Loading...
HomeMy WebLinkAbout1915 W Trask Ave-REV 1 - PlanPAGE REV: C2 5/15/2025 VICTORIA HUYNH 1915 TRASK AVE, SANTA ANA,  CA, 92706 PROJECT NUMBER:   109R-915HUYN SHEET DESIGNER: NOORUDDIN AJAM CUSTOMER RESIDENCE: TEL. (714) 519-8517 APN: 101-042-29 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 COVER SHEET SCOPE OF WORK GENERAL NOTES PV-1.0 VICINITY MAP LTD: LR5-54HABB-395M TESLA: POWERWALL 3 1707000-XX-Y, (1) TESLA: POWERWALL 3 1707000-XX-Y SNR-DC-00339 1707000-XX-Y EQUIPMENT INSTALLED, SEE PV-4.0 FOR INTERCONNECTION DETAILS #SSTAMPCS #ESTAMPCS ABBREVIATIONS A AMPERE AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT (E)EXISTING ESS ENERGY STORAGE SYSTEM MSP MAIN SERVICE PANEL (N)NEW PRE-FAB PRE-FABRICATED PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS V VOLTS W WATTS SHEET INDEX MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.41(A). MODULES, ARE CLASS A FIRE RATED. CONDUCTORS OUTSIDE OF THE ARRAY ARE LIMITED TO LESS THAN 30V IN 30 SECONDS AND CEC 2022 690.12(B)(2)(2) WHERE CONDUCTORS INSIDE THE ARRAY BOUNDARY IS LIMITED TO LESS THAN 80V IN 30 SECONDS ROUTINE MAINTENANCE. SYSTEM VOLTAGE IN ACCORDANCE WITH CEC 706.20 AND EXCEPTION 1 CEC 706.20 (B). CIRCUITS FROM THESE TERMINALS PASS THROUGH A WALL OR PARTITION PER 706.15(D). CIRCUIT WIRING IS EXTENDED MORE THAN 6FT AND DOES NOT INCLUDE ANY ADDITIONAL OUTLETS OR DEVICES PER CEC 210.12(D). GREATER THAN THE LOAD POSED BY THE SINGLE LARGEST UTILIZATION EQUIPMENT CONNECTED TO THE SYSTEM PER CEC ARTICLE 710.15(A) PAGE # DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-2.1 ESS ELEVATION  DETAIL PV-3.0 LAYOUT PV-3.1 MOUNTING DETAIL PV-4.0 ELECTRICAL PV-4.1 ELECTRICAL CALCS PV-4.2 PANEL SCHEDULE PV-5.0 SIGNAGE PV-5.1 SIGNAGE C2 C2 Rev to 20185432 (issued on 4/25/25)REV 1 #20185939APPROVALS: ELECT - M. Smith /ce/ PAGE REV: C2 5/15/2025 VICTORIA HUYNH 1915 TRASK AVE, SANTA ANA,  CA, 92706 PROJECT NUMBER:   109R-915HUYN SHEET DESIGNER: NOORUDDIN AJAM CUSTOMER RESIDENCE: TEL. (714) 519-8517 APN: 101-042-29 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 PL PL PL PL PLPLPL PL PL PL PL PL PL PL SITE PLAN PV-2.0 #SSTAMPSP #ESTAMPSP POWERWALL ENERGY  STORAGE SYSTEM (ESS) BG BACKUP GATEWAY GP GENERATION PANEL ELECTRIC VEHICLE  SUPPLY EQUPMENTEV MAIN PANEL INVERTER(S) AC DISCONNECT(S) DC DISCONNECT(S) SUNRUN METER DEDICATED PV METER SERVICE ENTRANCE  INTERIOR EQUIPMENT  SHOWN AS DASHED SE MP SM PM INV AC DC SUB-PANELSP CB IQ COMBINER BOX METER ADAPTERMA GROUNDING  ELECTRODE ENERGY STORAGE  SYSTEM BP BACKUP LOADS PANEL BI BACKUP INTERFACE  1 COMMUNICATION  WIRESAM MD MICROGRID  INTERCONNECT DEVICE ACREL METER SOLAREDGE METERSEMPV LOAD CENTERLC LEGEND  SCALE: NTS NOTE: NOT ALL ITEMS IN LEGEND  WILL APPEAR IN SITE PLAN ARRAY  PITCH PV AREA  (SQFT) AR-01 19° 294.3 AR-02 22° 504.5270° TRUE  AZIM MAG  AZIM 168°180° 258° SITE PLAN - SCALE = 0'-0 3/64" = 1'-0" NOTES:  RESIDENCE DOES NOT CONTAIN ACTIVE FIRE  SPRINKLERS. ARRAY DETAILS:  TOTAL ROOF SURFACE AREA: 3491 SQFT.  TOTAL PV ARRAY AREA: 798.8 SQ FT.  PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE  AREA) * 100 = 22.9% RAIL STANDOFFS &  FOOTINGS SOLAR  MODULES ESS SHALL BE INSTALLED IN COMPLIANCE WITH  328.4 ESS INSTALLED ON THE EXTERIOR OF A  DWELLING UNIT SHALL NOT BE INSTALLED LESS  THAN THREE (3) FEET FROM DOORS AND  WINDOWS DIRECTLY ENTERING THE DWELLING  UNIT    (E) GATE ROOF PATHWAYS  (3' TYP) (N) ARRAY AR-02 INV INV    SE MP RSD MD (N) ARRAY AR-01 TRASK AVE (E) DETACHED  STRUCTURE ROOF PATHWAYS  (3' TYP) FIRE SETBACKS  (18" TYP)    INV (E) RESIDENCE AC AC AC A A A A A A A D D D D D D D B B B B B B C B B B B B C C C C C C C C C C C MAIN SERVICE  PANEL (N) CONDUIT RUN (N) RAPID  SHUTDOWN SWITCH FRONT DOOR EQUIPMENT ELEVATION DETAIL - SCALE = NTS NORTH EXTERIOR WALL WINDOW WINDOWDOOR TESLA  BACKUP  SWITCH B AC C2 C2 C2 C2 ACD Exp. 12/31/2026Digitally Signed On: 05/21/25 /ce/ PAGE REV: C2 5/15/2025 VICTORIA HUYNH 1915 TRASK AVE, SANTA ANA,  CA, 92706 PROJECT NUMBER:   109R-915HUYN SHEET DESIGNER: NOORUDDIN AJAM CUSTOMER RESIDENCE: TEL. (714) 519-8517 APN: 101-042-29 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 TESL TESL TESL  ESS ELEVATION  DETAIL PV-2.1 #SSTAMPSP #ESTAMPSP ESS ELEVATION DETAIL- SCALE = NTS 2X (PV+BATTERY) WINDOW GATE 1X (PV+BATTERY) ACDACDACD ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS IN ACCORDANCE WITH R328.4.  ESS UNITS SHALL BE SEPARATED FROM EACH  OTHER BY NOT LESS THAN 3 FEET EXCEPT WHERE SMALLER SEPARATION DISTANCES ARE DOCUMENTED TO BE ADEQUATE BASED ON  LARGE/SCALE FIRE TESTING. (N) CONDUIT RUN WINDOW WINDOW DOOR C2 Exp. 12/31/2026Digitally Signed On: 05/21/25 /ce/ PAGE REV: C2 5/15/2025 VICTORIA HUYNH 1915 TRASK AVE, SANTA ANA,  CA, 92706 PROJECT NUMBER:   109R-915HUYN SHEET DESIGNER: NOORUDDIN AJAM CUSTOMER RESIDENCE: TEL. (714) 519-8517 APN: 101-042-29 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 #SSTAMP DESIGN CRITERIA MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF WIND SPEED:  96 MPH 3-SEC GUST. FASTENERS: (1) 5/16" DIA UMBRELLA LAG  SCREW: 2.5" MIN EMBEDMENT  INTO FRAMING PV-3.0 LAYOUT EXISTING STRUCTURE IS ASSUMED TO BE  A LIGHT-FRAME WOOD ROOF AND FREE  FROM DAMAGE, DETERIORATION, OR  MODIFICATION THAT WOULD COMPROMISE  ITS ORIGINAL DESIGN INTEGRITY.  CONTACT ENGINEER OF RECORD IF  FOLLOWING MINIMUM REQUIREMENTS ARE  NOT SATISFIED IN COMPLIANCE WITH THE  STATED RACKING DESIGN: 4" SOLAR MODULE SNAPNRACK  RACKING MODULE ELEVATION DETAIL - SCALE: NTS INSTALLERS SHALL NOTIFY ENGINEER OF ANY  POTENTIAL STRUCTURAL ISSUES OBSERVED  PRIOR TO PROCEEDING W/ INSTALLATION. * IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12"  BOUNDARY REGION OF ANY ROOF PLANE  EDGES (EXCEPT VALLEYS), THEN  ATTACHMENTS NEED TO BE ADDED AND  OVERHANG REDUCED WITHIN THE 12"  BOUNDARY REGION ONLY AS FOLLOWS: ** ALLOWABLE ATTACHMENT SPACING  INDICATED ON PLANS TO BE REDUCED BY 50%. ** ALLOWABLE OVERHANG INDICATED ON  PLANS TO BE 1/5TH OF ALLOWABLE  ATTACHMENT SPACING INDICATED ON PLANS. D1 - AR-01 - SCALE: 0'-0 1/8" = 1'-0" AZIM: 180° PITCH: 19° D2 - AR-02 - SCALE: 0'-0 1/8" = 1'-0" AZIM: 270° PITCH: 22° ROOF INFO ATTACHMENT INFORMATION Name Type Height Detail Max Landscape  OC Spacing Max Landscape  Overhang Max Portrait  OC Spacing Max Portrait  Overhang Configuration AR-01 COMP SHINGLE - UMBRELLA L FOOT 1-Story ULTRA RAIL, ATTACHMENT DETAIL, UMBRELLA L FOOT TO FRAMING -  SNR-DC-00339 5'-4" 2'-1" 5'-4" 2'-1" STACKED AR-02 COMP SHINGLE -  UMBRELLA L FOOT 1-Story ULTRA RAIL, ATTACHMENT DETAIL, UMBRELLA L FOOT TO FRAMING - SNR-DC-00339 5'-4" 2'-1" 5'-4" 2'-1" STACKED 26'-5"7'-8"15'-1" 49'-2" 11'-4" 4'-7"2'-5" 6'-9" 2'-9" 2'-10" 4'-2" 4'-10" 26'-5" 11'-4" 12'-1"10'-1" 3'-4" 8'-1" 1'-6" 5'-9" 2" 5'-4" TYP 5'-4" TYP C2 C2 C2 C2 C2 Exp. 12/31/2026Digitally Signed On: 05/21/25 /ce/ MOUNTING DETAIL PV-3.1 PAGE REV: C2 5/15/2025 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 VICTORIA HUYNH 1915 TRASK AVE, SANTA ANA,  CA, 92706 PROJECT NUMBER:   109R-915HUYN SHEET DESIGNER: NOORUDDIN AJAM CUSTOMER RESIDENCE: TEL. (714) 519-8517 APN: 101-042-29 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 UR-40 RAIL | UR-60 RAIL FOR USE WITH SNAPNRACK ULTRA SERIES RAILS PENETRATION DETAIL INSTALLED SECTION VIEW DESIGNER:SCALE: DRAWING NUMBER: DESCRIPTION: APPROVED BY: REVISION: Sunrun South LLC 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA  94105  USA PHONE (415) 580-6900 ● FAX (415) 580-6902 THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY.  ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. ULTRA RAIL, ATTACHMENT DETAIL, UMBRELLASNR-DC-00339 L FOOT TO RAFTER 1 5/7/2019 NEW DETAIL 1 6/18/2019 DRO-00138 B 6/22/2023 DC002707 REV: BDATE: DNS 6/22/2023 DRAFTER:M.AFFENTRANGER E.FERGUSON M.AFFENTRANGER Solar Mounting Solutions MJA MJA MJA BIN: 8 214" 11 2" 11 2" 15 8" SNAPNRACK ULTRA RAIL UMBRELLA L FOOT WITH UMBRELLA FLASHING FOR COMPOSTION ROOF MOUNTING REFER TO SNAPNRACK ENGINEERING CHARTS FOR APPLICABLE RAIL SPANS. "BIN" NUMBER ON CHART SHOULD MATCH "BIN" NUMBER ON THIS DRAWING 5 16"Ø S.S. UMBRELLA LAG SCREW MUST EMBED A MIN. OF 212"INTO STRUCTURAL MEMBER TO UTILIZE STANDARD SNAPNRACK ENGINEERING. REACH OUT TO SNAPNRACK IF THIS IS NOT POSSIBLE REFER TO SNAPNRACK INSTALLATION MANUAL FOR 516"Ø HARDWARE TORQUE SPECIFICATIONS RAIL CAN BE MOUNTED ON EITHER SIDE OF THE L-FOOT FOR LEVELING DETAILS, REFER TO SNAPNRACK DETAIL DRAWING "SNR-DC-00447"   STRUCUTRAL MEMBER, WOOD RAFTER, TYP. ROOF DECKING, TYP. SNAPNRACK 5 16" LAG SCREW, S.S. COMP SHINGLE ROOFING, TYP. SNAPNRACK ULTRA RAIL SNAPNRACK UMBRELLA FLASHING 212"MIN. EMBEDMENT INTO WOOD MEMBER MODULE HEIGHT OFF ROOF: UR-40: 338"- 438" UR-60: 4" - 5" SNAPNRACK ULTRA RAIL UMBRELLA L FOOT STRUCUTRAL MEMBER, WOOD RAFTER, TYP. ROOF DECKING, TYP. COMP SHINGLE ROOFING, TYP. SNAPNRACK ULTRA RAIL UMBRELLA L FOOT WITH UMBRELLA LAG AND FLASHING SNAPNRACK UMBRELLA FLASHING C2 Exp. 12/31/2026Digitally Signed On: 05/21/25 EXISTING 200A MAIN BREAKER END FED EXISTING 225A MAIN PANEL 225A BUS J-BOX LONGI GREEN ENERGY TECHNOLOGY CO LTD LR5-54HABB-395M STRING 1 OF 7 MODULES 3  MODULE LEVEL RAPID SHUTDOWN DEVICES LONGI GREEN ENERGY TECHNOLOGY CO LTD LR5-54HABB-395M STRING 2 OF 7 MODULES 3  MODULE LEVEL RAPID SHUTDOWN DEVICES 1 1 2a POINT OF INTERCONNECTION:705.13, LOAD BREAKER AT OPPOSITE END OF BUSBAR METER NUMBER: 222013583969 EQUIPMENT CHARACTERISTICS INCLUDED IN SPEC SHEETS NOTE: TOTAL PV BACKFEED = 180A USED FOR INTERCONNECTION  CALCULATIONS BEFORE PCS APPLICATION (N) REMOTE DISABLE SWITCH LOVATO GAZ016UL 4X, 16A  ROTARY HANDLE TESLA POWERWALL 3 1707000-XX-Y TESLA: POWERWALL 3 1707000-XX-Y 11500 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT,POWER  CONTROL SYSTEM 3 TESLA POWERWALL 3 1707000-XX-Y TESLA: POWERWALL 3 1707000-XX-Y 11500 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT 3 TESLA POWERWALL 3 1707000-XX-Y TESLA: POWERWALL 3 1707000-XX-Y 11500 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT 3 (N) LOCKABLE BLADE TYPE AC  DISCONNECT SQUARE D DU222RB 3R, 60A , 2P 120/240VAC 3 J-BOX LONGI GREEN ENERGY TECHNOLOGY CO LTD LR5-54HABB-395M STRING 1 OF 12 MODULES 4  MODULE LEVEL RAPID SHUTDOWN DEVICES 12 J-BOX LONGI GREEN ENERGY TECHNOLOGY CO LTD LR5-54HABB-395M STRING 1 OF 12 MODULES 4  MODULE LEVEL RAPID SHUTDOWN DEVICES 12 1 1 60A 60A 60A M TESLA  BACKUP  SWITCH (N) LOCKABLE BLADE TYPE AC  DISCONNECT SQUARE D DU222RB 3R, 60A , 2P 120/240VAC 3 (N) LOCKABLE BLADE TYPE AC  DISCONNECT SQUARE D DU222RB 3R, 60A , 2P 120/240VAC 3 (N) LOCKABLE BLADE TYPE AC  DISCONNECT SQUARE D DU222RB 3R, 60A , 2P 120/240VAC 3 PAGE REV: C2 5/15/2025 VICTORIA HUYNH 1915 TRASK AVE, SANTA ANA,  CA, 92706 PROJECT NUMBER:   109R-915HUYN SHEET DESIGNER: NOORUDDIN AJAM CUSTOMER RESIDENCE: TEL. (714) 519-8517 APN: 101-042-29 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER 2 3/4" EMT OR EQUIV.(2) 10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2 2a 3/4" EMT OR EQUIV.(4) 10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV.(2) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 BACKUP LOADS LOAD BREAKER RATING  (AMPS)LABEL DEMAND LOAD(VA) 1 15A-1P DEN ROOM 1500 2 15A-1P LAUNDRY LIGHTS 1500 3 15A-1P FRIDGE 2 1500 4 15A-1P KITCHEN APPLIANCE 1500 5 15A-1P BEDROOM 1 LIGHTS 1500 6 15A-1P BEDROOM 2 LIGHTS 1500 7 15A-1P HALLWAY LIGHTS 1500 8 20A-1P MICROWAVE 1500 9 20A-1P FRIDGE 1 1500 10 20A-1P DISHWASHER 1500 11 20A-1P LAUNDRY OUTLETS 1500 12 20A-1P MASTER CLOSET 1500 13 20A-1P OUTDOOR LIGHTS 1500 14 20A-1P KICTCHEN ISLAND 1500 15 20A-1P BEDROOM 1 OUTLETS 1500 16 20A-1P BEDROOM 2 OUTLETS 1500 17 20A-1P LIVING OUTLETS 1500 18 20A-1P LIVING LIGHTS 1500 19 20A-1P KITCHEN OUTLETS 1500 20 15A-2P FURNACE 1 2880 21 20A-2P FURNACE 2 3840 22 30A-2P HEATER 5760 23 30A-2P AC 2 3840 24 30A-2P GARAGE 5760 25 35A-2P OVEN 6720 26 40A-2P AC 1 4560 PV-4.0 ELECTRICAL #ESTAMP GENERAL NOTES:  COLD WATER GAS BOND STRING VOLTAGE. ALL SINGLE POLE CIRCUITS MUST BE INSTALLED WITH AFCI PROTECTED  BREAKERS AS REQUIRED BY CEC 210.12(A). MODULE CHARACTERISTICS LONGI GREEN ENERGY  TECHNOLOGY CO LTD:  LR5-54HABB-395M 395 W OPEN CIRCUIT VOLTAGE 36.81 V MAX POWER VOLTAGE 30.7 V SHORT CIRCUIT CURRENT 14.79 A POWER CONTROL SYSTEM (PCS): SOURCES OF SUPPLY DOES NOT EXCEED THE RATING OF ANY BUSBAR OR CONDUCTOR  SUPPLIED BY THE POWER PRODUCTION SOURCES MONITORED BY THE PCS SHALL COMPLY WITH ARTICLE 705.12. WITH 240.6(C).  SETPOINTS:           - 180A - MAXIMUM TOTAL CURRENT ON THE CONTROLLED PANEL           - 0A - FAIL SAFE GENERATION BACKFEED CURRENT SUPPLY (120% COMPLIANT) C2 C2 C2 C2 PAGE REV: C2 5/15/2025 VICTORIA HUYNH 1915 TRASK AVE, SANTA ANA,  CA, 92706 PROJECT NUMBER:   109R-915HUYN SHEET DESIGNER: NOORUDDIN AJAM CUSTOMER RESIDENCE: TEL. (714) 519-8517 APN: 101-042-29 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 #ESTAMP SYSTEM INFORMATION 15.01 KW DC PHOTOVOLTAIC SYSTEM      (14) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-395M, TESLA: POWERWALL 3 1707000-XX-Y      (12) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-395M, TESLA: POWERWALL 3 1707000-XX-Y      (12) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-395M, TESLA: POWERWALL 3 1707000-XX-Y ALLOWABLE BACKFEED MAX ALLOWED TOTAL GENERATION BACKFEED OCPD = MAIN BREAKER RATING = 200A 180A ≤ 200A→ INTERCONNECTION MEETS 705.13 REQUIREMENTS. SYSTEM OCPD SIZE (COMBINED MAX CURRENT) X (CONTINUOUS LOAD) =  48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION 48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION 48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION INVERTER INFORMATION 5530 KW DC PHOTOVOLTAIC SYSTEM      (14) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-395M, TESLA: POWERWALL 3 1707000-XX-Y INVERTER OVERCURRENT PROTECTION (INVERTER MAX CURRENT) X (CONTINUOUS LOAD) =  48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION PER MANUFACTURER DC WIRE SIZING MAX CIRCUIT CURRENT = (MODULE ISC) X (HIGH IRRADIANCE)[690.8(A)(1)] X (CONTINUOUS LOAD)[690.8(B)(1)]=  15A X 1.25 = 18.75A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X  (CONDUCTOR AMPACITY)[TABLE 310.16] =  0.91 X 0.8 X 40A = 29.12A TERMINAL RATING[110.14(C)] = 10 AWG,  RATED = 35A 29.12A < 35A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. 18.75A < 35A → 10 AWG AMPACITY OK THEREFORE 10 AWG IS SUFFICIENT. AC WIRE SIZING MAX AC OUTPUT CURRENT = (MAX INVERTER OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] = 48 A X 1.25 = 60 A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X  (CONDUCTOR AMPACITY)[TABLE 310.16] =  0.91 X 0.8 X 75A = 81.25A TERMINAL RATING[110.14(C)] = 6 AWG,  RATED = 65A 65A < 81.25A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. 60A < 65A → 6 AWG AMPACITY OK THEREFORE 6 AWG IS SUFFICIENT. SYSTEM CHARACTERISTICS MAX OPEN CIRCUIT VOLTAGE   = [((TEMP COEF VOC) X (VOC)) / 100] X [LOW TEMP - STC TEMP] + VOC X (#  MODULES / STRING) = [(-0.26 %/°C X 36.81 V) / 100] X [-2 °C - 25 °C] + 36.81 V X 7 = 276 V SHORT CIRCUIT CURRENT = 1.25 X (MODULE ISC) X (# STRINGS) 1.25 X 14.79 A X 2 = 36.97A INVERTER INFORMATION 4740 KW DC PHOTOVOLTAIC SYSTEM      (12) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-395M, TESLA: POWERWALL 3 1707000-XX-Y INVERTER OVERCURRENT PROTECTION (INVERTER MAX CURRENT) X (CONTINUOUS LOAD) =  48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION PER MANUFACTURER DC WIRE SIZING MAX CIRCUIT CURRENT = (MODULE ISC) X (HIGH IRRADIANCE)[690.8(A)(1)] X (CONTINUOUS  LOAD)[690.8(B)(1)]=  15A X 1.25 = 18.75A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT  FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  0.91 X 1 X 40A = 36.4A TERMINAL RATING[110.14(C)] = 10 AWG,  RATED = 35A 35A < 36.4A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. 18.75A < 35A → 10 AWG AMPACITY OK THEREFORE 10 AWG IS SUFFICIENT. AC WIRE SIZING MAX AC OUTPUT CURRENT = (MAX INVERTER OUTPUT) X (CONTINUOUS  LOAD)[210.19(A)(1)] = 48 A X 1.25 = 60 A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT  FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  0.91 X 0.8 X 75A = 81.25A TERMINAL RATING[110.14(C)] = 6 AWG,  RATED = 65A 65A < 81.25A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. 60A < 65A → 6 AWG AMPACITY OK THEREFORE 6 AWG IS SUFFICIENT. SYSTEM CHARACTERISTICS MAX OPEN CIRCUIT VOLTAGE   = [((TEMP COEF VOC) X (VOC)) / 100] X [LOW TEMP - STC  TEMP] + VOC X (# MODULES / STRING) = [(-0.26 %/°C X 36.81 V) / 100] X [-2 °C - 25 °C] + 36.81 V X 12 = 473 V SHORT CIRCUIT CURRENT = 1.25 X (MODULE ISC) X (# STRINGS) 1.25 X 14.79 A X 1 = 18.48A INVERTER INFORMATION 4740 KW DC PHOTOVOLTAIC SYSTEM      (12) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-395M, TESLA:  POWERWALL 3 1707000-XX-Y INVERTER OVERCURRENT PROTECTION (INVERTER MAX CURRENT) X (CONTINUOUS LOAD) =  48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION PER MANUFACTURER DC WIRE SIZING MAX CIRCUIT CURRENT = (MODULE ISC) X (HIGH IRRADIANCE)[690.8(A)(1)] X (CONTINUOUS  LOAD)[690.8(B)(1)]=  15A X 1.25 = 18.75A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT  FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  0.91 X 1 X 40A = 36.4A TERMINAL RATING[110.14(C)] = 10 AWG,  RATED = 35A 35A < 36.4A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. 18.75A < 35A → 10 AWG AMPACITY OK THEREFORE 10 AWG IS SUFFICIENT. AC WIRE SIZING MAX AC OUTPUT CURRENT = (MAX INVERTER OUTPUT) X (CONTINUOUS  LOAD)[210.19(A)(1)] = 48 A X 1.25 = 60 A ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT  FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  0.91 X 0.8 X 75A = 81.25A TERMINAL RATING[110.14(C)] = 6 AWG,  RATED = 65A 65A < 81.25A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. 60A < 65A → 6 AWG AMPACITY OK THEREFORE 6 AWG IS SUFFICIENT. SYSTEM CHARACTERISTICS MAX OPEN CIRCUIT VOLTAGE   = [((TEMP COEF VOC) X (VOC)) / 100] X [LOW TEMP - STC  TEMP] + VOC X (# MODULES / STRING) = [(-0.26 %/°C X 36.81 V) / 100] X [-2 °C - 25 °C] + 36.81 V X 12 = 473 V SHORT CIRCUIT CURRENT = 1.25 X (MODULE ISC) X (# STRINGS) 1.25 X 14.79 A X 1 = 18.48A PV-4.1 ELECTRICAL CALCS C2 C2 PAGE REV: C2 5/15/2025 VICTORIA HUYNH 1915 TRASK AVE, SANTA ANA,  CA, 92706 PROJECT NUMBER:   109R-915HUYN SHEET DESIGNER: NOORUDDIN AJAM CUSTOMER RESIDENCE: TEL. (714) 519-8517 APN: 101-042-29 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 #ESTAMP PV-4.2 PANEL  SCHEDULE EXISTING 225/200A  MAIN PANEL 200 FUTURE 225A MAIN  PANEL 20 1 5 20 20 30 20 20 20 20 40 20 15 15 20 20 15 15 15 30 15 15 30 2 0 20 35 AC 1 OVEN GARAGE HEATER AC 2 FURNACE 2 FURNACE 1 MICROWAVE FRIDGE 1 FRIDGE 2 DEN ROOM DISHWASHER LAUNDRY OUT CLOSET OUTDOOR LIGHTS ISLAND BED 1 OUT BED 2 OUT LIVING OUT LIVING LIG LAUNDRY LIGHTS HALL LIGHTS KITCHEN APPLIANCE BED 1 LIGHTS BED 2 LIGHTS 20KIT OUTLET PANEL SCHEDULE C2 200 20 1 5 20 20 30 20 20 20 20 40 20 15 15 20 20 15 15 15 30 15 15 30 2 0 20 35 AC 1 OVEN GARAGE HEATER AC 2 FURNACE 2 FURNACE 1 MICROWAVE FRIDGE 1 FRIDGE 2 DEN ROOM DISHWASHER LAUNDRY OUT CLOSET OUTDOOR LIGHTS ISLAND BED 1 OUT BED 2 OUT LIVING OUT LIVING LIG LAUNDRY LIGHTS HALL LIGHTS KITCHEN APPLIANCE BED 1 LIGHTS BED 2 LIGHTS 20KIT OUTLET 40 40 40 (N) 60A  PV+ESS  BREAKER (N) 60A  PV+ESS  BREAKER (N) 60A  PV+ESS  BREAKER 40A ESS breakers are to be 60A. MSmith(19) PAGE REV: C2 5/15/2025 VICTORIA HUYNH 1915 TRASK AVE, SANTA ANA,  CA, 92706 PROJECT NUMBER:   109R-915HUYN SHEET DESIGNER: NOORUDDIN AJAM CUSTOMER RESIDENCE: TEL. (714) 519-8517 APN: 101-042-29 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 SIGNAGE PV-5.0 #ESTAMP ENERGY STORAGE SYSTEM  DISCONNECT LABEL LOCATION: ENERGY STORAGE SYSTEM DISCONNECT PER CODE(S): NEC 2020: 706.15(C), CEC 2022: 706.15(C) MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE:           144 AMPS   240     VAC LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF  INTERCONNECTION. PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54 PV SYSTEM DISCONNECT WARNING! DO NOT RELOCATE THIS  OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS  OCPD (IF APPLICABLE). PER CODE(S): NEC 2020: 705.12(B)(3)(2),  CEC 2022: 705.12(B)(3)(2) NOTES AND SPECIFICATIONS:   SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF  THE CEC 2022 ARTICLE 110.21(B), UNLESS SPECIFIC  INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF  REQUESTED BY THE LOCAL AHJ.  SIGNS AND LABELS SHALL ADEQUATELY WARN OF  HAZARDS USING EFFECTIVE WORDS, COLORS AND  SYMBOLS.  LABELS SHALL BE PERMANENTLY AFFIXED TO THE  EQUIPMENT OR WIRING METHOD AND SHALL NOT BE  HAND WRITTEN.  LABEL SHALL BE OF SUFFICIENT DURABILITY TO  WITHSTAND THE ENVIRONMENT INVOLVED.  SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,  PRODUCT SAFETY SIGNS AND LABELS, UNLESS  OTHERWISE SPECIFIED.  DO NOT COVER EXISTING MANUFACTURER LABELS. SOLAR PV SYSTEM EQUIPPED  WITH RAPID SHUTDOWN SOLAR ELECTRIC  PV PANELS TURN RAPID SHUTDOWN  SWITCH TO THE "OFF"  POSITION TO SHUT DOWN  PV SYSTEM AND REDUCE  SHOCK HAZARD IN THE  ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE  DISCONNECTING MEANS TO WHICH THE PV SYSTEMS  ARE CONNECTED. PER CODE(S): NEC 2020: 690.56(C), CEC 2022: 690.56(C) 4" 3" ELECTRICAL SHOCK HAZARD WARNING TERMINALS ON LINE AND LOAD  SIDES MAY BE ENERGIZED IN  THE OPEN POSITION LABEL LOCATION: INVERTER(S),  AC/DC DISCONNECT(S),  AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020: 690.13(B), CEC  2022: 690.13(B) ! INVERTER 1 PHOTOVOLTAIC DC DISCONNECT MAXIMUM SYSTEM VOLTAGE:VDC550 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53 WARNING: PHOTOVOLTAIC  POWER SOURCE WARNING: PHOTOVOLTAIC  POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,  AT EACH TURN, ABOVE AND BELOW  PENETRATIONS,  ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2020: 690.31(D)(2), CEC 2022:  690.31(D)(2)CAUTION  1915 TRASK AVE, SANTA ANA, CA, 92706 PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10 MULTIPLE SOURCES OF POWER LABEL LOCATION: INSTALLED WITHIN 3' OF RAPID SHUT DOWN  SWITCH PER CODE(S): NEC 2020: 690.56(C)(2),  CEC 2022: 690.56(C)(2), IFC 2018: 1204.5.3 RAPID SHUTDOWN SWITCH  FOR SOLAR PV SYSTEM WARNING! SOURCES: UTILITY GRID,  BATTERY AND PV SOLAR  ELECTRIC SYSTEM THREE POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN  SERVICE PANEL. PER CODE(S): NEC 2020: 705.12(C), CEC  2022: 705.12(C) THIS EQUIPMENT FED BY  MULTIPLE SOURCES. TOTAL  RATING OF ALL OVERCURRENT  DEVICES EXCLUDING MAIN  SUPPLY OVERCURRENT DEVICE  SHALL NOT EXCEED AMPACITY OF  BUSBAR WARNING! LABEL LOCATION: PV LOAD CENTER (IF APPLICABLE) AND  ANY PANEL THAT UTILIZES "THE SUM  OF BREAKERS RULE". PER CODE(S): NEC 2020: 705.12 (B)(3)(3),  CEC 2022: 705.12 (B)(3)(3) ENERGY STORAGE SYSTEM PREMISES WIRING MAY REMAIN  ENERGIZED AFTER LOSS OF  UTILITY POWER CAUTION! LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2022: 706.15(C), NEC 2020: 706.15(C) SERVICE ENTRANCE AND TESLA BACKUP  SWITCH INVERTER+ENERGY  STORAGE (EXT)-PCS  CONTROLLED RAPID SHUTDOWN  SWITCH (EXT) SOLAR PANELS  ON ROOF AC DISCONNECT AC DISCONNECT C2 C2 PAGE REV: C2 5/15/2025 VICTORIA HUYNH 1915 TRASK AVE, SANTA ANA,  CA, 92706 PROJECT NUMBER:   109R-915HUYN SHEET DESIGNER: NOORUDDIN AJAM CUSTOMER RESIDENCE: TEL. (714) 519-8517 APN: 101-042-29 (415) 580-6920 ex3 Template_version_v5_2024 02 28 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603   FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 SIGNAGE PV-5.1 #ESTAMP WARNING: THIS SENSOR IS PART  OF A POWER CONTROL SYSTEM.  DO NOT REMOVE. REPLACE ONLY  WITH THE SAME TYPE AND RATING. WARNING: THIS SENSOR IS PART  OF A POWER CONTROL SYSTEM.  DO NOT REMOVE. REPLACE ONLY  WITH THE SAME TYPE AND RATING. REQUIREMENT: UL 1741, SECTION 206.3 LOCATION: AROUND THE CT WIRE  BY CLAMP SIZE 4.25" X 0.75" INVERTER 1 LABEL LOCATION: REQUIREMENT: UL 1741, SECTION 206.1 AND 206.4 LOCATION: MAIN PANEL SIZE: 4.25" X 1.25" PCS CONTROLLED CURRENT SETTING:  180 A   THE MAXIMUM OUTPUT CURRENT FROM THIS SYSTEM IS CONTROLLED ELECTRONICALLY. REFER TO THE MANUFACTURER'S INSTRUCTIONS FOR MORE INFORMATION. LABEL LOCATION: BACKED UP LOADS PANEL NO ADDITIONAL LOADS TO  BE ADDED C2