HomeMy WebLinkAbout600 W Santa Ana Blvd - PlanSHEET INDEX ·EXISTING COMMERCIAL TENANT IMPROVEMENT. ·REPLACE LIKE TO-LIKE HVAC UNITS. M000 M100 TM00 MECHANICAL NOTES MECHANICAL TITLE 24 - 1 TM01 MECHANICAL PLAN MECHANICAL TITLE 24 - 2 SYMBOLS AND ABBREVIATIONS T RETURN AIR PLENUM CROSS-SECTION SUPPLY AIR PLENUM CROSS-SECTION EXHAUST AIR CUBIC FEET PER MINUTE EXTERNAL STATIC PRESSURE SIDE WALL RETURN GRILLE THERMOSTAT SUPPLY DIFFUSER SIDE WALL SUPPLY REGISTER RETURN AIR GRILLE EXHAUST AIR GRILLE / CEILING EXHAUST FAN ESP CFM EA EXISTING FIRE DAMPER HORSEPOWER HERTZ RETURN AIR TYPICAL SUPPLY AIR MANUAL VOLUME DAMPER OUTSIDE SUPPLY AIR SMOKE DETECTOR STATIC PRESSURE FULL LOAD AMPERES VOLT UNDERCUT DOOR UP THRU ROOF MVD V TYP U.T.R. SD SA SP RA OSA FLA HP HZ EXIST FD SD NOTE: REFER TO PLAN SHEETS FOR ANY ADDITIONAL LEGEND, SYMBOLS AND RELATED ABBREVIATIONS. D U S SENSOR EF (E) ROOF MOUNTED EXHAUST FAN NEWNEW(N) U/C CO2 SENSORCO2 1 RTU MECHANICAL EQUIPMENT TAG POC NEW DUCT EXISTING DUCT CONDENSATE DRAINCD REFRIGERANT LINEREF OSA INTAKE OSA DUCTOSA FD CO SENSORCO FIRE SMOKE DAMPERFSDFSD ABBR.SYMBOL DESCRIPTION CONDENSATE DRAIN CLEANOUT HVAC SPECIFICATIONS PIPE INSULATION THICKNESS 4. 5. 6. 1. 7. 2. 3. CONCEALED SPACES, CIRCULATION AIR INSULATION OF DUCTS FLUID TEMP. RANGE (°F) CONDUCTIVITY RANGE (BTU-"/HR PER SQFT/°F) INSULATION MEAN RATING TEMP. (°F) NOMINAL PIPE DIAMETER (") INSULATION THICKNESS REQUIRED (") <1 1 TO <1.5 1.5 TO <4 4 TO <8 8 AND LARGER 251-350 350< 201-250 141-200 105-140 40-60 <40 SPACE COOLING SYSTEMS (CHILLED WATER, REFRIGERANT AND BRINE) SPACE HEATING, HOT WATER SYSTEMS AND SERVICE WATER HEATING SYSTEMS 0.32-0.34 0.29-0.31 0.27-0.30 0.25-0.29 0.22-0.28 0.21-0.27 0.20-0.26 250 200 150 125 100 75 50 4.5 3.0 2.5 1.5 1.0 1.0 5.0 4.0 2.5 1.5 1.5 1.5 5.0 4.5 2.5 2.0 1.5 1.5 5.0 4.5 3.0 2.0 1.5 1.5 5.0 4.5 3.0 2.0 1.5 1.5 A MAINTENANCE LABEL SHALL BE AFFIXED TO MECHANICAL EQUIPMENT AND A MAINTENANCE MANUAL SHALL BE PROVIDED TO THE OWNER PER STANDARDS. EXCEPT AS ALLOWED, THESE CONTROLS SHALL BE ADJUSTABLE TO PROVIDE A DEAD BAND OF 5 DEGREES F BETWEEN FULL HEATING AND FULL COOLING. CONTROLS SHALL HAVE THE CAPABILITY OF TERMINATING ALL HEATING AT A TEMPERATURE NO MORE THAN 70 DEGREES F AND OF TERMINATING ALL COOLING AT A TEMPERATURE NOT LESS THAN 78 DEGREES F. EACH HVAC SYSTEM SHALL BE PROVIDED WITH AT LEAST ONE AUTOMATIC TEMPERATURE CONTROL DEVICE FOR THE REGULATION OF TEMPERATURE THESE AUTOMATIC TEMPERATURE CONTROL DEVICES SHALL BE CAPABLE OF BEING SET TO MAINTAIN SPACE TEMPERATURE SET POINTS FROM 55 DEGREES F TO 85 DEGREES F, SHALL BE CAPABLE OF OPERATING THE SYSTEM HEATING AND/OR COOLING IN SEQUENCE. EXCEPTIONS: (1)FACTORY-INSTALLED PIPING WITHIN SPACE CONDITIONING EQUIPMENT; (2)PIPING THAT CONVEYS FLUIDS THAT HAVE A DESIGN OPERATING TEMPERATURE RANGE BETWEEN 60 DEGREES AND 105 DEGREES FAHRENHEIT; (3)WHERE THE HEAT GAIN OR HEAT LOSS TO OR FROM PIPING WITHOUT INSULATION WILL NOT INCREASE BUILDING SOURCE ENERGY USE; (4)PIPING THAT PENETRATES FRAMING MEMBERS SHALL NOT BE REQUIRED TO HAVE PIPE INSULATION FOR THE DISTANCE OF THE FRAMING PENETRATION. METAL PIPING THAT PENETRATES METAL FRAMING SHALL USE GROMMETS, PLUGS, WRAPPING OR OTHER INSULATING MATERIAL TO ASSURE THAT NO CONTACT IS MADE WITH THE METAL FRAMING. INSPECTION TO BE MADE AND DUCTWORK APPROVED BEFORE COVERING WITH INSULATION. TRANSVERSE SUPPLY DUCTS, TAPED OR SEALED WITH MASTIC EXCEPT FOR DUCTS EXPOSED TO CONDITIONED SPACE, WHERE DUCT STATIC PRESSURE EXCEEDS 3/4" WATER, LONGITUDINAL JOINTS, TAPED OR SEALED WITH MASTIC. SEALING INSPECTION PIPE INSULATION SPACE-CONDITIONING AND SERVICE WATER-HEATING SYSTEM SHALL BE INSULATED IN ACCORDANCE WITH THE FOLLOWING TABLE: INSULATED WIRES, PLASTIC TUBING OR PIPING, PIPE INSULATION, CONDENSATE PAN INSULATION, WOOD, PVC, ABS AND OTHER PLASTICS) TO BE IN CONCEALED SPACES USED TO CONVEY CIRCULATING AIR SUPPLY. WHEN COMBUSTIBLE MATERIAL IS TO BE LOCATED IN THE ABOVE SPACES, IT SHALL BE APPROVED FOR SUCH INSULATION. TEMPERATURE CONTROLS PORTIONS OF SUPPLY-AIR AND RETURN-AIR DUCTS CONVEYING HEATED OR COOLED AIR LOCATED IN ONE OR MORE OF THE FOLLOWING SPACES SHALL BE INSULATED TO A MINIMUM INSTALLED LEVEL OF R-8: 1.OUTDOORS; OR 2.IN A SPACE BETWEEN THE ROOF AND AN INSULATED CEILING; OR 3.IN A SPACE DIRECTLY UNDER A ROOF WITH FIXED VENTS OR OPENINGS TO THE OUTSIDE OR UNCONDITIONED SPACES; OR 4.IN AN UNCONDITIONED CRAWL SPACE; OR 5.IN OTHER UNCONDITIONED SPACES. PORTIONS OF SUPPLY-AIR DUCTS THAT ARE NOT IN ONE OF THESE SPACES, INCLUDING DUCTS BURIED IN CONCRETE SLAB, SHALL BE INSULATED TO A MINIMUM INSTALLED LEVEL OF R-4.2 OR BE ENCLOSED IN DIRECTLY CONDITIONED SPACE. NONRES 0.5 RES 0.75 1.01.0 1.0 1.ALL WORK SHALL CONFORM TO MECHANICAL CODE, BUILDING CODE AND ALL OTHER APPLICABLE CITY CODES AND REGULATIONS. 2.THE CONTRACTOR SHALL PAY FOR ALL PERMITS AND FEES. 3.CONTROL LOW VOLTAGE WIRING BY MECHANICAL CONTRACTOR AND CONDUIT BY ELECTRICAL CONTRACTOR. 4.CONDENSATE DRAIN PIPING AND FINAL CONNECTION TO UNIT BY PLUMBING CONTRACTOR. 5.G.C. TO VERIFY CURRENT ELECTRICAL POWER CONDITION IN FIELD BEFORE PURCHASING ANY MECHANICAL EQUIPMENT. 6.CONTRACTOR TO VERIFY MECHANICAL HEATING EQUIPMENT TO BE CONFORM TO LOCAL EPA STANDARD BEFORE PURCHASING EQUIPMENT. 7.ACCURATE AS-BUILT DRAWINGS SHALL BE MADE DURING CONSTRUCTION AND SUBMITTED FOR APPROVAL UPON COMPLETION OF INSTALLATION. 8.THE CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR FOR SIZE AND LOCATION OF DUCTWORK ROOF OPENINGS AND WITH ELECTRICAL CONTRACTOR FOR ELECTRICAL REQUIREMENTS OF ALL MECHANICAL EQUIPMENT AND ARCHITECTURAL DRAWINGS FOR AIR DISTRIBUTION LOCATION. 9.THE CONTRACTOR SHALL SUBMIT BID BASED ON THE DRAWINGS AND ALTERNATE FOR COST SAVING. THESE DRAWINGS ARE FOR BIDDING PURPOSES. 10.THE CONTRACTOR SHALL FURNISH ALL MATERIALS, LABOR, EQUIPMENT, TRANSPORTATION AND SERVICES NECESSARY FOR COMPLETION OF THE WORK. ALL MATERIALS AND WORK SHALL COMPLY WITH APPLICABLE CODES AND GOVERNING REGULATIONS AND MEET THE APPROVAL OF THE LOCAL JURISDICTION. 11.TAKE ALL PRECAUTIONS NECESSARY TO PROTECT THE MATERIALS BEFORE, DURING AND AFTER INSTALLATION. IN THE EVENT OF DAMAGE, IMMEDIATELY REPAIR ALL DAMAGED AND DEFECTIVE WORK TO THE APPROVAL OF THE ARCHITECT AT NO ADDITIONAL COST TO THE OWNER. 12.THESE DRAWINGS ARE DIAGRAMMATIC. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING HIS WORK WITH ALL OTHER TRADES. THIS INCLUDES COORDINATING THE LOCATION AND SIZE OF ALL OPENINGS, LOCATIONS OF EQUIPMENT PADS AND CHANGES OF ELEVATIONS OF DUCTWORK, PIPING AND OTHER EQUIPMENT. 13.ANY MATERIAL, ARTICLE OR PIECE OF EQUIPMENT OTHER THAN THAT INDICATED SHALL NOT BE USED UNLESS APPROVED IN WRITING BY THE ENGINEER AND ANY CHANGES IN MECHANICAL, ELECTRICAL AND/OR OTHER SYSTEMS REQUIRED DUE TO SUCH SUBSTITUTION SHALL BE THE RESPONSIBILITY OF THE HVAC CONTRACTOR; AND AT NO ADDITIONAL COST TO THE OWNER. 14.THE CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING TO VERIFY LOCATIONS AND SIZES OF ALL EXISTING EQUIPMENT AND INFORM THE ARCHITECT AND ENGINEER OF ANY DISCREPANCIES. 15.CONTRACTOR TO VERIFY ADEQUATE PLUMBING CONNECTIONS ARE READILY AVAILABLE FOR EVAPORATIVE COOLERS AND GAS HEATING SYSTEMS BEFORE PURCHASING EQUIPMENT. 16.COORDINATE ENTIRE INSTALLATION OF THE H.V.A.C. SYSTEM WITH THE WORK OF ALL OTHER TRADES PRIOR TO ANY FABRICATION OR INSTALLATION. PROVIDE ALL FITTINGS, OFFSETS, AND TRANSITIONS AS REQUIRED FOR A COMPLETE WORKABLE INSTALLATION. 17.WARRANTIES; 1-YEAR WARRANTY FOR EQUIPMENT, 5-YEAR COMPRESSORS. REFER TO CONSTRUCTION CONTRACT FOR OTHER APPLICABLE WARRANTIES. 18.EQUIPMENT SPECIFICATION AND INTERLOCK DIAGRAM SHALL BE SUBMITTED FOR APPROVAL PRIOR TO PURCHASE OF EQUIPMENT FOR INSTALLATION. 19.ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. PROVIDE ALL FITTINGS, TRANSITIONS, DAMPERS, VALVES AND OTHER DEVICES REQUIRED FOR A COMPLETE WORKABLE INSTALLATION. 20.HEATING, VENTILATING, AND AIR-CONDITIONING SYSTEMS SHALL BE BALANCED BY A LICENSED T&B CONTRACTOR IN ACCORDANCE WITH ONE OF THE FOLLOWING METHODS (CMC 314.1): ·AABC NATIONAL STANDARDS FOR TOTAL SYSTEM BALANCE ·ACCA MANUAL B ·ASHRAE 111 ·NEBB PROCEDURAL STANDARDS FOR TESTING ADJUSTING BALANCING OF ENVIRONMENTAL SYSTEMS ·SMACNA HVAC SYSTEMS TESTING, ADJUSTING AND BALANCING 21.PROVIDE FILTER FOR AIR CONDITIONING AND/OR AIR SIDE UNITS AS REQUIRED PER ASHRAE AND MECHANICAL CODE. 22.THERMOSTAT SHALL BE 24 VOLT, ONE STAGE HEATING AND ONE OR TWO STAGE COOLING WITH MATCHING SUBBASE AND TAMPER PROOF COVER. 23.CONDENSATE PIPING SHALL BE SIZED IN ACCORDANCE WITH MECHANICAL CODE. 24.AUTOMATIC FIRE DAMPER REQUIREMENTS ARE AS FOLLOWS: a.PROVIDE AUTOMATIC FIRE DAMPERS AT ALL PENETRATIONS OF FIRE-RATED CEILINGS AND WALLS THROUGHOUT. CONTRACTOR SHALL COORDINATE WITH FIRE-RATED CEILING AREAS AND WALLS AS INDICATED ON ARCHITECTURAL DRAWINGS. THIS NOTE SHALL TAKE PRECEDENCE OVER ANY OMISSIONS ON THE DRAWINGS. SEE SPECIFICATIONS. b.LOCATION OF FIRE-RATED CEILINGS AND WALLS ARE AS INDICATED ON THE ARCHITECTURAL DRAWINGS. CA GREEN BUILDING NOTES HVAC GENERAL NOTES MECHANICAL CODE ·2022 CALIFORNIA MECHANICAL CODE ·2022 CALIFORNIA ENERGY CODE 26.CONDENSATE WASTE SHALL CONNECT INDIRECTLY TO THE DRAINAGE SYSTEM THROUGH AN AIR GAP OR AIR BREAK TO PROPERLY TRAPPED AND VENTED RECEPTORS, DRY WELLS, OR THE TAILPIECE OF A PLUMBING FIXTURE. 27.WHERE CONDENSATE WASTE FROM AIR CONDITIONING COILS DISCHARGES BY DIRECT CONNECTION TO A LAVATORY TAILPIECE OR TO AN APPROVED ACCESSIBLE INLET ON A BATHTUB OVERFLOW, THE CONNECTION SHALL BE LOCATED IN AN AREA CONTROLLED BY THE SAME PERSON CONTROLLING THE AIR-CONDITIONED SPACE. 28.THE REFRIGERATION EQUIPMENT REFRIGERANT SERVICE PORTS LOCATED OUTDOORS SHALL BE FITTED WITH LOCKING TYPE TAMPER RESISTANT CAPS OR SHALL BE PROTECTED FROM UNAUTHORIZED ACCESS BY A MEANS ACCEPTABLE TO THE ENFORCING AGENCY. 29.THE HEATING AND COOLING DUCT SYSTEM IS SIZED IN ACCORDANCE WITH ASHRAE. 30.G.C. TO VERIFY SUFFICIENCY OF DUCT SPACE BEFORE PURCHASING ANY MECHANICAL EQUIPMENT. 31.DUCTWORK SHALL BE INSULATED OR LINED AS NOTED ON DRAWINGS. ALL DUCTWORK EXPOSED ON ROOF SHALL BE INTERNALLY LINED UNLESS OTHERWISE INDICATED OR SPECIFIED. ALL DUCT SIZES ARE SHEET METAL SIZES. ALL DUCT JOINTS SHALL BE SEALED PER SPECIFICATIONS. 32.CONNECT MAIN DUCT TO AIR CONDITIONING UNIT WITH WEATHERPROOF FLEXIBLE CONNECTION. SUN SHIELD OVER ENTIRE FLEXIBLE CONNECTIONS REQUIRED IF FLEXIBLE CONNECTION IS EXPOSED TO WEATHER. 33.ALL LINED DUCT DIMENSIONS ARE NET CLEAR DIMENSION AFTER LINING HAS BEEN INSTALLED. 34.ALL DUCTWORK SIZE SHOWN ON PLAN ARE INTERIOR DIAMETER. CONTRACTOR SHALL ADD INSULATION THICKNESS INTO CONSIDERATION BEFORE INSTALLATION. 35.DUCTS SHALL BE SUPPORTED WITH 1" WIDE 16-GAUGE HANGER STRAPS AND SHALL BE SPACED AT NO MORE THAN 7'-0" ON CENTERS AND SHALL BE SECURED TO STRUCTURAL MEMBER. EXPOSED DUCTWORK ON ROOF SHALL BE SUPPORTED BY GALVANIZED STEEL ANGLE & SHALL BE PER LOCAL CODE. 36.ROUND AND RECTANGULAR DUCTWORK ARE INTERCHANGEABLE IF CROSS SECTION AREAS ARE EQUIVALENT. CONTRACTOR IS TO VERIFY THE EXACT CEILING SPACE AND INTERCHANGE THE DUCT SIZE TO FIT THE CEILING SPACE WITHOUT ADDITIONAL FEE CHARGE. 37.ALL FACTORY-FABRICATED DUCT SYSTEMS SHALL COMPLY WITH UL 181 FOR DUCTS AND CLOSURE SYSTEMS, INCLUDING COLLARS, CONNECTIONS, AND SPLICES, AND BE LABELED AS COMPLYING WITH UL 181. 38.INSTALL VOLUME CONTROL DAMPERS AT EACH SUPPLY DIFFUSER TO AFFORD COMPLETE CONTROL OF THE AIR FLOW IN THE VARIOUS DUCT SYSTEMS. INSTALL SPLITTER DAMPER AT DUCT TAKEOFFS AND DAMPER AS REQUIRED. 39.COORDINATE THE LOCATION OF ALL CEILING DIFFUSERS, REGISTERS AND GRILLES WITH THE ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL LIGHTING LAYOUT AND ARCHITECTURAL ROOM ELEVATIONS. 40.ALL CEILING DIFFUSERS ARE 4-WAY UNLESS OTHERWISE NOTED. 41.PROVIDE BACK-DRAFT DAMPER FOR ALL EXHAUST AIR DUCT UNLESS OTHERWISE NOTED PER CODE. 42.EXHAUST TERMINATION SHALL BE MINIMUM 10'-0" AWAY OR 3'-0" ABOVE FROM ANY FRESH AIR INTAKE, OPERABLE WINDOWS, DOORS AND 10'-0" MINIMUM ABOVE GRADE. 43.PROVIDE ALL FRESH AIR INTAKES AND EXHAUST OUTLETS WITH HOOD, 1/2" GALVANIZED MESH SCREENS AND OUTSIDE AIR BACK-DRAFT DAMPERS. 44.ALL HVAC UNITS OR SYSTEMS SERVING A COMMON AIR SPACE MUST BE INTERCONNECTED TO SHUT DOWN IMMEDIATELY UPON ALARM CONDITION FROM DUCT DETECTORS (OR FIRE ALARM SYSTEM WHEN USING AREA SMOKE DETECTORS IN LIEU OF DUCT DETECTORS) WITHOUT INTERFERENCE FROM EMS OR ANY OTHER SYSTEMS. ALL CONTROL RELAYS USED FOR SHUT DOWN MUST BE APPROVED BY STATE OR LOCAL JURISDICTION FOR RELEASING SERVICE. 45.PURCHASING PARTY SHALL ENSURE THE MOTOR SPECS PRIOR TO ORDERING EXHAUST SYSTEM TO ENSURE THE PANEL IS BUILT CORRECTLY. 46.REDWOOD SLEEPER OR PLATFORM FOR ROOF MOUNTED UNIT, DUCT PENETRATION, CUTTING AND PATCHING BY GENERAL CONTRACTOR, UNLESS OTHERWISE NOTED ON PLAN. 47.42" MINIMUM GUARDS TO BE PROVIDED WHEN ROOF MOUNTED OR ROOF ACCESS EQUIPMENT THAT REQUIRE SERVICE ARE LOCATED WITHIN 10' OF A ROOF EDGE OR OPEN SIDE OF A WALKING SURFACE AND SUCH EDGE OR OPEN SIDE IS LOCATED MORE THAN 30" ABOVE THE ROOF SURFACE. 48.CONTRACTOR SHALL SUBMIT A COMPLETE BALANCE REPORT FOR APPROVAL. SYSTEMS AIR BALANCE SHALL BE PERFORMED BY AN INDEPENDENT AIR BALANCE CONSULTANT. A CERTIFIED AABC OR NEBB. THE REPORT SHALL INCLUDE THE FOLLOWING: a.AIR QUANTITIES AT EACH REGISTER. b.STATIC PRESSURE READINGS AT INLET AND DISCHARGE OF EACH AIR HANDLING SYSTEM AND AT INLET OF EACH EXHAUST AIR SYSTEM. c.COOLING AND HEATING SUPPLY AND RETURN AIR TEMPERATURES AT EACH AIR CONDITIONING UNIT. 5.504.1 TEMPORARY VENTILATION: IF THE HVAC SYSTEM IS USED DURING CONSTRUCTION, USE RETURN AIR FILTERS WITH A MERV OF 8, BASED ON ASHRAE 52.2-1999, OR AN AVERAGE EFFICIENCY OF 30% BASED ON ASHRAE 52.1-1992. REPLACE ALL FILTERS IMMEDIATELY PRIOR TO OCCUPANCY. APPLIES TO ADDITIONS OR ALTERATIONS. 5.504.3 COVERING OF DUCT OPENINGS AND PROTECTION OF MECHANICAL EQUIPMENT DURING CONSTRUCTION: AT THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE CONSTRUCTION SITE AND UNTIL FINAL STARTUP OF THE HEATING, COOLING AND VENTILATING EQUIPMENT, ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC,SHEET METAL OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO REDUCE THE AMOUNT OF DUST, WATER AND DEBRIS WHICH MAY ENTER THE SYSTEM. 5.504.5.3 FILTERS: IN MECHANICALLY VENTILATED BUILDINGS, PROVIDE REGULARLY OCCUPIED AREAS OF THE BUILDING WITH AIR FILTRATION MEDIA FOR OUTSIDE AND RETURN AIR PRIOR TO OCCUPANCY THAT PROVIDES AT LEAST A MERV OF 13. 5.506.1 OUTSIDE AIR DELIVERY: FOR MECHANICALLY OR NATURALLY VENTILATED SPACES IN BUILDINGS, MEET THE MINIMUM REQUIREMENTS OF SECTION 120.1 OF THE CALIFORNIA ENERGY CODE AND CHAPTER 4 OF CCR, TITLE 8, OR THE APPLICABLE LOCAL CODE, WHICHEVER IS MORE STRINGENT. 5.508.1.1.CHLOROFLUOROCARBONS ( CFCs): INSTALL HVAC, REFRIGERATION AND FIRE SUPPRESSION EQUIPMENT THAT DO NOT CONTAIN CFCs. 5.508.1.2.HALONS: INSTALL HVAC, REFRIGERATION AND FIRE SUPPRESSION EQUIPMENT THAT DO NOT CONTAIN HALONS. ADIMINISTRATIVE REQUIREMENTS: A.THE PERSON WITH OVERALL RESPONSIBILITY FOR CONSTRUCTION OR THE PERSON RESPONSIBLE FOR THE INSTALLATION OF REGULATED FEATURES, MATERIALS, COMPONENTS, OR MANUFACTURED DEVICES SHALL POST, OR MAKE AVAILABLE WITH THE BUILDING PERMIT(S) ISSUED FOR THE BUILDING, THE REQUIRED INSTALLATION CERTIFICATE(S) FOR FEATURES, MATERIALS, COMPONENTS, OR MANUFACTURED DEVICES REGULATED BY THE APPLIANCE EFFICIENCY REGULATIONS OR PART 6. SUCH INSTALLATION CERTIFICATE(S) SHALL BE MADE AVAILABLE TO THE ENFORCEMENT AGENCY FOR ALL APPROPRIATE INSPECTIONS. THESE CERTIFICATES SHALL: A.1.IDENTIFY FEATURES, MATERIALS, COMPONENTS, OR MANUFACTURED DEVICES REQUIRED TO VERIFY COMPLIANCE WITH THE APPLIANCE EFFICIENCY REGULATIONS AND PART 6. A.2.INCLUDE A STATEMENT INDICATING THAT THE FEATURES, MATERIALS, COMPONENTS, OR MANUFACTURED DEVISE CONFORM TO THE APPLIANCE EFFICIENCY REGULATIONS AND PART 6 AND THE REQUIREMENTS FOR SUCH FEATURES, MATERIALS, COMPONENTS, OR MANUFACTURED DEVICES GIVEN IN THE PLANS AND SPECIFICATIONS APPROVED BY THE LOCAL ENFORCEMENT AGENCY. A.3.STATE THE NUMBER OF THE BUILDING PERMIT UNDER WHICH THE CONSTRUCTION OR INSTALLATION WAS PERFORMED. B.WITHIN 90 DAYS AFTER ISSUANCE OF CERTIFICATE OF OCCUPANCY RECORD DRAWINGS SHALL BE PROVIDED TO THE OWNER. IF A BUILDING DESIGN FEATURE, MATERIAL, COMPONENT OR MANUFACTURED DEVICE IS CHANGED BEFORE FINAL CONSTRUCTION AND INSTALLATION, SUCH THAT THE BUILDING MAY NO LONGER COMPLY WITH PART 6, THE BUILDING MUST BE BROUGHT INTO COMPLIANCE, AND SO INDICATED ON AMENDED PLANS AND CERTIFICATE OF COMPLIANCE(S) THAT SHALL BE SUBMITTED FOR APPROVAL. C.THE BUILDER SHALL PROVIDE THE BUILDING OWNER OR THE PERSON(S) RESPONSIBLE FOR BUILDING MAINTENANCE (IN CASE OF MULTI-TENANT OR CENTRALLY OPERATED BUILDINGS) AT OCCUPANCY THE FOLLOWING: C.1.OPERATING INFORMATION: THE APPROPRIATE CERTIFICATE(S) OF COMPLIANCE AND A LIST OF THE FEATURES, MATERIALS, COMPONENTS, AND MECHANICAL DEVICES INSTALLED IN THE BUILDING AND INSTRUCTIONS ON HOW TO OPERATE THEM EFFICIENTLY. C.2.MAINTENANCE INFORMATION: REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY STATED AND INCORPORATED ON A READILY ACCESSIBLE LABEL. THE LABEL MAY BE LIMITED TO IDENTIFYING THE OPERATION AND MAINTENANCE MANUAL. C.3.VENTILATION INFORMATION: A DESCRIPTION OF THE QUANTITIES OF OUTDOOR AND RECIRCULATED AIR THAT THE VENTILATION SYSTEMS ARE DESIGNED TO PROVIDE TO EACH AREA. MANDATORY MEASURES: A.(IF APPLICABLE) MANUFACTURED FENESTRATION AND EXTERIOR DOORS SHALL MEET ALL LISTED REQUIREMENTS IN SEC 10-111-(A) UNDER SECTION 110.6(A) OF PART 6. TEMPORARY LABELS FOR MANUFACTURED FENESTRATION SHALL HAVE A CLEARLY VISIBLE TEMPORARY LABEL AND SHALL COMPLY WITH LABELING REQUIREMENTS OF NFRC 700. NO OTHER VALUES FOR U-FACTOR, SHGC, VT AND AIR LEAKAGE ARE ALLOWED ON THE TEMPORARY LABEL ATTACHED TO THE MANUFACTURED FENESTRATION PRODUCT OR EXTERIOR DOOR. B.(IF APPLICABLE) RATED FENESTRATION SHALL HAVE A PERMANENT LABEL CONSISTENT WITH THEIR RATING AND CERTIFICATION THAT IS EITHER A STAND-ALONE LABEL, AN EXTENSION OR TAB OF AN EXISTING PERMANENT CERTIFICATION LABEL BEING USED BY THE MANUFACTURER/RESPONSIBLE PARTY, OR A SERIES OF MARKS OR ETCHINGS ON THE PRODUCT. C.JOINTS, PENETRATIONS AND OTHER OPENINGS IN THE BUILDING ENVELOPE THAT ARE POTENTIAL SOURCES OF AIR LEAKAGE SHALL BE CAULKED, GASKETED, WEATHER STRIPPED, OR OTHERWISE SEALED TO LIMIT INFILTRATION AND EXFILTRATION. D.ALL INSULATING MATERIAL SHALL BE INSTALLED IN COMPLIANCE WITH THE FLAME-SPREAD RATING AND SMOKE DENSITY REQUIREMENTS OF THE CBC. E.NON-CENTRALIZED ENERGY MANAGEMENT SYSTEMS SHALL HAVE SETBACK THERMOSTATS; CAPABLE TO PROGRAM TEMPERATURE SETPOINTS FOR AT LEAST FOUR PERIODS WITHIN A 24-HR. PERIOD. F.ALL RECIRCULATED AIR OR OUTDOOR AIR SUPPLIED TO OCCUPIABLE SPACES IS FILTERED (MINIMUM MERV 13) BEFORE PASSING THROUGH ANY AIR CONDITIONING COMPONENT; THE LESSER OF THE MINIMUM RATE OF OUTDOOR AIR REQUIRED BY SEC. 120.1 (C), OR THREE COMPLETE AIR CHANGES SHALL BE SUPPLIED TO THE ENTIRE BUILDING DURING THE ONE-HOUR PERIOD IMMEDIATELY BEFORE THE BUILDING IS NORMALLY OCCUPIED. G.ALL MECHANICAL VENTILATION AND SPACE-CONDITIONING SYSTEMS SHALL BE DESIGNED WITH DUCTWORK, DAMPERS, AND CONTROLS WHICH ALLOWS OUTSIDE AIR RATES TO BE OPERATED AT THE LARGER OF (1) THE MINIMUM LEVELS SPECIFIED IN SECTION 120.1(C)3 OR (2) THE RATE REQUIRED FOR MAKE-UP OF EXHAUST SYSTEMS THAT ARE REQUIRED FOR AN EXEMPT OR COVERED PROCESS, FOR CONTROL OF ODORS, OR FOR THE REMOVAL OF CONTAMINANTS WITHIN THE SPACE. MEASURED OUTSIDE AIR RATES OF CONSTANT AND VARIABLE VOLUME MECHANICAL VENTILATION SYSTEMS SHALL BE WITHIN 10% OF OUTSIDE AIR RATE SHOWN ON TABLE 120.1-A. H.THE THERMOSTATIC CONTROLS FOR HVAC SYSTEMS SHALL BE CAPABLE OF BEING SET LOCALLY OR REMOTELY BY TO CONTROL COMFORT HEATING DOWN TO 55 °F OR LOWER AND COOLING UP TO 85°F OR HIGHER. THE THERMOSTATIC CONTROLS SHALL BE CAPABLE OF PROVIDING A DEAD BAND RANGE OF AT LEAST 5 °F WITHIN WHICH HEATING AND COOLING ENERGY TO THE ZONE IS SHUT OFF OR REDUCE TO A MINIMUM. I.OUTDOOR AIR SUPPLY AND EXHAUST EQUIPMENT SHALL BE INSTALLED WITH DAMPERS THAT AUTOMATICALLY CLOSE UPON FAN SHUTDOWN. J.AIR DISTRIBUTION SYSTEM DUCTS AND PLENUMS, INCLUDING, BUT NOT LIMITED TO, BUILDING CAVITIES, MECHANICAL CLOSETS, AIR-HANDLER BOXES AND SUPPORT PLATFORMS USED AS DUCTS OR PLENUMS, SHALL BE INSTALLED, SEALED AND INSULATED TO MEET THE REQUIREMENTS OF CHAPTER 6 CMC CODE AND ANSI/SMACNA -006-2006 HVAC DUCT CONSTRUCTION STANDARDS METAL AND FLEXIBLE. SUPPLY-AIR DUCTS CONVEYING HEATED OR COOLED AIR SHALL BE INSULATED TO A MINIMUM INSTALLED LEVEL OF R-4.2 (R-8 IN UNCONDITIONED SPACE), UNLESS DUCTS ARE IN CONDITIONED SPACE. K.MAXIMUM LENGTH OF FLEXIBLE DUCT AND CONNECTORS SHALL NOT BE MORE THAN 5 FEET. FLEXIBLE DUCTS SHALL NOT BE USED IN LIEU OF RIGID ELBOWS. L.EACH SPACE-CONDITIONING SYSTEM SHALL BE INSTALLED WITH CONTROLS (1) CAPABLE OF AUTOMATICALLY SHUTTING OFF THE SYSTEM DURING PERIODS OF NON-USE AND SHALL HAVE (A) 4-HR TIMER OR; (B) OCCUPANCY SENSORS OR; (C) AUTO TIME SWITCH CONTROLS AND ACCESSIBLE MANUAL OVERRIDE FOR UP TO 4-HRS. (2) AUTOMATICALLY RESTART AND TEMPORARILY OPERATE THE SYSTEM TO MAINTAIN SETBACK THERMOSTAT SETPOINTS FOR MECHANICAL HEATING AND COOLING. (3) MULTIPURPOSE, CLASSROOMS CONFERENCE, CONVENTION, AUDITORIUM AND MEETING CENTER ROOMS OF CERTAIN SIZE WHICH DO NOT HAVE PROCESSES OR OPERATIONS THAT GENERATE DUSTS, FUMES, VAPORS OR GASSES SHALL BE EQUIPPED WITH OCCUPANT SENSOR(S) TO ACCOMPLISH THE FOLLOWING DURING UNOCCUPIED PERIODS (A) AUTOMATICALLY SETUP THE OPERATING COOLING TEMPERATURE SET POINT BY 2°F OR MORE AND SETBACK THE OPERATING HEATING TEMPERATURE SET POINT BY 2˚F OR MORE AND; (B) AUTOMATICALLY RESET THE MINIMUM REQUIRED VENTILATION RATE WITH AN OCCUPANT SENSOR VENTILATION CONTROL DEVICE ACCORDING TO SECTION 120.1(C)5. (4) HOTEL AND MOTEL GUEST ROOMS SHALL HAVE CAPTIVE CARD KEY CONTROLS, OCCUPANCY SENSING CONTROLS, OR AUTOMATIC CONTROLS SUCH THAT, NO LONGER THAN 30 MINUTES AFTER THE GUEST ROOM HAS BEEN VACATED, SETPOINTS ARE SETUP AT LEAST +5°F (+3°C) IN COOLING MODE AND SET-DOWN AT LEAST -5°F (-3°C) IN HEATING MODE. M.ALL DUCTWORK AND PLENUMS WITH PRESSURE CLASS RATINGS SHALL BE CONSTRUCTED TO SEAL CLASS A. JOINTS AND SEAMS OF DUCT SYSTEMS AND THEIR COMPONENTS SHALL NOT BE SEALED WITH CLOTH-BACK RUBBER ADHESIVE DUCT TAPES UNLESS SUCH TAPE IS USED IN COMBINATION WITH MASTIC AND DRAWBANDS. EXCEPTION TO SECTION 120.4(B)1D: DUCTWORK LOCATED IN OCCUPIED SPACE AND EXPOSED TO VIEW IS NOT REQUIRED TO MEET SEAL CLASS A. CA TITLE 24 NOTES LESS THAN 12 26/.022 .025 13-30 26/.022 .025 31-36 24/.023 .026 FOOTNOTES: FOR GALVANIZED STEEL (SMACNA TABLE 1-4/E5) MAXIMUM 1" W.G. STATIC POSITIVE AND NEGATIVE DUCT GAUGE SELECTIONS MINIMUM THICKNESS ALUMINUM (INCHES) MINIMUM THICKNESS GALVANIZED IRON (U.S. GAUGE/INCHES) DUCT DIAMETER (INCHES) 1. HEATING AND AIR CONDITIONING UNITS NOT EXCEEDING 2000 CFM OR ONE INCH WATER GAUGE (WG) POSITIVE OR NEGATIVE PRESSURE. DUCT FITTINGS SHALL BE CONSTRUCTED OF MATERIAL NOT LESS THAN THE GAUGE OF THE DUCT. 2. DUCTWORK AND FITTINGS LARGER THAN TWENTY INCHES SHALL BE CONSTRUCTED TO THE GAUGING REQUIREMENTS OF ANSI SMACNA 006-2020 HVAC DUCT CONSTRUCTION STANDARDS. CA TITLE 24 NOTES MANDATORY MEASURES: N. DUCT SYSTEMS SHALL COMPLY WITH SUBSECTION 1 OR 2 BELOW: 1.NEW DUCT SYSTEMS THAT MEET THE CRITERIA IN SUBSECTIONS A, B, C AND D BELOW SHALL BE SEALED TO A LEAKAGE RATE NOT TO EXCEED 6 PERCENT OF THE NOMINAL AIR HANDLER AIRFLOW RATE AS CONFIRMED THROUGH HERS FIELD VERIFICATION AND DIAGNOSTIC TESTING, IN ACCORDANCE WITH REFERENCE NONRESIDENTIAL APPENDIX NA7.5.3; N.1.THE DUCT SYSTEM DOES NOT SERVE A HEALTHCARE FACILITY; AND N.2.THE DUCT SYSTEM PROVIDES CONDITIONED AIR TO AN OCCUPIABLE SPACE FOR A CONSTANT VOLUME, SINGLE ZONE, SPACE-CONDITIONING SYSTEM; AND N.3.THE SPACE-CONDITIONING SYSTEM SERVES LESS THAN 5,000 SQUARE FEET OF CONDITIONED FLOOR AREA; AND N.4.THE COMBINED SURFACE AREA OF THE DUCTS LOCATED OUTDOORS OR IN UNCONDITIONED SPACE IS MORE THAN 25 PERCENT OF THE TOTAL SURFACE AREA OF THE ENTIRE DUCT SYSTEM. 2.NEW DUCT SYSTEMS THAT ARE NOT SUBJECT TO TESTING UNDER SECTION 120.4(G)1 SHALL INSTEAD MEET THE DUCT LEAKAGE TESTING REQUIREMENTS OF CMC SECTION 603.9.2. P. OCCUPANT SENSOR VENTILATION CONTROL DEVICES. OCCUPANT SENSING OR VENTILATION CONTROLS ARE REQUIRED FOR SPACE CONDITIONING ZONES THAT ARE BOTH PERMITTED TO HAVE THEIR VENTILATION AIR REDUCED TO ZERO WHILE IN OCCUPIED STANDBY MODE PER TABLE 120.1-A AND REQUIRED TO INSTALL OCCUPANT SENSORS TO COMPLY WITH SECTION 130.1(C)5, 6, AND 7. OCCUPANT SENSOR VENTILATION CONTROL DEVICES USED TO REDUCE THE RATE OF OUTDOOR AIRFLOW WHEN OCCUPANTS ARE NOT PRESENT SHALL COMPLY WITH THE FOLLOWING: P.1.OCCUPANT SENSORS SHALL HAVE SUITABLE COVERAGE AND PLACEMENT TO DETECT OCCUPANTS IN THE ENTIRE SPACE VENTILATED. IN 20 MINUTES OR LESS AFTER NO OCCUPANCY IS DETECTED BY ANY SENSORS COVERING THE ROOM, OCCUPANT SENSING CONTROLS SHALL INDICATE A ROOM IS VACANT. P.2.WHEN OCCUPANT SENSORS CONTROLLING LIGHTING ARE ALSO USED FOR VENTILATION, THE VENTILATION SIGNAL SHALL BE INDEPENDENT OF DAYLIGHTING, MANUAL LIGHTING OVERRIDES OR MANUAL CONTROL OF LIGHTING. P.3.WHEN A SINGLE ZONE DAMPER OR A SINGLE ZONE SYSTEM SERVES MULTIPLE ROOMS, THERE SHALL BE AN OCCUPANT SENSOR IN EACH ROOM AND THE ZONE SHALL NOT BE CONSIDERED VACANT UNTIL ALL ROOMS IN THE ZONE ARE VACANT. P.4.ONE HOUR PRIOR TO NORMAL SCHEDULED OCCUPANCY, THE OCCUPANT SENSOR VENTILATION CONTROL SHALL ALLOW PRE-OCCUPANCY PURGE AS DESCRIBED IN SECTION 120.1(D)2. P.5.WHEN THE ZONE IS SCHEDULED TO BE OCCUPIED AND OCCUPANT SENSING CONTROLS IN ALL ROOMS AND AREAS SERVED BY THE ZONE INDICATE THE SPACES ARE UNOCCUPIED, THE ZONE SHALL BE PLACED IN OCCUPIED STANDBY MODE. P.6.IN 5 MINUTES OR LESS AFTER ENTERING OCCUPIED-STANDBY MODE, MECHANICAL VENTILATION TO THE ZONE SHALL BE SHUT OFF UNTIL THE SPACE BECOMES OCCUPIED OR UNTIL VENTILATION IS NEEDED TO PROVIDE SPACE HEATING OR CONDITIONING. WHEN MECHANICAL VENTILATION IS SHUT OFF TO THE ZONE, THE VENTILATION SYSTEM SERVING THE ZONE SHALL REDUCE THE SYSTEM OUTSIDE AIR RATE BY THE AMOUNT OF OUTSIDE AIR REQUIRED FOR THE ZONE. P.7.WHERE THE SYSTEM PROVIDING SPACE CONDITIONING ALSO PROVIDES VENTILATION TO THE ZONE, IN 5 MINUTES OR LESS AFTER ENTERING OCCUPIED-STANDBY MODE, SPACE CONDITIONING ZONE SETPOINTS SHALL BE RESET IN ACCORDANCE WITH SECTION 120.2(E)3. SCOPE OF WORK RE V I S I O N CI V I C C E N T E R PLOT DATE: 2/13/2026 6:03:43 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 60 0 W S A N T A A N A B L V D SA N T A A N A , C A 9 2 7 0 1 DRAWN:CHECKED: SCALE:DATE: 08/24/2025 SHEET TITLE: PL A N C H E C K R E V . 0 2 / 1 1 / 2 0 2 6 M000 MECHANICAL NOTES C.B.A.N. LIBRARY OFFICE 7 OFFICE 6OFFICE 12 OFFICE 40 OFFICE 41 OFFICE 42 OFFICE 48 MECHANICAL PLAN WATER-COOLED SELF-CONTAINED AIR CONDITIONER MARK MANUFACTURER MODEL TYPE TON CFM GPM PD (FT WG) COOLING HEATING ELECTRICAL WEIGHT (LBS) DIMENSIONS (WxDXH) (INCHES)TOTAL (BTUH) SENSIBLE (BTUH)EER EWT/LWT (°F)EAT (°F)LAT (°F)EWT (°F)LWT (°F)V/PH/HZ MCA MOCP AC -1 CARRIER 50VQP240BAM6CDDM VERTICAL 20 8,000 56 11.2 246,400 192,510 15.11 86 / 96.8 80DB / 67WB 57.7 160 180 460 / 3 / 60 42.7 50 1310 80 X 33 X 68 AC -2 CARRIER 50VQP240BAM6CDDM VERTICAL 20 8,000 56 11.2 246,400 192,510 15.11 86 / 96.8 80DB / 67WB 57.7 68 105 460 / 3 / 60 42.7 50 1310 80 X 33 X 68 NOTES: 1 THERMOSTATS INSTALLED AT 48"AFF. 2 EXTEND CONDENSATE DRAIN DIRECTLY TO A LOCAL CODE APPROVED RECEPTOR. 3 INSTALL PER MANUFACTURER'S MANUAL. 4 PROVIDE WITH WATERSIDE ECONOMIZER. 5 THE AIR FILTERS FOR OUTSIDE AND RETURN AIR HAVE A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 13 6 VERIFY COOLING AND HEATING EWT/LWT IN FIELD. # EQ 1 AC 2 AC 1 1 #KEYED PLAN NOTES: 1.RECONNECT ALL EXISTING DUCTWORK AND PIPING IN KIND. MATCH SIZE, MATERIAL, INSULATION, ROUTING, AND REQUIRED SLOPES; PROVIDE TRANSITIONS/FITTINGS AS NEEDED; CONTRACTOR TO VERIFY IN FIELD. 2.EXISTING 6" CONCRETE PAD AND STRUCTURAL FRAME BASE TO REMAIN. ATTACH NEW UNIT TO THE EXISTING FRAME. GENERAL NOTES: 1.IF DRAWINGS ARE INCORRECT FROM THE ACTUAL SITE CONDITION, CONTRACTOR SHALL NOTIFY ENGINEER(S) AND PROVIDE INFORMATION REFLECTING ACTUAL CONDITIONS. 2.ENVIRONMENTAL EXHAUST TERMINATION TO BE MINIMUM 3 FEET FROM A PROPERTY LINE, 10 FEET FROM A FORCED AIR INLET, AND 3 FEET FROM OPENINGS INTO THE BUILDING. N.T.S. SCALE:UNIT ATTACHMENT DETAIL 1 2 2 RE V I S I O N CI V I C C E N T E R PLOT DATE: 2/13/2026 6:03:45 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 60 0 W S A N T A A N A B L V D SA N T A A N A , C A 9 2 7 0 1 DRAWN:CHECKED: SCALE:DATE: 08/24/2025 SHEET TITLE: PL A N C H E C K R E V . 0 2 / 1 1 / 2 0 2 6 M100 1/4" = 1'-0" MECHANICAL PLAN C.B.A.N. MECHANICAL TITLE 24 - 1 RE V I S I O N CI V I C C E N T E R PLOT DATE: 2/13/2026 6:04:11 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 60 0 W S A N T A A N A B L V D SA N T A A N A , C A 9 2 7 0 1 DRAWN:CHECKED: SCALE:DATE: 08/24/2025 SHEET TITLE: PL A N C H E C K R E V . 0 2 / 1 1 / 2 0 2 6 TM00 MECHANICAL TITLE 24 - 1 C.B.A.N. 600 W SANTA ANA BLVD, SANTA ANA, CA 92701 MECHANICAL TITLE 24 - 2 RE V I S I O N CI V I C C E N T E R PLOT DATE: 2/13/2026 6:03:46 PM CD I Ci r c a D o m i n i I n t e r n a t i o n a l , I n c . En g i n e e r i n g - C o n s u l t i n g 98 9 0 R e s e a r c h D r . S u i t e 1 0 0 , I r v i n e , C A 9 2 6 1 8 Ph o n e ( 9 4 9 ) 3 3 6 - 6 6 3 6 | d k a n g @ c d i e n g . c o m 60 0 W S A N T A A N A B L V D SA N T A A N A , C A 9 2 7 0 1 DRAWN:CHECKED: SCALE:DATE: 08/24/2025 SHEET TITLE: PL A N C H E C K R E V . 0 2 / 1 1 / 2 0 2 6 TM01 MECHANICAL TITLE 24 - 2 C.B.A.N. 9890 RESEARCH DR. SUITE 100 IRVINE, CA 92618 9890 RESEARCH DR. SUITE 100 IRVINE, CA 92618 M42652 2/13/2026 2/13/2026 ANDY NHAN ANDY NHAN 600 W SANTA ANA BLVD, SANTA ANA, CA 92701