HomeMy WebLinkAboutHOLD - 1511 & 1513 S Birch St - PlanPROPERTY DATA
ADDRESS:1511 S. BIRCH ST.
SANTA ANA, CA 92707
APN:013-182-06
LEGAL DESCRIPTION:TRACT NO 531
LOTS 49/50 BLK C
ZONE:R1 (SINGLE FAMILY RESIDENTIAL)
LOT SIZE:6,000 SF
(E) BUILDING AREA: (E) 1-STORY SFR 1,121 SF
(E) FRONT PORCH 70 SF
(E) REAR PATIO COVER 148 SF
(E) GARAGE 373 SF
(E) PERGOLA -
(N) GARAGE ADDITION
(TO BE LEGALIZED) 249 SF
(N) REAR ATTACHED PATIO 160 SF
TOTAL AREA
LOT COVERAGE: 2,121/ 6,000 SF = .35 = 35%
DWELLING UNITS:2OWNER INFORMATION
OWNER: SILVIA TORRES
ADDRESS: 1511 S. BIRCH ST.
SANTA ANA, CA 92707
PHONE:(714) 925-3782
SCOPE OF WORK
• CONVERT EXISTING DETACHED GARAGE AND
REAR ADDITION INTO AN ADU
• (TOTAL ADU SIZE 622 SF)
• LEGALIZE A (249 SF) ADDITION ATTACHED TO
GARAGE AND CONVERT TO ADU
• LEGALIZE ATTACHED PATIO COVER (172 SF).
• DEMOLISH EXISTING PERGOLA
CONSTRUCTION NOTES
1. CONTRACTOR TO PROVIDE EXTERIOR GLAZED OPENINGS FOR
NATURAL LIGHT EQUAL TO 1/10TH OF THE FLOOR AREA (10 SQ. FT
MIN.) FOR FAMILY ROOM.
2. ALL ADDITIONAL ROOMS SHALL HAVE A MIN. OF 7’-6”CEILING
HEIGHT (PER 2022 CRC)
3. CONTRACTOR TO PROVIDE SMOKE DETECTOR IN EACH SLEEPING
ROOM AND AT A POINT CENTRALLY LOCATED IN THE CORRIDOR OF
AREA GIVING ACCESS TO EACH SEPARATE SLEEPING AREA AND IN
EACH STORY OR BASEMENT AND IF SLEEPING ROOMS ARE AT AN
UPPER LEVEL, PROVIDE A DETECTOR AT THE CEILING OF THE
UPPER LEVEL IN CLOSE PROXIMITY TO THE STAIRWAY IF
APPLICABLE (PER 2022 CRC).
4. MASTER BEDROOM SHALL HAVE AT LEAST ONE OPERABLE
WINDOW OR DOOR APPROVED FROM EMERGENCY ESCAPE OR
RESCUE WHICH SHALL OPEN DIRECTLY ONTO A PUBLIC STREET,
PUBLIC ALLEY, YARD OR EXIT COURT. THE OPENING SHALL
CONFORM TO THE FOLLOWING:
a. MIN AREA = 5.7 SQ FT.
b. 20”MIN WIDTH
c. 24”MIN HEIGHT
d. FINISH SILL AT 44”MAX ABOVE THE FLOOR
e. SECURITY BARS/GRILLES MAY BE INSTALLED IF EQUIPPED WITH
APPROVED RELEASED DEVICES OPERABLE WITHOUT THE USE OF A
KEY OF SPECIAL KNOWLEDGE AND PROVIDED THE BUILDING
EQUIPPED WITH SMOKE DETECTOR (PER 2022 CRC).
5. PER 2022 CRC:
a. NOTCHING OF STUDS IN BEARING PARTITIONS SHALL NOT
EXCEED 25% OF THE WIDTH.
b. NOTCHING OF STUDS IN NONBEARING PARTITIONS SHALL NOT
EXCEED 40% OF THE WIDTH.
c. BORED HOLES IN STUD IN BEARING PARTITIONS SHALL NOT
EXCEED 40% OF THE WIDTH.
d. BORED HOLES IN THE STUDS IN NONBEARING PARTITIONS SHALL
NOT EXCEED 60% OF THE WIDTH (UNLESS THE BORED STUDS ARE
DOUBLE AND NO MORE THAN TWO SUCH SUCCESSIVE DOUBLE
STUDS ARE SO BORED)
e. BORE HOLES MAY NOT BE LOCATED NEARER THAN 5/8”TO THE
EDGE OF THE STUD AND MAY NOT BE LOCATED IN THE SAME
DIRECTION OF THE STUD AS A CUT OR NOTCH.
6. PURLINS SHALL NOT BE SMALLER THAN THE SUPPORTED
RAFTERS. MAX SPAN OF 2X4 AND 2X6 PURLINS IS 4’-0”AND 6’-0”
RESPECTIVELY. STUDS SHALL BE 2X4 MIN. 8-‘0”LONG MAX AND NOT
LESS THAN 45 DEGREES FROM THE HORIZONTAL (PER 2022 CRC).
7. FOR ATTICS WITH A VERTICAL CLEAR HEIGHT OF 30”OR MORE,
PROVIDE A READILY ACCESSIBLE ATTIC ACCESS OPENING IN THE
CEILING. OPENING SHALL BE 22X30 MIN. AND HAVE 30”MIN HEAD
ROOM (PER 2022 CRC).
8. CONTRACTOR TO PROVIDE VENTILATION FOR ATTIC SPACES AND
ENCLOSE RAFTER SPACES. VENTILATION OPENINGS SHALL BE NOT
LESS THAN 1/150 OF THE AREA VENTILATED. OPENINGS MAY BE
REDUCED TO 1/300 IF 50% OF THE OPENING ARE IN THE UPPER
PORTION OF THE SPACE AND AT LEAST 3’-0”ABOVE THE EAVES.
CORROSION RESISTANT MESH WITH ¼”MAX OPENING IS REQUIRED
(PER 2022 CRC).
9. IN ACCORDANCE WITH THE 2022 CALIFORNIA GREEN BUILDING
STANDARDS CODE AND CALIFORNIA CIVIL CODE SECTION 1101.1;
ALL EXISTING RESIDENTIAL BUILDINGS UNDERGOING PERMITTED
ALTERATION, ADDITIONS, OR IMPROVEMENTS SHALL REPLACE ALL
NON-COMPLIANT PLUMBING FIXTURES WITH WATER CONSERVING
PLUMBING FIXTURES PRIOR TO ANY PERMIT FINAL APPROVALS OR
THE ISSUANCE OF CERTIFICATE OF OCCUPANCY UNLESS NOTED
OTHERWISE.
10. WHERE THE PERMIT IS REQUIRED FOR ALTERATION, REPAIRS
OR ADDITIONS EXCEEDING $1,000 EXISTING DWELLING THAT HAVE
ATTACHED GARAGES OF FUEL-BURNING APPLIANCES SHALL BE
PROVIDE WITH CARBON MONOXIDE ALARM(S) IN ACCORDANCE
WITH CRC 315.1 EXCEPTIONS: HARD WIRING WITH BATTERY BACKUP
INTERCONNECTION IS NOT REQUIRED WITHIN EXISTING DWELLING
UNITS WHERE THERE IS NO COMMERCIAL POWER SUPPLY OR ANY
ALTERATION OR REPAIRS DOES NOT RESULT IN THE REMOVAL OF
WALL AND CEILING FINISHES OR THERE IS NO ACCESS BY MEANS OF
ATTIC; BASEMENT OR CRAWL SPACE.
11. WHERE ALTERATIONS, REPAIR OR ADDITIONS REQUIRING A
PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE
ADDED OR CREATED IN EXISTING DWELLING, SMOKE ALARMS
LISTED IN ACCORDANCE WITH UL 217 SHALL BE INSTALLED A
REQUIRED FOR NEW CONSTRUCTION. R314.3.1 EXCEPTION: HARD
WIRING WITH BATTERY BACKUP AND INTERCONNECTIONS IS NOT
REQUIRED WITHIN EXISTING DWELLING UNITS WHERE THERE IS NO
COMMERCIAL POWER SUPPLY OR ANY ALTERATION OR REPAIR
DOES NOT RESULT IN THE REMOVAL OF WALL AND CEILING
FINISHES OR THERE IS NO ACCESS BY MEAN OF ATTIC; BASEMENT
OR CRAWL SPACE.
12. ALL OUTLETS INSTALLED IN DWELLING UNIT BEDROOMS, FAMILY
ROOMS, DINING ROMS, LIVING ROOMS, PARLORS, DENS, LIBRARIES,
SUN ROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS, OR
SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED
“COMBINES TYPE”ARC-FAULT CIRCUIT INTERRUPTED, INSTALLED TO
PROVIDE PROTECTION OF BRANCH CIRCUIT. 2022 CEC, 210.12(B).
13. IN ALL AREAS SPECIFIED IN CEC 210.52, ALL NEW 15 AND 20
AMPERE DWELLING UNIT RECEPTACLES SHALL BE LISTED TAMPER
RESISTANT RECEPTACLES. 2022 CEC 406.12
14. SEC 903.2.1 CRC ROOF FLASHING SHALL BE INSTALLED IN
ACCORDANCE WITH THIS CODE AT ALL WALL AND ROOF
INTERSECTIONS, WHEREVER THERE IS A CHANGE IN ROOF SLOPE
OR DIRECTION AND AROUND ALL ROOF OPENINGS AND
PENETRATIONS, ALL METAL FLASHING SHALL BE CORROSION
RESISTANT WITH THICKNESS OF NOT LESS THAN (0.019) INCHES (NO.
26 GAGE GALVANIZED SHEET METAL.
15. A RADIANT BARRIER IS REQUIRED (FOR CLIMATE ZONES 2-15).
RADIANT BARRIERS SHALL MEET SPECIFIC ELIGIBILITY AND
INSTALLATION CRITERIA TO RECEIVE ENERGY CREDIT FOR
COMPLIANCE WITH THE BUILDING ENERGY EFFICIENCY STANDARDS
FOR LOW-RISE RESIDENTIAL BUILDING. REFER TO RA4.2.1 THE
EMITTANCE OF THE RADIANT BARRIER SHALL BE LESS THAN OR
EQUAL TO 0.05 AS TESTED IN ACCORDANCE WITH ASTM C1371 OR
ASTM E408. FOR PRESCRIPTIVE COMPLIANCE, THE ATTIC SHALL BE
VENTILATED TO PROVIDE A MINIMUM FREE VENTILATION AREA OF
NOT LESS THAN ONE SQ. FT. OF VENT AREA FOR EACH 300 SQ. FT.
OF ATTIC FLOOR ARE WITH NO LESS THAN 30% UPPER VENT. RIDGE
VENTS OR GABLE END VENTS ARE RECOMMENDED TO ACHIEVE THE
BEST PERFORMANCE. THE MATERIAL SHOULD BE CUT TO ALLOW
FOR FULL AIRFLOW TO THE VENTING.
SITE PLAN LEGEND
PROPERTY LINE (E) STRUCTURE
(E) STRUCTURE TO BE MODIFIEDCMU WALL W/
FENCE ABOVE
6'-0" DECORATIVE
IRON FENCE
CMU BLOCK WALL
VINYL FENCE
(N) ADDITION
SHEET FLOW @ MIN. 2% SLOPE
SHEET FLOW NOTE:
IMPERVIOUS IMPERVIOUS SURFACE SHALL BE SLOPED AWAY FROM THE BUILDING AT
2% MINIMUM SLOPE FOR A MINIMUM DISTANCE OF 10 FEET; LOT SHALL BE GRADED TO
DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS; GRADE SHALL FALL 6”
MINIMUM WITHIN THE FIRST 10 FT. –PER SECTION R401.3
CONSULTANTS
STRUCTURAL ENGINEERING:
FRANCISCO GARCIA, P.E.
FJ ENGINEERING+DESIGN
600 W. MAIN ST. SUITE 207
ALHAMBRA, CA 91801
(626)548-3874
MECHANICAL ENGINEERING:
LAWRENCE GORDON
LRG DESIGNS
P.O. BOX 47478
LOS ANGELES, CA 90047
(323)955-9827
DEFFERED SUBMITTALS
• N/A
UNDERGROUND SLEEVING
FOR GAS LINE
1. CONDUIT SHALL BE SOLID AND NON-METALIC FOR 1-INCH THROUGH
4-INCH SIZE.
2. CONDUIT MUST BE A CONTINUOUS LENGTH, AND BENDS MUST BE
GRADUAL.
3. IF INSTALLED IN SAME TRENCH AS ELECTRICAL LINES, CONDUITS
MUST HAVE A MINIMUM SEPARATION EITHER VERTICALLY OR
HORIZONTALLY OF 12 INCHES.
4. MINIMUM DEPTH SHALL BE 24 INCHES FROM FINAL GRADE.
5. CONDUIT SIZE SHALL BE AS FOLLOWS:
6. THE ENDS OF THE CONDUIT SHALL BE SEALED TO PREVENT ENTRY
OF SOIL OR WATER.
7. CONDUIT SHALL BE TAG "GAS" UNDERGROUND.
GAS SERVICE SIZE (INCHES)
5/8"
1-1/8"
1-1/4"
2"
CONDUIT SIZE (INCHES)
1" SOLID / NON-METALLIC
2" SOLID / NON-METALLIC
3" SOLID / NON-METALLIC
4" SOLID / NON-METALLIC
UNDERGROUND GAS-LINE LEGEND
(E) CONC. DRIVEWAY
(E) SINGLE-
FAMILY
RESIDENCE
(1121 SF)
(E) FRONT
PORCH
(E) CANOPY TO
BE REMOVED
AND REBUILT.
(E) LANDSCAPE
(E) POOL
NOT A PART
G
(E) GAS
METER
(E) MAIN
ELEC.
PANEL
BIRCH ST.
(E) 3/4" WATER
METER (V.I.F.)
w (E) PARKWAY
(E) SIDEWALK
50'-0"
12
0
'
-
0
"
6'
-
0
"
4'
-
0
"
20'-0"
(E) REAR
PATIO COVER
(N) ADDITION
(TO BE LEGALIZED)
(249 SF)
(E) PERGOLA
TO BE REMOVED
(E) CONC.
PAVING
(E) ELECT.
SUBPANEL
3'-2"
TO BE
PARTIALLY
DEMO.
5'
-
0
"
18
'
-
8
"
4'-0"
ADDRESS: 1511
(E) GARAGE
TO BE CONVERTED
TO AN ADU
(373 SF)
TOTAL ADU SIZE
622 SF
(E) FENCE
(E) GATE W/ ALARM
DROWNING
PREVENTION ITEMS:
(E) FENCE & ALARM
1'-0"
(E) CONC. DRIVEWAY
(E) POOL
G
BIRCH ST.
(E) 3/4" WATER
METER (V.I.F.)
w (E) PARKWAY
(E) SIDEWALK
50'-0"
12
0
'
-
0
"
(E) CONC.
PAVING
6'
-
0
"
4'
-
0
"
20'-0"
6'
-
0
"
(E) SINGLE-FAMILY
RESIDENCE
(1121 SF)
(E) FRONT
PORCH
NOT A PART
(E) MAIN
ELEC.
PANEL
(E) REAR PATIO COVER
(N) PATIO COVER
(N) ADDITION
(TO BE LEGALIZED)
(249 SF)
(E) GARAGE
TO BE CONVERTED
TO AN ADU
(373 SF)
(E) ELECT.
SUBPANEL
(E) LANDSCAPE
(E) GAS
METER
(E) FENCECLR.
5'-0"
13'-9"
11
'
-
8
"
@
W
A
L
L
(E
)
5
'
-
0
"
@
R
O
O
F
(E
)
3
'
-
9
"
@ ROOF/WALL
4'-0"
18
'
-
7
"
13'-4 1/2"
SL
O
P
E
1511 S. BIRCH STREET
SANTA ANA, CA 90727
1513 S. BIRCH STREET
SANTA ANA, CA 90727
(E) GATE W/ ALARM
DROWNING
PREVENTION ITEMS:
(E) FENCE & ALARM
TOTAL ADU SIZE
622 SF
1'-0"
ISSUED
DATE:
REVISIONS
DRAWINGS, SPECIFICATIONS AND OTHER VISUAL AIDS, AS
INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE
DRAFTER/DESIGNER WHETHER THE PROJECT FOR
WHICH THEY ARE MADE BE EXECUTED OR NOT, AND
THEY ARE NOT TO BE USED FOR ANY OTHER SITE THAN
THE ONE FOR WHICH THEY ARE PREPARED, EXCEPT BY
AGREEMENT IN WRITING.
NO
.
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
DRAFTER/DESIGNER:
LUIS N OROZCO
562.661.9281
LUIS.OROZCO.A@LIVE.COM
DATE:
11/19/2024
G101
COVER SHEET
PR
O
P
E
R
T
Y
O
W
N
E
R
:
S
I
L
V
I
A
T
O
R
R
E
S
15
1
1
S
.
B
I
R
C
H
S
T
.
SA
N
T
A
A
N
A
,
C
A
9
0
7
2
7
GA
R
A
G
E
C
O
N
V
E
R
S
I
O
N
T
O
A
N
AC
C
E
S
S
O
R
Y
D
W
E
L
L
I
N
G
U
N
I
T
09/10/2024
SHEET INDEXADU -GARAGE CONVERSION
1511 S. BIRCH ST., SANTA ANA, CA 90727 -SFR
APPLICABLE CODES
THIS PROJECT SHALL COMPLY WITH THE FOLLOWING:
2022 CALIFORNIA BUILDING CODE -TITLE 24, PART 2
2022 CALIFORNIA RESIDENTIAL CODE -TITLE 24, PART 2.5
2022 CALIFORNIA MECHANICAL CODE -TITLE 24, PART 4
2022 CALIFORNIA PLUMBING CODE -TITLE 24, PART 5
2022 CALIFORNIA ELECTRICAL CODE -TITLE 24, PART 3
2022 CALIFORNIA ENERGY CODE -TITLE 24, PART 6
2022 CALIFORNIA GREEN BUILDING STANDARDS CODE -
TITLE 24, PART 11
2022 ORANGE COUNTY FIRE CODE
CITY OF SANTA ANA REGULATIONS AND ORDINANCES
BUILDING DATA
CONSTRUCTION TYPE: V-B -RESIDENTIAL PRESCRIPTIVE WOOD
NUMBER OF STORIES/ HEIGHT: ONE STORY
FIRE SPRINKLER SYSTEM: NONE EXISTING/ NONE REQUIRED
BASEMENT: NO
TYPE OF ROOF: ASPHALT COMPOSITION SHINGLES
OCCUPANCY LOADS:
ADU: R-3 OCCUPANCY (200 OCCUPANT LOAD) = 373/200= 2 OCCUPANTS
CAL. GREEN BLDG.
STANDARDS
1. ALL FINISH MATERIALS, SUCH AS ADHESIVES, SEALANTS,
CAULKS, PAINTS, AEROSOLS PAINTS, COATING, CARPET
SYSTEMS, RESILIENT FLOORING SYSTEMS AND COMPOSITE
WOOD PRODUCTS SHALL CONFORM TO THE VOC. AND
FORMALDEHYDE LIMITS SET FORTH IN SECTION 4.504.2. 4.504.3,
4.504.4, 4.504.5 AND TABLE 4.504.1, 4.504.2, 4.504.3 AND 4.504.5
(4.405.2 CGBSC)
2. BATHROOM EXHAUST FANS, A ROOM WHICH CONTAINS A
BATHTUB, SHOWER OR TUB/SHOWER COMBINATION, SHALL
COMPLY WITH THE FOLLOWING. PROVIDE NOTES ON THE PLANS.
(4.506.1 CGBSC)
A) FANS SHALL BE ENERGY STAR COMPLIANT AND BE
DUCTED TO TERMINATE OUTSIDE THE BUILDING.
B) UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE
HOUSE VENTILATION SYSTEM, THE FAN MUST BE
CONTROLLED BY A HUMIDISTAT WHICH SHALL BE
READILY ACCESSIBLE. HUMIDISTAT CONTROLS SHALL BE
CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE
HUMIDITY RANGE OF 50 TO 80%. A HUMIDITY CONTROL
MAY BE A SEPARATE COMPONENT TO AN EXHAUST FAN
AND IS NOT REQUIRED TO BE INTEGRAL (I.E. BUILT-IN).
ASSESSOR'S MAP VICINITY MAP
NORTH
01 - GENERAL
G101 COVER SHEET
G102 GENERAL NOTES
G103 GENERAL NOTES
G104 CALGREEN RESIDENTIAL MANDATORY MEASURES
G105 CALGREEN RESIDENTIAL MANDATORY MEASURES
02 - ARCHITECTURAL
A101 FLOOR PLANS
A102 REFLECTED CEILING PLAN & ROOF PLAN
A201 EXTERIOR ELEVATIONS
A301 ENLARGED FLOOR PLANS & INTERIOR ELEVATIONS
A401 WALL SECTIONS
A501 DETAILS - CONSTRUCTION
A502 DETAILS - CONSTRUCTION
A503 DETAILS - TYP. CONSTRUCTION
A601 SCHEDULES
STRUCTURAL
S-0 STRUCTURAL NOTES & SCHEDULES
S-1 FOUNDATION PLA
S-2 CEILING AND ROOF FRAMING PLANS
SD-1 STRUCTURAL DETAILS
T24 / CALGREEN
T24 1 CERTIFICATE OF COMPLIANCE FORMS
T24 2 CERTIFICATE OF COMPLIANCE FORMS
T24 3 RESIDENTIAL MEASURES SUMMARY
GRAND TOTAL: 21 1
P
L
A
N
N
I
N
G
1
S
T
P
C
R
E
S
U
B
M
I
T
T
A
L
1
0
/
2
3
/
2
0
2
4
2
B
U
I
L
D
I
N
G
S
U
B
M
I
T
T
A
L
1
1
/
1
9
/
2
0
2
4
Scale:3/32" = 1'-0"1 SP - EXISTING
Scale:3/32" = 1'-0"2 SP - PROPOSED
NORTH NOTES:
-ALL UTILITY CABLES OR WIRES
BETWEEN THE PRIMARY RESIDENCE
AND THE DETACHED ADU SHALL BE
PLACED UNDERGROUND PER
SECTION 41-626 OF THE SAMC
-NO EASEMENTS LOCATED ON
PROPERTY
1513 S. BIRCH ST., SANTA ANA, CA 90727 -ADU
ADU / SFD = 622 SF/ 1121 SF = .55%
THE ADU/SFD RATIO IS FOR PARK & REC FEE PURPOSE
ONLY. THE APPLICANT IS RESPONSIBLE FOR THE GIVEN
SFR PERCENTAGE OF THE EXISTING PRIMARY
RESIDENCE; BUILDING SAFETY STAFF ARE NOT
RESPONSIBLE FOR THE ACCURACY OF THE GIVEN SFR
SF.
MECHANICAL, ELECTRICAL AND PLUMBING ARE NOT
PART OF THIS PLAN REVIEW AND APPROVAL. THE
BUILDING AND SAFETY DIVISION PLAN REVIEW DOES NOT
INCLUDE POTENTIAL ELECTRICAL, WATER, OR GAS
REVISIONS REQUIRED BY ANY NON-CITY UTILITY
COMPANY. IT IS SOLELY ON THE CONTRACTOR TO
ENSURE PROPOSED ADDITION OR ALTERATION CAN AND
WILL MEET UTILITY COMPANY REQUIREMENTS. MEP ARE
SUBJECT TO BUILDING FIELD INSPECTION.
Bldg #102122347
APPROVALS:
PLNG - C. Santana
BLDG - J, Lo
POLICE - B. Martin
PUBLIC WORKS - Y. Soto
ISSUED
DATE:
REVISIONS
DRAWINGS, SPECIFICATIONS AND OTHER VISUAL AIDS, AS
INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE
DRAFTER/DESIGNER WHETHER THE PROJECT FOR
WHICH THEY ARE MADE BE EXECUTED OR NOT, AND
THEY ARE NOT TO BE USED FOR ANY OTHER SITE THAN
THE ONE FOR WHICH THEY ARE PREPARED, EXCEPT BY
AGREEMENT IN WRITING.
NO
.
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
DRAFTER/DESIGNER:
LUIS N OROZCO
562.661.9281
LUIS.OROZCO.A@LIVE.COM
DATE:
G102
GENERAL NOTES
PR
O
P
E
R
T
Y
O
W
N
E
R
:
S
I
L
V
I
A
T
O
R
R
E
S
15
1
1
S
.
B
I
R
C
H
S
T
.
SA
N
T
A
A
N
A
,
C
A
9
0
7
2
7
GA
R
A
G
E
C
O
N
V
E
R
S
I
O
N
T
O
A
N
AC
C
E
S
S
O
R
Y
D
W
E
L
L
I
N
G
U
N
I
T
09/10/2024
GENERAL NOTES:
1) ALL MEASUREMENTS AND JOB CONDITIONS ARE SUBJECT TO VERIFICATION AND
ANY DISCREPANCIES MUST BE CALLED ATTENTION TO THE DESIGNER IMMEDIATELY.
2) ANY ERRORS, AMBIGUITIES AND OMISSIONS IN DRAWINGS AND SPECIFICATIONS
SHALL BE REPORTED TO DESIGNER FOR CORRECTIONS BEFORE ANY PART OF THE
WORK IS STARTED. UNLESS EXPRESSLY STIPULATED, NO ADDITIONAL ALLOWANCE
WILL BE MADE IN FAVOR OF THE CONTRACTOR/SUBCONTRACTOR AND/OR THE
MANUFACTURER BY VIRTUE OF ERRORS, AMBIGUITIES AND/OR OMISSIONS WHICH
SHOULD HAVE BEEN DISCOVERED DURING THE PREPARATION OF BID ESTIMATE AND
DIRECTED TO THE ATTENTION OF THE DESIGNER IN A TIMELY MANNER.
3) IF DUE TO THE NATURE OF MATERIAL OR METHOD OF CONSTRUCTION DETAILS AS
SHOWN ON DRAWINGS OR SPECIFIED CANNOT BE SATISFACTORILY ACHIEVED, THE
CONTRACTOR SHALL IMMEDIATELY ADVISE THE DESIGNER, IN WRITING, AND REQUEST
AN ADJUSTMENT CONSIDERED NECESSARY FOR THE PROPER EXECUTION OF WORK.
THIS REQUEST SHALL BE MADE BEFORE ANY MATERIAL IS ORDERED OR FABRICATED.
ANY UNSATISFACTORY WORK THAT DEVELOPS DURING FABRICATION OR
INSTALLATION SHALL BE CORRECTED AT THE CONTRACTOR'S EXPENSE.
4) THE CONTRACTOR AND SUB-CONTRACTORS SHALL COORDINATE THEIR WORK
WITH ADJACENT WORK AND SUB-CONTRACTORS AND COOPERATE WITH EACH OTHER
SO AS TO FACILITATE GENERAL PROGRESS OF WORK. EACH TRADE SHALL AFFORD
OTHER TRADES OTHER REASONABLE OPPORTUNITY FOR INSTALLATION OF THEIR
WORK AND FOR STORAGE OF THEIR MATERIALS. THE CONTRACTOR SHALL
COORDINATE ALL WORK AT THE SITE.
5) SHOULD THE DRAWINGS DISAGREE WITH THEMSELVES OR THE SPECIFICATIONS,
THE BETTER QUALITY OR THE GREATEST QUANTITY OF WORK OR MATERIALS SHALL
BE INCLUDED IN THE PROPOSAL, AND UNLESS OTHERWISE ORDERED BY THE
DESIGNER, IN WRITING, SHALL BE PERFORMED OR FURNISHED.
6) ALL WORK SHALL BE IN COMPLIANCE WITH APPLICABLE ORDINANCES AND
REGULATIONS OF ALL PUBLIC AUTHORITIES BEARING THE PERFORMANCE OF THE
WORK.
7) IF THE CONTRACT DOCUMENTS ARE AT VARIANCE WITH THE ABOVE, THE
CONTRACTOR SHALL NOTIFY THE DESIGNER PRIOR TO THE PERFORMANCE OF SUCH
WORK, AND ANY NECESSARY ADJUSTMENTS SHALL BE MADE BY APPROPRIATE
MODIFICATION.
8) THE CONSTRUCTION DOCUMENTS ARE NOT TO BE REPRODUCED OR USED FOR
ANY OTHER PURPOSE THAN ORIGINALLY INTENDED EXCEPT AS AUTHORIZED IN
WRITING BY THE DESIGNER.
9) THE ABOVE NOTES ARE TO BE SUPERSEDED WHEN CONSTRUCTION DOCUMENTS
ARE ACCOMPANIED BY "INSTRUCTIONS TO BIDDERS" AND/OR "GENERAL CONDITIONS".
10) THE CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL EXISTING CONDITIONS
AND DIMENSIONS. THE CONTRACTOR SHALL CHECK ALL DIMENSIONS AND NOTIFY THE
DESIGNER OF ANY DISCREPANCIES BEFORE COMMENCING WORK.
11) ALL FOOTINGS, NAILING, REINFORCING, ANCHOR BOLTS, STRAPS AND
STRUCTURAL MEMBERS SHALL BE IN COMPLIANCE WITH THE UNIFORM BUILDING
CODE (UBC), OTHER APPLICABLE CODES, AND AS SHOWN ON STRUCTURAL
DRAWINGS.
12) THE CONTRACTOR SHALL PROVIDE ALL MATERIALS, LABOR, EQUIPMENT,
TRANSPORTATION AND SERVICES NECESSARY FOR COMPLETION OF WORK EXCEPT
AS PROVIDED BY OWNER AND AS OTHERWISE NOTED.
13) THE CONTRACTOR SHALL PROVIDE FOR ALL NECESSARY PERMITS AND
INSPECTIONS, OTHER THAN THE PLAN CHECK AND BUILDING PERMIT FEES TO BE
PROVIDED BY THE OWNER. SUB-CONTRACTORS WHOSE WORK IS NOT NORMALLY
COVERED BY THE BUILDING PERMIT, SUCH AS, BUT NOT LIMITED TO, ELECTRICAL,
MECHANICAL, PLUMBING, OFF-SITE WORK AND SO FORTH, SHALL OBTAIN AND PAY
FOR THEIR APPROPRIATE PERMITS.
14) THE CONTRACTOR SHALL MAINTAIN LIABILITY INSURANCE TO PROTECT
HIMSELF/HERSELF AND HOLD THE OWNER AND THE DESIGNER HARMLESS FROM ANY
AND ALL CLAIMS FOR DAMAGES FOR PERSONAL OR BODILY INJURY OR DEATH OR FOR
PROPERTY DAMAGE DURING THE COURSE OF THE CONTRACT (FIRE INSURANCE
SHALL BE MAINTAINED BY THE OWNER).
15) CONTRACTOR SHALL PROVIDE SUFFICIENT MEANS FOR PROTECTING THE PUBLIC
FROM INJURY AS WELL AS ADJACENT PROPERTY AND VEGETATION FROM DAMAGE.
16) THE CONTRACTOR SHALL COORDINATE AND SCHEDULE ALL WORK WITH THE
APPROVAL OF THE OWNER AND WITH MINIMUM DISRUPTION. ANY DEMOLITION SHALL
BE KEPT TO A MINIMUM AND ALL DEBRIS SHALL BE REMOVED FROM THE SITE. THE
OWNER SHALL BE CONSULTED BEFORE ANY BUILDING SERVICE IS TEMPORARILY CUT
OFF. TEMPORARY RE-ROUTE UTILITIES REQUIRED BY THE OWNER FOR CONTINUOUS
SERVICE.
17) ALL DUST AND NOISE CREATED BY THE WORK SHALL BE KEPT TO A MINIMUM.
18) UPON COMPLETION OF THE DAILY WORK AND COMPLETION OF ALL WORK, ALL
WORK AREAS SHALL BE LEFT BROOM CLEAN AND ALL DEBRIS REMOVED FROM THE
SITE BY THE CONTRACTOR. DURING CONSTRUCTION THE CONTRACTOR SHALL
REMOVE AND DISPOSE OF ANY DEBRIS OR UNAPPROVED MATERIALS. THE SITE SHALL
BE KEPT IN A NEAT AND SAFE CONDITION.
19) CONTRACTOR SHALL PROVIDE SUFFICIENT MEANS FOR PROTECTING EXPOSED
FINISHES, NEW CONSTRUCTION AND MATERIALS FROM DAMAGE BY WEATHER OR
VANDALS FOR THE COURSE OF THE PROJECT. CONTRACTOR SHALL PROVIDE ALL
BARRICADES, FENCES AND ANY OTHER ITEMS REQUIRED BY LOCAL ORDINANCES OR
CODES.
20) ALL WEATHER EXPOSED JOINTS SHALL BE FLASHED AND SET IN MASTIC.
21) CAULK BETWEEN ALL PLASTER STOPS.
22) INSTALL ALL CLOSING REQUIRED TO PROVIDE COMPLETE WATERTIGHT
PROTECTION. FLASH DECK TO ROOF INTERSECTIONS, WALL TO ROOF INTERSECTIONS
AND ALL VERTICAL TO HORIZONTAL SURFACES. FLASH AND COUNTER FLASH AND SET
IN MASTIC TO PROVIDE FOR A WATERTIGHT CONNECTION. ALL SHEET METAL SHALL BE
GALVANIZED IRON UNLESS OTHERWISE NOTED. GAUGES AND CONFIGURATIONS OR
ASSEMBLIES SHALL BE AS RECOMMENDED BY SMACNA.
23) WOOD STAIRS SHALL BE HOUSED, WEDGED AND FITTED WITH GLUE BLOCKS.
24) FIRESTOPS: FIRESTOPPING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED
DRAFT OPENINGS (BOTH VERTICAL & HORIZONTAL) AND SHALL FORM AN EFFECTIVE
BARRIER BETWEEN STORIES AND BETWEEN A TOP STORY AND A ROOF SPACE. IT
SHALL BE USED IN SPECIFIC LOCATIONS, AS FOLLOWS:
1 IN EXTERIOR OR INTERIOR STUD WALLS, AT CEILINGS AND FLOOR LEVELS.
2 IN ALL STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES, SO PLACED
THAT THE MAXIMUM DIMENSION OF ANY CONCEALED SPACE IS NOT OVER 10 FEET.
3 BETWEEN STAIR STRINGERS AT TOP AND BOTTOM AND BETW EEN STUDS ALONG
AND IN LINE WITH RUN OF STAIR ADJOINING STUD WALLS AND PARTITIONS.
4 AROUND TOP, BOTTOM, SIDES AND ENDS OF SLIDING DOOR POCKETS.
5 IN SPACES BETWEEN CHIMNEYS AND FLOOR OR CEILING FRAMING, LOOSE NON-
COMBUSTIBLE SUPPORTS, OR A METAL COLLAR TIGHTLY FITTED TO THE CHIMNEY AND
NAILED TO THE WOOD FRAMING MAY BE USED.
6 ANY OTHER LOCATIONS NOT SPECIFICALLY MENTIONED ABOVE, SUCH AS HOLES
FOR PIPES, SHAFTING, BEHIND FURRING STRIPS AND SIMILAR PLACES WHICH COULD
AFFORD A PASSAGE FOR FLAMES.
25) FIRESTOPS WHEN OF WOOD SHALL BE OF 2 INCH NOMINAL THICKNESS. IF THE
WIDTH OF THE OPENING IS SUCH THAT MORE THAN ONE PIECE OF LUMBER IS
NECESSARY, THERE SHALL BE TWO THICKNESSES OF 1 INCH PLYWOOD WITH JOINTS
BACKED BY 3/4" PLYWOOD.
26) FIRE STOPS MAY ALSO BE OF GYPSUM BOARD, CEMENT ASBESTOS BOARD,
MINERAL WOOL OR OTHER APPROVED NON-COMBUSTIBLE MATERIALS SECURELY
FASTENED IN PLACE.
27) THE CONTRACTOR SHALL PROVIDE ALL SHORING AND BRACING REQUIRED TO
ADEQUATELY PROTECT PERSONNEL AND PROPERTY AND TO INSURE SAFETY OF THE
STRUCTURE THROUGHOUT THE CONSTRUCTION PERIOD. THE CONTRACTOR SHALL
PROVIDE, AT HIS OWN EXPENSE, ALL ERECTION BRACING AND DRAWINGS REQUIRED
BY LAW AND BY SAFE CONSTRUCTION PRACTICES.
28) SPECIFIC NOTES AND DETAILS SHALL GOVERN OVER GENERAL NOTES AND
TYPICAL DETAILS. SUBSTITUTION MAY BE MADE FOR PROPRIETARY ITEMS NOTED,
SUBJECT TO PRIOR REVIEW AND APPROVAL IN WRITING BY THE DESIGNER.
6) GENERAL CONTRACTOR SHALL PROVIDE FIRE EXTINGUISHERS AS REQUIRED BY
THE FIRE DEPARTMENT.
7) ALL SHEET METAL, COPING, FLASHING ETC. SHALL BE MINIMUM 24 GAUGE G.I.
8) STUCCO - ALL HORIZONTAL SURFACE METAL DRIP SCREEDS @ ALL BALCONIES,
PROJECTIONS AND ETC., (TYPICAL).
UTILITIES, PLUMBING, DRAINAGE, ETC.
1) CONTRACTOR SHALL COORDINATE WITH REPRESENTATIVES OF LOCAL UTILITIES,
INCLUDING GAS, WATER, POWER, SEWER, TELEPHONE AND T.V. TO VERIFY AVAILABLE
SERVICE AND, IF APPLICABLE, TO ESTABLISH TEMPORARY SERVICE. FINDINGS SHALL
BE INDICATED ON THE RECORD DRAWINGS.
2) CONTRACTOR/SUB-CONTRACTOR SHALL RE-ROUTE ANY EXISTING UTILITY LINES,
CONDUITS OR EQUIPMENT IN CONFLICT WITH NEW CONSTRUCTION AND SHALL NOTE
SUCH RE-ROUTING ON THE RECORD DRAWINGS.
3) CONTRACTOR/SUB-CONTRACTOR SHALL PROVIDE AND INSTALL NEW
UNDERGROUND WATER AND GAS SUPPLY LINES AND UPGRADES AS REQUIRED AND
VERIFY THAT METER, MAIN AND LINE SIZES ARE ADEQUATE TO PROVIDE ACCEPTABLE
PRESSURE AND VOLUME OF NEW CONSTRUCTION. CONTRACTOR MUST VERIFY IN
FIELD PRIOR TO BID SUBMITTAL.
4) CONTRACTOR SHALL PROVIDE NEW MAIN UNDERGROUND SEWER LINE AND NEW
WASTE LINES OF SUFFICIENT SIZE AS REQUIRED, INCLUDING ACCESSIBLE CLEANOUTS
AT CONNECTIONS, BENDS OR ELSEWHERE AS REQUIRED BY CODE. CONTRACTOR
MUST VERIFY IN FIELD PRIOR TO BID SUBMITTAL.
5) UNLESS OTHERWISE NOTED OR REQUIRED BY CODE, ALL UNDERGROUND STORM
DRAIN LINES SHALL BE PVC SCHEDULE 40 MINIMUM 4" DIAMETER OR GREATER AS
REQUIRED TO HANDLE LOAD. ALL CONNECTIONS SHALL BE PROPERLY JOINED AND
SEALED SO THAT THEY ARE WATERTIGHT.
N/A 6) CATCH BASINS SHALL BE PROVIDED WITH CAST IRON GRILLS WHERE
INDICATED ON PLANS OR REQUIRED BY JOB SITE CONDITIONS.
7) FLUSH OUT ALL NEW WATER SUPPLY LINES PRIOR TO CONNECTING FIXTURES.
7) DRAINAGE SHALL NOT FLOW OVER PUBLIC PROPERTY OR ACROSS ADJACENT
PRIVATE PROPERTY (UBC 2907(d) 5, 3027 (e) , 7012)
N/A 9) DRY STANDPIPE LOCATIONS SHALL BE APPROVED BY FIRE INSPECTOR PRIOR
TO INSTALLATION.
10) ALL COPPER PIPING SHALL BE TYPE "L".
11) REPLACE ALL EXISTING GALVANIZED PIPES WITH COPPER PIPING TYPE "L".
ELECTRICAL
1. UNLESS OTHERWISE NOTED, ALL CONDUITS SHALL BE CONCEALED IN STRUCTURE,
ATTIC SPACES OR UNDERGROUND. ANY EXCEPTIONS SHALL BE AUTHORIZED BY THE
DESIGNER.
2. CONTRACTOR SHALL PROVIDE NEW METERS AND PANELS, BREAKERS, CIRCUITS,
ETC. CONTRACTOR SHALL CONFIRM ALL ELECTRICAL LOADS AND REQUIREMENTS FOR
APPLIANCES, HEATING AND VENTILATION SYSTEMS AND OTHER ELECTRICAL
EQUIPMENT AND FIXTURES PRIOR TO PROVIDING NEW SERVICE. CONTRACTOR WILL
CONFIRM ABOVE REQUIREMENTS PRIOR TO SUBMITTING BID.
3. CONTRACTOR SHALL VERIFY CLEARANCES FOR ALL RECESSED FIXTURES AND
ADVISE DESIGNER OF ANY CONFLICTS PRIOR TO ORDERING.
4. CONTRACTOR SHALL CONFIRM FIXTURE TRIM SELECTION AND FINISH OPTIONS
WITH DESIGNER PRIOR TO ORDERING.
5. ALL WIRING SHALL BE COPPER
6. CONTRACTOR SHALL CONFIRM MATERIAL AND COLOR OF ALL SWITCHES, OUTLETS
AND COVER PLATES WITH DESIGNER PRIOR TO ORDERING.
7. CONTRACTOR SHALL PROVIDE TITLE 24, FORM 5, IF REQUIRED.
8. LIGHT CONTROLS SHALL BE 36" TO CENTER ABOVE FINISHED FLOOR UNLESS
NOTED OTHERWISE. LIGHT CONTROLS SHALL BE 48" TO CENTER ABOVE FINISHED
FLOOR FOR ADA REQUIRED SPACES. (ADA N/A)
9. ALL WALL DUPLEX RECEPTACLES, TELEPHONE, T.V. AND OTHER OUTLETS SHALL BE
MOUNTED 1'-0" TO CENTER ABOVE FINISHED FLOOR, EXCEPT AT COUNTER TOPS AND
WHERE OTHERWISE NOTED. ALL WALL DUPLEX RECEPTACLES, TELEPHONE, T.V. AND
OTHER OUTLETS SHALL BE MOUNTED 1'-3" TO CENTER ABOVE FINISHED FLOOR, FOR
ADA REQUIRED SPACES EXCEPT AT COUNTER TOPS AND WHERE OTHERWISE NOTED.
10.GROUND FAULT INTERRUPTER REQUIRED FOR ALL EXTERIOR OUTLETS,
BATHROOMS, TEMPORARY PANELS AND OTHER WET AREAS AS REQUIRED BY CODE.
11.DIMMERS SHALL BE SWITCH OR SLIDE TYPE CONTINUOUS DIMMERS. VERIFY
SELECTION WITH DESIGNER PRIOR TO ORDERING.
12.EVERY BEDROOM AND HALLWAY TO A BEDROOM SHALL BE PROVIDED WITH SMOKE
DETECTORS CONFORMING TO UBC STANDARD 43-C. SMOKE DETECTORS SHALL BE
MOUNTED ON THE CEILING OR THE WALL AT A POINT CENTRALLY LOCATED IN THE
CORRIDOR OR AREA GIVING ACCESS TO ROOMS USED FOR SLEEPING PURPOSES.
13.N/A IN AN EFFICIENCY DWELLING UNIT, THE DETECTOR SHALL BE LOCATED ON THE
CEILING OF THE MAIN ROOM. WHERE SLEEPING ROOMS ARE ON AN UPPER LEVEL, A
DETECTOR SHALL BE PLACED AT THE CENTER OF THE CEILING DIRECTLY ABOVE THE
STAIRWAY. PROVIDE SMOKE DETECTORS AT WALL OR CEILING IN ALL SLEEPING
ROOMS.
14.ALL SMOKE DETECTORS SHALL BE LOCATED IN ACCORDANCE WITH APPROVED
MANUFACTURER'S INSTRUCTIONS. WHEN ACTUATED, THE DETECTOR SHALL PROVIDE
AN ALARM IN THE DWELLING UNIT. CONFIRM TYPE AND LOCATIONS OF ALL DEVISES
WITH DESIGNER PRIOR TO ORDERING AND WIRING FOR UNIT.
15.ALL WORK SHALL INCLUDE MATERIALS, EQUIPMENT AND ALL LABOR REQUIRED TO
COMPLETE "ELECTRICAL" WORK AS SHOWN ON THE DRAWINGS AND HEREIN
SPECIFIED.
16.ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH THE CITY OF LOS
ANGELES'S ELECTRICAL CODE, CURRENT RULES OF THE NATIONAL ELECTRICAL
CODE, NATIONAL BOARD OF FIRE UNDERWRITERS, AND WITH ANY PREVAILING RULES
AND REGULATIONS PERTAINING TO ADEQUATE PROTECTION AND/OR GUARDING OF
ANY MOVING PARTS OR OTHERWISE OTHER HAZARDOUS LOCATIONS. MATERIALS
SHALL COMPLY WITH UNDERWRITERS LABORATORIES REQUIREMENTS.
17.VERIFY LOCATION OF ALL OUTLETS, SWITCHES, PANEL BOXES, LIGHTING FIXTURES,
BUZZERS, INTERCOMS, SMOKE DETECTORS (AND ANY OTHER VISIBLE CONTROLS OR
ELECTRICAL EQUIPMENT) WITH DESIGNER PRIOR TO INSTALLATION.
18.ALL TOGGLE SWITCHES AND SWITCH PLATES, CONVENIENCE RECEPTACLES AND
COVER PLATES, SMOKE DETECTORS AND BUZZERS SHALL BE WHITE IN COLOR
UNLESS OTHERWISE NOTED OR DIRECTED BY OWNER OR DESIGNER. CONTRACTOR
SHALL PROVIDE SAMPLE TO DESIGNER PRIOR TO ORDERING.
N/A 19. PROVIDE EMERGENCY POWER
SECURITY NOTES:
1) EXTERIOR DOORS, DOORS BETWEEN GARAGE AND HOUSE, WINDOWS AND THEIR
HARDWARE SHALL CONFORM TO CURRENT EDITION OF THE UBC.
2) WINDOWS AND OPENINGS WITHIN 12" OF GROUND LEVEL AND WITH OVER 96
SQUARE FEET IN AREA ARE DEEMED "ACCESSIBLE". GLAZING AND GLAZED
ASSEMBLIES FOR "ACCESSIBLE" OPENINGS SHALL BE CERTIFIED AS MEETING TEST
PROVISIONS OF UBC 41-2.
3) LOUVERED WINDOWS ARE NOT PERMITTED IN "ACCESSIBLE" AREAS OR WITHIN 6'
OF ANY BALCONY, LANDING OR PORCH.
4) WINDOWS SHALL BE A MINIMUM OF 40" FROM THE DOOR LOCK WHEN THE DOOR IS
IN THE CLOSED POSITION.
5) DOOR LITES AND WINDOWS WITHIN 40" OF THE LOCKING DEVISE OF THE DOOR
SHALL BE FULLY TEMPERED OR APPROVED BURGLARY RESISTANT.
6) A SINGLE SWINGING DOOR, ACTIVE LEAF OF A PAIR OF DOORS OR THE BOTTOM
LEAF OF DUTCH DOORS, SHALL BE EQUIPPED WITH A DEADBOLT AND A DEADLOCKING
LATCH, BOTH KEY OPERATED FROM THE OUTSIDE.
7) JAMBS SHALL BE INSTALLED WITH SOLID BACKING FOR A 6" VERTICAL DISTANCE ON
EACH SIDE OF THE LOCK STRIKE AREA.
8) TRIMMERS SHALL BE FULL DOOR LENGTH WITH SOLID BACKING AGAINST SOLE AND
HEADER PLATES.
9) HORIZONTAL BLOCKING SHALL BE PLACED BETWEEN STUDS AT LOCK STRIKE
HEIGHT FOR 3 STUD SPACES.
10) STRIKE PLATES SHALL BE A MINIMUM 16 US GAUGE STEEL, BRONZE OR BRASS AND
SECURED BY A MINIMUM OF (2) 2" LENGTH SCREWS.
11) DOUBLE DOORS, IN-ACTIVE LEAF, SHALL BE SECURED WITH BOTH HEAD AND BASE
FLUSH BOLTS WITH A MINIMUM 5/8" EMBEDMENT.
12) DOOR(S) WITH PANIC HARDWARE SHALL HAVE TWO LOCKING POINTS OR BE
EQUIPPED WITH .125 THICK 2" WIDE ASTRAGAL.
13) SWINGING DOORS ARE SECURITY OPENINGS. THE FOLLOWING ARE MINIMUM
REQUIREMENTS. OTHER NOTES AND DETAILS SHALL SUPERSEDE WHEN EQUAL TO OR
MORE SECURE THAN THESE REQUIREMENTS. SEE DOOR AND WINDOW SCHEDULES.
1 INSTALL DEAD LOCKING LATCHES.
2 INSTALL LOCK THAT IS KEY OPERATED FROM EXTERIOR AND OPENABLE FROM
INTERIOR WITHOUT KEY, OR SPECIAL EFFORT OR SPECIAL KNOWLEDGE.
3 DOOR STOPS OF THE IN-SWINGING DOORS SHALL BE OF A ONE-PIECE
CONSTRUCTION WITH THE JAMB OR JOINTED BY RABBET TO THE JAMB.
4 ALL PIN-TYPE HINGES WHICH ARE ACCESSIBLE FROM OUTSIDE THE SECURED
AREAS WHEN THE DOOR IS CLOSED SHALL HAVE NON-REMOVABLE HINGE PINS. IN
ADDITION THEY SHALL HAVE THE MINIMUM 1/4" DIAMETER STEEL JAMB STUDS WITH
1/4" MINIMUM PROJECTION UNLESS THE HINGES ARE SHAPED TO PREVENT THE
REMOVAL OF THE DOOR IF THE HINGES ARE REMOVED.
5 THE STRIKE PLATE FOR LATCHES AND THE HOLDING DEVICE FOR PROJECTING
DEADBOLTS IN WOOD CONSTRUCTION SHALL BE SECURED TO THE JAMB AND THE
WALL FRAMING WITH SCREWS NOT LESS THAN 2 1/4" IN LENGTH.
6 DEADBOLTS SHALL CONTAIN HARDENED INSERTS, HAVE CYLINDER GUARD AND
MINIMUM 6 PIN TUMBLER LOCKS, AND USE MINIMUM 1/4" DIAMETER CONNECTING
SCREWS.
7 STRAIGHT DEADBOLTS SHALL HAVE A MINIMUM THROW OF 1" AND AN EMBEDMENT
OF NOT LESS THAN 5/8" INTO THE STRIKE.
8 A HOOK SHAPED OR AN EXPANDING-LUG DEADBOLT SHALL HAVE A MINIMUM
THROW OF 3/4".
9 WOOD FLUSH-TYPE DOORS SHALL BE 1 3/4" THICK MINIMUM WITH A SOLID CORE OF
WOOD, OR PARTICLE BOARD OF 25 PCF DENSITY. SWINGING WOOD DOORS SHALL
COMPLY WITH SECTION 6709 (A) FOR THICKNESS AND CONSTRUCTION.
14) OVERHEAD AND SLIDING GARAGE DOORS SHALL BE SECURED WITH A CYLINDER
LOCK, PADLOCK WITH HARDENED STEEL SHACKLE, METAL SLIDE BAR BOLT OR
EQUIVALENT WHEN NOT OTHERWISE LOCKED BY ELECTRIC POWER OPERATION.
15) DOORS SHALL BE HUNG IN A TRUE VERTICAL PLANE WITHOUT WARP OR WIND AND
BE FITTED SO AS TO HAVE 1/16" CLEARANCE ABOVE THRESHOLDS WHERE DOORS
OPEN INTO ROOMS. OTHERWISE, CLEARANCE SHALL BE 3/8" ABOVE THE FLOORS. THE
CLEARANCE AT THE HINGE JAMB AND AT THE HEAD SHALL BE 3/32".
16) FINISH DEPTH OF BOTTOM RAIL AND INSTALLATION OF JAMB AND SADDLE SHALL
ACCOMMODATE FINISH FLOOR SURFACES.
SPECIFIC RESIDENTIAL BUILDING REQUIREMENTS:
1) ENTRANCE DOORS TO DWELLINGS AND RENTAL UNITS SHALL BE EQUIPPED WITH A
180 DEGREE WIDE ANGLE DOOR VIEWER OR VISION PANEL.
2) N/A HIGH CONTRASTING "STREET ADRESS NUMBERS" ARE REQUIRED ON BOTH
STREET AND ALLEY ACCESSES.
3) N/A ILLUMINATION OF ONE FOOT CANDLE OF LIGHT SHALL BE PROVIDED FOR
RESIDENTIAL BUILDING ACCESSORY AREAS AS FOLLOWS:
1 EXITWAYS, AISLES, PASSAGEWAYS AND RECESSES WITHIN THE BUILDING COMPLEX
DURING HOURS OF DARKNESS.
2 OPEN PARKING LOTS, GARAGES AND CARPORTS DURING HOURS OF DARKNESS.
4) N/A MULTIPLE UNIT COMPLEXES SHALL PLACE AN ILLUMINATED DIAGRAMMATIC
REPRESENTATION OF THE COMPLEX AT THE MAIN ENTRANCE WHICH SHOWS
LOCATION AND UNIT DESIGNATIONS WITHIN THE COMPLEX. INDIVIDUAL UNITS
REQUIRE A 4" HEIGHT I.D. DESIGNATION.(SEE ELECTRICAL ENGINERING PLANS)
ENERGY INSULATION REQUIREMENTS:
1) ALL SWINGING DOORS AND WINDOWS OPENING TO THE EXTERIOR OR TO
UNCONDITIONED AREAS SUCH AS GARAGES, SHALL BE FULLY WEATHER-STRIPPED,
GASKETED OR OTHERWISE TREATED TO LIMIT INFILTRATION. ALL MANUFACTURED
WINDOWS AND SLIDING GLASS DOORS SHALL MEET THE AIR INFILTRATION
STANDARDS OF THE CURRENT AMERICAN NATIONAL STANDARDS INSTITUTE (A.N.S.I.) A
134.1 TO 134.4 WHEN TESTED IN ACCORDANCE WITH ASTM E 283-73. WINDOWS AND
DOORS SHALL BE CERTIFIED AND LABELED.
1) ALL F.A.U. SYSTEMS EXHAUSTING AIR FROM THE BUILDING ENVELOPE TO THE
OUTSIDE SHALL BE PROVIDED WITH BACKDRAFT DAMPERS.
3) RE-CIRCULATING HOT WATER PIPING AND ALL PLUMBING PIPES SHALL BE FULLY
INSULATED THROUGHOUT TO PROVIDE MAXIMUM LOSS OF NOT MORE THAN (50)
BTU/HR. LINEAR FOOT FOR LARGER SIZES (T-20-1406C).
4) ALL GARAGE WALLS AND CEILINGS TO LIVING AREAS SHALL BE TREATED AS
EXTERIOR WALLS FOR INSULATION.
INSULATED.
6) ALL INSULATION SHALL BE APPROVED AND COMPLY WITH STATE STANDARDS.
7) THE CONTRACTOR SHALL SIGN AND POST IN THE STRUCTURE AN INSULATION
CERTIFICATION PRIOR TO THE FINISH INSPECTION. THE INSULATION CERTIFICATE
SHALL MEET THE STATE OF CALIFORNIA STANDARDS AS SHOWN IN THE DESIGN
MANUAL.
8) INSULATION IN WALLS SHALL BE R-19 (VERIFY)
INSULATION IN CEILINGS/ROOFS SHALL BE R-30, U.N.O. (VERIFY)
INSULATION IN FLOORS SHALL BE R-30, U.N.O. (VERIFY)
9) FIREPLACES SHALL MEET THE FOLLOWING REQUIREMENTS:
A. FIREBOX OPENINGS SHALL BE COVERED WITH A TIGHT FITTING
CLOSABLE METAL OR GLASS DOOR.
B. FIREBOX MUST HAVE AN OUTSIDE AIR INTAKE OF A MINIMUM AREA OF 6
SQUARE INCHES WITH AN OPENABLE DAMPER, WITH EXCEPTIONS FOR
CLIMATE ZONES 5,6,7,8,9,10,14 AND 15 IF THE FIREBOX IS NOT LOCATED
NEAR AN EXTERIOR WALL OR IN ANY CLIMATE ZONE IF THE FIREPLACE
WILL BE INSTALLED OVER CONCRETE SLAB FLOORING AWAY FROM AN
EXTERIOR WALL.
C. CONTINUOUS BURNING GAS PILOT LIGHTS ARE PROHIBITED.
D. FIREPLACES MUST HAVE A TIGHT FITTING FLUE DAMPER WITH READILY
ACCESSIBLE CONTROL.
E. PRE-FABRICATED FIREPLACES SHALL BE I.C.B.O. LISTED AND INSTALLED
PER MANUFACTURER'S SPECIFICATIONS.
10) INSULATION BLANKETS WITH A MINIMUM RATING OF R-12 MUST BE INSTALLED ON
WATER HEATERS.
11) INSULATION WITH A MINIMUM RATING OF R-3 MUST BE INSTALLED ON THE FIRST 5
FEET OF HOT WATER OUTLET PIPE IN UNCONDITIONED SPACE FOR A HOT WATER
HEATER.
12) GAS FIRED HOUSHOLD COOKING APPLIANCES, SHOWER HEADS AND FAUCETS
SHALL COMPLY WITH THE APPLIANCE EFFICIENCY STANDARDS.
13) FLUORESCENT LIGHT FIXTURES USED IN KITCHENS AND BATHROOMS SHALL HAVE
AN EFFICIENCY OF NOT LESS THAN 40 LUMENS PER WATT.
14) THE BUILDING DESIGN SHALL MEET THE REQUIREMENTS OF TITLE 24, PART 2,
CHAPTER 2-53.
15) GLAZING SHALL HAVE MAX. U-VALUE <0.75
16)
a) DOORS AND WINDOWS BETWEEN CONDITIONED AND UNCONDITIONED SPACES
SHALL BE FULLY WEATHERSTRIPPED (THIS INCLUDES DOORS BETWEEN RESIDENCE
AND GARAGE)
b) THE FOLLOWING OPENINGS IN THE EXTERIOR ENVELOPE OF THE BUILDING SHALL
BE CAULKED OR OTHERWISE SEALED TO LIMIT INFILTRATION:
i) EXTERIOR JOINTS AROUND WINDOW DOOR FRAMES, BETWEEN WALL SOLE
PLATE AND FLOORS AND BETWEEN EXTERIOR PANELS;
ii) OPENINGS FOR PLUMBING, ELECTRICAL AND GAS LINES IN WALLS, CEILINGS
AND FLOORS;
iii) OPENINGS IN THE ATTIC, SUCH AS THE POINT WHERE THE CEILINGS MEET
FIREPLACES.
a) EXHAUST FANS SHALL BE PROVIDED WITH BACKDRAFT DAMPERS OR AUTOMATIC
DAMPERS
b) DUCTS SHALL BE CONSTRUCTED, INSTALLED AND INSULATED ACCORDING TO
CHAPTER 6 OF THE CALIFORNIA MECHANICAL CODE.
c) THERMOSTATICALLY CONTROLLED HEATING AND COOLING SYSTEMS, EXCEPT
ELECTRIC HEAT PUMPS, SHALL HAVE AN AUTOMATIC THERMOSTAT SET POINTS FOR
AT LEAST TWO PERIODS WITHIN 24 HOURS.
d) ALL HEATING, VENTILATING, AIR CONDITIONING (HVAC) EQUIPMENT SHALL BE
CERTIFIED BY CALIFORNIA ENERGY COMMISSION.
e) WATER HEATERS SHALL BE CERTIFIED BY THE CALIFORNIA ENERGY COMMISSION.
f) WRAP STORAGE TYPE WATER HEATERS AND STORAGE AND BACK-UP TANKS FOR
SOLAR WATER HEATER SYSTEMS WITH MINIMUM R-12 INSULATION EXTERIOR AND
R-16 FOR INTERIOR
g) INSULATE PIPING IN UNCONDITIONED SPACES LEADING TO AND FROM WATER
HEATERS WITH MINIMUM R-4 INSULATION FOR A DISTANCE OF 5'-0" FROM THE
WATER HEATER.
h) GENERAL LIGHTING IN KITCHENS AND BATHROOMS SHALL HAVE AN EFFICIENCY OF
AT LEAST 40 LUMENS PER WATT.
17) INSULATION INSTALLER AND THE CONTRACTOR SHALL POST A SIGNED
CERTIFICATE OF COMPLIANCE IN A CONSPICUOUS LOCATION IN THE BUILDING. THIS
CERTIFICATE SHALL STATE THAT THE INSTALLATIONS AND MATERIALS CONFORM TO
THE APPROPRAITE SECTIONS OF THE CALIFORNIA ADMINISTRATIVE CODE, TITLES 20
AND 24 AND SHALL SPECIFY THE MANUFACTURER'S NAME AND MATERIAL
IDENTIFICATION, THE INSTALLED R-VALUE, AND WHEN LOOSE FILL IS INSTALLED,
SHALL STATE THE MINIMUM INSTALLED WEIGHT PER SQUARE FOOT CONSISTENT WITH
THE MANUFACTURER'S LABELED DENSITY FOR THE DESIRED R-VAULE.
18) MANUFACTURED DOORS AND WINDOWS SHALL BE CERTIFIED AND LABELED IN
COMPLIANCE WITH THE APPROPRIATE INFILTRATION STANDARDS.
19) REFER TO TITLE-24 SHEETS FOR ADDITIONAL INFORMATION.
SITE WORK:
CONTRACTOR SHALL REMOVE FROM SITE ALL DEBRIS AND VEGETATION AS NOTED
OR REQUIRED. FOLLOWING MAJOR REMOVAL WORK, PROVIDE FINAL CLEARANCE AND
CLEAN UP BY SCARIFYING ALL EARTH SURFACE ON ENTIRE SITE OR AS NOTED ON
SITE PLAN. REMOVE REFUSE AND DEBRIS GATHERED BY PROCESS FROM SITE.
WHERE EXCESSIVE DUST OCCURS DURING EARTH MOVING OPERATIONS, PROVIDE
SUFFICIENT SPRINKLERING OF THE AREA.
THE CONTRACTOR SHALL PROVIDE AND COORDINATE SITE PLUMBING, DRAINAGE,
ELECTRICAL, TELEPHONE ETC., WORK TO PROVIDE A COMPLETE WORKING AND
OPERATING SYSTEM.
SEE SHOP DRAWINGS BY CONTRACTOR AND/OR SUB-CONTRACTOR AND
SPECIFICATIONS FOR BUILDING WORK. CONTRACTOR WILL PROVIDE ALL CABINET
SHOP DRAWINGS.
THE CONTRACTOR IS RESPONSIBLE FOR PLACING THE BUILDING ACCURATELY ON THE
BUILDING SITE.
CONTRACTOR SHALL PERFORM ALL EXCAVATING REQUIRED AS SHOWN ON THE
DRAWINGS OR OTHERWISE SPECIFIED BY THE STRUCTURAL DRAWINGS AND/OR THE
SOILS REPORT. EXCAVATIONS SHALL BE KEPT FREE OF STANDING WATER AND SHALL
BE LEVEL AS REQUIRED.
ALL FOOTINGS SHALL BE BELOW UNDISTURBED NATURAL SOIL OR APPROVED
COMPACTED FILL.
EXCAVATIONS, FILLING, BACKFILLING AND GRADING:
NOTE: STRUCTURAL AND GEOLOGICAL NOTES AND DRAWINGS SHALL SUPERSED THE
FOLLOWING.
EXCAVATIONS SHALL BE MADE TO THE DIMENSIONS AND ELEVATIONS INDICATED ON
THE DRAWINGS OR AS REQUIRED FOR THE BUILDING.
IF UNSUITABLE BEARING IS ENCOUNTERED AT THE ELEVATIONS INDICATED,
EXCAVATION SHALL BE CARRIED TO SUCH GREATER DEPTHS AS DIRECTED BY THE
SOILS ENGINEER AND/OR THE STRUCTURAL ENGINEER, THE CONTRACT PRICE SHALL
BE ADJUSTED ACCORDINGLY. EXCAVATIONS SHALL EXTEND A SUFFICIENT DISTANCE
FROM WALLS AND FOOTINGS TO ALLOW FOR FORMS, INSULATION, WATERPROOFING,
INSTALLATION OF SERVICES AND FOR INSPECTION.
BACKFILL SHALL BE PLACED AFTER FOUNDATIONS, WALLS AND SLABS HAVE ATTAINED
SUFFICIENT STRENGTH TO SUPPORT LATERAL SOIL PRESSURES.
CONTRACTOR SHALL REFER TO STRUCTURAL DRAWINGS AND SOILS REPORT FOR
DEPTH OF FOOTINGS AND OTHER PERTINENT INFORMATION.
CONTRACTOR SHALL PERFORM REQUIREMENTS FOR EXCAVATIONS CONTAINED IN
THE STATE CONSTRUCTION SAFETY ORDERS ENFORCED BY THE STATE DIVISION OF
INDUSTRIAL SAFETY.
APPROVAL FROM DEPARTMENT OF GENERAL SERVICES AND PUBLIC WORKS SHALL BE
OBTAINED AS REQUIRED FOR EXCAVATIONS THAT WOULD REMOVE LATERAL
SUPPORT OF THE PUBLIC WAY.
SHORING, UNDERPINNING, AND/OR SLOT CUTTING OR OTHER METHODS SHALL BE
PERFORMED UNDER THE INSPECTION AND APPROVAL OF THE FOUNDATION ENGINEER
AS REQUIRED.
CITY GRADING INSPECTOR SHALL INSPECT AND APPROVE BOTTOM OF EXCAVATIONS
AS REQUIRED PRIOR TO BACKFILL INSTALLATION.
CONTRACTOR SHALL GIVE NOTICE IN A TIMELY MANNER TO ADJACENT PROPERTY
OWNERS REGARDING PROTECTION OF THEIR PROPERTY AND STRUCTURES AS
NECESSARY DUE TO EXCAVATION AND CONSTRUCTION.
29) UTILITIES: CONTRACTORS TO VERIFY WITH WATER, GAS, ELECTRIC, TELEPHONE,
AND SEWER COMPANIES FOR LOCATION OF UTILITIES AND PROVIDE IN BID COSTS
FOR INSTALLATION AND CONNECTION FOR WORKING ORDER. CONTRACTOR TO
PROVIDE IN BID CONNECTION FEES FOR ALL UTILITIES.
30) CONTRACTOR SHALL PROVIDE TEMPORARY SANITARY FACILITIES DURING
CONSTRUCTION.
31) T.V. ANTENNA CROSS ARMS OR ANY OTHER SIMILAR OBSTRUCTIONS SHALL BE
LOCATED 7'-0" MINIMUM ABOVE THE ROOF SURFACE.
32) CONDUCT ALL ROOF DRAINAGE TO STORM DRAIN OR EQUIVALENT MEANS IN A
NON-EROSIVE MANNER.
33) NO TRENCHES OR EXCAVATIONS 5'-0" OR MORE IN DEPTH INTO WHICH A PERSON
IS REQUIRED TO DESCEND SHALL BE PERMITTED UNLESS THE NECESSARY PERMIT
FROM EACH STATE OF CALIFORNIA DIVISION OF INDUSTRIAL SAFETY IS FIRST
OBTAINED.
34) GLASS DOORS, SIDELIGHTS WITHIN 40" OF LOCK, AND ALL GLAZED OPENINGS
WITHIN 18" OF ADJACENT FLOOR SHALL BE APPROVED FOR IMPACT HAZARD.
(TEMPERED GLASS)
35) ALL GLAZING SHALL COMPLY WITH CITY REQUIREMENTS OF THE CURRENT
UNIFORM BUILDING CODE (UBC).
36) ON ALL DRAWINGS, DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE.
37) ALL WATER HEATERS SHALL BE STRAPPED FOR LATERAL SUPPORT.
38) SHOWER WALLS OVER BATHTUBS SHALL BE OF APPROVED NON-ABSORBENT
WATERPROOF MATERIAL TO A HEIGHT OF 5'-0" MINIMUM ABOVE THE TUB UNLESS
NOTED OTHERWISE. WAINSCOT SHALL ALSO EXTEND FULL HEIGHT AND BEYOND THE
FACE OF THE TUB OR SHOWER PAN. SHOWER WALLS AND SHOWER DOORS SHALL BE
6'-0" ABOVE FLOOR.
39) ALL SHOWER AND SHOWER-TUB ENCLOSURES SHALL BE OF SHATTER-PROOF
GLASS. (TEMPERED GLASS) "FRAMELESS" U.N.O
40) ACCESS PANEL: PROVIDE A MINIMUM 12"X12" AT EACH TUB. SEE DRAWINGS FOR
ANY SPECIAL ACCESS PANELS FOR ACCESS TO "WHIRLPOOL" TYPE TUBS.
41) ALL TILED BATHROOM FLOORS SHALL HAVE ONE LAYER OF 30# FELT (BUILDING
PAPER) SET IN WATERPROOF CEMENT AND TURNED 2" UP THE WALLS OR 2" ABOVE
TILE WAINSCOT .
42) PROVIDE MECHANICAL VENTILATION SYSTEM IN INTERIOR BATHROOMS AND
LAUNDRY ROOM TO FURNISH FIVE AIR CHANGES PER HOUR DIRECT TO OUTSIDE.
43) INSIDE FINISHED DIMENSIONS OF SHOWER AND/OR TOILET COMPARTMENT MUST
BE 32" MINIMUM WIDTH AND 24" CLEAR IN FRONT OF TOILET.
44) PLUMBING CLEANOUTS SHALL NOT BE VISIBLE FROM LIVING, DINING AND HALLS
EXCEPT AS NOTED ON PLANS.
45) ALL PORTIONS OF DRAIN PIPING SHALL BE CAST IRON UNLESS NOTED OTHERWISE.
46) PLASTERED SURFACE ON WALLS, CEILINGS AND ROOF SOFFITS EXPOSED TO THE
WEATHER SHALL HAVE EXTERIOR LATH AND PLASTER CONFORMING TO SECTION 4708
& 4706 OF THE UBC RESPECTIVELY.
47) INSPECTION IS REQUIRED FOR ALL INTERIOR AND EXTERIOR IN-PLACE LATH
AND/OR WALLBOARD BEFORE ANY PLASTERING IS APPLIED OR ANY JOINTS AND
FASTENERS HAVE BEEN TAPED AND FINISHED. INTERIOR DRYWALL SHALL BE 5/8"
MINIMUM AND SCREWED, NOT NAILED. INSTALL PER UBC REQUIREMENTS FOR
FASTENER SIZE, ETC.
48) CLOTHES DRYER SHALL BE EXHAUSTED TO THE OUTSIDE. CLOTHES DRYER
MOISTURE EXHAUST DUCT IS LIMITED TO 14 FEET WITH TWO ELBOWS FROM THE
CLOTHES DRYER TO POINT OF TERMINATION. REDUCE THIS LENGTH BY 2' FOR EVERY
ELBOW IN EXCESS OF TWO.
49) MINERAL FIBER INSULATION WILL BE INSTALLED IN JOIST SPACES WHENEVER A
PLUMBING PIPE OR DUCT PENETRATES A FLOOR-CEILING ASSEMBLY OR WHERE SUCH
UNIT PASSES THROUGH THE PLANE OF THE FLOOR-CEILING ASSEMBLY FROM WITHIN
A WALL. THE INSULATION SHALL BE INSTALLED TO A POINT OF 12" BEYOND THE PIPE
OR DUCT.
N/A 50) THE GARAGE SHALL BE MECHANICALLY VENTILATED IN ACCORDANCE WITH
SECTION 705, UBC AND AS DIRECTED. (SEE MECHANICAL PLANS)
51) ALL INTERIOR FINISH MATERIALS SHALL MEET CLASS III FLAME SPREAD
CLASSIFICATION.
52) ALL NEW WORK SHALL CONFORM WITH THE MINIMUM STANDARDS OF THE
GOVERNMENTAL AUTHORITIES HAVING JURISDICTION OVER THIS PROJECT AND THE
LATEST EDITION OF THE UNIFORM BUILDING CODE.
53) PROVIDE ONE HOUR FIRE RESISTANT PROTECTION UNDER STAIRS AND WALLS
WHEN AREA UNDER STAIRS IS ENCLOSED, AT PARTY WALLS, AND ALL WALL/FLOOR
ASSEMBLIES COMMON TO GARAGE AREA. PROVIDE 5/8" TYPE "X" GYPSUM BOARD
THROUGHOUT.
N/A 54) PROVIDE A 22"X30" (MINIMUM) ATTIC ACCESS DOOR WITH A MINIMUM 30"
CLEAR HEADROOM ABOVE OPENING. (U.N.O.)
55) PROVIDE 24 GAUGE GALVANIZED IRON (CORROSION RESISTANT) WEEP SCREED AT
MUDSILLS FOR ALL EXTERIOR STUCCO WALLS.
56) PROVIDE A 24" WIDE X 18" HIGH CRAWL-HOLE OR DOOR TO UNDERFLOOR AREA,
NOT MORE THAN 20 FEET FROM PLUMBING CLEANOUTS OR FORCED AIR UNIT. PIPES,
DUCTS AND OTHER NON-STRUCTURAL CONSTRUCTION COMPONENTS SHALL NOT
INTERFERE WITH ACCESSIBILITY.
57) PRIOR TO INSTALLATION OF ANY STAIRS, THE CONTRACTOR SHALL VERIFY THE
RISE, RUN, HEADROOM AND NUMBER OF TREADS AND RISERS, AND SHALL NOTIFY THE
DESIGNER OF ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS.
58) BELOW GRADE WATERPROOFING AT BLOCK WALLS, FOOTINGS AND AS
REQUIRED SHALL BE "THOROSEAL" OR "PARASEAL" SYSTEMS AND INSTALLED PER
MANUFACTURER'S SPECIFICATIONS. INSTALLATIONS SHALL BE STRICTLY ADHERED
TO.
59) 1 ½" LIGHT WEIGHT CONCRETE OVER 15# FELT OVER PLYWOOD SUBFLOOR.
60) APPROVED SPARK ARRESTOR FOR CHIMNEYS, STOVE, BBQ AND OTHER
APPLIANCES USING FUEL SHALL BE INSTALLED.
61) CONSTRUCTION, SCAFFOLDING, DEMOLITION ETC. EXCEEDING 3 STORIES IN
HEIGHT OR 36 FEET IN HEIGHT SHALL REQUIRE A PERMIT FROM THE DIVISION OF
INDUSTRIAL SAFETY PRIOR TO OBTAINING THE BUILDING PERMIT.
61) ALL SUBFLOOR VENTING SHALL BE WRAPPED WITH "JIFFY SEAL" AS IF IT WERE A
WINDOW INSTALLATION.
MECHANICAL, SHEET METAL
1) ALL SHEET METAL WORK SHALL BE IN ACCORDANCE WITH SMACNA MANUAL
STANDARDS AND ALL LOCAL CODES.
2) CONTRACTOR SHALL PROVIDE GAS-FIRED FURNACE(S) AND/OR FORCED AIR
HEATING SYSTEM AS INDICATED ON PLANS. FURNACES, DUCTS AND REGISTERS
SHALL BE SIZED AND INSTALLED TO PROVIDE ADEQUATE AIR, TEMPERATURE,
VOLUME, DISTRIBUTION AND CIRCULATION AT MINIMUM NOISE LEVELS. SYSTEM
EQUIPMENT AND LAYOUT SHALL BE CONFIRMED WITH OWNER AND DESIGNER PRIOR
TO ORDERING AND INSTALLATION.
3) DUCT WORK CONSTRUCTION: ALL DUCT WORK AND PLENUM TO BE MADE OF
GALVANIZED SHEET METAL IN ACCORDANCE WITH THE LATEST SMACNA STANDARDS
AND APPLICABLE CODES. CONTRACTOR SHALL SIZE DUCT WORK FOR S.P. NOT TO
EXCEED 0.1" PER 100' LENGTH FOR A GIVEN CFM. DUCTS MAY BE RECTANGULAR OR
ROUND.
4) DUCT INSULATION: INSULATE ALL SUPPLY AND RETURN AIR DUCT WORK AND
PLENUM WITH MINIMUM 2" THICK FIBERGLASS INSULATION WRAPPED AROUND WITH 2"
OVERLAP AND WIRED ON WITH #18 GALVANIZED WIRE @ 12" O.C.
5) PROVIDE GALVANIC OR BITUMINOUS INSULATION AS APPROVED BY DESIGNER
BETWEEN DISSIMILAR METALS.
STATE & ADMINISTRATIVE REQUIREMENTS
A. AT THE TIME OF PERMIT ISSUANCE, CONTRACTOR SHALL SHOW THEIR VALID
WORKERS' COMPENSATION INSURANCE CERTIFICATE.
B. ALL WORK SHALL CONFORM TO ALL REQUIREMENTS OF STATE OF CALIFORNIA
TITLE 24 REGARDLESS OF THE INFORMATION INDICATED ON THESE PLANS. IT IS
THE RESPONSIBILITY OF THE INDIVIDUAL SUPERVISING THE CONSTRUCTION TO
ENSURE THAT THE WORK IS DONE IN ACCORDANCE WITH CODE REQUIREMENTS
PRIOR TO REQUESTING INSPECTION.
C. EXCESS OR WASTE CONCRETE MAY NOT BE WASHED INTO THE PUBLIC WAY OR
ANY OTHER DRAINAGE SYSTEM. PROVISIONS SHALL BE MADE TO RETAIN
CONCRETE WASTES ON SITE UNTIL THEY CAN BE DISPOSED OF AS SOLID WASTE.
D. THE ISSUANCE OF A PERMIT SHALL NOT PREVENT THE BUILDING OFFICIAL FROM
REQUIRING THE CORRECTION OF ERRORS ON THESE PLANS OR FROM
PREVENTING ANY VIOLATION OF THE CODES ADOPTED BY THE CITY, RELEVANT
LAWS, ORDINANCES, RULES AND/OR REGULATIONS
E. SEPARATE PERMIT SHALL FIRST BE OBTAINED FROM THE CITY PUBLIC WORKS
DEPARTMENT PRIOR TO PLACEMENT OF ANY CONSTRUCTION MATERIALS OR
EQUIPMENT IN THE PUBLIC RIGHT OF WAY.
F. SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) SHALL BE NOTIFIED
IN ACCORDANCE WITH CALIFORNIA STATE LAW PRIOR TO START OF ANY
DEMOLITION, ADDITION, AND/OR REMODEL WORK. THE SOUTH COAST AIR QUALITY
MANAGEMENT DISTRICT OFFICE IS LOCATED AT 21865 COPLEY DRIVE IN DIAMOND
BAR, PHONE NO. (909) 396-2000. BE ADVISED,SCAQMD MAY REQUIRE A 10-DAY WAIT
PERIOD PRIOR TO START OF WORK.
G. SEDIMENTS AND OTHER MATERIALS MAY NOT BE TRACKED FROM THE SITE BY
VEHICLE TRAFFIC. THE CONSTRUCTION ENTRANCE ROADWAYS MUST BE
STABILIZED TO INHIBIT SEDIMENTS FROM BEING DEPOSITED INTO THE PUBLIC WAY.
ACCIDENTAL DEPOSITIONS MUST BE SWEPT UP IMMEDIATELY AND MAY NOT BE
WASHED DOWN BY RAIN OR OTHER MEANS.
H. STOCKPILES OF EARTH AND OTHER CONSTRUCTION RELATED MATERIALS MUST BE
PROTECTED FROM BEING TRANSPORTED FROM THE SITE BY THE FORCES OF WIND
OR WATER.
I. TRASH AND CONSTRUCTION RELATED SOLID WASTES MUST BE DEPOSITED INTO A
COVERED RECEPTACLE TO PREVENT CONTAMINATION OF RAINWATER AND
DISPERSAL BY WIND.
J. FUELS, OILS, SOLVENTS, AND OTHER TOXIC MATERIALS MUST BE STORED IN
ACCORDANCE WITH THEIR LISTING AND ARE NOT TO CONTAMINATE THE SOIL AND
SURFACE WATERS. ALL APPROVED STORAGE CONTAINERS ARE TO BE PROTECTED
FROM THE WEATHER. SPILLS MUST BE CLEANED UP IMMEDIATELY AND DISPOSED
OF IN A PROPER MANNER. SPILLS MAY NOT BE WASHED INTO THE DRAINAGE
SYSTEM.
K. THE PROJECT SITE SHALL BE KEPT CONTINUOUSLY FENCED IN ACCORDANCE UNTIL
THE PROJECT IS FINALED OR APPROVAL TO REMOVE THE FENCE HAS BEEN
OBTAINED FROM THE CITY BUILDING DIVISION. 24 HOUR SECURITY SHALL BE
PROVIDED ANY TIME THE FENCE CANNOT BE MAINTAINED INTACT. THIS APPLIES
IFTHE DWELLING IS GOING TO BE VACANT DURING CONSTRUCTION.
L. DUE TO THE POSSIBLE PRESENCE OF LEAD-BASED PAINT, LEAD-SAFE WORK
PRACTICES ARE REQUIRED FOR ALL REPAIRS THAT DISTURB THE PAINT IN
PRE-1979 BUILDINGS. FAILURE TO DO SO COULD CREATE LEAD HAZARDS THAT
VIOLATE CALIFORNIA HEALTH & SAFETY CODE, SECTIONS 17920.10 AND 105256 WITH
POTENTIAL FINES FOR VIOLATIONS UP TO$5,000 (SECTION (d) AMENDED) OR
IMPRISONMENT FOR NOT MORE THAN 6 MONTHS IN THE COUNTY JAIL OR BOTH.
M. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS
PROHIBITED. NO SOLID WASTE, PETROLEUM BY-PRODUCTS, SOIL PARTICULATE,
CONSTRUCTION WASTE MATERIALS, OR WASTEWATER GENERATED ON
CONSTRUCTION SITES OR BY CONSTRUCTION ACTIVITIES SHALL BE PLACED,
CONVEYED OR DISCHARGED INTO THE STREET, GUTTER OR STORM DRAIN
SYSTEM.
ISSUED
DATE:
REVISIONS
DRAWINGS, SPECIFICATIONS AND OTHER VISUAL AIDS, AS
INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE
DRAFTER/DESIGNER WHETHER THE PROJECT FOR
WHICH THEY ARE MADE BE EXECUTED OR NOT, AND
THEY ARE NOT TO BE USED FOR ANY OTHER SITE THAN
THE ONE FOR WHICH THEY ARE PREPARED, EXCEPT BY
AGREEMENT IN WRITING.
NO
.
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
DRAFTER/DESIGNER:
LUIS N OROZCO
562.661.9281
LUIS.OROZCO.A@LIVE.COM
DATE:
G103
GENERAL NOTES
PR
O
P
E
R
T
Y
O
W
N
E
R
:
S
I
L
V
I
A
T
O
R
R
E
S
15
1
1
S
.
B
I
R
C
H
S
T
.
SA
N
T
A
A
N
A
,
C
A
9
0
7
2
7
GA
R
A
G
E
C
O
N
V
E
R
S
I
O
N
T
O
A
N
AC
C
E
S
S
O
R
Y
D
W
E
L
L
I
N
G
U
N
I
T
09/10/2024
FINISH HARDWARE SHALL BE SELECTED BY THE DESIGNER. CONTRACTOR SHALL
PROVIDE SOLID BLOCKING AT ALL TOWEL BARS, TOILET PAPER HOLDERS, ETC.
CONTRACTOR SHALL PROVIDE AN ALLOWANCE FOR ALL HARDWARE FOR BIDDING
PURPOSES (U.N.O.).
EXTERIOR FINISH MATERIALS SHALL BE APPLIED OVER REQUIRED APPROVED
WATERPROOFING AS SPECIFIED BELOW.
PAINTED WOOD SURFACES SHALL BE SEALED, SANDED, SHOP PRIMED (U.N.O.) TO
RECEIVE FINISH PAINT COAT.
INTERIOR TRIM AND MILLWORK SHALL BE FURNISHED AND PROPERLY INSTALLED AS
SPECIFIED AND DETAILED ON THE PLANS. RUBBERIZED MOULDINGS SHALL BE SPECIAL
ORDERED WHEN REQUIRED FOR RADUIS AND/OR CURVED SURFACES AND ELEMENTS.
FLASHING
ALL PLUMBING PIPES SHALL BE FULLY INSULATED
FLASHING MATERIAL SHALL BE MINIMUM 26 GAUGE GALVANIZED STEEL.
FLASH AND COUNTER FLASH ALL ROOF TO WALL CONDITIONS. FLASH AND CAULK ALL
VERTICAL TO HORIZONTAL JOINTS AND PLANE VARIATIATIONS. WOOD BEAMS,
CORBELS, OUTLOOKERS, PROJECTIING THROUGH EXTERIOR WALLS, FLOORS, ROOF
SURFACES AND/OR BALCONY, VERTICLE PIPES ETC. SHALL BE FLASHED AND
CAULKED.
GALVANIZED FLASHING SHALL BE CLEARED OF ALL FLUX AND SHOP PAINTED AS
SPECIFIED UNDER PAINTING.
EXTERIOR OPENINGS SHALL BE PROPERLY FLASHED WITH APPROVED WATER
PROOFING MATERIALS.
JOINTS AROUND DOORS, WINDOWS, MUDSILLS, WEEP SCREEDS, TRIM
INTERSECTIONS AND ALL EXTERIOR OPENINGS SHALL BE COMPLETELY SEALED WITH
THE HIGHEST GRADE OF NON-HARDENING, NON-STAINING ELASTIC COMPOUND
CAULKING AFTER INSTALLATION OF SURROUNDING WORK IN A QUICK AND TIMELY
MANNER (AS SOON AS POSSIBLE).
EXTERIOR CEMENT PLASTER SHALL BE UNDERLAIN WITH A MINIMUM OF TWO LAYERS
GRADE D PAPER AND MESH GALVANIZED SELF-FURRING METAL LATH 1.75 #/CU.FT. OR
EQUIVALENT WITH 15# SATURATED BUILDING FELT AT PLYW OOD.
WEEP SCREEDS SHALL BE INSTALLED AT THE FOUNDATION SILL LINE ON ALL
EXTERIOR WALLS AND AS SHOWN ON DRAWINGS. WEEP SCREED SHALL HAVE A DRIP
LINE FOR DRAINING TRAPPED WATER TO THE EXTERIOR OF THE BUILDING.
FLASHIING, CORNER BEADS, SCREEDS, ETC., SHALL BE INSTALLED PROPERLY AS
APPROPRIATE TO CONDITION AND AS SPECIFIED
THERMAL AND MOISTURE PROTECTION
ALL WORK SHALL COMPLY WITH TITLE 24 REQUIREMENTS
INSULATION SHALL BE FIBERGLASS BATTS WITH KRAFT PAPER BACKING AND SHALL
CONFORM TO FEDERAL SPECIFICATIONS.
MINERAL FIBER INSULATION SHALL BE INSTALLED IN JOIST SPACES WHENEVER A
PLUMBING PIPE OR DUCT PENETRATES A FLOOR-CEILING ASSEMBLY AND/OR WHEN
THEY PASS THROUGH THE PLANE OF THE FLOOR-CEILING ASSEMBLY FROM A WALL.
INSULATION SHALL EXTEND 12" PAST THE DUCTING AND/OR THE PIPING.
THE CERTIFICATE OF COMPLIANCE SHALL BE SIGNED BY THE INSULATING SUB-
CONTRACTOR AND GENERAL CONTRACTOR AND SHALL BE PROMINATELY POSTED ON
THE CONSTRUCTION SITE.
ALL INSULATION MATERIALS SHALL BE CERTIFIED BY THE MANUFACTURER AND
COMPLY WITH THE CALIFORNIA QUALITY STANDARDS FOR INSULATING MATERIALS.
R-3 INSULATION OR GREATER SHALL BE INSTALLED ON WATER INLET AND OUTLET
PIPES FOR THE FIRST 5 FEET OF UNCONDITIONED SPACE U.N.O. (SEE TITLE 24
CALCULATIONS)
FINISH CARPENTRY
WOOD TRIM SHALL BE IN SINGLE LENGTHS WHEN POSSIBLE
MITER INTERIOR TRIM AT JOINTS
KERF OR BACK CUT FLAT TRIM MEMBERS AS REQUIRED TO PREVENT WARPING.
SET NAIL HEADS TO RECEIVE PUTTY.
BASE MOULD SHALL MATCH EXISTING HOUSE
DOOR AND WINDOW CASINGS AND DRYWALL BULLNOSE FINISH SHALL MATCH
EXISTING OR BE PER SPECS.
DOORS SHALL BE HUNG IN TRUE VERTICAL PLANE WITHOUT WARP OR WIND AND BE
FITTED SO AS TO HAVE 1/16" CLEARANCE ABOVE THRESHOLDS WHERE DOORS OPEN
INTO ROOMS. OTHERWISE, CLEARANCE SHALL BE 3/8" ABOVE THE FLOORS FOR
INTERIOR DOORS. THE CLEARANCE AT THE HEAD AND JAMB SHALL BE 3/32". EXTERIOR
DOORS SHALL BE FULLY WEATHERSTRIPPED.
DOORKNOBS SHALL BE 36" ABOVE THE FINISHED FLOOR. LOCATION OF DOOR PULLS
AND DEAD BOLTS SHALL BE LOCATED BY OWNERS. HANDICAPPED REQUIREMENTS
SHALL APPLY AS REQUIRED IN HANDICAPPED SPACES AS REQUIRED BY ADA
STANDARDS.
PAINT
PAINTER SHALL FURNISH MATERIALS, EQUIPMENT AND PERFORM ALL LABOR
REQUIRED TO COMPLETE "PAINTING" WORK IN THE BEST METHOD AND STANDARDS
OF THE TRADE - ALL INTERIOR AND EXTERIOR SURFACES, EXCLUDING THOSE ITEMS
OR AREAS WITH FACTORY APPLIED FINISHES OR AS DIRECTED.
THE CONTRACTOR SHALL INSURE EVEN APPLICATION PROPER CONSISTENCY DURING
FAVORABLE WEATHER CONDITIONS.
PROPER CLEANING AND SURFACE PREPARATION SHALL PRECEDE APPLICATION OF
PRIMER COAT PLUS TWO FINISH COATS. PRIMER SHALL BE COLORED TO MATCH
FINISH COLOR.
WITH THE EXCEPTION OF TRIM AND TOUCH-UP WORK, PAINT SHALL BE BATCHED IN 5
GALLON CONTAINERS PRIOR TO APPLICATION.
ALL UNPAINTED SURFACES SHALL BE ADEQUATELY PROTECTED FROM PAINT OR
DAMAGE.
CONTRACTOR SHALL PROVIDE (6) SIX DIFFERENT INTERIOR COLORS THROUGHOUT
THE ENTIRE PROJECT NEW AND OR EXISTING. PAINT AND/OR STAIN COLORS SHALL BE
SPECIFIED BY DESIGNER.
CONTRACTORS SHALL PROVIDE (2) TWO DIFFERENT EXTERIOR COLORS AT THE
EXTERIOR, NEW AND EXISTING. PAINT AND STAIN COLORS SHALL BE SPECIFIED BY
DESIGNER.
CONTRACTORS SHALL PROVIDE OWNERS WITH (3) THREE COLOR SAMPLES OF EACH
COLOR, APPROXIMATELY 3'-0" X 3'-0" COLOR SAMPLE, PRIOR TO WORK BEING
PERFORMED.
GRADING NOTES
ALL FOOTINGS SHALL BE FOUNDED IN UNDISTURBED NATURAL SOIL PER CODE.
IN THE EVENT EXCAVATIONS REVEAL UNFAVORABLE CONDITIONS, THE SERVICES OF A
SOILS ENGINEER AND/OR GEOLOGIST MAY BE REQUIRED. CONTACT THE DESIGNER
IMMEDIATELY.
ALL CONCENTRATED DRAINAGE, INCLUDING ROOF WATER, SHALL BE CONDUCTED, VIA
GRAVITTY TO THE STREET OR AN APPROVED LOCATION AT A 2% MINIMUM.
ALL FILL OR BACKFILL SHALL BE COMPACTED BY MECHANICAL MEANS TO A MINIMUM
90% RELATIVE COMPACTION AS DETERMINED BY ASTM METHOD D-1557. SUBDRAINS
SHALL BE PROVIDED WHERE REQUIRED BY CODE.
MISCELLANEOUS DOOR & WINDOW NOTES
1. ALL GLASS WITHIN 18" OF THE FINISHED FLOOR SHALL BE FULL TEMPERED.
TEMPERED GLASS REQ'S PERMANENT ETCHED LABEL EXC. SPANDREL GLASS
REMOVABLE PAPER LABEL OK PER SECTION 2406.2 UBC 2001.
2. ALL EGRESS OR RESCUE WINDOWS FROM SLEEPING ROOMS SHALL BE PROVIDED
WITH A MINIMUM CLEAR OPENING OF 5.7 SQUARE FEET WITH THE MINIMUM NET
WIDTH DIMENSION OF THE OPENING NOT LESS THAN 20". WHERE WINDOWS ARE
PROVIDED AS A MEANS OF EGRESS OR RESCUE. THEY SHALL HAVE A FINISHED
SILL HEIGHT OF NOT MORE THAN 44' ABOVE THE ADJACENT FINISHED FLOOR.
3. ALL EXTERIOR DOORS AND WINDOWS SHALL COMPLY WITH THE BUILDING CODE
SECURITY REQUIREMENTS AS ADOPTED BY THE LOCAL BUILDING DEPARTMENT
AND SPECIFIED ELSEWHERE ON THIS SHEET.
4. FRENCH DOORS AND WINDOWS USED AS A MEANS TO PROVIDE MINIMUM
VENTILATION REQUIREMENTS SHALL BE OPEN-ABLE AND SHALL BE PROVIDED
WITH SCREENS UNLESS NOTED OTHERWISE ON THE PLANS AND SPECIFICATIONS.
ALL SUCH DOORS AND WINDOWS SHALL BE EQUIPPED WITH A MECHANICAL HOLD
OPEN DEVICE.
5. CONTRACTOR SHALL VERIFY EXACT ROUGH OPENING HEIGHT AND WIDTH OF ALL
DOORS AND WINDOWS WITH DOOR AND WINDOW MANUFACTURER PRIOR TO
START OF ROUGH FRAMING. ROUGH FRAMING SUB-CONTRACTOR IS
RESPONSIBLE FOR PROVIDING ALL FRAMING NAILERS AND FILLERS AS SHOWN ON
WINDOW AND DOOR DETAILS, MANUFACTURE'S STANDARD DETAILS AND AS MAY
OTHERWISE BE REQUIRED FOR THE PROPER INSTALLATION OF ALL DOORS AND
WINDOWS.
6. ALL PANEL TYPE DOORS SHALL BE UNITS MANUFACTURED BY T.M. COBB CO.
PANEL TYPE DOORS SHALL BE F-66 TYPE UNLESS NOTED OTHERWISE ON PLANS.
7. ALL WINDOWS ARE BASED ON MILGARD ALUMINUM SERIES. FRENCH WINDOWS
SHALL BE PROVIDED WITH FULLY TEMPERED GLASS. WINDOW UNITS SHALL BE
PROVIDED WITH CLEAR DBL. GLAZING UNLESS NOTED OTHERWISE ON PLANS.
PROVIDE FULLY TEMPERED GLASS AT CERTAIN WINDOWS AS SPECIFIED ON
WINDOW SCHEDULE.
8. WINDOW UNITS SHALL BE FULLY ASSEMBLED UNITS CONSTRUCTED PER
SPECIFICATIONS
9. WINDOW UNITS SHALL BE HINGED AS INDICATED ON EXTERIOR ELEVATIONS
AND/OR PLANS.
10. WINDOW UNITS SHALL BE DELIVERED TO THE JOB SITE WITH ALL HARDWARE
SUCH AS OPERATORS, CRANK, OPERATOR ARM, LOCK, ETC.
11. OWNER SHALL PROVIDE ALL NECESSARY HARDWARE NOT INCLUDED IN
MANUFACTURED UNIT CONTRACTOR TO INSTALL ALL HARDWARE.
12. ALL DOOR HARDWARE SHALL BE PROVIDED BY OWNER AND INSTALLED BY
CONTRACTOR.
13. ALL DOOR UNITS AND THEIR RESPECTIVE FRAMES SHALL BE PAINT GRADE.
14. SAMPLE WINDOW TO BE APPROVED WITH SIGNED SHOP DRAWINGS BY OWNER/
DESIGNER.
15. UNLESS NOTED OTHERWISE, ALL EXTERIOR SWING DOORS TO BE SUPPLIED WITH
MILL FINISHED EXTRUDED BRONZE PEMPO THRESHOLDS 114 B OR 145 B/ WITH 16
oz. COPPER DRAIN PAN. THRESHOLDS TO BE POLISHED TO REMOVE MILL
MARKINGS. PEMKO SPRING BRONZE WEATHER STRIPPING @ HEAD AND JAMBS.
16. CAULK ALL INTERIOR/ EXTERIOR PLASTER JOINTS.
17. ALL GLAZING ON DOORS AND WINDOWS TO BE DBL GLAZE 'LOW E' INSULATED
GLASS.
SECURITY NOTES (WHERE APPLICABLE):
1. ALL EXTERIOR DOOR AND WINDOW OPENINGS ARE SECURITY OPENINGS, AND ALL
NOTES SHALL APPLY.
2. WOOD FLUSH-TYPE DOORS SHALL BE 1 3/4" THICK MINIMUM AND SHALL BE OF
SOLID CORE CONSTRUCTION.
3. HOLLOW CORE DOORS OR DOORS LESS THAN 1 3/4" IN THICKNESS SHALL BE
COVERED ON THE INSIDE FACE WITH 16 OZ SHEET METAL ATTACHED WITH
SCREWS AT 6" O/C AROUND THE PERIMETER, OR EQUIVALENT.
4. GLAZED OPENINGS WITHIN 4" OF THE DOOR LOCK, WHEN THE DOOR IS IN THE
CLOSED POSITION. SHALL BE FULLY TEMPERED GLASS OR APPROVED BURGLARY
RESISTANT MATERIAL, OR SHALL BE PROTECTED BY METAL BARS, SCREENS OR
GRILLES HAVING A MAXIMUM OPENING OF 2". THE PROVISIONS OF THIS SECTION
SHALL NOT APPLY TO VIEW PORTS OR WINDOWS, WHICH DO NOT EXCEED 2" IN
THEIR GREATEST DIMENSION.
5. GLASS DOORS SHALL HAVE FULLY TEMPERED GLASS . TEMPERED GLASS REQ'S
PERMANENT ETCHED LABEL EXC. SPANDREL GLASS REMOVABLE PAPER LABEL
OK PER SECTION 2406.2 UBC 2001.
6. DOORSTOPS OF IN-SWINGING DOORS SHALL BE OF ONE-PIECE CONSTRUCTION
WITH THE JAMB, OR JOINED BY RABBET TO THE JAMB.
7. ALL PIN-TYPE HINGES WHICH ARE ACCESSIBLE FROM OUTSIDE THE SECURED
AREA WHEN THE DOOR IS CLOSED SHALL HAVE NON-REMOVABLE HINGE PINS. IN
ADDITION THEY SHALL HAVE MINIMUM ¼" DIAMETER STEEL JAMB STUD WITH ¼"
MINIMUM PROJECTION UNLESS THE HINGES ARE SHAPED TO PREVENT REMOVAL
OF THE DOOR IF THE HINGE PINS ARE REMOVED.
8. THE STRIKE PLATE FOR LATCHES AND THE HOLDING DEVICE FOR PROJECTION
DEAD BOLTS IN WOOD CONSTRUCTION SHALL BE SECURED TO THE JAMB AND
THE WALL FRAMING WITH SCREWS NOT LESS THAN 2 1/1" IN LENGTH.
9. DEAD BOLTS SHALL HAVE HARDENED INSERTS; PROVIDE DEADLOCKING LATCH
KEY OPERATED LOCKS ON THE EXTERIOR; LOCKS SHALL BE OPENABLE WITH OUT
KEY, SPECIAL KNOWLEDGE OR SPECIAL EFFORT FROM THE INTERIOR.
10. STRAIGHT DEAD BOLTS SHALL HAVE A MINIMUM THROW OF 1" AND AN
EMBEDMENT OF NOT LESS THAN 5/8".
11. A HOOK SHAPED OR AN EXPANDING-LUG DEAD BOLT SHALL HAVE A MINIMUM
THROW OF 3/4".
12. CYLINDER GUARDS SHALL BE INSTALLED ON ALL CYLINDERS LOCKS WHENEVER
THE CYLINDER PROJECTS BEYOND THE FACE OF THE DOOR OR IS OTHERWISE
ACCESSIBLE TO GRIPPING TOOLS.
13. SLIDING GLASS DOORS AND WINDOWS SHALL BE EQUIPPED WITH LOCKING
DEVICES AND SHALL BE SO CONSTRUCTED AND INSTALLED THAT THEY REMAIN
INTACT AND ENGAGED WHEN SUBJECTED TO THE TESTS SPECIFIED IN SECTIONS
91.6731 AND 91.6732.
14. SLIDING GLASS DOORS AND WINDOWS SHALL BE PROVIDED WITH A DEVICE IN
THE UPPER CHANNEL OF THE MOVING PANEL TO PROHIBIT RAISING AND
REMOVING OF THE MOVING PANEL IN THE CLOSED OR PARTIALLY OPEN POSITION.
15. SCREENS, BARRICADES, OR FENCES MADE OF MATERIAL WHICH PRECLUDES
HUMAN CLIMBING SHALL BE PROVIDED AT EVERY PORTION OF EVERY ROOF,
BALCONY, OR SIMILAR SURFACE WHICH IS WITHIN 8' OF A UTILITY POLE OR
SIMILAR STRUCTURE.
16. PROVIDE SAFETY GLAZING IN THE FOLLOWING LOCATIONS PER CODE. TEMPERED
GLASS REQ'S PERMANENT ETCHED LABEL EXC. SPANDREL GLASS REMOVABLE
PAPER LABEL OK PER CODE
SLIDING OR SWINGING DOORS
1. TUB AND/OR SHOWER ENCLOSURES AND GLAZING IN WALLS LESS THAN 60"
ABOVE THE STANDING SURFACE OF TUBS OR SHOWERS.
2. GLAZING WITHIN A 24" ARC OF A DOOR.
CONCRETE
NOTE: STRUCTURAL AND GEOLOGICAL NOTES AND DRAWING SHALL SUPERSEDE THE
FOLLOWING
WATER FOR CONCRETE MIXING SHALL BE FRESH, CLEAN AND SUITABLE FOR
DOMESTIC PURPOSES.
ALL EMBEDDED HARDWARE SHALL BE ICBO APPROVED. REINFORCEMENT, BOLTS,
ANCHORS, SLEEVES, HOLD DOWNS ETC. SHALL BE FREE OF DIRT AND RUST PRIOR TO
POURING OF CONCRETE.
ALL SHOT PINS, REDHEADS AND MISCELLANEOUS HARDWARE SHALL BE ICBO
APPROVED
ALL WOOD SHALL BE A MINIMUM OF 6" ABOVE FINISHED GRADE
SILL PLATES SHALL BE INSTALLED WITH FULL BEARING ON FOOTING WALL OR MORTAR
BED. ALL WOOD CONTACTING CONCRETE SHALL BE PRESSURE TREATED.
ALL WORK SHALL BE PLUMB, SQUARE ACCORDING TO THE PLANS, U.N.O.
EXPOSED CONCRETE SURFACES SHALL HAVE A BROOM FINISH PROVIDING A NON-SLIP
SURFACE U.N.O..
ALL FOOTINGS SHALL SET ON FIRM NATURAL SOIL OR APPROVED COMPACTED FILL.
REFER TO SOILS REPORT. LOAD BEARING FOOTINGS SHALL EXTEND BELOW NATURAL
GRADE.
REMOVE ALL WATER FROM TRENCHES AND FOUNDATION PRIOR TO POURING THE
CONCRETE . FORMS SHALL BE WETTED.
CONCRETE SHALL BE PLACED AS QUICKLY AS POSSIBLE TO PREVENT SEPARATION
OF MATTER.
CONCRETE SLABS SHALL BE 3 1/2" MINIMUM (U.N.O.) OVER 4" COURSE AGGREGATE
BASE OR SAND BASE WITH MOISTURE BARRIER. PROVIDE "VISQUEEN" OR EQUIVALENT
VAPOR BARRIER BETWEEN SLAB AND BASE. (VERIFY WITH STRUCTURAL PLANS AND
NOTES )
CONTRACTOR WILL REPLACE AND/OR REPAIR EXISTING DRIVEWAY, PATIOS ,
WALKWAYS ETC. WHICH MAY BE DAMAGED DURING CONSTRUCTION.
MASONRY
STRUCTURAL NOTES AND DRAWING SHALL SUPERSEDE THE FOLLOWING:
MASONRY SHALL BE SET IN RUNNING BOND PATTERN U.N.O.
MASONRY SHALL MEET THE REQUIREMENTS FOR "HOLLOW LOAD BEARING CONCRETE
MASONRY UNITS", ASTM C-90 AND COMPLY WITH LATEST EDITION OF THE UNIFORM
BUILDING CODE.
MORTAR AND GROUT SHALL BE OF FLUID CONSISTENCY AND RETEMPERING IS NOT
ALLOWED.
WALLS SHALL BE TRUE AND PLUMB. ALL JOINTS SHALL BE FULL FLUSH, BROOM FINISH.
ALL CELLS CONTAINING REINFORCEMENT SHALL BE FILLED SOLID WITH GROUT. WHEN
TOTAL GROUT POUR EXCEED 8 FEET IN HEIGHT, THE GROUT SHALL BE PLACED IN 4
FOOT LIFTS AND SPECIAL INSPECTION SHALL BE PROVIDED AS REQUIRED.
ALL MASONRY WORK SHALL BE LEFT CLEAN, FREE FROM EXCESS CEMENT AND
EFFLORESCENCE AND IN A CONDITION SUITABLE FOR PAINTING, CEMENT PLASTER OR
NO FINISH.
METALS
STRUCTURAL NOTES AND DRAWING SHALL SUPERSEDE THE FOLLOWING:
CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR AND MATERIAL NECESSARY
TO MAKE ALL FLASHING, VALLEYS, CHIMNEYS, RIDGES, SADDLES, CONDUCTORS AND
ALL CONNECTIONS WATERTIGHT.
ALL GALVANIZED STEEL SHALL BE 24 GAUGE MINIMUM U.N.O.
ALL WORK SHALL BE SHOP PRE-FABRICATED WHEN POSSIBLE TO LIMIT SOLDERING
JOINTS WHEN INSTALLED.
ALL EXPOSED STEEL SHALL BE DOUBLE GALVANIZED.
PROVIDE AND SET ALL IRON AND STEEL BEAMS, PIPE COLUMNS, ANCHORS AND
MISCELLANEOUS ETC., AS SHOWN ON DRAWINGS.
PROVIDE AND INSTALL ALL FRAMING HARDWARE REQUIRED FOR POSTS, BEAMS,
RAFTERS, JOISTS AND OTHER FRAMING MEMBERS AS REQUIRED.
PROVIDE AND INSTALL ALL ROOF AND DECK DRAINS AND INTERIOR DOWNSPOUTS AS
MAY BE REQUIRED TO DRAIN ALL ROOF AND DECK WATER AND CONDUCT IT THROUGH
ENCLOSED PIPING AND TO THE STREET.
WOOD, PLASTIC & CARPENTRY
STRUCTURAL NOTES AND DRAWING SHALL SUPERSEDE THE FOLLOWING:
ALL WORK SHALL CONFORM TO GENERAL CONSTRUCTION REQUIREMENTS AND
CONSTRUCTION PROVISIONS OF THE LATEST EDITION UBC. ALL WORK PERFORMED
SHALL BE OF HIGH QUALITY WORKMANSHIP.
DOOR FRAMES SHALL BE A SUITABLE DEPTH TO RECEIVE WALL FINISHED AS SHOWN
ON DETAILS
GALVANIZED NAILS SHALL BE USED FOR ALL EXTERIOR WOOD
ALL FINISH WOOD, EXTERIOR AND INTERIOR SHALL BE NAILED WITH FINISH NAILS AND
COUNTERSUNK.
GLUE AND NAIL PLYWOOD SUB-FLOORING. (SEE STRUCTURAL PLANS AND DRAWINGS)
ALL BOLTS AND NUTS BEARING ON WOOD SHALL HAVE WASHERS. (SEE STRUCTURAL
PLANS AND DRAWINGS)
CROSS BRIDGE OR SOLID BLOCK FLOOR JOISTS EVERY 8 FEET MAX. AND SOLID BLOCK
AT SUPPORTS. BLOCK AT PLYWOOD SUB-FLOOR EDGES.
WOOD TRIM SHALL BE IN SINGLE LENGTHS WHEN POSSIBLE.
MITER INTERIOR TRIM AT JOINTS
KERF OR BACK CUT FLAT TRIM MEMBERS AS REQUIRED TO PREVENT WARPING
WORK SHALL BE INSTALLED AND SANDED AND NAIL HEADS SET TO RECEIVE PUTTY
READY FOR PAINTING OR STAINING.
WOOD CASINGS, BASE AND CROWN MOULDS, WINDOW STOOL AND APRONS, RUNNING
TRIM AND CABINETS SHALL BE AS DETAILED AND SPECIFIED.
QUARTER ROUND BASE SHOE AT WOOD FLOORS SHALL MATCH EXISTING
FRAMING SHALL BE PERFORMED IN A PROFESSIONAL MANNER BY SKILLED
CRAFTSPERSONS.
ALL WOODWORK, BLOCKING, GROUNDS, ROUGH BUCKS AND MISC. FIRE BLOCKING
SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS OR
ORDINANCES.
THE FRAMING SUB-CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND
FITTING OF WOOD MEMBERS AS REQUIRED BY PLUMBING, ELECTRICAL, HEATING AND
MECHANICAL CONTRACTORS.
ALL GROUNDS AND/OR NAILERS SHALL BE PROVIDED AND INSTALLED AS REQUIRED
FOR PLASTERING, DRYWALL WORK, WOOD BASES AND TRIMS AND SO FORTH AS
REQUIRED. FURR AND BLOCK AS REQUIRED FOR ARCHITECTURAL FEATURES.
FURNISH ALL ROUGH AND FINISH HARDWARE AS REQUIRED TO COMPLETE
CONSTRUCTION OF THE JOB WITH HIGH QUALITY CRAFTSMANSHIP.
FLOOR PLAN LEGEND
(E) DOOR
(E) WALL PARTITION
(N) 1 HR FIRE RATED WALL
(E) WALL TO BE REMOVED
(N) WALL
(E) DOOR TO
BE REMOVED
(N) DOOR
(E) WINDOW (E) WINDOW
TO BE
REMOVED
(N) WINDOW
WALL TYPES
2A -EXTERIOR WALL
(2) 5/8" TYPE X GYP. BD. SEE FINISH
SCHEDULE FOR FINISHES ON WALL.
REFERENCE INTERIOR ELEVATIONS
FOR LOCATION
(E) 7/8" EXT. PLASTER ON METAL LATH OVER
(2) LAYERS OF GRAD "D" BLDG. PAPER
1A -INTERIOR WALL
2" X 4" WOOD STUDS @ 16" O.C.
NOTE:
1. 1-HR FIRE RESISTANCE RATED WALL IN ACCORDANCE WITH CRC TABLE
R302.1, CBC SECTION 703.3 AND TABLE 722.2.1.4
2. BATT INSULATION PER T24 DRAWINGS.
2B -EXTERIOR WALL
2" X 4" WOOD STUDS @ 16" O.C.
W/ BATT INSULATION
1/2" EXT. PLYWOOD
7/8" EXT. PLASTER ON METAL LATH OVER
(2) LAYERS OF GRAD "D" BLDG. PAPER
FLOOR PLAN NOTES
1. DIMENSIONS NOTED IN PLAN ARE TAGGED TO EXTERIOR FACE OF STUD U.N.O.
2. ALL CONSTRUCTION SHALL BE DONE IN ACCORDANCE WITH CURRENT
BUILDING CODES, PROVIDED STRUCTURAL PLANS, CALCULATIONS, AND NOTED
REQUIREMENTS FOUND ON THE TITLE 24 DOCUMENTS.
3. GC TO PROVIDE / CONFIRM WALL INSULATION RATING MIN. OF R-15. WHERE
MIN. CRITERIA IS NOT MET & INSTALL / REPLACE INSULATION AS REQ. PER TITLE
24, TYP.
4. BASEMENT, HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALL HAVE AT
LEAST ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING HAVING A
MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET EXCEPT FOR GRADE FLOOR
OPENINGS WHICH SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 SQUARE
FEET. THE MIN. NET CLEAR OPENING HEIGHT SHALL BE 24 IN., WIDTH SHALL BE
20 IN. MIN. AND BOTTOM OF THE CLEAR OPENING SHALL BE NO GREATER THAN
44 INCHES MEASURED FROM THE FLOOR.
5. GC TO VERIFY EXISTING FOOTING SUPPORTING BEARING AND SHEAR WALLS
ABOVE MEET MIN. SIZE AND DEPTH REQS.
6. EXISTING FOOTING SHALL BE EXPOSED AT LEAST AT (2) LOCATIONS FOR CITY
INSPECTION TO MEET SIZE AND EMBEDMENT OF PAD/CONTINUOUS FOOTINGS
PER CITY WOOD FRAMING PRESCRIPTIVE PROVISIONS.
7. PLUMBING FIXTURES SHALL COMPLY WITH WATER CONSERVATION FLOW
RATES: SHOWERHEADS-1.8GPM, LAVATORY FAUCETS-1.2 GPM, KITCHEN
FAUCETS-1.8 GPM, WATER CLOSETS-1.28 GPM.
8. A MINIMUM OF 4" MOISTURE EXHAUST DUCT MUST BE PROVIDED FOR
CLOTHES DRYER. GC TO CONFIRM MANUFACTURER SPECIFICATIONS AND
INSTALL ACCORDINGLY.
A. A FLEXIBLE DUCT CANNOT EXTEND MORE THAN 6 FT. AND CANNOT BE
CONCEALED.
B. DRYER EXHAUST CANNOT EXCEED 14 FT. WITH A MAXIMUM OF TWO 90-
DEGREE ELBOWS PER CMC. 504.4.2
THE FOLLOWING IS A SUMMARY OF FEATURES THAT MUST BE FIELD-VERIFIED BY
A CERTIFIED HERS RATER:
BUILDING-LEVEL VERIFICATIONS:
• QUALITY INSULATION INSTALLATION (QII)
• INDOOR AIR QUALITY VENTILATION
• KITCHEN RANGE HOOD
• VERIFIED REFRIGERANT CHARGE
• VERIFIED HEAT PUMP RATED HEATING CAPACITY
SEE T24 SHEETS (FORM CF1R)FOR FURTHER INFO. & REQUIRED SPECIAL
FEATURES
CERTIFICATES OF INSTALLATION (CF2R-ENV, CF2R-LTG AND CF2R-MECH) SHALL
BE COMPLETED BY THE APPLICABLE CONTRACTORS INSTALLING ENERGY
FEATURES. WHEN COMPLIANCE REQUIRES HERS FIELD VERIFICATION AND/OR
TESTING, ALL CF2R FORMS SHALL BE SUBMITTED ELECTRONICALLY TO AN
APPROVED HERS PROVIDER DATA REGISTRY. THE CF2R FORMS SHALL BE
POSTED AT THE JOB SITE IN A CONSPICUOUS LOCATION.
CERTIFICATE OF VERIFICATION (CF3R) SHALL BE COMPLETED, REGISTERED, AND
SIGNED/CERTIFIED BY THE HERS RATER. THE REGISTERED CF3R FORM SHALL BE
MADE AVAILABLE TO THE BUILDING DEPARTMENT AND BUILDER.
HERS FEATURES SUMMARY:
NOTE:
1 HR RATED WALL
WHERE NOTED
TITLE-24 ENERGY REQUIREMENTS
1. ALL OF THE LUMINARIES IN A KITCHEN MUST BE HIGH EFFICACY.
2. BATHROOMS, GARAGES, LAUNDRY OR UTILITY ROOMS MUST HAVE HIGH
EFFICACY LIGHTING, AND AT LEAST ONE LUMINAIRE IN EACH OF THESE SPACES
MUST BE CONTROLLED BY A VACANCY SENSOR.
3. BEDROOMS, LIVING ROOMS, FAMILY ROOMS, AND OTHER ROOMS USED FOR
LIVING AND SLEEPING MUST HAVE HIGH EFFICACY LIGHTING, OR AN OCCUPANT
SENSOR, OR DIMMERS MAY BE INSTALLED.
4. EXTERIOR LIGHTING MUST BE HIGH EFFICACY, OR AN OCCUPANT SENSOR
WITH AN INTEGRAL PHOTO CONTROL MAY BE INSTALLED.
2" X 4" WOOD STUDS @ 16" O.C.
W/ BATT INSULATION
1B -INTERIOR WALL 5/8" GYP BOARD. FINISH PAINT
TBD.
2" X 6" WOOD STUDS @ 16" O.C.
5/8" CEMENTITIOUS BD OR 5/8" GYP. BD.
SEE FINISH SCHEDULE FOR FINISHES
ON WALL. REFERENCE INTERIOR
ELEVATIONS FOR LOCATION
NOTE:
UTILIZE ALUMINUM "J" MOLDING AT
TRANSITIONS BETWEEN TILE AND
GYP. BD.
5/8" GYP BOARD. FINISH PAINT TBD.
1C -INTERIOR WALL 5/8" TYPE-X GYP BOARD. FINISH
PAINT TBD.
2" X 6" WOOD STUDS @ 16" O.C.
W/ BATT INSULATION
5/8" GYP. BD. SEE FINISH SCHEDULE
FOR FINISHES ON WALL. REFERENCE
INTERIOR ELEVATIONS FOR LOCATION
NOTE:
UTILIZE ALUMINUM "J" MOLDING AT
TRANSITIONS BETWEEN TILE AND
GYP. BD.
5/8" GYP. BD OR 5/8" TYPE X GYP. BD.
SEE FINISH SCHEDULE FOR FINISHES
ON WALL. REFERENCE INTERIOR
ELEVATIONS FOR LOCATION
UNIT COMPLIANCE CALCULATIONS
NATURAL LIGHTING CALC.NATURAL VENTILATION CALC.
NATURAL LIGHT CALCULATIONS PER 2022 CRC R303
KITCHEN / LIVING ROOM = 268 SF
268 X (8%) = 21.44 SF -MIN. LIGHT REQ.
PROVIDED LIGHT AREA:
1 (36"X36") WINDOW = 9 SF
1 (48"X48") WINDOW = 16 SF
25 SF > 21.44 SF = COMPLIANT
NATURAL VENTILATION CALCULATIONS PER 2022 CRC R303
KITCHEN/ LIVING ROOM = 268 SF
268 X (4%) = 10.72 SF -MIN. VENT. REQ.
PROVIDED VENTILATION AREA:
1 (36"X36") WINDOW = 9 SF
= 50% OPERABLE (9) X (50%) = 4.5 SF
1 (48"X48") WINDOW = 16 SF
= 50% OPERABLE (16) X (50%) = 8 SF
11 SF > 10.72 SF = COMPLIANT
DEMO (NON-BEARING)
INT. WALL
GC TO REMOVE / REPAIR /
REPLACE INTERIOR WALL AND
FLOOR FINISHES AS REQUIRED.
INTERIOR PAINT TBD.
DEMO
DOOR
DEMO
EXT. WALL
DEMO
DOOR
DEMO
DOOR
20
'
-
2
"
O
V
E
R
A
L
L
(
V
.
I
.
F
.
)
18'-6" OVERALL (V.I.F.)
(E
)
C
L
O
S
E
T
18
'
-
7
"
O
V
E
R
A
L
L
(
V
.
I
.
F
.
)
2'-2"
14'-2 1/2" OVERALL (V.I.F.)
REAR ADDITION
(TO BE LEGALIZED)
V.I.F.
(E) 1'-0"
3'-2"
PR
O
P
.
L
I
N
E
.
DEMO PORTION
OF FLOOR SLAB
5'
-
0
"
PROP. LINE.
SHORING NOTES:
REVIEW STRUCTURAL DRAWINGS FOR
LOCATION OF NEW SLAB OVER EXISTING.
SHORE EXTERIOR WALLS AS NECESSARY TO
ACHIEVE THE OVERLAP. PROVIDE (N)
REDGARD WATERPROOFING AND CRACK
PREVENTION MEMBRANE PER ESR 1413
A201
3
A201 2
A201
4
A2011
A201
8
A2015
A201
7
A201 6
(N) BATH
20
'
-
2
"
18'-6"
3'-0"1'-0"
3'-7"
12'-10 1/4"5'-7 3/4"
4'-0"1'-8"3'-0"
3'-0"13'-4 1/2" OVERALL
CLR.
4'-0"
(N) TANKLESS
WTR HTR.
SEE GEN. PLUMBING NOTES
IN LEGEND BELOW
2
A
1'
-
6
"
E
3
4
5
4'
-
1
1
3
/
4
"
8'
-
4
1
/
2
"
6'
-
9
3
/
4
"
5'
-
0
"
C
L
R
18
'
-
7
"
O
V
E
R
A
L
L
(
V
.
I
.
F
.
)
(E
)
2
'
-
5
"
1'
-
1
"
3'
-
0
"
3'
-
2
"
MI
N
I
-
S
P
L
I
T
2'
-
6
"
C
4'
-
1
"
C
L
R
.
2
A401
3
A401
A301
1
A301
2
W1
W2
W3
W4
W5
101A
101B
101C
100AMP 120/240V,
1 PHASE, 3 WIRE
FEEDER
(N) ELECT.
SUB-PANEL
PR
O
P
.
L
I
N
E
.
PROP. LINE.
WASHER /
DRYER
2B
1
6
2'-8"6'-6"
D B
101D
1A
101E
268 SF
KITCHEN / LIVING
101
RR
103
CLOSET
104
226 SF
BEDROOM
102
2A
2B
1A
EXTERIOR DOORS @ +6 1/2"
FROM EXTERIOR GRADE
@ +6" FINISH FLOOR
EXTERIOR DOORS @ +6 1/2"
FROM EXTERIOR GRADE
(N) 6" CONCRETE SLAB OVER
EXISTING SLAB. SEE
STRUCTURAL DRAWINGS FOR
EPOXY DOWEL TRANSITIONS.
@ +6" FINISH FLOOR
(N) 6" CONCRETE SLAB OVER
EXISTING SLAB. SEE
STRUCTURAL DRAWINGS FOR
EPOXY DOWEL TRANSITIONS.
ISSUED
DATE:
REVISIONS
DRAWINGS, SPECIFICATIONS AND OTHER VISUAL AIDS, AS
INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE
DRAFTER/DESIGNER WHETHER THE PROJECT FOR
WHICH THEY ARE MADE BE EXECUTED OR NOT, AND
THEY ARE NOT TO BE USED FOR ANY OTHER SITE THAN
THE ONE FOR WHICH THEY ARE PREPARED, EXCEPT BY
AGREEMENT IN WRITING.
NO
.
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
DRAFTER/DESIGNER:
LUIS N OROZCO
562.661.9281
LUIS.OROZCO.A@LIVE.COM
DATE:
11/19/2024
A101
FLOOR PLANS
PR
O
P
E
R
T
Y
O
W
N
E
R
:
S
I
L
V
I
A
T
O
R
R
E
S
15
1
1
S
.
B
I
R
C
H
S
T
.
SA
N
T
A
A
N
A
,
C
A
9
0
7
2
7
GA
R
A
G
E
C
O
N
V
E
R
S
I
O
N
T
O
A
N
AC
C
E
S
S
O
R
Y
D
W
E
L
L
I
N
G
U
N
I
T
09/10/2024
NORTHNORTH
1
P
L
A
N
N
I
N
G
1
S
T
P
C
R
E
S
U
B
M
I
T
T
A
L
1
0
/
2
3
/
2
0
2
4
2
B
U
I
L
D
I
N
G
S
U
B
M
I
T
T
A
L
1
1
/
1
9
/
2
0
2
4
Scale:1/4" = 1'-0"1 FP - EXISTING / DEMO
Scale:1/4" = 1'-0"2 FP - PROPOSED
GENERAL PLUMBING NOTES:
1. SHOWER SHALL BE PROVIDED WITH INDIVIDUAL PRESSURE
BALANCE OR THERMOSTATIC MIXING CONTROL VALVES TO
PROVIDE SCALD AND THERMAL SHOCK PROTECTION. HANDLE
POSITION STOPS SHALL BE ADJUSTED TO DELIVER A MAXIMUM
MIXED WATER SETTING OF 120°F. [CPC 408.3].
2. WATER HEATER SHALL INCLUDE THE FOLLOWING COMPONENTS
[CENC 150.0(N)1]:
SYSTEMS USING GAS OR PROPANE WATER HEATER TO SERVICE INDIVIDUAL
DWELLING UNIT UNITS SHALL DESIGNATE A SPACE AT LEAST 2.5 FEET WIDE
AND 7 FEET TALL SUITABLE FOR THE FUTURE INSTALLATION OF A HEAT PUMP
HEATER (HPWH) BY MEETING EITHER A OR B BELOW. ALL ELECTRICAL
COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA
ELECTRICAL CODE:
A. IF THE DESIGNATED SPACE IS WITHIN 3 FEET FROM THE WATER HEATER,
THEN THIS SPACE SHALL INCLUDE THE FOLLOWING:
I. A DEDICATED 125-VOLT, 20 AMP ELECTRICAL RECEPTACLE
CONNECTED WITH A 120/240 VOLT 3 CONDUCTOR, 10 AWG COPPER BRANCH
CIRCUIT WITHIN 3 FEET FROM THE WATER HEATER AND ACCESSIBLE TO THE
WATER HEATER WITH NO OBSTRUCTIONS; AND
II. BOTH ENDS OF THE UNUSED CONDUCTOR SHALL BE LABEL
WITH THE WORD “SPARE”AND BE ELECTRICALLY ISOLATED; AND
III. A RESERVED SINGLE POLE CIRCUIT BREAKER SPACE IN THE
ELECTRICAL PANEL ADJACENT TO THE CIRCUIT BREAKER FOR THE BRANCH
CIRCUIT IN (A) ABOVE AND LABELED WITH THE WORDS “FUTURE 240V USE”;
AND
IV. A CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES
HIGHER THAN THE BASE OF THE INSTALLED WATER HEATER, AND ALLOWS
NATURAL DRAINING WITHOUT PUMP ASSISTANCE,
B. IF THE DESIGNATED SPACE IS MORE THAN 3 FEET FROM THE WATER
HEATER, THEN THIS SPACE SHALL INCLUDE THE FOLLOWING:
I. A DEDICATED 240 VOLT BRANCH CIRCUIT SHALL BE INSTALLED
WITHIN 3 FEET FROM THE DESIGNATED SPACE. THE BRANCH CIRCUIT SHALL
BE RATED AT 30 AMP MINIMUM. THE BLANK COVER SHALL BE IDENTIFIED AS
“240V READY”; AND
II. THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A
RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE
CIRCUIT BREAKER FOR A FUTURE HPWH INSTALLATION. THE RESERVED
SPACE SHALL BE PERMANENTLY MARKED AS “FOR FUTURE 240V USE”; AND
III. EITHER A DEDICATED COLD WATER SUPPLY, OR THE COLD
WATER SUPPLY SHALL PASS THROUGH THE DESIGNATED HPWH LOCATION
JUST BEFORE REACHING THE GAS OR PROPANE WATER HEATER; AND
IV. THE HOT WATER SUPPLY PIPE COMING OUT OF THE GAS OR
PROPANE WATER HEATER SHALL BE ROUTED FIRST THROUGH THE
DESIGNATED HPWH LOCATION BEFORE SERVING ANY FIXTURES; AND
V. THE HOT AND COLD WATER PIPING AT THE DESIGNATED HPWH
LOCATION SHALL BE EXPOSED AND READILY ACCESSIBLE FOR FUTURE
INSTALLATION OF AN HPWH; AND
VI. A CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES
HIGHER THAN THE BASE OF THE INSTALLED WATER HEATER, AND ALLOWS
NATURAL DRAINING WITHOUT PUMP ASSISTANCE.
C. WHEN A SECOND WATER HEATER IS INSTALLED AS PART OF AN ADDITION,
IT SHALL COMPLY WITH SECTION 150.2(a)(D).
GFIGFI
GF
I
D
GF
I
GFI
AF
C
I
AF
C
I
GFI
240V GFID
BUILDING WALL
BELOW
BUILDING WALL
BELOW
BUILDING WALL
BELOW
(E) ASPHALT COMP.
SHINGLES
(TO REMAIN)
(N) BUILT-UP ROOFING
22
'
-
2
"
20'-6"
5'
-
0
"
17
'
-
7
"
4'-0" CLR.13'-5 1/2"
1'-0"3'-0"
2
AE
E
5
1'
-
0
"
20
'
-
2
"
1'
-
0
"
11
'
-
8
"
13'-9"9"5'-0"
(N) ROOF
VENTS
(N) ROOF
VENTS
2%
S
L
O
P
E
PR
O
P
.
L
I
N
E
.
PROP. LINE.
1
6
D B
2%
S
L
O
P
E
B3
A501
DEMO. EAVE.
SEE DETAIL
B3/A501
B3
A501
(N) BUILT-UP ROOFING
MFG:GAF
Tri-Ply APP Granular Cap Sheet
ASTM D6222, type I, grade G
100AMP 120/240V,
1 PHASE, 3 WIRE
FEEDER
(N) 24"X36"
ACCESS
HATCH
GARBAGE
DISPOSAL
SWITCH
EXTERIOR-RATED
GFI OUTLET
EXHAUST FAN
MIN. 50 CFM
TV MOUNT OUTLET. GC TO
COORDINATE FINAL
LOCATION WITH OWNER
2
A
A
E
E
5
C
4'
-
6
"
9'
-
1
1
/
2
"
4'
-
6
"
EQ EQ
EQ EQ
EQ
EQ 4'-5"
EQ EQ
S
(N) ELECT.
SUBPANEL
RANGE HOOD
MIN. 280 CFM
RANGE
240V/
50 AMP
S
C
EQ
EQ
EQ EQ
EXTERIOR-RATED
GFI OUTLET
1
6
D B
S
C
HOOD
1/
2
"
/
1
2
"
SL
O
P
E
D
C
E
I
L
I
N
G
4'
-
6
"
EQ
EQ
4'
-
0
"
ELECTRICAL FLOOR PLAN NOTES
1. DUPLEX RECEPTACLE OUTLETS SHALL BE INSTALLED IN ALL ROOMS, AND AT MIN. AS FOLLOWS:
A. NOT MORE THAN 12'-0" O.C. ALONG WALLS.
B. NOT MORE THAN 6'-0" FROM OPENINGS.
C. ON ALL WALL SPACES 2'-0" WIDE AND WIDER AND ON THE WALL SPACE OCCUPIED BY FIXED GLASS PANELS.
2. ALL OUTLETS IN BATHROOM, AND WITHIN 6' OF SINKS SHALL BE G.F.I. CIRCUITS.
3. ALL NEW ELECTRICAL INSTALLATIONS AND LIGHTING FIXTURES SHALL BE IN COMPLIANCE WITH 2019 ENERGY CODE.
4. LOCATE ALL RECEPTACLE AND ELECTRICAL OUTLET 18" MIN ABOVE F.F. TO THE CENTER OF RECEPTACLE UNIT.
5. BATHROOM SHALL BE PROVIDED WITH MIN. 50 CFM INTERMITTENT VENTILATION EXHAUSTED DIRECTLY TO THE OUTSIDE
(R303.3) WITH HUMIDISTAT CONTROL.
6. PROVIDE FIRE RATED BLOCKING "METALCAULK BOX GUARD" AT FIRE RATED OUTLET NOTED IN PLAN TO PREVENT
DISCONTINUITY ON THE RATING. FIRE BLOCKING SHALL BE INSTALL IN ACCORDANCE TO UL 263 / ASTM E119 STANDARD, "FIRE
TEST OF BUILDING CONSTRUCTION MATERIALS."
7. INTERCONNECTED, HARD-WIRED SMOKE ALARMS WITH BATTERY BACK-UP SHALL BE INSTALLED PER CRC R314.
8. INTERCONNECTED, HARD-WIRED CARBON MONOXIDE ALARMS (UL 2034/2075 RATED) W ITH BATTERY BACK-UP SHALL BE
INSTALLED PER CRC R315.
9. ARC-FAULT (AFCI) CIRCUIT-INTERUPTER SHALL BE PROVIDED AS REQUIRED IN 210.12(A),(B),(C) AND (D).
10. INSTALL GROUNDING WITH 20' UFER GROUND IN FOOTING EITHER NO.4 AWG OR LARGER BARE COPPER CONDUCTOR OR #4
OR LARGER REBAR, BOND, TO WATER LINE.
11. PROVIDE AN ISOLATED 20AMP CIRCUIT FOR THE RECEPTACLES IN EACH BATHROOM.
12. PROVIDE TWO 20AMP SMALL-APPLIANCE CIRCUITS FOR THE RECEPTACLES IN THE KITCHEN.
13. PROVIDE ONE 20AMP CIRCUIT FOR THE RECEPTACLES IN THE LAUNDRY ROOM.
14.PROVIDE A SEPARATE #12 AWG WIRE BRANCH CIRCUIT FOR THE RECEPTACLE AT GARBAGE DISPOSAL.
15. PROVIDE A SEPARATE 20AMP CIRCUIT FOR EACH FIXED APPLIANCE, SUCH AS GARBAGE DISPOSAL, DISHWASHER, W ASHING
MACHINE, DRYER, BUILT-IN REFRIGERATOR OR FREEZER, FURNACE, AIR CONDITIONING OR BUILT-IN HEATERS, WITH A MOTOR
OF 1/4HP OR LARGER.
16. INSTALL AT LEAST ONE GFCI RECEPTACLE IN FRONT AND ANOTHER IN THE BACK OF HOUSE. OUTSIDE RECEPTACLES SHALL
HAVE AN IN-USE ENCLOSURE.
17. INSTALL KITCHEN RECEPTACLES AT +42" ABOVE FINISH FLOOR.
18. INSTALL RECEPTACLES IN KITCHEN EVERY 4' ABOVE THE COUNTER. NO POINT ON THE KITCHEN WALL SHALL BE LOCATED
MORE THAN 24" FROM A RECEPTACLE OUTLET.
19. ALL OUTLETS SHALL BE TAMPER RESISTANT (CHILD PROOF).
20. PROVIDE A RECEPTACLE AND A LIGHT WITH SWITCH AT ATTIC ACCESS.
21. PRIMARY LIGHTING AT BATHS AND KITCHEN SHALL BE FLUORESCENT TYPE.
22. FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE OUTSIDE THE BUILDING.
23. UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, FANS MUST BE CONTROLLED BY A
HUMIDITY CONTROL.
A. HUMIDITY CONTROLS SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A ELATIVELY HUMIDITY RANGE OF LESS OR
EQUAL TO 50% TO A MAXIMUM OF 80%. A HUMIDITY CONTROL MAY UTILIZE MANUAL OR AUTOMATIC MEANS OF
ADJUSTMENT.
B. A HUMIDITY CONTROL MAY BE A SEPARATE COMPONENT TO THE EXHAUST FAN AND IS NOT REQUIRED TO BE
INTEGRAL (I.E. BUILT-IN).
24. SMOKE ALARMS SHALL BE INSTALLED NOT LESS THAN 3 FEET HORIZONTALLY FROM THE DOOR OR DOOR OPENING OF A
BATHROOM THAT CONTAINS A BATHTUB OR SHOWER UNLESS THIS WOULD PREVENT PLACEMENT OF THE SMOKE ALARM
REQUIRED BY CRC SECTION R314.3.
25. CARBON MONOXIDE ALARMS SHALL BE PROVIDED OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY
OF THE BEDROOMS.
SYMBOL DESCRIPTION
(E) 6" RECESSED CAN LIGHT
(N) 6" RECESSED CAN LIGHT
ELECTRICAL LIGHTING LEGEND
ENERGY STAR LIGHT-ACTIVATED EXHAUST FAN
(SEE NOTE #5 FOR MORE INFO)
DOWN LIGHT @ SHOWER -(WT)S
SWITCH -SINGLES
2
S SMOKE ALARM (SEE NOTE #7)
CARBON MONOXIDE ALARM (SEE NOTE #8)C
NOTE: (WT) WET LOCATION LIGHTING FIXTURE
SYMBOL DESCRIPTION
PENDANT LIGHT
S SWITCH -DOUBLE
OUTLET -SINGLE
OUTLET -DUPLEX -AFCI/TR
CEILING FANSSWITCH -THREE WAY3
S SWITCH -DIMMERD
OUTLET -DUPLEX -GFI -115VL/240VL SEE PLANGFI
FR OUTLET DUPLEX -FIRE RATED
OUTLET -TRIPLE
OUTLET -QUAD
REFLECTED CEILING PLAN LEGEND (EXISTING/ NEW)
(N) GYP BD. HARD LID CEILING
(N) HVAC SUPPLY
(N) HVAC RETURN
GENERAL NOTE:
CONTRACTOR TO PROVIDE SMOKE DETECTOR IN EACH SLEEPING ROOM AND
AT A POINT CENTRALLY LOCATED IN THE CORRIDOR OF AREA GIVING ACCESS
TO EACH SEPARATE SLEEPING AREA AND IN EACH STORY OR BASEMENT; AND
IF SLEEPING ROOMS ARE AT AN UPPER LEVEL, PROVIDE A DETECTOR AT THE
CEILING OF THE UPPER LEVEL IN CLOSE PROXIMITY TO THE STAIRWAY IF
APPLICABLE (SEC 310.9.14 IBC).
MINIMUM ATTIC VENT AREA SHALL BE PER 2022 CRC R806.2.
ATTIC FLOOR SPACE (ADU)= 373 SF
373 SF / 150 = 2.48 SF X 144 = 358.08 SQ. IN.
MIN. VENT REQ. = 358.08 SQ IN.
PROVIDED VENT AREA:
4 (24"X16") ROOF VENTS = 1,536 SQ. IN.
TOTAL VENT AREA PROVIDED = 1,536 SQ. IN
1,536 SQ. IN. > 358.08 SQ. IN.
ATTIC VENT AREA CALC.
SWITCH -W/ VACANCY SENSOR
ENERGY COMPLIANCE:
1. EXHAUST FANS SHALL BE SWITCHED SEPARATELY FROM LIGHTING SYSTEM. LIGHTING INTEGRAL TO AN EXHAUST FAN MAY
BE ON THE SAME SWITCH AS THE FAN PROVIDED THE LIGHTING CAN BE SW ITCHED OFF WHILE ALLOWING THE FAN TO
CONTINUE TO OPERATE FOR AN EXTENDED PERIOD OF TIME. (150(K)2B CEC)
2. IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE LUMINAIRE IN EACH OF THESE SPACES
SHALL BE CONTROLLED BY A VACANCY SENSOR. (150(K)2J CEC)
3. ALL JA8 COMPLAINT LIGHT SOURCES, EXCEPT THOSE IN CLOSETS LESS THAN 70 SQUARE FEET AND THOSE IN HALLWAYS,
SHALL BE CONTROLLED BY DIMMERS OR VACANCY SENSORS. (150(K)2K & TABLE 150.0-A CEC) JA8 COMPLIANT LIGHT SOURCES
INCLUDE LIGHT SOURCES IN CEILING RECESSED DOWNLIGHT LUMINAIRES AND GU-24 SOCKETS CONTAINING LED LIGHT
SOURCES.
4. ALL RESIDENTIAL OUTDOOR LIGHTING PERMANENTLY MOUNTED TO THE RESIDENCE OR OTHER BUILDINGS ON THE SAME
LOT SHALL BE HIGH-EFFICACY AND MEET THE FOLLOWING REQUIREMENTS: (150(K)3A CEC)
A. LIGHTS SHALL COMPLY WITH ONE OF THE TWO OPTIONS BELOW:
1. CONTROLLED BY A PHOTOCELL AND MOTION SENSOR. CONTROLS THAT OVERRIDE TO ON SHALL NOT
BE ALLOWED UNLESS THE OVERRIDE AUTOMATICALLY REACTIVATES THE MOTION SENSOR WITHIN 6
HOURS.
2. CONTROLLED BY (1) PHOTOCONTROL AND AUTOMATIC TIME SWITCH CONTROL OR (2) ASTRONOMICAL
TIME CLOCK OR (3) ENERGY MANAGEMENT CONTROL SYSTEM MEETING THE REQUIREMENTS OF
150(K)3A.
B. LIGHTS SHALL BE CONTROLLED BY A MANUAL ON AND OFF SWITCH THAT DOES NOT OVERRIDE TO ON THE
AUTOMATIC ACTIONS OF ITEM I OR ITEM II CHOSEN ABOVE.
EXTERIOR WALL SCONCE W/ PHOTOCELL SENSOR
SV
P
(N) WHOLE HOUSE FAN MINIMUM UNDER-FLOOR VENT AREA SHALL BE PER R408.1
UNDER-FLOOR SPACE (ADU)= N/A
CONCRETE SLAB ON GRADE
UNDER-FLOOR VENTILATION AREA CALC.
26. ALL LIGHTING SHALL BE HIGH EFFICACY
27. SYSTEMS USING GAS OR PROPANE COOKTOP TO SERVE INDIVIDUAL DW ELLING UNITS SHALL INCLUDE A DEDICATED 240
VOLT BRANCH CIRCUIT WIRING INSTALLED WITHIN 3 FEET FROM THE COOKTOP AND ACCESSIBLE TO THE COOKTOP WITH NO
OBSTRUCTIONS. THE BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT 50 AMPS MINIMUM. THE BLANK COVER SHALL BE
IDENTIFIED AS "240V READY." ALL ELECTRICAL COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA
ELECTRICAL CODE. (CEnC 150.0(u))
28. CLOTHES DRYER LOCATIONS WITH GAS OR PROPANE PLUMBING TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE A
DEDICATED 240 VOLT BRANCH CIRCUIT WIRING INSTALLED WITHIN 3 FEET FROM THE CLOTHES DRYER LOCATION AND
ACCESSIBLE TO THE CLOTHES DRYER LOCATION WITH NO OBSTRUCTIONS. THE BRANCH CIRCUIT CONDUCTORS SHALL BE
RATED AT 30 AMPS MINIMUM. THE BLANK COVER SHALL BE IDENTIFIED AS "240V READY." ALL ELECTRICAL COMPONENTS SHALL
BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA ELECTRICAL CODE (CEnC 150.0(v))
29. ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS (INCLUDING CONTROLS FOR HEATING, VENTILATION AND
AIR CONDITIONING) INTENDED TO BE USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48 IN. MEASURED FROM THE
TOP OF THE OUTLET BOX AND NOT LESS THAN 15 IN. MEASURED FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISH
FLOOR. (CRC R327.1.2)
30. DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT EXCEED 48 IN. ABOVE EXTERIOR FLOOR OR LANDING,
MEASURED FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. WHERE DOORBELL BUTTONS INTEGRATED WITH OTHER
FEATURES ARE REQUIRED TO BE INSTALLED ABOVE 48 IN. MEASURED FROM THE EXTERIOR FLOOR OR LANDING, A STANDARD
DOORBELL BUTTON OR CONTROL SHALL ALSO BE PROVIDED AT A HEIGHT NOT EXCEEDING 48 IN. ABOVE EXTERIOR FLOOR OR
LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON OR CONTROL. (CRC R327.1.4)
17
'
-
8
"
DEMO ROOF
DEMO ROOF
(E) BUILDING WALL
BELOW
BUILDING WALL
BELOW
BUILDING WALL
BELOW
(E) ASPHALT COMP. SHINGLES
(TO REMAIN)
(N) BUILT-UP ROOFING
MFG:GAF
Tri-Ply APP Granular Cap Sheet
ASTM D6222, type I, grade G
9"
1'
-
0
"
1'-0"
1'
-
0
"
1'-0"
18'-9"
1'-9"
PR
O
P
.
L
I
N
E
.
PROP. LINE.
3
1
/
2
"
/
1
2
"
3 1/2" / 12"
2%
S
L
O
P
E
DEMO. EAVE.
SEE DETAIL
B3/A501
ISSUED
DATE:
REVISIONS
DRAWINGS, SPECIFICATIONS AND OTHER VISUAL AIDS, AS
INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE
DRAFTER/DESIGNER WHETHER THE PROJECT FOR
WHICH THEY ARE MADE BE EXECUTED OR NOT, AND
THEY ARE NOT TO BE USED FOR ANY OTHER SITE THAN
THE ONE FOR WHICH THEY ARE PREPARED, EXCEPT BY
AGREEMENT IN WRITING.
NO
.
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
DRAFTER/DESIGNER:
LUIS N OROZCO
562.661.9281
LUIS.OROZCO.A@LIVE.COM
DATE:
11/19/2024
A102
REFLECTED CEILING PLAN
& ROOF PLAN
PR
O
P
E
R
T
Y
O
W
N
E
R
:
S
I
L
V
I
A
T
O
R
R
E
S
15
1
1
S
.
B
I
R
C
H
S
T
.
SA
N
T
A
A
N
A
,
C
A
9
0
7
2
7
GA
R
A
G
E
C
O
N
V
E
R
S
I
O
N
T
O
A
N
AC
C
E
S
S
O
R
Y
D
W
E
L
L
I
N
G
U
N
I
T
09/10/2024
Scale:1/4" = 1'-0"1 RP - PROPOSED
Scale:1/4" = 1'-0"2 RCP - PROPOSED
2
B
U
I
L
D
I
N
G
S
U
B
M
I
T
T
A
L
1
1
/
1
9
/
2
0
2
4
NORTHNORTH
Scale:1/4" = 1'-0"3 RP - EXISTING
NORTH
FIN. FLOOR
0' -1"
(E) GRADE
0' -0"
T.O.P.
8' -8"
T.O. ROOF
11' -8"
1'-0"
3'-2"
PR
O
P
.
L
I
N
E
.
DEMO. PORTION
OF ROOF & WALL
1'-10"
TRIM EAVE
FIN. FLOOR
0' -1"
(E) GRADE
0' -0"
T.O.P.
8' -8"
T.O. ROOF
11' -8"
PR
O
P
.
L
I
N
E
.
(E) POOL
SHOWER
W2W4
103D
W5
DEMO. PATIO
COVER
FIN. FLOOR
0' -1"
(E) GRADE
0' -0"
T.O.P.
8' -8"
T.O. ROOF
11' -8"
PR
O
P
.
L
I
N
E
.
DEMO. PORTION
OF ROOF & WALL
DEMO. PATIO
COVER
FIN. FLOOR
0' -1"
(E) GRADE
0' -0"
T.O.P.
8' -8"
T.O. ROOF
11' -8"
PR
O
P
.
L
I
N
E
.
DEMO. GARAGE DR.
& PATIO COVER
TRIM EAVE
(E) GRADE
0' -0"
T.O.P.
8' -8"
T.O. ROOF
11' -8"
5'-0"
(N) TANKLESS
WTR HTR
(N) MINI SPLIT
PR
O
P
.
L
I
N
E
.
W2
W3
W4W5
EXT. RATED GFI
(E) POOL
SHOWER
(N) FIN. FLOOR
0' -6"
6"
C1
A501
C3
A501
101E
(E) GRADE
0' -0"
T.O.P.
8' -8"
T.O. ROOF
11' -8"
PR
O
P
.
L
I
N
E
.
3
A401
7'
-
1
0
"
@WALL
5'-0"
(N) PORCH
COVER
(N) STUCCO
FINISH & COLOR
TO MATCH EXISTING
(N) FIN. FLOOR
0' -6"
(E) GRADE
0' -0"
T.O.P.
8' -8"
T.O. ROOF
11' -8"
(N) TANKLESS
WTR HTR
(N) MINI SPLIT
4'-0"
1'-0"
PR
O
P
.
L
I
N
E
.
EXT. RATED GFI W/
WEATHER PROOF
COVER
(E) ASPHALT
COMP. SHINGLES (E) BUILT-UP
ROOFING
(N) FIN. FLOOR
0' -6"
(E) EXTERIOR
SHOWER
(E) GRADE
0' -0"
T.O.P.
8' -8"
T.O. ROOF
11' -8"
1'-0"
5'-0"
PR
O
P
.
L
I
N
E
.
2
A401
101A W1
(N) PORCH
COVER
(E) ASPHALT
COMP. SHINGLES
6"
(N) FIN. FLOOR
0' -6"
3'
-
0
"
(N) PATIO KICKERS
6'
-
5
"
A502
B3
D1
A501
D2
A501
ISSUED
DATE:
REVISIONS
DRAWINGS, SPECIFICATIONS AND OTHER VISUAL AIDS, AS
INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE
DRAFTER/DESIGNER WHETHER THE PROJECT FOR
WHICH THEY ARE MADE BE EXECUTED OR NOT, AND
THEY ARE NOT TO BE USED FOR ANY OTHER SITE THAN
THE ONE FOR WHICH THEY ARE PREPARED, EXCEPT BY
AGREEMENT IN WRITING.
NO
.
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
DRAFTER/DESIGNER:
LUIS N OROZCO
562.661.9281
LUIS.OROZCO.A@LIVE.COM
DATE:
10/23/2024
A201
EXTERIOR ELEVATIONS
PR
O
P
E
R
T
Y
O
W
N
E
R
:
S
I
L
V
I
A
T
O
R
R
E
S
15
1
1
S
.
B
I
R
C
H
S
T
.
SA
N
T
A
A
N
A
,
C
A
9
0
7
2
7
GA
R
A
G
E
C
O
N
V
E
R
S
I
O
N
T
O
A
N
AC
C
E
S
S
O
R
Y
D
W
E
L
L
I
N
G
U
N
I
T
09/10/2024
NOTE: (N) EXTERIOR STUCCO FINISH/COLOR WALLS
AND ASPHALT COMP. SHINGLES TO MATCH
EXISTING PRIMARY STRUCTURE.
1
P
L
A
N
N
I
N
G
1
S
T
P
C
R
E
S
U
B
M
I
T
T
A
L
1
0
/
2
3
/
2
0
2
4
Scale:1/4" = 1'-0"3 (E) EAST
Scale:1/4" = 1'-0"1 (E) NORTH
Scale:1/4" = 1'-0"2 (E) SOUTH
Scale:1/4" = 1'-0"4 (E) WEST
Scale:1/4" = 1'-0"5 (N) NORTH
Scale:1/4" = 1'-0"6 (N) SOUTH
Scale:1/4" = 1'-0"7 (N) EAST
Scale:1/4" = 1'-0"8 (N) WEST
NOTE: TANKLESS WATER HEATER TO BE
WITHIN AN ENCLOSURE THAT MATCHES
THE COLOR AND MATERIAL OF THE ADU.
6"
3'
-
0
"
6"
3'
-
0
"
3'
-
7
"
TEMPERED
GLAZING
7'
-
0
"
4"
TEMPERED
GLAZING
7'
-
0
"
4"
4'
-
0
"
3'
-
0
"
30" MIN.
8'
-
0
"
SH
O
W
E
R
2'
-
6
"
DA
M
4
1
/
2
"
5'-0"
EQ
EQ
30
"
M
I
N
.
3'
-
1
1
/
2
"
VA
N
I
T
Y
2'
-
0
"
24" MIN.
2'-4 1/2"
RANGE
2'-0"1"
CABINETS
4'-6"1"
REF
2'-0"
CO
U
N
T
E
R
T
O
P
2'
-
1
"
A301 2B
2A
B
8'-8"
30
"
C
L
R
.
CLEAR
4'-1 1/2"
30
"
C
L
R
KITCHEN
HOOD
GFI
EQEQEQ2'-2"
2'-6"1'-0"1'-0"2'-0"2'-0"
A502
D1
TYP
ISSUED
DATE:
REVISIONS
DRAWINGS, SPECIFICATIONS AND OTHER VISUAL AIDS, AS
INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE
DRAFTER/DESIGNER WHETHER THE PROJECT FOR
WHICH THEY ARE MADE BE EXECUTED OR NOT, AND
THEY ARE NOT TO BE USED FOR ANY OTHER SITE THAN
THE ONE FOR WHICH THEY ARE PREPARED, EXCEPT BY
AGREEMENT IN WRITING.
NO
.
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
DRAFTER/DESIGNER:
LUIS N OROZCO
562.661.9281
LUIS.OROZCO.A@LIVE.COM
DATE:
A301
ENLARGED FLOOR PLANS
& INTERIOR ELEVATIONS
PR
O
P
E
R
T
Y
O
W
N
E
R
:
S
I
L
V
I
A
T
O
R
R
E
S
15
1
1
S
.
B
I
R
C
H
S
T
.
SA
N
T
A
A
N
A
,
C
A
9
0
7
2
7
GA
R
A
G
E
C
O
N
V
E
R
S
I
O
N
T
O
A
N
AC
C
E
S
S
O
R
Y
D
W
E
L
L
I
N
G
U
N
I
T
09/10/2024
Scale:1/2" = 1'-0"1A BATHROOM - TYP.
Scale:1/2" = 1'-0"1B BATHROOM - TYP.
Scale:1/2" = 1'-0"1C BATHROOM - TYP.
Scale:1/2" = 1'-0"1D BATHROOM - TYP.
PER CRC SECTION R327, BATHROOM SHALL BE PROVIDED WITH REINFORCEMENT INSTALLED
AS FOLLOWS:
1. REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS
APPROVED BY THE ENFORCING AGENCY.
2. REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 IN. NOMINAL LUMBER. OR OTHER
CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD CAPACITY. REINFORCEMENT
SHALL BE LOCATED BETWEEN 32 IN. AND 39 1/4 IN. ABOVE THE FINISHED FLOOR FLUSH WITH
THE WALL FRAMING.
3. WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE
FIXTURE, OR ONE SIDE WALL AND THE BACK WALL.
4. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED.
5. BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS
ON EACH END OF THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL
REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE
LOCATED NO MORE THAN 6 IN. ABOVE THE BATHTUB RIM.
Scale:1/2" = 1'-0"1 FP - BATH (ENLARGED)
Scale:1/2" = 1'-0"2 FP - KITCHENETTE (ENLARGED)
Scale:1/2" = 1'-0"2B KITCHENETTE (SOUTH)
Scale:1/2" = 1'-0"2A KITCHENETTE (EAST)
WASHER &
DRYER
1/2" WOOD STR. PANEL, REF.
STRUC. DRAWINGS
2X6 DOUBLE TOP PLATE
2X SOLID BLOCKING W/ APPROVED
FRAMING CLIPS EA. BLOCK
1/2" CDX PLY SHEATHING W/8d @ 6"/6"/12"
O.C. (COMMON NAILS) REFERENCE
STRUCTURAL DRAWINGS.
ASPHALT COMPOSITE SHINGLES. SEE ROOF
PLAN FOR COOL ROOF CALL-OUT.
ROOF RAFTERS, SEE STRUCTURAL
DRAWINGS.
7/8" CEMENT PLASTER OVER MTL
LATH OVER (2) LAYERS OF GRADE 'D'
PAPER, TYP.
ATTIC VENT BEYOND
CEILING JOIST, SEE STRUCTURAL
DRAWINGS FOR REFERENCE, W/
BATT INSUL. OVER 5/8" GYP. HARD-LID
CEILING TYP.
2"X STUD WALL @ 16" O.C. (DF STUD
GRADE-MINIMUM) W/ (BATT)
WHERE OCCURS. SEE WALL SCHEDULE
FOR WALL TYPES.
@ RATED ROOF END
R-15
R-30
@ RATED EXTERIOR SOFFIT: 7/8"
CEMENT PLASTER OVER MTL LATH
OVER (2) LAYERS OF GRADE 'D'
PAPER, TYP.
A501
A1
4"
2X P.T. SILL W/12"X10" A.B. @ 6' O.C.
0.229" X 3" X 3" PLATE WASHERS
INTERIOR SPACE
A501
B2
(E) FINISH SURFACE
0'-0"
T.O. SILL PLATE
7'-10"
TY
P
.
4"
2'
-
0
"
1'-0"
(E) GRADE
0' -0"
T.O.P.
8' -8"
T.O. ROOF
11' -8"
2 3 4 5
3
A401
8'
-
8
1
/
4
"
1 6
(N) FIN. FLOOR
0' -6"
R-30 BATT INSULATION
@ FLAT ROOF
7'
-
1
0
"
7'
-
4
"
R-30 BATT INSULATION
@ CEILING
1'
-
8
"
3'
-
0
"
(E) GRADE
0' -0"
T.O.P.
8' -8"
T.O. ROOF
11' -8"
AEC
2
A401
(N) FIN. FLOOR
0' -6"
7'
-
1
0
"
A401
1
3'
-
0
"
ISSUED
DATE:
REVISIONS
DRAWINGS, SPECIFICATIONS AND OTHER VISUAL AIDS, AS
INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE
DRAFTER/DESIGNER WHETHER THE PROJECT FOR
WHICH THEY ARE MADE BE EXECUTED OR NOT, AND
THEY ARE NOT TO BE USED FOR ANY OTHER SITE THAN
THE ONE FOR WHICH THEY ARE PREPARED, EXCEPT BY
AGREEMENT IN WRITING.
NO
.
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
DRAFTER/DESIGNER:
LUIS N OROZCO
562.661.9281
LUIS.OROZCO.A@LIVE.COM
DATE:
04/24/25
A401
WALL SECTIONS
PR
O
P
E
R
T
Y
O
W
N
E
R
:
S
I
L
V
I
A
T
O
R
R
E
S
15
1
1
S
.
B
I
R
C
H
S
T
.
SA
N
T
A
A
N
A
,
C
A
9
0
7
2
7
GA
R
A
G
E
C
O
N
V
E
R
S
I
O
N
T
O
A
N
AC
C
E
S
S
O
R
Y
D
W
E
L
L
I
N
G
U
N
I
T
09/10/2024
3
B
U
I
L
D
I
N
G
S
U
B
M
I
T
T
A
L
#
2
0
4
/
2
4
/
2
5
Scale:1/2" = 1'-0"1 WALL SECTION TYPE B
Scale:1/4" = 1'-0"2 BUILDING SECTION A
Scale:1/4" = 1'-0"3 BUILDING SECTION B
3
3
GYPSUM BOARD
DOOR AS SCHEDULED, SEE
FLOOR PLANS FOR DOOR
SWING
WALL PER WALL
TYPES.
WOOD FRAMING
HEADER, TYP.
5/
8
"
2"
22 GAGE GALV. SHEET
METAL DRIP EDGE
CONT. BACKER ROD
& SEALANT, TYP.
SELF-ADHERED FLEXIBLE
FLASHING, TYP.
2"2"
1/2"
7/8" EXTERIOR PLASTER
OVER METAL LATH OVER
(2) LAYERS OF GRADE D.
60 MIN. ASPHALTIC PAPER
CONT. PLASTER HEAD
FLASHING. PAINTED TO
MATCH EXTERIOR FINISH.
EXTERIOR DOOR PER SCHEDULE, SEE FLOOR
PLANS FOR DOOR SWING
FINISH FLOOR PER
OWNER
ALUMINUM THRESHOLD, SET
IN FULL BED OF MASTIC
LINE OF DOORSTOP BEYOND
LINE OF FRAME
BEYOND
2
1 MAX.
ANCHOR @ 24" O.C. 6"@
ENDS, 2" MIN. EMBEDMENT
EXTERIOR
CONCRETE
EL
E
V
.
SE
E
E
X
T
.
ALLOW PROPER AIR VENTILATION.
PROVIDE INSECT SCREEN WITH
STAGGERED PERFORATIONS.
PROVIDE 1" SPACE BETWEEN
INSULATION AND ROOF SHEETHING
WALL PER WALL TYPES.
15/32" WOOD STR. PANEL, REF. STRUC.
DRAWINGS
2X RAFTER PER STRUCTURAL
DRAWINGS
(2) 2X4 TOP PLATE
EDGE NAIL
UPLIFT FRAMING CLIP PER
TABLE R802.11
1/2" CDX PLY SHEATHING W/8d @
6"/6"/12" O.C. (COMMON NAILS)
REFERENCE STRUCTURAL DRAWINGS.
SIMPSON TIE PER STRUCTURAL
DRAWINGS
2X BLKG.
B.N. 8D @ 6" O.C.
2X FASCIA W/ 2# 10X 3" LONG
WOOD SCREWS @ EACH RAFTER
(8) 16D NAILS MIN.
FLASHING W/
CAULKING
SELF-ADHERED
FLEXIBLE FLASHING
5/8" GYP. BD.
(2) LAYERS OF GRADE D
BLDG PAPER, TYP. EXT.
PLYWOOD SHEATHING.
GALV. SHEET METAL
WEEP SCREED -
PROVIDE MIN. 3 1/2"
ATTACHMENT FLANGE
2X P.T. SILL W/ 1/2" X 10" ANCHOR
BOLTS @ 6' O.C. &
0.229" X 3" X 3" PLATE WASHERS
EXT.FINISHED
GRADE. SLOPE
TO DRAIN.
7/8" EXTERIOR
PLASTER OVER
METAL LATH
PLASTER NOTE:
EXTERIOR PLASTER (STUCCO) WALL SHALL
BE PROVIDED WITH A CORROSION
RESISTANT WEEP SCREED COMPLYING
WITH SECTION R703.7.2.1
TEXTURED
TERMINATION TAPE
UNDERSLAB VAPOR
BARRIER (10 MIL
VISQUEEN)
2" SAND OVER
6 MIL VISQUEEN CONT. URETHANE
SEALANT
SEALANT AND
BACKER ROD
BATT. INSULATION
GC TO PROVIDE MOISTURE
BARRIER COATING WHERE 6 MIL
VISQUEEN IS NOT ABLE TO BE
CONFIRMED.
GC. TO CONFIRM (E) CONC. CURB
WD. BASE BOARD
8"
M
I
N
.
24
"
T
Y
P
12" MIN.
(2) -#4 BAR, TOP
(2) -#4 BAR, BOTTOM
3"
C
L
R
.
3-1/2" CONC. SLAB, #4 DEFORMED
REINF. @16" O.C. EA WAY
FOOTING NOTE:
GC TO FIELD VERIFIED EXISTING FOOTING
CONDITION FOR OVERALL COMPLIANCE, ADJUST
AS REQ. SEE STRUCTURAL DRAWINGS AND
DETAILS FOR FURTHER INFORMATION.
5/8" GYP BD.
WOOD HEADER,
PER STRUCTURAL
WINDOW FRAME.
CONT. SEALANT &
BACKER ROD, TYP.
SELF-ADHERED FLEXIBLE
FLASHING, TYP.
24 GA. SHEET METAL
DRIP, SET IN A CONT.
BED OF SEALANT. TYP.
GLAZING PER
WINDOW TYPES, TYP.
J-MOLD,
TYP.
V.I.F.
7/8" CEMENT PLASTER
OVER MTL LATH OVER (2)
LAYERS OF GRADE D
BLDG PAPER, TYP.
INT. WINDOW FASCIA TRIM
PER MFG.
1/2" TYP.
BATT INSULATION
NOTE:
1. CONTRACTOR SHALL VERIFY COMPATIBILITY BETWEEN MATERIALS PRIOR TO
INSTALLATION OF ANY WATERPROOFING OR WATER BARRIER MATERIALS.
2. SEE DETAIL NO.7 FOR TYPICAL WINDOW FLASHING. G.C. SHALL COORDINATE AS REQUIRED
CONT. BACKER ROD &
SEALANT
GYP. BD.
GALV. SHEET METAL WEEP
SCREED -PROVIDE MIN. 3
1/2" ATTACHMENT FLANGE
2X P.T. SILL W/ ANCHOR BOLTS
AND PLATE WASHERS
2X RIM JOIST
CONC. STEM WALL
PLASTER NOTE:
EXTERIOR PLASTER (STUCCO)
WALL SHALL BE PROVIDED WITH A
CORROSION RESISTANT WEEP
SCREED COMPLYING WITH SECTION
R703.7.2.1
FOOTING NOTE:
1. SEE STRUCTURAL
DRAWINGS AND DETAILS FOR
FURTHER INFORMATION.
2. WEEP SCREED FOR EXT.
PLASTER SHALL BE 4" MIN.
ABOVE EARTH OR 2" ABOVE
PAVED AREAS. INSTALL AS
REQ.
(2) LAYERS OF GRADE D BLDG
PAPER, TYP. EXT. PLYWOOD
SHEATHING.
7/8" EXTERIOR PLASTER OVER
METAL LATH
TEXTURED TERMINATION TAPE
SEALANT AND BACKER ROD
FLASHING W/ CAULKING
EXT.FINISHED GRADE.
SLOPE TO DRAIN.
CONT. URETHANE SEALANT
SELF-ADHERED
FLEXIBLE FLASHING
4"
M
I
N
.
UNDERFLOOR VENTS BEYOND EXTERIOR
DOOR PER SCHEDULE, SEE FLOOR
PLANS FOR DOOR SWING
FINISH FLOOR PER
OWNER
ALUMINUM THRESHOLD, SET
IN FULL BED OF MASTIC
LINE OF DOORSTOP BEYOND
LINE OF FRAME
BEYOND
2
1 MAX.
ANCHOR @ 24" O.C. 6"@
ENDS, 2" MIN. EMBEDMENT
EXTERIOR
LANDING
1/
4
"
3/
4
"
5/8" GYP BD.
WOOD STUD, PER
STRUCTURAL
WINDOW FRAME.
CONT. SEALANT &
BACKER ROD, TYP.
SELF-ADHERED FLEXIBLE
FLASHING, TYP.
GLAZING PER
WINDOW TYPES, TYP.V.I.F.
7/8" CEMENT PLASTER
OVER MTL LATH OVER (2)
LAYERS OF GRADE D
BLDG PAPER, TYP.
INT. WINDOW FASCIA TRIM
PER MFG.
1/2" TYP.
BATT INSULATION
NOTE:
1. CONTRACTOR SHALL VERIFY COMPATIBILITY BETWEEN MATERIALS PRIOR TO
INSTALLATION OF ANY WATERPROOFING OR WATER BARRIER MATERIALS.
2. SEE DETAIL NO.7 FOR TYPICAL WINDOW FLASHING. G.C. SHALL COORDINATE AS REQUIRED
MANUFACTURER APPROVED
WEATHER BARRIER
SIDING NOTES:
-BLIND NAIL ATTACHMENT
-STAGGER JOINTS ON ALL WALLS LESS THAN 11'-0" IN
LENGTH (ALLOW FOR MITER AT ALL CORNERS)
-INSTALL JOINT FLASHING AT ALL JOINTS INCLUDING
BUTT JOINTS AND LAP JOINT AT END OF PLANKS, PER
MANUFACTURE'S WRITTEN RECOMMENDATIONS.
-MAINTAIN MIN. CLEAR GAP OF 1/4" BETWEEN WEEP
SCREED FLASHING & BOTTOM OF HARDIE PLANK
-SHIM FURRING TO MAINTAIN STRAIGHTNESS OF
SIDING APPLICATION.
TY
P
.
1
1
/
4
"
M
I
N
.
TY
P
.
1
1
/
4
"
M
I
N
.
TY
P
.
1
1
/
4
"
M
I
N
.
6" HARDIE PLANK SIDING OR EQUAL
5/8" FIBER CEMENT LAP SIDING
ATTACHED W/ (RIBBED WAFER-
HEAD No. 8 0.375" X 1 1/4" @ 16" O.C.)
TY
P
.
3/
4
"
1-HR RATED SOFFIT
7/8" EXTERIOR PLASTER ON METAL
LATH OVER (2) LAYERS BLDG PAPER
OVER 1/2" EXT. PLYWOOD SHEATHING
STARTER BLOCK
SHT. MTL. FLASHING
J-MOLDING
RIDGE BOARD. NAILING
PATTER PER FRAMING PLAN
SLOPE -SEE
ROOF SHEATHING
2 LAYERS OF
TYPE 15 FELT
FOOR RIDGE STRAP
ROOF ASPHALT SHINGLES
NOTES:
1. ROOF SLOPE-COMP SHINGLES (R905.2)
2. RIDGE (R802.3) NAILS (TABLE R602.3(1))
ROOF PLAN
SLOPE -SEE
ROOF SHEATHING
2 LAYERS OF
TYPE 15 FELT
ROOF ASPHALT
SHINGLES
NOTES:
1. ROOF SLOPE-COMP SHINGLES (R905.2)
ROOF PLAN
SELF-ADHERED FLEXIBLE
FLASHING, TYP.
(2) LAYERS OF GRADE D BLDG PAPER,
TYP. EXT. PLYWOOD SHEATHING.
7/8" EXTERIOR PLASTER OVER
METAL LATH
8" MIN. SAFF
8"
M
I
N
.
S
A
F
F
4"
M
I
N
.
GALV. SHEET METAL FLASHING.
PAINT TO MATCH EXT. TRIM.
26 GA. GALV. WEEP SCREED 2X RAFTER PER STRUCTURAL
DRAWINGS
1/2" CDX PLY SHEATHING W/8d @
6"/6"/12" O.C. (COMMON NAILS)
REFERENCE STRUCTURAL DRAWINGS.
2X BLKG.
B.N. 8D @ 6" O.C.
(8) 16D NAILS MIN.
NOTE:
1. 1 HR RATED WALL
WHERE NOTED, SEE
FLOOR PLAN
2. NO SOFFIT VENTS
ON 1 HR OVERHANG
1-HR RATED WALL PER WALL TYPES.
1/2" WOOD STR. PANEL,
REF. STRUC. DRAWINGS
(2) 2X4 TOP PLATE
1-HR RATED SOFFIT
7/8" EXTERIOR PLASTER ON METAL
LATH OVER (2) LAYERS BLDG PAPER
OVER 1/2" EXT. PLYWOOD SHEATHING
UPLIFT FRAMING CLIP PER TABLE R802.11
SIMPSON TIE PER STRUCTURAL
DRAWINGS
2X FASCIA W/ 2# 10X 3" LONG WOOD
SCREWS @ EACH RAFTER
EDGE NAIL
SHT. MTL. FLASHING
2 LAYERS OF 15# FELT
W/ 19" OVERLAP.
ROOF SHEATHING
ROOF ASPHALT SHINGLES
SELF-ADHERE FLEXIBLE
FLASHING AT ROOF
TRANSITION
(N) FLASHING TAPE
20 G.A. SHEET METAL
FLASHING WITH
INTEGRATED DRIP EDGE
7/8" CEMENT PLASTER
OVER MTL LATH OVER (2)
LAYERS OF GRADE D
BLDG PAPER, TYP.
8" S.A.F.F.
A35 @ 12" O.C.
(E) CEILING JOIST
CEILING GYP. BD.
5/8" TYPE X GYP. BD.
WOOD BLOCKING
S
E
A
L
A
N
T
1/
2
"
F
I
R
E
PACK BATT INSULATION
WITHIN CAVITY
ROOF UNDERLAYMENT
NOTE:
1. 1 HR RATED WALL
WHERE NOTED, SEE
FLOOR PLAN
2. NO SOFFIT VENTS ON
1 HR OVERHANG
ISSUED
DATE:
REVISIONS
DRAWINGS, SPECIFICATIONS AND OTHER VISUAL AIDS, AS
INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE
DRAFTER/DESIGNER WHETHER THE PROJECT FOR
WHICH THEY ARE MADE BE EXECUTED OR NOT, AND
THEY ARE NOT TO BE USED FOR ANY OTHER SITE THAN
THE ONE FOR WHICH THEY ARE PREPARED, EXCEPT BY
AGREEMENT IN WRITING.
NO
.
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
DRAFTER/DESIGNER:
LUIS N OROZCO
562.661.9281
LUIS.OROZCO.A@LIVE.COM
DATE:
04/24/25
A501
DETAILS - CONSTRUCTION
PR
O
P
E
R
T
Y
O
W
N
E
R
:
S
I
L
V
I
A
T
O
R
R
E
S
15
1
1
S
.
B
I
R
C
H
S
T
.
SA
N
T
A
A
N
A
,
C
A
9
0
7
2
7
GA
R
A
G
E
C
O
N
V
E
R
S
I
O
N
T
O
A
N
AC
C
E
S
S
O
R
Y
D
W
E
L
L
I
N
G
U
N
I
T
09/10/2024
Scale:3" = 1'-0"C3 DR - EXTERIOR DOOR HEAD
Scale:3" = 1'-0"C1 DR - EXTERIOR DOOR - THRESHOLD
Scale:1 1/2" = 1'-0"B1 RF - EAVE & VENT
Scale:3" = 1'-0"A1 EXT - WALL FOOTING - SOG
Scale:3" = 1'-0"D2 WD - WINDOW HEAD
Scale:3" = 1'-0"A2 EXT - WALL FOOTING - RAISED
Scale:3" = 1'-0"C2
DR - EXTERIOR DOOR -
THRESHOLD.W
Scale:3" = 1'-0"D1 WD - WINDOW SILL
NOT USED
Scale:3" = 1'-0"A3 EXT - WALL - CLADING
Scale:3" = 1'-0"F1 RF - T.O. RIDGE
NOT USED
Scale:3" = 1'-0"F2 RF - ROOF TO WALL
3
B
U
I
L
D
I
N
G
S
U
B
M
I
T
T
A
L
#
2
0
4
/
2
4
/
2
5
Scale:1 1/2" = 1'-0"B2 RF - RATED EAVE & VENT
NOT USED
Scale:3" = 1'-0"B3
EXT - WALL & ROOF FLUSH
TRANSITION
3
ACCESS PANEL -PUSH UP
INSULATION
DOUBLE 2X PER FRAMING
PLAN. SEE A3.02 FOR REF.
GYPSUM BOARD
TRIM
AIR-SEAL GASKET
6x CEILING JOIST
@ 16" O.C. MAX.
WALL PER WALL TYPES,
TYP.
5/8" GYP. BD. CEILING
SIMPSON U26 EA.
SIDE, TYP.
2X LEDGE W/ 3-16D NAILS @ EACH
STUD W/ 3-16 D NAIL @ EACH BLKG.
2X BLKG.
2X4 @ 16" O.C. STUD
WIRE MESH
6-MIL POLY OR 15LB. FELT,
LAP OVER MEMBRANE
TILE OVER LATEX-MODIFIED THINSET
(N) 4" SHOWER DRAIN,
2-PIECE CLAMPING
SOLID BLOCKING BETWEEN STUDS
EXTEND MEMBRANE 3" ABOVE CURB
MORTAR BED OR CEMENT
BACKER BOARD
2X WALL
MORTAR BED
40-MIL CPE SHOWER
PAN MEMBRANE
CRUSHED TILE AROUND
WEEP HOLES
LATEX-MODIFIED MORTAR
SLOPED 1/4" PER FT.
15 LB. FELT AND WIRE LATH
WOOD FLOOR SUB-BASE,
SEE STRUCT. FOR REF.
CURB
SEALANT WITH BACKER ROD.
ALUMINUM TRACK TO BE
INSTALLED PER MANF. SPECS.
BATHROOM GLASS ENCLOSURE. SEE
ENLARGE PLAN FOR SAFETY GLAZING
INFORMATION.
2
1
3 3
4
5
6
1. 1/2" SISALKRAFT FLASHING
OR EQUIVALENT
2. INSTALL SILL FLASHING
FASTEN TOP EDGE ONLY
3. INSTALL SIDE FLASHING
LAP OVER SILL FLASHING
4. INSTALL FRAME WITH NAILING
FLANGE ON CONT. SEALANT BED
5. INSTALL HEAD FLASHING ON
CONT. SEALANT BED OVER
NAILING FLANGE
6. INSTALL BUILDING FELT UNDER
SILL FLASHING AND OVER
SIDE AND HEAD FLASHING
BEST PRACTICES FOR FUTURE PHOTOVOLTAIC SYSTEM INSTALLATION
ELEC. SERVICE PANEL SHALL HAVE
RESERVED SPACES TO ALLOW FOR
THE INSTALLATION OF DOUBLE
POLE CIRCUIT BREAKERS FOR THE
FUTURE INSTALLATION OF:
1.SOLAR ELECTRIC. (CEnC 110.10 (b)B 4(e))
2.ENERGY STORAGE
SYSTEM (CEnC 150.0(s))
3.HEAT PUMP SPACE HEATER(CEnC 150.0(t))
4.ELECT. COOKTOP (CEnC 150.0(u))
5.ELECT. CLOTHES DRYER (CEnC 150.0(v))
RESERVE 36"X36" AREA
FOR INVERTER, METER
AND DISCONNECT
3/4" NON-FLEXIBLE METAL
CONDUIT (MIN.) WITH PULL
STRING TERMINATED IN 4"
SQUARE BOX FOR DC
CONDUCTORS APPROX. 36"
OFF THE FINISHED FLOOR
AND LABELED "RESERVED
FOR SOLAR"
ELECTRIC PANEL
MAIN
FINISHED FLOOR
3
6
"
3
6
"
36"
SEE FLOOR PLAN
0'
-
3
"
T
Y
P
.
1'-0" TYP.EQ
EQ
0'
-
1
1
/
2
"
CONCRETE HOUSEKEEPING PAD
CHAMFER ALL OUTSIDE CORNERS
CONSTRUCTION NOTES:
1. PAD DIMENSIONS AND ANCHOR BOLT SIZES TO SUIT EQUIPMENT.
REFERENCE EQUIPMENT MANUFACTURER SPECS FOR INSTALLATION
REQUIREMENTS.
DESIGN NOTES:
1. CONSULT WITH EQUIPMENT CUTSHEET TO DETERMINE IF A THICKENED
FLOOR SLAB UNDER BASED IS REQUIRED.
2. SLAB SURFACE PREPARATION FOR PAD DETERMINED BY WHETHER NEW
OR EXISTING.
SLAB SURFACE SHALL BE ROUGHENED IN
PREPARATION FOR CONCRETE PAD.
W.W.F. 6X6 -W4XW4
#4 @12" O.C. ALONG
PERIMETER OF PAD
AL
L
A
R
O
U
N
D
0'
-
1
"
C
L
E
A
R
(E) FINISH FLOOR0'
-
0
1
/
2
"
0' - 0 1/2"
EPOXY DOWEL INTO
CONC. SLAB
4" MIN.
EXTEND EDGE OF PAD
4" MIN. BEYOND
EQUIP. FRAME, TYP.
TOP
LANDING
BOTTOM
LANDING
NOTE:
FOR TREAD AND RISER DIMENSION REFER TO PLANS AND SECTIONS.
STAIRS, REISER AND LANDINGS SHALL BE COORDIANTED BY CONTRACTOR.
TW = TREAD WIDTH
1-1/4 MAX
TW
12" MIN
12" MIN
TW + 1236
"
T
Y
P
TO
F
F
36
"
T
Y
P
.
TOP & BOTTOM TYP
1-1/2" OD HANDRAIL
WITH RADIUSED RETURNS
TO WALL EA END. HANDRAIL
MATERIAL TBD.
A502
C3
NOTE:
THE BOTTOM OF HANDRAIL GRIPPING SURFACES SHALL NOT BE OBSTRUCTED
FOR MORE THAN 20% OF THEIR LENGTH.
FINISH WALL
1-1/2" ∅HANDRAIL
1/
8
"
C
L
E
A
R
1 1/2"
1 1/2" MIN
1 1/2"
1 1/2" MIN
1
1
/
2
"
U.
N
.
O
.
36
"
M
I
N
.
U.
N
.
O
.
36
"
M
I
N
.
WASHER DRYER
12
"
M
I
N
.
VERTICAL (VER.) VENT
BACK DRAFT DAMPER (BDD).
SEE FLOOR PLAN FOR VENT
DIRECTION / ORIENTATION.
HORIZONTAL (HRZ.) VENT
DIRECT TO EXTERIOR (14
FEET MAX). SEE FLOOR PLAN
FOR VENT DIRECTION /
ORIENTATION.
VE
R
.
V
E
N
T
HRZ. VENT
DRYER VENT INLET
GFI QUAD OUTLET
HOT & COLD WATER
SUPPLY
DRAIN
GAS POINT OF
CONNECTION
18
"
T
Y
P
.
CLOTHES DRYERS -DOMESTIC MOISTURE EXHAUST DUCTS PER CMC SECTION 504
• DUCT SHALL TERMINATE ON THE OUTSIDE OF BUILDING AND BE EQUIPPED WITH
BACK-DRAFT DAMPER.
• NO SCREENS SHALL BE INSTALLED AT DUCT TERMINATION
• DUCT SHALL NOT BE CONNECTED BY SHEET METAL SCREWS OR OTHER
OBSTRUCTIVE FASTENERS.
• DUCT SHALL NOT BE CONNECTED TO GAS VENT CONNECTOR, GAS VENT, OR
CHIMNEY AND SHALL ONLY SERVE CLOTHS DRYERS.
• DUCTS UNDER POSITIVE PRESSURE SHALL NOT EXTEND INTO OR THROUGH DUCT OR
PLENUMS.
• A FLEXIBLE DUCT CANNOT EXTEND MORE THAN 6 FT AND CANNOT BE CONCEALED.
• VENTS SHALL BE INSTALLED TO EXTEND AT MIN. 12" ABOVE FINISHED ROOF
SURFACE.
•
DOMESTIC CLOTHES DRYERS
WHEN A COMPARTMENT OR SPACE FOR DOMESTIC TYPE 1 CLOTHS DRYER IS PROVIDED,
THE FOLLOWING RESTRICTIONS APPLY:
• MINIMUM 4-INCH DIAMETER MOISTURE EXHAUST DUCT APPROVED MATERIAL SHALL
BE INSTALLED.
• DUCTS SHALL BE INSULATED THROUGH ATTIC ND CRAWL SPACE WITH 1 3/4" POUND
FIBERGLASS DUCT WRAP.
• DOMESTIC CLOTHES DRYER VENTS SHALL BE MADE OF METAL AND HAVE SMOOTH
INTERIOR SURFACE.
• TRANSITION DUCTS USE TO CONNECT THE DRYER TO THE EXHAUST DUCT SHALL BE
LISTED AND LABELED IN ACCORDANCE WITH UL 2158A.
LENGTH LIMITATION
• UNLESS OTHERWISE PERMITTED OR REQUIRED BY THE DRYER MANUFACTURER'S
INSTALLATION INSTRUCTIONS, AND APPROVED BY THE BUILDING OFFICIAL, DOMESTIC
DRYER MOISTURE EXHAUST DUCTS SHALL NOT EXCEED A TOTAL COMBINED
HORIZONTAL AND VERTICAL LENGTH OF 14 FT, INCLUDING TWO 90-DEGREE ELBOWS.
• TWO FEET SHALL BE DEDUCTED FOR EACH 90-DEGREE ELBOW IN EXCESS OF TWO.
EXCEPTION: WHERE AN EXHAUST DUCT POWER VENTILATOR, IN ACCORDANCE WITH
SECTION 504.4.2.3, I USED, THE MAXIMUM LENGTH OF THE DRYER EXHAUST DUCT SHALL BE
PERMITTED TO BE IN ACCORDANCE WITH THE DRYER EXHAUST DUCT POWER VENTILATOR
MANUFACTURER'S INSTALLATIONS INSTRUCTIONS.
EXHAUST DUCT POWER VENTILATORS
• DRYER EXHAUST DUCT POWER VENTILATORS FOR SINGLE RESIDENTIAL CLOTHES
DRYERS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 705 AND
INSTALLED IN ACCORDANCE WITH THE MANUFACTURE'S INSTALLATION
INSTRUCTIONS.
TERMINATION OF ENVIRONMENTAL AIR DUCTS
• DUCT SHALL TERMINATE A MINIMUM OF 3 FT FROM PROPERTY LINE AND 3 FT FROM
OPENINGS INTO THE BUILDING.
PROVISIONS FOR MAKEUP AIR
• WHERE A CLOSET IS DESIGNED FOR THE INSTALLATION OF A CLOTHES DRYER, AN
OPENING OF NO LESS THAN 100 SQUARE INCHES FOR MAKEUP AIR SHALL BE
PROVIDED IN THE DOOR OR BY OTHER APPROVED MEANS.
INTERIOR ELEVATION
ISSUED
DATE:
REVISIONS
DRAWINGS, SPECIFICATIONS AND OTHER VISUAL AIDS, AS
INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE
DRAFTER/DESIGNER WHETHER THE PROJECT FOR
WHICH THEY ARE MADE BE EXECUTED OR NOT, AND
THEY ARE NOT TO BE USED FOR ANY OTHER SITE THAN
THE ONE FOR WHICH THEY ARE PREPARED, EXCEPT BY
AGREEMENT IN WRITING.
NO
.
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
DRAFTER/DESIGNER:
LUIS N OROZCO
562.661.9281
LUIS.OROZCO.A@LIVE.COM
DATE:
A502
DETAILS - CONSTRUCTION
PR
O
P
E
R
T
Y
O
W
N
E
R
:
S
I
L
V
I
A
T
O
R
R
E
S
15
1
1
S
.
B
I
R
C
H
S
T
.
SA
N
T
A
A
N
A
,
C
A
9
0
7
2
7
GA
R
A
G
E
C
O
N
V
E
R
S
I
O
N
T
O
A
N
AC
C
E
S
S
O
R
Y
D
W
E
L
L
I
N
G
U
N
I
T
09/10/2024
Scale:3" = 1'-0"A2 INT - ATTIC ACCESS PANEL
Scale:1 1/2" = 1'-0"A3
INT - WOOD FRAME TYPICAL
CEILING
Scale:3" = 1'-0"B1 INT - SHOWER PAN - WOOD FLOORS
Scale:3" = 1'-0"B3 WD - PERIMETER FLASHING
Scale:3" = 1'-0"B2 EXT - ELEC. SVC PANEL- FUTURE PV
Scale:3" = 1'-0"C1 EXT - HVAC HOUSEKEEPING PAD
Scale:1/4" = 1'-0"C2 INT - STAIR RAILING
Scale:1 1/2" = 1'-0"C3 INT - RAILING REQUIREMENT
Scale:3" = 1'-0"D1 INT - DOMESTIC CLOTHES DRYER
NOT USED
NOT USED
ISSUED
DATE:
REVISIONS
DRAWINGS, SPECIFICATIONS AND OTHER VISUAL AIDS, AS
INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE
DRAFTER/DESIGNER WHETHER THE PROJECT FOR
WHICH THEY ARE MADE BE EXECUTED OR NOT, AND
THEY ARE NOT TO BE USED FOR ANY OTHER SITE THAN
THE ONE FOR WHICH THEY ARE PREPARED, EXCEPT BY
AGREEMENT IN WRITING.
NO
.
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
DRAFTER/DESIGNER:
LUIS N OROZCO
562.661.9281
LUIS.OROZCO.A@LIVE.COM
DATE:
A503
DETAILS - TYP.
CONSTRUCTION
PR
O
P
E
R
T
Y
O
W
N
E
R
:
S
I
L
V
I
A
T
O
R
R
E
S
15
1
1
S
.
B
I
R
C
H
S
T
.
SA
N
T
A
A
N
A
,
C
A
9
0
7
2
7
GA
R
A
G
E
C
O
N
V
E
R
S
I
O
N
T
O
A
N
AC
C
E
S
S
O
R
Y
D
W
E
L
L
I
N
G
U
N
I
T
09/10/2024
PIPE SCHEDULE
PIPE
SOIL
WASTE & VENT
WATER AFF
WATER BEL FLR
MATERIAL
DWV ABS
DWV ABS
TYPE "L" COPPER
TYPE "K" COOPER
MATERIAL FINISH LEGEND
FLOOR
F1 ENGINEERED HARDWOOD OVER
SCREED ADHESIVE
F2 SUBWAY TILE
F3 CONCRETE FLOOR -BROOM
FINISH
F4 CERAMIC TILE
BASE
B1 HARD WOOD BASE
B2 SUBWAY TILE
B3 CERAMIC TILE
WALL
W1 GYPSUM BOARD
W2 TYP "X" GYPSUM BOARD
W3 CEMENTITIOUS BACKER
BOARD
W4 CERAMIC TILE
CEILING
C1 HARD LID
C2 HARD LID W/ TYPE "X" GYP
C3 HARD LID -MOISTURE
RESISTANT GYP. BD.
FINISH
PT1 PAINT -COLOR TBD.
PT2 PAINT -SEMI-GLOSS.
SMOOTH&EASILY
WASHABLE
TL1 SUBWAY TILE
DOOR TYPE
A1 -INT
POCKET
A3 - INT
SEE SCHEDULE
SE
E
S
C
H
E
D
U
L
E
A2 - INT
FRAMELESS
SEE SCHEDULE
SE
E
S
C
H
E
D
U
L
E
A4 - INT
SEE SCHEDULE
SE
E
S
C
H
E
D
U
L
E
SE
E
S
C
H
E
D
U
L
E
SEE SCHEDULE
DOOR HARDWARE
TBD
GR - EXT
SE
E
S
C
H
E
D
U
L
E
SEE SCHEDULESEE SCHEDULE
SE
E
S
C
H
E
D
U
L
E
B2 - EXT
B1 - EXT
SEE SCHEDULE
SE
E
S
C
H
E
D
U
L
E
TRI - EXT
SE
E
S
C
H
E
D
U
L
E
SEE SCHEDULE
A5 - INT VENTED
SEE SCHEDULE
SE
E
S
C
H
E
D
U
L
E
MIN. 100 SQ.IN. OPENING
SEE SCHEDULE
SE
E
S
C
H
E
D
U
L
E
B3 - EXT
WINDOW TYPEWINDOW TYPE
WA
SEE SCHEDULE
SE
E
S
C
H
E
D
U
L
E
SE
E
E
X
T
.
E
L
E
V
SINGLE-HUNG CASEMENT
WD
SLIDER
SEE SCHEDULE
SE
E
E
X
T
.
E
L
E
V
WC
FIXED
SEE SCHEDULE
SE
E
E
X
T
.
E
L
E
V
EGRESS WINDOWS:
SYMBOL (*) 1. 20" MIN. CLEAR WIDTH
2. 24" MIN. CLEAR HEIGHT
3. 5.7 SF. MIN. OPERABLE AREA
NOTES:
A. EMERGENCY ESCAPE / EXIT WINDOW PER CBC 310.4
B. SIZES ARE TAKEN FROM DATA SUPPLIED BY WINDOW MANUFACTURER, HOWEVER THESE ARE GENERAL DIMENSIONS. IT
IS THE OWNER'S RESPONSIBILITY TO VERIFY THAT THE ACTUAL WINDOWS INSTALLED MEET THE MINIMUM EGRESS
REQUIREMENTS.
C. TEMPERED GLAZING SHALL BE INCLOMPLIANCE WITH ANSI Z97. PROVIDE FULL-LENGTH SIDE AND DOOR CLEAR SEAL
STRIP BETWEEN WALL AND GLASS DOOR OR FIXED PANEL.
D. FIRE-RATED WINDOWS SHALL HAVE FIRE RATING OF 3/4 HR W/ A FIRE RATED GLAZING NOTED WITH MARKING D/H/45 PER
TABLES 716.1(1) & 716.1(2)
E.THE NFRC TEMPORARY LABEL DISPLAYED ON WINDOWS MUST REMAIN ON THE UNIT UNTIL FINAL INSPECTION HAS BEEN
COMPLETED.
WE
SAFETY GLAZING TO BE PROVIDED AS REQ. WHERE:
1. SAFETY GLAZING TO BE PROVIDED IN ACCORDANCE WITH R308.4.5
2. SAFETY GLAZING WITH BOTTOM LESS THAN 18" ABOVE FLOOR AND AREA GRATER THAN 9 SQUARE FEET AND TOP EDGE
OVER 36" ABOVE FLOOR.
3. INDOORS.
4. WITHIN 24" ARC OF EITHER SIDE OF DOORS AND WITHIN 60" OF FLOOR (CBC 2406.3).
5. LESS THAN 5" ABOVE TUB/SHOWER FLOOR.
6. AT STAIRWAY LANDING OR WITHIN 5' OF TOP AND BOTTOM LANDING WHEN BOTTOM EDGE IS LESS THAN 60" ABOVE FLOOR .
7. LIGHTS WITHIN 40" OF A REQUIRED DOOR LOCK SHALL BE FULLY TEMPERED GLASS, APPROVED BURGLARY RESISTANT
MATERIAL, OR GUARDED BY METAL BARS, SCREENS OR GRILLES IN AN APPROVED MANNER [IMC 11-3 (15)] [CBC 2406.4]
SLIDER
FIRE-RATED
WG
SEE SCHEDULE
SE
E
E
X
T
.
E
L
E
V
SEE SCHEDULE
SE
E
S
C
H
E
D
U
L
E
SE
E
E
X
T
.
E
L
E
V
AWNING
WF
SEE SCHEDULE
SE
E
S
C
H
E
D
U
L
E
SE
E
E
X
T
.
E
L
E
V
WB
SEE SCHEDULE
SE
E
S
C
H
E
D
U
L
E
SE
E
E
X
T
.
E
L
E
V
DOUBLE-HUNG
DOOR SCHEDULE
DOOR
NUMBER DOOR TYPE WIDTH HEIGHT THK DOOR MAT. FINISH COMMENTS
101A B2 3' - 0" 7' - 0" 1 3/8" SOLID CORE WOOD STAIN
101B A3 2' - 4" 6' - 8" 1 3/8" HOLLOW CORE MDF PAINT
101C A3 2' - 8" 6' - 8" 1 3/8" HOLLOW CORE MDF PAINT
101D A3 2' - 8" 6' - 8" 1 3/8" HOLLOW CORE MDF PAINT
101E B3 2' - 10" 6' - 8" 1 3/8" SOLID CORE WOOD STAIN
WINDOW SCHEDULE
WINDOW
NUMBER
WINDOW
TYPE WIDTH HEIGHT FRAME
TYPE U-FACTOR SHGC GLAZING
W1 W-62 4' - 0" 4' - 0" VINYL 0.3 0.23
W2 W-65 2' - 5" 1' - 10 1/2" VINYL 0.3 0.23 FRONSTED
W3 W-63 3' - 0" 3' - 0" VINYL 0.3 0.23
W4 W-63 3' - 0" 3' - 0" VINYL 0.3 0.23
W5 W-64 2' - 11" 2' - 5 1/2" VINYL 0.3 0.23
ROOM FINISH
ROOM NAME
ROOM
NUMBER
FLOOR
FINISH
BASE
FINISH
NORTH WALL EAST WALL SOUTH WALL WEST WALL CEILING
COMMENTSN-MTL N-FN E-MTL E-FN S-MTL S-FN W-MTL W-FN MTL FN
DINNING 101 F2 B1 W1 PT1 W1 PT1 W1 PT1 W1 PT1 C1 PT1
LIVING 102 F2 B1 W1 PT1 W1 PT1 W1 PT1 W1 PT1 C1 PT1
KITCHEN 103 F2 B1 W1 PT1 W1 PT1 W1 PT1 W1 PT1 C1 PT1
MASTER
BEDROOM
104 F2 B1 W1 PT1 W1 PT1 W1 PT1 W1 PT1 C1 PT1
BEDROOM #1 105 F2 B1 W1 PT1 W1 PT1 W1 PT1 W1 PT1 C1 PT1
BEDROOM #2 106 F2 B1 W1 PT1 W1 PT1 W1 PT1 W1 PT1 C1 PT1
M. BATH 107 F3 B3 W2/W3 PT2 W2/W3 PT2 W2/W3 PT2 W2/W3 PT2 C3 PT2
BATH 108 F3 B3 W2/W3 PT2 W2/W3 PT2 W2/W3 PT2 W2/W3 PT2 C3 PT2
HALL 109 F2 B1 W1 PT1 W1 PT1 W1 PT1 W1 PT1 C1 PT1
ISSUED
DATE:
REVISIONS
DRAWINGS, SPECIFICATIONS AND OTHER VISUAL AIDS, AS
INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE
DRAFTER/DESIGNER WHETHER THE PROJECT FOR
WHICH THEY ARE MADE BE EXECUTED OR NOT, AND
THEY ARE NOT TO BE USED FOR ANY OTHER SITE THAN
THE ONE FOR WHICH THEY ARE PREPARED, EXCEPT BY
AGREEMENT IN WRITING.
NO
.
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
DRAFTER/DESIGNER:
LUIS N OROZCO
562.661.9281
LUIS.OROZCO.A@LIVE.COM
DATE:
A601
SCHEDULES
PR
O
P
E
R
T
Y
O
W
N
E
R
:
S
I
L
V
I
A
T
O
R
R
E
S
15
1
1
S
.
B
I
R
C
H
S
T
.
SA
N
T
A
A
N
A
,
C
A
9
0
7
2
7
GA
R
A
G
E
C
O
N
V
E
R
S
I
O
N
T
O
A
N
AC
C
E
S
S
O
R
Y
D
W
E
L
L
I
N
G
U
N
I
T
09/10/2024
NOTES:
TEMPERED GLASS IN COMPLIANCE WITH ANSI Z97. PROVIDE FULL-LENGTH SIDE AND DOOR CLEAR SEAL
STRIP BETWEEN WALL AND GLASS DOOR OR FIXED PANEL
NOTES:
1. CONTACT PANORAMIC FOLDING DOORS FOR PRODUCT SPECIFIC INFORMATION.
REP. KORNEL GALAMBOS 424-299-7111 (KORNEL@PANORAMICDOORS.COM).
2. PROVIDE BOTTOM-HUNG THERMALLY BROKEN SYSTEM -VINYL DOOR FRAME
U VALUE = 0.29
SHGC = 0.18
3. PROVIDE UPSTEP WATERPROOF TRACK
DISTANCE TO PUBLIC TRANSIT STOP
SUBJECT
SITE
.2 MILES TO BUS STOP.
@EDINGER/ VAN NESS
03/28/2025
03/28/2025
03/28/2025
03/28/2025
NON-LOAD BEARING WALLS
NON-LOAD BEARING WALLS
NON-LOAD BEARING WALLS
ISSUED
DATE:
REVISIONS
DRAWINGS, SPECIFICATIONS AND OTHER VISUAL AIDS, AS
INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE
DRAFTER/DESIGNER WHETHER THE PROJECT FOR
WHICH THEY ARE MADE BE EXECUTED OR NOT, AND
THEY ARE NOT TO BE USED FOR ANY OTHER SITE THAN
THE ONE FOR WHICH THEY ARE PREPARED, EXCEPT BY
AGREEMENT IN WRITING.
NO
.
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
DRAFTER/DESIGNER:
LUIS N OROZCO
562.661.9281
LUIS.OROZCO.A@LIVE.COM
DATE:
11/19/2024
G104
CALGREEN RESIDENTIAL
MANDATORY MEASURES
PR
O
P
E
R
T
Y
O
W
N
E
R
:
S
I
L
V
I
A
T
O
R
R
E
S
15
1
1
S
.
B
I
R
C
H
S
T
.
SA
N
T
A
A
N
A
,
C
A
9
0
7
2
7
GA
R
A
G
E
C
O
N
V
E
R
S
I
O
N
T
O
A
N
AC
C
E
S
S
O
R
Y
D
W
E
L
L
I
N
G
U
N
I
T
09/10/2024
2
B
U
I
L
D
I
N
G
S
U
B
M
I
T
T
A
L
1
1
/
1
9
/
2
0
2
4
GC
GC
GC
X
X
X
X
X
X
X
X
X
GC
GC
GC
GC
GC
GC
GC
GC
GC
GC
ISSUED
DATE:
REVISIONS
DRAWINGS, SPECIFICATIONS AND OTHER VISUAL AIDS, AS
INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE
DRAFTER/DESIGNER WHETHER THE PROJECT FOR
WHICH THEY ARE MADE BE EXECUTED OR NOT, AND
THEY ARE NOT TO BE USED FOR ANY OTHER SITE THAN
THE ONE FOR WHICH THEY ARE PREPARED, EXCEPT BY
AGREEMENT IN WRITING.
NO
.
D
E
S
C
R
I
P
T
I
O
N
D
A
T
E
DRAFTER/DESIGNER:
LUIS N OROZCO
562.661.9281
LUIS.OROZCO.A@LIVE.COM
DATE:
11/19/2024
G105
CALGREEN RESIDENTIAL
MANDATORY MEASURES
PR
O
P
E
R
T
Y
O
W
N
E
R
:
S
I
L
V
I
A
T
O
R
R
E
S
15
1
1
S
.
B
I
R
C
H
S
T
.
SA
N
T
A
A
N
A
,
C
A
9
0
7
2
7
GA
R
A
G
E
C
O
N
V
E
R
S
I
O
N
T
O
A
N
AC
C
E
S
S
O
R
Y
D
W
E
L
L
I
N
G
U
N
I
T
09/10/2024
2
B
U
I
L
D
I
N
G
S
U
B
M
I
T
T
A
L
1
1
/
1
9
/
2
0
2
4
GC
X
GC
GC
GC
GC
GC
X
X
X
GC
X
X
GC
ENGX
GC
GC
GC
GC
GC
GC
P.O. BOX 470011
LOS ANGELES, CA 90047
(323) 955-9827
EMAIL:LRGDESIGNS914@GMAIL.COM
WEBSITE: LRGENERGYDESIGN.COM
SHEET
OF SHEETS
T-1
SCALE
11/8/2024
DATE
PROJECT:ADU ADDITION
SITE ADDRESS: 1513 S. BIRCH STREET
SANTA ANA, CA 90727
OWNER:
REVISION / DATE
AD
U
-
GA
R
A
G
E
C
15
1
1
S
.
B
I
R
C
H
S
T
.
,
S
A
N
T
A
A
N
A
,
C
A
9
0
7
2
7
-
SF
R
15
1
3
S
.
B
I
R
C
H
S
T
.
,
S
A
N
T
A
A
N
A
,
C
A
9
0
7
2
7
-
AD
U
P.O. BOX 470011
LOS ANGELES, CA 90047
(323) 955-9827
EMAIL:LRGDESIGNS914@GMAIL.COM
WEBSITE: LRGENERGYDESIGN.COM
SHEET
OF SHEETS
T-2
SCALE
11/8/2024
DATE
PROJECT:ADU ADDITION
SITE ADDRESS: 1513 S. BIRCH STREET
SANTA ANA, CA 90727
OWNER:
REVISION / DATE
AD
U
-
GA
R
A
G
E
C
15
1
1
S
.
B
I
R
C
H
S
T
.
,
S
A
N
T
A
A
N
A
,
C
A
9
0
7
2
7
-
SF
R
15
1
3
S
.
B
I
R
C
H
S
T
.
,
S
A
N
T
A
A
N
A
,
C
A
9
0
7
2
7
-
AD
U
P.O. BOX 470011
LOS ANGELES, CA 90047
(323) 955-9827
EMAIL:LRGDESIGNS914@GMAIL.COM
WEBSITE: LRGENERGYDESIGN.COM
1.Compliance information The builder shall leave in the building, copies of the completed, signed and submitted
compliance documents for the building owner at occupancy. For low-rise residential buildings, such information
shall, at a minimum, include copies of all Certificate of Compliance, Certificate of Installation, and Certificate of
Verification documentation submitted. . [10-103(b)1]
2.Operating information. The builder shall provide the building owner at occupancy, operating information for all
applicable features, materials, components, and mechanical devices installed in the building. Operating
information shall include instructions on how to operate the features, materials, components, and mechanical
devices correctly and efficiently. The instructions shall be consistent with specifications set forth by the Executive
Director. For residential buildings, such information shall be contained in a folder or manual which provides all
Certificate of Compliance, Certificate of Installation, and Certificate of Verification documentations. This operating
information shall be in paper or electronic format. [10-103(b)2]
3.Maintenance information. The builder shall provide to the building owner at occupancy, maintenance information
for all features, materials, components, and manufactured devices that require routine maintenance for efficient
operation. Required routine maintenance actions shall be clearly stated and incorporated on a readily accessible
label. The label may be limited to identifying, by title and/or publication number, the operation and maintenance
manual for that particular model and type of feature, material, component or manufactured device. [10-103(b)3]
4.Ventilation information. The builder shall provide to the building owner at occupancy, a description of the quantities
of outdoor air that the ventilation system(s) are designed to provide to the building’s conditioned space, and
instructions for proper operation and maintenance of the ventilation system. [10-103(b)4]
5. All systems, equipment, appliances and building components shall comply with the applicable manufacturing,
construction, and installation provisions of Sections 110.0 through 110.11 for newly constructed buildings.
6. Any appliance regulated by the Appliance Efficiency Regulations, Title 20 California Code of Regulations, Section
1601 et seq., may be installed only if the appliance fully complies with Section 1608(a) of those regulations.
[110.1(a)]
7. Service water-heating systems shall be equipped with automatic temperature controls capable of adjustment from
the lowest to the highest acceptable temperature settings for the intended use as listed in Table 3, Chapter 50 of the
ASHRAE Handbook, HVAC Applications Volume. [110.3(a)1]
8. On systems that have a total capacity greater than 167,000 Btu/hr, outlets that require higher than service water
temperatures as listed in the ASHRAE Handbook, Applications Volume, shall have separate remote heaters, heat
exchangers, or boosters to supply the outlet with the higher temperature. [110.3(c)1]
9. Service hot water systems with circulating pumps or with electrical heat trace systems shall be capable of
automatically turning off the system. [110.3(c)2]
10. Controls for service water-heating systems shall limit the outlet temperature at public lavatories to 110°F.
[110.3(c)3]
11. Unfired service water-heater storage tanks and backup tanks for solar water-heating systems shall have: a.
External insulation with an installed R-value of at least R-12, or b. Internal and external insulation with a combined R-
value of at least R-16, or c. The heat loss of the tank surface based on an 80°F water-air temperature difference
shall be less than 6.5 Btu/hr per square foot. [110.3 (c)4]
12. For Nonresidential, high-rise residential, and hotel/motel buildings, space conditioning systems shall meet the
efficiency standards specified Section 120.2.
13. Continuously burning pilot light shall be prohibited for the following natural gas system or equipment listed below:
[110.5] a. Fan-type central furnaces b. Household cooking appliances, except for household cooking appliances
without an electrical supply voltage connection and in which each pilot consumes less than 150 Btu/hr c. Pool
heaters d. Spa heaters
14. Any pool or spa heating system or equipment shall: [110.4] a. A thermal efficiency that complies with the
Appliance Efficiency Regulations b. Have a readily accessible on-off switch, mounted on the outside of the heater
that allows shutting off the heater without adjusting the thermostat setting. c. Not utilize electric resistance heating. d.
Have a cover for outdoor pools or spas that have a heat pump or gas heater. e. Have a permanent, easily readable,
and weatherproof instruction card that gives instructions for the energy efficient operation of the pool or spa heater
and for the proper care of pool or spa water when a cover is used. f. Have at least 36 inches of pipe installed
between the filter and heater or dedicated suction and return lines, or built-in or built-up connections shall be installed
to allow for the future addition of solar heating equipment. g. Have directional inlets for the pool or spa that
adequately mix the pool water. h. A time switch or similar control mechanism shall be installed as part of a pool water
circulation control system that will allow all pumps to be set or programmed to run only during the off-peak electric
demand period and for the minimum time necessary to maintain the water in the condition required by applicable
public health standards.
15. Manufactured fenestration products and exterior doors shall have air infiltration rates not exceeding 0.3 cfm/ft2 of
window area, 0.3 cfm/ft2 of residential door area, 0.3 cfm/ft2 of nonresidential single door area, and 1.0 cfm/ft2 of
nonresidential double door area. [110.6(a)1]
16. Fenestration products shall be rated in accordance with NFRC 100 for U-factor, NFRC 200 for SHGC, and VT or
use the applicable default value. Fenestration products shall have a temporary label for manufactured fenestration
products or a label certificate when the Component Modeling Approach is used and for site-built fenestration meeting
the requirements of Section 10-111(a)1. [110.6(a)2, 110.6(a)3, 110.6(a)4, 110.6(a)5]
17. Field-fabricated fenestration products and exterior doors, other than unframed glass doors and fire doors, shall
be caulked between the fenestration products or exterior door and the building, and shall be weatherstripped.
[110.6(b)]
18. Joints, penetrations and other openings in the building envelope that are potential sources of air leakage shall be
caulked, gasketed, weather stripped, or otherwise sealed to limit infiltration and exfiltration. [110.7]
19. Insulation shall be certified by Department of Consumer Affairs, Bureau of Home Furnishing and Thermal
Insulation that the insulation conductive thermal performance is approved pursuant to the California Code of
Regulations, Title 24, Part 12, Chapter 12-13, Article 3, “Standards for Insulating Material.” [110.8(a)]
20. Urea formaldehyde foam insulation may only be used in exterior side walls, and requires a four-mil-thick plastic
polyethylene vapor barrier between the urea formaldehyde foam insulation and the interior space in all applications.
[110.8(b)]
21. Insulating material shall be installed in compliance with the flame spread rating and smoke density requirements
of the CBC. [110.8(c)]
22. Insulation installed on an existing space conditioning duct, it shall comply with Section 604.0 of the CMC.
[110.8(d)3]
23. External insulation installed on an existing unfired water storage tank or on an existing back-up tank for a solar
water-heating system, it shall have an R-value of at least R-12, or the heat loss of the tank surface based on an 80
EF water-air temperature difference shall be less than 6.5 Btu per hour per square foot. . [110.8(d)2]
TITLE 24 NOTES TITLE 24 NOTES
E. Residential Notes:
1. A masonry or factory-built fireplace shall have the following: [150.0(e)1] a. Closeable metal or glass doors
covering the entire opening of the firebox; b. A combustion air intake to draw air from the outside of the building
directly into the firebox, which is at least six square inches in area and is equipped with a readily accessible,
operable, and tight-fitting damper or combustion-air control device (Exception: An outside combustion-air intake is
not required if the fireplace will be installed over concrete slab flooring and the fireplace will not be located on an
exterior wall.); and c. A flue damper with a readily accessible control. [150.0 (e)C]
2. Heating or cooling systems shall be equipped with a setback thermostat that meet the requirements of Section
110.2(c). [150.0(i)]
3. Gas or propane water heaters shall have: [150.0(n)] a. A 120V electrical receptacle that is within 3 feet from the
water heater. b. A Category III or IV vent, or a Type B vent with straight pipe. c. Condensate drain that is no more
than 2 inches higher than the base. d. A gas supply line with a capacity of at least 200,000 Btu/hr
4. All pumps and pump motors installed shall be listed in the Commission’s directory of certified equipment and
shall comply with the Appliance Efficiency Regulations. [150.0(p)1.A]
5. The minimum installed weight per square foot of any loose-fill insulation shall conform with the insulation
manufacturer's labeled R-value. [150.0 (b)]
6. The minimum depth of concrete-slab floor perimeter insulation shall be 16 inches or the depth of the footing of
the building, whichever is less. [150.1(c)(1)(D)]
7. The crawl space shall be covered with a vapor retarder over the entire floor. [150.1(c)1.D]
8. Insulations are required for: [150.0(j)2.A] a. All hot water pipes from the heating source to the kitchen fixtures.
b. All piping with a nominal diameter of 3/4 inch or larger. c. The first 5 feet (1.5 meters) of hot and cold water pipes
from the storage tank. d. All piping associated with a domestic hot water recirculation system. e. Piping from the
heating source to storage tank or between tanks. f. Piping buried below grade.
9. Insulation shall be provided for water heaters as follows: a. Unfired hot water tanks, such as storage tanks and
backup storage tanks for solar water-heating systems, shall be externally wrapped with insulation having an
installed thermal resistance of R-12 or greater or have internal insulation of at least R-16 and a label on the
exterior of the tank showing the insulation R-value. [150.0 (j)1]
10. Lighting [150.0(k)] a. Installed luminaires shall be classified as high-efficacy in accordance with TABLE 150.0-
A. b. Exhaust fans shall be switched separately from lighting systems. c. Luminaries shall be switched with readily
accessible controls that permit the luminaries to be manually switched ON and OFF. d. Lighting installed in
attached and detached garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces
shall be controlled by vacancy sensors. e. Dimmers or vacancy sensors shall control all luminaires required to
have light sources compliant with Reference Joint Appendix JA8. EXCEPTION 1: Luminaires in closets less than
70 square feet. EXCEPTION 2: Luminaires in hallways. f. A. In a low-rise multifamily residential building where the
total interior common area in a single building equals 20 percent or less of the floor area, permanently installed
lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant
sensor. g. In a low-rise multifamily residential building where the total interior common area in a single building
equals more than 20 percent of the floor area, permanently installed lighting in that building shall: i) Comply with
the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6 and 141.0; and ii) Lighting installed in corridors
and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50
percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
SHEET
OF SHEETS
T-3
SCALE
11/8/2024
DATE
PROJECT:ADU ADDITION
SITE ADDRESS: 1513 S. BIRCH STREET
SANTA ANA, CA 90727
OWNER:
REVISION / DATE
AD
U
-
GA
R
A
G
E
C
15
1
1
S
.
B
I
R
C
H
S
T
.
,
S
A
N
T
A
A
N
A
,
C
A
9
0
7
2
7
-
SF
R
15
1
3
S
.
B
I
R
C
H
S
T
.
,
S
A
N
T
A
A
N
A
,
C
A
9
0
7
2
7
-
AD
U
“Structural Calculations”
1ST SUBMITTAL – 11/24
2ND SUBMITTAL- 03/25
GARAGE CONVERSION
FOR: SILVIA TORRES
Project Site: 1511 S BIRCH ST.
SANTA ANA, CA 92707
CALCULATIONS BY: K. CHAVEZ
CHECKED BY: FRANCISCO GARCIA, P.E - - - TEL. (323) 717-1303
600 W. MAIN ST. SUITE 200. ALHAMBRA CA, 91801
1/26
03/28/2025
TABLE OF CONTENTS
1) LOADING CONDITIONS ..................................................................... 3
2) ROOF, CEILING FRAMING LOADING ............................................. 4
3) ROOF, CEILING FRAMING RESULTS ............................................. 6
4) SEISMIC DESIGN AND DISTRIBUTION PER [ASCE7-16] ............. 8
5) WIND DESIGN PER [ASCE7-16] ......................................................... 13
6) LATERAL ANALYSIS .......................................................................... 14
7) WOOD COLUMN DESIGN .................................................................. 21
8) LEDGER CHECK ................................................................................... 25
9) DETERMINATION OF CONCRETE PADS ........................................ 26
2/26
03/28/2025
PROJECT SITE: 1511 S BIRCH ST. SANTA ANA, CA 92707
DESIGN CRITERIA
CODE: CALIFORNIA BUILDING CODE-2022 EDITION
MATERIALS:
• TIMBER - DOUGLAS FIR LARCH
RAFTERS & JOIST - #2 GRADE
BEAMS, HEADERS, & POSTS - #1 GRADE UNLESS OTHERWISE NOTED (U.N.O.)
PLYWOOD - PS 1-95, PER APA STANDARD, PI. 32/16
• CONCRETE – F’c=2500 PSI @ 28 DAYS
• REINFORCING STEEL - ASTM A-615
#4 AND SMALLER, GRADE 40
#5 AND LARGER, GRADE 60
• SOIL PRESSURE - 1,500 PSF PER [TABLE 1806.2]
• LOADS -
(EXTERIOR WALL) PSF
FRAMING (2X4 @16") 1.9
PLYWOOD SHEATHING 1.5
STUCCO 8.0
INSULATION - R-13 1.5
1/2" GYP. BOARD 2.5
MISCELLANEOUS 0.6
TOTAL D.L. = 16 PSF
(INTERIOR WALL) PSF
FRAMING (2X4 @16") 1.9
INSULATION - R-13 1.5
1/2" GYP. BOARD 2.5
MISCELLANEOUS 2.1
TOTAL D.L. = 8 PSF
WALL LOAD AVERAGE = (16+8)/2 = 12PSF
(ROOF) PSF
ROOFING MATERIAL 6.0
PLYWOOD SHEATHING 1.5
FRAMING 1.8
MISCELLANEOUS 1.2
TOTAL D.L. = 10.5 PSF
L.L. = 20 PSF
(ROOF) -VAULTED- PSF
ROOFING MATERIAL 6.0
PLYWOOD SHEATHING 1.5
FRAMING 2.4
INSULATION- R-30 2.1
1/2" GYP. BOARD 2.5
MISCELLANEOUS 1.5
TOTAL D.L. = 16 PSF
L.L. = 20 PSF
(CEILING) PSF
INSULATION - R-30 2.1
1/2" GYP. BOARD 2.5
FRAMING 1.9
MISCELLANEOUS 1.0
TOTAL D.L. = 7.5 PSF
L.L. = 10 PSF
3/26
pg.6
pg.6
4/26
pg.7
pg.7
5/26
Multiple Simple Beam
ALONSO H. CORONELLic. # : KW-06005817
FJ Engineering
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.5.17
File: BIRCH_ENERCALC.ec6
Project Title:BIRCHEngineer:K. CHAVEZProject ID:
Printed: 18 NOV 2024, 9:53AM
Project Descr:
Description :
BEAM Size :2x10, Sawn, Fully BracedUsing Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Beam Design :
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
Douglas Fir-Larch No.2900.0900.0 1,350.0625.0 1,600.0580.0180.0575.0 31.210Eminbend - xx ksi
Wood Species :Wood Grade :Fb - Tension psipsi Fv psiFb - Compr Ft psiFc - Prll psipsiFc - Perp Ebend- xx ksi Density pcf
RR-1
Applied Loads
Unif Load: D = 0.0160, Lr = 0.020 k/ft, Trib= 1.333 ft
.Design Summary
Max fb/Fb Ratio =0.766 : 1
Max Reactions (k)HEWSLrL
+D+Lr+HLoad Comb :
Span # 1
Left Support
D
in
9.000 inft
42.96 psi
Fb : Allowable :1,423.13 psi
Right Support
Fv : Allowable :Span # 1
Load Comb :+D+Lr+H225.00 psi
fb : Actual :
Max fv/FvRatio =0.191 : 1 0.000 ft
1,090.30 psi at
atfv : Actual :
Ratio 9999 Ratio 9999
Max DeflectionsTransient Downward 0.400 in
Transient Upward 0.000 in
Total Downward 0.720 in
Total Upward 0.000 in
0.19 0.240.19 0.24 Ratio 540 300Ratio
LC: Lr Only LC: +D+Lr+H
LC:LC:
BEAM Size :2x6, Sawn, Braced @ Mid SpanUsing Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Beam Design :
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
Douglas Fir-Larch No.2900.0900.0 1,350.0625.0 1,600.0580.0180.0575.0 31.210Eminbend - xx ksi
Wood Species :Wood Grade :Fb - Tension psipsi Fv psiFb - Compr Ft psiFc - Prll psipsiFc - Perp Ebend- xx ksi Density pcf
RR-2
Applied Loads
Unif Load: D = 0.01050, Lr = 0.020 k/ft, Trib= 1.333 ft
.Design Summary
Max fb/Fb Ratio =0.810 : 1
Max Reactions (k)HEWSLrL
+D+Lr+HLoad Comb :
Span # 1
Left Support
D
in
6.125 inft
41.96 psi
Fb : Allowable :1,494.18 psi
Right Support
Fv : Allowable :Span # 1
Load Comb :+D+Lr+H225.00 psi
fb : Actual :
Max fv/FvRatio =0.186 : 1 0.000 ft
1,210.12 psi at
atfv : Actual :
Ratio 9999 Ratio 9999
Max DeflectionsTransient Downward 0.408 in
Transient Upward 0.000 in
Total Downward 0.622 in
Total Upward 0.000 in
0.09 0.160.09 0.16 Ratio 360 236Ratio
LC: Lr Only LC: +D+Lr+H
LC:LC:
6/26
Multiple Simple Beam
ALONSO H. CORONELLic. # : KW-06005817
FJ Engineering
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.5.17
File: BIRCH_ENERCALC.ec6
Project Title:BIRCHEngineer:K. CHAVEZProject ID:
Printed: 18 NOV 2024, 9:53AM
Project Descr:
BEAM Size :4x10, Sawn, Fully UnbracedUsing Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Beam Design :
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
Douglas Fir-Larch No.11,000.01,000.0 1,500.0625.0 1,700.0620.0180.0675.0 31.210Eminbend - xx ksi
Wood Species :Wood Grade :Fb - Tension psipsi Fv psiFb - Compr Ft psiFc - Prll psipsiFc - Perp Ebend- xx ksi Density pcf
BM-1
Applied Loads
Beam self weight calculated and added to loads
Unif Load: D = 0.06450, Lr = 0.1225 k/ft, Trib= 1.0 ft
.Design Summary
Max fb/Fb Ratio =0.793 : 1
Max Reactions (k)HEWSLrL
+D+Lr+HLoad Comb :
Span # 1
Left Support
D
in
7.000 inft
56.21 psi
Fb : Allowable :1,440.92 psi
Right Support
Fv : Allowable :Span # 1
Load Comb :+D+Lr+H225.00 psi
fb : Actual :
Max fv/FvRatio =0.250 : 1 13.253 ft
1,142.84 psi at
atfv : Actual :
Ratio 9999 Ratio 9999
Max DeflectionsTransient Downward 0.271 in
Transient Upward 0.000 in
Total Downward 0.430 in
Total Upward 0.000 in
0.50 0.860.50 0.86 Ratio 619 391Ratio
LC: Lr Only LC: +D+Lr+H
LC:LC:
BEAM Size :2x8, Sawn, Braced @ 1/3 PointsUsing Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending
Wood Beam Design :
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
Douglas Fir-Larch No.2900.0900.0 1,350.0625.0 1,600.0580.0180.0575.0 31.210Eminbend - xx ksi
Wood Species :Wood Grade :Fb - Tension psipsi Fv psiFb - Compr Ft psiFc - Prll psipsiFc - Perp Ebend- xx ksi Density pcf
CJ-1
Applied Loads
Unif Load: D = 0.00750, L = 0.010 k/ft, Trib= 1.0 ft
Point: D = 0.06560, Lr = 0.1250 k @ 5.0 ft
Point: D = 0.06560, Lr = 0.1250 k @ 12.50 ft
.Design Summary
Max fb/Fb Ratio =0.975 : 1
Max Reactions (k)HEWSLrL
+D+0.750Lr+0.750L+HLoad Comb :
Span # 1
Left Support
D
in
8.750 inft
38.88 psi
Fb : Allowable :1,283.61 psi
Right Support
Fv : Allowable :Span # 1
Load Comb :+D+0.750Lr+0.750L+H225.00 psi
fb : Actual :
Max fv/FvRatio =0.173 : 1 0.000 ft
1,251.97 psi at
atfv : Actual :
Ratio 9999 Ratio 9999
Max DeflectionsTransient Downward 0.486 in
Transient Upward 0.000 in
Total Downward 1.037 in
Total Upward 0.000 in
0.13 0.09 0.130.13 0.09 0.13 Ratio 432 202Ratio
LC: Lr Only LC: +D+0.750Lr+0.750L+H
LC:LC:
7/26
!
"#
!$%$$&'()*+&,-&./,.0/.-1023454-6&07.,(,89:-7;/<(,89:=>>?43@@452-A$$4?B45@3$$C.,:DEFGGFGEGHDDIJJIHKLMC:N(</1;9:O:P:):/*:C;*8Q:/, LRSTUDVO(NW1.,:<;)X YY&(,:1Z.NN [U[\DD!H!J]^X_:`.Z8: C:N*)(_,(;/D!GaK MRSb
!\ E!G
]D E!HKc MRSb
!\ D!E
]MD!KHG U
MD UDD!H!a U
[D!EGa d
E!G
L[D UDD!H!a d
D!E
L^X_:`.Z8: C:N*)(_,(;/[R UDD!H!a
efD!G E!G
f
UDD!H!a D!E
gL E!KHH MRS"
fgL D!G gLgLM E!VKJ
"
hi a iU
bh D!GaK g "U
!\E!G
] j D!JaJ f
Uk
\Gl e#
KEe ] [D!Kaa f
!\E!G
]Dbh E!HKc g "U
!\D!E
]D j E!HcV f
Uk
\Gl e#
KEe ] !D[ E!V f
!\D!E
]gL
E!VK f
!\g"
L ]
8/26
II
r =Wo =
9/26
r
10/26
II
r =Wo =
11/26
r
12/26
WIND DESIGN Based on ASCE 7-16 [Ch. 28]
WIND DESIGN
[28.5] Method 2: Enclosed Simple Diaphragm Low-Rise Buildings
DESIGN CRITERIA:
RISK CATEGORY =II
WIND SPEED, V = 110 MPH
EXPOSURE = B
ROOF SLOPE =4/12
θ=18.43
ROOF HEIGHT, h =12.0 FT (max)
NET PRESSURE:
p s =λ K zt p S30 (EQ. 28.5-1)
θ
h ZONE A
(WALL)
ZONE B
(ROOF)
END ZONE
D
p s =λ K zt p S30 (EQ. 28.5-1)
λ = 1.00 ADJUSTMENT FACTOR [FIG. 28.5-1]
K zt =1.0 TOPOGRAPHIC FACTOR
(p S30 )A=25.82 PSF - ZONE A, WALL END ZONE [FIG. 28.5-1] ~ WORST CASE ~
(p S30 )D=-4.1 PSF - ZONE D, ROOF END ZONE [FIG. 28.5-1]
(p S )A=1.00 1.0 25.82 25.82 PSF
(p S )D=1.00 1.0 -4.12 -4.12 PSF
THEREFORE:
(p S )A=25.82 15.49 PSF {PER 28.5.4} Zone A
(p S )D=-4.12 -2.47 PSF {PER 28.5.4} Zone D
(ASD LOAD COMBINATION FACTOR FOR WIND)
< 16 PSF MIN.
< 8 PSF MIN.
0.6 *( ) =
( ) ( )( PSF) =
0.6 *( ) =
( ) ( )( PSF) =
13/26
WIND ZONES BIRCH 1511 PROJECT
LATERAL DESIGN
PsA 16psf:=Zone A
PsD 8psf:=Zone D
________________________________________________________________________________________
SEISMIC @ ROOF LEVEL ON LINE ( E )
Vroof 4.93 psf=
VS Vroof 20 ft18.5 ft
2
:=VS 912 lb=- - CONTROLS - -
WIND
Tributary Width
Between Supports Zone A (wall) Zone D (roof)
PsA 16 psf=Hw 8 ft=PsD 8 psf=Hr 4 ft=W 18.5ft 0ft+:=
VW PsA
Hw
2
PsD Hr( )+
W
2
:=VW 888 lb=
SHEARWALL DESIGN
Lw 4ft 0ft+:=Lw 4 ft=
VS 912 lb= Seismic controls
υs
VS
Lw
:=υs 228.01 lb
ft=< 320 lb/ft USE S.W. = 2
OVERTURNING Lmin 4ft:=H 8ft:=SDS 1.028=
OTM υs( )Lmin( )H( ):=OTM 7296.4 lb ft=
Wall
RM 12psf H( )
Lmin( )2
2:=RM 768 lb ft=
USE SIMPSON "HDU2"
HOLDOWNT
OTM 0.9 0.2SDS-()RM-
Lmin
:=T 1690.78 lb=
ANCHOR BOLTS :> USE 5/8" f X L= 12" @ 32" O.C.
________________________________________________________________________________________
14/26
SEISMIC @ ROOF LEVEL ON LINE ( D )
Vroof 4.93 psf=
VS Vroof 18.5 ft13.5 ft
2
:=VS 615.6 lb=
WIND
Tributary Width
Between Supports Zone A (wall) Zone D (roof)
PsA 16 psf=Hw 8 ft=PsD 8 psf=Hr 4 ft=W 13.5ft 0ft+:=
VW PsA
Hw
2
PsD Hr( )+
W
2
:=VW 648 lb=- - CONTROLS - -
SHEARWALL DESIGN Lw 4ft 0ft+:=Lw 4 ft=
VW 648 lb= Wind controls
υs
VW
Lw
:=υs 162 lb
ft=< 210 lb/ft USE S.W. = 1
OVERTURNING Lmin 4ft:=H 8ft:=SDS 1.028=
OTM υs( )Lmin( )H( ):=OTM 5184 lb ft=
Wall
RM 12psf H( )
Lmin( )2
2:=RM 768 lb ft=
USE SIMPSON "HDU2"
HOLDOWNT
OTM 0.9 0.2SDS-()RM-
Lmin
:=T 1162.68 lb=
ANCHOR BOLTS :> USE 5/8" f X L= 12" @ 48" O.C.
________________________________________________________________________________________
15/26
SEISMIC @ ROOF LEVEL ON LINE ( B )
Vroof 4.93 psf=
VS Vroof 18.5 ft13.5 ft
2
:=VS 615.6 lb=
WIND
Tributary Width
Between Supports Zone A (wall) Zone D (roof)
PsA 16 psf=Hw 8 ft=PsD 8 psf=Hr 4 ft=W 13.5ft 0ft+:=
VW PsA
Hw
2
PsD Hr( )+
W
2
:=VW 648 lb=- - CONTROLS - -
SHEARWALL DESIGN Lw 4ft 0ft+:=Lw 4 ft=
VW 648 lb= Wind controls
υs
VW
Lw
:=υs 162 lb
ft=< 210 lb/ft USE S.W. = 1
OVERTURNING Lmin 4ft:=H 8ft:=SDS 1.028=
OTM υs( )Lmin( )H( ):=OTM 5184 lb ft=
Wall
RM 12psf H( )
Lmin( )2
2:=RM 768 lb ft=
USE SIMPSON "HDU2"
HOLDOWNT
OTM 0.9 0.2SDS-()RM-
Lmin
:=T 1162.68 lb=
ANCHOR BOLTS :> USE 5/8" f X L= 12" @ 48" O.C.
________________________________________________________________________________________
16/26
SEISMIC @ ROOF LEVEL ON LINE ( A )
Vroof 4.93 psf=
VS Vroof 20 ft18.5 ft
2
:=VS 912 lb=- - CONTROLS - -
WIND
Tributary Width
Between Supports Zone A (wall) Zone D (roof)
PsA 16 psf=Hw 8 ft=PsD 8 psf=Hr 4 ft=W 18.5ft 0ft+:=
VW PsA
Hw
2
PsD Hr( )+
W
2
:=VW 888 lb=
SHEARWALL DESIGN Lw 4ft 0ft+:=Lw 4 ft=
VS 912 lb= Seismic Controls
υs
VS
Lw
:=υs 228.01 lb
ft=< 320 lb/ft USE S.W. = 2
OVERTURNING Lmin 4ft:=H 8ft:=SDS 1.028=
OTM υs( )Lmin( )H( ):=OTM 7296.4 lb ft=
Wall
RM 12psf H( )
Lmin( )2
2:=RM 768 lb ft=
USE SIMPSON "HDU2"
HOLDOWNT
OTM 0.9 0.2SDS-()RM-
Lmin
:=T 1690.78 lb=
ANCHOR BOLTS :> USE 5/8" f X L= 12" @ 32" O.C.
________________________________________________________________________________________
17/26
SEISMIC @ ROOF LEVEL ON LINE ( 6 )
Vroof 4.93 psf=
VS Vroof 13.5 ft18.5 ft
2
:=VS 615.6 lb=
WIND
Tributary Width
Between Supports Zone A (wall) Zone D (roof)
PsA 16 psf=Hw 8 ft=PsD 8 psf=Hr 4 ft=W 18.5ft 0ft+:=
VW PsA
Hw
2
PsD Hr( )+
W
2
:=VW 888 lb=- - CONTROLS - -
SHEARWALL DESIGN Lw 4ft 0ft+:=Lw 4 ft=
VW 888 lb= Wind Controls
υs
VW
Lw
:=υs 222 lb
ft=< 320 lb/ft USE S.W. = 2
OVERTURNING Lmin 4ft:=H 8ft:=SDS 1.028=
OTM υs( )Lmin( )H( ):=OTM 7104 lb ft=
Wall
RM 12psf H( )
Lmin( )2
2:=RM 768 lb ft=
USE SIMPSON "HDU2"
HOLDOWNT
OTM 0.9 0.2SDS-()RM-
Lmin
:=T 1642.68 lb=
ANCHOR BOLTS :> USE 5/8" f X L= 12" @ 32" O.C.
________________________________________________________________________________________
18/26
SEISMIC @ ROOF LEVEL ON LINE ( 5 )
Vroof 4.93 psf=
VS Vroof 13.5 ft18.5 ft
2
18.5 ft20 ft
2
+
:=VS 1527.7 lb=
WIND
Tributary Width
Between Supports Zone A (wall) Zone D (roof)
PsA 16 psf=Hw 8 ft=PsD 8 psf=Hr 4 ft=W 18.5ft 20ft+:=
VW PsA
Hw
2
PsD Hr( )+
W
2
:=VW 1848 lb=- - CONTROLS - -
SHEARWALL DESIGN Lw 8ft 0ft+:=Lw 8 ft=
VW 1848 lb= Wind Controls
υs
VW
Lw
:=υs 231 lb
ft=< 320 lb/ft USE S.W. = 2
OVERTURNING Lmin 8ft:=H 8ft:=SDS 1.028=
OTM υs( )Lmin( )H( ):=OTM lb ft=
Wall
RM 12psf H( )
Lmin( )2
2:=RM 3072 lb ft=
USE SIMPSON "HDU2"
HOLDOWNT
OTM 0.9 0.2SDS-()RM-
Lmin
:=T 1581.35 lb=
ANCHOR BOLTS :> USE 5/8" f X L= 12" @ 32" O.C.
________________________________________________________________________________________
19/26
SEISMIC @ ROOF LEVEL ON LINE ( 2 )
Vroof 4.93 psf=
VS Vroof 18.5 ft20 ft
2
:=VS 912 lb=
WIND
Tributary Width
Between Supports Zone A (wall) Zone D (roof)
PsA psf=Hw 8 ft=PsD 8 psf=Hr 4 ft=W 20ft 0ft+:=
VW PsA
Hw
2
PsD Hr( )+
W
2
:=VW 960 lb=- - CONTROLS - -
SHEARWALL DESIGN Lw 4ft 0ft+:=Lw 4 ft=
VW 960 lb= Wind Controls
υs
VW
Lw
:=υs 240 lb
ft=< 320 lb/ft USE S.W. = 2
OVERTURNING Lmin 4ft:=H 8ft:=SDS 1.028=
OTM υs( )Lmin( )H( ):=OTM 7680 lb ft=
Wall
RM 12psf H( )
Lmin( )2
2:=RM 768 lb ft=
USE SIMPSON "HDU2"
HOLDOWNT
OTM 0.9 0.2SDS-()RM-
Lmin
:=T 1786.68 lb=
ANCHOR BOLTS :> USE 5/8" f X L= 12" @ 32" O.C.
________________________________________________________________________________________
20/26
pg.22-24
21/26
Wood Column
ALONSO H. CORONELLic. # : KW-06005817
DESCRIPTION:WOOD COLUMN DESIGN
FJ Engineering
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.5.17
File: BIRCH_ENERCALC.ec6
Project Title:BIRCHEngineer:K. CHAVEZProject ID:
Printed: 18 NOV 2024, 9:56AM
Project Descr:
.Code References
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combinations Used : ASCE 7-16
General Information
Wood Section Name 4x6Analysis Method :
8Overall Column Height ft
Load Resistance Factor Design
( Used for non-slender calculations )Allow Stress Modification Factors
End Fixities Top & Bottom Pinned
Wood Species Douglas Fir-Larch
Wood Grade No.1
Fb +1,350.0
1,350.0 psi
925.0
625.0
170.0
675.0
31.210
psi Fv psi
Fb -Ft psi
Fc - Prll psi
psi
Density pcf
Fc - Perp
E : Modulus of Elasticity . . .
1,600.0
580.0
1,600.0
580.0
Cfu : Flat Use Factor 1.0
Cf or Cv for Tension 1.30
Use Cr : Repetitive ?
Kf : Built-up columns 1.0 NDS 15.3.2
Exact Width 3.50 in
Exact Depth 5.50 in
Area 19.250 in^2
Ix 48.526 in^4
Iy 19.651 in^4
Wood Grading/Manuf.Graded Lumber
Wood Member Type Sawn
Ct : Temperature Factor 1.0
Cf or Cv for Compression 1.10
1,600.0
Axial
Cm : Wet Use Factor 1.0
Cf or Cv for Bending 1.30
x-x Bending y-y Bending
ksi NoMinimum
Basic
Y-Y (depth) axis :
X-X (width) axis :
Unbraced Length for buckling ABOUT X-X Axis = 8 ft, K = 1.0
Unbraced Length for buckling ABOUT Y-Y Axis = 8 ft, K = 1.0
Brace condition for deflection (buckling) along columns :
.Service loads entered. Load Factors will be applied for calculations.Applied Loads
Column self weight included : 33.377 lbs * Dead Load Factor
AXIAL LOADS . . .
Axial Load at 8.0 ft, D = 0.50, L = 0.860 k
BENDING LOADS . . .
Moment acting about X-X axis at 7.0 ft, E = 2.807 k-ft
.DESIGN SUMMARY
PASS
PASS
Max. Axial+Bending Stress Ratio =0.7066
Location of max.above base 6.980 ft
Applied Axial 1.610 k
Applied Mx 3.674 k-ft
Load Combination +1.406D+L+1.50E
Load Combination +0.6944D-1.50E
Bending & Shear Check Results
Maximum Shear Stress Ratio =
Applied Design Shear 41.011 psi
367.20Allowable Shear psi
0.07446 : 1 Bending Compression Tension
LRFD - Format Conversion factor 2.541 2.400 2.700
LRFD - Resistance factor 0.850 0.900 0.800Location of max.above base 0.0 ft
: 1
At maximum location values are . . .
Applied My 0.0 k-ft
Maximum SERVICE Lateral Load Reactions . .
Top along Y-Y 0.3509 k Bottom along Y-Y 0.3509 k
Top along X-X 0.0 k Bottom along X-X 0.0 kGoverning NDS Forumla111Comp + Mxx, NDS Eq. 3.9-3
Maximum SERVICE Load Lateral Deflections . . .
Along Y-Y 0.2408 in at 4.510 ft above base
for load combination :E Only
Along X-X 0.0 in at 0.0 ft above base
Fc : Allowable 845.01 psi
Other Factors used to calculate allowable stresses . . .
for load combination :n/a
.
Maximum Axial + Bending Stress Ratios Maximum Shear RatiosCLambdaLoad Combination Stress Ratio Location Stress Ratio Status LocationPStatus
Load Combination Results
+1.40D 0.600 PASS PASS0.0 0.0 0.0 ft0.570 ft0.05162
+1.20D+1.60L 0.800 PASS PASS0.0 0.0 0.0 ft0.462 ft0.1291
+1.20D+L 0.800 PASS PASS0.0 0.0 0.0 ft0.462 ft0.09603
+1.20D 0.800 PASS PASS0.0 0.0 0.0 ft0.462 ft0.04097
+0.90D 1.000 PASS PASS0.0 0.0 0.0 ft0.384 ft0.02951
+1.406D+L+1.50E 1.000 PASS PASS6.980 0.07446 0.0 ft0.384 ft0.7066
+1.406D+L-1.50E 1.000 PASS PASS6.980 0.07446 0.0 ft0.384 ft0.7066
+0.6944D+1.50E 1.000 PASS PASS6.980 0.07446 0.0 ft0.384 ft0.6781
+0.6944D-1.50E 1.000 PASS PASS6.980 0.07446 0.0 ft0.384 ft0.6781
.
22/26
Wood Column
ALONSO H. CORONELLic. # : KW-06005817
DESCRIPTION:WOOD COLUMN DESIGN
FJ Engineering
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.5.17
File: BIRCH_ENERCALC.ec6
Project Title:BIRCHEngineer:K. CHAVEZProject ID:
Printed: 18 NOV 2024, 9:56AM
Project Descr:
k k-ft
Note: Only non-zero reactions are listed.
Load Combination
X-X Axis Reaction Y-Y Axis Reaction Axial Reaction
@ Base @ Top @ Base@ Base @ Top
Maximum Reactions
@ Base @ Base@ Top @ Top
My - End Moments Mx - End Moments
D Only 0.533
+D+L 1.393
+D+0.750L 1.178
+0.60D 0.320
+D+0.70E -0.246 0.5330.246
+D-0.70E 0.246 0.533-0.246
+D+0.750L+0.5250E -0.184 1.1780.184
+D+0.750L-0.5250E 0.184 1.178-0.184
+0.60D+0.70E -0.246 0.3200.246
+0.60D-0.70E 0.246 0.320-0.246
L Only 0.860
E Only -0.3510.351
E Only * -1.0 0.351-0.351
.Maximum Deflections for Load Combinations
Max. X-X Deflection Max. Y-Y Deflection DistanceLoad Combination Distance
D Only 0.0000 0.0000 0.000 ftftinin0.000
+D+L 0.0000 0.0000 0.000 ftftinin0.000
+D+0.750L 0.0000 0.0000 0.000 ftftinin0.000
+0.60D 0.0000 0.0000 0.000 ftftinin0.000
+D+0.70E 0.0000 0.1686 4.510 ftftinin0.000
+D-0.70E 0.0000 -0.1686 4.510 ftftinin0.000
+D+0.750L+0.5250E 0.0000 0.1264 4.510 ftftinin0.000
+D+0.750L-0.5250E 0.0000 -0.1264 4.510 ftftinin0.000
+0.60D+0.70E 0.0000 0.1686 4.510 ftftinin0.000
+0.60D-0.70E 0.0000 -0.1686 4.510 ftftinin0.000
L Only 0.0000 0.0000 0.000 ftftinin0.000
E Only 0.0000 0.2408 4.510 ftftinin0.000
E Only * -1.0 0.0000 -0.2408 4.510 ftftinin0.000
.
23/26
Wood Column
ALONSO H. CORONELLic. # : KW-06005817
DESCRIPTION:WOOD COLUMN DESIGN
FJ Engineering
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.5.17
File: BIRCH_ENERCALC.ec6
Project Title:BIRCHEngineer:K. CHAVEZProject ID:
Printed: 18 NOV 2024, 9:56AM
Project Descr:
Sketches
24/26
25/26
DE
T
E
R
M
I
N
A
T
I
O
N
O
F
C
O
N
C
R
E
T
E
P
A
D
S
PR
O
J
E
C
T
#
B
I
R
C
H
SO
I
L
B
E
A
R
I
N
G
CO
N
C
.
W
T
H
(P
S
F
)
(L
B
/
F
T
3)
(F
T
)
15
0
0
15
0
1
.
5
AC
T
U
A
L
D
I
M
.
U
S
E
D
D
I
M
.
BE
A
M
#
DE
A
D
L
I
V
E
S
E
I
S
M
I
C
T
O
T
A
L
C
O
N
C
R
E
T
E
P
A
D
C
O
N
C
R
E
T
E
P
A
D
(
L
)
R
E
A
C
T
I
O
N
(
B
M
-
3
)
50
0
l
b
8
6
0
l
b
13
6
0
l
b
1.
0
3
f
t
1.
5
S
Q
f
t
→
TH
E
R
E
F
O
R
E
U
S
E
(
3
)
#
4
R
E
B
A
R
E
A
C
H
W
A
Y
TO
T
A
L
R
E
A
C
T
I
O
N
w
P
v
s
o
i
l
Co
n
c
wt
h
26/26
%8,/',1*(1(5*<$1$/<6,65(3257
352-(&7
1513 S. BIRCH STREET
SANTA ANA, CA 90727
3URMHFW'HVLJQHU
LUIS N. OROZCO
562.661.9281
5HSRUW3UHSDUHGE\
LRG ENERGY DESIGN
P.O. BOX 470011
LOS ANGELES, CA 90047
(323)955-9827
-RE1XPEHU
244371
'DWH
11/11/2024
7$%/(2)&217(176
&RYHU3DJH
7DEOHRI&RQWHQWV
)RUP&)535)(&HUWLILFDWHRI&RPSOLDQFH
)RUP0)50DQGDWRU\0HDVXUHV6XPPDU\
3
14
!"#$%& '$((')*+%,-.($ #,- /0/123145467758'49:96;75:955<
=>? /0/12@1A12'#'B(46%,CDB#)-%( 2A01/ !"#$%& '$((')*+E))F!GHIJ44
$KLHMNGONHPQ-RSIKG9 $KLHMNGONHPQ*ONKT'HSK9 &($ DGPUHJKG9%)"RHVJHQL(QKGLW(XXHYHKQYW NOQJOGJM74544$KMHJKQNHOV%PSZVHOQYK $KZPGN.KGMHPQ94544!5!555 Y[KSO.KGMHPQ9GKU45445;5$KZPGN\KQKGONKJ94546775859]95
^
!"#$%& '$((')*+%,-.($ #,-021/'#'B(46%,CDB#)-%(
12 !"#$%& '$(('