SITE PLAN - SCALE = 1/16" = 1'-0"
PAGE
REV: C 2/6/2026
MARY MACALA
1301 MAR LES W, SANTA ANA,
CA, 92706
PROJECT NUMBER:
109R-301MACA PR-3004210689
SHEET
DESIGNER:
JOANNA MARIE PALMA
CUSTOMER RESIDENCE:
TEL. (714) 309-7546
APN: 198-071-46
(415) 580-6920 ex3
#ESTAMP#SSTAMP
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
SITE PLAN
MAIN PANEL
SERVICE ENTRANCESE
MP
SUB-PANELSP
LEGEND SCALE: NTS
NOTE: NOT ALL ITEMS IN LEGEND
WILL APPEAR IN SITE PLAN
ENERGY STORAGE
SYSTEM (ESS)
GP GENERATION PANEL
INVERTER(S)
AC DISCONNECT(S)
DC DISCONNECT(S)
INTERIOR EQUIPMENT
SHOWN AS DASHEDINV
AC
DC
METER ADAPTERMA BATTERY
BP BACKUP LOADS PANEL MD MICROGRID
INTERCONNECT DEVICE
PV LOAD CENTERLC METER ADAPTER
CONTROLLER
EXTERNAL RAPID
SHUTDOWN SWITCHRSD
APB FRANKLIN
APBOX
CB IQ COMBINER BOX MAC
NOTES:
·RESIDENCE DOES NOT CONTAIN ACTIVE FIRE
SPRINKLERS.
ARRAY DETAILS:
·TOTAL ROOF SURFACE AREA: 3505 SQFT.
·TOTAL PV ARRAY AREA: 503.8 SQ FT.
·PERCENTAGE PV COVERAGE:
(TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE
AREA) * 100 = 14.4%
RAIL
STANDOFFS &
FOOTINGS
SOLAR
MODULES
ARRAY
PITCH
PV AREA
(SQFT)
AR-01 23° 188.92
AR-02 23° 314.8790°
TRUE
AZIM
MAG
AZIM
168°180°
78°
ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS
IN ACCORDANCE WITH R328.4. ESS UNITS SHALL BE
SEPARATED FROM EACH OTHER BY NOT LESS THAN 3 FEET
EXCEPT WHERE SMALLER SEPARATION DISTANCES ARE
DOCUMENTED TO BE ADEQUATE BASED ON LARGE/SCALE
FIRE TESTING.
NOTE: ROOFTOP MODULE LEVEL RAPID
SHUTDOWN DEVICE INSTALLED PER CEC
690.12
(E) RESIDENCE
(N) ARRAY AR-01(N) ARRAY AR-02(E) FENCE
MA
R
L
E
S
W
(E) GATE
FIRE SETBACKS
(18" TYP)
ROOF PATHWAYS
(3' TYP)
(E) SHEDROOF PATHWAYS
(3' TYP)
(E) DRIVEWAY
MP
SE
INV ACINV
A
B B
B B
B B
C C
C C
C C
C C
B
A A A A
AAAA
LC
RDS
PV-2.0
AC
C
Signed: 2/6/2026
PL
PL
PL
PL PL PL PL PL
PL
PL
PL
PLPLPLPLPL
SITE PLAN - SCALE = 1/16" = 1'-0"
PAGE
REV: D 2/20/2026
MARY MACALA
1301 MAR LES W, SANTA ANA,
CA, 92706
PROJECT NUMBER:
109R-301MACA PR-3004210689
SHEET
DESIGNER:
JOANNA MARIE PALMA
CUSTOMER RESIDENCE:
TEL. (714) 309-7546
APN: 198-071-46
(415) 580-6920 ex3
#ESTAMP#SSTAMP
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
SITE PLAN
MAIN PANEL
SERVICE ENTRANCESE
MP
SUB-PANELSP
LEGEND SCALE: NTS
NOTE: NOT ALL ITEMS IN LEGEND
WILL APPEAR IN SITE PLAN
ENERGY STORAGE
SYSTEM (ESS)
GP GENERATION PANEL
INVERTER(S)
AC DISCONNECT(S)
DC DISCONNECT(S)
INTERIOR EQUIPMENT
SHOWN AS DASHEDINV
AC
DC
METER ADAPTERMA BATTERY
BP BACKUP LOADS PANEL MD MICROGRID
INTERCONNECT DEVICE
PV LOAD CENTERLC METER ADAPTER
CONTROLLER
EXTERNAL RAPID
SHUTDOWN SWITCHRSD
APB FRANKLIN
APBOX
CB IQ COMBINER BOX MAC
NOTES:
·RESIDENCE DOES NOT CONTAIN ACTIVE FIRE
SPRINKLERS.
ARRAY DETAILS:
·TOTAL ROOF SURFACE AREA: 3505 SQFT.
·TOTAL PV ARRAY AREA: 503.8 SQ FT.
·PERCENTAGE PV COVERAGE:
(TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE
AREA) * 100 = 14.4%
RAIL
STANDOFFS &
FOOTINGS
SOLAR
MODULES
ARRAY
PITCH
PV AREA
(SQFT)
AR-01 23° 188.92
AR-02 23° 314.8790°
TRUE
AZIM
MAG
AZIM
168°180°
78°
ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS
IN ACCORDANCE WITH R328.4. ESS UNITS SHALL BE
SEPARATED FROM EACH OTHER BY NOT LESS THAN 3 FEET
EXCEPT WHERE SMALLER SEPARATION DISTANCES ARE
DOCUMENTED TO BE ADEQUATE BASED ON LARGE/SCALE
FIRE TESTING.
NOTE: ROOFTOP MODULE LEVEL RAPID
SHUTDOWN DEVICE INSTALLED PER CEC
690.12
(E) RESIDENCE
(N) ARRAY AR-01(N) ARRAY AR-02(E) FENCE
MA
R
L
E
S
W
(E) GATE
FIRE SETBACKS
(18" TYP)
ROOF PATHWAYS
(3' TYP)
(E) SHEDROOF PATHWAYS
(3' TYP)
(E) DRIVEWAY
MP
SE
INV ACINV
A
B B
B B
B B
C C
C C
C C
C C
B
A A A A
AAAA
LC
RDS
PV-2.0
AC
ESS INTERIOR INSTALLATION WILL COMPLY WITH SMOKE AND HEAT
MONITORING REQUIREMENTS FOR 2025 CFC 1207.11.6
ESS INTERIOR INSTALLATION LOCATION WILL COMPLY WITH IMPACT
PROTECTION REQUIREMENTS FOR 2025 CFC 1207.11.7.3
D
EQUIPMENT INSTALLED
INSIDE THE GARAGE D EQUIPMENT
INSTALLED AT
THE EXTERIOR
Signed: 02/22/2026
ELEVATION DETAIL - SCALE = 3/8" = 1'-0"
PAGE
REV: D 2/20/2026
MARY MACALA
1301 MAR LES W, SANTA ANA,
CA, 92706
PROJECT NUMBER:
109R-301MACA PR-3004210689
SHEET
DESIGNER:
JOANNA MARIE PALMA
CUSTOMER RESIDENCE:
TEL. (714) 309-7546
APN: 198-071-46
(415) 580-6920 ex3
#ESTAMP#SSTAMP
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
ELEVATION DETAIL
PV-2.1
ESS INTERIOR INSTALLATION WILL COMPLY WITH SMOKE AND HEAT
MONITORING REQUIREMENTS FOR 2025 CFC 1207.11.6
ESS INTERIOR INSTALLATION LOCATION WILL COMPLY WITH IMPACT
PROTECTION REQUIREMENTS FOR 2025 CFC 1207.11.7.3
D
D
ENERGY STORAGE
SYSTEM
ENERGY STORAGE
SYSTEM
AC DISCONNECT
AC DISCONNECT
REMOTE DISCONNECT SWITCH
PV LOAD CENTER
SERVICE ENTRANCE
NORTH INTERIOR WALL OF THE GARAGE
NORTH EXTERIOR WALL OF THE GARAGE
Signed: 02/22/2026
NO
T
S
U
B
J
E
C
T
T
O
D
A
M
A
G
E
GARAGE FLOOR PLAN - SCALE = 1/4" = 1'-0"
PAGE
REV: D 2/20/2026
MARY MACALA
1301 MAR LES W, SANTA ANA,
CA, 92706
PROJECT NUMBER:
109R-301MACA PR-3004210689
SHEET
DESIGNER:
JOANNA MARIE PALMA
CUSTOMER RESIDENCE:
TEL. (714) 309-7546
APN: 198-071-46
(415) 580-6920 ex3
#ESTAMP#SSTAMP
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
GARAGE FLOOR PLAN
PV-2.2
ESS INTERIOR INSTALLATION WILL COMPLY WITH SMOKE AND HEAT
MONITORING REQUIREMENTS FOR 2025 CFC 1207.11.6
ESS INTERIOR INSTALLATION LOCATION WILL COMPLY WITH IMPACT
PROTECTION REQUIREMENTS FOR 2025 CFC 1207.11.7.3
D
MAIN SERVICE ENTRANCE (EXT)
PV LOAD CENTER (EXT)
REMOTE DISCONNECT SWITCH (EXT)
AC DISCONNECT (INT)
AC DISCONNECT (INT)
ENERGY STORAGE
SYSTEM (INT)
ENERGY STORAGE
SYSTEM (INT)
2'-0"
D
Signed: 02/22/2026
FACILITY
GROUND
(N) IMO PE69-3020,
DISCONNECT
SWITCH, 3P, 16A
INVERTER: TESLA
POWERWALL 3 1707000-XX-Y,
ENERGY STORAGE:
TESLA:POWERWALL 3 1707000-XX-Y
11500 WATT
INVERTER
LOAD RATED DC
DISCONNECT WITH
AFCI RAPID
SHUTDOWN
COMPLIANT,
POWER CONTROL SYSTEM
3
J-BOX
1
1
1
8 SILFAB SIL-440QD-DCA
STRING 1 WITH 8 MODULES WITH 3 MCI COUNT
MODULE LEVEL RAPID SHUTDOWN DEVICES
2
RSD
LOAD RATED DC
DISCONNECT WITH
AFCI RAPID
SHUTDOWN
COMPLIANT,
POWER CONTROL SYSTEM
INVERTER: TESLA
POWERWALL 3 1707000-XX-Y,
ENERGY STORAGE:
TESLA:POWERWALL 3 1707000-XX-Y
11500 WATT
INVERTER
3
• POINT OF INTERCONNECTION: CEC 2022 705.13, PCS
• METER NUMBER: 222013009603
• EQUIPMENT CHARACTERISTICS INCLUDED IN SPEC SHEETS
• NOTE: TOTAL PV BACKFEED = 120.0A USED FOR
INTERCONNECTION CALCULATIONS
(N) LOCKABLE
BLADE TYPE
AC DISCONNECT
SQUARE D
DU222RB
3R, 60A, 2P
120/240VAC
3
(N) LOCKABLE
BLADE TYPE
AC DISCONNECT
SQUARE D
DU222RB
3R, 60A, 2P
120/240VAC
3
(N) 125A PV
LOAD CENTER
60A BREAKER (A)
60A BREAKER (B)
4
120/240 VAC
SINGLE PHASE
SERVICE EXISTING
200A MAIN
BREAKER -CENTER FED
EXISTING 200A
MAIN PANEL
200A BUS
(E) FACILITY LOADS
M
TESLA
BACKUP
SWITCH
(N) 125A FEEDER
BREAKER
7 SILFAB SIL-440QD-DCA
STRING 1 WITH 7 MODULES WITH 3 MCI COUNT
MODULE LEVEL RAPID SHUTDOWN DEVICES
9 SILFAB SIL-440QD-DCA
STRING 1 WITH 9 MODULES WITH 3 MCI COUNT
MODULE LEVEL RAPID SHUTDOWN DEVICES
CONDUIT SCHEDULE
TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT
1 Inverter Input (2) 10 AWG (PV WIRE)N/A 6 AWG (BARE) Open Air
2 Inverter Input (6) 10 AWG
THHN/THWN-2 N/A 8 AWG THHN/THWN-2 3/4 EMT
3 Inverter Output (2) 6 AWG
THHN/THWN-2
(1) 6 AWG
THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT
4 Load Center Feeder (2) 1 AWG
THHN/THWN-2
(1) 1 AWG
THHN/THWN-2 6 AWG THHN/THWN-2 1-1/4 EMT
PAGE
REV: C 2/6/2026
MARY MACALA
1301 MAR LES W, SANTA ANA,
CA, 92706
PROJECT NUMBER:
109R-301MACA PR-3004210689
SHEET
DESIGNER:
JOANNA MARIE PALMA
CUSTOMER RESIDENCE:
TEL. (714) 309-7546
APN: 198-071-46
(415) 580-6920 ex3
#ESTAMP#SSTAMP
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
ELECTRICAL
INSTALLER MUST CHECK THE CONDITION,
INSTALLABILITY AND CODE COMPLIANCE OF
EXISTING EQUIPMENT.
POWER CONTROL SYSTEM (PCS):
• A PCS IS INSTALLED IN ACCORDANCE WITH NEC 705.13
• THE PCS SHALL LIMIT GENERATION SOURCE OUTPUT SUCH THAT CURRENT FROM ALL
SOURCES OF SUPPLY DOES NOT EXCEED THE RATING OF ANY BUSBAR OR CONDUCTOR
SUPPLIED BY THE POWER PRODUCTION SOURCES
• ANY BUSBAR OR CONDUCTOR ON THE LOAD SIDE OF THE SERVICE DISCONNECT NOT
MONITORED BY THE PCS SHALL COMPLY WITH ARTICLE 705.12.
• ACCESS TO PCS CONTROLS IS RESTRICTED TO QUALIFIED PERSONS IN ACCORDANCE
WITH 240.6(C).
• INVERTER 1: Tesla:Powerwall 3 1707000-xx-y
• ENABLE PCS; SETPOINTS:
- 160A - MAXIMUM TOTAL CURRENT ON THE CONTROLLED PANEL
- 0A - FAIL SAFE GENERATION BACKFEED CURRENT SUPPLY (120% COMPLIANT)
• INVERTER 2: Tesla:Powerwall 3 1707000-xx-y
• ENABLE PCS; SETPOINTS:
- 160A - MAXIMUM TOTAL CURRENT ON THE CONTROLLED PANEL
- 0A - FAIL SAFE GENERATION BACKFEED CURRENT SUPPLY (120% COMPLIANT)
General Notes:
• CITY REQUIRES TWO SOURCES OF GROUND - UFER, TWO GROUNDS RODS OR
COLD WATER GAS BOND
PV-4.0
C
C
FACILITY
GROUND
(N) IMO PE69-3020,
DISCONNECT
SWITCH, 3P, 16A
INVERTER: TESLA
POWERWALL 3 1707000-XX-Y,
ENERGY STORAGE:
TESLA:POWERWALL 3 1707000-XX-Y
11500 WATT
INVERTER
LOAD RATED DC
DISCONNECT WITH
AFCI RAPID
SHUTDOWN
COMPLIANT,
POWER CONTROL SYSTEM
3
J-BOX
1
1
1
8 SILFAB SIL-440QD-DCA
STRING 1 WITH 8 MODULES WITH 3 MCI COUNT
MODULE LEVEL RAPID SHUTDOWN DEVICES
2
RSD
LOAD RATED DC
DISCONNECT WITH
AFCI RAPID
SHUTDOWN
COMPLIANT,
POWER CONTROL SYSTEM
INVERTER: TESLA
POWERWALL 3 1707000-XX-Y,
ENERGY STORAGE:
TESLA:POWERWALL 3 1707000-XX-Y
11500 WATT
INVERTER
3
• POINT OF INTERCONNECTION: CEC 2022 705.13, PCS
• METER NUMBER: 222013009603
• EQUIPMENT CHARACTERISTICS INCLUDED IN SPEC SHEETS
• NOTE: TOTAL PV BACKFEED = 120.0A USED FOR
INTERCONNECTION CALCULATIONS
(N) LOCKABLE
BLADE TYPE
AC DISCONNECT
SQUARE D
DU222RB
3R, 60A, 2P
120/240VAC
3
(N) LOCKABLE
BLADE TYPE
AC DISCONNECT
SQUARE D
DU222RB
3R, 60A, 2P
120/240VAC
3
(N) 125A PV
LOAD CENTER
60A BREAKER (A)
60A BREAKER (B)
4
120/240 VAC
SINGLE PHASE
SERVICE EXISTING
200A MAIN
BREAKER -CENTER FED
EXISTING 200A
MAIN PANEL
200A BUS
(E) FACILITY LOADS
M
TESLA
BACKUP
SWITCH
(N) 125A FEEDER
BREAKER
7 SILFAB SIL-440QD-DCA
STRING 1 WITH 7 MODULES WITH 3 MCI COUNT
MODULE LEVEL RAPID SHUTDOWN DEVICES
9 SILFAB SIL-440QD-DCA
STRING 1 WITH 9 MODULES WITH 3 MCI COUNT
MODULE LEVEL RAPID SHUTDOWN DEVICES
CONDUIT SCHEDULE
TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT
1 Inverter Input (2) 10 AWG (PV WIRE)N/A 6 AWG (BARE) Open Air
2 Inverter Input (6) 10 AWG
THHN/THWN-2 N/A 8 AWG THHN/THWN-2 3/4 EMT
3 Inverter Output (2) 6 AWG
THHN/THWN-2
(1) 6 AWG
THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT
4 Load Center Feeder (2) 1 AWG
THHN/THWN-2
(1) 1 AWG
THHN/THWN-2 6 AWG THHN/THWN-2 1-1/4 EMT
PAGE
REV: D 2/20/2026
MARY MACALA
1301 MAR LES W, SANTA ANA,
CA, 92706
PROJECT NUMBER:
109R-301MACA PR-3004210689
SHEET
DESIGNER:
JOANNA MARIE PALMA
CUSTOMER RESIDENCE:
TEL. (714) 309-7546
APN: 198-071-46
(415) 580-6920 ex3
#ESTAMP#SSTAMP
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
ELECTRICAL
INSTALLER MUST CHECK THE CONDITION,
INSTALLABILITY AND CODE COMPLIANCE OF
EXISTING EQUIPMENT.
POWER CONTROL SYSTEM (PCS):
• A PCS IS INSTALLED IN ACCORDANCE WITH NEC 705.13
• THE PCS SHALL LIMIT GENERATION SOURCE OUTPUT SUCH THAT CURRENT FROM ALL
SOURCES OF SUPPLY DOES NOT EXCEED THE RATING OF ANY BUSBAR OR CONDUCTOR
SUPPLIED BY THE POWER PRODUCTION SOURCES
• ANY BUSBAR OR CONDUCTOR ON THE LOAD SIDE OF THE SERVICE DISCONNECT NOT
MONITORED BY THE PCS SHALL COMPLY WITH ARTICLE 705.12.
• ACCESS TO PCS CONTROLS IS RESTRICTED TO QUALIFIED PERSONS IN ACCORDANCE
WITH 240.6(C).
• INVERTER 1: Tesla:Powerwall 3 1707000-xx-y
• ENABLE PCS; SETPOINTS:
- 160A - MAXIMUM TOTAL CURRENT ON THE CONTROLLED PANEL
- 0A - FAIL SAFE GENERATION BACKFEED CURRENT SUPPLY (120% COMPLIANT)
• INVERTER 2: Tesla:Powerwall 3 1707000-xx-y
• ENABLE PCS; SETPOINTS:
- 160A - MAXIMUM TOTAL CURRENT ON THE CONTROLLED PANEL
- 0A - FAIL SAFE GENERATION BACKFEED CURRENT SUPPLY (120% COMPLIANT)
General Notes:
• CITY REQUIRES TWO SOURCES OF GROUND - UFER, TWO GROUNDS RODS OR
COLD WATER GAS BOND
PV-4.0
D
PAGE
REV: C 2/6/2026
MARY MACALA
1301 MAR LES W, SANTA ANA,
CA, 92706
PROJECT NUMBER:
109R-301MACA PR-3004210689
SHEET
DESIGNER:
JOANNA MARIE PALMA
CUSTOMER RESIDENCE:
TEL. (714) 309-7546
APN: 198-071-46
(415) 580-6920 ex3
#ESTAMP#SSTAMP
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
SIGNAGE 2
CAUTION:MULTIPLE SOURCES OF POWER
PER CODE(S): CEC 2022: 705.10, 710.10
1301 MAR LES W, SANTA ANA, CA, 92706
SOLAR PANELS ON ROOF
REMOTE DISCONNECT SWITCH
AC DISCONNECT
INVERTER & ENERGY STORAGE (INT)
PV LOAD CENTER
SERVICE ENTRANCE AND PV
BREAKER DISCONNECT
PV-5.1
C
PAGE
REV: D 2/20/2026
MARY MACALA
1301 MAR LES W, SANTA ANA,
CA, 92706
PROJECT NUMBER:
109R-301MACA PR-3004210689
SHEET
DESIGNER:
JOANNA MARIE PALMA
CUSTOMER RESIDENCE:
TEL. (714) 309-7546
APN: 198-071-46
(415) 580-6920 ex3
#ESTAMP#SSTAMP
2500 WHITE RD. SUITE A, IRVINE CA 92614
PHONE 805.540.7603
FAX 949.215.7778
CA CL #750184
GILBERT CORREIA, C10, C46
SIGNAGE 2
CAUTION:MULTIPLE SOURCES OF POWER
PER CODE(S): CEC 2022: 705.10, 710.10
1301 MAR LES W, SANTA ANA, CA, 92706
SOLAR PANELS ON ROOF
REMOTE DISCONNECT SWITCH (EXT)
AC DISCONNECT (INT)
INVERTER & ENERGY
STORAGE (INT)
PV LOAD CENTER (EXT)
SERVICE ENTRANCE AND PV
BREAKER DISCONNECT (EXT)
PV-5.1
D