Loading...
HomeMy WebLinkAbout2120 & 2120 3%4 S Bristol St #WCC01 - Plan YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs CIT,YOF SANTA ANA Planning and Building Agency SITE PHOTO Ld e 0 a PROJECT INFORMATION iJ SITE NAME: EDINGER AND BRISTOL rn COUNTY: ORANGE bi ADDRESS: 2120 1/2 SOUTH BRISTOL V) SANTA ANA, CA 92704 UJ JURISDICTION: CITY OF SANTA ANA CURRENT ZONING: C2 — GENERAL COMMERCIAL N SITE #: SICA001875 w g w FA #: 10087160 PTN 3551A117849 3 IWM #: WSLOS0068563 z LATITUDE: N 33' 43' 8.44" (33.719) UJ LONGITUDE: W 117 53' 12.8" (-117.8869167) 0 iW GROUND ELEVATION: 48' AMSL PARCEL ID: 408-471-17 TOWER OWNER: CROWN CASTLE 0 200 SPECTRUM CENTER DR, SUITE 1700 N & 1800 IRVINE, CA 92618 a CROWN CASTLE BU# 845391 PROPERTY OWNER: AU ZONE SANTA ANA LLC 24025 PARK SORRENTO, STE 300 CALABASAS, CA m APPLICANT: AT&T 1452 EDINGER AVENUE, 3RD FLOOR TURN, CA 92780 o PROJECT CONSULTANTS to U W PROJECT MANAGEMENT: M o SITE ACQUISITION: 0 z ARCHITECT: 0 H CONSTRUCTION: o RF MANAGER: 0 U- 0 N SITE ACQUISITION MANAGER: U) z z 0 I CIVIL MANAGER: z Z 0 0 z 0 M A&E MANAGER: 0 z AMENTUM AMENTUM BC ARCHITECTS ENGINEERS, PLC AMENTLIM AT&T MUHAMMAD UMAIR MU31980ATT.COM AMENTUM REBECCA KAPONO 2600 MICHELSON DR #500 IRVINE, CA 92612 AMENTUM MIKE PHILLIPS 2600 MICHELSON DR #500 IRVINE, CA 92612 AMENTUM HAROLD NANK00 2600 MICHELSON DR #500 IRVINE, CA 92612 AT&T PROJECT: SG NR 1SR ANTENNA DOD ADD SITE FA PTN In JURISDICTION. SITE NAME: SICA001 875 10087160 3551A117849 WSLOS0068563 CITY OF SANTA ANA EDINGER AND BRISTOL ADDRESS: 2120 1/2 SOUTH BRISTOL SANTA ANA, CA 92704 VICINITY MAP Brea Chino Hills V -4- State Park ■ z Fullerton Cerrttos s Anaheim 57 241 e+ 2 ' Garden Gro e est Inster 261 4ntatn 65 n ,\ -(2 i Lake Forest R, �t,4.^vjport NOT TO SCALE LOCAL MAP W St Gertrude PI 7 Q SITE >9 Mission Viejo II 1 Allso Vie i.aguna Beach NORTH NOT TO SCALE DRIVING DIRECTIONS DIRECTIONS FROM: 1452 EDINGER AVENUE 3RD FLOOR TUSTIN, CA 92780 ..... ........ .......... . W St Gertr Goodwill of Orange County Q Thrift store Know what's bylaw. Call before you dig. FOR MORE INFORMATION CONTACT THE STATE CORPORATION COMMISSION DIVISION OF UTILITY AND RAILROAD SAFETY SOUTHERN CALIFORNIA UTILITY PROTECTION SERVICE, INC. CALL BEFORE YOU DIG: 800-422-4133 11 .:T, 5691111 U► T-1 TITLE SHEET SP-1 NOTES & SPECIFICATIONS A-0 SITE PLAN A-1 COMPOUND PLAN A-1.1 PROPOSED EQUIPMENT PLAN A-1.2 GROUND EQUIPMENT DETAIL A-2 EXISTING & PROPOSED SOUTH TOWER ELEVATION A-2.1 EXISTING & PROPOSED WEST TOWER ELEVATION A-3 EXISTING & PROPOSED ANTENNA PLAN A-4 EXISTING & PROPOSED ANTENNA SCHEDULE A-5 TOWER EQUIPMENT DETAILS E-1 GROUNDING NOTES P-1 PLUMBING DIAGRAM (ALPHA SECTOR) P-1.1 PLUMBING DIAGRAM (BETA SECTOR) P-1.2 PLUMBING DIAGRAM (GAMMA SECTOR) THIS IS NOT AN ALL INCLUSIVE LIST. CONTRACTOR SHALL UTILIZE SPECIFIED EQUIPMENT PART OR ENGINEER APPROVED EQUIVALENT. CONTRACTOR SHALL VERIFY ALL NEEDED EQUIPMENT TO PROVIDE A FUNCTIONAL SITE. THE PROJECT GENERALLY CONSISTS OF THE FOLLOWING: TOWER SOW: 1. REPLACE POS 2 MAST PIPES W/ 2-7/8" (1) PER SECTOR 2. INSTALL (3) AIR6419 B77G ANTENNAS STACKED ABOVE THE (E) AIR6449 B77D ON POS A2,B2,C2 GROUND SOW: 1. INSTALL (1) -48V RECTIFIER IN THE DC POWER PLANT CODE COMPLIANCE • CALIFORNIA BUILDING CODE 2022, CBC 2022 AMENDED • CALIFORNIA ELECTRICAL CODE 2022, CEC 2022 AMENDED • CALIFORNIA MECHANICAL CODE 2022, CMC 2022 AMENDED REFERENCE MATERIALS THESE DRAWINGS ARE BASED ON AT&T RFDS DATED 11 05 2024 • REVISED RFDS PENDING. CONTRACTOR TO USE LATEST VERSION WITH CD'S PER SCOPE OF WORK. SPECIAL NOTES • ALL WORK SHALL BE INSTALLED IN CONFORMANCE WITH CURRENT AT&T CONSTRUCTION INSTALLATION GUIDE. EXISTING CONDITIONS WILL BE CHANGED & VERIFIED IN FIELD. IF SIGNIFICANT DEVIATIONS OR DETERIORATION ARE ENCOUNTERED AT THE TIME OF CONSTRUCTION, A REPAIR PERMIT WILL BE OBTAINED & CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY. • THESE DRAWINGS ARE FULL SIZE & SCALEABLE ON 11 "X17" SHEET SIZE. • STATEMENT THAT COMPLIANCE WITH THE ENERGY CODE IS NOT REQUIRED. —SCOPE OF WORK DOES NOT INVOLVE MODIFICATIONS TO EXTERIOR ENVELOPE OF BUILDING, HVAC SYSTEMS OR ELECTRICAL LIGHTING. DO NOT SCALE DRAWINGS CONTRACTOR SHALL VERIFY ALL PLANS & EXISTING DIMENSIONS & CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ARCHITECT OR ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. Approved Re AT&T t ; 1452 EDINGER AVENUE, 3RD FLOOR TUSTIN, CA 92780 amentum 2 ASH STREET, ST #3000 CONSHOHOCKEN, PA 19428 -13C a r c h i t e c t s e n g i n e e r s 5661 COLUMBIA PIKE, SUITE 200 FALLS CHURCH, VA 22041-2868 TEL (703) 671-6000 FAX: (703) 671-6300 REVISIONS REV. DATE DESCRIPTION INMALS A 01-23-25 ISSUED FOR REVIEW CG B 04-22-25 ISSUED FOR REVIEW SD 0 08-14-25 FINAL CD'S SD 1 09-05-25 FINAL CD'S SD 2 09-23-25 FINAL CD'S SD NOT FOR CONSTRUCTION UNLESS LABELED AS FOR CONSTRUCTION NSI0NgI J X * C 90957 ,k s� 923.ZS �Q 9� CIVIC (3� F pF C A��F LICENSE NUMBER: C90957 EXPIRATION DATE: MARCH 31, 2026 SICA001875 10087160 2120 1/2 SOUTH BRISTOL SANTA ANA, CA 92704 SHEET TITLE TITLE SHEET SHEET NUMBER T-1 E CITOF SANTA ANA Planning and Building Agency GENERAL CONSTRUCTION 1. FOR THE PURPOSE OF CONSTRUCTION DRAWINGS, THE FOLLOWING DEFINITIONS SHALL APPLY: CONTRACTOR/CM - AMENTUM SUB -CONTRACTOR - PER TRADE OWNER - AT&T WIRELESS 2. ALL SITE WORK SHALL BE COMPLETED AS INDICATED ON THE DRAWINGS AND AT&T PROJECT SPECIFICATIONS. 3. GENERAL CONTRACTOR SHALL VISIT THE SITE AND SHALL FAMILIARIZE HIMSELF WITH ALL CONDITIONS AFFECTING THE PROPOSED WORK AND SHALL MAKE PROVISIONS. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH ALL CONTRACT DOCUMENTS, FIELD CONDITIONS, DIMENSIONS, AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. 4. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. GENERAL CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF WORK. 5. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES, AND APPLICABLE REGULATIONS. 6. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 7. PLANS ARE NOT TO BE SCALED. THESE PLANS ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY UNLESS OTHERWISE NOTED. DIMENSIONS SHOWN ARE TO FINISH SURFACES UNLESS OTHERWISE NOTED. SPACING BETWEEN EQUIPMENT IS THE MINIMUM REQUIRED CLEARANCE. THEREFORE, IT IS CRITICAL TO FIELD VERIFY DIMENSIONS, SHOULD THERE BE ANY QUESTIONS REGARDING THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK. DETAILS ARE INTENDED TO SHOW DESIGN INTENT. MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF WORK AND PREPARED BY THE ENGINEER PRIOR TO PROCEEDING WITH WORK. 8. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 9. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION SPACE FOR APPROVAL BY THE ENGINEER PRIOR TO PROCEEDING. 10. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF WORK AREA, ADJACENT AREAS AND BUILDING OCCUPANTS THAT ARE LIKELY TO BE AFFECTED BY THE WORK UNDER THIS CONTRACT. WORK SHALL CONFIRM TO ALL OSHA REQUIREMENTS AND THE LOCAL JURISDICTION. 11. GENERAL CONTRACTOR SHALL COORDINATE WORK AND SCHEDULE WORK ACTIVITIES WITH OTHER DISCIPLINES. 12. ERECTION SHALL BE DONE IN A WORKMANLIKE MANNER BY COMPETENT EXPERIENCED WORKMAN IN ACCORDANCE WITH APPLICABLE CODES AND THE BEST ACCEPTED PRACTICE. ALL MEMBERS SHALL BE LAID PLUMB AND TRUE AS INDICATED ON THE DRAWINGS. 13. SEAL PENETRATIONS THROUGH FIRE RATED AREAS WITH UL LISTED MATERIALS APPROVED BY LOCAL JURISDICTION. CONTRACTOR SHALL KEEP AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DEBRIS. 14. WORK PREVIOUSLY COMPLETED IS REPRESENTED BY LIGHT SHADED LINES AND NOTES. THE SCOPE OF WORK FOR THIS PROJECT IS REPRESENTED BY DARK SHADED LINES AND NOTES. CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR OF ANY EXISTING CONDITIONS THAT DEVIATE FROM THE DRAWINGS PRIOR TO BEGINNING CONSTRUCTION. 15. CONTRACTOR SHALL PROVIDE WRITTEN NOTICE TO THE CONSTRUCTION MANAGER 48 HOURS PRIOR TO COMMENCEMENT OF WORK. 16. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF THE OWNER. 17. THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. 18. GENERAL CONTRACTOR SHALL COORDINATE AND MAINTAIN ACCESS FOR ALL TRADES AND CONTRACTORS TO THE SITE AND/OR BUILDING. 19. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SECURITY OF THE SITE FOR THE DURATION OF CONSTRUCTION UNTIL JOB COMPLETION. 20. THE GENERAL CONTRACTOR SHALL MAINTAIN IN GOOD CONDITION ONE COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA, AND CHANGE ORDERS ON THE PREMISES AT ALL TIMES. 21. THE GENERAL CONTRACTOR SHALL PROVIDE PORTABLE FIRE EXTINGUISHERS WITH A RATING OF NOT LESS THAN 2-A OT 2-A:10-B:C AND SHALL BE WITHIN 25 FEET OF TRAVEL DISTANCE TO ALL PORTIONS OF WHERE THE WORK IS BEING COMPLETED DURING CONSTRUCTION. 22. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES SHALL BE PROTECTED AT ALL TIMES, AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY THE ENGINEER. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS SHALL INCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION, B) CONFINED SPACE, C) ELECTRICAL SAFETY, AND D) TRENCHING & EXCAVATION. 23. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED, CAPPED, PLUGGED OR OTHERWISE DISCONNECTED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, AS DIRECTED BY THE RESPONSIBLE ENGINEER, AND SUBJECT TO THE APPROVAL OF THE OWNER AND/OR LOCAL UTILITIES. 24. THE AREAS OF THE OWNER'S PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION. 25. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO THE EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE FEDERAL AND LOCAL JURISDICTION FOR EROSION AND SEDIMENT CONTROL. 26. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUNDING. FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. 27. THE SUBGRADE SHALL BE BROUGHT TO A SMOOTH UNIFORM GRADE AND COMPACTED TO 95 PERCENT STANDARD PROCTOR DENSITY UNDER PAVEMENT AND STRUCTURES AND 80 PERCENT STANDARD PROCTOR DENSITY IN OPEN SPACE. ALL TRENCHES IN PUBLIC RIGHT OF WAY SHALL BE BACKFILLED WITH FLOWABLE FILL OR OTHER MATERIAL PRE -APPROVED BY THE LOCAL JURISDICTION. 28. ALL NECESSARY RUBBISH, STUMPS, DEBRIS, STICKS, STONES, AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF IN A LAWFUL MANNER. 29. ALL BROCHURES, OPERATING AND MAINTENANCE MANUALS, CATALOGS, SHOP DRAWINGS, AND OTHER DOCUMENTS SHALL BE TURNED OVER TO THE GENERAL CONTRACTOR AT COMPLETION OF CONSTRUCTION AND PRIOR TO PAYMENT. 30. CONTRACTOR SHALL SUBMIT A COMPLETE SET OF AS -BUILT REDLINES TO THE GENERAL CONTRACTOR UPON COMPLETION OF PROJECT AND PRIOR TO FINAL PAYMENT. 31. CONTRACTOR SHALL LEAVE PREMISES IN A CLEAN CONDITION. 32. THE PROPOSED FACILITY WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SEWER SERVICE, AND IS NOT FOR HUMAN HABITAT (NO HANDICAP ACCESS REQUIRED). 33. OCCUPANCY IS LIMITED TO PERIODIC MAINTENANCE AND INSPECTION, APPROXIMATELY 2 TIMES PER MONTH, BY AT&T TECHNICIANS. 34. NO OUTDOOR STORAGE OR SOLID WASTE CONTAINERS ARE PROPOSED. 35. ALL MATERIAL SHALL BE FURNISHED AND WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST REVISION AT&T MOBILITY GROUNDING STANDARD "TECHNICAL SPECIFICATION FOR CONSTRUCTION OF GSM/GPRS WIRELESS SITES" AND "TECHNICAL SPECIFICATION FOR FACILITY GROUNDING IN CASE OF A CONFLICT BETWEEN THE CONSTRUCTION SPECIFICATION AND THE DRAWINGS, THE DRAWINGS SHALL GOVERN. 36. CONTRACTORS SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS REQUIRED FOR CONSTRUCTION. IF CONTRACTOR CANNOT OBTAIN A PERMIT, THEY MUST NOTIFY THE GENERAL CONTRACTOR IMMEDIATELY. 37. CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY BASIS. 38. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM SITE VISITS AND/OR DRAWINGS PROVIDED BY THE SITE OWNER. CONTRACTORS SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. 39. NO WHITE STROBE LIGHTS ARE PERMITTED. LIGHTING IF REQUIRED, WILL MEET FAA STANDARDS AND REQUIREMENTS. ANTENNA MOUNTING 40. DESIGN AND CONSTRUCTION OF ANTENNA SUPPORTS SHALL CONFORM TO CURRENT ANSI/TIA-222 OR APPLICABLE LOCAL CODES. 41. ALL STEEL MATERIALS SHALL BE GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH ASTM A123 "ZINC (HOT -DIP GALVANIZED) COATINGS ON IRON AND STEEL PRODUCTS", UNLESS NOTED OTHERWISE. 42. ALL BOLTS, ANCHORS AND MISCELLANEOUS HARDWARE SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A153 "ZINC -COATING (HOT -DIP) ON IRON AND STEEL HARDWARE", UNLESS NOTED OTHERWISE. 43. DAMAGED GALVANIZED SURFACES SHALL BE REPAIRED BY COLD GALVANIZING IN ACCORDANCE WITH ASTM A780. 44. ALL ANTENNA MOUNTS SHALL BE INSTALLED WITH LOCK NUTS, DOUBLE NUTS AND SHALL BE TORQUED TO MANUFACTURER'S RECOMMENDATIONS. 45. CONTRACTOR SHALL INSTALL ANTENNA PER MANUFACTURER'S RECOMMENDATION FOR INSTALLATION AND GROUNDING. 46. ALL UNUSED PORTS ON ANY ANTENNAS SHALL BE TERMINATED WITH A 50-OHM LOAD TO ENSURE ANTENNAS PERFORM AS DESIGNED. 47. PRIOR TO SETTING ANTENNA AZIMUTHS AND DOWNTILTS, ANTENNA CONTRACTOR SHALL CHECK THE ANTENNA MOUNT FOR TIGHTNESS AND ENSURE THAT THEY ARE PLUMB. ANTENNA AZIMUTHS SHALL BE SET FROM TRUE NORTH AND BE ORIENTED WITHIN +/- 5% AS DEFINED BY THE RFDS. ANTENNA DOWNTILTS SHALL BE WITHIN +/- 0.5% AS DEFINED BY THE RFDS. REFER TO ND-00246. 48. JUMPERS FROM THE TMA'S MUST TERMINATE TO OPPOSITE POLARIZATION'S IN EACH SECTOR. 49. CONTRACTOR SHALL RECORD THE SERIAL 1, SECTOR, AND POSITION OF EACH ACTUATOR INSTALLED AT THE ANTENNAS AND PROVIDE THE INFORMATION TO AT&T. 50. TMA'S SHALL BE MOUNTED ON PIPE DIRECTLY BEHIND ANTENNAS AS CLOSE TO ANTENNA AS FEASIBLE IN A VERTICAL POSITION. TORQUE REQUIREMENTS 51. ALL RF CONNECTIONS SHALL BE TIGHTENED BY A TORQUE WRENCH. 52. ALL RF CONNECTIONS, GROUNDING HARDWARE AND ANTENNA HARDWARE SHALL HAVE A TORQUE MARK INSTALLED IN A CONTINUOUS STRAIGHT LINE FROM BOTH SIDES OF THE CONNECTION. A. RF CONNECTION BOTH SIDES OF THE CONNECTOR. B. GROUNDING AND ANTENNA HARDWARE ON THE NUT SIDE STARTING FROM THE THREADS TO THE SOLID SURFACE. EXAMPLE OF SOLID SURFACE: GROUND BAR, ANTENNA BRACKET METAL. FIBER & POWER CABLE MOUNTING 53. THE FIBER OPTIC TRUNK CABLES SHALL BE INSTALLED INTO CONDUITS, CHANNEL CABLE TRAYS, OR CABLE TRAY. WHEN INSTALLING FIBER OPTIC TRUNK CABLES INTO A CABLE TRAY SYSTEM, THEY SHALL BE INSTALLED INTO AN INTER DUCT AND A PARTITION BARRIER SHALL BE INSTALLED BETWEEN THE 600 VOLT CABLES AND M THE INTER DUCT IN ORDER TO SEGREGATE CABLE TYPES. OPTIC FIBER TRUNK CABLES SHALL HAVE APPROVED CABLE RESTRAINTS EVERY (60) SIXTY FEET AND SECURELY FASTENED TO THE CABLE TRAY p SYSTEM. NFPA 70 (NEC) ARTICLE 770 RULES SHALL APPLY. 54. THE TYPE TC-ER CABLES SHALL BE INSTALLED INTO CONDUITS, CHANNEL CABLE TRAYS, OR CABLE TRAY AND SHALL BE SECURED AT INTERVALS NOT EXCEEDING (6) SIX FEET. AN EXCEPTION; WHERE TYPE TC-ER CABLES ARE NOT SUBJECT TO PHYSICAL DAMAGE, CABLES SHALL BE PERMITTED TO MAKE A TRANSITION BETWEEN CONDUITS, CHANNEL CABLE TRAYS, OR CABLE TRAY WHICH ARE SERVING UTILIZATION EQUIPMENT OR DEVICES, A DISTANCE (6) SIX FEET SHALL NOT BE EXCEEDED WITHOUT CONTINUOUS SUPPORTING. NFPA 70 (NEC) ARTICLES 336 AND 392 RULES SHALL APPLY. 55. WHEN INSTALLING OPTIC FIBER TRUNK CABLES OR TYPE TC-ER CABLES INTO CONDUITS, NFPA 70 (NEC) ARTICLE 300 RULES SHALL APPLY. 56-61 RESERVED FOR ADDITIONAL NOTES. COAXIAL CABLE NOTES 62. TYPES AND SIZES OF THE ANTENNA CABLE ARE BASED ON ESTIMATED LENGTHS. PRIOR TO ORDERING CABLE, CONTRACTOR SHALL VERIFY ACTUAL LENGTH BASED ON CONSTRUCTION LAYOUT AND NOTIFY THE PROJECT MANAGER IF ACTUAL LENGTHS EXCEED ESTIMATED LENGTHS. 63. CONTRACTOR SHALL VERIFY THE DOWN -TILT OF EACH ANTENNA WITH A DIGITAL LEVEL. 64. CONTRACTOR SHALL CONFIRM COAX COLOR CODING PRIOR TO CONSTRUCTION. 65. ALL JUMPERS TO THE ANTENNAS FROM THE MAIN TRANSMISSION LINE SHALL BE 1/2" DIA. LDF AND SHALL NOT EXCEED 6'-0". 66. ALL COAXIAL CABLE SHALL BE SECURED TO THE DESIGNED SUPPORT STRUCTURE, IN AN APPROVED MANNER, AT DISTANCES NOT TO EXCEED 4'-0" OC. 67. CONTRACTOR SHALL FOLLOW ALL MANUFACTURER'S RECOMMENDATIONS REGARDING BOTH THE INSTALLATION AND GROUNDING OF ALL COAXIAL CABLES, CONNECTORS, ANTENNAS, AND ALL OTHER EQUIPMENT. 68. CONTRACTOR SHALL GROUND ALL EQUIPMENT. INCLUDING ANTENNAS, RET MOTORS, TMA'S, COAX CABLES, AND RET CONTROL CABLES AS A COMPLETE SYSTEM. GROUNDING SHALL BE EXECUTED BY QUALIFIED WIREMEN IN COMPLIANCE WITH MANUFACTURER'S SPECIFICATION AND RECOMMENDATION. 69. CONTRACTOR SHALL PROVIDE STRAIN -RELIEF AND CABLE SUPPORTS FOR ALL CABLE ASSEMBLIES, COAX CABLES, AND RET CONTROL CABLES. CABLE STRAIN -RELIEFS AND CABLE SUPPORTS SHALL BE APPROVED FOR THE PURPOSE. INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. 70. CONTRACTOR TO VERIFY THAT EXISTING COAX HANGERS ARE STACKABLE SNAP IN HANGERS, IF EXISTING HANGERS ARE NOT STACKABLE SNAP IN HANGERS THE CONTRACTOR SHALL REPLACE EXISTING HANGERS WITH NEW SNAP IN HANGERS IF APPLICABLE. GENERAL CABLE AND EQUIPMENT NOTES 71. CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY ANTENNA, TMAS, DIPLEXERS, AND COAX CONFIGURATION, MAKE AND MODELS PRIOR TO INSTALLATION. 72. ALL CONNECTIONS FOR HANGERS, SUPPORTS, BRACING, ETC. SHALL BE INSTALLED PER TOWER MANUFACTURER'S RECOMMENDATIONS. 73. CONTRACTOR SHALL REFERENCE THE TOWER STRUCTURAL ANALYSIS/DESIGN DRAWINGS FOR DIRECTIONS ON CABLE DISTRIBUTION/ROUTING. 74. ALL OUTDOOR RF CONNECTORS/CONNECTIONS SHALL BE WEATHERPROOFED, EXCEPT THE RET CONNECTORS, USING BUTYL TAPE AFTER INSTALLATION AND FINAL CONNECTIONS ARE MADE. BUM TAPE SHALL HAVE A MINIMUM OF ONE-HALF TAPE WIDTH OVERLAP ON EACH TURN AND EACH LAYER SHALL BE WRAPPED THREE TIMES. WEATHERPROOFING SHALL BE SMOOTH WITHOUT BUCKLING. BUM BLEEDING IS NOT ALLOWED. 75. IF REQUIRED TO PAINT ANTENNAS AND/OR COAX: A. TEMPERATURE SHALL BE ABOVE 50' F. B. PAINT COLOR MUST BE APPROVED BY BUILDING OWNER/LANDLORD. C. FOR REGULATED TOWERS, FAA/FCC APPROVED PAINT IS REQUIRED. D. DO NOT PAINT OVER COLOR CODING OR ON EQUIPMENT MODEL NUMBERS. 76. ALL CABLES SHALL BE GROUNDED WITH COAXIAL CABLE GROUND KITS. FOLLOW THE MANUFACTURER'S RECOMMENDATIONS. A. GROUNDING AT THE ANTENNA LEVEL. B. GROUNDING AT MID LEVEL, TOWERS WHICH ARE OVER 200'-0", ADDITIONAL CABLE GROUNDING REQUIRED. C. GROUNDING AT BASE OF TOWER PRIOR TO TURNING HORIZONTAL. D. GROUNDING OUTSIDE THE EQUIPMENT SHELTER AT ENTRY PORT. E. GROUNDING INSIDE THE EQUIPMENT SHELTER AT THE ENTRY PORT. 77. ALL PROPOSED GROUND BAR DOWNLEADS ARE TO BE TERMINATED TO THE EXISTING ADJACENT GROUND BAR DOWNLEADS A MINIMUM DISTANCE OF 4'-0" BELOW GROUND BAR. TERMINATIONS MAY BE EXOTHERMIC OR COMPRESSION. Approved AT&T 1452 EDINGER AVENUE, 3RD FLOOR TUSTIN, CA 92780 4�� amentum 2 ASH STREET, ST #3000 CONSHOHOCKEN, PA 19428 s r c h 1 t e c t s c n g i n e e r s 5661 COLUMBIA PIKE, SUITE 200 FALLS CHURCH, VA 22041-2868 TEL (703) 671-6000 FAX: (703) 671-6300 REVISIONS REV. DATE DESCRIPTION INMALS A 01-23-25 ISSUED FOR REVIEW CG B 04-22-25 ISSUED FOR REVIEW SD 0 08-14-25 FINAL CD'S SD 1 09-05-25 FINAL CD'S SD 2 09-23-25 FINAL CD'S SD NOT FOR CONSTRUCTION UNLESS LABELED AS FOR CONSTRUCTION SI C�ql * C 90957 ,k s� 9 23. ZS �Q 9� CIVIC- F or C A\_ LICENSE NUMBER: C90957 EXPIRATION DATE: MARCH 31, 2026 SICA001875 10087160 2120 1/2 SOUTH BRISTOL SANTA ANA, CA 92704 SHEET TITLE NOTES AND SPECIFICATIONS SHEET NUMBER Sp-1 E <n 6 Ld m x O w a iJ U V) w U Ld w w w a U (E) 61'-0" MONOPOLF 0 w z z SCALE IN FEET O U a 0 40 80 160 240 z SITE PLAN -X ' X —1 FP �� CHAIN LINK SECURITY FENCE W ST GERTRUDE PL CIT, OF SANTA ANA Planning and Building Agency Approved E Re AT& t ; 1452 EDINGER AVENUE, 3RD FLOOR TUSTIN, CA 92780 amentum 2 ASH STREET, ST #3000 CONSHOHOCKEN, PA 19428 a r c h i t e c t s e n g i n e e r s 5661 COLUMBIA PIKE, SURE 200 FALLS CHURCH, VA 22041-2868 TEL (703) 671-6000 FAX: (703) 671-6300 REVISIONS REV. DATE DESCRIPTION INMALS A 01-23-25 ISSUED FOR REVIEW CG B 04-22-25 ISSUED FOR REVIEW SD 0 08-14-25 FINAL CD'S SD 1 09-05-25 FINAL CD'S SD 2 09-23-25 FINAL CD'S SD NOT FOR CONSTRUCTION UNLESS LABELED AS FOR CONSTRUCTION � N SI C�ql Q rn J X * C 90957 ,k s� 9 z3.2-S �Q 9� CIVIC (3� FOF CA`�F LICENSE NUMBER: C90957 EXPIRATION DATE: MARCH 31, 2026 SICA001875 10087160 2120 1/2 SOUTH BRISTOL SANTA ANA, CA 92704 SHEET TITLE SITE PLAN SHEET NUMBER TRUE NORTH A-0 SCALE:1 "=80' (11 x17) SCALE:1 "=40' (2436) CI -[:OF SANTA ANA Planning and Building Agency w m 5: n- o w a (N z W D 0 O 0 z 0 U z 0 U LL 0 Li V) V) z 0 W z z z 0 U z 0 a 0 z W (E) AT&T GENEi (E) CONCRETE (E) CHAIN LINK SECURITY FENC (E) ACCESS GA SCALE IN FEET 0 2.5 5 10 15 COMPOUND PLAN F—x —X —X —X X —X —X X —� x (TYP.) X X I x I x I x I X I X I x I X x i N\ -x /� — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — M U (E) & (N) AT&T EQUIPMENT IN (E) AT&T SHELTER (SEE SHEET A-1.1) TRUE NORTH SCALE:1 "=5' (11 x 17) SCALE:1 "=2.5' (2436) Approved to AT&T 1452 EDINGER AVENUE, 3RD FLOOR TUSTIN, CA 92780 amentum 2 ASH STREET, ST #3000 CONSHOHOCKEN, PA 19428 BC a r c h i t e c t s e n g i n c e r s 5661 COLUMBIA PIKE, SUITE 200 FALLS CHURCH, VA 22041-2868 TEL (703) 671-6000 FAX: (703) 671-6300 REVISIONS REV. DATE DESCRIPTION INMALS A 01-23-25 ISSUED FOR REVIEW CG B 04-22-25 ISSUED FOR REVIEW SD 0 08-14-25 FINAL CD'S SD 1 09-05-25 FINAL CD'S SD 2 09-23-25 FINAL CD'S SD NOT FOR CONSTRUCTION UNLESS LABELED AS FOR CONSTRUCTION SI0NgI �l Q 'P, rn * C 90957 ,k s� 9 z3. ZS �Q 9� IV I\- (3� F or CA LICENSE NUMBER: C90957 EXPIRATION DATE: MARCH 31, 2026 SICA001875 10087160 2120 1/2 SOUTH BRISTOL SANTA ANA, CA 92704 SHEET TITLE COMPOUND PLAN SHEET NUMBER A-1 E CITOF SANTA ANA Planning and Building Agency w m 0 w a iJ U V) w U Ld w w w a U 0 w (E) DISCONN x (E) AC PANE w N O J U 0 wI 0 (E) AT&T GS w to m (L) AI&I HU MCPA CABIN[ r m (E) AT&T RR 829 (TYP. 0 n- n- o a N I (E) AT&T BA r I TO REMAIN L (8) 12HTB21 U O 0 S W. 0 w z z SCALE IN FEET 0 U 0 0 2.5 5 10 15 z PROPOSED EQUIPMENT PLAN SCOPE OF WORK GROUND LEVEL 1. INSTALL (1) —48V RECTIFIER IN THE DC POWER PLANT \1/ ^ "" \1/ v-1 \ 1 / � I L) N'+O-LUUULJ KLI.I Ir ILKJ, lJ) 6648 & (1) DAFT IN (E) AT&T 1 C48241500-48/24V DC CONVERTERS FIF RACK & (12) (E) 12HTB21OF BATTERIES AT&T ICE BRIDGE AT&T TELCO BOX AT&T VENT AT&T UMTS 31NET (TYP.) AT&T GPS ENNA (TYP.) 9 CIENA BOX ALARM CLOCK AT&T WALL MOUNTED CABINET M DJ TRUE NORTH SCALE: 1"= 5' (11x17) SCALE:1 "=2.5' (2436) Approved AT&T ter�lQ:.. n; 1452 EDINGER AVENUE, 3RD FLOOR TUSTIN, CA 92780 amentum 2 ASH STREET, ST #3000 CONSHOHOCKEN, PA 19428 r c h i t e c t s n g i n e e r s 5661 COLUMBIA PIKE, SUITE 200 FALLS CHURCH, VA 22041-2868 TEL (703) 671-6000 FAX: (703) 671-6300 REVISIONS REV. DATE DESCRIPTION INRIALS A 01-23-25 ISSUED FOR REVIEW CG B 04-22-25 ISSUED FOR REVIEW SD 0 08-14-25 FINAL CD'S SD 1 09-05-25 FINAL CD'S SD 2 09-23-25 FINAL CD'S SD NOT FOR CONSTRUCTION UNLESS LABELED AS FOR CONSTRUCTION SICA001875 10087160 2120 1/2 SOUTH BRISTOL SANTA ANA, CA 92704 SHEET TITLE PROPOSED EQUIPMENT PLAN SHEET NUMBER A-1.1 E CIT, OF SANTA ANA Planning and Building Agency w m n- n- o w a (N r z W U O 0 z 0 U 2 0 0 LL O V) V) z 0 W z z z 0 0 z 0 a 0 z W R48-2000E3 RECTIFIER DETAIL 1m4-210mliammilmul DC OUTPUT VOLTAGE DC OUTPUT POWER AND CURRENT POWER DERATING BASED ON INPUT VOLTAGE POWER DERATING BASED ON TEMPERATURE AC INPUT VOLTAGE PERMITTED VARIATION HARMONIC CONTENT OPERATING AMBIENT TEMPERATURE RANGE TEMPERATURE COEFFICIENT RELATIVE HUMIDITY ALTITUDE SURGE PROTECTION HIGH VOLTAGE CATEGORY SINGLE RECTIFIER AUDIBLE NOISE POWER DISTRIBUTION SYSTEM EMC EMI LOAD RANGE SAFETY DIMENSIONS (H X W X D) WEIGHT —42 VDC TO —58 VDC 2000W (41.7A) ® 120/208/240 VAC INPUT AND —48VDC OUTPUT 176 VAC TO 300 VAC +55 'C (+131 'F) NOMINAL 120/208/240 VAC 85 TO 300 VAC S 5% FROM 50% TO 100% OF RATED LOAD +55 'C (+131 'F) TO +80 'C (+176 'F) WITH DERATING OUTPUT —40 'C (-40 'F) TO +55 'C (+131 'F) WITH FULL POWER PERFORMANCE 0.02% PER DEGRESS CELSIUS 0 TO 95% 2000M / 6560 FT AT FULL POWER COMPLIANCE WITH EN61000-4-5 II AT +25 'C S 50 DB(A) TN/Tr/IT ETSI EN 386, FCC CFR 47 PART 15 CLASS B, TELCORDIA GR-1089—CORE 10 — 100% IEC 60950, EN 60950, UL 60950 42.0 (HEIGHT) X 84.5 (WIDTH) X 252.5 (DEPTH) IN MM 1.7 (HEIGHT) X 3.3 (WIDTH) X 9.9 (DEPTH) IN INCHES 1.13 KG (2.49 LBS) M U Approved AT&T ter�lQ:.. 1452 EDINGER AVENUE, 3RD FLOOR TUSTIN, CA 92780 i� amentum 2 ASH STREET, ST #3000 CONSHOHOCKEN, PA 19428 BC r c h i t e c t s e n g i n e e r s 5661 COLUMBIA PIKE, SUITE 200 FALLS CHURCH, VA 22041-2868 TEL (703) 671-6000 FAX: (703) 671-6300 REVISIONS REV. DATE DESCRIPTION INMALS A 01-23-25 ISSUED FOR REVIEW CG B 04-22-25 ISSUED FOR REVIEW SD 0 08-14-25 FINAL CD'S SD 1 09-05-25 FINAL CD'S SD 2 09-23-25 FINAL CD'S SD NOT FOR CONSTRUCTION UNLESS LABELED AS FOR CONSTRUCTION � N SI�NgI �l Q 'P, rn J X * C 90957 ,k s� 9 Z3. ZS �Q 9� CIVIC (3� F pF CA \- LICENSE NUMBER: C90957 EXPIRATION DATE: MARCH 31, 2026 SICA001875 10087160 2120 1/2 SOUTH BRISTOL SANTA ANA, CA 92704 SHEET TITLE GROUND EQUIPMENT DETAIL SHEET NUMBER A-1.2 1 E CITY OF SANTA ANA Planning and Building Agency w m n- n- o a (N r z W m D U O 0 Z 0 U Z 0 0 LL O Li V) V) z 0 W Z z z 0 0 z 0 a 0 Z W S2 w _ cD w a o = 1= O a -_ � I o O cf o L0 o a Q o= w U c z w a O U(N 01 � w z w U � A p Id a mm 0 cif U as = ~o Q Q w w W r7 SCALE IN FEET 0 5 10 20 30 EXISTING SOUTH ELEVATION AT&T EQUIPMENT: ANTENNAS (TO REMAIN) ANTENNA (TO BE RELOCATED) RRU'S (TO BE REMAIN) AT&T ALPHA SECTOR ANTENNA'S ON (E) SECTOR FRAME ANTENNAS (TYP.) (7) (E) AT&T WR-VO86ST-BRD DC TRUNKS, (3) 0.39" FIBER TRUNKS, (18) = w LDF5-50A COAX CABLES, (1) 123-171-XX w a RET CABLE IN 2" INNERDUCT CONDUIT of o o o 0- Z I o z 0 Q —(E) MONOPOLE (E) & (N) AT&T EQUIPMENT IN (E) EQUIPMENT SHELTER (E) CHAIN LINK SECURITY FENCE tz w W W z z C a � En C' O O N Cn O N I M io w tn d L U' � a m m o g m Q � a � LLf v L..i SCALE IN FEET 0 5 10 20 30 SCALE:1 "=10' (11 x 17) SCALE: 1"=5' (2436) 1 1 PROPOSED SOUTH ELEVATION (N) AT&T EQUIPMENT: (1) ANTENNA E) AT&T ALPHA SECTOR ANTENNA'S ON (E) SECTOR FRAME (E) & (N) AT&T EQUIPMENT IN (E) EQUIPMENT SHELTER (E) CHAIN LINK SECURITY FENCE Approved AT&T M ter�lQ:.. D t ; 1452 EDINGER AVENUE, 3RD FLOOR TUSTIN, CA 92780 amentum 2 ASH STREET, ST #3000 CONSHOHOCKEN, PA 19428 BC r c h i t e c t s n g i n e e r s 5661 COLUMBIA PIKE, SUITE 200 FALLS CHURCH, VA 22041-2868 TEL (703) 671-6000 FAX: (703) 671-6300 REVISIONS REV. DATE DESCRIPTION INRIALS A 01-23-25 ISSUED FOR REVIEW CG B 04-22-25 ISSUED FOR REVIEW SD 0 08-14-25 FINAL CD'S SD 1 09-05-25 FINAL CD'S SD 2 09-23-25 FINAL CD'S SD NOT FOR CONSTRUCTION UNLESS LABELED AS FOR CONSTRUCTION NSI0NgI Q 'P, rn * C 90957 ,k s� 9 Z3. ZS �Q 9� C (3� let,CIVI pF CA LICENSE NUMBER: C90957 EXPIRATION DATE: MARCH 31, 2026 SICA001875 10087160 2120 1/2 SOUTH BRISTOL SANTA ANA, CA 92704 SHEET TITLE EXISTING & PROPOSED SOUTH TOWER ELEVATION SHEET NUMBER A-2 SCALE:1 "=10' (11 x 17) 1 2 SCALE:1 "=5' (24x36) E CITY OF SANTA ANA Planning and Building Agency w } m n- n- o a (N r z W m U O 0 z 0 U 2 0 U U- O Iz V) V) z 0 z z z z 0 0 z 0 a 0 z W SCALE IN FEET 0 5 10 20 30 EXISTING EAST ELEVATION SCALE IN FEET 0 5 10 20 30 SCALE:1 "=10' (11 x 17) SCALE:1"=5' (2436) 1 1 PROPOSED EAST ELEVATION N) AT&T EQUIPMENT: 1) ANTENNA Approved AT&T M ter�lQ:.. D t ; 1452 EDINGER AVENUE, 3RD FLOOR TUSTIN, CA 92780 amentum 2 ASH STREET, ST #3000 CONSHOHOCKEN, PA 19428 BC r c h i t e c t s e n g i n e e r s 5661 COLUMBIA PIKE, SUITE 200 FALLS CHURCH, VA 22041-2868 TEL (703) 671-6000 FAX: (703) 671-6300 REVISIONS REV. DATE DESCRIPTION INMALS A 01-23-25 ISSUED FOR REVIEW CG B 04-22-25 ISSUED FOR REVIEW SD 0 08-14-25 FINAL CD'S SD 1 09-05-25 FINAL CD'S SD 2 09-23-25 FINAL CD'S SD NOT FOR CONSTRUCTION UNLESS LABELED AS FOR CONSTRUCTION - � IESN SI0NgI Q v rn J X * C 90957 ,k s� 9 Z3. ZS �Q 9� CIVIC (3� FOF CA`�F LICENSE NUMBER: C90957 EXPIRATION DATE: MARCH 31, 2026 SICA001875 10087160 2120 1/2 SOUTH BRISTOL SANTA ANA, CA 92704 SHEET TITLE EXISTING & PROPOSED EAST TOWER ELEVATION SHEET NUMBER A-2.1 SCALE: 1"=10' (11x17) 2 SCALE:1 "=5' (24x36) 11 E CITOF SANTA ANA Planning and Building Agency NOTES: 1. GENERAL CONTRACTOR IS TO FIELD VERIFY ALL EXISTING ANTENNA RAD CENTERS, ANTENNA TIP HEIGHTS WITH A PRE -TAPE DROP, AND AZIMUTHS PRIOR TO CONSTRUCTION. ALL CHANGES TO THE ANTENNA POSITIONS, AZIMUTHS, AND RAD CENTERS NEED TO BE DISCUSSED WITH RF AND AT&T FIELD CONSTRUCTION MANAGER. ALL CHANGES SHALL BE NOTED ON CONSTRUCTION AS BUILTS. 2. TOWER AND TOWER FOUNDATION DESIGN HAS BEEN PREPARED AND PROVIDED BY OTHERS. REFER TO MANUFACTURER'S APPROVED TOWER DRAWINGS OR CURRENT STRUCTURAL ANALYSIS. THE RF RAD CENTER OF THE PROPOSED ANTENNAS AND MOUNTING PLATFORM ARE BASED ON INFORMATION PROVIDED THROUGH AT&T. 3. THIS DRAWING IS A GRAPHICAL REPRESENTATION OF THE TOWER, THE RF RAD CENTER OF THE PROPOSED ANTENNAS AND PROPOSED MOUNTING PLATFORM/SECTOR FRAME BASED ON INFORMATION PROVIDED THROUGH AT&T, AND /OR ANALYZED BY OTHERS. BC ARCHITECTS ENGINEERS CERTIFIES ONLY THAT INFORMATION PROVIDED TO BC ARCHITECTS ENGINEERS FOR THE PREPARATION OF THESE PLANS AND IS NOT CERTIFYING NOR WARRANTING THE DESIGN NOR VERIFYING THE ANALYTICAL RESULTS OF THE STRUCTURAL ANALYSIS PERFORMED BY OTHERS 4. THE CONTRACTOR SHALL VERIFY THE LOCATION OF THE PROPOSED CABLES, CABLE LADDER, AND/OR OTHER CABLE SUPPORTING SYSTEM PER CURRENT STRUCTURAL ANALYSIS. 5. ALL COAX CABLES SHALL BE STACKED IN ACCORDANCE WITH THE CURRENT STRUCTURAL ANALYSIS. THE CONTRACTOR OR SUBCONTRACTOR SHALL FURNISH AND INSTALL CABLE LADDER RACK, CABLE TRAYS, ETC., AND/OR CONDUIT AS REQUIRED TO SUPPORT CABLES 0 m 6. THE CONTRACTOR SHALL VERIFY WITH CONSTRUCTION TURF VENDORS 48 HOURS PRIOR TO INSTALLATION OF ALL EQUIPMENT/RF CONFIGURATION AND o ANY RELATED WORK RELATED TO THE COMPLETION OF THIS PROJECT. w � 7. THIS DRAWING IS FOR GENERAL INFORMATION ONLY U V) w U w w a U 0 w g ROTATE (E) AT&T GAMMA SECTOR MOUNT TO MATCH AZIMUTHS — RELOCATE (E) AT&T = INTEGRATED ANTENNA (TYP. 1 3 I PER SECTOR, 3 TOTAL) a (E) AT&T PANEL ANTENNA (TYP. 3 PER ~ SECTOR, 9 TOTAL) w 0 w o (E) AT&T RRUS 32 B30 (TYP. 1 PER SECTOR, 3 TOTAL) U w (E) AT&T 4449 B5/1312 (TYP. V) 1 PER SECTOR, 3 TOTAL) zla Lj #B1 m P n_o ���1 o a (N z w (E) AT&T 8843 B2/1366A (TYP. 1 U 0 1 PER SECTOR, 3 TOTAL) z 0 U 0 U U_ 0 U) VIz w z 01 z SCALE IN FEET o I IYimme�■ v 12" 0 2,-0 4,-0 6'-0" 0 z EXISTING ANTENNA PLAN #C #B4 o TOWER SCOPE OF WORK: ** RELOCATE POS2 MAST PIPE TO ACHIEVE 24" SEPARATIONS** TOPSIDE: 1. REPLACE POS 2 MAST PIPES W/ 2-7/8" (1) PER SECTOR 2. INSTALL (3) AIR6419 B77G ANTENNAS STACKED ABOVE THE (E) AIR6449 B77D ON POS A2,82,C2 m cr I o v; #C1 � n 2-0 � I� - " � #A4 Un. v ° v C3 SECTOR ALPHq # AZ=10p• C4 (E) AT&T 4478 B14 (TYP. 1 PER SECTOR, 3 TOTAL) #A3 #B1 SECTOR ALPHq AZ=100° EMOVE (E) PIPE MAST (TYP. 1 PER SECTOR, 3 TOTAL) #B #A2 SECTOR ALp �P AZ=100' � d #B3 (E) AT&T DC6 (TYP. OF 4) �Q Q o o - #B4 SECTOR ALPHA / #A1 AZ=100° /t TRUE NORTH SCALE:1 4"=1' 11x17 SCALE:1/2"=1' (2436 SCALE IN FEET 12 0 2'-0" 4'-0" 6'-0" PROPOSED ANTENNA PLAN Q5 m CA v; U 2',0„ #A3 i N i N NOTE: GROUND ALL (N) EQUIPMENT TO GROUND BARS WITH THE APPROPRIATE GROUND WIRE SIZES AND TYPES DETERMINED BY MFG & AT&T SPECIFICATIONS SECTOR ALPHq AZ=100° INSTALL (N) AT&T 2-7/8" OD X 10' PIPE MAST USING XF-2525 CROSSOVER PLATE (TYP. 1 PER SECTOR, 3 TOTAL) 447 SECTOR ALPHA #A1 AZ=100° INSTALL (N) AT&T AIR6419 B77G INTEGRATED ANTENNA ABOVE (E) RELOCATED AIR6449 B77D INTEGRATED ANTENNA (TYP. 1 PER SECTOR, 3 TOTAL) TRUE NORTH SCALE: 1 /2"=1 ' ( (2436) 2 Approved \�= °;, AT&T . te1gQ:..�� � . m 1452 EDINGER AVENUE, 3RD FLOOR TUSTIN, CA 92780 amentum 2 ASH STREET, ST #3000 CONSHOHOCKEN, PA 19428 r c h i t e c t s n i n e e r s 5661 COLUMBIA PIKE, SUITE 200 FALLS CHURCH, VA 22041-2868 TEL (703) 671-6000 FAX: (703) 671-6300 REVISIONS REV. DATE DESCRIPTION INRIALS A 01-23-25 ISSUED FOR REVIEW CG B 04-22-25 ISSUED FOR REVIEW SD 0 08-14-25 FINAL CD'S SD 1 09-05-25 FINAL CD'S SD 2 09-23-25 FINAL CD'S SD NOT FOR CONSTRUCTION UNLESS LABELED AS FOR CONSTRUCTION SICA001875 10087160 2120 1/2 SOUTH BRISTOL SANTA ANA, CA 92704 SHEET TITLE EXISTING & PROPOSED ANTENNA PLAN SHEET NUMBER A-3 E CITOF SANTA ANA Planning and Building Agency 0 m x 0 w a iJ U w U Uj w W w a U 0 U) g w x U 3 a z a x LU w 0 w N O J U 0 0 w rn z a 4i r m n- n- o w a (N r z w U O 0 z 0 U z z 0 U U- O Li U) U) z 0 w z z z 0 U z 0 a 0 z w THE DESIGN SHOWN IN THESE DRAWINGS IS BASED ON INFORMATION GATHERED FROM AT&T RFDS ID: RFDS-34561 DATED 11/05/2024 SECTOR 1 DC SURGE/DISTRIBUTION & COAX/DC/FIBER SECTOR ANTENNA ANTENNA MAKE MODEL RAD. CTR TOP OF AZIMUTH RRH TECHNOLOGY POSITION FT. AGL. ANTENNAS LTE 700 LTE 850 #1 COMMSCOPE NNH4-65C-R6-V3 57'-0" 61'-0" 100° (1) (E) 4449 B5/B12 LTE 1900 (1) (E) 8843 B2/B66A LTE AWS CBAND #2 ERICSSON AIR6449 B77D 59'-0" 60'-2" 100' INTEGRATED ALPHA LTE 700 #3 KATHREIN 80010966 57'-0" 61'-0" 100° (1) (E) 4478 B14 (E) RRUS-32 B30 LTE WCS #4 KATHREIN 80010866 57'-0" 61'-0" 100° j(1) (1) (E) RRUS-E2 B29 LTE 700 GROUND SECTOR 2 SECTOR ANTENNA TECHNOLOGY ANTENNA MAKE MODEL RAD. CTR FT. AGL. TOP OF AZIMUTH RRH POSITION ANTENNAS LTE 850 #1 COMMSCOPE (1) (E) 4449 B5/B12 LTE 1900 NNH4-65C-R6-V3 57'-0" 61'-0" 220° (1) (E) 8843 32/1366A LTE AWS (4) (E) DC6-48-60-18-8F CBAND #2 ERICSSON AIR6449 B77D 59'-0" 60'-2" 220' INTEGRATED (7) (E) WR-VG86ST-BRD DC BETA TRUNKS (3) (E) 0.39" PAIR FIBER TRUNKS LTE 700 #3 KATHREIN 80010966 57'-0" 61'-0" 220` (1) (E) 4478 B14 18) (E) LDF5-50A COAX CABLES (1) (E) 123-171-XX COAX CABLES LTE WCS #4 KATHREIN 80010866 57'-0" 61'-0" 220° (1) (E) RRUS-32 B30 (1) (E) 2" INNERDUCT CONDUIT LTE 700 (1) (E) RRUS-E2 B29 GROUND SECTOR 3 SECTOR ANTENNA ANTENNA MAKE MODEL RAD. CTR TOP OF AZIMUTH RRH TECHNOLOGY POSITION FT. AGL. ANTENNAS LTE 700 LTE 850 #1 COMMSCOPE NNH4-65C-R6-V3 57'_0" 61'-0" 340° (1) (E) 4449 B5/B12 LTE 1900 (1) (E) 8843 32/1366A LTE AWS CBAND #2 ERICSSON AIR6449 B77D 59'-0" 60'-2" 340' INTEGRATED GAMMA LTE 700 #3 KATHREIN 80010966 57'-0" 61'-0" 340° (1) (E) 4478 B14 (E) RRUS-32 B30 LTE WCS # 4 KATHREIN 80010866 57'-0" 61'-0" 340° 1(1) (1) (E) RRUS-E2 B29 LTE 700 GROUND M U SECTOR 1 DC SURGE/DISTRIBUTION & COAX/DC/FIBER SECTOR ANTENNA ANTENNA MAKE MODEL RAD. CTR TOP OF AZIMUTH RRH TECHNOLOGY POSITION FT. AGL. ANTENNAS LTE 700 LTE 850 (1) (E) 4449 B5/B12 LTE 1900 #1 COMMSCOPE NNH4-65C-R6-V3 57'-0" 61'-0" 100' (1) (E) 8843 132/1366A LTE AWS 513 DOD AIR6419 B77G 59'-10" INTEGRATED 5G CBAND #2 ERICSSON AIR6449 B77D 56'-6" „ 61 -0 10Or INTEGRATED ALPHA LTE 700 #3 KATHREIN 80010966 57'-0" 61'-0" 100° (1) (E) 4478 B14 (1) (E) RRUS-32 B30 LTE WCS #4 KATHREIN 80010866 57'-0" 61'-0" 100' (1) (E) RRUS-E2 B29 LTE 700 GROUND SECTOR 2 SECTOR ANTENNA TECHNOLOGY ANTENNA MAKE MODEL RAD. CTR TOP OF AZIMUTH RRH POSITION FT. AGL. ANTENNAS LTE 700 LTE 850 (1) (E) 4449 B5/B12 LTE 1900 #1 COMMSCOPE NNH4-65C-R6-V3 57'_0" 61'-0" 220" (1) (E) 8843 32/1366A LTE AWS (4) (E) DC6-48-60-18-8F 5G DOD # 2 ERICSSON AIR6419 B77G AIR6449 B77D 59-10" 56'-6" 61 -0 220' INTEGRATED BETA 5G CBAND INTEGRATED (7) (E) WR-VG86ST-BRD DC TRUNKS LTE 700 #3 KATHREIN 80010966 57'-0" 61'-0" 220' (1) (E) 4478 B14 (3) (E) 0.39" PAIR FIBER TRUNKS 18) (E) LDF5-50A COAX CABLES (1) (E) 123-171-XX COAX CABLES (1) (E) RRUS-32 B30 LTE WCS #4 KATHREIN 80010866 57'-0" 61'-0" 220° (1) (E) RRUS-E2 B29 (1) (E) 2" INNERDUCT CONDUIT LTE 700 GROUND SECTOR 3 SECTOR ANTENNA ANTENNA MAKE MODEL RAD. CTR TOP OF AZIMUTH RRH TECHNOLOGY POSITION FT. AGL. ANTENNAS LTE 700 LTE 850 (1) (E) 4449 135/1312 LTE 1900 #1 COMMSCOPE NNH4-65C-R6-V3 57'-O" 61'-0" 355' (1) (E) 8843 B2/B66A LTE AWS 513 DOD #2 ERICSSON 596 =16 „ 61'-0" 355' INTEGRATED 5G CBAND AIR6449 B77D INTEGRATED GAMMA LTE 700 #3 KATHREIN 80010966 57'-0" 61'-0" 355' (1) (E) 4478 B14 (1) (E) RRUS-32 B30 LTE WCS #4 KATHREIN 80010866 57'-0" 61'-0" 355' (1) (E) RRUS-E2 B29 LTE 700 (GROUND) EXISTING ANTENNA SCHEDULE 1 1 (PROPOSED ANTENNA SCHEDULE Approved AT&T ter,lQ:.. 1452 EDINGER AVENUE, 3RD FLOOR TUSTIN, CA 92780 amentum 2 ASH STREET, ST #3000 CONSHOHOCKEN, PA 19428 r c h i t e c t s n g s n e e r s 5661 COLUMBIA PIKE, SUITE 200 FALLS CHURCH, VA 22041-2868 TEL (703) 671-6000 FAX: (703) 671-6300 REVISIONS REV. DATE DESCRIPTION INRIALS A 01-23-25 ISSUED FOR REVIEW CG B 04-22-25 ISSUED FOR REVIEW SD 0 08-14-25 FINAL CD'S SD 1 09-05-25 FINAL CD'S SD 2 09-23-25 FINAL CD'S SD NOT FOR CONSTRUCTION UNLESS LABELED AS FOR CONSTRUCTION SICA001875 10087160 2120 1/2 SOUTH BRISTOL SANTA ANA, CA 92704 SHEET TITLE EXISTING & PROPOSED ANTENNA SCHEDULE SHEET NUMBER A-4 2 E CIT, OF SANTA ANA Planning and Building Agency 0 W H m x 0 w a iJ U rn rn w U w w U O w g w x _U x 3 x z x H Uj w 0 w N En U 0 0 w to z w m n- n- o a (N z w U 0 0 z 0 U O U w 0 En rn z 0 w z zz 0 U z O a 0 z w (N) AT&T XF CROSSOVER (N) AT&T All INTEGRATED (N) 2-7/8' X 10' PIPE POSITION 12 (ALL SECTORS) ANTENNA MOUNTING DETAIL I N.T.S 1 1 1 N y 7.9" ERICSSON AIR 6419 B77G DIMENSIONS, HxWxD: 28.3*06.1"x7.9" POWER CONSUMPTION: 1200 WATTS 0 MAX LOAD TOTAL WEIGHT: 66.1 LBS PORTS: 20 0/25 GBPS eCPRI PORTS NOTES: 1.0 GENERAL 1,1 ALL METRIC DIMENSIONS ARE IN BRACKETS 1,2 FOR PATENTS, SEE WWW.CS-PAT.COM 2.0 DESIGN NOTES 3.0 MANUFACTURING/SPECIAL REQUIRMENTS 4.0 TEST 5.0 PACKAGING PRODUCT PLATE (CITY 1) U-BOLT #1 CITY U-BOLT #2 CITY XP-2020 XPU01 GUB-4240 4 - - XP-2025 XPU01 GUB-4240 2 GUB-4352 2 XP-2030 XPU01 GUB-4240 2 GUB-4355 2 /fig XP-2035 XPU02 GUB52440 2 GUB-53560 2 XP-2040 XPU02 GUB52440 2 GUB-5456 2 XP-2525 XPU01 GUB-4352 4 - - XP-2530 XPU01 GUB-4352 2 GUB-4355 2 XP-2540 XPU02 GUB-53045 2 GUB-5456 2 XP-3030 XPU01 GUB-4355 4 - - XP-3040 XPU02 GUB-53560 2 GUB-5456 2 XP-4040 XPU02 GUB-5456 4 - - R6419 B77G ANTENNA DETAIL I N.T.S 121 XP-2525 CROSSOVER PLATE DETAIL REVISIONS REV, ECN DESCRIPTION BY DATE A 8=WS681 INTIAL RELEASE RDLS 07103/18 B 8D0 6044 1 ADDED XP-2035 ES 711812019 COMMSCOPE, INC. OF NORTH CAROLINA 70LERANCES SAP MATERIAL MASTER 1PLACE .Xf .25 3PLACE.XXXt 0.06 SEE TABLE 2 PLACE ,XX t 0.12 ANGLES t 2° FINISH MATERIAL GALV A123 A10111A1018 GR 36 DENSITY 0,28 Ibslin' MASS 12,61 IbB VOLUME 45.33 In' SURFACE AREA in, HEIGHT LENGTH C 2019 Comm5cope, Inc. Confidential WIDTH I $ _ � NAME DATE TITLE XP SERIES CE RW RV AD SCALE �1111UMENTNO, 1:1 XP SERIES RE EON 008000036044 SIZE WORKAREA 24 MODEL DRAWING VERSION STATUS REVISION VERSION STATUS REV18 01 RE B 01 1 RE B SHEET 1 OF 1 N.T.S M DI Approved AT&T ter�lQ:.. ?; 1452 EDINGER AVENUE, 3RD FLOOR TUSTIN, CA 92780 i� amentum 2 ASH STREET, ST #3000 CONSHOHOCKEN, PA 19428 BC r c h i t e c t s e n g i n e e r s 5661 COLUMBIA PIKE, SUITE 200 FALLS CHURCH, VA 22041-2868 TEL (703) 671-6000 FAX: (703) 671-6300 REVISIONS REV. DATE DESCRIPTION INMALS A 01-23-25 ISSUED FOR REVIEW CG B 04-22-25 ISSUED FOR REVIEW SD 0 08-14-25 FINAL CD'S SD 1 09-05-25 FINAL CD'S SD 2 09-23-25 FINAL CD'S SD NOT FOR CONSTRUCTION UNLESS LABELED AS FOR CONSTRUCTION � N SI C�ql Q 'P, rn J X * C 90957 ,k s� 9 Z3. ZS �Q 4 CIVIC- (3� F pF 0 A`�F LICENSE NUMBER: C90957 EXPIRATION DATE: MARCH 31, 2026 SICA001875 10087160 2120 1/2 SOUTH BRISTOL SANTA ANA, CA 92704 SHEET TITLE TOWER EQUIPMENT DETAILS SHEET NUMBER A-5 E w r m n_ a o w a (N r z W m U O 0 z 0 U 2 0 0 LL O F W N V) z 0 W z z z 0 0 z 0 a 0 z W GROUNDING NOTES GROUNDING NOTES 1. GROUNDING SHALL COMPLY WITH NEC ART. 250. ADDITIONALLY, GROUNDING, BONDING AND LIGHTING PROTECTION SHALL BE ADVERSE FINDINGS TO THE CONTRACTOR FOR RESOLUTION. DONE IN ACCORDANCE WITH METRO MOD CELL SITE GROUNDING STANDARDS. 12. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION, AND AC POWER GES'S) 2. GROUND CABLE SHIELDS MINIMUM AT BOTH ENDS USING MANUFACTURERS CABLE GROUNDING KITS SUPPLIED BY PROJECT SHALL BE BONDED TOGETHER, AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE OWNER. WITH THE NEC. 3. USE #6 COPPER STRANDED WIRE WITH GREEN COLOR INSULATION FOR ABOVE GRADE GROUNDING (UNLESS OTHERWISE 13. THE SUBCONTRACTOR SHALL PERFORM IEEE FALL —OF —POTENTIAL RESISTANCE TO EARTH TESTING (PER IEEE 1100 AND 81) SPECIFIED) AND #2 SOLID TINNED BARE COPPER WIRE FOR BELOW GRADE GROUNDING AS INDICATED ON THE DRAWING. FOR NEW GROUND ELECTRODE SYSTEMS. THE SUBCONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. 4. ALL POWER AND GROUND CONNECTIONS TO BE CRIMP —STYLE, COMPRESSION WIRE LUGS AND WIRE NUTS BY HARGER (OR APPROVED EQUAL) RATED FOR OPERATION AT NO LESS THAN 75-C OR CADWELD EXOTHERMIC WELD. DO NOT ALLOW BARE 14. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER COPPER WIRE TO BE IN CONTACT WITH GALVANIZED STEEL.. CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. 5. ROUTE GROUNDING CONDUCTORS ALONG THE SHORTEST AND STRAIGHTEST PATH POSSIBLE, EXCEPT AS OTHERWISE INDICATED. GROUNDING LEADS SHOULD NEVER BE BENT AT RIGHT ANGLE. ALWAYS MAKE AT LEAST 12' RADIUS BENDS. #6 WIRE CAN 15. EACH BTS CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED BE BENT AT 6' RADIUS WHEN NECESSARY. BOND ANY METAL OBJECTS WITHIN 6 FEET OF PROJECT OWNER EQUIPMENT OR SUPPLEMENTAL EQUIPMENT GROUND WIRES, 6 AWG STRANDED COPPER OR LARGER FOR INDOOR BTS; 2 AWG SOLID COPPER CABINET TO MASTER GROUND BAR OR GROUNDING RING. FOR OUTDOOR BTS. 6. CONNECTIONS TO GROUND BARS SHALL BE MADE WITH TWO HOLE COMPRESSION TYPE COPPER LUGS. APPLY OXIDE 16. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. INHIBITING COMPOUND TO ALL LOCATIONS. 17. APPROVED ANTIOXIDANT COATINGS (I.E., CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED 7. APPLY OXIDE INHIBITING COMPOUND TO ALL MECHANICAL GROUND CONNECTIONS. GROUND CONNECTIONS. 18. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED WITH STAINLESS STEEL HARDWARE TO 8. CONTRACTOR SHALL PROVIDE AND INSTALL OMNI DIRECTIONAL ELECTRONIC MARKER SYSTEM (EMS) BALLS OVER EACH THE BRIDGE AND THE TOWER GROUND BAR. GROUND ROD AND BONDING POINT BETWEEN EXISTING TOWER/ MONOPOLE GROUNDING RING AND EQUIPMENT GROUNDING RING. 19. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS. 9. CONTRACTOR SHALL TEST COMPLETED GROUND SYSTEM AND RECORD RESULTS FOR PROJECT CLOSE—OUT DOCUMENTATION. 5 20. MISCELLANEOUS ELECTRICAL AND NON —ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE OHMNS MINIMUM RESISTANCE REQUIRED. GROUND RING, IN ACCORDANCE WITH THE NEC. 10. CONTRACTOR SHALL CONDUCT ANTENNA, CABLE, AND LNA RETURN —LOSS AND DISTANCE —TO —FAULT MEASUREMENTS (SWEEP 21. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH 6 AWG COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT CLAMPS. TESTS) AND RECORD RESULTS FOR PROJECT CLOSE OUT. 22. GROUND CONDUCTORS USED IN THE FACILITY GROUND AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED 11. THE SUBCONTRACTOR SHALL REVIEW AND INSPECT THE EXISTING FACILITY GROUNDING SYSTEM AND LIGHTNING PROTECTION THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC CONDUITS, METAL SUPPORT SYSTEM (AS DESIGNED AND INSTALLED) FOR STRICT COMPLIANCE WITH THE NEC (AS ADOPTED BY THE AHJ), THE CUPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE SITE —SPECIFIC (UL, LPI, OR NFPA) LIGHTING PROTECTION CODE, AND GENERAL COMPLIANCE WITH TELCORDIA AND TIA REQUIREMENTS OR LOCAL CONDITIONS, NON—METALLIC MATERIAL SUCH AS PVC PLASTIC CONDUIT SHALL BE USED. WHERE GROUNDING STANDARDS. THE USE OF METAL CONDUIT IS UNAVOIDABLE (E.G., NON—METALLIC CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND SUBCONTRACTOR SHALL REPORT ANY VIOLATIONS OR CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. CIT, OF SANTA ANA Planning and Building Agency Approved ono PERMIT iccl in nlr-E M U AT&T 1452 EDINGER AVENUE, 3RD FLOOR TUSTIN, CA 92780 amentum 2 ASH STREET, ST #3000 CONSHOHOCKEN, PA 19428 Bc r c h i t e c t s e n g i n e e r s 5661 COLUMBIA PIKE, SUITE 200 FALLS CHURCH, VA 22041-2868 TEL (703) 671-6000 FAX: (703) 671-6300 REVISIONS REV. DATE DESCRIPTION INMALS A 01-23-25 ISSUED FOR REVIEW CG B 04-22-25 ISSUED FOR REVIEW SD 0 08-14-25 FINAL CD'S SD 1 09-05-25 FINAL CD'S SD 2 09-23-25 FINAL CD'S SD NOT FOR CONSTRUCTION UNLESS LABELED AS FOR CONSTRUCTION ()� N SI C�ql �l Q 'P, rn J X * C 90957 ,k s� 9Z39 �Q 9� CIVIC - Or CA��� LICENSE NUMBER: C90957 EXPIRATION DATE: MARCH 31, 2026 SICA001875 10087160 2120 1 /2 SOUTH BRISTOL SANTA ANA, CA 92704 SHEET TITLE GROUNDING NOTES SHEET NUMBER E-1 1 w } m n- n- o w a (N r z W m U O 0 z 0 U 2 0 U LL O F W V) V) x z 0 w z zz 0 U z 0 a 0 z W PLUMBING DIAGRAM (ALPHA SECTOR 5ectoi- A A%sis IBM •� x := ' x x x x x x x x x x x x x .f �. u u ,I 111GAi10I7iMK s1a oil iwu .rs lR 170N'4+�f ■■■M1I■M11 SEES■■■ SEES SEEM mass ■am i i E 0 C 6 A 6b30 L45 DoO A06411 •77G Hatch Plate aQKRtR i. u tTt man M am u .-j - fT CI -[:OF SANTA ANA Planning and Building Agency Approved ono PERMIT icci in nir-E M U AT&T ter�lQ:.. 1452 EDINGER AVENUE, 3RD FLOOR TUSTIN, CA 92780 amentum 2 ASH STREET, ST #3000 CONSHOHOCKEN, PA 19428 BC r c h i t e c t s e n g i n e e r s 5661 COLUMBIA PIKE, SUITE 200 FALLS CHURCH, VA 22041-2868 TEL (703) 671-6000 FAX: (703) 671-6300 REVISIONS REV. DATE DESCRIPTION INMALS A 01-23-25 ISSUED FOR REVIEW CG B 04-22-25 ISSUED FOR REVIEW SD 0 08-14-25 FINAL CD'S SD 1 09-05-25 FINAL CD'S SD 2 09-23-25 FINAL CD'S SD NOT FOR CONSTRUCTION UNLESS LABELED AS FOR CONSTRUCTION 0 N SI0NgI Q v rn J X * C 90957 ,k s� 9 Z3. ZS �Q 9� CIVIC (3� F pF C A`�F LICENSE NUMBER: C90957 EXPIRATION DATE: MARCH 31, 2026 SICA001875 10087160 2120 1 /2 SOUTH BRISTOL SANTA ANA, CA 92704 SHEET TITLE PLUMBING DIAGRAM SHEET NUMBER P - 1 N.T.S 1 CI -[:OF SANTA ANA Planning and Building Agency u to 6 Ld m x O w IL iJ U V) w U Ld w w w U O w g w x _U 3 x z x H it w x H O w N O U 0 O w In z a 2 0 z PLUMBING DIAGRAM (BETA SECTOR Sector B 400 X x x x X $.45 UuL) X x x x X 277G X x x x X x x X t X J I IX X I x X X x x b •�e+ tit 39Ot► AWS u/ a" woo C= LIZ 700 II" mm tT - J—L- Hatch Plate La L1 t7t ?"on k" mu T�L'T l�T ACu'i � 5 P"w Ilwit tit A" wo mou M DJ 1111111111960m Approved ,A telQ:..T&T t 1452 EDINGER AVENUE, 3RD FLOOR TUSTIN, CA 92780 i� amentum 2 ASH STREET, ST #3000 CONSHOHOCKEN, PA 19428 r c h i t e c t s e n g i n e e r s 5661 COLUMBIA PIKE, SUITE 200 FALLS CHURCH, VA 22041-2868 TEL (703) 671-6000 FAX: (703) 671-6300 REVISIONS REV. DATE DESCRIPTION INRIALS A 01-23-25 ISSUED FOR REVIEW CG B 04-22-25 ISSUED FOR REVIEW SD 0 08-14-25 FINAL CD'S SD 1 09-05-25 FINAL CD'S SD 2 09-23-25 FINAL CD'S SD NOT FOR CONSTRUCTION UNLESS LABELED AS FOR CONSTRUCTION 0 N SI0NgI Q v rn J X * C 90957 ,k s� 9 Z3. ZS �Q 9� CIVIC (3� F pF CA LICENSE NUMBER: C90957 EXPIRATION DATE: MARCH 31, 2026 SICA001875 10087160 2120 1/2 SOUTH BRISTOL SANTA ANA, CA 92704 SHEET TITLE PLUMBING DIAGRAM SHEET NUMBER P-1.1 E CI -[:OF SANTA ANA Planning and Building Agency 0 H _m _ O w 0- V) w U Ld w w w U O r V) g w x _U 3 z x H it w _ H O w N O U 0 O w V) Z w } m n- n- o w a (N Z w U O 0 z O U Z O U LL O Li V) V) Z 0 w z z z O U z O a 0 Z w PLUMBING DIAGRAM (GAMMA SECTOR Sector C* �.a ♦fr.* 046 .., .M x loft Am xx x x x x x/ x x x x x SAS 0 �?. x fi x fix/ x / { x AM"11 , x x x x x 877G x x x x x x x x x x - x x x ;� .K X _ tiiLJ L--' U rjrjwLJ LJ L._1 L.L UE-J l `Y LT. LJL 3 lR 17D[Vi►Mif all 11" "m •.......• SOON SEEM m m ....... .......MEMO mom. G *&Md TOO AM Lit NA Hatch Plate l7L 74000! sM tau �J t" wn &W mu p_ .N 11111111111111011 M DJ Approved AT&T ter�lQ:.. 1452 EDINGER AVENUE, 3RD FLOOR TUSTIN, CA 92780 i� amentum 2 ASH STREET, ST #3000 CONSHOHOCKEN, PA 19428 BC r c h i t e c t s e n g i n e e r s 5661 COLUMBIA PIKE, SUITE 200 FALLS CHURCH, VA 22041-2868 TEL (703) 671-6000 FAX: (703) 671-6300 REVISIONS REV. DATE DESCRIPTION INMALS A 01-23-25 ISSUED FOR REVIEW CG B 04-22-25 ISSUED FOR REVIEW SD 0 08-14-25 FINAL CD'S SD 1 09-05-25 FINAL CD'S SD 2 09-23-25 FINAL CD'S SD NOT FOR CONSTRUCTION UNLESS LABELED AS FOR CONSTRUCTION o� N SI C�ql Q v rn J X * C 90957 ,k s� 9Z39 �Q 9� CIVIC- F pF CA LICENSE NUMBER: C90957 EXPIRATION DATE: MARCH 31, 2026 SICA001875 10087160 2120 1/2 SOUTH BRISTOL SANTA ANA, CA 92704 SHEET TITLE PLUMBING DIAGRAM SHEET NUMBER P-1.2 E BC Architects Engineers, PLC; 5661 Columbia Pike, Suite 200, Falls Church, VA 22041-2868; Tel (703) 671-6000; Fax (703) 671-6300 ANTENNA MOUNT ANALYSIS (Rev. 0 – PASSING) FA Code – 10087160 PTN – 3551A1F849 Site ID – SICA001875 May 8, 2025 Prepared for: Amentum 2 Ash Street, St # 3000 Conshohocken, PA 19428 BC Architects Engineers, PLC; 5661 Columbia Pike, Suite 200, Falls Church, VA 22041-2868; Tel (703) 671-6000; Fax (703) 671-6300 Certification Letter BC Architects Engineers, PLC 5661 Columbia Pike, Suite 200, Falls Church, VA 22041-2868 Tel (703) 671-6000 Fax (703) 671-6300 May 8, 2025 Ms. Linda Renfroe Amentum 2 Ash Street, St # 3000 Conshohocken, PA 19428 RE: FA Code – 10087160 PTN – 3551A1F849 Site ID – SICA001875 Site Address – 2120 ½ South Bristol, Santa Ana, CA 92704 Ms. Renfroe, Pursuant to your request, we have completed the analysis of the existing antenna sector mounts and all associated connections and incidental components for the installation of proposed equipment at the above referenced site, as shown on project documents. AT&T’s proposed scope of work consists of installing (3) panel antennas. The proposed installation will result in a total of (15) panel antennas, (15) RRUs, and (4) DC6s. This is to certify that to the best of my knowledge and professional opinion, the antenna support system components have been analyzed in accordance with the applicable codes and standards, as required by the IBC-2021, ASCE 7-16, and TIA-222-H. Based on the 3-D structural analysis software and our calculations, the existing antenna sector mounts have adequate capacity to support the proposed loads and PASS at 87.2%. If I can be of further assistance, please feel free to contact me. Sincerely, Rama Pranav Kristam, P.E. Principal Member of BC Architects Engineers, PLC Appendix A Summary Site ID & FA Code: SICA001875 & 10087160 Page: 1 PTN: 3551A1F849 Date: May 8, 2025 Address: 2120 ½ South Bristol Designed By: V.K. Santa Ana, CA 92704 Checked By: R.K BC Architects Engineers, PLC 5661 Columbia Pike, Suite 200, Falls Church, VA 22041-2868 Tel (703) 671-6000 Fax (703) 671-6300 The purpose of this calculation package is to examine the adequacy of the existing antenna sector mounts & attachments for support of new appurtenances. The existing antenna sector mounts were analyzed using a 3D model in RISA 3D. It is assumed that the mount connection elements are capable of resisting the loading associated with the full member strength of the antenna mount’s structural members. Proposed Final Appurtenances: Note: This table includes tower-mounted equipment only. Bold letters indicate proposed equipment. Structural Documentation Provided: Previous Mount Analysis POD Group, Inc., dated July 7, 2021 It is assumed that all information provided to BC for this analysis is accurate and, unless otherwise noted, the structure has been maintained in accordance with code standards and is in good condition. Se c t o r ntennas RRUs Ra y c a p Po s i t i o n Make Model RA D ( f t ) Az i m u t h (d e g ) Al p h a 1 CommScope NNH4-65C-R6-V3 57 100 4449 B5/B12 8843 B2/B66A DC6 2 Ericsson AIR6419 B77G AIR6449 B77D 59.83 56.5 - 3 Kathrein 80010966 57 4478 B14 4 Kathrein 80010866 57 RRUS-32 B30 RRUS-E2 B29 (Ground) Be t a 5 CommScope NNH4-65C-R6-V3 57 220 4449 B5/B12 8843 B2/B66A (2)DC6 6 Ericsson AIR6419 B77G AIR6449 B77D 59.83 56.5 - 7 Kathrein 80010966 57 4478 B14 8 Kathrein 80010866 57 RRUS-32 B30 RRUS-E2 B29 (Ground) Ga m m a 9 CommScope NNH4-65C-R6-V3 57 340 4449 B5/B12 8843 B2/B66A DC6 10 Ericsson AIR6419 B77G AIR6449 B77D 59.83 56.5 - 11 Kathrein 80010966 57 4478 B14 12 Kathrein 80010866 57 RRUS-32 B30 RRUS-E2 B29 (Ground) Site ID & FA Code: SICA001875 & 10087160 Page: 2 PTN: 3551A1F849 Date: May 8, 2025 Address: 2120 ½ South Bristol Designed By: V.K. Santa Ana, CA 92704 Checked By: R.K BC Architects Engineers, PLC 5661 Columbia Pike, Suite 200, Falls Church, VA 22041-2868 Tel (703) 671-6000 Fax (703) 671-6300 Member Capacity Summary: Component Peak Usage Result Standoff Diagonal 87.2% Pass Mount Pipe 38.0% Pass Back Plate 29.5% Pass Standoff Plate 21.7% Pass Face Horizontal 20.6% Pass Kicker 20.2% Pass Support Arm 20.0% Pass Note: Capacities up to 105% are considered acceptable based on analysis methods used. Assumptions & Considerations: This analysis considers only the theoretical capacity of structural components, and it is not a condition assessment of the mount or its attachments. The validity of the analysis is dependent on the accuracy of structural information supplied by others. If any provided information is revised after completion of this analysis, BC should be notified immediately to revise results. 1) Wind forces are considered from 360° in relation to the mounting system and applied at 30° increments using load combination factors in accordance with TIA-222-H section 2.6.11.2. 2) Antenna azimuths are considered perpendicular to antenna mount face unless a variation exists greater than 30°. 3) Appurtenance EPA’s are derived using TIA-222-H section 2.6.11.1. 4) Seismic forces are applied using load combination factors in accordance with TIA-222-H section 2.7. 5) All appurtenance dimensions and weights are accurate as supplied, as stated in the calculations. If no data is available, appurtenance physical characteristics are based off manufacturer specifications. 6) Upon identical mounting systems, the most critical sector has been analyzed. 7) TIA-222-H is considered to take precedent over all listed state and local building codes, unless otherwise stated. Appendix B Calculations Wind Speed, Basic (mph) 95 Annex B Wind Speed, with Ice (mph) 30 Annex B Exposure C Sec. 2.6.5 Wind Direction Factor 0.95 Sec. 16.6 No Ice 24.89 Gust Effect Factor 1 Sec. 16.6 Risk Category 2 Table 2-1 Centerline AGL (From RFDS) 59.8 ft (The maximum recorded centerline AGL has been used for the purpose of wind/ice calculations) Site Elevation 48.0 ft Crest Height 0 ft Topographic Category 1 Sec. 2.6.6.2.2 Ground Elevation Factor 1.00 Sec. 2.6.8 Shielding Factor 0.9 Sec. 16.6 Appurtenance Name Height (in) Width (in) Depth (in)Weight (lbs.)Ca Front EPAn (ft2) Fa Front (lbs.)Ca Side EPAt (ft2) Fa Side (lbs.) CommScope NNH4-65C-R6-V3 96 19.6 7.8 102 * 9.700 241.4 * 3.300 82.1 Ericsson AIR6419 B77G (STACKED) 28.0 15.7 6.7 66.1 * 3.230 80.4 * 1.100 27.4 Ericsson AIR6449 B77D (STACKED) 31.0 15.9 8.7 83.6 1.200 3.697 92.0 1.247 2.102 52.3 Kathrein 80010966 96.0 20.0 6.9 114.0 1.302 15.624 388.9 1.631 6.751 168.0 Kathrein 80010866 96.0 14.8 6.7 77.0 1.377 12.227 304.3 1.645 6.611 164.5 Ericsson RRUS 4449 B5/B12 17.9 13.2 9.4 71.0 1.200 1.772 44.1 1.200 1.262 31.4 Ericsson 8843 B2/B66A 15.0 13.2 11.1 75.0 1.200 1.480 36.8 1.200 1.245 31.0 Ericsson RRUS 4478 B14 16.5 13.4 7.7 59.9 1.200 1.658 41.3 1.200 0.953 23.7 Ericsso RRUS-32 B30 26.7 12.1 6.7 60.0 1.200 2.423 60.3 1.266 1.415 35.2 Raycap DC6-48-60-18-8F 31.3 11.0 11.0 32.8 0.700 1.506 37.5 0.700 1.506 37.5 Member Width (in) Shape Ca (max)Fa (lbs./ft) Pipe 2.88"x0.276" 2.88 Round 1.20 6.5 PIPE_2.0 2.38 Round 1.20 5.3 PIPE_3.0 3.50 Round 1.20 7.8 SR 3/4 0.75 Round 1.20 1.7 PL 3X5/8 0.63 Flat 2.00 2.3 PL 4X1/2 0.50 Flat 2.00 1.9 *Antenna Wind EPA based on Wind Tunnel Test. Wind Load Calculation Per TIA-222-H qz(psf) Appurtenance Wind Member Wind Date: 05-08-2025 Designed By: V.K. Site ID SICA001875 FA Code 10087160 Checked By: R.K. 1 1.032 2 1 0.462 0.516 0.045408 0.045408 0.516 0.516 0.206 Design Spectral Response Parameter, SDS Section 2.7.5 Seismic Load Parameter Calculation Reference Code: TIA-222-H Amplification Factor, AS Section 16.7 Response Modification Factor, R Section 16.7 Seismic Importance Factor, I Table 2-3 MCER Ground Motion, S1 Section 2.7.4 Vertical Seismic Load Effect Factor = AS0.2(SDS)Section 2.7.6 Seismic Response Coefficient, CS = SDS I/R Section 2.7.7.1CS min = 0.044SDSI ≥ 0.03 CS min = 0.8S1/(R/I), if S1 ≥0.6 Cs,used Lateral Seismic Load Effect Factor= ASCs,used Section 2.7.6 Appendix C Software Output BC Architects Engineers, PLC Vamshi Krishna SICA001875 Antenna Mount Analysis Render May 8, 2025 at 4:16 PM SICA001875 - 10087160.r3d Y XZ Envelope Only Solution BC Architects Engineers, PLC Vamshi Krishna SICA001875 Antenna Mount Analysis Shapes May 8, 2025 at 4:17 PM SICA001875 - 10087160.r3d Pipe 2.88"x0.276" Pipe 2.88"x0.276" Pi p e 2 . 8 8 " x 0 . 1 2 0 " Pi p e 2 . 8 8 " x 0 . 1 2 0 " Pi p e 2 . 8 8 " x 0 . 1 2 0 " Pi p e 2 . 8 8 " x 0 . 1 2 0 " PL 4X1/2 PL 4X1/2PIPE_2.0 PL 3X5/8PL 4X1/2 PL 4X1/2PIPE_2.0 PL 4X1/2 PL 4X1/2 PL 4X1/2 PL 4X1/2 PIPE_2.0 PIPE_2.0 SR 3 / 4 SR 3 / 4 SR 3/4SR 3/4 SR 3/4 SR 3/4 PI P E _ 3 . 0 PL 3X5/8 Pipe 2.88"x0.120" Pipe 2.88"x0.120" Y XZ Envelope Only Solution BC Architects Engineers, PLC Vamshi Krishna SICA001875 Antenna Mount Analysis Labels May 8, 2025 at 4:17 PM SICA001875 - 10087160.r3d M1 M6 M1 1 M1 2 M1 3 M1 4 M19 M20M21 M22M23M24M25 M26 M27 M28 M29 M30 M31 M3 2 M3 3 M34M35 M36 M37 M4 0 M43 M46 M47 Y XZ Envelope Only Solution BC Architects Engineers, PLC Vamshi Krishna SICA001875 Antenna Mount Analysis Equipment May 8, 2025 at 4:20 PM SICA001875 - 10087160.r3d Y XZ Envelope Only Solution Per Sector: (1) CommScope NNH-65C-R6-V3 (3 total) Per Sector: (1) Ericsson 8843 B2/B66A (3 total) Per Sector: (1) Ericsson AIR6419 B77G (3 total) (1) Ericsson AIR6449 B77D (3 total) Per Sector: (1) Ericsson 4449 B5/B12 (3 total) Per Sector: (1) Kathrein 80010966 (3 total) Per Sector: (1) Ericsson 4478 B14 (3 total) Per Sector: (1) Kathrein 80010866 (3 total) Per Sector: (1) Ericsson RRUS-32 B30 (3 total) (2) Raycap DC6s BC Architects Engineers, PLC Vamshi Krishna SICA001875 Antenna Mount Analysis Dead Loads May 8, 2025 at 4:18 PM SICA001875 - 10087160.r3d -33.1lb -57lb -38.5lb -51lb -51lb -33.1lb -41.8lb -41.8lb -57lb -38.5lb -32.8lb -32.8lb -75lb -71lb -59.9lb -60lb Y XZ Loads: BLC 1, DL Envelope Only Solution BC Architects Engineers, PLC Vamshi Krishna SICA001875 Antenna Mount Analysis WLX May 8, 2025 at 4:18 PM SICA001875 - 10087160.r3d 6.5lb/ft 6.5lb/ft 6.5lb/ft 6.5lb/ft 1.42lb/ft 1.42lb/ft3.961lb/ft 1.42lb/ft 1.42lb/ft3.961lb/ft 1.42lb/ft 1.42lb/ft 1.42lb/ft 1.42lb/ft 3.961lb/ft 3.961lb/ft 1.7lb/ft 1.7lb/ft1.488lb/ft 1.488lb/ft 1.488lb/ft 1.488lb/ft 7.8lb/ft6.401lb/ft 6.108lb/ft 13.7lb 84lb 82.3lb 41.1lb 41.1lb 13.7lb 26.2lb 26.2lb 84lb 82.3lb 37.5lb 37.5lb 31lb 31.4lb 23.7lb 35.2lb Y XZ Loads: BLC 2, WLX Envelope Only Solution BC Architects Engineers, PLC Vamshi Krishna SICA001875 Antenna Mount Analysis WLZ May 8, 2025 at 4:18 PM SICA001875 - 10087160.r3d 6.5lb/ft 6.5lb/ft 6.5lb/ft 6.5lb/ft 6.5lb/ft 6.5lb/ft 1.263lb/ft 1.263lb/ft3.522lb/ft 2.3lb/ft1.263lb/ft 1.263lb/ft3.522lb/ft 1.263lb/ft 1.263lb/ft 1.263lb/ft 1.263lb/ft 3.522lb/ft 3.522lb/ft 1.7lb/ft 1.7lb/ft1.427lb/ft 1.427lb/ft 1.427lb/ft 1.427lb/ft 7.8lb/ft 2.3lb/ft 1.129lb/ft 2.223lb/ft 40.2lb 194.4lb 152.2lb 120.7lb 120.7lb 40.2lb 46lb 46lb 194.4lb 152.2lb 37.5lb 37.5lb 36.8lb 44.1lb 41.3lb 60.3lb Y XZ Loads: BLC 3, WLZ Envelope Only Solution BC Architects Engineers, PLC Vamshi Krishna SICA001875 Antenna Mount Analysis LLm(1) May 8, 2025 at 4:19 PM SICA001875 - 10087160.r3d -500lb Y XZ Loads: BLC 4, Lm(1) Envelope Only Solution BC Architects Engineers, PLC Vamshi Krishna SICA001875 Antenna Mount Analysis LLv(1) May 8, 2025 at 4:19 PM SICA001875 - 10087160.r3d -250lb Y XZ Loads: BLC 10, Lv(3) Envelope Only Solution Company : BC Architects Engineers, PLC May 8, 2025 4:29 PMDesigner : Vamshi Krishna Job Number : SICA001875 Checked By: Rama Kristam Model Name : Antenna Mount Analysis (Global) Model Settings Display Sections for Member Calcs Max Internal Sections for Member Calcs Include Shear Deformation? Increase Nailing Capacity for Wind? Include Warping? Trans Load Btwn Intersecting Wood Wall? Area Load Mesh (in^2) Merge Tolerance (in) P-Delta Analysis Tolerance Include P-Delta for Walls? Automatically Iterate Stiffness for Walls? Max Iterations for Wall Stiffness Gravity Acceleration (in/sec^2) Wall Mesh Size (in) Eigensolution Convergence Tol. (1.E-) Vertical Axis Global Member Orientation Plane Static Solver Dynamic Solver 5 97 Yes Yes Yes Yes 144 .12 0.50% Yes Yes 3 386.4 24 4 Y XZ Sparse Accelerated Accelerated Solver Hot Rolled Steel Code Adjust Stiffness? RISAConnection Code Cold Formed Steel Code Wood Code Wood Temperature Concrete Code Masonry Code Aluminum Code Stainless Steel Code Adjust Stiffness? AISC 15th(360-16): LRFD Yes(Iterative) AISC 15th(360-16): LRFD AISI S100-10: LRFD < 100F TMS 402-16: ASD - Building AISC 14th(360-10): ASD Yes(Iterative) RISA-3D Version 17.0.4 Page 1 [C:\...\...\...\...\...\...\Jacobs\Southern California\10087160 - WSLOS0068563\MA Rev 0\SICA001875 - 10087160.r3d] Company : BC Architects Engineers, PLC May 8, 2025 4:29 PMDesigner : Vamshi Krishna Job Number : SICA001875 Checked By: Rama Kristam Model Name : Antenna Mount Analysis (Global) Model Settings, Continued Number of Shear Regions Region Spacing Increment (in) Biaxial Column Method Parme Beta Factor (PCA) Concrete Stress Block Use Cracked Sections? Use Cracked Sections Slab? Bad Framing Warnings? Unused Force Warnings? Min 1 Bar Diam. Spacing? Concrete Rebar Set Min % Steel for Column Max % Steel for Column 4 4 Exact Integration .65 Rectangular Yes Yes No Yes Yes REBAR_SET_ASTMA615 1 8 Seismic Code Seismic Base Elevation (in) Add Base Weight? Ct X Ct Z T X (sec) T Z (sec) R X R Z Ct Exp. X Ct Exp. Z SD1 SDS S1 TL (sec) Risk Cat Drift Cat ASCE 7-16 Not Entered Yes .02 .02 Not Entered Not Entered 3 3 .75 .75 1 1 1 5 I or II Other Om Z Om X Cd Z Cd X Rho Z Rho X 1 1 4 4 1 1 RISA-3D Version 17.0.4 Page 2 [C:\...\...\...\...\...\...\Jacobs\Southern California\10087160 - WSLOS0068563\MA Rev 0\SICA001875 - 10087160.r3d] Company : BC Architects Engineers, PLC May 8, 2025 4:29 PMDesigner : Vamshi Krishna Job Number : SICA001875 Checked By: Rama Kristam Model Name : Antenna Mount Analysis Hot Rolled Steel Properties Label E [ksi] G [ksi] Nu Therm (/1E5 F) Density[k/ft^3] Yield[ksi] Ry Fu[ksi] Rt 1 A992 29000 11154 .3 .65 .49 50 1.1 65 1.1 2 A36 Gr.36 29000 11154 .3 .65 .49 36 1.5 58 1.2 3 A572 Gr.50 29000 11154 .3 .65 .49 50 1.1 65 1.1 4 A500 Gr.B RND 29000 11154 .3 .65 .527 42 1.4 58 1.3 5 A500 Gr.B RECT 29000 11154 .3 .65 .527 46 1.4 58 1.3 6 A500 Gr.C RND 29000 11154 .3 .65 .527 46 1.4 62 1.3 7 A500 Gr.C RECT 29000 11154 .3 .65 .527 50 1.4 62 1.3 8 A53 Gr.B 29000 11154 .3 .65 .49 35 1.6 60 1.2 9 A1085 29000 11154 .3 .65 .49 50 1.4 65 1.3 10 A913 Gr.65 29000 11154 .3 .65 .49 65 1.1 80 1.1 11 A500 GR. C 29000 11154 .3 .65 .49 36 1.5 58 1.2 12 A529 Gr. 50 29000 11154 .3 .65 .49 36 1.5 58 1.2 Hot Rolled Steel Section Sets Label Shape Type Design List Material Design Rules A [in2] Iyy [in4] Izz [in4] J [in4] 1 Face Horizontal Pipe 2.88"x0.276"Beam Pipe A500 GR. C Typical 2.258 1.935 1.935 3.871 2 Mount Pipe Pipe 2.88"x0.120"Column Pipe A500 GR. C Typical 1.04 .993 .993 1.985 3 Back Plate PL 3X5/8 Beam RECT A572 Gr.50 Typical 2.5 .081 3.333 .293 4 Standoff Diagonal SR 3/4 Beam BAR A529 Gr. 50 Typical .442 .016 .016 .031 5 Kicker PIPE_2.0 Beam Pipe A500 GR. C Typical 1.02 .627 .627 1.25 6 Standoff Plate PL 4X1/2 Beam RECT A572 Gr.50 Typical 2 .042 2.667 .154 7 Support Arm PIPE_3.0 Column Pipe A500 GR. C Typical 2.07 2.85 2.85 5.69 8 Tie Back Pipe 2.88"x0.120"Beam Pipe A500 GR. C Typical 1.04 .993 .993 1.985 9 Standoff Vertical SR 3/4 Column BAR A529 Gr. 50 Typical .442 .016 .016 .031 Hot Rolled Steel Design Parameters Label Shape Length[in] Lbyy[in] Lbzz[in] Lcomp top[in] Lcomp bot[in] L-torque[... Kyy Kzz Cb Function 1 M1 Face Horizontal 150 63 63 Lbyy Lateral 2 M6 Face Horizontal 150 63 63 Lbyy Lateral 3 M11 Mount Pipe 120 Lbyy Lateral 4 M12 Mount Pipe 120 Lbyy Lateral 5 M13 Mount Pipe 120 Lbyy Lateral 6 M14 Mount Pipe 120 Lbyy Lateral 7 M19 Standoff Plate 2.004 Lbyy Lateral 8 M20 Standoff Plate 2.013 Lbyy Lateral 9 M21 Kicker 37.368 Lbyy 2.1 2.1 Lateral RISA-3D Version 17.0.4 Page 3 [C:\...\...\...\...\...\...\Jacobs\Southern California\10087160 - WSLOS0068563\MA Rev 0\SICA001875 - 10087160.r3d] Company : BC Architects Engineers, PLC May 8, 2025 4:29 PMDesigner : Vamshi Krishna Job Number : SICA001875 Checked By: Rama Kristam Model Name : Antenna Mount Analysis Hot Rolled Steel Design Parameters (Continued) Label Shape Length[in] Lbyy[in] Lbzz[in] Lcomp top[in] Lcomp bot[in] L-torque[... Kyy Kzz Cb Function 10 M22 Back Plate 8 Lbyy Lateral 11 M23 Standoff Plate 2.004 Lbyy Lateral 12 M24 Standoff Plate 2.013 Lbyy Lateral 13 M25 Kicker 37.368 Lbyy 2.1 2.1 Lateral 14 M26 Standoff Plate 2.004 Lbyy Lateral 15 M27 Standoff Plate 2.004 Lbyy Lateral 16 M28 Standoff Plate 2.013 Lbyy Lateral 17 M29 Standoff Plate 2.013 Lbyy Lateral 18 M30 Kicker 37.368 Lbyy 2.1 2.1 Lateral 19 M31 Kicker 37.368 Lbyy 2.1 2.1 Lateral 20 M32 Standoff Vertical 33 Lbyy Lateral 21 M33 Standoff Vertical 33 Lbyy Lateral 22 M34 Standoff Diagonal 48.081 Lbyy Lateral 23 M35 Standoff Diagonal 48.081 Lbyy Lateral 24 M36 Standoff Diagonal 48.081 Lbyy Lateral 25 M37 Standoff Diagonal 48.081 Lbyy Lateral 26 M40 Support Arm 48 Lbyy Lateral 27 M43 Back Plate 8 Lbyy Lateral 28 M46 Tie Back 60 Lbyy Lateral 29 M47 Tie Back 60 Lbyy Lateral Joint Loads and Enforced Displacements (BLC 1 : DL) Joint Label L,D,M Direction Magnitude[(lb,k-ft), (in,rad), (lb*s^2/in, lb*s^2*in)] 1 N74 L Y -51 2 N75 L Y -51 3 N84 L Y -71 4 N83 L Y -75 5 N71 L Y -33.1 6 N76 L Y -33.1 7 N77 L Y -41.8 8 N78 L Y -41.8 9 N72 L Y -57 10 N79 L Y -57 11 N85 L Y -59.9 12 N73 L Y -38.5 13 N80 L Y -38.5 14 N86 L Y -60 15 N81 L Y -32.8 RISA-3D Version 17.0.4 Page 4 [C:\...\...\...\...\...\...\Jacobs\Southern California\10087160 - WSLOS0068563\MA Rev 0\SICA001875 - 10087160.r3d] Company : BC Architects Engineers, PLC May 8, 2025 4:29 PMDesigner : Vamshi Krishna Job Number : SICA001875 Checked By: Rama Kristam Model Name : Antenna Mount Analysis Joint Loads and Enforced Displacements (BLC 1 : DL) (Continued) Joint Label L,D,M Direction Magnitude[(lb,k-ft), (in,rad), (lb*s^2/in, lb*s^2*in)] 16 N82 L Y -32.8 Joint Loads and Enforced Displacements (BLC 2 : WLX) Joint Label L,D,M Direction Magnitude[(lb,k-ft), (in,rad), (lb*s^2/in, lb*s^2*in)] 1 N74 L X 41.1 2 N75 L X 41.1 3 N84 L X 31.4 4 N83 L X 31 5 N71 L X 13.7 6 N76 L X 13.7 7 N77 L X 26.2 8 N78 L X 26.2 9 N72 L X 84 10 N79 L X 84 11 N85 L X 23.7 12 N73 L X 82.3 13 N80 L X 82.3 14 N86 L X 35.2 15 N81 L X 37.5 16 N82 L X 37.5 Joint Loads and Enforced Displacements (BLC 3 : WLZ) Joint Label L,D,M Direction Magnitude[(lb,k-ft), (in,rad), (lb*s^2/in, lb*s^2*in)] 1 N74 L Z 120.7 2 N75 L Z 120.7 3 N84 L Z 44.1 4 N83 L Z 36.8 5 N71 L Z 40.2 6 N76 L Z 40.2 7 N77 L Z 46 8 N78 L Z 46 9 N72 L Z 194.4 10 N79 L Z 194.4 11 N85 L Z 41.3 12 N73 L Z 152.2 13 N80 L Z 152.2 14 N86 L Z 60.3 15 N81 L Z 37.5 16 N82 L Z 37.5 RISA-3D Version 17.0.4 Page 5 [C:\...\...\...\...\...\...\Jacobs\Southern California\10087160 - WSLOS0068563\MA Rev 0\SICA001875 - 10087160.r3d] Company : BC Architects Engineers, PLC May 8, 2025 4:29 PMDesigner : Vamshi Krishna Job Number : SICA001875 Checked By: Rama Kristam Model Name : Antenna Mount Analysis Joint Loads and Enforced Displacements (BLC 4 : Lm(1)) Joint Label L,D,M Direction Magnitude[(lb,k-ft), (in,rad), (lb*s^2/in, lb*s^2*in)] 1 N11 L Y -500 Joint Loads and Enforced Displacements (BLC 5 : Lm(2)) Joint Label L,D,M Direction Magnitude[(lb,k-ft), (in,rad), (lb*s^2/in, lb*s^2*in)] 1 N8 L Y -500 Joint Loads and Enforced Displacements (BLC 6 : Lm(3)) Joint Label L,D,M Direction Magnitude[(lb,k-ft), (in,rad), (lb*s^2/in, lb*s^2*in)] 1 N9 L Y -500 Joint Loads and Enforced Displacements (BLC 7 : Lm(4)) Joint Label L,D,M Direction Magnitude[(lb,k-ft), (in,rad), (lb*s^2/in, lb*s^2*in)] 1 N10 L Y -500 Joint Loads and Enforced Displacements (BLC 8 : Lv(1)) Joint Label L,D,M Direction Magnitude[(lb,k-ft), (in,rad), (lb*s^2/in, lb*s^2*in)] 1 N2 L Y -250 Joint Loads and Enforced Displacements (BLC 9 : Lv(2)) Joint Label L,D,M Direction Magnitude[(lb,k-ft), (in,rad), (lb*s^2/in, lb*s^2*in)] 1 N13 L Y -250 Joint Loads and Enforced Displacements (BLC 10 : Lv(3)) Joint Label L,D,M Direction Magnitude[(lb,k-ft), (in,rad), (lb*s^2/in, lb*s^2*in)] 1 N1 L Y -250 Joint Loads and Enforced Displacements (BLC 11 : Lv(4)) Joint Label L,D,M Direction Magnitude[(lb,k-ft), (in,rad), (lb*s^2/in, lb*s^2*in)] 1 N12 L Y -250 Joint Loads and Enforced Displacements (BLC 14 : Ev) Joint Label L,D,M Direction Magnitude[(lb,k-ft), (in,rad), (lb*s^2/in, lb*s^2*in)] 1 N74 L Y -51 2 N75 L Y -51 3 N84 L Y -71 4 N83 L Y -75 RISA-3D Version 17.0.4 Page 6 [C:\...\...\...\...\...\...\Jacobs\Southern California\10087160 - WSLOS0068563\MA Rev 0\SICA001875 - 10087160.r3d] Company : BC Architects Engineers, PLC May 8, 2025 4:29 PMDesigner : Vamshi Krishna Job Number : SICA001875 Checked By: Rama Kristam Model Name : Antenna Mount Analysis Joint Loads and Enforced Displacements (BLC 14 : Ev) (Continued) Joint Label L,D,M Direction Magnitude[(lb,k-ft), (in,rad), (lb*s^2/in, lb*s^2*in)] 5 N71 L Y -33.1 6 N76 L Y -33.1 7 N77 L Y -41.8 8 N78 L Y -41.8 9 N72 L Y -57 10 N79 L Y -57 11 N85 L Y -59.9 12 N73 L Y -38.5 13 N80 L Y -38.5 14 N86 L Y -60 15 N81 L Y -32.8 16 N82 L Y -32.8 Joint Loads and Enforced Displacements (BLC 15 : Ehx) Joint Label L,D,M Direction Magnitude[(lb,k-ft), (in,rad), (lb*s^2/in, lb*s^2*in)] 1 N74 L X -51 2 N75 L X -51 3 N84 L X -71 4 N83 L X -75 5 N71 L X -33.1 6 N76 L X -33.1 7 N77 L X -41.8 8 N78 L X -41.8 9 N72 L X -57 10 N79 L X -57 11 N85 L X -59.9 12 N73 L X -38.5 13 N80 L X -38.5 14 N86 L X -60 15 N81 L X -32.8 16 N82 L X -32.8 Joint Loads and Enforced Displacements (BLC 16 : Ehz) Joint Label L,D,M Direction Magnitude[(lb,k-ft), (in,rad), (lb*s^2/in, lb*s^2*in)] 1 N74 L Z -51 2 N75 L Z -51 3 N84 L Z -71 4 N83 L Z -75 5 N71 L Z -33.1 RISA-3D Version 17.0.4 Page 7 [C:\...\...\...\...\...\...\Jacobs\Southern California\10087160 - WSLOS0068563\MA Rev 0\SICA001875 - 10087160.r3d] Company : BC Architects Engineers, PLC May 8, 2025 4:29 PMDesigner : Vamshi Krishna Job Number : SICA001875 Checked By: Rama Kristam Model Name : Antenna Mount Analysis Joint Loads and Enforced Displacements (BLC 16 : Ehz) (Continued) Joint Label L,D,M Direction Magnitude[(lb,k-ft), (in,rad), (lb*s^2/in, lb*s^2*in)] 6 N76 L Z -33.1 7 N77 L Z -41.8 8 N78 L Z -41.8 9 N72 L Z -57 10 N79 L Z -57 11 N85 L Z -59.9 12 N73 L Z -38.5 13 N80 L Z -38.5 14 N86 L Z -60 15 N81 L Z -32.8 16 N82 L Z -32.8 Member Distributed Loads (BLC 2 : WLX) Member Label Direction Start Magnitude[lb/ft,F,psf] End Magnitude[lb/ft,F,psf] Start Location[in,%] End Location[in,%] 1 M1 PX 6.5 6.5 0 0 2 M6 PX 6.5 6.5 0 0 3 M11 PX 6.5 6.5 0 0 4 M12 PX 6.5 6.5 0 0 5 M13 PX 6.5 6.5 0 0 6 M14 PX 6.5 6.5 0 0 7 M46 PX 6.5 6.5 0 0 8 M47 PX 6.5 6.5 0 0 9 M21 PX 5.3 5.3 0 0 10 M25 PX 5.3 5.3 0 0 11 M30 PX 5.3 5.3 0 0 12 M31 PX 5.3 5.3 0 0 13 M40 PX 7.8 7.8 0 0 14 M32 PX 1.7 1.7 0 0 15 M33 PX 1.7 1.7 0 0 16 M34 PX 1.7 1.7 0 0 17 M35 PX 1.7 1.7 0 0 18 M36 PX 1.7 1.7 0 0 19 M37 PX 1.7 1.7 0 0 20 M22 PX 2.3 2.3 0 0 21 M43 PX 2.3 2.3 0 0 22 M19 PX 1.9 1.9 0 0 23 M20 PX 1.9 1.9 0 0 24 M23 PX 1.9 1.9 0 0 RISA-3D Version 17.0.4 Page 8 [C:\...\...\...\...\...\...\Jacobs\Southern California\10087160 - WSLOS0068563\MA Rev 0\SICA001875 - 10087160.r3d] Company : BC Architects Engineers, PLC May 8, 2025 4:29 PMDesigner : Vamshi Krishna Job Number : SICA001875 Checked By: Rama Kristam Model Name : Antenna Mount Analysis Member Distributed Loads (BLC 2 : WLX) (Continued) Member Label Direction Start Magnitude[lb/ft,F,psf] End Magnitude[lb/ft,F,psf] Start Location[in,%] End Location[in,%] 25 M24 PX 1.9 1.9 0 0 26 M26 PX 1.9 1.9 0 0 27 M27 PX 1.9 1.9 0 0 28 M28 PX 1.9 1.9 0 0 29 M29 PX 1.9 1.9 0 0 Member Distributed Loads (BLC 3 : WLZ) Member Label Direction Start Magnitude[lb/ft,F,psf] End Magnitude[lb/ft,F,psf] Start Location[in,%] End Location[in,%] 1 M1 PZ 6.5 6.5 0 0 2 M6 PZ 6.5 6.5 0 0 3 M11 PZ 6.5 6.5 0 0 4 M12 PZ 6.5 6.5 0 0 5 M13 PZ 6.5 6.5 0 0 6 M14 PZ 6.5 6.5 0 0 7 M46 PZ 6.5 6.5 0 0 8 M47 PZ 6.5 6.5 0 0 9 M21 PZ 5.3 5.3 0 0 10 M25 PZ 5.3 5.3 0 0 11 M30 PZ 5.3 5.3 0 0 12 M31 PZ 5.3 5.3 0 0 13 M40 PZ 7.8 7.8 0 0 14 M32 PZ 1.7 1.7 0 0 15 M33 PZ 1.7 1.7 0 0 16 M34 PZ 1.7 1.7 0 0 17 M35 PZ 1.7 1.7 0 0 18 M36 PZ 1.7 1.7 0 0 19 M37 PZ 1.7 1.7 0 0 20 M22 PZ 2.3 2.3 0 0 21 M43 PZ 2.3 2.3 0 0 22 M19 PZ 1.9 1.9 0 0 23 M20 PZ 1.9 1.9 0 0 24 M23 PZ 1.9 1.9 0 0 25 M24 PZ 1.9 1.9 0 0 26 M26 PZ 1.9 1.9 0 0 27 M27 PZ 1.9 1.9 0 0 28 M28 PZ 1.9 1.9 0 0 29 M29 PZ 1.9 1.9 0 0 RISA-3D Version 17.0.4 Page 9 [C:\...\...\...\...\...\...\Jacobs\Southern California\10087160 - WSLOS0068563\MA Rev 0\SICA001875 - 10087160.r3d] Company : BC Architects Engineers, PLC May 8, 2025 4:29 PMDesigner : Vamshi Krishna Job Number : SICA001875 Checked By: Rama Kristam Model Name : Antenna Mount Analysis Member Point Loads (BLC 12 : Lv(5)) Member Label Direction Magnitude[lb,k-ft] Location[in,%] 1 M1 Y -250 %50 Member Point Loads (BLC 13 : Lv(6)) Member Label Direction Magnitude[lb,k-ft] Location[in,%] 1 M6 Y -250 %50 Basic Load Cases BLC Description Category X Gravity Y Gravity Z Gravity Joint Point Distributed Area(Member) Surface(Plate/... 1 DL DL -1 16 2 WLX WLX 16 29 3 WLZ WLZ 16 29 4 Lm(1)None 1 5 Lm(2)None 1 6 Lm(3)None 1 7 Lm(4)None 1 8 Lv(1)None 1 9 Lv(2)None 1 10 Lv(3)None 1 11 Lv(4)None 1 12 Lv(5)None 1 13 Lv(6)None 1 14 Ev ELY -1 16 15 Ehx ELX -1 16 16 Ehz ELZ -1 16 Load Combinations Description SolvePD... SR... BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor 1 1.4D Yes Y DL 1.4 2 1.2D + 1.0W AZI 000 Yes Y DL 1.2 WLZ 1 WLX 3 1.2D + 1.0W AZI 030 Yes Y DL 1.2 WLZ .866 WLX .5 4 1.2D + 1.0W AZI 060 Yes Y DL 1.2 WLZ .5 WLX .866 5 1.2D + 1.0W AZI 090 Yes Y DL 1.2 WLZ WLX 1 6 1.2D + 1.0W AZI 120 Yes Y DL 1.2 WLZ -.5 WLX .866 7 1.2D + 1.0W AZI 150 Yes Y DL 1.2 WLZ -.866 WLX .5 8 1.2D + 1.0W AZI 180 Yes Y DL 1.2 WLZ -1 WLX 9 1.2D + 1.0W AZI 210 Yes Y DL 1.2 WLZ -.866 WLX -.5 RISA-3D Version 17.0.4 Page 10 [C:\...\...\...\...\...\...\Jacobs\Southern California\10087160 - WSLOS0068563\MA Rev 0\SICA001875 - 10087160.r3d] Company : BC Architects Engineers, PLC May 8, 2025 4:29 PMDesigner : Vamshi Krishna Job Number : SICA001875 Checked By: Rama Kristam Model Name : Antenna Mount Analysis Load Combinations (Continued) Description SolvePD... SR... BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor 10 1.2D + 1.0W AZI 240 Yes Y DL 1.2 WLZ -.5 WLX -.866 11 1.2D + 1.0W AZI 270 Yes Y DL 1.2 WLZ WLX -1 12 1.2D + 1.0W AZI 300 Yes Y DL 1.2 WLZ .5 WLX -.866 13 1.2D + 1.0W AZI 330 Yes Y DL 1.2 WLZ .866 WLX -.5 14 1.2D + 1.5Lm(1) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ .1 WLX 4 1.5 15 1.2D + 1.5Lm(1) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ .086 WLX .05 4 1.5 16 1.2D + 1.5Lm(1) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ .05 WLX .086 4 1.5 17 1.2D + 1.5Lm(1) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ WLX .1 4 1.5 18 1.2D + 1.5Lm(1) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ -.05 WLX .086 4 1.5 19 1.2D + 1.5Lm(1) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ -.086 WLX .05 4 1.5 20 1.2D + 1.5Lm(1) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ -.1 WLX 4 1.5 21 1.2D + 1.5Lm(1) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ -.086 WLX -.05 4 1.5 22 1.2D + 1.5Lm(1) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ -.05 WLX -.086 4 1.5 23 1.2D + 1.5Lm(1) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ WLX -.1 4 1.5 24 1.2D + 1.5Lm(1) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ .05 WLX -.086 4 1.5 25 1.2D + 1.5Lm(1) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ .086 WLX -.05 4 1.5 26 1.2D + 1.5Lm(2) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ .1 WLX 5 1.5 27 1.2D + 1.5Lm(2) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ .086 WLX .05 5 1.5 28 1.2D + 1.5Lm(2) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ .05 WLX .086 5 1.5 29 1.2D + 1.5Lm(2) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ WLX .1 5 1.5 30 1.2D + 1.5Lm(2) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ -.05 WLX .086 5 1.5 31 1.2D + 1.5Lm(2) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ -.086 WLX .05 5 1.5 32 1.2D + 1.5Lm(2) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ -.1 WLX 5 1.5 33 1.2D + 1.5Lm(2) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ -.086 WLX -.05 5 1.5 34 1.2D + 1.5Lm(2) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ -.05 WLX -.086 5 1.5 35 1.2D + 1.5Lm(2) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ WLX -.1 5 1.5 36 1.2D + 1.5Lm(2) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ .05 WLX -.086 5 1.5 37 1.2D + 1.5Lm(2) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ .086 WLX -.05 5 1.5 38 1.2D + 1.5Lm(3) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ .1 WLX 6 1.5 39 1.2D + 1.5Lm(3) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ .086 WLX .05 6 1.5 40 1.2D + 1.5Lm(3) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ .05 WLX .086 6 1.5 41 1.2D + 1.5Lm(3) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ WLX .1 6 1.5 42 1.2D + 1.5Lm(3) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ -.05 WLX .086 6 1.5 43 1.2D + 1.5Lm(3) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ -.086 WLX .05 6 1.5 44 1.2D + 1.5Lm(3) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ -.1 WLX 6 1.5 45 1.2D + 1.5Lm(3) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ -.086 WLX -.05 6 1.5 46 1.2D + 1.5Lm(3) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ -.05 WLX -.086 6 1.5 47 1.2D + 1.5Lm(3) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ WLX -.1 6 1.5 48 1.2D + 1.5Lm(3) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ .05 WLX -.086 6 1.5 49 1.2D + 1.5Lm(3) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ .086 WLX -.05 6 1.5 RISA-3D Version 17.0.4 Page 11 [C:\...\...\...\...\...\...\Jacobs\Southern California\10087160 - WSLOS0068563\MA Rev 0\SICA001875 - 10087160.r3d] Company : BC Architects Engineers, PLC May 8, 2025 4:29 PMDesigner : Vamshi Krishna Job Number : SICA001875 Checked By: Rama Kristam Model Name : Antenna Mount Analysis Load Combinations (Continued) Description SolvePD... SR... BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor 50 1.2D + 1.5Lm(4) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ .1 WLX 7 1.5 51 1.2D + 1.5Lm(4) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ .086 WLX .05 7 1.5 52 1.2D + 1.5Lm(4) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ .05 WLX .086 7 1.5 53 1.2D + 1.5Lm(4) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ WLX .1 7 1.5 54 1.2D + 1.5Lm(4) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ -.05 WLX .086 7 1.5 55 1.2D + 1.5Lm(4) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ -.086 WLX .05 7 1.5 56 1.2D + 1.5Lm(4) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ -.1 WLX 7 1.5 57 1.2D + 1.5Lm(4) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ -.086 WLX -.05 7 1.5 58 1.2D + 1.5Lm(4) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ -.05 WLX -.086 7 1.5 59 1.2D + 1.5Lm(4) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ WLX -.1 7 1.5 60 1.2D + 1.5Lm(4) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ .05 WLX -.086 7 1.5 61 1.2D + 1.5Lm(4) + 1.0Wm (30 mph) AZ...Yes Y DL 1.2 WLZ .086 WLX -.05 7 1.5 62 1.0D + 1.0Ws (60 mph) AZI 000 Yes Y DL 1 WLZ .399 WLX 63 1.0D + 1.0Ws (60 mph) AZI 030 Yes Y DL 1 WLZ .345 WLX .199 64 1.0D + 1.0Ws (60 mph) AZI 060 Yes Y DL 1 WLZ .199 WLX .345 65 1.0D + 1.0Ws (60 mph) AZI 090 Yes Y DL 1 WLZ WLX .399 66 1.0D + 1.0Ws (60 mph) AZI 120 Yes Y DL 1 WLZ -.199 WLX .345 67 1.0D + 1.0Ws (60 mph) AZI 150 Yes Y DL 1 WLZ -.345 WLX .199 68 1.0D + 1.0Ws (60 mph) AZI 180 Yes Y DL 1 WLZ -.399 WLX 69 1.0D + 1.0Ws (60 mph) AZI 210 Yes Y DL 1 WLZ -.345 WLX -.199 70 1.0D + 1.0Ws (60 mph) AZI 240 Yes Y DL 1 WLZ -.199 WLX -.345 71 1.0D + 1.0Ws (60 mph) AZI 270 Yes Y DL 1 WLZ WLX -.399 72 1.0D + 1.0Ws (60 mph) AZI 300 Yes Y DL 1 WLZ .199 WLX -.345 73 1.0D + 1.0Ws (60 mph) AZI 330 Yes Y DL 1 WLZ .345 WLX -.199 74 1.2D + 1.5Lv(1)Yes Y DL 1.2 8 1.5 75 1.2D + 1.5Lv(2)Yes Y DL 1.2 9 1.5 76 1.2D + 1.5Lv(3)Yes Y DL 1.2 10 1.5 77 1.2D + 1.5Lv(4)Yes Y DL 1.2 11 1.5 78 1.2D + 1.5Lv(5)Yes Y DL 1.2 12 1.5 79 1.2D + 1.5Lv(6)Yes Y DL 1.2 13 1.5 80 1.2D + 1.0Ev + 1.0Eh AZI 000 Yes Y DL 1.2 ELZ -.516 ELX ELY -.206 81 1.2D + 1.0Ev + 1.0Eh AZI 030 Yes Y DL 1.2 ELZ -.447 ELX -.258 ELY -.206 82 1.2D + 1.0Ev + 1.0Eh AZI 060 Yes Y DL 1.2 ELZ -.258 ELX -.447 ELY -.206 83 1.2D + 1.0Ev + 1.0Eh AZI 090 Yes Y DL 1.2 ELZ ELX -.516 ELY -.206 84 1.2D + 1.0Ev + 1.0Eh AZI 120 Yes Y DL 1.2 ELZ .258 ELX -.447 ELY -.206 85 1.2D + 1.0Ev + 1.0Eh AZI 150 Yes Y DL 1.2 ELZ .447 ELX -.258 ELY -.206 86 1.2D + 1.0Ev + 1.0Eh AZI 180 Yes Y DL 1.2 ELZ .516 ELX ELY -.206 87 1.2D + 1.0Ev + 1.0Eh AZI 210 Yes Y DL 1.2 ELZ .447 ELX .258 ELY -.206 88 1.2D + 1.0Ev + 1.0Eh AZI 240 Yes Y DL 1.2 ELZ .258 ELX .447 ELY -.206 89 1.2D + 1.0Ev + 1.0Eh AZI 270 Yes Y DL 1.2 ELZ ELX .516 ELY -.206 RISA-3D Version 17.0.4 Page 12 [C:\...\...\...\...\...\...\Jacobs\Southern California\10087160 - WSLOS0068563\MA Rev 0\SICA001875 - 10087160.r3d] Company : BC Architects Engineers, PLC May 8, 2025 4:29 PMDesigner : Vamshi Krishna Job Number : SICA001875 Checked By: Rama Kristam Model Name : Antenna Mount Analysis Load Combinations (Continued) Description SolvePD... SR... BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor 90 1.2D + 1.0Ev + 1.0Eh AZI 300 Yes Y DL 1.2 ELZ -.258 ELX .447 ELY -.206 91 1.2D + 1.0Ev + 1.0Eh AZI 330 Yes Y DL 1.2 ELZ -.447 ELX .258 ELY -.206 Envelope Joint Reactions Joint X [lb] LC Y [lb] LC Z [lb] LC MX [k-ft] LC MY [k-ft] LC MZ [k-ft] LC 1 N68 max 1347.476 60 1066.905 56 2305.406 60 -.003 13 .46 59 .17 19 2 min -1790.576 18 559.206 62 941.457 83 -.221 7 -.593 17 -.146 61 3 N67 max 1748.541 23 1210.291 14 -545.243 7 -.539 7 .517 24 .494 54 4 min -1251.978 53 635.796 68 -2322.957 25 -1.298 25 -.312 54 -.703 24 5 N89 max 142.011 10 12.398 1 728.639 10 0 91 0 91 0 91 6 min -145.217 4 8.628 88 -747.108 4 0 1 0 1 0 1 7 N90 max 354.253 7 12.397 1 998.446 7 0 91 0 91 0 91 8 min -360.268 13 8.672 85 -1015.915 13 0 1 0 1 0 1 9 Totals:max 1126.106 11 2267.595 56 1912.943 8 10 min -1126.106 5 1256.539 80 -1912.944 2 Envelope AISC 15th(360-16): LRFD Steel Code Checks Member Shape Code Check Loc[in] LC Shear Check Loc[in] Dir LC phi*Pnc [...phi*Pnt [lb]phi*Mn y...phi*Mn z...Cb Eqn 1 M35 SR 3/4 .872 0 15 .008 0 13 1981.469 14313.882 .179 .179 2....H1-1a 2 M37 SR 3/4 .763 0 56 .003 42.081 3 1981.469 14313.882 .179 .179 2....H1-1a 3 M11 Pipe 2.88"x0.120".380 76.25 19 .075 76.25 20 15229.319 33712.054 2.47 2.47 4....H1-1b 4 M14 Pipe 2.88"x0.120".339 76.25 61 .067 43.75 54 15229.319 33712.054 2.47 2.47 4....H1-1b 5 M22 PL 3X5/8 .295 4 15 .086 4 y 32 97370.574 112500 1.466 9.375 1....H1-1b 6 M43 PL 3X5/8 .292 4 25 .080 4 y 36 97370.574 112500 1.466 9.375 1....H1-1b 7 M33 SR 3/4 .260 0 8 .014 33 15 3222.01 14313.882 .179 .179 1....H1-1a 8 M13 Pipe 2.88"x0.120".233 43.75 2 .064 43.75 2 15229.319 33712.054 2.47 2.47 3....H1-1b 9 M27 PL 4X1/2 .217 0 8 .051 2.004 y 2 88750.3 90000 .938 7.5 1....H1-1b 10 M6 Pipe 2.88"x0.276".206 106.25 25 .069 43.75 8 57329.034 73155.157 5.072 5.072 2....H1-1b 11 M25 PIPE_2.0 .202 36.2 16 .106 1.168 14 19503.255 33048 1.925 1.925 2....H1-1b 12 M40 PIPE_3.0 .200 10.5 24 .157 10.5 23 61412.302 67068 5.913 5.913 4....H1-1b 13 M1 Pipe 2.88"x0.276".199 106.25 25 .054 28.125 2 57329.034 73155.157 5.072 5.072 2....H1-1b 14 M30 PIPE_2.0 .182 36.2 59 .100 1.168 2 19503.255 33048 1.925 1.925 2....H1-1b 15 M24 PL 4X1/2 .176 2.013 15 .046 2.013 y 32 88738.962 90000 .938 7.5 1....H1-1b 16 M26 PL 4X1/2 .172 0 2 .038 0 y 44 88750.3 90000 .938 7.5 1....H1-1b 17 M20 PL 4X1/2 .166 2.013 25 .042 0 y 36 88738.962 90000 .938 7.5 1....H1-1b 18 M21 PIPE_2.0 .162 36.2 25 .100 37.368 25 19503.255 33048 1.925 1.925 1....H1-1b 19 M28 PL 4X1/2 .154 2.013 57 .047 2.013 y 44 88738.962 90000 .938 7.5 1....H1-1b RISA-3D Version 17.0.4 Page 13 [C:\...\...\...\...\...\...\Jacobs\Southern California\10087160 - WSLOS0068563\MA Rev 0\SICA001875 - 10087160.r3d] Company : BC Architects Engineers, PLC May 8, 2025 4:29 PMDesigner : Vamshi Krishna Job Number : SICA001875 Checked By: Rama Kristam Model Name : Antenna Mount Analysis Envelope AISC 15th(360-16): LRFD Steel Code Checks (Continued) Member Shape Code Check Loc[in] LC Shear Check Loc[in] Dir LC phi*Pnc [...phi*Pnt [lb]phi*Mn y...phi*Mn z...Cb Eqn 20 M19 PL 4X1/2 .152 2.004 25 .032 2.004 z 37 88750.3 90000 .938 7.5 1....H1-1b 21 M12 Pipe 2.88"x0.120".152 43.75 13 .044 43.75 15 15229.319 33712.054 2.47 2.47 1....H1-1b 22 M29 PL 4X1/2 .134 2.013 55 .050 0 y 2 88738.962 90000 .938 7.5 1....H1-1b 23 M31 PIPE_2.0 .131 36.2 55 .132 1.168 8 19503.255 33048 1.925 1.925 1....H1-1b 24 M23 PL 4X1/2 .125 2.004 22 .035 2.004 z 35 88750.3 90000 .938 7.5 1....H1-1b 25 M34 SR 3/4 .120 0 15 .006 0 17 1981.469 14313.882 .179 .179 2....H1-1b 26 M36 SR 3/4 .101 0 59 .007 0 9 1981.469 14313.882 .179 .179 2....H1-1b 27 M32 SR 3/4 .093 33 8 .014 33 15 3222.01 14313.882 .179 .179 2....H1-1b* 28 M47 Pipe 2.88"x0.120".038 60 7 .002 0 11 27638.154 33712.054 2.47 2.47 1....H1-1b* 29 M46 Pipe 2.88"x0.120".027 60 10 .002 0 11 27638.154 33712.054 2.47 2.47 1....H1-1b* RISA-3D Version 17.0.4 Page 14 [C:\...\...\...\...\...\...\Jacobs\Southern California\10087160 - WSLOS0068563\MA Rev 0\SICA001875 - 10087160.r3d] SEISMIC DESIGN DATA - RISK CATEGORY: - SEISMIC IMPORTANCE FACTOR, Ie: - MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETERS: - SITE CLASS: - DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETERS: - SEISMIC DESIGN CATEGORY: - DESIGN BASE SHEAR: - FUNDAMENTAL STRUCTURE FREQUENCY, f1: - RESPONSE MODIFICATION COEFFICIENT, R: - ANALYSIS METHOD: WIND DESIGN DATA - RISK CATEGORY: - EXPOSURE CATEGORY: - TOPOGRAPHIC CATEGORY: - TOPOGRAPHIC FACTOR, Kzt: - ULTIMATE WIND SPEED (3-SECOND GUST): II 1.0 Ss = 1.290 S1 = 0.462 D Sds = 1.032 Sd1 = 0.566 D 11.056 kips 1.3947 Hz 1.5 EQUIVALENT LATERAL FORCE PROCEDURE (METHOD I) PLANS PREPARED FOR: PROJECT INFORMATION: SHEET TITLE: SHEET NUMBER: TEP #: REVISION: SEAL: PLANS PREPARED BY: 326 TRYON ROAD RALEIGH, NC 27603 OFFICE: (919) 661-6351 www.tepgroup.net DRAWN BY: CHECKED BY: 2120 3/4 SOUTH BRISTOL SANTA ANA, CA 92704 (ORANGE) , RKE SMS 229344.113007 0DS-1 DRAWING SUMMARY THIS PAGE INTENTIONALLY LEFT BLANK 0 7-20-2025 STRUCTURAL ANALYSIS DATE ISSUED FOR:REV July 20, 2025 II C 1 1.000 95 MPH TEP is a family of companies licensed to provide different services in different jurisdictions. Depending on the jurisdiction, professional engineering and land surveying services are provided by TEP OpCo LLC, a Delaware limited liability company, TEP Engineering, PLLC, a North Carolina professional limited liability company, or M&H Engineering, PLLC, a New York professional limited liability company. General contractor services are provided by TEPDB OpCo LLC, a Delaware limited liability company. We acquire the requisite licenses in each state. Additional information can be obtained from the company. Date: July 20, 2025 326 Tryon Road Raleigh, NC 27603 (919) 661-6351 Subject: Structural Analysis Report Carrier Designation: AT&T Mobility Co-Locate Site Number: SICA001875 Site Name: EDINGER AND BRISTOL FA Number: 10087160 Crown Castle Designation: BU Number: 845391 Site Name: EDINGER AND BRISTOL JDE Job Number: 2152189 Work Order Number: 2408155 Order Number: 709035 Rev. 0 Engineering Firm Designation: TEP Project Number: 229344.1130072 Site Data: 2120 3/4 South Bristol, Santa Ana, Orange County, CA 92704 Latitude 33° 43' 8.44'', Longitude -117° 53' 12.85'' 60 Foot - Monopole Tower TEP is pleased to submit this “Structural Analysis Report” to determine the structural integrity of the above- mentioned tower. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case, to be: LC5: Proposed Equipment Configuration Sufficient Capacity This analysis has been performed in accordance with the 2022 California Building Code based upon an ultimate 3-second gust wind speed of 95 mph. Applicable Standard references and design criteria are listed in Section 2 - Analysis Criteria. Structural analysis prepared by: TG / SMS Respectfully submitted by: Adam M. Amortnont, P.E., S.E. July 20, 2025 60-ft Monopole Tower Structural Analysis Report CCI BU No 845391 TEP Project Number 229344.1130072, Order 709035, Revision 0 Page 2 tnxTower Report - version 8.3.1.2 TABLE OF CONTENTS 1) INTRODUCTION 2) ANALYSIS CRITERIA Table 1 - Proposed Equipment Configuration Table 2 - Other Considered Equipment 3) ANALYSIS PROCEDURE Table 3 - Documents Provided 3.1) Analysis Method 3.2) Assumptions 4) ANALYSIS RESULTS Table 4 - Section Capacity (Summary) Table 5 - Tower Component Stresses vs. Capacity 4.1) Recommendations 5) APPENDIX A tnxTower Output 6) APPENDIX B Base Level Drawing 7) APPENDIX C Additional Calculations July 20, 2025 60-ft Monopole Tower Structural Analysis Report CCI BU No 845391 TEP Project Number 229344.1130072, Order 709035, Revision 0 Page 3 tnxTower Report - version 8.3.1.2 1) INTRODUCTION This is a 60-ft monopole tower designed by Valmont. 2) ANALYSIS CRITERIA TIA-222 Revision: TIA-222-H Risk Category: II Wind Speed: 95 mph Exposure Category: C Topographic Factor: 1.0 Seismic Ss: 1.290 Seismic S1: 0.462 Service Wind Speed: 60 mph Table 1 - Proposed Equipment Configuration Mounting Level (ft) Center Line Elevation (ft) Number of Antennas Antenna Manufacturer Antenna Model Number of Feed Lines Feed Line Size (in) 59.0 59.0 3 Ericsson AIR 6419 B77G_2024 w/ Mount Pipe 1 3 7 18 1 5/16 3/8 3/4 7/8 2” Conduit 1 Tower Mounts Pipe Mount [PM 601-3] 1 Tower Mounts Sector Mount [SM 502-3] 57.0 3 Commscope NNH4-65C-R6-V3 w/ Mount Pipe 3 Kathrein 800 10866K w/ Mount Pipe 3 Kathrein 80010966 w/ Mount Pipe 3 Ericsson RRUS 4449 B5/B12 3 Ericsson RRUS 8843 B2/B66A_CCIV2 3 Raycap DC6-48-60-18-8F_070710 3 Ericsson RRUS 4478 B14_CCIV2 3 Ericsson RRUS 32 B30 55.0 3 Ericsson AIR 6449 B77D_CCIV3 w/ Mount Pipe Table 2 - Other Considered Equipment Mounting Level (ft) Center Line Elevation (ft) Number of Antennas Antenna Manufacturer Antenna Model Number of Feed Lines Feed Line Size (in) 48.0 48.0 2 Tower Mounts T-Arm Mount [TA 702-3] 3 1-5/8 46.0 3 Ericsson AIR6449 B41_T-MOBILE w/ Mount Pipe 45.0 3 RFS Celwave APXVAALL24_43-U- NA20_TMO w/ Mount Pipe 3 Ericsson RADIO 4480 B71_TMO 3 Ericsson RADIO 4460 B2/B25 B66_TMO July 20, 2025 60-ft Monopole Tower Structural Analysis Report CCI BU No 845391 TEP Project Number 229344.1130072, Order 709035, Revision 0 Page 4 tnxTower Report - version 8.3.1.2 Mounting Level (ft) Center Line Elevation (ft) Number of Antennas Antenna Manufacturer Antenna Model Number of Feed Lines Feed Line Size (in) 36.0 36.0 3 JMA Wireless MX08FRO665-21 w/ Mount Pipe 1 1-3/8 3 Samsung Telecom. RF4451d-70A 3 Samsung Telecom. RF4450t-71A 1 Raycap RDIDC-9181-PF-48 1 Tower Mounts Commscope MC-K6MHDX-9-96 (3) 3) ANALYSIS PROCEDURE Table 3 - Documents Provided Document Reference Source Geotechnical Report 4718580 CCISites Tower Foundation Drawings 5199492 CCISites Tower Manufacturer Drawings 4718581 CCISites 3.1) Analysis Method tnxTower (version 8.3.1.2), a commercially available analysis software package, was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A. When applicable, Crown Castle has calculated and provided the effective area for panel antennas using approved methods following the intent of the TIA-222 Standard. 3.2) Assumptions 1) The tower and structures were maintained in accordance with the TIA-222 Standard. 2) The configuration of antennas, transmission cables, mounts and other appurtenances are as specified in Tables 1 and 2, and the referenced drawings. This analysis may be affected if any assumptions are not valid or have been made in error. TEP should be notified to determine the effect on the structural integrity of the tower. 4) ANALYSIS RESULTS Table 4 - Section Capacity (Summary) Section No. Elevation (ft) Component Type Size Critical Element P (k) ΦΦΦΦPallow (k) % Capacity Pass / Fail L1 60 - 45 Pole TP33.2x33.2x0.25 1 -11.69 902.37 13.1 Pass L2 45 - 30 Pole TP33.2x33.2x0.25 2 -17.06 902.37 32.8 Pass L3 30 - 0 Pole TP37.7x33.2x0.2813 3 -22.61 1152.85 54.8 Pass Summary Pole (L3) 54.8 Pass RATING = 54.8 Pass July 20, 2025 60-ft Monopole Tower Structural Analysis Report CCI BU No 845391 TEP Project Number 229344.1130072, Order 709035, Revision 0 Page 5 tnxTower Report - version 8.3.1.2 Table 5 - Tower Component Stresses vs. Capacity - LC5 Notes Component Elevation (ft) % Capacity Pass / Fail 1,2 Flange Connection 45.0 11.9 Pass 1,2 Flange Connection 30.0 29.9 Pass 1,2 Anchor Rods - 82.4 Pass 1,2 Base Plate - 40.0 Pass 1,2 Base Foundation Structural - 24.9 Pass 1,2 Base Foundation Soil Interaction - 23.9 Pass Structure Rating (max from all components) = 82.4% Notes: 1) See additional documentation in "Appendix C - Additional Calculations" for calculations supporting the % capacity listed. 2) Rating per TIA-222-H Section 15.5 4.1) Recommendations 1) The tower and its foundation have sufficient capacity to carry the proposed load configuration. No modifications are required at this time. July 20, 2025 60-ft Monopole Tower Structural Analysis Report CCI BU No 845391 TEP Project Number 229344.1130072, Order 709035, Revision 0 Page 6 tnxTower Report - version 8.3.1.2 APPENDIX A TNXTOWER OUTPUT TEP 326 Tryon Road Raleigh, NC 27603 Phone: (919) 616-6351 FAX: (919) 616-6350 Job: EDINGER AND BRISTOL (BU 845391) Project: TEP No. 229344.1130072 Client: Crown Castle Drawn by: TG App'd: Code: TIA-222-H Date: 07/20/25 Scale: NTS Path: C:\Users\tsgore\OneDrive - Tower Engineering Professionals, Inc\Desktop\SA\2025-07-20 - Bonus\229344\P-485684_L-1130072_845391_EDINGER AND BRISTOL_Structural Analysis\tnxTower\Wind And Seismic\845391_2408155_LC5.eri Dwg No. E-1 60.0 ft 45.0 ft 30.0 ft 0.0 ft REACTIONS - 95 mph WIND TORQUE 0 kip-ft 9 K SHEAR 421 kip-ft MOMENT 19 K AXIAL SEISMIC 11 K SHEAR 547 kip-ft MOMENT 23 K AXIAL ARE FACTORED ALL REACTIONS S e c t i o n 1 2 3 L e n g t h ( f t ) 15 . 0 0 15 . 0 0 30 . 0 0 N u m b e r o f S i d e s 12 12 12 T h i c k n e s s ( i n ) 0. 2 5 0 0 0. 2 5 0 0 0. 2 8 1 2 T o p D i a ( i n ) 33 . 2 0 0 0 33 . 2 0 0 0 33 . 2 0 0 0 B o t D i a ( i n ) 33 . 2 0 0 0 33 . 2 0 0 0 37 . 7 0 0 0 G r a d e A3 6 W e i g h t ( K ) 1. 4 1. 4 3. 3 6. 0 MATERIAL STRENGTH GRADE GRADEFy FyFu Fu A36 36 ksi 58 ksi TOWER DESIGN NOTES 1. Tower designed for Exposure C to the TIA-222-H Standard. 2. Tower designed for a 95 mph basic wind in accordance with the TIA-222-H Standard. 3. Deflections are based upon a 60 mph wind. 4. Tower Risk Category II. 5. Topographic Category 1 with Crest Height of 0.00 ft 6. CCISeismic Note: Seismic loads generated by CCISeismic 5.0.2 7. CCISeismic Note: Seismic calculations are in accordance with TIA-222-H-1 8. TOWER RATING: 54.8% ttnnxxTToowweerr Job EDINGER AND BRISTOL (BU 845391) Page 1 of 21 TEP 326 Tryon Road Project TEP No. 229344.1130072 Date 12:45:44 07/20/25 Raleigh, NC 27603 Phone: (919) 616-6351 FAX: (919) 616-6350 Client Crown Castle Designed by TG Tower Input Data The tower is a monopole. This tower is designed using the TIA-222-H standard. The following design criteria apply: Tower base elevation above sea level: 49.00 ft. Basic wind speed of 95 mph. Risk Category II. Exposure Category C. Simplified Topographic Factor Procedure for wind speed-up calculations is used. Topographic Category: 1. Crest Height: 0.00 ft. Deflections calculated using a wind speed of 60 mph. CCISeismic Note: Seismic loads generated by CCISeismic 5.0.2. CCISeismic Note: Seismic calculations are in accordance with TIA -222-H-1. Non-linear (P-delta) analysis was used. Pressures are calculated at each section. Stress ratio used in pole design is 1. Tower analysis based on target reliabilities in accordance with Annex S. Load Modification Factors used: Kes(Fw) = 0.95, Kes(Ev and Eh) = 1.0. Maximum demand-capacity ratio is: 1.05. Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered. Options Consider Moments - Legs Assume Legs Pinned Calculate Redundant Bracing Forces Consider Moments - Horizontals √ Assume Rigid Index Plate Ignore Redundant Members in FEA Consider Moments - Diagonals √ Use Clear Spans For Wind Area SR Leg Bolts Resist Compression Use Moment Magnification Use Clear Spans For KL/r All Leg Panels Have Same Allowable √ Use Code Stress Ratios Retension Guys To Initial Tension Offset Girt At Foundation √ Use Code Safety Factors - Guys √ Bypass Mast Stability Checks √ Consider Feed Line Torque Escalate Ice √ Use Azimuth Dish Coefficients Include Angle Block Shear Check Always Use Max Kz √ Project Wind Area of Appurtenances Use TIA-222-H Bracing Resist. Exemption Kz In Exposure D Hurricane Region √ Alternative Appurt. EPA Calculation Use TIA-222-H Tension Splice Exemption Include Bolts In Member Capacity Autocalc Torque Arm Areas Poles Leg Bolts Are At Top Of Section Add IBC .6D+W Combination √ Include Shear-Torsion Interaction Secondary Horizontal Braces Leg √ Sort Capacity Reports By Component Always Use Sub-Critical Flow Use Diamond Inner Bracing (4 Sided) Triangulate Diamond Inner Bracing Use Top Mounted Sockets SR Members Have Cut Ends Treat Feed Line Bundles As Cylinder √ Pole Without Linear Attachments SR Members Are Concentric Ignore KL/ry For 60 Deg. Angle Legs Pole With Shroud Or No Appurtenances Distribute Leg Loads As Uniform Use ASCE 10 X-Brace Ly Rules Outside and Inside Corner Radii Are Known Use Special Wind Profile Tapered Pole Section Geometry Section Elevation ft Section Length ft Splice Length ft Number of Sides Top Diameter in Bottom Diameter in Wall Thickness in Bend Radius in Pole Grade L1 60.00-45.00 15.00 0.00 12 33.2000 33.2000 0.2500 1.0000 A36 (36 ksi) L2 45.00-30.00 15.00 0.00 12 33.2000 33.2000 0.2500 1.0000 A36 (36 ksi) L3 30.00-0.00 30.00 12 33.2000 37.7000 0.2812 1.1250 A36 (36 ksi) ttnnxxTToowweerr Job EDINGER AND BRISTOL (BU 845391) Page 2 of 21 TEP 326 Tryon Road Project TEP No. 229344.1130072 Date 12:45:44 07/20/25 Raleigh, NC 27603 Phone: (919) 616-6351 FAX: (919) 616-6350 Client Crown Castle Designed by TG Tapered Pole Properties Section Tip Dia. in Area in2 I in4 r in C in I/C in3 J in4 It/Q in2 w in w/t L1 34.2830 26.5248 3675.7680 11.7961 17.1976 213.7373 7448.1024 13.0547 8.2276 32.91 34.2830 26.5248 3675.7680 11.7961 17.1976 213.7373 7448.1024 13.0547 8.2276 32.91 L2 34.2830 26.5248 3675.7680 11.7961 17.1976 213.7373 7448.1024 13.0547 8.2276 32.91 34.2830 26.5248 3675.7680 11.7961 17.1976 213.7373 7448.1024 13.0547 8.2276 32.91 L3 34.2720 29.8120 4123.4844 11.7849 17.1976 239.7709 8355.2974 14.6726 8.1439 28.956 38.9307 33.8874 6056.2275 13.3959 19.5286 310.1209 12271.5588 16.6783 9.3498 33.244 Tower Elevation ft Gusset Area (per face) ft2 Gusset Thickness in Gusset Grade Adjust. Factor Af Adjust. Factor Ar Weight Mult. Double Angle Stitch Bolt Spacing Diagonals in Double Angle Stitch Bolt Spacing Horizontals in Double Angle Stitch Bolt Spacing Redundants in L1 60.00-45.00 1 1 1 L2 45.00-30.00 1 1 1 L3 30.00-0.00 1 1 1 Feed Line/Linear Appurtenances - Entered As Area Description Face or Leg Allow Shield Exclude From Torque Calculation Component Type Placement ft Total Number CAAA ft2/ft Weight plf ***misc*** Safety Line 3/8 B No No CaAa (Out Of Face) 60.00 - 0.00 1 No Ice 0.04 0.22 Step Pegs (5/8'' SR) 7-in. w/30'' step B No No CaAa (Out Of Face) 60.00 - 0.00 1 No Ice 0.03 0.49 ***59*** 123-171-XX(5/16) C No No Inside Pole 59.00 - 0.00 1 No Ice 0.00 0.07 FB-L98B-034-XXX XXX(3/8) C No No Inside Pole 59.00 - 0.00 3 No Ice 0.00 0.05 WR-VG86ST-BRD( 3/4) C No No Inside Pole 59.00 - 0.00 6 No Ice 0.00 0.58 WR-VG86ST-BRD( 3/4) C No No Inside Pole 59.00 - 0.00 1 No Ice 0.00 0.58 LDF5-50A(7/8) C No No Inside Pole 59.00 - 0.00 1 No Ice 0.00 0.33 LDF5-50A(7/8) C No No Inside Pole 59.00 - 0.00 17 No Ice 0.00 0.33 2'' Flexible Conduit C No No Inside Pole 59.00 - 0.00 1 No Ice 0.00 0.34 ***48*** HB158-21U6S24-xx M_TMO(1-5/8) B No No Inside Pole 48.00 - 0.00 3 No Ice 0.00 2.50 ***36*** CU12PSM9P8XXX( 1-3/8) B No No Inside Pole 36.00 - 0.00 1 No Ice 0.00 1.66 ttnnxxTToowweerr Job EDINGER AND BRISTOL (BU 845391) Page 3 of 21 TEP 326 Tryon Road Project TEP No. 229344.1130072 Date 12:45:44 07/20/25 Raleigh, NC 27603 Phone: (919) 616-6351 FAX: (919) 616-6350 Client Crown Castle Designed by TG Feed Line/Linear Appurtenances Section Areas Tower Section Tower Elevation ft Face AR ft2 AF ft2 CAAA In Face ft2 CAAA Out Face ft2 Weight K L1 60.00-45.00 A B C 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.087 0.000 0.00 0.03 0.15 L2 45.00-30.00 A B C 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.087 0.000 0.00 0.13 0.16 L3 30.00-0.00 A B C 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.175 0.000 0.00 0.30 0.32 Feed Line Center of Pressure Section Elevation ft CPX in CPZ in CPX Ice in CPZ Ice in L1 60.00-45.00 0.4168 0.2406 0.2977 0.1719 L2 45.00-30.00 0.4168 0.2406 0.2977 0.1719 L3 30.00-0.00 0.4176 0.2411 0.2982 0.1721 Note: For pole sections, center of pressure calculations do not consider feed line shielding. User Defined Loads - Seismic Description Elevation ft Offset From Centroid ft Azimuth Angle ° Ev K Ehx K Ehz K Eh K CCISeismic Tower Section 1 - 1 57.50 0.00 0.0000 0.09 0.00 0.00 0.45 CCISeismic Tower Section 1 - 2 50.00 0.00 0.0000 0.19 0.00 0.00 0.76 CCISeismic Tower Section 2 - 1 42.50 0.00 0.0000 0.09 0.00 0.00 0.32 CCISeismic Tower Section 2 - 2 35.00 0.00 0.0000 0.19 0.00 0.00 0.51 CCISeismic Tower Section 3 - 1 25.00 0.00 0.0000 0.21 0.00 0.00 0.41 CCISeismic Tower Section 3 - 2 15.00 0.00 0.0000 0.22 0.00 0.00 0.24 CCISeismic Tower Section 3 - 3 5.00 0.00 0.0000 0.23 0.00 0.00 0.07 CCISeismic commscope_cfd NNH4-65C-R6-V3 w/ Mount Pipe 59.00 0.00 0.0000 0.03 0.00 0.00 0.16 CCISeismic commscope_cfd NNH4-65C-R6-V3 w/ Mount Pipe 59.00 0.00 0.0000 0.03 0.00 0.00 0.16 CCISeismic commscope_cfd NNH4-65C-R6-V3 w/ Mount Pipe 59.00 0.00 0.0000 0.03 0.00 0.00 0.16 CCISeismic ericsson_cfd AIR 6419 B77G_2024 w/ Mount Pipe 59.00 0.00 0.0000 0.02 0.00 0.00 0.08 CCISeismic ericsson_cfd AIR 6419 B77G_2024 w/ Mount Pipe 59.00 0.00 0.0000 0.02 0.00 0.00 0.08 CCISeismic ericsson_cfd AIR 6419 B77G_2024 w/ Mount Pipe 59.00 0.00 0.0000 0.02 0.00 0.00 0.08 ttnnxxTToowweerr Job EDINGER AND BRISTOL (BU 845391) Page 4 of 21 TEP 326 Tryon Road Project TEP No. 229344.1130072 Date 12:45:44 07/20/25 Raleigh, NC 27603 Phone: (919) 616-6351 FAX: (919) 616-6350 Client Crown Castle Designed by TG Description Elevation ft Offset From Centroid ft Azimuth Angle ° Ev K Ehx K Ehz K Eh K CCISeismic ericsson_cfd AIR 6449 B77D_CCIV3 w/ Mount Pipe 59.00 0.00 0.0000 0.02 0.00 0.00 0.11 CCISeismic ericsson_cfd AIR 6449 B77D_CCIV3 w/ Mount Pipe 59.00 0.00 0.0000 0.02 0.00 0.00 0.11 CCISeismic ericsson_cfd AIR 6449 B77D_CCIV3 w/ Mount Pipe 59.00 0.00 0.0000 0.02 0.00 0.00 0.11 CCISeismic kathrein_cfd 800 10866K w/ Mount Pipe 59.00 0.00 0.0000 0.02 0.00 0.00 0.12 CCISeismic kathrein_cfd 800 10866K w/ Mount Pipe 59.00 0.00 0.0000 0.02 0.00 0.00 0.12 CCISeismic kathrein_cfd 800 10866K w/ Mount Pipe 59.00 0.00 0.0000 0.02 0.00 0.00 0.12 CCISeismic kathrein_cfd 80010966 w/ Mount Pipe 59.00 0.00 0.0000 0.03 0.00 0.00 0.16 CCISeismic kathrein_cfd 80010966 w/ Mount Pipe 59.00 0.00 0.0000 0.03 0.00 0.00 0.16 CCISeismic kathrein_cfd 80010966 w/ Mount Pipe 59.00 0.00 0.0000 0.03 0.00 0.00 0.16 CCISeismic ericsson RRUS 4449 B5/B12 59.00 0.00 0.0000 0.01 0.00 0.00 0.07 CCISeismic ericsson RRUS 4449 B5/B12 59.00 0.00 0.0000 0.01 0.00 0.00 0.07 CCISeismic ericsson RRUS 4449 B5/B12 59.00 0.00 0.0000 0.01 0.00 0.00 0.07 CCISeismic ericsson RRUS 8843 B2/B66A_CCIV2 59.00 0.00 0.0000 0.02 0.00 0.00 0.08 CCISeismic ericsson RRUS 8843 B2/B66A_CCIV2 59.00 0.00 0.0000 0.02 0.00 0.00 0.08 CCISeismic ericsson RRUS 8843 B2/B66A_CCIV2 59.00 0.00 0.0000 0.02 0.00 0.00 0.08 CCISeismic raycap DC6-48-60-18-8F_070710 59.00 0.00 0.0000 0.00 0.00 0.00 0.02 CCISeismic raycap DC6-48-60-18-8F_070710 59.00 0.00 0.0000 0.00 0.00 0.00 0.02 CCISeismic raycap DC6-48-60-18-8F_070710 59.00 0.00 0.0000 0.00 0.00 0.00 0.02 CCISeismic ericsson RRUS 4478 B14_CCIV2 59.00 0.00 0.0000 0.01 0.00 0.00 0.06 CCISeismic ericsson RRUS 4478 B14_CCIV2 59.00 0.00 0.0000 0.01 0.00 0.00 0.06 CCISeismic ericsson RRUS 4478 B14_CCIV2 59.00 0.00 0.0000 0.01 0.00 0.00 0.06 CCISeismic ericsson RRUS 32 B30 59.00 0.00 0.0000 0.01 0.00 0.00 0.05 CCISeismic ericsson RRUS 32 B30 59.00 0.00 0.0000 0.01 0.00 0.00 0.05 CCISeismic ericsson RRUS 32 B30 59.00 0.00 0.0000 0.01 0.00 0.00 0.05 CCISeismic 2.9'' Dia. x 6-ft Mount Pipe 59.00 0.00 0.0000 0.01 0.00 0.00 0.03 CCISeismic 2.9'' Dia. x 6-ft Mount Pipe 59.00 0.00 0.0000 0.01 0.00 0.00 0.03 CCISeismic 2.9'' Dia. x 6-ft Mount Pipe 59.00 0.00 0.0000 0.01 0.00 0.00 0.03 CCISeismic tower mounts (cci) Pipe Mount [PM 601-3] 59.00 0.00 0.0000 0.04 0.00 0.00 0.20 CCISeismic tower mounts (cci) 59.00 0.00 0.0000 0.35 0.00 0.00 1.70 ttnnxxTToowweerr Job EDINGER AND BRISTOL (BU 845391) Page 5 of 21 TEP 326 Tryon Road Project TEP No. 229344.1130072 Date 12:45:44 07/20/25 Raleigh, NC 27603 Phone: (919) 616-6351 FAX: (919) 616-6350 Client Crown Castle Designed by TG Description Elevation ft Offset From Centroid ft Azimuth Angle ° Ev K Ehx K Ehz K Eh K Sector Mount [SM 502-3] CCISeismic rfs celwave_cfd APXVAALL24_43-U-NA20_T MO w/ Mount Pipe 48.00 0.00 0.0000 0.04 0.00 0.00 0.15 CCISeismic rfs celwave_cfd APXVAALL24_43-U-NA20_T MO w/ Mount Pipe 48.00 0.00 0.0000 0.04 0.00 0.00 0.15 CCISeismic rfs celwave_cfd APXVAALL24_43-U-NA20_T MO w/ Mount Pipe 48.00 0.00 0.0000 0.04 0.00 0.00 0.15 CCISeismic ericsson_cfd AIR6449 B41_T-MOBILE w/ Mount Pipe 48.00 0.00 0.0000 0.03 0.00 0.00 0.10 CCISeismic ericsson_cfd AIR6449 B41_T-MOBILE w/ Mount Pipe 48.00 0.00 0.0000 0.03 0.00 0.00 0.10 CCISeismic ericsson_cfd AIR6449 B41_T-MOBILE w/ Mount Pipe 48.00 0.00 0.0000 0.03 0.00 0.00 0.10 CCISeismic ericsson RADIO 4480 B71_TMO 48.00 0.00 0.0000 0.02 0.00 0.00 0.07 CCISeismic ericsson RADIO 4480 B71_TMO 48.00 0.00 0.0000 0.02 0.00 0.00 0.07 CCISeismic ericsson RADIO 4480 B71_TMO 48.00 0.00 0.0000 0.02 0.00 0.00 0.07 CCISeismic ericsson RADIO 4460 B2/B25 B66_TMO 48.00 0.00 0.0000 0.02 0.00 0.00 0.09 CCISeismic ericsson RADIO 4460 B2/B25 B66_TMO 48.00 0.00 0.0000 0.02 0.00 0.00 0.09 CCISeismic ericsson RADIO 4460 B2/B25 B66_TMO 48.00 0.00 0.0000 0.02 0.00 0.00 0.09 CCISeismic (2) tower mounts (cci) T-Arm Mount [TA 702-3] 48.00 0.00 0.0000 0.14 0.00 0.00 0.55 CCISeismic jma wireless_cfd MX08FRO665-21 w/ Mount Pipe 36.00 0.00 0.0000 0.02 0.00 0.00 0.06 CCISeismic jma wireless_cfd MX08FRO665-21 w/ Mount Pipe 36.00 0.00 0.0000 0.02 0.00 0.00 0.06 CCISeismic jma wireless_cfd MX08FRO665-21 w/ Mount Pipe 36.00 0.00 0.0000 0.02 0.00 0.00 0.06 CCISeismic samsung telecommunications RF4451d-70A 36.00 0.00 0.0000 0.01 0.00 0.00 0.04 CCISeismic samsung telecommunications RF4451d-70A 36.00 0.00 0.0000 0.01 0.00 0.00 0.04 CCISeismic samsung telecommunications RF4451d-70A 36.00 0.00 0.0000 0.01 0.00 0.00 0.04 CCISeismic samsung telecommunications RF4450t-71A 36.00 0.00 0.0000 0.02 0.00 0.00 0.05 CCISeismic samsung telecommunications RF4450t-71A 36.00 0.00 0.0000 0.02 0.00 0.00 0.05 CCISeismic samsung telecommunications RF4450t-71A 36.00 0.00 0.0000 0.02 0.00 0.00 0.05 ttnnxxTToowweerr Job EDINGER AND BRISTOL (BU 845391) Page 6 of 21 TEP 326 Tryon Road Project TEP No. 229344.1130072 Date 12:45:44 07/20/25 Raleigh, NC 27603 Phone: (919) 616-6351 FAX: (919) 616-6350 Client Crown Castle Designed by TG Description Elevation ft Offset From Centroid ft Azimuth Angle ° Ev K Ehx K Ehz K Eh K CCISeismic raycap RDIDC-9181-PF-48 36.00 0.00 0.0000 0.00 0.00 0.00 0.01 CCISeismic (2) mounts 2.4'' Dia x 8-ft Mount Pipe 36.00 0.00 0.0000 0.01 0.00 0.00 0.04 CCISeismic (2) mounts 2.4'' Dia x 8-ft Mount Pipe 36.00 0.00 0.0000 0.01 0.00 0.00 0.04 CCISeismic (2) mounts 2.4'' Dia x 8-ft Mount Pipe 36.00 0.00 0.0000 0.01 0.00 0.00 0.04 CCISeismic tower mounts Commscope MC-K6MHDX-9-96 (3) 36.00 0.00 0.0000 0.25 0.00 0.00 0.70 CCISeismic miscl Safety Line 3/8 From 0 to 60 (50ft to60ft) 55.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic miscl Safety Line 3/8 From 0 to 60 (40ft to50ft) 45.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic miscl Safety Line 3/8 From 0 to 60 (30ft to40ft) 35.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic miscl Safety Line 3/8 From 0 to 60 (20ft to30ft) 25.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic miscl Safety Line 3/8 From 0 to 60 (10ft to20ft) 15.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic miscl Safety Line 3/8 From 0 to 60 (0ft to10ft) 5.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic miscl Step Pegs (5/8'' SR) 7-in. w/30'' step From 0 to 60 (50ft to60ft) 55.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic miscl Step Pegs (5/8'' SR) 7-in. w/30'' step From 0 to 60 (40ft to50ft) 45.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic miscl Step Pegs (5/8'' SR) 7-in. w/30'' step From 0 to 60 (30ft to40ft) 35.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic miscl Step Pegs (5/8'' SR) 7-in. w/30'' step From 0 to 60 (20ft to30ft) 25.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic miscl Step Pegs (5/8'' SR) 7-in. w/30'' step From 0 to 60 (10ft to20ft) 15.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic miscl Step Pegs (5/8'' SR) 7-in. w/30'' step From 0 to 60 (0ft to10ft) 5.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic 123ewireless 123-171-XX(5/16) From 0 to 59 (50ft to59ft) 54.50 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic 123ewireless 123-171-XX(5/16) From 0 to 59 (40ft to50ft) 45.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic 123ewireless 123-171-XX(5/16) From 0 to 59 (30ft to40ft) 35.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic 123ewireless 123-171-XX(5/16) From 0 to 59 (20ft to30ft) 25.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic 123ewireless 123-171-XX(5/16) From 0 to 59 (10ft to20ft) 15.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic 123ewireless 123-171-XX(5/16) From 0 to 59 (0ft to10ft) 5.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic (3) rosenberger 54.50 0.00 0.0000 0.00 0.00 0.00 0.00 ttnnxxTToowweerr Job EDINGER AND BRISTOL (BU 845391) Page 7 of 21 TEP 326 Tryon Road Project TEP No. 229344.1130072 Date 12:45:44 07/20/25 Raleigh, NC 27603 Phone: (919) 616-6351 FAX: (919) 616-6350 Client Crown Castle Designed by TG Description Elevation ft Offset From Centroid ft Azimuth Angle ° Ev K Ehx K Ehz K Eh K leoni FB-L98B-034-XXXXXX(3/8) From 0 to 59 (50ft to59ft) CCISeismic (3) rosenberger leoni FB-L98B-034-XXXXXX(3/8) From 0 to 59 (40ft to50ft) 45.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic (3) rosenberger leoni FB-L98B-034-XXXXXX(3/8) From 0 to 59 (30ft to40ft) 35.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic (3) rosenberger leoni FB-L98B-034-XXXXXX(3/8) From 0 to 59 (20ft to30ft) 25.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic (3) rosenberger leoni FB-L98B-034-XXXXXX(3/8) From 0 to 59 (10ft to20ft) 15.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic (3) rosenberger leoni FB-L98B-034-XXXXXX(3/8) From 0 to 59 (0ft to10ft) 5.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic (6) rosenberger leoni WR-VG86ST-BRD(3/4) From 0 to 59 (50ft to59ft) 54.50 0.00 0.0000 0.01 0.00 0.00 0.03 CCISeismic (6) rosenberger leoni WR-VG86ST-BRD(3/4) From 0 to 59 (40ft to50ft) 45.00 0.00 0.0000 0.01 0.00 0.00 0.03 CCISeismic (6) rosenberger leoni WR-VG86ST-BRD(3/4) From 0 to 59 (30ft to40ft) 35.00 0.00 0.0000 0.01 0.00 0.00 0.02 CCISeismic (6) rosenberger leoni WR-VG86ST-BRD(3/4) From 0 to 59 (20ft to30ft) 25.00 0.00 0.0000 0.01 0.00 0.00 0.01 CCISeismic (6) rosenberger leoni WR-VG86ST-BRD(3/4) From 0 to 59 (10ft to20ft) 15.00 0.00 0.0000 0.01 0.00 0.00 0.01 CCISeismic (6) rosenberger leoni WR-VG86ST-BRD(3/4) From 0 to 59 (0ft to10ft) 5.00 0.00 0.0000 0.01 0.00 0.00 0.00 CCISeismic rosenberger leoni WR-VG86ST-BRD(3/4) From 0 to 59 (50ft to59ft) 54.50 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic rosenberger leoni WR-VG86ST-BRD(3/4) From 0 to 59 (40ft to50ft) 45.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic rosenberger leoni WR-VG86ST-BRD(3/4) From 0 to 59 (30ft to40ft) 35.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic rosenberger leoni WR-VG86ST-BRD(3/4) From 0 to 59 (20ft to30ft) 25.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic rosenberger leoni WR-VG86ST-BRD(3/4) From 0 to 59 (10ft to20ft) 15.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic rosenberger leoni WR-VG86ST-BRD(3/4) From 0 to 59 (0ft to10ft) 5.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic andrew 54.50 0.00 0.0000 0.00 0.00 0.00 0.00 ttnnxxTToowweerr Job EDINGER AND BRISTOL (BU 845391) Page 8 of 21 TEP 326 Tryon Road Project TEP No. 229344.1130072 Date 12:45:44 07/20/25 Raleigh, NC 27603 Phone: (919) 616-6351 FAX: (919) 616-6350 Client Crown Castle Designed by TG Description Elevation ft Offset From Centroid ft Azimuth Angle ° Ev K Ehx K Ehz K Eh K LDF5-50A(7/8) From 0 to 59 (50ft to59ft) CCISeismic andrew LDF5-50A(7/8) From 0 to 59 (40ft to50ft) 45.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic andrew LDF5-50A(7/8) From 0 to 59 (30ft to40ft) 35.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic andrew LDF5-50A(7/8) From 0 to 59 (20ft to30ft) 25.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic andrew LDF5-50A(7/8) From 0 to 59 (10ft to20ft) 15.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic andrew LDF5-50A(7/8) From 0 to 59 (0ft to10ft) 5.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic (17) andrew LDF5-50A(7/8) From 0 to 59 (50ft to59ft) 54.50 0.00 0.0000 0.01 0.00 0.00 0.05 CCISeismic (17) andrew LDF5-50A(7/8) From 0 to 59 (40ft to50ft) 45.00 0.00 0.0000 0.01 0.00 0.00 0.04 CCISeismic (17) andrew LDF5-50A(7/8) From 0 to 59 (30ft to40ft) 35.00 0.00 0.0000 0.01 0.00 0.00 0.03 CCISeismic (17) andrew LDF5-50A(7/8) From 0 to 59 (20ft to30ft) 25.00 0.00 0.0000 0.01 0.00 0.00 0.02 CCISeismic (17) andrew LDF5-50A(7/8) From 0 to 59 (10ft to20ft) 15.00 0.00 0.0000 0.01 0.00 0.00 0.01 CCISeismic (17) andrew LDF5-50A(7/8) From 0 to 59 (0ft to10ft) 5.00 0.00 0.0000 0.01 0.00 0.00 0.00 CCISeismic miscl 2'' Flexible Conduit From 0 to 59 (50ft to59ft) 54.50 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic miscl 2'' Flexible Conduit From 0 to 59 (40ft to50ft) 45.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic miscl 2'' Flexible Conduit From 0 to 59 (30ft to40ft) 35.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic miscl 2'' Flexible Conduit From 0 to 59 (20ft to30ft) 25.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic miscl 2'' Flexible Conduit From 0 to 59 (10ft to20ft) 15.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic miscl 2'' Flexible Conduit From 0 to 59 (0ft to10ft) 5.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic (3) rfs celwave HB158-21U6S24-xxM_TMO(1- 5/8) From 0 to 48 (40ft to48ft) 44.00 0.00 0.0000 0.01 0.00 0.00 0.04 CCISeismic (3) rfs celwave HB158-21U6S24-xxM_TMO(1- 5/8) From 0 to 48 (30ft to40ft) 35.00 0.00 0.0000 0.02 0.00 0.00 0.04 CCISeismic (3) rfs celwave HB158-21U6S24-xxM_TMO(1- 25.00 0.00 0.0000 0.02 0.00 0.00 0.03 ttnnxxTToowweerr Job EDINGER AND BRISTOL (BU 845391) Page 9 of 21 TEP 326 Tryon Road Project TEP No. 229344.1130072 Date 12:45:44 07/20/25 Raleigh, NC 27603 Phone: (919) 616-6351 FAX: (919) 616-6350 Client Crown Castle Designed by TG Description Elevation ft Offset From Centroid ft Azimuth Angle ° Ev K Ehx K Ehz K Eh K 5/8) From 0 to 48 (20ft to30ft) CCISeismic (3) rfs celwave HB158-21U6S24-xxM_TMO(1- 5/8) From 0 to 48 (10ft to20ft) 15.00 0.00 0.0000 0.02 0.00 0.00 0.02 CCISeismic (3) rfs celwave HB158-21U6S24-xxM_TMO(1- 5/8) From 0 to 48 (0ft to10ft) 5.00 0.00 0.0000 0.02 0.00 0.00 0.01 CCISeismic cui CU12PSM9P8XXX(1-3/8) From 0 to 36 (30ft to36ft) 33.00 0.00 0.0000 0.00 0.00 0.00 0.01 CCISeismic cui CU12PSM9P8XXX(1-3/8) From 0 to 36 (20ft to30ft) 25.00 0.00 0.0000 0.00 0.00 0.00 0.01 CCISeismic cui CU12PSM9P8XXX(1-3/8) From 0 to 36 (10ft to20ft) 15.00 0.00 0.0000 0.00 0.00 0.00 0.00 CCISeismic cui CU12PSM9P8XXX(1-3/8) From 0 to 36 (0ft to10ft) 5.00 0.00 0.0000 0.00 0.00 0.00 0.00 Discrete Tower Loads Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustment ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K ***59*** NNH4-65C-R6-V3 w/ Mount Pipe A From Leg 4.00 0.00 -2.00 0.0000 59.00 No Ice 9.68 5.17 0.16 NNH4-65C-R6-V3 w/ Mount Pipe B From Leg 4.00 0.00 -2.00 0.0000 59.00 No Ice 9.68 5.17 0.16 NNH4-65C-R6-V3 w/ Mount Pipe C From Leg 4.00 0.00 -2.00 0.0000 59.00 No Ice 9.68 5.17 0.16 AIR 6419 B77G_2024 w/ Mount Pipe A From Leg 4.00 0.00 0.00 0.0000 59.00 No Ice 3.43 1.95 0.08 AIR 6419 B77G_2024 w/ Mount Pipe B From Leg 4.00 0.00 0.00 0.0000 59.00 No Ice 3.43 1.95 0.08 AIR 6419 B77G_2024 w/ Mount Pipe C From Leg 4.00 0.00 0.00 0.0000 59.00 No Ice 3.43 1.95 0.08 AIR 6449 B77D_CCIV3 w/ Mount Pipe A From Leg 4.00 0.00 -4.00 0.0000 59.00 No Ice 3.65 2.72 0.11 AIR 6449 B77D_CCIV3 w/ Mount Pipe B From Leg 4.00 0.00 -4.00 0.0000 59.00 No Ice 3.65 2.72 0.11 AIR 6449 B77D_CCIV3 w/ C From Leg 4.00 0.0000 59.00 No Ice 3.65 2.72 0.11 ttnnxxTToowweerr Job EDINGER AND BRISTOL (BU 845391) Page 10 of 21 TEP 326 Tryon Road Project TEP No. 229344.1130072 Date 12:45:44 07/20/25 Raleigh, NC 27603 Phone: (919) 616-6351 FAX: (919) 616-6350 Client Crown Castle Designed by TG Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustment ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K Mount Pipe 0.00 -4.00 800 10866K w/ Mount Pipe A From Leg 4.00 0.00 -2.00 0.0000 59.00 No Ice 8.78 5.45 0.11 800 10866K w/ Mount Pipe B From Leg 4.00 0.00 -2.00 0.0000 59.00 No Ice 8.78 5.45 0.11 800 10866K w/ Mount Pipe C From Leg 4.00 0.00 -2.00 0.0000 59.00 No Ice 8.78 5.45 0.11 80010966 w/ Mount Pipe A From Leg 4.00 0.00 -2.00 0.0000 59.00 No Ice 14.61 6.84 0.16 80010966 w/ Mount Pipe B From Leg 4.00 0.00 -2.00 0.0000 59.00 No Ice 14.61 6.84 0.16 80010966 w/ Mount Pipe C From Leg 4.00 0.00 -2.00 0.0000 59.00 No Ice 14.61 6.84 0.16 RRUS 4449 B5/B12 A From Leg 4.00 0.00 -2.00 0.0000 59.00 No Ice 1.97 1.41 0.07 RRUS 4449 B5/B12 B From Leg 4.00 0.00 -2.00 0.0000 59.00 No Ice 1.97 1.41 0.07 RRUS 4449 B5/B12 C From Leg 4.00 0.00 -2.00 0.0000 59.00 No Ice 1.97 1.41 0.07 RRUS 8843 B2/B66A_CCIV2 A From Leg 4.00 0.00 -2.00 0.0000 59.00 No Ice 1.98 1.70 0.08 RRUS 8843 B2/B66A_CCIV2 B From Leg 4.00 0.00 -2.00 0.0000 59.00 No Ice 1.98 1.70 0.08 RRUS 8843 B2/B66A_CCIV2 C From Leg 4.00 0.00 -2.00 0.0000 59.00 No Ice 1.98 1.70 0.08 DC6-48-60-18-8F_070710 A From Leg 4.00 0.00 -2.00 0.0000 59.00 No Ice 2.20 1.81 0.02 DC6-48-60-18-8F_070710 B From Leg 4.00 0.00 -2.00 0.0000 59.00 No Ice 2.20 1.81 0.02 DC6-48-60-18-8F_070710 C From Leg 4.00 0.00 -2.00 0.0000 59.00 No Ice 2.20 1.81 0.02 RRUS 4478 B14_CCIV2 A From Leg 4.00 0.00 -2.00 0.0000 59.00 No Ice 2.02 1.25 0.06 RRUS 4478 B14_CCIV2 B From Leg 4.00 0.00 -2.00 0.0000 59.00 No Ice 2.02 1.25 0.06 RRUS 4478 B14_CCIV2 C From Leg 4.00 0.00 -2.00 0.0000 59.00 No Ice 2.02 1.25 0.06 RRUS 32 B30 A From Leg 4.00 0.0000 59.00 No Ice 2.73 1.67 0.05 ttnnxxTToowweerr Job EDINGER AND BRISTOL (BU 845391) Page 11 of 21 TEP 326 Tryon Road Project TEP No. 229344.1130072 Date 12:45:44 07/20/25 Raleigh, NC 27603 Phone: (919) 616-6351 FAX: (919) 616-6350 Client Crown Castle Designed by TG Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustment ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K 0.00 -2.00 RRUS 32 B30 B From Leg 4.00 0.00 -2.00 0.0000 59.00 No Ice 2.73 1.67 0.05 RRUS 32 B30 C From Leg 4.00 0.00 -2.00 0.0000 59.00 No Ice 2.73 1.67 0.05 2.9'' Dia. x 6-ft Mount Pipe A From Leg 2.00 0.00 0.00 0.0000 59.00 No Ice 0.00 1.73 0.03 2.9'' Dia. x 6-ft Mount Pipe B From Leg 2.00 0.00 0.00 0.0000 59.00 No Ice 0.00 1.73 0.03 2.9'' Dia. x 6-ft Mount Pipe C From Leg 2.00 0.00 0.00 0.0000 59.00 No Ice 0.00 1.73 0.03 Pipe Mount [PM 601-3] C None 0.0000 59.00 No Ice 3.17 3.17 0.20 Sector Mount [SM 502-3] C None 0.0000 59.00 No Ice 29.82 29.82 1.67 ***48*** APXVAALL24_43-U-NA20 _TMO w/ Mount Pipe A From Leg 3.00 0.00 -3.00 0.0000 48.00 No Ice 14.69 6.87 0.18 APXVAALL24_43-U-NA20 _TMO w/ Mount Pipe B From Leg 3.00 0.00 -3.00 0.0000 48.00 No Ice 14.69 6.87 0.18 APXVAALL24_43-U-NA20 _TMO w/ Mount Pipe C From Leg 3.00 0.00 -3.00 0.0000 48.00 No Ice 14.69 6.87 0.18 AIR6449 B41_T-MOBILE w/ Mount Pipe A From Leg 3.00 0.00 -2.00 0.0000 48.00 No Ice 5.19 2.71 0.13 AIR6449 B41_T-MOBILE w/ Mount Pipe B From Leg 3.00 0.00 -2.00 0.0000 48.00 No Ice 5.19 2.71 0.13 AIR6449 B41_T-MOBILE w/ Mount Pipe C From Leg 3.00 0.00 -2.00 0.0000 48.00 No Ice 5.19 2.71 0.13 RADIO 4480 B71_TMO A From Leg 3.00 0.00 -3.00 0.0000 48.00 No Ice 2.85 1.38 0.09 RADIO 4480 B71_TMO B From Leg 3.00 0.00 -3.00 0.0000 48.00 No Ice 2.85 1.38 0.09 RADIO 4480 B71_TMO C From Leg 3.00 0.00 -3.00 0.0000 48.00 No Ice 2.85 1.38 0.09 RADIO 4460 B2/B25 B66_TMO A From Leg 3.00 0.00 -3.00 0.0000 48.00 No Ice 2.14 1.69 0.11 RADIO 4460 B2/B25 B66_TMO B From Leg 3.00 0.00 -3.00 0.0000 48.00 No Ice 2.14 1.69 0.11 RADIO 4460 B2/B25 B66_TMO C From Leg 3.00 0.00 -3.00 0.0000 48.00 No Ice 2.14 1.69 0.11 (2) T-Arm Mount [TA 702-3] C None 0.0000 48.00 No Ice 4.75 4.75 0.34 ttnnxxTToowweerr Job EDINGER AND BRISTOL (BU 845391) Page 12 of 21 TEP 326 Tryon Road Project TEP No. 229344.1130072 Date 12:45:44 07/20/25 Raleigh, NC 27603 Phone: (919) 616-6351 FAX: (919) 616-6350 Client Crown Castle Designed by TG Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustment ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K ***36*** MX08FRO665-21 w/ Mount Pipe A From Leg 4.00 0.00 0.00 0.0000 36.00 No Ice 8.01 4.23 0.11 MX08FRO665-21 w/ Mount Pipe B From Leg 4.00 0.00 0.00 0.0000 36.00 No Ice 8.01 4.23 0.11 MX08FRO665-21 w/ Mount Pipe C From Leg 4.00 0.00 0.00 0.0000 36.00 No Ice 8.01 4.23 0.11 RF4451d-70A A From Leg 4.00 0.00 0.00 0.0000 36.00 No Ice 1.88 1.11 0.06 RF4451d-70A B From Leg 4.00 0.00 0.00 0.0000 36.00 No Ice 1.88 1.11 0.06 RF4451d-70A C From Leg 4.00 0.00 0.00 0.0000 36.00 No Ice 1.88 1.11 0.06 RF4450t-71A A From Leg 4.00 0.00 0.00 0.0000 36.00 No Ice 2.06 1.38 0.09 RF4450t-71A B From Leg 4.00 0.00 0.00 0.0000 36.00 No Ice 2.06 1.38 0.09 RF4450t-71A C From Leg 4.00 0.00 0.00 0.0000 36.00 No Ice 2.06 1.38 0.09 RDIDC-9181-PF-48 A From Leg 4.00 0.00 0.00 0.0000 36.00 No Ice 2.01 1.17 0.02 (2) 2.4'' Dia x 8-ft Mount Pipe A From Leg 4.00 0.00 0.00 0.0000 36.00 No Ice 1.90 1.90 0.03 (2) 2.4'' Dia x 8-ft Mount Pipe B From Leg 4.00 0.00 0.00 0.0000 36.00 No Ice 1.90 1.90 0.03 (2) 2.4'' Dia x 8-ft Mount Pipe C From Leg 4.00 0.00 0.00 0.0000 36.00 No Ice 1.90 1.90 0.03 Commscope MC-K6MHDX-9-96 (3) C None 0.0000 36.00 No Ice 15.30 15.30 1.19 ****** Load Combinations Comb. No. Description 1 Dead Only 2 1.2 Dead+1.0 Wind 0 deg - No Ice 3 0.9 Dead+1.0 Wind 0 deg - No Ice 4 1.2 Dead+1.0 Wind 30 deg - No Ice 5 0.9 Dead+1.0 Wind 30 deg - No Ice 6 1.2 Dead+1.0 Wind 60 deg - No Ice ttnnxxTToowweerr Job EDINGER AND BRISTOL (BU 845391) Page 13 of 21 TEP 326 Tryon Road Project TEP No. 229344.1130072 Date 12:45:44 07/20/25 Raleigh, NC 27603 Phone: (919) 616-6351 FAX: (919) 616-6350 Client Crown Castle Designed by TG Comb. No. Description 7 0.9 Dead+1.0 Wind 60 deg - No Ice 8 1.2 Dead+1.0 Wind 90 deg - No Ice 9 0.9 Dead+1.0 Wind 90 deg - No Ice 10 1.2 Dead+1.0 Wind 120 deg - No Ice 11 0.9 Dead+1.0 Wind 120 deg - No Ice 12 1.2 Dead+1.0 Wind 150 deg - No Ice 13 0.9 Dead+1.0 Wind 150 deg - No Ice 14 1.2 Dead+1.0 Wind 180 deg - No Ice 15 0.9 Dead+1.0 Wind 180 deg - No Ice 16 1.2 Dead+1.0 Wind 210 deg - No Ice 17 0.9 Dead+1.0 Wind 210 deg - No Ice 18 1.2 Dead+1.0 Wind 240 deg - No Ice 19 0.9 Dead+1.0 Wind 240 deg - No Ice 20 1.2 Dead+1.0 Wind 270 deg - No Ice 21 0.9 Dead+1.0 Wind 270 deg - No Ice 22 1.2 Dead+1.0 Wind 300 deg - No Ice 23 0.9 Dead+1.0 Wind 300 deg - No Ice 24 1.2 Dead+1.0 Wind 330 deg - No Ice 25 0.9 Dead+1.0 Wind 330 deg - No Ice 26 Dead+Wind 0 deg - Service 27 Dead+Wind 30 deg - Service 28 Dead+Wind 60 deg - Service 29 Dead+Wind 90 deg - Service 30 Dead+Wind 120 deg - Service 31 Dead+Wind 150 deg - Service 32 Dead+Wind 180 deg - Service 33 Dead+Wind 210 deg - Service 34 Dead+Wind 240 deg - Service 35 Dead+Wind 270 deg - Service 36 Dead+Wind 300 deg - Service 37 Dead+Wind 330 deg - Service 38 1.2 Dead+1.0 Ev+1.0 Eh 0 deg 39 0.9 Dead-1.0 Ev+1.0 Eh 0 deg 40 1.2 Dead+1.0 Ev+1.0 Eh 30 deg 41 0.9 Dead-1.0 Ev+1.0 Eh 30 deg 42 1.2 Dead+1.0 Ev+1.0 Eh 60 deg 43 0.9 Dead-1.0 Ev+1.0 Eh 60 deg 44 1.2 Dead+1.0 Ev+1.0 Eh 90 deg 45 0.9 Dead-1.0 Ev+1.0 Eh 90 deg 46 1.2 Dead+1.0 Ev+1.0 Eh 120 deg 47 0.9 Dead-1.0 Ev+1.0 Eh 120 deg 48 1.2 Dead+1.0 Ev+1.0 Eh 150 deg 49 0.9 Dead-1.0 Ev+1.0 Eh 150 deg 50 1.2 Dead+1.0 Ev+1.0 Eh 180 deg 51 0.9 Dead-1.0 Ev+1.0 Eh 180 deg 52 1.2 Dead+1.0 Ev+1.0 Eh 210 deg 53 0.9 Dead-1.0 Ev+1.0 Eh 210 deg 54 1.2 Dead+1.0 Ev+1.0 Eh 240 deg 55 0.9 Dead-1.0 Ev+1.0 Eh 240 deg 56 1.2 Dead+1.0 Ev+1.0 Eh 270 deg 57 0.9 Dead-1.0 Ev+1.0 Eh 270 deg 58 1.2 Dead+1.0 Ev+1.0 Eh 300 deg 59 0.9 Dead-1.0 Ev+1.0 Eh 300 deg 60 1.2 Dead+1.0 Ev+1.0 Eh 330 deg 61 0.9 Dead-1.0 Ev+1.0 Eh 330 deg ttnnxxTToowweerr Job EDINGER AND BRISTOL (BU 845391) Page 14 of 21 TEP 326 Tryon Road Project TEP No. 229344.1130072 Date 12:45:44 07/20/25 Raleigh, NC 27603 Phone: (919) 616-6351 FAX: (919) 616-6350 Client Crown Castle Designed by TG Maximum Member Forces Section No. Elevation ft Component Type Condition Gov. Load Comb. Axial K Major Axis Moment kip-ft Minor Axis Moment kip-ft L1 60 - 45 Pole Max Tension 56 0.00 -0.00 -0.00 Max. Compression 52 -11.69 41.87 -72.55 Max. Mx 44 -11.69 -83.79 -0.01 Max. My 50 -11.69 -0.02 -83.78 Max. Vy 44 8.01 -83.79 -0.01 Max. Vx 38 -8.01 -0.02 83.76 Max. Torque 17 0.04 L2 45 - 30 Pole Max Tension 1 0.00 0.00 0.00 Max. Compression 52 -17.06 110.34 -191.05 Max. Mx 44 -17.06 -220.77 0.11 Max. My 38 -17.06 -0.03 220.85 Max. Vy 44 10.39 -200.00 0.11 Max. Vx 38 -10.39 -0.03 200.08 Max. Torque 22 -0.10 L3 30 - 0 Pole Max Tension 1 0.00 0.00 0.00 Max. Compression 52 -22.61 273.38 -473.52 Max. Mx 44 -22.61 -546.95 0.09 Max. My 38 -22.61 -0.06 546.98 Max. Vy 44 11.11 -497.10 0.10 Max. Vx 38 -11.11 -0.06 497.13 Max. Torque 24 -0.13 Maximum Reactions Location Condition Gov. Load Comb. Vertical K Horizontal, X K Horizontal, Z K Pole Max. Vert 44 22.61 -11.06 0.00 Max. Hx 56 22.61 11.06 0.00 Max. Hz 38 22.61 0.00 11.06 Max. Mx 38 546.98 0.00 11.06 Max. Mz 44 546.95 -11.06 0.00 Max. Torsion 12 0.13 -4.73 -8.21 Min. Vert 53 11.15 5.53 -9.57 Min. Hx 44 22.61 -11.06 0.00 Min. Hz 50 22.61 0.00 -11.06 Min. Mx 50 -546.79 0.00 -11.06 Min. Mz 56 -546.82 11.06 0.00 Min. Torsion 24 -0.13 4.73 8.21 Tower Mast Reaction Summary Load Combination Vertical K Shearx K Shearz K Overturning Moment, Mx kip-ft Overturning Moment, Mz kip-ft Torque kip-ft Dead Only 16.08 0.00 0.00 -0.08 -0.05 0.00 1.2 Dead+1.0 Wind 0 deg - No Ice 19.29 0.00 -9.49 -421.25 -0.06 0.12 0.9 Dead+1.0 Wind 0 deg - No 14.47 0.00 -9.49 -419.96 -0.05 0.12 ttnnxxTToowweerr Job EDINGER AND BRISTOL (BU 845391) Page 15 of 21 TEP 326 Tryon Road Project TEP No. 229344.1130072 Date 12:45:44 07/20/25 Raleigh, NC 27603 Phone: (919) 616-6351 FAX: (919) 616-6350 Client Crown Castle Designed by TG Load Combination Vertical K Shearx K Shearz K Overturning Moment, Mx kip-ft Overturning Moment, Mz kip-ft Torque kip-ft Ice 1.2 Dead+1.0 Wind 30 deg - No Ice 19.29 4.73 -8.21 -364.82 -210.35 0.08 0.9 Dead+1.0 Wind 30 deg - No Ice 14.47 4.73 -8.21 -363.71 -209.71 0.08 1.2 Dead+1.0 Wind 60 deg - No Ice 19.29 8.20 -4.74 -210.67 -364.30 0.01 0.9 Dead+1.0 Wind 60 deg - No Ice 14.47 8.20 -4.74 -210.02 -363.19 0.02 1.2 Dead+1.0 Wind 90 deg - No Ice 19.29 9.47 0.00 -0.09 -420.64 -0.05 0.9 Dead+1.0 Wind 90 deg - No Ice 14.47 9.47 0.00 -0.07 -419.37 -0.05 1.2 Dead+1.0 Wind 120 deg - No Ice 19.29 8.20 4.74 210.48 -364.30 -0.10 0.9 Dead+1.0 Wind 120 deg - No Ice 14.47 8.20 4.74 209.88 -363.19 -0.10 1.2 Dead+1.0 Wind 150 deg - No Ice 19.29 4.73 8.21 364.63 -210.35 -0.13 0.9 Dead+1.0 Wind 150 deg - No Ice 14.47 4.73 8.21 363.57 -209.71 -0.13 1.2 Dead+1.0 Wind 180 deg - No Ice 19.29 0.00 9.49 421.06 -0.06 -0.12 0.9 Dead+1.0 Wind 180 deg - No Ice 14.47 0.00 9.49 419.82 -0.05 -0.12 1.2 Dead+1.0 Wind 210 deg - No Ice 19.29 -4.73 8.21 364.63 210.23 -0.08 0.9 Dead+1.0 Wind 210 deg - No Ice 14.47 -4.73 8.21 363.57 209.61 -0.08 1.2 Dead+1.0 Wind 240 deg - No Ice 19.29 -8.20 4.74 210.48 364.17 -0.01 0.9 Dead+1.0 Wind 240 deg - No Ice 14.47 -8.20 4.74 209.88 363.09 -0.02 1.2 Dead+1.0 Wind 270 deg - No Ice 19.29 -9.47 0.00 -0.09 420.51 0.05 0.9 Dead+1.0 Wind 270 deg - No Ice 14.47 -9.47 0.00 -0.07 419.27 0.05 1.2 Dead+1.0 Wind 300 deg - No Ice 19.29 -8.20 -4.74 -210.67 364.17 0.10 0.9 Dead+1.0 Wind 300 deg - No Ice 14.47 -8.20 -4.74 -210.02 363.09 0.10 1.2 Dead+1.0 Wind 330 deg - No Ice 19.29 -4.73 -8.21 -364.82 210.23 0.13 0.9 Dead+1.0 Wind 330 deg - No Ice 14.47 -4.73 -8.21 -363.71 209.61 0.13 Dead+Wind 0 deg - Service 16.08 0.00 -3.56 -157.99 -0.05 0.04 Dead+Wind 30 deg - Service 16.08 1.78 -3.09 -136.83 -78.90 0.03 Dead+Wind 60 deg - Service 16.08 3.08 -1.78 -79.03 -136.62 0.01 Dead+Wind 90 deg - Service 16.08 3.56 0.00 -0.08 -157.75 -0.02 Dead+Wind 120 deg - Service 16.08 3.08 1.78 78.87 -136.62 -0.04 Dead+Wind 150 deg - Service 16.08 1.78 3.09 136.67 -78.90 -0.05 Dead+Wind 180 deg - Service 16.08 0.00 3.56 157.83 -0.05 -0.04 Dead+Wind 210 deg - Service 16.08 -1.78 3.09 136.67 78.79 -0.03 Dead+Wind 240 deg - Service 16.08 -3.08 1.78 78.87 136.51 -0.01 Dead+Wind 270 deg - Service 16.08 -3.56 0.00 -0.08 157.64 0.02 Dead+Wind 300 deg - Service 16.08 -3.08 -1.78 -79.03 136.51 0.04 Dead+Wind 330 deg - Service 16.08 -1.78 -3.09 -136.83 78.79 0.05 1.2 Dead+1.0 Ev+1.0 Eh 0 deg 22.61 0.00 -11.06 -546.98 -0.06 -0.00 0.9 Dead-1.0 Ev+1.0 Eh 0 deg 11.15 0.00 -11.06 -542.96 -0.05 -0.00 1.2 Dead+1.0 Ev+1.0 Eh 30 deg 22.61 5.53 -9.57 -473.71 -273.51 -0.00 0.9 Dead-1.0 Ev+1.0 Eh 30 deg 11.15 5.53 -9.57 -470.23 -271.49 -0.00 ttnnxxTToowweerr Job EDINGER AND BRISTOL (BU 845391) Page 16 of 21 TEP 326 Tryon Road Project TEP No. 229344.1130072 Date 12:45:44 07/20/25 Raleigh, NC 27603 Phone: (919) 616-6351 FAX: (919) 616-6350 Client Crown Castle Designed by TG Load Combination Vertical K Shearx K Shearz K Overturning Moment, Mx kip-ft Overturning Moment, Mz kip-ft Torque kip-ft 1.2 Dead+1.0 Ev+1.0 Eh 60 deg 22.61 9.57 -5.53 -273.54 -473.68 -0.00 0.9 Dead-1.0 Ev+1.0 Eh 60 deg 11.15 9.57 -5.53 -271.51 -470.20 -0.00 1.2 Dead+1.0 Ev+1.0 Eh 90 deg 22.61 11.06 0.00 -0.09 -546.95 -0.00 0.9 Dead-1.0 Ev+1.0 Eh 90 deg 11.15 11.06 0.00 -0.07 -542.94 -0.00 1.2 Dead+1.0 Ev+1.0 Eh 120 deg 22.61 9.57 5.53 273.35 -473.68 -0.00 0.9 Dead-1.0 Ev+1.0 Eh 120 deg 11.15 9.57 5.53 271.37 -470.20 -0.00 1.2 Dead+1.0 Ev+1.0 Eh 150 deg 22.61 5.53 9.57 473.52 -273.51 -0.00 0.9 Dead-1.0 Ev+1.0 Eh 150 deg 11.15 5.53 9.57 470.09 -271.49 -0.00 1.2 Dead+1.0 Ev+1.0 Eh 180 deg 22.61 0.00 11.06 546.79 -0.06 -0.00 0.9 Dead-1.0 Ev+1.0 Eh 180 deg 11.15 0.00 11.06 542.82 -0.05 -0.00 1.2 Dead+1.0 Ev+1.0 Eh 210 deg 22.61 -5.53 9.57 473.52 273.38 0.00 0.9 Dead-1.0 Ev+1.0 Eh 210 deg 11.15 -5.53 9.57 470.09 271.40 0.00 1.2 Dead+1.0 Ev+1.0 Eh 240 deg 22.61 -9.57 5.53 273.35 473.55 0.00 0.9 Dead-1.0 Ev+1.0 Eh 240 deg 11.15 -9.57 5.53 271.37 470.11 0.00 1.2 Dead+1.0 Ev+1.0 Eh 270 deg 22.61 -11.06 0.00 -0.09 546.82 0.00 0.9 Dead-1.0 Ev+1.0 Eh 270 deg 11.15 -11.06 0.00 -0.07 542.84 0.00 1.2 Dead+1.0 Ev+1.0 Eh 300 deg 22.61 -9.57 -5.53 -273.54 473.55 0.00 0.9 Dead-1.0 Ev+1.0 Eh 300 deg 11.15 -9.57 -5.53 -271.51 470.11 0.00 1.2 Dead+1.0 Ev+1.0 Eh 330 deg 22.61 -5.53 -9.57 -473.71 273.38 0.00 0.9 Dead-1.0 Ev+1.0 Eh 330 deg 11.15 -5.53 -9.57 -470.23 271.40 0.00 Solution Summary Load Comb. Sum of Applied Forces Sum of Reactions % Error PX K PY K PZ K PX K PY K PZ K 1 0.00 -16.08 0.00 0.00 16.08 0.00 0.000% 2 0.00 -19.29 -9.49 0.00 19.29 9.49 0.000% 3 0.00 -14.47 -9.49 0.00 14.47 9.49 0.000% 4 4.73 -19.29 -8.21 -4.73 19.29 8.21 0.000% 5 4.73 -14.47 -8.21 -4.73 14.47 8.21 0.000% 6 8.20 -19.29 -4.74 -8.20 19.29 4.74 0.000% 7 8.20 -14.47 -4.74 -8.20 14.47 4.74 0.000% 8 9.47 -19.29 0.00 -9.47 19.29 0.00 0.000% 9 9.47 -14.47 0.00 -9.47 14.47 0.00 0.000% 10 8.20 -19.29 4.74 -8.20 19.29 -4.74 0.000% 11 8.20 -14.47 4.74 -8.20 14.47 -4.74 0.000% 12 4.73 -19.29 8.21 -4.73 19.29 -8.21 0.000% 13 4.73 -14.47 8.21 -4.73 14.47 -8.21 0.000% 14 0.00 -19.29 9.49 0.00 19.29 -9.49 0.000% 15 0.00 -14.47 9.49 0.00 14.47 -9.49 0.000% 16 -4.73 -19.29 8.21 4.73 19.29 -8.21 0.000% ttnnxxTToowweerr Job EDINGER AND BRISTOL (BU 845391) Page 17 of 21 TEP 326 Tryon Road Project TEP No. 229344.1130072 Date 12:45:44 07/20/25 Raleigh, NC 27603 Phone: (919) 616-6351 FAX: (919) 616-6350 Client Crown Castle Designed by TG Load Comb. Sum of Applied Forces Sum of Reactions % Error PX K PY K PZ K PX K PY K PZ K 17 -4.73 -14.47 8.21 4.73 14.47 -8.21 0.000% 18 -8.20 -19.29 4.74 8.20 19.29 -4.74 0.000% 19 -8.20 -14.47 4.74 8.20 14.47 -4.74 0.000% 20 -9.47 -19.29 0.00 9.47 19.29 0.00 0.000% 21 -9.47 -14.47 0.00 9.47 14.47 0.00 0.000% 22 -8.20 -19.29 -4.74 8.20 19.29 4.74 0.000% 23 -8.20 -14.47 -4.74 8.20 14.47 4.74 0.000% 24 -4.73 -19.29 -8.21 4.73 19.29 8.21 0.000% 25 -4.73 -14.47 -8.21 4.73 14.47 8.21 0.000% 26 0.00 -16.08 -3.56 0.00 16.08 3.56 0.000% 27 1.78 -16.08 -3.09 -1.78 16.08 3.09 0.000% 28 3.08 -16.08 -1.78 -3.08 16.08 1.78 0.000% 29 3.56 -16.08 0.00 -3.56 16.08 0.00 0.000% 30 3.08 -16.08 1.78 -3.08 16.08 -1.78 0.000% 31 1.78 -16.08 3.09 -1.78 16.08 -3.09 0.000% 32 0.00 -16.08 3.56 0.00 16.08 -3.56 0.000% 33 -1.78 -16.08 3.09 1.78 16.08 -3.09 0.000% 34 -3.08 -16.08 1.78 3.08 16.08 -1.78 0.000% 35 -3.56 -16.08 0.00 3.56 16.08 0.00 0.000% 36 -3.08 -16.08 -1.78 3.08 16.08 1.78 0.000% 37 -1.78 -16.08 -3.09 1.78 16.08 3.09 0.000% 38 0.00 -22.61 -11.06 0.00 22.61 11.06 0.000% 39 0.00 -11.15 -11.06 0.00 11.15 11.06 0.000% 40 5.53 -22.61 -9.57 -5.53 22.61 9.57 0.000% 41 5.53 -11.15 -9.57 -5.53 11.15 9.57 0.000% 42 9.57 -22.61 -5.53 -9.57 22.61 5.53 0.000% 43 9.57 -11.15 -5.53 -9.57 11.15 5.53 0.000% 44 11.06 -22.61 0.00 -11.06 22.61 0.00 0.000% 45 11.06 -11.15 0.00 -11.06 11.15 0.00 0.000% 46 9.57 -22.61 5.53 -9.57 22.61 -5.53 0.000% 47 9.57 -11.15 5.53 -9.57 11.15 -5.53 0.000% 48 5.53 -22.61 9.57 -5.53 22.61 -9.57 0.000% 49 5.53 -11.15 9.57 -5.53 11.15 -9.57 0.000% 50 0.00 -22.61 11.06 0.00 22.61 -11.06 0.000% 51 0.00 -11.15 11.06 0.00 11.15 -11.06 0.000% 52 -5.53 -22.61 9.57 5.53 22.61 -9.57 0.000% 53 -5.53 -11.15 9.57 5.53 11.15 -9.57 0.000% 54 -9.57 -22.61 5.53 9.57 22.61 -5.53 0.000% 55 -9.57 -11.15 5.53 9.57 11.15 -5.53 0.000% 56 -11.06 -22.61 0.00 11.06 22.61 0.00 0.000% 57 -11.06 -11.15 0.00 11.06 11.15 0.00 0.000% 58 -9.57 -22.61 -5.53 9.57 22.61 5.53 0.000% 59 -9.57 -11.15 -5.53 9.57 11.15 5.53 0.000% 60 -5.53 -22.61 -9.57 5.53 22.61 9.57 0.000% 61 -5.53 -11.15 -9.57 5.53 11.15 9.57 0.000% Non-Linear Convergence Results Load Combination Converged? Number of Cycles Displacement Tolerance Force Tolerance 1 Yes 4 0.00000001 0.00000001 2 Yes 4 0.00000001 0.00001305 3 Yes 4 0.00000001 0.00000001 4 Yes 4 0.00000001 0.00005897 5 Yes 4 0.00000001 0.00003890 6 Yes 4 0.00000001 0.00005797 ttnnxxTToowweerr Job EDINGER AND BRISTOL (BU 845391) Page 18 of 21 TEP 326 Tryon Road Project TEP No. 229344.1130072 Date 12:45:44 07/20/25 Raleigh, NC 27603 Phone: (919) 616-6351 FAX: (919) 616-6350 Client Crown Castle Designed by TG 7 Yes 4 0.00000001 0.00003817 8 Yes 4 0.00000001 0.00001253 9 Yes 4 0.00000001 0.00000001 10 Yes 4 0.00000001 0.00005579 11 Yes 4 0.00000001 0.00003661 12 Yes 4 0.00000001 0.00006040 13 Yes 4 0.00000001 0.00003995 14 Yes 4 0.00000001 0.00001305 15 Yes 4 0.00000001 0.00000001 16 Yes 4 0.00000001 0.00005667 17 Yes 4 0.00000001 0.00003725 18 Yes 4 0.00000001 0.00005757 19 Yes 4 0.00000001 0.00003792 20 Yes 4 0.00000001 0.00001252 21 Yes 4 0.00000001 0.00000001 22 Yes 4 0.00000001 0.00006014 23 Yes 4 0.00000001 0.00003975 24 Yes 4 0.00000001 0.00005562 25 Yes 4 0.00000001 0.00003648 26 Yes 4 0.00000001 0.00000001 27 Yes 4 0.00000001 0.00000001 28 Yes 4 0.00000001 0.00000001 29 Yes 4 0.00000001 0.00000001 30 Yes 4 0.00000001 0.00000001 31 Yes 4 0.00000001 0.00000001 32 Yes 4 0.00000001 0.00000001 33 Yes 4 0.00000001 0.00000001 34 Yes 4 0.00000001 0.00000001 35 Yes 4 0.00000001 0.00000001 36 Yes 4 0.00000001 0.00000001 37 Yes 4 0.00000001 0.00000001 38 Yes 4 0.00000001 0.00002174 39 Yes 4 0.00000001 0.00000001 40 Yes 4 0.00000001 0.00015372 41 Yes 4 0.00000001 0.00005251 42 Yes 4 0.00000001 0.00015381 43 Yes 4 0.00000001 0.00005253 44 Yes 4 0.00000001 0.00002173 45 Yes 4 0.00000001 0.00000001 46 Yes 4 0.00000001 0.00015352 47 Yes 4 0.00000001 0.00005245 48 Yes 4 0.00000001 0.00015362 49 Yes 4 0.00000001 0.00005248 50 Yes 4 0.00000001 0.00002172 51 Yes 4 0.00000001 0.00000001 52 Yes 4 0.00000001 0.00015353 53 Yes 4 0.00000001 0.00005246 54 Yes 4 0.00000001 0.00015344 55 Yes 4 0.00000001 0.00005243 56 Yes 4 0.00000001 0.00002173 57 Yes 4 0.00000001 0.00000001 58 Yes 4 0.00000001 0.00015373 59 Yes 4 0.00000001 0.00005251 60 Yes 4 0.00000001 0.00015363 61 Yes 4 0.00000001 0.00005248 ttnnxxTToowweerr Job EDINGER AND BRISTOL (BU 845391) Page 19 of 21 TEP 326 Tryon Road Project TEP No. 229344.1130072 Date 12:45:44 07/20/25 Raleigh, NC 27603 Phone: (919) 616-6351 FAX: (919) 616-6350 Client Crown Castle Designed by TG Maximum Tower Deflections - Service Wind Section No. Elevation ft Horz. Deflection in Gov. Load Comb. Tilt ° Twist ° L1 60 - 45 1.977 26 0.2324 0.0001 L2 45 - 30 1.254 26 0.2232 0.0001 L3 30 - 0 0.612 26 0.1783 0.0001 Critical Deflections and Radius of Curvature - Service Wind Elevation ft Appurtenance Gov. Load Comb. Deflection in Tilt ° Twist ° Radius of Curvature ft 59.00 NNH4-65C-R6-V3 w/ Mount Pipe 26 1.928 0.2322 0.0001 215700 57.50 CCISeismic Tower Section 1 - 1 26 1.855 0.2320 0.0001 215700 55.00 CCISeismic miscl Safety Line 3/8 From 0 to 60 (50ft to60ft) 26 1.734 0.2315 0.0001 215700 54.50 CCISeismic 123ewireless 123-171-XX(5/16) From 0 to 59 (50ft to59ft) 26 1.710 0.2313 0.0001 196091 50.00 CCISeismic Tower Section 1 - 2 26 1.493 0.2290 0.0001 107850 48.00 APXVAALL24_43-U-NA20_TMO w/ Mount Pipe 26 1.397 0.2271 0.0001 87249 45.00 CCISeismic miscl Safety Line 3/8 From 0 to 60 (40ft to50ft) 26 1.254 0.2232 0.0001 52243 44.00 CCISeismic (3) rfs celwave HB158-21U6S24-xxM_TMO(1-5/8) From 0 to 48 (40ft to48ft) 26 1.207 0.2215 0.0001 42026 42.50 CCISeismic Tower Section 2 - 1 26 1.137 0.2186 0.0001 30691 36.00 MX08FRO665-21 w/ Mount Pipe 26 0.846 0.2011 0.0001 12676 35.00 CCISeismic Tower Section 2 - 2 26 0.804 0.1977 0.0001 11612 33.00 CCISeismic cui CU12PSM9P8XXX(1-3/8) From 0 to 36 (30ft to36ft) 26 0.723 0.1904 0.0001 10003 25.00 CCISeismic Tower Section 3 - 1 26 0.454 0.1548 0.0001 9815 15.00 CCISeismic Tower Section 3 - 2 26 0.223 0.0984 0.0000 16358 5.00 CCISeismic Tower Section 3 - 3 26 0.066 0.0337 0.0000 49073 Maximum Tower Deflections - Design Wind Section No. Elevation ft Horz. Deflection in Gov. Load Comb. Tilt ° Twist ° L1 60 - 45 5.272 2 0.6199 0.0003 L2 45 - 30 3.345 2 0.5953 0.0003 L3 30 - 0 1.632 2 0.4755 0.0002 ttnnxxTToowweerr Job EDINGER AND BRISTOL (BU 845391) Page 20 of 21 TEP 326 Tryon Road Project TEP No. 229344.1130072 Date 12:45:44 07/20/25 Raleigh, NC 27603 Phone: (919) 616-6351 FAX: (919) 616-6350 Client Crown Castle Designed by TG Critical Deflections and Radius of Curvature - Design Wind Elevation ft Appurtenance Gov. Load Comb. Deflection in Tilt ° Twist ° Radius of Curvature ft 59.00 NNH4-65C-R6-V3 w/ Mount Pipe 2 5.142 0.6195 0.0003 80800 57.50 CCISeismic Tower Section 1 - 1 2 4.948 0.6190 0.0003 80800 55.00 CCISeismic miscl Safety Line 3/8 From 0 to 60 (50ft to60ft) 2 4.625 0.6175 0.0003 80800 54.50 CCISeismic 123ewireless 123-171-XX(5/16) From 0 to 59 (50ft to59ft) 2 4.560 0.6171 0.0003 73455 50.00 CCISeismic Tower Section 1 - 2 2 3.981 0.6108 0.0003 40400 48.00 APXVAALL24_43-U-NA20_TMO w/ Mount Pipe 2 3.726 0.6059 0.0003 32683 45.00 CCISeismic miscl Safety Line 3/8 From 0 to 60 (40ft to50ft) 2 3.345 0.5953 0.0003 19571 44.00 CCISeismic (3) rfs celwave HB158-21U6S24-xxM_TMO(1-5/8) From 0 to 48 (40ft to48ft) 2 3.219 0.5907 0.0003 15744 42.50 CCISeismic Tower Section 2 - 1 2 3.032 0.5830 0.0003 11499 36.00 MX08FRO665-21 w/ Mount Pipe 2 2.255 0.5363 0.0003 4752 35.00 CCISeismic Tower Section 2 - 2 2 2.144 0.5273 0.0003 4353 33.00 CCISeismic cui CU12PSM9P8XXX(1-3/8) From 0 to 36 (30ft to36ft) 2 1.929 0.5079 0.0003 3750 25.00 CCISeismic Tower Section 3 - 1 2 1.211 0.4129 0.0002 3680 15.00 CCISeismic Tower Section 3 - 2 2 0.596 0.2623 0.0001 6133 5.00 CCISeismic Tower Section 3 - 3 2 0.177 0.0899 0.0000 18399 Compression Checks Pole Design Data Section No. Elevation ft Size L ft Lu ft Kl/r A in2 Pu K Pn K Ratio Pu Pn L1 60 - 45 (1) TP33.2x33.2x0.25 15.00 0.00 0.0 26.5247 -11.69 859.40 0.014 L2 45 - 30 (2) TP33.2x33.2x0.25 15.00 0.00 0.0 26.5247 -17.06 859.40 0.020 L3 30 - 0 (3) TP37.7x33.2x0.2813 30.00 0.00 0.0 33.8874 -22.61 1097.95 0.021 Pole Bending Design Data Section No. Elevation ft Size Mux kip-ft Mnx kip-ft Ratio Mux Mnx Muy kip-ft Mny kip-ft Ratio Muy Mny L1 60 - 45 (1) TP33.2x33.2x0.25 83.79 682.87 0.123 0.00 682.87 0.000 L2 45 - 30 (2) TP33.2x33.2x0.25 220.85 682.87 0.323 0.00 682.87 0.000 L3 30 - 0 (3) TP37.7x33.2x0.2813 547.00 987.33 0.554 0.00 987.33 0.000 ttnnxxTToowweerr Job EDINGER AND BRISTOL (BU 845391) Page 21 of 21 TEP 326 Tryon Road Project TEP No. 229344.1130072 Date 12:45:44 07/20/25 Raleigh, NC 27603 Phone: (919) 616-6351 FAX: (919) 616-6350 Client Crown Castle Designed by TG Pole Shear Design Data Section No. Elevation ft Size Actual Vu K Vn K Ratio Vu Vn Actual Tu kip-ft Tn kip-ft Ratio Tu Tn L1 60 - 45 (1) TP33.2x33.2x0.25 8.01 257.82 0.031 0.00 747.26 0.000 L2 45 - 30 (2) TP33.2x33.2x0.25 10.39 257.82 0.040 0.00 747.26 0.000 L3 30 - 0 (3) TP37.7x33.2x0.2813 11.06 329.38 0.034 0.00 1084.16 0.000 Pole Interaction Design Data Section No. Elevation ft Ratio Pu Pn Ratio Mux Mnx Ratio Muy Mny Ratio Vu Vn Ratio Tu Tn Comb. Stress Ratio Allow. Stress Ratio Criteria L1 60 - 45 (1) 0.014 0.123 0.000 0.031 0.000 0.137 1.050 L2 45 - 30 (2) 0.020 0.323 0.000 0.040 0.000 0.345 1.050 L3 30 - 0 (3) 0.021 0.554 0.000 0.034 0.000 0.576 1.050 Section Capacity Table Section No. Elevation ft Component Type Size Critical Element P K øPallow K % Capacity Pass Fail L1 60 - 45 Pole TP33.2x33.2x0.25 1 -11.69 902.37 13.1 Pass L2 45 - 30 Pole TP33.2x33.2x0.25 2 -17.06 902.37 32.8 Pass L3 30 - 0 Pole TP37.7x33.2x0.2813 3 -22.61 1152.85 54.8 Pass Summary Pole (L3) 54.8 Pass RATING = 54.8 Pass Program Version 8.3.1.2 July 20, 2025 60-ft Monopole Tower Structural Analysis Report CCI BU No 845391 TEP Project Number 229344.1130072, Order 709035, Revision 0 Page 7 tnxTower Report - version 8.3.1.2 APPENDIX B BASE LEVEL DRAWING W S N E July 20, 2025 60-ft Monopole Tower Structural Analysis Report CCI BU No 845391 TEP Project Number 229344.1130072, Order 709035, Revision 0 Page 8 tnxTower Report - version 8.3.1.2 APPENDIX C ADDITIONAL CALCULATIONS ASCE Hazards Report Address: No Address at This Location Standard:ASCE/SEI 7-16 Latitude:33.719011 Risk Category:II Longitude:-117.886903 Soil Class:D - Default (see Section 11.4.3) Elevation:48.77339979893772 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Tue Jul 15 2025 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Page 1 of 3https://ascehazardtool.org/Wed Jul 16 2025 SS : 1.29 S1 : 0.462 F a : 1.2 F v : N/A SMS : 1.548 SM1 : N/A SDS : 1.032 SD1 : N/A T L : 8 PGA : 0.55 PGA M : 0.659 F PGA : 1.2 Ie : 1 C v : 1.358 Seismic Site Soil Class: Results: Data Accessed: Date Source: D - Default (see Section 11.4.3) USGS Seismic Design Maps Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Tue Jul 15 2025 Page 2 of 3https://ascehazardtool.org/Wed Jul 16 2025 Ice Results: Data Source: Date Accessed: Ice Thickness: 0 in. Concurrent Temperature: 25 F Gust Speed 30 mph Standard ASCE/SEI 7-16, Figs. 10-2 through 10-8 Tue Jul 15 2025 Ice thicknesses on structures in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. Values provided are equivalent radial ice thicknesses due to freezing rain with concurrent 3-second gust speeds, for a 500-year mean recurrence interval, and temperatures concurrent with ice thicknesses due to freezing rain. Thicknesses for ice accretions caused by other sources shall be obtained from local meteorological studies. Ice thicknesses in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. The ASCE Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE Hazard Tool. Page 3 of 3https://ascehazardtool.org/Wed Jul 16 2025 Monopole Flange Plate Connection *TIA-222-H Section 15.5 Applied Top Plate Data Bottom Plate Data 40.25" OD x 1.25" Plate (A36; Fy=36 ksi, Fu=58 ksi)40.25" OD x 1.25" Plate (A36; Fy=36 ksi, Fu=58 ksi) Top Stiffener Data Bottom Stiffener Data N/A N/A Top Pole Data Bottom Pole Data 33.2" x 0.25" 12-sided pole (A36; Fy=36 ksi, Fu=58 ksi)33.2" x 0.25" 12-sided pole (A36; Fy=36 ksi, Fu=58 ksi) Max Load (kips)5.93 Allowable (kips)54.53 Stress Rating:10.3%Pass Top Plate Capacity Bottom Plate Capacity 4.04 (Flexural)4.04 (Flexural) 32.40 32.40 11.9%Pass 11.9%Pass 4.1%Pass 4.1%Pass Allowable Stress (ksi):Allowable Stress (ksi): Stress Rating:Stress Rating: Tension Side Stress Rating:Tension Side Stress Rating: Analysis Results Bolt Capacity Max Stress (ksi):Max Stress (ksi): TIA-222 Revision H Top Plate - External Bottom Plate - External Connection Properties Bolt Data (16) 1" ø bolts (A325 N; Fy=92 ksi, Fu=120 ksi) on 37.75" BC Order # 709035 Rev. 0 Axial Force (kips) 11.69 Axial Force (kips) 0.00 Shear Force (kips) 8.01 Shear Force (kips) 0.00 Elevation = 45 ft. BU # 845391 Applied Loads Applied Loads to Bridge Stiffeners Site Name Edinger and Bristol Moment (kip-ft) 83.79 Moment (kip-ft) 0.00 Show image? Plate Dia. Shaft Dia. Pole Shape Plate Type: Plate Geometry: Plate Quantity Plate Dia. 2 Shaft Dia. 2 Show image? Plate Dia. Shaft Dia. Pole Shape Plate Type: Plate Geometry: Plate Quantity Plate Dia. 2 Shaft Dia. 2 Analysis Date: 7/20/2025CCIplate - Version 5.1.1 Monopole Flange Plate Connection *TIA-222-H Section 15.5 Applied Top Plate Data Bottom Plate Data 40.25" OD x 1.25" Plate (A36; Fy=36 ksi, Fu=58 ksi)40.25" OD x 1.25" Plate (A36; Fy=36 ksi, Fu=58 ksi) Top Stiffener Data Bottom Stiffener Data N/A N/A Top Pole Data Bottom Pole Data 33.2" x 0.25" 12-sided pole (A36; Fy=36 ksi, Fu=58 ksi)33.2" x 0.2813" 12-sided pole (A36; Fy=36 ksi, Fu=58 ksi) Max Load (kips)16.48 Allowable (kips)54.53 Stress Rating:28.8%Pass Top Plate Capacity Bottom Plate Capacity 10.16 (Flexural)10.16 (Flexural) 32.40 32.40 29.9%Pass 29.9%Pass 11.4%Pass 11.4%Pass Allowable Stress (ksi):Allowable Stress (ksi): Stress Rating:Stress Rating: Tension Side Stress Rating:Tension Side Stress Rating: Analysis Results Bolt Capacity Max Stress (ksi):Max Stress (ksi): TIA-222 Revision H Top Plate - External Bottom Plate - External Connection Properties Bolt Data (16) 1" ø bolts (A325 N; Fy=92 ksi, Fu=120 ksi) on 37.75" BC Order # 709035 Rev. 0 Axial Force (kips) 17.06 Axial Force (kips) 0.00 Shear Force (kips) 10.39 Shear Force (kips) 0.00 Elevation = 30 ft. BU # 845391 Applied Loads Applied Loads to Bridge Stiffeners Site Name Edinger and Bristol Moment (kip-ft) 220.85 Moment (kip-ft) 0.00 Show image? Plate Dia. Shaft Dia. Pole Shape Plate Type: Plate Geometry: Plate Quantity Plate Dia. 2 Shaft Dia. 2 Analysis Date: 7/20/2025CCIplate - Version 5.1.1 Monopole Base Plate Connection *TIA-222-H Section 15.5 Applied #VALUE! Anchor Rod Data Anchor Rod Summary (units of kips, kip-in) (4) 2-1/4" ø bolts (A615-75 N; Fy=75 ksi, Fu=100 ksi) on 45.42" BC Pu_t = 106.37 φPn_t = 243.75 Stress Rating Vu = 2.25 φVn = 149.1 41.6% Base Plate Data Mu = n/a φMn = n/a Pass 44.15" W x 2.625" Plate (A36; Fy=36 ksi, Fu=58 ksi); Clip: 3 in Base Plate Summary Stiffener Data Max Stress (ksi):10.5 (Flexural) N/A Allowable Stress (ksi):32.4 Stress Rating:30.9%Pass Pole Data 37.7" x 0.2813" 12-sided pole (A36; Fy=36 ksi, Fu=58 ksi) Analysis ResultsConnection Properties Iar (in) 1.5 Moment (kip-ft) 421.00 Axial Force (kips) 19.00 Shear Force (kips) 9.00 Moment (kip-ft) Axial Force (kips) Shear Force (kips) 0.00 BU # 845391 Applied Loads Site Name Edinger and Bristol Order # 709035 Rev. 0 Analysis Considerations Site Info TIA-222 Revision H Grout Considered:No 19.00 9.00 Adjusted Pole Reactions Analysis Date: 7/20/2025CCIplate - Version 5.1.1 Report File: TIA-222 Revison: Tower Type:Check Pier Capacity only at location of Max Moment?No Location: Soil Lateral Check Compression Uplift Comp.Uplift 5.33 - 547 6.64 - 23 595.84 - 11 19.1%- Soil Vertical Check Compression Uplift Go to Soil Calculations 116.63 - 3 ksi 213.53 - 60 ksi 59.80 - 60 ksi 330.16 - 82.80 - 23.9%- 21 ft Reinforced Concrete Flexure Compression Uplift 0.5 ft 5.27 - 595.82 - 2277.59 - 5 ft 24.9%- 27 16 Reinforced Concrete Shear Compression Uplift 10 17.78 - 54 in 44.51 - 4 378.65 - Tie Spacing Requirements Not Met 33.25 in 11.2%- Shear-Friction Methodology is Applied in *Rating per TIA-222-H Section 15.5 10 # of Layers 5 121 FALSE 1 0 3 3 110 150 0 0 0.000 0.000 0.00 0.00 FALSE 2 3 4 1 120 150 1 0 0.550 0.550 0.00 0.00 FALSE 3 4 10 6 120 150 1 0 0.550 0.550 0.55 0.55 FALSE 4 10 16 6 63 87.6 2 0 1.100 1.100 1.10 1.10 FALSE 5 16 21 5 63 87.6 2 0 1.100 1.100 0.00 0.00 14.5 Shear Force (kips)Rating* Utilize Shear-Friction Methodology: Check Limitation Override Critical Depth: Check Shear along Depth of Pier: N/A Design Options Input Effective Depths (else Actual): Apply TIA-222-H Section 15.5:Monopole Analysis Results Applied Loads Dv=0 (ft from TOC) Soil Safety FactorMoment (kip-ft) Max Moment (kip-ft)Axial Force (kips) Consider non-tapered moment capacity: Drilled Pier Foundation BU # :845391 Edinger and BristolSite Name: 709035 Rev. 0Order Number: H Rebar Size Critical Depth (ft from TOC) Rebar Cage Diameter Critical Shear (kip) Critical Shear CapacityTie Size Rating*Tie Spacing Rebar 2, Fy Override (ksi) Rebar 3, Fy Override (ksi) Material Properties Skin Friction (kips) Concrete Strength, f'c:End Bearing (kips) Rebar Strength, Fy:Weight of Concrete (kips) Tie Yield Strength, Fyt:Total Capacity (kips) Axial (kips) Pier Design Data Rating* Depth Ext. Above Grade Critical Depth (ft from TOC) Critical Moment (kip-ft)Pier Section 1 From 0.5' above grade to 21' below grade Critical Moment Capacity Pier Diameter Rating* Rebar Quantity Rebar Quantity Structural Foundation Rating*Rebar Size 24.9% Rebar Cage Diameter Soil Interaction Rating*23.9% Layer Soil TypeTop (ft) Cohesionless Soil Profile Groundwater Depth SPT Blow Count Ult. Gross Bearing Capacity (ksf) Ultimate Skin Friction Uplift Override (ksf) Ultimate Skin Friction Comp Override (ksf) Calculated Ultimate Skin Friction Uplift (ksf) Calculated Ultimate Skin Friction Comp (ksf) Angle of Friction (degrees) γconcrete (pcf) γsoil (pcf) Cohesion (ksf)Bottom (ft)Thickness (ft) Cohesive Cohesive Cohesive Cohesive Rebar & Pier Options Embedded Pole Inputs Belled Pier Inputs Version 6.4.7 BU:845391 Structure:A WO:2408155 Order:709035 Rev:0 Decimal Degrees Deg Min Sec ###Lat:33.719011 +33 43 8.44 ###Long:-117.886903 -117 53 12.85 Seismic Design Code:TIA-222-H-1 ###Site Soil:D (Default)Default Risk Category:II ###USGS Seismic Reference SS:1.2900 g ###S1:0.4620 g TL:8 s 1 Importance Factor, Ie:1 Acceleration-based site coefficient, Fa:1.2000 Velocity-based site coefficient, Fv:1.8380 Design spectral response acceleration short period, SDS:1.0320 g Design spectral response acceleration 1 s period, SD1:0.5661 g Ts:0.5486 s Seismic Design Category Based on SDS:D Seismic Design Category Based on SD1:D Seismic Design Category Based on S1:N/A Controlling Seismic Design Category:D Location Code and Site Parameters Seismic Design Category Determination CCISeismic 5.0.2 Page 1 Analysis Date: 7/20/2025 BU:845391 Structure:A WO:2408155 Order:709035 Rev:0 Tower Type:Tapered Monopole Height, h:60 ft ###Effective Seismic Weight, W:16.07 kips Amplification Factor, As:1.0 2.7.8.1 ###Response Modification Factor, R:1.5 ###0.717 Fundamental Period, T:0.7170 s Seismic Response Coefficient, Cs 0.6880 Table 2-12 Note 3 N/A Seismic Response Coefficient Max 1, Csmax N/A Seismic Response Coefficient Max 2, Csmax N/A 0.0454 Seismic Response Coefficient Min 1, Csmin 0.0454 2.7.7.1.1 Seismic Response Coefficient Min 2, Csmin N/A 2.7.7.1.1 Controlling Seismic Response Coefficient, Csc 0.6880 Seismic Base Shear, V 11.056 kips 2.7.7.1.1 Period Related Exponent, k:1.109 Sum of wihi k 996.56 ### Tower Details Seismic Base Shear Vertical Distribution Factors CCISeismic 5.0.2 Page 2 Analysis Date: 7/20/2025 Section Number Length Top Height Mid Height, hx Section Weight, wx wxhx k Cvx Fxh Fxv 1 - 1 5.00 60.00 57.50 0.4506 40.22 0.0404 0.4462 0.0930 1 - 2 10.00 55.00 50.00 0.9013 68.89 0.0691 0.7643 0.1860 2 - 1 5.00 45.00 42.50 0.4506 28.77 0.0289 0.3192 0.0930 2 - 2 10.00 40.00 35.00 0.9013 46.39 0.0466 0.5147 0.1860 3 - 1 10.00 30.00 25.00 1.0361 36.73 0.0369 0.4075 0.2138 3 - 2 10.00 20.00 15.00 1.0822 21.78 0.0219 0.2416 0.2234 3 - 3 10.00 10.00 5.00 1.1284 6.72 0.0067 0.0745 0.2329 Sum 5.9505 249.50 Tower Section Loads CCISeismic 5.0.2 Page 3 Analysis Date: 7/20/2025 Name hx wx wxhx k Cvx Fxh Fxv commscope_cfd NNH4-65C-R6-V3 w/ Mount Pipe 59.00 0.1586 14.57 0.0146 0.1616 0.0327 commscope_cfd NNH4-65C-R6-V3 w/ Mount Pipe 59.00 0.1586 14.57 0.0146 0.1616 0.0327 commscope_cfd NNH4-65C-R6-V3 w/ Mount Pipe 59.00 0.1586 14.57 0.0146 0.1616 0.0327 ericsson_cfd AIR 6419 B77G_2024 w/ Mount Pipe 59.00 0.0773 7.09 0.0071 0.0787 0.0159 ericsson_cfd AIR 6419 B77G_2024 w/ Mount Pipe 59.00 0.0773 7.09 0.0071 0.0787 0.0159 ericsson_cfd AIR 6419 B77G_2024 w/ Mount Pipe 59.00 0.0773 7.09 0.0071 0.0787 0.0159 ericsson_cfd AIR 6449 B77D_CCIV3 w/ Mount Pipe 59.00 0.1098 10.08 0.0101 0.1118 0.0227 ericsson_cfd AIR 6449 B77D_CCIV3 w/ Mount Pipe 59.00 0.1098 10.08 0.0101 0.1118 0.0227 ericsson_cfd AIR 6449 B77D_CCIV3 w/ Mount Pipe 59.00 0.1098 10.08 0.0101 0.1118 0.0227 kathrein_cfd 800 10866K w/ Mount Pipe 59.00 0.1145 10.52 0.0106 0.1167 0.0236 kathrein_cfd 800 10866K w/ Mount Pipe 59.00 0.1145 10.52 0.0106 0.1167 0.0236 kathrein_cfd 800 10866K w/ Mount Pipe 59.00 0.1145 10.52 0.0106 0.1167 0.0236 kathrein_cfd 80010966 w/ Mount Pipe 59.00 0.1586 14.57 0.0146 0.1616 0.0327 kathrein_cfd 80010966 w/ Mount Pipe 59.00 0.1586 14.57 0.0146 0.1616 0.0327 kathrein_cfd 80010966 w/ Mount Pipe 59.00 0.1586 14.57 0.0146 0.1616 0.0327 ericsson RRUS 4449 B5/B12 59.00 0.0700 6.43 0.0065 0.0713 0.0144 ericsson RRUS 4449 B5/B12 59.00 0.0700 6.43 0.0065 0.0713 0.0144 ericsson RRUS 4449 B5/B12 59.00 0.0700 6.43 0.0065 0.0713 0.0144 ericsson RRUS 8843 B2/B66A_CCIV2 59.00 0.0800 7.35 0.0074 0.0815 0.0165 ericsson RRUS 8843 B2/B66A_CCIV2 59.00 0.0800 7.35 0.0074 0.0815 0.0165 ericsson RRUS 8843 B2/B66A_CCIV2 59.00 0.0800 7.35 0.0074 0.0815 0.0165 raycap DC6-48-60-18-8F_070710 59.00 0.0200 1.84 0.0018 0.0204 0.0041 raycap DC6-48-60-18-8F_070710 59.00 0.0200 1.84 0.0018 0.0204 0.0041 raycap DC6-48-60-18-8F_070710 59.00 0.0200 1.84 0.0018 0.0204 0.0041 ericsson RRUS 4478 B14_CCIV2 59.00 0.0600 5.51 0.0055 0.0611 0.0124 ericsson RRUS 4478 B14_CCIV2 59.00 0.0600 5.51 0.0055 0.0611 0.0124 ericsson RRUS 4478 B14_CCIV2 59.00 0.0600 5.51 0.0055 0.0611 0.0124 ericsson RRUS 32 B30 59.00 0.0500 4.59 0.0046 0.0509 0.0103 ericsson RRUS 32 B30 59.00 0.0500 4.59 0.0046 0.0509 0.0103 ericsson RRUS 32 B30 59.00 0.0500 4.59 0.0046 0.0509 0.0103 2.9" Dia. x 6-ft Mount Pipe 59.00 0.0300 2.75 0.0028 0.0306 0.0062 2.9" Dia. x 6-ft Mount Pipe 59.00 0.0300 2.75 0.0028 0.0306 0.0062 2.9" Dia. x 6-ft Mount Pipe 59.00 0.0300 2.75 0.0028 0.0306 0.0062 tower mounts (cci) Pipe Mount [PM 601-3]59.00 0.1950 17.91 0.0180 0.1987 0.0402 tower mounts (cci) Sector Mount [SM 502-3]59.00 1.6731 153.64 0.1542 1.7046 0.3453 rfs celwave_cfd APXVAALL24_43-U-NA20_TMO w/ Mount Pipe 48.00 0.1828 13.35 0.0134 0.1481 0.0377 rfs celwave_cfd APXVAALL24_43-U-NA20_TMO w/ Mount Pipe 48.00 0.1828 13.35 0.0134 0.1481 0.0377 rfs celwave_cfd APXVAALL24_43-U-NA20_TMO w/ Mount Pipe 48.00 0.1828 13.35 0.0134 0.1481 0.0377 ericsson_cfd AIR6449 B41_T-MOBILE w/ Mount Pipe 48.00 0.1284 9.38 0.0094 0.1040 0.0265 ericsson_cfd AIR6449 B41_T-MOBILE w/ Mount Pipe 48.00 0.1284 9.38 0.0094 0.1040 0.0265 ericsson_cfd AIR6449 B41_T-MOBILE w/ Mount Pipe 48.00 0.1284 9.38 0.0094 0.1040 0.0265 ericsson RADIO 4480 B71_TMO 48.00 0.0900 6.58 0.0066 0.0729 0.0186 ericsson RADIO 4480 B71_TMO 48.00 0.0900 6.58 0.0066 0.0729 0.0186 ericsson RADIO 4480 B71_TMO 48.00 0.0900 6.58 0.0066 0.0729 0.0186 ericsson RADIO 4460 B2/B25 B66_TMO 48.00 0.1100 8.04 0.0081 0.0892 0.0227 ericsson RADIO 4460 B2/B25 B66_TMO 48.00 0.1100 8.04 0.0081 0.0892 0.0227 ericsson RADIO 4460 B2/B25 B66_TMO 48.00 0.1100 8.04 0.0081 0.0892 0.0227 (2) tower mounts (cci) T-Arm Mount [TA 702-3]48.00 0.6780 49.53 0.0497 0.5495 0.1399 jma wireless_cfd MX08FRO665-21 w/ Mount Pipe 36.00 0.1081 5.74 0.0058 0.0637 0.0223 jma wireless_cfd MX08FRO665-21 w/ Mount Pipe 36.00 0.1081 5.74 0.0058 0.0637 0.0223 jma wireless_cfd MX08FRO665-21 w/ Mount Pipe 36.00 0.1081 5.74 0.0058 0.0637 0.0223 samsung telecommunications RF4451d-70A 36.00 0.0600 3.19 0.0032 0.0354 0.0124 samsung telecommunications RF4451d-70A 36.00 0.0600 3.19 0.0032 0.0354 0.0124 samsung telecommunications RF4451d-70A 36.00 0.0600 3.19 0.0032 0.0354 0.0124 samsung telecommunications RF4450t-71A 36.00 0.0900 4.78 0.0048 0.0530 0.0186 samsung telecommunications RF4450t-71A 36.00 0.0900 4.78 0.0048 0.0530 0.0186 samsung telecommunications RF4450t-71A 36.00 0.0900 4.78 0.0048 0.0530 0.0186 raycap RDIDC-9181-PF-48 36.00 0.0200 1.06 0.0011 0.0118 0.0041 (2) mounts 2.4" Dia x 8-ft Mount Pipe 36.00 0.0600 3.19 0.0032 0.0354 0.0124 (2) mounts 2.4" Dia x 8-ft Mount Pipe 36.00 0.0600 3.19 0.0032 0.0354 0.0124 (2) mounts 2.4" Dia x 8-ft Mount Pipe 36.00 0.0600 3.19 0.0032 0.0354 0.0124 tower mounts Commscope MC-K6MHDX-9-96 (3)36.00 1.1920 63.30 0.0635 0.7023 0.2460 Sum 9.0322 704.03 Discrete Loads CCISeismic 5.0.2 Page 4 Analysis Date: 7/20/2025 Name Start Height End Height hx wx wxhx k Cvx Fxh Fxv miscl Safety Line 3/8 From 0 to 60 50.00 60.00 55.00 0.0022 0.19 0.0002 0.0021 0.0005 miscl Safety Line 3/8 From 0 to 60 40.00 50.00 45.00 0.0022 0.15 0.0002 0.0017 0.0005 miscl Safety Line 3/8 From 0 to 60 30.00 40.00 35.00 0.0022 0.11 0.0001 0.0013 0.0005 miscl Safety Line 3/8 From 0 to 60 20.00 30.00 25.00 0.0022 0.08 0.0001 0.0009 0.0005 miscl Safety Line 3/8 From 0 to 60 10.00 20.00 15.00 0.0022 0.04 0.0000 0.0005 0.0005 miscl Safety Line 3/8 From 0 to 60 0.00 10.00 5.00 0.0022 0.01 0.0000 0.0001 0.0005 miscl Step Pegs (5/8" SR) 7-in. w/30" step From 0 to 60 50.00 60.00 55.00 0.0049 0.41 0.0004 0.0046 0.0010 miscl Step Pegs (5/8" SR) 7-in. w/30" step From 0 to 60 40.00 50.00 45.00 0.0049 0.33 0.0003 0.0037 0.0010 miscl Step Pegs (5/8" SR) 7-in. w/30" step From 0 to 60 30.00 40.00 35.00 0.0049 0.25 0.0003 0.0028 0.0010 miscl Step Pegs (5/8" SR) 7-in. w/30" step From 0 to 60 20.00 30.00 25.00 0.0049 0.17 0.0002 0.0019 0.0010 miscl Step Pegs (5/8" SR) 7-in. w/30" step From 0 to 60 10.00 20.00 15.00 0.0049 0.10 0.0001 0.0011 0.0010 miscl Step Pegs (5/8" SR) 7-in. w/30" step From 0 to 60 0.00 10.00 5.00 0.0049 0.03 0.0000 0.0003 0.0010 123ewireless 123-171-XX(5/16) From 0 to 59 50.00 59.00 54.50 0.0007 0.06 0.0001 0.0006 0.0001 123ewireless 123-171-XX(5/16) From 0 to 59 40.00 50.00 45.00 0.0008 0.05 0.0001 0.0006 0.0002 123ewireless 123-171-XX(5/16) From 0 to 59 30.00 40.00 35.00 0.0008 0.04 0.0000 0.0004 0.0002 123ewireless 123-171-XX(5/16) From 0 to 59 20.00 30.00 25.00 0.0008 0.03 0.0000 0.0003 0.0002 123ewireless 123-171-XX(5/16) From 0 to 59 10.00 20.00 15.00 0.0008 0.02 0.0000 0.0002 0.0002 123ewireless 123-171-XX(5/16) From 0 to 59 0.00 10.00 5.00 0.0008 0.00 0.0000 0.0000 0.0002 (3) rosenberger leoni FB-L98B-034-XXXXXX(3/8) From 0 to 59 50.00 59.00 54.50 0.0014 0.11 0.0001 0.0013 0.0003 (3) rosenberger leoni FB-L98B-034-XXXXXX(3/8) From 0 to 59 40.00 50.00 45.00 0.0015 0.10 0.0001 0.0011 0.0003 (3) rosenberger leoni FB-L98B-034-XXXXXX(3/8) From 0 to 59 30.00 40.00 35.00 0.0015 0.08 0.0001 0.0009 0.0003 (3) rosenberger leoni FB-L98B-034-XXXXXX(3/8) From 0 to 59 20.00 30.00 25.00 0.0015 0.05 0.0001 0.0006 0.0003 (3) rosenberger leoni FB-L98B-034-XXXXXX(3/8) From 0 to 59 10.00 20.00 15.00 0.0015 0.03 0.0000 0.0003 0.0003 (3) rosenberger leoni FB-L98B-034-XXXXXX(3/8) From 0 to 59 0.00 10.00 5.00 0.0015 0.01 0.0000 0.0001 0.0003 (6) rosenberger leoni WR-VG86ST-BRD(3/4) From 0 to 59 50.00 59.00 54.50 0.0315 2.65 0.0027 0.0294 0.0065 (6) rosenberger leoni WR-VG86ST-BRD(3/4) From 0 to 59 40.00 50.00 45.00 0.0350 2.38 0.0024 0.0264 0.0072 (6) rosenberger leoni WR-VG86ST-BRD(3/4) From 0 to 59 30.00 40.00 35.00 0.0350 1.80 0.0018 0.0200 0.0072 (6) rosenberger leoni WR-VG86ST-BRD(3/4) From 0 to 59 20.00 30.00 25.00 0.0350 1.24 0.0012 0.0138 0.0072 (6) rosenberger leoni WR-VG86ST-BRD(3/4) From 0 to 59 10.00 20.00 15.00 0.0350 0.71 0.0007 0.0078 0.0072 (6) rosenberger leoni WR-VG86ST-BRD(3/4) From 0 to 59 0.00 10.00 5.00 0.0350 0.21 0.0002 0.0023 0.0072 rosenberger leoni WR-VG86ST-BRD(3/4) From 0 to 59 50.00 59.00 54.50 0.0053 0.44 0.0004 0.0049 0.0011 rosenberger leoni WR-VG86ST-BRD(3/4) From 0 to 59 40.00 50.00 45.00 0.0058 0.40 0.0004 0.0044 0.0012 rosenberger leoni WR-VG86ST-BRD(3/4) From 0 to 59 30.00 40.00 35.00 0.0058 0.30 0.0003 0.0033 0.0012 rosenberger leoni WR-VG86ST-BRD(3/4) From 0 to 59 20.00 30.00 25.00 0.0058 0.21 0.0002 0.0023 0.0012 rosenberger leoni WR-VG86ST-BRD(3/4) From 0 to 59 10.00 20.00 15.00 0.0058 0.12 0.0001 0.0013 0.0012 rosenberger leoni WR-VG86ST-BRD(3/4) From 0 to 59 0.00 10.00 5.00 0.0058 0.03 0.0000 0.0004 0.0012 andrew LDF5-50A(7/8) From 0 to 59 50.00 59.00 54.50 0.0030 0.25 0.0003 0.0028 0.0006 andrew LDF5-50A(7/8) From 0 to 59 40.00 50.00 45.00 0.0033 0.22 0.0002 0.0025 0.0007 andrew LDF5-50A(7/8) From 0 to 59 30.00 40.00 35.00 0.0033 0.17 0.0002 0.0019 0.0007 andrew LDF5-50A(7/8) From 0 to 59 20.00 30.00 25.00 0.0033 0.12 0.0001 0.0013 0.0007 andrew LDF5-50A(7/8) From 0 to 59 10.00 20.00 15.00 0.0033 0.07 0.0001 0.0007 0.0007 andrew LDF5-50A(7/8) From 0 to 59 0.00 10.00 5.00 0.0033 0.02 0.0000 0.0002 0.0007 (17) andrew LDF5-50A(7/8) From 0 to 59 50.00 59.00 54.50 0.0505 4.25 0.0043 0.0471 0.0104 (17) andrew LDF5-50A(7/8) From 0 to 59 40.00 50.00 45.00 0.0561 3.82 0.0038 0.0423 0.0116 (17) andrew LDF5-50A(7/8) From 0 to 59 30.00 40.00 35.00 0.0561 2.89 0.0029 0.0320 0.0116 (17) andrew LDF5-50A(7/8) From 0 to 59 20.00 30.00 25.00 0.0561 1.99 0.0020 0.0221 0.0116 (17) andrew LDF5-50A(7/8) From 0 to 59 10.00 20.00 15.00 0.0561 1.13 0.0011 0.0125 0.0116 (17) andrew LDF5-50A(7/8) From 0 to 59 0.00 10.00 5.00 0.0561 0.33 0.0003 0.0037 0.0116 miscl 2" Flexible Conduit From 0 to 59 50.00 59.00 54.50 0.0031 0.26 0.0003 0.0029 0.0006 miscl 2" Flexible Conduit From 0 to 59 40.00 50.00 45.00 0.0034 0.23 0.0002 0.0026 0.0007 miscl 2" Flexible Conduit From 0 to 59 30.00 40.00 35.00 0.0034 0.18 0.0002 0.0019 0.0007 miscl 2" Flexible Conduit From 0 to 59 20.00 30.00 25.00 0.0034 0.12 0.0001 0.0013 0.0007 miscl 2" Flexible Conduit From 0 to 59 10.00 20.00 15.00 0.0034 0.07 0.0001 0.0008 0.0007 miscl 2" Flexible Conduit From 0 to 59 0.00 10.00 5.00 0.0034 0.02 0.0000 0.0002 0.0007 (3) rfs celwave HB158-21U6S24-xxM_TMO(1-5/8) From 0 to 48 40.00 48.00 44.00 0.0600 3.98 0.0040 0.0442 0.0124 (3) rfs celwave HB158-21U6S24-xxM_TMO(1-5/8) From 0 to 48 30.00 40.00 35.00 0.0750 3.86 0.0039 0.0428 0.0155 (3) rfs celwave HB158-21U6S24-xxM_TMO(1-5/8) From 0 to 48 20.00 30.00 25.00 0.0750 2.66 0.0027 0.0295 0.0155 (3) rfs celwave HB158-21U6S24-xxM_TMO(1-5/8) From 0 to 48 10.00 20.00 15.00 0.0750 1.51 0.0015 0.0167 0.0155 (3) rfs celwave HB158-21U6S24-xxM_TMO(1-5/8) From 0 to 48 0.00 10.00 5.00 0.0750 0.45 0.0004 0.0050 0.0155 cui CU12PSM9P8XXX(1-3/8) From 0 to 36 30.00 36.00 33.00 0.0100 0.48 0.0005 0.0053 0.0021 cui CU12PSM9P8XXX(1-3/8) From 0 to 36 20.00 30.00 25.00 0.0166 0.59 0.0006 0.0065 0.0034 cui CU12PSM9P8XXX(1-3/8) From 0 to 36 10.00 20.00 15.00 0.0166 0.33 0.0003 0.0037 0.0034 cui CU12PSM9P8XXX(1-3/8) From 0 to 36 0.00 10.00 5.00 0.0166 0.10 0.0001 0.0011 0.0034 Sum 1.0872 43.03 Linear Loads CCISeismic 5.0.2 Page 5 Analysis Date: 7/20/2025 Monopole Base Plate Connection - Seismic *TIA-222-H Section 15.5 Applied *1.5 Overstrength Factor Applied #VALUE! Anchor Rod Data Anchor Rod Summary (units of kips, kip-in) (4) 2-1/4" ø bolts (A615-75 N; Fy=75 ksi, Fu=100 ksi) on 45.42" BC Pu_t = 210.81 φPn_t = 243.75 Stress Rating Vu = 4.13 φVn = 149.1 82.4% Base Plate Data Mu = n/a φMn = n/a Pass 44.15" W x 2.625" Plate (A36; Fy=36 ksi, Fu=58 ksi); Clip: 3 in Base Plate Summary Stiffener Data Max Stress (ksi):13.6 (Flexural) N/A Allowable Stress (ksi):32.4 Stress Rating:40.0%Pass Pole Data 37.7" x 0.2813" 12-sided pole (A36; Fy=36 ksi, Fu=58 ksi) Site Info BU # 845391 Site Name Edinger and Bristol Moment (kip-ft) 547.00 Order # 709035 Rev. 0 Analysis Considerations TIA-222 Revision H Grout Considered:No Iar (in) 1.5 Applied Loads Analysis Results Axial Force (kips) 23.00 Shear Force (kips) 11.00 Adjusted Pole Reactions Moment (kip-ft) 0.00 Axial Force (kips) 23.00 Shear Force (kips) 11.00 Connection Properties Show image? Plate Dia. Shaft Dia. Pole Shape Plate Type: Plate Geometry: Plate Quantity Plate Dia. 2 Shaft Dia. 2 Analysis Date: 7/20/2025CCIplate - Version 5.1.1