Loading...
HomeMy WebLinkAbout2221 N Heliotrope Dr - PlanNOTE: NO PROPOSED CHANGES TO FOOTPRINT OF (E) HOME, OTHER (E) STRUCTURES, OR LANDSCAPING. HELIOTROPE DRIVE SA N T A C L A R A A V E N U E (E) 1 STORY GARDEN ROOM - NOT IN SCOPE (E) 2 STORY SINGLE FAMILY RESIDENCE - NOT IN SCOPE (E) POOL HOUSE - NOT IN SCOPE (E) DRIVEWAY (E ) W A L K W A Y 90° 00' 00" 224.00' N W 0° 32' 45" 166.51' S W 0° 0 0 ' 0 0 " 16 3 . 6 6 ' S W 83° 31' 34" 202.99'S W 50° 00' 08" 31.19' S E (N) GAZEBO/PAVILION, 205 SQ FT APPROX. 38.00 15 . 0 0 12.00 (E) STUCCO WALL, 6 FEET TALL NOTE: DIMENSIONS ARE FROM PROPERTY LINE TO OUTSIDE EDGE OF ROOF OVERHANG (E) LANDSCAPING BEHIND WALL TO BE MAINTAINED FOR SCREENING AP P R O X . 3 0 SCALE: DATE: NO. ISSUES: DATE DESCRIPTION OWNERS: DR. CHAN KIEU & DR. QUYNH KIEU 2221 N. HELIOTROPE DR SANTA ANA, CA 92706 ARCHITECT: QUENTIN STANTON ARCHITECTURE 3712 CROWN POINT DR SAN DIEGO, CA 92109 (619)985-8822 Q@QSTANTON.COM STRUCTURAL ENGINEER: TUNG THANH VO, M.S., P.E. 11122 BIXLER CIR. GARDEN GROVE, CA 92840 (714)928-2006 TUNGCIVIL2018@GMAIL.COM HELIOTROPE PAVILION 2221 N. HELIOTROPE DR SANTA ANA, CA 92706 SHEET TITLE: SHEET NUMBER: 05/18/25 1ST SUBMISSION 10/27/25 2ND SUBMISSION1 12/16/25 3RD SUBMISSION2 1" = 20'-0" 12/16/2025 3:02:44 PM G000 COVER SHEET 12/16/2025 SHEET LIST - ARCHITECTURAL G000 COVER SHEET G100 SITE ELEVATION A101 FLOOR PLAN, SECTION & ELEVATION A110 TYP SLAB DETAILS & ICC-ES REPORT A111 ICC-ES REPORT CONT'D CONSTRUCTION OF A NEW 205 SF DETACHED 2 STORY HIGH MOON PAVILION/GAZEBO. NO CHANGE TO (E) HOME OR OTHER (E) STRUCTURES ON THE PROPERTY. SCOPE OF WORK PROJECT ADDRESS: 2221 N. HELIOTROPE DR SANTA ANA, CA 92706 ASSESSORS PARCEL NUMBERS: 002-081-45 AND 002-081-46 LEGAL DESCRIPTION:TR 1035 LOT 17, LOT 18 AND LOT 19 GENERAL PLAN LAND USE DESIGNATION: LR 7.0 ZONING DISTRICT: R1 TOTAL LOT SIZE: 39,547 SF (0.908 ACRES) HISTORIC PROPERTY:YES HISTORIC DISTRICT:NO TYPE OF CONSTRUCTION: V-B - NON-SPRINKLERED PROPOSED NUMBER OF STORIES: 2 PROPOSED STRUCTURE HEIGHT:22' - 8" OCCUPANCY OF PROPOSED BUILDING: U (ACCESSORY STRUCTURE) OCCUPANCY OF EXISTING STRUCTURES:R-3 PROPOSED EXTERIOR WALL AND ROOF MATERIALS: WALL:N/A, NOT ENCLOSED ROOF: TILE EXISTING BUILDINGS EXTERIOR WALL AND ROOF MATERIALS: WALL: STUCCO ROOF: ASPHALT SHINGLE GOVERNING CODES: 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA GREEN BUILDING CODE (CALGREEN) AHJ AND LOCAL CODES AND NFPA CONTRACTOR:TO BE DETERMINED N 2221 N HELIOTROPE DR NOT TO SCALE LEGEND OF PROJECT DATA DRAWING INDEX VICINITY MAP SITE PLAN / PLOT PLAN OWNERS' NAME AND ADDRESS: DR. CHAN KIEU & DR. QUYNH KIEU 2221 N. HELIOTROPE DR SANTA ANA, CA 92706 ARCHITECT / APPLICANT'S NAME AND ADDRESS: QUENTIN STANTON, RA QUENTIN STANTON ARCHITECTURE 619-985-8822 Q@QSTANTON.COM 3712 CROWN POINT DRIVE SAN DIEGO, CA 92109 STRUCTURAL ENGINEER: TUNG THANH VO, M.S., P.E. 714-928-2006 TUNGCIVIL2018@GMAIL.COM 11122 BIXLER CIR. GARDEN GROVE, CA 92840 PROJECT TEAM NN TRUEPROJECT 1" = 20'-0"2 SITE PLAN SHEET LIST - STRUCTURAL S0.0 GENERAL STRUCTURAL NOTES S1.0 FOUNDATION PLAN, FRAMING PLAN & DETAILS 2 12/16/2025 04/30/2027 DIGITALLY STAMPED/SIGNED ON GRADE 0' -0" PAVILION ROOF PEAK 22' -8" (N) PAVILION - SEE SITE PLAN FOR EXACT LOCATION BEHIND HOME (E) STUCCO WALL, 6 FEET TALL APPROX. TOP OF (E) HOME 25' -0" NOTE: EXISTING HOME SHOWN FOR MASSING AND SCALE PURPOSES ONLY - ADDITIONAL ARCHITECTURAL DETAILS NOT SHOWN NOTE: HEIGHT OF EXISTING HOME IS SHOWN APPROXIMATELY FOR SCALE SCALE: DATE: NO. ISSUES: DATE DESCRIPTION OWNERS: DR. CHAN KIEU & DR. QUYNH KIEU 2221 N. HELIOTROPE DR SANTA ANA, CA 92706 ARCHITECT: QUENTIN STANTON ARCHITECTURE 3712 CROWN POINT DR SAN DIEGO, CA 92109 (619)985-8822 Q@QSTANTON.COM STRUCTURAL ENGINEER: TUNG THANH VO, M.S., P.E. 11122 BIXLER CIR. GARDEN GROVE, CA 92840 (714)928-2006 TUNGCIVIL2018@GMAIL.COM HELIOTROPE PAVILION 2221 N. HELIOTROPE DR SANTA ANA, CA 92706 SHEET TITLE: SHEET NUMBER: 05/18/25 1ST SUBMISSION 10/27/25 2ND SUBMISSION1 12/16/25 3RD SUBMISSION2 1/8" = 1'-0" 12/16/2025 3:02:44 PM G100 SITE ELEVATION 12/16/2025 1/8" = 1'-0"1 WEST SITE ELEVATION FROM HELIOTROPE - SHOWN WITH (E) HOME 04/30/2027 DIGITALLY STAMPED/SIGNED ON 12/16/2025 A101 3 2 A101 TYP. CONCRETE SLAB ON GRADE LINE OF ROOF ABOVE TYP - CONCRETE EXPANSION JOINTS / CONTRACTION JOINTS, SEE DETAIL ON A110 2% SLOPE2% SLOPE TYP - WEATHERPROOF GFCI ELECTICAL OUTLET, SURFACE MOUNT BOX AND CONDUIT, CENTERLINE OF JBOX TO BE 16" A.F.F. 15' - 4 3/4" TYP. 8' - 10 3/4"TYP. 6' - 0" 17 ' - 9 1 / 4 " A101 4 MOUNT DIRECTIONAL EXTERIOR LIGHT FIXTURE ABOVE ELECTRICAL OUTLET, CENTERLINE OF FIXTURE TO BE 24" A.F.F. MOUNT DIRECTIONAL EXTERIOR LIGHT FIXTURE ABOVE ELECTRICAL OUTLET, CENTERLINE OF FIXTURE TO BE 24" A.F.F. 2% S L O P E 2% S L O P E GRADE 0' -0" PAVILION ROOF PEAK 22' -8" SEE STRUCT DWG'S FOR FOUNDATION DESIGN AND OTHER DETAILING PREFABRICATED WOOD PAVILION 5' - 1 0 3 / 4 " 3' - 9 1 / 4 " 6' - 0 3 / 4 " 6' - 1 1 1 / 4 " THREE (3) DIRECTIONAL EXTERIOR LIGHT FIXTURES (FOR ACCENT LIGHTING), MOUNTED TO TOP OF BEAMS AT FIRST TIER OF ROOFING. LIGHT TO BE DIRECTED UPWARDS TO UNDERSIDE OF ROOF. BRAVA ROOF TILE - SEE SHEETS A110 AND A111 FOR CURRENT ICC-ES REPORT (NUMBER ESR-4756) GRADE 0' -0" PAVILION ROOF PEAK 22' -8"NOTE: PAVILION DESIGN IS THE SAME ON ALL ELEVATIONS (N, S, E, W). ELEVATION SHOWN IN THIS DRAWING IS TYPICAL FOR ALL SIDES. SEE STRUCT DWG'S FOR FOUNDATION DESIGN AND OTHER DETAILING PREFABRICATED WOOD PAVILION BRAVA ROOF TILE - SEE SHEETS A110 AND A111 FOR CURRENT ICC-ES REPORT (NUMBER ESR-4756) GRADE 0' -0" PAVILION ROOF PEAK 22' -8"NOTE: PAVILION DESIGN IS THE SAME ON ALL ELEVATIONS (N, S, E, W). ELEVATION SHOWN IN THIS DRAWING IS TYPICAL FOR ALL SIDES. SEE STRUCT DWG'S FOR FOUNDATION DESIGN AND OTHER DETAILING PREFABRICATED WOOD PAVILION BRAVA ROOF TILE - SEE SHEETS A110 AND A111 FOR CURRENT ICC-ES REPORT (NUMBER ESR-4756) 5' - 8 1/2" 11 3/4" 12' - 8 1/4" 10' - 9 1/2" 15 ' - 0 1 / 4 " SCALE: DATE: NO. ISSUES: DATE DESCRIPTION OWNERS: DR. CHAN KIEU & DR. QUYNH KIEU 2221 N. HELIOTROPE DR SANTA ANA, CA 92706 ARCHITECT: QUENTIN STANTON ARCHITECTURE 3712 CROWN POINT DR SAN DIEGO, CA 92109 (619)985-8822 Q@QSTANTON.COM STRUCTURAL ENGINEER: TUNG THANH VO, M.S., P.E. 11122 BIXLER CIR. GARDEN GROVE, CA 92840 (714)928-2006 TUNGCIVIL2018@GMAIL.COM HELIOTROPE PAVILION 2221 N. HELIOTROPE DR SANTA ANA, CA 92706 SHEET TITLE: SHEET NUMBER: 05/18/25 1ST SUBMISSION 10/27/25 2ND SUBMISSION1 12/16/25 3RD SUBMISSION2 1/4" = 1'-0" 12/16/2025 3:02:45 PM A101 FLOOR PLAN, SECTION & ELEVATION 12/16/2025 1/4" = 1'-0"1 FLOOR PLAN MECHANICAL/ELECTICAL/PLUMBING: - NO MECH OR PLUMBING WORK PROPOSED. - PROVIDE TWO GFCI ELECTRICAL RECEPTACLES IN WEATHERPROOF ENCLOSURE. SEE FLOOR PLAN. NN TRUEPROJECT 1/4" = 1'-0"2 SECTION N/S 1/4" = 1'-0"3 ELEVATION - TYP NOTE: - VERIFY DIMENSIONS OF PRECUT MEMBERS BEFORE FOUNDATION WORK (OR ANY OTHER WORK THAT RELIES ON FIT OR ALIGNMENT WITH PRECUT MEMBERS). 1/4" = 1'-0"4 ELEVATION - TYP (COLORED) LIGHTING: - PROVIDE TIMER FOR LIGHTING, AUTO SHUTOFF OF PAVILION LIGHTING TO OCCUR PER ZONING REQUIREMENTS. - ALL LIGHTS TO BE LED, 2700 OR 3000 KELVIN COLOR TEMPERATURE, MAX 800 LUMENS PER FIXTURE. 2 2 2 12/16/2025 04/30/2027 DIGITALLY STAMPED/SIGNED ON PROVIDE CONC. SEALER @ TOP TOOLED OR SAW CUT JOINT MIN. 3/4" SLAB DEPTH REINFORCING PER STRUCT. CONCRETE SLAB PER STRUCT. 10 MIL VAPOR RETARDER @ CONDITIONED SPACES CONTRACTION JOINT AT 4'-0" O.C. MAX. A EXPANSION JOINT AT 20'-0" O.C. MAX.B CONTRACTION JOINT (BETWEEN POURS) C ISOLATION JOINT -OUTDOOR AREAS ONLY: NON-INTERIOR D PROVIDE CONC. SEALER @ TOP SEALANT W/ BOND BREAKER REINFORCING STOP @ JOINT CONCRETE SLAB PER STRUCT. 10 MIL VAPOR RETARDER @ CONDITIONED SPACES EXPANSION JOINT MATERIAL REBAR PER STRUCT. COATED TO PREVENT BOND PROVIDE CONC. SEALER @ TOP REBAR PER STRUCT. COATED TO PREVENT BOND REINFORCING-STOP @ JOINT PER STRUCT. CONCRETE SLAB PER STRUCT. 10 MIL VAPOR RETARDER @ CONDITIONED SPACES PROVIDE CONC. SEALER @ TOP REINFORCING PER STRUCT. SEALANT W/BOND BREAKER EXPANSION JOINT MATERIAL CONCRETE SLAB PER STRUCT. 4" OF 1/2" OR LARGER CLEAN GRANULAR FILL 4" OF 1/2" OR LARGER CLEAN GRANULAR FILL 4" OF 1/2" OR LARGER CLEAN GRANULAR FILL 4" OF 1/2" OR LARGER CLEAN GRANULAR FILL NOTE: CONCRETE TO SLOPE 2% TOWARDS EDGE OF SLAB, TYP. SCALE: DATE: NO. ISSUES: DATE DESCRIPTION OWNERS: DR. CHAN KIEU & DR. QUYNH KIEU 2221 N. HELIOTROPE DR SANTA ANA, CA 92706 ARCHITECT: QUENTIN STANTON ARCHITECTURE 3712 CROWN POINT DR SAN DIEGO, CA 92109 (619)985-8822 Q@QSTANTON.COM STRUCTURAL ENGINEER: TUNG THANH VO, M.S., P.E. 11122 BIXLER CIR. GARDEN GROVE, CA 92840 (714)928-2006 TUNGCIVIL2018@GMAIL.COM HELIOTROPE PAVILION 2221 N. HELIOTROPE DR SANTA ANA, CA 92706 SHEET TITLE: SHEET NUMBER: 05/18/25 1ST SUBMISSION 10/27/25 2ND SUBMISSION1 12/16/25 3RD SUBMISSION2 As indicated 12/16/2025 3:02:47 PM A110 TYP SLAB DETAILS & ICC-ES REPORT 12/16/2025 1" = 1'-0"1 CONCRETE JOINTS2ROOF TILE ICC REPORT 2 12/16/2025 04/30/2027 DIGITALLY STAMPED/SIGNED ON SCALE: DATE: NO. ISSUES: DATE DESCRIPTION OWNERS: DR. CHAN KIEU & DR. QUYNH KIEU 2221 N. HELIOTROPE DR SANTA ANA, CA 92706 ARCHITECT: QUENTIN STANTON ARCHITECTURE 3712 CROWN POINT DR SAN DIEGO, CA 92109 (619)985-8822 Q@QSTANTON.COM STRUCTURAL ENGINEER: TUNG THANH VO, M.S., P.E. 11122 BIXLER CIR. GARDEN GROVE, CA 92840 (714)928-2006 TUNGCIVIL2018@GMAIL.COM HELIOTROPE PAVILION 2221 N. HELIOTROPE DR SANTA ANA, CA 92706 SHEET TITLE: SHEET NUMBER: 05/18/25 1ST SUBMISSION 10/27/25 2ND SUBMISSION1 12/16/25 3RD SUBMISSION2 1/8" = 1'-0" 12/16/2025 3:02:48 PM A111 ICC-ES REPORT CONT'D 12/16/2025 1 ROOF TILE ICC REPORT COT'D 2 12/16/2025 04/30/2027 DIGITALLY STAMPED/SIGNED ON STRUCTURAL STEEL REINFORCED CONCRETE WOOD CONCRETE MASONRY GENERAL REQUIREMENTS 1.IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY ALL GRADES, DIMENSIONS, ELEVATIONS AND CONDITIONS AT THE JOB SITE PRIOR TO BIDDING AND COMMENCING CONSTRUCTION. CROSS CHECK ALL DETAILS AND DIMENSIONS SHOWN ON THE STRUCTURAL DRAWINGS WITH RELATED REQUIREMENTS ON THE ARCHITECTURAL, ELECTRICAL, MECHANICAL, AND CIVIL DRAWINGS AND NOTIFY THE ENGINEER AND THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING WORK. 2.EXCEPT WHERE MORE STRINGENT REQUIREMENTS ARE NOTED OR SHOWN IN THE PLANS OR SPECIFICATIONS, ALL PHASES OF WORKMANSHIP AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE BUILDING CODE, LATEST ADDITION, AS WELL AS ALL APPLICABLE STATE AND LOCAL ORDINANCES AS ADOPTED BY THE CONTROLLING JURISDICTION. 3.THE CONTRACT DRAWINGS REPRESENT THE FINISHED STRUCTURE AND DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE STRUCTURE SHOWN ON THESE DRAWINGS IS STRUCTURALLY SOUND ONLY IN THE COMPLETED FORM. GENERAL CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE, WORKMEN, AND OTHER PERSONS DURING CONSTRUCTION. SUCH MEASURES INCLUDE, BUT ARE NOT LIMITED TO; BRACING, SHORING FOR CONSTRUCTION EQUIPMENT,AND SHORING FOR THE STRUCTURE. 4.TIN NO CASE SHALL DIMENSIONS BE SCALED FROM DRAWINGS AND/OR DETAILS. ANY DISCREPANCIES FOUND WITHIN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND ENGINEER FOR CLARIFICATION PRIOR TO PROCEEDING. ANY WORK INSTALLED PRIOR TO AND/OR IN CONFLICT WITH SUCH CLARIFICATION SHALL BE CORRECTED BY THE CONTRACTOR AT HIS EXPENSE AND AT NO ADDITIONAL COST TO THE OWNER. 5.THE PRECISE DIMENSIONS AND LOCATIONS OF ALL DOOR AND WINDOW OPENINGS, INTERIOR AND EXTERIOR WALLS SHALL BE DETERMINED FROM THE ARCHITECTURAL DRAWINGS. OTHER FLOOR, WALL AND ROOF OPENINGS AS REQUIRED FOR MECHANICAL, ELECTRICAL AND/OR SIMILAR REQUIREMENTS SHALL BE VERIFIED FROM SHOP DRAWINGS, EQUIPMENT DATA, ETC. AS REQUIRED. 6.FLOOR AND WALL OPENINGS, SLEEVES, VARIATIONS IN STRUCTURAL SLAB ELEVATIONS, DEPRESSED AREAS, AND ALL OTHER ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND/OR CIVIL REQUIREMENTS MUST BE COORDINATED BEFORE THE CONTRACTOR PROCEEDS WITH CONSTRUCTION. 7.THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION AND COORDINATION WITH ARCHITECTURAL, CIVIL, MECHANICAL, ELECTRICAL, PLUMBING, FIRE SPRINKLER DRAWINGS,AND ALL OTHER RELATED DRAWINGS. THE CONTRACTOR IS RESPONSIBLE FOR THE AND ALL OTHER RELATED DRAWINGS. 8.IN ALL CASES WHERE A CONFLICT MAY OCCUR SUCH AS BETWEEN ITEMS INCLUDED IN THE SPECIFICATIONS AND NOTES ON THE DRAWINGS, OR BETWEEN GENERAL NOTES AND SPECIFIC DETAILS, THE ENGINEER SHALL BE NOTIFIED AND HE WILL INTERPRET THE INTENT OF THE CONTRACT DOCUMENTS. 9.ALL MATERIALS SHALL BE FURNISHED AS SHOWN HEREIN UNLESS ALTERNATES ARE APPROVED IN WRITING BY THE ARCHITECT, OWNER AND STRUCTURAL ENGINEER OF RECORD. 10.ANY REFERENCE TO THE WORDS APPROVED OR APPROVAL IN THESE DOCUMENTS SHALL BE DEFINED TO MEAN GENERAL ACCEPTANCE OR REVIEW AND SHALL NOT RELIEVE THE CONTRACTOR AND/OR HIS SUBCONTRACTORS OF ANY LIABILITY IN FURNISHING THE REQUIRED MATERIALS OR LABOR SPECIFICATION. 11.WHERE A DETAIL, SECTION OR NOTE IS SHOWN FOR ONE CONDITION, IT SHALL APPLY FOR ALL LIKE OR SIMILAR CONDITIONS UNLESS NOTED OTHERWISE. DETAILS MARKED "TYPICAL" SHALL APPLY IN ALL CASES UNLESS SPECIFICALLY INDICATED OTHERWISE. WHERE NO SPECIFIC DETAIL IS SHOWN, THE FRAMING OR CONSTRUCTION SHALL BE IDENTICAL OR SIMILAR TO LIKE CASES OF CONSTRUCTION. 12.CONNECTIONS OF ALL ITEMS SUPPORTED BY THE STRUCTURE ARE THE RESPONSIBILITY OF THE DISCIPLINES WHO MAKE THESE ATTACHMENTS. REVIEW AND COORDINATE ALL THE REQUIREMENTS IN THE ARCHITECTS PROJECT SPECIFICATION AS APPLICABLE. 13.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES, WHETHER INDICATED ON THE CONTRACT DRAWING OR NOT, AND TO PROTECT THEM FROM DAMAGE. REPAIR AND REPLACEMENT OF SAID WORK SHALL BE AT THE EXPENSE OF THE CONTRACTOR. 14.VIBRATIONAL EFFECTS OF MECHANICAL AND/OR ANY OTHER EQUIPMENT HAVE NOT BEEN CONSIDERED BY THE STRUCTURAL ENGINEER. 15.UNLESS NOTED OTHERWISE, ELEVATIONS SHOWN ON THE STRUCTURAL DRAWINGS ARE TO THE TOP OF BEAMS AND FOUNDATIONS. BEAMS DENOTED AS "DROP" HAVE THE TOP OF BEAM AT THE HEIGHT OF THE TOP PLATE. BEAMS DENOTED AS "FLUSH" HAVE THE BOTTOM OF BEAM AT THE HEIGHT OF THE TOP PLATE, U.N.O. 5.LUMBER GRADES ( U.N.O. ) 6X & 8X POSTS/BEAMS/HEADERS: #1 DFL 4X POSTS/BEAMS/HEADERS: #2 DFL 2X JOISTS/RAFTERS: #2 DFL STUDS: D.F.L. STUD GRADE (UP TO 9'-0"), D.F.L. #2 (HIGHER THAN 9'-0") TOP PLATES & MUD SILLS: D.F.L. CONSTRUCTION GRADE,#2, OR BETTER. 6.TYPICAL FLOOR SHEATHING 23/32" APA RATED STURD-I-FLOOR T&G EXP I (OR OSB) WITH MIN. SPAN RATING OF 24" O.C. REFER TO NER 108 FOR INSTALLATION AND CONDITIONS OF USE B.N.:10D COMMON NAILS AT 6" O.C. E.N.:10D COMMON NAILS AT 6" O.C. F.N.:10D COMMON NAILS AT 12" O.C. USE RING OR SCREW SHANK NAILS AND GLUE SHEATHING TO FRAMING USING ADHESIVES MEETING APA SPECIFICATION AFG-01 OR ASTM D3498. APPLY GLUE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. AS AN ALTERNATE TO 10D COMMON NAILS, THE FOLLOWING FASTNERS CAN BE USED: GRABBER PLYWOOD SCREWS (ICC-ER-5280), OR SIMPSON STRONG-TIE QUICK DRIVE SCREWS (ICC-ER-1472), MIN 2" LONG @ 6" O.C. B.S., @ 6" O.C. E.S. AND 12" O.C. F.S. 7.TYPICAL ROOF SHEATHING DOC PS1 OR DOC PS2. 15/32" APA RATED SHEATHING EXP 1 (OR OSB) WITH A MIN. PANEL INDEX OF 32/16. REFER TO NER 108 FOR INSTALLATION AND CONDITIONS OF USE. B.N.:8D COMMON NAIL AT 6" O.C. E.N.:8D COMMON NAIL AT 6" O.C. F.N.:8D COMMON NAIL AT 12" O.C. NOTE*: ALL STRUCTURAL RATED PANELS MUST BE STAMPED BY ONE OF THE FOLLOWING APPROVED AGENCIES, APA, PFS/TECO OR PITTSBURG. ANCHOR BOLTS: 1.MINIMUM 5/8"Ø STEEL BOLTS EMBEDDED 7" @ 48" O.C. INTO THE FOUNDATION WITH MINIMUM 3" S.Q x 0.25" PLATE WASHER FOR THE ANCHOR BOLTS. MINIMUM EDGE DISTANCE 1-7/8" AND WITHIN 12" OF EACH END OF EACH PLATE. 2.ALL SHEAR HARDWARE AND ANCHOR BOLTS W/ NON-STANDARD SPACING ARE TO BE FIXED IN PLACE FOR THE FOUNDATION INSPECTION. 3.FASTENERS FOR PRESERVATIVE-TREATED SHALL BE NOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. 4.A PROPERLY SIZED NUT AND WASHER SHALL BE TIGHTENED ON EACH ANCHOR BOLT TO THE PLATE. 5.HOLDOWN CONNECTORS BOLTS HOLES SHALL NOT BE MORE THAN 1/16" OVERSIZED AT THE CONNECTOR OF THE HOLD DOWN TO THE POST. 6.HOLD DOWN CONNECTORS SHALL BE RE-TIGHTENED JUST PRIOR TO COVERING THE WALL FRAMING. 7.ALL FOUNDATIONS SHALL BEAR UPON LIKE MATERIAL. 8.FINAL SOILS / AS-GRADED REPORT WILL BE REQUIRED AT FOUNDATION / SLAB INSPECTION. NAILING SCHEDULE: (TABLE R602.3(1) W/ FOOT NOTES 2022 CRC) ITEM DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENERa, b, c SPACING AND LOCATION 1 Blocking between ceiling joists or rafters to top plate 4-8d box (2 1/2″ × 0.113″) or 3-8d common (2 1/2″ × 0.131″); or 3-10d box (3″ × 0.128″); or 3-3″ × 0.131″ nails Toe nail 2 Ceiling joists to top plate 4-8d box (2 1/2″ × 0.113″); or 3-8d common 2 1/2″ × 0.131″); or 3-10d box (3″ × 0.128″); or 3-3″ × 0.131″ nails Per joist, toe nail 3 Ceiling joist not attached to parallel rafter, laps over partitions [see Sections R802.3.1, R802.3.2 and Table R802.5.1(9)] 4-10d box (3″ × 0.128″); or 3-16d common (3 1/2″ × 0.162″); or 4-3″ × 0.131″ nails Face nail 4 Ceiling joist attached to parallel rafter (heel joint) [see Sections R802.3.1 and R802.3.2 and Table R802.5.1(9)] Table R802.5.1(9)Face nail 5 Collar tie to rafter, face nail or 11/4″ × 20 ga. ridge strap to rafter 4-10d box (3″ × 0.128″); or 3-10d common (3″ × 0.148″); or 4-3″ × 0.131″ nails Face nail each rafter 6 Rafter or roof truss to plate 3-16d box nails (3 1/2″ × 0.135″); or 3-10d common nails (3″ × 0.148″); or 4-10d box (3″ × 0.128″); or 4-3″ × 0.131″ nails 2 toe nails on one side and 1 toe nail on opposite side of each rafter or truss 7 Roof rafters to ridge, valley or hip rafters or roof rafter to minimum 2″ ridge beam 4-16d (3 1/2″ × 0.135″); or 3-10d common (3 1/2″ × 0.148″); or 4-10d box (3″ × 0.128″); or 4-3″ × 0.131″ nails Toe nail 3-16d box 3 1/2″ × 0.135″); or 2-16d common (3 1/2″ × 0.162″); or 3-10d box (3″ × 0.128″); or 3-3″ × 0.131″ nails End nail WALL 8 Stud to stud (not at braced wall panels) 16d common (3 1/2″ × 0.162″)24″ o.c. face nail 10d box (3″ × 0.128″); or 3″ × 0.131″ nails 16″ o.c. face nail 9 Stud to stud and abutting studs at intersecting wall corners (at braced wall panels) 4-10d box (3″ × 0.128″); or 3-16d common (3 1/2″ × 0.162″); or 4-3″ × 0.131″ nails 12″ o.c. face nail 16d common (3 1/2″ × 0.162″)16″ o.c. face nail 10 Built-up header (2″ to 2″ header with 1/2″ spacer) 16d common (3 1/2″ × 0.162″)16″ o.c. each edge face nail 16d box (3 1/2″ × 0.135″)12″ o.c. each edge face nail 11 Continuous header to stud 5-8d box (2 1/2″ × 0.113″); or 4-8d common (2 1/2″ × 0.131″); or 4-10d box (3″ × 0.128″) Toe nail 12 Top plate to top plate 16d common (3 1/2″ × 0.162″)16″ o.c. face nail 10d box (3″ × 0.128″); or 3″ × 0.131″ nails 12″ o.c. face nail 13 Double top plate splice for SDCs A-D2 with seismic braced wall line spacing < 25' 8-16d common (3 1/2″ × 0.162″); or 12-16d box (3 1/2″ × 0.135″); or 12-10d box (3″ × 0.128″); or 12-3″ × 0.131″ nails Face nail on each side of end joint (minimum 24″ lap splice length each side of end joint)Double top plate splice SDCs D0, D1, or D2; and braced wall line spacing ≥ 25' 12-16d (3 1/2″ × 0.135″) 14 Bottom plate to joist, rim joist, band joist or blocking (not at braced wall panels) 16d common (3 1/2″ × 0.162″)16″ o.c. face nail 16d box (3 1/2″ × 0.135″); or 3″ × 0.131″ nails 12″ o.c. face nail 15 Bottom plate to joist, rim joist, band joist or blocking (at braced wall panel) 3-16d box (3 1/2″ × 0.135″); or 2-16d common (3 1/2″ × 0.162″); or 4-3″ × 0.131″ nails 3 each 16″ o.c. face nail 2 each 16″ o.c. face nail 4 each 16″ o.c. face nail 16 Top or bottom plate to stud 4-8d box (2 1/2″ × 0.113″); or 3-16d box (3 1/2″ × 0.135″); or 4-8d common (2 1/2″ × 0.131″); or 4-10d box (3″ × 0.128″); or 4-3″ × 0.131″ nails Toe nail 3-16d box (3 1/2″ × 0.135″); or 2-16d common (3 1/2″ × 0.162″); or 3-10d box (3″ × 0.128″); or 3-3″ × 0.131″ nails End nail 17 Top plates, laps at corners and intersections 3-10d box (3″ × 0.128″); or 2-16d common (3 1/2″ × 0.162″); or 3-3″ × 0.131″ nails Face nail 18 1″ brace to each stud and plate 3-8d box (2 1/2″ × 0.113″); or 2-8d common (2 1/2″ × 0.131″); or 2-10d box (3″ × 0.128″); or 2 staples 1 3/4″ Face nail 19 1″ × 6″ sheathing to each bearing 3-8d box (2 1/2″ × 0.113″); or 2-8d common (2 1/2″ × 0.131″); or 2-10d box (3″ × 0.128″); or 2 staples, 1″ crown, 16 ga., 1 3/4″ long Face nail 20 1″ × 8″ and wider sheathing to each bearing 3-8d box (2 1/2″ × 0.113″); or 3-8d common (2 1/2″ × 0.131″); or 3-10d box (3″ × 0.128″); or 3 staples, 1″ crown, 16 ga., 1 3/4″ long Face nailWider than 1″ × 8″ 4-8d box (2 1/2″ × 0.113″); 3-8d common (2 1/2″ × 0.131″); or 3-10d box (3″ × 0.128″); or 4 staples, 1″ crown, 16 ga., 1 3/4″ long FLOOR 21 Joist to sill, top plate or girder 4-8d box (2 1/2″ × 0.113″); or 3-8d common (2 1/2″ × 0.131″); or 3-10d box (3″ × 0.128″); or 3-3″ × 0.131″ nails Toe nail 22 Rim joist, band joist or blocking to sill or top plate (roof applications also) 8d box (2 1/2″ × 0.113″)4″ o.c. toe nail 8d common (2 1/2″ × 0.131″); or 10d box (3″ × 0.128″); or 3″ × 0.131″ nails 6″ o.c. toe nail 23 1″ × 6″ subfloor or less to each joist 3-8d box (2 1/2″ × 0.113″); or 2-8d common (2 1/2″ × 0.131″); or 3-10d box (3″ × 0.128″); or 2 staples, 1″ crown, 16 ga., 1 3/4″ long Face nail 24 2″ subfloor to joist or girder 3-16d box (3 1/2″ × 0.135″); or 2-16d common (3 1/2″ × 0.162″)Blind and face nail 25 2″ planks (plank & beam—floor & roof) 3-16d box (3 1/2″ × 0.135″); or 2-16d common (3 1/2″ × 0.162″) At each bearing, face nail 26 Band or rim joist to joist 3-16d common (3 1/2″ × 0.162″) 4-10 box (3″ × 0.128″), or 4-3″ × 0.131″ nails; or 4-3″ × 14 ga. staples, 7/16″ crown End nail 27 Built-up girders and beams, 2-inch lumber layers 20d common (4″ × 0.192″) Nail each layer as follows: 32″ o.c. at top and bottom and staggered. 10d box (3″ × 0.128″); or 3″ × 0.131″ nails 24″ o.c. face nail at top and bottom staggered on opposite sides And: 2-20d common (4″ × 0.192″); or 3-10d box (3″ × 0.128″); or 3-3″ × 0.131″ nails Face nail at ends and at each splice 28 Ledger strip supporting joists or rafters 4-16d box (3 1/2″ × 0.135″); or 3-16d common (3 1/2″ × 0.162″); or 4-10d box (3″ × 0.128″); or 4-3″ × 0.131″ nails At each joist or rafter, face nail 29 Bridging to joist 2-10d (3″ × 0.128″)Each end, toe nail ITEM DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENER a, b, c SPACING OF FASTENERS Edges (inches)h Intermediate supports c, e (inches) Wood structural panels, subfloor, roof and interior wall sheathing to framing and particleboard wall sheathing to framing [see Table R602.3(3) for wood structural panel exterior wall sheathing to wall framing] 30 3/8″ – 1/2″ 6d common (2″ × 0.113″) nail (subfloor, wall) 8d common (21/2″ × 0.131″) nail (roof) 6 12f 31 19/32″ – 1″8d common nail (21/2″ × 0.131″)6 12f 32 11/8″ – 11/4″10d common (3″ × 0.148″) nail; or 8d (21/2″ × 0.131″) deformed nail 6 12 Other wall sheathing 33 1/2″ structural cellulosic fiberboard sheathing 1 1/2″ galvanized roofing nail, 7/16″ head diameter, or 1″ crown staple 16 ga., 1 1/4″ long 3 6 34 25/32″ structural cellulosic fiberboard sheathing 1 3/4″ galvanized roofing nail, 7/16″ head diameter, or 1″ crown staple 16 ga., 1 1/4″ long 3 6 35 1/2″ gypsum sheathingd 1 1/2″ galvanized roofing nail; staple galvanized, 1 1/2″ long; 1 1/4″ screws, Type W or S 7 7 36 5/8″ gypsum sheathingd 1 3/4″ galvanized roofing nail; staple galvanized, 1 5/8″ long; 1 5/8″ screws, Type W or S 7 7 Wood structural panels, combination subfloor underlayment to framing 37 3/4″ and less 6d deformed (2″ × 0.120″) nail; or 8d common (2 1/2″ × 0.131″) nail 6 12 38 7/8″ – 1″8d common (2 1/2″ × 0.131″) nail; or 8d deformed (2 1/2″ × 0.120″) nail 6 12 39 1 1/8″ – 1 1/4″10d common (3″ × 0.148″) nail; or 8d deformed (2 1/2″ × 0.120″) nail 6 12 1.REINFORCING STEEL SHALL BE PLACED IN ACCORDANCE WITH ACI 315 AND ACI 318, AND CRSI'S MANUAL OF STANDARD PRACTICE. 2.REINFORCING STEEL SHALL CONFORM TO ASTM A615OR ASTM 716(WELDABLE STEEL) AND SHALL BE GRADE 60 DEFORMED BARS, TYP., U.N.O. REINFORCING IN SLAB ON GRADE MAYBE GRADE 40 STEEL FOR BARS #4 AND SMALLER U.N.O ON THE PLANS. 3.WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A185. LAPS IN WWF SHALL BE SUCH THAT THE OVERLAP MEASURED BETWEEN OUTERMOST CROSS WIRE OF EACH FABRICH SEET IS NOT LESS THAN THE SPACING OF CROSS WIRES PLUS 2 INCHES. 4.ALL DIMENSIONS SHOWING THE LOCATION OF REINFORCING BARS/STEEL ARE TO THE CENTER OF STEEL U.N.O. ON THE PLANS OR DETAILS: CONDITION COVER A. CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" B. EXPOSED TO EARTH OR WEATHER (INCLUDING SLABS ON GRADE) #6 AND LARGER 2" #5 AND SMALLER 1 1/2" C. NOT EXPOSED TO WEATHER OR IN CONTACT WITH SOIL: 1. STRUCTURAL SLABS, WALLS w/ #11 BARS AND SMALLER 3/4" #14 BARS AND LARGER 1 1/2" 2. BEAMS, COLUMNS 1 1/2" 5.LAP SPLICES OF BARS SHALL CONFORM TO THE TYPICAL THE LAP SCHEDULE ON THE PLANS, U.N.O. NO TACK WELDING OF BARS ALLOWED 6.MECHANICAL SPLICE COUPLERS MAY BE USED AND SHALL HAVE CURRENT ICC APPROVAL AND BE CAPABLE OF DEVELOPING 125% OF THE BAR'S YIELD STRENGTH. 7.ALL REINFORCING BARS SHALL BE BENT COLD. DO NOT FIELD BEND OR UNBEND ANY BARS IN A MANNER THAT MAY DAMAGE REINFORCING. 8.REINFORCING SPACING SHOWN ON THE PLANS ARE THE MAXIMUM SPACING "ON CENTER SPACING". DO NOT EXCEED THIS. ANY DISCREPANCIES DURING CONSTRUCTION SHALL BE FORWARDED TO THE ENGINEER FOR REVIEW AND APPROVAL. 9.TYPICAL REINFORCING FOR CONCRETE SLAB ON METAL DECK SHALL BE 6x6-W1.4xW1.4 WELDED WIRE FABRIC, U.N.O. PLACE WWF MID-DEPTH OF THE SLAB OVER THE TOP OF THE FLUTE OF THE METAL DECK. 10.ALL DOWELS TO BE SET IN CONCRETE SHALL BE TIED IN PLACE PRIOR TO PLACEMENT OF CONCRETE. NO WET SETTING, STABBING, RODDING OR OTHER MOVEMENT OF EMBEDDED ITEMS SHALL BE PERFORMED DURING THE PLACEMENT OF CONCRETE. 11.DOWELS BETWEEN FOOTING AND WALLS OR COLUMNS SHALL BE THE SAME GRADE, SIZE AND SPACING AS THE MAIN REINFORCING, UNO. 12.CHAIRS OR SPACERS FOR REINFORCING SHALL BE NON-FERROUS OR PLASTIC COATED WHEN RESTING ON EXPOSED SURFACES. 1.CONCRETE SHALL BE SUPPLIED AND PLACED IN ACCORDANCE WITH THE LATEST EDITION OF ACI 318 AND ACI 301 EXCEPT AS MODIFIED BY THE CONSTRUCTION DOCUMENTS. 2.PORLAND CEMENT SHALL CONFORM TO ASTM C-150, TYPE II, U.N.O. 3.AGGREGATE FOR STONE CONCRETE SHALL CONFORM TO ASTM C-33. FOR LOWSHRINKAGE AGGREGATE, USE LIMESTONE OR GRANITE. AGGREGATE FORLIGHTWEIGHTCONCRETE SHALL CONFORM TO ASTM C-330 4.DO NOT USE ANY CONCRETE OR GROUT CONTAINING CHLORIDES. WATER USED IN MIXING CONCRETE SHALL CONFORM WITH ASTM C1602. 5.CONCRETE MIX DESIGNS CONTAINING FLY ASH MAY BE USED WHERE CONCRETE IS NOT VISUALLY EXPOSED. FLY ASH SHALL CONFORM WITH ASTM C618 AND MAY REPLACE UP TO 20% PORTLAND CEMENT BY VOLUME. 6.CONCRETE STRENGTH TEST REPORTS SHALL BE IN COMPLIANCE WITH ACI 318 AND SHALL BE SUBMITTED TO E.O.R. FOR REVIEW. 7.ALL REINFORCING BARS, ANCHOR BOLTS AND ALL OTHER CONCRETE INSERTS SHALL BE WELL SECURED IN POSITION PRIOR TO PLACING CONCRETE. 8.THE CONCRETE COMPRESSIVE STRENGTH (28 DAYS), f'c: a. ALL LOCATIONS, U.N.O: MIN 2500 PSI, (W/C = 0.45) SPECIAL INSPECTION IS REQUIRED WHEN f'c > 2500 PSI. b. CONCRETE IN CONTACT WITH SOIL CONTAINING SULFATE So4 ≥ 0.1% BY WEIGHT: 4000 PSI, SPECIAL INSPECTION IS NOT REQUIRED. c. CONCRETE IN CONTACT WITH SOIL CONTAINING SULFATE So4 ≥ 0.2% BY WEIGHT: 4500 PSI, SPECIAL INSPECTION IS NOT REQUIRED. 9.TIME BETWEEN CONCRETE BATCHING AND PLACEMENT SHALL BE IN ACCORDANCE WITH ASTM C94. 10.CONCRETE PLACEMENT/CURING/REDUCTION IN STRENGTH SHALL CONFORM TO ACI 305R AND 3065R REQUIREMENTS FOR HOT AND COLD WEATHER CONCRETING. 11.CONCRETE SHALL BE CURED PER ACI 308R, UNLESS ALTERNATE METHODS OF CURING HAVE BEEN APPROVED BY THE ARCHITECT OR ENGINEER. FOR SLAB CURING, CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING COMPATIBILITY OF CURING COMPOUNDS WITH PROPOSED FINISHES PRIOR TO COMMENCING ANY WORK. 12.MAX. SLUMP SHALL BE 5 INCHES EXCEPT WHERE ADMIXTURES/PLACITIZERS HAVE BEEN ADDED IN THE MIX DESIGN TO IMPROVE FLOW ABILITY/WORKABILITY. THE SLUMP LIMIT SHALL BE BASED ON ADMIXTURE MANUFACTURER'S RECOMMENDATIONS. 1.ALL STRUCTURAL LUMBER SHALL BE DOUGLAS FIR LARCH CONFORMING TO WEST COAST LUMBER INSPECTION BUREAU GRADING RULES #17. MOISTURE CONTENT NOT TO EXCEED 19% AT TIME OF CONSTRUCTION. 2.WOOD-BASED STRUCTURAL USE PANELS SHALL MEET THE REQUIREMENTS OF DOC PS 2-10. STRUCTURAL SHEATHING MAY BE EITHER OSB OR PLYWOOD. 3.STRUCTURAL COMPOSITE LUMBER (SCL) SHALL CONFORM TO THE MANUFACTURER'S ICC REPORT IN COMPLIANCE WITH THE GOVERNING BUILDING CODE FOR THE PROJECT LISTED. 4.ENGINEERED GLU-LAM BEAMS SHALL BE INSPECTED AND AN A.I.T.C. CERTIFICATE OF COMPLIANCE SHALL BE PROVIDED TO THE INSPECTOR PRIOR TO INSTALLATION. ALL GLU-LAM BEAMS SHALL BE FABRICATED WITH WATERPROOF GLUE WITH STANDARD CAMBER U.N.O. 5.GLU-LAM BEAMS MAY NOT BE SUBSTITUTED FOR STRUCTURAL COMPOSITE LUMBER (SCL) BEAMS UNLESS WRITTEN AUTHORIZATION IS PROVIDED BY THE ENGINEER OF RECORD. 6.ALL WOOD FRAMING MEMBERS DIRECTLY AGAINST CONCRETE OR MASONRY INSTALLED IN A DRY OR ENCLOSED ENVIRONMENT SHALL BE PRESSURE TREATED DOUG-FIR TREATED WITH SODIUM BORATE (SBX/DOT). CORROSION RESISTANT CONNECTORS ARE NOT REQUIRED WITH SODIUM BORATE TREATED LUMBER. IF OTHER TREATMENTS ARE USED, GALVANIZED FASTENERS PER "FASTENER REQUIREMENTS" NOTE 3 ARE REQUIRED. 7.LUMBER GRADE STAMPS ARE TO REMAIN IN PLACE AFTER INSTALLATION WHERE POSSIBLE. 8.LUMBER GRADES ARE TO BE AS FOLLOWS: STUDS UP TO 10'-0"..............................................................................................STUD GRADE STUDS OVER 10'-0".............................................................................................................DF #2 BLOCKING............................................................................................STANDARD OR BETTER PLATES & SILL.....................................................................................STANDARD OR BETTER TOP PLATES........................................................................................................................DF #2 4X4 BEAMS/POSTS.............................................................................STANDARD OR BETTER 4X6 THROUGH 4X12BEAMS/POSTS.................................................................................DF #2 4X14BEAMS/POSTS.............................................................................................................DF#1 6X & LARGER BEAMS/POSTS............................................................................................DF #1 2X RAFTER/JOIST...............................................................................................................DF #2 9.UTILITY GRADE LUMBER IS UNACCEPTABLE FOR ANY PURPOSE. 10.THE FOLLOWING BEAMS/HEADERS/RIMS CAN BE FROM ANY MANUFACTURER WITH CURRENT APPROVED ICC ES - EVALUATION REPORT WITH THE FOLLOWING MECHANICAL PROPERTIES: FOR "LVL" & "PSL" BEAMS: Fb = 2900 psi (MIN), Fv = 290 psi (MIN), E = 2.0 x 106 psi (MIN). FOR "LSL" BEAMS/HEADERS: Fb = 2325 psi (MIN), Fv = 400 psi (MIN), E = 1.55 x 106 psi (MIN). FOR MANUFACTURED RIM BOARD WITH MIN 1 1/4" THICK, CONTINUOUSLY SUPPORTED BY WALL , AND MATCHES JOIST DEPTH: Fc I (PERPENDICULAR)........ = 680 psi (MIN) Fc // (PARALLEL)..................... = 1400 psi (MIN) Ft = 1075 psi (MIN), E = 1.3 x 106 psi (MIN) GLU-LAM BEAM SHALL BE 24F-V4, DF/DF Fb = 2400 psi @ BOTTOM, Fb = 1850 psi @ TOP Fv = 265 psi (MIN), E = 1.8 x 106 psi (MIN). 11.ROOF SHEATHING SHALL BE 15/32" APA RATED SHEATHING EXP 1 WITH A SPAN RATING OF 24/0 WITH 8D NAILS AT 6" O/C AT EDGES AND BOUNDARIES AND 12" O/C FIELD NAILING. 12.FLOOR SHEATHING SHALL BE 23/32" APA RATED SHEATHING EXP 1 WITH A MINIMUM SPAN RATING OF 48/24 WITH 10D NAILS AT 6" O/C AT EDGES AND BOUNDARIES AND 10" O/C FIELD NAILING. FOUNDATION 1.THE FOUNDATION DESIGN IS BASED UPON CHAPTER 4 C.R.C. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIREMENTS THEREIN AND MAINTAIN A COPY ON THE JOB SITE AT ALL TIMES. 2.THE ENGINEER OF RECORD MUST BE INFORMED OF ANY CHANGES IN DESIGN CRITERIA MADE BY ANY SOILS GEOLOGIST IN THE COURSE OF CONSTRUCTION. 3.ALL FOOTINGS AND SLABS SHALL BE FOUNDED ON FIRM UNDISTURBED NATURAL SOILS OR APPROVED COMPACTED FILL. CONTRACTOR TO PROVIDE BUILDING INSPECTOR WITH COMPACTION REPORTS AND/OR WRITTEN APPROVAL OF COMPACTED FILL FROM A SOIL GEOLOGIST FOR ANY REQUIRED FILL. 4.ALL COMPACTED FILL SHALL BE PLACED IN AN APPROVED MANNER WITH A MINIMUM DENSITY OF 90% OF THE MAXIMUM OBTAINABLE IN ACCORDANCE WITH ASTM D 1557. 5.ALL FOUNDATION EXCAVATIONS, FILLING, BACK FILLING, AND BUILDING PADS SHALL BE INSPECTED AND APPROVED BY THE CITY BUILDING INSPECTOR BOTH PRIOR TO, AND AFTER PLACEMENT OF REINFORCEMENT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SHORING NECESSARY TO SUPPORT CUT AND/OR FILL SECTIONS DURING EXCAVATION AND FOR FORMING AND PLACEMENT OF CONCRETE. 6.THE CONTRACTOR SHALL INFORM THE ARCHITECT AND ENGINEER OF THE LOCATION OF EXISTING UTILITIES AND COMMENCE WORK ONLY AFTER WRITTEN APPROVAL FROM THE ARCHITECT. 7.ALL RETAINING WALLS HAVE BEEN DESIGNED AS A FREE DRAINING CONDITION. DESIGN FOR THE DRAINAGE SYSTEM SHALL BE BY OTHERS AND SHALL MEET THE REQUIREMENTS OF THE SOILS REPORT.BACK FILL AGAINST WALLS SHALL BE PLACED EVENLY AGAINST BOTH SIDES OF WALLS UNTIL THE LOWER GRADE IS REACHED. 8.FOOTING WITH MINIMUM REINFORCEMENT OF: 2#4 @ TOP & 2#4 @ BOTTOM. OR U.N.O 9.EXISTING FOOTING : USE EPOXY FOR A.B. WITH SAME LENGTH AS REGULAR BOLTS WITH SPECIAL INSPECTION. GENERAL 1.ALL CONCRETE MASONRY MATERIALS AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH BUILDING CODE, CHAPTER 21. MATERIALS 2.ALL MATERIALS MAKING UP FINISHED CONCRETE MASONRY CONSTRUCTION SHALL CONFORM TO STANDARDS REQUIRED BY BUILDING CODE SEC. 2103. 3.MORTAR SHALL BE TYPE M OR S AS APPLICABLE AND CONFORMING WITH ASTM C270 AND SHALL BE PROPORTIONED PER ARTICLE 2.1 & 2.6A OF SPECIFICATION FOR MASONRY STRUCTURES (TMS 602-16). 4.GROUT SHALL COMPLY WITH ARTICLE 2.2 OF TMS 602-16 AND SHALL ATTAIN A MINIMUM COMPRESSION STRENGTH AT 28 DAYS OF 1500 PSI OR THE REQUIRED COMPRESSION, F'M, WHICHEVER IS GREATER. THE COMPRESSIVE STRENGTH OF GROUT SHALL BE DETERMINED IN ACCORDANCE WITH ASTM C-1019. 5.CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90 FOR LOAD BEARING CONCRETE MASONRY UNITS. CONCRETE BRICK SHALL CONFORM TO ASTM C55, SPECIFICATIONS FOR CONCRETE BUILDING BRICK. 6.GRADE N CONCRETE BRICKS ARE FOR USE AS ARCHITECTURAL VENEER AND FACING, LIMITED TO IN EXTERIOR WALLS. 7.GRADE S CONCRETE BRICKS ARE FOR GENERAL USE WHERE MODERATE STRENGTH AND RESISTANCE TO FROST ACTION AND MOISTURE PENETRATION IS REQUIRED. STRENGTH 8.THE SPECIFIED COMPRESSIVE STRENGTH OF MASONRY, F'M, SHALL BE 2000 PSI, UNLESS NOTED OTHERWISE. IF HIGHER F'M IS NOTED, IT SHALL BE VERIFIED BY PRISM TESTS AS REQUIRED IN ARTICLE 1.4 SPECIFICATION OF MASONRY STRUCTURES (TMS 602-16). 9.REINFORCING STEEL SHALL CONFORM TO ASTM A615. GRADE 40 FOR SIZES #3 AND GRADE 60 FOR SIZES #4 AND LARGER. SPECIAL INSPECTION 10.SPECIAL INSPECTION FOR CONCRETE MASONRY CONSTRUCTION SHALL BE CARRIED OUT IN ACCORDANCE WITH BUILDING CODE SECTION 1704 AND REQUIREMENTS IN SPECIAL INSPECTION TABLES ON SHEET SN-1. MASONRY COMPRESSIVE STRENGTH, F'M SHALL BE VERIFIED BY UNIT STRENGTH METHOD OR PRISM TEST METHOD PRIOR TO AND DURING CONSTRUCTION AS DESCRIBED IN ARTICLE 1.4 SPECIFICATION FOR MASONRY STRUCTURES (TMS 602-16). DESIGN CRITERIA SHEET INDEX BASIC SEISMIC FORCE RESISTING SYSTEM: STEEL COLUMN ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE No.SHEET NO.SHEET NAME 1 S0.0 GENERAL STRUCTURAL NOTES. 2 S1.0 STRUCTURAL PLAN & DETAILS. 1.SOILS SOILS ALLOWABLE DESIGN VALUES IS 1500 PSF, 3.DESIGN LOADS: 4.LATERAL LOADS: ROOF LOAD DEAD LOAD = 13.5 PSF LIVE LOAD = 20 PSF TOTAL = 33.5 PSF RISK CATEGORY: II SEISMIC DESIGN CATEGORY: D SEISMIC IMPORTANCE FACTOR (I) = 1.0 SITE CLASS = D-Default WIND SPEED:95 MPH WIND EXPOSURE:C Ss:1.325 S1:0.472 Csy:0.30 Ry:2.5 Csx:0.30 RX: 2.5 2.BUILDING CODE - 2022 CALIFORNIA BUILDING CODE FLOOR LOAD DEAD LOAD = 10 PSF LIVE LOAD = 40 PSF TOTAL = 50 PSF 5 4 3 1 2 R E V I S I O N DATE BY 11122 BIXLER CIR., BUS: 714-928-2006 EMAIL: TUNGCIVIL2018@GMAIL.COM GARDEN GROVE, CA92840 FAX: 714-901-9535 PROFESSIONAL BUILDING DESIGNS, INC. THIS DRAWING AND DESIGN CONCEPTS ARE PROPRIETARY TO TUNG VO, M.S., P.E. THE DRAWING OR DESIGN CONCEPTS SHALL NOT BE USED OR REPRODUCED IN THE PART OR IN WHOLE WITHOUT THE WRITTEN PERMISSION BY TUNG VO, M.S., P.E. ARCHITECTURAL - STRUCTURAL MECHANICAL - ELECTRICAL - PLUMBING RESIDENTIAL - COMMERCIAL - INDUSTRIAL ON TIME - ON BUDGET - PROFESSIONAL WORK ONE STOP SOLUTION PBD SHEET NO.: DRAW BY: DUY NGUYEN PLOTE DATE: JOB NO.: 25409 C 69546 Exp: 06/30/26 TUNG THANH VO C I V I LSTATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER 10/19/2025 HE L I O T R O P E P A V I L I O N RE S I D E N T I A L P R O J E C T F O R Pr o j e c t A d d r e s s : 2 2 2 1 N . H E L I O T R O P E D R S A N T A A N A , C A 9 2 7 0 6 10/20/2025 BLDG CMNT. GE N E R A L S T R U C T U R A L NO T E S S0.0 1 HSS 4x3x3/8 (FB6) 3X3 (FB3) 3X3.5 (FB1) 2. 5 X 3 2X3 HSS4x.3 1 3INSIDE W O O D POST 3X3.5 (FB1) 3X 3 . 5 ( F B 1 ) 3X 3 . 5 ( F B 1 ) 3X 3 . 5 ( F B 1 ) 3X 3 . 5 ( F B 1 ) 4.5X5 (FB2)(FB2) 2. 5 X 3 2. 5 X 3 2. 5 X 3 2.5X3 2.5 X 3 2.5X 3 2.5X32.5X 3 2.5X3 2.5X3 2.5X 3 (FB4) 2X 3 (FB 4 ) 2X3 (FB4) 2X 3 (FB 4 ) 2X 3 (FB 4 ) (FB 4 ) 2X 3 4.5 x 5 (F B 5 ) 4.5 x 5 (F B 5 ) 4.5 X 5 (F B 5 ) 4.5 X 5 (F B 5 ) HSS4x.3 1 3 INSIDE W O O D POST HSS 4 x . 3 1 3 INS I D E W O O D PO S T HSS 4 x . 3 1 3 INS I D E W O O D PO S T HSS4x.313INSIDE WOO D POST HSS4x.313 INSIDE WOO D POST 3X3 (FB3) 3X 3 (F B 3 ) 3X 3 (F B 3 ) 3X 3 (F B 3 ) 3X 3 (F B 3 ) 4.5X5 (F B 2 ) 4.5 X 5 (F B 2 ) 4.5 X 5 (F B 2 ) 4.5 X 5 (F B 2 ) 4.5 X 5 5 S1.0 4 S1.0 TYP. 2 S1.0 TYP. 3 S1.0 TYP. HSS4x.3 1 3INSIDE W O O D POST HSS4x.3 1 3 INSIDE W O O D POST HSS 4 x . 3 1 3 INS I D E W O O D PO S T HSS 4 x . 3 1 3 INS I D E W O O D PO S T HSS4x.313INSIDE WOO D POST HSS4x.313 INSIDE WOO D POST 1 S1.0 TYP. 12" THICK MAT SLAB W/ #4 @ 12" O.C. TOP & BOTTOM 1'-0" SQ. TYP. 4X6 HIP (RB1) 4X6 HIP (RB1) 4X 6 H I P (R B 1 ) 4X 6 H I P (R B 1 ) 4X 6 H I P (R B 1 ) 4X 6 H I P (R B 1 ) 3X 3 (R B 2 ) 3X 3(R B 2 ) 3X3 (RB2) 3X3 (RB2) 3X 3 (R B 2 ) 3X 3 (R B 2 ) 3X3.5 3X3.5 3X 3 . 5 3X 3 . 5 3X 3 . 5 3X 3 . 5 6" D I A . PO S T 6 S1.0 TYP. 2X4 2X4 2X 4 2X 4 2X 4 2X 4 2X 2 2X2 2X2 2X 2 2X 2 2X 2 2X3 2X4 2X4 2X3 2X4 2X4 2X 3 2X 4 2X 4 2X 3 2X 4 2X 4 2X 3 2X 4 2X 4 2X 3 2X 4 2X 4 4X6 (RB3) 4X6 4X 6 (R B 3 ) 4X 6(R B 3 ) 4X 6 (R B 3 ) 4X 6(R B 3 ) (RB3) (R B 4 ) (RB4) (R B 4 ) (R B 4 ) (RB4) (R B 4 ) 5 4 3 1 2 R E V I S I O N DATE BY 11122 BIXLER CIR., BUS: 714-928-2006 EMAIL: TUNGCIVIL2018@GMAIL.COM GARDEN GROVE, CA92840 FAX: 714-901-9535 PROFESSIONAL BUILDING DESIGNS, INC. THIS DRAWING AND DESIGN CONCEPTS ARE PROPRIETARY TO TUNG VO, M.S., P.E. THE DRAWING OR DESIGN CONCEPTS SHALL NOT BE USED OR REPRODUCED IN THE PART OR IN WHOLE WITHOUT THE WRITTEN PERMISSION BY TUNG VO, M.S., P.E. ARCHITECTURAL - STRUCTURAL MECHANICAL - ELECTRICAL - PLUMBING RESIDENTIAL - COMMERCIAL - INDUSTRIAL ON TIME - ON BUDGET - PROFESSIONAL WORK ONE STOP SOLUTION PBD SHEET NO.: DRAW BY: DUY NGUYEN PLOTE DATE: JOB NO.: 25409 C 69546 Exp: 06/30/26 TUNG THANH VO C I V I LSTATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER 10/19/2025 HE L I O T R O P E P A V I L I O N RE S I D E N T I A L P R O J E C T F O R Pr o j e c t A d d r e s s : 2 2 2 1 N . H E L I O T R O P E D R S A N T A A N A , C A 9 2 7 0 6 10/20/2025 BLDG CMNT. ℄ STEEL COLUMN PER PLAN 1 1/2" DRY PACK, f'c=6,000 psi (MIN.) (4) 3/4 Ø X 9" LENGTH ANCHOR BOLTS W/ LEVELING NUT. MIN. 12"SQ.X3 4 THK. STEEL BASE PLATE TO MEET REQ. AS SHOWN. (U.N.O.) MI N . 1 2 " MIN. 12" THICK MAT CONCRETE SLAB W/ #4 @ 12" O.C. AT TOP & BOTT. 12" SQ. CONCRETE PEDESTAL W/ (8) #4 VERT. BARS EMBED INTO FOOTING W/ STD HOOKS. PROVIDE #4 TIES @ 8" O.C. MIN. SECTION VIEW STEEL COLUMN & FOOTING DETAIL PLAN VIEW 1 1/2" MIN. 1 1/2" MIN. 1 1 / 2 " MI N . 1 1 / 2 " MI N . DIA. PER PLAN BASE PLATE PIPE 1/4 3" 1' - 0 " 1'-0" MIN. 12" THICK MAT CONCRETE SLAB W/ #4 @ 12" O.C. AT TOP & BOTT. 1 FO U N D A T I O N P L A N , F R A M I N G P L A N & D E T A I L S S1.0 FOUNDATION PLAN SCALE : 3/8" = 1'-0" FLOOR FRAMING PLAN SCALE : 3/8" = 1'-0" ROOF FRAMING PLAN SCALE : 3/8" = 1'-0" HI. ROOF FRAMING PLAN SCALE : 3/8" = 1'-0" CONNECTION DETAIL HSS STEEL BEAM PER PLANHSS COLUMN PER PLAN 1/4 1/4 FRONT VIEW TOP VIEW HSS STEEL BEAM PER PLAN HSS COLUMN PER PLAN NOTE: NOTCH HSS BEAM AS REQUIRED TO FIT WITH COLUMN CONNECTION. CANT. WOOD BEAM PER PLANHSS COLUMN PER PLAN 1/4 PIPE 1 1/2 STD WELDED TO STEEL COLUMN 6" MIN. CONNECTION DETAIL ℄ WOOD BEAM PER PLANHSS BEAM PER PLAN 1/4 PIPE 3/4 STD WELDED TO STEEL COLUMN 6" MIN. CONNECTION DETAIL ℄ CONNECTION DETAIL WOOD BEAM PER PLAN WOOD POST PER PLAN FRONT VIEW TOP VIEW SIMPSON HUC PER PLAN WOOD POST PER PLAN GRIND OR CUT FLAT SURFACE ON ROUND COLUMN TO SEAT HUC HANGER. 4X6 WOOD BEAM PER PLAN SIMPSON HUC46 PER PLAN 2X4 BEAM PER PLAN SIMPSON HUC46 PER PLAN SIMPSON APLH24 2X4 BEAM PER PLAN SIMPSON APLH24 CONNECTION DETAIL HSS STEEL BEAM PER PLAN WOOD BEAM PER PLAN SIMPSON CBH2.37X5.5 WELEDED TO BEAM 12° 3/4" THICK STEEL PLATE AS SHOWN WELDED TO BEAM1/4 2534 1 6 1 1 EMAIL: tungcivil2018@gmail.com Date: 10/19/2025 TUNG THANH VO, M.S., P.E. 11122 BIXLER CIR GARDEN GROVE CA 92840 BUS: 714-928-2006 FAX: 714-901-9535 RESPONSE TO PLAN CHECK#1 ********************** CLIENT : DR. CHAN KIEU & DR. QUYNH KIEU. PROJECT NAME : HELIOTROPE PAVILION. LOCATION : 2221 N. HELIOTROPE DR SANTA ANA, CA 92706. JOB NUMBER : 25409. Structural requirements: 5. Please see updated sheet S0.0 for revised the lateral load to match with structural calculation. 6. a. Please see revised detail 1/S1.0 for callout slab thickness and reinforcement. Please see revised detail 2/A101 for coordinate to match with detail 1/S1.0 b. Please see revised roof framing plan for provide post size and connection detail 6/S1.0 per city comment. c. Please see revised framing plan for updated size of RB4 to match with the structural calculation at page 11 DESIGNED BY: TUNG VO, M.S., P.E. 2nd SUBMITAL: October 19, 2025 VERTICAL, LATERAL DESIGNED BY: TUNG VO, M.S., P.E. TUNG THANH VO, M.S., P.E. 11122 BIXLER CIR GARDEN GROVE CA 92840 BUS: 714-928-2006 FAX: 714-901-9535 EMAIL: tungcivil2018@gmail.com STRUCTURAL ANALYSIS ********************** SUBMITAL FOR BUILDING DEPARTMENT CLIENT : DR. CHAN KIEU & DR. QUYNH KIEU. PROJECT NAME : HELIOTROPE PAVILION. LOCATION : 2221 N. HELIOTROPE DR SANTA ANA, CA 92706. JOB NUMBER : 25409. Page 1 DESIGN CRITERIA SHEET Job# 25409 CODE: 2022 CALIFORNIA BUILDING CODE In all cases calculations will supersede this design criteria sheet. TIMBER Douglas fir-larch-19% max. moisture content. 4X Members: No .2 or Better 6X,8X Beams and Headers: No.1 or Better 2X Joists and Rafters: No. 2 or Better Plates and Blocking: Standard Grade or Better Studs: Stud Grade or Better Mud Sills: Pressure Treated Utility Grade or Better CONCRETE 1.Drypack shall be composed of one part Portland cement to not more than three-part sand. 2.All structural concrete…………………………. f’c=2500 psi w/inspection. All slab-on –grate/continuous footing /pads……… f’c=2500 psi w/inspection. All concrete shall reach minimum compressive strength at 28 days. REINFORCING STEEL 1. All reinforcing shall be A.S.T.M.A-615-40 for #4 bars and smaller, A-615-60 for #5 bars and larger. Welded wire fabric to be A.S.T.M. A-185, lab 1-1/2 spaces ,9” min. 2. Development length of Tension Bars shall be calculated per ACI318-19 Section 12.2.2. Class B splice =1.3xld. Splice lengths for 2500 psi concrete is: # 4 Bars (40k) =21”, #5 Bars (60k) =39”, #6 Bars (60k) =47” (30 dia. for compression). Masonry reinforcement shall have lappings of 48dia.or 2’-0”. This is in all cases U.N.O. 3. All reinforcing bars shall be accurately and securely placed before pouring concrete, or grouting masonry. 4. Concrete protection for reinforcement shall be at least equal to the diameter of the bars. Cover for cast-in-place concrete shall be as follows, U.N.O: A. Concrete cast against & permanently exposed to earth…………………3” B. Concrete exposed to earth or weather <= #5 Bar ………………………1 ½” #6#18 bars 2” C. Concrete not exposed to weather or in contact with ground Slab, wall, joist, <= #11bars …………………………………………… 3/4” Beams & Columns: Primary reinforcement, ties, stirrups, spirals………….1 ½” STRUCTURAL STEEL 1. Fabrication and erection of structural steel shall be in accordance with “specification for the Design, Fabrication and Erection of Structural Steel Buildings “, AISC, current edition. Steel to conform to ASTM A992.Round pipe columns shall conform to ASTM A35, Grade B.Square /Rectangular Steel tubes ASTM A500,Grade B . 2. All welding shall be performed by certified welders, using the Electric Shielded Arc Process at licensed shops or otherwise approved by the Bldg. Dept. Continuous inspection required for all field welding. 3. All steel exposed to weather shall be hot –dip galvanized after fabrication, or other approved weatherproofing method 4. Where finish is attached to structure steel, provide ½” f both holes @ 4’-0” O.C. for attachment of nailers, U.N.O. see architectural drawings for finishes (nelson studs ½”x3” CPL may replace bolts). MASONY 1. Concrete block shall be of size shown on architectural drawing and/or called for in specifications and conform to ASTM C-90-09, grade A normal weight units with max. linear shrinkage of 0.06% 2. All vertical reinforcing in masonry walls not retaining earth shall be located in the center of the wall (U.N.O.), retaining walls are to be as shown in details. 3. All cells with steel are to be solid grouted (except retaining walls where all cells are to be solid grouted). Page 2 LOADING & LATERAL ANALYSIS (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code) Job Number : 25409 Plan : GENERAL INPUT : Code :2022 CBC Wind Speed:95 mph Risk Category :II Wind Exposure:C Importance Factor, I (Seis.)1.00 Mean Roof Height :19 ft Soil Site Class :D Building Width, B :12 ft Seismic Category :D Building Lenght, L :12 ft Spectral Accel., Ss :1.325 Typ. Roof Slope:4/12 Spectral Accel., S1 :0.472 Risk Category II Structure Height, hn :19 ft Topographic Factor Kzt 1.00 Seismic Resist. System (R) :2.5 Direction Factor Kd :0.85 Soil Bearing Pressure:1500 psf Gust Effect Factor G :0.85 Concrete Strength:2500 psi Gcpi(+/-)0.18 Foundation Type : Conventional Load Combination Factor (W) :1.00 ANALYSIS SEISMIC DESIGN :(Using Equivalent Force Procedure per ASCE 7-16) Site Coefficients : Fa ==1.20 (ASCE 7-16 Table 11.4-1) Fv ==1.80 (ASCE 7-16 Table 11.4-2) Maximum Spectral Response Accelerations : SMS=Fa*Ss =1.59 (USGS Seismic Design Geodatabase) SM1=Fv*S1 =0.85 (USGS Seismic Design Geodatabase) Design Spectral Accelerations : SDS=SMS*2/3 =1.060 SD1=SM1*2/3 =0.57 Determine Building Period : Ta=Ct*(hn^x)=0.182 sec. (Approximate Fundemental Period using Eq. 12.8-7) TL =8.000 sec. (Long-period transition period per ASCE 7-16 Maps 22-15/20) Ct =0.020 x =0.750 Seismic Response Coefficients : Cs=0.7*SDS*I/(R)=0.30 (ASCE 7-16 Section 12.8-2)CONTROL Cs-max 1.245 (Eq. 12.8-3 & 12.8-4) Cs-min 0.010 (Eq. 12.8-5 & 12.8-6) ANALYSIS WIND DESIGN :(MWFRS Directional Procedure Chapter 27 Part1 per ASCE 7-16 for Building of any Height- See detail on pages Lateral Analytical Section ) LOADDING CONDITIONS : ROOF LOADING :FLOOR LOADING : Slope : Roof Material : 6.50 Floor Material : 2.50 Sheathing : 1.50 Sheathing : 1.50 Roof Rafters : 1.50 Floor Joist : 1.50 Ceiling Joist : 1.50 Carpet : 1.00 Drywall : 1.50 Drywall : 2.50 Miscellaneous : 1.00 Miscellaneous : 1.00 Total Dead Load(D.L) : 13.50 psf Total Dead Load(D.L) : 10.00 psf Live Load (L.L) : 20.00 psf Live Load (L.L) : 40.00 psf Snow Load : WALL LOADING :CEILING LOADING : Exterier Wall :(DL )15.00 psf Dead Load :6.00 psf Interier Wall :10.00 psf Live Load :10.00 psf Page 3 BEAM DESIGN Job Number 25409 Plan :1 Code : AF&PA NDS-2018 Design Method:ASD Load Combination: 2021 IBC/2022 CBC & ASCE 7-16 All timber shall be Douglas Fir-Larch-19% max .moisture content. Timber Properties : Sawn Lumber(DFL) 2X Josit& Rafters(No.2) 4X Swan Beams(No.2) 6X Swan Beams(No.1) Glued Laminated Beam Glulam 24F-V4 DF/DF Glued Laminated Beam TimberStrand LSL 1.55E Parallam PSL 2.0E Microllam LVL 1.9E Wood Post Axial Loads Capacity: POST HEIGHT (FT) Post 7 8 9 10 12 14 18.67 22 2x4 DFL STANDARD 3.29 2.64 2.14 1.76 1.25 0.93 --- --- 2x4 DFL STUD 2.89 2.42 2.01 1.69 1.22 0.91 ------ 4x4 DFL No.2 8.73 7.00 5.69 4.69 3.33 2.48 --- --- 2x6 DFL STUD 5.16 5.16 5.16 4.93 4.00 3.18 1.94 1.43 2x6 DFL No.2 5.16 5.16 5.16 5.16 5.06 3.88 2.28 1.67 4x6 DFL No.2 13.58 10.93 8.90 7.35 5.22 3.89 --- --- 4x8 DFL No.2 17.71 14.30 11.67 9.66 6.87 5.12 --- --- 4x10 DFL No.2 22.32 18.10 14.81 12.27 8.74 6.52 ------ 4x12 DFL No.2 27.15 22.01 18.01 14.92 10.63 7.93 --- --- 6x6 DFL No.1 26.37 24.84 23.01 20.99 16.90 13.42 8.15 6.00 6x8 DFL No 1 35.96 33.87 31.38 28.62 23.05 18.30 11.11 8.19 8x8 DFL No.1 52.82 51.56 50.01 48.16 43.51 37.99 25.86 19.67 Fb Fv E 900 900 180 1.6 E 180 1.6 E 1350 170 1.6 E 265 1.8 E2400/1850 2.0 E 1.9 E 1.55 E2350 2900 2600 310 285 285 Page 4 PASS DATE: 7/9/2025 COMPANY: PBD Inc STRUCALC BUILD: StruCalc Pro DESIGNED BY: Bach Nguyen CUSTOMER: REVIEWED BY: Tung Vo PROJ. ADDRESS: -- PROJECT NAME: Moon-Pavilion (1) -- LEVEL: Roof LOADING: ASD MEMBER NAME: RB1 CODE: 2021 International Building Code MEMBER TYPE: ROOF BEAM NDS: 2018 NDS MATERIAL: Solid Sawn Douglas Fir-Larch No. 2 (1) 3.5 X 5.5 DRY RB1 DIAGRAM BEAM PROPERTIES Start (ft): 0 End (ft): 3.75 Member Slope (in): 0/12 Actual Length (ft): 3.75 Area Ix Iy BSW Lams G Kcr (in²) (in⁴) (in⁴) (lbf/ft) Creep Factor 19.25 48.53 19.65 4.39 1 0.5 1 STRENGTH PROPERTIES Fb (psi) Ft (psi) Fv (psi) Fc (psi) Fc⊥(psi) E (psi) x10³ Emin (psi) x10³ Base Values 900 575 180 1350 625 1600 580 Adjusted Values 1170 748 180 1485 625 1600 580 C M 1 1 1 1 1 1 1 C T 1 1 1 1 1 1 1 C i 1 1 1 1 1 1 1 C F 1.3 1.3 1 1.1 1 1 1 Bending Adjustment Factors C fu = 1 C r = 1 BEAM DATA Unbraced Length (ft) Beam End Span Length (ft) Top Bottom Elev. Diff (ft) CL(Top) CL(Bottom) CL(Left) CL(Right) 1 3.75 0 3.75 0 PASS-FAIL Shear Stress Y (psi) Bending Stress Y (psi) Deflection Y (in) Bearing Stress (psi) PASS/FAIL PASS (88.6%) PASS (71.1%) PASS (90.3%) PASS (95.0%) MAGNITUDE 25.8 421.5 0.049 31.5 STRENGTH 225.0 1457.1 0.500 (=L/180) 625.0 LOCATION (ft) 0 0 3.75 0 LOAD COMBO D+Lr D+Lr D+Lr D+Lr DURATION FACTOR CD 1.25 1.25 1.25 Page 1 2021 International Building Code ASDPROJECT: Moon-Pavilion (1) Page 5 REACTIONS Units for V: lbf Units for M: lbf-ft DEAD LIVE ROOF TOTALY axis A 143 188 331 B 0 0 0 M@x A 268 352 620 B 0 0 0 Reaction Location A BLOAD LIST Type Name Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Uniform (lbf/ft) w_D 33.75 33.75 0 3.75 Dead Y Uniform (lbf/ft) w_LR 50 50 0 3.75 RoofLive Y Self Weight (lbf/ft)-4.39 4.39 0 3.75 Dead Y Page 2 2021 International Building Code ASDPROJECT: Moon-Pavilion (1) Member Name: RB1 Page 6 PASS DATE: 7/9/2025 COMPANY: PBD Inc STRUCALC BUILD: StruCalc Pro DESIGNED BY: Bach Nguyen CUSTOMER: REVIEWED BY: Tung Vo PROJ. ADDRESS: -- PROJECT NAME: Moon-Pavilion (1) -- LEVEL: Roof LOADING: ASD MEMBER NAME: RB2 CODE: 2021 International Building Code MEMBER TYPE: ROOF BEAM NDS: 2018 NDS MATERIAL: Solid Sawn Douglas Fir-Larch No. 2 (1) 3 X 3 DRY RB2 DIAGRAM BEAM PROPERTIES Start (ft): 0 End (ft): 5.25 Member Slope (in): 0/12 Actual Length (ft): 5.25 Area Ix Iy BSW Lams G Kcr (in²) (in⁴) (in⁴) (lbf/ft) Creep Factor 9 6.75 6.75 2.05 1 0.5 1 STRENGTH PROPERTIES Fb (psi) Ft (psi) Fv (psi) Fc (psi) Fc⊥(psi) E (psi) x10³ Emin (psi) x10³ Base Values 900 575 180 1350 625 1600 580 Adjusted Values 1350 862 180 1552 625 1600 580 C M 1 1 1 1 1 1 1 C T 1 1 1 1 1 1 1 C i 1 1 1 1 1 1 1 C F 1.5 1.5 1 1.15 1 1 1 Bending Adjustment Factors C fu = 1 C r = 1 BEAM DATA Unbraced Length (ft) Beam End Span Length (ft) Top Bottom Elev. Diff (ft) CL(Top) CL(Bottom) CL(Left) CL(Right) 1 5.25 0 5.25 0 PASS-FAIL Shear Stress Y (psi) Bending Stress Y (psi) Deflection Y (in) Bearing Stress (psi) PASS/FAIL PASS (86.6%) PASS (62.4%) PASS (68.8%) PASS (96.8%) MAGNITUDE 30.2 634.4 0.109 20.1 STRENGTH 225.0 1687.5 0.350 (=L/180) 625.0 LOCATION (ft) 5.25 2.625 2.625 0 LOAD COMBO D+Lr D+Lr D+Lr D+Lr DURATION FACTOR CD 1.25 1.25 1.25 REACTIONS Units for V: lbf Units for M: lbf-ft DEAD LIVE ROOF TOTALY axis A 76 105 181 B 76 105 181 Reaction Location A B Page 3 2021 International Building Code ASDPROJECT: Moon-Pavilion (1) Page 7 LOAD LIST Type Name Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Uniform (lbf/ft) w_D 27 27 0 5.25 Dead Y Uniform (lbf/ft) w_Lr 40 40 0 5.25 RoofLive Y Self Weight (lbf/ft)-2.05 2.05 0 5.25 Dead Y Page 4 2021 International Building Code ASDPROJECT: Moon-Pavilion (1) Member Name: RB2 Page 8 PASS DATE: 7/9/2025 COMPANY: PBD Inc STRUCALC BUILD: StruCalc Pro DESIGNED BY: Bach Nguyen CUSTOMER: REVIEWED BY: Tung Vo PROJ. ADDRESS: -- PROJECT NAME: Moon-Pavilion (1) -- LEVEL: Roof LOADING: ASD MEMBER NAME: RB3 CODE: 2021 International Building Code MEMBER TYPE: ROOF BEAM NDS: 2018 NDS MATERIAL: Solid Sawn Douglas Fir-Larch No. 2 (1) 3.5 X 5.5 DRY RB3 DIAGRAM BEAM PROPERTIES Start (ft): 0 End (ft): 5.75 Member Slope (in): 0/12 Actual Length (ft): 5.75 Area Ix Iy BSW Lams G Kcr (in²) (in⁴) (in⁴) (lbf/ft) Creep Factor 19.25 48.53 19.65 4.39 1 0.5 1 STRENGTH PROPERTIES Fb (psi) Ft (psi) Fv (psi) Fc (psi) Fc⊥(psi) E (psi) x10³ Emin (psi) x10³ Base Values 900 575 180 1350 625 1600 580 Adjusted Values 1170 748 180 1485 625 1600 580 C M 1 1 1 1 1 1 1 C T 1 1 1 1 1 1 1 C i 1 1 1 1 1 1 1 C F 1.3 1.3 1 1.1 1 1 1 Bending Adjustment Factors C fu = 1 C r = 1 BEAM DATA Unbraced Length (ft) Beam End Span Length (ft) Top Bottom Elev. Diff (ft) CL(Top) CL(Bottom) CL(Left) CL(Right) 1 5.75 0 5.75 0 PASS-FAIL Shear Stress Y (psi) Bending Stress Y (psi) Deflection Y (in) Bearing Stress (psi) PASS/FAIL PASS (86.8%) PASS (80.2%) PASS (91.7%) PASS (94.2%) MAGNITUDE 29.8 289.9 0.032 36.4 STRENGTH 225.0 1462.5 0.383 (=L/180) 625.0 LOCATION (ft) 0 2.473 2.76 0 LOAD COMBO D+Lr D+Lr D+Lr D+Lr DURATION FACTOR CD 1.25 1.25 1.25 REACTIONS Units for V: lbf Units for M: lbf-ft DEAD LIVE ROOF TOTALY axis A 161 220 381 B 87 110 197 Reaction Location A B Page 5 2021 International Building Code ASDPROJECT: Moon-Pavilion (1) Page 9 LOAD LIST Type Name Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Trapezoidal (lbf/ft) w_Lr 115 0 0 5.75 RoofLive Y Trapezoidal (lbf/ft) w_D 77.625 0 0 5.75 Dead Y Self Weight (lbf/ft)-4.39 4.39 0 5.75 Dead Y Page 6 2021 International Building Code ASDPROJECT: Moon-Pavilion (1) Member Name: RB3 Page 10 VERSIONSSIONAL USE DATE: 7/9/2025 COMPANY: PBD IncSTRUCALC BUILD: DESIGNED BY: Bach NguyenCUSTOMER:REVIEWED BY: Tung VoPROJ. ADDRESS: --PROJECT NAME: Moon Pavilion--LEVEL: Roof LOADING: ASDMEMBER NAME: RB4 CODE: 2021 International Building CodeMEMBER TYPE: ROOF BEAM NDS: 2018 NDSMATERIAL: Solid Sawn Douglas Fir-Larch No. 2 (1) 2 X 4 DRY RB4 DIAGRAM BEAM PROPERTIES Start (ft): 0 End (ft): 5.75 Member Slope (in): 0/12 Actual Length (ft): 5.75 Area Ix Iy BSW Lams G Kcr (in²)(in⁴)(in⁴)(lbf/ft)Creep Factor 8 10.67 2.67 1.82 1 0.5 1 STRENGTH PROPERTIES Fb (psi)Ft (psi)Fv (psi)Fc (psi)Fc⊥(psi)E (psi) x10³ Emin (psi) x10³ Base Values 900 575 180 1350 625 1600 580 Adjusted Values 1260 805 180 1485 625 1600 580 C M 1 1 1 1 1 1 1 C T 1 1 1 1 1 1 1 C i 1 1 1 1 1 1 1 C F 1.4 1.4 1 1.1 1 1 1 Bending Adjustment Factors C fu = 1 C r = 1 BEAM DATA Unbraced Length (ft) Beam End Span Length (ft) Top Bottom Elev. Diff (ft) CL(Top) CL(Bottom) CL(Left) CL(Right) 1 5.75 0 5.75 0 1.00 0.98 1.00 1.00 PASS-FAIL Shear Stress Y (psi) Bending Stress Y (psi) Deflection Y (in) Bearing Stress (psi) PASS/FAIL PASS (68.8%) PASS (40.6%) PASS (63.0%) PASS (90.0%) MAGNITUDE 70.2 935.7 0.142 62.4 STRENGTH 225.0 1575.0 0.383 (=L/180) 625.0 LOCATION (ft) 0 2.415 2.76 0 LOAD COMBO D+Lr D+Lr D+Lr D+Lr DURATION FACTOR CD 1.25 1.25 1.25 REACTIONS Units for V: lbf Units for M: lbf-ft DEAD LIVE ROOF TOTALY axis A 154 220 374 B 80 110 190 Reaction Location A B Page 1 2021 International Building Code ASDPROJECT: Moon Pavilion PASS Page 11 LOAD LIST Type Name Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Trapezoidal (lbf/ft) w_Lr 115 0 0 5.75 RoofLive Y Trapezoidal (lbf/ft) w_D 77.625 0 0 5.75 Dead Y Self Weight (lbf/ft)-1.82 1.82 0 5.75 Dead Y Page 2 2021 International Building Code ASDPROJECT: Moon Pavilion Member Name: RB4 Page 12 PASS DATE: 7/9/2025 COMPANY: PBD Inc STRUCALC BUILD: StruCalc Pro DESIGNED BY: Bach Nguyen CUSTOMER: REVIEWED BY: Tung Vo PROJ. ADDRESS: -- PROJECT NAME: Moon-Pavilion (1) -- LEVEL: Main Floor LOADING: ASD MEMBER NAME: FB1 CODE: 2021 International Building Code MEMBER TYPE: FLOOR BEAM NDS: 2018 NDS MATERIAL: Solid Sawn Douglas Fir-Larch No. 2 (1) 3 X 3.5 DRY FB1 DIAGRAM BEAM PROPERTIES Start (ft): 0 End (ft): 6.5 Member Slope (in): 0/12 Actual Length (ft): 6.5 Area Ix Iy BSW Lams G Kcr (in²) (in⁴) (in⁴) (lbf/ft) Creep Factor 10.5 10.72 7.88 2.39 1 0.5 1 STRENGTH PROPERTIES Fb (psi) Ft (psi) Fv (psi) Fc (psi) Fc⊥(psi) E (psi) x10³ Emin (psi) x10³ Base Values 900 575 180 1350 625 1600 580 Adjusted Values 1350 862 180 1552 625 1600 580 C M 1 1 1 1 1 1 1 C T 1 1 1 1 1 1 1 C i 1 1 1 1 1 1 1 C F 1.5 1.5 1 1.15 1 1 1 Bending Adjustment Factors C fu = 1 C r = 1 BEAM DATA Unbraced Length (ft) Beam End Span Length (ft) Top Bottom Elev. Diff (ft) CL(Top) CL(Bottom) CL(Left) CL(Right) 1 6.5 0 6.5 0 PASS-FAIL Shear Stress Y (psi) Bending Stress Y (psi) Deflection Y (in) Bearing Stress (psi) PASS/FAIL PASS (92.9%) PASS (78.9%) PASS (80.2%) PASS (98.4%) MAGNITUDE 12.8 284.7 0.064 9.9 STRENGTH 180.0 1350.0 0.325 (=L/240) 625.0 LOCATION (ft) 0 3.25 3.25 0 LOAD COMBO D+L D+L D+L D+L DURATION FACTOR CD 1 1 1 REACTIONS Units for V: lbf Units for M: lbf-ft DEAD LIVE TOTALY axis A 41 49 90 B 41 49 90 Reaction Location A B Page 9 2021 International Building Code ASDPROJECT: Moon-Pavilion (1) Page 13 LOAD LIST Type Name Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Uniform (lbf/ft) w_D 10.125 10.125 0 6.5 Dead Y Uniform (lbf/ft) Uniform 15 15 0 6.5 Live Y Self Weight (lbf/ft)-2.39 2.39 0 6.5 Dead Y Page 10 2021 International Building Code ASDPROJECT: Moon-Pavilion (1) Member Name: FB1 Page 14 PASS DATE: 7/9/2025 COMPANY: PBD Inc STRUCALC BUILD: StruCalc Pro DESIGNED BY: Bach Nguyen CUSTOMER: REVIEWED BY: Tung Vo PROJ. ADDRESS: -- PROJECT NAME: Moon-Pavilion (1) -- LEVEL: Main Floor LOADING: ASD MEMBER NAME: FB2 CODE: 2021 International Building Code MEMBER TYPE: FLOOR BEAM NDS: 2018 NDS MATERIAL: Solid Sawn Douglas Fir-Larch No. 2 (1) 4 X 5.5 DRY FB2 DIAGRAM BEAM PROPERTIES Start (ft): 0 End (ft): 0.75 Member Slope (in): 0/12 Actual Length (ft): 0.75 Area Ix Iy BSW Lams G Kcr (in²) (in⁴) (in⁴) (lbf/ft) Creep Factor 22 55.46 29.33 5.02 1 0.5 1 STRENGTH PROPERTIES Fb (psi) Ft (psi) Fv (psi) Fc (psi) Fc⊥(psi) E (psi) x10³ Emin (psi) x10³ Base Values 900 575 180 1350 625 1600 580 Adjusted Values 900 575 180 1350 625 1600 580 C M 1 1 1 1 1 1 1 C T 1 1 1 1 1 1 1 C i 1 1 1 1 1 1 1 C F 1 1 1 1 1 1 1 Bending Adjustment Factors C fu = 1 C r = 1 BEAM DATA Unbraced Length (ft) Beam End Span Length (ft) Top Bottom Elev. Diff (ft) CL(Top) CL(Bottom) CL(Left) CL(Right) 1 0.75 0 0.75 0 PASS-FAIL Shear Stress Y (psi) Bending Stress Y (psi) Deflection Y (in) Bearing Stress (psi) PASS/FAIL PASS (96.5%) PASS (95.5%) PASS (99.7%) PASS (98.8%) MAGNITUDE 6.4 40.8 0.000 7.8 STRENGTH 180.0 899.6 0.075 (=L/240) 625.0 LOCATION (ft) 0 0 0.75 0 LOAD COMBO D+L D+L D+L D+L DURATION FACTOR CD 1 1 1 Page 11 2021 International Building Code ASDPROJECT: Moon-Pavilion (1) Page 15 REACTIONS Units for V: lbf Units for M: lbf-ft DEAD LIVE TOTALY axis A 44 49 93 B 0 0 0 M@x A 32 37 69 B 0 0 0 Reaction Location A BLOAD LIST Type Name Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Self Weight (lbf/ft)-5.02 5.02 0 0.75 Dead Y Linked Load List Type Member Support Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Point (lbf) FB1 A 40.68915 -0.75 -Dead Y Point (lbf) FB1 A 48.75 -0.75 -Live Y Page 12 2021 International Building Code ASDPROJECT: Moon-Pavilion (1) Member Name: FB2 Page 16 PASS DATE: 7/9/2025 COMPANY: PBD Inc STRUCALC BUILD: StruCalc Pro DESIGNED BY: Bach Nguyen CUSTOMER: REVIEWED BY: Tung Vo PROJ. ADDRESS: -- PROJECT NAME: Moon-Pavilion (1) -- LEVEL: Main Floor LOADING: ASD MEMBER NAME: FB3 CODE: 2021 International Building Code MEMBER TYPE: FLOOR BEAM NDS: 2018 NDS MATERIAL: Solid Sawn Douglas Fir-Larch No. 2 (1) 3 X 3 DRY FB3 DIAGRAM BEAM PROPERTIES Start (ft): 0 End (ft): 5.25 Member Slope (in): 0/12 Actual Length (ft): 5.25 Area Ix Iy BSW Lams G Kcr (in²) (in⁴) (in⁴) (lbf/ft) Creep Factor 9 6.75 6.75 2.05 1 0.5 1 STRENGTH PROPERTIES Fb (psi) Ft (psi) Fv (psi) Fc (psi) Fc⊥(psi) E (psi) x10³ Emin (psi) x10³ Base Values 900 575 180 1350 625 1600 580 Adjusted Values 1350 862 180 1552 625 1600 580 C M 1 1 1 1 1 1 1 C T 1 1 1 1 1 1 1 C i 1 1 1 1 1 1 1 C F 1.5 1.5 1 1.15 1 1 1 Bending Adjustment Factors C fu = 1 C r = 1 BEAM DATA Unbraced Length (ft) Beam End Span Length (ft) Top Bottom Elev. Diff (ft) CL(Top) CL(Bottom) CL(Left) CL(Right) 1 5.25 0 5.25 0 PASS-FAIL Shear Stress Y (psi) Bending Stress Y (psi) Deflection Y (in) Bearing Stress (psi) PASS/FAIL PASS (75.2%) PASS (30.5%) PASS (27.6%) PASS (95.2%) MAGNITUDE 44.6 937.6 0.127 29.8 STRENGTH 180.0 1350.0 0.175 (=L/360) 625.0 LOCATION (ft) 5.25 2.625 2.625 0 LOAD COMBO D+L D+L L D+L DURATION FACTOR CD 1 1 1 REACTIONS Units for V: lbf Units for M: lbf-ft DEAD LIVE TOTALY axis A 58 210 268 B 58 210 268 Reaction Location A B Page 13 2021 International Building Code ASDPROJECT: Moon-Pavilion (1) Page 17 LOAD LIST Type Name Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Uniform (lbf/ft) w_D 20 20 0 5.25 Dead Y Uniform (lbf/ft) Uniform 80 80 0 5.25 Live Y Self Weight (lbf/ft)-2.05 2.05 0 5.25 Dead Y Page 14 2021 International Building Code ASDPROJECT: Moon-Pavilion (1) Member Name: FB3 Page 18 PASS DATE: 7/9/2025 COMPANY: PBD Inc STRUCALC BUILD: StruCalc Pro DESIGNED BY: Bach Nguyen CUSTOMER: REVIEWED BY: Tung Vo PROJ. ADDRESS: -- PROJECT NAME: Moon-Pavilion (1) -- LEVEL: Main Floor LOADING: ASD MEMBER NAME: FB4 CODE: 2021 International Building Code MEMBER TYPE: FLOOR BEAM NDS: 2018 NDS MATERIAL: Solid Sawn Douglas Fir-Larch No. 2 (1) 2 X 3 DRY FB4 DIAGRAM BEAM PROPERTIES Start (ft): 0 End (ft): 2.5 Member Slope (in): 0/12 Actual Length (ft): 2.5 Area Ix Iy BSW Lams G Kcr (in²) (in⁴) (in⁴) (lbf/ft) Creep Factor 6 4.5 2 1.37 1 0.5 1 STRENGTH PROPERTIES Fb (psi) Ft (psi) Fv (psi) Fc (psi) Fc⊥(psi) E (psi) x10³ Emin (psi) x10³ Base Values 900 575 180 1350 625 1600 580 Adjusted Values 1350 862 180 1552 625 1600 580 C M 1 1 1 1 1 1 1 C T 1 1 1 1 1 1 1 C i 1 1 1 1 1 1 1 C F 1.5 1.5 1 1.15 1 1 1 Bending Adjustment Factors C fu = 1 C r = 1 BEAM DATA Unbraced Length (ft) Beam End Span Length (ft) Top Bottom Elev. Diff (ft) CL(Top) CL(Bottom) CL(Left) CL(Right) 1 2.5 0 2.5 0 PASS-FAIL Shear Stress Y (psi) Bending Stress Y (psi) Deflection Y (in) Bearing Stress (psi) PASS/FAIL PASS (68.5%) PASS (58.0%) PASS (76.6%) PASS (94.0%) MAGNITUDE 56.7 566.8 0.020 37.8 STRENGTH 180.0 1350.0 0.083 (=L/360) 625.0 LOCATION (ft) 0 1.25 1.25 0 LOAD COMBO D+L D+L L D+L DURATION FACTOR CD 1 1 1 REACTIONS Units for V: lbf Units for M: lbf-ft DEAD LIVE TOTALY axis A 27 200 227 B 27 200 227 Reaction Location A B Page 15 2021 International Building Code ASDPROJECT: Moon-Pavilion (1) Page 19 LOAD LIST Type Name Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Uniform (lbf/ft) w_D 20 20 0 2.5 Dead Y Uniform (lbf/ft) w_L 160 160 0 2.5 Live Y Self Weight (lbf/ft)-1.37 1.37 0 2.5 Dead Y Page 16 2021 International Building Code ASDPROJECT: Moon-Pavilion (1) Member Name: FB4 Page 20 PASS DATE: 7/9/2025 COMPANY: PBD Inc STRUCALC BUILD: StruCalc Pro DESIGNED BY: Bach Nguyen CUSTOMER: REVIEWED BY: Tung Vo PROJ. ADDRESS: -- PROJECT NAME: Moon-Pavilion (1) -- LEVEL: Main Floor LOADING: ASD MEMBER NAME: FB5 CODE: 2021 International Building Code MEMBER TYPE: FLOOR BEAM NDS: 2018 NDS MATERIAL: Solid Sawn Douglas Fir-Larch No. 2 (1) 4.5 X 5 DRY FB5 DIAGRAM BEAM PROPERTIES Start (ft): 0 End (ft): 5.25 Member Slope (in): 0/12 Actual Length (ft): 5.25 Area Ix Iy BSW Lams G Kcr (in²) (in⁴) (in⁴) (lbf/ft) Creep Factor 22.5 46.88 37.97 5.13 1 0.5 1 STRENGTH PROPERTIES Fb (psi) Ft (psi) Fv (psi) Fc (psi) Fc⊥(psi) E (psi) x10³ Emin (psi) x10³ Base Values 750 475 170 700 625 1300 470 Adjusted Values 750 475 170 700 625 1300 470 C M 1 1 1 1 1 1 1 C T 1 1 1 1 1 1 1 C i 1 1 1 1 1 1 1 C F 1 1 1 1 1 1 1 Bending Adjustment Factors C fu = 1.05 C r = 1 BEAM DATA Unbraced Length (ft) Beam End Span Length (ft) Top Bottom Elev. Diff (ft) CL(Top) CL(Bottom) CL(Left) CL(Right) 1 5.25 0 5.25 0 PASS-FAIL Shear Stress Y (psi) Bending Stress Y (psi) Deflection Y (in) Bearing Stress (psi) PASS/FAIL PASS (79.0%) PASS (20.1%) PASS (68.2%) PASS (93.7%) MAGNITUDE 35.7 599.4 0.056 39.6 STRENGTH 170.0 750.0 0.175 (=L/360) 625.0 LOCATION (ft) 5.25 2.993 2.678 5.25 LOAD COMBO D+L D+L L D+L DURATION FACTOR CD 1 1 1 REACTIONS Units for V: lbf Units for M: lbf-ft DEAD LIVE TOTALY axis A 89 381 470 B 96 439 535 Reaction Location A B Page 17 2021 International Building Code ASDPROJECT: Moon-Pavilion (1) Page 21 LOAD LIST Type Name Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Uniform (lbf/ft) w_D 20 20 0 5.25 Dead Y Uniform (lbf/ft) Uniform 80 80 0 5.25 Live Y Self Weight (lbf/ft)-5.13 5.13 0 5.25 Dead Y Linked Load List Type Member Support Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Point (lbf) FB4 A 26.71052 - 3 -Dead Y Point (lbf) FB4 B 26.71053 - 3 -Dead Y Point (lbf) FB4 A 200 - 3 -Live Y Point (lbf) FB4 B 200 - 3 -Live Y Page 18 2021 International Building Code ASDPROJECT: Moon-Pavilion (1) Member Name: FB5 Page 22 PASS DATE: 7/9/2025 COMPANY: PBD Inc STRUCALC BUILD: StruCalc Pro DESIGNED BY: Bach Nguyen CUSTOMER: REVIEWED BY: Tung Vo PROJ. ADDRESS: -- PROJECT NAME: Moon-Pavilion (1) -- LEVEL: Main Floor LOADING: ASD MEMBER NAME: FB6 CODE: 2021 International Building Code MEMBER TYPE: FLOOR BEAM AISC: AISC 360-16 MATERIAL: Steel HSS Rectangular HSS4x3x.313 A500 Gr.B-46 FB6 DIAGRAM BEAM PROPERTIES Start (ft): 0 End (ft): 11 Member Slope (in): 0/12 Actual Length (ft): 11 Es x10³ Fy x10³ Fu x10³ Area Ix Iy Zx Zy J Cw (psi) (psi) (psi) (in²) (in⁴) (in⁴) (in³) (in³) (in⁴) (in⁶) 29000 46 58 3.52 7.14 4.52 4.51 3.69 9.41 0 DESIGN PROPERTIES Lp Lr Flange Web Flange Web (in) (in) Flexure Flexure Compression Compression Cv Cv_WA 118 3281 Compact Compact Non-Slender Non-Slender 1 1 BEAM DATA Unbraced Length Beam End Span Length (ft) Top Bottom Elev. Diff Pnt/Ω Pnc/Ω Mn/Ω Mn-OOP/Ω Vn/Ω Vn-OOP/Ω Cb Cb-OOP 1 11 0 11 0 0 0 0 0 0 0 0 0 PASS-FAIL Shear Force Y (lbf) Moment Y (lbf-ft) Deflection Y (in) PASS/FAIL PASS (94.0%) PASS (25.0%) PASS (22.0%) MAGNITUDE 1817.7 7763.5 0.572 STRENGTH 30106.5 10352.3 0.733 (=L/180) LOCATION (ft) 0 5.5 5.5 AISC CODE G4-1 F7-1 LOAD COMBO D+L D+L L REACTIONS Units for V: lbf Units for M: lbf-ft DEAD LIVE TOTALY axis A 338 1480 1818 B 338 1480 1818 Reaction Location A BLOAD LIST Type Name Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Uniform (lbf/ft) w_D 15 15 0 11 Dead Y Uniform (lbf/ft) w_L 120 120 0 11 Live Y Self Weight (lbf/ft)-12.7 12.7 0 11 Dead Y Page 19 2021 International Building Code ASDPROJECT: Moon-Pavilion (1) Page 23 Linked Load List Type Member Support Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Point (lbf) FB5 A 88.86513 -5.5 -Dead Y Point (lbf) FB5 A 88.86513 -5.5 -Dead Y Point (lbf) FB5 B 96.49672 -5.5 -Dead Y Point (lbf) FB5 B 96.49672 -5.5 -Dead Y Point (lbf) FB5 A 381.4286 -5.5 -Live Y Point (lbf) FB5 A 381.4286 -5.5 -Live Y Point (lbf) FB5 B 438.5713 -5.5 -Live Y Point (lbf) FB5 B 438.5713 -5.5 -Live Y Page 20 2021 International Building Code ASDPROJECT: Moon-Pavilion (1) Member Name: FB6 Page 24 STRUCTURAL ANALYSIS (Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code) Job Number: 25049 Plan: General Information: Soil bearing Pressure = 1500 psf SDS =1.06 R = 2.5 Ie =1 Cs = (SDS x Ie) / R / 1.4 =0.30 Roof Dead Load = 13.5 psf Floor Dead Load = 10 psf Wind calculation: (Open Building ASCE 7-16 Section 27.3.2) Exposure = C Wind speed = 95 mph Mean Roof Height = 19 ft Kzt = 1.00 Kd = 0.85 Ke = 1 Iw = 1 q = 0.00256 x Kh x Kzt x Kd x V2 x Iw Level H Kh q A (sf)F (lbs) Roof 19.5 0.91 17.91 36 644.77 Floor 7 0.7 13.75 10 137.47 Seismic Analysis: V=Cs * W Roof Area = 115 sf Floor area = 115 sf Level W (lb) H (ft)W*H V (lbs) Roof 1552.5 19.5 30273.75 0.79 646.55 Floor 1150 7 8050 0.21 171.92 Sum 2702.5 38323.75 Summary Level Wind (lbs) Seismic (lbs) Roof 644.77 646.55 Seismic govern Floor 137.47 171.92 Seismic govern Lateral @ Each Post # of Post : 6 Lateral Load @ Each Post : Level Wind (lbs) Seismic (lbs) Roof 107.46 107.76 Seismic govern Floor 22.91 28.65 Seismic govern Page 25 PASS DATE: 7/9/2025 COMPANY: PBD Inc STRUCALC BUILD: StruCalc Pro DESIGNED BY: Bach Nguyen CUSTOMER: REVIEWED BY: Tung Vo PROJ. ADDRESS: -- PROJECT NAME: Moon Pavilion -- LEVEL: Column LOADING: ASD MEMBER NAME: CL1 CODE: 2021 International Building Code MEMBER TYPE: COLUMN AISC: AISC 360-16 MATERIAL: Steel HSS Round HSS4X.313 A500 Gr.C-46 CL1 DIAGRAM COLUMN PROPERTIES Start (ft): 0 End (ft): 16 Es x10³ Fy x10³ Fu x10³ Area I Z J Cw (psi) (psi) (psi) (in²) (in⁴) (in³) (in⁴) (in⁶) 29000 46 62 3.39 5.87 4.01 11.7 5.87 DESIGN PROPERTIES Lp Lr Flange Web Flange Web (in) (in) Flexure Flexure Compression Compression Cv Cv_WA 0 0 Compact Compact Non-Slender Non-Slender 0 0 COLUMN DATA Unbraced Length Column End Span Length (ft) Top Bottom Elev. Diff Pnt/Ω Pnc/Ω Mn/Ω Mn-OOP/Ω Vn/Ω Vn-OOP/Ω Cb Cb-OOP 1 16 0 0 0 0 0 0 0 0 0 0 0 PASS-FAIL Shear Force Y (lbf) Moment Y (lbf-ft) Deflection Y (in) Compressive Force (lbf) Bending-Compression (Unit) PASS/FAIL PASS (99.7%) PASS (79.2%) PASS (77.7%) PASS (90.1%) PASS (77.6%) MAGNITUDE 95.2 1915.8 0.357 2158.2 0.22 STRENGTH 28013.2 9204.6 1.600 (=L/240) 21844.8 1.00 LOCATION (ft) 0 0 16 0 0 AISC CODE G5-1 F8-1 E3-1 H1-1b LOAD COMBO D+0.7E(+) D+0.7E(+) Lr D+L D+0.7E(+) REACTIONS Units for V: lbf Units for M: lbf-ft DEAD LIVE LIVE ROOF SEISMIC + TOTALZ axis A 678 1480 188 0 2346 B 0 0 0 0 0 Y axis A 0 0 0 136 136 B 0 0 0 0 0 M@x A 555 0 275 1944 2774 B 0 0 0 0 0 Reaction Location A B Page 21 2021 International Building Code ASDPROJECT: Moon Pavilion Page 26 LOAD LIST Type Name Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Point (lbf) Point 107 -16 -SeismicPlus Y Point (lbf) Point 29 - 8 -SeismicPlus Y Moment (lbf-ft) Moment -555 -16 -Dead Y Moment (lbf-ft) Moment -275 -16 -RoofLive Y Self Weight (lbf/ft)-12.34 12.34 0 16 Dead Z Linked Load List Type Member Support Left Magnitude Right Magnitude Load Start (ft) Load End (ft) Load Type Direction Axial (lbf) RB1 A -143.0263 -143.0263 16 16 Dead Z Axial (lbf) RB1 A -187.5 -187.5 16 16 RoofLive Z Axial (lbf) FB6 A -337.7118 -337.7118 16 16 Dead Z Axial (lbf) FB6 A -1480 -1480 16 16 Live Z Page 22 2021 International Building Code ASDPROJECT: Moon Pavilion Member Name: CL1 Page 27 Project: Engineer: Descrip: TUNG VO 25049 Page # ___ 7/20/2025 ASDIP Steel 6.3.2.5 BASE PLATE / ANCHORAGE DESIGN www.asdipsoft.com GEOMETRY Column Section .................HSS4.000X0.313 Width Length Column .......... Plate .............. Concrete Support Rod Edge ....... Thickness of Grout ............ Wp1 Wp2 Lp1 Lp2 4.0 4.0 12.0 12.0 12.0 12.0 12.0 12.0 1.5 1.5 1.0 in in in in in in OK OK OK OK MATERIALS Plate Steel Strength Fy ...... Pier Concrete Strength f'c .. 36.0 3.0 ksi ksi Plate Allowed to Work in Plastic Range (Mn = Mp) APPLIED LOADS Dead Live RLive Snow Wind Seismic Vertical Load P ............ Bending Moment Mx ... Bending Moment Mz ... Horizontal Load Vx ...... Horizontal Load Vz ...... 3.0 0.0 0.0 0.0 0.0 2.0 0.0 0.0 0.0 0.0 1.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 2.0 2.0 0.0 0.0 kip k-ft k-ft kip kip Design spectral acceleration Sds =1.10 Overstrength seismic factor Ωo =1.25 - Seismic tension:Non-yielding base plate / Non-yielding anchorage ACI 17.10.5.3 (d) Tension per rod due to 1.0E alone =2.2 kip 1.116D+0.75L+0.75S+0.525E = 0.2 kip (0.53 * 2.2 = 1.1 kip > 0.2 * 0.20 = 0.0 kip) , Apply seismic provisions ACI 17.10.5.1 - Seismic shear:Non-yielding base plate / Non-yielding anchorage ACI 17.10.6.3 (c) Shear per rod due to 1.0E alone = 0.0 kip 1.154D+0.7E = 0.0 kip (0.70 * 0.0 = 0.0 kip < 0.0 * 0.20 = 0.0 kip) , Ignore seismic provisions ACI 17.10.6.1 PLATE WITH MOMENTS Bearing Strength Fpn/Ω ........ 2.0 ksi - Comb. 0.446D+0.875E Max. Bearing Stress fp ......... X-Moment due to Bearing ..... Z-Moment due to Bearing ..... X-Moment per Rod Tension .. Z-Moment per Rod Tension .. Plate Thickness Reqd. tp ..... Use Plate Thickness tp ........ 0.3 1.0 1.0 0.0 0.8 0.42 0.75 ⬅ ksi k-in/in k-in/in k-in/in k-in/in in in OK OK AXIALLY LOADED PLATE - Comb. 0.446D+0.875E Uniform Bearing Stress fp .... X-Critical Section m .............. Z-Critical Section n ............... Int. Critical Section λn' .......... Moment due to Bearing ......... Moment due to Rod Tension . Plate Thickness Reqd. tp ..... 0.0 4.4 4.4 N.A 0.1 0.0 0.13 ksi in in k-in/in k-in/in in OK DESIGN CODES Steel Design ........................AISC 360-16 Anchorage Design ...............ACI 318-19 Load Combinations ..............ASCE 7-10/16 1 of 3 Page 28 Project: Engineer: Descrip: TUNG VO 25049 Page # ___ 7/20/2025 ASDIP Steel 6.3.2.5 BASE PLATE / ANCHORAGE DESIGN www.asdipsoft.com ANCHORAGE DESIGN Rod Material Specification ......... Anchor Rod Size .. F1554-36 (4) Rods , fya = 36.0 ksi, futa = 58.0 ksi 3/4" diam. x 9.0 in emb. Concrete Is Cracked at Service Load Level Tension Analysis (kip) - Comb. 0.446D+0.875E - Design per ACI 17.2.3.4.2 (d) for Ωo = 1.25 Total Tension Force N .......... Tension Force per Rod Ni .... Supplementary Reinforcement Provided 2.4 1.6 kip kip Failure Mode Ω Nn N / Nn/Ω Steel Strength Nsa Rebars Strength Nrg Conc. Breakout Ncbg Pullout Strength Npn Side Blowout Nsbg N / Nn/Ω Tension Design Ratio ....OK 2.00 2.00 2.00 2.00 2.00 19.4 N.A. 32.3 21.9 N.A. 0.16 N.A. 0.19 0.19 N.A. 0.19 ⬅ Shear Analysis (kip) - Comb. 0.6D+0.7E Shear Taken by Anchor Rods only Total Shear Force V ...........0.0 kip Shear Force per Rod Vi ...... 0.0 kip Only Front Rods Are Effective Anchor Reinf: Use Hairpins #4 per Rod Failure Mode Ω Vn V / Vn/Ω Steel Strength Vsa Rebars Strength Vrg Conc. Breakout Vcbg Conc. Pryout Vcpg 2.31 2.00 2.00 2.00 9.3 48.0 N.A. 0.0 0.00 0.00 N.A. 0.00 ⬅ 0.00V / Vn/Ω Shear Design Ratio ......OK Tension-Shear Interaction - Comb. 0.446D+0.875E Combined Stress Ratio ........... 0.19 OK DESIGN IS NON-DUCTILE DESIGN CODES Steel Design ........................AISC 360-16 Anchorage Design ...............ACI 318-19 Load Combinations ..............ASCE 7-10/16 2 of 3 Page 29 Project: Engineer: Descrip: TUNG VO 25049 Page # ___ 7/20/2025 ASDIP Steel 6.3.2.5 BASE PLATE / ANCHORAGE DESIGN www.asdipsoft.com Tension Breakout Shear Breakout 3 of 3 Page 30 Foundation Soil Pressure Diagram (enve) [lb/ft2] Page 31 LRFD Foundation Top and Bottom Reinforcement (Enveloping Flexural) Page 32 Number: 412 Originally Issued: 07/31/2015 Revised: 07/08/2025 Valid Through: 07/31/2026 The product described in this Uniform Evaluation Service (UES) Report has been evaluated as an alternative material, design or method of construction in order to satisfy and comply with the intent of the provision of the code, as noted in this report, and for at least equivalence to that prescribed in the code in quality, strength, effectiveness, fire resistance, durability and safety, as applicable, in accordance with IBC Section 104.11. This document shall only be reproduced in its entirety. 5 by International Association of Plumbing and Mechanical Officials. All rights reserved. Printed in the United States. Ph: 1-877-4IESRPT • Fax: 909.472.4171 -es.org • 4755 East Philadelphia Street, Ontario, California 91761-2816 – USA Page 1 of 7 WESTLAKE ROYAL ROOFING LLC 2801 Post Oak, Suite 600 Houston, TX 77056 800.669.8453 www.WestlakeRoyalRoofing.com IAPMO UES ER-412 Scope of Evaluation Report – ER 412 1.0 RECOGNITION This report describes the results of research completed by IAPMO Uniform Evaluation Service on Newpoint Concrete Roof Tiles to assess conformance to the codes shown at the beginning of this report and serves as documentation of the product certification. Products are manufactured under a quality control program with periodic inspection under the supervision of IAPMO UES. The Newpoint Concrete Roof Tiles recognized in this report are manufactured in Lake Wales, FL; Brookshire, TX; Phoenix, AZ; Henderson, NV; Okeechobee, FL; Rialto, CA; French Camp, CA; Henderson, CO; and Lathrop, CA. Tables 2A through 2H describe the tiles produced at each location. 2.0 PRODUCT DESCRIPTION AND FIELD IDENTIFICATION OF NEWPOINT CONCRETE ROOF TILES Newpoint Concrete Roof Tiles are manufactured in multiple collections defined in Tables 2A through 2H of this report. Each collection differs in colors, blends, textures and architectural themes. Shipping pallets are identified with the report holder’s name (Westlake Royal Roofing), manufacturing address, product name, installed weight, inspection agency, and evaluation report number (ER-412). The Cedarlite 600, Madera 700, and Madera 900 tiles are imprinted on the top side of each tile with an “M”, all other field tiles are imprinted with the name “BORAL”, “Westlake Royal Roofing”, “Westlake Royal Roofing Lifetile”, “Monierlifetile”, Westlake Royal Roofing Newpoint Concrete Roof Tiles and EnviroPro Component CSI Category: 07 32 16 Concrete Roof Tiles Evaluated Properties International Building Code® (IBC) 2021, 2018, 2015, 2012, 2009, and 2006 Quality Strength Effectiveness Fire Resistance Durability Safety International Residential Code® (IRC) 2021, 2018, 2015, 2012, 2009, and 2006 California Building Code (CBC) – Supplement attached 2022 2022 2023 2023 (Newest code references only in this IBC: 104.11, 1504.3, 1505.2, 1507.3.5, 1507.3.5 IRC: R104.11, R903, R905.3.4, R902 Evaluated Properties Fire Classification, Weather Resistance, Wind Resistance Number: 412 Originally Issued: 07/31/2015 Revised: 07/08/2025 Valid Through: 07/31/2026 Page 2 of 7 or the “Westlake Royal Roofing”, or “MonierLifetile” or “Vostile” name or logo. The Westlake Royal Roofing EnviroPro product shall be clearly identified to provide distinction between field tiles and component tiles as stated in the EnviroPro product installation guidelines. 3.0 EVALUATION OF NEWPOINT CONCRETE ROOF TILES TO REFERENCED CODES AND STANDARDS The weather resistance, wind resistance, and fire classification properties of the roof tiles comply with the intent of the provisions of the codes and regulations defined in this report. Newpoint Concrete Roof Tiles, when used as a roof covering, meet the performance requirements as defined by Section 1504.3 of the IBC or Section 903 of the IRC. 3.1 Installation Requirements and Limitations: Newpoint Concrete Roof Tiles shall be installed in accordance with the manufacturer’s installation instructions, this evaluation report and the applicable code. Where conflicts occur between these provisions, the code shall apply in accordance with Section 102.4.1 of the IBC. Concrete roof tiles have been evaluated to be installed on roof slopes of 2½ units vertical in 12 units horizontal (21 percent slope) or greater as defined by Section 1507.3.2 of the IBC. 3.1.1 Installation in Accordance with the 2021 and 2018 IBC or IRC: Newpoint Concrete Roof Tiles installation shall comply with the provisions of IBC Section 1507.3 and IRC Section R905.3, including the attachment requirements of IBC Section 1507.3.7 or IRC Section R905.3.7, as applicable. Underlayment shall conform to IBC Section 1507.1.1 or IRC Section R905.1.1, as applicable. The installation of component tiles, EnviroPro®, is detailed in Section 3.1.4. 3.1.2 Installation in Accordance with the 2015, 2012, 2009, or 2006 IBC or IRC: Newpoint Concrete Roof Tiles shall be fastened in accordance with the code specific requirements in Table 1 of this report using The Concrete and Clay Roof Tile Installation Manual for Moderate Climate Regions, dated July 2015, published by the Tile Roofing Institute and the Western States Roofing Contractors Association. The July 2015 TRI manual is associated with ER-2015 in the UES Evaluation Report Directory and available for download at www.uniform-es.org. Installation of component tiles, EnviroPro®, is detailed in Section 3.1.4 of this report. 3.1.3 Bedding and Adhesive Requirements: Newpoint Concrete Roof Tiles may be adhered using mortar in accordance with the applicable building code and, where permitted, the TRI Manual or adhesively attached in accordance with the adhesive manufacturer’s current research report issued by an approved evaluation service agency. 3.1.4 Installation of EnviroPro Component: EnviroPro component product shall be limited to installation where roof tiles must be cut, such as in valleys and boundary edges at rakes, walls, chimney, skylights, and other roof openings and penetrations. The installed dry weight of Westlake Royal Roofing EnviroPro is equivalent to that of the tile profile in Tables 2A-2H with which it is used. 3.2 Design Requirements and Limitations: Westlake Royal Newpoint Concrete Roof Tiles have been evaluated to meet the design requirements of this section. Design shall consider the tile installed dry weight, dimensions, and tile factors as defined in Tables 2A-2H of this report. 3.2.1 Strength, Durability. and Effectiveness: Newpoint Concrete Roof Tiles comply with ASTM C1492 as required by Section 1507.3.5 of the IBC. 3.2.2 Fire Resistance and Safety: Newpoint Concrete roof tiles installed on an assembly which uses a minimum 15/32-inch-thick (12 mm) plywood solid sheathing or a non-combustible deck, achieve an ASTM E108 Class A rating per Section 1505.2 of the IBC and Section R902.1 of the IRC, as applicable. Roof fire classifications and conditions of use for adhered tiles shall be in accordance with the current evaluation report of the roof tile adhesive and be approved by the local building official. 4.0 REFERENCES Data in accordance with ICC-ES AC180, manufacturer’s descriptive literature, and installation instructions. Test reports are from laboratories in compliance with ISO/IEC 17025. For additional information about this evaluation report please visit www.uniform -es.org or email us at info@uniform-es.org Number: 412 Originally Issued: 07/31/2015 Revised: 07/08/2025 Valid Through: 07/31/2026 Page 3 of 7 TABLE 1 – Attachment Design Applicable Code Criteria for Applicability Design Information Location 2015 or 2012 IBC ult ≤ 130 mph and Mean Roof Height ≤ 60 feet Roof Tile Installation Manual & Table 1507.3.7 of the applicable IBC 2009 or 2006 IBC ≤ 100 mph and Height ≤ 60 feet Mean Roof Height ≤ 40 feet SI: TABLE 2B - Tiles Manufactured at Henderson, NV Tile Installed Dry Weight1 (psf) (inch)Tile Factor Length X Width TF (ft3) Ratio 1 Espana / Barcelona 9.0 17 X 123/8 1.470 1.045 Saxony 900 – Shake, Slate, Country Slate 9.1 17 X 13 1.533 1.090 For SI: 1 inch = 25.4 mm, 1 psf = 4.88 kg/m2 TABLE 2A - Tiles Manufactured at Denver (Henderson), CO Tile Installed Dry Weight1 (psf) (inch)Tile Factor Length X Width TF (ft3) Ratio 1 Madera 900 7.9 13½ X 13 0.947 0.673 Saxony – Shake, Slate, Country Slate Split Old English Thatch 9.6 17 X 13 1.568 1.115 For SI: 1 inch = 25.4 mm, 1 psf = 4.88 kg/m2 Number: 412 Originally Issued: 07/31/2015 Revised: 07/08/2025 Valid Through: 07/31/2026 Page 4 of 7 TABLE 2C - Tiles Manufactured at Katy (Brookshire), TX Tile Installed Dry Weight1 (psf) (inch)Tile Factor Length X Width TF (ft3) Ratio 1 Barcelona – Impact 10.3 16½ X 13 1.444 1.027 Saxony – Country Shake, Country Slate, Country Split Shake, English 10.3 16½ X 13 1.392 0.989 SI:2 1 Used on a 3-inch head-lap 2 Nominal dimension. TABLE 2D - Tiles Manufactured at Lake Wales, FL Tile Installed Dry Weight1 (psf) (inch)Tile Factor Length X Width TF (ft3) Ratio 1 Barcelona 900 9.5 17 X 13 1.525 1.084 Saxony 900 – Shake, Slate, Split Shake, Country Slate 9.5 17 X 13 1.545 1.098 SI: TABLE 2E - Tiles Manufactured at Lathrop, CA Tile Installed Dry Weight1 (psf) (inch)Tile Factor Length X Width TF (ft3) Ratio 1 Barcelona 900 9.3 17 X 13 1.509 1.073 Saxony 900 – Shake, Slate 9.1 17 X 13 1.533 1.090 Saxony 900 - Hartford Slate, Country Slate 9.1 17 X 13 1.533 1.090 9.8 17 X 13 1.533 1.090 SI: TABLE 2F - Tiles Manufactured at Phoenix, AZ Tile Installed Dry Weight1 (psf) (inch)Tile Factor Length X Width TF (ft3) Ratio 1 Mission S / Barcelona 10.3 16½ X 13 1.494 1.062 Saxony – Shake, Slate 9.5 16½ X 13 1.494 1.062 Villa 9.0 16½ X 13 1.407 1.000 For 1 inch = 25.4 mm, 1 psf = 4.88 kg/m2 Number: 412 Originally Issued: 07/31/2015 Revised: 07/08/2025 Valid Through: 07/31/2026 Page 5 of 7 TABLE 2G - Tiles Manufactured at Okeechobee, FL Tile Installed Dry Weight1 (psf) (inch)Tile Factor Length X Width TF (ft3) Ratio 1 Bermuda 12.44 161/8 X 101/8 1.036 0.736 Estate “S” 7.9 16½ X 13 1.417 1.007 Galena Spanish “S” 9.3 17 X 10 1.144 0.831 Plantation 10.4 16½ X 13 1.426 1.014 Saxony 900 9.3 17 X 13 1.533 1.090 For 1 inch = 25.4 mm, 1 psf = 4.88 kg/m2 1 Used on a 3-inch head-lap 2 TABLE 2H - Tiles Manufactured at Rialto, CA Tile Installed Dry Weight1 (psf) (inch)Tile Factor Length X Width TF (ft3) Ratio 1 Espana / Barcelona 9.0 17 X 13 1.533 1.090 Espana 600 / Barcelona 600 5.9 17 X 13 1.533 1.090 Saxony 600 - Slate, Shake, Split Shake 5.9 17 X 13 1.533 1.090 7.1 17 X 13 1.533 1.090 9.3 17 X 13 1.533 1.090 For SI: 1 inch = 25.4 mm, 1 psf = 4.88 kg/m2 Number: 412 Originally Issued: 07/31/2015 Revised: 07/08/2025 Valid Through: 07/31/2026 Page 6 of 7 CALIFORNIA SUPPLEMENT WESTLAKE ROYAL ROOFING LLC 2801 Post Oak, Suite 600 Houston, TX 77056 800.669.8453 www.WestlakeRoyalRoofing.com CONCRETE ROOF TILES CSI Section: 07 32 16 Concrete Roof Tiles 1.0 RECOGNITION The Westlake Royal Roofing Newpoint (Newpoint) Concrete Roof Tiles and components evaluated in IAPMO UES ER-412 are satisfactory alternative roof covering materials in accordance with the following codes and regulations: • 2022 California Building Code (CBC) • 2022 California Residential Code (CRC) 2.0 PRODUCT USE 2.1 The Newpoint Concrete Roof Tiles may be used as a Class A, B, or C roof covering system complying with Section 1505.1.1 of the CBC or Section R902.1.1 of the CRC; Section 1505.1.2 of the CBC or Section R902.1.2 of the CRC; or Section 1505.1.3 of the CBC or Section R902.1.3 of the CRC, respectively. The design and installation of the Newpoint Concrete Roof tiles shall be in accordance with Sections 1507.3.10 and 1513 of the CBC or Section 905.3 of the CRC, as applicable, and ER-412. 2.2 Roof Tiles shall be installed in accordance with Sections 3.0 and 4.0 of ER-412 except, where the building official requires conformance to the CBC or CRC, the following shall be substituted: 2.2.1 Underlayment shall conform with CBC Section 1507.1.1 or CRC Section 905.1.1, as applicable. 2.2.2 Attachment of the concrete roof tiles shall be designed to resist wind loads according to CBC Sections 1507.3.7 and 1609.5 or CRC Section 905.3, as applicable. 2.3 Newpoint Concrete Roof Tiles may be used in “new buildings located in any Fire Hazard Severity Zone, or any Wildland-Urban Interface Fire Area designated by the enforcing agency constructed after the application date shall comply with the provisions” in accordance with Sections 701A.3 and 705A of the CBC, or Sections R337.1.3.1 and R337.5 of the CRC, as applicable, and with the IBC as presented in ER-412. 2.4 Newpoint Concrete Roof Tiles used on structures regulated by the Division of the State Architect, or the Office of Statewide Planning and Development are subject to installation provisions in CBC Section 1513. 2.5 This supplement expires concurrently with ER-412. For additional information about this evaluation report please visit www.uniform-es.org or email us at info@uniform -es.org Number: 412 Originally Issued: 07/31/2015 Revised: 07/08/2025 Valid Through: 07/31/2026 Page 7 of 7 FLORIDA SUPPLEMENT WESTLAKE ROYAL ROOFING LLC 2801 Post Oak, Suite 600 Houston, TX 77056 800.669.8453 www.WestlakeRoyalRoofing.com CONCRETE ROOF TILES CSI Section: 07 32 16 Concrete Roof Tiles 1.0 RECOGNITION The Westlake Royal Roofing Newpoint Concrete Roof (Newpoint) tiles and component evaluated in IAPMO UES ER-412 are satisfactory alternative roof covering materials in accordance with to the following codes and regulations: • 2023 Florida Building Code, Building (FBC, Building) • 2023 Florida Building Code, Residential (FBC, Residential) 2.0 LIMITATIONS Use of the Newpoint Roofing Concrete Roof Tiles recognized in this report supplement is subject to the following limitations: 2.1 Verification shall be provided that a quality assurance agency audits the manufacturers’ quality assurance program and audits the production quality of products, in accordance with Section (5)(d) of Florida Rule 61G20-3.008. The quality assurance agency shall be approved by the Commission (or the building official when the report holder does not possess an approval by the Commission). 2.2 Evaluation to the high-velocity hurricane zone provisions in Section 1512 of the FBC, Building, and Chapter 44 of the FBC, Residential, is beyond the scope of this report. 2.3 This supplement expires concurrently with ER-412. 3.0 PRODUCT USE The design and installation of the Newpoint Concrete Roof Tiles shall be in accordance with the 2021 International Building Code and the 2021 International Residential Code, as applicable, as noted in ER-412. The FBC, Building, Section 1507.3 and FBC, Residential, Section R905.3 states that the installation of the Newpoint Concrete Roof Tiles “shall be in accordance with the requirements of the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth or Seventh Edition, as applicable, where the Vasd is determined in accordance with” FBC, Building, Section 1609.3.1; FBC, Residential, Section R301.2.1.3; or the recommendations of RAS 118, 119, or 120. Load combinations shall be in accordance with Sections 1605.1 and 1605.2 of the 2023 FBC, Building, as applicable. Design wind loads shall be in accordance with Section 1609.6 of the 2023 FBC, Building, or Section R301.2.1 of the FBC, Residential, as applicable. For additional information about this evaluation report please visit www.uniform-es.org or email us at info@uniform -es.org