Loading...
HomeMy WebLinkAbout1301 N Mar-Les Dr West Dr - REV 1 - PlanPL PL PL PL PL PL PL PL PL PL PL PLPLPLPLPL SITE PLAN - SCALE = 1/16" = 1'-0" PAGE REV: C 2/6/2026 MARY MACALA 1301 MAR LES W, SANTA ANA, CA, 92706 PROJECT NUMBER: 109R-301MACA PR-3004210689 SHEET DESIGNER: JOANNA MARIE PALMA CUSTOMER RESIDENCE: TEL. (714) 309-7546 APN: 198-071-46 (415) 580-6920 ex3 #ESTAMP#SSTAMP 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 SITE PLAN MAIN PANEL SERVICE ENTRANCESE MP SUB-PANELSP LEGEND SCALE: NTS NOTE: NOT ALL ITEMS IN LEGEND WILL APPEAR IN SITE PLAN ENERGY STORAGE SYSTEM (ESS) GP GENERATION PANEL INVERTER(S) AC DISCONNECT(S) DC DISCONNECT(S) INTERIOR EQUIPMENT SHOWN AS DASHEDINV AC DC METER ADAPTERMA BATTERY BP BACKUP LOADS PANEL MD MICROGRID INTERCONNECT DEVICE PV LOAD CENTERLC METER ADAPTER CONTROLLER EXTERNAL RAPID SHUTDOWN SWITCHRSD APB FRANKLIN APBOX CB IQ COMBINER BOX MAC NOTES: ·RESIDENCE DOES NOT CONTAIN ACTIVE FIRE SPRINKLERS. ARRAY DETAILS: ·TOTAL ROOF SURFACE AREA: 3505 SQFT. ·TOTAL PV ARRAY AREA: 503.8 SQ FT. ·PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE AREA) * 100 = 14.4% RAIL STANDOFFS & FOOTINGS SOLAR MODULES ARRAY PITCH PV AREA (SQFT) AR-01 23° 188.92 AR-02 23° 314.8790° TRUE AZIM MAG AZIM 168°180° 78° ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS IN ACCORDANCE WITH R328.4. ESS UNITS SHALL BE SEPARATED FROM EACH OTHER BY NOT LESS THAN 3 FEET EXCEPT WHERE SMALLER SEPARATION DISTANCES ARE DOCUMENTED TO BE ADEQUATE BASED ON LARGE/SCALE FIRE TESTING. NOTE: ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE INSTALLED PER CEC 690.12 (E) RESIDENCE (N) ARRAY AR-01(N) ARRAY AR-02(E) FENCE MA R L E S W (E) GATE FIRE SETBACKS (18" TYP) ROOF PATHWAYS (3' TYP) (E) SHEDROOF PATHWAYS (3' TYP) (E) DRIVEWAY MP SE INV ACINV A B B B B B B C C C C C C C C B A A A A AAAA LC RDS PV-2.0 AC C Signed: 2/6/2026 PL PL PL PL PL PL PL PL PL PL PL PLPLPLPLPL SITE PLAN - SCALE = 1/16" = 1'-0" PAGE REV: D 2/20/2026 MARY MACALA 1301 MAR LES W, SANTA ANA, CA, 92706 PROJECT NUMBER: 109R-301MACA PR-3004210689 SHEET DESIGNER: JOANNA MARIE PALMA CUSTOMER RESIDENCE: TEL. (714) 309-7546 APN: 198-071-46 (415) 580-6920 ex3 #ESTAMP#SSTAMP 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 SITE PLAN MAIN PANEL SERVICE ENTRANCESE MP SUB-PANELSP LEGEND SCALE: NTS NOTE: NOT ALL ITEMS IN LEGEND WILL APPEAR IN SITE PLAN ENERGY STORAGE SYSTEM (ESS) GP GENERATION PANEL INVERTER(S) AC DISCONNECT(S) DC DISCONNECT(S) INTERIOR EQUIPMENT SHOWN AS DASHEDINV AC DC METER ADAPTERMA BATTERY BP BACKUP LOADS PANEL MD MICROGRID INTERCONNECT DEVICE PV LOAD CENTERLC METER ADAPTER CONTROLLER EXTERNAL RAPID SHUTDOWN SWITCHRSD APB FRANKLIN APBOX CB IQ COMBINER BOX MAC NOTES: ·RESIDENCE DOES NOT CONTAIN ACTIVE FIRE SPRINKLERS. ARRAY DETAILS: ·TOTAL ROOF SURFACE AREA: 3505 SQFT. ·TOTAL PV ARRAY AREA: 503.8 SQ FT. ·PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE AREA) * 100 = 14.4% RAIL STANDOFFS & FOOTINGS SOLAR MODULES ARRAY PITCH PV AREA (SQFT) AR-01 23° 188.92 AR-02 23° 314.8790° TRUE AZIM MAG AZIM 168°180° 78° ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS IN ACCORDANCE WITH R328.4. ESS UNITS SHALL BE SEPARATED FROM EACH OTHER BY NOT LESS THAN 3 FEET EXCEPT WHERE SMALLER SEPARATION DISTANCES ARE DOCUMENTED TO BE ADEQUATE BASED ON LARGE/SCALE FIRE TESTING. NOTE: ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE INSTALLED PER CEC 690.12 (E) RESIDENCE (N) ARRAY AR-01(N) ARRAY AR-02(E) FENCE MA R L E S W (E) GATE FIRE SETBACKS (18" TYP) ROOF PATHWAYS (3' TYP) (E) SHEDROOF PATHWAYS (3' TYP) (E) DRIVEWAY MP SE INV ACINV A B B B B B B C C C C C C C C B A A A A AAAA LC RDS PV-2.0 AC ESS INTERIOR INSTALLATION WILL COMPLY WITH SMOKE AND HEAT MONITORING REQUIREMENTS FOR 2025 CFC 1207.11.6 ESS INTERIOR INSTALLATION LOCATION WILL COMPLY WITH IMPACT PROTECTION REQUIREMENTS FOR 2025 CFC 1207.11.7.3 D EQUIPMENT INSTALLED INSIDE THE GARAGE D EQUIPMENT INSTALLED AT THE EXTERIOR Signed: 02/22/2026 ELEVATION DETAIL - SCALE = 3/8" = 1'-0" PAGE REV: D 2/20/2026 MARY MACALA 1301 MAR LES W, SANTA ANA, CA, 92706 PROJECT NUMBER: 109R-301MACA PR-3004210689 SHEET DESIGNER: JOANNA MARIE PALMA CUSTOMER RESIDENCE: TEL. (714) 309-7546 APN: 198-071-46 (415) 580-6920 ex3 #ESTAMP#SSTAMP 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 ELEVATION DETAIL PV-2.1 ESS INTERIOR INSTALLATION WILL COMPLY WITH SMOKE AND HEAT MONITORING REQUIREMENTS FOR 2025 CFC 1207.11.6 ESS INTERIOR INSTALLATION LOCATION WILL COMPLY WITH IMPACT PROTECTION REQUIREMENTS FOR 2025 CFC 1207.11.7.3 D D ENERGY STORAGE SYSTEM ENERGY STORAGE SYSTEM AC DISCONNECT AC DISCONNECT REMOTE DISCONNECT SWITCH PV LOAD CENTER SERVICE ENTRANCE NORTH INTERIOR WALL OF THE GARAGE NORTH EXTERIOR WALL OF THE GARAGE Signed: 02/22/2026 NO T S U B J E C T T O D A M A G E GARAGE FLOOR PLAN - SCALE = 1/4" = 1'-0" PAGE REV: D 2/20/2026 MARY MACALA 1301 MAR LES W, SANTA ANA, CA, 92706 PROJECT NUMBER: 109R-301MACA PR-3004210689 SHEET DESIGNER: JOANNA MARIE PALMA CUSTOMER RESIDENCE: TEL. (714) 309-7546 APN: 198-071-46 (415) 580-6920 ex3 #ESTAMP#SSTAMP 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 GARAGE FLOOR PLAN PV-2.2 ESS INTERIOR INSTALLATION WILL COMPLY WITH SMOKE AND HEAT MONITORING REQUIREMENTS FOR 2025 CFC 1207.11.6 ESS INTERIOR INSTALLATION LOCATION WILL COMPLY WITH IMPACT PROTECTION REQUIREMENTS FOR 2025 CFC 1207.11.7.3 D MAIN SERVICE ENTRANCE (EXT) PV LOAD CENTER (EXT) REMOTE DISCONNECT SWITCH (EXT) AC DISCONNECT (INT) AC DISCONNECT (INT) ENERGY STORAGE SYSTEM (INT) ENERGY STORAGE SYSTEM (INT) 2'-0" D Signed: 02/22/2026 FACILITY GROUND (N) IMO PE69-3020, DISCONNECT SWITCH, 3P, 16A INVERTER: TESLA POWERWALL 3 1707000-XX-Y, ENERGY STORAGE: TESLA:POWERWALL 3 1707000-XX-Y 11500 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT, POWER CONTROL SYSTEM 3 J-BOX 1 1 1 8 SILFAB SIL-440QD-DCA STRING 1 WITH 8 MODULES WITH 3 MCI COUNT MODULE LEVEL RAPID SHUTDOWN DEVICES 2 RSD LOAD RATED DC DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT, POWER CONTROL SYSTEM INVERTER: TESLA POWERWALL 3 1707000-XX-Y, ENERGY STORAGE: TESLA:POWERWALL 3 1707000-XX-Y 11500 WATT INVERTER 3 • POINT OF INTERCONNECTION: CEC 2022 705.13, PCS • METER NUMBER: 222013009603 • EQUIPMENT CHARACTERISTICS INCLUDED IN SPEC SHEETS • NOTE: TOTAL PV BACKFEED = 120.0A USED FOR INTERCONNECTION CALCULATIONS (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A, 2P 120/240VAC 3 (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A, 2P 120/240VAC 3 (N) 125A PV LOAD CENTER 60A BREAKER (A) 60A BREAKER (B) 4 120/240 VAC SINGLE PHASE SERVICE EXISTING 200A MAIN BREAKER -CENTER FED EXISTING 200A MAIN PANEL 200A BUS (E) FACILITY LOADS M TESLA BACKUP SWITCH (N) 125A FEEDER BREAKER 7 SILFAB SIL-440QD-DCA STRING 1 WITH 7 MODULES WITH 3 MCI COUNT MODULE LEVEL RAPID SHUTDOWN DEVICES 9 SILFAB SIL-440QD-DCA STRING 1 WITH 9 MODULES WITH 3 MCI COUNT MODULE LEVEL RAPID SHUTDOWN DEVICES CONDUIT SCHEDULE TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT 1 Inverter Input (2) 10 AWG (PV WIRE)N/A 6 AWG (BARE) Open Air 2 Inverter Input (6) 10 AWG THHN/THWN-2 N/A 8 AWG THHN/THWN-2 3/4 EMT 3 Inverter Output (2) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT 4 Load Center Feeder (2) 1 AWG THHN/THWN-2 (1) 1 AWG THHN/THWN-2 6 AWG THHN/THWN-2 1-1/4 EMT PAGE REV: C 2/6/2026 MARY MACALA 1301 MAR LES W, SANTA ANA, CA, 92706 PROJECT NUMBER: 109R-301MACA PR-3004210689 SHEET DESIGNER: JOANNA MARIE PALMA CUSTOMER RESIDENCE: TEL. (714) 309-7546 APN: 198-071-46 (415) 580-6920 ex3 #ESTAMP#SSTAMP 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 ELECTRICAL INSTALLER MUST CHECK THE CONDITION, INSTALLABILITY AND CODE COMPLIANCE OF EXISTING EQUIPMENT. POWER CONTROL SYSTEM (PCS): • A PCS IS INSTALLED IN ACCORDANCE WITH NEC 705.13 • THE PCS SHALL LIMIT GENERATION SOURCE OUTPUT SUCH THAT CURRENT FROM ALL SOURCES OF SUPPLY DOES NOT EXCEED THE RATING OF ANY BUSBAR OR CONDUCTOR SUPPLIED BY THE POWER PRODUCTION SOURCES • ANY BUSBAR OR CONDUCTOR ON THE LOAD SIDE OF THE SERVICE DISCONNECT NOT MONITORED BY THE PCS SHALL COMPLY WITH ARTICLE 705.12. • ACCESS TO PCS CONTROLS IS RESTRICTED TO QUALIFIED PERSONS IN ACCORDANCE WITH 240.6(C). • INVERTER 1: Tesla:Powerwall 3 1707000-xx-y • ENABLE PCS; SETPOINTS: - 160A - MAXIMUM TOTAL CURRENT ON THE CONTROLLED PANEL - 0A - FAIL SAFE GENERATION BACKFEED CURRENT SUPPLY (120% COMPLIANT) • INVERTER 2: Tesla:Powerwall 3 1707000-xx-y • ENABLE PCS; SETPOINTS: - 160A - MAXIMUM TOTAL CURRENT ON THE CONTROLLED PANEL - 0A - FAIL SAFE GENERATION BACKFEED CURRENT SUPPLY (120% COMPLIANT) General Notes: • CITY REQUIRES TWO SOURCES OF GROUND - UFER, TWO GROUNDS RODS OR COLD WATER GAS BOND PV-4.0 C C FACILITY GROUND (N) IMO PE69-3020, DISCONNECT SWITCH, 3P, 16A INVERTER: TESLA POWERWALL 3 1707000-XX-Y, ENERGY STORAGE: TESLA:POWERWALL 3 1707000-XX-Y 11500 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT, POWER CONTROL SYSTEM 3 J-BOX 1 1 1 8 SILFAB SIL-440QD-DCA STRING 1 WITH 8 MODULES WITH 3 MCI COUNT MODULE LEVEL RAPID SHUTDOWN DEVICES 2 RSD LOAD RATED DC DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT, POWER CONTROL SYSTEM INVERTER: TESLA POWERWALL 3 1707000-XX-Y, ENERGY STORAGE: TESLA:POWERWALL 3 1707000-XX-Y 11500 WATT INVERTER 3 • POINT OF INTERCONNECTION: CEC 2022 705.13, PCS • METER NUMBER: 222013009603 • EQUIPMENT CHARACTERISTICS INCLUDED IN SPEC SHEETS • NOTE: TOTAL PV BACKFEED = 120.0A USED FOR INTERCONNECTION CALCULATIONS (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A, 2P 120/240VAC 3 (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A, 2P 120/240VAC 3 (N) 125A PV LOAD CENTER 60A BREAKER (A) 60A BREAKER (B) 4 120/240 VAC SINGLE PHASE SERVICE EXISTING 200A MAIN BREAKER -CENTER FED EXISTING 200A MAIN PANEL 200A BUS (E) FACILITY LOADS M TESLA BACKUP SWITCH (N) 125A FEEDER BREAKER 7 SILFAB SIL-440QD-DCA STRING 1 WITH 7 MODULES WITH 3 MCI COUNT MODULE LEVEL RAPID SHUTDOWN DEVICES 9 SILFAB SIL-440QD-DCA STRING 1 WITH 9 MODULES WITH 3 MCI COUNT MODULE LEVEL RAPID SHUTDOWN DEVICES CONDUIT SCHEDULE TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT 1 Inverter Input (2) 10 AWG (PV WIRE)N/A 6 AWG (BARE) Open Air 2 Inverter Input (6) 10 AWG THHN/THWN-2 N/A 8 AWG THHN/THWN-2 3/4 EMT 3 Inverter Output (2) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT 4 Load Center Feeder (2) 1 AWG THHN/THWN-2 (1) 1 AWG THHN/THWN-2 6 AWG THHN/THWN-2 1-1/4 EMT PAGE REV: D 2/20/2026 MARY MACALA 1301 MAR LES W, SANTA ANA, CA, 92706 PROJECT NUMBER: 109R-301MACA PR-3004210689 SHEET DESIGNER: JOANNA MARIE PALMA CUSTOMER RESIDENCE: TEL. (714) 309-7546 APN: 198-071-46 (415) 580-6920 ex3 #ESTAMP#SSTAMP 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 ELECTRICAL INSTALLER MUST CHECK THE CONDITION, INSTALLABILITY AND CODE COMPLIANCE OF EXISTING EQUIPMENT. POWER CONTROL SYSTEM (PCS): • A PCS IS INSTALLED IN ACCORDANCE WITH NEC 705.13 • THE PCS SHALL LIMIT GENERATION SOURCE OUTPUT SUCH THAT CURRENT FROM ALL SOURCES OF SUPPLY DOES NOT EXCEED THE RATING OF ANY BUSBAR OR CONDUCTOR SUPPLIED BY THE POWER PRODUCTION SOURCES • ANY BUSBAR OR CONDUCTOR ON THE LOAD SIDE OF THE SERVICE DISCONNECT NOT MONITORED BY THE PCS SHALL COMPLY WITH ARTICLE 705.12. • ACCESS TO PCS CONTROLS IS RESTRICTED TO QUALIFIED PERSONS IN ACCORDANCE WITH 240.6(C). • INVERTER 1: Tesla:Powerwall 3 1707000-xx-y • ENABLE PCS; SETPOINTS: - 160A - MAXIMUM TOTAL CURRENT ON THE CONTROLLED PANEL - 0A - FAIL SAFE GENERATION BACKFEED CURRENT SUPPLY (120% COMPLIANT) • INVERTER 2: Tesla:Powerwall 3 1707000-xx-y • ENABLE PCS; SETPOINTS: - 160A - MAXIMUM TOTAL CURRENT ON THE CONTROLLED PANEL - 0A - FAIL SAFE GENERATION BACKFEED CURRENT SUPPLY (120% COMPLIANT) General Notes: • CITY REQUIRES TWO SOURCES OF GROUND - UFER, TWO GROUNDS RODS OR COLD WATER GAS BOND PV-4.0 D PAGE REV: C 2/6/2026 MARY MACALA 1301 MAR LES W, SANTA ANA, CA, 92706 PROJECT NUMBER: 109R-301MACA PR-3004210689 SHEET DESIGNER: JOANNA MARIE PALMA CUSTOMER RESIDENCE: TEL. (714) 309-7546 APN: 198-071-46 (415) 580-6920 ex3 #ESTAMP#SSTAMP 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 SIGNAGE 2 CAUTION:MULTIPLE SOURCES OF POWER PER CODE(S): CEC 2022: 705.10, 710.10 1301 MAR LES W, SANTA ANA, CA, 92706 SOLAR PANELS ON ROOF REMOTE DISCONNECT SWITCH AC DISCONNECT INVERTER & ENERGY STORAGE (INT) PV LOAD CENTER SERVICE ENTRANCE AND PV BREAKER DISCONNECT PV-5.1 C PAGE REV: D 2/20/2026 MARY MACALA 1301 MAR LES W, SANTA ANA, CA, 92706 PROJECT NUMBER: 109R-301MACA PR-3004210689 SHEET DESIGNER: JOANNA MARIE PALMA CUSTOMER RESIDENCE: TEL. (714) 309-7546 APN: 198-071-46 (415) 580-6920 ex3 #ESTAMP#SSTAMP 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 SIGNAGE 2 CAUTION:MULTIPLE SOURCES OF POWER PER CODE(S): CEC 2022: 705.10, 710.10 1301 MAR LES W, SANTA ANA, CA, 92706 SOLAR PANELS ON ROOF REMOTE DISCONNECT SWITCH (EXT) AC DISCONNECT (INT) INVERTER & ENERGY STORAGE (INT) PV LOAD CENTER (EXT) SERVICE ENTRANCE AND PV BREAKER DISCONNECT (EXT) PV-5.1 D