL.
6. WHERE NO CONSTRUCTION DETAILS ARE SHOWN OR NOTED FOR ANY PART OF THE WORK TO BE DONE, DETAILS SHALL BE SAME AS FOR OTHER
SIMILAR WORK.
7. FIRE EXTINGUISHERS SHALL BE PROVIDED PER C.F.C. SECTION 906. EXTINGUISHERS TO BE TYPE 2A10BC WITH CURRENT STATE FIRE MARSHALL
SERVICE TAG, MOUNTED IN VISIBLE LOCATIONS, NOT MORE THAN 75' WALKING DISTANCE FROM ANY POINT IN THE SPACE. UNITS TO BE INSTALLED
IN SEMI-RECESSED WALL CABINETS.
8. ALL POWER ACTUATED PINS/ANCHORS SHALL BE "RAMSET" #2330 AT 32" O.C. FOR INTERIOR, NON-LOAD BEARING PARTITIONS PER ICC ESR-1799.
9. WALL, FLOOR AND CEILING MATERIALS SHALL NOT EXCEED THE FLAME SPREAD CLASSIFICATIONS IN CBC TABLE 803.11.
10. IF REQUESTED BY INSPECTOR, CONTRACTOR TO POST OCCUPANT LOAD SIGN COMPLYING WITH C.F.C. SEC. 1003 AND C.B.C. SEC. 1004.3.
POST IN WAITING AREA.
12. ENSURE ALL EXIT AISLEWAYS AND CORRIDORS ARE MAINTAINED AT 36" MINIMUM CLEAR WIDTH IN OFFICE AREA.
14. ENSURE ALL FINISHES ARE MAINTAINED IN FIRE RETARDANT CONDITION. ALL NEW FINISHES SHALL BE PER CHAPTER 8 (TABLE 803.11) OF THE CBC,
CLASS III, FLAME SPREAD INDEX 200 MAX. (INCLUDES CARPETS, ETC.)
16. IF REQUESTED A STATEMENT IN WRITING SHALL BE GIVEN TO THE BUILDING OFFICIAL, STATING THAT THE ARCHITECT / ENGINEER SITE
OBSERVATION AND SITE VISITS HAVE BEEN MADE AND WHETHER OR NOT ANY OBSERVED DEFICIENCIES HAVE BEEN CORRECTED TO CONFORM TO
THE APPROVED PLANS AND SPECIFICATIONS.
17. GENERAL CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED PERMITS.
18. PROTECT IN PLACE ALL EXISTING FINISHES WHICH ARE TO REMAIN. REPAIR OR REPLACE ANY SUCH FINISHES DAMAGED DURING
CONSTRUCTION.
19. REFER TO SPECIFICATIONS ON SHEET A-5 FOR ADDITIONAL STANDARDS AND REQUIREMENTS.
20. NO HAZARDOUS MATERIALS STORED ON SITE EXCEED QUANTITIES LISTED IN CBC TABLE 307.1(1) AND 307.1(2).
21. EXIT SIGNS SHALL BE READILY VISIBLE FROM ANY DIRECTION OF APPROACH AND SHALL CLEARLY INDICATE THE DIRECTION OF TRAVEL. NO
POINT SHALL BE MORE THAN 100 FEET (30480 MM) FROM THE NEAREST VISIBLE SIGN. ALL SIGNS SHALL BE ILLUMINATED AND CONNECTED TO AN
EMERGENCY ELECTRICAL SYSTEM. (CBC 1008.2.1, 1008.3)
22. CONSTRUCTION SHALL BE SUPERVISED AS REQUIRED BY TENANT/LANDLORD LEASE REQUIREMENTS. WHERE REQUIRED BY THESE DOCUMENTS,
PROVIDE CONTINUOUS INSPECTION OF THE WORK. THE DUTIES OF THE INSPECTOR ARE DEFINED IN SECTION 4-342 PART 1, TITLE 24, CCR; CLASS 3.
1. BUILDINGS UNDERGOING CONSTRUCTION, ALTERATION OR DEMOLITION SHALL BE IN ACCORDANCE WITH CALIFORNIA FIRE CODE (CFC).
2. AT LEAST ONE FIRE EXTINGUISHER WITH A MINIMUM RATING OF 2-A-10B:C SHALL BE PROVIDED WITHIN 75 FEET MAXIMUM TRAVEL DISTANCE FOR
EACH 6,000 SQUARE FEET OR PORTION THEREOF ON EACH FLOOR. (CFC 906, CAL. CODE REGS., TIT. 19, 3.29)
3. IF REQUIRED, COMPLETE PLANS AND SPECIFICATIONS FOR FIRE ALARM SYSTEMS; FIRE-EXTINGUISHING SYSTEMS AND OTHER FIRE-PROTECTION
SYSTEMS AND APPURTENANCES THERETO SHALL BE SUBMITTED TO FIRE AND LIFE SAFETY FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. [CFC
901.2]
4. ALL VALVES CONTROLLING THE WATER SUPPLY FOR AUTOMATIC SPRINKLER SYSTEMS AND WATER-FLOW SWITCHES ON ALL SPRINKLER SYSTEMS
SHALL BE ELECTRICALLY MONITORED WHERE THE NUMBER OF SPRINKLERS IS 20 OR MORE. (CBC 903.4, CFC 1003.3.1)
5. NEW AND EXISTING BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION
PLACE IN A POSITION THAT IS PLAINLY LEGIBLE AND VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY, CONTRASTING WITH THEIR
BACKGROUND. NUMBERS SHALL BE A MINIMUM OF 4 INCHES HIGH WITH A MINIMUM STROKE OF 0.5 INCHES. WHERE ACCESS IS BY MEANS OF A
PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED
TO IDENTIFY THE STRUCTURE. CFC 505.1
6. WHERE REQUIRED TO BE FLAME RESISTANT, DECORATIVE MATERIALS SHALL BE TESTED BY AN APPROVED AGENCY AND MEET FLAME
PROPOGATION PERFORMANCE CRITERIA OF NFPA 701, OR SUCH MATERIALS SHALL BE NONCOMBUSTIBLE. REPORTS OF TEST RESULTS SHALL BE
PREPARED IN ACCORDANCE WITH NFPA 701 AND FURNISHED TO THE FIRE CODE OFFICIAL UPON REQUEST. CFC 807.2.
7. PER CFC 807.4: ACCEPTANCE CRITERIA AND REPORTS. WHERE REQUIRED TO EXHIBIT IMPROVED FIRE PERFORMANCE, CURTAINS, DRAPERIES,
FABRIC HANGINGS AND OTHER SIMILAR COMBUSTIBLE DECOATIVE MATERIALS SUSPENDED FROM WALLS OR CEILINGS SHALL BE FLAME RESISTANT
IN ACCORDANCE WITH THE PROVISIONS SET FORTH IN CCR, TITLE 19, DIVISION 1, CHAPTER 8. REPORTS OF TEST RESULTS SHALL BE PREPARED IN
ACCORDANCE WITH THE TEST METHOD USED AND FURNISHED TO THE FIRE CODE OFFICIAL UPON REQUEST.
THE SITE N
A-0.0 COVER SHEET
A-0.1 SITE PLAN
A-1.0 FLOOR PLAN
A-1.1 DIMENSION PLAN
A-1.2 DEMOLITION PLAN
A-1.3 ROOF PLAN
A-1.4 EGRESS PLAN
A-2.0 REFLECTED CEILING PLAN
A-3.0 CABINET ELEVATIONS
A-3.1 CABINET/INTERIOR ELEVATIONS
A-3.2 RESTROOM ELEVATIONS
A-3.3 EXTERIOR ELEVATIONS
A-4.0 SCHEDULES
A-5.0 SPECIFICATIONS
A-5.1 SPECIFICATIONS
A-6.0 DETAILS
A-6.1 DETAILS
A-6.2 DETAILS
A-6.3 EXTERIOR DETAILS
A-7.0 ACCESSIBILITY DETAILS
E-1.0 GEN. NOTES, LEGEND
E-1.1 LIGHT FIXTURE SCHED, LIGHT CONTR. PANEL
E-1.2 PANEL SCHEDULES
E-1.3 PANEL SCHEDULES
E-2.0 LIGHTING PLAN
E-3.0 POWER PLAN
E-4.0 LIGHTING TITLE 24
E-4.1 LIGHTING TITLE 24
E-4.2 LIGHTING TITLE 24
E-4.3 LIGHTING TITLE 24
E-4.4 LIGHTING TITLE 24
E-5.0 LIGHTING TITLE 24 (OUTDOOR)
E-5.1 LIGHTING TITLE 24 (OUTDOOR)
E-5.2 LIGHTING TITLE 24 (OUTDOOR)
M-1.0 GEN. NOTES, LEGEND
M-1.1 SCHEDULES, TABLES, DIAGRAM DETAILS
M-1.2 DUCTS, AIR DISTRIBUTION DETAILS, SPECIFICATIONS
M-2.0 MECHANICAL PLAN
M-3.0 DETAILS
M-4.0 MECHANICAL TITLE 24
M-4.1 MECHANICAL TITLE 24
P-1.0 GEN. NOTES, LEGENDS, SPECIFICATIONS
P-2.0 PLUMBING PLAN
P-3.0 PLUMBING PLAN
P-3.1 PLUMBING PLAN
P-3.2 PLUMBING SITE PLAN
P-4.0 DETAILS
P-4.1 DETAILS
P-5.0 PLUMBING TITLE 24
P-5.1 PLUMBING TITLE 24
P-5.2 PLUMBING TITLE 24 3. VAN ACCESSIBLE PARKING SPACE TO BE PROVIDED,
LOCATED ON SITE AT THE PARKING LOT SERVING THIS BUILDING.
ACCESSIBLE SPACES TO COMPLY IN REGARD TO QUANTITY,
SPACE, STRIPING, SIGNAGE, AND CURB RAMPS.
4. TEXT "MIN. FINE $250.00" ON SIGNS AT STALLS (MIN. 1" HIGH
LETTERS AND A PERMANENT PART OF THE SIGN). ENSURE SIGN
MIN. 6'-8" A.F.F.
5. ACCESS AISLES HAVE BEEN PAINTED PER 11B-502.3.
6. STRIPING: PERIMETER SHALL BE BLUE COLOR (105090) PER FED.
STD. 595B AND CROSSHATCHING TO BE WHITE.
7. DOORS ALONG PEDESTRIAN PATH OF TRAVEL ARE REQUIRED
TO MEET ALL REQUIREMENTS FOR EXITS DOORS, AS FOLLOWS:
A. 36"-48" LEAF WIDTH
B. WHERE PANIC HARDWARE IS USED, MOUNT ABOVE 36"
A.F.F. OR SHOW MIN. 32" CLEAR WIDTH WHEN GATE IS
OPEN 90 DEGREES.
C. MAX. 5LB. OPERATING PRESSURE
D. BOTTOM 10" OF DOORS TO BE SMOOTH FROM SIDE TO
SIDE
E. LEVER OR ACCESSIBLE PULL FROM PULL SIDE OF DOOR
F. REQUIRED MANEUVERING CLEARANCES PER FIG.
11B-404.2.4.1
G. MIN. HEADROOM 6'-8"
H. NO CANE BOLTS OR PADLOCKS ON DOORS WITH
PANIC HARDWARE
A PLANCHECK
REVISIONS 10-15-25
PLUMBING
PER 2022 CPC 422.2 EXCEPTION 3, ANY BUSINESS OR MERCANTILE WITH OCCUPANT LOAD OF 50 OR LESS IS
ALLOWED TO HAVE 1 ALL GENDER RESTROOM. THERE ARE 2 FULLY ACCESSIBLE ALL GENDER RESTROOMS IN THIS
SUITE.
CPC TABLE 422.1 - MINIMUM PLUMBING FACILITIES
ACTUAL S.F.:2900 S.F.
ADJUSTED:2193 S.F. (ACCESSORY AREAS EXCLUDED (HALLWAYS, RESTROOMS, ETC.) PER CPC 422.1; TABLE
4-1 [DSA-SS, CPC 2022] EXCEPTION)
- OFFICE: 2193 S.F. (1:150)[15 OCC.]
OCCUPANCY:15 OCCUPANTS (8 MALE, 8 FEMALE) (PER TABLE 4-1, OCCUPANT LOAD FACTOR)
REQUIRED FIXTURES:
MALE:FEMALE:PROVIDED:
WATER CLOSET:1 (1-50)2 (16-30)2 (ALL GENDER FACILITIES)
LAVATORIES:1 (1-75)2 (51-100)2 (ALL GENDER FACILITIES)
PER CPC 415: DRINKING FOUNTAINS SHALL NOT BE REQUIRED FOR AN OCCUPANT LOAD OF 30 OR LESS.
B PLANCHECK
REVISIONS 12-10-25
NO PARKING
9'-0"
MIN.
8'-0"
MIN.
18
'
-
0
"
MI
N
.
3'-0"
22
'
-
0
"
23'-2"
26'-10"
8'-6"
(TYP.)
16
'
-
0
"
(T
Y
P
.
)
9'
-
1
0
1
/
2
"
6"
16
'
-
0
"
(T
Y
P
.
)
9'-0"
(TYP.)
4'
-
6
"
NO PARKING
140'-0"
12
8
'
-
0
"
4'-0"
59
'
-
1
1
1
/
2
"
27'-2"
6"
6"
0"
0"
17'-6"
6'
-
0
"
6'
-
0
"
4'
-
0
"
0"
0"
NO PARKING
9'-0"
MIN.
8'-0"
MIN.
18
'
-
0
"
MI
N
.
3'-0"
22
'
-
0
"
8'-6"
(TYP.)
16
'
-
0
"
(T
Y
P
.
)
9'
-
1
0
1
/
2
"
6"
4'-0"
6"
0"
17'-6"
6'
-
0
"
6'
-
0
"
4'
-
0
"
0"
0"
NEW CONCRETE SLAB AND
CURB SHALL BE STABLE, FIRM, &
SLIP RESISTANT PER CBC
11B-302.1
PER 11B-403.3 RUNNING SLOPE
OF WALKING SURFACES SHALL
NOT BE STEEPER THAT 1:20 -
CROSS SLOPE NO STEEPER
THAN 1:48
PROVIDE 48" CLEAR WIDTH PER
CBC 11B-403.5.1 EXCEPTION 3 -
CHANGE IN LEVEL BETWEEN 6"
CURB AND CONCRETE PAD
SHALL COMPLY WITH 11B-303
PER 11B-307.2 OBJECTS WITH
LEADING EDGES MORE THAN
27" AND NOT MORE THAN 80"
ABOVE THE F.F. SHALL
PROTRUDE 4" MAX. HORIZ. INTO
THE CIRCULATION PATH
PER 11B-307.4 VERTICAL
CLEARANCES ALONG THE PATH
OF TRAVEL ARE 80" HIGH MIN.
NO GUARDRAILS OR OTHER
BARRIERS PRESENT ALONG
PATH.
SITE PLAN
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
SHEET NO.
2509
REVISIONS:
5/30/2025DATE:
PROJECT NO.
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
S
a
n
t
a
A
n
a
,
C
A
9
2
7
0
4
A-0.1
1/8" = 1'-0"
SITE PLAN
0.1
A
STORM WATER POLLUTION PREVENTION NOTES
STORM WATER POLLUTION PREVENTION DEVICES AND PRACTICES SHALL BE INSTALLED AND/OR INSTITUTED AS NECESSARY TO ENSURE COMPLIANCE TO THE CITY WATER QUALITY STANDARDS
AND ANY EROSION CONTROL PLAN ASSOCIATED WITH THIS PROJECT. ALL SUCH DEVICES AND PRACTICES SHALL BE MAINTAINED, INSPECTED AND/OR MONITORED TO ENSURE ADEQUACY
AND PROPER FUNCTION THROUGHOUT THE DURATION OF THE CONSTRUCTION PROJECT.
COMPLIANCE TO THE WATER QUALITY STANDARDS ON ANY EROSION CONTROL PLAN ASSOCIATED WITH THIS PROJECT INCLUDES, BUT IS NOT LIMITED TO THE FOLLOWING REQUIREMENTS:
1.EFFECTIVE COMBINATION OF EROSION AND SEDIMENT CONTROL BMPS SHALL BE IMPLEMENTED TO PROTECT THE EXPOSED PORTIONS OF THE SITE FROM EROSION AND TO PREVENT SEDIMENT
DISCHARGES.
2.SEDIMENTS AND OTHER POLLUTANTS SHALL BE RETAINED ON SITE UNTIL PROPERLY DISPOSED OF, AND MAY NOT BE TRANSPORTED FROM THE SITE VIA SHEET FLOW, SWALES, AREA DRAINS,
NATURAL DRAINAGE COURSES OR WIND.
3.STOCKPILES OF EARTH AND OTHER CONSTRUCTION-RELATED MATERIALS SHALL BE PROTECTED FROM BEING TRANSPORTED FROM THE SITE BY THE FORCES OF WIND AND WATER FLOW.
4.FUELS, OILS, SOLVENTS, AND OTHER TOXIC MATERIALS SHALL BE STORED IN ACCORDANCE WITH THEIR LISTING AND ARE NOT TO CONTAMINATE THE SOIL AND SURFACE WATERS. ALL
APPROVED STORAGE CONTAINERS ARE TO BE PROTECTED FROM THE WEATHER. SPILLS MUST BE CLEANED UP IMMEDIATELY AND DISPOSED OF IN A PROPER MANNER. SPILLS MAY NOT BE
WASHED INTO THE DRAINAGE SYSTEM, NOR BE ALLOWED TO SETTLE OR INFILTRATE INTO SOIL.
5.EXCESS OR WASTE CONCRETE MAY NOT BE WASHED INTO THE PUBLIC WAY OR ANY OTHER DRAINAGE SYSTEM. PROVISIONS SHALL BE MADE TO RETAIN CONCRETE WASTES ON SITE UNTIL
THEY CAN BE DISPOSED OF AS SOLID WASTES.
6.TRASH AND CONSTRUCTION SOLID WASTES SHALL BE DEPOSITED INTO A COVERED RECEPTACLE TO PREVENT CONTAMINATION OF RAINWATER AND DISPERSAL BY WIND.
7.SEDIMENTS AND OTHER MATERIALS MAY NOT BE TRACKED FROM THE SITE BY VEHICULAR TRAFFIC. THE CONSTRUCTION ENTRANCE ROADWAYS MUST BE STABILIZED SO AS TO INHIBIT
SEDIMENTS FROM BEING DEPOSITED INTO THE PUBLIC WAY. ACCIDENTAL DEPOSITS SHALL BE SWEPT UP IMMEDIATELY AND MAY NOT BE WASHED DOWN BY RAIN OR OTHER MEANS.
8.STORM WATER POLLUTION PREVENTION DEVICES AND /OR PRACTICES SHALL BE MODIFIED AS NEEDED AS THE PROJECT PROGRESSES TO ENSURE EFFECTIVENESS.
ADDITIONAL ENVIRONMENTAL REQUIREMENTS
AT LEAST 75% OF CONSTRUCTION WASTE MATERIALS ARE TO BE RECYCLED.
I AM THE DESIGNER/OWNER IN RESPONSIBLE CHARGE OF THIS TENANT IMPROVEMENT PROJECT. I HAVE INSPECTED THE SITE/PREMISES AND DETERMINED THAT EXISTING CONDITIONS ARE IN FULL
COMPLIANCE WITH CURRENT SITE ACCESSIBILITY REQUIREMENTS TO THE EXTENT REQUIRED BY LAW.
IF THE BUILDING INSPECTOR DETERMINES NONCOMPLIANCE WITH ANY ACCESSIBILITY PROVISIONS, HE/SHE SHALL REQUIRE COMPLETE, DETAILED PLANS CLEARLY SHOWING ALL EXISTING NON
COMPLYING CONDITIONS AND THE PROPOSED MODIFICATIONS TO MEET CURRENT ACCESSIBILITY PROVISIONS AFFECTED BY THE REMODEL (INCLUDING SITE PLAN, FLOOR PLANS, DETAILS,
ETC.). THE PLANS MUST BE STAMPED BY THE FIELD INSPECTOR AND RESUBMITTED TO THE BUILDING DEPARTMENT.
07-31-2025
ACCESSIBLE ENTRANCE/EGRESS NOTES
1 PER CBC 11B-405.8 EXCEPTION 4, 'AT DOOR LANDINGS, HANDRAILS ARE NOT REQUIRED ON RAMP
RUNS LESS THAN 6 INCHES IN RISE OR 72" IN LENGTH.'
SIGNATURE:
DATE: .
1/4" = 1'-0"
ENLARGED SITE PLAN
0.1
B
THE
SITE
2222 S. BRISTOL ST.
BRISTOL ST.
PATCH/REPAIR/SLURRY COAT/RESTRIPE
EXIST. LOT
NEW TACTILE EXIT SIGNAGE PER CBC
1011.3 & 11B-703. GRADE LEVEL EXTERIOR
EXIT DOOR SIGNAGE READS "EXIT". PLEASE
SEE DETAIL 10A7.0 FOR SIGNAGE
REQUIREMENTS.
EXISTING ENTRANCE:
NEW INTERNATIONAL SYMBOL OF
ACCESSIBILITY ADJ. TO DOOR
- ENTRY DOOR HAS 10" KICKPLATE
AND LEVER HARDWARE
NEW LANDSCAPING BY OWNER PUBLIC SIDEWALK
N.A.P.
EXIT DISCHARGE PATH &
ACCESSIBLE PATH OF TRAVEL -
48" MIN. CLEAR WIDTH & LESS
THAN 2% SLOPE/CROSS-SLOPE
AND MAX. 1:20 SLOPE IN
DIRECTION OF TRAVEL
9
A7.0
3
A7.0
7
A7.0
11
A7.0
PROPERTY LINE
- TYP.
PROPERTY LINE
- TYP.
NEW TRUNCATED DOMES
SPAN FULL WIDTH OF
LANDING
EXIST. VAN ACCESSIBLE PARKING
SPACE
NEW ACCESSIBLE PATH
OF TRAVEL FROM PUBLIC
RIGHT-OF-WAY
B
A0.1
3
A3.3
1
A3.3
2
A3.3
NEW SUITE A
SUITE BEXIST.
SUITE A
SUITE C
A PLANCHECK
REVISIONS 10-15-25
TO BE
ELIMINATED
N
REPLACE EXIST.
ACCESSIBLE PARKING
SIGN - WALL MOUNTED
CITY NOTES
1.NO KNOWN EASEMENTS ON SITE.
2.THE ACCESSIBLE ROUTE TO THE PUBLIC RIGHT OF WAY SHALL COMPLY WITH THE FOLLOWING:
A. CBC 11B-302.1 FLOOR SURFACES
B. CBC 11B-303 CHANGES IN LEVEL
C. CBC 11B-307.2 PROTRUDING OBJECTS
D. CBC 11B-307.4 VERTICAL CLEARANCE
E. CBC 11B-403.3 SLOPES
F. CBC 11B-403.5.1 WALKWAY WIDTH
6
A7.0
6
A7.0
PROVIDED:
STANDARD 21
VAN ACCESSIBLE:1
TOTAL 22 (UNCHANGED)
PARKING INFORMATION
NEW 6" CURBED
WALKWAY
FLUSH
INFILL EXIST. RAMP
AND LANDING TO
MATCH EXIST. 6"
CURB HT.
INFILL EXIST. RAMP
AND LANDING TO
MATCH EXIST. 6"
CURB HT.
NEW CONCRETE CURB RAMP
PER CBC 1012 - MAX 5% SLOPE
AND MAX 2% CROSS SLOPE
NEW CONCRETE CURB
RAMPS PER CBC 1012 -
MAX 5% SLOPE AND
MAX 2% CROSS SLOPE
FLUSH
B PLANCHECK
REVISIONS 12-10-25
EXIT DISCHARGE PATH &
ACCESSIBLE PATH OF TRAVEL - 48"
MIN. CLEAR WIDTH & LESS THAN 2%
SLOPE/CROSS-SLOPE AND MAX.
1:20 SLOPE IN DIRECTION OF
TRAVEL
E
SPRNKLR.
101
RECEPTION
100
WAITING
107
OFFICE
109
OP
CHECK-IN
CHECK-OUT
111
WORK AREA 113
PVT.OP
116
OP
117
OP
114
OP
115
OP
110
PVT.OP
106
STORAGE
103
ALL GENDER
RESTROOM
119
STERILIZATION/
LAB
120
OFFICE
104
CONSULTATION
105
CONSULTATION
121
MECHANICAL
SOILED
STERILE
WH
MOP
122
PANO
118
OP
102
ALL GENDER
RESTROOM
FRIDGE
W/D
108
HALLWAY
112
HALLWAY
TYP.
6 TYP.
28 TYP.
31
1652434TYP.TYP.3 TYP.
3 TYP.7 TYP.
62810
30
27TYP.
27 TYP.27 TYP.6 TYP.11 15
7 29
17 TYP.
4 TYP.21
4 TYP.
7 TYP.
7 TYP.
9
21
21
19
26
18
18 23
23
20 TYP.20 TYP.20 TYP.
20 TYP.
13
14
02
06
07
05
08
09
18
171615
14
13
12
1011
E
E
03 04
E
01
TV TV TV TV TV
TV
TV
19 TYP.19 TYP.
8 TYP.
8
E
ELECTRICAL
32
33 TYP.
25 22
19
14
12
10
20
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
SHEET NO.
2509
REVISIONS:
5/30/2025DATE:
PROJECT NO.
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
S
a
n
t
a
A
n
a
,
C
A
9
2
7
0
4
N
FLOOR PLAN
A-1.0
1/4" = 1'-0"
FLOOR PLAN
1.0
A
GENERAL CONSTRUCTION NOTES:
1. DO NOT SCALE FROM PLANS. FIELD VERIFY ALL DIMENSIONS (ESPECIALLY EXISTING STRUCT POSTS) & REPORT ANY DISCREPANCIES TO
ARCHITECT AT ONCE.
2. ALL DIMENSIONS ARE TO CENTERLINE OF STUD OF WALLS UNLESS NOTED OTHERWISE. END DIMENSIONS ARE TO FINISHED INTERIOR FACE
OF EXISTING PERIMETER WALLS.
3. INSTALL DOUBLE STUDS AT JAMBS FOR ALL INTERIOR DOORS.
4. PROVIDE WATER RESISTANT GYPSUM BOARD AT WALLS W/ PLUMBING FIXTURES.
5. PROVIDE 5/8" GMMU (CEMENT BOARD) OVER 2-LAYER #15 FELT AT ALL WALLS SCHEDULED FOR TILED FINISH
6. REFER TO ENGINEER'S DRAWINGS FOR COORDINATION WITH MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS AS REQUIRED.
7. G.C. TO PROVIDE CONDUIT. OWNER TO SUPPLY AND INSTALL ALL TELEPHONE AND DATA JACKS AND WIRING.
GENERAL NOTES
WALL LEGEND
NEW FULL HT. INT. WALL TO MIN. 4" ABOVE SUSP. CLG: 5 8" TYPE 'X' GYP. BD. EA. SIDE 3 5 8"x20 GA. METAL STUDS @ 16" O.C.
W/ SOUND INSULATION BATTS FULL HT. (BRACE TOP OF WALL TO STRUCTURE AT MIN. 48" O.C.)
INTERIOR FINISH NOTES
1. READ WITH FINISH SCHEDULE & SPECIFICATIONS. INTERIOR FINISHES SHALL COMPLY WITH CBC CHAPTER 8 AND TABLE 803.5.
2. PROVIDE CABINETRY SHOP DRAWINGS; TO BE REVIEWED BY ARCHITECT BEFORE STARTING WORK. ALL CABINETS WILL BE EUROPEAN BOX
STYLE, BLUM HINGES, FULL EXTENSION GUIDES, PLASTIC LAMINATE. ALL INTERIORS TO BE KORTRON LINED. INSTALL DOORS, 6" SQ. PULLS
(BRUSHED ALUM.) AND LATCHES AS REQUIRED.
3. VERIFY MATERIALS AND COLORS FOR ALL CABINET FINISHES. INSTALL SOLID SURFACING AND PLASTIC LAMINATE COUNTERTOP
MATERIALS AS NOTED ON COLOR / FINISH SCHEDULE. PROVIDE SAMPLES FOR REVIEW PRIOR TO FABRICATION.
4. PAINT ALL NEW AND EXISTING GYSPUM BOARD WALLS AND CEILINGS. PAINT ALL UNFINISHED SURFACES .
5. INSTALL FLOORING (AND BASE) IN AREAS / ROOMS AS NOTED ON FINISH SCHEDULE. INSTALL GLUE-DOWN CARPET PER FINISH SCHEDULE.
CARPET AND INSTALLATION SHALL COMPLY W/ CBC SECTION 11B-302.2.
6. INSTALL NEW FLOORING & BASE IN ROOMS AS NOTED - SEE FINISH SCHEDULE
7. PROVIDE TRANSITION STRIPS BETWEEN FLOORING OF DIFFERENT TYPES & AT ENTRY DOORS.
8. PROVIDE SQUARE CORNER BEAD AT ALL NEW VERT. GYP. BD. WALL CORNERS AND SQUARE CORNER BEAD AT ALL NEW HORIZONTAL
GYP. BD. CORNERS.
9. PROVIDE NEW BLINDS AT ALL EXTERIOR WINDOWS - SEE SPECS
10. PROVIDE SMOOTH PAINT FINISH FOR ALL DRYWALL.
GENERAL NOTESFLOOR PLAN KEYNOTES ( SEE ALSO ACCESSIBILITY DETAILS ON A7.0)
1 COORDINATE POWER AND DATA WITH INSTALLATION OF OWNER'S DENTAL X-RAY EQUIPMENT (VERIFY MOUNTING HT.
W/ SUPPLIER) - PROVIDE 4X4 WD. POSTS FOR EQUIPMENT MOUNTING SUPPORTS AT WALL / IN CABINET.
2 COORDINATE LOCATION OF ACTIVATION SWITCHES REMOTE FROM OPERATORIES (PROVIDE 3/4" CONDUIT TO 42" HT.
AS REQUIRED). X-RAY ACTIVATION SWITCH BY OWNER.
3 CUSTOM OPERATORY CABINETS - SEE SHEET A3.0. COORDINATE WITH CONDUIT FOR CAT-6 AND ELECTRICAL.
4 COORD. INSTALLATION OF EXAM CHAIRS IN OPERATORIES (SUPPLIED BY OWNER). INSTALL ELEC. AND DATA UNDER
FLOOR SLAB TO UTILITY BOX AT FOOT EA. CHAIR. PROVIDE 2" DIA. MTL. CONDUIT ELECTRICAL, DATA, WATER,
COMPRESSED AIR AND VACUUM LINES TO BE RUN TO CHAIR FOR CHAIR DELIVERY.
5 PROVIDE CONNECTIONS AND COORDINATE INSTALLATION OF OWNER'S STACKED DENTAL VACUUM & AIR
COMPRESSOR. DRAIN TO FLOOR SINK.
6 ACCESSIBLE SINK AND COUNTER - SEE PLUMBING SCHEDULE AND SINK DETAIL
7 WORK SINK - COORD. W/ PLASTER TRAP AT LAB. - SEE PLUMBING SCHEDULE AND CABINET DETAILS
8 PROVIDE COMPRESSED AIR OUTLET AND VACUUM AT 42" AFF
9 NEW ELEC. PANEL-BOARD LOCATION - SEE ELECTRICAL PLANS.
10 LINE OF WALL-MOUNTED CABINET - TYP. COORDINATE INSTALLATION OF WALL CABINETS W/ BACKING IN WALL, INCL.
POWER OUTLETS (AT MICROWAVE SHELF LOCATION, ETC.)
11 NEW DENTAL STERILIZER TOWE PROVIDE POWER/WATER AS NECESSARY - SEE INTERIOR ELEVATIONS
12 PROVIDE 5-TIER MELAMINE-FACED SHELVES AT 15" O.C. VERT. ON KNIFE EDGE BRACKETS AND VERT. MTL. STANDARDS
MAX 24" O.C.
13 ALL EXIST. STRUCT. COLUMNS TO BE PROTECTED IN PLACE. TYP.
14 EXIST. NON FIRE-RATED STRUCTURAL WALLS TO BE PROTECTED IN PLACE - NOTIFY ARCHITECT IMMEDIATELY FOR ANY
ISSUES.
15 ULTRASONIC CLEANER TO BE INSET INTO COUNTERTOP, TYP.
16 VERIFY LOCN. NEW WATER HEATER & DRAIN TO FLOOR SINK - SEE PLUMBING PLANS
17 FRONT RECEPTION COUNTER: TRANSACTION TOP @ 42" HT., ACCESSIBLE TOP @ 31" HT., MIN. 36" WIDE.
18 NEW SEMI-RECESSED FIRE EXTINGUISHER CABINET - INCL. 10-LBS TYPE 2-A-10B:C DRY CHEMICAL FIRE EXTINGUISHER.
VERIFY LOC'N. W/ OWNER / BLDG. INSP. EXTEND GYP. BD. BEHIND UNIT - FIRE EXTINGUISHER TO HAVE A 4" MAXIMUM
PROJECTION [PER 11B-307.2]
19 PROVIDE RECESSED NICHE & 90 DEGREE BOX W/ POWER, DATA, AND CABLE FOR TV LOCATIONS. VERIFY DIMS. W/
OWNER
20 NEW STOREFRONT WINDOW SYSTEM AND DOORS - SEE SCHEDULE
EXISTING INTERIOR/EXTERIOR WALLS & STRUCTURAL WALLS TO REMAIN - PATCH/REPAIR AS NECESSARY- INFORM
ARCHITECTS OF ANY CONFLICTS IN FIELD DURING DEMOLITION
FLOOR PLAN KEYNOTES ( SEE ALSO ACCESSIBILITY DETAILS ON A7.0)
21 NEW ACCESSIBLE ALL GENDER RESTROOMS - PROVIDE WALL MTD. CUSTOM SOLID SURFACE ACCESSIBLE SINK & WALL
MTD. FAUCET W/ ELEC. EYE
22 NEW ELECTRICAL SWITCHGEAR LOCATION - PROVIDE SUPPORT WALL BEHIND FOR MOUNTING - SEE ELECTRICAL
23 WORK SINKS IN TREATMENT ROOMS ARE FOR EMPLOYEE USE ONLY - NO PATIENT USE
24 MECHANICAL CLOSET: PROVIDE 2 LAYER EZ SNAP QUIETROCK W/ GREEN GLUE ACOUSTIC ADHESIVE TO WALLS, GYP.
BD. CLG. & BACK OF DOOR. PROVIDE SOUND SEALS @ DOOR AND DO NOT UNDERCUT DOOR FOR VENTING.
PROVIDE AIR CIRC. FOR ROOM VIA HVAC
25 COORDINATE INSTALLATION OF OWNER'S DRY-VACUUM UNIT. PROVIDE ATTACHMENTS AND ELEC. - INSTALL
VACUUM ON ISOLATION PADS. ENSURE NO VIBRATION/NOISE TRANSFER TO ADJACENT ROOMS.
26 OWNER SUPPLIED SEATING - COLOR, SIZE, STYLE, AND LAYOUT T.B.D.
27 NEW FULL HT. 'FRAMELESS' TEMP. (GLASS ETCHED "TEMPERED") 3
8" GLASS PANEL. WHERE SHOWN ON PLAN ADJOINING:
HERCULITE DOOR W/ CHROME PATCH HARDWARE AND 60" BAR PULLS. SEE ELEVATIONS. INCL. - MITRE CORNER
JOINT - CLR. STRUCT. SILICONE SEALANT.
28 COORDINATE INSTALLATION OF OWNER-SUPPLIED EQUIPMENT - FRIDGE, WASHER/DRYER, ETC.
29 PATIENT CHART CABINET WALL - FULL HT. W/ GYP. BD. SOFFIT STARTING @ 70" A.F.F. - SEE INTERIOR ELEVATION AND
DETAIL.
30 AQUARIUM PLATFORM - SEE ELEVATION AND DETAIL.
31 FLOOR-MOUNTED MOP SINK W/ MOP RACK ABOVE
32 ADJACENT SUITE TO REMAIN (PROFESSIONAL SERVICES - B OCCUPANCY) - WORK LIMITED TO NEW EXTERIOR
STOREFRONT SYSTEM.
33.WHEELCHAIR SPACE PER CBC 11B-802.1
34. MECHANICAL #121 IS AN ANCILLARY SPACE - PER CBC TABLE 509.1 INCIDENTAL USE SPACES REQUIRE A 1 HOUR FIRE
RATING OR AN AUTOMATIC FIRE SPRINKLER SYSTEM. AS THIS BUILDING IS FIRE SPRINLKLERED, 1 HOUR FIRE RATING IS
NOT REQUIRED.
NEW FULL HEIGHT WALL: 5/8" TYPE 'X' GYP. BD. EA. SIDE 3 58"x20 GA. METAL STUDS @ 16" O.C. W/
SOUND INSULATION BATTS FULL HT. (U/S OF EXIST. FLOOR)
NEW LOW WALL AT BASE CABINETRY - 5 8" TYPE 'X' GYP. BD. EA. SIDE 3 5 8"x25 GA. METAL STUDS @ 16" O.C.
3/4" EXT. STUCCO ON GALV. EML ON TYVEK WRAP ON 5/8" CDX PLYWD. ON 2X6 WOOD STUDS AT 16" OC. W/
R-21 BATT INSULATION (5/8" TYPE X GYP. BD. @ INTERIOR)
SIGNAGE - READ W/ SIGN SCHEDULE ON A7.0 & DETAIL 10A7.0.
A EXIT
B EXIT ROUTE
C ALL GENDER ACCESSIBLE RESTROOM
C
C
AA
B
12
A6.1
12
A6.1
5
A6.2
13
A6.1
2A3.0
8A3.0
11A3.0 11A3.0
9A3.0
9A3.0
9A3.0
9A3.0
A3.0
18
16
17
1
A6.0
6
A6.2
9A3.0
13A3.0
14A3.0 8
A6.2
1A
3
.
0
10
A
3
.
0
10
A
3
.
0
9A3.0 9A3.09A3.0
11A3.011A3.0
9A3.0
12A3.0
12A3.0
9A3.0
10
A
3
.
0
A3.0
6
7
4
5
A3.2
3
4
1
22
A3.2
3
4
1
21
3A
3
.
0
10
A
3
.
0
10
A
3
.
0
10
A
3
.
0
10
A
3
.
0
10
A
3
.
0
15
A
3
.
0
9A
3
.
0
1A3.1
PLOT:12/10/25
7
A6.2
3
A6.3
B
A PLANCHECK
REVISIONS 10-15-25
B PLANCHECK
REVISIONS 12-10-25
78'-3"
10'-7"
10
'
-
1
1
"
4'
-
1
1
"
12
'
-
2
1
/
2
"
11
'
-
0
1
/
2
"
9'-10"
9'-5"9'-2 1/2"
13
'
-
1
"
5'-1"7'-10"7'-10"22'-4 1/2"
9'-5"12'-9 1/2"
7'
-
3
"
7'
-
3
"
10
'
-
1
1
"
7'-8 1/2"9'-2 1/2"9'-5"
4'
-
6
"
4'
-
7
"
9'
-
3
"
8'
-
5
1
/
2
"
WH
MOP
7"
4'-5 1/2"5'-0"5'-2 1/2"7'-8 1/2"8'-4 1/2"13'-9"10'-0"2'-0"6'-7"
FRIDGE
W/D
1'-6"
3'-0"
TYP.
3'-6 1/2"
1'-10"
7'-8"3'-6 1/2"4'-1"
3'-0"
3'-0"3'-0"
3'-6 1/2"7'-8"3'-6 1/2"
2'-0 1/2"
3'-0"
TYP.3'-0"
3'-0"3'-0"
5'-1"5'-1"5'-1"5'-1"
1'-0"
13'-6 1/2"6'-5"
1'
-
6
"
1'
-
2
"
3'-0"
3'-0"
10'-7"
3'-0"
5'-8"
10
'
-
0
"
1'
-
0
"
18"
MIN.
4'
-
1
0
1
/
2
"
TV TV TV TV TV
TV
TV
48
"
MI
N
.
60"
MIN.
18"
MIN.
17"-
18"
48
"
MI
N
.
60"
MIN.
12"
MAX
.
12"MAX
.
18"
MIN.17"-
18"
3'-0"
4'
-
0
"
4'-0"
3'
-
0
"
2'-0"2'-0"
9'-1"
1'-0"
4'-2"
3'-0"
3'-0"3'-6"
2'-6 1/2"
3'-0"
3'-6 1/2"2'-11"
3'
-
7
"
2'-8 1/2"
1'-3"
1'
-
1
1
1
/
2
"
1'
-
1
1
1
/
2
"
11
'
-
1
1
/
2
"
5'
-
4
1
/
2
"
6"
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
SHEET NO.
2509
REVISIONS:
5/30/2025DATE:
PROJECT NO.
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
S
a
n
t
a
A
n
a
,
C
A
9
2
7
0
4
DIMENSIONED
FLOOR PLAN
A-1.1
GENERAL CONSTRUCTION NOTES:
1. DO NOT SCALE FROM PLANS. FIELD VERIFY ALL DIMENSIONS (ESPECIALLY EXISTING STRUCT POSTS) & REPORT ANY DISCREPANCIES TO
ARCHITECT AT ONCE.
2. ALL DIMENSIONS ARE TO CENTERLINE OF STUD OF WALLS UNLESS NOTED OTHERWISE. END DIMENSIONS ARE TO FINISHED INTERIOR FACE
OF EXISTING PERIMETER WALLS.
3. INSTALL DOUBLE STUDS AT JAMBS FOR ALL INTERIOR DOORS.
4. PROVIDE WATER RESISTANT GYPSUM BOARD AT WALLS W/ PLUMBING FIXTURES.
5. PROVIDE 5/8" GMMU (CEMENT BOARD) OVER 2-LAYER #15 FELT AT ALL WALLS SCHEDULED FOR TILED FINISH
6. REFER TO ENGINEER'S DRAWINGS FOR COORDINATION WITH MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS AS REQUIRED.
7. G.C. TO PROVIDE CONDUIT. OWNER TO SUPPLY AND INSTALL ALL TELEPHONE AND DATA JACKS AND WIRING.
GENERAL NOTES
WALL LEGEND
NEW FULL HT. INT. WALL TO MIN. 4" ABOVE SUSP. CLG: 5 8" TYPE 'X' GYP. BD. EA. SIDE 3 5 8"x20 GA. METAL STUDS @ 16" O.C.
W/ SOUND INSULATION BATTS FULL HT. (BRACE TOP OF WALL TO STRUCTURE AT MIN. 48" O.C.)
INTERIOR FINISH NOTES
1. READ WITH FINISH SCHEDULE & SPECIFICATIONS. INTERIOR FINISHES SHALL COMPLY WITH CBC CHAPTER 8 AND TABLE 803.5.
2. PROVIDE CABINETRY SHOP DRAWINGS; TO BE REVIEWED BY ARCHITECT BEFORE STARTING WORK. ALL CABINETS WILL BE EUROPEAN BOX
STYLE, BLUM HINGES, FULL EXTENSION GUIDES, PLASTIC LAMINATE. ALL INTERIORS TO BE KORTRON LINED. INSTALL DOORS, 6" SQ. PULLS
(BRUSHED ALUM.) AND LATCHES AS REQUIRED.
3. VERIFY MATERIALS AND COLORS FOR ALL CABINET FINISHES. INSTALL SOLID SURFACING AND PLASTIC LAMINATE COUNTERTOP
MATERIALS AS NOTED ON COLOR / FINISH SCHEDULE. PROVIDE SAMPLES FOR REVIEW PRIOR TO FABRICATION.
4. PAINT ALL NEW AND EXISTING GYSPUM BOARD WALLS AND CEILINGS. PAINT ALL UNFINISHED SURFACES .
5. INSTALL FLOORING (AND BASE) IN AREAS / ROOMS AS NOTED ON FINISH SCHEDULE. INSTALL GLUE-DOWN CARPET PER FINISH SCHEDULE.
CARPET AND INSTALLATION SHALL COMPLY W/ CBC SECTION 11B-302.2.
6. INSTALL NEW FLOORING & BASE IN ROOMS AS NOTED - SEE FINISH SCHEDULE
7. PROVIDE TRANSITION STRIPS BETWEEN FLOORING OF DIFFERENT TYPES & AT ENTRY DOORS.
8. PROVIDE SQUARE CORNER BEAD AT ALL NEW VERT. GYP. BD. WALL CORNERS AND SQUARE CORNER BEAD AT ALL NEW HORIZONTAL
GYP. BD. CORNERS.
9. PROVIDE NEW BLINDS AT ALL EXTERIOR WINDOWS - SEE SPECS
10. PROVIDE SMOOTH PAINT FINISH FOR ALL DRYWALL.
GENERAL NOTESFLOOR PLAN KEYNOTES ( SEE ALSO ACCESSIBILITY DETAILS ON A7.0)
1 COORDINATE POWER AND DATA WITH INSTALLATION OF OWNER'S DENTAL X-RAY EQUIPMENT (VERIFY MOUNTING HT.
W/ SUPPLIER) - PROVIDE 4X4 WD. POSTS FOR EQUIPMENT MOUNTING SUPPORTS AT WALL / IN CABINET.
2 COORDINATE LOCATION OF ACTIVATION SWITCHES REMOTE FROM OPERATORIES (PROVIDE 3/4" CONDUIT TO 42" HT.
AS REQUIRED). X-RAY ACTIVATION SWITCH BY OWNER.
3 CUSTOM OPERATORY CABINETS - SEE SHEET A3.0. COORDINATE WITH CONDUIT FOR CAT-6 AND ELECTRICAL.
4 COORD. INSTALLATION OF EXAM CHAIRS IN OPERATORIES (SUPPLIED BY OWNER). INSTALL ELEC. AND DATA UNDER
FLOOR SLAB TO UTILITY BOX AT FOOT EA. CHAIR. PROVIDE 2" DIA. MTL. CONDUIT ELECTRICAL, DATA, WATER,
COMPRESSED AIR AND VACUUM LINES TO BE RUN TO CHAIR FOR CHAIR DELIVERY.
5 PROVIDE CONNECTIONS AND COORDINATE INSTALLATION OF OWNER'S STACKED DENTAL VACUUM & AIR
COMPRESSOR. DRAIN TO FLOOR SINK.
6 ACCESSIBLE SINK AND COUNTER - SEE PLUMBING SCHEDULE AND SINK DETAIL
7 WORK SINK - COORD. W/ PLASTER TRAP AT LAB. - SEE PLUMBING SCHEDULE AND CABINET DETAILS
8 PROVIDE COMPRESSED AIR OUTLET AND VACUUM AT 42" AFF
9 NEW ELEC. PANEL-BOARD LOCATION - SEE ELECTRICAL PLANS.
10 LINE OF WALL-MOUNTED CABINET - TYP. COORDINATE INSTALLATION OF WALL CABINETS W/ BACKING IN WALL, INCL.
POWER OUTLETS (AT MICROWAVE SHELF LOCATION, ETC.)
11 NEW DENTAL STERILIZER TOWE PROVIDE POWER/WATER AS NECESSARY - SEE INTERIOR ELEVATIONS
12 PROVIDE 5-TIER MELAMINE-FACED SHELVES AT 15" O.C. VERT. ON KNIFE EDGE BRACKETS AND VERT. MTL. STANDARDS
MAX 24" O.C.
13 ALL EXIST. STRUCT. COLUMNS TO BE PROTECTED IN PLACE. TYP.
14 EXIST. STRUCTURAL WALLS TO BE PROTECTED IN PLACE - NOTIFY ARCHITECT IMMEDIATELY FOR ANY ISSUES.
15 ULTRASONIC CLEANER TO BE INSET INTO COUNTERTOP, TYP.
16 VERIFY LOCN. NEW WATER HEATER & DRAIN TO FLOOR SINK - SEE PLUMBING PLANS
17 FRONT RECEPTION COUNTER: TRANSACTION TOP @ 42" HT., ACCESSIBLE TOP @ 31" HT., MIN. 36" WIDE.
18 NEW SEMI-RECESSED FIRE EXTINGUISHER CABINET - INCL. 10-LBS TYPE 2-A-10B:C DRY CHEMICAL FIRE EXTINGUISHER.
VERIFY LOC'N. W/ OWNER / BLDG. INSP. EXTEND GYP. BD. BEHIND UNIT - FIRE EXTINGUISHER TO HAVE A 4" MAXIMUM
PROJECTION [PER 11B-307.2]
19 PROVIDE RECESSED NICHE & 90 DEGREE BOX W/ POWER, DATA, AND CABLE FOR TV LOCATIONS. VERIFY DIMS. W/
OWNER
20 NEW STOREFRONT WINDOW SYSTEM AND DOORS - SEE SCHEDULE
EXISTING INTERIOR/EXTERIOR WALLS & STRUCTURAL WALLS TO REMAIN - PATCH/REPAIR AS NECESSARY- INFORM
ARCHITECTS OF ANY CONFLICTS IN FIELD DURING DEMOLITION
FLOOR PLAN KEYNOTES ( SEE ALSO ACCESSIBILITY DETAILS ON A7.0)
21 NEW ACCESSIBLE ALL GENDER RESTROOMS - PROVIDE WALL MTD. CUSTOM SOLID SURFACE ACCESSIBLE SINK & WALL
MTD. FAUCET W/ ELEC. EYE
22 NEW ELECTRICAL SWITCHGEAR LOCATION - PROVIDE SUPPORT WALL BEHIND FOR MOUNTING - SEE ELECTRICAL
23 WORK SINKS IN TREATMENT ROOMS ARE FOR EMPLOYEE USE ONLY - NO PATIENT USE
24 MECHANICAL CLOSET: PROVIDE 2 LAYER EZ SNAP QUIETROCK W/ GREEN GLUE ACOUSTIC ADHESIVE TO WALLS, GYP.
BD. CLG. & BACK OF DOOR. PROVIDE SOUND SEALS @ DOOR AND DO NOT UNDERCUT DOOR FOR VENTING.
PROVIDE AIR CIRC. FOR ROOM VIA HVAC
25 COORDINATE INSTALLATION OF OWNER'S DRY-VACUUM UNIT. PROVIDE ATTACHMENTS AND ELEC. - INSTALL
VACUUM ON ISOLATION PADS. ENSURE NO VIBRATION/NOISE TRANSFER TO ADJACENT ROOMS.
26 OWNER SUPPLIED SEATING - COLOR, SIZE, STYLE, AND LAYOUT T.B.D.
27 NEW FULL HT. 'FRAMELESS' TEMP. (GLASS ETCHED "TEMPERED") 3
8" GLASS PANEL. WHERE SHOWN ON PLAN ADJOINING:
HERCULITE DOOR W/ CHROME PATCH HARDWARE AND 60" BAR PULLS. SEE ELEVATIONS. INCL. - MITRE CORNER
JOINT - CLR. STRUCT. SILICONE SEALANT.
28 COORDINATE INSTALLATION OF OWNER-SUPPLIED EQUIPMENT - FRIDGE, WASHER/DRYER, ETC.
29 PATIENT CHART CABINET WALL - FULL HT. W/ GYP. BD. SOFFIT STARTING @ 70" A.F.F. - SEE INTERIOR ELEVATION AND
DETAIL.
30 AQUARIUM PLATFORM - SEE ELEVATION AND DETAIL.
31 FLOOR-MOUNTED MOP SINK W/ MOP RACK ABOVE
32 ADJACENT SUITE TO REMAIN - WORK LIMITED TO NEW EXTERIOR STOREFRONT SYSTEM.
33.WHEELCHAIR SPACE PER CBC 11B-802.1
NEW FULL HEIGHT WALL: 58" TYPE 'X' GYP. BD. EA. SIDE 3 58"x20 GA. METAL STUDS @ 16" O.C. W/
SOUND INSULATION BATTS FULL HT. (U/S OF EXIST. FLOOR)
NEW LOW WALL AT BASE CABINETRY - 5 8" TYPE 'X' GYP. BD. EA. SIDE 3 5 8"x25 GA. METAL STUDS @ 16" O.C.
3/4" EXT. STUCCO ON GALV. EML ON TYVEK WRAP ON 5/8" CDX PLYWD. ON 2X6 WOOD STUDS AT 16" OC. W/
R-21 BATT INSULATION (5/8" TYPE X GYP. BD. @ INTERIOR)
SIGNAGE - READ W/ SIGN SCHEDULE ON A7.0 & DETAIL 10A7.0.
A EXIT
B EXIT ROUTE
C ACCESSIBLE RESTROOM
N
1/4" = 1'-0"
FLOOR PLAN
1.0
A
AA
C
C
B
B
2 3 4 6
8
5 7
9 10
TYP.
14 1713
12
TYP.
12
TYP.
12
TYP.
18
11
TYP.
11
TYP.
15
TYP.
11
'
-
1
1
/
2
"
5'
-
4
1
/
2
"
6"
21
'
-
9
1
/
2
"
19
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
SHEET NO.
2509
REVISIONS:
5/30/2025DATE:
PROJECT NO.
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
S
a
n
t
a
A
n
a
,
C
A
9
2
7
0
4
DEMOLITION
PLAN
A-1.2
WALLS/FIXTURES TO BE DEMOLISHED
EXISTING WALLS/FIXTURES TO REMAIN
DEMOLITION PLAN KEYNOTES
WALL LEGEND
1.CARRY OUT ALL DEMOLITION WORK INDICATED IN ACCORDANCE WITH STATE AND LOCAL CODES. CARRY OUT WORK DURING TIMES
PERMITTED BY AND THE LOCAL AUTHORITIES AND INFORM ADJACENT PROPERTIES OF TIMES SCHEDULED FOR NOISY WORK OR ANY
INTERRUPTION IN UTILITIES OR SERVICES. KEEP NUISANCE TO A MINIMUM.
2.ALL FIXTURES, FURNISHINGS AND FINISHES SHOWN ARE TO BE REMOVED, UNLESS EXPRESSLY NOTED HEREIN.
3.REMOVE ALL DEBRIS FROM SITE AS WORK PROCEEDS AND DISPOSE OF PER CODE AND THE LOCAL CODE REQUIREMENTS. INFORM
ARCHITECT IMMEDIATELY IF ANY HAZARDOUS MATERIALS ARE FOUND TO BE PRESENT.
4.PATCH AND REPAIR ANY DAMAGE THAT OCCURS TO THE EXISTING BUILDING SHELL, OR FINISHES NOT INDICATED TO BE DEMOLISHED.
5.EXISTING INTERIOR PARTITIONS AND EXT. WALL FURRING WITHIN EXISTING BLDG. TO BE REMOVED AS INDICATED. REPORT ANY POSSIBLE
STRUCTURAL WALLS, COLUMNS, ETC. TO ARCHITECT IMMEDIATELY, PRIOR TO REMOVAL.
6.REMOVE EXISTING INTERIOR FIXTURES, FURNISHINGS, LIGHTING, FACE FRAMING AND FINISHES, COMPLETELY.
7.REMOVE ALL EXISTING WALL / FLOOR FINISHES WITHIN BLDG.
8.PATCH AND REPAIR ANY PITS OR HOLES IN FLOOR SLAB AS REQUIRED. TRENCH EXISTING CONC. FLOOR SLAB ONLY WHERE NEEDED TO
ACCOMMODATE NEW UTILITIES (COORD. W/ EXISTING STRUCTURE).
9.EXISTING DOORS AND FRAMES, WALLS, FLOOR FIXTURES, FIXTURES, EQUIPMENT AND CABINETS TO BE REMOVED AS INDICATED.
10.COMPLETELY REMOVE ALL EXISTING LIGHTING, ABANDONED PANELS, CEILINGS AND SOFFITS THROUGHOUT UNLESS NOTED.
11.REMOVE EXISTING TOILET ROOM FIXTURES AND SPECIALTIES. CAP WATER / SEWER AND LEAVE READY FOR CONNECTION OR
RELOCATION OF NEW FIXTURES.
12.EXISTING EXTERIOR WINDOWS AND STOREFRONT ENTRANCES AS INDICATED TO TO BE REMOVED AND PREP. FOR NEW.
13.REMOVE ALL EXISTING INTERIOR AND EXTERIOR SIGNS, INCLUDING WINDOW SIGNS. MONUMENTS TO REMAIN.
14.ALL EXISTING HVAC DUCTWORK IS TO BE REMOVED - DO NOT REMOVE ROOFTOP HVAC EQUIPMENT UNLESS EXPRESSLY NOTED.
15.PROTECT IN PLACE EXIST. BUILDING WALLS-STRUCTURAL COLUMNS/FINISHES NOT SLATED FOR DEMO. PROTECT EXISTING DEMISING
WALLS (REPAIR), STRUCTURAL POSTS AND BEAMS.
16.INFORM ARCHITECT IMMEDIATELY OF ANY UN-RESOLVABLE CONFLICTS.
17.ALL UTILITIES TO BE CAPPED OFF PRIOR TO DEMOLITION.
18.EXIST. ROLL UP DOOR AND FRAME TO BE REMOVED -PREP FOR INFILL IF NEW EXTERIOR WALL
19.DEMO EXIST. STRUCT WALL AS SHOWN - REPORT ANY CONFLICTS IMMEDIATELY
1/4" = 1'-0"
DEMOLITION PLAN
1.2
A
N
TYP.
TYP.
TYP.
TYP.11
2
3
TYP.2 TYP.2
4 4
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
SHEET NO.
2509
REVISIONS:
5/30/2025DATE:
PROJECT NO.
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
S
a
n
t
a
A
n
a
,
C
A
9
2
7
0
4
ROOF PLAN
A-1.3
N
1/4" = 1'-0"
ROOF PLAN
2.0
A
GENERAL CONSTRUCTION NOTES:
1. DO NOT SCALE FROM PLANS. FIELD VERIFY ALL DIMENSIONS (ESPECIALLY EXISTING STRUCT POSTS) & REPORT ANY DISCREPANCIES TO
ARCHITECT AT ONCE.
2. ALL DIMENSIONS ARE TO CENTERLINE OF STUD OF WALLS UNLESS NOTED OTHERWISE. END DIMENSIONS ARE TO FINISHED INTERIOR FACE
OF EXISTING PERIMETER WALLS.
3. INSTALL DOUBLE STUDS AT JAMBS FOR ALL INTERIOR DOORS.
4. PROVIDE WATER RESISTANT GYPSUM BOARD AT WALLS W/ PLUMBING FIXTURES.
5. PROVIDE 5/8" GMMU (CEMENT BOARD) OVER 2-LAYER #15 FELT AT ALL WALLS SCHEDULED FOR TILED FINISH
6. REFER TO ENGINEER'S DRAWINGS FOR COORDINATION WITH MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS AS REQUIRED.
7. G.C. TO PROVIDE CONDUIT. OWNER TO SUPPLY AND INSTALL ALL TELEPHONE AND DATA JACKS AND WIRING.
GENERAL NOTESROOF PLAN KEYNOTES
1 EXISTING MECHANICAL PADS AND EQUIPMENT TO REMAIN-- NO WORK - TYP.
2.REMOVE EXISTING CLAY TILE SHINGLE ROOF AND PROVIDE NEW BLACK STANDING SEAM METAL ROOF - ESR-2048 W/
CLASS A FIRE CLASSIFICATION
3.NEW PARAPET - SEE CAP DETAIL 2A6.3
4. PROVIDE THROUGH-PARAPET DRAIN AT BOTTOM OF NEW PARAPET AT ROOF VALLEY - SEE ELEVATIONS
2
A6.3
4
A6.3
5
A6.3
A PLANCHECK
REVISIONS 10-15-25
B PLANCHECK
REVISIONS 12-10-25
WH
MOP
FRIDGE
W/D
TV TV TV TV TV
TV
TV
MAX. EXIT TRAVEL DISTANCE: 18'-7"
(MAX. ALLOWED TO TWO DISTINCT PATHS OF
TRAVEL)100'-0" CBC TABLE 1006.2.1)
MAX. EXIT TRAVEL DISTANCE: 45'-3"
(MAX. ALLOWED 300'-0" CBC TABLE 1017.2)
(B CONSTRUCTION; SPRINKLERED)
A
B D
C
MAX. EXIT TRAVEL DISTANCE: 49'-11"
(MAX. ALLOWED 300'-0" CBC TABLE 1017.2)
(B CONSTRUCTION; SPRINKLERED)
MAX. EXIT TRAVEL DISTANCE: 11'-3"
(MAX. ALLOWED TO TWO DISTINCT PATHS OF
TRAVEL)100'-0" CBC TABLE 1006.2.1)
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
SHEET NO.
2509
REVISIONS:
5/30/2025DATE:
PROJECT NO.
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
S
a
n
t
a
A
n
a
,
C
A
9
2
7
0
4
EGRESS
FLOOR PLAN
A-1.4
N
1/4" = 1'-0"
EGRESS PLAN
1.4
A
AA
C
C
B
B
EGRESS TRAVEL DISTANCE
ROUTE A-D:102'-5" (MAX. EXIT TRAVEL DISTANCE)
ROUTE C-B:83'-0" (MAX. EXIT TRAVEL DISTANCE)
MAX. EXIT ACCESS TRAVEL DISTANCE (B OCC. FULLY SPRINKLERED - CBC TABLE 1017.2):
300'-0"
1.EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. (CBC 1013.3)
2.ELECTRICALLY POWERED EXIT SIGNS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 924. (CBC 1013.5)
3.EMERGENCY POWER SUPPLY TO ILLUMINATE EXIT SIGNS FOR A DURATION OF NOT LESS THAN 90 MINUTES.
4.IN THE EVENT OF POWER SUPPLY FAILURE, AN EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMATICALLY
ILLUMINATE AISLES, LOBBY, CORRIDOR AND EXTERIOR DOOR LANDING. THE EMERGENCY POWER SYSTEM SHALL
ROVIDE POWER FOR A DURATION OF NOT LESS THAN 90 MINUTE AND SHALL CONSIST OF STORAGE BATTERIES,
UNIT EQUIPMENT OR AN ON-SITE GENERATOR. INITIAL ILLUMINATION AVERAGE OF 1 FOOT-CANDLE AND A
MINIMUMS 0.1 FOOT CANDLE AT FLOOR LVEL. (CBC 1008.3)
5.PERIODIC SPECIAL INSPECTION IS REQUIRED DURING ANCHORAGE OF ELECTRICAL EQUIPMENT FOR EMERGENCY
OR STANDBY POWER SYSTEM. (CBC 1705.13.6)
EGRESS NOTES:
B PLANCHECK
REVISIONS 12-10-25
1'
-
8
"
2'-0"
2'-0"
1'
-
8
"
1'
-
0
"
1'
-
8
"
2'-0"
1'
-
1
0
"
2TYP.
19TYP.
10TYP.
2TYP.
6TYP.3TYP.1TYP.
8TYP.1TYP.10TYP.
11 TYP.
TYP.
3 TYP.
14
2TYP.
3
222
1
2
3
3
3
3
1
1
1
1
2
2
2
2
2
2
2
22
22
2
2
2
2 2 2
2
2 2
2
3
2
9TYP.
4TYP.
9TYP.4TYP.
16TYP.
1TYP.
2TYP.19TYP.10TYP.
3
TYP.
3
TYP.
18 TYP.
5TYP.12TYP.
6TYP.
16TYP.
1517TYP.
17TYP.
16 TYP.
17 TYP.
13TYP.
13TYP.
7
20TYP.19TYP.
17
5
TYP.
12
TYP.
10TYP.
10 TYP.
8
6
2'-0"5'-10 1/2"
2'
-
0
"
2'-4 1/2"
2'
-
0
"
4'
-
7
"
1111
11
6
2121
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
SHEET NO.
2509
REVISIONS:
5/30/2025DATE:
PROJECT NO.
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
S
a
n
t
a
A
n
a
,
C
A
9
2
7
0
4
CEILING PLAN
A-2.0
N
1/4" = 1'-0"
PRELIMINARY FLOOR PLAN
1.0
A
CEILING PLAN KEYNOTES
GENERAL NOTES
1.DO NOT SCALE FROM PLANS. VERIFY ALL DIMENSIONS ON SITE & REPORT ANY DISCREPANCIES TO ARCHITECT AT
ONCE.
2. PAINT ALL NEW GYPSUM BOARD CEILINGS - PROVIDE SMOOTH TEXTURE FINISH.
3.COORDINATE REFLECTED CEILING INSTALLATION WITH MECHANICAL AND ELECTRICAL FIXTURES AND OUTLETS, ETC.
REFER TO ENGINEER'S DRAWINGS FOR MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS AS REQUIRED. - SEE
E-SERIES & M-SERIES DWGS. VERIFY ALL HVAC DIFFUSER LOCATIONS IN FIELD. NOTE ALL DISTRIBUTION DUCTS WILL BE
RUN EXTERNALLY, OVER TOP OF EXISTING ROOF.
7.CAREFULLY COORDINATE INSTALLATION/ LOCATIONS OF DUCTWORK DROPS (SUPPLY AND RETURN REGISTERS) WITH
EXISTING ROOF STRUCTURE. REPORT ANY CONFLICTS TO ARCHITECT IMMEDIATELY.
8.INTERIOR CEILING HEIGHTS VARY - MATCH EXISTING HEIGHTS AND CONFIRM LOCATIONS WHERE ADDITIONAL
HEIGHTS, OR DROPPED BEAMS ARE DISCOVERED.
9.EXIT SIGNS TO BE INTERNALLY ILLUM. AND PROVIDED W/ BATTERY BACK-UP OF MIN. 90 MINS. DURATION IN CASE OF
PRIMARY POWER LOSS.
10.PROVIDE MIN. 1 FOOT-CANDLE ILLUM. IN ALL OCCUPIED AREAS OF THE BUILDING AND EGRESS ROUTES.
ACCESS PANEL:
FOR CEILING ACCESS PANEL SEE 0A7.0
FOR ROOF HATCH SEE 0A7.0
MECHANICAL REGISTERS:
REFER TO MECHANICAL DRAWINGS FOR FIXTURE TYPES
LIGHT FIXTURES ETC. (REFER TO ELECTRICAL DWGS:
ILLUMINATED EXIT SIGNS (W/ 90 MIN. BATTERY BACKUP)
2'X4' RECESSED LED PARABOLIC
2'X4' RECESSED LED INDIRECT W/ PERF. MTL. SHIELD
2'X4' RECESSED LED W/ PLASTIC PRISMATIC LENS
RECESSED LED DOWNLIGHT
LED UNDER-CABINET TASK LIGHT (ALKO OR EQ.)
CEILING SPEAKERS (W/ SEP. VOL. CONTROL)
LED WALL SCONCE / VANITY LIGHT AT 84" AFF
CONCEALED LED ROPE LIGHT - CONTINUOUS
CEILING LEGEND
NOTE:
ELECTRICALLY POWERED, SELF-LUMINOUS AND
PHOTO LUMINESCENT EXIT SIGNS SHALL BE LISTED
AND LABELED IN ACCORDANCE WITH UL 924
AND SHALL BE INSTALLED IN ACCORDANCE
WITH THE MANUFACTURERS INSTRUCTIONS AND
CHAPTER 27. EXIT SIGNS SHALL BE ILLUMINATED
AT ALL TIMES. CBC 1011.4
CEILING ACCESSORIES
(REFER TO ELECTRICAL DRAWINGS)
CABLE TV OUTLETTV
SP
CEILING HEIGHTS
1 9'-0"
2 10'-0"
3 11'-0"1 LED PENDANT LIGHT FIXTURE - BROWNLEE OR EQUIV. CONFIRM OWNER SELECTION PRIOR TO ORDERING - SEE ELEC.
2 2'x4' RECESSED INDIRECT LED LIGHT W/ PERF. MTL. SHIELD - SEE ELEC. FIXTURE SCHED.
3 RECESSED 4" SQUARE LED DOWNLIGHT W/ DECORATIVE TRIM - LITHONIA LDN4SQ OR EQUIV. - SEE ELEC. FIXTURE
SCHED.
4 EXTERIOR GRADE 8" LED DOWNLIGHT W/ DECORATIVE TRIM FLUSH WITH WOOD PANEL CEILING - - SEE ELEC. FIXTURE
SCHED.
5 LED TASK LIGHTING, TYP. @ WALL CABINETS. - SEE ELEC. FIXTURE SCHED.
6 GLASS-BLADE EDGE-ILLUM. EXIT LIGHTS W/ GREEN LETTERING. PROVIDE UNITS W/ 90 MIN. BATTERY BACK-UP. - SEE
ELEC. FIXTURE SCHED.
7 NEW DECORATIVE VANITY LIGHTS - SET ON WALL 80" AFF CENTERED ABOVE LAV. BASIN OR EA. SIDE OF MIRROR @ 60"
HT. & PROVIDE POWER FOR PERIM. LED MIRROR. SEE ELEC
8 6" LED DOWNLIGHT W/ DECORATIVE TRIM - LITHONIA LDN6 OR EQUIV. - SEE ELEC.
9 IPE WOOD 6" WDTH. PLANK TO U/S OF EXIST. SOFFIT
10 GYP. BD. CEILING W/ SMOOTH TEXTURE FINISH: 5/8" TYPE 'X' GYPSUM BOARD ON 2X 20 GA. MTL. JOIST STUDS 16" O.C.
W/ SUPPORT / BLK'G/ BRACING AS REQ. - CEILING HEIGHTS AS NOTED
11 CONNECT TO CENTRAL EXHAUST FAN - MECH. DWGS.- COORD. W/ CABINET
12 LINE OF UPPER WALL CABINET, TYP. - COORD. W/ TASK LIGHTING
13 VERIFY EXISTING WINDOW HEAD HEIGHTS AND COORD. W/ NEW WINDOW BLINDS.
14 VERIFY LOCATIONS OF ALL EXISTING STRUCTURAL SUPPORT BEAMS AND MEMBERS. INFORM ARCHITECT IMMEDIATELY
OF ANY CONFLICTS.
15 ENCASE EXISTING COLUMN W/ 5 8" GYP. BD. WRAP.
16 4000K WHITE LED STRIP LIGHTING IN SOFFITs - SEE DETAIL
17 PERIMETER GYP. BD. DROPPED SOFFIT. - SEE DETAILS
18 2-LAYERS 5/8" QUIETROCK W/ GREEN GLUE ADHESIVE. PROVIDE ADDN'L LAYER FIBERGLASS SOUND INSULATION BATT
ABOVE GYP. BD. THIS ROOM ONLY.
19 SUSPENDED T-BAR CEILING SYSTEM: USG DONN DX/XL W/ 24" x 24" 'ASTRO-CLIMA PLUS' ACOUSTIC LAY-IN TILES W/
REBBET EDGE.
WALL LEGEND
NEW FULL HT. INT. WALL TO MIN. 4" ABOVE SUSP. CLG: 5 8" TYPE 'X' GYP. BD. EA. SIDE 3 5 8"x20 GA. METAL STUDS @ 16" O.C.
W/ SOUND INSULATION BATTS FULL HT. (BRACE TOP OF WALL TO STRUCTURE AT MIN. 48" O.C.)
EXISTING INTERIOR/EXTERIOR WALLS & STRUCTURAL WALLS TO REMAIN - PATCH/REPAIR AS NECESSARY- INFORM
ARCHITECTS OF ANY CONFLICTS IN FIELD DURING DEMOLITION
NEW 1 HOUR RATED FIRE BARRIER: 58" TYPE 'X' GYP. BD. EA. SIDE 3 58"x20 GA. METAL STUDS @ 16" O.C. W/
SOUND INSULATION BATTS FULL HT. (U/S OF EXIST. FLOOR) UL: U465
NEW LOW WALL AT BASE CABINETRY - 5 8" TYPE 'X' GYP. BD. EA. SIDE 3 5 8"x25 GA. METAL STUDS @ 16" O.C.
20 FLUSH TRANSITION BETWEEN QYP BD CEILING & ADJ. SUSPENDED CEILING
21.NEW EXTERIOR GRADE DECORATIVE SCONCE LIGHTS BY OWNER - SET ON WALL 80" AFF - SEE ELECT.
3/4" EXT. STUCCO ON GALV. EML ON TYVEK WRAP ON 5/8" CDX PLYWD. ON 2X6 WOOD STUDS AT 16" OC. W/
R-21 BATT INSULATION (5/8" TYPE X GYP. BD. @ INTERIOR)
6
A6.0
7
A6.0
2
A6.0
10
A6.0
10
A6.0
4
A6.0
4
A6.0
6
A6.0
7
A6.0
1 100 - WAITING 2 100 - WAITING 3 112 - HALLWAY 4 101 - RECEPTION
5 101 - RECEPTION 6 101 - RECEPTION 7 101 - RECEPTION 8 100 - WAITING (FISH TANK BASE)9 TYP. OP
10 TYP. 12 O' CLOCK UNIT 11 TYP. OP CAB 12 TYP. PRIVATE OP. CAB 13 108 - HALLWAY
14 108 - HALLWAY
31
"
2'
-
7
"
1'
-
1
0
"
2'
-
7
"
1'
-
1
0
"
31
"
8'-8"
EQ.EQ.EQ.
2'-2"1'-8 1/2"
2'
-
7
"
5'-7"PLASTIC LAM.
FACED DRAWERS
(TYP.)
BASE PER FIN.
SCHED.
WORK SINK
CURVED PLASTIC
LAM. FACED
CABINET
15 111 - WORK AREA 16 17 18 119 - STERILIZATION/LAB
2'
-
1
0
"
1'
-
8
"
3'
-
6
"
1'
-
1
0
"
1'
-
6
"
2'
-
1
0
"
1'
-
8
"
3'
-
6
"
ACCESSIBLE SINK W/ INSUL
PIPES BELOW
OPEN OPEN
1'-0"1'-5"
ULTRASONIC - INSET
INTO COUNTERTOP
KICK OUT WASTE & BIO
DRAWER W/ 6" DROPS
1'-2"
9'-1"
4'-7"1'-10 1/2"10'-7"
4'-10 1/2"1'-0"4'-8 1/2"
1'
-
0
"
3'
-
6
"
2'
-
7
"
4'-0"5'-3"
8"
2'
-
1
0
"
7'-6"
1'-0"2'-0"4'-7"2'-0"1'-0"
7'-1 1/2"
10'-7"5'-3"4'-0"
3'
-
6
"
3'
-
6
"
2'-0"1'-0"5'-10 1/2"2'-4 1/2"
3'
-
3
"
4'-0"
3'-0"2'-11"
3'
-
6
"
1'
-
0
"
1'-0"2'-0"5'-10 1/2"2'-4 1/2"
9'-3"5'-0"
1'
-
0
"
27
"
KNEE
SPACE 27
"
KNEE
SPACE 27
"
KNEE
SPACE
6'-6"
8" X 12" FASTCAP
SPEEDBRACE WALL
BRACKETS
8" X 12" FASTCAP
SPEEDBRACE WALL
BRACKETS
8" X 12" FASTCAP
SPEEDBRACE WALL
BRACKETS
1'-0"2'-0"4'-7"2'-0"1'-0"
FRIDGE
LOCN.
PROVIDE
POWER/WATER
3'-0"
MICROWAVE NICHE -VERIFY
-COORD. W/ ELEC., BOTTOM
SHELF 16" DP.
2'-5"2'-5"2'-0"2'-8"2'-8"1'-4"2'-0"3'-0"3'-0"1'-6"2'-11"
2'
-
0
"
6'
-
0
"
1'-1"2'-4"1'-2"
2'
-
1
0
"
1'
-
8
"
3'
-
6
"
2'
-
1
0
"
1'
-
8
"
3'
-
6
"
2'-2"
2'-2"3'-0"
1'-5"3'-0"3'-0"3'-0"
1'-4"2'-6"1'-0"3'-0"2'-9"2'-0"1'-6"3'-0"3'-0"2'-10"
1'-8"2'-10"2'-10"1'-8"3'-0"1'-2"
12"
RADIUS
2'
-
1
0
"
1'
-
8
"
3'
-
6
"
2'
-
1
0
"
2'
-
1
0
"
2'
-
7
"
1'
-
1
1
"
3'
-
6
"
8'
-
0
"
4"
9'
-
0
"
5'
-
6
"
WORK SINK -
EMPLOYEE USE ONLY
OPEN SHELF/ NICHE FOR
STERILIZERS W/ PULLOUT
SOLID-SURFACING SHELVES
BELOW EA. - VERIFY EQUIP.
SIZES PRIOR TO FABRICATION
ACCESSIBLE SINK W/ INSUL
PIPES BELOW - PROVIDE
WATER FILTER/PURIFIER W/
SEPARATE DISPENSER
DOORS W/ INTEGRAL CRANKED TOE-KICK AND 180 DEGREE
HINGES FOR ACCESSIBILITY - MIN. 30" CLEAR WIDE APPROACH
2'
-
0
"
2'
-
0
"
2'
-
0
"
1'
-
8
"
1'
-
0
"
1'
-
0
"
4 1/2"
14" PATIENT CHART
DIVIDERS @ 4 12"
O.C.
2'-11 1/2"2'-11 1/2"2'-11 1/2"
TOP ROW -
REGULAR STORAGE
PLASTIC LAM.
FACED CABINETS
FULL HT. PLASTIC
LAM. FACED SOFFIT
PLASTIC LAM. FACED
CABINETS (TYP.)
ADJ. SHELVES (TYP.)
COUNTERTOP PER
FIN. SCHED.
CONT. UNDER CAB. TASK
LIGHTING
BASE PER FIN.
SCHED.
PLASTIC LAM. FACED
CABINETS (TYP.)
ADJ. SHELVES (TYP.)
COUNTERTOP & FULL HT.
BACKSPLASH PER FIN.
SCHED.
CONT. UNDER CAB. TASK
LIGHTING
BASE PER FIN.
SCHED.
PLASTIC LAM. FACED
CABINETS (TYP.)
ADJ. SHELVES (TYP.)
COUNTERTOP & FULL
HT. BACKSPLASH PER
FIN. SCHED.
CONT. UNDER CAB. TASK
LIGHTING
BASE PER FIN.
SCHED.
3'-0"
PLASTIC LAM. FACED
CABINETS (TYP.)
ADJ. SHELVES (TYP.)
COUNTERTOP &
FULL HT.
BACKSPLASH PER
FIN. SCHED.
CONT. UNDER CAB. TASK
LIGHTING
BASE PER FIN.
SCHED.
COUNTERTOP PER
FIN. SCHED.
BASE PER FIN.
SCHED.
PLASTIC LAM. FACED
CABINETS (TYP.)
DOORS W/ INTEGRAL CRANKED TOE-KICK AND 180 DEGREE
HINGES FOR ACCESSIBILITY - MIN. 30" CLEAR WIDE APPROACH
COUNTERTOP PER
FIN. SCHED.
BASE PER FIN.
SCHED.
PLASTIC LAM. FACED
CABINETS (TYP.)
2'
-
1
0
"
QUARTZ-SURFACE TRANSACTION TOP -
OWNER TO VERIFY COLOR
ACCESSIBLE
TRANSACTION
TOP
QUARTZ-SURFACE
TRANSACTION TOP -
OWNER TO VERIFY
COLOR
INDIRECT LED LIGHTING
PLAS. LAM. FACE
QUARTZ FACE QUARTZ FACE QUARTZ FACE QUARTZ FACE
PLAS. LAM. FACE PLAS. LAM. FACE PLAS. LAM. FACE
INDIRECT LED LIGHTING
GYP. BD. SOFFITGYP. BD. SOFFIT
FRAMELESS GLASS
WALL/DOOR - SEE DETAIL
STRUCTURAL COLUMN -
PROTECT IN PLACE COVER
WITH GYP. BD. & PAINT
GYP. BD. SOFFIT
STRUCTURAL COLUMN -
PROTECT IN PLACE COVER
WITH GYP. BD. & PAINT
INDIRECT LED LIGHTING
QUARTZ-SURFACE
TRANSACTION TOP - OWNER
TO VERIFY COLOR
PLASTIC LAM.
BASE
FRAMELESS GLASS
WALL/DOOR - SEE DETAIL
PAINTED GYP.
BD. SOFFIT
STRUCTURAL
COLUMN - PROTECT
IN PLACE COVER
WITH GYP. BD. &
PAINT
8"
2'
-
1
0
"
FULL HT. PLASTIC
LAM. FACED SOFFIT
PLAS. LAM.
FINISH
PLASTIC LAM.
BASE
PLASTIC LAM.
BASE
P-LAM.
FINISH
2'
-
1
0
"
4'-1"7"3'-5"
5 1/2"
4'-5 1/2"
7'
-
0
"
2'
-
4
1
/
2
"
4'
-
3
1
/
2
"
1'-9"
2'
-
1
0
"
1'-9"
7'
-
0
"
WORK SINK
1'-2"
5" Ø TRASH CHUTE
1'-8"
119 - STERILIZATION/LAB119 - STERILIZATION/LAB
12" x 12" REVEAL
12" x 12" REVEAL
3'
-
0
"
1'-6"
TANK AND
OTHER EQUP.
BY OWNER -
PROVIDE
DRAIN,
POWER,
WATER
PLASTIC LAM.
BASE
2'-2"1'-8 1/2"
2'
-
7
"
5'-7"
1'-4"
CURVED
(16" RADIUS)
1'-4"
CURVED
(16" RADIUS)
3" RADIUS
PASS THROUGHPLASTIC
LAM. FACED CABINETS
(TYP.)
ADJ. SHELVES (TYP.)
PLASTIC LAM.
FACED BASE
3" SIDE CHASE (WIRE
ROUTING)
1'-10"
2'
-
7
"
1'
-
8
1
/
2
"
4"
3'
-
0
"
5"
8'
-
0
"
1'-2"
5'
-
5
"
1'-10"
3'-6"1'-1"1'-1"
2'-0"1'-6"
1'-2"1'-2"
DOUBLE GLOVE PULL
HOLES W/ BOX CLIPS @
EA. SIDE
COUNTERTOP PER
FIN. SCHED.
PULL-OUT
KEYBOARD TRAY
W/ DROP-DN.
FRONT
FULL HT. BACKSPLASH
3" THICKNESS FOR
WIRE ROUTING
PLAS. LAM. FACED
CABINETS (TYP.)
OBSC. TEMPERED
GLAZED DOORS W/
ADJ. TEMP. GLASS
SHELVES
MONITOR MOUNT
FULL DEPTH DRAWERS
A-DEC CLOCK/TIMER
FLUSH MOUNTED
-PROVIDE UNDER CAB.
TASK LIGHTING
PLASTIC LAM. BASE
COUNTERTOP PER FIN.
SCHEDULE
PLASTIC LAM.
PUSH-TO-OPEN
CABINETS W/O
PULLS
1'-6"1'-6"1'-6"
OPEN
OPEN
PAINTED GYP.
BD. SOFFIT
PAINTED GYP.
BD. SOFFIT
PAINTED GYP.
BD. SOFFIT
PENCIL DRAWERS
1'-5"
BACK FRONT LEFT RIGHT
2'
-
1
0
"
4'-1"7"3'-5"
5 1/2"
4'-5 1/2"
1'-2"1'-8"
2'
-
7
"
CABINET
ELEVATIONS
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
SHEET NO.
2509
REVISIONS:
5/30/2025DATE:
PROJECT NO.
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
S
a
n
t
a
A
n
a
,
C
A
9
2
7
0
4
A-3.0
3/8" = 1'-0"
CABINET ELEVATIONS
3.0
A
8
A6.2
8
A6.2
2
A6.1
6
A6.2
1
1'-6"3'-0"3'-0"1'-11"
2'-8"2'-8"2'-8"1'-5"
2'
-
1
0
"
1'
-
8
"
3'
-
6
"
WORK SINK -
EMPLOYEE USE ONLY
PLASTIC LAM.
FACED CABINETS
(TYP.)
ADJ. SHELVES
(TYP.)
CONT. UNDER
CAB. TASK
LIGHTING
BASE PER FIN. SCHED.
COUNTERTOP & FULL HT.
BACKSPLASH PER FIN.
SCHED.
119 - STERILIZATION/LAB
CABINET
ELEVATIONS
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
SHEET NO.
2509
REVISIONS:
5/30/2025DATE:
PROJECT NO.
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
S
a
n
t
a
A
n
a
,
C
A
9
2
7
0
4
A-3.1
3/8" = 1'-0"
CABINET ELEVATIONS
3.1
A
1 102 - ALL GENDER RESTROOM
2 103- ALL GENDER RESTROOM
MATERIALPRODUCTTRADENAMEMODELNUMBER 17
"
-
1
9
"
19
"
M
I
N
.
GRAB BAR
42"
7"-9"
12"
24" MIN.
34
"
34
"
27
"
MI
N
.
1.5" COVED BASE
5"
34
"
29
"
20"
60"
MIN.
34
"
27
"
17" -
18"
42" GRAB BAR
36"
12"24"
34
"
27
"
MI
N
.
INSULATED
PIPE
60"
MIN.
34
"
27
"
17" -
18"
42" GRAB BAR
36"
12"24"
INSULATED
PIPE
MATERIALPRODUCTTRADENAMEMODELNUMBER17
"
-
1
9
"
19
"
M
I
N
.
GRAB BAR
42"
7"-9"
12"
24" MIN.
34
"
40
"
1.5" COVED BASE
5"
34
"
29
"
20"
40
"
FULL HT. TILE
FINISH - TBD. BY
OWNER TYP.
12" COVED
BASE
42" GRAB BAR
FLUSH HANDLE ON WIDE
SIDE OF TOILET
RECESSED SEAT COVER
DISP.
NEW RECESSED S/STL.
WASTE/TOWEL DISP. -
BOBRICK B-36903
42" GRAB BAR
FLUSH HANDLE ON WIDE
SIDE OF TOILET
RECESSED SEAT COVER
DISP.
24" X 36" LED BACKLIT
MIRROR
24" X 36" LED BACKLIT
MIRROR
FULL HT. TILE
FINISH - TBD. BY
OWNER TYP.
12" COVED
BASE
60
"
ACCESSIBLE SIGN ON
OUTSIDE OF DOOR
60
"
ACCESSIBLE SIGN ON
OUTSIDE OF DOOR
QUARTZ COUNTER
TOP W/ INTEGRATED
SINK
INSULATED
PIPE
NEW RECESSED S/STL.
WASTE/TOWEL DISP. -
BOBRICK B-36903
QUARTZ COUNTER
TOP W/ INTEGRATED
SINK
INSULATED
PIPE
40
"
40
"
RESTROOM
ELEVATIONS
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
SHEET NO.
2509
REVISIONS:
5/30/2025DATE:
PROJECT NO.
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
S
a
n
t
a
A
n
a
,
C
A
9
2
7
0
4
A-3.2
3/8" = 1'-0"
RESTROOM ELEVATIONS
3.2
A
11
A6.1
11
A6.1
10
A7.0
10
A7.0
12
A6.1
12
A6.1
8
A7.0
4
A7.0
8
A7.0
4
A7.0
20'-8"
5'-2 1/2"5'-1 1/2"5'-1 1/2"5'-2 1/2"
1'
-
5
"
6'
-
8
"
1'
-
5
"
9'
-
6
"
1'
-
5
"
6'
-
8
"
1'
-
5
"
9'
-
6
"
1'
-
5
"
6'
-
8
"
1'
-
5
"
9'
-
6
"
5'-11 1/2"5'-11 1/2"6'-4"6'-6 1/2"
11'-10 1/2"16'-4"16'-4 1/2"3'-3"8'-8"
5'-11"5'-11"5'-5 1/2"5'-4 1/2"5'-5 1/2"5'-6"5'-5"5'-6"
11'-9 1/2"
3'-11 1/2"3'-10 1/2"3'-11 1/2"
1'
-
5
"
6'
-
8
"
1'
-
5
"
9'
-
6
"
2 3
1
6'
-
8
"
EXTERIOR
ELEVATIONS
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
SHEET NO.
2509
REVISIONS:
5/30/2025DATE:
PROJECT NO.
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
S
a
n
t
a
A
n
a
,
C
A
9
2
7
0
4
A-3.3
3/8" = 1'-0"
EXTERIOR ELEVATIONS
3.3
A
REPLACE EXIST. CLAY TILE ROOF W/
NEW BLACK STANDING SEAM MTL/
ROOF.
LINE OF OLD FACADE WALL - INFILL
WITH NEW PARAPET TO CREATE
ONE RIGHT ANGLE - WHITE
STUCCO FIN. TYP.
NEW WHITE SMOOTH SANTA
BARBARA STUCCO FIN. - SMOOTH
SANTA BARBARA FINISH ONLY ON
THIS VOLUME AND NEW PARAPETS
NEW LOGO/SIGNAGE UNDER
SEPARATE PERMIT - PROVIDE
POWER
REPLACE EXIST. CLAY TILE ROOF W/
NEW BLACK STANDING SEAM MTL/
ROOF.
REMOVED EXIST. BRICK VENEER
AND PREP FOR NEW STUCCO FIN -
TYP.
NEW STOREFRONT
WINDOW/DOOR SYSTEM
NEW WHITE SAND STUCCO FIN.NEW WHITE SAND STUCCO FIN.
REPLACE EXIST. CLAY TILE ROOF W/
NEW BLACK STANDING SEAM MTL/
ROOF. - COLOR TBD BY OWNER.
REPLACE EXIST. CLAY TILE ROOF W/
NEW BLACK STANDING SEAM MTL/
ROOF
NEW STOREFRONT WINDOW
SYSTEM NEW STOREFRONT WINDOW
SYSTEM
LINE OF EXIST. ROLL UP DOOR -
REMOVE AND INFILL WALL - SEE
A1.0
1X6 IPE WD. SIDING W/
PENETRATING OIL FIN. -
TYP.
1X6 IPE WD. SIDING W/
PENETRATING OIL FIN. -
TYP.
PROVIDE THROUGH-PARAPET
DRAIN WHERE BOTTOM OF ROOF
VALLEY MEETS PARAPET
NEW PARAPET
NEW WHITE SAND STUCCO FIN.NEW WHITE SAND STUCCO FIN.
12
A6.1
NEW PARAPET CAP TO MATCH
STUCCO COLOR
NEW EXTERIOR GRADE SCNCE
LIGHT 80" AFF - BY OWNER - TYP.
T
7'
-
0
"
FIN. PER SCHED.
1/2" GLASS
ETCHED. TEMP.
HERCULITE
GLASS -
PROVIDE 3M
FROSTED FILM
PROVIDE
HDWR. PER
SCHEDULE
3'-0"
6'
-
2
"
10
"
C SCWD W/ P-LAM. FIN.D 1/2" TEMP. GLZ.
HERCULITE DOOR
6'
-
2
"
10
"
7'
-
0
"
FIN. PER SCHED.
3
8" TEMP.
GLZ. -
GLASS
ETCHED
'TEMPERED'
A SCWD W/ P-LAM. FIN.STOREFRONT DOOR
W/ ANO. FINISH
B
7'
-
0
"
7'
-
0
"
FROSTED FIN.
A-4.0
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
SHEET NO.
2509
REVISIONS:
5/30/2025DATE:
PROJECT NO.
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
S
a
n
t
a
A
n
a
,
C
A
9
2
7
0
4
SCHEDULE /
DOOR DETAILS
D O O R S C H E D U L E - READ WITH DOOR NOTES/DETAIL 2 A7.0
WI
D
T
H
HE
I
G
H
T
TH
I
C
K
N
E
S
S
MA
T
E
R
I
A
L
FI
N
I
S
H
MA
T
E
R
I
A
L
FI
N
I
S
H
DE
T
A
I
L
H
E
A
D
DE
T
A
I
L
J
A
M
B
DE
T
A
I
L
S
I
L
L
HA
R
D
W
A
R
E
S
E
T
OP
E
R
A
T
I
O
N
VI
S
I
O
N
P
N
L
.
/
G
L
A
Z
E
D
HARDWARE SETS
P = PAINTED
(E)= EXISTING
ALUM = ALUMINUM W/ PRE-FINISH
KD = KNOCK-DOWN MTL.
VP = VISION PANEL
ANO = ANODIZED ALUMINUM
HARDWARE TYPES (OR EQUAL):
HINGES:HAGER AB800 4.5X4.5 NRP SEC STUD
I.C. RIM CYLINDER: SCHLAGE 20-057
DEADLOCK: SCHLAGE L9460L
EXIT LOCK: SCHLAGE L9080 L/OST 17A
ENTRANCE LOCK: SCHLAGE L9453P 17A
STOREROOM LOCK: SCHLAGE L9080P 17A
OFFICE LOCK: SCHLAGE ALX50P NEP
PRIVACY LOCK: SCHLAGE ALX40 NEP
LATCHSET: SCHLAGE ALX10 NEP
PULLS: HAGER 12J 10" CtoC / BtoB MT'G.
SURFACE CLOSER: LCN 1460
PERIMETER SEALS: ZERO 188 HEAD AND JAMBS
SWEEP: ZERO 39A
DOME STOP: GLYNN JOHNSON FB13 / 14R / FB17
SILENCERS: GLYNN JOHNSON GJ64
SCWD = SOLID CORE WOOD DOOR
DOOR MATERIALS
INTERIOR WALL AND FINISH NOTES
1. ALL METAL STUDS SHALL BE 16" ON CENTER FULL HEIGHT TO 4" ABOVE EXISTING GYP. BD. CEILING SOFFIT, AND BRACED ABOVE WITH
DIAGONAL STEEL STUDS AT 48" ON CENTER, STAGGARED EACH SIDE. PROVIDE ACOUSTICAL LATEX SEALANT AT ALL EXPOSED AND
CONCEALED JOINTS, PER ASTM C 834.
2. PROVIDE FRAMING COMPONENTS COMPLYING WITH ASTM C754/ASTM C840. ALL METAL COMPONENTS TO HAVE G-40 HOT DIP
GALVANIZED COATING PER ASTM A 525. ALL METAL FASTENERS TO BE CORROSION RESISTANT.
3. PROVIDE 5 8" TYPE 'X' GYPSUM BOARD TO EACH SIDE OF ALL NEW STUD WALLS PER ASTM C 36. PROVIDE WATER RESISTANT GYPSUM
BOARD AT ALL PLUMBING WALLS. ENSURE ALL JOINTS ARE FIRETAPED AND SMOOTH. FINISH WITH A SMOOTH TEXTURE.
4. PROVIDE BULLNOSE CORNER BEAD AT ALL VERTICAL GYP. BD. CORNERS AND SQUARE CORNER BEAD AT ALL HORIZONTAL EDGES.
5. PAINTING AND DRYWALL SUB-CONTRACTORS TO ENSURE ALL FINISHES ARE SMOOTH AND WASHABLE. INTERIOR FINISHES
(INCLUDING CARPET AND VINYL COMPOSITION TILE) TO CONFORM TO CHAPTER 8 OF THE U.B.C. CLASS II; FLAME SPREAD INDEX 200
MAX; SMOKE DENSITY RATING 450 MAX. ALL DECORATIVE MATERIALS SHALL BE MAINTAINED IN A FLAME RETARDANT CONDITION.
6. COORDINATE INSTALLATION OF GLUE-DOWN COMMERCIAL CARPET IN ROOMS INDICATED. ENSURE COMPLIANCE WITH CRI 104,
SECTION 9 "GLUE DOWN". SEE FINISH SCHEDULE.
7. FLOORING CONTRACTOR SHALL PREPARE ALL SUBSTRATES, INCLUDING CEMENTITIOUS FEATHERING/FLOATING, AS REQUIRED,
INCLUDING ALL TRENCH PATCH AREAS, ROUGH & UNEVEN, ETC. SLABS.
8. NEW VINYL TILE FLOORING SHALL BE INSTALLED IN ROOMS NOTED. ALL JOINTS TO BE SEAMED PER MANUFACTURER'S
INSTRUCTIONS. COLOR TO BE CONFIRMED BY ARCHITECT / OWNER PRIOR TO INSTALATION. SEE FINISH SCHEDULE. PROVIDE
APPROVED SEALER TO CONCRETE FLOOR SLAB AREAS WHERE NEW, PATCHED OR EXHIBITING EVIDENCE OF MOISTURE OFF-GASING.
9. REFER TO INTERIOR MATERIALS AND FINISHES LIST BELOW: CONFIRM ALL TILE, PLASTIC LAMINATE, WALL AND FLOORING SELECTIONS
WITH OWNER PRIOR TO ORDERING. ALL FINISHES BY CONTRACTOR, UNLESS SPECIFICALLY NOTED OTHERWISE.
1.112 PR x 4" BUTT HINGES
LEVER CYL. PASSAGE
O/H CLOSER, STOP
2.112 PR x 4" BUTT HINGES
LEVER CYL. LOCK
O/H CLOSER, STOP
PROVIDE KEYPAD ENTRY LOCKET
AT DOORS 1,7,8,9
3.112 PR x 4" BUTT HINGES
LEVER CYL. PRIVACY LOCK
O/H CLOSER, STOP
4.STOREFRONT PIVOT HINGES
PAIR 12" 'D' PULLS
PAIR INTEGRATED CLOSERS
SARGENT 80 SERIES RIM PANIC BAR
DEADLOCKS: ADAMS RITE D.R. MS
1850, MS 4303, OR MS 4002, OR EQ.
WEATHERSTRIPPING, THRESHOLD &
STOPS
5.2"X6" POL. CHROME PATCH HDWR.
60" POL. CHROME BAR PULL, NO
STOP
WWW.SPECIALTYGLASSDOORS.COM
7.R 12" PLAN TEK 'D' PULLS HAFELE
FUTURA TYPE 2 AND STOPS
8.EZY CONCEPT EZY JAMB SRC FRAME
LEVER CYL. PASSAGE 3 - ROCYORK
RYST-120 CONCEALED HINGES
ROCKYORK CONCEALED CLOSER
9.60" POL. CHROME BAR PULL
Description
TEXT / BRAILLE: "EXIT ROUTE"
WALL MOUNTED ADJ. DOOR W/ RAISED
ACCESSIBLE SIGN SCHEDULE
No. /
Loc'n.
01
03
EXIT ROUTE
Text
2
Qty.
READ WITH ACCESSIBILITY NOTES ON SHEET A0.0 & A7.0
Mounting
02
EXIT 4 WALL MOUNTED ADJ. DOOR W/ RAISED
TEXT / BRAILLE: "EXIT"
ALL GENDER ACCESSIBLE TOILET SIGN:
INSET TRIANGLE
DOOR MOUNTED 1/4" THK. SIGN W/ 12" EDGE CIRCLE/
ALL GENDER
RESTROOM 2
SIGNS TO BE 3/8" POLYCARBONATE W/ MECHANICAL ATTACHMENT. SIGNS SHALL COMPLY
WITH CBC 1011.4 &11B-703. PROVIDE CONTRASTING COLORS AND VERIFY SIGN COLORS WITH
OWNER. READ WITH DETAIL 10A7.0.
DOOR NOTES
1. NEW INTERIOR DOORS AT ALL AREAS TO BE 1-3 4" SOLID CORE WOOD DOOR WITH FINISHES PER SCHEDULE, PER
NWWDA QUALITY STANDARD 1.S.1-A. FRAMES AS ABOVE, EXCEPT PROVIDE FRAMES AS WESTERN INTEGRATED 20 GA.
PRE-FINISHED KNOCK-DOWN CONSTRUCTION WITH CLEAR ANNODIZED FINISH.
3. MOUNT HARDWARE UNITS AT HEIGHTS INDICATED IN NWWDA STANDARD 1.S.1XXX HARDWARE LOCATIONS FOR
FLUSH, ETC. WOOD DOORS, EXCEPT AS REQUIRED FOR ACCESSIBILITY UNDER TITLE 24.
4. PROVIDE ALL CYLINDER TYPE LEVER HARDWARE WITH BRUSHED FINISH FOR ALL HARDWARE. HINGES TO BE 4-1/2"
X 4-1/2" HINGE CO.; LOCKS SHALL BE SCHLAGE AL / SPARTA ND SERIES, AS REQUIRED FOR ACCESSIBILITY UNDER
TITLE 24.
5. INSTALL PERKO #254A OR EQUAL ADA/ TITLE-24 APPROVED ALUMINUM TRANSITION STRIPS @ DOORWAYS BETWEEN
FLOORING OF DIFFERENT TYPES, AND AS REQUIRED.
6. PROVIDE DOOR SEALS AS NOTED ON DOOR SCHEDULE *
7. EXIT ACCESS DOORS TO HAVE LEVER HARDWARE, WHICH RETRACTS BOTH LOCKS IN A SINGLE OPERATION. CBC
1008.1.9.5
8. DOOR SIGNS TO BE 1/4" ACRYLIC W/ MECHANICAL ATTACHEMENT. PROVIDE CONTRASTING COLORS AND VERIFY
SIGN COLORS WITH OWNER
9.LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL SHALL BE
OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, BY PANIC BARS, PUSH PULL ACTIVATING BARS, OR
OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING
HARDWARE. CBC 1133B.2.5.2.
10.MAIN EXTERIOR DOORS AND DOORS WITH EXIT HARDWARE SHALL INCLUDE:
A.THE LOCKING DEVICE IS READILY DISTINGUISHABLE AS 'LOCKED'.
B.A READILY VISIBLE DURABLE SIGN IS POSTED ON THE EGRESS SIDE ON OR ADJACENT TO THE DOOR STATING: THIS
DOOR TO REMAIN UNLOCKED WHILE THIS SPACE IS OCCUPIED. THE SIGN SHALL BE IN LETTERS 1 INCH HIGH ON
A CONTRASTING BACKGROUND.
C.THE USE OF THE KEY-OPERATED LOCKING DEVICE IS REVOKABLE BY THE BUILDING OFFICIAL FOR DUE CAUSE.
11. EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS AT LEAST AN
AVERAGE OF 1 FOOT-CANDLE (11 LUX) AND A MINIMUM AT ANY PINT OF 0.1 FOOT-CANDLE (1 LUX) MEASURED ALONG
THE PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITTED TO DECLINE TO 0.6 FOOT-CANDLE (0.6
LUX) AT THE END OF THE EMERGENCY LIGHTING TIME DURATION. A MAXIMUM-TO-MINIMUM ILLUMINATION UNIFORMITY
RATIO OF 40 TO 1 SHALL NOT BE EXCEEDED.
12. DOORS IN A MEANS OF EGRESS SHALL BE MIN. 32" CLEAR. CBC 1008.1.1
13. INTERIOR ACCESSIBLE ROUTES SERVING AN OCCUPANT LOAD OF 10 OR MORE SHALL NOT BE LESS THAN 44" WIDE.
INTERIOR ACCESSIBLE ROUTES SERVING AN OCCUPANT LOAD OF 10 OR LESS SHALL NOT BE LESS THAN 36" WIDE. CBC
11B-403.5.1.
Mounting
ALL FINISHES, MATERIALS, ETC. ARE SUBJECT TO CONFIRMATION AND
SELECTION BY OWNER. CONTRACTOR TO PROVIDE SAMPLES, CUT
SHEETS, COLORS, ETC. TO OWNER PRIOR TO CONSTRUCTION.
F I N I S H S C H E D U L E - READ WITH DOOR NOTES/DETAIL 2 A7.0F I N I S H S C H E D U L E - READ WITH DOOR NOTES/DETAIL 2 A7.0
LOCATION RATING
NO ROOM OPENINGTYPE FRAME HARDWARE REMARKS ROOM NO FLOOR COUNTERWALLSBASE CABS REMARKS
110
112
111
106
103
109
107
104
101
100
RECEPTION
WAITING
105
108
FINISH SCHEDULE - ALL FINISHES SHALL COMPLY WITH CBC TABLE 803.13
READ W/ INTERIOR DESIGN MATERIALS AND COLORS SCHEDULE
PL-1 PLASTIC LAMINATE: WILSONART, COLOR: TBD (CONTACT: JUSTIN CASTILLO 714.493.9960) TBD
PL-2 PLASTIC LAMINATE: WILSONART, COLOR: TBD (CONTACT: JUSTIN CASTILLO 714.493.9960) TBD
PL-3 DOORS ONLY: PLASTIC LAMINATE: WILSONART, COLOR: TBD (CONTACT: JUSTIN CASTILLO 714.493.9960) TBD
FT-1 PORCELAIN FLOOR TILE: PORCELANOSA, COLOR: TBD SIZE: TBD (CONTACT: OLIVIA 714.772.3183)
GROUT: 1
16" CUST. BLDNG. PRODUCT, COLOR: TBD
FT-2 PORCELAIN FLOOR TILE: PORCELANOSA, COLOR: TBD SIZE: TBD (CONTACT: OLIVIA 714.772.3183)
GROUT: 1
16" CUST. BLDNG. PRODUCT, COLOR: TBD
WT-1 PORCELAIN WALL TILE: PORCELANOSA, COLOR: TBD SIZE: TBD (CONTACT: OLIVIA 714.772.3183)
GROUT: 1
16" CUST. BLDNG. PRODUCT, COLOR: TBD
VP-1 VINYL PLANKS: METROFLOR BY ARMSTRONG, COLOR: TBD (CONTACT: JIM KILLEEN 951.264.2661) TBD
QZ-1 QUARTZ SURFACE: RAINBOW STONE W/ PRE FINISHED STRAIGHT EDGE, COLOR: TBD (CONTACT: 858.271,8177) TBD
FRP-1 FIBER REINFORCED BOARD: COLOR: TBD TYP. ALL WALLS JANITOR CLOSET
RS-1 ROLLER SHADES: HUNTER DOUGLAS CONTRACT, SHEER WEAVE 4600, COLOR: TBD (CONTACT: MATT 949-330-9756)
RB-1 TOPSET VINYL BASE: FLEXCO , COLOR: TBD (CONTACT: JIM KILLEEN 951.264.2661) TBD
TB-1 6" COVED TILE BASE: PORCELANOSA, COLOR: TBD SIZE: TBD (CONTACT: OLIVIA 714.772.3183)
P-1 FIELD EGGSHELL/ CEILING FLAT PAINT: DUNN EDWARDS, COLOR: TBD TBD
P-2 ACCENT EGGSHELL PAINT: DUNN EDWARDS, COLOR: TBD TBD
P-3 SCRUBBABLE ENAMEL PAINT: DUNN EDWARDS, COLOR: TBD TBD
102
WORK AREA
STORAGE
HALLWAY
01 108 - HALLWAY NON RATED B 3'-0"8'-0"1-3/4"ALUM/GLZ GLZ ALUM ANO 2A6.1 2A6.1 2A6.1 4 EXIT YES
PRIVATE OP
PRIVATE OP
CONSULTATION
ALL EXIST. DOORS MIN. 36" WIDTH W/ LEVER ACTION HDWR.
02 100 - WAITING NON RATED B 3'-0"8'-0"1-3/4"ALUM/GLZ GLZ ALUM ANO 2A6.1 2A6.1 2A6.1 4 EXIT YES
04 EXISTING ADJACENT SUITE NON RATED B 3'-0"8'-0"1-3/4"ALUM/GLZ GLZ ALUM ANO 2A6.1 2A6.1 2A6.1 4 EXIT YES
05 100 - WAITING NON RATED D 3'-0"8'-0"1/2"GLASS PL -----5 PASSAGE NO
06 103 - ALL GENDER RESTROOM NON RATED A 3'-0"8'-0"1-3/4"SCWD PL KD ANO 6A6.1 6A6.1 6A6.1 3 PRIVACY NO
07 102 - ALL GENDER RESTROOM NON RATED A 3'-0"8'-0"1-3/4"SCWD PL KD ANO 6A6.1 6A6.1 6A6.1 3 PRIVACY NO
08 120 - OFFICE NON RATED D 3'-0"8'-0"1/2"GLASS GLZ --14A6.1 14A6.1 14A6.1 9 SLIDING YES
09 121 - MECHANICAL 1 HR. FIRE RATED A 3'-0"8'-0"1-3/4"SCWD P --4A6.1 4A6.1 4A6.1 8 PASSAGE NO
11 111 - WORK AREA NON RATED C 3'-0"8'-0"1-3/4"SCWD PL KD ANO 6A6.1 6A6.1 6A6.1 1 PASSAGE YES
ALL NEW GLASS DOORS,
STOREFRONTS, PANELS, ETC.
SHALL BE SAFETY GLAZED AND
GLASS ETCHED 'TEMPERED'
12 110 - PRIVATE OP NON RATED C 3'-0"8'-0"1-3/4"SCWD PL KD ANO 3A6.1 3A6.1 3A6.1 7 POCKET YES
NEW STOREFRONT ENTRY/EXIT DOOR
MOUNTED ON WALL - SEE
ACCESS SIGNAGE DETAIL
10A7.0.
MOUNTED ON WALL - SEE
ACCESS SIGNAGE DETAIL
10A7.0.
MOUNTED ON DOOR - SEE
ACCESS SIGNAGE DETAIL
10A7.0.
10 113 - PRIVATE OP NON RATED C 3'-0"8'-0"1-3/4"SCWD PL KD ANO 3A6.1 3A6.1 3A6.1 7 POCKET YES
DOOR 6, 7
DOOR 05, 19
DOOR 01,02,
03, 04
113PRIVATE OP
114OP
115OP
116OP
117OP
118OP
119STERILIZATION/LAB
120OFFICE
121MECHANICAL
CONSULTATION
OFFICE
HALLWAY
122PANO
14 107 - OFFICE NON RATED A 3'-0"8'-0"1-3/4"SCWD PL KD ANO 6A6.1 6A6.1 6A6.1 2 LOCK NO
DOOR TYPE
03 EXISTING ADJACENT SUITE NON RATED B 3'-0"8'-0"1-3/4"ALUM/GLZ GLZ ALUM ANO 2A6.1 2A6.1 2A6.1 4 EXIT YES
HERCULITE DOOR W/ POL. CHROME PATCH HARDWARE. PROVIDE FROSTED/PRIVACY FILM TO DOOR,
PER OWNER DIRECTION.
CRL 690 SERIES BRUSHED STAINLESS ANODIZED DROP CEILING SLIDING DOOR
NEW STOREFRONT ENTRY/EXIT DOOR - ADD SIGN "THIS DOORTO
REMAIN UNLOCKED WHILE THIS SPACE IS OCCUPIED"
COORDINATE COLOR/MATERIAL SELECTIONS W/ OWNER, TYP. ALL ROOMS
P-1/P-2FT-1 RB-1 PL-1QZ-1 @42" HT.
PL-2 @31" HT.
P-1/P-2RB-1 PL-1
PROVIDE WAINSCOT TO 48" HT. ALL WALLS
RB-1
RB-1 --P-1/P-2
RB-1 SS-1 PL-1P-1/P-2
VP-1 RB-1 PL-1P-1/P-2
VP-1 RB-1 PL-1P-1/P-2
VP-1 RB-1 PL-1P-1/P-2
RB-1 P-1/P-2
RB-1
VP-1 RB-1 --
RB-1
RB-1
RB-1
VP-1 RB-1 P-1/P-2
RB-1 PL-1P-1/P-2
RB-1 P-1/P-2VP-1
RB-1 PL-1P-1/P-2
RB-1 --
EXIT SIGNAGE AND EGRESS ILLUMINATION NOTES
1. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED.
2. EXIT SIGNS ILLUMINATED BY AN EXTERNAL SOURCE SHALL HAVE AN INTENSITY OF NOT LESS THAN 5 FOOT CANDLES (54
IUX)
3. INTERNALLY ILLUMINATED SIGNS SHALL BE LISTED AND LABELED AND SHALL BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER’S INSTRUCTIONS AND CBC SECTION 2702.
4. EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. (CBC SECTION 1013.3)
5. EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL
KNOWLEDGE OR EFFORT. SEE CBC SECTION 1010.1.9.3 FOR EXCEPTIONS
6. DOOR HANDLES, LOCK AND OTHER OPERATING DEVICES SHALL BE INSTALLED AT A MIN. 34” AND A MAX. 48” ABOVE
THE FINISHED FLOOR
7. ALL EGRESS DOOR OPERATION SHALL ALSO COMPLY WITH SECTION 1010.1.9 - 1010.1.9.12.
8. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BE ILLUMINATED AT ALL TIMES THE BUILDING SPACE
SERVED BY THE MEANS OF EGRESS IS OCCUPIED.
9. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT-CANDLE AT THE WALKING SURFACE.
10. THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL NORMALLY BE PROVIDED BY THE PREMISES'
ELECTRICAL SUPPLY. IN THE EVENT OF POWER SUPPLY FAILURE, AN EMERGENCY ELECTRICAL SYSTEM SHALL
AUTOMATICALLY ILLUMINATE THE FOLLOWING AREAS:
I. AISLES AND UNENCLOSED EGRESS STAIRWAYS IN ROOMS AND SPACES THAT REQUIRE TWO OR MORE MEANS OF
EGRESS.
II. CORRIDORS, EXIT ENCLOSURES AND EXIT PASSAGEWAYS IN BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS.
III. EXTERIOR EGRESS COMPONENTS AT OTHER THAN THE LEVEL OF EXIT DISCHARGE UNTIL EXIT DISCHARGE IS
ACCOMPLISHED FOR BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS.
IV. INTERIOR EXIT DISCHARGE ELEMENTS, AS PERMITTED IN CBC SECTION 1028.1, IN BUILDINGS REQUIRED TO
HAVE TWO OR MORE EXITS.
V. EXTERIOR LANDINGS, AS REQUIRED BY CBC SECTION 1010.1.6, FOR EXIT DISCHARGE DOORWAYS IN BUILDINGS
REQUIRED TO HAVE TWO OR MORE EXITS.
11.THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES AND SHALL
CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT OF AN ON-SITE GENERATOR. THE INSTALLATION OF THE EMERGENCY
POWER SYSTEM SHALL BE IN ACCORDANE WITH CBC SECTION 2702.
HERCULITE DOOR W/ POL. CHROME PATCH HARDWARE. PROVIDE FROSTED/PRIVACY FILM TO DOOR,
PER OWNER DIRECTION.
13 109 - PRIVATE OP NON RATED C 3'-0"8'-0"1-3/4"SCWD PL KD ANO 3A6.1 3A6.1 3A6.1 7 POCKET YES
15 106 - STORAGE NON RATED A 3'-0"8'-0"1-3/4"SCWD PL KD ANO 6A6.1 6A6.1 6A6.1 2 LOCK NO
16 105 - CONSULTATION NON RATED D 3'-0"8'-0"1/2"GLASS GLZ -----5 PASSAGE YES
17 104 - CONSULTATION NON RATED D 3'-0"8'-0"1/2"GLASS GLZ -----5 PASSAGE YES
18 108 - HALLWAY NON RATED C 3'-0"8'-0"1-3/4"SCWD PL KD ANO 6A6.1 6A6.1 6A6.1 1 PASSAGE YES
HERCULITE DOOR W/ POL. CHROME PATCH HARDWARE. PROVIDE FROSTED/PRIVACY FILM TO DOOR,
PER OWNER DIRECTION.
EZY CONCEPT EZY JAMB SRC FRAME LEVER CYL. PASSAGE 3 - ROCYORK RYST-120 CONCEALED
HINGES ROCKYORK CONCEALED CLOSER - PROVIDE SOUND SEALS @ PERIM. OF DOOR
NEW STOREFRONT ENTRY/EXIT DOOR
NEW STOREFRONT ENTRY/EXIT DOOR
ALL GENDER
RESTROOM
ALL GENDER
RESTROOM
QZ-1 @42" HT.
PL-2 @31" HT.
QZ-1 -WT-1FT-2 TB-1
QZ-1 -WT-1FT-2 TB-1
RB-1 --P-1/P-2
RB-1
--P-1/P-2
--P-1/P-2
SS-1 PL-1
PL-1
PL-1P-1/P-2
PL-1P-1/P-2
PL-1P-1/P-2
PL-1P-1/P-2
P-1/P-2
P-1/P-2
SS-1
SS-1
SS-1
SS-1
SS-1
SS-1
SS-1
SS-1
SS-1
SS-1
POCKET DOOR W/ 32" CLR. OPENING
POCKET DOOR W/ 32" CLR. OPENING
POCKET DOOR W/ 32" CLR. OPENING
FT-1
VP-1
VP-1
VP-1
VP-1
FT-1
FT-1
FT-1
FT-1
FT-1
FT-1
FT-1
FT-1
FT-1
E EXISTING HALLOW METAL ---------------ALL EXSISTING HALLOW METAL DOORS TO REMAIN - SAND, PAINT, AND CHANGE HARDWARE - TYP.
--
DIVISION 1
GENERAL REQUIREMENTS
1. ALL WORK SHALL BE WARRANTED FOR 1 YEAR AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP.
2. ALL WORK PERFORMED SHALL BE COMPLETED IN ACCORDANCE WITH ALL STATE, FEDERAL, AND LOCAL CODES, ORDINANCES, AND
LAWS, INCLUDING THE 2022 BUILDING STANDARDS ADMINISTRATIVE CODE, PART 1, TITLE 24 C.C.R.: 2022 CALIFORNIA BUILDING CODE
(CBC), PART 2, TITLE 24 C.C.R.: 2022 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, TITLE 24 C.C.R: 2022 CALIFORNIA MECHANICAL
CODE (CMC), PART 4, TITLE 24 C.C.R: AND 2022 CALIFORNIA PLUMBING CODE (CPC), PART 5, TITLE 24 C.C.R
3. CONTRACTORS SHALL COORDINATE THEIR WORK WITH UTILITIES COMPANIES AND OTHER TRADES. ANY CONFLICTS SHALL BE
BROUGHT TO THE ARCHITECT'S ATTENTION PRIOR TO THE WORK BEING INSTALLED. FAILURE TO DO SO WILL MAKE THE CONTRACTOR
RESPONSIBLE FOR THE COST TO CORRECT THE WORK.
4. EACH CONTRACTOR SHOULD VISIT THE SITE OF THE PROPOSED WORK, VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS,
INCLUDING EASEMENTS, NOTIFY THE ARCHITECT OF ANY DISCREPANCIES, AND FULLY ACQUAINT THEMSELF WITH THE SITE CONDITIONS
RELATING TO CONSTRUCTION.
5. EACH CONTRACTOR WILL BE REQUIRED TO PROVIDE CERTIFICATES OF INSURANCE ISSUED BY AN ACCEPTABLE COMPANY PRIOR TO
COMMENCEMENT OF WORK ON THE SITE.
6. MAINTAIN AREAS FREE OF WASTE MATERIALS, DEBRIS, AND RUBBISH. MAINTAIN SITE IN A CLEAN AND ORDERLY CONDITION. THE
CONTRACTOR SHALL DISPOSE OF ALL DEMOLITION AND CONSTRUCTION DEBRIS OFF SITE AND IN AN APPROVED MANNER,
ACCORDING TO STATE AND CITY CODES. NOTIFY ARCHITECT AT ONCE IF ANY HAZARDOUS MATERIALS ARE ENCOUNTERED.
7. COMPLETE FINAL CLEANING PRIOR TO WALK-THROUGH AND PREPARATION OF PUNCH LIST. CLEAN ALL SURFACES EXPOSED TO VIEW.
REMOVE WASTE AND SURPLUS MATERIALS, RUBBISH, AND CONSTRUCTION FACILITIES FROM SITE.
8. ALL EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. NO
DEADBOLTS, SLIDING BOLTS, ETC. PROVIDE SELF RELEASING LOCKING DEVICES ON EXIT DOORS.
9. ALL PRIMARY ENTRANCES AND ALL FACILITIES IN THE BUILDING SHALL BE MADE ACCESSIBLE TO THE HANDICAPPED PER CBC CHAPTER
11B.
10. CONTRACTOR TO SECURE PERMIT AS REQUIRED BY THE CITY FIRE MARSHALL, PRIOR TO OCCUPYING THIS SPACE.
11. POST OCCUPANT LOAD SIGNS COMPLYING WITH CFC 1003 AND CBC 1004.3 AS REQUIRED.
12. FINISH CONTRACTORS SHALL ENSURE ALL FINISH MATERIALS WILL BE FLUSH AND WASHABLE. INTERIOR FINISH MUST CONFORM TO THE
REQUIREMENTS OF CBC.
13. FIRE EXTINGUISHERS TO BE PROVIDED, PER CFC 906 & TABLE 906.3(1). TO BE TYPE 2A10BC WITH CURRENT FIRE MARSHALL SERVICE
TAG, MOUNTED IN VISIBLE LOCATION, NOT MORE THAN 75 FT. FROM ANY POINT IN THE SPACE, AS INDICATED ON DWG.S. PROVIDE
SEMI RECESSED CABINET INSTALLATION: J.L. INDUSTRIES STOCK CABINET
W/ FIRE EXTINGUISHER - ABC #5.
14. ALL ELECTRICAL INSTALLATIONS, MAINS SERVICE AND PANEL BOARDS SHALL BE PER U.E.C.17. PROVIDE FIRE DAMPERS IN ALL DUCTS
PENETRATING FIRE RATED WALLS AND CEILINGS. SEE MECHANICAL SERIES DRAWINGS.
15. WHERE NO CONSTRUCTION DETAILS ARE SHOWN OR NOTED FOR ANY PART OF THE WORK TO BE DONE, DETAILS SHOULD BE SAME
AS FOR OTHER SIMILAR WORK.
16. APPROVED HARDWIRED SMOKE DETECTORS ARE TO BE INSTALLED IN ALL OFFICES, STORAGE ROOMS AND HALLWAYS, PER CODE.
17. SITE SECURITY: PROJECT SITE SHALL BE SECURED AND MONITORED AT ALL TIMES. PROVIDE. TEMPORARY PORTABLE CHAIN-LINK
FENCING AS REQUIRED; MINIMUM 6 FEET HIGH.
18. PROVIDE AND PAY FOR ALL TEMPORARY UTILITIES, INCLUDING POWER, TELEPHONE, WATER AND TOILETS, AS REQUIRED.
GENERAL CONSTRUCTION
17. ALL STEEL FABRICATIONS TO BE PRIMED WITH BEST QUALITY RUST PROOFING PRIMER.
18. ALL POWER ACTUATED PINS/ANCHORS SHALL BE "RAMSET" #2330 AT 32" O.C. FOR INTERIOR, NON-LOAD BEARING PARTITIONS PER
ICC #ESR-1799.
19. ALL METAL FASTENERS SHALL BE MIN. HOT DIPPED GALVANIZED AFTER THEIR FABRICATION. ALL NAILS, SCREWS AND BOLTS TO BE
CORROSION RESISTANT.
20. ALL SUBSTRATES TO BE PAINTED OR OTHERWISE FINISHED, SHALL BE THOROUGHLY PREPARED AND CLEANED, AND SHALL BE
COMPATIBLE WITH PAINTS SELECTED.
21. DRYWALL CONTRACTOR SHALL PROVIDE ALL REQUIRED ACCESS PANELS WHERE NECESSARY TO PROVIDE ACCESS TO FIRE
DAMPERS, ELECTRICAL DISCONNECTS, PUMPS, VALVES, ETC. THE PAINTING CONTRACTOR WILL BE RESPONSIBLE TO PAINT ALL ACCESS
DOORS TO MATCH ADJACENT SURFACE.
22. INSTALL SUPPLEMENTARY FRAMING, BLOCKING, AND BRACING AT TERMINATIONS IN GYPSUM BOARD ASSEMBLIES TO SUPPORT
CABINETRY, FIXTURES, EQUIPMENT SERVICES
DIVISION 2
DIVISION 3
CONCRETE FLOOR REPAIRS
1. CONTRACTOR SHALL DETERMINE LOCATION OF EXISTING UTILITY LINES BELOW EXISTING FLOOR SLAB AND CONDUCT CORING FOR
CONNECTION OF NEW UTILITIES. WORK SHALL BE CARRIED OUT TO MINIMIZE DISTURBANCE TO EXISTING FLOOR SLAB. COORDINATE WITH
BEAM / REINFORCEMENT LOCATIONS. COORDINATE ALL SUCH WORK WITH PLUMBING AND ELECTRICAL SUBCONTRACTORS, AND FILL
GAPS AROUND PIPEWORK WITH FIRE RATED CAULKING / SAFING MATERIAL TO MAINTAIN 2-HOUR FIRE RATING AT CONCRETE SLAB.
PROVIDE CEMENTITIOUS FLOAT / FILL TO ENSURE NEW / EXISTING FLOORING SURFACE IS SMOOTH AND LEVEL AND APPLY MOISTURE
SEALANT AT ALL AREAS WHERE MOISTURE PRESSURE EXCEEDS FLOORING MANUFACTURER INSTALLATION RECOMMENDATIONS, AS
REQUIRED.
2. PENETRATION THRU RATED WALLS SHALL BE SEALED WITH A MATERIAL CAPABLE OF PREVENTING THE PASSAGE OF FLAMES AND HOT
GASES WHEN SUBJECTED TO THE REQUIREMENTS OF THE TEST STANDARD SPECIFIC OF FIRE STOPS ASTM-E-814 (U.L. SYSTEM #WL1001 FOR
WALLS & #CAJ1001 FOR FLOORS).
DIVISION 6
INTERIOR CABINETRY
1.INSTALL ALL ITEMIZED PREFABRICATED CABINETRY AS NOTED ON PLANS, PER MANUFACTURER'S DIRECTIONS AND MAKE ALL UTILITY
CONNECTIONS AS REQUIRED.
2.CABINET SUBCONTRACTOR TO VERIFY ALL CABINET WIDTH DIMENSIONS PRIOR TO FABRICATION. COMPLY WITH AWI STANDARDS
FOR CUSTOM GRADE AND PREMIUM GRADE FOR PLASTIC LAMINATE. SUBMIT SHOP DRAWINGS IN CONJUNCTION WITH OTHER
SUBMITTALS COVERING FABRICATION, INSTALLATION AND FINISH FOR CONFORMANCE W/ DESIGN INTENT, ETC.
3.CUSTOM CABINET INTERIORS TO BE CONSTRUCTED OF WHITE MELAMINE SURFACED HIGH DENSITY
PARTICLEBOARD, PER ANSI 208.1 GRADE M-2, EXCEPT AT AREAS BELOW SINKS, WHICH SHALL BE SURFACED WITH WHITE HIGH DENSITY
PLASTIC LAMINATE OVER 3/4" PLYWOOD. ALL EXPOSED INTERIOR EDGES TO BE COVERED WITH MELAMINE UNLESS NOTED OTHERWISE.
ALL CABINET BASES TO BE PLASTIC LAMINATE.
4.CABINET DRAWER GLIDES TO BE 100LB FULL EXTENSION GLIDES - GRANT GR 329 (OR EQUAL) GLIDE LENGTH TO BE AS REQUIRED
BY CABINET DEPTH (2"-4" SHORTER THAN OVERALL DEPTH OF CABINET.) CABINET STANDARDS TO BE KV FLUSH SHELF STANDARDS:
KV255WH72 (STEEL WHITE EPOXY COAT) WITH KV CLIPS KV256WH (STEEL WHITE EPOXY COAT), OR APPROVED EQUAL SYSTEM.
5. CABINET DOOR HINGES TO BE BLUM MODUL FULL OVERLAY 110O FULLY CONCEALED HINGE. REFER TO MANUF. SPECIFICATIONS
FOR NUMBER PER DOOR AND MOUNTING STYLE APPLICATION REQUIRED. LOCKS WHERE REQUIRED, TO BE BEST LOCKS 5L SERIES
LATCHBOLT 3/4" UTILITY CYLINDERS, SATIN CHROME FINISH. SUPPLY TWO KEYS PER LOCK. INTERIOR SURFACE HEAD AND FOOT BOLTS
TO BE 4" IVES IV40-4BR. EXCEPT WHERE PUSH-CATCHES ARE REQUIRED, DOOR AND DRAWER PULLS TO BE STANDARD 4" WIRE PULLS;
BRUSHED ALUMINUM FINISH. VERIFY W/ OWNER PRIOR TO INSTALLATION.
6. CUSTOM CABINET BODIES, DOORS, DRAWER FRONTS AND SIDE PANELS TO BE HIGH PRESSURE PLASTIC LAMINATE OVER 3/4" HIGH
DENSITY FIBERBOARD PER ANSI 208.2, EXCEPT AT ALL TOPS AND WET AREAS (SINK LOCATIONS, ETC.) WHERE 3/4 PLYWOOD SHALL BE
USED. PROVIDE PLASTIC LAMINATE TOPS AS NOTED ON CABINET ELEVATIONS. TOPS AND EDGING TO BE CHEMICAL-RESISTANT
PLASTIC LAMINATE MIN. .050" THK. PER NEMA LD-3. VERTICAL SURFACES MAY EMPLOY .028" THK. LAMINATE. GROMMETS TO BE
HAFELE - HA429.93.322 (OR EQ.) BLACK ROUND PLASTIC GROMMETS.(LOUIS & CO. (214) 647-8811). FINAL LOCATION OF
GROMMETS TO BE APPROVED BY OWNER PRIOR TO INSTALLATION
7. ALL STORAGE SHELVING TO BE 6 TIER X 12" WIDE (OR AS NOTED), CONSTRUCTED OF WHITE MELAMINE SURFACED HIGH DENSITY
FIBERBOARD. COVER EXPOSED EDGES WITH MELAMINE UNLESS NOTED OTHERWISE. INSTALL ON STANDARD METAL KNIFE-EDGE
BRACKETS SET ON VERTICAL STANDARDS @ MIN. 24" ON CENTER.
8. REFER TO FINISH SCHEDULE ON THIS SHEET FOR ALL LAMINATE AND COUNTERTOP FINISH SELECTIONS, ETC.
DIVISION 7
INSULATION AND SEALANTS
1. PROVIDE INSULATION WITH FIRE PERFORMANCE PER TEST METHODS ASTM E 84, ASTM E 119 AND ASTM E 136.
2. FOR ALL INTERIOR WALLS FULL HT. TYPE I (BLANKETS WITHOUT MEMBRANE FACING), AS USG
"THERMAFIBER" OR EQUAL HAVING BEST SOUND DEADENING PROPERTIES (MIN. R-11).
3. INTERIOR PLUMBING FIXTURES; 1- PART SANITARY, MILDEW RESISTANT, AS DOW CORNING 786 OR EQ.
4. R-11 FOR MISSING WALL INSULATION. INSULATION TO COMPLY WITH ASTM C 665 FOR TYPE III, CLASS A : BLANKETS WITH KRAFT
MEMBRANE FACING. SET FACED UNITS WITH KRAFT TOWARDS OUTSIDE.
5. SEALANT FOR THRESHOLDS; SINGLE COMPONENT POLYSULPHIDE, BY PECORA, DAP, OR EQUAL.
6. INTERIOR PAINTED AREAS; ACRYLIC LATEX CAULK BY TREMCO, OR EQUAL.
7. INTERIOR CABINETRY AND VINYL WALL COVERING;1-PART SILICONE AS DOW CORNING 795 OR EQ.
8. INTERIOR PLUMBING FIXTURES;1- PART SANITARY, MILDEW RESISTANT, AS DOW CORNING 786 OR EQ.
ROOFING REPAIRS
9. MAKE ALL REQUIRED REPAIRS AT NEW PENETRATIONS, EQUIPMENT-MOUNTINGS, ETC. OR ESTABLISHED LEAKS OR DETERIORATED
AREAS, USING 4-PLY CLASS A / I-60 BUILT-UP ASPHALT/ PLY SYSTEM WITH WHITE (GRANULAR) CAP SHEET TO MATCH EXISTING SYSTEM.
FIELD VERIFY AND REPORT TO ARCHITECT ON ALL PRE-EXISTING NEGATIVE ROOFING CONDITIONS: ACCOUNT FOR THIS WORK AS A
PART OF YOUR BID. CONTRACTOR MAY SLIT MEMBRANES IF PROPER PATCHES ARE PROVIDED. DURING ROOFING REPAIR
OPERATIONS PROVIDE PROTECTIONS TO ENSURE AGAINST BITUMEN SPILLS ON SIDING OR PAVING BELOW. CLEAN UP ANY SPILLS OR
SPATTERS IMMEDIATELY.
10. EXTEND ALL NEW VENT PIPES TO 12" ABOVE SHEATHING. ADD METAL FLASHING COLLARS TO ALL NEW PIPES AFTER COMPLETION
OF BUILT UP ROOFING REPAIRS.
11. PROVIDE 22 GAGE GALVANIZED SHEET METAL FLASHINGS, WITH PAINT FINISH AT ROOF EDGES, ETC.
DIVISION 8
INTERIOR WINDOWS / VISION PANELS
1. SUBMIT SHOP DRAWINGS IN CONJUNCTION WITH OTHER SUBMITTALS COVERING FABRICATION, INSTALLATION AND FINISH FOR
CONFORMANCE W/ DESIGN INTENT, ETC. VERIFY QUANTITIES AND SIZES PRIOR TO ORDERING.
2. INTERIOR WINDOWS SHALL BE SINGLE GLAZED WITH 1/4" THICK, CLEAR TEMPERED PANES WITH TINTS, FILMS, ETC. OR OTHER SPECIAL
GLAZING PRODUCTS AS SPECIFIED AND NOTED ON THE PLANS. NON-RATED GLAZING SHALL BE SET IN HIDDEN C-CHANNEL
ALUMINUM FRAMES AND STOPS.
INTERIOR DOORS
4. CONTRACTOR TO COORDINATE AND REVIEW DOOR SUBMITTALS (INCL. HARDWARE SCHEDULES) FOR CONFORMANCE WITH
DESIGN INTENT, ETC. VERIFY QUANTITIES/ SIZES PRIOR TO ORDERING.
5a. INTERIOR DOORS TO BE 'WESTERN INTEGRATED' FLUSH SLAB SOLID CORE, WOOD DOORS, WITH FINISH AS DIRECTED IN THE FINISH
SCHEDULE. INTERIOR FRAMES SHALL BE EITHER 'WESTERN INTEGRATED' KNOCK-DOWN METAL FRAME, COLOR: BLACK ANNOD.
INCLUDING CLEAR ALUM SNAP-ON TRIM OR EZYCONCEPTS EZYJAMB FLUSH METAL FRAME SYSTEM W/ MUD EDGE. NO TRIM.
5b. INTERIOR VISION PANELS IN DOORS TO BE GLAZED W/ 1/4" THICK, CLEAR TEMPERED GLASS (OR LEADED) PER SCHEDULE. ALL
FRAMES AND STOPS TO BE PAINTED STEEL.
6. WINDOWS AND ENTRY / EXIT DOORS TO REMAIN WHERE EXISTING. ANY REPLACEMENTS SHALL MATCH EXISTING: PROVIDE
BUILDING STANDARD DOORS, PRE-FINISHED CLEAR, OR COLOR AS DIRECTED BY LANDLORD. ENTRY DOOR FRAMES SHALL BE PROFILE,
STYLE AND FINISH AS DIRECTED BY LANDLORD.
7. MOUNT HARDWARE UNITS AT HEIGHTS INDICATED IN FOLLOWING APPLICABLE PUBLICATIONS, EXCEPT AS SPECIFICALLY INDICATED
OR REQUIRED TO COMPLY WITH CBC GUIDELINES AND CBC 1008.1.8 AND HANDICAP ACCESSIBILITY REGULATIONS
1. "RECOMMENDED LOCATIONS FOR BUILDERS HARDWARE FOR STANDARD STEEL DOORS AND FRAMES" BY THE DOOR AND
HARDWARE INSTITUTE.
8. WHERE CLOSERS ARE INDICATED FOR DOORS REQUIRED TO BE ACCESSIBLE TO THE PHYSICALLY HANDICAPPED, PROVIDE
ADJUSTABLE UNITS COMPLYING WITH ANSI A117.1 PROVISIONS FOR DOOR OPENING FORCE AND DELAYED ACTION CLOSING. FINISH
TO MATCH SPRAYED LAQUER US26D. ADJUST UNITS TO COMPLY WITH CBC PROVISIONS FOR DOOR OPENING FORCE AND DELAYED
ACTION CLOSING.
9. PROVIDE CBC APPROVED ALUM. / VINYL TRANSITION STRIPS AT DOORWAYS BETWEEN FLOORING OF
DIFFERENT TYPES. SEE ARCHITECT'S DETAIL.
10. AS REQUIRED BY MECHANICAL ENGINEER, UNDERCUT RESTROOM DOOR 1-1/2 FOR AIR CONDITIONING TRANSFER.
11. EQUIP LOCKS WITH INTERCHANGABLE CORE PIN TUMBLER INSERTS. PROVIDE 6-PIN CYLINDER HDWR. WITH 2 KEYS FOR EACH
LOCK. PROVIDE 2 MASTER KEYS.
12. PROVIDE SUBMITTAL DOCUMENTS FOR ALL HARDWARE REFERENCED TO EACH DOOR. HINGES TO BE 4-1/2" X 4-1/2" HINGE CO.;
LOCKS SHALL BE SCHLAGE AL / SPARTA D SERIES. MATCH EXISTING WHERE NECESSARY. PROVIDE MANUF. CATALOGUE CUTS FOR
OWNER SELECTION.
13. INTERIOR STOREFRONT GLASS DOORS (AND DOOR SIDELIGHT) TO BE 1/4" THICK SINGLE GLAZED, CLEAR TEMPERED.
14. SPECIALTY HARDWARE TYPES TO BE AS FOLLOWS:
STOREFRONT ENTRIES:
STOREFRONT HINGES / PIVOTS,
12" 'D' PULLS,
O/H DOOR CLOSER,
DEADLOCK: ADAMS RITE D.R. MS 1850, MS 4043, OR MS 4002, OR EQ.
WEATHER-STRIPPING, THRESHOLD AND STOPS
15.FINISH: PROVIDE POLISHED CHROME FINISH FOR ALL HARDWARE. HINGES TO BE MIN. 4" X 4" AS HAGER HINGE CO. OR EQUAL.
LOCKSETS TO BE SCHLAGE TRE-PLY DESIGN. STOPS, GASKETS (S88D), AND WEATHER -STRIPPING TO BE PEMKO MANUF. INC. PROVIDE
3 RUBBER SILENCERS PER SINGLE DOOR.
STOREFRONT WINDOWS & DOORS
16. SUBMIT SHOP DRAWINGS COVERING FABRICATION, INSTALLATION AND FINISH.
CONTRACTOR TO COORDINATE AND REVIEW SUBMITTALS (INCL. HARDWARE SCHEDULES) FOR
CONFORMANCE W/ DESIGN INTENT, ETC. VERIFY QUANTITIES AND SIZES PRIOR TO ORDERING.
17. ALL NEW STORREFRONT WINDOWS AND DOORS TO BE KAWNEER TRIFAB 400 SERIES
STOREFRONT SYSTEM, CENTER PLANE 1 ¾" X 4" WITH BLACK ANODIZED ALUMINUM FINISH.
VERIFY FINISH WITH ARCHITECT PRIOR TO FABRICATION. PROVIDE MANUFACTURER'S
STANDARD COLOR AND FINISH SAMPLES FOR ARCHITECT SELECTION.
18. ALL NEW STOREFRONT DOORS TO BE IR 350 ENTRANCE DOORS AS SUPPLIED BY KAWNEER
INC. -UNITS TO BE FACTORY PRIMED AND FINISHED, AS NOTED ON SCHED. INSTALL PER
MANUFACTURER'S INSTRUCTIONS, FOR WEATHERTIGHT INSTALLATION. COORDINATE WITH
STUCCO AND PAINT.
19. CONTRACTOR TO COORDINATE AND VERIFY QUANTITIES AND SIZES PRIOR TO ORDERING.
PROVIDE SUBMITTALS FOR ARCHITECT REVIEW.
20. ALL EXTERIOR WINDOWS SHALL BE SINGLE GLAZED WITH PANE OF PPG UV-PROTECTED,
LOW-E CLEAR GLASS 1/4" THICK, WITH TEMPERED PANES AS NOTED ON THE ELEVATIONS.
PROVIDE GLASS ASSEMBLIES WITH THE FOLLOWING MINIMUM VALUES: U-FACTOR = 1.190,
SHGC = 0.830
DIVISION 9
METAL STUD FRAMING AND GYPSUM BOARD
1. PROVIDE FRAMING COMPONENTS OF SIZES INDICATED TO COMPLY WITH ASTM C 754 . ALL METAL COMPONENTS TO HAVE G40
HOT-DIP GALVANIZED COATING PER ASTM A 525. PROVIDE SIZES AND GRADES INDICATED. ALL METAL FASTENERS TO BE CORROSION
RESISTANT.
2. ALL METAL WALL STUDS, INCLUDING SMOKE SEALED WALLS SHALL BE 16" ON CENTER, EXTENDING TO UNDERSIDE OF EXISTING GYP.
BD. PLENUM CEILING. WHERE FPAINTED GYP. BD. FINISH IS INDICATED, INSTALL 5/8" GYPSUM WALLBOARD (LEAD-LINED AS REQ'D.)
SCREWED TO 1/2" RESILIANT CHANNEL FURRING AT 16" O.C., WITH MAXIMUM SCREW SPACING OF 7". PARTITIONS INDICATED FULL HT.
ARE APPROX. 8'-0" HT. PROVIDE FIRE-RATED SEALANT CONT. AT TOP OF RATED WALLS. ISOLATE STEEL FRAMING FROM BUILDING
STRUCTURE TO PREVENT TRANSFER OF LOADING IMPOSED BY STRUCTURAL MOVEMENT. WALLS INDICATED SMOKE / SOUND SEALED
SHALL BE SET ON DOUBLE CONTINUOUS BED SEALANT.
3. STUD WALLS SHALL HAVE CONT. 20 GA. SHEET METAL BACKING AND HORIZONTAL BLOCKING WHERE WALL-HUNG CABINETS /
EQUIMENT INDICATED. PROVIDE DOUBLE 20 GA. STUDS AT ALL DOOR JAMBS.
4. ALL VERTICAL DRYWALL CORNERS / EDGES SHALL BE CONSTRUCTED WITH SQUARE METAL DRYWALL TRIM BEADS, TO BE
COORDINATED WITH PLANT-ON CORNER PROTECTION AS REQUIRED.
5. INTERIOR PARTITIONS: 1 LAYER 5/8" GYPSUM BOARD EACH SIDE 3 5/8" X 25 GAGE METAL STUDS AT 16" ON CENTER, EXCEPT THAT
WATER-RESISTANT GYP. BD. IS REQUIRED AT PLUMBING WALLS. REPAIRS TO DEMISING WALLS SHALL INCLUDE R-11 INSULATION.
6. ALL DRYWALL SHALL BE FINISHED WITH A SMOOTH TEXTURE.
SUSPENDED CEILING (NON-RATED OPEN PLENUM)/ T-BAR CEILINGS
7. APPLY ACOUSTICAL SEALANT IN A CONTINUOUS RIBBON CONCEALED ON BACK OF VERTICAL LEGS OF EDGE MEMBERS, AT
PRIVATE OFFICE ONLY.
8. PROVIDE ACM-7 CLIPS ETC. FOR ATTACHING HANGERS WITH CAPABILITY TO SUSTAIN A LOAD 10 TIMES THAT OF CEILING
CONSTRUCTION, PER ESR 1222. WIRE FOR HANGERS AND TIES: ASTM C636, CLASS 1 ZINC COATING, SOFT TEMPER. DO NOT ATTACH
HANGERS TO CONC. FLOOR DECK OR STEEL DECK TABS. ATTACH HANGERS TO STRUCTURAL MEMBERS. SPACE HANGERS MAX. 48"
O.C. AND NOT MORE THAN 8" FROM ENDS OF EACH MEMBER.
9. SUSPENSION SYSTEM FOR INTERIOR CEILINGS: USG DONN DX/DXL SUSPENDED T-BAR CEILING SYSTEM SET AT HEIGHTS SHOWN ON
CEILING PLAN, PER ASTM C 635 (MANUFACTURER'S STANDARD DIRECT-HUNG SUSPENSION SYSTEM FOR SUSPENDED GYPSUM BOARD
CEILINGS). MAIN BEAMS AND CROSS FURRING MEMBERS INCLUDING SEISMIC SPLAY-BRACING AND VERTICAL STRUTS THAT ARE
CROSS CONNECTED TO FORM A MODULAR SUPPORTING NETWORK.
10. CEILING TILES: WHITE 9
16" X 24" X 24" NON-FIRE-RESISTANCE-RATED, WATER-FELTED, MINERAL-BASE TILE: TYPE III, FORM 2 ACOUSTICAL
TILES PER ASTM E 1264 IN ALL T-BAR LOCATIONS, AS 'ASTRO-CLIMA PLUS W/ RABBETED EDGE, OR EQUIVALENT. MATCH EXISTING
WHERE POSSIBLE.
13. STANDARD FOR CEILING SUSPENSION SYSTEM INSTALLATIONS: COMPLY WITH ASTM C 636 AND CBC 2506.2.1. CONFORM TO THE
LAYOUT SHOWN ON REFLECTED CEILING PLANS. SCREW EDGE SUPPORTS TO SUBSTRATE AT 16" O.C. AND AT 3" FROM ENDS,
LEVELING WITH CEILING SUSPENSION SYSTEM TO A TOLERANCE OF 1/8" IN 12 FEET. MITER CORNERS ACCURATELY AND CONNECT
SECURELY. DO NOT USE EXPOSED FASTENERS.
PAINTING / FINISHING
14. CONTRACTOR TO ENSURE ALL FINISH MATERIALS WILL BE FLUSH AND WASHABLE. INTERIOR FINISH TO CONFORM TO
REQUIREMENTS OF CBC 803.5 FLAME SPREAD INDEX 200 MAX. SMOKE DENSITY RATING 450 MAX. ALL DECORATIVE MATERIALS SHALL
BE MAINTAINED IN A FLAME RETARDANT CONDITION. ALLOW FOR 3-COLOR INTERIOR PAINT SCHEME, PER IPS #11 ENAMEL AND IPS
#9 EPOXY PAINT IN PROCEDURE ROOM, RE-USE ROOM, JANITOR AND MED WASTE ROOMS.
15. ALL FINISHED SURFACES SCHEDULED FOR PAINTING TO BE CLEAN AND FREE OF SURFACE DEFECTS AND READY FOR PAINTING.
ALL DRYWALL TO BE TAPED, FLOATED, SANDED AND FINISHED WITH A SMOOTH TEXTURE. INTERIOR PAINTING MAY BE APPLIED BY
BRUSH, ROLLER, OR SPRAY RIG METHOD ACCORDING TO MANUFACTURER'S SPECIFICATIONS. PAINT SPECS ARE BASED ON VISTA
CAREFREE PAINTS, BUT EQUALS ARE ACCEPTABLE (ALL PAINT COLORS TO BE AS SELECTED BY ARCHITECT/ OWNER) AS FOLLOWS:
INTERIOR PAINTS & CLEAR WOOD FINISH:
DRYWALL
PRIMER- 1 COAT PVA (USG DRYWALL PRIMER)
FINISH- 2 COATS - LATEX ACRYLIC EGGSHELL ENAMEL
PAINTED WOODWORK
PRIMER - 1 COAT - LATEX ENAMEL
FINISH- 2 COATS - SEMI GLOSS LATEX ACRYLIC ENAMEL
CLEAR WOOD FINISH
STAIN - 1 COAT, INTERIOR STAIN
FINISH - 2 COATS SATIN FINISH VARNISH
SAND LIGHTLY BETWEEN COATS
VINYL WALL COVERING
16. WHERE INDICATED, PROVIDE VINYL WALLCOVERING AT SELECTED FOR ACCENT WALLS, ETC. COMPLY WITH FS CCC-W-408,
CLASS A, MEDIUM DUTY MIN. 19 OZ: TYPE II 54" WIDTH. REFER TO FINISH SCHEDULE AND VERIFY SELECTION WITH OWNER. USE MILDEW
RESISTANT, NON-STAINING, STRIPPABLE ADHESIVE COMPATIBLE WITH COVERING SELECTED.
FLOORING
17. COORDINATE DELIVERY AND INSTALLATION OF OWNER-SUPPLIED GLUE-DOWN COMMERCIAL CARPET AS SPECIFIED IN THE
MATERIALS AND COLOR SCHEDULE. ALLOW SUFFICIENT TIME FOR VERIFICATION THAT ACTUAL SELECTION IS AVAILABLE.
CONTRACTOR SHALL INSTALL SCHEDULE BASE MATERIAL AFTER CARPET INSTALLATION.
18. SHEET VINYL FLOORING SHALL BE COMMERCIAL GRADE PRODUCT, AS SPECIFIED ON THE FINISH SCHEDULE: ALLOW OWNER TO
CONFIRM SELECTION PRIOR TO ORDERING.
19. PROVIDE MIN. 3 COATS MANUFACTURER-RECOMMENDED FINISH WAX TO ALL NEW SHEET VINYL FLOORS. CLEAN AND BUFF
FINISHED INSTALLATIONS.
20. TILE WHERE REQUIRED SHALL BE PORCELAIN CERAMIC TILE,, THINSET OVER LEVELLING COMPOUND. ALLOW FOR SETTING OF
INDIVIDUAL TILE ACCENTS & LINERS PER ELEVS.
1
A5.0
SPECIFICATIONS
SCALE: NTS
A-5.0
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
SHEET NO.
2509
REVISIONS:
5/30/2025DATE:
PROJECT NO.
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
S
a
n
t
a
A
n
a
,
C
A
9
2
7
0
4
21. SUB-CONTRACTORS SHOULD FULLY INFORM THEMSELF WITH THE WORK INVOLVED AND FIELD CONDITIONS. ALL SUBSTRATE
PREPARATION AND ANY REQUIRED CEMENTITIOUS FEATHERING / FLOATING SHALL BE INCLUDED. TEST CONCRETE SLAB SUB-STRATES
FOR MOISTURE OFF-GASSING PRIOR TO INSTALLATION OF FLOORING AND PROVIDE MANUF. RECOMMENDED SEALANTS WHERE
EXCEEDING INDUSTRY AND MANUF. MAX. RECOMMENDED MOISTURE LEVELS.
22.WHERE SHEET VINYL INDICATED PROVIDE INTEGRAL COVED BASE. ENSURE TIGHT FIT AT JUNCTION OF FLOOR AND WALLS.
PROVIDE 4" RUBBER BASE FOR OTHER TOP-SET INSTALLATIONS AT ALL AREAS SCHEDULED FOR CARPET (WAITING ROOM,
HALLWAYS ETC.).
STUCCO
23. APPLY BASE AND TOP COATS EXTERIOR PLASTER ("STUCCO") ON GALVANIZED EXPANDED METAL LATH ON SEALED, TAPED
DUPONT TYVEK STUCCO WRAP, PER ICBO RPT. 4000. APPLY 2 LAYERS TYVEK STUCCOWRAP OVER PLYWOOD SHEATHED SHEAR
WALLS. APPLY FINISH COLOR ADDITIVE TO ALL FINISH STUCCO MIXES TO ACHIEVE EVEN CONSISTANT FINISH COLOR. USE LA
HABRA COLOR STUCCO MIX OR EQUAL APPROVED, IN MANUFACTURER'S STANDARD COLOR, TO BE VERIFIED WITH OWNER.
INSTALL STRICTLY PER MANUF.'S INSTRUCTIONS TO ACHIEVE SMOOTH "LIGHT SAND" TEXTURE. USE PRIMERS AS REQUIRED.
DIVISION 10
SPECIALTY PRODUCTS
1. SCHEDULE OF BATHROOM SPECIALTIES:
A.TOILET GRAB BAR 36"x42"x1 1/2" DIA. S/STEEL:BOBRICK B-6897, OR EQUAL (QTY: 2)
C.TOILET PAPER HOLDER/SEAT DISPENSER:BOBRICK B-2840, OR EQUAL (QTY: 2)
D.LIQUID SOAP DISPENSER:BOBRICK B-306, OR EQUAL (QTY: 2)
E.LED MIRROR :BOBRICK B-169 SERIES, OR EQUAL (QTY: 2)
F.COMBO TRASH / TOWEL RECEPTACLE:BOBRICK B-36903 (QTY: 2)
G.TOWEL DISPENSER:BOBRICK B-4262 (QTY: 6)(CONFIRM LOCN. W/ OWNER)
H.LAVATORY TRAPS/ PIPE INSULATION:TRUEBRO INC. PRE-MOULDED PIPE WRAP (WHITE) HANDI LAV-GUARD" #102
(QTY. 5)
4. FIRE EXTINGUISHERS / CABINETS: 10 LBS TYPE ABC DRY CHEMICAL, WITH 18 GA. SEMI-RECESSED CABINET WITH PAINTED FINISH,
GLASS DOOR AND LOCK, AS POTTER-ROEMER, INC.
WINDOW COVERINGS
6. PROVIDE VERTICAL WINDOW COVERINGS AT EACH EXISTING EXTERIOR WINDOW AS SPECIFIED BELOW. CONFIRM STYLE, ETC. W/
OWNER PRIOR TO ORDERING:
MECHOSHADE THERMOVEIL 1300 SERIES DENSE BASKET WEAVE SHADECLOTH, COLOR: 1320 SHADOW GREY
DIVISION 15
PLUMBING NOTES:
1. READ W/ MECHANICAL PLUMBING SPECIFICATION DRAWINGS.
2. ALL PLUMBING SHALL BE IN ACCORDANCE WITH CPC AND ALL LOCAL CODES AND ORDINANCES.
3. CONTRACTOR TO COORDINATE EQUIPMENT CONNECTIONS WITH ALL OTHER TRADES AND
SUPPLIERS. INSTALL AND MAKE FINAL CONNECTIONS, FURNISHING CUT-OFF VALVES, P-TRAPS, P.R.V.'S AND PIPING AS REQUIRED.
3A. INSTALL SHOCK ABSORBERS IN COLD WATER LINES, AS REQUIRED
4. CONNECT TO EXISTING VENT AND WASTE STACKS WHERE POSSIBLE. CAREFULLY COODINATE WORK IN FLOOR WITH LOCATION OF
EXISTING UTILITIES. DO NOT DISTURB ADJACENT BUILDINGS DURING WORKING HOURS.
5. HOT WATER SUPPLY TO BE CONNECTION TO NEW ELECTRICAL WATER HEATER, OR AS NOTED ON PLUMBING PLANS.
6. ALL PIPEWORK SHALL BE CONCEALED IN STUD WALLS ETC. STUB-OUTS SHALL BE MIN. 6" AFF.
7. HOT AND COLD WATER PIPING SHALL BE 1/2" DIA. COPPER TYPE "L" PER ASTM B88, INSULATED WITH 1" FIBERGLASS, WITH VAPOUR
SEAL ON COLD WATER PIPING. SLEEVE ALL NEW UNDERGROUND PIPING.
8. CONDENSATE DRAIN PIPING SHALL BE TYPE "L" COPPER WITH 1" FIBERGLASS INSULATION.
9. DRAIN LINES TO BE NO SMALLER THAN STUB-OUT OF FIXTURE ITSELF, OR MIN. 1 1/2" DIA.
10. SCREWED PIPE SHALL BE MADE UP WITH PIPE COMPOUND APPLIED TO MALE THREAD, WITH NOT MORE THAN 2 THREADS LEFT
EXPOSED. PIPES SHALL BE REAMED AFTER THREADING.
11. COPPER JOINTS SHALL BE MADE UP WITH 95-5 SOLDER.
12. CLEAN-OUTS SHALL BE AS MANUF. JOSAM ZURN MANUF. CO., OR EQUAL, AND SHALL BE INSTALLED AT ALL BENDS ANGLES AND
ENDS OF WASTE AND SEWER LINES. ALL CLEAN-OUTS SHALL BE BROUGHT TO FINISHED FLOOR LEVEL AND SHALL BE PROVIDED WITH
SUFFICIENT SPACE FOR RODDING.
13. ALL VALVES SHALL BE BRASS, MANUF. BY CRANE, NIBCO, STOCKHAM, LUNKENHEMER, NORDSTRON, GRINNELL OR EQUAL.
14. PROVIDE GATE VALVES ON ALL WATER LINES.
FIRE SPRINKLER SYSTEM:
1. PLANS FOR MODIFICATIONS TO FIXED FIRE PROTECTION EQUIPMENT SHALL BE PREPARED AND SUBMITTED TO THE OWNER &
ARCHITECT BY INSTALLING CONTRACTOR AND SHALL BE APPROVED BY THE FIRE PREVENTION BUREAU, OWNER'S INSURANCE
ORGANIZATION AND ARCHITECT PRIOR TO INSTALLATION. SPRINKLER CONTRACTOR SHALL BE NOMINATED BY LANDLORD (ONLY).
2. COMPLY WITH NFPA 13 AND 24 "STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS. THE BUILDING'S AUTOMATIC
SPRINKLER SYSTEM SHALL COMPLY WITH THE U.B.C. STANDARD NO. 38-1, COMBINED SYSTEM.
3. COMPLY WITH NFPA 70 "NATIONAL ELECTRICAL CODE" FOR ELECTRICAL CONNECTIONS BETWEEN WIRING AND ELECTRICALLY
OPERATED DEVICES.
4. VERIFY EXISTING UTILITY LOCATIONS. INSTALL DETECTOR CHECK VALVES AS REQUIRED. COMPLY WITH NFPA 26 FOR DEVICES AND
METHODS OF VALVE SUPERVISION.
5. INSTALL FULLY CONCEALED HEADS IN ALL AREAS, EXCEPT SEMI-RECESSED CHROME FINISH HEAD WITH WHITE FINISHED
ESCUTCHEON MAY BE USED IN ELECTR. UTILITY ROOMS ONLY.
DIVISION 16
SEE ELECTRICAL SPECIFICATIONS. ON SEPARATE DRAWINGS
1. COORDINATE WITH LANDLORD'S FIRE ALARM SUB-CONTRACTOR. THE FIRE ALARM SYSTEM SHALL CONFORM TO ARTICLE 760
CALIFORNIA ELECTRICAL CODE.
DIVISION 16
SEE ELECTRICAL SPECIFICATIONS. ON SEPARATE DRAWINGS
LIGHT FIXTURES:
UNLESS DIRECTED OTHERISE; 2' X 4' INDIRECT LUMINAIRE, PERFORATED LIGHT SHIELD, CENTERMOUNT CONFIGURATION, STANDARD
WHITE - SEE E-SERIES PLAN / SPECS
LIGHT SWITCH: LEVITON #5501, WHITE
ELECTRICAL WALL OUTLET:
1.LEVITON DUPLEX OUTLET #5242, 20A, 120V, WHITE OR RED FOR EMERGENCY POWER OUTLETS
ELECTRICAL WALL OUTLET - DEDICATED:
1.LEVITON DUPLEX OUTLET #5242, 20A, 120V, WHITE
TELEPHONE BACKBOARD:
1.4'-0" X 4'-0" ¾" CDX PLYWOOD BACKBOARD
2.TELEPHONE FEEDER
3.ONE DEDICATED 110V DUPLEX OUTLET
1
A5.1
SPECIFICATIONS
SCALE: NTS
A-5.1
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
SHEET NO.
2509
REVISIONS:
5/30/2025DATE:
PROJECT NO.
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
S
a
n
t
a
A
n
a
,
C
A
9
2
7
0
4
3
A-6.0
TYP. CEILING DETAIL
SCALE: 1-1/2"=1'-0"
5/8" TYPE 'X' GYP. BD. EA. SIDE 3 5/8"
X 25 GA. MTL. STUD FRAMING AT 16"
O.C. - PROVIDE MIN. 3- #10 SHEET
MTL SCREWS AT EACH CNR. / JNT.
3'
-
0
"
M
A
X
.
3 5/8" X 20 GA. MTL. DIAG.
BRACING AT 48" O.C. MAX.
ATTACH TO STRUCT. SOFFIT
SCREW JOIST TO VERT.
STUD W/ 3- #10 SMS AT
16" O.C.
20 GA. X 3-5/8" MTL. STUD
AT 16" O.C.
TYP. HARD-LID CL'G:
" TYPE 'X' GYP. BD. ON
3-5/8" X 20 GA. MTL.
STUD JOISTS AT 16" O.C.
MAX. SPAN 11'-0" - FOR
GREATER SPANS (UP TO
16'-0") ADD VERT. TIE TO
STRUCTURE ABOVE - ICC
ESR-1538
TOP TRACK - ATTACH AT 24"
O.C. MAX W/2 #10 SCREWS,
(TYP.)
25 GA. MTL. STUDS AT 16" O.C.
EXTEND UP TO BLK. ABOVE -
ATTACH W/ 2 #10 S.M.S. PER
CONN.
EXIST. U/S ROOF
STRUCT.
SCREW TRACK TO VERT.
STUD W/ 2- #10 SMS AT
16" O.C.
20 GA. X 3-5/8" MTL. STUD
AT 16" O.C.
TYP. HARD-LID CL'G:
" TYPE 'X' GYP. BD. ON 3-5/8" X 20 GA.
MTL. STUD JOISTS AT 16" O.C. MAX.
SPAN 11'-0" - FOR GREATER SPANS (UP
TO 16'-0") ADD VERT. TIE TO STRUCTURE
ABOVE - ICC ESR-1538
20 GA. MTL. STUD
NOTCHED @
VERT. STUDS @ 16"
O/C
TENANT WALL
CONDITION
TYP. INTERIOR
CONDITION
CEILING SYSTEM PER
CBC 2506.2.1 & ASCE 7-10
ICC ESR-1222
8 GA. HANGER WIRE AT
48" O.C. MAX. THIS
ATTACHMENT TO BE
CAPABLE OF
SUPPORTING MIN. 200
LBS. INCLUDE 4 TURNS IN 1
1/2" MAX. EA. WIRE END
(TYP.)
2"
12 GA. SPLAY BRACING
WIRES IN 4 DIRECTIONS AT
12" O.C. EA. WAY, 4 FT.
MAX. FROM WALL. ENSURE
MIN. 6" CLEARANCE FROM
ALL HORIZ. PIPEWORK
AND DUCTS. INCLUDE 4
TURNS IN 1 1/2" MAX. EA.
WIRE END (TYP.)
SUSPENDED T-BAR CEILING
SYSTEM: HEAVY DUTY 2
1/2" X 20 GA. MAIN
RUNNERS AT 48" O.C. /
3/4" CROSS FURRING MBRS
(GRID) AT 24" O.C.
COMP. STRUT OR 20
GA. MTL. STUD AT 12"
O/C EA. WAY
CONT. MTL. TRACK
8" MAX.
4"
9'
-
0
"
3'
-
0
"
M
A
X
.
MAIN RUNNER
24" X 24" ACOUSTIC TILE
45 DE
G
.
5/8" TYPE 'X' GYP. BD. EA.
SIDE 4" X 20 GA. MTL. STUDS
AT 16" O.C.
6
A6.0
SUSPENDED CEILING - ATTACHED
1 1/2"=1'-0"
GYP. BD. TO ABOVE
HIGHEST ADJ. CLG.
EXIST. U/S ROOF
STRUCT.
TOP - ATTACH AT 24"
O.C. MAX W/3 #10
SCREWS PER CONN.
7 8"
ATTACH CLG. GRID
W/ POP RIVETS @
ATTACHED WALLS
NOTE: SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH ASTM C635, ASTM C636,
AND ASTM E580, SECTION 5 - SEISMIC DEISNG CATEGORIES D, E AND F. ASCE7-SECTION 13.5.6.2.2
7
A6.0
SUSPENDED CEILING - UNATTACHED
N.T.S.
ACOUSTICAL TILE
7 8" PERIMETER TRIM
HEAVY DUTY T-BAR
MAIN OR CROSS RUNNER
#12 GA. WIRE @ 4'-0"o.c.
W/ 3 FULL TURNS IN 1 1/2"
#16ga. TIE WIRE OR MTL.
STRUT BETWEEN ENDS OF
MEMBERS W/ POSITIVE
CONNECTION TO PREVENT
SPREADING
2 #10 S.M.S. @ 16"o.c. FOR 2X
METAL STUD WALLS
NOTE:
1. MAX. WIRE SLOPE 45° W/ 3 FULL TURNS AT RUNNER. TYP. AT ALL
HANGERS.
2. SPRINKLER HEADS/PENETRATIONS SHALL HAVE A 2" OVERSIZE
RING/SLEEVE TO ALLOW FREE MOVEMENT ON AT LEAST 1"
INTERIOR
FINISH
3/4"
CLEAR
1/4" LENGTH
OF END T-BAR
OR 8" MAX.
1
1
/
2
"
BRC-2 CLIPS PER ESR 1222
NOTE
1. FOR CEILING AREAS EXCEEDING 144
SQ. FT. (12' O.C./6' FROM NEAREST
WALL) HORIZ. RESTRAINT OF SYSTEM TO
BE TIED DIRECTLY TO STRUCTURAL WALL
/ ROOF SYSTEM. RIGIS BRACES
PERMITTED IN LIEU OF DIAG. SPLAY
WIRES.
USG DONN DX/DXL HEAVY DUTY
SUSPENSION SYSTEM - 9
16" TEE SERIES
CEILING SYSTEM PER
CBC 2506.2.1 & ASCE 7-10
ICC ESR-1222
NOTE: SPRINKLER
HEADS/PENETRATIONS SHALL HAVE A
2" OVERSIZE RING/SLEEVE TO ALLOW
FREE MOVEMENT ON AT LEAST 1"
CABLE TRAYS AND ELEC. CONDUITS
SHALL BE SUPPORTED INDEPENDENTLY
OF CLG.
PROVIDE SPECIAL INSPECTION PER
ICC REPORT
LATERAL FORCE BRACING IS REQ.
FOR ALL CLG. AREAS
CEILING TILE: USG ASTRO CLIMA PLUS
- WHITE - TEGULAR 9
16" - 24"x24"
STRUCTURAL DECK
FULLY RECESSED
LIGHT FIXTURE
SUSPENDED T-BAR CEILING SYSTEM:
SEE DETAILS 6A-6.0 & 11A-6.0
3" MAX.
8 ga. HANGER WIRE AT 48"
o.c. MAX.THIS ATTACHMENT
TO BE CAPABLE OF SUPPORT.
MIN. 200 LBS. INCLUDE 4
TURNS IN 1 1/2" MAX. EA.
WIRE END (TYP.)
10
A-6.0
LIGHT FIXTURE
N.T.S.
NOTES PER ASCE 7 SECTION 13.5.6.2.2 CISCA:
FIXTURES WEIGHING LESS THAN 56 LBS USE 2 SLACK 12 GA. SAFETY
WIRES AT DIAGONAL CORNERS
FIXTURES WEIGHING MORE THAN 56 LBS USE 4 TAUT 12 GA. WIRES
(1 EA. CORNER) ATTACHED TO STRUCTURE ABOVE -ENSURE WIRES
CAN SUPPORT 4X WEIGHT OF FIXTURE.
12ga. BRACING WIRE @ 12'-0"o.c.
EA. WAY W/ 4 TIGHT TURNS IN 1
1/2" BOTH ENDS OF WIRE (TYP.)
ATTACH STRUT TO CROSS RUNNE
W/#14 S.M.S. MAX. 2" FROM
MAIN RUNNER
2" (MAX.) FROM BRACING WIRE TO
CROSS RUNNERS
2x BLKG. W/"SIMPSON" (A35), EA.
END, EA. SIDE (WHERE REQUIRED)
#12 GA. VERTICAL WIRE HANGER
3/4" RIGID MTL. ELEC. CONDUIT,
CRIMP BOTH ENDS & ATTACH TO
JOIST OR 2X BLK. W/#4 F.H.W.S.
CROSS RUNNERS
(MAX.)
45°MAIN RUNNERS45°
(MAX.)
NOTE:
SEISMIC BRACING SHALL BE
INSTALLED 12'-0"o.c. MAX. EA.
WAY EXTENDED TUBE TO BE
TIGHT TO CEILING GRID &
STRUCTURE ABOVE.
ROOF/CEILING
STRUCTURAL MEMBER
9
A-6.0
SPLAYED WIRE SYSTEM & COMPRESSION STRUT
N.T.S.
8
A6.0
TYPICAL FIRE-STOPPING / PIPE PENETRATION
SCALE: 3"=1'-0"
RIGID STEEL PIPE (NO FLEX OR
PLASTIC)
NOTES:
DETAILS TO BE USED IN CONJUNCTION WITH STANDARD GUIDE
SPECIFICATIONS CONTAINING REQUIREMENTS FOR FIRE STOP SYSTEMS,
MATERIALS AND ACCESSORIES, ETC.
3M 'FIRE BARRIER SEALANT
CP-25WB+' FIRE STOP / SEALANT
SYSTEM, OR EQUIV. (TYP.)
FIRE RATED FLOOR ASSEMBLY
FIRE RATED WALL ASSEMBLY
ACOUSTIC INSULATION-
FULL HT. ALL WALLS
1
A6.0
TYPICAL NEW INTERIOR PARTITION
SCALE: 1"=1'-0"
NON-LOAD-BEARING WALL
SIMILAR TO CBC TABLE 7-B, ITEM 16.1.1 UL DES. U465
FLOORING -
SEE
FINISH
SCHEDULE
5" BASE W/ 3/8" DIA. COVE
INTEGRAL W/ FLR'G OR TOP
SET RUBBER BASE
-SEEFINISH SCHEDULE
EXIST. CONC. FLR. DECK
GYP. BD./T-BAR
CEILING SEE REFLECTED
CEILING PLAN
LINE OF CEILING
SUSPENSION SYST.
8'
-
0
"
3 5/8" X 25 GA. MTL.
STUD DIAG.
BRACING @ 48" O.C.
STAGGERED EA. SIDE
4"
+-
3
'
-
6
"
MA
X
.
EXIST. STRUCTURAL DECK
3 - #10 x 1" WOOD
SCREWS - SEE TOP CONN.
INSET ON 1A6.0
RAMSET SERIES 1500
0.145 DIA./1" EMBED.
SHOT PINS AT 16" O.C.
PER ICC ESR-1799
5/8" GYP. BD. EA. SIDE
OVER 3 5/8" X 25 GA. MTL.
STUDS AT 16" O.C. PER
ICC ESR-1538
DESIGN, INSTALLATION & CONSTRUCTION OF COLD FORMED STEEL LIGHT FRAMED CONSTRUCTION SHALL BE IN ACCORDANCE
WITH CBC 2210
ALL COLD FORMED STEEL LIGHT
FRAMED CONSTRUCTION &
MATERIALS SHALL BE PER ICC
ESR-1538
EXIST. WD. JOISTS -
PROVIDE BLOCKING
WHERE NECESSARY
3 - #10 x 1" WOOD
SCREWS @ ALL TOP
CONN.
TYP. TOP CONNECTION @ DIAGONAL BRACING
EXIST. 2X FRAMING -
PROVIDE BLOCKING
WHERE NECESSARY
3 - #10 x 1" WOOD
SCREWS @ ALL TOP
CONN.
TYP. TOP CONNECTION @ CEILING RUNNERS
NOTE: TOP CONNECTION CONDITIONS TO APPLY
TO ALL FRAMING DETAILS
SE
E
A
-
2
.
0
PROVIDE CONT. PLUG-IN LED TAPE
LIGHTING BY LEDI INSPIRE V4 NUDE
TAPE LIGHT - ALL COVES, TYP.
6"
3 #10 S.M.S. PER LAP
20 GA. X 3-5/8" MTL. STUD
AT 16" O.C.
SCREW TRACK TO VERT. STUD W/
2- #10 SMS AT 16" O.C.
TYP. HARD-LID CL'G:
" TYPE 'X' GYP. BD. ON 3-5/8" X 20 GA. MTL. STUD JOISTS AT 16" O.C. MAX. SPAN
11'-6" - FOR GREATER SPANS (UP TO 16'-0") ADD VERT. TIE TO STRUCTURE ABOVE -
ICC ESR-1538
TOP TRACK - ATTACH AT 24" O.C.
MAX W/2 #10 SCREWS, (TYP.) -
CONNECTIONS PER DETAIL 1A6.0
(TYP.)
3 5/8" X 20 GA. MTL. DIAG.
BRACING AT 48" O.C. MAX.
ATTACH TO STRUCT. SOFFIT
EXIST. U/S ROOF
STRUCT.
CEILING SYSTEM PER
CBC 2506.2.1 & ASCE 7-05
ICC ESR-1308
4
A6.0
COVE LIGHTING DETAIL
SCALE: 1-1/2"=1'-0"
6"
6"
CONNECTIONS PER
DETAIL 1A6.0 (TYP.)
SE
E
A
-
2
1'
-
0
"
SEE PLAN
3 #10 S.M.S. PER
LAP
20 GA. X 3-5/8" MTL. STUD
AT 16" O.C.
SCREW TRACK TO VERT. STUD W/ 2-
#10 SMS AT 16" O.C.
TYP. HARD-LID CL'G:
" TYPE 'X' GYP. BD. ON
3-5/8" X 20 GA. MTL.
STUD JOISTS AT 16" O.C.
MAX. SPAN 11'-6" - FOR
GREATER SPANS (UP TO
16'-0") ADD VERT. TIE TO
STRUCTURE ABOVE -
ICC ESR-1538
3 5/8" X 20 GA. MTL. DIAG.
BRACING AT 48" O.C. MAX.
ATTACH TO BLKG. ABOVE W/ 3 #10
S.M.S. PER CONN, TYP. ALL LOCNS.
20 GA. X 3-5/8" MTL.
STUD AT 16" O.C.
1'
-
0
"
1'
-
0
"
1'-0"
20 GA. X 3-5/8" MTL. STUD
AT 16" O.C.
2
A6.0
CEILING SOFFIT AT RECEPTION
SCALE: 1-1/2"=1'-0"
A-6.0
INTERIOR
DETAILS
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
SHEET NO.
2509
REVISIONS:
5/30/2025DATE:
PROJECT NO.
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
S
a
n
t
a
A
n
a
,
C
A
9
2
7
0
4
1
2"
DBL. STUDS
EA. SIDE
JAMB
3
8"
13
8"
6
A6.1
KNOCK DOWN DOOR FRAME
SCALE: 3"=1'-0"
HORIZONTAL
STIFFENER
5/8" TYPE X
GYP. BD.
EQUIP. SUPPORT
BRACKET - ATTACH
PER MANUF'S
DETAILS
WHERE REQ'D.
PROVIDE 16 GA.
SHEET MTL. BACKING
MTL. STUD FRAMING
@ 16" O.C.
8
A6.1
EQUIP. SUPPORT IN WALL
SCALE: 3"=1'-0"
CERAMIC TILE
WAINSCOT
THIN SETTING BED
5/8" WATER RESIST.
GYP. BD.MTL. STUD
@ 16" O.C.
5/8" WATER RESIST.
GYP. BD.
MARLITE WAINSCOT
CAULKING TYP.
SEAMLESS RESILIENT
FLOORING & COVE
BASE OVER CONC.
MTL. STUD
@ 16" O.C.
B
9
A
9
CERAMIC FLOOR
TILE ON THINSET
BED OVER CONC.
CERAMIC BASE
COVE TILE
9
A6.1
COVE BASE
SCALE: 3"=1'-0"
7
A6.1
FLOOR TRANSITION DETAIL
SCALE: N.T.S.
JOINT SEALANT TO
MATCH GROUT
TILE/VINYL/MASTIC
LEVELING
COMPOUND AS
REQD.
MECH. ATTACH
MTL. STRIP - SECURE
TO SUBFLOOR
METAL TRANSITION
STRIP AS REQD.
CARPET
FLOORING,
TYP.
CONC. SUBFLOOR -
GRIND/CHIP AS REQD.
TO ENSURE SMOOTH
INSTALL
NOTE: VINYL TO TILE TRANSITION SIMILIAR - FLOAT
FLOOR AS REQD. FOR SMOOTH TRANSITION
GYP. BD. ON MTL.
STUD
KNOCK-DOWN
MTL. DOOR FRAME
W/ MIN. 3 JAMB
ANCHORS PER
EDGE. ANNOD.
FIN. - "WESTERN
INTEGRATED" OR
EQUAL
1 3/4" THK. SOLID
CORE DOOR
5
A6.1
MECHANICAL DOOR FRAME
N.T.S.
13
8"
GYP. BD. ON MTL.
STUD
KNOCK-DOWN MTL. DOOR
FRAME W/ MIN. 3 JAMB
ANCHORS PER EDGE.
ANNOD. FIN. - "WESTERN
INTEGRATED" OR EQUAL
1 3/4" THK. SOLID
CORE DOOR
3
8"
1
2"
DBL. STUDS EA. SIDE
JAMB
SEALS: ZERO MOD.#
475A, OR EQ. ALL 4
SIDES
VERIFY HINGE SIZE AND
QUANTITY AND REINF.
JAMBS AT HINGES
SOUND ABSORPTION-LINED
JAMBS W/ INSULATION TO
ENSURE LIGHT SEAL
QUIETROCK GYP. BD.
OR EQUIV.
PAIRS OF 16 GA.
STEEL STUDS
@ 16" O.C. @
BACKING PLATE
PLAN - SECTION
BACKING PLATE
3
16" X 9"
11
2" STAINLESS STEEL
GRAB BAR
CONCEALED
MOUNTING PLATE
3-# 14 TEK SCREWS
BACKING PLATE 3
16" X 9"
ELEVATION 2'
-
9
"
T
O
F
I
N
.
F
L
R
MTL. STUD
FRAMING
@ 16" O.C.
GRAB BAR - ATTACH
PER MANUF'S
DETAILS
5/8" TYPE 'X' GYP.
BD.
HORIZONTAL
STIFFENER
11
A6.1
GRAB BAR SUPPORT IN WALL
SCALE: 3"=1'-0"
112"
3"
112"
3"
9"
MAINTAIN
112" CLR.
GRAB BARS SHALL MEET THE FOLLOWING
(CBC 11B-609):
1. BENDING STRESS, SHEAR STRESS, SHEAR FORCE,
AND TENSILE FORCE SHALL ALL BE LESS THAN MAX.
ALLOWED BY A 250LB. POINT LOAD. (CBC
11B-609.8)
2. GRAB BARS SHALL NOT ROTATE IN THEIR FITTINGS.
(CBC 11B-609.6)
NO BASE
F.F.
SEE PLAN FOR
CEILING HEIGHTS
12" TEMP. GLZ. W/
BEVELLED EDGES &
STRUCT. SILICONE
BTWN. PANES
5 8" ALUM. CHANNEL
W/ STRUCT.
SILICONE CAULK.
12
A6.1
INTERIOR GLASS WALL
SCALE: 1-1/2"=1'-0"
SEE 1A6.0 FOR TOP
CONNECTIONS
#10 S.M.S. @ 12" O/C
EA. WAY
RAMSET SERIES 1500 0.145
DIA./1" EMBED. SHOT PINS
AT 16" O.C. PER ICC
ESR-1799
NEW NO. 3 REINF. BAR
AT 18" O.C. EA. WAY TIE
INTO DOWELS -ENSURE
MIN. 2" CONC. COVER
NEW UTILITY TRENCH
INFILLED W/
COMPACTED GRAVEL
/ ROCK FILL
10
A6.1
SLAB REPAIR DETAIL
1 1/2"=1'-0"
NEW NO. 3 TO BE DOWELLED INTO
EDGE OF EXISTING SLAB AT 18"
O.C.
NEW
EXISTING
FLOOR
SLAB
EXIST.
REINF.
5"
V
.
I
.
F
.
EMBED
7" MIN.5" MIN.
4"
SAND
BED
4 MIL POLY
V.B.
SECURE DOWEL W/
SIMPSON SET-XP
EXPOXY - SPECAL
INSPECTION REQ.
DBL. STUDS
EA. SIDE
JAMB
3
8"
4
A6.1
FREMELESS DOOR FRAME
SCALE: 3"=1'-0"
GYP. BD. ON MTL.
STUD
EZYCONCEPTS EZY
JAMB SRC MTL.
DOOR FRAME
SYSTEM W/ #10
S.M.S. @ 8" O/C @
PERIM. - MUD/FIN.
TO EDGE OF
FRAME
1 3/4" THK. SOLID
CORE DOOR
INVISIBLE
MORTISED
HINGES PER
MANU.
SEALS: ZERO
MOD.# 475A,
OR EQ. ALL 4
SIDES
3
A6.1
POCKET DOOR FRAME
SCALE: 3"=1'-0"
INSTALL POCKET DOOR GLIDE
HDWR AND END STOP
BUMPERS
PRE-FAB 3/4" PAINTED
WOOD DOOR JAMBS
VERIFY POCKET SIZE AND
SLIDING HDWR.
WD. POCKET-DOOR
FRAME
1 3/4" THK. SOLID CORE FLUSH
DOOR (SEE DOOR SCHED.)
SNAP-ON BRUSHED
ALUM TRIM
5/8" TYPE 'X' GYP. BD. EA. SIDE
MTL. STUDS AT 16" O.C.
1/2"
1/
2
"
1
1
/
4
"
32" MINIMUM
PER CBC 1115B.4.1 &
CBC 1133B.2.2
POCKET DOOR TO BE HAFELE
FUTURA SERIES
PROVIDE BUMPER IN POCKET TO PREVENT
DOOR FROM FULLY RECEDING
PROVIDE DOOR PULLS- BOTH SIDES PER CBC
1133B.2.5.2 MOUNTED 44" MAXIMUM FROM FLOOR
PER CBC FIGURE 11B-33
POCKET (SLIDING) DOOR
HEADER - SEE STRUCT.
KAWNEER TRIFAB 400
STOREFRONT SYSTEM
SEALANT TYP.
HEAD
SILL
1
A6.1
STOREFRONT WINDOW SYSTEM DETAILS
SCALE: 3"=1'-0"
KAWNEER TRIFAB 400
STOREFRONT SYSTEM
SEALANT TYP.
WALL BEYOND
SIDEWALK THRESHOLD TO
BE FLUSH
TRANSOM
CONT. SEALANT
3 4" STUCCO ON GALV. EML
(FASTENER MAX. 12" O/C EA.
WAY) ON TYVEK WRAP ON 3 4"
PLY. ON 2X6 WD. STUD WALL @
16" O.C W/ R-21 BATT. INSUL. &
5 8" TYPE X GYP. BD. INTERIOR
SEALANT
TYP.
FACE OF FLOOR SLAB TYP.
HILTI 'X-U' SHOT PINS @
24" O.C. (ICC #2269)
11
4" EMBED.
#10 WOOD
SCREWS @
12" O.C.
2
A6.1
STOREFRONT DOOR DETAIL
SCALE: 3"=1'-0"
HEADER
CONT. SEALANT
SEALANT TYP.
THRESHOLD10" MIN.
SWEEP & DRIP
SLOPE AWAY MIN.
1/8" PER FOOT
1/4"
MAX. EA.
ALUM. THRESH. BAR SET
IN MASTIC AND
SCREWED TO SLAB
KAWNEER TRIFAB 400
STOREFRONT SYSTEM
DOOR HEAD
HILTI 'X-U' SHOT PINS @
24" O.C. (ICC #2269)
11
4" EMBED.
#10 WOOD SCREW
@ 12" O.C.
3 4" STUCCO ON GALV. EML
(FASTENER MAX. 12" O/C EA.
WAY) ON TYVEK WRAP ON 3 4"
PLY. ON 2X6 WD. STUD WALL @
16" O.C W/ R-21 BATT. INSUL. &
5 8" TYPE X GYP. BD. INTERIOR
13
A6.1
FULL HT. CHART CABINET DETAIL
SCALE: 3"=1'-0"
CHART CABINETS TO
BE FLUSH OVERLAY
3/4" PLYWOOD
CONSTRUCTION WITH
PLASTIC LAM. FINISH
(TYP.)
SHELF, TYP.
ALL H.P. PLASTIC
LAM. INTERIORS AND
EXTERIORS
12" PLASTIC LAM.
FACED BASE
CABINET PULL
PROVIDE FULL HT. 12"
DIVIDERS @ 4 12" O.C.
- SEE ELEVATION
SCRIBE TO CEILING
BLOCKING AS
NECESSARY
NOTE: COORDINATE WITH INTERIOR
ELEVATIONS ON A3.0
14
A6.1
SLIDING GLASS DOOR DETAIL
N.T.S.
43
4"
311
16"
43
4"
17
8"
INTERIOR EXTERIOR
3
4"
INTERIOR EXTERIOR
1 3
16"9
16"
1 7
16"
31
8"
11
16"11
16"1 1
16"5
16"
CRL4932EXT
CRL4932EXT
#10 S.M.S. @ 12" O/C
EA. WAY
3 8" OR 12" TEMPERED
GLASS
CRL 6979A
CRL 2940
14" FASTENER
SUSPENDED DRYWALL
CEILING
A-6.1
INTERIOR
DETAILS
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
SHEET NO.
2509
REVISIONS:
5/30/2025DATE:
PROJECT NO.
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
S
a
n
t
a
A
n
a
,
C
A
9
2
7
0
4
31
"
27
"
M
I
N
.
C
L
E
A
R
SEE PLAN
ACCESSIBLE
COUNTER
COUNTERTOP PER FIN. SCHED.
1A-6.2
BASE SEE FINISH SCHEDULE
5/8" PLY ON WD. STUD
SHOP-BUILT WD. FRAME -
COORD. W/ ELEC.
EXTERIOR SURFACES PER
FIN. SCHED.
12"
8"
33
"
42
"
3"
SEE PLAN
HUTCH W/ DIVIDERS AT MAX 24"
O.C.
1A-6.2
SUPERBRIGHT LED LIGHTING AT
TOE-KICK - BLK. AS REQ.
BASE SEE FINISH SCHEDULE
COUNTERTOP FINISH
PER FIN. SCHEDULE
PROVIDE CONT. LED TAPE
LIGHTING AT TRANS. TOP
1/2" REVEAL
5/8" PLY ON WD. STUD SHOP-BUILT
WD. FRAME - COORD. W/ ELEC.
EXTERIOR SURFACES PER FIN. SCHED.
8
A6.2
RECEPTION COUNTER
SCALE: 1-1/2"=1'-0"
TRANSACTION
COUNTER
31
"
27
"
M
I
N
.
C
L
E
A
R
CUSTOM CABINETS -
SEE A-3.0
VENT PIPE SUPPLIED
& INSTALLED BY PLUMBING
SUB-CONTRACTOR
1'
-
6
"
PLUMBING PIPE SUPPLIED &
INSTALLED BY PLUMBING
SUB-CONTRACTOR
DRAIN AND SINK
CONNECTS BY
PLUMBING
SUB-CONTRACTOR
BASE/TRIM
34
"
3
A6.2
CUSTOM CABINET SINK PLUMBING
1"=1'-0"
PROVIDE BACKING IN
WALL AS REQ'D. (TYP.)
VENT CONDITION IN
CEILING PLENUM BY
PLUMBING
SUB-CONTRACTOR
14W T-8 FLUOR TASK
LIGHTING: "ALKO SUPER
INCH" (CONT. TYP.)
3'
-
0
"
1
A6.2
CANTILEVERED COUNTER BRACKET
SCALE: NTS
18"
SECURE TO TOP W/SCREWS
16"
MTL. STUD WALL
MITER CORNER & WELD
1 1/2" X 1 1/2" X 1/8" ANGLE BRACKET
SECURE TO STUD WALL
PLYWOOD TOP AND BACKSPLASH
4"MIN. RADIUS
NO SEAM
PLASTIC LAMINATE OVER 3/4"
FACE OF CABINET
WHERE OCCURS
24" TYP."
GYP. BD. /
PROVIDE BRACKETS AT 24" O.C. WHERE
NO OTHER SUPPORTS (TYP.)
GYP. BD.
ON MTL.
STUD
3" BRUSHED ALUM. WIRE
PULLS (TYP.)
2'-1"
BLK'G AS
REQ'D.
4"
SE
E
E
L
E
V
.
SE
E
E
L
E
V
.
PLASTIC LAM. ON 3/4"
PLYWOOD DECK
PLYWOOD DRAWER W/
100 LBS FULL EXTN.
DRAWER GLIDES
INTERIOR SHELVES TO BE
3/4" MELAMINE FIN. OR
PLAS. LAM. AT SINKS.
INSTALL ON CLIP ANGLES
BASE - SEE FINISH SCHED. /
SHEET A-3.0
BACKSPLASH
CABINET CASES TO BE
FLUSH OVERLAY 3/4"
PLYWOOD
CONSTRUCTION, OR AS
NOTED IN SPECS, WITH
PLASTIC LAM. FINISH (TYP.)
SOFFIT WHERE OCCURS -
SEE PLAN
2
A6.2
TYPICAL CABINET DETAIL
SCALE: 3"=1'-0"
CONT. PLAS. LAM. SCRIBE
PANEL
5
A6.2
FULL HT. WALL DETAIL
SCALE: 3"=1'-0"
PROVIDE 1
LAYER
IMPACT
RESISTANT 5/8"
TYPE 'X' GYP. BD.
BOTH SIDES
20 GA. MTL. STUD
@ 16"o.c.
2 1
2"
5
8" MIN./ 3
4" MAX.
R-13 INSULATION
(ACOUSTIC)
WALL: UL U465
BOTTOM WALL: UL BW-S-0007
HEAD WALL: HW-D-0134
THROUGH PENETRATIONS: UL W-L-2580
ICC ESR-1042
LINE OF EXIST.
ROOF STRUCTURE
NO. 8 x 916"
WAFERHEAD
SCREW, TYP. 2
BOTTOM OF
STRUCTURE
EQ.2 #10 WD. SCREWS @
16"O/C
SLP-TRK SLOTTED
TRACK-MIN. 20
GA, 3 5 8" WIDE,
MIN. 2 12" LEGS
EQ.
LINE OF CONC.
FLOOR
EQ.
2 - #10 x 1" WOOD
SCREWS @ 16"O.C.
PER ICC ESR-1799, TYP.
EQ.
1/4"Ø X 3" LONG
(TYP. OF 4)
LAG SCREW
PER DETAIL BELOW (TYP).
SECURE HEATER TO WALL
GALV. SPILL PAN
+
+
HW~
~
CW
+
-
UNION, TYP.
WH
+
S.O.V., TYP.
SECTION
SPRING.
1/4" THREADED
7
A6.2
WATER HEATER BRACING
SCALE: NTS
WHERE PROVIDED,
SECURE EXPN. TANK
TO SOLID BACKING
WH
WALL
ELEV.INSET DETAIL
SEE INSET DETAIL
3/4"Ø SPILL PRESSURE
TEMPERATURE RELIEF
VALVE TO EXTERIOR PER
CPC SECTION 608.4.
NOTE:
PROVIDE WATER HEATER, SIZED PER CPC SECTION 501.0
WATER HEATER SHALL BE STRAPPED TO THE WALL IN TWO PLACES. ONE IN THE UPPER 1/3 AND ONE IN THE LOWER 1/3 OF THE TANK. THE LOWER POINT SHALL BE A MIN. OF
4" ABOVE THE CONTROLS, ALL PER CPC SECTION 507.2.
1/4"Ø THREADED
ROD W/U-BOLT
1/2" MIN.
3'
-
0
"
F.F.
3 5/8" X 16 GA.
MTL. DIAG.
BRACING IF REQ'D.
1" CDX
PLYWOOD TOP
COORD.
INSTALLATION OF
AQUARIUM -
SUPPLIED BY OWNER
PLATIC LAMINATE
FACED BASE
3/4" X 2" WOOD
FIN. TRIM TOP
PLASTIC LAM.
FACED CAB.
DOORS
PLAS. LAM FINISHED
3/4" PLYWOOD
SUB-CASE AND
BOTTOM SHELF
TANK SIZE/TYPE
TBD BY OWNER
6
A6.2
AQUARIUM SUPPORT DETAIL
SCALE: 1-1/2"=1'-0"
3 5/8" X 16 GA.
MTL.
STUD FRAMING
AT 16" O.C.
A
Q
U
A
R
I
U
M
B
Y
O
W
N
E
R
A-6.2
INTERIOR
DETAILS
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
SHEET NO.
2509
REVISIONS:
5/30/2025DATE:
PROJECT NO.
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
S
a
n
t
a
A
n
a
,
C
A
9
2
7
0
4
1:3:6 MIXTURE OF
DRY CONC. PACKED
4" ALL AROUND
MIN. 6" AGGREGATE
BASE ALL AROUNDASPHALT SURFACING ON
CRUSHED ROCK BASE
PREPARED
SUB-GRADE
6"
FIN. GRADE
6"
6
A6.3
CONCRETE CURB DETAIL
SCALE: 1"=1'-0"
CAST-IN-PLACE OR
PRECAST CONCRETE CURB
W/ 1/2" MORTAR JOINTS
10
"
1'-0"
CONTROL JOINTS TO FORM RECT.
OR SQ. W/ MAX. SPACING OF
12'-0" - PER SOILS REPORT
5" THICK CONC. SLAB W/#4 BARS @
18" O/C EA. WAY @ MID-DEPTH
10
A6.3
EXPANSION JOINT / CONTROL JOINT (TYP.)
SCALE: 1"=1'-0"
COMPACTED EARTH
REINF. CONC. SLAB
CONTROL JOINT
W/ SEALANT
4" DEEP SAND BASE W/
10 MIL. POLY LINER MID-DEPTH -
LAP 6" MIN. @ SEAMS
11
A6.3
CONCRETE FLATWORK
SCALE: 1"=1'-0"
(2) #4 REBAR TOP
AND BOTTOM
REINF. CONC. SLAB
EXPANSION JOINT
W/ COMP. FILLER
AND SEALANT
1
2" MAX.
FLUSH
3
A6.3
EXTERIOR WALL @ STUCCO
SCALE: 3"=1'-0"
CONC. FLOOR SLAB ON V.B.
INTERIOREXTERIOR
2x6 WD. STUDS @ 16" O/C (PER
STRUCT.) W/ R-21 BATT. INSUL.
& 5
8" TYPE X GYP. BD. INT.
15
32" I STRUCT PLY. - ALIGN
W/ EDGE OF SLAB
A.B. PER STRUCT.
3 4" STUCCO ON GALV. EML
(FASTENER MAX. 12" O/C EA.
WAY)(W/ DRAIN CHNL.) ON
TYVEK WRAP
3 4" STUCCO ON GALV.
EML (FASTENER MAX. 12"
O/C EA. WAY) ON TYVEK
WRAP ON 3 4" PLY. ON 2X6
WD. STUD WALL @ 16"
O.C W/ R-21 BATT. INSUL.
& 5 8" TYPE X GYP. BD.
INTERIOR
ALUM. CAP W/ KYNAR FIN.
SLOPED @ 14" / FT. ATTACH
W/ CEMENT ADHESIVE
ALUM. COUNTER
FLASHING BTWN COPING
AND CROWN CAP
2
A6.3
PARAPET CAP DETAIL
SCALE: 3"=1'-0"
SNAP-LOCK ALUM.
PARAPET COPING
(CAP) W/ KYNAR FIN.
2X10 CONT. WOOD
NAILER ATTACHED TO
WD. STUD WALL W/
3/8" X 4" LAG BOLTS
AT 48" O.C. MAX.
ATTACH ROOFING
MATERIAL TO NAILER
W/ FLAT HEAD SCREW
AND NEOPRENE
WASHER MAX. 24"
O.C.
WEATHERWELD
MEMBRANE ROOFING
TO EXTEND OVER TOP
OF WALL - FASTEN PER
MANU. INSTRUCTIONS
3"
6"
5
A6.3
EAVE ISOMETRIC
1 1/2" = 1'-0"
CONTINUOUS CLEAT SET IN
BUTYL TAPE FASTEN 8" ON CENTER
UNDERLAYMENT
EAVE FLASHING
PANEL
TRIPLE BEAD
BUTYL TAPE
LOWER PANEL
6" LAP MIN.
9-15 HEX HEAD
WOODZAC FASTEN
THROUGH BUTYL 4"
ON CENTER
CB 2000
UPPER PANEL
DOUBLE BEAD
BUTYL TAPE
4
A6.3
PANEL LAP ISOMETRIC
1 1/2" = 1'-0"
1
A6.3
IPE WOOD SIDING
SCALE: 3"=1'-0"
EXTERIOR
1 X 6 TONGUE AND GROOVE
IPE SIDING ON GALV. EML
(FASTENER MAX. 12" O/C EA.
WAY) ON TYVEK WRAP ON 3 4"
PLY.
A-6.3
EXTERIOR
DETAILS
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
SHEET NO.
2509
REVISIONS:
5/30/2025DATE:
PROJECT NO.
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
S
a
n
t
a
A
n
a
,
C
A
9
2
7
0
4
A PLANCHECK
REVISIONS 10-15-25
1. WALL MOUNTED SIGNAGE TO BE LOCATED ON THE LATCH SIDE OF DOOR CLEAR OF DOOR SWING. MOUNT
@ 48" MIN. TO THE BASELINE OF THE LOWEST LINE OF BRAILLE CELLS TO 60" MAX. A.F.F. TO THE BASELINE OF THE HIGHEST
LINE OF RAISED TEXT. .
2. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED
ON THE NEAREST ADJACENT WALL, PREFERRABLY AT THE RIGHT.
3. SIGNS MUST NOT BE INSTALLED BEHIND OBSTRUCTIONS AND READER MUST BE ABLE TO APPROACH SIGN WITHIN 3"
WITHOUT BEING HIT BY SWING OF DOOR
4. SIGN COLOR MUST CONTRAST AT 70% MIN. W/ BACKGROUNDS (DOOR OR WALL)
5. FOR LOCATION AND MOUNTING SEE A1.0 & A4.0
PLAN
CLEAR FLOOR SPACE
ELEVATION
MIRROR
34
"
M
A
X
.
TO
S
I
N
K
R
I
M
27
"
M
I
N
.
CL
R
.
19" MIN.
LINE OF FACE OF
CABINET BEYOND
INSULATE PIPES
25"
MAX.
FRONT APRON OF
COUNTER CABINET 6
1
/
2
"
SINK
1/4" MAX
ALLOWABLE
CLOSURE PRESSURE:
THRESHOLDS:
1. CHARACTER TYPE: CHARACTERS ON SIGNS SHALL BE RAISED 132" (0.794MM) MIN. AND SHALL BE HELVETICA MEDIUM
UPPERCASE CHARACTERS ACCOMPANIED BY GRADE 2 BRAILLE.
2. CHARACTER SIZE: RAISED CHARACTERS SHALL BE A MINIMUM OF 5 8" (15.9MM) AND A MAXIMUM OF 2" (51MM) HIGH.
3. FINISH AND CONTRAST: CONTRAST BETWEEN CHARACTERS, SYMBOLS AND THEIR BACKGROUND MUST BE 70%
MINIMUM AND HAVE A NON-GLARE FINISH. CBC 11B-703.5.1
4.PROPORTION: CHARACTERS ON SIGNS SHALL HAVE A WIDTH-TO-HEIGHT RATIO OF BETWEEN 1:5 AND 1:10. CBC
11B-703.2
ALL LETTER MEASURED MUST BE UPPERCASE. AFTER CHOOSING A TYPE TO TEST, BEGIN BY PRINTING THE LETTERS I, X, AND
0 AT 1" HIGH. PLACE A 1:1 SQUARE OVER THE X OR 0, WHICHEVER IS NARROWER, IF THE CHARACTER IS NOT WIDER THAN
1", NOR NARROWER THAN A 3:5 RECTANGLE, THE PROPORTIONS ARE CORRECT. USE A 1:5 RECTANGLE TO DETERMINE
OF THE STROKE OF THE I IS TOO BROAD, AND THE 1:10 RECTANGLE TO SEE IF IT IS TOO NARROW. IF THE TESTS ARE PASSED,
THE TYPE STYLE IS COMPLIANT WITH PROPORTION CODE.
1. ACCESSIBLE BUILDING ENTRANCES ARE REQUIRED TO BE IDENTIFIED WITH AT LEAST ONE STANDARD SIGN AND
ADDITIONAL DIRECTIONAL SIGNS AS REQUIRED TO BE VISIBLE TO PERSONS ALONG APPROACHING PEDESTRIAN WAYS.
2. PROVIDE SIGNS WITH INTERNATIONAL SYMBOL OF ACCESSIBILITY INDICATING LOCATION OF EACH ACCESSIBLE ENTRY
PROVIDE ADDITIONAL DIRECTIONAL SIGNS AS REQUIRED.
3. LETTERS AND NUMBERS ON SIGNS SHALL HAVE A WIDTH TO HEIGHT RATIO BETWEEN 3:5 AND 1:1 AND A STROKE WIDTH
TO HEIGHT RATIO BETWEEN 1:5 AND 1:10.
4. CHARACTERS AND NUMBERS ON SIGNS SHALL BE SIZED ACCORDING TO THE VIEWING DISTANCE FROM WHICH THEY
ARE TO BE READ, APPLICABLE TO OVERHEAD SIGNS
5. LETTERS AND NUMERALS SHALL BE RAISED 1/32", UPPER CASE, SANS SERIF OR SIMPLE SERIF TYPE AND SHALL BE
ACCOMPANIED WITH GRADE 2 BRAILLE. RAISED CHARACTERS SHALL BE AT LEAST 5/8" (16MM) HIGH, BUT NO HIGHER
THAN PICTOGRAMS SHALL BE ACCOMPANIED BY THE EQUIVALENT VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE
PICTOGRAM. THE BORDER DIMENSION OF THE PICTOGRAM SHALL BE 6" (152MM) MINIMUM IN HEIGHT.
6. THE CHARACTERS AND BACKGROUND OF SIGNS SHALL BE EGGSHELL, MATTE, OR OTHER NON-GLARE FINISH.
CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND - EITHER LIGHT CHARACTERS ON A DARK
BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND.
7. WHERE PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES, SIGNS SHALL BE INSTALLED ON THE WALL
ADJACENT TO THE LATCH SIDE OF THE DOOR. WHERE THERE IS NO WALL SPACE TO THE LATCH SIDE OF THE DOOR,
INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL. MOUNTING HEIGHT
SHALL BE 48" MIN. TO THE BASELINE OF THE LOWEST LINE OF BRAILLE CELLS TO 60" MAX. A.F.F. TO THE BASELINE OF THE
HIGHEST LINE OF RAISED TEXT. MOUNTING LOCATION FOR SUCH SIGNAGE SHALL BE SO THAT A PERSON MAY APPROACH
WITHIN 3" (76 MM) OF SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A
DOOR.
36
"
36"
7
A7.0
SCALE: 3/4"=1'-0"
(TYP.) THE SURFACE OF EACH PARKING
SPACE FOR THE DISABLED IS REQUIRED TO
HAVE A 3 FOOT SQUARE "INTERNATIONAL
SYMBOL OF ACCESSIBILITY". THE
ACCESSIBILITY SYMBOL SHALL BE A STENCILED
WHITE FIGURE ON BLUE BACKGROUND
(COLOR #15090, FEDERAL STANDARD 595C).
FIGURE TO MATCH PROPORTIONS OF FIGURE
11B-703.7.2.1
10
A7.0
ACCESSIBLE IDENTITY SIGNAGE
SCALE: NTS
1. ALL DOORWAYS TO HAVE 32" CLEAR ACCESS MINIMUM.
2. UNINTERRUPTED SPACE AT BOTTOM OF DOOR TO BE 10" EXCEPT
FOR AUTOMATIC DOORS.
3. NO REVOLVING DOOR ALLOWED FOR ACESSIBLE DOORS.
4. THRESHOLD MAX. HT.=1/2" WITH MAX. VERT. CHANGE OF 1/4".
5. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5
POUNDS FOR EXTERIOR DOORS, 5 POUNDS FOR INTERIOR DOORS,
AND 15 POUNDS FOR FIRE DOORS WITH DSA APPROVAL.
INTERIOR DOORS = 5 POUNDS
EXTERIOR DOORS = 5 POUNDS
FIRE DOORS = 15 POUNDS
COMPRESSED CARPET 1/4" MAX.
BELOW THRESHOLD
FINISH FLOOR LEVEL
THRESHOLD
1/2"MAX. AT
1:2 SLOPE
2'-10" TO 3'-8" A.F.F.
PUSH-PULLLEVER
DOOR/HANDLE
CLEARANCE
1
2" MAX.
FOR LATCHING DOORS
1. OPERABLE FROM A SINGLE EFFORT, NO
GRASPING OR WRIST MOVEMENT(LEVERS,
PUSH-PULL OR PANIC DEVICES).
2. MOUNTED AT 34"-44" HIGH. PER 11B-404.2.7
3. OPENABLE FROM INSIDE WITHOUT USE OF
KEY, SPECIAL KNOWLEDGE OR EFFORT.
1/2"MAX.
1/4"MAX.
DOOR NOTES
HARDWARE NOTES
2
A7.0
GENERAL STANDARDS FOR DOORS
SCALE: NTS
1. ACCESSIBLE SPACE MUST PERMIT USE OF EITHER OF THE CAR DOORS.
2. BUMPERS REQUIRED WHEN NO CURB OR BARRIER IS PROVIDED WHICH WILL PREVENT ENCROACHMENT OF CARS
OVER WALKWAYS.
3. WHEELCHAIR USERS MUST NOT BE FORCED TO GO BEHIND PARKED CARS OTHER THAN THEIR OWN.
4. WHEN ONLY ONE SPACE IS PROVIDED IT HAS TO BE 17 FT. WIDE TO PROVIDE A 9 FT. PARKING AREA AND A 8 FT.
LOADING AND UNLOADING AREA.
5. WHEN MORE THAN 1 SPACE IS REQUIRED, 2 SPACES CAN BE PROVIDED WITHIN A 26' WIDE AREA
6. EACH PARKING SPACE IS REQUIREDTO BE AT LEAST 18' LONG.
7. SURFACE SLOPES OF PARKING AREAS FOR THE DISABLED SHOULD BE MINIMAL, BUT ARE REQUIRED NOT TO EXCEED
1/4" PER FOOT SLOPE IN ANY DIRECTION.
8. RAMPS SHALL NOT ENCROACH INTO ANY PARKING SPACE.
9. ACCESSIBLE SPACE SHALL BE NEAR ACCESSIBLE PRIMARY ENTRANCE OF BUILDING.
10. ONE VAN ACCESSIBLE PARKING SPACE IS REQUIRED FOR EVERY 6 REQUIRED ACCESSIBLE SPACES WITH THE FIRST
REQUIRED ACCESSIBLE SPACE BEING VAN ACCESSIBLE. CBC 11B-208.2.4
11. PROVIDE 114" MINIMUM VERTICLE CLEARANCE FOR VAN AND 98" FOR CAR PARKING AREAS.
12. LOADING ZONE SPACES SHALL HAVE A MINIMUM OF 9'-6" VERTICAL CLEARANCE.
13. NON-PARKING PASSENGER LOADING ZONES SHALL PROVIDE AN ACCESS AISLE AT LEAST 60" WIDE AND 20' LONG
ADJACENT AND PARALLEL TO THE VEHICLE PULL-UP SPACE. IF THERE ARE CURBS BETWEEN THE ACCESS AISLE ANE THE
VEHICLE PULL-UP SPACE, THEN A CURB RAMP SHALL BE PROVIDED.
14. EACH PARKING SPACE REQUIRED FOR THE DISABLED SHALL BE IDENTIFIED BY A SIGN. THE SIGN SHALL INCLUDE THE
INTERNATIONAL SYMBOL OF ACCESSIBILITY. THE PARKING LOT SHALL HAVE A SIGN NOT LESS THAN 18" X 24" IN SIZE WITH
LETTERING NOT LESS THAN 1" HEIGHT.
15. THE WORDS "NO PARKING" SHALL BE PAINTED ON THE GROUND WITHIN EACH 5 FOOT LOADING/UNLOADING
ACCESS AISLE. THIS NOTICE SHALL BE PAINTED IN WHITE LETTERS NO LESS THAN 12" HIGH AND LOCATED SO THAT IT IS
VISIBLE TO TRAFFIC ENFORCEMENT OFFICIALS.
16. THE ACCESS AISLE SHALL BE MARKED BY A BORDER THAT IS PAINTED BLUE. WITHIN THAT BLUE BORDER, HATCHED
LINES SHALL BE A MAX. 36" O/C & SHALL BE PAINTED WITH A COLOR THAT CONTRASTS W/ THE PARKING SURFACE,
PREFERABLY BLUE OR WHITE.
PARKING NOTES
3
A7.0
GENERAL STANDARDS FOR ACCESSIBLE PARKING STALLS
SCALE: NTS
NEW ACCESSIBLE PARKING
SIGN TYP. 70" SQ. ON POLE
WALK 5'-0" MIN. OPTIONAL
18
'
-
0
"
M
I
N
.
9'-0" MIN.
SINGLE CAR
DOUBLE CAR
5'-0" (CARS)
8'-0" (VANS)
9'-0" MIN.
3'-0" ON CENTER, TYP.
TYPICAL SYMBOL
36" SQUARE PER
7A7.0
TACTILE SIGNAGE NOTES
GENERAL SIGNAGE NOTES
NOTES
SINK NOTES
1. WHERE REQUIRED TO BE ACCESSIBLE,
PROVIDE A CLEAR SPACE 30"x48" IN FRONT
OF SINK. THE CLEAR SPACE MAY EXTEND
INTO KNEE AND TOE SPACE UNDER LAV.
2. INSULATE OR COVER ALL WATER AND
DRAIN PIPES UNDER SINK.
3. NO SHARP ABRASIVE SURFACES ARE
ALLOWED UNDER SINK.
4. FAUCET CONTROLS AND OPERATING
MECHANISMS ARE REQUIRED TO BE
OPERABLE WITH ONE HAND AND CANNOT
REQUIRE GRASPING, PINCHING, OR
TWISTING OF WRIST. THE FORCE REQUIRED
TO ACTIVATE CONTROLS IS NOT TO EXCEED
5 lbf. LEVER OPERATED, PUSH TYPE AND
ELECTRONICALLY CONTROLLED
MECHANISMS ARE EXAMPLES OF
ACCEPTABLE DESIGN.
5. SINK SHALL BE MAX 6 1/2" DEEP
6. SINK RIM MOUNTED MAX 34" AFF. KNEE
SPACE 27" HIGH BY 19" DEEP BY 30" WIDE
REQ'D.
7. KNEE AND TOE CLEARANCE PER CBC
11B-306
4
A7.0
GENERAL STANDARDS FOR SINKS
SCALE: NTS
1. PROVIDE A CLEAR SPACE 30"x48" IN FRONT OF LAV. THE CLEAR SPACE MAY EXTEND INTO KNEE AND TOE SPACE UNDER LAV.
2. INSULATE OR COVER ALL WATER AND DRAIN PIPES UNDER LAVATORIES.
3. NO SHARP ABRASIVE SURFACES ARE ALLOWED UNDER LAVATORIES.
4. FAUCET CONTROLS AND OPERATING MECHANISMS ARE REQUIRED TO BE OPERABLE WITH ONE HAND AND CANNOT REQUIRE GRASPING,
PINCHING, OR TWISTING OF WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS IS NOT TO EXCEED 5 lbf. LEVER OPERATED, PUSH TYPE AND
ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGN.
6. SELF CLOSING VALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS.
7. IF A MIN. 9" HEIGHT OF TO CLEARANCE IS PROVIDED, A MAX. OF 6" OF THE 48" OF CLEAR FLOOR SPACE REQUIRED AT THE FIXTURE MAY
EXTEND INTO THE TOE SPACE.
LAVATORY NOTES
8
A7.0
GENERAL STANDARDS FOR LAVATORIES
SCALE: 3/4"=1'-0"
BRACE
TO
WALL
INSULATE HOT & COLD WATER AND DRAIN PIPES
11
A7.0
DOME PAVER DETAIL
SCALE: 1-1/2"=1'-0"
INTERNATIONAL SYMBOL
OF ACCESSIBILITY
9"
MI
N
.
27
"
M
I
N
.
29
"
M
I
N
.
34
"
M
A
X
.
40
"
M
A
X
.
6"
MAX.
8"
MIN.
17" MIN.
17" MIN.
18
"
M
I
N
.
TO
C
/
L
30
"
M
I
N
.
19" MAX.
48" MIN.2.3" TO 2.4"
APART 0.45" TO 0.47" AT TOP
0.9" TO 0.92" AT BTM.
0.
2
"
H
T
TAPERED EDGES
WHERE EXPOSED
PROVIDE 12" X 12" CONTRASTING COLOR QUARRY-TILE
PRODUCT AS 'TERRAPAVER' MANUF. WAUSAU TILE CO.
(715) 359-3121
DETECTABLE WARNINGS SHALL
COMPLY WITH CBC 11B-705.1.
ONLY DSA-AC DETECTABLE
WARNING PRODUCTS ARE INSTALLED.
2.3" TO 2.4"
APART
CL CL CL
TILE JOINT
CONTRAST COLOR (PER CBC 11B-705.1.1.3):
YELLOW PER FS 33538
1
2
2.
3
5
"
CL CL
CL CL
3"3"
3"
3"
8" MIN.
11" MIN.
19" MIN.
9"
M
I
N
.
NO PARKING
MIN. 0.65" BASE SPACING
GRAB BAR
40
"
M
A
X
.
1 1/2"1 1/2"
1 1/4"
TO
1. LOCATE GRAB BARS ON EACH SIDE OR ON ONE SIDE AND IN BACK OF TOILET, 33" TO 36" ABOVE AND
PARALLEL TO FLOOR TO TOP OF GRIPPING SURFACE. BARS AT SIDE TO BE 42" LONG. BARS IN BACK TO BE MIN.
36" LONG.
2. DIAMETER OR WIDTH OF GRIPPING SURFACE IS REQUIRED TO BE TO 1 1/2" OR SHAPE IS TO PROVIDE AN
EQUIVALENT GRIPPING SURFACE.
IF GRAB BARS ARE MOUNTED ADJACENT TO WALL, THE SPACE BETWEEN WALL AND BAR IS TO BE 1 1/2".
3. GRAB BARS SHALL NOT ROTATE IN THEIR FITTINGS.
4. GRAB BARS AND MOUNTINGS SHALL WITHSTAND 250 LBS. POINT LOAD.
1. WHERE TOWEL, SANITARY NAPKIN AND WASTE RECEPTACLES AND SIMILAR
DISPENSING AND DISPOSAL FIXTURES ARE PROVIDED, AT LEAST ONE OF EACH TYPE IS
TO BE LOCATED WITH ALL OPERABLE PARTS, INCLUDING COIN SLOTS, WITHIN 40" FROM
THE FLOOR.
2. MOUNT MIRRORS WITH BOTTOM OF REFLECTIVE SURFACE EDGE NO MORE THAN 40"
FROM FLOOR.
3. LOCATE TOILET TISSUE DISPENSERS ON WALL 7" TO 9" FROM FRONT EDGE OF TOILET
SEAT AND 19" MIN. AFF.
TOILET ACCESSORIES
GRAB BARS
ACCESSIBILITY COMPLIANCE NOTES
1
A7.0
GENERAL STANDARDS FOR TOILET ACCESSORIES
SCALE: NTS
TOILET
33" TO 36"
TO TOP OF
GRIPPING
SURFACE
CL
3'-0"
1'-0"2'-0"
1. ACCESSIBLE SIGNAGE PER CBC 11B-703 & 11B-604.8.2.2 SHALL BE PROVIDED AT TOILET FACILITIES. SIGNS TO HAVE
RAISED LETTERS PLUS BRAILLE, AND ARE TO BE INSTALLED 48" MIN. AFF OR GROUND SURFACE, MEASURED FROM THE
BASELINE OF THE LOWEST BRAILLE CELLS AND 60" MAX. AFF OR GROUND SURFACE, MEASURED FROM THE BASELINE OF
THE HIGHEST LINE OF RAISED CHARACTERS. SIGN SHALL BE LOCATED ADJACENT TO LATCH SIDE OF DOOR.
2. ALL DOORS SHALL COMPLY WITH CBC 1007, 1010, 11B-206.5, AND 11B-404, AS APPLICABLE. DOOR HARDWARE
SHALL BE LEVER OR PUSH TYPE, MOUNTED 34" TO 44" ABOVE THE FLOOR, PER CBC 11B-404.2.7. ALL DOORS SHALL BE
3'-0" WIDE, PER CBC 11B-404.2.3.
3. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR
INTERIOR DOORS. SUCH PUSH OR PULL EFFORT SHALL BE APPLIED AT RIGHT ANGLES TO HINGED DOORS. AT REQUIRED
FIRE DOORS, MAX. OPERATING EFFORT MAY BE INCREASED TO 15 LBS.
4. PER CBC 11B-302 & 11B-404.2.5, REGARDLESS OF THE OCCUPANT LOAD, THERE SHALL BE A LEVEL FLOOR OR
LANDING ON EACH SIDE OF THE DOOR. THE FLOOR OR LANDING SHALL NOT BE MORE THAN 1/2" LOWER THAN THE
THRESHOLD OR THE DOORWAY.
5. THE LOWER 10" OF ALL DOORS SHALL BE SMOOTH AND UNINTERRUPTED TO ALLOW THE DOOR TO BE OPENED BY A
WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION.
6. TELEPHONES SHALL BE HEARING AID COMPATIBLE WITH VOLUME CONTROLS CAPABLE OF MIN. 12 DBA / MAX 18 DBA
ABOVE NORMAL. PROVIDE PUSH-BUTTON CONTROLS AND MIN. 29" CORD TO HANDSET.
7. SINKS AND LAVATORIES SHALL COMPLY WITH ADA SEC. 4.19 AND THE FOLLOWING:
a) A MINIMUM OF 30" x 48" CLEAR SPACE SHALL BE PROVIDED IN FRONT OF THE LAVATORY .
b) THE CLEAR SPACE BENEATH LAVATORIES SHALL BE A MINIMUM OF 29" HIGH x 30" WIDE x 8" DEEP AT THE TOP
AND 9" HIGH x 30" WIDE x 17" DEEP AT THE BOTTOM. THE MAXIMUM HEIGHT OF THE BASIN / COUNTER TOP SHALL
BE 34" HEIGHT MAX.
c) ALL WATER AND DRAIN PIPES UNDER THE LAVATORY SHALL BE INSULATED.
d) FAUCET CONTROLS SHALL HAVE AN OPERATING FORCE OF NOT GREATER THAN 5 POUNDS.
8. ALL FLOORS TO BE SLIP-RESISTANT.
PLAN
48
"
MI
N
.
ELEVATION
24
"
MI
N
18"
MIN.
17"-
18"
1. SUFFICIENT SPACE IS REQUIRED IN TOILET ROOM FOR A WHEELCHAIR MEASURING 30" WIDE BY 48" LONG TO ENTER ROOM AND PERMIT DOOR
TO CLOSE.
2. WHEN THE DOOR IS LOCATED IN CORRIDOR SIDEWALL AND SWINGS INTO CORRIDOR, MIN. WIDTH OF CORRIDOR SHALL BE 60" UNLESS OTHER
STATE OR LOCAL BUILDING CODES ALLOW LESSER CORRIDOR WIDTH.
3. ALL TOILETS TO HAVE FLUSH HANDLES ON WHEELCHAIR ACCESS SIDE (INCLUDING TANK TOILETS)
4. FLUSH CONTROL SHALL BE AN OSILLATING HANDLE WITH MAX. 3 lbf. OPERATING FORCE, ELECTRIC OPERATION OR APPROVED EQUAL.
5. TOILET TISSUE DISPENSERS SHALL BE LOCATED ON THE WALL 7" TO 9" FROM THE FRONT EDGE OF THE TOILET SEAT, AND HAVE CONTINUOUS
PAPER FLOW.
6. FORWARD APPROACH - MANEUVERING CLEARANCE SHALL BE PROVIDED FOR ALCOVE, MIN. 36" WIDE WHERE DEPTH EXCEEDS 24". - PER CBC
11B-305.7.1
TOILET NOTES
PRIVACY LOCK DOOR
32" MIN. CLEAR
FLUSH CONTROL LOCATED ON
WIDE SIDE OF TOILET MAX 44" AFF
36" MIN. GRAB BAR
42" MIN GRAB BAR
ROLL PAPER HOLDER
60"CL.
5
A7.0
ACCESSIBLE SINGLE OCC. TOILET
SCALE: 3/4"=1'-0"
42" MIN.
GRAB BAR12" MAX.
33
"
(3
6
"
I
F
T
A
N
K
OB
S
T
R
U
C
T
S
)
17
"
-
1
9
"
7"-9"
54" MIN.
60"
MIN.
19
"
MI
N
.
56
"
M
I
N
.
MATERIALPRODUCTTRADENAMEMODELNUMBER
6
A7.0
ACCESSIBLE PARKING AUTHORIZATION SIGN
SCALE: 3/4"=1'-0"
9
A7.0
ACCESSIBLE PARKING STALL SIGN
SCALE: 3/4"=1'-0"
36
"
36
"
NOTE:
SIGNS SHALL BE PORCELAIN
ON STEEL W/ REFLECTORIZED
BEADED TEXT.12"
12"
NOTE:
SIGNS SHALL BE PORCELAIN ON STEEL
W/ REFLECTORIZED BEADED TEXT.
VAN ACCESSIBLE SIGN
WHITE SYMBOL &
LETTERING ON
BLUE BACKGROUND
H/C PARKING SIGN
2X2 STL. OR ALUM.
TUBE PRIME AND PAINT
2 COATS FLAT BLACK
FINE SIGNAGE
2-1/4" DIA. STANLESS
SELF-TAPPING
SCREWS OR BOLTS
AT EACH SIGN,TYP.
80
"
MIN. SIGN
AREA 70 SQ.
INCHES
18
"
FINISH GRADE
GALV. STL. TUBE
SLEEVE
ACCESSIBLE
VAN
MINIMUM
FINE $250
12
"
3"
12"
1" HIGH LETTERING W/ THE
FOLLOWING MESSAGE:
UNAUTHORIZED VEHICLES PARKED
IN DESIGNATED ACCESSIBLE
SPACES NOT DISPLAYING
DISTINGUISHING PLACARDS OR
SPECIAL LICENSE PLATES ISSUED FOR
PERSONS WITH DISABILITIES
WILL BE TOWED AWAY AT OWNER'S
EXPENSE. TOWED VEHICLES MAY
BE RECLAIMED BY TELEPHONING
THE POLICE DEPARTMENT:
(714) 245-8665
17"
3"
GALV. STL. TUBE
SLEEVE
2X3 STL. OR ALUM.
TUBE PRIME AND PAINT
2 COATS FLAT BLACK
22
"
12
"
80
"
6"
FINISH GRADE
CORROSPONDING
GRADE II BRAILLE
SHALL BE LOCATED
DIRECTLY UNDER
LETTER OR SYMBOL
INFO.
HT. OF LETTERING
5 8" MIN. TO 2" MAX.
UPPERCASE LETTERS
MEN
DOOR SIGNAGE, TYP.WALL SIGNAGE, TYP.
60
"
M
A
X
.
12"
12"
2"
TACTILE SIGN
RESTROOM DOOR
SIGN SET AT 58"-60"
SELF-LUMINOUS EXIT
SIGN, SEE ELEC.
EXIT
12"
3
8"
8"
EXIT
14" THICK
8"
ACCESSIBLE
ROUTE
14" THICK
48
"
M
I
N
.
60
"
M
A
X
.
48
"
M
I
N
.
MENWOMEN
9"9"
MEN WOMEN
12"
12"
MEN
14" THICK
WOMEN
14" THICK
12"
3
8"
8"
6"
T
Y
P
.
10
"
MEN
14" THICK
WOMEN
14" THICK
MAXIMUM
OCCUPANCY
14" THICK
###
MAXIMUM
OCCUPANCY
8"ASSISTIVE
LISTENING
SYSTEMS
AVAILABLE
ASSISTIVE LISTENING
SYSTEMS
14" THICK
12"12"
ALL-GENDER
14" THICK
DOOR THRESHOLDS TO COMPLY WITH CBC 1010.1.7
58
"
-
6
0
"
#5 REBAR 18" LONG
PLAN
2 #3 REBAR
EPOXY TO PAVING
9"
4'-0"
12
A7.0
CONCRETE WHEEL STOP
SCALE: 1"=1'-0"
ELVATION
512"
SECTION
7"
2"
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
SHEET NO.
2509
REVISIONS:
5/30/2025DATE:
PROJECT NO.
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
S
a
n
t
a
A
n
a
,
C
A
9
2
7
0
4
A-7.0
ACCESSIBILITY
DETAILS
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
110
SPRNKLR.
101
RECEPTION
100
WAITING
107
OFFICE
109
PVT. OP
111
WORK AREA
113
PVT.OP
116
OP
117
OP
114
OP
115
OP
110
PVT.OP
106
STORAGE
103
ALL GENDER
RESTROOM
119
STERILIZATION/
LAB
120
OFFICE
104
CONSULTATION
105
CONSULTATION
121
MECHANICAL
103
PANO
102
ALL GENDER
RESTROOM
112
HALLWAY
118
OP
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
110
SPRNKLR.
101
RECEPTION
100
WAITING
107
OFFICE
109
PVT. OP
111
WORK AREA
113
PVT.OP
116
OP
117
OP
114
OP
115
OP
110
PVT.OP
106
STORAGE
103
ALL GENDER
RESTROOM
119
STERILIZATION/
LAB
120
OFFICE
104
CONSULTATION
105
CONSULTATION
121
MECHANICAL
WH
MOP
103
PANO
118
OP
102
ALL GENDER
RESTROOM
WASHER
DRYER
108
HALLWAY
112
HALLWAY
+42"
GFI
+42"
GFI
GFI
J
TV+8
0
"
J
AIR VAC
AIR
VAC
+42"
GFI
+42"
+42"
+42"
+42"+42"
+42"
+42"
GFI
+42"
+42"
+42"
GFI
+60"
MICRO
+42"+42"
GFI
+42"
GFI
+42"
TV
+80"
USB-C
USB-C
USB-C
+42"
+42"
+42"
+42"
+42"
+42"
+42"
+42"
+42"
+42"
+42"
+42"
+42"
+42"
+42"
+42"
+42"
+42"+42"
+42"
TV
+80"
TV
+80"
TV
+80"
TV
+80"
TV
+80"
TV
+80"
TV
+80"
+42"
+42"
+42"+42"+42"+42"+42"
+42"
UL
T
R
A
S
O
N
I
C
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
110
SPRNKLR.
101
RECEPTION
100
WAITING
107
OFFICE
109
PVT. OP
111
WORK AREA
113
PVT.OP
116
OP
117
OP
114
OP
115
OP
110
PVT.OP
106
STORAGE
103
ALL GENDER
RESTROOM
119
STERILIZATION/
LAB
120
OFFICE
104
CONSULTATION
105
CONSULTATION
121
MECHANICAL
WH
MOP
103
PANO
118
OP
102
ALL GENDER
RESTROOM
WASHER
DRYER
108
HALLWAY
112
HALLWAY
AIR VAC
AIR
VAC
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
110
SPRNKLR.
101
RECEPTION
100
WAITING
107
OFFICE
109
PVT. OP
111
WORK AREA
113
PVT.OP
116
OP
117
OP
114
OP
115
OP
110
PVT.OP
106
STORAGE
103
ALL GENDER
RESTROOM
119
STERILIZATION/
LAB
120
OFFICE
104
CONSULTATION
105
CONSULTATION
121
MECHANICAL
WH
MOP
103
PANO
118
OP
102
ALL GENDER
RESTROOM
WASHER
DRYER
108
HALLWAY
112
HALLWAY
AIR VAC
AIR
VAC
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
110
SPRNKLR.
101
RECEPTION
100
WAITING
107
OFFICE
109
PVT. OP
111
WORK AREA
113
PVT.OP
116
OP
117
OP
114
OP
115
OP
110
PVT.OP
106
STORAGE
103
ALL GENDER
RESTROOM
119
STERILIZATION/
LAB
120
OFFICE
104
CONSULTATION
105
CONSULTATION
121
MECHANICAL
WH
MOP
103
PANO
118
OP
102
ALL GENDER
RESTROOM
WASHER
DRYER
108
HALLWAY
112
HALLWAY
AIR VAC
AIR
VAC
Plumbing Notes:
Plumbing Keynotes
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
SHEET NO.
REVISIONS:
DATE:
PROJECT NO.2509
5/30/2025
Dr
.
K
a
l
a
n
t
a
r
i
D
e
n
t
a
l
O
f
f
i
c
e
DE
N
T
A
L
O
F
F
I
C
E
T
E
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
P
R
O
J
E
C
T
22
2
2
S
.
B
r
i
s
t
o
l
S
t
r
e
e
t
,
S
u
i
t
e
A
,
B
,
C
,
D
,
C
o
s
t
a
M
e
s
a
,
C
A
9
2
6
2
6
SANTA ANA CITY COUNCIL
Mayor
vamezcua@santa-ana.org
Mayor Pro Tem - Ward 2
bvazquez@santa-ana.org
Ward 1
tphan@santa-ana.org
Ward 3
jessielopez@santa-ana.org
Ward 4
pbacerra@santa-ana.org
Ward 5
jryanhernandez@santa-ana.org
Ward 6
dpenaloza@santa-ana.org
MAYOR
Valerie Amezcua
MAYOR PRO TEM
Benjamin Vazquez
COUNCILMEMBERS
Phil Bacerra
Johnathan Ryan Hernandez
Jessie Lopez
David Penaloza
Thai Viet Phan
CITY OF SANTA ANA
PLANNING AND BUILDING AGENCY
20 Civic Center Plaza ● P.O. Box 1988
Santa Ana, California 92702
www.santa-ana.org
CITY MANAGER
Alvaro Nuñez
CITY ATTORNEY
Sonia R. Carvalho
CITY CLERK
Jennifer L. Hall
August 21, 2025
Also sent via email to: jared@architectsoc.com
Jared Dudley
Saunders + Wiant Architects
2700 West Coast Highway Suite 200
Newport Beach, CA, 92663
Subject: Address Assignment for a proposed tenant improvement located at 2222 S. Bristol
Street, Unit A and (APN: 408-471-18) in Santa Ana, CA
Dear Jared,
The City of Santa Ana Planning and Building Agency (PBA) is the responsible agency for legal
addressing within the City of Santa Ana’s jurisdiction. This letter confirms the address assignment
for the unit combination of Unit A and Unit B for the tenant improvement project for Dr. Kalantari
Dental Office located at 2222 S. Bristol Street and (APN: 408-471-18). Notice is hereby given that
the following assigned address(es) shall be posted onsite per the approved address plan,
attached hereto as Exhibit A.
Address to be Deactivated/Removed
To subdivide commercial and/or residential units into multiple units, a building permit (and all other
associated permits), plans, and inspection approvals by the PBA are required. Address(es) will
be verified during inspections by the Building Safety Division.
Please update your records accordingly. Should you have any questions, feel free to contact me
by phone at (714) 667-2719 or by email at AChu@santa-ana.org.
Sincerely,
Aaron Chu
Planning Technician
Address Letter for 2222 S. Bristol Street, Unit A
Page 3 of 3
c:
Kris K Chu, Santa Ana Manager, United States Post Office
Fernando Banuelos, Fountain Valley Manager, United States Post Office
Yesenia Torres, Santa Ana Manager, United States Post Office
Enrique Ponce, Sna-North Grand Sta Manager, United States Post Office
Esthephany Treto Ramirez, Admin Supervisor, United States Post Office
Chris Tuiolosega, United States Post Office
Alex Alvarez, Santa Ana Postmaster, United States Post Office
Federal Express, Administration
Cathy Joseph, Garden Grove Unified School District
Christine Hy, Garden Grove Unified School District
Cathy Slader, Orange Unified School District
Ted Walstrom, Santa Ana Unified School District
Jeremy Cogan, Santa Ana Unified School District
Yvette Miranda, Santa Ana Unified School District
Cristina Bernal, Tustin Unified School District
Orange County Fire Authority
Neal Kelly, Registrar of Voters
Members, Board of Supervisors
Southern California Gas Company
Southern California Edison Company
Claude Parrish, County Assessor's Office
GIS
SAG, AT&T
UPS, Administration
City Manager’s Office
Beverly Martin, Police Community Services Specialist
Boris Duran, Police Systems Manager
Jennifer Arellano, Police Communications Manager
Chris Hubbard, Police Systems Support Analyst
Alejandra Gutierrez, Treasury & Customer Services Manager
Hector Jimenez, Revenue Supervisor
Alfonso Chavez, Utilities Customer Services Supervisor
Judson Brown, Housing Division Manager
Rudy Rosas, Deputy Public Works Director / City Engineer
Zdenek (Zed) Kekula, Principal Civil Engineer
Jason Kwak, Building Safety Manager
Evelyn LaRocca, Permit Services Principal
Kathy Hernandez, Permit Technician
Julie Amsden, Permit Technician
Ricardo Soto, Acting Planning Manager
Jerry Guevara, Senior Planner
Yvette Portugal, Code Enforcement Manager
Jerry Navarro, Code Enforcement Principal
Address Letter for 2222 S. Bristol Street, Unit A
Page 3 of 3
Exhibit A – Address Plan
YES NO
INSTRUCTIONS:
ORAN GE COUNTY FI RE AUTHORI TY
Plan Submittal Criteria
COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects
and RESIDENTIAL TRACT developments
· Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place.
· Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section.
· If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA.
· In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations.
· Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding
requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602.
Address Suite City
Project Scope/Business Description
1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways,
curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within
300 feet of an active or proposed oil well? Fire Master Plan (PR145)
2. Property is adjacent to a wildland area or non-irrigated native vegetation?
Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124)
3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from
an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170)
4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving
private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475)
5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000
sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable
to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless
classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration
or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses
where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories
with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285)
6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card,
button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan
depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520)
7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment;
industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible
liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium
ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations?
Special Equipment Plan (PR315, PR340-PR382)
8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft
maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if
H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240)
9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard
commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330)
10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a
commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335)
Initial each of the following two items indicating that you have read and understand the statement:
11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is
required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed
Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications.
12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located
in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327—
Initials the building department will determine specific requirements.
I certify under penalty of perjury under the laws of the State of California that the above is true:
Print Name Signature
Phone Number ( ) Date / /
Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA
review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the
applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the
appropriate plans and fees for OCFA review. 10-08-14 EE
COM
O R A N G E C O U N T Y F I R E A U T H O R I T Y
Plan Referral Form
Required for OCFA to review plans upon the request of the Building Department when
the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”.
City / County Official Requesting Review:
City / County Reference #: Date: __________________________________
City / County: _____________________________________ E-Mail: __________________________________
Contact Name: _____________________________________ Phone #: _________________________________
Title: _____________________________________
** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. **
Reason(s) for Review:
Please describe why OCFA Plan Review is or may be required by the City/County :
OCFA COMMENTS:
No further action required on this specific plan type, based
on information provided on: ____/______/______.
Project to be taken in for OCFA Review.
Other:
Name: _________________________________________
Contact #: ______________________________________ Date: _________________________________
OCFA Authorization
Updated: 06/02/2020 rs
CITY OF SANTA ANA
PUBLIC WORKS AGENCY
20 Civic Center Plaza • M-22
Santa Ana, California 92702
www.santa-ana.org
(714)647-5659
CITY OF SANTA ANA
Planning and Building Agency
Approved
FOR PERMIT ISSUANCE
Master
Date:
WATER QUALITY MANAGEMENT PLAN (WQMP) CHECKLIST
Proj ect Title and Address: Dr Ka /g 0-Frn If I. _.Pm4o / (7-t% re d-_O -S • BA6401 S-6 A
Select the type of construction that applies to your parking lot project then follow the arrows to determine if the
project is subject to WQMP requirements. Submit the completed checklist to the Public Works Agency.
Construction of a Addition or Redevelopment to
new parking lot an existing parkin! lot
Enter surface area
(square -feet) of new
parking lot, including
drive aisles, exposed to
stormwater runoff in
Box 1 below.
Does the project result in the
addition of new impervious surface'
to the existing parking lot area
(i.e. increased parking area)?
Yes j JIL No
Enter surface area (square -feet) of
parking lot addition, including
drive aisles, exposed to stormwater
runoff in Box 2 below.
sq-ft I Yes
Does the project consist of a "grind
and overlay" and/or "slurry seal"
treatment to the existing parking
lot surface?
l 7sq-ft No WQMP ■
Required'
'Impervious surface is a surface that prohibits stormwater infiltration into the ground Checkbox
00
'Native soil is the soil below any existing engineered fill or base material
'Project is considered routine maintenance
No
If the sum of the values entered into Box 1, 2, and 3 is greater than or equal to 5,000 r
square -feet, the project is subject to WQMP requirements and will require a grading
permit. Public Works Agency — Development Engineering staff review and approve No WQMP ❑
WQMPs and grading plans. Grading permits may also be required for routine Required'
maintenance projects, subject to the discretion of the Public Works Agency. Checkbox
1 certify that the above information is true and accurate to the best of my knowledge. ) am aware that City
staff may conduct inspections of the project during construction and if staff determine the project is in fact
subject to WQMP requirements, a Stop Work Order and/or Administrative Citation(s) with Administrative
Fine(s) may be issued t e contractor and property owner, and a WQMP will be required for the project.
Signature Print Name: 794 j2,k,s JZ Date:�5
No
Is native soil' being
exposed, surface
material changing (i.e.
asphalt to concrete), or
grade/drainage patterns
changing?
i Yes
Enter surface area
(square -feet) of
redeveloped parking lot,
including drive aisles,
exposed to stormwater
runoff in Box 3 below.
3
sq-ft
May 2022 Page 2 of 2