Loading...
HomeMy WebLinkAbout3401 S Harbor Blvd-sign - Plan© H G W A r c h i t e c t u r e , a l l r i g h t s r e s e r v e d . A n y u s e w it h o u t p e r m i s s i o n i s e x p r e s s l y p r o h i b i t e d . P l o t t e d 1955 Bacon Street. San Diego, CA 92107 Office 619 523 8487 www.hgwarchitecture.com Kaiser Permanente Buildings on Brand 3/ 1 8 / 2 0 2 6 1 1 : 0 8 : 1 5 A M 03/17/2026 Exterior Signage - Harbor MacArthur Medical Office Building | CAP030942 3401 S. Harbor Boulevard, Santa Ana, CA 92704 plan check resubmittal p r o j e c t d e s c r i p t i o n NEW SIGNAGE ON AN EXISTING 3-STORY MEDICAL OFFICE BUILDING v i c i n i t y m a p W MACARTHUR BLVD S H A R B O R B L V D W MOORE AVE W GARRY AVE S C R O D D Y W A Y S S H A N N O N S T PROJECT SITE p r o j e c t d a t a PROJECT ADDRESS: CONSTRUCTION TYPE: NUMBER OF STORIES: OCCUPANCY: BUILDING AREA: ASSESSOR'S PARCEL NUMBER: LEGAL DESCRIPTION: 3401 SOUTH HARBOR BOULEVARD SANTA ANA, CA 92704 TYPE II-A, FULLY SPRINKLERED 3 GROUP B - OFFICE BUILDING TOTAL AREA: 80,000 SF 414-262-08 P BK 38 LPG 13 PAR 2 P.M. 38-13, PAR.2 PRO OF PAR AND WILLIAMS 0 5' GRAPHIC SCALES: Issue Date 1/16" = 1'-0" 50' 1/8" = 1'-0" 1/4" = 1'-0" 1/2" = 1'-0" 3/4" = 1'-0" 1" = 1'-0"1-1/2" = 1'-0" 3" = 1'-0" 0 5'25'0 1' 12'0 1' 6'0 4'0 3'1'0 2'0 1' Chckd By Drwn By Scale Building ID: KP Proj. No. Permit No. Sheet SheetsOf Sheet Title Project Facility This document is the property of the Owner and is Project Architect Approval: Architect/Engineer Of Record: IF THIS SHEET IS NOT 30"x42" , IT IS A REDUCED PRINT - SCALE ACCORDINGLY National Facilities Services Post Office Box 12916 Oakland California 94604 not to be used without owner's written permission. Floor Lev:Section: Revisions By Appr. HGW Proj. No. © H G W A r c h i t e c t u r e , a l l r i g h t s r e s e r v e d . A n y u s e w i t ho u t p e r m i s s i o n i s e x p r e s s l y p r o h i b i t e d . P l o t t e d 1955 Bacon Street. San Diego, CA 92107 Office 619 523 8487 www.hgwarchitecture.com KAISER PERMANENTE BUILDINGS ON BRAND 12" = 1'-0" 3/ 1 8 / 2 0 2 6 1 1 : 0 8 : 1 5 A M 03/17/2026 Checker Author CAP030942 T001. TITLE SHEET 3401 South Harbor Boulevard, Santa Ana, CA 92704 pl a n c h e c k r e s u b m i t t a l 2441 EXTERIOR SIGNAGE - HARBOR-MAC ARTHUR i n d e xf i r e d e p t . n o t e s ALL REQUIRED PERMITS MUST BE OBTAINED FROM FIRE PLAN CHECK BEFORE THE BUILDING IS OCCUPIED. STANDPIPE SYSTEMS SHALL COMPLY WITH THE REQUIREMENTS OF CBC SEC. 905 PLANS FOR AUTOMATIC FIRE SPRINKLER SYSTEMS & CLASS I STANDPIPES MUST BE SUBMITTED AND APPROVED BY FIRE PLAN CHECK BEFORE THIS EQUIPMENT IS INSTALLED. VALVES CONTROLLING THE WATER SUPPLY FOR AUTOMATIC SPRINKLER SYSTEMS, PUMPS, TANKS, WATER LEVELS AND TEMPERATURES, CRITICAL AIR PRESSURES AND WATERFLOW SWITCHES ON ALL SPRINKLER SYSTEMS SHALL BE ELECTRICALLY SUPERVISED BY A LISTED FIRE ALARM CONTROL UNIT. (CBC SEC. 903.4) AN APPROVED AUDIBLE SPRINKLER FLOW ALARM SHALL BE PROVIDED ON THE EXTERIOR OF THE BUILDING IN AN APPROVED LOCATION PER (CBC SEC. 903.4.2). AN APPROVED AUDIBLE SPRINKLER FLOW ALARM TO ALERT THE OCCUPANTS SHALL BE INSTALLED IN THE INTERIORS IN A NORMALLY OCCUPIED LOCATION PER (CBC SEC. 904.3.4) PROVIDE TEMPORARY OR PERMANENT WATER SUPPLY FOR FIRE PROTECTION AS SOON AS COMBUSTIBLE MATERIALS ARRIVE ON SITE, AS REQUIRED AND APPROVED BY CORRESPONDANT FIRE DEPARTMENT FIRE PROTECTION, INCLUDING FIRE APPARATUS ACCESS ROADS AND WATER SUPPLIES FOR FIRE PROTECTION, SHALL BE INSTALLED AND MADE SERVICEABLE PRIOR TO AND DURING TIME OF CONSTRUCTION. (CFC 501.4) BUILDINGS UNDERGOING CONSTRUCTION ALTERATION OR DEMOLITION SHALL BE IN ACCORDANCE WITH CFC CHAPTER 33; CBC CHAPTER 33. ADDRESSES SHALL BE PROVIDED FOR ALL NEW AND EXISTING BUILDINGS IN A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. DECORATIVE MATERIALS SHALL BE MAINTAINED IN A FLAME RETARDANT CONDITION. (CODE REGS. TIT. 19, SEC. 3.08, 3.21, CFC 807) AT LEAST ONE FIRE EXTINGUISHER WITH A MINIMUM RATING OF 2-A-10B:C SHALL BE PROVIDED WITHIN 75 FEET MAXIMUM TRAVEL DISTANCE FOR EACH 6,000 S.F. OR PORTION THEREOF ON EACH FLOOR. (CFC 1002, UFC STANDARD 10-1, CAL. CODE REGS, TIT. 19, SEC. 3.29) AT LEAST ONE FIRE EXTINGUISHER WITH A MINIMUM RATING OF 2-A-10B:C SHALL BE PROVIDED WITHIN 75 FEET MAXIMUM TRAVEL DISTANCE PER CALIFORNIA CODE OF REGULATIONS, TITLE 19, DIVISION 1, SECTION 568, TABLE 2. (CFC 906.3) COMPLETE PLANS AND SPECIFICATIONS FOR ALL FIRE ALARM SYSTEMS, FIRE EXTINGUISHING SYSTEMS, INCLUDING AUTOMATIC SPRINKLERS AND WET DRY STANDPIPES, HALON SYSTEMS AND OTHER SPECIAL TYPES OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS, BASEMENT PIPE INLETS AND OTHER FIRE PROTECTION SYSTEMS AND APPURTENANCES THERETO SHALL BE SUBMITTED TO FIRE AND SAFETY FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. (CFC 901.2) FIRE EXTINGUISHING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH CBC SEC. 906 AND COMPLY WITH STANDARDS 9-1 AND 9-2. INSTALLATION OF FIRE ALARM SYSTEMS SHALL BE IN ACCORDANCE WITH CFC SEC. 907 WITH NOT LESS THAN ONE STANDPIPE FOR USE DURING CONSTRUCTION INSTALLED IN ACCORDANCE WITH CBC SEC. 3314 COMPLETE SITE SAFETY PLANS AND SPECIFICATIONS AT THE PROJECT SITE APPLICABLE THROUGHOUT ALL PHASES OF THE CONSTRUCTION, REPAIR, ALTERATION OR DEMOLITION WORK SHALL BE SUBMITTED TO FIRE AND LIFE SAFETY DEPARTMENT FOR REVIEW AND APPROVAL BUILDING PERMIT IS ISSUE CFC SEC. 3303 FIRE HYDRANT LOCATIONS SHALL COMPLY WITH FIRE AND LIFE SAFETY FPB POLICY F-96-01 FOR ON SITE FIRE HYDRANTS FIRE HYDRANTS SHALL BE IDENTIFIED BY THE INSTALLATION OF REFLECTIVE MARKERS 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. g o v e r n i n g c o d e s ALL WORK SHALL CONFORM TO THE CURRENT EDITIONS OF NATIONAL, STATE, AND LOCAL CODES, AND OTHER REGULATING AGENCIES WHICH HAVE AUTHORITY OVER ANY PORTION OF THE WORK. ALL CONTRACTORS AND SUBCONTRACTORS PERFORMING GENERAL CONSTRUCTION, MECHANICAL, ELECTRICAL, PLUMBING, OR RELATED WORK, SHALL COMPLY WITH APPLICABLE SECTIONS OF THE CODES THAT HAVE JURISDICTION. APPLICABLE CODES: 2022 CALIFORNIA BUILDING CODE (CBC) PART 1, PART 2, TITLE 24, CCR 2022 CALIFORNIA PLUMBING CODE PART 5, TITLE 24, CCR 2022 CALIFORNIA MECHANICAL CODE PART 4, TITLE 24, CCR 2022 CALIFORNIA FIRE CODE PART 9, TITLE 24, CCR 2022 NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS 2022 BUILDING STANDARDS ADMINISTRATIVE CODE PART 1, TITLE 24, CCR 2022 CALIFORNIA ELECTRICAL CODE PART 3, TITLE 24, CCR 2022 CALIFORNIA ENERGY CODE PART 6, TITLE 24, CCR 2022 CALIFORNIA GREEN BUILDING STANDARDS (CALGreen), PART 11, TITLE 24 CCR 2022 CALIFORNIA REFERENCED STANDARDS, PART 12, TITLE 24, CCR 2022 CALIFORNIA EXISTING BUILDING CODE (CEBC) 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN o w n e r / p e r m i t t e e : KAISER PERMANENTE 74 NORTH PASADENA AVENUE, 8TH FLOOR PASADENA, CA 91103 WORK: (626)372-4258 AGNES C. HERRERA (Agnes.C.Herrera@kp.org) - - - a r c h i t e c t : HGW ARCHITECTURE 1955 BACON STREET SAN DIEGO, CA 92107 WORK: 619.523.8485 RANDY HANNA (randy@hgwarchitecture.com) ERIC WENDLANDT (eric@hgwarchitecture.com) d i r e c t o r y m e p e n g i n e e r : IMEG 222 S. HARBOR BLVD., SUITE 800 ANAHEIM, CA 92805 WORK: (714) 507-1613 TIM PHAM (tim.g.pham@imegcorp.com) MIRA SOPHOCLIS GEORGY (mira.sophoclis-georgy@imegcorp.com) 3401 SOUTH HARBOR BOULEVARD SANTA ANA, CA 92704 TITLE T001. TITLE SHEET T301 SITE PLAN SIGNAGE & GRAPHICS SG200 EXTERIOR SIGNAGE - PAGES 1 THRU 4 SG201 EXTERIOR SIGNAGE - PAGES 5 THRU 8 SG202 EXTERIOR SIGNAGE - PAGES 9 THRU 12 SG203 EXTERIOR SIGNAGE - PAGE 13 ELECTRICAL ES001 ELECTRICAL COVERSHEET ES002 ELECTRICAL SPECIFICATIONS ES003 ELECTRICAL SPECIFICATIONS ES004 ELECTRICAL SPECIFICATIONS ES102 LEVEL 02-ELECTRICAL PLAN-OVERALL ES103 LEVEL 03-ELECTRICAL PLAN-OVERALL ES122 LEVEL 02-ENLARGED POWER PLAN ES123 LEVEL 03-ENLARGED POWER PLAN ES400 PARTIAL SINGLE LINE DIAGRAM, PANEL SCHEDULES, LOAD CALCULATIONS, & DETAILS No. Revisions Date 1 SD 06/05/2025 2 DD 07/03/2025 3 90% CD 08/15/2025 4 Plan Check Submittal 09/19/2025 12 Plan Check Resubmittal 02/25/2026 AREA PROVIDED FOR CITY APPROVED STAMPS EXISTING STRUCTURE LIMIT OF WORK (INTERIOR ONLY) TRUNCATED DOME TILES ST O P ST O P S T O P ST O P STOP STOP STOP ST O P STOP STOP g e n e r a l n o t e s IF THE CITY BUILDING INSPECTOR DETERMINES NON-COMPLIANCE WITH ANY ACCESSIBILITY PROVISIONS, A COMPLETE AND DETAILED REVISED PLANS CLEARLY SHOWING ALL EXISTING NON-COMPLYING CONDITIONS AND THE PROPOSED MODIFICATIONS TO MEET CURRENT ACCESSIBILITY REQUIREMENTS (INCLUDING SITE PLAN, FLOOR PLANS, DETAILS, ETC.) WILL BE SUBMITTED TO THE DEPARTMENT FOR REVIEW AND APPROVAL. s h e e t l e g e n d EXISTING ACCESSIBLE PATH OF TRAVEL INDICATES PUBLIC RIGHT OF WAY EXISTING ACCESSIBLE PARKING (E) ADA PARKING SIGNAGE ON POST W MACARTHUR BLVD S H A R B O R B L V D EXISTING SURFACE PARKING LOT EXISTING SURFACE PARKING LOT EXISTING SURFACE PARKING LOT EXISTING SURFACE PARKING LOT MAIN BLDG. ENTRY MAIN BLDG. ENTRY LIMIT OF WORK (INTERIOR ONLY) UNDER SEPARATE PERMIT 101125965, 20187568, 30149710 EXISTING 3 STORY BUILDING NEW LOGO BRANDING SIGN NEW LOGO BRANDING SIGN NEW LOGO BRANDING SIGN NEW LOGO BRANDING SIGN NEW WELCOME LETTERS 0 5' GRAPHIC SCALES: Issue Date 1/16" = 1'-0" 50' 1/8" = 1'-0" 1/4" = 1'-0" 1/2" = 1'-0" 3/4" = 1'-0" 1" = 1'-0" 1-1/2" = 1'-0" 3" = 1'-0" 0 5' 25'0 1' 12'0 1' 6'0 4'0 3'1'0 2'0 1' Chckd By Drwn By Scale Building ID: KP Proj. No. Permit No. Sheet SheetsOf Sheet Title Project Facility This document is the property of the Owner and is Project Architect Approval: Architect/Engineer Of Record: IF THIS SHEET IS NOT 30"x42" , IT IS A REDUCED PRINT - SCALE ACCORDINGLY National Facilities Services Post Office Box 12916 Oakland California 94604 not to be used without owner's written permission. Floor Lev: Section: Revisions By Appr. HGW Proj. No. © H G W A r c h i t e c t u r e , a l l r i g h t s r e s e r v e d . A n y u s e w i t ho u t p e r m i s s i o n i s e x p r e s s l y p r o h i b i t e d . P l o t t e d 1955 Bacon Street. San Diego, CA 92107 Office 619 523 8487 www.hgwarchitecture.com KAISER PERMANENTE BUILDINGS ON BRAND As indicated 3/ 1 8 / 2 0 2 6 1 1 : 0 8 : 1 7 A M 03/17/2026 Checker Author CAP030942 T301 SITE PLAN 3401 South Harbor Boulevard, Santa Ana, CA 92704 pl a n c h e c k r e s u b m i t t a l 2441 EXTERIOR SIGNAGE - HARBOR-MAC ARTHUR 0 15'30'1" = 30'-0"01 site accessibility plan k e y n o t e s No. Revisions Date 1 SD 06/05/2025 2 DD 07/03/2025 3 90% CD 08/15/2025 4 Plan Check Submittal 09/19/2025 12 Plan Check Resubmittal 02/25/2026 ELECTRICAL ABBREVIATION KEY AFF ABOVE FINISHED FLOOR C CONDUIT CO CONDUIT AND BOX ROUGH-IN ONLY (ROUGH-IN ONLY) GFI GROUND FAULT INTERRUPTER ABBR:DESCRIPTION: TYP TYPICAL UON UNLESS OTHERWISE NOTED 1. EXISTING CONDITIONS ARE SHOWN BASED ON INFORMATION OBTAINED FROM FIELD SURVEYS, EXISTING BUILDING DOCUMENTS. CONTRACTOR SHALL REVIEW EXISTING CONDITIONS AND REPORT CONFLICTS. 2. NOT ALL EXISTING EQUIPMENT, LUMINAIRES, AND CONDUIT ARE SHOWN. CONTRACTOR SHALL REVIEW EXISTING CONDITIONS AND REPORT CONFLICTS. 3. ELECTRICAL CONTRACTOR SHALL REVIEW EXISTING CONDITIONS TO VERIFY ACCESSIBILITY TO THE AREAS OF THEIR WORK INCLUDING WALLS, FLOOR, AND CEILINGS. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE CUTTING, REMOVAL, PATCHING, AND REINSTALLATION OF AFFECTED AREAS ASSOCIATED WITH THEIR WORK BY COORDINATING WITH THE GENERAL CONTRACTOR OR QUALIFIED CONTRACTOR. 4. WHERE EXISTING ELECTRICAL SYSTEMS ARE LOCATED IN AREAS THAT CONFLICT WITH NEW EQUIPMENT, PIPING, OR DUCTWORK TO BE INSTALLED, EACH CONTRACTOR SHALL EITHER ARRANGE NEW EQUIPMENT, CONDUIT, OR DUCTWORK IN SUCH A FASHION THAT IT DOES NOT CONFLICT WITH EXISTING SYSTEMS, OR REWORK EXISTING ELECTRICAL SYSTEMS TO ALLOW FOR INSTALLATION OF NEW EQUIPMENT, PIPING, OR DUCTWORK. ELECTRICAL RENOVATION NOTES: THESE NOTES APPLY TO ALL ELECTRICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED TO LIGHTING AND POWER 26 05 33 JUNCTION BOXJ ELECTRICAL SYMBOL LIST SYMBOL:TAG:SPEC SECTION:DESCRIPTION: PANEL '###'PANELBOARD -SURFACE MOUNT 26 05 33 ELECTRICAL CONNECTIONE E SWITCH SUBSCRIPTS: 3R= NEMA 3R WEATHERPROOF SWITCH ## J BRANCH CIRCUITS: LIGHTING, RECEPTACLES, CONTROLS, ETC. CONDUIT INSTALLATION SCHEDULE THE FOLLOWING SCHEDULE SHALL BE ADHERED TO UNLESS THEY CONSTITUTE A VIOLATION OF APPLICABLE CODES OR ARE NOTED OTHERWISE ON THE DRAW INGS. THE INSTALLATION OF RMC CONDUIT WILL BE PERMITTED IN PLACE OF ALL CONDUIT SPECIFIED IN THIS SCHEDULE. REFER TO CONDUIT AND BOXES SPECIFICATION 26 05 33 FOR ADDITIONAL INFORMATION. INSTALLATION TYPE FMC X EMT X BRANCH CIRCUIT SCHEDULE SYMBOL:DESCRIPTION: CONDUIT HOMERUN TO PANELBOARD. LETTER AND NUMERALS INDICATE ELECTRICAL PANEL AND CIRCUIT NUMBER. PANEL -CIRCUIT 2022 CALIFORNIA BUILDING STANDARDS ADMINISTRATIVE CODE CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 1 2022 CALIFORNIA BUILDING CODE (CBC) CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 2 (2021 INTERNATIONAL BUILDING CODE (IBC) W/ 2022 CALIFORNIA AMENDMENTS) 2022 CALIFORNIA ELECTRICAL CODE (CEC) CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 3 (2020 NATIONAL ELECTRICAL CODE (NEC) W/ 2022 CALIFORNIA AMENDMENTS) 2022 CALIFORNIA MECHANICAL CODE (CMC) CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 4 (2021 UNIFORM MECHANICAL CODE (UMC) W/ 2022 CALIFORNIA AMENDMENTS) 2022 CALIFORNIA PLUMBING CODE (CPC) CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 5 (2021 UNIFORM MECHANICAL CODE (UPC) W/ 2022 CALIFORNIA AMENDMENTS) 2022 CALIFORNIA ENERGY CODE CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 6 2022 CALIFORNIA FIRE CODE (CFC) CALIFORNIA CODES OF REGULATIONS (CRR) TITLE 24, PART 9 (2021 INTERNATIONAL FIRE CODE (IFC) W/ 2022 CALIFORNIA AMENDMENTS) 2022 CALIFORNIA EXISTING BUILDING CODE CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 10 (2021 INTERNATIONAL EXISTING BUILDING CODE (IEBC)) 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN) CALIFORNIA CODES OF REGULATIONS (CCR) TITLE 24, PART 11 2022 CALIFORNIA REFERENCED STANDARDS CODE CALIFORNIA DOE OF REGULATIONS (CCR) TITLE 24, PART 12 APPLICABLE CODES AND STANDARDS: 48 " M A X . 20" MAX. 44 " M A X . 20"-25" MAX. 48 " M A X . 15 " M I N . 48 " M A X . 46 " M A X . 10" MAX.10"-24" MAX. ADA STANDARDS -FRONT ACCESS ADA STANDARDS FOR ACCESSIBLE DESIGN INSTALL ABOVE COUNTER DEVICE AT 44" ABOVE FINISHED FLOOR. INSTALL ABOVE COUNTER DEVICE AT 40" ABOVE FINISHED FLOOR. INSTALL DEVICE AT 18" ABOVE FINISHED FLOOR. ADA STANDARDS -SIDE ACCESS INSTALL DEVICE AT 44" ABOVE FINISHED FLOOR. INSTALL DEVICE AT 42" ABOVE FINISHED FLOOR. ELECTRICAL CONTRACTORE.C. CONTRACTOR ABBREVIATION KEY ABBR:DESCRIPTION: VIEW KEY LINE TYPE AND TAG KEY: NEW WORK BY THIS CONTRACTOR (WIDE LINE) EXISTING TO REMAIN HALFTONING DOES NOT MODIFY SCOPE. 'TAG'-(E)TAGS WITH DASH 'E' INDICATES THE REFERENCED OBJECT IS EXISTING 'TAG'-(R)TAGS WITH DASH 'R' INDICATES THE REFERENCED OBJECT IS REMOVED TAG-1 UNDERLINED TAG INDICATES OBJECT IS IN-SCOPE. IF NEW, ADDITIONAL INFORMATION IS AVAILABLE IN A SCHEDULE, MATERIAL LIST, OR SYMBOL LIST INDICATES AN EXISTING SYSTEM'S POINT OF CONNECTION/REMOVAL PLAN OR DETAIL NUMBER PLAN OR DETAIL NAME PLAN OR DETAIL SCALE DETAIL REFERRED TO BY SECTION CUT SHEET DETAIL IS LOCATED ON NAME 1 VIEW NAME 1/8" = 1'-0" 1 M101 1 4 3 2 SIMSIM INDICATES SIMILAR DETAIL REFERENCED IN MULTIPLE LOCATIONS LEVEL NAME 10'-0"HEIGHT ABOVE PROJECT 0'-0" 1 KEYNOTE: INDICATES NOTE USED TO DESCRIBE ADDITIONAL INFORMATION ABOUT WORK REQUIRED, SPECIFIC TO THE SHEET AND/OR DETAIL NO R HT INDICATES DIRECTION OF TRUE NORTH T101 NEW EXISTING TO BE REMOVED (SHORT DASHED PATTERN) EXISTING (NARROW LINE PATTERN) SCOPE OF WORK NOTES: 1. DEMOLITION OF EXISTING EXTERIOR SIGNAGE AND INSTALLATION OF NEW EXTERIOR ILLUMINATED SIGNAGE. 1. THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE ADA STANDARDS FOR ACCESSIBLE DESIGN. REFER TO THE ADA GUIDELINES FOR ALL CONFIGURATION DETAILS ON THIS PAGE FOR ADDITIONAL INFORMATION. 2. CIRCUIT NUMBERS ARE SHOWN FOR CIRCUIT IDENTIFICATION. CIRCUITING SHALL AGREE WITH NUMBERING ON THE PANEL PROVIDED. COMMON NEUTRALS MAY NOT BE USED FOR BRANCH CIRCUITS. 3. FLUSH MOUNT ALL LIGHTING CONTROL DEVICES AT +42" FROM FLOOR (CENTERLINE DIMENSION), EXCEPT WHERE OTHERWISE NOTED. 4. FLUSH MOUNT ALL DUPLEX RECEPTACLES OUTLETS AT +18" FROM FLOOR (CENTERLINE DIMENSION), EXCEPT WHERE OTHERWISE NOTED. 5. CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CEILING MOUNTED DEVICES AND EQUIPMENT WITH LUMINAIRES, SPRINKLER, AND CEILING DIFFUSERS. CENTER ALL DEVICES IN CEILING TILE PATTERN. OCCUPANCY/VACANCY SENSORS SHALL BE LOCATED NO CLOSER THAN 3 FEET TO AN AIR SUPPLY DIFFUSER OR RETURN GRILLE. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE EXPENSE OF THIS CONTRACTOR. ALL CONDUITS THROUGH W ALLS SHALL BE GROUTED OR SEALED INTO OPENINGS. 7. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO THE WALLS, FLOORS, AND CEILINGS. THE CONTRACTOR WHOSE WORK CAUSES DAMAGE IS RESPONSIBLE FOR PATCHING TO MATCH ORIGINAL CONSTRUCTION, FIRE RATING, AND FINISH. 8. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL AND OTHER ELECTRICAL PLANS FOR EXACT LOCATIONS OF ALL CEILING MOUNTED DEVICES, OTHER THAN SPRINKLERS. 9. ELECTRICAL IDENTIFICATION. REFER TO SPECIFICATION SECTION 26 05 53 FOR COLOR/LABEL REQUIREMENTS FOR CONDUIT, BOX, CABLE/WIRE, AND EQUIPMENT. ELECTRICAL INSTALLATION NOTES: TE OLIRFFOAC LANRP E 23191 STA ER REGIST ED INA N REENIGE FO OISSE E AICLCERTL Exp. 06/30/26 MIRASOPHOCLISGEORGY IMEG RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAW ING AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG AND SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG. ©2024 IMEG CONSULTANTS CORP. REF. SCALE IN INCHES 0 1 2 3 222 S. HARBOR BOULEVARD SUITE 800 ANAHEIM, CA 92805 P: 714.490.5555 F: 714.490.5560 The FUTURE. Built Smarter www.imegcorp.com PROJECT #24007312.00 0 5' GRAPHIC SCALES: Issue Date 1/16" = 1'-0" 50' 1/8" = 1'-0"1/4" = 1'-0"1/2" = 1'-0"3/4" = 1'-0"1" = 1'-0"1-1/2" = 1'-0"3" = 1'-0" 0 5'25' 0 1'12' 0 1'6' 0 4' 0 3'1'0 2' 0 1' Chckd By Drwn By Scale Building ID: KP Proj. No. Permit No. Sheet SheetsOf Sheet Title Project Facility This document is the property of the Owner and is Project Architect Approval: Architect/Engineer Of Record: IF THIS SHEET IS NOT 30"x42" , IT IS A REDUCED PRINT - SCALE ACCORDINGLY National Facilities Services Post Office Box 12916 Oakland California 94604 not to be used without owner's written permission. Floor Lev:Section: HGW Proj. No. © A R C H I T E C T S h a n n a g a b r i e l w e l l s , a l l r i g h t s r e s e r v ed . A n y u s e w i t h o u t p e r m i s s i o n i s e x p r e s s l y p r o h i b i t ed . P l o t t e d CAP029271 1955 Bacon Street. San Diego, CA 92107 Office 619 523 8487 www.hgwarchitecture.com PROJECT #24007312.00 Revisions By Appr. KAISER HARBOR MACARTHUR MOB EXTERIOR SIGNAGE KAISER PERMANENTE HARBOR MACARTHUR MOB As indicated 1/ 2 3 / 2 0 2 6 1 2 : 4 5 : 5 2 P M 01/23/2026 MG CL ES001 ELECTRICAL COVERSHEET 3401 South Harbor Boulevard, Santa Ana, CA 92704 10 0 % C D S E T 2441 ELECTRICAL SHEET INDEX ES001 ELECTRICAL COVERSHEET ES002 ELECTRICAL SPECIFICATIONS ES003 ELECTRICAL SPECIFICATIONS ES004 ELECTRICAL SPECIFICATIONS ES102 LEVEL 02 - ELECTRICAL PLAN - OVERALL ES103 LEVEL 03 - ELECTRICAL PLAN - OVERALL ES122 LEVEL 02 - ENLARGED POWER PLAN ES123 LEVEL 03 - ENLARGED POWER PLAN ES400 PARTIAL SINGLE LINE DIAGRAM, PANEL SCHEDULES, LOAD CALCULATIONS, & DETAILS GRAND TOTAL: 9 No. Revisions Date pl a n c h e c k s u b m i t t a l TE OLIRFFOAC LANRP E 23191 STA ER REGIST ED INA N REENIGE FO OISSE E AICLCERTL Exp. 06/30/26 MIRASOPHOCLISGEORGY IMEG RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAW ING AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG AND SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG. ©2024 IMEG CONSULTANTS CORP. REF. SCALE IN INCHES 0 1 2 3 222 S. HARBOR BOULEVARD SUITE 800 ANAHEIM, CA 92805 P: 714.490.5555 F: 714.490.5560 The FUTURE. Built Smarter www.imegcorp.com PROJECT #24007312.00 0 5' GRAPHIC SCALES: Issue Date 1/16" = 1'-0" 50' 1/8" = 1'-0"1/4" = 1'-0"1/2" = 1'-0"3/4" = 1'-0"1" = 1'-0"1-1/2" = 1'-0"3" = 1'-0" 0 5'25' 0 1'12' 0 1'6' 0 4' 0 3'1'0 2' 0 1' Chckd By Drwn By Scale Building ID: KP Proj. No. Permit No. Sheet SheetsOf Sheet Title Project Facility This document is the property of the Owner and is Project Architect Approval: Architect/Engineer Of Record: IF THIS SHEET IS NOT 30"x42" , IT IS A REDUCED PRINT - SCALE ACCORDINGLY National Facilities Services Post Office Box 12916 Oakland California 94604 not to be used without owner's written permission. Floor Lev: Section: HGW Proj. No. © A R C H I T E C T S h a n n a g a b r i e l w e l l s , a l l r i g h t s r e s e r v ed . A n y u s e w i t h o u t p e r m i s s i o n i s e x p r e s s l y p r o h i b i t ed . P l o t t e d CAP029271 1955 Bacon Street. San Diego, CA 92107 Office 619 523 8487 www.hgwarchitecture.com PROJECT #24007312.00 Revisions By Appr. KAISER HARBOR MACARTHUR MOB EXTERIOR SIGNAGE KAISER PERMANENTE HARBOR MACARTHUR MOB 1/ 2 3 / 2 0 2 6 1 2 : 4 5 : 5 2 P M 01/23/2026 MG CL ES002 ELECTRICAL SPECIFICATIONS 3401 South Harbor Boulevard, Santa Ana, CA 92704 10 0 % C D S E T 2441 SECTION 26 05 00 -BASIC ELECTRICAL REQUIREMENTS PART 1 -GENERAL 1.1 SECTION INCLUDES A.REQUIREMENTS APPLICABLE TO ALL DIVISION 26 SECTIONS. ALSO REFER TO DIVISION 1 - GENERAL REQUIREMENTS B.ALL MATERIALS AND INSTALLATION METHODS SHALL CONFORM TO THE APPLICABLE STANDARDS, GUIDELINES AND CODES REFERENCED HEREIN AND WITHIN EACH SPECIFICATION SECTION. 1.2 REFERENCES A.B.CEC CALIFORNIA ELECTRICAL CODE C.CCR CALIFORNIA CODE OF REGULATION D.CBC CALIFORNIA BUILDING CODE E.CFC CALIFORNIA FIRE CODE F.CMC CALIFORNIA MECHANICAL CODE G.CPC CALIFORNIA PLUMBING CODE 1.3 SCOPE OF WORK A.THIS SPECIFICATION AND THE ASSOCIATED DRAWINGS GOVERN FURNISHING, INSTALLING, TESTING AND PLACING INTO SATISFACTORY OPERATION THE ELECTRICAL SYSTEMS. B.THE CONTRACTOR SHALL FURNISH AND INSTALL ALL NEW MATERIALS AS INDICATED ON THE DRAWINGS, AND/OR IN THESE SPECIFICATIONS, AND ALL ITEMS REQUIRED TO MAKE THE PORTION OF THE ELECTRICAL WORK A FINISHED AND W ORKING SYSTEM. C.DESCRIPTION OF SYSTEMS SHALL BE AS FOLLOWS: 1.ELECTRICAL POWER SYSTEM TO AND INCLUDING LUMINAIRES,, DEVICES, ETC. 2.REMOVAL WORK AND/OR RELOCATION AND REUSE OF EXISTING SYSTEMS AND EQUIPMENT. 3.TELECOMMUNICATIONS ROUGH-IN, AS SHOWN ON DRAWINGS, FOR INSTALLATION OF TELECOMMUNICATIONS EQUIPMENT BY OTHERS UNDER SEPARATE CONTRACT. 4.FURNISH AND INSTALL FIRESTOPPING SYSTEMS FOR PENETRATIONS OF FIRE-RATED CONSTRUCTION ASSOCIATED WITH THIS CONTRACTOR'S WORK. D.WORK NOT INCLUDED: 1.TELECOMMUNICATIONS CABLING WILL BE BY KPIT, IN RACEWAYS AND CONDUITS FURNISHED AND INSTALLED AS PART OF THE ELECTRICAL W ORK. 1.4 WORK SEQUENCE A.ALL WORK THAT WILL PRODUCE EXCESSIVE NOISE OR INTERFERENCE WITH NORMAL BUILDING OPERATIONS, AS DETERMINED BY THE OWNER, SHALL BE SCHEDULED WITH THE OWNER. IT MAY BE NECESSARY TO SCHEDULE SUCH WORK DURING UNOCCUPIED HOURS. THE OWNER RESERVES THE RIGHT TO DETERMINE WHEN RESTRICTED CONSTRUCTION HOURS ARE REQUIRED. 1.5 QUALITY ASSURANCE A.CONTRACTOR'S RESPONSIBILITY PRIOR TO SUBMITTING PRICING/BID DATA: 1.THE CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTING COMPLETE AND OPERATING SYSTEMS. THE CONTRACTOR ACKNOWLEDGES AND UNDERSTANDS THAT THE CONTRACT DOCUMENTS ARE A TWO-DIMENSIONAL REPRESENTATION OF A THREE- DIMENSIONAL OBJECT, SUBJECT TO HUMAN INTERPRETATION. THIS REPRESENTATION MAY INCLUDE IMPERFECT DATA, INTERPRETED CODES, UTILITY GUIDES, THREE- DIMENSIONAL CONFLICTS, AND REQUIRED FIELD COORDINATION ITEMS. SUCH DEFICIENCIES CAN BE CORRECTED WHEN IDENTIFIED PRIOR TO ORDERING MATERIAL AND STARTING INSTALLATION. THE CONTRACTOR AGREES TO CAREFULLY STUDY AND COMPARE THE INDIVIDUAL CONTRACT DOCUMENTS AND REPORT AT ONCE IN WRITING TO THE ARCHITECT/ENGINEER ANY DEFICIENCIES THE CONTRACTOR MAY DISCOVER. THE CONTRACTOR FURTHER AGREES TO REQUIRE EACH SUBCONTRACTOR TO LIKEWISE STUDY THE DOCUMENTS AND REPORT AT ONCE ANY DEFICIENCIES DISCOVERED. 2.THE CONTRACTOR SHALL RESOLVE ALL REPORTED DEFICIENCIES WITH THE ARCHITECT/ENGINEER PRIOR TO AWARDING ANY SUBCONTRACTS, ORDERING MATERIAL, OR STARTING ANY WORK WITH THE CONTRACTOR'S OWN EMPLOYEES. ANY WORK PERFORMED PRIOR TO RECEIPT OF INSTRUCTIONS FROM THE ARCHITECT/ENGINEER WILL BE DONE AT THE CONTRACTOR'S RISK. B.QUALIFICATIONS: 1.ONLY PRODUCTS OF REPUTABLE MANUFACTURERS AS DETERMINED BY THE ARCHITECT/ENGINEER ARE ACCEPTABLE. 2.ALL CONTRACTORS AND SUBCONTRACTORS SHALL EMPLOY ONLY WORKMEN WHO ARE SKILLED IN THEIR TRADES. AT ALL TIMES, THE NUMBER OF APPRENTICES AT THE JOB SITE SHALL BE LESS THAN OR EQUAL TO THE NUMBER OF JOURNEYMEN AT THE JOB SITE. C.COMPLIANCE WITH CODES, LAWS, ORDINANCES: 1.IF THERE IS A DISCREPANCY BETWEEN THE CODES AND REGULATIONS AND THESE SPECIFICATIONS, THE ARCHITECT/ENGINEER SHALL DETERMINE THE METHOD OR EQUIPMENT USED. 2.IF THE CONTRACTOR NOTES, AT THE TIME OF BIDDING, THAT ANY PARTS OF THE DRAWINGS OR SPECIFICATIONS DO NOT COMPLY WITH THE CODES OR REGULATIONS, CONTRACTOR SHALL INFORM THE ARCHITECT/ENGINEER IN W RITING, REQUESTING A CLARIFICATION. IF THERE IS INSUFFICIENT TIME FOR THIS PROCEDURE, CONTRACTOR SHALL SUBMIT WITH THE PROPOSAL A SEPARATE PRICE TO MAKE THE SYSTEM COMPLY WITH THE CODES AND REGULATIONS. 3.ALL CHANGES TO THE SYSTEM MADE AFTER THE LETTING OF THE CONTRACT TO COMPLY WITH CODES OR THE REQUIREMENTS OF THE INSPECTOR, SHALL BE MADE BY THE CONTRACTOR WITHOUT COST TO THE OWNER. D.EXAMINATION OF DRAWINGS: 1.THE DRAWINGS FOR THE ELECTRICAL WORK ARE COMPLETELY DIAGRAMMATIC, INTENDED TO CONVEY THE SCOPE OF THE WORK AND TO INDICATE THE GENERAL ARRANGEMENTS AND LOCATIONS OF EQUIPMENT, OUTLETS, ETC., AND THE APPROXIMATE SIZES OF EQUIPMENT. 2.CONTRACTOR SHALL DETERMINE THE EXACT LOCATIONS OF EQUIPMENT AND ROUGH- INS, AND THE EXACT ROUTING OF RACEWAYS TO BEST FIT THE LAYOUT OF THE JOB. CONDUIT ENTRY POINTS FOR ELECTRICAL EQUIPMENT INCLUDING, BUT NOT LIMITED TO, PANELBOARDS SHALL BE DETERMINED BY THE CONTRACTOR UNLESS NOTED IN THE CONTRACT DOCUMENTS. 3.SCALING OF THE DRAWINGS WILL NOT BE SUFFICIENT OR ACCURATE FOR DETERMINING THESE LOCATIONS. 4.WHERE JOB CONDITIONS REQUIRE REASONABLE CHANGES IN ARRANGEMENTS AND LOCATIONS, SUCH CHANGES SHALL BE MADE BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. 5.BECAUSE OF THE SCALE OF THE DRAWINGS, CERTAIN BASIC ITEMS, SUCH AS JUNCTION BOXES, PULL BOXES, CONDUIT FITTINGS, ETC., MAY NOT BE SHOWN, BUT WHERE REQUIRED BY OTHER SECTIONS OF THE SPECIFICATIONS OR REQUIRED FOR PROPER INSTALLATION OF THE WORK, SUCH ITEMS SHALL BE FURNISHED AND INSTALLED. 6.IF AN ITEM IS EITHER SHOWN ON THE DRAWINGS OR CALLED FOR IN THE SPECIFICATIONS, IT SHALL BE INCLUDED IN THIS CONTRACT. 7.THE CONTRACTOR SHALL DETERMINE QUANTITIES AND QUALITY OF MATERIAL AND EQUIPMENT REQUIRED FROM THE DOCUMENTS. WHERE DISCREPANCIES ARISE BETWEEN DRAWINGS, SCHEDULES AND/OR SPECIFICATIONS, THE GREATER AND BETTER-QUALITY NUMBER SHALL GOVERN. 8.WHERE USED IN ELECTRICAL DOCUMENTS THE WORD "FURNISH" SHALL MEAN SUPPLY FOR USE, THE WORD "INSTALL" SHALL MEAN CONNECT UP COMPLETE AND READY FOR OPERATION, AND THE WORD "PROVIDE" SHALL MEAN TO SUPPLY FOR USE AND CONNECT UP COMPLETE AND READY FOR OPERATION. 9.ANY ITEM LISTED AS FURNISHED SHALL ALSO BE INSTALLED UNLESS OTHERWISE NOTED. 10.ANY ITEM LISTED AS INSTALLED SHALL ALSO BE FURNISHED UNLESS OTHERWISE NOTED. E.ELECTRONIC MEDIA/FILES: 1.CONSTRUCTION DRAWINGS FOR THIS PROJECT HAVE BEEN PREPARED UTILIZING REVIT. 2.CONTRACTORS AND SUBCONTRACTORS MAY REQUEST ELECTRONIC MEDIA FILES OF THE CONTRACT DRAWINGS AND/OR COPIES OF THE SPECIFICATIONS. SPECIFICATIONS WILL BE PROVIDED IN PDF FORMAT. 3.UPON REQUEST FOR ELECTRONIC MEDIA, THE CONTRACTOR SHALL COMPLETE AND RETURN A SIGNED "ELECTRONIC FILE TRANSMITTAL" FORM PROVIDED BY IMEG. 4.IF THE INFORMATION REQUESTED INCLUDES FLOOR PLANS PREPARED BY OTHERS, THE CONTRACTOR WILL BE RESPONSIBLE FOR OBTAINING APPROVAL FROM THE APPROPRIATE DESIGN PROFESSIONAL FOR USE OF THAT PART OF THE DOCUMENT. 5.THE ELECTRONIC CONTRACT DOCUMENTS CAN BE USED FOR PREPARATION OF SHOP DRAWINGS AND AS-BUILT DRAWINGS ONLY. THE INFORMATION MAY NOT BE USED IN WHOLE OR IN PART FOR ANY OTHER PROJECT. 6.THE DRAWINGS PREPARED BY IMEG FOR BIDDING PURPOSES MAY NOT BE USED DIRECTLY FOR DUCTWORK LAYOUT DRAWINGS OR COORDINATION DRAWINGS. 7.THE INFORMATION IS PROVIDED TO EXPEDITE THE PROJECT AND ASSIST THE CONTRACTOR WITH NO GUARANTEE BY IMEG AS TO THE ACCURACY OR CORRECTNESS OF THE INFORMATION PROVIDED. IMEG ACCEPTS NO RESPONSIBILITY OR LIABILITY FOR THE CONTRACTOR'S USE OF THESE DOCUMENTS. F.FIELD MEASUREMENTS: 1.VERIFY ALL PERTINENT DIMENSIONS AT THE JOB SITE BEFORE ORDERING ANY CONDUIT, CONDUCTORS, WIREWAYS, BUS DUCT, FITTINGS, ETC. 1.6 SUBMITTALS A.SUBMITTALS SHALL BE REQUIRED FOR THE FOLLOWING ITEMS SHOWN ON DRAWINGS AND FOR ADDITIONAL ITEMS WHERE REQUIRED ELSEWHERE IN THE SPECIFICATIONS. 1.SUBMITTALS LIST: REFERENCED SPECIFICATION SECTION SUBMITTAL ITEM 26 05 13 WIRE AND CABLE 26 05 26 GROUNDING AND BONDING 26 05 33 CONDUIT AND BOXES 26 05 53 ELECTRICAL IDENTIFICATION 26 09 33 LIGHTING CONTROL SYSTEM 26 27 26 WIRING DEVICES 26 51 19 LED LIGHTING B.GENERAL SUBMITTAL PROCEDURES: IN ADDITION TO THE PROVISIONS OF DIVISION 1, THE FOLLOWING ARE REQUIRED: 1.TRANSMITTAL: EACH TRANSMITTAL SHALL INCLUDE THE FOLLOWING: a.DATE b.PROJECT TITLE AND NUMBER c.CONTRACTOR'S NAME AND ADDRESS d.DIVISION OF WORK (E.G., ELECTRICAL, PLUMBING, HEATING, VENTILATING, ETC.) e.DESCRIPTION OF ITEMS SUBMITTED AND RELEVANT SPECIFICATION NUMBER f.NOTATIONS OF DEVIATIONS FROM THE CONTRACT DOCUMENTS g.OTHER PERTINENT DATA 2.SUBMITTAL COVER SHEET: EACH SUBMITTAL SHALL INCLUDE A COVER SHEET CONTAINING: a.DATE b.PROJECT TITLE AND NUMBER c.ARCHITECT/ENGINEER d.CONTRACTOR AND SUBCONTRACTORS' NAMES AND ADDRESSES e.SUPPLIER AND MANUFACTURER'S NAMES AND ADDRESSES f.DIVISION OF WORK (E.G., ELECTRICAL, PLUMBING, HEATING, VENTILATING, ETC.) g.DESCRIPTION OF ITEM SUBMITTED (USING PROJECT NOMENCLATURE) AND RELEVANT SPECIFICATION NUMBER h.NOTATIONS OF DEVIATIONS FROM THE CONTRACT DOCUMENTS i.OTHER PERTINENT DATA j.PROVIDE SPACE FOR CONTRACTOR'S REVIEW STAMPS 3.COMPOSITION: a.SUBMITTALS SHALL BE SUBMITTED USING SPECIFICATION SECTIONS AND THE PROJECT NOMENCLATURE FOR EACH ITEM. b.INDIVIDUAL SUBMITTAL PACKAGES SHALL BE PREPARED FOR ITEMS IN EACH SPECIFICATION SECTION. ALL ITEMS WITHIN A SINGLE SPECIFICATION SECTION SHALL BE PACKAGED TOGETHER WHERE POSSIBLE. AN INDIVIDUAL SUBMITTAL MAY CONTAIN ITEMS FROM MULTIPLE SPECIFICATIONS SECTIONS IF THE ITEMS ARE INTIMATELY LINKED (E.G., PUMPS AND MOTORS). c.ALL SETS SHALL CONTAIN AN INDEX OF THE ITEMS ENCLOSED WITH A GENERAL TOPIC DESCRIPTION ON THE COVER. 4.CONTENT: SUBMITTALS SHALL INCLUDE ALL FABRICATION, ERECTION, LAYOUT, AND SETTING DRAWINGS; MANUFACTURERS' STANDARD DRAWINGS; SCHEDULES; DESCRIPTIVE LITERATURE, CATALOGS AND BROCHURES; PERFORMANCE AND TEST DATA; WIRING AND CONTROL DIAGRAMS; DIMENSIONS; SHIPPING AND OPERATING WEIGHTS; SHIPPING SPLITS; SERVICE CLEARANCES; AND ALL OTHER DRAWINGS AND DESCRIPTIVE DATA OF MATERIALS OF CONSTRUCTION AS MAY BE REQUIRED TO SHOW THAT THE MATERIALS, EQUIPMENT OR SYSTEMS AND THE LOCATION THEREOF CONFORM TO THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. 5.CONTRACTOR'S APPROVAL STAMP: a.THE CONTRACTOR SHALL THOROUGHLY REVIEW AND APPROVE ALL SHOP DRAWINGS BEFORE SUBMITTING THEM TO THE ARCHITECT/ENGINEER. THE CONTRACTOR SHALL STAMP, DATE AND SIGN EACH SUBMITTAL CERTIFYING IT HAS BEEN REVIEWED. b.UNSTAMPED SUBMITTALS WILL BE REJECTED. c.THE CONTRACTOR'S REVIEW SHALL INCLUDE, BUT NOT BE LIMITED TO, VERIFICATION OF THE FOLLOWING: 1)ONLY APPROVED MANUFACTURERS ARE USED. 2)ADDENDA ITEMS HAVE BEEN INCORPORATED. 3)CATALOG NUMBERS AND OPTIONS MATCH THOSE SPECIFIED. 4)PERFORMANCE DATA MATCHES THAT SPECIFIED. 5)ELECTRICAL CHARACTERISTICS AND LOADS MATCH THOSE SPECIFIED. 6)EQUIPMENT CONNECTION LOCATIONS, SIZES, CAPACITIES, ETC. HAVE BEEN COORDINATED WITH OTHER AFFECTED TRADES. 7)DIMENSIONS AND SERVICE CLEARANCES ARE SUITABLE FOR THE INTENDED LOCATION. 8)EQUIPMENT DIMENSIONS ARE COORDINATED WITH SUPPORT STEEL, HOUSEKEEPING PADS, OPENINGS, ETC. 9)CONSTRUCTABILITY ISSUES ARE RESOLVED (E.G., WEIGHTS AND DIMENSIONS ARE SUITABLE FOR GETTING THE ITEM INTO THE BUILDING AND INTO PLACE, SINKS FIT INTO COUNTERTOPS, ETC.). d.THE CONTRACTOR SHALL REVIEW, STAMP AND APPROVE ALL SUBCONTRACTORS' SUBMITTALS AS DESCRIBED ABOVE. e.THE CONTRACTOR'S APPROVAL STAMP IS REQUIRED ON ALL SUBMITTALS. APPROVAL WILL INDICATE THE CONTRACTOR'S REVIEW OF ALL MATERIAL AND A COMPLETE UNDERSTANDING OF EXACTLY WHAT IS TO BE FURNISHED. CONTRACTOR SHALL CLEARLY MARK ALL DEVIATIONS FROM THE CONTRACT DOCUMENTS ON ALL SUBMITTALS. IF DEVIATIONS ARE NOT MARKED BY THE CONTRACTOR, THEN THE ITEM SHALL BE REQUIRED TO MEET ALL DRAWING AND SPECIFICATION REQUIREMENTS. 6.SUBMITTAL IDENTIFICATION AND MARKINGS: a.THE CONTRACTOR SHALL CLEARLY MARK EACH ITEM WITH THE SAME NOMENCLATURE APPLIED ON THE DRAWINGS OR IN THE SPECIFICATIONS. b.THE CONTRACTOR SHALL CLEARLY INDICATE THE SIZE, FINISH, MATERIAL, ETC. c.WHERE MORE THAN ONE MODEL IS SHOWN ON A MANUFACTURER'S SHEET, THE CONTRACTOR SHALL CLEARLY INDICATE EXACTLY WHICH ITEM AND WHICH DATA IS INTENDED. d.ALL MARKS AND IDENTIFICATIONS ON THE SUBMITTALS SHALL BE UNAMBIGUOUS. 7.SCHEDULE SUBMITTALS TO EXPEDITE THE PROJECT. COORDINATE SUBMISSION OF RELATED ITEMS. 8.IDENTIFY VARIATIONS FROM THE CONTRACT DOCUMENTS AND PRODUCT OR SYSTEM LIMITATIONS THAT MAY BE DETRIMENTAL TO THE SUCCESSFUL PERFORMANCE OF THE COMPLETED WORK. 9.REPRODUCTION OF CONTRACT DOCUMENTS ALONE IS NOT ACCEPTABLE FOR SUBMITTALS. 10.INCOMPLETE SUBMITTALS WILL BE REJECTED WITHOUT REVIEW. PARTIAL SUBMITTALS WILL ONLY BE REVIEWED WITH PRIOR APPROVAL FROM THE ARCHITECT/ENGINEER. 11.SUBMITTALS NOT REQUIRED BY THE CONTRACT DOCUMENTS MAY BE RETURNED WITHOUT REVIEW. 12.THE ARCHITECT/ENGINEER'S RESPONSIBILITY SHALL BE TO REVIEW ONE SET OF SHOP DRAWING SUBMITTALS FOR EACH PRODUCT. IF THE FIRST SUBMITTAL IS INCOMPLETE OR DOES NOT COMPLY WITH THE DRAWINGS AND/OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE TO BEAR THE COST FOR THE ARCHITECT/ENGINEER TO RECHECK AND HANDLE THE ADDITIONAL SHOP DRAWING SUBMITTALS. 13.SUBMITTALS SHALL BE REVIEWED AND APPROVED BY THE ARCHITECT/ENGINEER BEFORE RELEASING ANY EQUIPMENT FOR MANUFACTURE OR SHIPMENT. 14.CONTRACTOR'S RESPONSIBILITY FOR ERRORS, OMISSIONS OR DEVIATION FROM THE CONTRACT DOCUMENTS IN SUBMITTALS IS NOT RELIEVED BY THE ARCHITECT/ENGINEER'S APPROVAL. 15.SCHEDULE SHALL ALLOW FOR ADEQUATE TIME TO PERFORM ORDERLY AND PROPER REVIEW OF SUBMITTALS, INCLUDING TIME FOR CONSULTANTS AND OWNER IF REQUIRED, AND RESUBMITTALS BY CONTRACTOR IF NECESSARY, AND TO CAUSE NO DELAY IN WORK OR IN ACTIVITIES OF OWNER OR OTHER CONTRACTORS. a.ALLOW AT LEAST TWO WEEKS FOR ARCHITECT'S/ENGINEER'S REVIEW AND PROCESSING OF EACH SUBMITTAL, EXCLUDING MAILING. 16.ARCHITECT/ENGINEER RESERVES THE RIGHT TO WITHHOLD ACTION ON A SUBMITTAL WHICH, IN THE ARCHITECT/ENGINEER'S OPINION, REQUIRES COORDINATION WITH OTHER SUBMITTALS UNTIL RELATED SUBMITTALS ARE RECEIVED. THE ARCHITECT/ENGINEER WILL NOTIFY THE CONTRACTOR, IN WRITING, WHEN THEY EXERCISE THIS RIGHT. 1.7 CHANGE ORDERS A.A DETAILED MATERIAL AND LABOR TAKEOFF SHALL BE PREPARED FOR EACH CHANGE ORDER, ALONG WITH LABOR RATES AND MARKUP PERCENTAGES. CHANGE ORDERS SHALL BE BROKEN DOWN BY SHEET OR ASSOCIATED INDIVIDUAL LINE ITEM INDICATED IN THE CHANGE ASSOCIATED NARRATIVE, WHICHEVER PROVIDES THE MOST DETAILED BREAKDOWN. CHANGE ORDERS WITH INADEQUATE BREAKDOWN WILL BE REJECTED. B.ITEMIZED PRICING WITH UNIT COST SHALL BE PROVIDED FROM ALL DISTRIBUTORS AND ASSOCIATED SUBCONTRACTORS. C.CHANGE ORDER WORK SHALL NOT PROCEED UNTIL AUTHORIZED. 1.8 PRODUCT DELIVERY, STORAGE, HANDLING AND MAINTENANCE A.EXERCISE CARE IN TRANSPORTING AND HANDLING TO AVOID DAMAGE TO MATERIALS. STORE MATERIALS ON THE SITE TO PREVENT DAMAGE. B.KEEP ALL MATERIALS CLEAN, DRY AND FREE FROM DAMAGING ENVIRONMENTS. C.CONTRACTOR IS RESPONSIBLE FOR MOVING EQUIPMENT INTO THE BUILDING AND/OR SITE. CONTRACTOR SHALL REVIEW SITE PRIOR TO BID FOR PATH LOCATIONS AND ANY REQUIRED BUILDING MODIFICATIONS TO ALLOW MOVEMENT OF EQUIPMENT. CONTRACTOR SHALL COORDINATE THE WORK WITH OTHER TRADES. 1.9 WARRANTY A.PROVIDE ONE-YEAR WARRANTY FOR ALL FIXTURES, EQUIPMENT, MATERIALS, AND WORKMANSHIP. B.THE WARRANTY PERIOD FOR ALL WORK IN THIS SPECIFICATION DIVISION SHALL COMMENCE ON THE DATE OF SUBSTANTIAL COMPLETION OR SUCCESSFUL SYSTEM PERFORMANCE WHICHEVER OCCURS LATER. THE WARRANTY MAY ALSO COMMENCE IF A WHOLE OR PARTIAL SYSTEM OR ANY SEPARATE PIECE OF EQUIPMENT OR COMPONENT IS PUT INTO USE FOR THE BENEFIT OF ANY PARTY OTHER THAN THE INSTALLING CONTRACTOR WITH PRIOR WRITTEN AUTHORIZATION OF THE OWNER. IN THIS INSTANCE, THE WARRANTY PERIOD SHALL COMMENCE ON THE DATE WHEN SUCH WHOLE SYSTEM, PARTIAL SYSTEM OR SEPARATE PIECE OF EQUIPMENT OR COMPONENT IS PLACED IN OPERATION AND ACCEPTED IN WRITING BY THE OWNER. C.WARRANTY REQUIREMENTS EXTEND TO CORRECTION, WITHOUT COST TO THE OWNER, OF ALL WORK FOUND TO BE DEFECTIVE OR NONCONFORMING TO THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BEAR THE COST OF CORRECTING ALL DAMAGE DUE TO DEFECTS OR NONCONFORMANCE WITH CONTRACT DOCUMENTS EXCLUDING REPAIRS REQUIRED AS A RESULT OF IMPROPER MAINTENANCE OR OPERATION, OR OF NORMAL WEAR AS DETERMINED BY THE ARCHITECT/ENGINEER. 1.10 INSURANCE A.THIS CONTRACTOR SHALL MAINTAIN INSURANCE COVERAGE AS SET FORTH IN DIVISION 1 OF THESE SPECIFICATIONS. 1.11 MATERIAL SUBSTITUTION A.WHERE SEVERAL MANUFACTURERS’NAMES ARE GIVEN, THE MANUFACTURER FOR WHICH A CATALOG NUMBER IS GIVEN IS THE BASIS FOR JOB DESIGN AND ESTABLISHES THE QUALITY. B.EQUIVALENT EQUIPMENT MANUFACTURED BY THE OTHER LISTED MANUFACTURERS MAY BE USED. CONTRACTOR SHALL ENSURE THAT ALL ITEMS SUBMITTED BY THESE OTHER MANUFACTURERS MEET ALL REQUIREMENTS OF THE DRAWINGS AND SPECIFICATIONS AND FITS IN THE ALLOCATED SPACE. WHEN USING OTHER LISTED MANUFACTURERS, THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR ANY AND ALL MODIFICATIONS NECESSARY (INCLUDING, BUT NOT LIMITED TO STRUCTURAL SUPPORTS, ELECTRICAL CONNECTIONS AND ROUGH-IN, AND REGULATORY AGENCY APPROVAL, ETC.) AND COORDINATE SUCH WITH OTHER CONTRACTORS. THE ARCHITECT/ENGINEER SHALL MAKE THE FINAL DETERMINATION OF WHETHER A PRODUCT IS EQUIVALENT. C.ANY MATERIAL, ARTICLE OR EQUIPMENT OF OTHER UNNAMED MANUFACTURERS WHICH WILL ADEQUATELY PERFORM THE SERVICES AND DUTIES IMPOSED BY THE DESIGN AND IS OF A QUALITY EQUAL TO OR BETTER THAN THE MATERIAL, ARTICLE OR EQUIPMENT IDENTIFIED BY THE DRAWINGS AND SPECIFICATIONS MAY BE USED IF APPROVAL IS SECURED IN WRITING FROM THE ARCHITECT/ENGINEER VIA ADDENDUM. THE CONTRACTOR ASSUMES ALL COSTS INCURRED AS A RESULT OF USING THE OFFERED MATERIAL, ARTICLE OR EQUIPMENT, ON THE CONTRACTORS PART OR ON THE PART OF OTHER CONTRACTORS WHOSE WORK IS AFFECTED. D.VOLUNTARY ADD OR DEDUCT PRICES FOR ALTERNATE MATERIALS MAY BE LISTED ON THE BID FORM. THESE ITEMS WILL NOT BE USED IN DETERMINING THE LOW BIDDER. THIS CONTRACTOR ASSUMES ALL COSTS INCURRED AS A RESULT OF USING THE OFFERED MATERIAL OR EQUIPMENT ON THE CONTRACTORS PART OR ON THE PART OF OTHER CONTRACTORS WHOSE WORK IS AFFECTED. E.ALL MATERIAL SUBSTITUTIONS REQUESTED AFTER THE FINAL ADDENDUM MUST BE LISTED AS VOLUNTARY CHANGES ON THE BID FORM. 1.12 PROJECT COMMISSIONING A.THE CONTRACTOR SHALL WORK WITH THE COMMISSIONING AGENT (CXA) AND PROVIDE ALL SERVICES AS DESCRIBED IN THE COMMISSIONING PLAN. PART 2 -PRODUCTS 2.1 GENERAL A.ALL ITEMS OF MATERIAL HAVING A SIMILAR FUNCTION SHALL BE OF THE SAME MANUFACTURER UNLESS SPECIFICALLY STATED OTHERWISE ON DRAWINGS OR ELSEWHERE IN SPECIFICATIONS. PART 3 -EXECUTION 3.1 JOBSITE SAFETY A.NEITHER THE PROFESSIONAL ACTIVITIES OF THE ARCHITECT/ENGINEER, NOR THE PRESENCE OF THE ARCHITECT/ENGINEER OR THE EMPLOYEES AND SUBCONSULTANTS AT A CONSTRUCTION SITE, SHALL RELIEVE THE CONTRACTOR AND ANY OTHER ENTITY OF THEIR OBLIGATIONS, DUTIES AND RESPONSIBILITIES INCLUDING, BUT NOT LIMITED TO, CONSTRUCTION MEANS, METHODS, SEQUENCE, TECHNIQUES OR PROCEDURES NECESSARY FOR PERFORMING, SUPERINTENDING OR COORDINATING ALL PORTIONS OF THE WORK OF CONSTRUCTION IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND ANY HEALTH OR SAFETY PRECAUTIONS REQUIRED BY ANY REGULATORY AGENCIES. THE ARCHITECT/ENGINEER AND PERSONNEL HAVE NO AUTHORITY TO EXERCISE ANY CONTROL OVER ANY CONSTRUCTION CONTRACTOR OR OTHER ENTITY OR THEIR EMPLOYEES IN CONNECTION WITH THEIR WORK OR ANY HEALTH OR SAFETY PRECAUTIONS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR JOBSITE SAFETY. THE ARCHITECT/ENGINEER AND THE ARCHITECT/ENGINEER'S CONSULTANTS SHALL BE INDEMNIFIED AND SHALL BE MADE ADDITIONAL INSUREDS UNDER THE CONTRACTOR'S GENERAL LIABILITY INSURANCE POLICY. 3.2 ARCHITECT/ENGINEER OBSERVATION OF WORK A.THE CONTRACTOR SHALL PROVIDE SEVEN (7) CALENDAR DAYS' NOTICE TO THE ARCHITECT/ENGINEER PRIOR TO: 1.COVERING EXTERIOR WALLS, INTERIOR PARTITIONS AND CHASES. 2.INSTALLING HARD OR SUSPENDED CEILINGS AND SOFFITS. B.THE ARCHITECT/ENGINEER WILL REVIEW THE INSTALLATION AND PROVIDE A WRITTEN REPORT NOTING DEFICIENCIES REQUIRING CORRECTION. THE CONTRACTOR'S SCHEDULE SHALL ACCOUNT FOR THESE REVIEWS AND SHOW THEM AS LINE ITEMS IN THE APPROVED SCHEDULE. C.ABOVE-CEILING FINAL OBSERVATION: 1.ALL WORK ABOVE THE CEILINGS MUST BE COMPLETE PRIOR TO THE ARCHITECT/ENGINEER'S REVIEW. THIS INCLUDES, BUT IS NOT LIMITED TO: a.ALL JUNCTION BOXES ARE CLOSED AND IDENTIFIED IN ACCORDANCE WITH SECTION 26 05 53 ELECTRICAL IDENTIFICATION. b.LUMINAIRES, INCLUDING CEILING-MOUNTED EXIT AND EMERGENCY LIGHTS, ARE INSTALLED AND OPERATIONAL. c.LUMINAIRE WHIPS ARE SUPPORTED ABOVE THE CEILING. d.CONDUIT IDENTIFICATION IS INSTALLED IN ACCORDANCE W ITH SECTION 26 05 53 ELECTRICAL IDENTIFICATION. e.LUMINAIRES ARE SUSPENDED INDEPENDENTLY OF THE CEILING SYSTEM WHEN REQUIRED BY THESE CONTRACT DOCUMENTS. f.ALL WALL PENETRATIONS HAVE BEEN SEALED. 2.TO PREVENT THE ABOVE-CEILING FINAL OBSERVATION FROM OCCURRING TOO EARLY, THE CONTRACTOR SHALL REVIEW THE STATUS OF THE WORK AND CERTIFY, IN WRITING, THAT THE WORK IS READY FOR THE ABOVE-CEILING FINAL OBSERVATION. 3.IT IS UNDERSTOOD THAT IF THE ARCHITECT/ENGINEER FINDS THE CEILINGS HAVE BEEN INSTALLED PRIOR TO THIS REVIEW AND PRIOR TO SEVEN DAYS ELAPSING, THE ARCHITECT/ENGINEER MAY NOT RECOMMEND FURTHER PAYMENTS TO THE CONTRACTOR UNTIL FULL ACCESS HAS BEEN PROVIDED. 3.3 PROJECT CLOSEOUT A.FINAL JOBSITE OBSERVATION: 1.TO PREVENT THE FINAL JOBSITE OBSERVATION FROM OCCURRING TOO EARLY, THE CONTRACTOR SHALL REVIEW THE COMPLETION STATUS OF THE PROJECT AND CERTIFY THAT THE JOB IS READY FOR THE FINAL JOBSITE OBSERVATION. 2.ATTACHED TO THE END OF THIS SECTION IS A TYPICAL LIST OF ITEMS THAT REPRESENT THE DEGREE OF JOB COMPLETENESS EXPECTED PRIOR TO REQUESTING A REVIEW. THE CONTRACTOR SHALL SIGN THE ATTACHED CERTIFICATION AND RETURN IT TO THE ARCHITECT/ENGINEER SO THAT THE FINAL OBSERVATION CAN BE SCHEDULED. 3.IT IS UNDERSTOOD THAT IF THE ARCHITECT/ENGINEER FINDS THE JOB NOT READY FOR THE FINAL OBSERVATION AND ADDITIONAL TRIPS AND OBSERVATIONS ARE REQUIRED TO BRING THE PROJECT TO COMPLETION, THE COST OF THE ADDITIONAL TIME AND EXPENSES INCURRED BY THE ARCHITECT/ENGINEER WILL BE DEDUCTED FROM THE CONTRACTOR'S FINAL PAYMENT. 4.CONTRACTOR SHALL NOTIFY ARCHITECT/ENGINEER 72 HOURS PRIOR TO INSTALLATION OF CEILINGS OR LAY-IN CEILING TILES. B.THE FOLLOWING MUST BE SUBMITTED BEFORE ARCHITECT/ENGINEER RECOMMENDS FINAL PAYMENT: 1.OPERATION AND MAINTENANCE MANUALS WITH COPIES OF APPROVED SHOP DRAWINGS. 2.RECORD DOCUMENTS INCLUDING MARKED-UP DRAWINGS AND SPECIFICATIONS. 3.PROVIDE SPARE PARTS, MAINTENANCE, AND EXTRA MATERIALS IN QUANTITIES SPECIFIED IN INDIVIDUAL SPECIFICATION SECTIONS. 4.INSPECTION AND TESTING REPORT BY THE FIRE ALARM SYSTEM MANUFACTURER. C.CIRCUIT DIRECTORIES: 1.PROVIDE CUSTOM TYPED CIRCUIT DIRECTORY FOR EACH BRANCH CIRCUIT PANELBOARD. PROVIDE UPDATED CUSTOM TYPED CIRCUIT DIRECTORY FOR EACH EXISTING BRANCH CIRCUIT PANELBOARD WITH NEW OR REVISED CIRCUITS PER THE SCOPE OF WORK. LABEL SHALL INCLUDE EQUIPMENT NAME OR FINAL APPROVED ROOM NAME, ROOM NUMBER, AND LOAD TYPE FOR EACH CIRCUIT (EXAMPLES: SUMP SP-1 OR ROOM 101 RECEPT). REVISE DIRECTORY TO REFLECT CIRCUIT CHANGES REQUIRED TO BALANCE PHASE LOADS. PRINTED COPIES OF THE BID DOCUMENT PANEL SCHEDULES ARE NOT ACCEPTABLE AS CIRCUIT DIRECTORIES. 3.4 OPERATION AND MAINTENANCE MANUALS A.GENERAL: 1.PROVIDE AN ELECTRONIC COPY OF THE O&M MANUALS AS DESCRIBED BELOW FOR ARCHITECT/ENGINEER'S REVIEW AND APPROVAL. THE ELECTRONIC COPY SHALL BE CORRECTED AS REQUIRED TO ADDRESS THE ARCHITECT/ENGINEER'S COMMENTS. ONCE CORRECTED, ELECTRONIC COPIES AND PAPER COPIES SHALL BE DISTRIBUTED AS DIRECTED BY THE ARCHITECT/ENGINEER. 2.APPROVED O&M MANUALS SHALL BE COMPLETED AND IN THE OWNER'S POSSESSION PRIOR TO OWNER'S ACCEPTANCE AND AT LEAST 10 DAYS PRIOR TO INSTRUCTION OF OPERATING PERSONNEL. 3.5 RECORD DOCUMENTS A.THE FOLLOWING PARAGRAPHS SUPPLEMENT DIVISION 1 REQUIREMENTS. B.MAINTAIN AT THE JOB SITE A SEPARATE AND COMPLETE SET OF ELECTRICAL DRAWINGS AND SPECIFICATIONS WITH ALL CHANGES MADE TO THE SYSTEMS CLEARLY AND PERMANENTLY MARKED IN COMPLETE DETAIL. B.ALL ELECTRICAL CONDUIT AND EQUIPMENT, FITTINGS, HANGERS, STRUCTURAL SUPPORTS, ETC., IN UNFINISHED AREAS, SUCH AS EQUIPMENT AND STORAGE ROOM AREA, SHALL BE PAINTED TWO (2) COATS OF OIL PAINT OF COLORS SELECTED BY THE ARCHITECT. C.DO NOT PAINT ELECTRIC CONDUITS IN CRAWL SPACES, TUNNELS, OR SPACES ABOVE SUSPENDED CEILINGS EXCEPT THAT WHERE CONDUIT IS IN A DAMP LOCATION GIVE EXPOSED THREADS AT JOINTS TWO COATS OF SEALER AFTER JOINT IS MADE UP. 3.7 ADJUST AND CLEAN A.THOROUGHLY CLEAN ALL EQUIPMENT AND SYSTEMS PRIOR TO THE OWNER'S FINAL ACCEPTANCE OF THE PROJECT. B.CLEAN ALL FOREIGN PAINT, GREASE, OIL, DIRT, LABELS, STICKERS, ETC. FROM ALL EQUIPMENT. C.REMOVE ALL RUBBISH, DEBRIS, ETC., ACCUMULATED DURING CONSTRUCTION FROM THE PREMISES. 3.8 SPECIAL REQUIREMENTS A.ADHESIVES AND SEALANTS: ALL SEALERS, ADHESIVES, AND SEALANTS SHALL COMPLY WITH THE LOW EMITTING MATERIAL LIMITS OF THE FOLLOW ING STANDARDS: 1.CDPH STANDARD METHOD V1.1-2010 -STANDARD METHOD FOR THE TESTING AND EVALUATION OF VOLATILE ORGANIC CHEMICAL EMISSIONS VOC FROM INDOOR SOURCES USING ENVIRONMENTAL CHAMBERS VERSION 1.1. 2.SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168 -ADHESIVE AND SEALANT APPLICATIONS. ALL ADHESIVES AND SEALANTS WET-APPLIED ON SITE SHALL COMPLY WITH THE APPLICABLE CHEMICAL CONTENT REQUIREMENTS OF SCAQMD RULE 1168. 3.SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE SCAQMD 1113 -WET APPLIED PAINTS AND COATINGS. ALL PAINTS AND COATINGS WET-APPLIED ON SITE MUST MEET THE APPLICABLE VOC LIMITS OF SCAQMD RULE 1113. 3.9 FIELD QUALITY CONTROL A.GENERAL: 1.CONDUCT ALL TESTS REQUIRED DURING AND AFTER CONSTRUCTION. SUBMIT TEST RESULTS IN NETA FORMAT, OR EQUIVALENT FORM, THAT SHOWS THE TEST EQUIPMENT USED, CALIBRATION DATE, TESTER'S NAME, AMBIENT TEST CONDITIONS, HUMIDITY, CONDUCTOR LENGTH, AND RESULTS CORRECTED TO 40°C. 2.SUPPLY NECESSARY INSTRUMENTS, METERS, ETC., FOR THE TESTS. SUPPLY COMPETENT TECHNICIANS WITH TRAINING IN THE PROPER TESTING TECHNIQUES. 3.ALL CABLES AND WIRES SHALL BE TESTED FOR SHORTS AND GROUNDS FOLLOWING INSTALLATION AND CONNECTION TO DEVICES. REPLACE SHORTED OR GROUNDED WIRES AND CABLES. 4.ANY WIRING DEVICE, ELECTRICAL APPARATUS OR LUMINAIRE, IF GROUNDED OR SHORTED ON ANY INTEGRAL "LIVE" PART, SHALL HAVE ALL DEFECTIVE PARTS OR MATERIALS REPLACED. 5.TEST CABLE INSULATION OF SERVICE AND PANEL FEEDER CONDUCTORS FOR PROPER INSULATION VALUES. TESTS SHALL INCLUDE THE CABLE, ALL SPLICES, AND ALL TERMINATIONS. EACH CONDUCTOR SHALL BE TESTED AND SHALL TEST FREE OF SHORT CIRCUITS AND GROUNDS AND HAVE AN INSULATION VALUE NOT LESS THAN ELECTRICAL CODE STANDARDS. TAKE READINGS BETWEEN CONDUCTORS, AND BETWEEN CONDUCTORS AND GROUND. 6.IF THE RESULTS OBTAINED IN THE TESTS ARE NOT SATISFACTORY, MAKE ADJUSTMENTS, REPLACEMENTS, AND CHANGES AS NEEDED. THEN REPEAT THE TESTS, AND MAKE ADDITIONAL TESTS, AS THE ARCHITECT/ENGINEER OR AUTHORITY HAVING JURISDICTION DEEMS NECESSARY. B.IF ANY TEST RESULTS ARE NOT SATISFACTORY, MAKE ADJUSTMENTS, REPLACEMENTS AND CHANGES AS NEEDED AND REPEAT THE TESTS AND MAKE ADDITIONAL TESTS AS THE ARCHITECT/ENGINEER OR AUTHORITY HAVING JURISDICTION DEEM NECESSARY. C.CONTRACTOR SHALL THERMOGRAPHIC STUDY ALL PANELBOARDS AT THE END OF CONSTRUCTION TO IDENTIFY ANY UNUSUAL CONDITIONS/HEATING WITHIN THE EQUIPMENT. COORDINATE WITH OWNER/ARCHITECT/ENGINEER TO HAVE AN OWNER/ARCHITECT/ENGINEER REPRESENTATIVE PRESENT DURING TESTING. READINESS CERTIFICATION PRIOR TO FINAL JOBSITE OBSERVATION TO PREVENT THE FINAL JOB OBSERVATION FROM OCCURRING TOO EARLY, WE REQUIRE THAT THE CONTRACTOR REVIEW THE COMPLETION STATUS OF THE PROJECT AND, BY COPY OF THIS DOCUMENT, CERTIFY THAT THE JOB IS INDEED READY FOR THE FINAL JOB OBSERVATION. THE FOLLOWING IS A TYPICAL LIST OF ITEMS THAT REPRESENT THE DEGREE OF JOB COMPLETENESS EXPECTED PRIOR TO YOUR REQUESTING A FINAL JOB OBSERVATION. 1. PENETRATIONS OF FIRE-RATED CONSTRUCTION FIRE SEALED IN ACCORDANCE WITH SPECIFICATIONS. 2. ELECTRICAL PANELS HAVE TYPED CIRCUIT IDENTIFICATION. 3. PER SECTION 26 05 00, CABLE INSULATION TEST RESULTS HAVE BEEN SUBMITTED. ACCEPTED BY: PRIME CONTRACTOR _______________________________________________ BY ___________________________________ DATE ___________________ UPON CONTRACTOR CERTIFICATION THAT THE PROJECT IS COMPLETE AND READY FOR A FINAL JOB OBSERVATION, WE REQUIRE THE CONTRACTOR TO SIGN THIS AGREEMENT AND RETURN IT TO THE ARCHITECT/ENGINEER SO THAT THE FINAL OBSERVATION CAN BE SCHEDULED. END OF SECTION ELECTRICAL SPECIFICATIONS TABLE OF CONTENT • SECTION 26 05 00 -BASIC ELECTRICAL REQUIREMENTS • SECTION 26 05 05 -ELECTRICAL DEMOLITION FOR REMODELING C.MARK DRAWINGS AND SPECIFICATIONS TO INDICATE APPROVED SUBSTITUTIONS; CHANGE ORDERS, AND ACTUAL EQUIPMENT AND MATERIALS USED. ALL CHANGE ORDERS, RFI RESPONSES, CLARIFICATIONS AND OTHER SUPPLEMENTAL INSTRUCTIONS SHALL BE MARKED ON THE DOCUMENTS. RECORD DOCUMENTS THAT MERELY REFERENCE THE EXISTENCE OF THE ABOVE ITEMS ARE NOT ACCEPTABLE. SHOULD THIS CONTRACTOR FAIL TO COMPLETE RECORD DOCUMENTS AS REQUIRED BY THIS CONTRACT, THIS CONTRACTOR SHALL REIMBURSE ARCHITECT/ENGINEER FOR ALL COSTS TO DEVELOP RECORD DOCUMENTS THAT COMPLY WITH THIS REQUIREMENT. REIMBURSEMENT SHALL BE MADE AT THE ARCHITECT/ENGINEER'S HOURLY RATES IN EFFECT AT THE TIME OF WORK. D.RECORD CHANGES DAILY AND KEEP THE MARKED DRAWINGS AVAILABLE FOR THE ARCHITECT/ENGINEER'S EXAMINATION AT ANY NORMAL WORK TIME. E.UPON COMPLETING THE JOB, AND BEFORE FINAL PAYMENT IS MADE, GIVE THE MARKED- UP DRAWINGS TO THE ARCHITECT/ENGINEER. 3.6 PAINTING A.PAINT ALL EQUIPMENT THAT IS MARRED OR DAMAGED PRIOR TO THE OWNER'S ACCEPTANCE. PAINT AND COLOR SHALL MATCH ORIGINAL EQUIPMENT PAINT AND SHALL BE OBTAINED FROM THE EQUIPMENT SUPPLIER IF AVAILABLE. ALL EQUIPMENT SHALL HAVE A FINISHED COAT OF PAINT APPLIED UNLESS SPECIFICALLY ALLOWED TO BE PROVIDED WITH A PRIME COAT ONLY. SECTION 26 05 05 -ELECTRICAL DEMOLITION FOR REMODELING PART 1 -GENERAL 1.1 SECTION INCLUDES A.ELECTRICAL DEMOLITION PART 2 -PRODUCTS 2.1 MATERIALS AND EQUIPMENT A.MATERIALS AND EQUIPMENT FOR PATCHING AND EXTENDING WORK SHALL BE AS SPECIFIED IN INDIVIDUAL SECTIONS. PART 3 -EXECUTION 3.1 EXAMINATION A.THE DRAWINGS ARE INTENDED TO INDICATE THE SCOPE OF WORK REQUIRED AND DO NOT INDICATE EVERY BOX, CONDUIT, OR WIRE THAT MUST BE REMOVED. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTING A BID AND VERIFY EXISTING CONDITIONS. B.WHERE WALLS, CEILINGS, STRUCTURES, ETC., ARE INDICATED AS BEING REMOVED ON GENERAL OR ELECTRICAL DRAWINGS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL ELECTRICAL EQUIPMENT, DEVICES, FIXTURES, RACEWAYS, WIRING, SYSTEMS, ETC., FROM THE REMOVED AREA. C.COORDINATE SCOPE OF WORK WITH ALL OTHER CONTRACTORS AND THE OWNER AT THE PROJECT SITE. SCHEDULE REMOVAL OF EQUIPMENT AND ELECTRICAL SERVICE TO AVOID CONFLICTS. D.BID SUBMITTAL SHALL MEAN THE CONTRACTOR HAS VISITED THE PROJECT SITE AND HAS VERIFIED EXISTING CONDITIONS AND SCOPE OF WORK. 3.2 PREPARATION A.THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE OWNER BEFORE TURNING OFF POWER TO CIRCUITS, FEEDERS, PANELS, ETC. COORDINATE ALL OUTAGES WITH OWNER. B.PROVIDE TEMPORARY WIRING AND CONNECTIONS TO MAINTAIN EXISTING SYSTEMS IN SERVICE DURING CONSTRUCTION. WHEN WORK MUST BE PERFORMED ON ENERGIZED EQUIPMENT OR CIRCUITS, USE PERSONNEL EXPERIENCED IN SUCH OPERATIONS. ASSUME ALL EQUIPMENT AND SYSTEMS MUST REMAIN OPERATIONAL UNLESS SPECIFICALLY NOTED OTHERWISE ON DRAWINGS. C.DISCONNECT ELECTRICAL SYSTEMS IN WALLS, FLOORS, STRUCTURES, AND CEILINGS SCHEDULED FOR REMOVAL. 3.3 DEMOLITION AND EXTENSION OF EXISTING ELECTRICAL WORK A.DEMOLISH AND EXTEND EXISTING ELECTRICAL WORK UNDER PROVISIONS OF DIVISION 1 OF SPECIFICATIONS AND THIS SECTION. B.REMOVE, RELOCATE, AND EXTEND EXISTING INSTALLATIONS TO ACCOMMODATE NEW CONSTRUCTION. C.REMOVE EXPOSED ABANDONED RACEWAY, INCLUDING ABANDONED RACEWAY ABOVE ACCESSIBLE CEILING FINISHES. CUT RACEWAY FLUSH WITH WALLS AND FLOORS, AND PATCH SURFACES. REMOVE ALL ASSOCIATED CLAMPS, HANGERS, SUPPORTS, ETC. ASSOCIATED WITH RACEWAY REMOVAL. D.DISCONNECT AND REMOVE OUTLETS AND DEVICES THAT ARE TO BE DEMOLISHED. REMOVE OUTLET OR DEVICES' ASSOCIATED BACK BOX, SUPPORTS, AND CONDUIT AND CONDUCTORS BACK TO SOURCE. PATCH OPENING CREATED FROM REMOVAL OF DEVICE TO MATCH SURROUNDING FINISHES. E.REPAIR ADJACENT CONSTRUCTION AND FINISHES DAMAGED DURING DEMOLITION AND EXTENSION WORK. PATCH OPENINGS TO MATCH EXISTING SURROUNDING FINISHES. F.MAINTAIN ACCESS TO EXISTING ELECTRICAL INSTALLATIONS THAT REMAIN ACTIVE. MODIFY INSTALLATION OR PROVIDE JUNCTION BOXES AND ACCESS PANEL AS APPROPRIATE. G.EXTEND EXISTING INSTALLATIONS USING MATERIALS AND METHODS COMPATIBLE WITH EXISTING ELECTRICAL INSTALLATIONS, OR AS SPECIFIED. EXTENDED CONDUIT AND CONDUCTORS TO MATCH EXISTING SIZE AND MATERIAL. H.THIS CONTRACTOR IS RESPONSIBLE FOR ALL COSTS INCURRED IN REPAIR, RELOCATIONS, OR REPLACEMENT OF ANY CABLES, CONDUITS, OR OTHER SERVICES IF DAMAGED WITHOUT PROPER INVESTIGATION. 3.4 CLEANING AND REPAIR A.CLEAN AND REPAIR EXISTING MATERIALS AND EQUIPMENT THAT REMAIN OR ARE TO BE REUSED. B.PANELBOARDS: CLEAN EXPOSED SURFACES AND CHECK TIGHTNESS OF ELECTRICAL CONNECTIONS. REPLACE DAMAGED CIRCUIT BREAKERS AND PROVIDE CLOSURE PLATES FOR VACANT POSITIONS. PROVIDE TYPED CIRCUIT DIRECTORY SHOWING REVISED CIRCUITING ARRANGEMENT. C.ELECTRICAL ITEMS (E.G., LIGHTING FIXTURES, RECEPTACLES, SWITCHES, CONDUIT, WIRE, ETC.) REMOVED AND NOT RELOCATED REMAIN THE PROPERTY OF THE OWNER. CONTRACTOR SHALL PLACE ITEMS RETAINED BY THE OWNER IN A LOCATION COORDINATED WITH THE OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DISPOSAL OF MATERIAL THE OWNER DOES NOT WANT. 3.5 INSTALLATION A.INSTALL RELOCATED MATERIALS AND EQUIPMENT UNDER THE PROVISIONS OF DIVISION 1 OF SPECIFICATIONS. END OF SECTION No. Revisions Date pl a n c h e c k s u b m i t t a l TE OLIRFFOAC LANRP E 23191 STA ER REGIST ED INA N REENIGE FO OISSE E AICLCERTL Exp. 06/30/26 MIRASOPHOCLISGEORGY IMEG RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAW ING AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG AND SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG. ©2024 IMEG CONSULTANTS CORP. REF. SCALE IN INCHES 0 1 2 3 222 S. HARBOR BOULEVARD SUITE 800 ANAHEIM, CA 92805 P: 714.490.5555 F: 714.490.5560 The FUTURE. Built Smarter www.imegcorp.com PROJECT #24007312.00 0 5' GRAPHIC SCALES: Issue Date 1/16" = 1'-0" 50' 1/8" = 1'-0"1/4" = 1'-0"1/2" = 1'-0"3/4" = 1'-0"1" = 1'-0"1-1/2" = 1'-0"3" = 1'-0" 0 5'25' 0 1'12' 0 1'6' 0 4' 0 3'1'0 2' 0 1' Chckd By Drwn By Scale Building ID: KP Proj. No. Permit No. Sheet SheetsOf Sheet Title Project Facility This document is the property of the Owner and is Project Architect Approval: Architect/Engineer Of Record: IF THIS SHEET IS NOT 30"x42" , IT IS A REDUCED PRINT - SCALE ACCORDINGLY National Facilities Services Post Office Box 12916 Oakland California 94604 not to be used without owner's written permission. Floor Lev: Section: HGW Proj. No. © A R C H I T E C T S h a n n a g a b r i e l w e l l s , a l l r i g h t s r e s e r v ed . A n y u s e w i t h o u t p e r m i s s i o n i s e x p r e s s l y p r o h i b i t ed . P l o t t e d CAP029271 1955 Bacon Street. San Diego, CA 92107 Office 619 523 8487 www.hgwarchitecture.com PROJECT #24007312.00 Revisions By Appr. KAISER HARBOR MACARTHUR MOB EXTERIOR SIGNAGE KAISER PERMANENTE HARBOR MACARTHUR MOB 1/ 2 3 / 2 0 2 6 1 2 : 4 5 : 5 3 P M 01/23/2026 MG CL ES003 ELECTRICAL SPECIFICATIONS 3401 South Harbor Boulevard, Santa Ana, CA 92704 10 0 % C D S E T 2441 SECTION 26 05 13 -WIRE AND CABLE PART 1 -GENERAL 1.1 SECTION INCLUDES A.BUILDING WIRE B.CABLING FOR REMOTE CONTROL, SIGNAL, AND POWER LIMITED CIRCUITS 1.2 RELATED WORK A.SECTION 26 05 53 -ELECTRICAL IDENTIFICATION: REFER TO ELECTRICAL IDENTIFICATION FOR COLOR AND IDENTIFICATION LABELING REQUIREMENTS. 1.3 REFERENCES A.NEMA WC 70 -POWER CABLES RATED 2,000V OR LESS FOR THE DISTRIBUTION OF ELECTRICAL ENERGY B.CEC CALIFORNIA ELECTRICAL CODE C.UL 83 -THERMOPLASTIC-INSULATED WIRES AND CABLES D.UL 1581 -STANDARD FOR ELECTRICAL WIRES, CABLES, AND FLEXIBLE CORDS 1.4 SUBMITTALS A.SUBMIT SHOP DRAWINGS AND PRODUCT DATA UNDER THE PROVISIONS OF SECTION 26 05 00. PART 2 -PRODUCTS 2.1 BUILDING WIRE A.FEEDERS AND BRANCH CIRCUITS 8 AWG AND LARGER: COPPER, STRANDED CONDUCTOR, 600-VOLT INSULATION, THHN/THWN OR XHHW-2. B.FEEDERS AND BRANCH CIRCUITS 10 AWG AND SMALLER: COPPER, SOLID OR STRANDED CONDUCTOR, 600-VOLT INSULATION, THHN/THWN, UNLESS OTHERWISE NOTED ON THE DRAWINGS. C.CONTROL CIRCUITS: COPPER, STRANDED CONDUCTOR 600-VOLT INSULATION, THHN/THWN. D.EACH 120 AND 277-VOLT BRANCH CIRCUIT SHALL HAVE A DEDICATED NEUTRAL CONDUCTOR. NEUTRAL CONDUCTORS SHALL BE CONSIDERED CURRENT-CARRYING CONDUCTORS FOR WIRE DERATING. 2.2 CABLING FOR REMOTE CONTROL, SIGNAL, AND POWER LIMITED CIRCUITS A.WIRE FOR THE FOLLOWING SPECIALIZED SYSTEMS SHALL BE AS DESIGNATED ON THE DRAWINGS, OR ELSEWHERE IN THESE SPECIFICATIONS. IF NOT DESIGNATED ON THE DRAWINGS OR SPECIFICATIONS, THE SYSTEM MANUFACTURER'S RECOMMENDATIONS SHALL BE FOLLOWED. 1.LOW VOLTAGE SWITCHING AND LIGHTING CONTROL B.CONTROL CABLE FOR CLASS 1 REMOTE CONTROL AND SIGNAL CIRCUITS: COPPER CONDUCTOR, 600-VOLT INSULATION, RATED 60°C, INDIVIDUAL CONDUCTORS TWISTED TOGETHER, SHIELDED, AND COVERED WITH A PVC JACKET. C.CONTROL CABLE FOR CLASS 2 OR CLASS 3 REMOTE CONTROL AND SIGNAL CIRCUITS: COPPER CONDUCTOR, 300-VOLT INSULATION, RATED 60°C, INDIVIDUAL CONDUCTORS TWISTED TOGETHER, SHIELDED, AND COVERED WITH A PVC JACKET; UL LISTED. D.PLENUM CABLE FOR CLASS 2 OR CLASS 3 REMOTE CONTROL AND SIGNAL CIRCUITS: COPPER CONDUCTOR, 300-VOLT INSULATION, RATED 60°C, INDIVIDUAL CONDUCTORS TWISTED TOGETHER, SHIELDED, AND COVERED WITH A NONMETALLIC JACKET; UL LISTED FOR USE IN AIR HANDLING DUCTS, HOLLOW SPACES USED AS DUCTS, AND PLENUMS. PART 3 -EXECUTION 3.1 WIRE AND CABLE INSTALLATION SCHEDULE A.ABOVE ACCESSIBLE CEILINGS: 1.BUILDING WIRE SHALL BE INSTALLED IN RACEWAY. B.ALL OTHER LOCATIONS: BUILDING WIRE IN RACEWAY. C.LOW VOLTAGE CABLE (LESS THAN 100 VOLTS): LOW VOLTAGE CABLES IN DUCTS, PLENUMS, AND OTHER AIR HANDLING SPACES SHALL BE PLENUM LISTED. LOW VOLTAGE CABLES IN NON-ACCESSIBLE AREAS SHALL BE INSTALLED IN CONDUIT. D.LOW VOLTAGE CABLE (LESS THAN 100 VOLTS): LOW VOLTAGE CABLE SHALL BE INSTALLED IN RACEWAY. 3.2 CONTRACTOR CHANGES A.THE BASIS OF DESIGN IS COPPER CONDUCTORS INSTALLED IN RACEWAY BASED ON AMBIENT TEMPERATURE OF 30°C, CEC CALIFORNIA ELECTRICAL CODE EDITION TABLE 310.15(B)(16). B.THE CONTRACTOR SHALL BE RESPONSIBLE FOR DERATING AND SIZING CONDUCTORS AND CONDUITS TO EQUAL OR EXCEED THE AMPACITY OF THE BASIS OF DESIGN CIRCUITS, IF HE/SHE CHOOSES TO USE METHODS OR MATERIALS OTHER THAN THE BASIS OF DESIGN. C.THE DRAWINGS ARE DIAGRAMMATIC WITH INTENT TO CONVEY THE COMPONENTS OF THE ELECTRICAL DISTRIBUTION SYSTEM. CONDUCTOR LENGTH(S) WHEN LISTED ON PLANS AND SCHEDULES ARE FOR ENGINEERING CALCULATION PURPOSES. CONDUCTOR LENGTH(S) SHALL NOT BE USED FOR BIDDING PURPOSES. D.RECORD DRAWING SHALL INCLUDE THE CALCULATIONS AND SKETCHES. 3.3 GENERAL WIRING METHODS A.USE NO WIRE SMALLER THAN 12 AWG FOR POWER AND LIGHTING CIRCUITS, AND NO SMALLER THAN 14 AWG FOR CONTROL WIRING. B.USE NO WIRE SMALLER THAN 18 AWG FOR LOW VOLTAGE CONTROL WIRING BELOW 100 VOLTS. C.USE 10 AWG CONDUCTOR FOR 20 AMPERE, 120-VOLT BRANCH CIRCUIT HOME RUNS LONGER THAN 75 FEET, AND FOR 20 AMPERE, 277-VOLT BRANCH CIRCUIT HOME RUNS LONGER THAN 200 FEET. D.THE AMPACITY OF MULTIPLE CONDUCTORS IN ONE CONDUIT SHALL BE DERATED PER THE ELECTRICAL CODE. E.SPLICE ONLY IN JUNCTION OR OUTLET BOXES. F.NEATLY TRAIN AND LACE WIRING INSIDE BOXES, EQUIPMENT, AND PANELBOARDS. G.MAKE CONDUCTOR LENGTHS FOR PARALLEL CIRCUITS EQUAL. H.ALL CONDUCTORS SHALL BE CONTINUOUS IN CONDUIT FROM LAST OUTLET TO THEIR TERMINATION. I.TERMINATE ALL SPARE CONDUCTORS ON TERMINAL BLOCKS, AND LABEL THE SPARE CONDUCTORS. J.CABLES OR WIRES SHALL NOT BE LAID OUT ON THE GROUND BEFORE PULLING. K.CABLES OR WIRES SHALL NOT BE DRAGGED OVER EARTH OR PAVING. L.CARE SHALL BE TAKEN SO AS NOT TO SUBJECT THE CABLE OR WIRE TO HIGH MECHANICAL STRESSES THAT WOULD CAUSE DAMAGE TO THE WIRE AND CABLE. M.ALL WIRES IN OUTLET BOXES NOT CONNECTED TO FIXTURES OR OTHER DEVICES SHALL BE ROLLED UP, SPLICED IF CONTINUITY OF CIRCUIT IS REQUIRED, AND INSULATED. 3.4 WIRING INSTALLATION IN RACEWAYS A.PULL ALL CONDUCTORS INTO A RACEWAY AT THE SAME TIME. USE UL LISTED WIRE PULLING LUBRICANT FOR PULLING 4 AWG AND LARGER WIRES. B.PULLING SHALL BE CONTINUOUS WITHOUT UNNECESSARY STOPS AND STARTS WITH WIRE OR CABLE ONLY PARTIALLY THROUGH RACEWAY. C.WHERE REELS OF CABLE OR WIRE ARE USED, THEY SHALL BE SET UP ON JACKS CLOSE TO THE POINT WHERE THE WIRE OR CABLE ENTERS THE CONDUIT OR DUCT SO THAT THE CABLE OR WIRE MAY BE UNREELED AND RUN INTO THE CONDUIT OR DUCT WITH A MINIMUM OF CHANGE IN THE DIRECTION OF THE BEND. D.CONDUCTORS SHALL NOT BE PULLED THROUGH CONDUITS UNTIL PLASTERING OR MASONRY WORK IS COMPLETED AND CONDUITS ARE FREE FROM MOISTURE. CARE SHALL BE TAKEN SO THAT LONG PULLS OF WIRE OR PULLS AROUND SEVERAL BENDS ARE NOT MADE WHERE THE WIRE MAY BE PERMANENTLY STRETCHED AND THE INSULATION DAMAGED. E.ONLY NYLON ROPE SHALL BE PERMITTED TO PULL CABLES INTO CONDUIT AND DUCTS. F.COMPLETELY AND THOROUGHLY SWAB RACEWAY SYSTEM BEFORE INSTALLING CONDUCTORS. G.CONDUCTOR SUPPORTS IN VERTICAL RACEWAYS: 1.SUPPORT CONDUCTORS IN VERTICAL RACEWAYS IN ACCORDANCE WITH THE ELECTRICAL CODE SPACING OF CONDUCTORS SUPPORTS. 2.SUPPORTS SHALL BE OF INSULATED WEDGE TYPE (OZ GEDNEY TYPE S, OR EQUAL) AND INSTALLED IN A TAPERED INSULATED BUSHING FITTING OR A METAL WOVEN MESH WITH A SUPPORT RING THAT FITS INSIDE CONDUIT FITTING INSTALLED IN AN ACCESSIBLE JUNCTION BOX (HUBBELL KELLEMS SUPPORT GRIP OR EQUAL). 3.5 CABLE INSTALLATION A.PROVIDE PROTECTION FOR EXPOSED CABLES WHERE SUBJECT TO DAMAGE. B.USE SUITABLE CABLE FITTINGS AND CONNECTORS. C.RUN ALL OPEN CABLE PARALLEL OR PERPENDICULAR TO WALLS, CEILINGS, AND EXPOSED STRUCTURAL MEMBERS. FOLLOW THE ROUTING AS ILLUSTRATED ON THE DRAWINGS AS CLOSELY AS POSSIBLE. CABLE ROUTING ON DRAWINGS SCALED 1/4"=1'-0" OR LESS SHALL BE CONSIDERED DIAGRAMMATICAL, UNLESS NOTED OTHERWISE. THE CORRECT ROUTING, WHEN SHOWN DIAGRAMMATICALLY, SHALL BE CHOSEN BY THE CONTRACTOR BASED ON INFORMATION IN THE CONTRACT DOCUMENTS; IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS, APPLICABLE CODES, THE NECA'S "STANDARD OF INSTALLATION", RECOGNIZED INDUSTRY STANDARDS; AND COORDINATED WITH OTHER CONTRACTORS. D.OPEN CABLE SHALL BE SUPPORTED BY THE APPROPRIATE SIZE J-HOOKS OR OTHER MEANS IF CALLED FOR ON THE DRAWINGS. WIRE AND CABLE FROM DIFFERENT SYSTEMS SHALL NOT BE INSTALLED IN THE SAME J-HOOK. J-HOOKS SHALL BE SIZED WITH 20% SPARE CAPACITY. J-HOOKS SHALL PROVIDE PROPER BEND RADIUS SUPPORT FOR DATA CABLE AND FIBER CABLES. E.OPEN CABLE INSTALLED ABOVE SUSPENDED CEILINGS SHALL NOT REST ON THE SUSPENDED CEILING CONSTRUCTION, NOR UTILIZE THE CEILING SUPPORT SYSTEM FOR WIRE AND CABLE SUPPORT. F.OPEN CABLE SHALL ONLY BE INSTALLED WHERE SPECIFICALLY SHOWN ON THE DRAWINGS, OR PERMITTED IN THESE SPECIFICATIONS. 3.6 WIRING CONNECTIONS AND TERMINATIONS A.SPLICE AND TAP ONLY IN ACCESSIBLE JUNCTION BOXES. B.USE SOLDERLESS, TIN-PLATED COPPER, COMPRESSION TERMINALS (LUGS) APPLIED WITH CIRCUMFERENTIAL CRIMP FOR CONDUCTOR TERMINATIONS, 8 AWG AND LARGER. C.USE SOLDERLESS, TIN-PLATED, COMPRESSION TERMINALS (LUGS) APPLIED WITH INDENTER CRIMP FOR COPPER CONDUCTOR TERMINATIONS, 10 AWG AND SMALLER. D.USE SOLDERLESS PRESSURE CONNECTORS WITH INSULATING COVERS FOR COPPER WIRE SPLICES AND TAPS, 8 AWG AND SMALLER. FOR 10 AW G AND SMALLER, USE INSULATED SPRING WIRE CONNECTORS WITH PLASTIC CAPS. E.USE COMPRESSION CONNECTORS APPLIED WITH CIRCUMFERENTIAL CRIMP FOR CONDUCTOR SPLICES AND TAPS, 6 AWG AND LARGER. TAPE UNINSULATED CONDUCTORS AND CONNECTORS WITH ELECTRICAL TAPE TO 150 PERCENT OF THE INSULATION VALUE OF CONDUCTOR. F.THOROUGHLY CLEAN WIRES BEFORE INSTALLING LUGS AND CONNECTORS. G.MAKE SPLICES, TAPS AND TERMINATIONS TO CARRY FULL AMPACITY OF CONDUCTORS WITHOUT PERCEPTIBLE TEMPERATURE RISE. H.PHASE SEQUENCE: ALL APPARATUS SHALL BE CONNECTED TO OPERATE IN THE PHASE SEQUENCE A-B-C REPRESENTING THE TIME SEQUENCE IN WHICH THE PHASE CONDUCTORS SO IDENTIFIED REACH POSITIVE MAXIMUM VOLTAGE. I.AS A GENERAL RULE, APPLICABLE TO SWITCHES, CIRCUIT BREAKERS, STARTERS, PANELBOARDS, SWITCHGEAR AND THE LIKE, THE CONNECTIONS TO PHASE CONDUCTORS ARE INTENDED THUS: 1.FACING THE FRONT AND OPERATING SIDE OF THE EQUIPMENT, THE PHASE IDENTIFICATION SHALL BE: a.LEFT TO RIGHT -A-B-C b.TOP TO BOTTOM -A-B-C 3.7 FIELD QUALITY CONTROL A.FIELD INSPECTION AND TESTING WILL BE PERFORMED UNDER PROVISIONS OF DIVISION 1. B.BUILDING WIRE AND POWER CABLE TESTING: PERFORM AN INSULATION-RESISTANCE TEST ON EACH CONDUCTOR WITH RESPECT TO GROUND AND ADJACENT CONDUCTORS. TEST SHALL BE MADE BY MEANS OF A LOW -RESISTANCE OHMMETER, SUCH AS A "MEGGER". THE APPLIED POTENTIAL SHALL BE 500 VOLTS DC FOR 300 VOLT RATED CABLE AND 1000 VOLTS DC FOR 600 VOLT RATED CABLE. THE TEST DURATION SHALL BE ONE MINUTE. INSULATION RESISTANCE MUST BE GREATER THAN 100 MEGA-OHM FOR 600 VOLT AND 25 MEGA-OHM FOR 300 VOLT RATED CABLES PER NETA ACCEPTANCE TESTING STANDARD. VERIFY UNIFORM RESISTANCE OF PARALLEL CONDUCTORS. C.INSPECT WIRE AND CABLE FOR PHYSICAL DAMAGE AND PROPER CONNECTION. D.TORQUE TEST CONDUCTOR CONNECTIONS AND TERMINATIONS TO MANUFACTURER'S RECOMMENDED VALUES. E.PERFORM CONTINUITY TEST ON ALL POWER AND EQUIPMENT BRANCH CIRCUIT CONDUCTORS. VERIFY PROPER PHASING CONNECTIONS. F.PROVIDE DOCUMENTATION OF THE MANUFACTURER'S RECOMMENDED LUG TORQUE VALUE FOR COPPER AND ALUMINUM CONDUCTORS, THE DATE THE LUGS WERE TORQUED, AND INSTALLED TORQUE READINGS. DOCUMENTATION INDICATING THAT THE TORQUE WRENCH HAS BEEN CALIBRATED NOT MORE THAN 30 DAYS PRIOR TO TIGHTENING OF LUGS SHALL BE PROVIDED. G.PROTECTION OF WIRE AND CABLE FROM FOREIGN MATERIALS: 1.IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE PHYSICAL PROTECTION TO PREVENT FOREIGN MATERIAL APPLICATION OR CONTACT WITH ANY WIRE OR CABLE TYPE. FOREIGN MATERIAL IS DEFINED AS ANY MATERIAL THAT WOULD NEGATIVELY IMPACT THE VALIDITY OF THE MANUFACTURER'S PERFORMANCE WARRANTY. THIS INCLUDES, BUT IS NOT LIMITED TO, OVERSPRAY OF PAINT (ACCIDENTAL OR OTHERWISE), DRYWALL COMPOUND, OR ANY OTHER SURFACE CHEMICAL, LIQUID, OR COMPOUND THAT COULD COME IN CONTACT WITH THE CABLE, CABLE JACKET, OR CABLE TERMINATION COMPONENTS. H.OVERSPRAY OF PAINT ON ANY WIRE OR CABLE WILL NOT BE ACCEPTED. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO REPLACE ANY COMPONENT CONTAINING OVERSPRAY, IN ITS ENTIRETY, AT NO ADDITIONAL COST TO THE PROJECT. CLEANING OF THE CABLES WITH HARSH CHEMICALS IS NOT ALLOWED. END OF SECTION ELECTRICAL SPECIFICATIONS TABLE OF CONTENT • SECTION 26 05 13 -WIRE AND CABLE • SECTION 26 05 33 -CONDUIT AND BOXES SECTION 26 05 33 -CONDUIT AND BOXES PART 1 -GENERAL 1.1 SECTION INCLUDES A.ELECTRICAL METALLIC TUBING AND FITTINGS (EMT) B.FLEXIBLE METALLIC CONDUIT AND FITTINGS (FMC) C.WALL AND CEILING OUTLET BOXES D.PULL AND JUNCTION BOXES E.ROUGH-INS 1.2 RELATED WORK A.SECTION 26 05 53 -ELECTRICAL IDENTIFICATION: REFER TO ELECTRICAL IDENTIFICATION FOR COLOR AND IDENTIFICATION LABELING REQUIREMENTS. 1.3 REFERENCES A.AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI): 1.ANSI C80.3 -ELECTRICAL METALLIC TUBING, ZINC-COATED AND FITTINGS 2.ANSI C80.4 -FITTINGS FOR RIGID METAL CONDUIT AND ELECTRICAL METALLIC TUBING 3.ANSI/NEMA OS 1 -SHEET-STEEL OUTLET BOXES, DEVICE BOXES, COVERS AND BOX SUPPORTS B.FEDERAL SPECIFICATIONS (FS): 1.A-A-50553A -FITTINGS FOR CONDUIT, METAL, RIGID, (THICK-WALL AND THIN-WALL (EMT) TYPE 2.A-A-55810 -SPECIFICATION FOR FLEXIBLE METAL CONDUIT C.NECA "STANDARDS OF INSTALLATION" D.NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA): 1.ANSI/NEMA FB 1 -FITTINGS, CAST METAL BOXES, AND CONDUIT BODIES FOR CONDUIT, ELECTRICAL METALLIC TUBING AND CABLE E.CEC CALIFORNIA ELECTRICAL CODE F.UNDERWRITERS LABORATORIES (UL): APPLICABLE LISTINGS 1.UL 1 -FLEXIBLE METAL CONDUIT 2.UL514-B -CONDUIT TUBING AND CABLE FITTINGS 3.UL797 -ELECTRICAL METAL TUBING G.DEFINITIONS: 1.FITTINGS: CONDUIT CONNECTION OR COUPLING. 2.BODY: ENLARGED FITTINGS WITH OPENING ALLOWING ACCESS TO THE CONDUCTORS FOR PULLING PURPOSES ONLY. 3.FINISHED SPACES: ENCLOSED AREAS WHERE THE PRIMARY USE IS TO HOUSE PERSONNEL AND THE GENERAL PUBLIC. THESE SPACES GENERALLY HAVE ARCHITECTURALLY EMPHASIZED FINISHES, CEILINGS AND/OR FLOORS. 4.CONCEALED: NOT VISIBLE BY THE GENERAL PUBLIC. OFTEN INDICATES A LOCATION EITHER ABOVE THE CEILING, IN THE WALLS, IN OR BENEATH THE FLOOR SLAB, IN COLUMN COVERINGS, OR IN THE CEILING CONSTRUCTION. PART 2 -PRODUCTS 2.1 ELECTRICAL METALLIC TUBING (EMT) AND FITTINGS A.MINIMUM SIZE ELECTRICAL METALLIC TUBING: 3/4 INCH, UNLESS OTHERWISE NOTED. B.MANUFACTURERS OF EMT CONDUIT: 1.ALLIED 2.CALBOND CALPIPE 3.LTV 4.STEELDUCT 5.WHEATLAND TUBE CO 6.OR APPROVED EQUAL. C.FITTINGS AND CONDUIT BODIES: 1.2" DIAMETER OR SMALLER: STEEL SET SCREW TYPE OF STEEL DESIGNED FOR THEIR SPECIFIC APPLICATION. 2.3/4" CONDUIT: PUSH-ON CONNECTORS AND COUPLERS WITH LOCKING RING AND WASHER OF ZINC PLATED STEEL, LISTED FOR USE IN DRY LOCATIONS. 3.LARGER THAN 2": COMPRESSION TYPE OF STEEL DESIGNED FOR THEIR SPECIFIC APPLICATION. 4.MANUFACTURERS OF EMT CONDUIT FITTINGS: a.APPLETON ELECTRIC b.O-Z/GEDNEY CO. c.ELECTROLINE d.RACO e.BRIDGEPORT f.MIDWEST g.REGAL h.THOMAS & BETTS i.ORBIT INDUSTRIES j.OR APPROVED EQUAL. 2.2 FLEXIBLE METALLIC CONDUIT (FMC) AND FITTINGS A.MINIMUM SIZE GALVANIZED STEEL: 3/4 INCH, UNLESS OTHERWISE NOTED. LIGHTING BRANCH CIRCUIT WIRING TO AN INDIVIDUAL LUMINAIRE MAY BE A MANUFACTURED, UL LISTED 3/8" FLEXIBLE METAL CONDUIT AND FITTINGS WITH #14 AWG THHN CONDUCTORS AND AN INSULATED GROUND WIRE. MAXIMUM LENGTH OF 3/8" FMC SHALL BE SIX (6) FEET. B.MANUFACTURERS: 1.AMERICAN FLEX 2.ALFLEX 3.ELECTRI-FLEX CO 4.OR APPROVED EQUAL. C.CONSTRUCTION: FLEXIBLE STEEL, APPROVED FOR CONDUIT GROUND, ZINC COATED, THREADLESS TYPE FORMED FROM A CONTINUOUS LENGTH OF SPIRALLY WOUND, INTERLOCKED ZINC COATED STRIP STEEL. PROVIDE A SEPARATE EQUIPMENT GROUNDING CONDUCTOR WHEN USED FOR EQUIPMENT WHERE FLEXIBILITY IS REQUIRED. D.FITTINGS AND CONDUIT BODIES: 1.THREADLESS HINGED CLAMP TYPE, GALVANIZED ZINC COATED CADMIUM PLATED MALLEABLE CAST IRON OR SCREW -IN TYPE, DIE-CAST ZINC. 2.FITTINGS AND CONDUIT BODIES SHALL INCLUDE PLASTIC OR CAST METAL INSERTS SUPPLIED BY THE MANUFACTURER TO PROTECT CONDUCTORS FROM SHARP EDGES. 3.MANUFACTURERS: a.O-Z/GEDNEY CO. b.THOMAS & BETTS c.APPLETON ELECTRIC d.ELECTROLINE e.BRIDGEPORT f.MIDWEST g.REGAL h.ORBIT INDUSTRIES i.OR APPROVED EQUAL. 2.3 OUTLET BOXES A.SHEET METAL OUTLET BOXES: ANSI/NEMA OS 1; GALVANIZED STEEL, 16 GAUGE (APPROXIMATELY 0.0625 INCHES), WITH 1/2-INCH MALE FIXTURE STUDS WHERE REQUIRED. B.OUTLET BOXES FOR LUMINAIRES TO BE NOT LESS THAN 1-1/2" DEEP, DEEPER IF REQUIRED BY THE NUMBER OF WIRES OR CONSTRUCTION. THE BOX SHALL BE COORDINATED WITH SURFACE LUMINAIRES TO CONCEAL THE BOX FROM VIEW OR PROVIDE A FINISHED TRIM PLATE. C.SWITCH OUTLET BOXES FOR LOCAL LIGHT CONTROL SWITCHES, DIMMERS AND OCCUPANCY SENSORS SHALL BE 4 INCHES SQUARE BY 2-1/8 INCHES DEEP, WITH RAISED COVER TO FIT FLUSH WITH FINISH WALL LINE. MULTIPLE GANG SWITCH OUTLETS SHALL CONSIST OF THE REQUIRED NUMBER OF GANG BOXES APPROPRIATE TO THE QUANTITY OF SWITCHES COMPRISING THE GANG. WHERE WALLS ARE PLASTERED, PROVIDE A PLASTER RAISED COVER. WHERE SWITCH OUTLET BOXES OCCUR IN EXPOSED CONCRETE BLOCK WALLS, BOXES SHALL BE INSTALLED IN THE BLOCK CAVITY WITH A RAISED SQUARE EDGE TILE COVER OF SUFFICIENT DEPTH TO EXTEND OUT TO FACE OF BLOCK OR MASONRY BOXES. D.OUTLET BOXES FOR TELEPHONE SUBSTATIONS IN WALLS AND COLUMNS SHALL BE 4 INCHES SQUARE AND 2-1/8 INCHES DEEP WITH SINGLE GANG RAISED COVER TO FIT FLUSH WITH FINISHED WALL LINE EQUIPPED WITH FLUSH TELEPHONE PLATE. E.WALL OR COLUMN RECEPTACLE OUTLET BOXES SHALL BE 4 INCHES SQUARE WITH RAISED COVER TO FIT FLUSH WITH FINISHED WALL LINE. BOXES IN CONCRETE BLOCK WALLS SHALL BE INSTALLED THE SAME AS FOR SWITCH BOXES IN BLOCK WALLS. 2.4 JB; PULL AND JUNCTION BOXES A.SHEET METAL BOXES: ANSI/NEMA OS 1; GALVANIZED STEEL. B.SHEET METAL BOXES LARGER THAN 12 INCHES IN ANY DIMENSION THAT CONTAIN TERMINATIONS OR COMPONENTS: CONTINUOUS HINGED ENCLOSURE WITH 1/4 TURN LATCH AND WHITE BACK PANEL FOR MOUNTING TERMINAL BLOCKS AND ELECTRICAL COMPONENTS. C.FLANGED TYPE BOXES SHALL BE USED WHERE INSTALLED FLUSH IN WALL. 2.5 ROUGH-IN A.PROVIDE WITH ONE (1) FLUSH MOUNT DOUBLE GANG BOX WITH SINGLE GANG PLASTER RING AND APPROPRIATE COVER PLATE, B.CONDUIT STUBBED TO ABOVE THE LAY-IN CEILING. C.RI-TECH; TECHNOLOGY ROUGH-IN: 1.ROUGH-IN SHALL HAVE ONE (1) 1" CONDUIT. PART 3 -EXECUTION 3.1 CONDUIT INSTALLATION SCHEDULE AND SIZING A.IN THE EVENT THE LOCATION OF CONDUIT INSTALLATION REPRESENTS CONFLICTING INSTALLATION REQUIREMENTS AS SPECIFIED IN THE FOLLOWING SCHEDULE, A CLARIFICATION SHALL BE OBTAINED FROM THE ARCHITECT/ENGINEER. IF THIS CONTRACTOR IS UNABLE TO OBTAIN A CLARIFICATION AS OUTLINED ABOVE, CONCEALED RIGID GALVANIZED STEEL CONDUIT INSTALLED PER THESE SPECIFICATIONS AND THE ELECTRICAL CODE SHALL BE REQUIRED. B.INSTALLATION SCHEDULE: REFER TO DRAWINGS. C.CONDUIT AND CONDUCTOR SIZING SHALL BE COORDINATED TO LIMIT CONDUCTOR FILL TO LESS THAN 40%, MAINTAIN CONDUCTOR AMPERE CAPACITY AS REQUIRED BY THE ELECTRICAL CODE (TO INCLUDE ENLARGED CONDUCTORS DUE TO TEMPERATURE AND QUANTITY DERATING VALUES) AND TO PREVENT EXCESSIVE VOLTAGE DROP AND PULLING TENSION DUE TO LONG CONDUIT/CONDUCTOR LENGTHS. D.MINIMUM CONDUIT SIZE (UNLESS NOTED OTHERWISE): 1.ABOVE GRADE: 3/4 INCH. 2.TELECOMMUNICATION CONDUIT: 1 INCH. 3.CONTROLS CONDUIT: 1/2 INCH. E.CONDUIT SIZES SHALL CHANGE ONLY AT THE ENTRANCE OR EXIT TO A JUNCTION BOX, UNLESS SPECIFICALLY NOTED ON THE DRAWINGS. 3.2 CONDUIT ARRANGEMENT A.IN GENERAL, CONDUIT SHALL BE INSTALLED CONCEALED IN WALLS, IN FINISHED SPACES AND WHERE POSSIBLE OR PRACTICAL, OR AS NOTED OTHERWISE. CONDUIT SHALL BE INSTALLED PARALLEL OR PERPENDICULAR TO WALLS, CEILINGS, AND EXPOSED STRUCTURAL MEMBERS. IN UNFINISHED SPACES, MECHANICAL AND UTILITY AREAS, CONDUIT MAY RUN EITHER CONCEALED OR EXPOSED AS CONDITIONS DICTATE AND AS PRACTICAL UNLESS NOTED OTHERWISE ON DRAWINGS. B.CONDUIT SHALL NOT SHARE THE SAME CELL AS STRUCTURAL REINFORCEMENT IN MASONRY WALLS. C.CONTRACTOR SHALL ADAPT CONTRACTOR'S WORK TO THE JOB CONDITIONS AND MAKE SUCH CHANGES AS REQUIRED AND PERMITTED BY THE ARCHITECT/ENGINEER, SUCH AS MOVING TO CLEAR BEAMS AND JOISTS, ADJUSTING AT COLUMNS, AVOIDING INTERFERENCE WITH WINDOWS, ETC., TO PERMIT THE PROPER INSTALLATION OF OTHER MECHANICAL AND/OR ELECTRICAL EQUIPMENT. D.CONTRACTOR SHALL COOPERATE WITH ALL CONTRACTORS ON THE PROJECT. CONTRACTOR SHALL OBTAIN DETAILS OF OTHER CONTRACTOR'S WORK TO ENSURE FIT AND AVOID CONFLICT. ANY EXPENSE DUE TO THE FAILURE OF THIS CONTRACTOR TO DO SO SHALL BE PAID FOR IN FULL BY CONTRACTOR. THE OTHER TRADES INVOLVED AS DIRECTED BY THE ARCHITECT/ENGINEER SHALL PERFORM THE REPAIR OF WORK DAMAGED AS A RESULT OF NEGLECT OR ERROR BY THIS CONTRACTOR. THE RESULTANT COSTS SHALL BE BORNE BY THIS CONTRACTOR. 3.3 CONDUIT SUPPORT A.CONDUIT RUNS INSTALLED ABOVE A SUSPENDED CEILING SHALL BE PROPERLY SUPPORTED. IN NO CASE SHALL CONDUIT REST ON THE SUSPENDED CEILING CONSTRUCTION, NOR UTILIZE CEILING SUPPORT SYSTEM FOR CONDUIT SUPPORT. 1.SUPPORT WIRE USED TO INDEPENDENTLY SUPPORT RACEWAY AND WIRING SYSTEMS ABOVE SUSPENDING CEILINGS SHALL BE SUPPORTED ON BOTH ENDS, MINIMUM 12 GAUGE SUSPENDED CEILING SUPPORT WIRE, AND DISTINGUISHABLE FROM CEILING SUPPORT SYSTEMS BY COLOR (FIELD PAINT), TAGGING, OR EQUIVALENT MEANS. B.CONDUIT SHALL NOT BE SUPPORTED FROM DUCTWORK, WATER, SPRINKLER PIPING, OR OTHER NON-STRUCTURAL MEMBERS, UNLESS APPROVED BY THE ARCHITECT/ENGINEER. ALL SUPPORTS SHALL BE FROM STRUCTURAL SLABS, WALLS, STRUCTURAL MEMBERS, AND BAR JOISTS, AND COORDINATED WITH ALL OTHER APPLICABLE CONTRACTORS, UNLESS NOTED OTHERWISE. C.CONDUIT SHALL BE HELD IN PLACE BY THE CORRECT SIZE OF GALVANIZED ONE-HOLE CONDUIT CLAMPS, TWO-HOLE CONDUIT STRAPS, PATENTED SUPPORT DEVICES, CLAMP BACK CONDUIT HANGERS, OR BY OTHER MEANS IF CALLED FOR ON THE DRAWINGS. D.SUPPORT INDIVIDUAL HORIZONTAL RACEWAYS WITH SEPARATE, MALLEABLE-IRON PIPE HANGERS OR CLAMPS. E.SPRING-STEEL CONDUIT CLIPS SPECIFICALLY DESIGNED FOR SUPPORTING SINGLE CONDUITS OR TUBING MAY BE USED IN LIEU OF MALLEABLE-IRON HANGERS FOR 1" AND SMALLER RACEWAYS SERVING LIGHTING AND RECEPTACLE BRANCH CIRCUITS ABOVE ACCESSIBLE CEILINGS AND FOR SECURING RACEWAYS TO SLOTTED CHANNEL AND ANGLE SUPPORTS. F.GROUP CONDUITS IN PARALLEL RUNS WHERE PRACTICAL AND USE CONDUIT RACKS OR TRAPEZE HANGERS CONSTRUCTED OF STEEL CHANNEL, SUSPENDED WITH THREADED SOLID RODS OR WALL MOUNTED FROM METAL CHANNELS WITH CONDUIT STRAPS OR CLAMPS. PROVIDE SPACE IN EACH RACK OR TRAPEZE FOR 25% ADDITIONAL CONDUITS. G.DO NOT EXCEED 25 LBS. PER HANGER AND A MINIMUM SPACING OF 2'-0" ON CENTER WHEN ATTACHING TO METAL ROOF DECKING (EXCLUDES CONCRETE ON METAL DECK). THIS 25 LBS. LOAD AND 2'-0" SPACING INCLUDE ADJACENT ELECTRICAL AND MECHANICAL ITEMS HANGING FROM DECK. IF THE HANGER RESTRICTIONS CANNOT BE ACHIEVED, SUPPLEMENTAL FRAMING OFF STEEL FRAMING WILL NEED TO BE ADDED. H.ARRANGE SUPPORTS IN VERTICAL RUNS SO THE WEIGHT OF RACEWAYS AND ENCLOSED CONDUCTORS IS CARRIED ENTIRELY BY RACEWAY SUPPORTS, WITH NO WEIGHT LOAD ON RACEWAY TERMINALS. I.SUPPORTS FOR METALLIC CONDUIT SHALL BE NO GREATER THAN 10 FEET. A SMALLER INTERVAL MAY BE USED IF NECESSITATED BY BUILDING CONSTRUCTION, BUT IN NO EVENT SHALL SUPPORT SPANS EXCEED THE ELECTRICAL CODE REQUIREMENTS. CONDUIT SHALL BE SECURELY FASTENED WITHIN 3 FEET OF EACH OUTLET BOX, JUNCTION BOX, DEVICE BOX, CABINET, OR FITTING. J.SUPPORTS OF FLEXIBLE CONDUIT SHALL BE WITHIN 12 INCHES OF EACH OUTLET BOX, JUNCTION BOX, DEVICE BOX, CABINET, OR FITTING AND AT INTERVALS NOT TO EXCEED 4.5 FEET. K.FINISH: 1.TRIM ALL ENDS OF EXPOSED FIELD FABRICATED STEEL HANGERS, SLOTTED CHANNEL AND THREADED ROD TO WITHIN 1" OF SUPPORT OR FASTENER TO ELIMINATE POTENTIAL INJURY TO PERSONNEL UNLESS SHOWN OTHERWISE ON THE DRAWINGS. SMOOTH ENDS AND INSTALL ELASTOMERIC INSULATION WITH TWO COATS OF LATEX PAINT IF EXPOSED STEEL IS WITHIN 6'-6" OF FINISH FLOOR AND PRESENTS POTENTIAL INJURY TO PERSONNEL. 3.4 CONDUIT INSTALLATION A.CONDUIT CONNECTIONS: 1.SHORTER THAN STANDARD CONDUIT LENGTHS SHALL BE CUT SQUARE USING INDUSTRY STANDARDS. THE ENDS OF ALL CONDUITS CUT SHALL BE REAMED OR OTHERWISE FINISHED TO REMOVE ALL ROUGH EDGES. 2.WHERE CONDUITS WITH TAPERED THREADS CANNOT BE COUPLED WITH STANDARD COUPLINGS, THEN APPROVED SPLIT OR ERICKSON COUPLINGS SHALL BE USED. RUNNING THREADS WILL NOT BE PERMITTED. 3.INSTALL EXPANSION/DEFLECTION JOINTS WHERE CONDUIT CROSSES STRUCTURE EXPANSION/SEISMIC JOINTS. B.CONDUIT TERMINATIONS FOR ALL LOW VOLTAGE WIRING SHALL HAVE NYLON BUSHINGS INSTALLED ON EACH END OF EVERY CONDUIT RUN. C.CONDUIT BENDS: 1.USE A HYDRAULIC ONE-SHOT CONDUIT BENDER OR FACTORY ELBOWS FOR BENDS IN CONDUIT 2" IN SIZE OR LARGER. ALL STEEL CONDUIT BENDING SHALL BE DONE COLD; NO HEATING OF STEEL CONDUIT SHALL BE PERMITTED. 2.A RUN OF CONDUIT SHALL NOT CONTAIN MORE THAN THE EQUIVALENT OF FOUR (4) QUARTER BENDS (360°), INCLUDING THOSE BENDS LOCATED IMMEDIATELY AT THE OUTLET OR BODY. 3.TELECOMMUNICATIONS CONDUITS SHALL HAVE NO MORE THAN TWO (2) 90-DEGREE BENDS BETWEEN PULL POINTS AND CONTAIN NO CONTINUOUS SECTIONS LONGER THAN 100 FEET. INSERT PULL POINTS OR PULL BOXES FOR CONDUITS EXCEEDING 100 FEET IN LENGTH. a.A THIRD BEND IS ACCEPTABLE IF: 1)THE TOTAL RUN IS NOT LONGER THAN (33) FEET. 2)THE CONDUIT SIZE IS INCREASED TO THE NEXT TRADE SIZE. 4.TELECOMMUNICATIONS PULL BOXES SHALL NOT BE USED IN LIEU OF A BEND. ALIGN CONDUITS THAT ENTER THE PULL BOX FROM OPPOSITE ENDS WITH EACH OTHER. PULL BOX SIZE SHALL BE TWELVE (12) TIMES THE DIAMETER OF THE LARGEST CONDUIT. SLIP SLEEVES OR GUTTERS CAN BE USED IN PLACE OF A PULL BOX. 5.TELECOMMUNICATIONS CONDUIT(S): MAINTAIN APPROPRIATE CONDUIT BEND RADIUS AT ALL TIMES. FOR CONDUITS WITH AN INTERNAL DIAMETER OF LESS THAN 2", MAINTAIN A BEND RADIUS OF AT LEAST 6 TIMES THE INTERNAL DIAMETER. FOR CONDUITS WITH AN INTERNAL DIAMETER 2" OR GREATER, MAINTAIN A BEND RADIUS OF AT LEAST 10 TIMES THE INTERNAL DIAMETER. 6.USE CONDUIT BODIES TO MAKE SHARP CHANGES IN DIRECTION (I.E. AROUND BEAMS). D.CONDUIT PLACEMENT: 1.CONDUIT SHALL BE MECHANICALLY CONTINUOUS FROM SOURCE OF CURRENT TO ALL OUTLETS. CONDUIT SHALL BE ELECTRICALLY CONTINUOUS FROM SOURCE OF CURRENT TO ALL OUTLETS, UNLESS A PROPERLY SIZED GROUNDING CONDUCTOR IS ROUTED WITHIN THE CONDUIT. ALL METALLIC CONDUITS SHALL BE BONDED PER THE ELECTRICAL CODE. 2.ROUTE EXPOSED CONDUIT AND CONDUIT ABOVE SUSPENDED CEILINGS (ACCESSIBLE OR NOT) PARALLEL/PERPENDICULAR TO THE BUILDING STRUCTURAL LINES, AND AS CLOSE TO BUILDING STRUCTURE AS POSSIBLE. WHEREVER POSSIBLE, ROUTE HORIZONTAL CONDUIT RUNS ABOVE WATER AND STEAM PIPING. 3.AVOID MOISTURE TRAPS WHERE POSSIBLE. WHERE UNAVOIDABLE, PROVIDE A JUNCTION BOX WITH DRAIN FITTING AT CONDUIT LOW POINT. 4.CONTRACTOR SHALL PROVIDE SUITABLE MECHANICAL PROTECTION AROUND ALL CONDUITS STUBBED OUT FROM FLOORS, WALLS OR CEILINGS DURING CONSTRUCTION TO PREVENT BENDING OR DAMAGING OF STUBS DUE TO CARELESSNESS WITH CONSTRUCTION EQUIPMENT. 5.CONTRACTOR SHALL PROVIDE A POLYPROPYLENE PULL CORD WITH 2000 LBS. TENSILE STRENGTH IN EACH EMPTY CONDUIT (INDOOR AND OUTDOOR), EXCEPT IN SLEEVES AND NIPPLES. 6.TELECOMMUNICATIONS CONDUITS THAT ENTER INTO TELECOMMUNICATIONS ROOMS BELOW THE FINISHED CEILING SHALL TERMINATE A MINIMUM OF 4" BELOW CEILING AND AS CLOSE TO THE WALL AS POSSIBLE. 7.TELECOMMUNICATIONS CONDUITS THAT ARE BELOW GRADE AND ENTER INTO A BUILDING SHALL TERMINATE A MINIMUM OF 4" ABOVE FINISHED FLOOR (AFF) AND AS CLOSE TO THE WALL AS POSSIBLE. 3.5 CONDUIT TERMINATIONS A.WHERE CONDUIT BONDING IS INDICATED OR REQUIRED IN THE CONTRACT DOCUMENTS, THE BUSHINGS SHALL BE A GROUNDING TYPE SIZED FOR THE CONDUIT AND GROUND BONDING CONDUCTOR AS MANUFACTURED BY O-Z/GEDNEY, APPLETON, THOMAS & BETTS, BURNDY, REGAL, ORBIT INDUSTRIES OR APPROVED EQUAL. B.CONDUITS WITH TERMINATION FITTINGS SHALL BE THREADED FOR ONE (1) LOCK NUT ON THE OUTSIDE AND ONE (1) LOCK NUT AND BUSHING ON THE INSIDE OF EACH BOX. C.WHERE CONDUITS TERMINATE IN BOXES WITH KNOCKOUTS, THEY SHALL BE SECURED TO THE BOXES WITH LOCK NUTS AND PROVIDED WITH APPROVED SCREW TYPE TINNED IRON BUSHINGS OR FITTINGS WITH PLASTIC INSERTS. D.WHERE CONDUITS TERMINATE IN BOXES, FITTINGS, OR BODIES WITH THREADED OPENINGS, THEY SHALL BE TIGHTLY SCREWED AGAINST THE SHOULDER PORTION OF THE THREADED OPENINGS. E.ALL CONDUIT ENDS SHALL BE SEALED WITH PLASTIC IMMEDIATELY AFTER INSTALLATION TO PREVENT THE ENTRANCE OF ANY FOREIGN MATTER DURING CONSTRUCTION. THE SEALS SHALL BE REMOVED AND THE CONDUITS BLOWN CLEAR OF ALL FOREIGN MATTER PRIOR TO ANY WIRES OR PULL CORDS BEING INSTALLED. 3.6 BOX INSTALLATION SCHEDULE A.GALVANIZED STEEL BOXES MAY BE USED IN: 1.CONCEALED INTERIOR LOCATIONS ABOVE CEILINGS AND IN HOLLOW STUDDED PARTITIONS. 2.EXPOSED INTERIOR LOCATIONS IN MECHANICAL ROOMS AND IN ROOMS WITHOUT CEILINGS; HIGHER THAN 8' ABOVE THE HIGHEST PLATFORM LEVEL. 3.7 COORDINATION OF BOX LOCATIONS A.PROVIDE ELECTRICAL BOXES AS SHOWN ON THE DRAWINGS, AND AS REQUIRED FOR SPLICES, TAPS, WIRE PULLING, EQUIPMENT CONNECTIONS, AND CODE COMPLIANCE. B.ELECTRICAL BOX LOCATIONS SHOWN ON THE CONTRACT DRAW INGS ARE APPROXIMATE, UNLESS DIMENSIONED. VERIFY LOCATION OF FLOOR BOXES AND OUTLETS IN OFFICES AND WORK AREAS PRIOR TO ROUGH-IN. C.LOCATE AND INSTALL BOXES TO ALLOW ACCESS. AVOID INTERFERENCES WITH DUCTWORK, PIPING, STRUCTURE, EQUIPMENT, ETC. RECESSED LUMINAIRES SHALL NOT BE USED AS ACCESS TO OUTLET, PULL, AND JUNCTION BOXES. WHERE INSTALLATION IS INACCESSIBLE, PROVIDE ACCESS DOORS. COORDINATE LOCATIONS AND SIZES OF REQUIRED ACCESS DOORS WITH THE ARCHITECT/ENGINEER AND GENERAL CONTRACTOR. D.LOCATE AND INSTALL TO MAINTAIN HEADROOM AND TO PRESENT A NEAT APPEARANCE. 3.8 OUTLET BOX INSTALLATION A.DO NOT INSTALL BOXES BACK-TO-BACK IN WALLS. 1.PROVIDE A MINIMUM HORIZONTAL SEPARATION OF 6 INCHES BETWEEN BOXES INSTALLED ON OPPOSITE SIDES OF NON-RATED STUD WALLS. 2.PROVIDE A MINIMUM HORIZONTAL SEPARATION OF 24 INCHES BETWEEN BOXES INSTALLED ON OPPOSITE SIDES OF FIRE-RATED WALLS. WHEN THE MINIMUM SEPARATION CANNOT BE MAINTAINED, THE BOX IS GREATER THAN 16 SQUARE INCHES OR THE TOTAL BOX AREA (ALL TRADES) PER 100 SQUARE FEET IS GREATER THAN OR EQUAL TO 100 SQUARE INCHES, INSTALL FIRE-RATED MOLDABLE PADS TO ALL FIVE SIDES OF THE BACK BOX TO MAINTAIN THE FIRE RATING OF THE WALL. INSTALL MOLDABLE PADS IN ACCORDANCE WITH UL LISTING FOR THE SPECIFIC PRODUCT. SOUND INSULATION PADS ARE NOT ACCEPTABLE FOR USE IN FIRE-RATED WALL APPLICATIONS UNLESS THE PRODUCT CARRIES THE NECESSARY FIRE RATING. B.THE CONTRACTOR SHALL ANCHOR SWITCH AND OUTLET BOX TO WALL CONSTRUCTION SO THAT IT IS FLUSH WITH THE FINISHED MASONRY, PANELING, DRYWALL, PLASTER, ETC. THE CONTRACTOR SHALL CHECK THE BOXES AS THE FINISH WALL SURFACE IS BEING INSTALLED TO ASSURE THAT THE BOX IS FLUSH. (PROVIDE PLASTER RINGS AS NECESSARY.) C.MOUNT AT HEIGHTS SHOWN OR NOTED ON THE DRAWINGS OR AS GENERALLY ACCEPTED IF NOT SPECIFICALLY NOTED. D.PROVIDE KNOCKOUT CLOSURES FOR UNUSED OPENINGS. E.SUPPORT BOXES INDEPENDENTLY OF CONDUIT. F.USE MULTIPLE-GANG BOXES WHERE MORE THAN ONE DEVICE IS MOUNTED TOGETHER; DO NOT USE SECTIONAL BOXES. PROVIDE BARRIERS TO SEPARATE WIRING OF DIFFERENT VOLTAGE SYSTEMS. G.INSTALL BOXES IN WALLS WITHOUT DAMAGING WALL INSULATION. H.COORDINATE MOUNTING HEIGHTS AND LOCATIONS OF OUTLETS MOUNTED ABOVE COUNTERS, BENCHES, BACKSPLASHES, AND BELOW BASEBOARD RADIATION. I.PROVIDE RECESSED OUTLET BOXES IN FINISHED AREAS; SECURE BOXES TO INTERIOR WALL AND PARTITION STUDS, ACCURATELY POSITIONED TO ALLOW FOR SURFACE FINISH THICKNESS. USE STAMPED STEEL STUD BRIDGES FOR FLUSH OUTLETS IN HOLLOW STUD WALL, AND ADJUSTABLE STEEL CHANNEL FASTENERS FOR FLUSH CEILING OUTLET BOXES. J.ALIGN WALL-MOUNTED OUTLET BOXES FOR SWITCHES, THERMOSTATS, AND SIMILAR DEVICES. 3.9 JUNCTION BOX INSTALLATION A.LOCATE JUNCTION BOXES ABOVE ACCESSIBLE CEILINGS OR IN UNFINISHED AREAS. B.SUPPORT JUNCTION BOXES INDEPENDENT OF CONDUIT. C.DO NOT INSTALL BOXES BACK-TO-BACK IN WALLS. 1.PROVIDE A MINIMUM HORIZONTAL SEPARATION OF 6 INCHES BETWEEN BOXES INSTALLED ON OPPOSITE SIDES OF NON-RATED STUD WALLS. 2.PROVIDE A MINIMUM HORIZONTAL SEPARATION OF 24 INCHES BETWEEN BOXES INSTALLED ON OPPOSITE SIDES OF FIRE-RATED WALLS. WHEN THE MINIMUM SEPARATION CANNOT BE MAINTAINED, THE BOX IS GREATER THAN 16 SQUARE INCHES OR THE TOTAL BOX AREA (ALL TRADES) PER 100 SQUARE FEET IS GREATER THAN OR EQUAL TO 100 SQUARE INCHES, INSTALL FIRE-RATED MOLDABLE PADS TO ALL FIVE SIDES OF THE BACK BOX TO MAINTAIN THE FIRE RATING OF THE WALL. INSTALL MOLDABLE PADS IN ACCORDANCE WITH UL LISTING FOR THE SPECIFIC PRODUCT. SOUND INSULATION PADS ARE NOT ACCEPTABLE FOR USE IN FIRE-RATED WALL APPLICATIONS UNLESS THE PRODUCT CARRIES THE NECESSARY FIRE RATING. END OF SECTION No. Revisions Date pl a n c h e c k s u b m i t t a l TE OLIRFFOAC LANRP E 23191 STA ER REGIST ED INA N REENIGE FO OISSE E AICLCERTL Exp. 06/30/26 MIRASOPHOCLISGEORGY IMEG RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAW ING AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG AND SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG. ©2024 IMEG CONSULTANTS CORP. REF. SCALE IN INCHES 0 1 2 3 222 S. HARBOR BOULEVARD SUITE 800 ANAHEIM, CA 92805 P: 714.490.5555 F: 714.490.5560 The FUTURE. Built Smarter www.imegcorp.com PROJECT #24007312.00 0 5' GRAPHIC SCALES: Issue Date 1/16" = 1'-0" 50' 1/8" = 1'-0"1/4" = 1'-0"1/2" = 1'-0"3/4" = 1'-0"1" = 1'-0"1-1/2" = 1'-0"3" = 1'-0" 0 5'25' 0 1'12' 0 1'6' 0 4' 0 3'1'0 2' 0 1' Chckd By Drwn By Scale Building ID: KP Proj. No. Permit No. Sheet SheetsOf Sheet Title Project Facility This document is the property of the Owner and is Project Architect Approval: Architect/Engineer Of Record: IF THIS SHEET IS NOT 30"x42" , IT IS A REDUCED PRINT - SCALE ACCORDINGLY National Facilities Services Post Office Box 12916 Oakland California 94604 not to be used without owner's written permission. Floor Lev: Section: HGW Proj. No. © A R C H I T E C T S h a n n a g a b r i e l w e l l s , a l l r i g h t s r e s e r v ed . A n y u s e w i t h o u t p e r m i s s i o n i s e x p r e s s l y p r o h i b i t ed . P l o t t e d CAP029271 1955 Bacon Street. San Diego, CA 92107 Office 619 523 8487 www.hgwarchitecture.com PROJECT #24007312.00 Revisions By Appr. KAISER HARBOR MACARTHUR MOB EXTERIOR SIGNAGE KAISER PERMANENTE HARBOR MACARTHUR MOB 1/ 2 3 / 2 0 2 6 1 2 : 4 5 : 5 3 P M 01/23/2026 MG CL ES004 ELECTRICAL SPECIFICATIONS 3401 South Harbor Boulevard, Santa Ana, CA 92704 10 0 % C D S E T 2441 ELECTRICAL SPECIFICATIONS TABLE OF CONTENT • SECTION 26 05 53 -ELECTRICAL IDENTIFICATION SECTION 26 05 53 -ELECTRICAL IDENTIFICATION PART 1 -GENERAL 1.1 SECTION INCLUDES A.ADHESIVE MARKINGS AND FIELD LABELS B.NAMEPLATES AND SIGNS C.PRODUCT COLORS 1.2 REFERENCES A.NFPA 70E -NATIONAL ELECTRICAL SAFETY CODE B.CEC CALIFORNIA ELECTRICAL CODE C.ANSI A13.1 -STANDARD FOR PIPE IDENTIFICATION D.ANSI Z535.4 -STANDARD FOR PRODUCT SAFETY SIGNS AND LABELS 1.3 QUALITY ASSURANCE A.ELECTRICAL IDENTIFICATION PRODUCTS SHALL BE SUITABLE FOR THE ENVIRONMENT INSTALLED. IDENTIFICATION LABELS DAMAGED BY THE ENVIRONMENT DUE TO ULTRAVIOLET LIGHT FADING, DAMP OR WET CONDITIONS, PHYSICAL DAMAGE, CORROSION, OR OTHER CONDITIONS SHALL BE REPLACED WITH LABELS SUITABLE FOR THE ENVIRONMENT. PART 2 -PRODUCTS 2.1 ADHESIVE MARKINGS AND FIELD LABELS A.ADHESIVE MARKING LABELS FOR RACEWAY: PRE-PRINTED, FLEXIBLE, SELF-ADHESIVE VINYL LABELS WITH LEGEND INDICATING VOLTAGE AND SERVICE (EMERGENCY, LIGHTING, POWER, HVAC, COMMUNICATIONS, CONTROL, FIRE). 1.LABEL SIZE AS FOLLOWS: a.RACEWAYS: KROY OR BROTHER LABELS 1-INCH (25MM) HIGH BY 12-INCHES (305MM) LONG (MINIMUM). 2.COLOR: AS SPECIFIED FOR VARIOUS SYSTEMS. B.COLORED ADHESIVE MARKING TAPE FOR BANDING RACEWAYS, WIRES, AND CABLES: SELF-ADHESIVE VINYL TAPE NOT LESS THAN 3 MILS THICK BY 1 INCH (25MM) TO 2 INCHES (50MM) IN WIDTH. C.WIRE/CABLE DESIGNATION TAPE MARKERS: VINYL OR VINYL-CLOTH, SELF-ADHESIVE, WRAPAROUND, CABLE/CONDUCTOR MARKERS WITH PREPRINTED NUMBERS AND LETTER. 2.2 PRODUCT COLORS A.NAMEPLATES AND SIGNS: 1.NORMAL POWER: BLACK LETTERS ON WHITE FACE 2.CONTROL LABELS: BLACK LETTERS ON WHITE FACE B.RACEWAYS AND CONDUIT: 1.PROVIDE COLOR CODED CONDUIT AS INDICATED BELOW. CONDUIT SHALL BE COLORED BY THE MANUFACTURER: a.NORMAL POWER AND GENERAL DISTRIBUTION: SILVER b.EMERGENCY POWER DISTRIBUTION SYSTEM: 1)ALL EMERGENCY: ORANGE c.FIRE ALARM SYSTEM: RED d.LOW VOLTAGE AND TELEPHONE: PURPLE C.BOX COVERS: 1.BOX COVERS SHALL BE PAINTED TO CORRESPOND WITH SYSTEM TYPE AS FOLLOWS: a.NORMAL POWER AND GENERAL: SILVER b.EMERGENCY POWER AND DISTRIBUTION: 1)ALL EMERGENCY: ORANGE c.FIRE ALARM SYSTEM: RED d.GROUND: GREEN e.LOW VOLTAGE AND TELEPHONE: PURPLE 2.BOX COVER COLORS SHALL MATCH CONDUIT COLORS LISTED ABOVE. D.CONDUCTOR COLOR IDENTIFICATION: REFER TO PART 3 FOR ADDITIONAL INFORMATION. PART 3 -EXECUTION 3.1 INSTALLATION A.LETTERING AND GRAPHICS: COORDINATE NAMES, ABBREVIATIONS, COLORS, AND OTHER DESIGNATIONS USED IN ELECTRICAL IDENTIFICATION WORK WITH CORRESPONDING DESIGNATIONS SPECIFIED OR INDICATED. INSTALL NUMBERS, LETTERING, AND COLORS AS APPROVED IN SUBMITTALS AND AS REQUIRED BY CODE. B.EXPOSED CEILINGS AND FINISHED SPACES: THE PROJECT INCLUDES EXPOSED CEILINGS IN FINISHED SPACES. THE INSTALLATION OF COLORED RACEWAYS AND LABELING MAY NOT BE AESTHETICALLY DESIRABLE IN FINISHED SPACES. THE CONTRACTOR SHALL COORDINATE IDENTIFICATION REQUIREMENTS IN EXPOSED CEILINGS OF FINISHED SPACES WITH THE A/E PRIOR TO INSTALLATION AND ORDERING OF MATERIALS. C.INSTALL IDENTIFICATION DEVICES IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTION AND REQUIREMENTS OF ELECTRICAL CODE. D.SEQUENCE OF WORK: WHERE IDENTIFICATION IS TO BE APPLIED TO SURFACES THAT REQUIRE FINISH, INSTALL IDENTIFICATION AFTER COMPLETION OF FINISH WORK. ALL MOUNTING SURFACES SHALL BE CLEANED AND DEGREASED PRIOR TO IDENTIFICATION INSTALLATION. E.CIRCUIT IDENTIFICATION: TAG OR LABEL CONDUCTORS AS FOLLOWS: 1.MULTIPLE POWER OR LIGHTING CIRCUITS IN SAME ENCLOSURE: WHERE MULTIPLE BRANCH CIRCUITS ARE TERMINATED OR SPLICED IN A BOX OR ENCLOSURE, LABEL EACH CONDUCTOR WITH SOURCE AND CIRCUIT NUMBER. 2.MULTIPLE CONTROL WIRING AND COMMUNICATION/SIGNAL CIRCUITS IN SAME ENCLOSURE: FOR CONTROL AND COMMUNICATIONS/SIGNAL WIRING, USE WIRE/CABLE MARKING TAPE AT TERMINATIONS IN WIRING BOXES, TROUGHS, AND CONTROL CABINETS. USE CONSISTENT LETTER/NUMBER CONDUCTOR DESIGNATIONS THROUGHOUT ON WIRE/CABLE MARKING TAPE. 3.MATCH IDENTIFICATION MARKINGS WITH DESIGNATIONS USED IN PANELBOARDS SHOP DRAWINGS, CONTRACT DOCUMENTS, AND SIMILAR PREVIOUSLY ESTABLISHED IDENTIFICATION SCHEMES FOR THE FACILITY'S ELECTRICAL INSTALLATIONS. F.INSTALL LABELS PARALLEL TO EQUIPMENT LINES AT LOCATIONS AS REQUIRED AND AT LOCATIONS FOR BEST CONVENIENCE OF VIEWING WITHOUT INTERFERENCE WITH OPERATION AND MAINTENANCE OF EQUIPMENT. 3.2 FEEDER AND BRANCH CIRCUIT DIRECTORIES A.PRODUCT: 1.ADHESIVE LABELS AND FIELD MARKINGS 2.NAMEPLATES AND SIGNS B.FEEDER DIRECTORIES BRANCH: PROVIDE EACH FEEDER, BRANCH CIRCUIT, FEEDER MODIFICATION, AND BRANCH CIRCUIT MODIFICATION WITH A TYPED CIRCUIT DIRECTORY LABEL. REFER TO TECHNICAL EQUIPMENT SPECIFICATION SECTIONS FOR ADDITIONAL REQUIREMENTS. INCLUDE THE FOLLOWING WITH EACH LABEL: 1.LOAD DESCRIPTION: LIGHTING, RECEPTACLES, SPECIFIC EQUIPMENT, SPARE, SPACE, OR SIMILAR DESCRIPTION. 2.LOCATION: ROOM NAME, NUMBER, LOCATION. C.PROVIDE A FACTORY OR CUSTOM CLEAR PLASTIC SLEEVE FOR EACH BRANCH PANEL DIRECTORY AND SECURE TO INSIDE PANEL COVER. 3.3 LIGHTING CONTROL AND RECEPTACLE COVER PLATES A.IDENTIFICATION TO BE ENGRAVED DIRECTLY ON THE STAINLESS STEEL COVERPLATES. LETTER AND NUMBER SIZE TO 1/8-INCH (3MM) HIGH. B.PROVIDE IDENTIFICATION ON ALL SWITCH AND RECEPTACLE COVER PLATES. IDENTIFICATION SHALL INDICATE SOURCE AND CIRCUIT NUMBER SERVING THE DEVICE (E.G. "C1A -24"). 3.4 CONDUIT AND EXPOSED CABLE LABELING A.PRODUCT: 1.ADHESIVE LABELS AND FIELD MARKINGS B.CONDUIT IDENTIFICATION: PRE-PRINTED, FLEXIBLE, SELF-ADHESIVE VINYL LABELS WITH LEGEND AT 20 FOOT (6 METER) INTERVALS TO IDENTIFY ALL CONDUITS RUN EXPOSED OR LOCATED ABOVE ACCESSIBLE CEILINGS. CONDUITS LOCATED ABOVE NON-ACCESSIBLE CEILING OR IN FLOORS AND WALLS SHALL BE LABELED WITHIN 3 FEET OF BECOMING ACCESSIBLE, OR SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, AND FLOORS. LABELS FOR MULTIPLE CONDUITS SHALL BE ALIGNED. REFER TO COLOR REQUIREMENTS IN PART 2 WHEN APPLICABLE IN ADDITION TO THE FOLLOWING: 1.1000 VOLT OR LESS NORMAL/EMERGENCY POWER: INDICATE FEEDER IDENTIFICATION AND VOLTAGE. 2.FIRE ALARM: INDICATE "FIRE ALARM". 3.GROUNDING: INDICATE "GROUND" AND EQUIPMENT AND DESIGNATION. 4.TELEPHONE SYSTEM: INDICATE "TELEPHONE". C.BLANK CONDUIT ENDS OR OUTLET BOXES FOR FUTURE EXTENSION OF SYSTEM SHALL HAVE PERMANENT IDENTIFICATION MARKER INDICATING PURPOSE OF CONDUIT OR BOX AND WHERE THE RACEWAY ORIGINATED. 3.5 BOX LABELING A.PRODUCTS: 1.ADHESIVE LABELS AND FIELD MARKINGS B.IDENTIFY JUNCTION, PULL AND CONNECTION BOXES: LABELING SHALL BE 3/8-INCH (10MM) KROY TAPE OR BROTHER SELF-LAMINATING VINYL LABEL, LETTERS/NUMBERS COLOR CODED SAME AS CONDUITS. IN ROOMS THAT ARE PAINTED OUT, PROVIDE LABELING ON INSIDE OF COVER. C.ALL JUNCTION, PULL, AND CONNECTION BOXES SHALL BE IDENTIFIED AS FOLLOWS: 1.FOR POWER AND LIGHTING CIRCUITS, INDICATE SYSTEM VOLTAGE AND IDENTITY OF CONTAINED CIRCUITS ("120V, 1LA1-3,5,7"). 2.FOR OTHER WIRING, INDICATE SYSTEM TYPE AND DESCRIPTION OF WIRING ("FIRE ALARM NAC #1"). 3.6 CONDUCTOR COLOR CODING A.PRODUCTS: 1.ALL WIRE AND CABLES SHALL BE COLOR CODED BY THE MANUFACTURER. 2.WIRE AND CABLES SMALLER THAN 6 AWG SHALL BE COLOR CODED BY THE MANUFACTURER. B.WHERE MORE THAN ONE NOMINAL VOLTAGE SYSTEM EXISTS IN A BUILDING OR FACILITY, EACH UNGROUNDED CONDUCTOR OF A MULTI-WIRE BRANCH CIRCUIT, WHERE ACCESSIBLE, SHALL BE IDENTIFIED BY PHASE AND SYSTEM. C.CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: 1.208Y/120 VOLT, 4-WIRE: a.A-PHASE -BLACK b.B-PHASE -RED c.C-PHASE -BLUE d.NEUTRAL -WHITE e.GROUND BOND -GREEN 2.480Y/277 VOLT, 4-WIRE: a.A-PHASE -BROWN b.B-PHASE -ORANGE c.C-PHASE -YELLOW d.NEUTRAL -GRAY e.GROUND BOND -GREEN 3.GROUNDING CONDUCTORS: a.EQUIPMENT GROUNDING CONDUCTORS, MAIN/SYSTEM/SUPPLY-SIDE BONDING JUMPERS: GREEN. 4.CABLING FOR REMOTE CONTROL, SIGNAL, AND POWER LIMITED CIRCUITS: a.FIRE ALARM: REFER TO FIRE ALARM AND AUTOMATIC DETECTION SECTION 28 31 00 FOR CABLE COLOR REQUIREMENTS. b.LOW VOLTAGE SWITCHING: PER MANUFACTURER RECOMMENDATIONS AND CODE REQUIREMENTS. END OF SECTION No. Revisions Date pl a n c h e c k s u b m i t t a l CORRD 2101 VESEL 2108 VESTI 2104 TLPUB 2106 TLPUB 2105 WTAGN 2123 CORRD 2126 CORRD 2100 AREA OF WORK AREA OF WORK_____03 ES122 _____04 ES122 _____01 ES122 AREA OF WORK _____02 ES122 TE OLIRFFOAC LANRP E 23191 STA ER REGIST ED INA N REENIGE FO OISSE E AICLCERTL Exp. 06/30/26 MIRASOPHOCLISGEORGY IMEG RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAW ING AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG AND SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG. ©2024 IMEG CONSULTANTS CORP. REF. SCALE IN INCHES 0 1 2 3 222 S. HARBOR BOULEVARD SUITE 800 ANAHEIM, CA 92805 P: 714.490.5555 F: 714.490.5560 The FUTURE. Built Smarter www.imegcorp.com PROJECT #24007312.00 0 5' GRAPHIC SCALES: Issue Date 1/16" = 1'-0" 50' 1/8" = 1'-0"1/4" = 1'-0"1/2" = 1'-0"3/4" = 1'-0"1" = 1'-0"1-1/2" = 1'-0"3" = 1'-0" 0 5'25' 0 1'12' 0 1'6' 0 4' 0 3'1'0 2' 0 1' Chckd By Drwn By Scale Building ID: KP Proj. No. Permit No. Sheet SheetsOf Sheet Title Project Facility This document is the property of the Owner and is Project Architect Approval: Architect/Engineer Of Record: IF THIS SHEET IS NOT 30"x42" , IT IS A REDUCED PRINT - SCALE ACCORDINGLY National Facilities Services Post Office Box 12916 Oakland California 94604 not to be used without owner's written permission. Floor Lev: Section: HGW Proj. No. © A R C H I T E C T S h a n n a g a b r i e l w e l l s , a l l r i g h t s r e s e r v ed . A n y u s e w i t h o u t p e r m i s s i o n i s e x p r e s s l y p r o h i b i t ed . P l o t t e d CAP029271 1955 Bacon Street. San Diego, CA 92107 Office 619 523 8487 www.hgwarchitecture.com PROJECT #24007312.00 Revisions By Appr. KAISER HARBOR MACARTHUR MOB EXTERIOR SIGNAGE KAISER PERMANENTE HARBOR MACARTHUR MOB 3/32" = 1'-0" 1/ 2 3 / 2 0 2 6 1 2 : 4 5 : 5 9 P M 01/23/2026 MG CL ES102 LEVEL 02 - ELECTRICAL PLAN - OVERALL 3401 South Harbor Boulevard, Santa Ana, CA 92704 10 0 % C D S E T 2441 3/32" = 1'-0"01 LEVEL 02 - ELECTRICAL - REMODEL PLAN - OVERALL 0 4'8'2' No. Revisions Date pl a n c h e c k s u b m i t t a l VESEL 3100 CORRD 3101 CORRD 3102 TLPUB 3104 TLPUB 3103 HALLW 3107 WTAGN 3108 '3PB2' -(E) AREA OF WORK AREA OF WORK_____01 ES123 _____02 ES123 AREA OF WORK TE OLIRFFOAC LANRP E 23191 STA ER REGIST ED INA N REENIGE FO OISSE E AICLCERTL Exp. 06/30/26 MIRASOPHOCLISGEORGY IMEG RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAW ING AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG AND SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG. ©2024 IMEG CONSULTANTS CORP. REF. SCALE IN INCHES 0 1 2 3 222 S. HARBOR BOULEVARD SUITE 800 ANAHEIM, CA 92805 P: 714.490.5555 F: 714.490.5560 The FUTURE. Built Smarter www.imegcorp.com PROJECT #24007312.00 0 5' GRAPHIC SCALES: Issue Date 1/16" = 1'-0" 50' 1/8" = 1'-0"1/4" = 1'-0"1/2" = 1'-0"3/4" = 1'-0"1" = 1'-0"1-1/2" = 1'-0"3" = 1'-0" 0 5'25' 0 1'12' 0 1'6' 0 4' 0 3'1'0 2' 0 1' Chckd By Drwn By Scale Building ID: KP Proj. No. Permit No. Sheet SheetsOf Sheet Title Project Facility This document is the property of the Owner and is Project Architect Approval: Architect/Engineer Of Record: IF THIS SHEET IS NOT 30"x42" , IT IS A REDUCED PRINT - SCALE ACCORDINGLY National Facilities Services Post Office Box 12916 Oakland California 94604 not to be used without owner's written permission. Floor Lev: Section: HGW Proj. No. © A R C H I T E C T S h a n n a g a b r i e l w e l l s , a l l r i g h t s r e s e r v ed . A n y u s e w i t h o u t p e r m i s s i o n i s e x p r e s s l y p r o h i b i t ed . P l o t t e d CAP029271 1955 Bacon Street. San Diego, CA 92107 Office 619 523 8487 www.hgwarchitecture.com PROJECT #24007312.00 Revisions By Appr. KAISER HARBOR MACARTHUR MOB EXTERIOR SIGNAGE KAISER PERMANENTE HARBOR MACARTHUR MOB 3/32" = 1'-0" 1/ 2 3 / 2 0 2 6 1 2 : 4 6 : 0 3 P M 01/23/2026 MG CL ES103 LEVEL 03 - ELECTRICAL PLAN - OVERALL 3401 South Harbor Boulevard, Santa Ana, CA 92704 10 0 % C D S E T 2441 3/32" = 1'-0"01 LEVEL 03 - ELECTRICAL - REMODEL PLAN - OVERALL 0 4'8'2' No. Revisions Date pl a n c h e c k s u b m i t t a l E J E J J 3R E 3R3R E J 3R 3 (E) 1 6 4 5 2 4 TE OLIRFFOAC LANRP E 23191 STA ER REGIST ED INA N REENIGE FO OISSE E AICLCERTL Exp. 06/30/26 MIRASOPHOCLISGEORGY IMEG RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAW ING AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG AND SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG. ©2024 IMEG CONSULTANTS CORP. REF. SCALE IN INCHES 0 1 2 3 222 S. HARBOR BOULEVARD SUITE 800 ANAHEIM, CA 92805 P: 714.490.5555 F: 714.490.5560 The FUTURE. Built Smarter www.imegcorp.com PROJECT #24007312.00 0 5' GRAPHIC SCALES: Issue Date 1/16" = 1'-0" 50' 1/8" = 1'-0"1/4" = 1'-0"1/2" = 1'-0"3/4" = 1'-0"1" = 1'-0"1-1/2" = 1'-0"3" = 1'-0" 0 5'25' 0 1'12' 0 1'6' 0 4' 0 3'1'0 2' 0 1' Chckd By Drwn By Scale Building ID: KP Proj. No. Permit No. Sheet SheetsOf Sheet Title Project Facility This document is the property of the Owner and is Project Architect Approval: Architect/Engineer Of Record: IF THIS SHEET IS NOT 30"x42" , IT IS A REDUCED PRINT - SCALE ACCORDINGLY National Facilities Services Post Office Box 12916 Oakland California 94604 not to be used without owner's written permission. Floor Lev: Section: HGW Proj. No. © A R C H I T E C T S h a n n a g a b r i e l w e l l s , a l l r i g h t s r e s e r v ed . A n y u s e w i t h o u t p e r m i s s i o n i s e x p r e s s l y p r o h i b i t ed . P l o t t e d CAP029271 1955 Bacon Street. San Diego, CA 92107 Office 619 523 8487 www.hgwarchitecture.com PROJECT #24007312.00 Revisions By Appr. KAISER HARBOR MACARTHUR MOB EXTERIOR SIGNAGE KAISER PERMANENTE HARBOR MACARTHUR MOB 1/4" = 1'-0" 1/ 2 3 / 2 0 2 6 1 2 : 4 6 : 0 4 P M 01/23/2026 MG CL ES122 LEVEL 02 - ENLARGED POWER PLAN 3401 South Harbor Boulevard, Santa Ana, CA 92704 10 0 % C D S E T 2441 0 4'8'2' 0 4'8'2' 0 4'8'2' 0 4'8'2' 1/4" = 1'-0"01 LEVEL 02 - ENLARGED - EAST SIGNAGE DEMO PLAN 1/4" = 1'-0"03 LEVEL 02 - ENLARGED - NORTH SIGNAGE DEMO PLAN 1/4" = 1'-0"02 LEVEL 02 - ENLARGED - EAST SIGNAGE REMODEL PLAN 1/4" = 1'-0"04 LEVEL 02 - ENLARGED - NORTH SIGNAGE REMODEL PLAN KEYNOTES: 1. EXTERIOR SIGNAGE TO BE REMOVED. DISCONNECT AND REMOVE EXISTING ELECTRICAL POWER CONNECTION AND ASSOCIATED WIRING BACK TO NEAREST JUNCTION BOX. EXISTING CIRCUIT AND CONDUIT TO REMAIN. 2. CONNECT NEW EXTERIOR SIGNAGE TO THE SAME CIRCUIT PREVIOUSLY FEEDING REMOVED EXTERIOR SIGNAGE, EXTEND CONDUIT AND WIRING AS REQUIRED. NEW EXTERIOR SIGNAGE SHALL BE CONTROL VIA EXISTING TIMECLOCK CONTROL LOCATED IN ELECTRICAL ROOM 1401. 3. EXTERIOR SIGNAGE TO BE REMOVED. DISCONNECT AND REMOVE EXISTING ELECTRICAL POWER CONNECTION, CONDUIT AND WIRING BACK TO NEAREST JUNCTION BOX. EXISTING CIRCUIT TO BE RE-USED TO FEED NEW EXTERIOR SIGNAGE AT NEW LOCATION. 4. PROVIDE AND INSTALL NEMA 3R SWITCH FOR EXTERIOR SIGNAGE. 5. POWER CONNECTION TO NEW EXTERIOR SIGNAGE. 6. CONNECT TO EXISTING EXTERIOR SIGNAGE CIRCUIT PREVIOUSLY FEEDING REMOVED EXTERIOR SIGNAGE. NEW EXTERIOR SIGNAGE SHALL BE CONTROL VIA EXISTING TIMECLOCK CONTROL LOCATED IN ELECTRICAL ROOM 1401. # No. Revisions Date pl a n c h e c k s u b m i t t a l E E J 3R 1 2 3 3PB2 -41 TE OLIRFFOAC LANRP E 23191 STA ER REGIST ED INA N REENIGE FO OISSE E AICLCERTL Exp. 06/30/26 MIRASOPHOCLISGEORGY IMEG RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAW ING AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG AND SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG. ©2024 IMEG CONSULTANTS CORP. REF. SCALE IN INCHES 0 1 2 3 222 S. HARBOR BOULEVARD SUITE 800 ANAHEIM, CA 92805 P: 714.490.5555 F: 714.490.5560 The FUTURE. Built Smarter www.imegcorp.com PROJECT #24007312.00 0 5' GRAPHIC SCALES: Issue Date 1/16" = 1'-0" 50' 1/8" = 1'-0"1/4" = 1'-0"1/2" = 1'-0"3/4" = 1'-0"1" = 1'-0"1-1/2" = 1'-0"3" = 1'-0" 0 5'25' 0 1'12' 0 1'6' 0 4' 0 3'1'0 2' 0 1' Chckd By Drwn By Scale Building ID: KP Proj. No. Permit No. Sheet SheetsOf Sheet Title Project Facility This document is the property of the Owner and is Project Architect Approval: Architect/Engineer Of Record: IF THIS SHEET IS NOT 30"x42" , IT IS A REDUCED PRINT - SCALE ACCORDINGLY National Facilities Services Post Office Box 12916 Oakland California 94604 not to be used without owner's written permission. Floor Lev: Section: HGW Proj. No. © A R C H I T E C T S h a n n a g a b r i e l w e l l s , a l l r i g h t s r e s e r v ed . A n y u s e w i t h o u t p e r m i s s i o n i s e x p r e s s l y p r o h i b i t ed . P l o t t e d CAP029271 1955 Bacon Street. San Diego, CA 92107 Office 619 523 8487 www.hgwarchitecture.com PROJECT #24007312.00 Revisions By Appr. KAISER HARBOR MACARTHUR MOB EXTERIOR SIGNAGE KAISER PERMANENTE HARBOR MACARTHUR MOB 1/4" = 1'-0" 1/ 2 3 / 2 0 2 6 1 2 : 4 6 : 0 5 P M 01/23/2026 MG CL ES123 LEVEL 03 - ENLARGED POWER PLAN 3401 South Harbor Boulevard, Santa Ana, CA 92704 10 0 % C D S E T 2441 0 4'8'2'0 4'8'2'1/4" = 1'-0"01 LEVEL 03 - ENLARGED - NORTHWEST SIGNAGE DEMO PLAN 1/4" = 1'-0"02 LEVEL 03 - ENLARGED - SOUTHWEST SIGNAGE REMODEL PLAN KEYNOTES: 1. EXTERIOR SIGNAGE TO BE REMOVED. DISCONNECT AND REMOVE EXISTING ELECTRICAL POWER CONNECTION WITH ASSOCIATED SWITCH, CONDUIT AND WIRING SWITCHES BACK TO SOURCE. 2. PROVIDE AND INSTALL NEMA 3R SWITCH FOR EXTERIOR SIGNAGE. 3. POWER CONNECTION TO NEW EXTERIOR SIGNAGE. 4. ROUTED VIA EXISTING TIMECLOCK CONTROL LOCATED IN ELECTRICAL ROOM 3320. # No. Revisions Date pl a n c h e c k s u b m i t t a l FIRST FLOOR SECOND FLOOR THIRD FLOOR DIST. BOARD 'DBB' -(E) 1200A, 480/277V, 3Ø, 4W, 42 KAIC TO MAIN SWBD 'MSA' -(E) 225A 3P XFMR '3PB' -(E) 150 KVA 480:120/208V '3PB1' -(E) 400A '3LB' - (E) '3PB2' - (E) 3"C., 4#4/0 2"C., 4#1 2-1/2"C., 3#4/0 4"C., 4#500 AREA OF WORK NOTES: 1. PROVIDE SUPPORTS @ 10'-0"oc MAX SPACING, AND 2'-0" MAX FROM ENDS OF CONDUIT RUN AND LOCATIONS WHERE CONDUIT CHANGES DIRECTION (EACH SIDE OF BEND). 2. 1-1/4" EMT CONDUIT WEIGHS 2.3 LBS PER FT OF RUN (INCLUDING WEIGHT OF CONDUCTORS INSIDE THE CONDUIT). THE WEIGHT IS 5 LBS PER FT OR LESS (2019 CBC, 1617A.I.18 ASCE 7, SECTION 13.1.4, EXEMPTION 3b), THEREFORE IT IS EXEMPT FROM SEISMIC DESIGN REQUIREMENTS (BRACING NOT REQUIRED). WITH HANGERS AT 10'-O" OC MAX, THE WEIGHT PER HANGER (SUPPORTING 1-1/4" EMT CONDUIT) IS 23 LBS, WHICH IS LESS THAN THE HANGER CAPACITY (70 LBS), AND IS LESS THAN 50 LBS PER HANGER (1617A.1.24 ASCE 7, SECTION 13.6.5, EXCEPTION 1b). CADDY K16 OR K20 INSTALL THE 0.145"Ø (0.300-INCH HEAD DRIVE PIN) WITH 1-1/2" EMBED INTO LOW FLUTE OF (E) 2-1/2" THK NWC (F'c=4,000 PSI) OVER 2" STEEL DECK PER ICC ESR-2024. STIFFY 102-02-01-3-02-XX" (1-1/2" PIN, 1/4" THREADED ROD) SINGLE CONDUIT LWC/NWC OVER 20GA. MIN., METAL DECK. CIRCUIT KEY NOTES:1. EXISTING LOAD TO REMAIN. 2. NEW LOAD ON EXISTING SPARE CIRCUIT BREAKER. *TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL. TOTAL ESTIMATED DEMAND AMPS:1.7 TOTAL CONNECTED AMPS:1.39 A TOTAL ESTIMATED DEMAND LOAD:0.625 kVA TOTAL CONNECTED LOAD:0.50 kVA Lighting 0.5 kVA 125.00% 0.625 kVA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND TOTALS* LOAD SUMMARY Total Amps:0.00 0.00 4.17 Total Load:0.00 kVA 0.00 kVA 0.50 kVA 2 41 EXTERIOR SIGNAGE - SOUTHWEST 20 1 12 12 12 0.5 -- -- -- -- 1 --SPACE 42 -- 39 0 0 -- -- -- 1 20 SPARE 40 ----37 EXISTING LOAD 20 2 -- -- --0 0 -- -- -- 1 20 SPARE 38 -- -- 35 ROOF BMS 20 1 -- -- -- 0 0 -- -- -- 1 20 SPARE 36 -- -- 33 SPARE 20 1 -- -- -- 0 0 -- -- -- 1 20 SPARE 34 -- -- 31 SPECIAL PROCEDURE 3335 20 1 -- -- -- 0 0 -- -- -- 1 20 MEDICATION REFRIG. RM 3321 32 -- -- 29 3220 TELCOM RM 20 1 -- -- -- 0 0 -- -- -- 1 20 3216 CHARTS 30 -- -- 27 3220 TELCOM RM 20 1 -- -- -- 0 0 -- -- -- 1 20 3216 CHARTS 28 -- -- 25 3220 TELCOM RM 20 1 -- -- -- 0 0 -- -- -- 1 20 3210, 3224, 3226, 3240 CORR.26 -- -- 23 3220 TELCOM RM 20 1 -- -- -- 0 0 -- -- -- 1 20 3208 WAITING 3236 CORR.24 -- -- 21 AAS CTRL PNL RM 3220,3238,3240, CORR.20 1 -- -- -- 0 0 -- -- -- 1 20 3207, 3208, 3209 EXAM 22 -- -- 19 3221 CLEAN UTILITY 20 1 -- -- -- 0 0 -- -- -- 1 20 3205 OFFICE 20 -- -- 17 3221 CLEAN UTILITY 20 1 -- -- -- 0 0 -- -- -- 1 20 3207, 3208, 3209 EXAM 18 -- -- 15 3221 CLEAN UTILITY - REFRIG.20 1 -- -- -- 0 0 -- -- -- 1 20 3205 OFFICE 16 -- -- 13 3221 CLEAN UTILITY - MED. FREEZER 20 1 -- -- -- 0 0 -- -- -- 1 20 3203 OFFICE, 3204 EXAM 14 -- -- 11 3221 CLEAN UTILITY - REFRIG.20 1 -- -- -- 0 0 -- -- -- 1 20 3203 OFFICE, 3202, 3204, EXAM 12 -- -- 9 3221 CLEAN UTILITY - ICE MAKER 20 1 -- -- -- 0 0 -- -- -- 1 20 3200, 3211, 3212 EXAM 10 -- -- 7 3222 SPEC. PROC.20 1 -- -- -- 0 0 -- -- -- 1 20 3200, 3211, 3212 EXAM 8 -- -- 5 3221 SPEC. PROC.20 1 -- -- -- 0 0 -- -- -- 1 20 3200, 3201, 3211, 3212 EXAM 6 -- -- 3 3220 SPEC. PROC.20 1 -- -- -- 0 0 -- -- -- 1 20 3210, 3213 NURSE STATION 4 -- -- 1 3219 SPEC. PROC. CLOCK 20 1 -- -- -- 0 0 -- -- -- 1 20 3210, 3213 NURSE STATION 2 -- K E Y CKT NO.LOAD DESCRIPTION OCPD AMPS P WIRE SIZE H N G A B C WIRE SIZE G N H OCPD P AMPS LOAD DESCRIPTION CKT NO. K E Y NOTES: ISC UNKNOWN 0.00 kA SCCR:Existing LOCATION:EQELC RM 3320 WIRE:4 FED FROM:'3PB1' - (E)GROUND BUS PHASE:3 ENCLOSURE:NEMA 1 SOLID NEUTRAL VOLTS:120/208 Wye MOUNTING:SURFACE SINGLE TUB MAIN:225 MLO PANEL '3PB2' - (E) TO ACCOMMODATE NEW LOAD ADDED EXISTING ELECTRICAL EQUIPMENT HAS SUFFICIENT CAPACITY TOTAL LOAD OF EXISTING PANEL 2.33 / 6.47 NET LOAD ADDITION (+) 0.50 / 1.39 TOTAL NEW LOAD ADDED (+) 0.50 / 1.39 EXTERIOR SIGNAGE (+) 0.50 / 1.39 NEW LOAD ADDED: EXISTING LOAD REMOVED (-) 0.00 / 0.00 EXISTING DEMAND LOAD X 125% 1.83 / 5.08 (BASED ON LOAD MONITORING) EXISTING DEMAND LOAD 1.47 / 4.07 KVA AMPS 100 AMPS 4 WIRE 3 Ø 10/8/2025 TO 10/15/2025 EXISTING RATINGS: 120/208 VOLT ON METERING OCCURING FROM ELECTRICAL BRANCH: NORMAL EXISTING DEMAND LOAD BASED BASED ON DEMAND LOAD LOAD SUMMARY FOR:'3PB2' - (E) ELECTRICAL LOAD CAPACITY VERIFICATION TE OLIRFFOAC LANRP E 23191 STA ER REGIST ED INA N REENIGE FO OISSE E AICLCERTL Exp. 06/30/26 MIRASOPHOCLISGEORGY IMEG RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAW ING AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG AND SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG. ©2024 IMEG CONSULTANTS CORP. REF. SCALE IN INCHES 0 1 2 3 222 S. HARBOR BOULEVARD SUITE 800 ANAHEIM, CA 92805 P: 714.490.5555 F: 714.490.5560 The FUTURE. Built Smarter www.imegcorp.com PROJECT #24007312.00 0 5' GRAPHIC SCALES: Issue Date 1/16" = 1'-0" 50' 1/8" = 1'-0"1/4" = 1'-0"1/2" = 1'-0"3/4" = 1'-0"1" = 1'-0"1-1/2" = 1'-0"3" = 1'-0" 0 5'25' 0 1'12' 0 1'6' 0 4' 0 3'1'0 2' 0 1' Chckd By Drwn By Scale Building ID: KP Proj. No. Permit No. Sheet SheetsOf Sheet Title Project Facility This document is the property of the Owner and is Project Architect Approval: Architect/Engineer Of Record: IF THIS SHEET IS NOT 30"x42" , IT IS A REDUCED PRINT - SCALE ACCORDINGLY National Facilities Services Post Office Box 12916 Oakland California 94604 not to be used without owner's written permission. Floor Lev: Section: HGW Proj. No. © A R C H I T E C T S h a n n a g a b r i e l w e l l s , a l l r i g h t s r e s e r v ed . A n y u s e w i t h o u t p e r m i s s i o n i s e x p r e s s l y p r o h i b i t ed . P l o t t e d CAP029271 1955 Bacon Street. San Diego, CA 92107 Office 619 523 8487 www.hgwarchitecture.com PROJECT #24007312.00 Revisions By Appr. KAISER HARBOR MACARTHUR MOB EXTERIOR SIGNAGE KAISER PERMANENTE HARBOR MACARTHUR MOB 12" = 1'-0" 1/ 2 3 / 2 0 2 6 1 2 : 4 6 : 0 5 P M 01/23/2026 MG CL ES400 PARTIAL SINGLE LINE DIAGRAM, PANEL SCHEDULES, LOAD CALCULATIONS, & DETAILS 3401 South Harbor Boulevard, Santa Ana, CA 92704 10 0 % C D S E T 2441 NTS01PARTIAL SINGLE LINE DIAGRAMS - SIGNAGE PKG NTS023/4 AND 1 INCH EMT - CONDUIT SUPPORT DETAIL - SIGNAGE PKG No. Revisions Date 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 pl a n c h e c k s u b m i t t a l 0 5' GRAPHIC SCALES: Issue Date 1/16" = 1'-0" 50' 1/8" = 1'-0" 1/4" = 1'-0" 1/2" = 1'-0" 3/4" = 1'-0" 1" = 1'-0" 1-1/2" = 1'-0" 3" = 1'-0" 0 5' 25'0 1' 12'0 1' 6'0 4'0 3'1'0 2'0 1' Chckd By Drwn By Scale Building ID: KP Proj. No. Permit No. Sheet SheetsOf Sheet Title Project Facility This document is the property of the Owner and is Project Architect Approval: Architect/Engineer Of Record: IF THIS SHEET IS NOT 30"x42" , IT IS A REDUCED PRINT - SCALE ACCORDINGLY National Facilities Services Post Office Box 12916 Oakland California 94604 not to be used without owner's written permission. Floor Lev: Section: Revisions By Appr. HGW Proj. No. © H G W A r c h i t e c t u r e , a l l r i g h t s r e s e r v e d . A n y u s e w i t ho u t p e r m i s s i o n i s e x p r e s s l y p r o h i b i t e d . P l o t t e d 1955 Bacon Street. San Diego, CA 92107 Office 619 523 8487 www.hgwarchitecture.com KAISER PERMANENTE BUILDINGS ON BRAND 3/ 1 8 / 2 0 2 6 1 1 : 0 8 : 1 8 A M 03/17/2026 Checker Author CAP030942 SG200 EXTERIOR SIGNAGE - PAGES 1 THRU 4 3401 South Harbor Boulevard, Santa Ana, CA 92704 pl a n c h e c k r e s u b m i t t a l 2441 EXTERIOR SIGNAGE - HARBOR-MAC ARTHUR No. Revisions Date 1 SD 06/05/2025 2 DD 07/03/2025 3 90% CD 08/15/2025 12 Plan Check Resubmittal 02/25/2026 0 5' GRAPHIC SCALES: Issue Date 1/16" = 1'-0" 50' 1/8" = 1'-0" 1/4" = 1'-0" 1/2" = 1'-0" 3/4" = 1'-0" 1" = 1'-0" 1-1/2" = 1'-0" 3" = 1'-0" 0 5' 25'0 1' 12'0 1' 6'0 4'0 3'1'0 2'0 1' Chckd By Drwn By Scale Building ID: KP Proj. No. Permit No. Sheet SheetsOf Sheet Title Project Facility This document is the property of the Owner and is Project Architect Approval: Architect/Engineer Of Record: IF THIS SHEET IS NOT 30"x42" , IT IS A REDUCED PRINT - SCALE ACCORDINGLY National Facilities Services Post Office Box 12916 Oakland California 94604 not to be used without owner's written permission. Floor Lev: Section: Revisions By Appr. HGW Proj. No. © H G W A r c h i t e c t u r e , a l l r i g h t s r e s e r v e d . A n y u s e w i t ho u t p e r m i s s i o n i s e x p r e s s l y p r o h i b i t e d . P l o t t e d 1955 Bacon Street. San Diego, CA 92107 Office 619 523 8487 www.hgwarchitecture.com KAISER PERMANENTE BUILDINGS ON BRAND 3/ 1 8 / 2 0 2 6 1 1 : 0 8 : 1 8 A M 03/17/2026 Checker Author CAP030942 SG201 EXTERIOR SIGNAGE - PAGES 5 THRU 8 3401 South Harbor Boulevard, Santa Ana, CA 92704 pl a n c h e c k r e s u b m i t t a l 2441 EXTERIOR SIGNAGE - HARBOR-MAC ARTHUR No. Revisions Date 1 SD 06/05/2025 2 DD 07/03/2025 3 90% CD 08/15/2025 12 Plan Check Resubmittal 02/25/2026 0 5' GRAPHIC SCALES: Issue Date 1/16" = 1'-0" 50' 1/8" = 1'-0" 1/4" = 1'-0" 1/2" = 1'-0" 3/4" = 1'-0" 1" = 1'-0" 1-1/2" = 1'-0" 3" = 1'-0" 0 5' 25'0 1' 12'0 1' 6'0 4'0 3'1'0 2'0 1' Chckd By Drwn By Scale Building ID: KP Proj. No. Permit No. Sheet SheetsOf Sheet Title Project Facility This document is the property of the Owner and is Project Architect Approval: Architect/Engineer Of Record: IF THIS SHEET IS NOT 30"x42" , IT IS A REDUCED PRINT - SCALE ACCORDINGLY National Facilities Services Post Office Box 12916 Oakland California 94604 not to be used without owner's written permission. Floor Lev: Section: Revisions By Appr. HGW Proj. No. © H G W A r c h i t e c t u r e , a l l r i g h t s r e s e r v e d . A n y u s e w i t ho u t p e r m i s s i o n i s e x p r e s s l y p r o h i b i t e d . P l o t t e d 1955 Bacon Street. San Diego, CA 92107 Office 619 523 8487 www.hgwarchitecture.com KAISER PERMANENTE BUILDINGS ON BRAND 3/ 1 8 / 2 0 2 6 1 1 : 0 8 : 2 0 A M 03/17/2026 Checker Author CAP030942 SG202 EXTERIOR SIGNAGE - PAGES 9 THRU 12 3401 South Harbor Boulevard, Santa Ana, CA 92704 pl a n c h e c k r e s u b m i t t a l 2441 EXTERIOR SIGNAGE - HARBOR-MAC ARTHUR No. Revisions Date 1 SD 06/05/2025 2 DD 07/03/2025 3 90% CD 08/15/2025 12 Plan Check Resubmittal 02/25/2026 0 5' GRAPHIC SCALES: Issue Date 1/16" = 1'-0" 50' 1/8" = 1'-0" 1/4" = 1'-0" 1/2" = 1'-0" 3/4" = 1'-0" 1" = 1'-0" 1-1/2" = 1'-0" 3" = 1'-0" 0 5' 25'0 1' 12'0 1' 6'0 4'0 3'1'0 2'0 1' Chckd By Drwn By Scale Building ID: KP Proj. No. Permit No. Sheet SheetsOf Sheet Title Project Facility This document is the property of the Owner and is Project Architect Approval: Architect/Engineer Of Record: IF THIS SHEET IS NOT 30"x42" , IT IS A REDUCED PRINT - SCALE ACCORDINGLY National Facilities Services Post Office Box 12916 Oakland California 94604 not to be used without owner's written permission. Floor Lev: Section: Revisions By Appr. HGW Proj. No. © H G W A r c h i t e c t u r e , a l l r i g h t s r e s e r v e d . A n y u s e w i t ho u t p e r m i s s i o n i s e x p r e s s l y p r o h i b i t e d . P l o t t e d 1955 Bacon Street. San Diego, CA 92107 Office 619 523 8487 www.hgwarchitecture.com KAISER PERMANENTE BUILDINGS ON BRAND 3/ 1 8 / 2 0 2 6 1 1 : 0 8 : 2 1 A M 03/17/2026 Checker Author CAP030942 SG203 EXTERIOR SIGNAGE - PAGE 13 3401 South Harbor Boulevard, Santa Ana, CA 92704 pl a n c h e c k r e s u b m i t t a l 2441 EXTERIOR SIGNAGE - HARBOR-MAC ARTHUR No. Revisions Date 1 SD 06/05/2025 2 DD 07/03/2025 3 90% CD 08/15/2025 12 Plan Check Resubmittal 02/25/2026 YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs