Loading...
HomeMy WebLinkAboutHOLD-941 W McFadden Ave & Unit #2 - REV 1 - PlanDR A W I N G D A T E : Ma r 5 , 2 0 2 6 ( 3 : 1 4 P M ) SHEET #: JO B A D D R E S S : 94 1 W M C F A D D E N A V E . / 9 4 1 W MC F A D D E N A V E . U N I T 2 SA N T A A N A , C A 9 2 7 0 7 NO . RE V I S I O N : DA T E : BY : EN G I N E E R : DE S I G N E D B Y : DR A W N B Y : RE V I E W E D B Y : PE R M I T N O . -- C. S . A. C . C. S . DE S I G N G R O U P : ENGINEER OF RECORD: PR O J E C T D E S C R I P T I O N HO M E RE M O D E L / ( N ) AD U STA N D L E Y S T R U C T U R A L D E S I G N CIV I L - S T R U C T U R A L E N G I N E E R S Located at: 17940 Ventura Blvd. Encino, CA 91316 Call: (213) 373-4513 A. C . PR O J E C T I N F O . 00.A1 LEGAL DESCRIPTION: 941 W. McFADDEN AVE./941 W. McFADDEN AVE. UNIT 2 SANTA ANA, CA 92707 ASSESSOR PARCEL NO.010-263-30 TRACT LOT NO. BLOCK BASELINE HILLSIDE ORDINANCE TYPE OF CONSTRUCTION OCCUPANCY NO. OF STORIES 471 PARKING 16 N/A NO TYPE-VB RESIDENTIAL: R3 1 2-CAR GARAGE SHEET INDEX 00-A1 COVER PAGE/GENERAL NOTES 01-A2 01-A3 02-S1 02-S2 SITE PLAN MAIN HOUSE FLOOR PLANS FOUNDATION PLAN VICINITY MAP SCOPE OF WORK STRUCTURAL NOTES HOME REMODEL INCLUDES: PC#102123157 - PRIMARY RESIDENCE -CONVERT EXISTING LAUNDRY ROOM TO MASTER BATHROOM -RELOCATE WATER HEATER TO EXTERIOR -REPLACE DOOR WITH NEW WINDOW IN MASTER BATHROOM -INSTALL NEW FENCE AT FRONT YARD PC#102123158 - DETACHED ADU -CONVERT EXISTING 284 SQ. FT. GARAGE TO ADU -CONSTRUCT 338 SQ. FT. ADU ADDITION PROJECT NAME: 941 W MCFADDEN AVE. SANTA ANA, CA 92707 NOT TO SCALE PROJECT TEAM OWNER CONTRACTOR DESIGNER SOILS/SURVEYOR TITLE-24 HOME REMODEL/(N) ADU CODES -2022 CALIFORNIA BUILDING CODE (CBC) -2022 CALIFORNIA RESIDENTIAL CODE (CRC) -2022 CALIFORNIA MECHANICAL CODE (CMC) -2022 CALIFORNIA ELECTRICAL CODE (CEC) -2022 CALIFORNIA PLUMBING CODE (CPC) -2022 CALIFORNIA ENERGY CODE -2022 CALIFORNIA GREEN CODE CRAIG STANDLEY (LIC.. #87675) 17940 VENTURA BLVD., ENCINO, CA 91316 P: 213-373-4513 E: CRAIG@STANDLEYSTRUCTURAL.COM SQ. FOOTAGE INFO. BUILDING 1 SIZE 6277 SQ. FT. .LOT SIZE 932 SQ. FT. LOT COVERAGE 02-S3 CEILING FRAMING PLAN RFA 1592/6277 = 25.36% FIRE SPRINKLERS?NO (E) GARAGE INTO ADU 307 SQ. FT. (N) ADDITION TO ADU 353 SQ. FT. 1592/6277 = 25.36% 01-A3.1 ADU FLOOR PLANS 01-A4 ADU ELEVATIONS 02-S4 ROOF FRAMING PLAN *NO DEFERRED SUBMITTAL* Note on plans: Mechanical, electrical, and plumbing (MEP) systems are not included in this plan review or approval. All MEP work is subject to field inspection by the Building Division. 03-A6 T24-MAIN HOME 03-A6.1 T24-ADU NOTE: TOTAL SQ. FT. NOT INCLUDING EXTERIOR WALLS EQUALS 622 SQ. FT. INCLUDING THE EXTERIOR WALLS THE TOTAL SQ. FT. IS 661 SQ. FT. PL PL PL PL PL PL PLPL PL PL PL PL PL PL PL PL MCFADDEN AVE. 50.00' 12 5 . 5 4 ' W/H PL PL PL PL PL PL PLPL PL PL PL PL PL PL PL PL MCFADDEN AVE. 50.00' 12 5 . 5 4 ' W/H 1' - 3 " 1' - 3 " 3'-1" 5'-0" 8' - 7 " (N) STACKABLE W/D (N) 45"x55" S.H. 15'-10" 50.00' 12 5 . 5 4 ' 50.00' 12 5 . 5 4 ' 26 ' - 9 " 9'-6" 7'-3" 67 ' - 9 " 28 ' - 4 " 1'-1" 19 ' - 3 " 30'-9" 26 ' - 9 " 9'-6" 7'-3" 67 ' - 9 " 5' - 2 " 19 ' - 3 " 30'-9" 4'-0" 4'-0" (E) HARDSCAPE (E) LANDSCAPE (E) HARDSCAPE (E) HARDSCAPE (E) LANDSCAPE (E) HARDSCAPE (E) LANDSCAPE (E) HARDSCAPE (E) LANDSCAPE 27'-9" 19 ' - 3 " (E) HARDSCAPE TO BE DEMOE'D TO ACHIEVE REQUIRED 65% LANDSCAPE AT FRONT YARD 14'-7" 22 ' - 1 1 " 5'-0"5'-0" 8' - 0 " 7' - 9 " 31 ' - 3 " (N ) ST A C K A B L E W/ D (N) TANK LESS WATER HEATER TO BE ENCLOSED IN AN ENCLOSURE THAT MATCHES EXTERIOR STRUCTURE (N) MINI SPLIT 3' - 0 " 2'-0"12'-3" 11 ' - 1 " (N) LANDSCAPE (N) 1 GALLON SHRUB (N) 5 GALLON SHRUB (N) 24" BOX CANOPY TREE 2% 2% 2% 2% DR A W I N G D A T E : Ma r 5 , 2 0 2 6 ( 3 : 1 5 P M ) SHEET #: JO B A D D R E S S : 94 1 W M C F A D D E N A V E . / 9 4 1 W MC F A D D E N A V E . U N I T 2 SA N T A A N A , C A 9 2 7 0 7 NO . RE V I S I O N : DA T E : BY : EN G I N E E R : DE S I G N E D B Y : DR A W N B Y : RE V I E W E D B Y : PE R M I T N O . -- C. S . A. C . C. S . DE S I G N G R O U P : ENGINEER OF RECORD: PR O J E C T D E S C R I P T I O N HO M E RE M O D E L / ( N ) AD U STA N D L E Y S T R U C T U R A L D E S I G N CIV I L - S T R U C T U R A L E N G I N E E R S Located at: 17940 Ventura Blvd. Encino, CA 91316 Call: (213) 373-4513 A. C . SI T E P L A N 01-A2 GENERAL NOTES: 1.SMOKE DETECTORS SHALL BE PROVIDED IN EACH SLEEPING ROOM, ON THE CEILING OR WALL IMMEDIATELY OUTSIDE OF EACH SLEEPING ROOM, AND ON EACH STORY AND BASEMENT FOR DWELLINGS WITH MORE THAN ONE STORY (907.2.11.2, R314.3) 2. THE POWER SOURCE FOR SMOKE DETECTORS SHALL BE AS FOLLOWS: A. IN NEW CONSTRUCTION SMOKE DETECTORS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING AND SHALL BE EQUIPPED WITH A BATTERY BACKUP B. IN EXISTING SFD, SMOKE DETECTORS MAY BE BATTERY OPERATED C. CARBON MONOXIDE ALARM IS REQUIRED PER SEC. 420.4 & R315 3.THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PILL-BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. 4.AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. (PER ORDINANCE 171, 874) (SEPARATE PLUMBING PERMIT IS REQUIRED). 5.PROVIDE ULTRA FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. 6.AN APPROVED CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN DWELLING UNITS AND IN SLEEPING UNITS WITHIN WHICH FUEL-BURNING APPLICATIONS ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES. CARBON MONOXIDE DETECTORS SHALL BE PROVIDED OUTSIDE OF EACH SEPARATE DWELLING UNIT SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM(S0 AND ON EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS. (R315) 7.ARCHITECTURAL PAINTS AND COATINGS, ADHESIVES, CAULKS AND SEALANTS SHALL COMPLY WITH THE VOLATILE ORGANIC COMPOUND (VOC) LIMITS LISTED IN TABLES 4.504.1-4.504.3 8.THE APPROVAL OF PLANS AND SPECIFICATIONS DOES NOT PERMIT THE VIOLATION OF ANY SECTION OF THE BUILDING CODE OR OTHER CITY ORDINANCE OR STATE LAWS. 9.WHERE A PERMIT IS REQUIRED FOR ALTERATIONS, REPAIRS, OR ADDITIONS EXCEEDING ONE THOUSAND DOLLARS ($1,000), EXISTING DWELLING OR SLEEPING UNITS THAT HAVE ATTACHED GARAGES OR FUEL-BURNING APPLIANCES SHALL BE PROVIDED WITH A CARBON MONOXIDE DETECTOR IN ACCORDANCE WITH SECTION R315.1. CARBON MONOXIDE DETECTORS SHALL ONLY BE REQUIRED IN THE SPECIFIC DWELLING UNIT OR SLEEPING UNIT FOR WHICH THE PERMIT WAS OBTAINED. (R315.2) 10.EFFECTIVE JAN. 1, 201, SB 407 REQUIRES REPLACEMENT OF ALL NONCOMPLIANT PLUMBING FIXTURES IN PROPERTIES BUILT ON OR BEFORE JAN. 1, 2994 WITH WATER CONSERVING PLUMBING FIXTURES 11.SMOKE DETECTORS SHALL BE PROVIDED FOR ALL DWELLING UNITS INTENDED FOR HUMAN OCCUPANCY, UPON THE OWNER'S APPLICATION FOR A PERMIT FOR ALTERATIONS, REPAIRS, OR ADDITIONS, EXCEEDING ONE THOUSAND DOLLARS ($1,000) (R314.6.2) 12.AN OPERATION AND MAINTEANCE MANUAL INCLUDING AT A MINIMUM, THE ITEMS LISTED IN SECTION 4.410.1 SHALL BE COMPLETED AND PLACED IN THE BUILDING AT THE TIME OF FINAL INSPECTION 13.WATER HEATER MUST BE STRAPPED TO WALL. 15.UNIT SKYLIGHTS SHALL BE LABELED BY A LA CITY APPROVED LABELING AGENCY. SUCH LABEL SHALL STATE THE APPROVED LABELING AGENCY NAME, PRODUCT DESIGNATION AND PERFORMANCE GRADE RATING (RESEARCH REPORT NOT REQUIRED) 16.FOR EXISTING POOL ON SITE, PROVIDE AN ALARM FOR DOORS TO THE DWELLING THAT FORM A PART OF THE POOL ENCLOSURE. THE ALARM SHALL SOUND CONTINUOUSLY FOR A MIN. OF 30 SECONDS WHEN THE DOOR IS OPENED. IT SHALL AUTOMATICALLY RESET AND BE EQUIPPED WITH WITH A MANUAL MEANS TO DEACTIVATE (FOR 15 SECS. MAX.) FOR A SINGLE OPENING. THE DEACTIVATION SWITCH SHALL BE AT LEAST 54" ABOVE THE FLOOR 17.FOR EXISTING POOL ON SITE, PROVIDE ANTI-ENTRAPMENT COVER MEETING THE CURRENT ASTM OR SME FOR THE SUCTION OUTLETS OF THE SWIMMING POOL, TODDLER POOL, AND SPA FOR SINGLE FAMILY DWELLINGS. 18.AUTOMATIC GARAGE DOOR OPENERS IF PROVIDED SHALL BE LISTED IN ACCORDANCE WITH UL 325 19.EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH NATURAL LIGHT BY MEANS OF EXTERIOR GLAZED OPENINGS IN ACCORDANCE WITH SECTION R303.1 OR SHALL BE PROVIDED WITH ARTIFICIAL LIGHT THAT IS ADEQUATE TO PROVIDE AN AVERAGE ILLUMINATION OF 6 FOOT CANDLES OVER THE AREA OF THE ROOM AT HEIGHT OF 30 INCHES ABOVE FLOOR LEVEL 20.A COPY OF THE RESEARCH REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE AVAILABLE AT THE JOB SITE 21.CONTRACTORS RESPONSIBLE FOR THE CONSTRUCTION OF A WIND OR SEISMIC FORCE RESISTING SYSTEM/COMPONENT LISTED IN THE "STATEMENT OF SPECIAL INSPECTION" SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE LADBS INSPECTORS AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON SUCH SYSTEM OR COMPONENT PER SEC 1706.1 22.WHERE A PERMIT IS REQUIRED FOR ALTERATIONS, REPAIRS, OR ADDITIONS EXCEEDING ONE THOUSAND DOLLARS ($1,000), EXISTING DWELLING OR SLEEPING UNITS THAT HAVE ATTACHED GARAGES OR FUEL-BURNING APPLIANCES SHALL BE PROVIDED WITH A CARBON MONOXIDE DETECTOR IN ACCORDANCE WITH SECTION R315.1. CARBON MONOXIDE DETECTORS SHALL ONLY BE REQUIRED IN THE SPECIFIC DWELLING UNIT OR SLEEPING UNIT FOR WHICH THE PERMIT WAS OBTAINED. (R315.2) 23.SMOKE DETECTORS SHALL BE PROVIDED FOR ALL DWELLING UNITS INTENDED FOR HUMAN OCCUPANCY, UPON THE OWNER'S APPLICATION FOR A PERMIT FOR ALTERATIONS, REPAIRS, OR ADDITIONS, EXCEEDING ONE THOUSAND DOLLARS ($1,000) (R314.6.2) SITE PLAN (PROPOSED) SHOWING AREA OF WORK SCALE: 1/8"=1'-0" SITE EXISTING (PROPOSED) SHOWING AREA OF WORK SCALE: 1/8"=1'-0" WATER HEATER TO BE STRAPPED USING THE RHEEM SP13345 EARTHQUAKE STRAP TWO STRAPS ARE REQUIRED, ONE IN THE UPPER THIRD AND ONE IN THE LOWER THIRD (ATLEAST 4" ABOVE THE CONTROLS) W/H W/H 1' - 3 " 1' - 3 " 3'-1" 5'-0" 8' - 7 " (N) STACKABLE W/D (N) 45"x55" S.H. 20'-9" 8' - 0 " 12 ' - 6 " 1' - 4 " 6' - 8 " MAX HT. CLG' TOP OF FINISH FLOOR (N) WATER HEATER WITH STUCCO MATERIAL 21'-4"14'-8" DRIVEWAYWALK WAY 8'-0"12'-0"13'-4" 3' - 0 " 11'-4" 22 ' - 4 " 23 ' - 0 " 33'-3" 11'-10"5'-0"15'-1" 10 ' - 0 " 2' - 0 " 5' - 0 " 2' - 0 " 10 ' - 0 " 11'-10" 10 ' - 0 " 12'-6" 31 ' - 0 " 20'-5" 3' - 0 " (N) CMU BLOCK TO MATCH EXISTING STUCCO DR A W I N G D A T E : Ma r 5 , 2 0 2 6 ( 3 : 1 5 P M ) SHEET #: JO B A D D R E S S : 94 1 W M C F A D D E N A V E . / 9 4 1 W MC F A D D E N A V E . U N I T 2 SA N T A A N A , C A 9 2 7 0 7 NO . RE V I S I O N : DA T E : BY : EN G I N E E R : DE S I G N E D B Y : DR A W N B Y : RE V I E W E D B Y : PE R M I T N O . -- C. S . A. C . C. S . DE S I G N G R O U P : ENGINEER OF RECORD: PR O J E C T D E S C R I P T I O N HO M E RE M O D E L / ( N ) AD U STA N D L E Y S T R U C T U R A L D E S I G N CIV I L - S T R U C T U R A L E N G I N E E R S Located at: 17940 Ventura Blvd. Encino, CA 91316 Call: (213) 373-4513 A. C . PR O P O S E D F L O O R P L A N 01-A3 LEGEND: EXISTING WALLS: NEW WALLS: WALLS TO REMOVE: SMOKE DETECTOR: (WIRED W/ BATTERY BACK UP) CARBON MONOXIDE ALARM: (HARD-WIRED W/ BATTERY BACKUP) BATHROOM FAN (MIN. 50 CFM) (DUCTED TO OUTSIDE OF BUILDING)(ENERGY STAR W/ HUMIDISTAT) S C F SWITCH 125 VOLT GROUND FAULT OUTLET CEILING OR WALL LIGHT S KITCHEN EXHAUST SYSTEM VENTED TO OUTSIDE (MIN. 100 CFM)K 3 WAY SWITCH S 3 G.F.I. DIMMER SWITCH 220 VOLT OUTLET 220V ARC FAULT INTERRUPTION CIRCUIT AFIC ELEC. MAIN/SUB PANEL GARAGE DOOR OPENER G.D.O. GREEN NOTES 1.ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES,, CONDUITS, OR OTHER OPENINGS IN THE BUILDINGS ENVELOPE AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY, OR METAL PLATES. 2.FOR ALL NEW EQUIPMENT, AN OPERATION AND MAINTENANCE MANUAL INCLUDING, AT A MINIMUM THE ITEMS LISTED IN SECTION 4.410.1, SHALL BE COMPLETED AND PLACED IN THE BUILDING AT THE TIME OF FINAL INSPECTION 3.ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, OR SHEET METAL UNTIL THE FINAL SARTUP OF THE HEATING, COOLING AND VENT. EQUIPMENT 4.THE VOC CONTENT VERIFICATION CHECKLIST SHALL BE COMPLETED AND VERIFIED PRIOR TO FINAL INSPECTION APPROVAL. THE MANUFACTURERS SPECIFICATIONS SHOWING VOC CONTENT FOR ALL APPLICABLE PRODUCTS SHALL BE READILY AVAILABLE AT THE JOB SITE AND BE PROVIDED TO THE FIELD INSPECTOR FOR VERIFICATION 5.ALL NEW CARPET AND CARPET CUSHIONS INSTALLE DIN THE BUILDING INTERIOR SHALL MEET THE TESTING PRODUCT REQUIREMENTS OF ONE OF THE FOLLOWING 1. CARPET AND RUG INSTITUTES GREEN LABEL PLUS PROGRAM 2. CALIFORNIA DEPT. OF PUBLIC HEALTH'S SPECIFICATIONS 3. NSF/ANSI 140 AT THE GOLD LEVEL 4. SCIENTIFIC CERTIFICATIONS SYSTEMS INDOOR ADVANTAGE 6.80% OF THE TOTAL AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH ONE OR MORE OF THE FOLLOWING 1. VOC EMISSION LIMITS DEFINED IN THE CHPS HIGH PERFORMANCE PRODUCTS DATABASE 2. CERTIFIED UNDER UL GREENGUARD GOLD 3. CERTIFICATION UNDER THE RESILIENT FLOOR COVERING INSTITUTE 4. MEET THE CALIFORNIA DEPT. OF PUBLIC HEALTH'S SPECIFICATIONS 7.THE HEATING AND AIR CONDITIONING SYSTEMS SHALL BE SIZED AND DESIGNED USING ANSI/ACCA MANUAL J-2004, ANSI/ACCA 29-D-2009 OR ASHRAE HANDBOOKS AND HAVE THEIR EQUIPMENT SELECTED IUN ACCORDANCE WITH ANSI/ACCA 36-S MANUAL S-2004 8.WHEN A SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, THE COMBINED FLOW RATE OF ALL THE SHOWERHEADS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 2.0 GALLONS PER MINUTE AT 80psi, OR THE SHALL BE DESIGNED TO ONLY ALLOW ONE SHOWERHEAD TO BE IN OPERATION AT A TIME 9.THE FLOW RATES FOR ALL PLUMBING FIXTURES SHALL COMPLY WITH THE MAXIMUM FLOW RATES IN SECTION 4.303.1 10.THE HOT WATER SYSTEM SHALL NOT ALLOW MORE THAN 0.6 GALLONS OF WATER TO BE DELIVERED TO ANY FIXTURES BEFORE HOT WATER ARRIVES OR SHALL COMPLY WITH EITHER LOS ANGELES PLUMBING CODE SECTION 610.4.1.2 OR 610.4.1.3 EXISTING 1ST FLOOR PLAN SHOWING AREA OF WORKSCALE: 1/4"=1'-0" #SIZE(WXH)DESCRIPTION REMARKS WINDOW SCHEDULE #SIZE (WXH)DESCRIPTION REMARKS DOOR SCHEDULE EXISTING EXISTING TO REMAIN(E) MECHANICAL 1.GROUND FAULT CIRCUIT-INTERRUPTION (GFCI) FOR PERSONNEL SHALL BE RPOVIDED AND INSTALLED IN READILY ACCESSIBLE AREA 2.ARC-FAULT CIRCUIT INTERRUPTION SHALL BE INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT 3.TAMPER-RESISTANT RECEPTACLES SHALL BE INSTALLED IN ALL AREAS SPECIFIED IN 210.52, ALL NONLOCKING TYPE 12-VOLT; 15- AND 20-AMPERE RECEPTACLES SHALL BE LISTED TAMPER-RESISTANT PLUMBING 1.PLUMBING FIXTURES ARE REQUIRED TO BE CONNECTED TO A SANITARY SEWER OR TO AN APPROVED SEWAGE DISPOSAL SYSTEM 2.KITCHEN SINKS, LAVATORIES, BATHTUBS, SHOWERS, BIDETS, LAUNDRY TUBS AND WASHING MACHINE OUTLETS SHALL BE PROVIDED WITH HOT AND COLD WATER AND CONNECTED TO AN APPROVED WATER SUPPLY 3.BATHTUB AND SHOWER FLOORS, WALLS ABOVE BATHTUBS WITH A SHOWERHEAD, AND SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR 4.PROVIDE ULTRA FLUSH WATER CLOSET FOR ALL NEW CONSTRUCTION, EXISTING SHOWERHEADS AND TOILETS MUST BE ADOPTED FOR LOW WATER CONSUMPTION 5.MECHANICAL, ELECTRICAL, AND PLUMBING PLANS ARE NOT REVIEWED AND ARE SUBJECT TO FIELD INSPECTION 6.THE FLOW RATES FOR ALL NEW PLUMBING FIXTURES SHALL COMPLY WITH THE MAXIMUM FLOW RATES SPECIFIED IN SECTION 4.303.1 PROPOSED 1ST FLOOR PLAN SHOWING AREA OF WORKSCALE: 1/4"=1'-0" EXISTING EXISTING TO REMAIN(E) 1 2'-8"x6'-8"SINGLE HUNG1 3'-9"x4'-7"SINGLE HINGED 2 3'-0"x3'-0"SINGLE HINGED2 3'-0"x6'-8"SINGLE HUNG 1 2 1 2 1 F SOUTH PROPOSED ELEVATION VIEW SHOWING AREA OF WORK SCALE: 1/4"=1'-0" SOUTH PROPOSED ELEVATION VIEW OF FENCE SHOWING AREA OF WORK SCALE: 1/4"=1'-0" SLOPE AT EXTERIOR LANDINGS SHALL NOT EXCEED 1 4 INCH PER FOOT (2%) (R311.3) ` All residential front yard fences shall conform to section 41-610 of the Municipal Code. The following design examples and site plan are to be used for reference when preparing submittal plans for a front yard fence permit. 4-inch Max Width 4-inch Min Spacing Example of Wood Picket/Wrought Iron Fence Design Front Yard St r e e t Grade Decorative Element *Please refer to Sight Triangle Handout 8- f o o t M i n (m e a s u r e d f r o m c e n t e r ) Front Yard 25’ 25’ Sight Triangle on corners (25’ x 25’) House Grass Street Pr o p e r t y L i n e Pr o p e r t y L i n e Property Line Front Yard 8-foot Minimum Separation Between Pilasters (measured from center) Pr o p e r t y L i n e Pr o p e r t y L i n e Property Line Fr o n t Y a r d Mi n 2 0 - f e e t o r Pr e v a i l i n g Se t b a c k 4-foot Max Entry 8-foot Min (measured from center) Location of Pilasters Garage House Grass Driveway and/or Walkway Example of Masonry Fence Design with Pilasters 18-inch Max Height for Solid Materials 16-inch Max Width 4-inch Minimum Spacing (10-inches on Arterial streets) Prohibited 36-inch Max Height for Non-Arterial Street or 48-inch Max Height for Arterial Street Planning and Building Agency Planning Division 20 Civic Center Plaza P.O. Box 1988 (M-20) Santa Ana, CA 92702 (714) 647-5804 www.santa-ana.org RESIDENTIAL FRONT YARD FENCES Example of Residential Site Plan- Corner Lot Example of Residential Site Plan- Non Corner Lot 14'-7" 22 ' - 1 1 " 5'-0"5'-0" 8' - 0 " 7' - 9 " 31 ' - 3 " (N ) ST A C K A B L E W/ D(N) TANK LESS WATER HEATER (N) MINI SPLIT CONDENSER LOCATED IN ATTIC 3' - 0 " 2'-0"12'-3" 11 ' - 1 " 3' - 0 " 3'-0" (N) 3X3 LANDING 1 -1/2" 42 ' - 8 " 14'-7" WALL FINISH TO BE NONABSORBENT AND A MINIMUM 6 FEET OFF FLOOR/GLASS TO BE TEMPERED 43 ' - 4 " 15'-3" DR A W I N G D A T E : Ma r 5 , 2 0 2 6 ( 3 : 1 5 P M ) SHEET #: JO B A D D R E S S : 94 1 W M C F A D D E N A V E . / 9 4 1 W MC F A D D E N A V E . U N I T 2 SA N T A A N A , C A 9 2 7 0 7 NO . RE V I S I O N : DA T E : BY : EN G I N E E R : DE S I G N E D B Y : DR A W N B Y : RE V I E W E D B Y : PE R M I T N O . -- C. S . A. C . C. S . DE S I G N G R O U P : ENGINEER OF RECORD: PR O J E C T D E S C R I P T I O N HO M E RE M O D E L / ( N ) AD U STA N D L E Y S T R U C T U R A L D E S I G N CIV I L - S T R U C T U R A L E N G I N E E R S Located at: 17940 Ventura Blvd. Encino, CA 91316 Call: (213) 373-4513 A. C . PR O P O S E D F L O O R P L A N 01-A3.1 LEGEND: EXISTING WALLS: NEW WALLS: WALLS TO REMOVE: SMOKE DETECTOR: (WIRED W/ BATTERY BACK UP INTERCONNECTED) CARBON MONOXIDE ALARM: (HARD-WIRED W/ BATTERY BACKUP) BATHROOM FAN (MIN. 50 CFM) (DUCTED TO OUTSIDE OF BUILDING)(ENERGY STAR W/ HUMIDISTAT) S C F SWITCH 125 VOLT GROUND FAULT OUTLET CEILING OR WALL LIGHT S KITCHEN EXHAUST SYSTEM VENTED TO OUTSIDE (MIN. 100 CFM)K 3 WAY SWITCH S 3 G.F.I. DIMMER SWITCH 220 VOLT OUTLET 220V ARC FAULT INTERRUPTION CIRCUIT AFIC ELEC. MAIN/SUB PANEL GARAGE DOOR OPENER G.D.O. GREEN NOTES 1.ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES,, CONDUITS, OR OTHER OPENINGS IN THE BUILDINGS ENVELOPE AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY, OR METAL PLATES. 2.FOR ALL NEW EQUIPMENT, AN OPERATION AND MAINTENANCE MANUAL INCLUDING, AT A MINIMUM THE ITEMS LISTED IN SECTION 4.410.1, SHALL BE COMPLETED AND PLACED IN THE BUILDING AT THE TIME OF FINAL INSPECTION 3.ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, OR SHEET METAL UNTIL THE FINAL SARTUP OF THE HEATING, COOLING AND VENT. EQUIPMENT 4.THE VOC CONTENT VERIFICATION CHECKLIST SHALL BE COMPLETED AND VERIFIED PRIOR TO FINAL INSPECTION APPROVAL. THE MANUFACTURERS SPECIFICATIONS SHOWING VOC CONTENT FOR ALL APPLICABLE PRODUCTS SHALL BE READILY AVAILABLE AT THE JOB SITE AND BE PROVIDED TO THE FIELD INSPECTOR FOR VERIFICATION 5.ALL NEW CARPET AND CARPET CUSHIONS INSTALLE DIN THE BUILDING INTERIOR SHALL MEET THE TESTING PRODUCT REQUIREMENTS OF ONE OF THE FOLLOWING 1. CARPET AND RUG INSTITUTES GREEN LABEL PLUS PROGRAM 2. CALIFORNIA DEPT. OF PUBLIC HEALTH'S SPECIFICATIONS 3. NSF/ANSI 140 AT THE GOLD LEVEL 4. SCIENTIFIC CERTIFICATIONS SYSTEMS INDOOR ADVANTAGE 6.80% OF THE TOTAL AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH ONE OR MORE OF THE FOLLOWING 1. VOC EMISSION LIMITS DEFINED IN THE CHPS HIGH PERFORMANCE PRODUCTS DATABASE 2. CERTIFIED UNDER UL GREENGUARD GOLD 3. CERTIFICATION UNDER THE RESILIENT FLOOR COVERING INSTITUTE 4. MEET THE CALIFORNIA DEPT. OF PUBLIC HEALTH'S SPECIFICATIONS 7.THE HEATING AND AIR CONDITIONING SYSTEMS SHALL BE SIZED AND DESIGNED USING ANSI/ACCA MANUAL J-2004, ANSI/ACCA 29-D-2009 OR ASHRAE HANDBOOKS AND HAVE THEIR EQUIPMENT SELECTED IUN ACCORDANCE WITH ANSI/ACCA 36-S MANUAL S-2004 8.WHEN A SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, THE COMBINED FLOW RATE OF ALL THE SHOWERHEADS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 2.0 GALLONS PER MINUTE AT 80psi, OR THE SHALL BE DESIGNED TO ONLY ALLOW ONE SHOWERHEAD TO BE IN OPERATION AT A TIME 9.THE FLOW RATES FOR ALL PLUMBING FIXTURES SHALL COMPLY WITH THE MAXIMUM FLOW RATES IN SECTION 4.303.1 10.THE HOT WATER SYSTEM SHALL NOT ALLOW MORE THAN 0.6 GALLONS OF WATER TO BE DELIVERED TO ANY FIXTURES BEFORE HOT WATER ARRIVES OR SHALL COMPLY WITH EITHER LOS ANGELES PLUMBING CODE SECTION 610.4.1.2 OR 610.4.1.3 EXISTING GARAGE FLOOR PLAN SHOWING AREA OF WORKSCALE: 1/4"=1'-0" #SIZE(WXH)DESCRIPTION REMARKS WINDOW SCHEDULE #SIZE (WXH)DESCRIPTION REMARKS DOOR SCHEDULE EXISTING EXISTING TO REMAIN(E) MECHANICAL 1.GROUND FAULT CIRCUIT-INTERRUPTION (GFCI) FOR PERSONNEL SHALL BE RPOVIDED AND INSTALLED IN READILY ACCESSIBLE AREA 2.ARC-FAULT CIRCUIT INTERRUPTION SHALL BE INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT 3.TAMPER-RESISTANT RECEPTACLES SHALL BE INSTALLED IN ALL AREAS SPECIFIED IN 210.52, ALL NONLOCKING TYPE 12-VOLT; 15- AND 20-AMPERE RECEPTACLES SHALL BE LISTED TAMPER-RESISTANT PLUMBING 1.PLUMBING FIXTURES ARE REQUIRED TO BE CONNECTED TO A SANITARY SEWER OR TO AN APPROVED SEWAGE DISPOSAL SYSTEM 2.KITCHEN SINKS, LAVATORIES, BATHTUBS, SHOWERS, BIDETS, LAUNDRY TUBS AND WASHING MACHINE OUTLETS SHALL BE PROVIDED WITH HOT AND COLD WATER AND CONNECTED TO AN APPROVED WATER SUPPLY 3.BATHTUB AND SHOWER FLOORS, WALLS ABOVE BATHTUBS WITH A SHOWERHEAD, AND SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR 4.PROVIDE ULTRA FLUSH WATER CLOSET FOR ALL NEW CONSTRUCTION, EXISTING SHOWERHEADS AND TOILETS MUST BE ADOPTED FOR LOW WATER CONSUMPTION 5.MECHANICAL, ELECTRICAL, AND PLUMBING PLANS ARE NOT REVIEWED AND ARE SUBJECT TO FIELD INSPECTION 6.THE FLOW RATES FOR ALL NEW PLUMBING FIXTURES SHALL COMPLY WITH THE MAXIMUM FLOW RATES SPECIFIED IN SECTION 4.303.1 PROPOSED ADU FLOOR PLAN SHOWING AREA OF WORKSCALE: 1/4"=1'-0" EXISTING EXISTING TO REMAIN(E) 1 2'-8"x6'-8"SINGLE HUNG1 3'-0"x3'-0"SINGLE HUNG 2 2 3'-0"x6'-8"SINGLE HUNG 1 1 1 2 K F F S S C 3'-0"x1'-0"TRANSOM 2 1 3 3'-10"x4'-0"SINGLE HUNG 3 3 SMOKE ALARMS SHALL BE LISTED IN ACCORDANCE WITH UL 217.(R314.1.1) NOTE: WALLS ABOVE BATHTUBS, AND IN SHOWER COMPARTMENTS, SHALL HAVE A SMOOTH, NONABSORBENT FINISH EXTENDING AT LEAST 6 FEET ABOVE THE FLOOR. TEMPERED 8' - 0 " 11 ' - 7 " 11 ' - 7 " 8' - 0 " 11 ' - 1 " 8' - 0 " 11 ' - 1 " 8' - 0 " 6' - 8 " 6' - 8 " 6' - 8 " CLG' MAX HT.MAX HT. MAX HT.MAX HT. CLG' CLG'CLG' 2' - 0 " 2' - 0 " 4:12 4:12 DR A W I N G D A T E : Ma r 5 , 2 0 2 6 ( 3 : 1 5 P M ) SHEET #: JO B A D D R E S S : 94 1 W M C F A D D E N A V E . / 9 4 1 W MC F A D D E N A V E . U N I T 2 SA N T A A N A , C A 9 2 7 0 7 NO . RE V I S I O N : DA T E : BY : EN G I N E E R : DE S I G N E D B Y : DR A W N B Y : RE V I E W E D B Y : PE R M I T N O . -- C. S . A. C . C. S . DE S I G N G R O U P : ENGINEER OF RECORD: PR O J E C T D E S C R I P T I O N HO M E RE M O D E L / ( N ) AD U STA N D L E Y S T R U C T U R A L D E S I G N CIV I L - S T R U C T U R A L E N G I N E E R S Located at: 17940 Ventura Blvd. Encino, CA 91316 Call: (213) 373-4513 A. C . EL E V A T I O N RO O F P L A N 01-A4 EAST ELEVATION VIEW SHOWING AREA OF WORK SCALE: 3/8"=1'-0" SOUTH ELEVATION VIEW SHOWING AREA OF WORK SCALE: 3/8"=1'-0" WEST ELEVATION VIEW SHOWING AREA OF WORK SCALE: 3/8"=1'-0" NORTH ELEVATION VIEW SHOWING AREA OF WORK SCALE: 3/8"=1'-0" TYPICAL EGRESS WINDOW TYPICAL WEEP SCREED DETAIL 5.7 MIN. SQ. FT. CLEAR OPENING NOTE: THESE DIMENSIONS SHOW MIN. CLEARANCE ONLY. 20" X 24" 3.32 SQ. FT. (NOT LEGAL) FINISHED FLOOR TOP OF FINISHED WINDOW SILL EGRESS OPENING NOTE: PROVIDE GLAZING AREA OF NOT LESS THAN 10% OF THE FLOOR AREA. PROVIDE NATURAL VENTILATION BY MEANS OF OPENABLE EXTERIOR OPENINGS WITH AN AREA NOT LESS THAN 5% OF THE FLOOR AREA, WITH A MIN. OF 5 SQ. FT.. FOOTING corrosion-resistant weep screed with a minimum vertical flange of 3 1/2 inches 2 LAYERS OF GRADE D PAPER 4" M I N GRADE PAVING 2" M I N . CertaFlash flex Flashing beyond Installed window CertainTeed Restoration Millwork trim board "Z" flashing, extending 1" each side. 2" vertical leg recommended. Weather resistance barrier Shim as required TYPICAL WINDOW FLASHING12 3 ARCH KEY NOTES: 1 RADEONEOAUOEM (LARRER)OREUOMAH EN CLASS 'A' RATED COMP. SHINGLE ROOF - OVER MIN. 30# FELT OVER PLYWOOD SHTG. PER STRUCT., TYP. ICC - 1463 (USE OWENS CORNING SHINGLES, (CRRC 0890-0010 OR EQ.) (U.N.O.) 2 3 OHAGIN STANDARD "FLAT STYLE ATTIC VENT ATTIC VENTILATION CALCULATION TOTAL NEW ATTIC AREA : 720 SQ. FT. PROVIDE VENTILATION EQUAL TO 1/150 USE EAVE VENTS AND EYEBROW VENTS 720/150= 4.8 SF X 144 SQ IN PER SQ FT = 691.2 SQ IN 10 X OHAGIN STANDARD "FLAT" STYLE ATTIC VENT (72 SQ. IN NFVA EA.) = 144 SQ. IN. TOTAL VENTING PROVIDED = 720 SQ IN TOTAL VENT REQUIRED = 691.2 SQ. IN ROOF PLAN SHOWING AREA OF WORK SCALE: 3/16"=1'-0" 1 1 1 1 22 2 2 3 DR A W I N G D A T E : Ma r 5 , 2 0 2 6 ( 3 : 1 5 P M ) SHEET #: JO B A D D R E S S : 94 1 W M C F A D D E N A V E . / 9 4 1 W MC F A D D E N A V E . U N I T 2 SA N T A A N A , C A 9 2 7 0 7 NO . RE V I S I O N : DA T E : BY : EN G I N E E R : DE S I G N E D B Y : DR A W N B Y : RE V I E W E D B Y : PE R M I T N O . -- C. S . A. C . C. S . DE S I G N G R O U P : ENGINEER OF RECORD: PR O J E C T D E S C R I P T I O N HO M E RE M O D E L / ( N ) AD U STA N D L E Y S T R U C T U R A L D E S I G N CIV I L - S T R U C T U R A L E N G I N E E R S Located at: 17940 Ventura Blvd. Encino, CA 91316 Call: (213) 373-4513 A. C . T2 4 - M A I N H O M E 03.A-6 DR A W I N G D A T E : Ma r 5 , 2 0 2 6 ( 3 : 1 5 P M ) SHEET #: JO B A D D R E S S : 94 1 W M C F A D D E N A V E . / 9 4 1 W MC F A D D E N A V E . U N I T 2 SA N T A A N A , C A 9 2 7 0 7 NO . RE V I S I O N : DA T E : BY : EN G I N E E R : DE S I G N E D B Y : DR A W N B Y : RE V I E W E D B Y : PE R M I T N O . -- C. S . A. C . C. S . DE S I G N G R O U P : ENGINEER OF RECORD: PR O J E C T D E S C R I P T I O N HO M E RE M O D E L / ( N ) AD U STA N D L E Y S T R U C T U R A L D E S I G N CIV I L - S T R U C T U R A L E N G I N E E R S Located at: 17940 Ventura Blvd. Encino, CA 91316 Call: (213) 373-4513 A. C . T2 4 - A D U 03.A-6.1 DR A W I N G D A T E : Ma r 5 , 2 0 2 6 ( 3 : 1 5 P M ) SHEET #: JO B A D D R E S S : 94 1 W M C F A D D E N A V E . / 9 4 1 W MC F A D D E N A V E . U N I T 2 SA N T A A N A , C A 9 2 7 0 7 NO . RE V I S I O N : DA T E : BY : EN G I N E E R : DE S I G N E D B Y : DR A W N B Y : RE V I E W E D B Y : PE R M I T N O . -- C. S . A. C . C. S . DE S I G N G R O U P : ENGINEER OF RECORD: PR O J E C T D E S C R I P T I O N HO M E RE M O D E L / ( N ) AD U STA N D L E Y S T R U C T U R A L D E S I G N CIV I L - S T R U C T U R A L E N G I N E E R S Located at: 17940 Ventura Blvd. Encino, CA 91316 Call: (213) 373-4513 A. C . ST R U C . N O T E S 02-S1 Footing, Stem Walls, Piers Stepftg/Retain'g Foundation Caisson, Piles, Grade Beams Firm or individual to be responsilbe for the Structural Observation: STRUCTURAL OBSERVATION PROGRAM to be the Structural Observer. DECLARATION BY OWNER Signature Date Observer is different from the Architect of Engineer of Record) I, the Owner of the project, declare that the above listed firm or individual is hired by me to be the DECLARATION BY ARCHITECT OR ENGINEER OF RECORD I, the Architect or Engineer of record, declare that the above listed firm or individual is designated by me to Hillside Special Anchors Structural Observer. Name: conc beam FOUNDATION Mat Foundation Owner: PROJECT ADDRESS: Description of Work: (required if the Structural FRAME Masonry Wall Frame Steel Braced Frame Steel Moment Frame STRUCTURAL OBSERVATION (only checked items are required) Concrete Moment Frame Phone:(916) 333-9225 WALL Others: Masonry Concrete Wood Others: Architect: Calif. Registration: Steel Deck Others: Wood Concrete DIAPHRAGM PERMIT APPL. NO.: Engineer: AND DESIGNATION OF THE STRUCTURAL OBSERVER Standley Standley C87675 1.MATERIAL DELIVERED TO THE CONSTRUCTION SITE SHALL BE PROTECTED FROM RAIN OR OTHER SOURCES OF MOISTURE. (9.407.4) 2.ALL STUDS, JOISTS, RAFTERS, AND BLOCKING'S SHALL BE DF-L NO. 2 AS GRADED BY WWPGR, ALL POSTS AND BEAMS SHALL DF-L N0. 1 OR BETTER AS GRADED BY WWPGR. UNO. 3.ALL LUMBER IN CONTACT WITH CONCRETE SHALL BE DF-LARCH PRESSURE TREATED. 4.ALL NEW SHEATHING USE FOR BRACING SHALL BE 15/32" CDX, 5-PLY PANEL CONSTRUCTION WITH SPAN RATING OF 32/16 OR BETTER AS RATED BY AMERICAN PLYWOOD ASSOC. 5.ANY NAIL IN CONTACT WITH PRESSURE TREATED LUMBER SHALL BE HOT-DIPPED GALVANIZED OR STAINLESS STEEL. 6.BUILDING MATERIAL WITH VISIBLE SIGNS OF WATER DAMAGE SHALL NOT BE INSTALLED. WALL AND FLOORING FRAMING SHALL NOT BE ENCLOSED UNTIL IT IS INSPECTED AND FOUND TO BE SATISFACTORY BY BUILDING INSPECTOR. (9.505.3) 1.THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO STARTING OF WORK. 2.THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PILL-BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF HOOK-UP. 3.THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. 4.CONTINUOUS SPECIAL INSPECTION BY A REGISTERED DEPUTY INSPECTOR IS REQUIRED FOR SPRAYED-ON FIREPROOFING AND HIGH LOAD DIAPHRAGMS 5.CONSTRUCTION WASTE WILL BE HANDLED BY CITY OF LOS ANGELES CERTIFIED HAULER AND SHALL BE REDUCED BY 50% OF ITS OVERALL WASTE. CALIFORNIA WASTE SERVICES, PERMIT# PER-09-058 621 W. 152ND ST., GARDENA, CA 90247 1.ALL NON-EPOXY GROUT SHALL BE RAPID SET BRAND OR EQUIV. INSTALLED PER THE MANUFACTURERS SPEC'S, LARR24654. 2.ALL EPOXY TYPE GROUT SHALL BE SIMPSON SET BRAND STRUCTURAL EPOXY OR EQUIV. INSTALLED PER THE MANUFACTURERS SPECIFICATIONS, LA RR#25279. 3.CLEAN OUT ALL DRILLED BORINGS AND CRACKS PRIOR TO APPLICATION OF GROUT. DEPUTY INSPECTION REQUIRED AT ALL TIME OF PROCEDURE. 4.CONTINUOUS SPECIAL INSPECTION BY A REGISTERED DEPUTY INSPECTOR IS REQUIRED FOR HIGH-LIFT GROUTING. 1.ALL STEEL REINFORCEMENT BARS SHALL BE 60,000 PSI YIELD STRENGTH CONFORMING TO ASTM STD A615, UNLESS NOTED OTHERWISE. 2.ALL STEEL REINFORCEMENT TIES AND STIRRUPS SHALL BE 40,000 PSI YIELD STRENGTH CONFORMING TO ASTM STD A615, UNLESS NOTED OTHERWISE. 3.ALL STEEL REINFORCEMENT HOOKS SHALL BE PER ACI318 STANDARD HOOKS SCHEDULE. 4.ALL BENDS IN REINFORCEMENT BARS SHALL BE MADE COLD. 5.STEEL REINFORCEMENT SHALL BE FREE OF LOOSE FLAKY RUST, MUD, OIL, AND OTHER COATINGS WHICH MAY REDUCE BOND STRENGTH. 6.STEEL REINFORCING SHALL BE ACCURATELY PLACED IN CONCRETE FORMS WITH THE APPROPRIATE CLEAR COVER MAINTAINED. 7.SPLICES IN STEEL REINFORCEMENT FOR SLABS AND RETAINING WALL SHALL BE A MINIMUM OF 40 BAR DIAMETER OR 24 INCHES WHICH EVER IS LARGER. 8.SHOP WELDING FOR STEEL REINFORCEMENT SHALL BE PERFORMED IN A LADBS LICENSED FABRICATION SHOP OR CALIFORNIA LICENSED FABRICATION SHOP. 9.FIELD WELDING FOR STEEL REINFORCEMENT SHALL BE PERFORMED BY A LADBS CERTIFIED WELDERS OR CALIFORNIA LICENSED WELDER. CONTINUOUS SPECIAL INSPECTION BY A REGISTERED DEPUTY INSPECTOR IS REQUIRED FOR FIELD WELDING. 1.ALL EXISTING FOUNDATIONS & FOOTINGS SHALL BE CLEANED OFF PRIOR TO POURING OF NEW CONCRETE FOR PROPER BONDING. 2.CEMENT SHALL CONFORM TO THE SPECIFICATION FOR PORTLAND CEMENT ASTM C150. 3.WATER USED IN MIXING CONCRETE SHALL BE CLEAN AND FREE FROM INJURIOUS AMOUNTS OF OILS, ACIDS, ALKALIS, SALTS, ORGANIC MATERIALS, OR OTHER SUBSTANCES THAT MAY BE DELETERIOUS TO CONCRETE OR REINFORCEMENT BARS. 4.ALL CONCRETE WORK SHALL BE DONE WITH MINIMUM OF 3000PSI CONCRETE, UNLESS NOTED OTHERWISE. 5.CONTINUOUS SPECIAL INSPECTION BY A REGISTERED DEPUTY INSPECTOR IS REQUIRED FOR CONCRETE STRENGTH GREATER THAN 2500 PSI, DRIVEN DEEP FOUNDATION, CAST-IN PLACE DEEP FOUNDATIONS, ENGINEERING MASONRY, PRE-STRESSED CONCRETE, HIGH LOAD DIAPHRAGMS AND SPECIAL MOMENT-RESISTING CONCRETE FRAMES. 6.ALL CONCRETE SHALL BE 3,000 PSI IN 28 DAYS & DEPUTY INSPECTION IS REQUIRED, UNLESS NOTED OTHERWISE. 7.PLACEMENT OF STEEL REINFORCEMENT IN CONCRETE SHALL BE AS FOLLOWED: A.3 INCHES FROM FACE OF CONCRETE CAST IF IT IS AGAINST AND/OR PERMANENTLY EXPOSED TO EARTH B.2 INCHES FROM FACE OF CONCRETE CAST IF IT IS EXPOSED TO EARTH AND/OR WEATHER. C.1-1/2" INCHES FROM FACE OF CONCRETE CAST IF IT IS NOT EXPOSED TO WEATHER AND/OR IN CONTACT WITH EARTH. 1.PRE-MOISTEN EXCAVATIONS FOR FOOTING & SLAB PRIOR TO POURING CONCRETE. THE CONSULTING SOILS ENGINEER SHALL CHECK MOISTURE CONDITIONS. 2.ALL RECOMMENDATIONS OF THE CONSULTING GEOLOGIST MUST BE INCORPORATED INTO THE DESIGN OR SHOWN AS NOTES ON THE PLANS IF APPLICABLE. 3.IF ADVERSE SOIL CONDITIONS ARE ENCOUNTERED, A SOILS INVESTIGATION REPORT MAY BE REQUIRED. (1802.2.1) 1.THE OWNER SHALL EMPLOY A STATE OF CALIFORNIA REGISTERED CIVIL OR STRUCTURAL ENGINEER OR LICENSED ARCHITECT TO PERFORM THE STRUCTURAL OBSERVATION. THE DEPARTMENT OF BUILDING AND SAFETY (LADBS) RECOMMENDS THE USE OF THE ENGINEER OR ARCHITECT RESPONSIBLE FOR THE STRUCTURAL DESIGNS THAT ARE INDEPENDENT OF THE CONTRACTOR. 2.THE STRUCTURAL OBSERVER SHALL PROVIDE EVIDENCE OF EMPLOYMENT BY THE OWNER OR THE OWNER'S REPRESENTATIVE. A LETTER FROM THE OWNER, THE OWNER'S REPRESENTATIVE OR A COPY OF THE AGREEMENT FOR SERVICES SHALL BE SENT TO THE BUILDING INSPECTOR BEFORE THE FIRST SITE VISIT. 3.THE OWNER OR OWNER'S REPRESENTATIVE SHALL COORDINATE AND CALL FOR A MEETING BETWEEN THE ENGINEER OR ARCHITECT RESPONSIBLE FOR THE STRUCTURAL DESIGN, STRUCTURAL OBSERVER, CONTRACTOR, AFFECTED SUBCONTRACTORS AND DEPUTY INSPECTORS. THE PURPOSE OF THE MEETING SHALL BE TO IDENTIFY THE MAJOR STRUCTURAL ELEMENTS AND CONNECTIONS THAT AFFECT THE VERTICAL AND LATERAL LOAD SYSTEMS OF THE STRUCTURE AND TO REVIEW SCHEDULING OF THE REQUIRED OBSERVATIONS. A RECORD OF THE MEETING SHALL BE INCLUDED IN THE FIRST OBSERVATION REPORT SUBMITTED TO THE BUILDING INSPECTOR. 4.THE STRUCTURAL OBSERVER SHALL PERFORM SITE VISITS AT THOSE STEPS IN THE PROGRESS OF THE WORK THAT ALLOW FOR CORRECTION OF DEFICIENCIES WITHOUT SUBSTANTIAL EFFORT OR UNCOVERING OF THE WORK INVOLVED. AT A MINIMUM, THE LISTED SIGNIFICANT CONSTRUCTION STAGES ON THE FOLLOWING STRUCTURAL OBSERVATION AND/OR SIGNIFICANT CONSTRUCTION STAGES TABLE REQUIRE A SITE VISIT AND AN OBSERVATION REPORT FROM THE STRUCTURAL OBSERVER. 6.THE STRUCTURAL OBSERVER SHALL PREPARE A REPORT OF THE STRUCTURAL OBSERVATION REPORT FORM IN/FORM.08 (PART 1) FOR EACH SIGNIFICANT STAGE OF CONSTRUCTION OBSERVED. THE ORIGINAL OF THE STRUCTURAL OBSERVATION REPORT SHALL BE SENT TO THE BUILDING INSPECTOR'S OFFICE AND SHALL BE SIGNED AND SEALED (WET STAMP) BY THE RESPONSIBLE STRUCTURAL OBSERVER. ONE COPY OF THE OBSERVATION REPORT SHALL BE ATTACHED TO THE APPROVED PLANS. THE COPY ATTACHED TO THE PLANS SHALL BE SIGNED AND SEALED (WET STAMP) BY THE RESPONSIBLE STRUCTURAL OBSERVER OR THEIR DESIGNEE. COPIES OF THE REPORT SHALL ALSO BE GIVEN TO THE OWNER, CONTRACTOR, AND DEPUTY INSPECTOR. ANY DEFICIENCY NOTED ON THE OBSERVATION REPORT WILL BECOME THE RESPONSIBILITY OF THE STRUCTURAL ENGINEER OF RECORD TO VERIFY ITS COMPLETION BY HIM (HER), OR BY A REGISTERED DEPUTY INSPECTOR AT THE DISCRETION OF THE STRUCTURAL OBSERVER. 7.A FINAL OBSERVATION REPORT AND THAT OF THE REGISTERED DEPUTY INSPECTOR MUST BE SUBMITTED WHICH SHOWS THAT ALL OBSERVED DEFICIENCIES WERE RESOLVED AND STRUCTURAL SYSTEM GENERALLY CONFORMS TO THE APPROVED PLANS AND SPECIFICATIONS. THE DEPARTMENT OF BUILDING AND SAFETY (LADBS) WILL NOT ACCEPT THE STRUCTURAL WORK WITHOUT THIS FINAL OBSERVATION REPORT AND THAT OF THE REGISTERED DEPUTY INSPECTOR (WHEN PROVIDED) AND THE CORRECTION OF SPECIFIC DEFICIENCIES NOTED DURING NORMAL BUILDING INSPECTION. 8.THE STRUCTURAL OBSERVER SHALL PROVIDE THE ORIGINAL STAMPED AND SIGNED STRUCTURAL OBSERVATION REPORT TO THE CITY'S DEPARTMENT OF BUILDING AND SAFETY INSPECTION OFFICE. 9.WHEN THE OWNER ELECTS TO CHANGE THE STRUCTURAL OBSERVER OF RECORD, THE OWNER SHALL: A.NOTIFY THE BUILDING INSPECTOR IN WRITING BEFORE THE NEXT INSPECTION BY SUBMITTING COMPLETED "STRUCTURAL OBSERVATION PROGRAM AND DESIGNATION OF THE STRUCTURAL OBSERVER" FORM IN/FORM.08 (PART 2) B.CALL AN ADDITIONAL PRE-CONSTRUCTION MEETING, AND C.FURNISH THE REPLACEMENT STRUCTURAL OBSERVER WITH A COPY OF ALL PREVIOUS OBSERVATION REPORTS. THE REPLACEMENT STRUCTURAL OBSERVER SHALL APPROVE THE CORRECTION OF THE ORIGINAL OBSERVED DEFICIENCIES UNLESS OTHERWISE APPROVED BY PLAN CHECK SUPERVISION. THE POLICY OF THE DEPARTMENT SHALL BE TO CORRECT ANY PROPERTY NOTED DEFICIENCIES WITHOUT CONSIDERATION OF THEIR SOURCE. 10.THE ENGINEER OR ARCHITECT OF RECORD SHALL DEVELOP ALL CHANGES RELATING TO THE STRUCTURAL SYSTEMS. THE BUILDING DEPARTMENT SHALL REVIEW AND APPROVE ALL CHANGES TO THE APPROVED PLANS AND SPECIFICATIONS. STRUCTURAL OBSERVATION CONSTRUCTION STAGE ELEMENTS TO BE OBSERVED CONCRETE LUMBER GROUT STEEL REINFORCEMENT EARTHWORK 1.CONTINUOUS SPECIAL INSPECTION BY A REGISTERED DEPUTY INSPECTOR IS REQUIRED FOR FIELD WELDING, HIGH STRENGTH BOLTING AND SPRAYED-ON FIREPROOFING. 2.LADBS LICENSED FABRICATOR IS REQUIRED FOR STRUCTURAL STEEL. 3.ALL WELDING SHALL BE SHOP WELDED BY A CERTIFIED WELDING SHOP, UNLESS NOTED OTHERWISE. 4.SHOP WELDING FOR STRUCTURAL STEEL & LIGHT GAUGE STEEL SHALL BE PERFORMED IN A CERTIFIED FABRICATOR SHOP OR CALIFORNIA LICENSED FABRICATOR SHOP. 5.FIELD WELDING FOR STRUCTURAL STEEL & LIGHT GAUGE STEEL SHALL BE PERFORMED BY A CERTIFIED WELDERS OR CALIFORNIA LICENSED WELDER. CONTINUOUS SPECIAL INSPECTION BY A REGISTERED DEPUTY INSPECTOR IS REQUIRED FOR FIELD WELDING. STEEL CONSTRUCTION DEAD LOAD: HORIZONTAL SYSTEMS: ·ROOF CONSTRUCTION 15 PSF. ·CEILING CONSTRUCTION 10 PSF. ·FLOOR CONSTRUCTION 15 PSF. VERTICAL SYSTEMS: ·LIGHT-FRAME WALL CONSTRUCTION 20 PSF. ·MASONRY WALL CONSTRUCTION 120 PCF. ·CONCRETE WALL CONSTRUCTION 160 PCF. LIVE LOAD: ROOF SYSTEMS: ·SLOPE < 4:12 20 PSF. ·SLOPE =/> 4:12 16 PSF. ·ROOF SOLAR 5 PSF ATTIC SYSTEMS: ·W/O STORAGE SPACE 20 PSF. ·W/ STORAGE SPACE 30 PSF. FLOOR SYSTEMS: ·BEDROOM AREAS 30 PSF. ·OTHER AREAS 40 PSF WALLS: ·EXTERIOR WALLS 15 PSF. ·INTERIOR WALLS 10 PSF DESIGN LOAD DATA NO CONCRETE TOPPING ASSUMED IN DEAD LOAD CALCULATIONS. CONTRACTOR TO VERIFY IN FIELD GREEN NOTES 1.ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES,, CONDUITS, OR OTHER OPENINGS IN THE BUILDINGS ENVELOPE AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY, OR METAL PLATES. 2.FOR ALL NEW EQUIPMENT, AN OPERATION AND MAINTENANCE MANUAL INCLUDING, AT A MINIMUM THE ITEMS LISTED IN SECTION 4.410.1, SHALL BE COMPLETED AND PLACED IN THE BUILDING AT THE TIME OF FINAL INSPECTION 3.ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, OR SHEET METAL UNTIL THE FINAL SARTUP OF THE HEATING, COOLING AND VENT. EQUIPMENT 4.THE VOC CONTENT VERIFICATION CHECKLIST SHALL BE COMPLETED AND VERIFIED PRIOR TO FINAL INSPECTION APPROVAL. THE MANUFACTURERS SPECIFICATIONS SHOWING VOC CONTENT FOR ALL APPLICABLE PRODUCTS SHALL BE READILY AVAILABLE AT THE JOB SITE AND BE PROVIDED TO THE FIELD INSPECTOR FOR VERIFICATION 5.ALL NEW CARPET AND CARPET CUSHIONS INSTALLE DIN THE BUILDING INTERIOR SHALL MEET THE TESTING PRODUCT REQUIREMENTS OF ONE OF THE FOLLOWING 1. CARPET AND RUG INSTITUTES GREEN LABEL PLUS PROGRAM 2. CALIFORNIA DEPT. OF PUBLIC HEALTH'S SPECIFICATIONS 3. NSF/ANSI 140 AT THE GOLD LEVEL 4. SCIENTIFIC CERTIFICATIONS SYSTEMS INDOOR ADVANTAGE 6.80% OF THE TOTAL AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH ONE OR MORE OF THE FOLLOWING 1. VOC EMISSION LIMITS DEFINED IN THE CHPS HIGH PERFORMANCE PRODUCTS DATABASE 2. CERTIFIED UNDER UL GREENGUARD GOLD 3. CERTIFICATION UNDER THE RESILIENT FLOOR COVERING INSTITUTE 4. MEET THE CALIFORNIA DEPT. OF PUBLIC HEALTH'S SPECIFICATIONS 7.THE HEATING AND AIR CONDITIONING SYSTEMS SHALL BE SIZED AND DESIGNED USING ANSI/ACCA MANUAL J-2004, ANSI/ACCA 29-D-2009 OR ASHRAE HANDBOOKS AND HAVE THEIR EQUIPMENT SELECTED IUN ACCORDANCE WITH ANSI/ACCA 36-S MANUAL S-2004 8.WHEN A SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, THE COMBINED FLOW RATE OF ALL THE SHOWERHEADS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 2.0 GALLONS PER MINUTE AT 80psi, OR THE SHALL BE DESIGNED TO ONLY ALLOW ONE SHOWERHEAD TO BE IN OPERATION AT A TIME 9.THE FLOW RATES FOR ALL PLUMBING FIXTURES SHALL COMPLY WITH THE MAXIMUM FLOW RATES IN SECTION 4.303.1 DESCRIPTION NAILINGSCHEDULE BLOCKING BETWEEN CEILING JOISTS OR RAFTERS TO TOP PL. # AND TYPE SPACING & LOCATION ROOF 4-8D BOX (21/2″ × 0.113″) OR TOE NAIL 3-8D COMMON (21/2″ × 0.131″); OR 3-10D BOX (3″ × 0.128″); OR 3-3" × 0.131″ NAILS TOE NAIL CEILING JOIST TO TOP PL. 4-8D BOX (21/2″ × 0.113″); ORPER JOIST, 3-8D COMMON (21/2″ × 0.131″); OR 3-10D BOX (3″ × 0.128″); OR 3-3″ × 0.131″ NAILS PER JOIST, TOE NAIL CEILING JOIST NOT ATTACHED TO PARALLEL RAFTER, LAPS OVER PARTITIONS 4-10D BOX (3″ × 0.128″); OR 3-16D COMMON (31/2″ × 0.162″); OR 4-3″ × 0.131″ NAILS FACE NAIL CEILING JOIST ATTACHED TO PARALLEL RAFTER (HEEL JOINT)TABLE 1, S-1 FACE NAIL COLLAR TIE TO RAFTER, FACE NAIL OR 11/4″ × 20 GA. RIDGE STRAP TO RAFTER 4-10D BOX (3″ × 0.128″); OR 3-10D COMMON (3″ × 0.148″); OR 4-3″ × 0.131″ NAILS FACE NAIL EACH RAFTER RAFTER OR ROOF TRUSS TO PLATE 3-16D BOX NAILS (31/2″ × 0.135″); OR 3-10D COMMON NAILS (3" × 0.148″); OR 4-10D BOX (3″ × 0.128″); OR 4-3″ × 0.131″ NAILS 2 TOE NAILS ON ONE SIDE AND 1 TOE NAIL ON OPPOSITE SIDE OF EACH RAFTER OR TRUSS ROOF RAFTERS TO RIDGE, VALLEY OR HIP RAFTERS OR ROOF RAFTER TO MINIMUM 2″ RIDGE BEAM 4-16D (31/2″ × 0.135″); OR 3-10D COMMON (31/2″ × 0.148″); OR 4-10D BOX (3″ × 0.128″); OR 4-3″ × 0.131″ NAILS TOE NAIL 3-16D BOX 31/2″ × 0.135″); OR 2-16D COMMON (31/2″ × 0.162″); OR 3-10D BOX (3″ × 0.128″); OR 3-3″ × 0.131″ NAILS END NAIL WALL DESCRIPTION # AND TYPE SPACING & LOCATION STUD TO STUD (NOT AT BRACED WALL PANELS) 16D COMMON (31/2″ × 0.162″)24″ O.C. FACE NAIL 10D BOX (3″ × 0.128″); OR 3″ × 0.131″ NAILS 16″ O.C. FACE NAIL STUD TO STUD AND ABUTTING STUDS AT INTERSECTING WALL CORNERS (AT BRACED WALL PANELS) 16D BOX (31/2″ × 0.135″); OR 3" × 0.131" NAILS 12″ O.C. FACE NAIL 16D COMMON (31/2″ × 0.162″)16″ O.C. FACE NAIL BUILT-UP HEADER (2″ TO 2″ HEADER WITH 1/2″ SPACER) 16D COMMON (31/2″ × 0.162″)16″ O.C. EACH EDGE FACE NAIL 16D BOX (31/2″ × 0.135″)12″ O.C. EACH EDGE FACE NAIL CONTINUOUS HEADER TO STUD 5-8D BOX (21/2″ × 0.113″); OR 4-8D COMMON (21/2″ × 0.131″); OR 4-10D BOX (3″ × 0.128″) TOE NAIL TOP PLATE TO TOP PLATE 16D COMMON (31/2″ × 0.162″)16″ O.C. FACE NAIL 10D BOX (3″ × 0.128″); OR 3″ × 0.131″ NAILS 12″ O.C. FACE NAIL DOUBLE TOP PLATE SPLICE FOR SDCS A-D2 WITH SEISMIC BRACED WALL LINE SPACING < 25' 8-16D COMMON (31/2″ × 0.162″); OR 12-16D BOX (31/2″ × 0.135″); OR 12-10D BOX (3″ × 0.128″); OR 12-3″ × 0.131″ NAILS FACE NAIL ON EACH SIDE OF END JOINT (MINIMUM 24″ LAP SPLICE LENGTH EACH SIDE OF END JOINT)DOUBLE TOP PLATE SPLICE SDCS D0, D1, OR D2; AND BRACED WALL LINE SPACING ≥25' 12-16D (31/2″ × 0.135″) BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING (NOT AT BRACED WALL PANELS) 16D COMMON (31/2″ × 0.162″)16″ O.C. FACE NAIL 16D BOX (31/2″ × 0.135″); OR 12″ O.C. 3″ × 0.131″ NAILS 12″ O.C. FACE NAIL BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING (AT BRACED WALL PANEL) 3-16D BOX (31/2″ × 0.135″); OR 2-16D COMMON (31/2″ × 0.162″); OR4-3″ × 0.131″ NAILS 3 EACH 16″ O.C. FACE NAIL 2 EACH 16″ O.C. FACE NAIL 4 EACH 16″ O.C. FACE NAIL TOP OR BOTTOM PLATE TO STUD 4-8D BOX (21/2″ × 0.113″); OR 3-16D BOX (31/2″ × 0.135″); OR 4-8D COMMON (21/2″ × 0.131″); OR 4-10D BOX (3″ × 0.128″); OR 4-3″ × 0.131″ NAILS TOE NAIL 3-16D BOX (31/2″ × 0.135″); OR 2-16D COMMON (31/2″ × 0.162″); OR 3-10D BOX (3″ × 0.128″); OR 3-3″ × 0.131″ NAILS END NAIL TOP PLATES, LAPS AT CORNERS AND INTERSECTIONS 3-10D BOX (3″ × 0.128″); OR 2-16D COMMON (31/2″ × 0.162″); OR 3-3″ × 0.131″ NAILS FACE NAIL 1″ × 6″ SHEATHING TO EACH BEARING 3-8D BOX (21/2″ × 0.113″); OR 2-8D COMMON (21/2″ × 0.131″); OR 2-10D BOX (3″ × 0.128″); OR 2 STAPLES, 1″ CROWN, 16 GA., 13/4″ LONG FACE NAIL 1″ × 8″ AND WIDER SHEATHING TO EACH BEARING 3-8D BOX (21/2″ × 0.113″); OR3-8D COMMON (21/2″ × 0.131″); OR 3-10D BOX (3″ × 0.128″); OR 3 STAPLES, 1″ CROWN, 16 GA., 13/4″ LONG FACE NAILWIDER THAN 1″ × 8″ 4-8D BOX (21/2″ × 0.113″); OR 3-8D COMMON (21/2″ × 0.131″); OR 3-10D BOX (3″ × 0.128″); OR 4 STAPLES, 1″ CROWN, 16 GA., 13/4″ LONG JOIST TO SILL, TOP PLATE OR GIRDER 4-8D BOX (21/2″ × 0.113″); OR 3-8D COMMON (21/2″ × 0.131″); OR 3-10D BOX (3″ × 0.128″); OR 3-3″ × 0.131″ NAILS TOE NAIL RIM JOIST, BAND JOIST OR BLOCKING TO SILL OR TOP PLATE (ROOF APPLICATIONS ALSO) 8D BOX (21/2″ × 0.113″)4" O.C. TOE NAIL 8D COMMON (21/2″ × 0.131″); OR 10D BOX (3″ × 0.128″); OR 3″ × 0.131″ NAILS) 6″ O.C. TOE NAIL RIM JOIST, BAND JOIST OR BLOCKING TO SILL OR TOP PLATE (ROOF APPLICATIONS ALSO) 3-8D BOX (21/2″ × 0.113″); OR 2-8D COMMON (21/2″ × 0.131″); OR 3-10D BOX (3″ × 0.128″); OR 2 STAPLES, 1″ CROWN, 16 GA., 13/4″ LONG FACE NAIL 2″ SUBFLOOR TO JOIST OR GIRDER 3-16D BOX (31/2″ × 0.135″); OR 2-16D COMMON (31/2″ × 0.162″)BLIND AND FACE NAIL 2″ PLANKS (PLANK & BEAM‒FLOOR & ROOF) 3-16D BOX (31/2″ × 0.135″); OR 2-16D COMMON (31/2″ × 0.162″)AT EACH BEARING, FACE NAIL WALL BAND OR RIM JOIST TO JOIST 3-16DCOMMON (31/2″ × 0.162″) 4-10 BOX (3″ × 0.128″), OR 4-3″ × 0.131″ NAILS; OR 4-3″ × 14 GA. STAPLES, 7/16″ CROWN END NAIL BUILT-UP GIRDERS AND BEAMS, 2-INCH LUMBER LAYERS 20D COMMON (4″ × 0.192″); OR NAIL EACH LAYER AS FOLLOWS: 32″ O.C. AT TOP AND BOTTOM AND STAGGERED. 10D BOX (3″ × 0.128″); OR 3″ × 0.131″ NAILS 24″ O.C. FACE NAIL AT TOP AND BOTTOM STAGGERED ON OPPOSITE SIDES AND: 2-20D COMMON (4″ × 0.192″); OR 3-10D BOX (3″ × 0.128″); OR 3-3″ × 0.131″ NAILS FACE NAIL AT ENDS AND AT EACH SPLICE LEDGER STRIP SUPPORTING JOISTS OR RAFTERS 4-16D BOX (31/2″ × 0.135″); OR 3-16D COMMON (31/2″ × 0.162″); OR 4-10D BOX (3″ × 0.128″); OR 4-3″ × 0.131″ NAILS AT EACH JOIST OR RAFTER, FACE NAIL BRIDGING TO JOIST 2-10D (3″ × 0.128″)EACH END, TOE NAIL RAFTER SLOPE 3:12 TABLE 1 4:12 5:12 7:12 9:12 12:12 RAFTER SPACING 12 16 24 12 16 24 12 16 24 12 16 24 12 16 24 12 16 24 4 5 7 3 4 5 3 3 4 3 3 3 ROOF SPAN (ft) (inches)12 20 28 36 REQUIRED # OF 16d COMMON NAILS 3 3 3 3 3 3 6 8 11 5 6 8 4 5 7 4 4 5 3 4 4 3 3 4 8 10 15 6 8 12 5 6 9 4 5 7 4 4 6 3 4 4 10 13 19 8 10 15 6 8 12 5 6 9 5 6 7 3 4 5 (E) FOUNDATION TO REMAIN, TYP. (E) FOUNDATION TO REMAIN, TYP. (E) FOUNDATION TO REMAIN, TYP. (E) CRAWL SPACE 2 -- TYP. HDU 4 HDU 4 (N) 4" SLAB ON GRADE W/ #4 BARS @ 16" O.C. EA. WAY (E) FOUNDATION TO REMAIN, TYP. 1 -- TYP. 1 -- TYP. 1 -- TYP. 1 -- TYP. 3 -- TYP. 3 -- TYP. 4 -- TYP. HDU 4 HDU 4 HDU 4 HDU 4 HDU 4 HDU 4 HDU 4 HDU 4 HDU 4 HDU 4 HDU 4 HDU 4 HDU 4 HDU 4 1 -- TYP. 3 -- TYP. NOTE: NEW FOUNDATION SHALL BE DONE UTILIZING AN "ABC SLOT CUT METHOD" EXCAVATING MAX 4' SLOT WIDTH (N) 4" SLAB ON GRADE W/ #4 BARS @ 16" O.C. EA. WAY1 -- TYP. 4 3 1 2 24" LAP TYP. TOP BARS 4" SLAB PER PLAN, TYP. 12" MIN. 24 " M I N . P.T. MUDSILL W/ (N) 1/2"Ø ANCHOR BOLTS AND 3"x3"x5/16" WASHERS @ 6'-0" O.C. W/ 7" MIN. EMB. STUD WALL PER PLANS SHEAR PANEL'G. PER SCHEDULE (WHERE OCCURS) 8" MI N . G.I. WEEP SCREED EXTERIOR FINISH PER PLANS EXTERIOR SLAB FOOTING (1-STORY) NOTE: SEE SCHEARWALL SCHEDULE FOR A.B. SPACING IN SHEARWALL #4 BAR @ 16" O.C.E.W, TYP. 10 MIL VISQUINE, (PLASTIC VAPOR BARRIER) 4" THICK BASE OF 1 2" CLEAN AGGREGATE2 - #4 BARS T&B 13 4" MIN. POST PER PLANS 5 8"Ø SIMPSON "SSTB16" 12 5 8" M I N . 14 1 16 " MA X . 17 8" HOLD DOWN @ NEW SLAB SIMPSON HOLD DOWN PER PLANS POST PER PLANS FOUNDATION PER PLANS 13 4" MIN. 10 " MI N . 5 8"Ø ANCHOR BOLT SET WITH SIMPSON SET- EPOXY (ER-265) OR EQUIV., SPECIAL DEPUTY INSP. REQ'D. HOLD DOWN @ EXISTING FOUNDATION SIMPSON HOLD DOWN PER PLANS INTERIOR SLAB FOOTING DETAIL -- -- FOR SLAB INFO. SEESHEARWALL WHERE OCCURS PER PLANS STUD WALL PER PLANS (N) SLAB PLANS 12" 3" C L R . 24 " M I N . P.T. MUDSILL W/ (N) 1/2"Ø ANCHOR BOLTS AND 3"x3"x5/16" WASHERS @ 12" O.C. UNDER SHEAR WALL AND 4'-0" O.C. ELSEWHERE W/ 7" MIN. EMB. 2 - #4 BARS T&B 4" THICK BASE OF 1 2" CLEAN AGGREGATE 10 MIL VISQUEEN, (PLASTIC VAPOR BARRIER) 6DOWEL DETAIL 7 (N) FTG.(E) FTG. P.T. MUDSILL W/ ANCHOR BOLTS PER PLAN S.S.T. "LSTA36" @ (N) AND (E) SILL PL. CONNECTION (WHERE OCCURS) REBAR PER PLANS, TYP. 24"8" #4 DOWELS, T&B EPOXY SET WITH SIMPSON SET-XP EPOXY (RR25744), SPECIAL DEPUTY INSP. REQ'D. 85 DR A W I N G D A T E : Ma r 5 , 2 0 2 6 ( 3 : 1 6 P M ) SHEET #: JO B A D D R E S S : 94 1 W M C F A D D E N A V E . / 9 4 1 W MC F A D D E N A V E . U N I T 2 SA N T A A N A , C A 9 2 7 0 7 NO . RE V I S I O N : DA T E : BY : EN G I N E E R : DE S I G N E D B Y : DR A W N B Y : RE V I E W E D B Y : PE R M I T N O . -- C. S . A. C . C. S . DE S I G N G R O U P : ENGINEER OF RECORD: PR O J E C T D E S C R I P T I O N HO M E RE M O D E L / ( N ) AD U STA N D L E Y S T R U C T U R A L D E S I G N CIV I L - S T R U C T U R A L E N G I N E E R S Located at: 17940 Ventura Blvd. Encino, CA 91316 Call: (213) 373-4513 A. C . FO U N D A T I O N P L A N 02-S2 ADU FOUNDATION PLAN (PROPOSED) SHOWING AREA OF WORK SCALE: 1/4"=1'-0" HOLD DOWN LEGEND: NEW 4X6 POST W/ HDU4 HOLD DOWN PER DETAIL #1 NEW 4X6 POST W/ HDU4 HOLD DOWN PER DETAIL #10/SD1 MAIN HOUSE FOUNDATION PLAN (PROPOSED) SHOWING AREA OF WORK SCALE: 1/4"=1'-0" (E) C.J. TO REMAIN (E ) C . J . T O R E M A I N (E ) C . J . T O R E M A I N (N) 4X6 HDR. (E) HDR.(E) HDR. (E) HDR. (E) HDR. (E) HDR. (E ) H D R . 1 L = 5'-3" 2 -- TYP. 1 -- TYP. (N)2X10 C.J. @ 16" (N)2X10 C.J. @ 16" (N) 4X6 HDR.(N) 4X6 HDR. (N) 4X6 HDR. (N) 4X6 HDR. (N ) 4 X 6 H D R . L = 8'-0" L = 8'-0" 1L = 8'-0" 1 L = 8'-0" 1 L = 7'-1" 1 L = 3'-9" 3 -- TYP. 2 -- TYP. 3 -- TYP. 3 -- TYP. 3 -- TYP. 1 -- TYP. 1 -- TYP. (N ) 4 X 6 H D R . 1 1 (N) BEAM 2 -- TYP. (N) 4 X 6 P O S T (N) 4 X 6 P O S T (N) 4 X 6 P O S T (N) 4 X 6 P O S T (N) 4 X 6 P O S T (N) 4 X 6 P O S T (N) 4 X 6 P O S T (N) 4 X 6 P O S T (N) 4 X 6 P O S T (N) 4 X 6 P O S T (N) 4 X 6 P O S T (N) 4 X 6 P O S T (N) 4 X 6 P O S T (N) 4 X 6 P O S T (N) 4 X 6 P O S T HDU 4 HDU 4 HDU 4 HDU 4 HDU 4 HDU 4 HDU 4 HDU 4 HDU 4 HDU 4 HDU 4 HDU 4 HDU 4 HDU 4 4 -- TYP. 4 -- TYP. 4 3 1 2 POST CONNECTION DETAIL HEADER SCHEDULE HEADER SEE SCHEDULE HEADER SCHEDULE MIN. HEADER SIZEMAX OPENING WIDTH BEARING WALL NON-BRG. WALL 4'-0" 6'-0" 8'-0" 10'-0" 12'-0"4 X 14 4 X 12 4 X 10 4 X 6 4 X 4 4 X 6 4 X 8 4 X 10 4 X 12 4 X 8 SEE ARCHITECTURAL PLANS TOP PLATE A35 UNDER HEADER 4 X 8 OR SMALLER 'EPC' UNDER 4 X 10 OR 4 X 12 'ECC" LARGER U.N.O. DBL. STUD UNDER HEADER 4 X 8 OR SMALLER 4 X POST UNDER 4 X 10 OR LARGER U.N.O. SIMPSON "A35" WHEN OPEN'G WIDTH EXCEEDS 5'-0" ("A35'S" @2 X 6 STUDS) 2 - 16d (3 - 16d @ HDRS. DEEPER THAN 4") USE 2 - 2 X KING STUDS AT OPENINGS WIDER THAN 6' - 0" 2 X BLK'G 16d @ 12" O.C. STAGGERED TYP. DBL. FULL HT.STUDS WHEN OPENING WIDTH EXCEEDS 5' - 0" SIMPSON "A35" WHEN OPEN'G WIDTH EXCEEDS 5' - 0" ("A35'S" @ 2 X 6 STUDS) OPTION 1 OPTION 2 BEAM MEMBER PER PLAN, TYP. SIMPSON "ECCQ" COLUMN CAP OR EQUIV., TYP. (AT SLOPING BEAMS USE CAPS W/ SKEWED AND/OR SLOPED STRAPS TO ACCOMODATE CONSTRUCTION). (N) 4x6 POST (N) 4X6 POST BEAM MEMBER PER PLAN, TYP. SIMPSON "ECCQ" COLUMN CAP OR EQUIV., TYP. (AT SLOPING BEAMS USE CAPS W/ SKEWED AND/OR SLOPED STRAPS TO ACCOMODATE CONSTRUCTION). (N) PLYWOOD SHEAR WALL PER PLAN (WHERE OCCURS) SEE TABLE 1, S-1 B.N. UPLIFT FRAMING CLIP A35 FRAMIUNG ANCHOR AT EACH BAY 2-2X TOP PL. STUD WALL PER PLANS E.N. 2X SOLID BLKG' PER PLAN C.J. PER PLANS RAFTER PER PLANS EAVE FRAMING DETAIL FRAMING @ GABLE ENDS (N) 15 32" WOOD STRUCTURAL PANEL W/ 8d @ 6"/6"/12" PLYWOOD SHEAR WALL PER PLAN (WHERE OCCURS) E.N. RAKE WALL RAFTERS PER PLANS E.N. (N) BARGE RAFTER 2X BLOCKING VERGE RAFTER ROOFING TYP E.N. 2X BLOCKING @ 8'-0" O.C.MAX. C.J.PER PLANS 3-10d NAILS 2X4 @ 4'-0" O.C. A35 FRAMING ANCHOR PER SHEARWALL SCHED. 2-2X TOP PLATES A35 FRAMING ANCHOR PER SHEARWALL SCHED. 2X RIM JOIST 2X BLOCKING @ 8'-0" O.C.MAX. 6 75 LINTEL SIZE SCHEDULE SPANH UP TO 6'-0"5 1/2" 6'-0" TO 8'-0"7 1/4" 8'-0" TO 10'-0"9 1/4" LINTEL SIZES GIVEN ARE MINIMUMS LARGER SIZES SHALL BE USED WHERE CALLED FOR BY PLANS OR BY SPECIFIC DETAILS MATCH STUD WIDTH H SE E SC H E D U L E SOLID BUILT-UP BLOCK @ 24" O.C. MAXIMUM WITH 2-16d NAILS FROM EACH SIDE A34 TOP AND BOTTOM OF JAMB AT OPENINGS MORE THAN 3'-0" IN EXTERIOR WALLS ONLY 2 X BLOCKING AT MIDHEIGHT OR 8'0" MAX. 2 X SILL PLATE W/ " A.B. PER PLANS HOLD DOWN AS OCCURS MIN 3/4" DRYPACK AS LEVELING BASE UNLESS BASE IS LEVEL WITHIN 1/8" IN 10'-0" NOTE: WALL FRAMING OVER FRAMED FLOOR SIMILAR 5' MIN. 9' MAX.DOUBLE STUD JAMB AT OPENINGS MORE THAN 4'-0" JACK STUD AT LINTEL USE DOUBLE JACK STUD AT OPENINGS MORE THAN 6'-0" U.N.O. A35 CLIP AT OPENINGS MORE THAN 3'-0" AT EXT. WALLS ONLY SOLID OR BUILT-UP LINTEL OVER OPENING DOUBLE TOP PLATE FOR SPLICE SEE DET. 5 3-16d MIN TYPICAL WALL FRAMING DETAIL DR A W I N G D A T E : Ma r 5 , 2 0 2 6 ( 3 : 1 6 P M ) SHEET #: JO B A D D R E S S : 94 1 W M C F A D D E N A V E . / 9 4 1 W MC F A D D E N A V E . U N I T 2 SA N T A A N A , C A 9 2 7 0 7 NO . RE V I S I O N : DA T E : BY : EN G I N E E R : DE S I G N E D B Y : DR A W N B Y : RE V I E W E D B Y : PE R M I T N O . -- C. S . A. C . C. S . DE S I G N G R O U P : ENGINEER OF RECORD: PR O J E C T D E S C R I P T I O N HO M E RE M O D E L / ( N ) AD U STA N D L E Y S T R U C T U R A L D E S I G N CIV I L - S T R U C T U R A L E N G I N E E R S Located at: 17940 Ventura Blvd. Encino, CA 91316 Call: (213) 373-4513 A. C . CE I L I N G F R A M I N G P L A N 02-S3 ADU CEILING FRAMING PLAN (PROPOSED) SHOWING AREA OF WORK SCALE: 1/4"=1'-0" PLYWOOD SHEAR ANC. SHEARWALL SCHEDULE 15/32" STRCUT. 1 LTP4 @ 15" O.C. EDGE NAILING 10d COM. @ 4" O.C. TAG CAPACITY NOTES: 1)NAILING IS IN ADDITION TO THE MINIMUM REQUIREMENTS OF C.B.C. - TABLE 2304.9.1 2)HDU4 HOLD DOWN AT EACH END 3)SOLID BLOCK AND NAIL ALL PLYWOOD EDGES 4)PROVIDE 1 2" EDGE DISTANCE FOR PLYWOOD BOUNDARY NAILING 1 510 plf FIELD NAILING 10d COM. @ 16" O.C. ANC. BOLT 5 8" @ 32" O.C.* 15/32" STRCUT. 1 LTP4 @ 16" O.C.10d COM. @ 6" O.C. 2 340 plf10d COM. @ 16" O.C.5 8" @ 32" O.C.* PER MFR.N/A3 4945 lb/ftN/A PER MFR.SSW 24X8 MAIN HOUSE CEILING FRAMING PLAN (PROPOSED) SHOWING AREA OF WORK SCALE: 1/4"=1'-0" (N ) 2 X 1 0 R I D G E B O A R D (E) ROOF (E) ROOF (E ) R I D G E B O A R D (N) 2X6 R.R. @ 16" O.C. (N) 2X6 R.R. @ 16" O.C. (E) R.R. TO REMAIN (E) R.R. TO REMAIN 1 -- TYP. 2 -- TYP. 1 2 4 3 RIDGE BEAM PER PLANS ROOF RAFTERS PER PLANS 2-16d EACH SIDE ROOFING PER PLANS 20 GA.x 1-1/4" STRAP @ 48" O.C. (N) COLLAR TIES @ 48" O.C. 4-10d NAILS RIDGE DETAIL NEW EXISTING (N) R.R. PER PLANS (N) R.R. PER PLANS W/ 2-10d NAILS @ 8" O.C. (N) 2X BLKG' @ 48" O.C. (N) LSTA26 @ 48" O.C. B.N.. (E) R.R. TO REMAIN DIAPHRAGM CONNECTION DETAIL DR A W I N G D A T E : Ma r 5 , 2 0 2 6 ( 3 : 1 6 P M ) SHEET #: JO B A D D R E S S : 94 1 W M C F A D D E N A V E . / 9 4 1 W MC F A D D E N A V E . U N I T 2 SA N T A A N A , C A 9 2 7 0 7 NO . RE V I S I O N : DA T E : BY : EN G I N E E R : DE S I G N E D B Y : DR A W N B Y : RE V I E W E D B Y : PE R M I T N O . -- C. S . A. C . C. S . DE S I G N G R O U P : ENGINEER OF RECORD: PR O J E C T D E S C R I P T I O N HO M E RE M O D E L / ( N ) AD U STA N D L E Y S T R U C T U R A L D E S I G N CIV I L - S T R U C T U R A L E N G I N E E R S Located at: 17940 Ventura Blvd. Encino, CA 91316 Call: (213) 373-4513 A. C . RO O F F R A M I N G P L A N 02-S4 ADU ROOF FRAMING PLAN (PROPOSED) SHOWING AREA OF WORK SCALE: 3/8"=1'-0"