Loading...
HomeMy WebLinkAbout2437 S Lowell St - REV 1 - PlanPAGE REV: C 2/23/2026 ACXEL CALI 2437 S LOWELL ST, SANTA ANA, CA, 92707 PROJECT NUMBER: 109R-437CALI SHEET DESIGNER: NITHYA L CUSTOMER RESIDENCE: TEL. (657) 324-1021 APN: 140-153-21 (415) 580-6920 ex3 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 SCOPE OF WORK GENERAL NOTES VICINITY MAPABBREVIATIONS A AMPERE AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT (E)EXISTING ESS ENERGY STORAGE SYSTEM MSP MAIN SERVICE PANEL (N)NEW PRE-FAB PRE-FABRICATED PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS V VOLTS W WATTS SHEET INDEX REV NAME DATE COMMENTS • ALL WORK SHALL GENERALLY CONFORM WITH 2022 CRC/CBC/CEBC, 7-16 ASCE & 2018 NDS, MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH CEC 2022. • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH CEC 2022. • PHOTOVOLATIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.41(A) • MODULES CONFORM TO AND ARE LISTED UNDER UL 61730. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED. • RAPID SHUTDOWN SYSTEM IN COMPLIANCE WITH CEC 2022 690.12(B)(1) WHERE CONDUCTORS OUTSIDE OF THE ARRAY ARE LIMITED TO LESS THAN 30V IN 30 SECONDS AND CEC 2022 690.12(B)(2)(2) WHERE CONDUCTORS INSIDE THE ARRAY BOUNDARY IS LIMITED TO LESS THAN 80V IN 30 SECONDS • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(D). • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 14.29 AMPS MODULE SHORT CIRCUIT CURRENT. • 22.33 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a)(1) & 690.8 (b)]. • ENERGY STORAGE SYSTEM CONFORMS TO AND IS LISTED UNDER UL 9540. • ENERGY STORAGE SYSTEM LIVE PARTS ARE NOT ACCESSIBLE DURING ROUTINE MAINTENANCE. SYSTEM VOLTAGE IN ACCORDANCE WITH CEC 706.20 AND EXCEPTION 1 CEC 706.20 (B). • ADDITIONAL DISCONNECTING MEANS SHALL BE INSTALLED WHERE THE CIRCUITS FROM THESE TERMINALS PASS THROUGH A WALL OR PARTITION PER 706.15(D). • LISTED, COMBINATION TYPE AFCI SHALL BE INSTALLED WHERE BACKED UP CIRCUIT WIRING IS EXTENDED MORE THAN 6FT AND DOES NOT INCLUDE ANY ADDITIONAL OUTLETS OR DEVICES PER CEC 210.12(D). • ALL PASS-THROUGH CONDUCTORS MUST COMPLY WITH CEC 312.8 • THE CAPACITY OF THE STANDALONE SYSTEM SUPPLY SHALL BE EQUAL TO OR GREATER THAN THE LOAD POSED BY THE SINGLE LARGEST UTILIZATION EQUIPMENT CONNECTED TO THE SYSTEM PER CEC ARTICLE 710.15(A) • SYSTEM SIZE: 15.84KW DC, 11.5KW AC • MODULES: (36) SILFAB: SIL-440QD-DCA • RAPID SHUTDOWN: (14) TESLA MID CIRCUIT INTERRUPTER (MCI) ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE • ENERGY STORAGE SYSTEM: (1) TESLA: POWERWALL 3 1707000-XX-Y, 13.5 KWH. (1) TESLA: POWERWALL 3 EXPANSION 1807000-XX-Y TOTAL ENERGY CAPACITY: (IN KWH): 27KWH • BACKUP GATEWAY: (1) 200A TESLA POWERWALL CONTROL PANEL • RACKING: ULTRAFOOT RAIL TO FRAMING SNR-DC-01507 ,ULTRA RAIL, SYSTEM DETAIL, FIXED TILT: SNR-DC-00335 [FLAT, TILT KIT (ROLLED COMP/ MEMBRANE/ FOAM) 1 LAG OMNIBASE] • MAIN PANEL REPLACEMENT: EXISTING 100 AMP MAIN PANEL WITH 100 AMP MAIN BREAKER TO BE REPLACED WITH NEW 225 AMP MAIN PANEL WITH 200 AMP MAIN BREAKER 225AMP BUSBAR. SURGE PROTECTOR TO BE INSTALLED PER MANUFACTURER AND PANEL BOARD SPECS. PAGE # DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-3.0 LAYOUT PV-3.1 MOUNTING DETAIL PV-3.2 MOUNTING DETAIL PV-4.0 ELECTRICAL PV-4.1 ELECTRICAL CONT PV-4.2 ELECTRICAL CALCS PV-4.4 PANEL SCHEDULE PV-5.0 SIGNAGE PV-5.1 SIGNAGE 2 PV-1.0 COVER SHEET C PL PL PL PL PL PL PL PLPLPLPL PL PL A A A A A A A A A A B B B B B B B B B B C C C C C C C C C D D D D D D D PAGE REV: C 2/23/2026 ACXEL CALI 2437 S LOWELL ST, SANTA ANA, CA, 92707 PROJECT NUMBER: 109R-437CALI SHEET DESIGNER: NITHYA L CUSTOMER RESIDENCE: TEL. (657) 324-1021 APN: 140-153-21 (415) 580-6920 ex3 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 ESS SHALL BE INSTALLED 3FT FROM DOORS AND WINDOWS IN ACCORDANCE WITH R328.4. ESS UNITS SHALL BE SEPARATED FROM EACH OTHER BY NOT LESS THAN 3 FEET EXCEPT WHERE SMALLER SEPARATION DISTANCES ARE DOCUMENTED TO BE ADEQUATE BASED ON LARGE/SCALE FIRE TESTING. NOTE: ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE INSTALLED PER CEC 690.12 MAIN PANEL SERVICE ENTRANCESE MP SUB-PANELSP LEGEND SCALE: NTS NOTE: NOT ALL ITEMS IN LEGEND WILL APPEAR IN SITE PLAN ENERGY STORAGE SYSTEM (ESS) GP GENERATION PANEL INVERTER(S) AC DISCONNECT(S) DC DISCONNECT(S) INTERIOR EQUIPMENT SHOWN AS DASHEDINV AC DC METER ADAPTERMA BATTERY BP BACKUP LOADS PANEL MD MICROGRID INTERCONNECT DEVICE PV LOAD CENTERLC METER ADAPTER CONTROLLER APB FRANKLIN APBOX CB IQ COMBINER BOX MAC RDS REMOTE DISCONNECT SWITCH RAIL STANDOFFS & FOOTINGS SOLAR MODULES SITE PLAN - SCALE =1/16" = 1'-0" (E) RESIDENCE (N) ARRAY AR-01 (N) ARRAY AR-02 FIRE SETBACKS (3' TYP) ROOF PATHWAYS (3' TYP) S L O W E L L S T (E) FENCE (E) GATE (TYP) (E) CHIMNEY (TYP) (E) PATIO INV AC MP MD SE RDS BP ROOF PATHWAYS (3' TYP) ARRAY PITCH PV AREA (SQFT) AR-01 10° 608.71 AR-02 29° 146.9390° TRUE AZIM MAG AZIM 258°270° 78° NOTES: ·RESIDENCE DOES NOT CONTAIN ACTIVE FIRE SPRINKLERS. ARRAY DETAILS: ·TOTAL ROOF SURFACE AREA: 3227.119 SQ FT. ·TOTAL PV ARRAY AREA: 755.7 SQ FT. ·PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE AREA) * 100 = 23.41% PV-2.0 SITE PLAN C Signed: 02/24/2026 (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A, 2P 120/240VAC 3 FACILITY GROUND 120/240 VAC SINGLE PHASE SERVICE EXISTING 200A MAIN BREAKER -END FED EXISTING 200A MAIN PANEL 225A BUS M 100A NEW 200A BACKUP GATEWAY GATEWAY 3 (1841000-X1-Y) (N) INTERNAL PANELBOARD WITH(1) (N) 60A PV+ESS BREAKER (1) (N) 100A SUBPANEL FEEDER BREAKER 4 4 A A UL 9540 FACTORY WIRING ASSEMBLY (1 ) TESLA POWERWALL 3 EXPANSION PACK 1807000-xx-y (N) IMO PE69-3020, DISCONNECT SWITCH, 3P, 16A INVERTER: TESLA POWERWALL 3 1707000-XX-Y, ENERGY STORAGE: TESLA:POWERWALL 3 1707000-XX-Y 11500 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT 3 J-BOX 1 1 1 1 36 SILFAB SIL-440QD STRING 1 WITH 7 MODULES WITH 3 MCI COUNT STRING 2 WITH 10 MODULES WITH 4 MCI COUNT STRING 3 WITH 10 MODULES WITH 4 MCI COUNT STRING 4 WITH 9 MODULES WITH 3 MCI COUNT , MODULE LEVEL RAPID SHUTDOWN DEVICES2 • POINT OF INTERCONNECTION: CEC 2022 705.12(B)(3)(2), GATEWAY FEEDER BREAKER AT OPPOSITE END OF BUSBAR • METER NUMBER: 222013-024645 • REPLACE EXISTING 225A / 125A MAIN PANEL WITH NEW 225A /200A MAIN PANEL • EQUIPMENT CHARACTERISTICS INCLUDED IN SPEC SHEETS • NOTE: TOTAL SYSTEM BACKFEED = 60.0A USED FOR INTERCONNECTION CALCULATIONS RSD EXISTING 225A BACKUP LOADS PANEL RELOCATED (E) LOADS PAGE REV: C 2/23/2026 ACXEL CALI 2437 S LOWELL ST, SANTA ANA, CA, 92707 PROJECT NUMBER: 109R-437CALI SHEET DESIGNER: NITHYA L CUSTOMER RESIDENCE: TEL. (657) 324-1021 APN: 140-153-21 (415) 580-6920 ex3 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 PV-4.0 ELECTRICAL C C C C NEW 200 AMP BACKUP GATEWAY 3 EXISTING 200A MAIN PANEL AND 200 A MAIN BREAKER WITH 225A BUSBAR 20 0 MAIN BREAKER GATEWAY FEEDER BREAKER10 0 NEW PV +ESS BREAKER60 EXISTING 225A BACKUP LOAD PANEL 10 0 LIGHTENING / RECEPTACLES15 20 30 40 LIGHTENING / RECEPTACLES LIGHTENING / RECEPTACLES DRYER A/C LIGHTENING / RECEPTACLES15 LIGHTENING / RECEPTACLES20 LIGHTENING / RECEPTACLES20 LIGHTENING / RECEPTACLES15 LIGHTENING / RECEPTACLES15 LIGHTENING / RECEPTACLES15 20 LIGHTENING / RECEPTACLES 20 LIGHTENING / RECEPTACLES 20 LIGHTENING / RECEPTACLES 20 LIGHTENING / RECEPTACLES 20 LIGHTENING / RECEPTACLES 20 LIGHTENING / RECEPTACLES 20 LIGHTENING / RECEPTACLES 20 LIGHTENING / RECEPTACLES SUB BREAKER PAGE REV: C 2/23/2026 ACXEL CALI 2437 S LOWELL ST, SANTA ANA, CA, 92707 PROJECT NUMBER: 109R-437CALI SHEET DESIGNER: NITHYA L CUSTOMER RESIDENCE: TEL. (657) 324-1021 APN: 140-153-21 (415) 580-6920 ex3 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 PANEL SCHEDULE PV-4.3 C LABELING FORMAT LABELS SHALL BE RED PLASTIC MATERIAL WITH ENGRAVED WHITE LETTERS MADE OF DURABLE ADHESIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT. LETTERS SHALL BE MINIMUM 3/8" IN SIZE. CAUTION: 2437 S LOWELL ST, SANTA ANA, CA, 92707 MULTIPLE SOURCES OF POWER PER CODE(S): CEC 2022: 705.10, 710.10 SOLAR PANELS ON ROOF REMOTE DISCONNECT SWITCH AC DISCONNECT SERVICE ENTRANCE WITH GATEWAY FEEDER INVERTER & ENERGY STORAGE SYSTEM (EXT) EXPANSION PACK BACKUP LOADS PANEL (EXT) BACKUP GATEWAY WITH PV+ESS BREAKER (EXT) SIGNAGE 2 PV-5.1 C PAGE REV: C 2/23/2026 ACXEL CALI 2437 S LOWELL ST, SANTA ANA, CA, 92707 PROJECT NUMBER: 109R-437CALI SHEET DESIGNER: NITHYA L CUSTOMER RESIDENCE: TEL. (657) 324-1021 APN: 140-153-21 (415) 580-6920 ex3 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46