HomeMy WebLinkAbout1429 S Garnsey St - Plan (2)REV SHEET NAME SHEET SIZE SHEET NUMBER EL V I S M A R T I N E Z RE S I D E N C E 14 2 9 S G A R N S E Y S T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:05/05/2025 DRAWN BY ESR MONA LEE SOLAR PROJECT DATA GENERAL NOTES VICINITY MAP SHEET INDEX CODE REFERENCES PROJECT ADDRESS 1429 S GARNSEY ST, SANTA ANA, CA 92707 OWNER:ELVIS MARTINEZ SCOPE: HOUSE PHOTO COVER SHEET PHOTOVOLTAIC ROOF MOUNT SYSTEM 14 MODULES-ROOF MOUNTED - 5.670 KW DC, 5.700 KW AC AND 5.150 KW CEC AC 1429 S GARNSEY ST, SANTA ANA, CA 92707 PV-1 COVER SHEET PV-2 PLOT PLAN WITH ROOF PLAN PV-3 ROOF PLAN & MODULES PV-4 ELECTRICAL PLAN PV-4A ELEVATION PLAN PV-5 ATTACHMENT DETAIL PV-6 ELECTRICAL LINE DIAGRAM PV-7 WIRING CALCULATION PV-7.1 LOAD CALCULATION PV-8 LABELS PV-9 PLACARD PV-10 OPTIMIZER CHART PV-11+EQUIPMENT SPECIFICATIONS PV-1 DESIGNER:ESR PARCEL ID:01313207 PROJECT TO COMPLY WITH THE FOLLOWING: 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA GREEN BUILDING CODE (CGBC) 2022 CALIFORNIA ENERGY CONSERVATION CODE(CEC) 2022 CALIFORNIA RESIDENTIAL CODE(CRC) 2022 CALIFORNIA FIRE CODE (CFC) ASCE 7-16 AUTHORITIES HAVING JURISDICTION: BUILDING: CITY OF SANTA ANA ZONING: CITY OF SANTA ANA UTILITY: SCE 1. ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE WARRANTED. 2. THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH ARTICLE 690 OF THE CEC 2022. 3. THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION. 4. ALL CONDUCTORS OF A CIRCUIT, INCLUDING THE EGC, MUST BE INSTALLED IN THE SAME RACEWAY, OR CABLE, OR OTHERWISE RUN WITH THE PV ARRAY CIRCUIT CONDUCTORS WHEN THEY LEAVE THE VICINITY OF THE PV ARRAY. 5. WHERE METALLIC CONDUIT CONTAINING DC CONDUCTORS IS USED INSIDE THE BUILDING, IT SHALL BE IDENTIFIED AS "CAUTION: SOLAR CIRCUIT" EVERY 10FT. 6. HEIGHT OF THE AC DISCONNECT SHALL NOT EXCEED 6'-7" PER CEC CODE 240.24. 7. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH CEC 2022 690.47 AND 250.50 THROUGH 60 AND 250-166 SHALL BE PROVIDED. PER CEC GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE OR INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT. GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGER THAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 8. PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED NON-COMBUSTIBLE. 9. PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING. MECHANICAL, OR BUILDING ROOF VENTS. 10. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF THE ROOF SURFACE. 11. ALL SINAGE TO BE PLACED IN ACCORDANCE WITH THE LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SINAGE WILL BE INSTALLED AS REQUIRED BY THE CEC AND AHJ. 12. INVERTER(S) USED IN UNGROUNDED SYSTEM SHALL BE UL 1741 LISTED. 13. THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE PERFORMED ONLY BY QUALIFIED PERSONS [CEC 690.4(C)] 14. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED (OR BETTER), INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. 15. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH CEC ARTICLE 250. 16. SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH CEC 690.41. 17. PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION IN ACCORDANCE WITH CEC 690.12 18. DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LOCATION WITHIN THE PV SYSTEM EQUIPMENT OR A MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [CEC 690.13(A)] 19. ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH CEC 690.31 20. WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER CEC 110.26(A)(1), 110.26(A)(2) AND 110.26(A)(3). 21. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED & IDENTIFIED IN ACCORDANCE WITH UL1703 22. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER CEC. 5.670 KW DC ROOF MOUNT SOLAR PV SYSTEM WITH 14 JA SOLAR: JAM54S31 405/MR 405W MONO MODULES WITH 14 SOLAREDGE:S440-5NC4ARS POWER OPTIMIZERS WITH 02 SOLAREDGE TECHNOLOGIES LTD. SE5700H-USMNBL75 (240V) INVERTER 02 SOLAREDGE TECHNOLOGIES LTD. ENERGY BANK 10 KWH BATTERY BAT-10K1P WITH UPGRADE METER MAIN COMBO TO 200A RATED BUS WITH 200A MAIN BREAKER EXP 3/31/2026 Jeffrey Onorati Digitally signed by Jeffrey Onorati Date: 2025.06.09 11:26:47 -07'00' The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. Bldg# 101124146 Elec# 20186228 Approval: Elec - MSmith 50 ' - 7 " 139'-1" 139'-1" 50 ' - 7 " MSPUMBLP INV ACD BUI BAT BAT 1 PLOT PLAN WITH ROOF PLAN SCALE: 3/32" = 1'-0"PV-2 REV SHEET NAME SHEET SIZE SHEET NUMBER EL V I S M A R T I N E Z RE S I D E N C E 14 2 9 S G A R N S E Y S T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:05/05/2025 DRAWN BY ESR MONA LEE SOLAR PROJECT DESCRIPTION: 14 X JA SOLAR: JAM54S31 405/MR 405W MONO MODULES ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES DC SYSTEM SIZE: 5.670 KW DC AC SYSTEM SIZE: 5.700 KW AC AND 5.150 KW CEC AC PV-2 PLOT PLAN WITH ROOF PLAN ELECTRICAL POWER SOURCE DISCONNECT SCHEDULE ENERGY SOURCE UTILITY SERVICE PV SYSTEM DISCONNECT # OF 1 OF 2 2 OF 2 DISCONNECTION OPERATION/EQUIPMENT/DEVICE UTILITY - 200A MAIN BREAKER 100A UTILITY NON-FUSED AC DISCONNECT ROOF ACCESS POINT ROOF ARRAY AREA #1:- 294.14 SQ FT. EQUIPMENT SUMMARY 14 JA SOLAR: JAM54S31 405/MR 405W MONO MODULES 14 SOLAREDGE:S440-5NC4ARS POWER OPTIMIZERS WITH 02 SOLAREDGE TECHNOLOGIES LTD. SE5700H-USMNBL75 (240V) INVERTER 02 BAT-10K1P ENERGY BANK 10 KWH BATTERY ROOF #1 (14) JA SOLAR: JAM54S31 405/MR 405W MONO MODULES WITH SOLAREDGE:S440-5NC4ARS POWER OPTIMIZERS (E) AC UNIT (N) SOLAREDGE TECHNOLOGIES LTD. SE5700H-USMNBL75 (240V) INVERTER (OUTSIDE) (N) 02 SOLAREDGE TECHNOLOGIES LTD. ENERGY BANK 10 KWH BATTERY BAT-10K1P (OUTSIDE) (N) VISIBLE, LOCKABLE, LABELED NON-FUSED PV AC DISCONNECT(LOCATED WITHIN 10' OF UTILITY METER) (OUTSIDE)(2 OF 2) (N) BACKUP LOAD PANEL (OUTSIDE) (E) TREES S G A R N S E Y S T (E) DETACHED STRUCTURE(TYP.) PROPERTY LINE PR O P E R T Y L I N E PROPERTY LINE PR O P E R T Y L I N E EXISTING DRIVEWAY 1-STORY HOUSE (N) SOLAREDGE BACKUP INTERFACE BI-NUSGN-01 (OUTSIDE) (N) UTILITY METER/MAIN COMBO(OUTSIDE)(1 OF 2) NOTE: 1. NEW MSP WILL INSTALLATED IN THE SAME LOCATION AS THAT OF EXISTING MSP. EXP 3/31/2026 7" 26'-4" 3'-2" MSPUMBLP INV ACD BUI BAT BAT MODULE TYPE, DIMENSIONS & WEIGHT 1 ROOF PLAN & MODULES PV-3 SCALE: 3/16" = 1'-0" ROOF PLAN & MODULES REV SHEET NAME SHEET SIZE SHEET NUMBER EL V I S M A R T I N E Z RE S I D E N C E 14 2 9 S G A R N S E Y S T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:05/05/2025 DRAWN BY ESR MONA LEE SOLAR NUMBER OF MODULES = 14 MODULES MODULE TYPE = JA SOLAR: JAM54S31 405/MR 405W MONO MODULES MODULE WEIGHT = 47.39 LBS / 21.5 KG. MODULE DIMENSIONS = 67.79" x 44.64" = 21.01 SF PV-3 JA SOLAR: JAM54S31 405/MR 405W MONO MODULES 67 . 7 9 " 44.64" ARRAY AREA & ROOF AREA CALC'S ROOF # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 14 294.14 870.22 34 TOTAL 14 294.14 1513.35 19 (35) EVEREST K2 FLEX FOOT ATTACHMENTS (N) EVEREST K2 SYSTEMS CROSSRAIL 44-X ROOF DESCRIPTION ROOF TYPE ROLLED COMP ROOF ROOF PITCH AZIMUTH RAFTER SIZE RAFTER SPACING #1 5°180°2"X4"24" LEGEND - VENT, ATTIC FAN (ROOF OBSTRUCTION) - ROOF ATTACHMENT - RAFTER INV ACD - AC DISCONNECT - UTILITY METER/ MAIN COMBO UM MSP BUI - SOLAREDGE BACKUP INTERFACE BAT - SOLAREDGE BATTERY BLP - BACKUP LOAD PANEL - SOLAREDGE INVERTER ROOF ACCESS POINT ROOF #1 (14) JA SOLAR: JAM54S31 405/MR 405W MONO MODULES WITH SOLAREDGE:S440-5NC4ARS POWER OPTIMIZERS (E) AC UNIT (N) VISIBLE, LOCKABLE, LABELED NON-FUSED PV AC DISCONNECT (LOCATED WITHIN 10' OF UTILITY METER) (OUTSIDE)(2 OF 2) (N) BACKUP LOAD PANEL (OUTSIDE) (N) SOLAREDGE TECHNOLOGIES LTD. SE5700H-USMNBL75 (240V) INVERTER (OUTSIDE) (N) 02 SOLAREDGE TECHNOLOGIES LTD. ENERGY BANK 10 KWH BATTERY BAT-10K1P (OUTSIDE) (N) SOLAREDGE BACKUP INTERFACE BI-NUSGN-01 (OUTSIDE) 36" FIRE SETBACK 36 " F I R E S E T B A C K ROOF #1 PITCH - 5 AZIM. - 180 (N) UTILITY METER/MAIN COMBO (OUTSIDE)(1 of 2) ELECTRICAL POWER SOURCE DISCONNECT SCHEDULE ENERGY SOURCE UTILITY SERVICE PV SYSTEM DISCONNECT # OF 1 OF 2 2 OF 2 DISCONNECTION OPERATION/EQUIPMENT/DEVICE UTILITY - 200A MAIN BREAKER 100A UTILITY NON-FUSED AC DISCONNECT NOTE: 1. NEW MSP WILL INSTALLATED IN THE SAME LOCATION AS THAT OF EXISTING MSP. EXP 3/31/2026 MSPUMBLP INV ACD BUI BAT BAT JB 1 ELECTRICAL PLAN PV-4 SCALE: 3/16" = 1'-0" ELECTRICAL PLAN REV SHEET NAME SHEET SIZE SHEET NUMBER EL V I S M A R T I N E Z RE S I D E N C E 14 2 9 S G A R N S E Y S T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:05/05/2025 DRAWN BY ESR MONA LEE SOLAR PV-4 BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULES 14 JA SOLAR: JAM54S31 405/MR 405W MONO MODULES INVERTER 02 SOLAREDGE TECHNOLOGIES LTD. SE5700H-USMNBL75 (240V) INVERTER OPTIMIZERS 14 SOLAREDGE:S440-5NC4ARS POWER OPTIMIZERS JUNCTION BOXES 1 6"X6"X4" UL LISTED, STEEL WATER TIGHT NEMA TYPE 3R, UL LISTED RAILS 7 EVEREST K2 SYSTEMS CROSSRAIL 44-X, 166" SPLICE 2 SPLICE KIT MODULE CLAMPS 20 MID MODULE CLAMPS END CLAMPS 16 END CLAMPS ATTACHMENTS 35 EVEREST K2 FLEX FOOT ATTACHMENTS BATTERY 02 SOLAREDGE TECHNOLOGIES LTD. ENERGY BANK 10 KWH BATTERY BAT-10K1P BACKUP INTEFACE 01 SOLAREDGE BACKUP INTERFACE BI-NUSGN-01 200A RATED, 240V NEMA 3R, UL LISTED STRING #1 (14 MODULES) (N) JUNCTION BOX (14) SOLAREDGE:S440-5NC4ARS POWER OPTIMIZERS - SOLAREDGE:S440-5NC4ARS POWER OPTIMIZERS LEGEND INV ACD - AC DISCONNECT UM BUI - SOLAREDGE BACKUP INTERFACE BAT - SOLAREDGE BATTERY BLP - BACKUP LOAD PANEL - CONDUIT - JUNCTION BOXJB - UTILITY METER/ MAIN COMBO - SOLAREDGE INVERTER MSP (N) CONDUIT STRING #1 STRING LEGENDS ROOF #1 (14) JA SOLAR: JAM54S31 405/MR 405W MONO MODULES WITH SOLAREDGE:S440-5NC4ARS POWER OPTIMIZERS (N) VISIBLE, LOCKABLE, LABELED NON-FUSED PV AC DISCONNECT (LOCATED WITHIN 10' OF UTILITY METER) (OUTSIDE)(2 OF 2) (N) BACKUP LOAD PANEL (OUTSIDE) (N) SOLAREDGE TECHNOLOGIES LTD. SE5700H-USMNBL75 (240V) INVERTER (OUTSIDE) (N) 02 SOLAREDGE TECHNOLOGIES LTD. ENERGY BANK 10 KWH BATTERY BAT-10K1P (OUTSIDE) (N) SOLAREDGE BACKUP INTERFACE BI-NUSGN-01 (OUTSIDE) S G A R N S E Y S T (N) UTILITY METER/MAIN COMBO (OUTSIDE)(1 of 2) ELECTRICAL POWER SOURCE DISCONNECT SCHEDULE ENERGY SOURCE UTILITY SERVICE DISCONNECT # OF 1 OF 2 DISCONNECTION OPERATION/EQUIPMENT/DEVICE UTILITY - 200A MAIN BREAKER PV SYSTEM 2 OF 2 100A UTILITY AC DISCONNECT NOTE: 1. NEW MSP WILL INSTALLATED IN THE SAME LOCATION AS THAT OF EXISTING MSP. David C Hernandez Digitally signed by David C Hernandez Date: 2025.06.09 16:09:34 -04'00' MSPUMBLP INV ACD BUI BAT BAT JB 1 ELECTRICAL PLAN PV-4 SCALE: 3/16" = 1'-0" ELECTRICAL PLAN REV SHEET NAME SHEET SIZE SHEET NUMBER EL V I S M A R T I N E Z RE S I D E N C E 14 2 9 S G A R N S E Y S T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:05/05/2025 DRAWN BY ESR MONA LEE SOLAR PV-4 BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULES 14 JA SOLAR: JAM54S31 405/MR 405W MONO MODULES INVERTER 02 SOLAREDGE TECHNOLOGIES LTD. SE5700H-USMNBL75 (240V) INVERTER OPTIMIZERS 14 SOLAREDGE:S440-5NC4ARS POWER OPTIMIZERS JUNCTION BOXES 1 6"X6"X4" UL LISTED, STEEL WATER TIGHT NEMA TYPE 3R, UL LISTED RAILS 7 EVEREST K2 SYSTEMS CROSSRAIL 44-X, 166" SPLICE 2 SPLICE KIT MODULE CLAMPS 20 MID MODULE CLAMPS END CLAMPS 16 END CLAMPS ATTACHMENTS 35 EVEREST K2 FLEX FOOT ATTACHMENTS BATTERY 02 SOLAREDGE TECHNOLOGIES LTD. ENERGY BANK 10 KWH BATTERY BAT-10K1P BACKUP INTEFACE 01 SOLAREDGE BACKUP INTERFACE BI-NUSGN-01 200A RATED, 240V NEMA 3R, UL LISTED STRING #1 (14 MODULES) (N) JUNCTION BOX (14) SOLAREDGE:S440-5NC4ARS POWER OPTIMIZERS - SOLAREDGE:S440-5NC4ARS POWER OPTIMIZERS LEGEND INV ACD - AC DISCONNECT UM BUI - SOLAREDGE BACKUP INTERFACE BAT - SOLAREDGE BATTERY BLP - BACKUP LOAD PANEL - CONDUIT - JUNCTION BOXJB - UTILITY METER/ MAIN COMBO - SOLAREDGE INVERTER MSP (N) CONDUIT STRING #1 STRING LEGENDS ROOF #1 (14) JA SOLAR: JAM54S31 405/MR 405W MONO MODULES WITH SOLAREDGE:S440-5NC4ARS POWER OPTIMIZERS (N) VISIBLE, LOCKABLE, LABELED NON-FUSED PV AC DISCONNECT (LOCATED WITHIN 10' OF UTILITY METER) (OUTSIDE)(2 OF 2) (N) BACKUP LOAD PANEL (OUTSIDE) (N) SOLAREDGE TECHNOLOGIES LTD. SE5700H-USMNBL75 (240V) INVERTER (OUTSIDE) (N) 02 SOLAREDGE TECHNOLOGIES LTD. ENERGY BANK 10 KWH BATTERY BAT-10K1P (OUTSIDE) (N) SOLAREDGE BACKUP INTERFACE BI-NUSGN-01 (OUTSIDE) S G A R N S E Y S T (E) UTILITY METER/MAIN COMBO (OUTSIDE)(1 of 2) ELECTRICAL POWER SOURCE DISCONNECT SCHEDULE ENERGY SOURCE UTILITY SERVICE DISCONNECT # OF 1 OF 2 DISCONNECTION OPERATION/EQUIPMENT/DEVICE UTILITY - 100A MAIN BREAKER PV SYSTEM 2 OF 2 100A UTILITY AC DISCONNECT David C Hernandez Digitally signed by David C Hernandez Date: 2025.05.20 16:05:14 -04'00' REV SHEET NAME SHEET SIZE SHEET NUMBER EL V I S M A R T I N E Z RE S I D E N C E 14 2 9 S G A R N S E Y S T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:05/05/2025 DRAWN BY ESR MONA LEE SOLAR D08/05/2025AHJ COMMENT LOAD CALCULATION BACKUP PANEL LOAD CALCULATION D Green Building Engineer #832 REV SHEET NAME SHEET SIZE SHEET NUMBER EL V I S M A R T I N E Z RE S I D E N C E 14 2 9 S G A R N S E Y S T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:05/05/2025 DRAWN BY ESR MONA LEE SOLAR ATTACHMENT DETAIL PV-5 1 ATTACHMENT DETAIL (SIDE VIEW) PV-5 2 ATTACHMENT DETAIL (ENLARGED VIEW) PV-5 SCALE: N.T.S. SCALE: N.T.S. 6" SEE (2/PV-5) FOR ENLARGED VIEW PV MODULE (E) ROLLED COMP ROOF CHANNEL NUT PV MODULE GROUNDING END/MID CLAMP EVEREST K2 SYSTEMS CROSSRAIL 44-X (E) ROLLED COMP ROOF (4) M5 X 60MM DIN 571, METRIC, HEX HEAD LAG SCREW BOLTS, A2 STAINLESS STEEL (N) EVEREST K2 SYSTEMS FLEX FOOT ATTACHMENTS EXP 3/31/2026 SOLAREDGE BACKUP INTERFACE BI-NUSGN-01 200A RATED, 240V NEMA 3R, UL LISTED CONTROLLER G N (E) BACKUP LOAD PANEL GE, 125A RATED, 120/240V 30A/2P N G AUTO TRANSFORMER AUTO TRANSFER RELAY L1 L2 N G 3 (N) SOLAR BREAKER L1 L2 N G (N) BACKUP BREAKER 240V, 100A/2P 1 2 G L1 L2 (14) JA SOLAR:JAM54S31 405/MR 405W MODULES -+ -++ -+ +++--- 2 -+ - 1 3 = = = = = = = = = = STRING #1 13 14 SOLAREDGE POWER OPTIMIZERS S440 RATED DC INPUT POWER - 440WATTS MAXIMUM INPUT VOLTAGE - 60 VDC MPPT RANGE - 8 TO 60 VDC MAXIMUM SHORT CIRCUIT CURRENT - 14.5 ADC MAXIMUM OUTPUT CURRENT - 15 ADC STRING LIMITATIONS - 8 TO 25 OPTIMIZERS, 5700 WATTS STC PER STRING MAXIMUM JUNCTION BOX, 600V, NEMA 3R, UL LISTED LOAD GN PV DISCONNECT(2 OF 2) 240V, 1ɸ, 3W 30A RATED NEMA 3R (EATON DG221URB) VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 10' OF UTILITY METER LINE 4 SOLAREDGE: SE5700H-US HOME HUB INVERTER OUTPUT: 240 VAC, 24A 99% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT 3A L1 L2 G 10 kWh SOLAREDGE ENERGY BANK NOTE: ANY MULTIWIRE BRANCH CIRCUITS RELOCATED ARE TO BE IDENTIFIED, GROUPED, AND EQUIPPED WITH A 2- POLE OCPD BREAKER PER CEC 210.4(B,D). "NOTE: ALL LOADS ARE EXISTING AND MOVED FROM MAIN PANEL" NOTE: IF THE RELOCATED LOADS EXTEND MORE THAN 6 FEET, AFCI PROTECTION APPLIES PER 2019 CEC 210.12 LOAD SIDE INTERCONCECTION AT MAIN PANEL PER ART. 705.12 L1 L2 G N (N) MAIN BREAKER TO HOUSE 240 V, 200A/2P (1 OF 2) N G NL2L1 TO UTILITY GRID M BI-DIRECTIONAL UTILITY METER 120/240V, 1ɸ, 3-W (N) MAIN SERVICE PANEL, 200A RATED, 240V L1 L2 G 10 kWh SOLAREDGE ENERGY BANK 4 INTERCONNECTION REF 705.12 BACKFEED 100A/2P (E) BONDING JUMPER PER NEC 250.92(A)(2) NEW GROUNDING ELECRODES & NEW AUXILLARY GROUNDING ELECTRODE (6 FEET APART). REQ. 5/8" DIA. GROUNDING ROD WITH 8' MIN. EMBEDMENT MIN 6" BETWEEN ELECTRODES BOND COLD WATER & GAS LINE CEC 250.104 (A) & (B) NOTE: 1. UPGRADE METER MAIN COMBO TO 200A RATED BUS WITH 200A MAIN BREAKER. 2. NEW MSP WILL INSTALLATED IN THE SAME LOCATION AS THAT OF EXISTING MSP. L1 L2 N G 3 REV SHEET NAME SHEET SIZE SHEET NUMBER EL V I S M A R T I N E Z RE S I D E N C E 14 2 9 S G A R N S E Y S T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:05/05/2025 DRAWN BY ESR MONA LEE SOLAR D08/05/2025AHJ COMMENT ELECTRICAL LINE DIAGRAM 1 ELECTRICAL LINE DIAGRAM PV-6 SCALE: NTS PV-6 INSTALLER / ELECTRICIAN NOTE: EC IS TO MEASURE VOLTAGE BEFORE STARTING WORK. IF RESULT IS ANY OTHER VOLTAGE MEASURED THAN 120/240V IS OBSERVED, DO NOT PROCEED. CONTACT ENGINEER. GROUNDING & GENERAL NOTES: 1. A SECOND FACILITY GROUNDING ELECTRODE IS NOT REQUIRED PER [CEC 690.47(C)(3)] 2. PV INVERTER IS UNGROUNDED, TRANSFORMER-LESS TYPE. 3. DC GEC AND AC EGC TO REMAIN UNSPLICED, OR SPLICED TO EXISTING ELECTRODE 4. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. 5. JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - JUNCTION BOX DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 6. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER AC DISCONNECTING MEANS IS LOCATED WITHIN 5' OF SERVICE DISCONNECT. 7. RACEWAYS AND CABLES EXPOSED TO SUNLIGHT ON ROOFTOPS SHOULD BE INSTALLED MORE THAN 7/8" ABOVE THE ROOF USING CONDUIT SUPPORTS. 8. ALL NEW SERVICE INSTALLATIONS AND REPLACEMENTS REQUIRE A SURGE-PROTECTIVE DEVICE (SPD) IN ACCORDANCE WITH [CEC 230.67]. THE SPD SHALL BE TYPE 1 OR TYPE 2 AND IS REQUIRED TO BE AN INTEGRAL PART OF THE SERVICE EQUIPMENT OR LOCATED IMMEDIATELY ADJACENT THERETO. INTERCONNECTION NOTES: 1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE DETERMINED IN ACCORDANCE WITH [CEC 705.12], AND [CEC 690.64]. 2. GROUND FAULT PROTECTION IN ACCORDANCE WITH [CEC 215.9], [CEC 230.95] AND [CEC 690.5] 3. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. 4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER. DISCONNECT NOTES: 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH RACKING NOTES: 1. BOND EVERY OTHER RAIL WITH #6 BARE COPPER QTY CONDUCTOR INFORMATION CONDUIT TYPE CONDUIT SIZE (2) N/A N/A (1)1 BARE COPPER IN FREE AIR PV WIRE/USE-2 #6AWG - #10AWG - (2)#10AWG -CU,THWN-2 EMT OR LFMC 3/4"(1)#8AWG -CU,THWN-2 GND2 #10AWG - #10AWG - #10AWG - (2)CU,THWN-2 (1)CU,THWN-2 N (1)CU,THWN-2 GND EMT,LFMC OR PVC3 3/4" #3AWG - #3AWG - #8AWG - (2)CU,THWN-2 (1)CU,THWN-2 N (1)CU,THWN-2 GND EMT,LFMC OR PVC 1''4 DC SYSTEM SIZE: 5.670 KW DC AC SYSTEM SIZE: 5.700 KW AC & 5.150 KW CEC AC 14 JA SOLAR: JAM54S31 405/MR 405W MONO MODULES WITH 14 SOLAREDGE:S440-5NC4ARS POWER OPTIMIZERS WITH 01 SOLAREDGE TECHNOLOGIES LTD. SE5700H-USMNBL75 (240V) INVERTER 02 SOLAREDGE TECHNOLOGIES LTD. ENERGY BANK 10 KWH BATTERY BAT-10K1P (01) STRING OF 14 MODULES ARE CONNECTED IN SERIES NOTE- RELOCATE ALL LOADS FROM MAIN PANEL TO BACKUP LOAD PANEL ELECTRICAL POWER SOURCE DISCONNECT SCHEDULE ENERGY SOURCE UTILITY SERVICE PV SYSTEM DISCONNECT # OF 1 OF 2 2 OF 2 DISCONNECTION OPERATION/EQUIPMENT/DEVICE UTILITY - 200A MAIN BREAKER 30A UTILITY NON-FUSED AC DISCONNECT D E #8AWG - #10AWG - (2)CU,THWN-2 (1)CU,THWN-2 GND EMT,LFMC OR PVC 3/4''3A Green Building Engineer #832 REV SHEET NAME SHEET SIZE SHEET NUMBER EL V I S M A R T I N E Z RE S I D E N C E 14 2 9 S G A R N S E Y S T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:05/05/2025 DRAWN BY ESR MONA LEE SOLAR WIRING CALCULATIONS PV-7 PERCENT OF VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT .80 4-6 .70 7-9 .50 10-20 SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL #JA SOLAR: JAM54S31 405/MR 405W PV MODULES VMP 31.45V IMP 12.98A VOC 37.23V ISC 13.87A TEMP. COEFF. VOC -0.275%/°C MODULE DIMENSION 67.79"L x 44.64"W x 1.18"D (In Inch) AMBIENT TEMPERATURE SPECS RECORD LOW TEMP 2° AMBIENT TEMP (HIGH TEMP 2%)39° MODULE TEMPERATURE COEFFICIENT OF Voc -0.265%/°C ELECTRICAL NOTES 1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH CEC 110.26. 5.DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.WHERE SIZES OF JUNCTION BOX, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.TEMPERATURE RATINGS OF ALL CONDUCTORS, TERMINATIONS, BREAKERS, OR OTHER DEVICES ASSOCIATED WITH THE SOLAR PV SYSTEM SHALL BE RATED FOR AT LEAST 75 DEGREE C. INVERTER SPECIFICATIONS MANUFACTURER / MODEL #SOLAREDGE TECHNOLOGIES LTD. SE5700H-USMNBL75 (240V) INVERTER NOMINAL AC POWER 5.700 kW NOMINAL OUTPUT VOLTAGE 240 VAC NOMINAL OUTPUT CURRENT 24A REV SHEET NAME SHEET SIZE SHEET NUMBER EL V I S M A R T I N E Z RE S I D E N C E 14 2 9 S G A R N S E Y S T , SA N T A A N A , C A 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:05/05/2025 DRAWN BY ESR MONA LEE SOLAR LABELS PV-8 LABEL LOCATION: MAIN SERVICE PANEL SUBPANEL AC DISCONNECT CODE REF: CEC 690.13(B) TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING! ELECTRIC SHOCK HAZARD LABEL LOCATION: AC DISCONNECT COMBINER CODE REF: CEC 690.13(B) LABEL- 1: LABEL LOCATION: MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK-FED) SUBPANEL (ONLY IF SOLAR IS BACK-FED) CODE REF: CEC 705.12(B)(2)(c) LABEL- 2: SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION: AC DISCONNECT CODE REF: CEC 690.56(C)(2) LABEL- 4: WARNING POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE ! WARNING: PHOTOVOLTAIC POWER SOURCE LABEL- 5: LABEL LOCATION: MAIN SERVICE PANEL CODE REF: CFC 605.11.3.1(1) & CEC 690.56(C)(1)(a) LABEL- 3: PV SYSTEM DISCONNECT FOR UTILITY OPERATION LABEL- 8: LABEL LOCATION: AC DISCONNECT CODE REF: CEC 706.15(C) LABEL LOCATION: EMT/CONDUIT RACEWAY SOLADECK / JUNCTION BOX CODE REF: CEC 690.31 (G)(3)(4) !WARNING TRI POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM THIRD SOURCE IS ESS SYSTEM LABEL LOCATION: PRODUCTION METER UTILITY METER MAIN SERVICE PANEL SUBPANEL CODE REF: CEC 705.12(C) & CEC 690.59 LABEL- 7: MAXIMUM VOLTAGE MAXIMUM INPUT CURRENT MAXIMUM RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-SC CONVERTER (IF INSTALLED) LABEL- 9: LABEL LOCATION: INVERTER CODE REF: CEC 690.53 480.0 V 30 A LABEL- 6: INVERTER AC DISCONNECT NOMINAL OPERATING AC VOLATGE RATED AC OUTPUT CURRENT 240 V 24.0 A CAUTION :NO ADDITIONAL LOADS TO BE ADDED LABEL- 10: LABEL LOCATION: BACKED UP LOAD PANEL REV SHEET NAME SHEET SIZE SHEET NUMBER EL V I S M A R T I N E Z RE S I D E N C E 14 2 9 S G A R N S E Y S T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:05/05/2025 DRAWN BY ESR MONA LEE SOLAR D08/05/2025AHJ COMMENT LOAD CALCULATION MAIN PANEL LOAD CALCULATION (ALL LOADS)D Green Building Engineer #832 MSPUMACD INV BLP BUI BAT BAT JB REV SHEET NAME SHEET SIZE SHEET NUMBER EL V I S M A R T I N E Z RE S I D E N C E 14 2 9 S G A R N S E Y S T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:05/05/2025 DRAWN BY ESR MONA LEE SOLAR D08/05/2025AHJ COMMENT PLACARD 1429 S GARNSEY ST, SANTA ANA, CA 92707 PV-9 DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: CEC 690.56(A)(B), [CEC 705.10]) LABELING NOTES: 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT CEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2. LABELING REQUIREMENTS BASED ON THE 2022 CEC, OSHA STANDARD 19010.145, ANSI Z535. 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [CEC 110.21] CAUTION: MULTIPLE SOURCES OF POWER (N) PV ARRAY (N) JUNCTION BOX (N) SOLAREDGE INVERTER (N) DISCONNECT (N) BACKUP PANEL S G A R N S E Y S T (E) SOLAREDGE BACKUP INTERFACE BI-NUSGN-01 (OUTSIDE) (N) 02 SOLAREDGE BATTERY (N) METERMAIN COMBO D Green Building Engineer #832 REV SHEET NAME SHEET SIZE SHEET NUMBER EL V I S M A R T I N E Z RE S I D E N C E 14 2 9 S G A R N S E Y S T , SA N T A A N A , C A 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:05/05/2025 DRAWN BY ESR MONA LEE SOLAR OPTIMIZER CHART OPTIMIZER CHART 1-10 2 3 4 11-20 21-30 31-40 41-50 51-60 5 61-70 6 7 8 9 10 1 PV-10 MSP PANEL SCHEDULE (N) BUI BREAKER 2/P-100A BACKUP PANEL SCHEDULE DRYER 1/P-15A LIGHT PLUGS 1/P-15A REFRIGATOR 1/P-20A 1/P-20A 1/P-20A KITCHEN ROOM2 1/P-20A DISPOSAL 1/2-20A 1/P-20A 1/P-20A LIGHT PLUGS A/C BREAKER 2/P-50A REV SHEET NAME SHEET SIZE SHEET NUMBER EL V I S M A R T I N E Z RE S I D E N C E 14 2 9 S G A R N S E Y S T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:05/05/2025 DRAWN BY ESR MONA LEE SOLAR D08/05/2025AHJ COMMENT PANEL SCHEDULE D Green Building Engineer #832 REV SHEET NAME SHEET SIZE SHEET NUMBER EL V I S M A R T I N E Z RE S I D E N C E 14 2 9 S G A R N S E Y S T , SA N T A A N A , C A 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:05/05/2025 DRAWN BY ESR MONA LEE SOLAR EQUIPMENT SPECIFICATION PV-11 REV SHEET NAME SHEET SIZE SHEET NUMBER EL V I S M A R T I N E Z RE S I D E N C E 14 2 9 S G A R N S E Y S T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:05/05/2025 DRAWN BY ESR MONA LEE SOLAR EQUIPMENT SPECIFICATION PV-12 REV SHEET NAME SHEET SIZE SHEET NUMBER EL V I S M A R T I N E Z RE S I D E N C E 14 2 9 S G A R N S E Y S T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:05/05/2025 DRAWN BY ESR MONA LEE SOLAR EQUIPMENT SPECIFICATION PV-13 REV SHEET NAME SHEET SIZE SHEET NUMBER EL V I S M A R T I N E Z RE S I D E N C E 14 2 9 S G A R N S E Y S T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:05/05/2025 DRAWN BY ESR MONA LEE SOLAR EQUIPMENT SPECIFICATION PV-14 REV SHEET NAME SHEET SIZE SHEET NUMBER EL V I S M A R T I N E Z RE S I D E N C E 14 2 9 S G A R N S E Y S T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:05/05/2025 DRAWN BY ESR MONA LEE SOLAR EQUIPMENT SPECIFICATION PV-15 EXP 3/31/2026 REV SHEET NAME SHEET SIZE SHEET NUMBER EL V I S M A R T I N E Z RE S I D E N C E 14 2 9 S G A R N S E Y S T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:05/05/2025 DRAWN BY ESR MONA LEE SOLAR EQUIPMENT SPECIFICATION PV-16 EXP 3/31/2026 REV SHEET NAME SHEET SIZE SHEET NUMBER EL V I S M A R T I N E Z RE S I D E N C E 14 2 9 S G A R N S E Y S T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:05/05/2025 DRAWN BY ESR MONA LEE SOLAR EQUIPMENT SPECIFICATION PV-17 EXP 3/31/2026 REV SHEET NAME SHEET SIZE SHEET NUMBER EL V I S M A R T I N E Z RE S I D E N C E 14 2 9 S G A R N S E Y S T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:05/05/2025 DRAWN BY ESR MONA LEE SOLAR EQUIPMENT SPECIFICATION PV-18 EXP 3/31/2026 REV SHEET NAME SHEET SIZE SHEET NUMBER EL V I S M A R T I N E Z RE S I D E N C E 14 2 9 S G A R N S E Y S T , SA N T A A N A , CA 9 2 7 0 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:05/05/2025 DRAWN BY ESR MONA LEE SOLAR EQUIPMENT SPECIFICATION PV-19 Property Owner Authorization Letter I, Elvis Martinez, hereby grant permission for the installation of a solar system on the property located at 1429 S Garnsey St, Santa Ana, CA 92707. This authorization includes all necessary permits, inspections, and access required for the installation, operation, and maintenance of the solar system. I understand that this solar system installation will involve the placement of solar panels and associated equipment on the property. I acknowledge that I am the legal owner of the property and have the authority to grant permission for this installation. I authorize Monalee Solar, their contractors, employees, or agents to access the property for the purpose of installing, maintaining, repairing, and removing the solar system as needed. I agree to cooperate with Monalee Solar to facilitate the installation process and to ensure the proper functioning of the solar system. I acknowledge that I have reviewed and agreed to the terms and conditions of the solar system installation agreement provided by Monalee Solar I understand that I may be eligible for various incentives, tax credits, or rebates related to the installation of the solar system, and I authorize Monalee Solar to pursue these incentives on my behalf. This authorization is valid until the solar system is removed from the property or until further notice is provided in writing. I understand that I may revoke this authorization at any time by providing written notice to Monalee Solar. Sincerely, Elvis Martinez Docusign Envelope ID: 3853A5EB-BE9A-4482-8F51-A3D3790D44EF Certificate Of Completion Envelope Id: 3853A5EB-BE9A-4482-8F51-A3D3790D44EF Status: Completed Subject: Complete with Docusign: 1429 S Garnsey St Property Owner Authorization Letter.pdf Source Envelope: Document Pages: 1 Signatures: 1 Envelope Originator: Certificate Pages: 5 Initials: 0 Mona Lee AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) , MA 02210 interconnections@monalee.co IP Address: 194.113.66.229 Record Tracking Status: Original 6/3/2025 10:01:46 AM Holder: Mona Lee interconnections@monalee.co Location: DocuSign Signer Events Signature Timestamp Elvis Martinez viceem1@yahoo.com Security Level: Email, Account Authentication (None) Signature Adoption: Drawn on Device Using IP Address: 2600:387:15:541b::b Signed using mobile Sent: 6/3/2025 10:03:13 AM Viewed: 6/4/2025 7:39:51 PM Signed: 6/4/2025 7:39:59 PM Electronic Record and Signature Disclosure: Accepted: 6/4/2025 7:39:51 PM ID: 8550ad3d-b6f3-4af4-a29d-c2786ace3e34 In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Permit Department permits@monalee.co Security Level: Email, Account Authentication (None) Sent: 6/3/2025 10:03:13 AM Electronic Record and Signature Disclosure: Accepted: 4/15/2025 10:44:06 AM ID: 68f72046-a7bc-4233-a2b1-1a10f65623ab Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 6/3/2025 10:03:13 AM Certified Delivered Security Checked 6/4/2025 7:39:51 PM Signing Complete Security Checked 6/4/2025 7:39:59 PM Completed Security Checked 6/4/2025 7:39:59 PM Payment Events Status Timestamps Electronic Record and Signature Disclosure ELECTRONIC RECORD AND SIGNATURE DISCLOSURE From time to time, Jonathan Leung (we, us or Company) may be required by law to provide to you certain written notices or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures electronically through the DocuSign system. Please read the information below carefully and thoroughly, and if you can access this information electronically to your satisfaction and agree to this Electronic Record and Signature Disclosure (ERSD), please confirm your agreement by selecting the check-box next to ‘I agree to use electronic records and signatures’ before clicking ‘CONTINUE’ within the DocuSign system. Getting paper copies At any time, you may request from us a paper copy of any record provided or made available electronically to you by us. You will have the ability to download and print documents we send to you through the DocuSign system during and immediately after the signing session and, if you elect to create a DocuSign account, you may access the documents for a limited period of time (usually 30 days) after such documents are first sent to you. After such time, if you wish for us to send you paper copies of any such documents from our office to you, you will be charged a $0.00 per-page fee. You may request delivery of such paper copies from us by following the procedure described below. Withdrawing your consent If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and disclosures electronically is described below. Consequences of changing your mind If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can complete certain steps in transactions with you and delivering services to you because we will need first to send the required notices or disclosures to you in paper format, and then wait until we receive back from you your acknowledgment of your receipt of such paper notices or disclosures. Further, you will no longer be able to use the DocuSign system to receive required notices and consents electronically from us or to sign electronically documents from us. All notices and disclosures will be sent to you electronically Electronic Record and Signature Disclosure created on: 3/30/2023 4:52:11 PM Parties agreed to: Elvis Martinez, Permit Department Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you through the DocuSign system all required notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the disclosures and notices electronically or in paper format through the paper mail delivery system. If you do not agree with this process, please let us know as described below. Please also see the paragraph immediately above that describes the consequences of your electing not to receive delivery of the notices and disclosures electronically from us. How to contact Jonathan Leung: You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as follows: To contact us by email send messages to: interconnections@monalee.co To advise Jonathan Leung of your new email address To let us know of a change in your email address where we should send notices and disclosures electronically to you, you must send an email message to us at interconnections@monalee.co and in the body of such request you must state: your previous email address, your new email address. We do not require any other information from you to change your email address. If you created a DocuSign account, you may update it with your new email address through your account preferences. To request paper copies from Jonathan Leung To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically, you must send us an email to interconnections@monalee.co and in the body of such request you must state your email address, full name, mailing address, and telephone number. We will bill you for any fees at that time, if any. To withdraw your consent with Jonathan Leung To inform us that you no longer wish to receive future notices and disclosures in electronic format you may: i. decline to sign a document from within your signing session, and on the subsequent page, select the check-box indicating you wish to withdraw your consent, or you may; ii. send us an email to interconnections@monalee.co and in the body of such request you must state your email, full name, mailing address, and telephone number. We do not need any other information from you to withdraw consent.. The consequences of your withdrawing consent for online documents will be that transactions may take a longer time to process.. Required hardware and software The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found here: https://support.docusign.com/guides/signer-guide- signing-system-requirements. Acknowledging your access and consent to receive and sign documents electronically To confirm to us that you can access this information electronically, which will be similar to other electronic notices and disclosures that we will provide to you, please confirm that you have read this ERSD, and (i) that you are able to print on paper or electronically save this ERSD for your future reference and access; or (ii) that you are able to email this ERSD to an email address where you will be able to print on paper or save it for your future reference and access. Further, if you consent to receiving notices and disclosures exclusively in electronic format as described herein, then select the check-box next to ‘I agree to use electronic records and signatures’ before clicking ‘CONTINUE’ within the DocuSign system. By selecting the check-box next to ‘I agree to use electronic records and signatures’, you confirm that:  You can access and read this Electronic Record and Signature Disclosure; and  You can print on paper this Electronic Record and Signature Disclosure, or save or send this Electronic Record and Disclosure to a location where you can print it, for future reference and access; and  Until or unless you notify Jonathan Leung as described above, you consent to receive exclusively through electronic means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you by Jonathan Leung during the course of your relationship with Jonathan Leung. Certificate Of Completion Envelope Id: 3853A5EB-BE9A-4482-8F51-A3D3790D44EF Status: Completed Subject: Complete with Docusign: 1429 S Garnsey St Property Owner Authorization Letter.pdf Source Envelope: Document Pages: 1 Signatures: 1 Envelope Originator: Certificate Pages: 5 Initials: 0 Mona Lee AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) , MA 02210 interconnections@monalee.co IP Address: 194.113.66.229 Record Tracking Status: Original 6/3/2025 10:01:46 AM Holder: Mona Lee interconnections@monalee.co Location: DocuSign Signer Events Signature Timestamp Elvis Martinez viceem1@yahoo.com Security Level: Email, Account Authentication (None) Signature Adoption: Drawn on Device Using IP Address: 2600:387:15:541b::b Signed using mobile Sent: 6/3/2025 10:03:13 AM Viewed: 6/4/2025 7:39:51 PM Signed: 6/4/2025 7:39:59 PM Electronic Record and Signature Disclosure: Accepted: 6/4/2025 7:39:51 PM ID: 8550ad3d-b6f3-4af4-a29d-c2786ace3e34 In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Permit Department permits@monalee.co Security Level: Email, Account Authentication (None) Sent: 6/3/2025 10:03:13 AM Electronic Record and Signature Disclosure: Accepted: 4/15/2025 10:44:06 AM ID: 68f72046-a7bc-4233-a2b1-1a10f65623ab Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 6/3/2025 10:03:13 AM Certified Delivered Security Checked 6/4/2025 7:39:51 PM Signing Complete Security Checked 6/4/2025 7:39:59 PM Completed Security Checked 6/4/2025 7:39:59 PM Payment Events Status Timestamps Electronic Record and Signature Disclosure ELECTRONIC RECORD AND SIGNATURE DISCLOSURE From time to time, Jonathan Leung (we, us or Company) may be required by law to provide to you certain written notices or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures electronically through the DocuSign system. Please read the information below carefully and thoroughly, and if you can access this information electronically to your satisfaction and agree to this Electronic Record and Signature Disclosure (ERSD), please confirm your agreement by selecting the check-box next to ‘I agree to use electronic records and signatures’ before clicking ‘CONTINUE’ within the DocuSign system. Getting paper copies At any time, you may request from us a paper copy of any record provided or made available electronically to you by us. You will have the ability to download and print documents we send to you through the DocuSign system during and immediately after the signing session and, if you elect to create a DocuSign account, you may access the documents for a limited period of time (usually 30 days) after such documents are first sent to you. After such time, if you wish for us to send you paper copies of any such documents from our office to you, you will be charged a $0.00 per-page fee. You may request delivery of such paper copies from us by following the procedure described below. Withdrawing your consent If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and disclosures electronically is described below. Consequences of changing your mind If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can complete certain steps in transactions with you and delivering services to you because we will need first to send the required notices or disclosures to you in paper format, and then wait until we receive back from you your acknowledgment of your receipt of such paper notices or disclosures. Further, you will no longer be able to use the DocuSign system to receive required notices and consents electronically from us or to sign electronically documents from us. All notices and disclosures will be sent to you electronically Electronic Record and Signature Disclosure created on: 3/30/2023 4:52:11 PM Parties agreed to: Elvis Martinez, Permit Department Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you through the DocuSign system all required notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the disclosures and notices electronically or in paper format through the paper mail delivery system. If you do not agree with this process, please let us know as described below. Please also see the paragraph immediately above that describes the consequences of your electing not to receive delivery of the notices and disclosures electronically from us. How to contact Jonathan Leung: You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as follows: To contact us by email send messages to: interconnections@monalee.co To advise Jonathan Leung of your new email address To let us know of a change in your email address where we should send notices and disclosures electronically to you, you must send an email message to us at interconnections@monalee.co and in the body of such request you must state: your previous email address, your new email address. We do not require any other information from you to change your email address. If you created a DocuSign account, you may update it with your new email address through your account preferences. To request paper copies from Jonathan Leung To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically, you must send us an email to interconnections@monalee.co and in the body of such request you must state your email address, full name, mailing address, and telephone number. We will bill you for any fees at that time, if any. To withdraw your consent with Jonathan Leung To inform us that you no longer wish to receive future notices and disclosures in electronic format you may: i. decline to sign a document from within your signing session, and on the subsequent page, select the check-box indicating you wish to withdraw your consent, or you may; ii. send us an email to interconnections@monalee.co and in the body of such request you must state your email, full name, mailing address, and telephone number. We do not need any other information from you to withdraw consent.. The consequences of your withdrawing consent for online documents will be that transactions may take a longer time to process.. Required hardware and software The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found here: https://support.docusign.com/guides/signer-guide- signing-system-requirements. Acknowledging your access and consent to receive and sign documents electronically To confirm to us that you can access this information electronically, which will be similar to other electronic notices and disclosures that we will provide to you, please confirm that you have read this ERSD, and (i) that you are able to print on paper or electronically save this ERSD for your future reference and access; or (ii) that you are able to email this ERSD to an email address where you will be able to print on paper or save it for your future reference and access. Further, if you consent to receiving notices and disclosures exclusively in electronic format as described herein, then select the check-box next to ‘I agree to use electronic records and signatures’ before clicking ‘CONTINUE’ within the DocuSign system. By selecting the check-box next to ‘I agree to use electronic records and signatures’, you confirm that:  You can access and read this Electronic Record and Signature Disclosure; and  You can print on paper this Electronic Record and Signature Disclosure, or save or send this Electronic Record and Disclosure to a location where you can print it, for future reference and access; and  Until or unless you notify Jonathan Leung as described above, you consent to receive exclusively through electronic means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you by Jonathan Leung during the course of your relationship with Jonathan Leung. Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 1429 S Garnsey St, Santa Ana, CA 92707 MONA LEE SOLAR CA LLC 1106502 Adrian Ramli 415 943 6444 permits@monalee.co 6/3/2025 DATE: May 19, 2025 RE: 1429 S GARNSEY ST, SANTA ANA, CA 92707, USA To Whom It May Concern, As per your request, we have conducted a structural assessment of the building at the above address. PV solar panels are proposed to be installed on roof areas as shown in the submitted plans. The panels are clamped to rails which are attached to the roof with a lagged mounting system. The PV system (PV modules, racking, mounting hardware, etc.) shall be installed according to the manufacturer’s approved installation specifications. The Engineer of Record and Exactus Energy claim no responsibility for misuse or improper installation. It was found that the roof structures satisfactorily meet the applicable standards included in the 2022 California Building Code, 2022 California Residential Code, 2022 California Existing Building Code, and ASCE 7-16 as well as the design criteria shown below: Design Criteria: Risk Category = II Exposure Category = B Wind speed = 95 mph Ground snow load = 0 psf Roof dead load = 9 psf Solar system dead load = 3 psf Overall, the roof area is structurally adequate to support the PV alteration with no modifications or reinforcements as required per 2022 California Existing Building Code Sections 502.4 and 503.3 The roof framing was found to be made up of 2X4 @ 24" O/C lumber rafters topped with board sheathing and rolled composition. The condition of the roof was found to be in good condition. The calculations produced for this structure's assessment are only for the roof framing supporting the proposed PV installation referenced in the stamped planset and were made according to generally recognized structural analysis standards and procedures. This letter was completed in accordance to recognized design standards, professional engineering experience, and judgement. Prior to installation, the on-site contractor must notify Exactus Energy if there are any discrepancies, or damages to the members, that were not addressed in the plan set. If you have any further questions, please do not hesitate to contact me. Acknowledged by: EXP 3/31/2026Jeff Onorati Digitally signed by Jeff Onorati Date: 2025.05.20 11:48:59 -07'00' Inputs Roof 1 Unit Roof Dead Load (DLr)9 psf Roof Live Load (LLr)20 psf Roof Snow Load (SLr)0 psf (DLr+LLr)/Cd =23.2 psf (DLr+SLr)/Cd=7.83 psf Max. Existing Gravity Load 23.2 psf Roof Dead Load with PV Panel Load (DL)12 psf Roof Live Load (LL)0 psf Roof Snow Load (SL)0 psf (DL+LL)/Cd =13.33 psf (DL+SL)/Cd=10.43 psf Max. Proposed Gravity Load 13.33 psf % Change =-42.54 % Proposed Gravity Loads The change in gravity loads for Roof 1 after the proposed solar installation is less than 5%, therefore passes the Impact Check. IEBC IMPACT CHECK Existing Gravity Loads ASCE 7-16 1 | P a g e ASCE 7 - 16 WIND CALCULATION FOR: Roof 1 Project Address: 1429 S GARNSEY ST, SANTA ANA, CA 92707, USA DESIGN CRITERIA Ultimate Wind Speed: 95 mph Exposure Category: B a: 3 ft Velocity Pressure Exposure Coefficient, Kz: 0.57 Topographic Factor, Kzt: 1 Wind Directionality Factor, Kd: 0.85 Ground Elevation Factor, Ke: 1 Solar Array Pressure Equalization Factor, γa: 0.72 / 0.7 Array Edge Factor, γE: 1.5 Solar Array Dead Load: 3.4 psf Mean Roof Height: 12 ft Roof Pitch: 5° Roof Type: Flat / Low-Sloped Module Name, Dimensions, Area: JA SOLAR: JAM54S31 405/MR 405W, 44.6in X 67.8in, 3023.88 sqin CALCULATION Velocity Pressure Due to Wind: 𝑞𝑞ℎ = 0.00256(𝐾𝐾𝐾𝐾)(𝐾𝐾𝐾𝐾𝐾𝐾)(𝐾𝐾𝐾𝐾)(𝐼𝐼)(𝑉𝑉2) (𝐶𝐶ℎ 26.𝐸𝐸𝑞𝑞 26.10 −1) Actual Uplift Pressure: p = 0.6𝐷𝐷+0.6𝑊𝑊 (𝐶𝐶ℎ 2.4.1 𝐿𝐿𝐶𝐶 #7/𝑎𝑎) Wind Uplift Pressure: 𝑝𝑝= 𝑞𝑞ℎ (𝐺𝐺𝐶𝐶𝑝𝑝)(𝑦𝑦𝐸𝐸 )(𝑦𝑦𝑎𝑎 ) (𝐶𝐶ℎ 29.𝐸𝐸𝑞𝑞 29.4 −7) Landscape Panels Roof Zone 1 1' 2 3 Mount Spacing 48” 48” 48” 48” External Pressure Coefficient (GCp) -1.7 -0.9 -2.3 -3.2 Actual Uplift Pressure (p) -16 psf -16 psf -14.79 psf -21.37 psf Tributary Area (AT) 7.43 sqft 7.43 sqft 7.43 sqft 7.43 sqft Uplift Force (P) -118.93 lbs -118.93 lbs -109.93 lbs -158.86 lbs Portrait Panels Roof Zone 1 1' 2 3 Mount Spacing 48” 48” 48” 48” External Pressure Coefficient (GCp) -1.68 -0.9 -2.27 -3.14 Actual Uplift Pressure (p) -16 psf -16 psf -14.19 psf -20.42 psf Tributary Area (AT) 11.3 sqft 11.3 sqft 11.3 sqft 11.3 sqft Uplift Force (P) -180.8 lbs -180.8 lbs -160.37 lbs -230.72 lbs Uplift Capacity Attachment Type = 4 60mm Lag Screw Lagged into Rafters Hardware Pullout Capacity = 447 lbs Embedment Depth = 2.5 in Safety Factor = 1.5 Duration Factor = 1.6 Maximum Uplift Force = 158.862 lbs / 230.722 lbs Allowable Pullout Capacity = 447 lbs Allowable Pullout Capacity = 447 lbs > Uplift Force per Bolt = 158.86 lbs, Therefore OK. (Landscape) Allowable Pullout Capacity = 447 lbs > Uplift Force per Bolt = 230.72 lbs, Therefore OK. (Portrait) ML Installations CA LLC dba ML Solar & Electrical Installations CA | CSLB #1106502 Class C-10 5325 Elkhorn Blvd, Sacramento, CA 95842 | monalee.co To whom it may concern, ame oin, ameron nc, nia y and Adrian Ramli hae the riht an ermiion to act a an aent o ntaation an ona ee nc rearin matter concernin ine icene, iin ermit, an a other reate actiitie Walid Halty, CEO/Co-Founder walid@monalee.co (781) 558-7018 Commonwealth of Virginia County of Prince William The foregoing instrument was acknowledged before me on 08/04/2023 by Walid Halty as CEO of  ML Installations CA LLC and Mona Lee Inc. 7999724 My commission expires: 01/31/2026 Notarized online using audio-video communication CITY OF SANTA ANA Planning and Building Agency Planning & Building Agency Permits & Plan Check Section 20 Civic Center Plaza P.O. Box 1988 (M-19) =^ Santa Ana, CA 92702 'Y (714) 647-5800 EXISTING ONE & TWO FA ELECTRICAL SERVICE MOTS, r, r p•� 9t � EXCEPTION Ma6Q: Dat(jCEC 2019 ELC-04 All new utility connections are required to be installed below grade by Santa Ana Municipal Code 41- 626(b). There is a standing exception for existing one and two family dwellings. This exception applies only when the new electrical service is designed to be fed from below grade as well as overhead. This diagram is a typical unit. The utility is able to feed this cabinet from the top or the bottom without interfering with the distribution wiring. All the circuit breakers and branch circuits are contained in the circuit breaker side of this cabinet. Only listed combination overhead and underground feed service boxes may be used to connect to an overhead utility drop. This exception to an underground fed service applies only to existing single family and two family residences. OEM 00(p Rigid Conduit Service Entrance Conductor Riser 090@ 8"{ D U Ebw 29(ft Future Underground Service Lateral New service location may NOT be under a patio cover structure. -SCE A surface -mounted combination service rquires no raceway provision for future underground feed. When new service is semi -flush or flush mounted, a 3 inch rigid raceway is needed. Cap straight stub - out at a depth of 12 inches below grade. A sweep is capped at 30 inches below grade. Rev. 1 /21 /2020 www.santa-ana.org/pba/ Page 1 of 1