HomeMy WebLinkAboutHOLD - 1430 & 1432 N Baker St - REV 1 - Plan62.02'PROPERTY LINE 62.02'PROPERTY LINE 15 4 . 6 6 ' PR O P E R T Y L I N E PR O P E R T Y L I N E 15 4 . 6 6 ' SCALE 1/8"=1'-0" SITE PLAN 1432 N. BAKER ST. UNIT #2 SINGLE FAMILY DWLG. 2,594.00 S.F. EXISTG. 2-STORY NOTE: THE APPLICANT/PROPERTY OWNER SHALL BE RESPONSIBLE FOR CONFIRMING ALL EXISTING UTILITY EASEMENTS AND/OR CLEARANCES ON-SITE THAT MAY AFFECT THE PROJECT. EXIST. PORCH REAR YARD EXIST. LANDSCAPE FRONT YARD EXIST. LANDSCAPE TO BE ADU 297.00 S.F. EXISTG. GARAGE EXIST. BRICK. WALKWAY EXIST. PATIO EX I S T . C O N C . D R I V E W A Y EX I S T . C O N C . D R I V E W A Y EX I S T . C O N C . D R I V E W A Y EXISTG. SWIMMING POOL EX I S T . S I D E Y A R D EX I S T . S I D E Y A R D 11 ' - 2 " 18 ' - 2 " 13 ' - 3 " 1'-3"16'-4"5'-0"39'-5" NORTH (EXISTG.) DRIVEWAY APPROACH(E) CURB & GUTTER EXISTG. SIDEWALK EXISTG. PARKWAY PROVIDE SAND BAGS PROVIDE 6'-0" HIGH TEMPORARY CHAIN LINK FENCE ********* (EXISTG.) WALKWAY APPROACH A A-2 1%MI N 1%MI N 1%MI N 1%MI N 1%MI N1%MI N 1%MI N 1%MI N 1%MI N 1%MI N 1%MI N 5% 5% 5%5% 5%5% (E) TREE (E) BUSHES 36 ' - 6 " 49 ' - 5 " 68 ' - 8 " NOTE: NO EASEMENT ON PROPERTY (E ) 3 F T H I G H B L O C K F E N C E (E ) 6 F T H I G H B L O C K F E N C E (E ) 6 F T H I G H B L O C K F E N C E (E ) 6 F T H I G H V I N Y L F E N C E (E ) 6 F T H I G H V I N Y L F E N C E (E) 6 FT HIGH VINYL FENCE PROVIDE 6'-0" HIGH VINYL GATE 11 ' - 0 " 23'-0" TANKLESS WATER HEATER (E) GAS METER (N) GAS METER (N ) G A S L I N E T O A D U (N) GAS LINE (E) SEWER LATERAL (N ) S E W E R L I N E (N ) S E W E R L I N E (E ) S E W E R L I N E (E ) S E W E R L I N E VERIFY (E) 4" SEWER LATERAL (N) 4" SEWER LATERAL (N) 100 AMP SUBPANEL (E) ELECTRICAL PANEL (N) 100 AMP ELECTRICAL SUB-PANEL (E) WATER METER (N ) W A T E R L I N E (E ) W A T E R L I N E (N) W A T E R L I N E (E)UNPERMITTED CARPORT STRUCTURE TO BE REMOVED A A 10'-3" REF. SCALE 1/4"=1'-0" ADU FLOOR PLAN LEGEND: PROPOSED EXISTING REMOVE 4'-0" CLOSET BATH 10'-1" 14 ' - 1 1 " 15'-6" 9' - 5 " HIGH EFFICIENCY FIXTURES ELECTRICAL LEGEND G.F.I. SWITCHES FLUORESCENT FIXTURE 40 LUM A.F.C.I. ARC FAULT CURRENTINTERRUPTER RECEPTACLE H.E. SENSOR OFF ON AND PHOTO-CONTROLLED LIGHTING W/ MOTION SENSORP SWITCHES W/ DIMMERD G.F.I. W/P WP/GFI OUTLET TYP. EXHAUST FAN- CAPABLE OF 5 AIR CHANGES/HOUR IN BATHROOM AND/OR TOILET ROOM. HUMIDISTAT CONTROLLED SD HARD-WIRED CARBON MONOXIDE ALARM WITH BATTERY BACKUP CO LIGHT FIXTURES ELECTRICAL RECEPTACLE TAMPER PROOF1 WARDROBE SHELF & POLE2 3 4 5 6 FLOOR PLAN KEYNOTES WATER CLOSET SHALL BE ULTRA LOW FLUSH TYPE WITH 1.28 GAL. MAX. PER FLUSH. HOSE BIBB W/ BACKFLOW PREVENTER 7 ENERGY STAR EXHAUST FAN W/ 5-AIR CHANGES PER HOUR EXHAUSTING DIRECTLY TO THE OUTSIDE/ 50 CFM EXHAUST PER CGBSC 4.506.1. WITH HUMIDITY CONTROL LANDING 8 9 10" X 19" STOVE TOP 16" X 14" S. STL SINK W/ GARB. DISPOSAL ON A SEPARATE CIRCUIT. 10 F.A.U. IN ATTIC 13.5EER CAPACITY HEATER & COOLER SEE NOTES 30"X30" ATTIC ACCESS W/ 30" MIN. HEADRM. W/ WEATHER STRIPS TO PREVENT BACK DRAFT. 11 12 GRAB BARS NOTES A.REINFORCEMENT FOR GRAB BARS. [R327.1.1] AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BE PROVIDED WITH REINFORCEMENT INSTALLED IN ACCORDANCE WITH THIS SECTION. WHERE THERE IS NO BATHROOM ON THE ENTRY LEVEL, AT LEAST ONE BATHROOM ON THE 2ND OR 3RD FLOOR OF THE DWELLING SHALL COMPLY WITH THIS SECTION. 1.REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING AGENCY. 2.REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH NOMINAL LUMBER (1-1/2” X 7-1/4” ACTUAL DIMENSION) OR OTHER CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD CAPACITY. REINFORCEMENT SHALL BE LOCATED BETWEEN 32” AND 39-1/4” ABOVE THE FINISHED FLOOR, FLUSH WITH THE WALL FRAMING. 3.WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. 4.SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. 5.BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS ON EACH END OF THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN 6” ABOVE THE BATHTUB RIM. 6.WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE WALL CAPABLE OF ACCOMMODATING A GRAB BAR, THE BATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION OF FLOOR-MOUNTED, FOLDAWAY OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS APPROVED BY THE ENFORCING AGENCY. B.DOCUMENTATION FOR GRAB BAR REINFORCEMENT. [R327.1.1.1] INFORMATION AND/OR DRAWINGS IDENTIFYING THE LOCATION OF GRAB BAR REINFORCEMENT SHALL BE PLACED IN THE OPERATION & MAINTENANCE MANUAL IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE, CH. 4, DIVISION 4.4. C.ELECTRICAL RECEPTACLE OUTLET, SWITCH & CONTROL HEIGHTS. [R327.1.2] ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS (INCLUDING CONTROLS FOR HEATING, VENTILATION AND AIR CONDITIONING) INTENDED TO BE USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48” MEASURED FROM THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15” MEASURED FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR. D.INTERIOR DOORS. [R327.1.3] EFFECTIVE JULY 1, 2024, AT LEAST ONE BATHROOM AND ONE BEDROOM ON THE ENTRY LEVEL SHALL PROVIDE A DOORWAY WITH A NET CLEAR OPENING OF NOT LESS THAN 32”, MEASURED WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM THE CLOSED POSITION; OR, IN THE CASE OF A 2- OR 3-STORY SINGLE FAMILY DWELLING, ON THE 2ND OR 3RD FLOOR OF THE DWELLING IF A BATHROOM OR BEDROOM IS NOT LOCATED ON THE ENTRY LEVEL. E.DOORBELL BUTTONS. [R327.1.4] DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT EXCEED 48” ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. WHERE DOORBELL BUTTONS INTEGRATED WITH OTHER FEATURES ARE REQUIRED TO BE INSTALLED ABOVE 48” MEASURED FROM THE EXTERIOR FLOOR OR LANDING, A STANDARD DOORBELL BUTTON OR CONTROL SHALL ALSO BE PROVIDED AT A HEIGHT NOT EXCEEDING 48” ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON OR CONTROL. SMOKE DETECTOR SHALL BE INTERCONNECTED SUCH THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS. A MINIMUM OF 20 FT. FROM PERMANENT COOKING EQUIPMENT (OR 10' WITH PHOTO-ELECTRIC TYPE). SMOKE ALARM AND DETECTORS WILL BE INSTALLED AND MAINTAINED ACCORDING TO MANUFACTURER'S INSTRUCTIONS. HARDWIRED SMOKE DETECTOR W/ BATTERY BACK-UP (PHOTO ELECTRIC) WATER HEATING. SYSTEMS USING GAS OR PROPANE WATER HEATERS TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE THE FOLLOWING COMPONENTS [150.0(N)]: A.A DEDICATED 125V, 20A (10 AWG COPPER BRANCH CIRCUIT) ELECTRICAL RECEPTACLE THAT IS WITHIN 3 FEET FROM THE WATER HEATER AND ACCESSIBLE TO THE WATER HEATER WITH NO OBSTRUCTIONS. THERE SHALL BE A RESERVED SINGLE POLE BREAKER SPACE IN THE ELECTRICAL PANEL LABELED "FUTURE 240V USE". BOTH ENDS OF THE UNUSED CONDUCTOR SHALL BE LABELED WITH THE WORD “SPARE” AND BE ELECTRICALLY ISOLATED. B.A CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES HIGHER THAN THE BASE OF THE INSTALLED WATER HEATER, AND ALLOWS NATURAL DRAINING WITHOUT PUMP ASSISTANCE. C.DESIGNATE A SPACE AT LEAST 2.5 FT. BY 2.5 FT. WIDE AND 7 FT. TALL SUITABLE FOR THE FUTURE INSTALLATION OF A HEAT PUMP WATER HEATER (HPWH). D.IF DESIGNATED SPACE IS MORE THAN 3 FEET FROM WATER HEATER, COMPLY WITH 150.0(N)B. A.ELECTRIC COOKTOP READY. SYSTEMS USING GAS OR PROPANE COOKTOP TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE THE FOLLOWING: 1.A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FT. FROM THE COOKTOP AND ACCESSIBLE TO THE COOKTOP WITH NO OBSTRUCTIONS. THE BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT 50 AMPS MINIMUM. THE BLANK COVER SHALL BE IDENTIFIED AS “240V READY”. 2.THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE ELECTRIC COOKTOP INSTALLATION. THE RESERVED SPACE SHALL BE PERMANENTLY MARKED AS “FOR FUTURE 240V USE.” B.ELECTRIC CLOTHES DRYER READY. CLOTHES DRYER LOCATIONS WITH GAS OR PROPANE PLUMBING TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE THE FOLLOWING: 1.A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FT. FROM THE CLOTHES DRYER LOCATION AND ACCESSIBLE TO THE CLOTHES DRYER LOCATION WITH NO OBSTRUCTIONS. THE BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT 30 AMPS MINIMUM. THE BLANK COVER SHALL BE IDENTIFIED AS “240V READY.” 2.THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE ELECTRIC CLOTHES DRYER INSTALLATION. THE RESERVED SPACE SHALL BE PERMANENTLY MARKED AS “FOR FUTURE 240V USE.” VACANCY SENSORVS SHOW COMPLIANCE WITH THE FOLLOWING LIGHTING MEASURES: [150.0(K) / 160.5(A)] 1.A.LIGHTING IN BATHROOMS, GARAGES, LAUNDRY ROOMS, WALK-IN CLOSETS AND UTILITY ROOMS. ALL LUMINAIRES SHALL BE HIGH EFFICACY AND SHALL BE CONTROLLED BY AN OCCUPANCY OR VACANCY SENSOR NOTE: HIGH EFFICACY LUMINARIES MUST BE PIN BASED IN ADDITION TO THE LOCAL EXHAUST FANS IN THE BATHROOMS AND KITCHENS, AN EXHAUST FAN SHALL BE SIZED TO PROVIDE VENTILATION FOR THE WHOLE HOUSE. THE MINIMUM VENTILATION RATE FOR THE IAQ FAN SHALL BE CALCULATED ACCORDING TO ASHRAE STANDARD 62.2 AND 150.0(O)C / 160.2. ONE OF THE LOCAL EXHAUST FANS IN THE BATHROOMS OR KITCHENS MAY BE USED TO MEET THE WHOLE-BUILDING VENTILATION, PROVIDED THE EXHAUST FAN MEETS THE MINIMUM VENTILATION RATED FOR BOTH THE LOCAL EXHAUST AND IAQ REQUIREMENTS. THE DUCTING FOR THE WHOLE BUILDING EXHAUST FAN SHALL BE SIZED ACCORDING TO TABLE 150.0-H / 160.2-H, AND THIS EXHAUST FAN SHALL OPERATE CONTINUOUSLY. THE WHOLE-BUILDING VENTILATION EXHAUST FAN WILL OPERATE CONTINUOUSLY AND IS REQUIRED TO BE RATED FOR SOUND AT A MAXIMUM OF 1 SONE. THIS EXHAUST FAN CAN BE CONTROLLED BY A STANDARD ON/OFF SWITCH BUT THE SWITCH MUST BE LABELED CLEARLY DISPLAYING THE FOLLOWING TEXT, OR EQUIVALENT: “THIS SWITCH CONTROLS THE INDOOR AIR QUALITY VENTILATION FOR THE HOME. LEAVE SWITCH IN THE 'ON' POSITION AT ALL TIMES UNLESS THE OUTDOOR AIR QUALITY IS VERY POOR.” [150.0(O)J] WATER HEATERS SHALL BE ANCHORED OR STRAPPED TO THE STRUCTURE [CPC 507.2]. A KITCHEN IS DEFINED AS ANY ROOM CONTAINING COOKING APPLIANCES. EACH KITCHEN IS REQUIRED TO HAVE AN EXHAUST FAN DUCTED TO THE OUTSIDE WITH A MINIMUM VENTILATION RATE AND CAPTURE EFFICIENCY PER TABLE 150.0-G OR TABLE 160.2-G (MULTI-FAMILY). THE RANGE HOOD OVER THE STOVE MAY BE USED TO MEET THIS REQUIREMENT BUT THE RANGE HOOD MUST VENT TO THE OUTSIDE; RECIRCULATING RANGE HOODS CANNOT BE USED. THE DUCTING FOR THE EXHAUST FAN SHALL BE SIZED ACCORDING TO ASHRAE STANDARD 62.2 TABLE 7.1. THIS LOCAL EXHAUST FAN MAY OPERATE CONTINUOUSLY OR INTERMITTENTLY. INSTALLING THIS LOCAL EXHAUST FAN IN THE KITCHEN WILL ALLOW THE HOME OCCUPANT TO REGULATE THE INDOOR AIR QUALITY WHEN NEEDED. 100 CFM IS NOT ADEQUATE; 280 CFM FAN REQUIRED PER TABLE 150.0-G. GROUND FAULT FOR 120 VOLT, 15/20AMP RECEPTACLE STUDY KITCHEN 5'-8" 3'-0" 4' - 0 " 7 7 7' - 9 " 10 ' - 1 " 16'-4" 18 ' - 2 " 16'-4" 18 ' - 2 " 1 5'-0" X 3'-6" 2 SYM. SIZE TYPE WINDOW SCHEDULE VINYL SLID. 3 4'-0" X 4'-0" 3'-0" X 1'-0" VINYL SLID. VINYL SLID. TEMPERED GLASS U-FACTOR SHGC 0.30 0.23 0.30 0.23 0.30 0.23 DOOR SCHEDULE SYM. SIZE A HOLLOW CORE B TYPE C DOOR SCHEDULE SYM. SIZE A HOLLOW CORE B TYPE C 2'-10"X6'-8"X1 3/8" D SOLID CORE3'-0" X 6'-8" X 1 3/4" E 6'-0" X 6'-8"SLID. WOOD DBL. DRS. 2 1 2' - 8 " 15 ' - 7 " 3' - 0 " 30 " M I N . 24" MIN. 5'-0" A.F.C.I.A.F.C.I. A.F.C.I. A.F.C.I. A.F.C.I. A.F.C.I. A.F.C.I. G.F.I.G.F.I.G.F.I.G.F.I. G.F.I. VS D P P SOLID CORE2'-8"X6'-8"X1 3/8" B D1" MAX. DIFF. A C SD CO SHOWER WITH CEMENT PLASTER, TILE, OR APPROVED COVERING EQUAL WITH 72" (MINIMUM) HIGH ABOVE DRAIN NON-ABSORBENT WALLS. MATERIALS OTHER THAN STRUCTURAL ELEMENTS ARE TO BE MOISTURE RESISTANT 1 2 3 4 F.A.U. IN ATTIC 10 5 8 9 G.F.I. W/P G.F.I. W/P 3 TEMP GLASS 1-HR FIRE RATED WALL EXHAUST FAN W/ 20 CFM Single-Speed Whole House Ventilation Fan from the Eco-Exhaust Series PER ASHRAE 62.2 MANUFACTURER: AIRKING EVD WHOLE HOUSE VENTILATION a. Qr= 0.01 X 297.00 +7.5 (1+1) a. Qr= 0.01 X 770.00 +15.00 = 17.97 cfm b. 1 Sone max c. 4" duct 15'-0" max length 1" MAX. DIFF. 2" X 6" BACKING FOR FUTURE GRAB BAR INSTALLATION SEE DETAIL 1/A-2 30" M I N A-2 X TANKLESS WATER HEATER 1'-8" X 6'-8" X 1 3/4"SOLID CORE W/ LOUVER VENTS TEMPERED GLASS TEMP GLASS 6 SHOWER DOOR TO BE TEMPERED GLASS 2'-10" DOOR ALARM FOR POOL 15 " MI N 15 " MI N (N) 100 AMP ELECTRICAL SUB-PANEL LAUNDRY A A A A-1 SITE PLAN, FLOOR PLAN ISSUES AND REVISIONS Computer File Project Name Description Project Number SHEET: Scale NO. 1. DATE 2. 3. CHECKBY CONSULTANT CONTACT: PROPOSED GARAGE CONVERSION INTO ADU SEAL: VERIFY MEASUREMENTS WITH CORRESPONDING COSTRUCTED OR EXISTING CONDITIONS PRIOR TO PROCEEDING WITH THE WORK, AND NOTIFY THE ARCHITECT IMMEDIATELY OF SIGNIFICANT DISCREPANCIES. FINISH ELEVATIONS REFERENCED ON ARCHITECTURAL DRAWINGS ARE DATUM ELEVATIONS ABOVE THE FINISH FLOOR ELEVATION. THE CONTRACTOR MUST COORDINATE DATUM-BASED ARCHITECTURAL ELEVATIONS SHOWN WITH SITE-SPECIFIC ELEVATIONS SHOWN ON CIVIL DRAWINGS. WALL DIMENSIONS SHOWN ARE TO FACE OF WALL FINISH UNLESS SPECIFICALLY NOTED OTHERWISE. 1432 N. BAKER ST. SANTA ANA, CA 92706 C&C Drafting Design Edgar Cortes & Commercial Residential Design 1100 E. Orangethorpe Ave. Ca. 92801 # 200w, Anaheim (562) 916 7505 (714) 813 6555 e_mail: ccdraftingdesign@yahoo.com OWNER: MRS. MINEL HERAS Mobile: (562) 547 4249 MRS. MOUREEN B. HERAS Mobile: (562) 547-4249 EMAIL: INPROPERBUENAPARK@GMAIL.COM A 2/05/2026 ROOF FRAMING PLAN, RELOCATE WATER HEATER, ELECTRICAL PANEL. CONCRETE SLAB DETAIL AND ROOF SHEATHING A-1 INDEX OF DRAWINGS SITE PLAN, PROPOSED FLOOR PLAN 9,588.00 SQ.FT. 3,144.00 SQ.FT. LOT AREA TOTAL EXISTING AND PROPOSED 2,594.00 SQ.FT.EXISTING LIVING AREA 297.00 SQ.FT. PROJECT DATA: LOT COVERAGE = 3,144.00 SQ.FT. / 9,588.00 SQ.FT.X 100 =32.79% TOTAL EXISTING HOUSE, GARAGE & ADDITION SCOPE OF WORK: PROPOSED GARAGE CONVERSION INTO ADU: EXISTING GARAGE 297.00 SQ.FT. INTO ADU INCLUDE; STUDY, CLOSET, BATH, KITCHEN AND LIVING/DINING AREA. LEGEND PROPOSED ADU APPLICABLE CODES BUILDING ANALYSIS OCCUPANCY CLASSIFICATION: R3 TYPE OF CONSTRUCTION: V-B EXISTING 2-CAR GARAGE TO BE ADU LEGAL DESCRIPTION THE GOVERNING CODES FOR THIS PROJECT ARE 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA ELECTRIC CODE BASED ON NEC 2022 BUILDING ENERGY EFFICIENCY STANDARDS SANTA ANA MUNICIPAL CODE CA RESIDENTIAL CODE ADU SPRINKLERS: NO NUMBER OF STORIES: 1 NOTES ZONING: R-1 SINGLE FAMILY RESIDENCE ZONE APN. 405-251-13 MECHANICAL, ELECTRICAL, AND PLUMBING ARE NOT PART OF THIS PLAN REVIEW AND APPROVAL. MEP ARE SUBJECT TO BUILDING FIELD INSPECTION VICINITY MAP PROJECT LOCATION A-2 ELEVATIONS, CROSS SECTION GRN GRN2 S-1 FOUNDATION AND ROOF FRAMING PLAN EN-1 ENERGY FORMS GREEN MANDATORY MEASURES GREEN MANDATORY MEASURES EXISTING MAIN HOUSE SPRINKLERS: NO 253.00 SQ.FT.EXISTING PATIO UTILITIES WILL BE UNDERGROUND FLOOD ZONE: X ADU SF / SFD SF = 297.00 SF / 2,594.00 SF = 0.11449 = 11.45% THE ADU SF / SFD SF RATIO IS FOR PARK & REC FEE PURPOSE ONLY. THE APPLICANT IS RESPONSIBLE FOR THE GIVEN “SFR SF” OF THE EXISTING PRIMARY RESIDENCE; BUILDING SAFETY STAFF ARE NOT RESPONSIBLE FOR THE ACCURACY OF THE GIVEN “SFR SF” OF THE EXISTING RESIDENCE. ADU/SFD SF KAMAL MCHANTAF 949-307-6346 ENGINEER INFORMATION (E) 1" STUCCO TYP. (E) 1" STUCCO TYP. (E) 1" STUCCO TYP. (E) 1" STUCCO TYP. (EXISTG.) ROOF (EXISTG.) ROOF NEW 1" STUCCO (E) 1" STUCCO TYP. 12 ' - 8 " SCALE 1/4"=1'-0" ADU EAST ELEVATION SCALE 1/4"=1'-0" ADU WEST ELEVATION SCALE 1/4"=1'-0" ADU SOUTH ELEVATION SCALE 1/4"=1'-0" ADU NORTH ELEVATION SILL HEIGHT NOTE: SILL HEIGHT NO TO EXCEED 44" FOR BEDROOM ESCAPE WINDOWS ATTIC AREA = 297.00 S.F. ATTIC VENTILATION: (3) 24"X12" DORMER VENTS = 297 / 150 = 1.98 S.F. REQUIRED 2.04 S.F. TOTAL = 2.04 S.F. PROVIDED ENCLOSED ATTICS AND RAFTER SPACES SHALL HAVE CROSS VENTILATION. FOR EACH SEPARATE SPACE, THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/150 OF THE AREA OF THE SPACE VENTILATED, THE TOTAL AREA IS PERMITTED TO BE REDUCED TO 1/300, PROVIDED AT LEAST 40% AND NOT MORE THAN 50% OF THE REQUIRED VENTILATING AREA IS LOCATED IN THE UPPER PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3' ABOVE EAVE OR CORNICE VENTS WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. VENT OPENINGS SHALL BE PROVIDED WITH CORROSION-RESISTANT WIRE MESH WITH 1/16" MINIMUM TO 1/4" MAXIMUM OPENINGS. A MINIMUM OF A 1-INCH AIRSPACE MUST BE MAINTAINED BETWEEN THE INSULATION AND THE ROOF SHEATHING AT THE LOCATIONS OF THE VENTS. [CRC R806] NOTE: 26 GA. GALV. STL. 26 GA. GALV. STL. 26 GA. GALV. STL. 26 GA. GALV. STL. AN APPROVED PLUMBING FIXTURE. 5. CONDENSATE DRAIN, IF ANY, SHALL BE CONVERTED TO 3. SEISMIC SWAY BRACES OR ANCHOR UNIT TO PLATFORM 1. DOUBLE JOISTS SUPPORTING THE F.A.U. 2. LEVEL PLATFORM 4. LIGHT , SWITCH , OUTLET. REQUIREMENTS PER ATTIC - INSTALLED FAU: 6. PROVIDE PASSWAY 24" INCHES WIDE OF SOLID CONTINUOUS FLOORING FROM SCUTTLE TO EQUIPMENT AND ITS CONTROLS. LENGHT OF THE PASSWAY SHALL NOT EXCEED 20 FT. FOR ALL PLANS NO SCALE TYPICAL F.A.U. DETAIL ROUTINE INSPECTIONS AND MAINTENANCE BY THE OWNER/OCCUPANT AND FOR SERVICE AND REPAIR AS NEEDED. CHANGING FILTERS, LUBRICATING MOTOR AND FAN CENTRAL WARM-AIR FURNACES INSTALLED IN ATTIC MUST BE ACCESSIBLE FOR SERVICE INTERRUPTION ARE NORMAL OWNER FUNCTIONS. ADEQUATE LIGHT, AND CONTROL SIDE ALL ENCOURAGE AND FACILITATE MAINTENANCE AND ALSO ENABLE BEARING, CHECKING BELT TENSION, AND RELIGHTING THE PILOTFOLLOWING A ELECTRICAL OUTLET, SAFE ACCES WAY AND SUFFICIENT WORKING SPACE PON THE RELATED CODE SECCION: 509, 708 RAPID EGRESS IN AN EMERGENCY. WORKING SPACE AT CONTROL 30" 2' - 0 " A B O V E A N Y RO O F S U R F A C E 10 ' A W A Y PROVIDE POSITIVE ELECTRICAL DISCONECT (SEE SEC. 509) LIGHT OVER CONTROLS 24" WIDE SOLID FLOORING ACCES WAY. LOCATE MIN. 2 DORMER VENTS NEXT TO F.A.U. IN ATTIC FOR COMBUSTI0N AIR PROVIDE MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS PER MANUFACTURERS SPECS. 5' - 0 " MI N (SEE SEC. 906(b)) WARM-AIR FURNACE 20" MAXVENT THRU ROOF A MINIMUM OF 5'-0" ABOVE THE HIGHEST VENT COLLAR WHICH IT SERVES 30"X30" ACCES OPENINGDOUBLE JOIST AROUND A/C UNIT DORMER VENT LIGHT SWITCH 32 " M I N A B O V E F I N I S H F L O O R 38 " M A X A B O V E F I N I S H F L O O R 2" X 6" BACKING FOR FUTURE GRAB BAR INSTALLATION GRAB BAR GRAB BAR BACKING DETAIL -1- NOT TO SCALE1-HR FIRE RATED EAVE A PER CBC TABLE 721.1(2) ITEM 16-1.1 (Q) (P.I.32/16) 8d @ 6",12" O/C OVER 2"X ROOF RAFT. @ O/C DBL. 2"X4" PLATES 2"X CLG. JSTS. @ 16" O/C 2"X4" STUDS @ 16" O/C FOR EXT. FINISH 7/8" MIN. STUCCO OR SEE ELEVATION B.N. 6-16d PER LAP A35 @ 24" O/C 5/8" TYPE "X" GYP. BRD. FROM P.T. SILL TO BOTT. OF ROOF SHTG. FOR 1-HR. FIRE CONSTRUCTION E.N. WEEP SCREED TYP. 26 GA. GALV. STL. AT STUCCO WITH 3 -1/2" FLANGE 5-16d/LAP A35@ 24" O/C CROSS SECTION X SCALE 3/8"=1'-0" (E) FOOTING (E) FOOTING 2" X " RIDGE BRD 12 5 8d @ 6",12" O/C OVER 5-16d/LAP A35@ 24" O/C (E) 2" X 4" STUDS @ 16" O.C. DBL. 2" X 4" PLATES (N) R-13 INSULATION 4" CONC. SLAB (N) R-13 INSULATION DINING/LIVING ROOM DBL. 2" X 4" PLATES 2" X 4" STUDS @ 16" O.C. 2" X " CLG. JSTS. @ 16" O/C R-30 INSULATION 2" X " FASCIA W/ 2-16d PER RAFT. TAIL TYP. (N) 2" X 6" R.R. @ 16" O.C. DORMER VENT 24"X12" G.S. DORMER VENT 24"X12" G.S. (E) 2-CAR GARAGE 16'-4" 18 ' - 2 " SCALE 1/4"=1'-0" (E) GARAGE FLOOR PLAN 17 ' - 4 " 15'-6" ADU ROOF PLAN SCALE 1/8"=1'-0" SLOPE (E) 5:12 SLOPE (E) 5:12 DORMER VENT (3) 24"X12" G.S. 12" TO MATCH (E) HOUSE SL O P E (E ) 5 : 1 2 SL O P E (E ) 5 : 1 2 SL O P E (E ) 5 : 1 2 SL O P E (E ) 5 : 1 2 SL O P E (E ) 5 : 1 2 SLOPE (E) 5:12 SLOPE (E) 5:12 SLOPE (N) 5:12 SLOPE (N) 5:12 (E) ROOF PLAN SCALE 1/8"=1'-0" LA N D I N G MA X H E I G H T 7- 3 / 4 " LA N D I N G MA X H E I G H T 7- 3 / 4 " 1/2" OSB EXT. GRADE PLYWD. 1/2" OSB EXT. GRADE PLYWD. A A-2 ELEVATIONS, CROSS SECTION ISSUES AND REVISIONS Computer File Project Name Description Project Number SHEET: Scale NO. 1. DATE 2. 3. CHECKBY CONSULTANT CONTACT: PROPOSED GARAGE CONVERSION INTO ADU SEAL: VERIFY MEASUREMENTS WITH CORRESPONDING COSTRUCTED OR EXISTING CONDITIONS PRIOR TO PROCEEDING WITH THE WORK, AND NOTIFY THE ARCHITECT IMMEDIATELY OF SIGNIFICANT DISCREPANCIES. FINISH ELEVATIONS REFERENCED ON ARCHITECTURAL DRAWINGS ARE DATUM ELEVATIONS ABOVE THE FINISH FLOOR ELEVATION. THE CONTRACTOR MUST COORDINATE DATUM-BASED ARCHITECTURAL ELEVATIONS SHOWN WITH SITE-SPECIFIC ELEVATIONS SHOWN ON CIVIL DRAWINGS. WALL DIMENSIONS SHOWN ARE TO FACE OF WALL FINISH UNLESS SPECIFICALLY NOTED OTHERWISE. 1432 N. BAKER ST. SANTA ANA, CA 92706 C&C Drafting Design Edgar Cortes & Commercial Residential Design 1100 E. Orangethorpe Ave. Ca. 92801 # 200w, Anaheim (562) 916 7505 (714) 813 6555 e_mail: ccdraftingdesign@yahoo.com OWNER: MRS. MINEL HERAS Mobile: (562) 547 4249 MRS. MOUREEN B. HERAS Mobile: (562) 547-4249 EMAIL: INPROPERBUENAPARK@GMAIL.COM A 2/05/2026 ROOF FRAMING PLAN, RELOCATE WATER HEATER, ELECTRICAL PANEL. CONCRETE SLAB DETAIL AND ROOF SHEATHING ROOF FRAMING PLAN SCALE 1/8"=1'-0" 2 " X 8 " R I D G E B O A R D (B-3) 4X8 HDR (B-1) 4X6 HDR (B - 5 ) 4 X 6 H D R (B - 4 ) 4 X 6 H D R 1 DL 2 DL ADL BDL (B-2) 4X8 HDR 3 - 2" X 8" CLG JOISTS 3 - 2" X 8" CLG JOISTS (N) 2" X 6" C.J. @ 16" O.C. 4 L=8'-0" HDU2 4X4 POST HDU2 4X4 POST L=8'-0"4 HDU2 4X4 POST HDU2 4X4 POST 4 L=6'-0"HDU2 4X4 POST HDU4 4X4 POST HDU4 4X4 POST L=5'-0"3 L=8'-0"4 HDU2 4X4 POST HDU2 4X4 POST 4 L=6'-0"HDU2 4X4 POST HDU4 4X4 POST HDU4 4X4 POST L=5'-0"3 1 DL 2 DL ADL BDL CF1 2" X 4" KICKER 2" X 4" KICKER 4' - 0 " 3'-0" 3' - 0 " 4'-0" FOUNDATION PLAN SCALE 1/8"=1'-0" 2 STRAP W/ 10-16d @ 4'-0" O/C SIMPSON ST-2115 SIDE EA. JOIST 2-16d T.N. EA. (E) RIDGE BOARD RIDGE & RAFT. DETAIL 1 A35 @ 24" O/C 8-16d PER LAP FOR EXT. FINISH OR SEE ELEVATION W/ 2-16d PER 2"X FASCIA ROOF RAFT. 7/8" MIN. STUCCO DBL. 2"X4" PLATES 2"X4" STUDS @ 16" O/C B.N. SHEARWALL WHERE OCCURS OR PER SHEARWALL SHEDULE FOR SHEAR WALL 2 SEISMIC: - SITE CLASS: D IMPORTANCE FACTOR, I : 1.0 - OCCUPANY CATEGORY: II SEISMIC DESIGN CATEGORY:D - Ss = 1.50 S1 = 0.54 LATITUDE: 33.7551871 - Sds = 1.18 Sd1 = 0.82 LONGITUDE:-117.883071 - SEISMIC FORCE RESISTING SYSTEM(S): PLYWD SHEAR WALLS - Cs = Sds / (R/I) = 0.1538 R = 6.5 - V = Cs * W (ASD) = 0.1538* W WIND: - BASIC WIND SPEED = 110 MPH IMPORTANCE FACTOR = 1.0 - OCCUPANCY CATEGORY: II WIND EXPOSURE CAT. = C - HEIGHT & EXPOSURE ADJ. COEFF: 1.00 - TOPOGRAPHIC ADJ. FACTOR: 1.0 - DESIGN WIND PRESSURE = 15.37 PSF = 1.3 12.0 PSF 20.0 PSF N/A 16.0 PSF 40.0 PSF FOUNDATION DESIGN - SOIL - TYPE 5 (SITE CLASS D USED FOR LATERAL DESIGN) - ALLOWABLE SOIL BEARING PRESSURE - 1,500 PSF. - RETAINING WALLS: RESTRAINED LOAD (EFP) = NA PCF CANTILEVERED LOAD (EFP) = NA PCF (LEVEL) PASSIVE SOIL PRESSURE = NA PCF / 2000 PCF MAX. COEFFICIENT OF FRICTION = NA - SOILS REPORT BY: N/A LATERAL DESIGN - ROOF DEAD LOAD = - ROOF LIVE LOAD = - ROOF SNOW LOAD = - WALL DEAD LOAD = - FLOOR LIVE LOAD = VERTICAL DESIGN DESIGN LOAD TABLE = 1.3 ALL INTERIOR FOOTINGS 18" BELOW. FOR EXPANSIVE SOIL CONDITIONS ALL EXTERIOR FOOTINGS SHALL BE 24" BELOW NATURAL GRADE AND NOTE: “Fasteners for preservative-treated or fire-retardant-treated wood shall be of hot dipped zinc - coated galvanized steel in accordance with ASTM A 153.” (R317.3) NOTE: “Specify that foundation sills shall be naturally durable or preservative-treated wood. Field-cut ends, notches and drilled holes of preservative-treated wood shall be field-treated per AWPA M4.(R317.1.1,2304.11.2.4) NAIL W/ 8d @ 6",12" O/C PENDICULAR TO FRAMING AND LAY PLYWD. FACE GRAIN PER- W/ EXT. GRADE GLUE (P.I.32/16) 1/2" OSB EXT. GRADE PLYWD. ROOF SHEATING: RADIANT BARRIER REQUIRED = W/2-#4 TOP & BOTT. TYP. NEW 12" X24"DEEP CONT. FTG. CF1 1 = 5/8" DIA. X 10" A. BOLTS @ 6'-0" O/C 12" FROM CORNERS & ENDS (7" MIN. EMBED.) W/ 3"X3"X0.229" STL. PLATE WASHERS 1 2"X4" STUDS @ 16" O/C DBL. 2"X4" PLATES W/ 2-16d PER 2"X FASCIA ROOF RAFT. E.N. E.N. RADIANT BARRIER STUCCO (WHERE OCCURS) OVER SHEARWALL E.N. 2"X4" CRIPPLES @ 16" O/C A35 PER SW. SCH. FASTENERS PER SHEARWALL SCHEDULE (N) 2" X 6" CJ @ 16" O.C. 3 4 SIMPSON PC POST CAP INVERTED 2 X KICKER PC POST CAP 3 X C.J. PER PLAN RIDGE PER PLAN 6 5 7 8 1 ---- 2 ---- 2 ---- 3 ---- 3 ---- 4 ---- 4 ---- 5 ---- 6 ---- 6 ---- 6 ---- 6 ---- HALF OF ABOVE VALUES. (8) WHEN SHEAR PANEL APPLIED TO BOTH SIDES OF WALL FRAMING, SPACING SHALL BE STAGGERED PLYWOOD E.N. (FOR EXISTING WALL, USE 2x SILL PLATE W/ 2x SOLID BLKG. (7) FOR NEW WALLS, 3x SILL PLATE AND STUD BETWEEN ADJACENT PLANELS REQUIRED. (9) ALL NAILS SHALL BE COMMON NAILS OR GALVANIZED BOX. 1"3 8"x31 2"x31 2" 5 16"x3"x3"7 8" 3 4"5 16"x33 4"x23 4" 1 4"x3"x3" USE PLATE WASHERS SIZE:FOR ANCHOR BOLT SIZE: 5 8" NOTES: (1) FRAMING AT EDGE NAILING SHALL BE 3x OR WIDER AND NAILS SHALL BE STAGGERED. (3) WHERE PANELS ARE APPLIED TO BOTH FACES OF A WALL AND NAIL SPACING IS LESS THAN 6" ON CENTER, PANEL JOINTS SHALL BE OFFSET TO FALL ON DIFFERENT MEMBERS OR FRAMING SHALL BE 3x AND NAILS ON EACH SIDE STAGGERED. (4) PROVIDE MINIMUM 7" EMBEDMENT OF ANCHOR BOLTS INTO CONCRETE. (5) PANELS SHALL BE INSTALLED WITH THE LONG DIMENSION ACROSS THE STUDS OR STUDS SHALL BE SPACED AT 16" O.C. (6) 5/8" DIA. SIMPSON TITEN HD MODEL# THD62600H CAN BE USED IN LIEU OF J BOLT. (2) ALL PLYWOOD EDGES TO BE BLOCKED. USE 3x BLOCKING AND EDGE NAIL PLYWOOD TO BLOCK. (10) WOOD STRUCTURAL PANELS: DOC PS1 OR DOC PS2 AND DOUBLE STUDS ±1/2" EDGE DISTANCE FOR PLYWOOD B.N. ALL PANEL JOINT & SILL PLATE NAILING SHALL BE STAGGERED (11) 1 8" GAP AT ALL PLYWOOD PANEL EDGES REQUIRED. SILL CONNECTION(E.N. W/ COMMON NAILS ONLY)WALL LABEL DESCRIPTION OF SHEAR PANEL S H E A R W A L L S C H E D U L E DBL SIDED 12" OSB STRUCT. 1 BLOCKED W/ 8d NAILS @ 6" O.C. 1100 PLF 680 PLF 560 PLF 390 PLF SHEAR VALUE 260 PLF 12" OSB STRUCT. 1 BLOCKED W/ 8d NAILS @ 4" O.C. 15 32" OSB STRUCT. 1 BLOCKED W/ 8d NAILS @ 3" O.C. 15 32" OSB STRUCT. 1 BLOCKED W/ 8d NAILS @ 2" O.C. 15 32" OSB STRUCT. 1 BLOCKED W/ 8d NAILS @ 3" O.C. TOP PLATE CONNECTION 5 8" A.B. @ 40" O.C. W/ 2x 16d @ 6" O.C 5 8" A.B. @ 16" O.C. W/ 3x 16d @ 4" O.C SEE NOTE *(7) 5 8" A.B. @ 12" O.C. W/ 3x 3 8x7 SCREW @ 4" O.C. SEE NOTE *(7) 5 8" A.B. @ 16" O.C. W/ 3x 3 8x7 SCREW @ 6" O.C. SEE NOTE *(7) 5 8" A.B. @ 12" O.C. W/ 3x 3 8x7 SCREW @ 3" O.C. SEE NOTE *(7) A35 @ 24" O.C. OR LTP4 @ 24" O.C. A35 @ 16" O.C. OR LTP4 @ 16" O.C. A35 @ 12" O.C. OR LTP4 @ 12" O.C. A35 @ 12" O.C. OR LTP4 @ 12" O.C. A35 @ 6" O.C. OR LTP4 @ 6" O.C. 3 L= # ' 5 L= # ' 4 L= # ' 3 L= # ' 2 L= # ' 3X SILL PLATE A-2 X A-2 X 4 L=8'-0" HDU2 4X4 POST HDU2 4X4 POST 4X4 HDR (N) 2" X 6" R.R. @ 16" W/ MID SPAN WOOD SPECIES: DOUGLAS FIR-LARCH NO 1 NO ROOF EAVE ON THIS WALL 1/2" OSB EXT. GRADE PLYWD. W/ EXT. GRADE GLUE (P.I.32/16) LAY PLYWD. FACE GRAIN PER-PENDICULAR TO FRAMING AND NAIL W/ 8d @ 6",12" O/C 1/2" OSB EXT. GRADE PLYWD. W/ EXT. GRADE GLUE (P.I.32/16) LAY PLYWD. FACE GRAIN PER-PENDICULAR TO FRAMING AND NAIL W/ 8d @ 6",12" O/C 4X4 POST W/ ECC 4X4 POST W/ ECC 4X4 POST W/ ECC 9 3 - 2" X 8" CLG JOISTS 9 ---- (3) CEILING JOIST LAPPED W/ 16d@12"O.C. E.A. SIDE STAGER 12" 10 @16" O/C 2X4 CRIPPLES 3 - 2" X " CEILING JOISTS DBL TOP PLATE EACH SIDE. 2x SOLID BLK.'G. A35 EA SIDE PLAN HDR. PER 6x SOLID BLK.'G. 10 ---- (N) 2" X 6" R.R. @ 16" (N) 2" X 6" R.R. @ 16"(N) 2" X 6" R.R. @ 16" A A A WEEP SCREED TYP. 26 GA. GALV. STL. OR SEE PLAN & 7/8" MIN. STUCCO SHEARWALL SCHED. 2-#4 TOP& BOTT.24 " 3" 12" 2"X4" STUDS @ 16" o/c A. BOLTS @ 4'-0" O/C 5/8" Ø X 10" LONG (7" MIN. EMBEDMENT) 2"x4" P.T. SILL PLATE W/3"X3"X0.229" WASHERS 8" 4" CONCRETE SLAB 5 % 10-MIL VISQUENE VAPOR BARRIER 4" THICK BASE OF 1/2" CLEAN AGGREGATE (N) 2" X 6" R.R. @ 16 O.C." (N) 2" X 6" R.R. @ 16 O.C." (N) 2" X 6" R.R. @ 16 O.C." A NEW FOOTING (N) TO (E) SLAB ON GRADE DOWELING 5 ---- 5 ---- 5 ---- 4" CONC. SLAB ON GRADE W/#4 @ 16" O.C. BOTH WAYS AT OVER 2 LAYERS OF 10 MIL. VAPOR BARRIER OVER 4" THICK BASE OF 1/2" CRUSHED GRAVEL BASE. PRE-SATURATE TO A DEPTH OF 18". HOLDOWN @ NEW FOOTING MIN. NEW FOOTING 3" 8" 6-SDS 1/4"X2 1/2" 10-SDS 1/4"X2 1/2" 12" 12" 8" 8" 8"12"14-SDS 1/4"X2 1/2" NEW SLAB 4" X POST & DOUBLE NUT 5/8" Ø AL-THREAD ROD W/ 3" SQ.X 1/2" THK. PLATE WASHER 5/8" 5/8" 5/8" HDU2 HDU4 HDU5 EDGE DIST. PER PLAN SHEAR WALL PER PLAN SIMPSON HDU HOLDOWN ANCHOR DIA. FASTNERS EDGE DIST. EMBEDMENT RR 25720, ESR-2330 2X P.T. AA CF1 CF 1 CF 1 1 1 1 1 (N) 2" X 6" CJ @ 16" O.C. S-1 FOUNDATION PLAN, FRAMING PLAN ISSUES AND REVISIONS Computer File Project Name Description Project Number SHEET: Scale NO. 1. DATE 2. 3. CHECKBY CONSULTANT CONTACT: PROPOSED GARAGE CONVERSION INTO ADU SEAL: VERIFY MEASUREMENTS WITH CORRESPONDING COSTRUCTED OR EXISTING CONDITIONS PRIOR TO PROCEEDING WITH THE WORK, AND NOTIFY THE ARCHITECT IMMEDIATELY OF SIGNIFICANT DISCREPANCIES. FINISH ELEVATIONS REFERENCED ON ARCHITECTURAL DRAWINGS ARE DATUM ELEVATIONS ABOVE THE FINISH FLOOR ELEVATION. THE CONTRACTOR MUST COORDINATE DATUM-BASED ARCHITECTURAL ELEVATIONS SHOWN WITH SITE-SPECIFIC ELEVATIONS SHOWN ON CIVIL DRAWINGS. WALL DIMENSIONS SHOWN ARE TO FACE OF WALL FINISH UNLESS SPECIFICALLY NOTED OTHERWISE. 1432 N. BAKER ST. SANTA ANA, CA 92706 C&C Drafting Design Edgar Cortes & Commercial Residential Design 1100 E. Orangethorpe Ave. Ca. 92801 # 200w, Anaheim (562) 916 7505 (714) 813 6555 e_mail: ccdraftingdesign@yahoo.com OWNER: MRS. MINEL HERAS Mobile: (562) 547 4249 MRS. MOUREEN B. HERAS Mobile: (562) 547-4249 EMAIL: INPROPERBUENAPARK@GMAIL.COM A 2/05/2026 ROOF FRAMING PLAN, RELOCATE WATER HEATER, ELECTRICAL PANEL. CONCRETE SLAB DETAIL AND ROOF SHEATHING 01 /28/ 2026 DIGITAL STAMP