Loading...
HomeMy WebLinkAbout101105850 - PermitCity of Santa Ana 20 Crvrc Center Plaza (M-19), Santa Ana, C492702 !Bu ild ing Permrt Counter: (714\ 647-5800 lnspection Requests (714) 667-2738 lnspector Section: (714) 647-5853 ?( Permit #: I O{ I O585O Pin #: 76741 Project Address: 745 W Aster Pl Assessor's Parcel. 002-291-49 Lot: 13 Bldg Tract: 16905 Address Range Block NA Building Use: Job Type: Nature of Work: Existing Bldg. & Use Proposed Use. Single Family Dwelling Solar Solar SFD Watt garage R-3, U V B, SPK cBc 2019 x-0602320144J 1st FL Area 2nd FL Area Other Areas. Garage Area Total Patio: T.l.Area: Yards Req'd Valuation: S14,400.00 Occupancy: Consk Type: Code: Flood Zone: # of Stories: 0 Description of Work: lnstall solar panels Planning Conditions: Owner: Address: Phone. Tenant Lam Dang 745 W Aster Santa Ana, CA 92706 (909) 772-434s Conlractor: South West Sun Solar, lnc. Address: 13752 Harbor Blvd Garden Grove, CA 92843 Phoner (714) 582-3909 State Lac #: 1004667 Lic Type: B, C-10, C-20, C-38, C-39 Bus. Lic #: 350754 Workers' Compensation lnsurancel Carrier: StarnetlnsuranceCompany Policy #: BNUWC0151378 Expires. 0610112021 Engineer Address Phone: License # Architecl / Desiqner: Address: lm Planning Approval By: Plan Checked By: Permit lssued By: NPDES lnsp. Req'd: PWA lnsp Req'd: Planning lnsp. Req'd: Landscaping lnsp. Req'd Hernandez, Kathy Date: Date: Dale: O2lOgl2O21 Subject to Field: Misc Receipt Misc. Receipt Misc. Receipt $450.00 $4 05 $1.00 $0.00 07176002 5150I Permil Fee 07776002 s7770 Microfilm Records 07176002 s1672 Bldg Stds. Revolving 07776002 51600 Gene:al Plan Update\t}'\NO No No No Fire lnsp. Req'd: Police lnsp Req'd Flood Zone Cert. Req'd: No No No Account#Total Every pemil tssued shall bocomo nvahcl unlesslhe wod< on lhe stte aulhonzed by such pemit is cofifienced wilhn 360 days aftet ils issuance or if lhe worl< authonzed on lhe stte by such pemtl 6 suspended or abandoned lor a period of360 days after lhe ttrne lhe work ts commenced $455.05 $0.00 $455.0s lnspector MtD# 2021-164162 01116002 51601 01 1 16002 5'1612 01116002 57770 $450 00 $1.00 $4.05 Fee Total Paid lo Date: Balance Due Unit:Suite Range: Zoning: SD77Historic No Phone: License # +:xtxlr*{li*}r BUILDING. INSPECTOR RECORD SITE.WORK DATE tD/sE. l COMMENTS ()r\ \t.R l lr rn x lrl l.{ \I\ll()\ IlErcbylritnldsl.olry.fl)c,urythdI{ncicr$fronrh.cohdoilLalnrtsrorrh.followitrEu$n(Sc?011.J Br(ims{ rd Phlc\sinn C.dc): Any Cny or G'$ry whKh ,.qotcs i Frnn 'o o.{rLt. rhd, i,r{mvc, deml'rh q rlun u, (Nrur.. lnor k, irs h\u!rr. ule r.quiEsrhc lndtanr lorsu.hFm lonL r sisicd dcft rhr tror ilE h lic..rd plrsuMt rotlE Eovisionr.l rlE O,nrrrrois Lics{d L5w (Cn fl.r 9- (otrErcins *irh "q*i6n 7UI) of DiiinrolrhcBr r$ Mrl Pdlssnnr C.dc) or rhlr lEor.hc irctcmpr lhcronon\,{ !h. bdri\ rorrhcdlLSctlcxcmrlion Aryviololionol'Ssrbn70ll5byony qdic.nl ii,r ! IE rril {tFls l,r .mliclnl lo. civil FMllyot ml mE lfid nvc htr lEal {tolln lsrm). l. r ou Er 6l rhc FoFny. .* m, .trlpl,)rcs wirh ea!.\ a rh.ir w* dnn|rnuio., *rll rl! 0r wnk and r,r srnrrm i! .Fl i fln d o. orTcr.rl tu sk (.*L 7Ur{. Bu!'r$ and ltl'ac$6N GrlC Th. Cdnadr'\ l-iccns ltr* drs {!p/yn,!no*m.ol rh.FnrFny wh. hurld! M in{h)rs trEN)tr onl s&' dc skh w hinrclior h.rslior rtmlsh hn or &r o*nrn{'k,ycc\, fl)vildl rhi rurh 'nlnrlmnk m n d.nlcl d orlctn for sL ll houcrd th. toillin3 or ,.pn*urnt n dd wnitu or r{ of(onpLriotr rh OeEr Bxild.r w'll hrw th. htr&n of F,virq rh r fu or \h. dil rn tnnl, or iritn,E llE nr{rny hr th. purlr's ol _1. !s o*ncr .l rhc rfuIl.n), !m cxclusivcly connrd ina { irh licrn{-J .ontr.lnA r. .o.nrud rll ,)mj(r rse 7o+1. Bunms rl Ptn{L\rm Cdcr'lhc Conrr{ror\ l-kc.!c tiu dcs.rtr qT,ly ro !n.sRr ofprolany*h, blil.l\ or rml,r{tr!\ rh.mn. 3n'l *ho co rrls tu such lroFcl \ wirh a ftntrrl,'n!) liccnwd nuroo t,rhcCo t{ctntljccn{tjw) I xtr,r\.n,1 ttrrLr s(atu II &P( r,tr rh(r.r\r Dflt. o$m. w( rRxFRs' c(tlllPF-Nsa rl(lN u[l;LaMrl.lr! Lrr.hy Jltnl uod.r F-nulry oftEJury om ot rhc liill,,wi'r* J\-.l[trri,,n\ . -l hlec ud $ill Bid.in r Ccnituurc oI Grsni lo Sclt lnm td w,Ios coqE,rdiJn, .r l,svxkn fo b, Serli,n l'r{ro or 'lxtih, Col., for llt FrlunaNc ol rtr wo hr whi.n llE rflnir n niu.n !l hrk .nd will isiduin wolkcn r.nvEns irn iNunmc,6 Rrlund hys.crhn lr{Dof lh. L,hor Co&. tor rlE pc.rol11mc of . Krt tu *hth 'hh Fmril N L$ucd My eo&6r' orlEr.ltun insun*. cui.r.td Flicy oun$s t ,-,",. sl+ta I P. >' ,-,,, n-"*, B*r/t, 15t|7{ I ccnrlyrhrr rric p(rturitrNci,l rh.sork,ir whFhrhis Fnn[ is rinkd,I \hnll nor .n!,]n, any Frson rn) nBnns r, n\&,h.!1 r \uhr.t r) rhc lor tLr( .on{r'nsri{ hw\.f C-slituni.- un, Jar( rhlrill \buld hcr.nr subFci t, rla $orkc6' .oqrn$r o. torivob ot Sc.rbn \7lxr ol ih. bhn Gxk. | \tu||. fonhrir h (an ly q [h thqn,rni]n\ NARNIN(i l'rilur r' r.& *orkcr\ c.nq{trsri,r $lunsc i\ unlne,nl. a l shxll \th,..r ai dntlk,to 1,, .rininrl l*Mhi.s rtrd .ier nmr up r! om l$fltr.d trbuenJ ddlnrr tsloo.uDr. in eldilhn ro llE d of .oqrnqriotr dmacr f,r Fovil.J lor rhc S.urtr)n l(176ol rhc Llhr C,\l(, inrcrc{ anl urlorcy \lic\ r,.,., zltjl Ill;clAlAna! I lrrcby!!ltExnlcr Fnulryol Frjury rld I n li..n{rl u6dcr pmvtion o, chllra I (corlmRin8 wirh Sar i'n ?fin I ol l)ivisi,n -l ol irE BosEs! rtrd Pnrcsronr CflL. {d dy lt.N is i. lol lilR dd cffdr laoL-^Y LI '7 L-( ) go,$rru(frxir}lirmi.AlilNqr I h.rhy rflnfl undcr rn0lryol tvjury lhal rlrcr is n.on{d.ri{nr Lndinsrscmy ft rhc Fcrtnn' rc ofrhc *orl t! shrh rhis lctinir is AS:LIJANLIEC!.AAANON I lritary,llim okhr l.n,lry or Frj ry .ic oi rt roll,wing il$hr{'ions: Dcnrrirnn PcrmitsAs&nos Nri icdion Fqlsll R.rulnrion\ (Tirlc.l0, Pad6r R.quftd Gkr ol ldxiltdbn _l (cnrty rhnr lh. f.ltcd E8lb'nfls elrdin! !{Ellos R'Dvrl rrc ml q{'li.!tilc 10 rhr\ nsFr \(cnrryrhr Ihlcr.!drh'\ rnr Hrtr,n r,n {,rcrh{ odnumrindsr .Lir\Ebtr(toh{rrlmqcm.lurD stsh nrnL' cdnn,Fnylorin\Fdi ,ll!qc\ , A,rcur "r ^s6r srEdru* F V P.tulr(mrpri ,: g^*\ L{ fir. rlninil',r 1\.orlrl l nE.. r,ronqnr_r hrll ('ir!rRi(i)unty nl hcr.by lurho.rc qr.rnrariws ol rhis ( ny uxl Counrl kr 6rd qnn rh. "a421 Set Backs Forms/Steel/Holdowns UFER Ground SLAB Floor Subf loor/VenVl nsulation Roof Sheathinq Shear Wall Framing lnsulation/Energy Drywall Ext./lnt. Lath Brown Coat Itrlasonry Pool Fence T-Bar Handicap Req Deputy Final Beport Engineer Final Report Flgo-d Jone Certif ,lt It L)ffiKvt*1(w cfiiI>t LYk\dlh /I ) FINAL 3ltAtt A{\4)IM<2V\t' ICertif icate of Occupancy Notes, Bemarks, Etc Hev.08.07.2015 Erection Pads U / -zt ( r{{trd (ti. :rlr7. C^ (- r I (',.1n. N,,.i. SouthWest Solar Inc. u Owner's Letter of Authorization PROPERTY OWNER: Name: Address:7q( ^r- ,NEvu ?Ln(E City , SAzc.tt tu/n state: CA- zip code +q* P ho ne: To whom it may concern, t,Lrv D?ft{k , authorize Southwest Sun Solar , lnc. to act on my behalf as the active contractor in permitting, installing, and all manners pertaining to my Homeowner's association architectural application (when applicable), Sincerely, Printed Name Southwest Sun SolaI hc. 13752 Hatbor Blvd., Gaden Grovc CA 92843 l3l0 Tully Rd. Suite I 15, San Jose CA 95 I22 q l>o ^o srsnature q-J ;;-l- *,,SANTA NA-'hffi Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-s800 www.santa-ana.org RESIDENTIAL PHOTOVOLTAIC CHECKLIST soL-01 cBc 2013 Solar Photovoltaic (PV) Checklist for Oetached SINGLE FAMILY RESIOENCES Only lnstructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be atlached to each of TWO sets of plans, of minimum 1 1' x 17" size. lf answerinq NO to anv of the questions, Dlan check shall be iequired. Proiect Address:745 W ASTER PL, SANTA ANA, CA 92706 Contractor Company Name: Conlractor License Numbet: SOUTHWEST SUN SOLAR, INC 1004667 1 YES NO E tr Are the following applicable to the proposed proiect? Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.1,1 of the Califomia Fire Code, and is this shown on the roof plan? Will the PV system be installed on a roof having only one roofing layer with no overlays? Will the PV anay be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? Will the PV system weigh maximum 4 pounds per square feet or less? Will the PV system be installed where the modules do nol overhang any roof edges (such as eaves, gabled ends, ridges and hips)? Will the PV system be installed with a space of 2" minimum to 10" maximum between the undeBide of modules and the surface of the roof? Will the PV system be installed without using any ballast system or counter-weight system? Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizonlal spacing shown on the plans? Will the minimum 5/16'' lag screws be installed with a minimum of 2-1l2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? Are ALL the slructural pages of the plans WET stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturefs PV support information.) ./ 4 2 6 7 8tr Etr Eltr Etr Ettr Etr 8 Etr e. Eltr '10 Etr I certify under penalty of perjury under the laws of the State of Print Name: l\re Signature: phone Number: 714 582 3909 Date California that the l. above i 'r j Email Address Rev:8/1712015 PERMTT@SOUTHWESTSUNSOLAR.COM a/