HomeMy WebLinkAbout2219 N Spurgeon St - Plan (2)PAGE REV: G 5/28/2025 GILBERT VAN DER MARLIERE 2219 N SPURGEON ST, SANTA ANA, CA, 92706 PROJECT NUMBER: 109R-219VAND SHEET DESIGNER: CODY ZEMKE CUSTOMER RESIDENCE: TEL. (714) 381-7691 APN: 003-120-24 (415) 580-6920 ex3 Template_version_v5_2024.07.26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 COVER SHEET SCOPE OF WORK GENERAL NOTES PV-1.0 VICINITY MAP #SSTAMPCS #ESTAMPCS ABBREVIATIONS A AMPERE AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT (E)EXISTING ESS ENERGY STORAGE SYSTEM MSP MAIN SERVICE PANEL (N)NEW PRE-FAB PRE-FABRICATED PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS V VOLTS W WATTS SHEET INDEX • EXISTING SOLAR SYSTEM INSTALLED. • ALL WORK SHALL COMPLY WITH 2022 CRC/CBC/CEBC, MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2022 CEC. • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(D). • 12.5 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (A)(1) & 690.8 (B)]. • ENERGY STORAGE SYSTEM CONFORMS TO AND IS LISTED UNDER UL 9540. • ENERGY STORAGE SYSTEM LIVE PARTS ARE NOT ACCESSIBLE DURING ROUTINE MAINTENANCE. SYSTEM VOLTAGE IN ACCORDANCE WITH CEC 706.20 AND EXCEPTION 1 CEC 706.20 (B). • ADDITIONAL DISCONNECTING MEANS SHALL BE INSTALLED WHERE THE CIRCUITS FROM THESE TERMINALS PASS THROUGH A WALL OR PARTITION PER 706.15(D). • LISTED, COMBINATION TYPE AFCI SHALL BE INSTALLED WHERE BACKED UP CIRCUIT WIRING IS EXTENDED MORE THAN 6FT AND DOES NOT INCLUDE ANY ADDITIONAL OUTLETS OR DEVICES PER CEC 210.12(D). • ALL PASS-THROUGH CONDUCTORS MUST COMPLY WITH CEC 312.8 • THE CAPACITY OF THE STANDALONE SYSTEM SUPPLY SHALL BE EQUAL TO OR GREATER THAN THE LOAD POSED BY THE SINGLE LARGEST UTILIZATION EQUIPMENT CONNECTED TO THE SYSTEM PER CEC ARTICLE 710.15(A) PAGE #DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-2.1 ESS ELEVATION VIEW PV-2.2 GARAGE FLOOR PLAN PV-4.0 ELECTRICAL PV-4.1 ELECTRICAL CALCS PV-4.2 BACKUP LOAD CALCS PV-4.3 PANEL SCHEDULE PV-5.0 SIGNAGE (1) RESIDIO HEAT SENSOR • BACKUP GATEWAY: (1) 200A TESLA POWERWALL CONTROL PANEL • POWER CONTROLLED SYSTEM (PCS) ENABLED EQUIPMENT INSTALLED, SEE PV-4.0 FOR INTERCONNECTION DETAILS • ENERGY STORAGE SYSTEM: (3) TESLA: POWERWALL 3 1707000-XX-Y 13.5KWH, 5KW INVERTER OUTPUT , LITHIUM-ION BATTERY (WEIGHT; 287LB EACH ) G Revision to 20184381 (issued on 1/24/25) Rev 1 #20185838 APPROVALS:ELECT - M. Smith PAGE REV: G 5/28/2025 GILBERT VAN DER MARLIERE 2219 N SPURGEON ST, SANTA ANA, CA, 92706 PROJECT NUMBER: 109R-219VAND SHEET DESIGNER: CODY ZEMKE CUSTOMER RESIDENCE: TEL. (714) 381-7691 APN: 003-120-24 (415) 580-6920 ex3 Template_version_v5_2024.07.26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 ESS ELEVATION VIEW PV-2.1 #SSTAMPSP #ESTAMPSP SITE PLAN - SCALE = NTS INTERIOR EAST WALL - GARAGE G 3' MIN 3' MIN ACD RESIDIO HEAT SENSOR ESS INTERIOR INSTALLATION WILL COMPLY WITH SMOKE AND HEAT MONITORING REQUIREMENTS FOR 2022 CFC 1207.11.6 ESS INTERIOR INSTALLATION LOCATION WILL COMPLY WITH IMPACT PROTECTION REQUIREMENTS FOR 2022 CFC 1207.11.7.3 ACD ACD POWREWALL 3 POWERWALL 3 POWERWALL 3 ESS ELEVATION VIEW PAGE REV: G 5/28/2025 GILBERT VAN DER MARLIERE 2219 N SPURGEON ST, SANTA ANA, CA, 92706 PROJECT NUMBER: 109R-219VAND SHEET DESIGNER: CODY ZEMKE CUSTOMER RESIDENCE: TEL. (714) 381-7691 APN: 003-120-24 (415) 580-6920 ex3 Template_version_v5_2024.07.26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 GARAGE FLOOR PLAN PV-2.2 #SSTAMPSP #ESTAMPSP SITE PLAN - SCALE = NTS AC AC AC GARAGE FLOOR PLANINTERIOR DOOR RESIDIO HEAT SENSOR G 9" NOTE: GARAGE WALL BATTERY MOUNTED ON IS NOT SEPARATING THE GARAGE FROM HABITABLE SPACE NOTE: ESS DOES NOT EMIT FLAMMABLE GASSES AND THEREFORE DOES NOT REQUIRE ADDITIONAL VENTILATION NOTE: GARAGE WALL BATTERY MOUNTED ON IS SEPERATING THE GARAGE FROM EXTERIOR SPACE NOTE: ESS INTERIOR INSTALLABLE SHALL COMPLY WITH SMOKE AND HEAT MONITORING REQUIREMENTS FOR 2022 CFC 1207.11.6 NOTE: ESS INTERIOR INSTALLABLE SHALL COMPLY WITH IMPACT PROTECTION REQUIREMENTS FOR 2022 CFC 1207.11.7.3 20' 20' 9" PAGE REV: G 5/28/2025 GILBERT VAN DER MARLIERE 2219 N SPURGEON ST, SANTA ANA, CA, 92706 PROJECT NUMBER: 109R-219VAND SHEET DESIGNER: CODY ZEMKE CUSTOMER RESIDENCE: TEL. (714) 381-7691 APN: 003-120-24 (415) 580-6920 ex3 Template_version_v5_2024.07.26 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 2 (N) 225A BACKUP LOAD PANEL(E) BACKUP LOADS (N) 100A MAIN BREAKER M CTRL(N) 200A BACKUP GATEWAY 1 2 FACILITY GROUND RELOCATED (E) FACILITY LOADS EXISTING 200A MAIN PANEL M METER #: SCE 120/240 VAC SINGLE PHASE SERVICEUTILITY GRID (N) 100A GATEWAY FEEDER BREAKER AT OPPOSITE END OF BUSBAR (N) SITE CURRENT TRANSFORMERSNEURIO METER EXISTING 200A MAIN BREAKER (END FED) + - (N) IMO PE69-3020, DISCONNECT SWITCH, 3P, 16A RSD + - TESLA: POWERWALL 3 1707000-XX-Y POWER CONTROL SYSTEM RSD ENERGY STORAGE SYSTEM TESLA: POWERWALL 3 1707000-XX-Y ENERGY STORAGE SYSTEM POWER CONTROL SYSTEM 1 + - POWER CONTROL SYSTEM RSD ENERGY STORAGE SYSTEM (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A,2P 120/240VAC (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A,2P 120/240VAC (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A,2P 120/240VAC 1 111 1 TESLA: POWERWALL 3 1707000-XX-Y 200A GATEWAY INTERNAL PANELBOARD 1 (1) SOLAR PV CURRENT TRANSFORMER (E) 35A PV BREAKER AT OPPOSITE END OF BUSBAR E JUNCTION BOX OR EQUIVALENT SE6000H-USRGM LOAD RATED DC DISCONNECT WITH AFCI, RAPID SHUTDOWN COMPLIANT 6000 WATT INVERTER E HANWHA Q-CELLS: Q.PEAK G4.1 305 (20) MODULES EXISTING SYSTEM PV MODULESE (N) (3) 60A ESS BREAKERS AT OPPOSITE END OF BUSBAR 2 CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 3/4" EMT OR EQUIV.(2) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 2 1" EMT OR EQUIV.(2) 3 AWG THHN/THWN-2 (1) 3 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 E EXISTING PV-4.0 ELECTRICAL #ESTAMP GENERAL NOTES: • CITY REQUIRES TWO SOURCES OF GROUND - UFER, TWO GROUNDS RODS OR COLD WATER GAS BOND • IF THE RELOCATED LOADS EXTEND MORE THAN 6 FEET, AFCI PROTECTION APPLIES PER 2019 CEC 210.12 • ANY MULTIWIRE BRANCH CIRCUITS RELOCATED ARE TO BE IDENTIFIED, GROUPED, AND EQUIPPED WITH A 2-POLE OCPD BREAKER PER CEC 210.4(B,D). • INSTALL THE BACKED UP LOAD CONDUCTORS AND THE GATEWAY BREAKER CONDUCTORS IN TWO SEPARATE CONDUITS. POWER CONTROL SYSTEM (PCS): • A PCS IS INSTALLED IN ACCORDANCE WITH NEC 705.13 • THE PCS SHALL LIMIT GENERATION SOURCE OUTPUT SUCH THAT CURRENT FROM ALL SOURCES OF SUPPLY DOES NOT EXCEED THE RATING OF ANY BUSBAR OR CONDUCTOR SUPPLIED BY THE POWER PRODUCTION SOURCES • ANY BUSBAR OR CONDUCTOR ON THE LOAD SIDE OF THE SERVICE DISCONNECT NOT MONITORED BY THE PCS SHALL COMPLY WITH ARTICLE 705.12. • ACCESS TO PCS CONTROLS IS RESTRICTED TO QUALIFIED PERSONS IN ACCORDANCE WITH 240.6(C). • INVERTER 1: (E) SOLAREDGE TECHNOLOGIES: SE6000H-USRGM 6000 WATT INVERTER • DO NOT ENABLE PCS • ENERGY STORAGE SYSTEM: TESLA: POWERWALL • ENABLE PCS SETPOINTS: - 80A - MAXIMUM TOTAL CURRENT ON THE CONTROLLED PANEL - 0A - FAIL SAFE GENERATION BACKFEED CURRENT SUPPLY (120% COMPLIANT) F