Loading...
HomeMy WebLinkAbout3455 S Crawford Glen - Plan (2)FACILITY GROUND 120/240 VAC SINGLE PHASE SERVICE EXISTING 225A MAIN BREAKER -END FED EXISTING 225A MAIN PANEL 225A BUS M UL 9540 FACTORY WIRING ASSEMBLY (1) TESLA: POWERWALL 3 EXPANSION 1807000-XX-Y (N) IMO PE69-3020, DISCONNECT SWITCH, 3P, 16A RSD INVERTER: TESLA POWERWALL 3 1707000-XX-Y, ENERGY STORAGE: TESLA:POWERWALL 3 1707000-XX-Y 11500 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT, POWER CONTROL SYSTEM 3 RSD LOAD RATED DC DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT, POWER CONTROL SYSTEM INVERTER: TESLA POWERWALL 3 1707000-XX-Y, ENERGY STORAGE: TESLA:POWERWALL 3 1707000-XX-Y 11500 WATT INVERTER 3 • POINT OF INTERCONNECTION: CEC 2025 705.13, PCS LOAD BREAKER AT OPPOSITE END OF BUSBAR • METER NUMBER: 322010-419962 • EQUIPMENT CHARACTERISTICS INCLUDED IN SPEC SHEETS • NOTE: TOTAL SYSTEM BACKFEED = 120.0A USED FOR INTERCONNECTION CALCULATIONS NEW 200A BACKUP GATEWAY 3 1841000-X1-Y WITH 175A MAIN BREAKER (N) INTERNAL PANEL BOARD WITH (N)(2) 60A PV AND ESS BREAKERS 6 A A NEW 225A BACK UP LOADS PANEL WITH 175A MAIN BREAKER RELOCATED (E) LOADS 4 (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A , 2P 120/240VAC 3 (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A , 2P 120/240VAC 3 (N)TESLA REMOTE METER SITE PV CURRENT TRANSFORMER J-BOX 1 1 2 J-BOX 1 1 2 13 SILFAB: SIL-440QD-DCA STRING 1 WITH 13 MODULES WITH 5 MCI COUNT MODULE LEVEL RAPID SHUTDOWN DEVICES 10 SILFAB: SIL-440QD-DCA STRING 1 WITH 10 MODULES WITH 4 MCI COUNT MODULE LEVEL RAPID SHUTDOWN DEVICES 10 SILFAB: SIL-440QD-DCA STRING 1 WITH 10 MODULES WITH 4 MCI COUNT MODULE LEVEL RAPID SHUTDOWN DEVICES 10 SILFAB: SIL-440QD-DCA STRING 1 WITH 10 MODULES WITH 4 MCI COUNT MODULE LEVEL RAPID SHUTDOWN DEVICES 5 FEED - THRU LUG KIT PAGE REV: F 2/26/2026 JULIE VO 3455 S CRAWFORD GLEN, SANTA ANA, CA, 92704 PROJECT NUMBER: 109R-455VO PR-3004660114 SHEET DESIGNER: SREERAJ P R CUSTOMER RESIDENCE: TEL. (309) 660-0844 APN: 412-531-51 (415) 580-6920 ex3 #ESTAMP#SSTAMP 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 ELECTRICAL PV-4.0 F CONDUIT SCHEDULE TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT 1 Inverter Input (2) 10 AWG (PV WIRE)N/A 6 AWG (BARE) Open Air 2 Inverter Input (4) 10 AWG THHN/THWN-2 N/A 8 AWG THHN/THWN-2 3/4 EMT 3 Inverter Output (2) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT 4 Gateway Output (2) 2/0 AWG THHN/THWN-2 (1) 2/0 AWG THHN/THWN-2 6 AWG THHN/THWN-2 1-1/2 EMT 5 BACKUP LOADS (18) 12 AWG THHN/THWN-2 (18) 12 AWG THHN/THWN-2 8 AWG THHN/THWN-2 2 EMT(4) 10 AWG THHN/THWN-2 (2) 10 AWG THHN/THWN-2 8 AWG THHN/THWN-2 (4) 8AWG THHN/THWN-2 (2) 8AWG THHN/THWN-2 8 AWG THHN/THWN-2 6 Feed Thru Lugs (2) 2/0 AWG THHN/THWN-2 (1) 2/0 AWG THHN/THWN-2 6 AWG THHN/THWN-2 1-1/2 EMT PAGE REV: F 2/26/2026 JULIE VO 3455 S CRAWFORD GLEN, SANTA ANA, CA, 92704 PROJECT NUMBER: 109R-455VO PR-3004660114 SHEET DESIGNER: SREERAJ P R CUSTOMER RESIDENCE: TEL. (309) 660-0844 APN: 412-531-51 (415) 580-6920 ex3 #ESTAMP#SSTAMP 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 ELECTRICAL CONT. INSTALLER MUST CHECK THE CONDITION, INSTALLABILITY AND CODE COMPLIANCE OF EXISTING EQUIPMENT. General Notes: • CITY REQUIRES TWO SOURCES OF GROUND - UFER, TWO GROUNDS RODS OR COLD WATER GAS BOND • INSTALL THE BACKED UP LOAD CONDUCTORS AND THE MICROGRID INTERCONNECTION DEVICE BREAKER CONDUCTORS IN TWO SEPARATE CONDUITS. ANY MULTIWIRE BRANCH CIRCUITS RELOCATED ARE TO BE IDENTIFIED, GROUPED, AND EQUIPPED WITH A 2-POLE OCPD BREAKER PER CEC 210.4(B,D). IF THE RELOCATED LOADS EXTEND MORE THAN 6 FEET, AFCI PROTECTION APPLIES PER CEC 210.12 POWER CONTROL SYSTEM (PCS): A PCS IS INSTALLED IN ACCORDANCE WITH CEC 2025 705.13 THE PCS SHALL LIMIT GENERATION SOURCE OUTPUT SUCH THAT CURRENT FROM ALL SOURCES OF SUPPLY DOES NOT EXCEED THE RATING OF ANY BUSBAR OR CONDUCTOR SUPPLIED BY THE POWER PRODUCTION SOURCES • ANY BUSBAR OR CONDUCTOR ON THE LOAD SIDE OF THE SERVICE DISCONNECT NOT MONITORED BY THE PCS SHALL COMPLY WITH ARTICLE 705.12. ACCESS TO PCS CONTROLS IS RESTRICTED TO QUALIFIED PERSONS IN ACCORDANCE WITH 240.6(C). ENERGY STORAGE SYSTEM: (2) TESLA: POWERWALL 3 1707000-XX-Y ENABLE PCS SETPOINTS: - 180A - MAXIMUM TOTAL CURRENT ON THE CONTROLLED PANEL - 0A - FAIL SAFE GENERATION BACKFEED CURRENT SUPPLY (120% COMPLIANT) MODULE CHARACTERISTICS SILFAB: SIL-440QD-DCA 440 W OPEN CIRCUIT VOLTAGE 38.97 V MAX POWER VOLTAGE 33.41 V SHORT CIRCUIT CURRENT 14.22 A PV-4.1 F F PAGE REV: F 2/26/2026 JULIE VO 3455 S CRAWFORD GLEN, SANTA ANA, CA, 92704 PROJECT NUMBER: 109R-455VO PR-3004660114 SHEET DESIGNER: SREERAJ P R CUSTOMER RESIDENCE: TEL. (309) 660-0844 APN: 412-531-51 (415) 580-6920 ex3 #ESTAMP#SSTAMP 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 ELECTRICAL CALCS Inverter Calculations Each Inverter has the following values which are calculated following these formulas: Inverter X: •Max DC Circuit Current = (Module Isc) x (High Irradiance)(690.8(A)(1)(a)) •Max AC Output Current = (Max Inverter Output) •OCPD Needed = (Max AC Output Current) x 1.25 •System Characteristics: •Operating Voltage = (Module Vmp) x (# Modules / String) •Max Open Circuit Voltage = [((Temp Coef Voc) x (Voc)) / 100] x (Low Temp - STC Temp) + Voc * (# Modules / String) •Operating Current = (Module Imp) x (# Strings) •Short Circuit Current = 1.25 x (Module Isc) x (# Strings) Inverter Powerwall 3 1707000-xx-y •Max DC Circuit Current = 17.46A •Max AC Output Current = 48A •OCPD Needed = 60A •System Characteristics: •Operating Voltage = 405.73V •Max Open Circuit Voltage = 535.10V •Operating Current = 25.96A •Short Circuit Current = 35.55A Inverter Powerwall 3 1707000-xx-y •Max DC Circuit Current = 17.46A •Max AC Output Current = 48A •OCPD Needed = 60A •System Characteristics: •Operating Voltage = 312.11V •Max Open Circuit Voltage = 411.62V •Operating Current = 25.96A •Short Circuit Current = 35.55A Combinded Inverter Output: •Max AC Output Current = 96 •OCPD Needed = 120 Inverter Overcurrent Protection: (Inverter(s) Max Combined Current) x (Continuous Load) = 96 A x 1.25 = 120.0 A → 150 A Overcurrent Protection Allowable Backfeed: Max Allowed Total Generation Backfeed OCPD = Main Breaker Rating = 225 A 150 A ≤ 225 A → Interconnection Meets CEC 2025 705.13 Requirements Wire Calculations Wire ampacity calculated from CEC 310.16/310.17 as appropriate with ambient temperature calculations from CEC 310.15(B)(1) and raceway fill adjustments from CEC 310.15(C)(1). Conduit on the roof shall be installed no less than 1" above the roof deck. PV Circuit conductor ampacity is constrained using the 75°C column with the continuous duty uprating or the 90°C column with the relevant ambient temperature and raceway fill adjustments without the continuous duty uprating per 690.8(B), whichever is the lower value will govern conductor sizing. Non-PV Circuit Conductors use the ampacity in the 75°C column or the 90°C column with the relevant ambient temperature and raceway fill adjustments, whichever is less (110.14(C) & 310.15(A)(2)). The rating of the conductor after adjustments shall be greater than, or equal to, the continuous duty uprated current. Calc Ex: Wire Ampacity x Ambient Temp. Corr. Factor x Conduit Fill Adj. Factor >= Output Current •Tag 1: Inverter Input: 10 AWG rated 35.00A, 35.00A >= 21.82A •Tag 2: Inverter Input: 10 AWG rated 35.00A, 29.12A >= 21.82A •Tag 3: Inverter Output: 6 AWG rated 65.00A, 65.00A >= 60.00A •Tag 4: Gateway output: 2/0 AWG rated 175.00A, 175.00A >= 175.00A PV-4.2 •Tag 6: Feed Thru Lug: 2/0 AWG rated 175.00A, 175.00A >= 175.00A •Tag 5: Backup loads: 8 AWG rated 50.00A, 50.00A >= 50.00A F PAGE REV: F 2/26/2026 JULIE VO 3455 S CRAWFORD GLEN, SANTA ANA, CA, 92704 PROJECT NUMBER: 109R-455VO PR-3004660114 SHEET DESIGNER: SREERAJ P R CUSTOMER RESIDENCE: TEL. (309) 660-0844 APN: 412-531-51 (415) 580-6920 ex3 #ESTAMP#SSTAMP 2500 WHITE RD. SUITE A, IRVINE CA 92614 PHONE 805.540.7603 FAX 949.215.7778 CA CL #750184 GILBERT CORREIA, C10, C46 PANEL SCHEDULE 70 17 5 NEW 225A BACKUP LOADS PANEL WITH 175A MAIN BREAKER EXISTING 225A MAIN PANEL WITH 225A MAIN BREAKER AND 225A BUSBAR 22 5 60 NEW 200A BACKUP GATEWAY WITH 175A MAIN BREAKER SUB PANEL MAIN BREAKER NEW PV + ESS BREAKER 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 AC RANGE KIT KIT DISPOSAL DISHWASHER HOOD DK GDO DRYER LIGHTING/RECEPTACLE SEC REFRIGERATOR FAU REFRIGERATOR MICRO GFI LAUNDRY LIGHTING/RECEPTACLE MAIN BREAKER 60 NEW PV + ESS BREAKER 40 30 40 30 OVEN GFI FAU PV-4.4 FEED THRU LUG 17 5 MAIN BREAKER F