HomeMy WebLinkAbout1900 E Deere Ave - PlanPREPARED BY: LOCATION MAP SCALE: NTS RED BULL - ELECTRADA EV CHARGING - SANTA ANA 1900 EAST DEERE AVE, SANTA ANA, CA 92705 NSCOPE OF WORK: THIS PROJECT INVOLVES THE INSTALLATION OF SIX (6) 48A, LEVEL 2 EV CHARGERS. THE DESIGN INCLUDES DISTRIBUTION FROM A NEW PANEL FED FROM AN EXISTING UTILITY SERVICE AND ASSOCIATED INFRASTRUCTURE TO SUPPORT THE INSTALLATION. SYSTEM OWNERS: ELECTRADA 231 W 12TH ST SUITE 600 CINCINNATI, OH 45202 (513) 632-0360 CIVIL ENGINEER: DAVID HILLEY BURNS ENGINEERING, INC. 300 NORTH CONTINENTAL BLVD SUITE 540 EL SEGUNDO, CA 90245 213-344-4699 AUTHORITY HAVING JURISDICTION: CITY OF SANTA ANA GENERAL COMPLIANCE - CA DESIGN AND PERFORMANCE OF COMPONENTS AND METHODS SPECIFIED HEREIN SHALL COMPLY WITH THE LATEST ADOPTED VERSIONS OF THE STATE OF CALIFORNIA CODES, AND THE LOCAL AUTHORITIES HAVING JURISDICTION INCLUDING BUT NOT LIMITED TO: ·TITLE 24 CALIFORNIA CODE OF REGULATIONS ·2021 IBC INTERNATIONAL BUILDING CODE ·2021 IECC INTERNATIONAL ENERGY CONSERVATION CODE ·2020 NFPA 70 NATIONAL ELECTRICAL CODE ·2022 NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE ·2018 NFPA 101 LIFE SAFETY CODE ·2020 NFPA 70E STANDARD FOR ELECTRICAL SAFETY IN THE WORKPLACE ·2020 NFPA 110 STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS ·2023 NESC NATIONAL ELECTRICAL SAFETY CODE ·2022 CEC CALIFORNIA ELECTRICAL CODE ·2022 BUILDING ENERGY EFFICIENCY STANDARDS ·2022 CBC CALIFORNIA BUILDING CODE PROPERTY DETAILS: ASSESSOR'S PARCEL NUMBER: 430-191-16 PROPERTY SIZE: 73,445.71 SQ. FT. BUILDING AREA: 22,022 SQ. FT. TYPE OF CONSTRUCTION PER C.B.C: TYPE III-B OCCUPANCY GROUP PER C.B.C: B AND S-1 NUMBER OF STORIES: 1 (1 STORY WAREHOUSE) SPRINKLERED: YES J: \ 2 0 2 4 b \ 2 0 2 4 - 0 0 6 7 . 1 1 - r e d _ b u l l _ e l e c t r a d a _ s a n t a _ a n a _ s t r u c t u r a l \ 1 0 - d e s i g n \ D r a w i n g s \ w o r k i n g d o c u m e n t s \ S H E E T S \ L A M I R A D A \ E L E C T R I C A L \ E V - 0 1 . d w g 2 0 2 6 - 0 2 - 0 9 Project Title: Drawing Title: RevisionDateNo. Date: Drawn: Checked: Job No: Scale: Drawing No: SHT:OF BURNS ENGINEERING, INC. | 310-439-5643 300 NORTH CONTINENTAL BLVD SUITE 540 EL SEGUNDO, CA 90245 RED BULL ELECTRADA STRUCTURAL DESIGN SANTA ANA 1 06/24/2025 CD30 ADDRESS: 1900 EAST DEERE AVE, SANTA ANA, CA 92705 ADDRESS: 3 2 07/02/2025 CD90 3 07/15/2025 ISSUE FOR PERMIT 4 11/03/2025 PLAN CHECK COMMENTS COVER SHEET 2/9/2026 AS NOTED CS IB 2024.0067.11 SEV-01 EV - 0 1 . D W G 1 EV ACCESSIBILITY: THE INSTALLATION OF (6) EV CHARGER IS FOR PRIVATE FLEET VEHICLES IS EXEMPT FROM THE REQUIREMENTS OF 2022 CBC 11B-228.3.2 PURSUANT TO EXCEPTION 1. Sheet List SHEET NUMBER DRAWING NUMBER DRAWING NAME 1 SEV-01 COVER SHEET 2 SEV-02 SITE PLAN 3 SEV-03 STRUCTURAL SITE PLAN DESIGN LOADS: SOIL SITE CLASS: D (DEFAULT) SEISMIC RESPONSE COEFFICIENTS SS = 1.265 S1 = 0.453 SMS = 1.518 SM1 = 0.86 SDS = 1.012 SD1 = 0.57 Ie = 1.0 IP = 1.0 (COMPONENTS IMPORTANCE FACTORS) DAVI D H I LLEY C97125 STATE OF CALIFORNIA L ICENSED PROFES S IONAL ENGINEER C I V I L 1 EV-02 SANTA ANA BUILDING PLAN N.T.S N J: \ 2 0 2 4 b \ 2 0 2 4 - 0 0 6 7 . 1 1 - r e d _ b u l l _ e l e c t r a d a _ s a n t a _ a n a _ s t r u c t u r a l \ 1 0 - d e s i g n \ D r a w i n g s \ w o r k i n g d o c u m e n t s \ S H E E T S \ L A M I R A D A \ E L E C T R I C A L \ E V - 0 2 . d w g 2 0 2 6 - 0 2 - 0 9 Project Title: Drawing Title: RevisionDateNo. Date: Drawn: Checked: Job No: Scale: Drawing No: SHT:OF BURNS ENGINEERING, INC. | 310-439-5643 300 NORTH CONTINENTAL BLVD SUITE 540 EL SEGUNDO, CA 90245 RED BULL ELECTRADA STRUCTURAL DESIGN SANTA ANA 1 06/24/2025 CD30 ADDRESS: 1900 EAST DEERE AVE, SANTA ANA, CA 92705 ADDRESS: 3 2 07/02/2025 CD90 3 07/15/2025 ISSUE FOR PERMIT 4 11/03/2025 PLAN CHECK COMMENTS SITE PLAN 2/9/2026 AS NOTED CS IB 2024.0067.11 SEV-02 EV - 0 2 . D W G 2 226FT 318FT 200FT 19FT 20FT (E) LANDSCAPE PLANTER (E) LANDSCAPE PLANTER PROPERTY FENCE LINE 119FT 191FT 9FT NO PARKING HANDICAP PARKING 217FT 533.0907 24FT 26FT CENTERLINE E DEERE AVE STREET (E) DRIVEWAY NO SIDEWALK 309FT EXISTING BUILDING AREA OF WORK NO WORK TO BE DONE IN HASHED AREAS NO WORK TO BE DONE IN HASHED AREAS 23FT 30FT 190FT 14FT PEDESTRIAN WALKWAY 27FT 8FT 32FT 97FT 181FT DAVI D H I LLEY C97125 STATE OF CALIFORNIA L ICENSED PROFES S IONAL ENGINEER C I V I L (N) EVSE-1 (N) EVSE-2 (N) EVSE-3 (N) EVSE-4 (N) EVSE-5 (N) EVSE-6 (E) MAIN SECTION CH2-1 UNUSED SERVICE DISCONNECT GARAGE ENTRANCE/EXIT (N) T-EVDP-1 (N) EVDP-1 M (N) EVDP-1 SUBMETER (E) UTILITY TRANSFORMER (N) 4" DIAMETER BOLLARD (E) COLUMN (TYP.) (E) FENCE (TYP.) (N) 4" DIAMETER BOLLARD (E) RACKING TO REMAIN (E) RACKING TO REMAIN (E) FENCE (TYP.) PARKING SPACE IS 11' x 24' (TYP.) 2" YELLOW SUPERIOR MARK FLOOR MARKING TAPE (TYP.) (N) 4" DIAMETER BOLLARD EV PEDESTAL EV PEDESTAL (TYP. FOR EVSE-1 THROUGH EVSE-5) (E) COMM ROOM 2" YELLOW SUPERIOR MARK FLOOR MARKING TAPE (TYP.) (E) OFFICE (E) RACKING TO REMAIN (E) RACKING TO REMAIN (N) STORAGE CABINET (N) DS-T1 1 SEV-03 SANTA ANA EV BUILDING PLAN 3/32" = 1'-0" GENERAL NOTES: 1.EVSE SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2.COORDINATE EVSE LOCATIONS WITH RESTRIPING PLAN. 3.ALL PENETRATIONS THROUGH CONCRETE STRUCTURAL FLOORING SHALL BE SCANNED WITH GROUND PENETRATING RADAR (GPR). SUBMIT FINDINGS TO ENGINEER FOR APPROVAL PRIOR TO PENETRATION. 4.THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, AND SITE CONDITIONS PRIOR TO THE START OF CONSTRUCTION AND NOTIFY THE ENGINEERING IMMEDIATELY OF ANY DISCREPANCIES OR INCONSISTENCIES. 5.FURNISH AND INSTALL STRIPPING FOR PARKING SPACES, UTILIZE SUPERIOR MARK FLOOR MARKING TAPE. COORDINATE EXACT DIMENSIONS AND LOCATIONS WITH RED BULL AND ELECTRADA. KEY NOTES: 1.MOUNT EVSE AND CABLE HOLSTER TO PEDESTAL. PEDESTAL HEIGHT 65". ANCHORS SHALL BE MIN 1/2" DIA HILTI KWIK BOLT TZ2 WITH 3.25" EMBED. SEE DETAIL 3/SEV-3. 2.CONTRACTOR SHALL PROVIDE BOLLARDS AS SHOWN FOR EACH COMPONENT BEING PROTECTED AS PER DETAIL 2/SEV-03. SUBMIT DETAILS PRIOR TO INSTALLATION. 3.EYEWASH STATION AND FORKLIFT CHARGER ARE CURRENTLY EXISTING IN THIS LOCATION, AND ARE BEING RELOCATED. (LOCATION TO BE DETERMINED). 4.FURNISH AND INSTALL TRANSFORMER EQUIPMENT. MAX WEIGHT OF EQUIPMENT 1000LB. ANCHOR PER MANUFACTURER RECOMMENDATIONS. ANCHORS SHALL BE KWICK BOLT TZ2 MIN 1/2" DIAMETER WITH 3.25" EMBED. MINIMUM 4 ANCHORS SPACED AT A MINIMUM OF 18" EACH WAY. # J: \ 2 0 2 4 b \ 2 0 2 4 - 0 0 6 7 . 1 1 - r e d _ b u l l _ e l e c t r a d a _ s a n t a _ a n a _ s t r u c t u r a l \ 1 0 - d e s i g n \ D r a w i n g s \ w o r k i n g d o c u m e n t s \ S H E E T S \ L A M I R A D A \ E L E C T R I C A L \ E V - 0 3 . d w g 2 0 2 6 - 0 2 - 0 9 Project Title: Drawing Title: RevisionDateNo. Date: Drawn: Checked: Job No: Scale: Drawing No: SHT:OF BURNS ENGINEERING, INC. | 310-439-5643 300 NORTH CONTINENTAL BLVD SUITE 540 EL SEGUNDO, CA 90245 3 RED BULL ELECTRADA STRUCTURAL DESIGN SANTA ANA 1900 EAST DEERE AVE, SANTA ANA, CA92705 ADDRESS: 1 06/24/2025 CD30 2 07/02/2025 CD90 3 07/15/2025 ISSUE FOR PERMIT 4 01/14/2026 PLAN CHECK COMMENTS STRUCTURAL SITE PLAN 2/9/2026 AS NOTED CS IB 2024.0067.11 SEV-03 EV - 0 3 . D W G 3 N 2 SEV-03 BOLLARD NTS 8" X 8" X 1/2" 3 SEV-03 EV PEDESTAL SPEC SHEET NTS 5/16 5. ANCHORS SHALL BE KWICK BOLT TZ2 MIN 1/2" DIAMETER WITH 3.25" EMBED. MINIMUM 4 ANCHORS DAVI D H I LLEY C97125 STATE OF CALIFORNIA L ICENSED PROFES S IONAL ENGINEER C I V I L YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs PREPARED BY: LOCATION MAP SCALE: NTS RED BULL - ELECTRADA EV CHARGING - SANTA ANA 1900 EAST DEERE AVE, SANTA ANA, CA 92705 NSCOPE OF WORK: THIS PROJECT INVOLVES THE INSTALLATION OF SIX (6) 48A, LEVEL 2 EV CHARGERS. THE DESIGN INCLUDES DISTRIBUTION FROM A NEW PANEL FED FROM AN EXISTING UTILITY SERVICE AND ASSOCIATED INFRASTRUCTURE TO SUPPORT THE INSTALLATION. SYSTEM OWNERS: ELECTRADA 231 W 12TH ST SUITE 600 CINCINNATI, OH 45202 (513) 632-0360 ELECTRICAL ENGINEER: MERI MARUTYAN BURNS ENGINEERING, INC. 300 NORTH CONTINENTAL BLVD SUITE 540 EL SEGUNDO, CA 90245 213-344-4699 AUTHORITY HAVING JURISDICTION: CITY OF SANTA ANA GENERAL COMPLIANCE - CA DESIGN AND PERFORMANCE OF COMPONENTS AND METHODS SPECIFIED HEREIN SHALL COMPLY WITH THE LATEST ADOPTED VERSIONS OF THE STATE OF CALIFORNIA CODES, AND THE LOCAL AUTHORITIES HAVING JURISDICTION INCLUDING BUT NOT LIMITED TO: ·TITLE 24 CALIFORNIA CODE OF REGULATIONS ·2021 IBC INTERNATIONAL BUILDING CODE ·2021 IECC INTERNATIONAL ENERGY CONSERVATION CODE ·2020 NFPA 70 NATIONAL ELECTRICAL CODE ·2022 NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE ·2018 NFPA 101 LIFE SAFETY CODE ·2020 NFPA 70E STANDARD FOR ELECTRICAL SAFETY IN THE WORKPLACE ·2020 NFPA 110 STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS ·2023 NESC NATIONAL ELECTRICAL SAFETY CODE ·2022 CEC CALIFORNIA ELECTRICAL CODE ·2022 BUILDING ENERGY EFFICIENCY STANDARDS ·2022 CBC CALIFORNIA BUILDING CODE PROPERTY DETAILS: ASSESSOR'S PARCEL NUMBER: 430-191-16 PROPERTY SIZE: 73,445.71 SQ. FT. BUILDING AREA: 22,022 SQ. FT. TYPE OF CONSTRUCTION PER C.B.C: TYPE III-B OCCUPANCY GROUP PER C.B.C: B AND S-1 NUMBER OF STORIES: 1 (1 STORY WAREHOUSE) SPRINKLERED: YES J: \ 2 0 2 4 b \ 2 0 2 4 - 0 0 6 7 . 1 1 - r e d _ b u l l _ e l e c t r a d a _ s a n t a _ a n a \ 1 0 - d e s i g n \ D r a w i n g s \ w o r k i n g d o c u m e n t s \ S H E E T S \ L A M I R A D A \ E L E C T R I C A L \ E V - 0 1 . d w g 2 0 2 6 - 0 1 - 1 4 Project Title: Drawing Title: RevisionDateNo. Date: Drawn: Checked: Job No: Scale: Drawing No: SHT:OF BURNS ENGINEERING, INC. | 310-439-5643 300 NORTH CONTINENTAL BLVD SUITE 540 EL SEGUNDO, CA 90245 RED BULL ELECTRADA EV CHARGING SANTA ANA 1 06/24/2025 CD30 ADDRESS: 1900 EAST DEERE AVE, SANTA ANA, CA 92705 ADDRESS: 10 2 07/02/2025 CD90 3 07/15/2025 ISSUE FOR PERMIT 4 11/03/2025 PLAN CHECK COMMENTS COVER SHEET 1/14/2026 AS NOTED CS IB 2024.0067.11 EV-01 EV - 0 1 . D W G 1 EV ACCESSIBILITY: THE INSTALLATION OF (6) EV CHARGER IS FOR PRIVATE FLEET VEHICLES IS EXEMPT FROM THE REQUIREMENTS OF 2022 CBC 11B-228.3.2 PURSUANT TO EXCEPTION 1. Sheet List Table Sheet Number Sheet Title Sheet Description 1 EV-01 COVER SHEET 2 EV-02 SITE PLAN 3 EV-03 EV SITE PLAN 4 EV-04 SINGLE LINE DIAGRAM 5 EV-05 PANEL SCHEDULE 6 EV-06 ELECTRICAL NOTES 7 EV-07 ELECTRICAL SPECIFICATIONS 8 EV-08 EQUIPMENT SPEC SHEET 9 EV-09 DETAILS 10 EV-10 EQUIPMENT SPEC SHEET 1 EV-02 SANTA ANA BUILDING PLAN N.T.S N J: \ 2 0 2 4 b \ 2 0 2 4 - 0 0 6 7 . 1 1 - r e d _ b u l l _ e l e c t r a d a _ s a n t a _ a n a \ 1 0 - d e s i g n \ D r a w i n g s \ w o r k i n g d o c u m e n t s \ S H E E T S \ L A M I R A D A \ E L E C T R I C A L \ E V - 0 2 . d w g 2 0 2 6 - 0 1 - 1 4 Project Title: Drawing Title: RevisionDateNo. Date: Drawn: Checked: Job No: Scale: Drawing No: SHT:OF BURNS ENGINEERING, INC. | 310-439-5643 300 NORTH CONTINENTAL BLVD SUITE 540 EL SEGUNDO, CA 90245 RED BULL ELECTRADA EV CHARGING SANTA ANA 1 06/24/2025 CD30 ADDRESS: 1900 EAST DEERE AVE, SANTA ANA, CA 92705 ADDRESS: 10 2 07/02/2025 CD90 3 07/15/2025 ISSUE FOR PERMIT 4 11/03/2025 PLAN CHECK COMMENTS SITE PLAN 1/14/2026 AS NOTED CS IB 2024.0067.11 EV-02 EV - 0 2 . D W G 2 226FT 318FT 200FT 19FT 20FT (E) LANDSCAPE PLANTER (E) LANDSCAPE PLANTER PROPERTY FENCE LINE 119FT 181FT 191FT 9FT NO PARKING HANDICAP PARKING 217FT 533.0907 24FT 26FT CENTERLINE E DEERE AVE STREET (E) DRIVEWAY NO SIDEWALK 309FT EXISTING BUILDING AREA OF WORK NO WORK TO BE DONE IN HASHED AREAS NO WORK TO BE DONE IN HASHED AREAS 23FT 30FT 190FT 14FT PEDESTRIAN WALKWAY 97FT 27FT 8FT 32FT (N) EVSE-1 EVDP-1 17, 19 EVDP-1 13, 15 EVDP-1 9, 11 EVDP-1 5, 7 EVDP-1 1, 3 (N) EVSE-2 (N) EVSE-3 (N) EVSE-4 (N) EVSE-5 EVDP-1 21, 23 (N) EVSE-6 (E) MAIN SECTION CH2-1 UNUSED SERVICE DISCONNECT GARAGE ENTRANCE/EXIT (N) T-EVDP-1 (N) EVDP-1 (N) MNB-1 M (N) EVDP-1 SUBMETER (E) UTILITY TRANSFORMER (N) 4" DIAMETER BOLLARD (E) COLUMN (TYP.) (E) FENCE (TYP.) (N) 4" DIAMETER BOLLARD EVDP-1 30 (E) RACKING TO REMAIN (E) RACKING TO REMAIN (E) FENCE (TYP.) PARKING SPACE IS 11' x 24' (TYP.) 2" YELLOW SUPERIOR MARK FLOOR MARKING TAPE (TYP.) (N) 4" DIAMETER BOLLARD EV PEDESTAL EV PEDESTAL (TYP. FOR EVSE-1 THROUGH EVSE-5) (E) COMM ROOM 2" YELLOW SUPERIOR MARK FLOOR MARKING TAPE (TYP.) (E) OFFICE (E) RACKING TO REMAIN (E) RACKING TO REMAIN (N) STORAGE CABINET (N) DS-T1 1 EV-03 SANTA ANA EV BUILDING PLAN 3/32" = 1'-0" GENERAL NOTES: 1.EVSE SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2.MAINTAIN NEC CLEARANCES AROUND EVSE AND ELECTRICAL EQUIPMENT. REMOVE AND OR RELOCATE EQUIPMENT AS REQUIRED. 3.SEE SHEET EV-04 FOR SINGLE LINE DIAGRAM AND FEEDER SCHEDULE. 4.FOR EV CHARGERS SEE DETAIL 2/EV-08 FOR 48A EVSE DATASHEET. 5.EVSE VOLTAGE DROP SHALL BE 3% MAXIMUM FROM PANEL TO EVSE. ELECTRICAL CONTRACTOR SHALL ADJUST CONDUIT AND WIRE SIZES AS REQUIRED TO MAINTAIN VOLTAGE DROP. 6.COORDINATE EVSE LOCATIONS WITH RESTRIPING PLAN. 7.ALL PENETRATIONS THROUGH CONCRETE STRUCTURAL FLOORING SHALL BE SCANNED WITH GROUND PENETRATING RADAR (GPR). SUBMIT FINDINGS TO ENGINEER FOR APPROVAL PRIOR TO PENETRATION. 8.THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, AND SITE CONDITIONS PRIOR TO THE START OF CONSTRUCTION AND NOTIFY THE ENGINEERING IMMEDIATELY OF ANY DISCREPANCIES OR INCONSISTENCIES. 9.FURNISH AND INSTALL STRIPPING FOR PARKING SPACES, UTILIZE SUPERIOR MARK FLOOR MARKING TAPE. COORDINATE EXACT DIMENSIONS AND LOCATIONS WITH RED BULL AND ELECTRADA. ELECTRICAL KEY NOTES: 1.MOUNT EVSE AND CABLE HOLSTER TO PEDESTAL. PEDESTAL HEIGHT 65". SEE DETAIL 1/EV-10. 2.PROVIDE 1" CONDUIT WITH (1) UNSHIELDED CAT6A CABLE BACK TO COMM ROOM. 3.CONTRACTOR SHALL PROVIDE BOLLARDS AS SHOWN FOR EACH COMPONENT BEING PROTECTED AS PER DETAIL 1/EV-09. SUBMIT DETAILS PRIOR TO INSTALLATION. 4.PROVIDE FOR DATA CONNECTION RUN BACK TO MNB. 5.EYEWASH STATION AND FORKLIFT CHARGER ARE CURRENTLY EXISTING IN THIS LOCATION, AND ARE BEING RELOCATED (LOCATION TO BE DETERMINED). # J: \ 2 0 2 4 b \ 2 0 2 4 - 0 0 6 7 . 1 1 - r e d _ b u l l _ e l e c t r a d a _ s a n t a _ a n a \ 1 0 - d e s i g n \ D r a w i n g s \ w o r k i n g d o c u m e n t s \ S H E E T S \ L A M I R A D A \ E L E C T R I C A L \ E V - 0 3 . d w g 2 0 2 6 - 0 1 - 1 4 Project Title: Drawing Title: RevisionDateNo. Date: Drawn: Checked: Job No: Scale: Drawing No: SHT:OF BURNS ENGINEERING, INC. | 310-439-5643 300 NORTH CONTINENTAL BLVD SUITE 540 EL SEGUNDO, CA 90245 10 RED BULL ELECTRADA EV CHARGING SANTA ANA 1900 EAST DEERE AVE, SANTA ANA, CA92705 ADDRESS: 1 06/24/2025 CD30 2 07/02/2025 CD90 3 07/15/2025 ISSUE FOR PERMIT 4 01/14/2026 PLAN CHECK COMMENTS EV SITE PLAN 1/14/2026 AS NOTED CS IB 2024.0067.11 EV-03 EV - 0 3 . D W G 3 N MUTILITY METER SPD EXISTING CH2-1, 3000A,480/277V, 3PH, 4W, NEMA 1 CUSTOMER SECTION SCE METER SECTION V349N-006608 3000AF 3000AT LSI N G UTILITY TRANSFORMER SCE (E) (E) (E) SUB PNL #1 400AF 400AT 3P 400AF 400AT 3P LOCKED 600AF 600AT 3P LOCKED 200AF 200AT 3P LIGHTS 200AF 200AT 3P EVSE-1 SINGLE PORT 9.98KW EVSE-2 SINGLE PORT 9.98KW EVSE-3 SINGLE PORT 9.98KW EVSE-4 SINGLE PORT 9.98KW EVSE-5 SINGLE PORT 9.98KW EVSE-6 SINGLE PORT 9.98KW 100AF 60AT 2P 100AF 60AT 2P 100AF 60AT 2P 100AF 60AT 2P 100AF 60AT 2P 100AF 60AT 2P NEW EVDP-1, 250A, 208/120V, 3PH, 4W, 65KAIC, NEMA 1 T-EVDP-1, 75KVA 480V:208/120V 3PH,4W 3 #2 CU - 3/4" EMT N G 250AF 250AT #2 CU 3 ELECTRICAL KEY NOTES: 1.PROVIDE INTEGRAL TYPE 2 200KA SPD WITH DISCONNECT INSTALLED BY MANUFACTURER. 2.CONTRACTOR TO UTILIZE EXISTING 400AF/400AT CIRCUIT BREAKER. 3.BOND TO BUILDING GROUNDING ELECTRODE CONDUCTOR (GEC) PER CEC 250.30(A)(4,5). 4.PROVIDE SUBMETER FOR EV DISTRIBUTION - ACCUENERGY ACUPANEL 9104X-IIW-MV-P3V3-WEB2, 400A, 480/277V, 3P, 3W. EXACT SPECIFICATIONS TO BE COORDINATED WITH ELECTRADA. 5.CIRCUIT BREAKERS SERVING EVSE EQUIPMENT SHALL BE LOCKABLE OPEN IN ACCORDANCE WITH NEC 625.43, TYPICAL. GENERAL NOTES: 1.COORDINATE EQUIPMENT AIC RATINGS WITH AVAILABLE UTILITY FAULT CURRENT. 2.TORQUE EVSE WIRING PER MANUFACTURER'S INSTRUCTIONS. # SPD 1 2 5 DS-T1 200AS 125AF 3P NEMA 1 M EVDP-1 SUBMETER NEMA 1 4 C-03 MNB-1 0.60KVA 100AF 30AT 1P C-04 C-01 C-02 C-01 C-01 40 FT. GROUND FLOOR ROOF MNB EVSE-1 (1) CAT6A - 3/4" C. TYP. TO EVSE (6) CAT6A - 1 1/4" C. (5) CAT6A - 1 1/4" C. EVSE-2 EVSE-3 EVSE-4 EVSE-5 EVSE-6 (4) CAT6A - 1 1/4" C. (3) CAT6A - 1" C. (2) CAT6A - 1" C. (1) CAT6A - 3/4" C. JUNCTION BOX TYP. EVSE POWER CIRCUITS RAN ABOVE LOW VOLTAGE EVDP-1 SUBMETER (1) CAT6A - 1" C. LOCKED 600AF 600AT 3P 1 EV-04 SINGLE LINE DIAGRAM NTS J: \ 2 0 2 4 b \ 2 0 2 4 - 0 0 6 7 . 1 1 - r e d _ b u l l _ e l e c t r a d a _ s a n t a _ a n a \ 1 0 - d e s i g n \ D r a w i n g s \ w o r k i n g d o c u m e n t s \ S H E E T S \ L A M I R A D A \ E L E C T R I C A L \ E V - 0 4 . d w g 2 0 2 6 - 0 1 - 1 4 Project Title: Drawing Title: RevisionDateNo. Date: Drawn: Checked: Job No: Scale: Drawing No: SHT:OF BURNS ENGINEERING, INC. | 310-439-5643 300 NORTH CONTINENTAL BLVD SUITE 540 EL SEGUNDO, CA 90245 10 RED BULL ELECTRADA EV CHARGING SANTA ANA 1900 EAST DEERE AVE, SANTA ANA, CA92705 ADDRESS: 1 06/24/2025 CD30 2 07/02/2025 CD90 3 07/15/2025 ISSUE FOR PERMIT 4 01/14/2026 PLAN CHECK COMMENTS SINGLE LINE DIAGRAM 1/14/2026 AS NOTED CS IB 2024.0067.11 EV-04 EV - 0 4 . D W G 4 FEEDER SCHEDULE NOMINAL VOLTAGE (V) TOTAL CURRENT (A) CONDUCTOR MATERIAL SETS CONDUCTORS CONDUCTOR SIZE GROUND SIZE INSULATION CONDUIT SIZE CONDUIT TYPE FARTHEST LENGTH (FT) VOLTAGE DROP C-01 480 97.5 COPPER 1 3 #1 #6 THHN 1-1/2"EMT 9 0.05% C-02 208 250.0 COPPER 1 4 250 #4 THHN 2-1/2"EMT 7 0.09% C-03 208 48.0 COPPER 1 2 #4 #8 THHN 1-1/4"EMT 175 2.45% C-04 208 30.0 COPPER 1 2 #10 #10 THHN 1/2"EMT 6 0.17% C-X 2 EV-04 LOW VOLTAGE RISER DIAGRAM NTS GENERAL NOTES: 1.SEE EV-04 FOR SINGLE LINE DIAGRAM AND FEEDER SCHEDULE. J: \ 2 0 2 4 b \ 2 0 2 4 - 0 0 6 7 . 1 1 - r e d _ b u l l _ e l e c t r a d a _ s a n t a _ a n a \ 1 0 - d e s i g n \ D r a w i n g s \ w o r k i n g d o c u m e n t s \ S H E E T S \ L A M I R A D A \ E L E C T R I C A L \ E V - 0 5 . d w g 2 0 2 6 - 0 1 - 1 4 Project Title: Drawing Title: RevisionDateNo. Date: Drawn: Checked: Job No: Scale: Drawing No: SHT:OF BURNS ENGINEERING, INC. | 310-439-5643 300 NORTH CONTINENTAL BLVD SUITE 540 EL SEGUNDO, CA 90245 10 RED BULL ELECTRADA EV CHARGING SANTA ANA 1900 EAST DEERE AVE, SANTA ANA, CA92705 ADDRESS: 1 06/24/2025 CD30 2 07/02/2025 CD90 3 07/15/2025 ISSUE FOR PERMIT 4 01/14/2026 PLAN CHECK COMMENTS PANEL SCHEDULE 1/14/2026 AS NOTED CS IB 2024.0067.11 EV-05 EV - 0 5 . D W G 5 SWITCHBOARD: EVDP-1 VOLTAGE: 208Y/120V, 3Φ, 4W PHASE BUS RATING: 250A MOUNTING: SURFACE MAIN TYPE: MCB NEUTRAL BUS RATING: 250A ENCLOSURE RATING: NEMA 1 MAIN RATING: 250A GROUND BUS RATING: 250A LOCATION: AIC RATING: 65kA SUB-FEED LUGS: NO FEED-THRU LUGS: NO CKT NO. BREAKER WIRE DESCRIPTION CONNECTED KVA PER PHASE DESCRIPTION WIRE BREAKER CKT NO. POLE AMPS PH NEUT GND A A B B C C PH NEUT GND POLE AMPS 1 2 60 SEE SINGLE LINE EVSE-1 5.0 -SPACE ---1 20 2 3 ------5.0 -SPACE ---1 20 4 5 2 60 SEE SINGLE LINE EVSE-2 5.0 -SPACE ---1 20 6 7 ------5.0 -SPACE ---1 20 8 9 2 60 SEE SINGLE LINE EVSE-3 5.0 -SPACE ---1 20 10 11 ------5.0 -SPACE ---1 20 12 13 2 60 SEE SINGLE LINE EVSE-4 5.0 -SPACE ---1 20 14 15 ------5.0 -SPACE ---1 20 16 17 2 60 SEE SINGLE LINE EVSE-5 5.0 -SPACE ---1 20 18 19 ------5.0 -SPACE ---1 20 20 21 2 60 SEE SINGLE LINE EVSE-6 5.0 -SPACE ---1 20 22 23 ------5.0 -SPACE ---1 20 24 25 1 20 ---SPACE -0.2 MNB-1 SEE SINGLE LINE 1 30 26 27 1 20 ---SPACE --SPACE ---1 20 28 29 1 20 -SPACE --SERVICE RECEPTACLE #12 #12 #12 1 20 30 31 1 20 ---SPACE --SPACE ---1 20 32 33 1 20 -SPACE --SPACE ---1 20 34 35 1 20 ---SPACE --SPACE ---1 20 36 37 1 20 -SPACE --SPACE ---1 20 38 39 1 20 ---SPACE --SPACE ---1 20 40 41 1 20 ---SPACE --SPACE ---1 20 42 TOTAL CONNECTED KVA PER PHASE:20.1 20.0 20.0 TOTAL CONNECTED KVA:60.1 TOTAL ESTIMATED DEMAND CURRENT PER PHASE:167.9 166.4 166.4 TOTAL CONNECTED CURRENT:166.8 TOTAL ESTIMATED DEMAND KVA:75.6 TOTAL ESTIMATED DEMAND CURRENT:209.9 LOAD CALCULATIONS - MAIN SWITCHGEAR EQUIPMENT PEAK DEMAND (kW)CURRENT (A) METER# V349N-006608 26kW (BETWEEN 02/24-04/25)31A NEW EVDP-1 DEMAND 75.7kW 209.9 A TOTAL DEMAND 101.7kW 240.0 A 3000A MAIN SWITCHGEAR CAPACITY 2493.0 kW 3000 A LOAD CALCULATION CONFIRMS THAT THE EXISTING 3000A METER SECTION HAS SUFFICIENT CAPACITY TO ACCOMMODATE THE NEW LOAD SINGLE LINE DIAGRAM LEGEND: CONDUIT TURNING DOWN CONDUIT TURNING UP ELECTRICAL LEGEND: 20A, 125V GFCI DUPLEX RECEPTACLE NEW WORK KEY NOTE# ANNOTATION 100 AF / 60 AT 100/90 208/120V 480V 500KVAY GROUND CONNECTION FUSED SWITCH <SWITCH AMPS>/<FUSE AMPS>/<POLES> POWER TRANSFORMER VOLTAGES, WINDINGS AND SIZE AS INDICATED UNFUSED SWITCH <SWITCH AMPS>/<POLES> CIRCUIT BREAKER - MOLDED CASE TYPE <AMP FRAME>/<AMP TRIP> CIRCUIT BREAKER - DRAW-OUT TYPE <FRAME AMPS>/<TRIP AMPS> CURRENT TRANSFORMER NUMBER AND RATIO AS INDICATED XXX/5 3 TRANSFORMER UNFUSED DISCONNECT SWITCH, MOUNT 48" AFF <SWITCH AMPS>/<POLES>, VOLTAGE RATING AS REQUIRED FUSED DISCONNECT SWITCH <SWITCH AMPS>/<FUSE AMPS>/<POLES>, VOLTAGE RATING AS REQUIRED SURFACE MOUNTED PANELBOARD MOUNT 48" AFF T HANDHOLEH FEEDER TAG POTENTIAL TRANSFORMER MV CIRCUIT BREAKER SURGE ARRESTER SPD SURGE PROTECTIVE DEVICE EM#ELECTRICAL MANHOLE G GROUND BUS N NEUTRAL BUS Y DELTA GROUNDED WYE GROUND LEVEL ELECTRICAL CONDUIT COMMUNICATION CONDUIT ELECTRICAL ENCLOSURE VOLTAGE CLASS DUTY CLASS MCOV UNDERGROUND CONDUIT DUCTBANK GROUND ROD WITH TEST WELL G ELECTRICAL CONNECTION BEFORE YOU DIG CALL TOLL FREE IN CALIFORNIA 811 TWO DAYS BEFORE YOU DIG UNDERGROUND ELECTRICAL CONDUIT ELECTRICAL ABBREVIATIONS: LIGHT FIXTURE. SEE LIGHTING FIXTURE SCHEDULE. A = DESIGNATIONA A, AMP AMPERE AERS ARC ENERGY REDUCTION SYSTEM AF AMP FRAME AFF ABOVE FINISHED FLOOR AG ABOVE GRADE AIC AMPERE INTERRUPTING CAPACITY APPROX APPROXIMATE(LY) AT AMP TRIP AL ALUMINIUM AWG AMERICAN WIRE GAUGE BG BELOW GRADE BKR BREAKER C CONDUIT CB CIRCUIT BREAKER CKT CIRCUIT CMS CABLE MANAGEMENT SYSTEM CU COPPER CT CURRENT TRANSFORMER DAS DATA ACQUISITION SYSTEM DS DISCONNECT SWITCH DWG DRAWING (E)EXISTING EC ELECTRICAL CONTRACTOR ELEC ELECTRICAL EMT ELECTRICAL METALLIC TUBING EM EMERGENCY ENC ENCLOSURE, ENCLOSED (ER)EXISTING TO BE RELOCATED EV ELECTRIC VEHICLE EVCS ELECTRIC VEHICLE CHARGING STATION EVDP ELECTRIC VEHICLE DISTRIBUTION PANEL EVSE ELECTRIC VEHICLE SUPPLY EQUIPMENT F FUSE FMC FLEXIBLE METAL CONDUIT FT FEET, FOOT G, GND GROUND OR GROUNDING GA GALVANIZED GFCI GROUND FAULT CIRCUIT INTERRUPTER GFP GROUND FAULT PROTECTION IN INCHES J, JB JUNCTION BOX KCMIL THOUSAND CIRCULAR MILS KV KILOVOLT KVA KILOVOLT-AMPERE KW KILOWATT LSIG LONG TIME, SHORT TIME, INSTANTANEOUS, GFP MAX MAXIMUM MBJ MAIN BONDING JUMPER MC METAL CLAD MCB MAIN CIRCUIT BREAKER MDB MINI-DAUGHTER BOX MDP MAIN DISTRIBUTION PANEL MFR MANUFACTURER MIN MINIMUM MLO MAIN LUGS ONLY MNB MINI-NETWORK BOX MOV METAL-OXIDE VARISTOR MTG MOUNTING N, NEUT NEUTRAL (N)NEW NEC NATIONAL ELECTRICAL CODE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NGOM NET GENERATION OUTPUT METER NTS NOT TO SCALE P POLE PG&E PACIFIC GAS & ELECTRIC PH PHASE PNL PANEL OR PANELBOARD PT POTENTIAL TRANSFORMER PVC POLYVINYL CHLORIDE PWR POWER (R)REMOVE (RE)RELOCATED EXISTING EQUIPMENT RELT REDUCED ENERGY LET THROUGH REQ'D REQUIRED RGS RIGID GALVANIZED STEEL RMC RIGID METAL CONDUIT SCE SOUTHERN CALIFORNIA EDISON SP SPARE SPD SURGE PROTECTIVE DEVICE ST SHUNT TRIP STC STANDARD TEST CONDITIONS SW SWITCH SWBD SWITCHBOARD SWGR SWITCHGEAR T TRANSFORMER TB TERMINAL BLOCK TBD TO BE DETERMINED TYP TYPICAL UON UNLESS OTHERWISE NOTED UL UNDERWRITERS LABORATORIES V VOLT W WIRE, WATT W/WITH WP WEATHERPROOF (3R RATING, MINIMUM) WS WEATHER STATION XFMR TRANSFORMER XHHW XLPE HIGH HEAT-RESISTANT WATER-RESISTANT XLPE CROSS-LINKED POLYETHYLENE %PERCENT Δ DELTA Y WYE UNDERGROUND EXISTING CONDUIT UNDERGROUND WATER LINE FENCE LINE DATA CONNECTION - ONE (1) CAT6A IN 3/4" EMT TO NEAREST MDB OR MNB OVERHEAD ELECTRICAL CONDUIT GENERAL NOTES 1.THESE DRAWINGS ARE PRESENTED TO THE ELECTRICAL CONTRACTOR WITH THE UNDERSTANDING THAT THE ELECTRICAL CONTRACTOR IS LICENSED AND EXPERIENCED TO PROVIDE SERVICES AND IS COMPETENT IN THE PREPARATION OF CONTRACT BID PRICES ON THE BASIS OF INFORMATION SUCH AS IS CONTAINED IN THESE DOCUMENTS. IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO CALL FOR FINISHED WORK, TESTED AND READY FOR OPERATION AND IN COMPLETE CONFORMANCE WITH ALL APPLICABLE CODES, RULES, AND REGULATIONS. MINOR ITEMS NOT USUALLY SHOWN OR SPECIFIED, BUT MANIFESTLY NECESSARY FOR THE PROPER INSTALLATION AND OPERATION OF THE VARIOUS SYSTEMS, SHALL BE INCLUDED IN THE WORK AND IN THE PROPOSAL THE SAME AS IF SPECIFIED OR SHOWN ON THE DRAWINGS. IF ANY DEPARTURES FROM THE DRAWINGS ARE DEEMED NECESSARY, DETAILS OF SUCH DEPARTURES AND THE REASONS THEREFORE SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL. NO DEPARTURES SHALL BE MADE WITHOUT PRIOR APPROVAL OF THE ENGINEER AND OWNER. 2.DEFINITION: UNLESS OTHERWISE NOTED, ALL WORK SPECIFIED HEREIN OR NOTED ON DRAWINGS, SHALL BE BY THE ELECTRICAL CONTRACTOR. ALL REFERENCES TO "CONTRACTOR" OR "THIS CONTRACTOR" ON DRAWINGS OR SPECIFICATIONS ARE ADDRESSED TO THE ELECTRICAL CONTRACTOR. THE TERM "PROVIDE" WHENEVER ENCOUNTERED ON DRAWINGS OR IN THESE SPECIFICATIONS, SHALL MEAN "FURNISH AND INSTALL." 3.THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL DIMENSIONS IN THE FIELD, AND SHALL ADVISE THE ENGINEER AND THE OWNER OF ANY DISCREPANCIES BEFORE PERFORMING THE WORK. 4.DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND WORK. CONDUIT ROUTING IS SHOWN DIAGRAMMATICALLY AND DOES NOT SHOW ALL BENDS, OFFSETS, DROPS AND RISES OF RUNS. THE CONTRACTOR SHALL ALLOW FOR ROUTING OF CONDUIT TO AVOID OBSTRUCTIONS. COORDINATE WITH OTHER TRADES, AS REQUIRED. THE EXACT LOCATIONS OF DEVICES AND EQUIPMENT ARE SUBJECT TO THE APPROVAL OF THE OWNER. 5.CUT CONDUIT ENDS SQUARE. REAM SMOOTH. PAINT MALE THREAD OF FIELD THREADED RACEWAYS WITH GRAPHITE BASE PIPE COMPOUND. DRAW UP TIGHT WITH RACEWAY COUPLING. 6.LEAVE WIRES WITH SUFFICIENT SLACK TO PERMIT MAKING FINAL CONNECTIONS. RACEWAYS OVER 10' LONG IN WHICH WIRING IS NOT INSTALLED: FURNISH NYLON PULL STRING. FOR ANY RACEWAY OVER 25' PROVIDE PULL STRING WITH CONDUIT MEASURING TAPE AND INDICATE DESIGNATION OF THE RACEWAY ON EACH END. 7.COVERS OF JUNCTION AND PULLBOXES SHALL BE ACCESSIBLE. 8.PROVIDE PULLBOXES WHERE INDICATED, REQUIRED BY CODE AND WHEREVER NECESSARY TO FACILITATE PULLING OF WIRE. 9.PULL NO THERMOPLASTIC WIRES AT AMBIENT TEMPERATURES LOWER THAN 32°F (0°C). PROVIDE CABLE SUPPORTS FOR WIRE IN RISER CONDUITS AS REQUIRED BY CODE. 10.THE CONTRACTOR IS RESPONSIBLE FOR REPORTING INCONSISTENCIES TO THE ENGINEER IN FORM OF "RFI" REQUEST FOR INFORMATION BEFORE ANY INACCURATE WORK IS EXECUTED. 11.IN THE EVENT OF CONFLICT BETWEEN THE CONTRACT DRAWINGS AND THE SPECIFICATIONS, THE MOST RIGID REQUIREMENTS SHALL GOVERN. 12.CONTRACTOR/INSTALLER SHALL PROVIDE ALL MATERIALS, LABOR, EQUIPMENT AND SERVICES AND PERFORM ALL OPERATIONS IN CONNECTION WITH THE ELECTRICAL WORK. 13.CONTRACTOR/INSTALLER SHALL COMPLY WITH THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION, INCLUDING THE NATIONAL ELECTRICAL CODE (NEC), NEMA, ANSI, AND IEEE STANDARDS THROUGHOUT THE PROJECT. ALL WORK SHALL COMPLY WITH ALL LOCAL, STATE AND FEDERAL CODES AND THE REQUIREMENTS OF ANY OTHER AUTHORITIES HAVING JURISDICTION. CONTRACTOR SHALL SUBMIT DOCUMENTATION THAT ALL NEW WORK PROVIDED UNDER THIS PROJECT WAS INSPECTED AND APPROVED BY THE AHJ TO BE IN COMPLIANCE WITH THE LATEST APPROVED VERSION OF THE NEC (NFPA 70). 14.THE CONTRACTOR/INSTALLER SHALL VERIFY ALL EXISTING INFORMATION SHOWN (DIMENSIONS, OBSTRUCTIONS, ETC ) AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO INSTALLATION. 15.CONTRACTOR/INSTALLER SHALL BE RESPONSIBLE FOR MAINTAINING A RECORD SET OF INSTALLATION PRINTS. THE CONTRACTOR SHALL NEATLY AND CLEARLY RECORD ALL DEVIATIONS FROM THE CONTRACT DOCUMENTS. AT THE COMPLETION OF WORK, THE CONTRACTOR SHALL RETURN MARKED PRINTS WITH INFORMATION MAINTAINED DURING CONSTRUCTION TO THE ENGINEER. 16.CONTRACTOR/INSTALLER SHALL RETAIN ALL TESTING REPORTS PERFORMED AND PROVIDE TO OWNER AT COMPLETION OF WORK 17.CONTRACTOR/INSTALLER SHALL AT THE COMPLETION OF THE WORK, SECURE CERTIFICATES OF APPROVAL FROM THE VARIOUS AUTHORITIES HAVING JURISDICTION AND DELIVER TO OWNER. 18.EXISTING EQUIPMENT, BUILDING AREA, OR SURFACES DAMAGED SHALL BE RESTORED TO ITS ORIGINAL CONDITION OR REPLACED. 19.THE CONTRACTOR SHALL REMOVE, RELOCATE, REINSTALL, REROUTE, EXTEND, AND/OR ABANDON ALL EXISTING ELECTRICAL EQUIPMENT WHICH INTERFERES WITH THE NEW ELECTRICAL LAYOUTS. ALL SYSTEMS WHICH ARE NO LONGER REQUIRED TO FUNCTION SHALL BE DE-ENERGIZED AND DISCONNECTED AT THE SOURCE OF POWER SUPPLY. 20.INSTALL NEW WORK AND CONNECT TO EXISTING WORK WITH MINIMUM INTERFERENCE TO EXISTING FACILITIES. TEMPORARY SHUTDOWNS OF EXISTING SERVICES SHALL BE PERFORMED AT NO ADDITIONAL CHARGES, AT TIMES NOT TO INTERFERE WITH NORMAL OPERATION OF EXISTING FACILITIES AND ONLY WITH WRITTEN CONSENT OF OWNER. NOTIFICATION MUST BE GIVEN AT LEAST 7 DAYS PRIOR TO SHUT DOWN. ALARM AND EMERGENCY SYSTEMS SHALL NOT BE INTERRUPTED. MAINTAIN CONTINUOUS OPERATION OF EXISTING FACILITIES AS REQUIRED WITH NECESSARY TEMPORARY CONNECTIONS BETWEEN NEW AND EXISTING WORK. CONNECT NEW WORK TO EXISTING WORK IN NEAT AND ACCEPTABLE MANNER. RESTORE EXISTING DISTURBED WORK TO ORIGINAL CONDITION, INCLUDING MAINTENANCE OF WIRING CONTINUITY AS REQUIRED. 21.ALL EXISTING MATERIAL AND EQUIPMENT IN USABLE CONDITION, WHICH IS TO BE REMOVED UNDER THIS CONTRACT, SHALL REMAIN THE PROPERTY OF THE OWNER OR SHALL BE DISPOSED OF IN A LEGAL MANNER BY THE ELECTRICAL CONTRACTOR, AS DIRECTED BY THE OWNER. ITEMS OF SALVAGE SHALL BE CAREFULLY REMOVED AND STORED AT LOCATIONS DIRECTED BY THE OWNER. 22.ARRANGE TO WORK CONTINUOUSLY, INCLUDING OVERTIME, IF REQUIRED, TO ASSURE THAT SYSTEMS WILL BE SHUT DOWN ONLY DURING THE TIME ACTUALLY REQUIRED TO MAKE THE NECESSARY CONNECTIONS TO THE EXISTING SYSTEMS. 23.WHERE WIRING IS OVERSIZED TO ACCOMMODATE VOLTAGE DROP OR OTHER FACTORS, CONTRACTOR SHALL SPLICE DOWN TO LARGEST ACCEPTABLE CONDUCTOR SIZE THE TERMINATION ALLOWS. PROVIDE JUNCTION BOXES AS REQUIRED. SPLICE SHALL BE AS CLOSE AS PRACTICABLE TO FINAL TERMINATION. 24.CONTRACTOR SHALL COORDINATE INSTALLATION OF NEW UNDERGROUND WORK WITH EXISTING SUBSURFACE UTILITIES AND OBSTRUCTIONS. REROUTE AND OR RELOCATE EQUIPMENT AS REQUIRED. 25.ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED, OR CERTIFIED BY A NATIONALLY RECOGNIZED TESTING LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION. 26.THE MAXIMUM COMBINED VOLTAGE DROP ON BOTH INSTALLED FEEDER CONDUCTORS AND BRANCH CIRCUIT CONDUCTORS TO THE FARTHEST CONNECTED LOAD OR OUTLET SHALL NOT EXCEED 5 PERCENT. 27.LINEWEIGHTS: LIGHT LINEWEIGHT INDICATES EXISTING WORK OR WORK BY OTHERS. HEAVY DASHED LINEWEIGHT INDICATES EXISTING TO BE REMOVED OR DEMOLISHED. HEAVY LINEWEIGHT INDICATES NEW WORK. 28.ALL ELECTRICAL WORK SHALL BE DESIGNED PER 2022 CALIFORNIA ELECTRICAL CODE, 2020 NATIONAL ELECTRICAL CODE, AND 2022 BUILDING ENERGY EFFICIENCY STANDARDS. 100AS/3P 100AS/100AF/3P 30AS/3P 100AS/60AF/3P COMMUNICATIONS CABLE LABELING: EQUIPMENT TO BE LABELED IN ORDER OF PATHWAY FROM INTERNET SERVICE PROVIDER (ISP) TOWARD ELECTRIC VEHICLE (EV) CHARGER. ELECTRADA TO PROVIDE NETWORK DIAGRAM SHOWING HOW EQUIPMENT WILL BE CONNECTED. LABEL SCHEME WILL FOLLOW THE FORMAT OF <NAME OF EQUIPMENT><PORT OF CONNECTION IN SWITCH> - <NAME OF EQUIPMENT DOWNSTREAM><PORT CONNECTION NUMBER OR EVSE # PER EV SITE PLAN>. TEXT TO BE ONE LINE PER LABEL. BOTH SIDES OF CABLE TO BE LABELED THE SAME. USE BROTHER P-TOUCH CABLE, BRADY M210 LABEL MAKER, OR SIMILAR. COMMUNICATIONS CABLE TESTING: ALL CHARGERS TO BE TESTED FOR CONTINUITY AND CORRECT PAIRS USING A KLEIN TOOLS LAN EXPLORER DATA CABLE TESTER WITH REMOTE OR SIMILAR. ALL TEST RESULTS TO BE DOCUMENTED WITH ONE PHOTO PER TESTED CABLE, SHOWING THE CABLE CONNECTED TO THE TESTER, WITH LABEL CLEARLY VISIBLE AND THE SCREEN INDICATING A “PASS” RESULT. RESULTS TO BE COMPILED BY ELECTRADA DURING CLOSEOUT PROCESS AND ARE MANDATORY FOR PROJECT COMPLETION. J: \ 2 0 2 4 b \ 2 0 2 4 - 0 0 6 7 . 1 1 - r e d _ b u l l _ e l e c t r a d a _ s a n t a _ a n a \ 1 0 - d e s i g n \ D r a w i n g s \ w o r k i n g d o c u m e n t s \ S H E E T S \ L A M I R A D A \ E L E C T R I C A L \ E V - 0 6 . d w g 2 0 2 6 - 0 1 - 1 4 Project Title: Drawing Title: RevisionDateNo. Date: Drawn: Checked: Job No: Scale: Drawing No: SHT:OF BURNS ENGINEERING, INC. | 310-439-5643 300 NORTH CONTINENTAL BLVD SUITE 540 EL SEGUNDO, CA 90245 10 RED BULL ELECTRADA EV CHARGING SANTA ANA 1900 EAST DEERE AVE, SANTA ANA, CA92705 ADDRESS: 1 06/24/2025 CD30 2 07/02/2025 CD90 3 07/15/2025 ISSUE FOR PERMIT 4 01/14/2026 PLAN CHECK COMMENTS ELECTRICAL NOTES 1/14/2026 AS NOTED CS IB 2024.0067.11 EV-06 EV - 0 6 . D W G 6 ELECTRICAL SPECIFICATIONS 1.SCOPE OF WORK: 1.1.SCOPE OF WORK SHALL CONSIST OF PROVIDING LABOR, MATERIALS, EQUIPMENT, SERVICES AND FEES NECESSARY FOR COMPLETE AND SAFE INSTALLATION IN CONFORMITY WITH THE NATIONAL ELECTRICAL CODE , AND ALL OTHER APPLICABLE INDUSTRY, NATIONAL AND LOCAL CODES AND AUTHORITIES HAVING JURISDICTION, AS INDICATED ON DRAWINGS AND HEREIN SPECIFIED. 1.2.ALL DRAWINGS, PLANS, DETAILS, SPECIFICATIONS AND SPECIFICATION ADDENDA ARE MADE PART OF THIS CONTRACT AND SHALL APPLY TO ALL WORK UNDER THE CONTRACT UNLESS OTHERWISE AMENDED, MODIFIED, SUPPLEMENTED OR SPECIFIED HEREIN. 1.3.THE CONTRACTOR SHALL FURNISH A WRITTEN WARRANTY LETTER TO REPLACE OR REPAIR PROMPTLY AND ASSUME RESPONSIBILITY FOR ALL EXPENSES INCURRED, FOR ANY WORKMANSHIP AND EQUIPMENT IN WHICH DEFECTS DEVELOP WITHIN ONE YEAR FROM THE DATE OF FINAL CERTIFICATE FOR PAYMENT AND/OR FROM DATE OR ACTUAL USE OF EQUIPMENT OR OCCUPANCY OF SPACES BY OWNER, INCLUDED UNDER THE VARIOUS PARTS OF THE WORK, WHICHEVER DATE IS EARLIER. THIS WORK SHALL BE DONE AS DIRECTED BY THE OWNER. THIS WARRANTY SHALL ALSO PROVIDE THAT WHERE DEFECTS OCCUR, THE CONTRACTOR WILL ASSUME RESPONSIBILITY FOR ALL EXPENSES INCURRED IN REPAIRING AND REPLACING WORK OF OTHER TRADES AFFECTED BY DEFECTS, REPAIRS OR REPLACEMENTS IN EQUIPMENT SUPPLIED BY THE CONTRACTOR. THE WARRANTY LETTER IS TO BE COORDINATED WITH THE TERMS IN THE ELECTRADA MASTER SERVICE AGREEMENT (MSA) BETWEEN ELECTRADA AND THE CONTRACTOR. 1.4.THE CONTRACTOR SHALL GIVE NECESSARY NOTICE, FILE DRAWINGS AND SPECIFICATIONS WITH ALL DEPARTMENTS HAVING JURISDICTION, OBTAIN PERMITS OR LICENSES NECESSARY TO CARRY OUT THIS WORK AND PAY ALL FEES THEREFORE. THE CONTRACTOR SHALL ARRANGE FOR INSPECTION AND TESTS OF ANY OR ALL PARTS OF THE WORK IF SO REQUIRED BY AUTHORITIES AND PAY ALL CHARGES FOR THE SAME. THE CONTRACTOR SHALL PAY ALL COSTS FOR, AND FURNISH TO THE OWNER BEFORE FINAL BILLING, ALL CERTIFICATES NECESSARY AS EVIDENCE THAT THE WORK INSTALLED CONFORMS WITH ALL REGULATIONS WHERE THEY APPLY TO THIS WORK. 2.SHOP DRAWINGS 2.1.PRIOR TO THE INSTALLATION OF ANY WORK AND PROCUREMENT OF EQUIPMENT, CONTRACTOR SHALL PROVIDE COMPLETE SETS OF COORDINATED SHOP DRAWINGS OF ALL NEW AND EXISTING EQUIPMENT, INDICATING CAPACITY, DIMENSIONS AND SEQUENCE OF OPERATION FOR WRITTEN APPROVAL BY THE ENGINEER. 2.2.INDICATE ON EACH SHOP DRAWINGS SUBMITTED: 2.2.1.PROJECT NAME AND LOCATION 2.2.2.NAME OF ENGINEER 2.2.3.ITEM IDENTIFICATION 2.2.4.APPROVAL STAMP OF PRIME CONTRACTOR 3.AS-BUILT DRAWINGS AND EQUIPMENT OPERATIONAL INSTRUCTIONS 3.1.UPON COMPLETION AND ACCEPTANCE OF WORK, CONTRACTOR SHALL FURNISH WRITTEN INSTRUCTIONS AND EQUIPMENT MANUALS AND DEMONSTRATE TO THE OWNER THE PROPER OPERATION AND MAINTENANCE OF ALL EQUIPMENT AND APPARATUS FURNISHED UNDER THIS CONTRACT. 3.2.THESE INSTRUCTIONS SHALL BE TYPED ON 8-1/2 IN. X 11 IN. PAPER AND BOUND IN THREE RING BINDERS WITH CLEAR ACETATE COVERS. CONTRACTOR SHALL GIVE THREE COPIES OF THE INSTRUCTIONS TO THE OWNER AND ONE COPY TO THE ENGINEER. PROVIDE PDF ELECTRONIC COPY OF ALL PAPER INSTRUCTIONS. 3.3.THE INSTRUCTION BOOKLET SHALL BEAR THE NAME, ADDRESS AND TELEPHONE NUMBER OF THE PROJECT AND ENGINEER. 3.4.REPRODUCIBLE "AS-BUILT" DRAWINGS SHALL BE PROVIDED IN FULL SIZE HARD COPY AND ON ELECTRONIC COPY ON A PORTABLE DRIVE (AUTOCAD 2020 OR LATER) INDICATING THE AS INSTALLED CONDITIONS OF THE WORK. "AS-BUILT" DRAWINGS SHALL BE PROVIDED TO THE OWNER AFTER COMPLETION OF THE INSTALLATION. 4.GENERAL PROVISIONS FOR ELECTRICAL WORK: 4.1.SPECIFICATIONS ARE OF SIMPLIFIED FORM AND INCLUDE INCOMPLETE SENTENCES. WORDS OR PHRASES SUCH AS "THE CONTRACTOR SHALL," "SHALL BE," "FURNISH," "PROVIDE," "A," "THE," AND "ALL" HAVE BEEN OMITTED FOR BREVITY. 4.2.DEFINITIONS: 4.2.1."PROVIDE": TO SUPPLY, INSTALL AND CONNECT UP COMPLETE AND READY FOR SAFE AND REGULAR OPERATION THE PARTICULAR WORK REFERRED TO UNLESS SPECIFICALLY OTHERWISE NOTED. 4.3.GENERAL 4.3.1.THE DRAWINGS SHOW THE APPROXIMATE LOCATION OF ALL APPARATUS. THE EXACT LOCATIONS OF WHICH ARE SUBJECT TO THE APPROVAL OF THE OWNER WHO RESERVES THE RIGHT TO MAKE ANY REASONABLE CHANGES IN THE LOCATION WITHOUT EXTRA COST. WHILE THE GENERAL RUN OF CONDUIT AND CABLES MAY BE INDICATED ON THE DRAWINGS, IT IS NOT INTENDED THAT THE EXACT ROUTING OR LOCATIONS OF CONDUIT & CABLES BE DETERMINED THEREFROM. 4.3.2.THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED BENDS, OFFSETS, PULL BOXES AND CLEARING OBSTRUCTIONS IT SHALL BE RESPONSIBILITY OF THE CONTRACTOR TO CONFORM TO THE STRUCTURE, MAINTAIN HEADROOM AND KEEP OPENINGS AND PASSAGEWAYS CLEAR 4.3.3.THE CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE WITH ALL TRADES 4.3.4.THE CONTRACTOR SHALL BE RESPONSIBLE FOR CLEAN-UP AND REMOVAL FROM THE SITE OF RESULTING DEBRIS. 4.4.TEMPORARY LIGHT AND POWER: PROVIDE TEMPORARY LIGHT AND POWER SYSTEMS AT EARLIEST POSSIBLE DATE WITHIN THE CONSTRUCTION AREAS FOR THE REQUIREMENTS OF ALL TRADES AS HEREIN DESCRIBED. EXTEND SYSTEMS TO NEW CONSTRUCTION AS SOON AS PHYSICALLY POSSIBLE. MAINTAIN SYSTEM DURING WORKING HOURS OF ALL TRADES. PROVIDE ALL REQUIRED MAINTENANCE, INCLUDING LAMPS AND SOCKETS. 4.5.UL CERTIFICATION SHALL BE PROVIDED TO EQUIPMENT IN CASE OF FIELD MODIFICATIONS. 4.6.QUALITY ASSURANCE 4.6.1.QUALITY AND GAUGE OF MATERIALS: NEW, BEST OF THEIR RESPECTIVE KINDS, FREE FROM DEFECTS AND LISTED BY UNDERWRITERS LABORATORIES, INC., OR OTHER NATIONALLY APPROVED TESTING AGENCY AND BEARING THEIR LABEL. MATERIALS AND EQUIPMENT OF SIMILAR APPLICATION SHALL BE OF SAME MANUFACTURER, EXCEPT AS NOTED. 4.7.MATERIALS 4.7.1.NAMEPLATES: PROVIDE BLACK LAMICOID SHEET WITH 3/4 IN. WHITE LETTERING, FASTENED WITH EPOXY CEMENT FOR EACH DISCONNECT SWITCH, CIRCUIT BREAKER, PANEL, CABINET, ENCLOSURE, AND THE LIKE. NAMEPLATES SHALL DESCRIBE THE NAME AND NUMBER OF EACH COMPONENT. 4.7.2.CABLE TAGS: TAG EACH CONDUCTOR PASSING THROUGH SPLICE OR PULLBOX WITH A WHITE LINEN TAG, INDICATING POINT OF ORIGIN AND TERMINATION OF THE CIRCUIT. 5.GROUNDING 5.1.ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES SHALL BE LISTED AND LABELED UNDER UL 467 AS DEFINED IN NFPA 70, ARTICLE 100, BY A TESTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, AND MARKED FOR INTENDED USE. 5.2.GROUNDING CONDUCTORS 5.2.1.FOR INSULATED CONDUCTORS, COMPLY WITH PARAGRAPH "CONDUCTORS AND CABLES." 5.2.2.MATERIAL: COPPER. 5.2.3.EQUIPMENT GROUNDING CONDUCTORS: INSULATED WITH GREEN-COLORED INSULATION. 5.2.4.GROUNDING ELECTRODE CONDUCTORS: STRANDED CABLE. 5.3.GROUNDING CONNECTOR PRODUCTS 5.3.1.COMPLY WITH IEEE 837 AND UL 467; LISTED FOR USE FOR SPECIFIC TYPES, SIZES, AND COMBINATIONS OF CONDUCTORS AND CONNECTED ITEMS. 5.3.2.CONNECTORS: BOLTED-PRESSURE-TYPE CONNECTORS SHALL BE PROVIDED FOR ONLY CONDUCTORS #10 AND SMALLER. ALL OTHER CONNECTORS SHALL BE COMPRESSION TYPE. 5.4.GROUNDING EXECUTION 5.4.1.IN ALL RACEWAYS, USE INSULATED EQUIPMENT GROUNDING CONDUCTORS. 5.4.2.EXOTHERMIC-WELDED CONNECTIONS: USE FOR CONNECTIONS TO STRUCTURAL STEEL ONLY. ALL OTHER CONNECTIONS SHALL BE SWAGE HYDRAULIC COMPRESSION FITTINGS. 5.4.3.BONDING STRAPS AND JUMPERS: INSTALL SO VIBRATION BY EQUIPMENT MOUNTED ON VIBRATION ISOLATION HANGERS OR SUPPORTS IS NOT TRANSMITTED TO RIGIDLY MOUNTED EQUIPMENT. BOND STRAPS DIRECTLY TO THE BASIC STRUCTURE TAKING CARE NOT TO PENETRATE ANY ADJACENT PARTS. INSTALL STRAPS ONLY IN LOCATIONS ACCESSIBLE FOR MAINTENANCE. 5.4.4.CONNECTIONS: MAKE CONNECTIONS SO GALVANIC ACTION OR ELECTROLYSIS POSSIBILITY IS MINIMIZED. SELECT CONNECTORS, CONNECTION HARDWARE, CONDUCTORS, AND CONNECTION METHODS SO METALS IN DIRECT CONTACT WILL BE GALVANICALLY COMPATIBLE. 5.4.5.ALL CONDUIT TERMINATION SHALL BE BONDED TO THE EQUIPMENT GROUNDING CONDUCTOR USING A GROUNDING BUSHING WITH LAY-IN LUG AND PROPERLY SIZED GROUND WIRE. 6.SUPPORT, ANCHORAGE, AND ATTACHMENT 6.1.MODULE CLAMPS, NUTS, CAM BRACKET, BASE, MLPE BRACKETS, RAILS, BASES, WASHERS, WIND DEFLECTORS, AND ALL OTHER RACKING COMPONENTS AS REQUIRED SHALL BE SUPPLIED AND COORDINATED BY THE RACKING MANUFACTURER AND INSTALLED BY ELECTRICAL CONTRACTOR. REFER TO RACKING DRAWINGS FOR INSTALLATION MEANS AND METHODS AND SCOPE OF WORK. RACKING MANUFACTURER SHALL PERFORM DYNAMIC WIND TESTS WITH THE SELECTED MODULE AND SHALL INDICATE COMPATIBILITY OF MODULE, COORDINATED BY CONTRACTOR. REQUIRED TORQUE VALUES SHALL BE DOCUMENTED AND COORDINATED. 6.2.PROVIDE SUPPORTS FOR ALL RACEWAYS AS REQUIRED PER NEC, PROVIDE MATERIALS, SIZES AND TYPES OF ANCHORS, AND FASTENERS TO CARRY THE LOADS OF EQUIPMENT AND CONDUIT. HANGERS OR SUPPORTS SHALL BE INSTALLED AT THE HORIZONTAL OR VERTICAL POINT OF CHANGE IN DIRECTION OF ALL CONDUIT RUNS. 6.3.THE FOLLOWING SUPPORT ITEMS SHALL BE HOT DIPPED GALVANIZED FINISH: STRUT, CONDUIT STRAPS, BOLT ROD, THREADED BEAM CLAMPS, RISER CLAMPS, WALL PLATES, SHALL BE HOT DIPPED GALVANIZED FINISH. 6.4.THE FOLLOWING HARDWARE SHALL BE 316, 312, 308 OR 18-8 STAINLESS STEEL: BOLTS, U-BOLTS, NUTS, WASHERS, SPRING WASHERS, CHANNEL NUT WITH SPRING, FENDER WASHER, FLAT WASHER, PV MODULE CLIPS, AND OTHER ASSOCIATED HARDWARE. 6.5.SPRING STEEL, ELECTRO GALVANIZED, AND ZINC PLATED HARDWARE OR SUPPORTS SHALL NOT BE ACCEPTABLE ALTERNATIVE TO THE ABOVE. 6.6.STRUT SHALL BE 12-GAUGE STEEL CHANNELS 1-5/8"X1-5/8", WITH HOLES ON TOP SURFACE, 2 INCHES ON CENTER. 6.7.STRUT FITTINGS AND ACCESSORIES SHALL MATE AND MATCH WITH STRUT. PROVIDE ANGLES AND OTHER STANDARD STRUCTURAL SHAPES. CONNECT WITH MACHINE BOLTS TO FORM RIGID, BONDED SUPPORT STRUCTURES. 6.8.APPLY CORROSION-RESISTANT FINISH TO FIELD-CONNECTIONS, AFTER CUTTING AND THREADING, AND BURIED METALLIC GROUNDING AND BONDING PRODUCTS, AND PLACES WHERE FACTORY APPLIED PROTECTIVE COATINGS HAVE BEEN DESTROYED, WHICH ARE SUBJECTED TO CORROSIVE ACTION. APPLY CORROSION INHIBITOR TO RACKING AS RECOMMENDED BY RACKING MANUFACTURER. 6.9.RATED STRENGTH: ADEQUATE IN TENSION, SHEAR, AND PULLOUT FORCE TO RESIST MAXIMUM LOADS CALCULATED OR IMPOSED UNDER THIS PROJECT, WITH A MINIMUM STRUCTURAL SAFETY FACTOR OF FIVE TIMES THE APPLIED FORCE. 6.10.STEEL SLOTTED SUPPORT SYSTEMS: COMPLY WITH MFMA-3, FACTORY-FABRICATED COMPONENTS FOR FIELD ASSEMBLY, AND PROVIDE FINISH SUITABLE FOR THE ENVIRONMENT IN WHICH INSTALLED. SELECT CHANNEL DIMENSIONS FOR STRUCTURAL LOADING. 6.11.RACEWAY AND CABLE SUPPORTS: AS DESCRIBED IN NECA 1. 6.12.CONDUIT AND CABLE SUPPORT DEVICES: STAINLESS STEEL HANGERS, CLAMPS, AND ASSOCIATED FITTINGS, DESIGNED FOR TYPES AND SIZES OF RACEWAY OR CABLE TO BE SUPPORTED. 6.13.STRUCTURAL STEEL FOR FABRICATED SUPPORTS AND RESTRAINTS: ASTM A 36/A 36M, STEEL PLATES, SHAPES, AND BARS; GALVANIZED. 6.14.FURNISH AND INSTALL POSITIVE LOCKING OF ALL SYSTEM NUTS AND FASTENERS. PROVIDE DOUBLE NUTS, LOCK WASHERS OR LOCKNUTS ON ALL SUSPENDED LOADS SUPPORTS. FINISH TO MATCH APPLICATION. 6.15.TORQUE ALL CONNECTIONS MEETING MANUFACTURER RECOMMENDATIONS AND APPLY TORQUE MARKING ON ALL CONNECTIONS. 6.16.CABLE TIES SHALL BE SUNLIGHT RESISTANT AND RATED FOR OUTDOOR USE. 7.CONDUCTORS AND CABLES 7.1.MATERIALS 7.1.1.CONDUCTOR MATERIAL: COPPER COMPLYING WITH NEMA WC 7; ALL CONDUCTORS SHALL BE SINGLE STRANDED. 7.1.2.CONDUCTOR INSULATION TYPES: CONDUCTORS SHALL HAVE 600V INSULATION TYPE XHHW-2 AND SHALL BE 90C RATED. 7.1.3.MINIMUM SIZE #12 AWG UNLESS OTHERWISE NOTED. 7.1.4.DC CONDUCTOR STRING CABLING SHALL BE 7-STRAND (CLASS B) #10AWG MINIMUM: COPPER, STRANDED UL4703 AS XLP/USE-2 OR RHH/RHW-2 90C, 2000V. UV RATED. 7.1.5.DC CONDUCTOR ABOVE #10: COPPER OR ALUMINUM AS INDICATED, CLASS B STRANDED UL4703 AS XLP/USE-2 OR RHH/RHW-2 90C, 2000V. UV RATED. 7.2.CONDUCTOR CONNECTORS AND SPLICES 7.2.1.DESCRIPTION: FACTORY-FABRICATED CONNECTORS AND SPLICES OF SIZE, AMPACITY RATING, MATERIAL, TYPE, AND CLASS FOR APPLICATION AND SERVICE INDICATED. 7.3.CONDUCTOR INSTALLATION 7.3.1.USE MANUFACTURER-APPROVED PULLING COMPOUND OR LUBRICANT WHERE NECESSARY; COMPOUND USED MUST NOT DETERIORATE CONDUCTOR OR INSULATION. DO NOT EXCEED MANUFACTURER'S RECOMMENDED MAXIMUM PULLING TENSIONS AND SIDEWALL PRESSURE VALUES. 7.3.2.USE PULLING MEANS INCLUDING FISH TAPE, CABLE, ROPE, AND BASKET-WEAVE WIRE/CABLE GRIPS THAT WILL NOT DAMAGE CABLES OR RACEWAY. 7.3.3.MAKE SPLICES AND TAPS THAT ARE COMPATIBLE WITH CONDUCTOR MATERIAL AND THAT POSSESS EQUIVALENT OR BETTER MECHANICAL STRENGTH AND INSULATION RATINGS THAN UNSPLICED CONDUCTORS. 7.3.4.WIRE SIZES SHOWN ON PLANS MAY BE OVERSIZED TO ACCOMMODATE VOLTAGE DROP. CONTRACTOR MAY ELECT TO REDUCE WIRE SIZE WIRE AT SOURCE AND/OR APPLIANCE IN A LISTED MANNER COMPLIANT WITH THE CODE THAT MAY INCLUDE BUT NOT BE LIMITED TO THE INSTALLATION OF JUNCTION BOXES WHICH MAY NOT BE SHOWN ON THE PLAN. 7.3.5.INCREASED CONDUCTOR SIZES SHALL BE COORDINATED WITH TERMINAL SIZES OF EQUIPMENT. CONTRACTOR SHALL PROVIDE LISTED MEANS TO INCREASE CONDUCTOR SIZE WITHIN THE TERMINALS SUCH AS A FERRULE, COMPRESSION SLEEVE, OR OTHER MEANS TO REDUCE CONDUCTOR SIZE COMPATIBLE WITH MECHANICAL TERMINALS. 7.3.6.ALL GROUNDING CONDUCTORS SHALL BE SOFT DRAWN. 8.RACEWAYS AND BOXES 8.1.MATERIALS 8.1.1.EMT: ANSI C80.3. 8.1.2.FLEXIBLE METAL CONDUIT,EMT, FMC: GALVANIZED STEEL TUBING COVERED WITH A LIQUID TIGHT POLYVINYL JACKET. 8.1.3.EMT, POLYVINYL CHLORIDE, PVC SCHEDULE 40: UL 651 8.1.4.FITTINGS FOR CONDUIT (INCLUDING ALL TYPES AND FLEXIBLE AND LIQUIDTIGHT), RGS, AND CABLE: NEMA FB 1; LISTED FOR TYPE AND SIZE RACEWAY WITH WHICH USED, AND FOR APPLICATION AND ENVIRONMENT IN WHICH INSTALLED. 8.2.RACEWAY APPLICATION 8.2.1.RACEWAY FITTINGS: COMPATIBLE WITH RACEWAYS AND SUITABLE FOR USE AND LOCATION. 8.2.2.BELOW GRADE: PVC SCHEDULE 40 CONDUIT NEMA TC2 UL 651, WITH NEMA TC 3 AND UL 51413 FITTINGS. 8.2.3.ABOVE GRADE: EMT 8.2.4.JOIN RACEWAYS WITH FITTINGS DESIGNED AND APPROVED FOR THE PURPOSE AND MAKE JOINTS AND TERMINATIONS TIGHT. WHERE JOINTS CANNOT BE MADE TIGHT, USE BONDING JUMPERS TO PROVIDE ELECTRICAL CONTINUITY OF THE METALLIC RACEWAY SYSTEM. 8.2.5.USE GASKETED LOCKNUTS OR HUBS TO FASTEN CONDUIT TO BOXES IN DAMP AND WET LOCATIONS WHICH ALLOW THE EQUIPMENT TO MAINTAIN ITS NEMA WEATHERPROOF RATING. 8.2.6.PVC CONDUIT TRANSITIONS BETWEEN TWO FIXED POINTS (INCLUDING FROM BELOW GRADE) SHALL INCLUDE CONDUIT EXPANSION FITTING. 8.2.7.EXPANSION FITTINGS SHALL BE PROVIDED ACROSS EXPANSION JOINTS. EXPANSION FITTINGS SHALL HAVE INTEGRAL BONDING JUMPER. 8.2.8.ALL FITTINGS ON EQUIPMENT SHALL BE LISTED TO UL514B AND SHALL BE RATED TO MAINTAIN THE EQUIPMENT NEMA RATING. 8.2.9.PROVIDE NYLON INSULATION BUSHINGS TO PROTECT CONDUCTORS. 8.2.10.CUT CONDUIT SQUARE USING SAW OR PIPE CUTTER AND DE-BURR CUT ENDS. 8.3.BOXES 8.3.1.ALL JUNCTION BOXES FURNISHED BY CONTRACTOR IN NON-CLASSIFIED AREAS SHALL BE NEMA 4X OUTDOORS. 9.IDENTIFICATION OF EQUIPMENT/SIGNAGE 9.1.LABELS SHALL BE EITHER ENGRAVED, PRINTED OR PLATED AND BE OF METALLIC OR PLASTIC VINYL CONSTRUCTION SUCH THAT IT IS WEATHERPROOF, CORROSION PROOF, UV-STABILIZED AND FADE RESISTANT. 9.2.LABEL ATTACHMENT, ADHESIVE, STOCK, AND LAMINATION SHALL BE LISTED TO UL 969. 9.3.ALL LABELS SHALL BE DESIGNED AND USE COLORS, SYMBOLS, AND WORDING AS DEFINED IN ANSI Z535. 9.4.TEXT SHALL BE AS SHOWN BUT TEXT HEIGHT SHALL BE A MINIMUM OF 3/8" FOR TITLES (I.E. "WARNING") AND 3/16" HIGH FOR DATA. 9.5.LABELS SHALL BE INSTALLED AT THE LOCATIONS INDICATED AND AS REQUIRED BY THE NEC. 9.6.ALL MAJOR EQUIPMENT SHALL BE FIELD LABELED USING NAMES INDICATED ON DRAWINGS. 9.7.AT ALL TERMINAL BLOCKS AND HOME RUN LOCATIONS, DC CONDUCTORS SHALL BE LABELED WITH MARKING TAPE IDENTIFYING '+' AND '-' FOR THE POSITIVE AND NEGATIVE CIRCUIT NUMBERS. 9.8.ALL LABELING SHALL COMPLY WITH REQUIREMENTS OF NEC 690, UL, NFPA 70E, ANSI, OSHA, AND IEEE REQUIREMENTS. 10.LOW VOLTAGE DISTRIBUTION EQUIPMENT 10.1.DISCONNECT SWITCHES SHALL BE FUSED OR NONFUSED, AS NOTED. VOLTAGE SHALL BE AS REQUIRED. SWITCHES SHALL BE HEAVY DUTY AND HORSEPOWER RATED FOR MOTOR LOADS. 10.1.1.KNIFE-BLADE TYPE SWITCHES SHALL BE LOAD BREAK, QUICK-MAKE-QUICK-BREAK WITH ARC QUENCHERS, UL CLASS R UP TO 600A. SWITCHES SHALL BE SIMILAR TO EATON DH36, UNLESS OTHERWISE NOTED. 10.2.SWITCHBOARDS 10.2.1.PROVIDE BY SIEMENS, SQUARE-D, EATON, GE, OR SIMILAR. 10.2.2.THIS CRITERIA APPLIES TO ALL DISTRIBUTION EQUIPMENT WITH AN AMPERE RATING EQUAL TO AND GREATER THAN 800A. PROVIDE AMPERE RATING AS NOTED WITH A SHORT CIRCUIT WITHSTAND RATING OF 200,000A. 10.2.3.BUS BARS: PROVIDE HARD DRAWN COPPER, MINIMUM 98% CONDUCTIVITY, SILVER OR TIN PLATED AT JOINTS. CAPACITY SHALL BE AS NOTED. RATINGS FOR MAINS: MINIMUM SHALL BE EQUAL TO SIZE OF MAIN DISCONNECT OR SUPPLY FEEDER PROTECTIVE DEVICE AND CONTINUOUS FULL CAPACITY THROUGHOUT SWITCHBOARD. 10.2.4.SECTIONS: PROVIDE FULL BUS DISTRIBUTION RATING FOR INDICATED AMPACITY. 10.2.5.GROUND BUS: GROUND SHALL BE 25% OF MAINS BUT NOT LESS THAN 1/2 SQ. IN. EXTEND LENGTH OF SWITCHBOARD AND BOLT TO EACH SECTION. LOCATE TO PERMIT DRILLING FOR FUTURE EXTENSION. IN SERVICE SWITCHBOARDS, CONNECT TO NEUTRAL BUS WITH DISCONNECTING LINK. 10.2.6.ENCLOSURE: PROVIDE FRONT ACCESSIBLE GROUP MOUNTED DEVICES. PROVIDE SWITCHING UNITS: AS INDICATED. METAL-ENCLOSED STRUCTURE SHALL BE BOLTED OR WELDED STEEL FRAMING OF SUFFICIENT STRENGTH TO MAINTAIN ALIGNMENT AND WITHSTAND RATED A.I.C. PANELS: PROVIDE PAN TYPE CONSTRUCTION, LOUVERED, MINIMUM NO. 12 USSG STEEL WITH HINGED ACCESS COVERS. PULL BOX (CROWN BOX): ENCLOSURE CONSTRUCTION SHALL BE THE SAME AS SWITCHBOARD WITH REMOVABLE COVERS. BOTTOM SHALL HAVE A MINIMUM 1 IN. APPROVED INSULATING MATERIAL WITH INDIVIDUAL CABLE OPENINGS AND SHALL BE FULLY ACCESSIBLE. CABLE SUPPORTS SHALL BE INSULATED. 10.2.7.FINISH SHALL BE RUST-RESISTIVE BAKED-ON PRIMER AND FINISH COAT OF MANUFACTURER'S SWITCHBOARD GRAY LACQUER, EXCEPT AS NOTED. PROVIDE NAMEPLATES FOR SWITCHBOARD, SWITCHING UNITS AND DEVICES. 10.2.8.CURRENT TRANSFORMER CABINETS: PROVIDE IN ACCORDANCE WITH RULES OF UTILITY COMPANY AND SUBJECT TO ITS APPROVAL. METER PANS: PROVIDE TRANSFORMER TYPE WITH 10-POINT TEST BLOCK COMPLYING WITH UTILITY STANDARDS. 10.2.9.PROVIDE SWITCHBOARD WITH HEATER PACKAGE CONTROLLED VIA HUMIDISTAT AND THERMOSTAT. 10.2.10.SWITCHBOARD SHALL BE SERVICE ENTRANCE RATED. 10.3.PANELBOARDS 10.3.1.BUS BARS SHALL BE HARD DRAWN COPPER, MINIMUM 98 PERCENT CONDUCTIVITY. FOR BLANK (SPACE) COMPARTMENTS, PROVIDE FULL RATED BUS. MINIMUM GUTTER SPACES SHALL BE 5-3/4 I. SIDES, TOP AND BOTTOM, INCREASE FOR THROUGH FEEDERS. GROUND, PHASE, AND NEUTRAL BUS SHALL BE COPPER DIRECTORY HOLDER SHALL BE METAL FRAME WITH CLEAR PLASTIC, TRANSPARENT COVER. PROVIDE A TYPEWRITTEN PANEL SCHEDULE INDICATING FEEDER SIZE, FEEDER MATERIAL, CONDUIT SIZE, CIRCUIT NUMBERS, LOADS SERVED AND THEIR LOCATIONS. 10.3.2.ALL PANELBOARDS SHALL HAVE INTEGRAL SURGE PROTECTION DEVICE (SPD) OF A NOMINAL DISCHARGE RATING OF 100kA OR AS IDENTIFIED LISTED TO UL1449. WHERE 'HYBRID SPD' IS IDENTIFIED ON PLAN, PROVIDE A SPD LISTED TO UL1283, MIL-STD-220A WITH 100kHz ATTENUATION OF OVER 40dB, AND IEEE 62.41 CATEGORY B3 RINGWAVE SHOULD BE <200V L-N. 10.3.3.ALL BUS RATINGS SHALL BE 400A OR GREATER AS IDENTIFIED. 10.3.4.PANELBOARDS SHALL BE NEMA 3R WHERE LOCATED OUTDOORS. PROVIDE SURFACE MOUNTED. 10.3.5.MAINS SHALL BE COMPRESSION LUG TYPE. 10.3.6.ALL MAINS SHALL BE UL489 LISTED AND BE PROVIDED WITH AN LSIG TRIP UNIT. 10.3.7.PANELBOARDS SHALL BE NEMA PB 1 DISTRIBUTION TYPE, WITH ALL BRANCH CIRCUIT BREAKERS AS THE BOLT-ON TYPE. ALL PANELBOARDS SHALL BE PROVIDED WITH DOOR-IN-DOOR CONSTRUCTION. 10.4 TRANSFORMERS 10.4.1 TRANSFORMERS SHALL BE OPEN VENTILATED, DRY TYPE, CLASS 220 INSULATION, 115 DEGREE TEMPERATURE RISE. 10.4.2 TRANSFORMER SHALL BE COMPLETELY ENCLOSED EXCEPT FOR VENTILATING OPENINGS. 10.4.3 WINDINGS SHALL BE COPPER. 10.4.4 PRIMARY AND SECONDARY WINDING SHALL BE DELTA AND WYE, UON. 10.4.5 PROVIDE PRIMARY TAPS: 6-1/2% TAPS, 2 ABOVE AND 4 BELOW RATED VOLTAGE. 10.4.6 HARMONIC CAPABILITY SHALL BE 'K9'. 10.4.7 TRANSFORMER TO COMPLY WITH ANSI C57.96-01.250. 11.TESTING 11.1.ALL DC CONDUCTORS SHALL BE TESTED PER NETA 100.1 INSULATION RESISTANCE TEST AND SHALL READ GREATER THAN 100MOHM. 11.2.PROVIDE FALL OF POTENTIAL 3-POINT TEST INDICATING GROUND RESISTANCE OF LESS THAN 10 OHMS. 11.3.GROUNDING SHALL BE INSTALLED AS INDICATED AND REFLECTED ON STEP AND TOUCH POTENTIAL RISE STUDY PER IEEE 80. J: \ 2 0 2 4 b \ 2 0 2 4 - 0 0 6 7 . 1 1 - r e d _ b u l l _ e l e c t r a d a _ s a n t a _ a n a \ 1 0 - d e s i g n \ D r a w i n g s \ w o r k i n g d o c u m e n t s \ S H E E T S \ L A M I R A D A \ E L E C T R I C A L \ E V - 0 7 . d w g 2 0 2 6 - 0 1 - 1 4 Project Title: Drawing Title: RevisionDateNo. Date: Drawn: Checked: Job No: Scale: Drawing No: SHT:OF BURNS ENGINEERING, INC. | 310-439-5643 300 NORTH CONTINENTAL BLVD SUITE 540 EL SEGUNDO, CA 90245 10 RED BULL ELECTRADA EV CHARGING SANTA ANA 1900 EAST DEERE AVE, SANTA ANA, CA92705 ADDRESS: 1 06/24/2025 CD30 2 07/02/2025 CD90 3 07/15/2025 ISSUE FOR PERMIT 4 01/14/2026 PLAN CHECK COMMENTS ELECTRICAL SPECIFICATIONS 1/14/2026 AS NOTED CS IB 2024.0067.11 EV-07 EV - 0 7 . D W G 7 1 EV-08 MINI-NETWORK BOX (MNB) SPEC SHEET NTS 2 EV-08 EV SUPPLY EQUIPMENT (48A) SPEC SHEET NTS GENERAL NOTES: 1.DETAILS SHOWN ON THIS SHEET ARE TAKEN FROM CUT SHEETS PREPARED BY ELECTRADA. DETAILS ARE REPRESENTITIVE OF THE MANUFACTURES DESIGN AND ARE NOT INTENDED TO BE FOR FABRICATION. OWNER TO FURNISH AND CONTRACTOR INSTALL THE SPECIFIED EQUIPMENT. J: \ 2 0 2 4 b \ 2 0 2 4 - 0 0 6 7 . 1 1 - r e d _ b u l l _ e l e c t r a d a _ s a n t a _ a n a \ 1 0 - d e s i g n \ D r a w i n g s \ w o r k i n g d o c u m e n t s \ S H E E T S \ L A M I R A D A \ E L E C T R I C A L \ E V - 0 9 . d w g 2 0 2 6 - 0 1 - 1 4 Project Title: Drawing Title: RevisionDateNo. Date: Drawn: Checked: Job No: Scale: Drawing No: SHT:OF BURNS ENGINEERING, INC. | 310-439-5643 300 NORTH CONTINENTAL BLVD SUITE 540 EL SEGUNDO, CA 90245 10 RED BULL ELECTRADA EV CHARGING SANTA ANA 1900 EAST DEERE AVE, SANTA ANA, CA92705 ADDRESS: 1 06/24/2025 CD30 2 07/02/2025 CD90 3 07/15/2025 ISSUE FOR PERMIT 4 01/14/2026 PLAN CHECK COMMENTS EQUIPMENT SPEC SHEET 1/14/2026 AS NOTED CS IB 2024.0067.11 EV-08 EV - 0 9 . D W G 8 1 EV-09 BOLLARD NTS J: \ 2 0 2 4 b \ 2 0 2 4 - 0 0 6 7 . 1 1 - r e d _ b u l l _ e l e c t r a d a _ s a n t a _ a n a \ 1 0 - d e s i g n \ D r a w i n g s \ w o r k i n g d o c u m e n t s \ S H E E T S \ L A M I R A D A \ E L E C T R I C A L \ E V - 1 0 . d w g 2 0 2 6 - 0 1 - 1 4 Project Title: Drawing Title: RevisionDateNo. Date: Drawn: Checked: Job No: Scale: Drawing No: SHT:OF BURNS ENGINEERING, INC. | 310-439-5643 300 NORTH CONTINENTAL BLVD SUITE 540 EL SEGUNDO, CA 90245 10 RED BULL ELECTRADA EV CHARGING SANTA ANA 1900 EAST DEERE AVE, SANTA ANA, CA92705 ADDRESS: 1 06/24/2025 CD30 2 07/02/2025 CD90 3 07/15/2025 ISSUE FOR PERMIT 4 01/14/2026 PLAN CHECK COMMENTS DETAILS 1/14/2026 AS NOTED CS IB 2024.0067.11 EV-09 EV - 1 0 . D W G 9 8" X 8" X 1/2" 1 EV-10 EV PEDESTAL SPEC SHEET NTS GENERAL NOTES: 1.DETAILS SHOWN ON THIS SHEET ARE TAKEN FROM CUT SHEETS PREPARED BY ELECTRADA. DETAILS ARE REPRESENTITIVE OF THE MANUFACTURES DESIGN AND ARE NOT INTENDED TO BE FOR FABRICATION. OWNER TO FURNISH AND CONTRACTOR INSTALL THE SPECIFIED EQUIPMENT. J: \ 2 0 2 4 b \ 2 0 2 4 - 0 0 6 7 . 1 1 - r e d _ b u l l _ e l e c t r a d a _ s a n t a _ a n a \ 1 0 - d e s i g n \ D r a w i n g s \ w o r k i n g d o c u m e n t s \ S H E E T S \ L A M I R A D A \ E L E C T R I C A L \ E V - 1 3 . d w g 2 0 2 6 - 0 1 - 1 4 Project Title: Drawing Title: RevisionDateNo. Date: Drawn: Checked: Job No: Scale: Drawing No: SHT:OF BURNS ENGINEERING, INC. | 310-439-5643 300 NORTH CONTINENTAL BLVD SUITE 540 EL SEGUNDO, CA 90245 10 RED BULL ELECTRADA EV CHARGING SANTA ANA 1900 EAST DEERE AVE, SANTA ANA, CA92705 ADDRESS: 1 06/24/2025 CD30 2 07/02/2025 CD90 3 07/15/2025 ISSUE FOR PERMIT 4 01/14/2026 PLAN CHECK COMMENTS EQUIPMENT SPEC SHEET 1/14/2026 AS NOTED CS IB 2024.0067.11 EV-10 EV - 1 3 . D W G 10