Loading...
HomeMy WebLinkAbout2102 S Flower St - DEF - Mechanical Unit Support at Roof - PlanCITY OF SANTA ANA Planning and Building Agency QTY. MARK 2 CU-1-11 1-2 MAKE I MODEL DAIKIN I RXYQ168AAYDB WEIGHT I Lf 761 LBS 423/» NOTES:1. HORIZONTAL &VERTICAL SEISMIC CAPACITY: 375 LBS 2. UNIT ON GRADE. 3 1Y" 2 OPER. HC 2 03; 28%" ------- Y 4 4Y �%4 5/"0 THRD. ROD NEOPRENE WASHER -17 Deferred Approval These documents (drawings, specifications, or calculations) have been prepared by other design professionals or consultants who are licensed and/or authorized to prepare such documents in California. These documents have been examined by JAMA for design intent and have been found to meet the appropriate structural requirements and the project specifications. RV rlawrence nATF 12/20/2025 JOHN A. MARTIN & ASSOCIATES, INC. STRUCTURAL ENGINEERS 950 S. Grand Ave., Fourth Floor, Los Angeles, CA 90015 Design Load Review Reviewed for design loads only as they affect the primary structure. Not responsible for design, dimensions or quality of material RV rlawrence nATF 12/20/2025 JOHN A. MARTIN & ASSOCIATES, INC. STRUCTURAL ENGINEERS 950 S. Grand Ave., Fourth Floor, Los Angeles, CA 90015 MOUNT # SIZE DURO DEFL LOAD 1 thru 4 50D %" 230 LBi proved ruh MIT ISSUANCE 0 I Bf 4 ISO. LAYOUT & LOCATION '16"0 HOLE (2) PLACES USE %11 0 STAINLESS STEEL HILTI KB-TZ2 ANCHORS IN MIN. 3000 PSI NW CONCRETE W/ 2Y" MIN. NOMINAL EMBED., 3" MIN. EDGE DISTANCE AND 4" MIN. CONCRETE THICKNESS. INSTALL WITH SPECIAL INSPECTION PER THE I CC ESR- 4266. �TYP. STEEL SUPPORT � JOB NAME: SANTA ANA MEMORIAL PARK AQUATICS CENTER M. W. SAUSSE & CO., INC. OUST: WEST -TECH MECHANICAL 28744 WITHERSPOON PKWY, VALENCIA, CA 91355 PHONE: (661) 257-3311 FAX: (661) 257-7673 OUST. P.O. MECH. ENGR. : i reoeo FF-EQ-3 - - „ilbl? en �� ��� ���� cu'rihol sv�ten,s MARK: CU 1 1, 1-2 T STEEL PLATE (6))X YX Y16))) RIBBED NEOPRENE PAD REVISIONS: A: REV TO ITEM (3/4/2025) JA C: [a f Fr - _ -e6g`J 3/4/2025 DRN : JA DATE: Master ID Date: ENG : JA 11 /18/2024 DRAWING NO.: FIP26681 -S8076-3A CITY OF SANTA ANA Planning and Building Agency MARK MAKE MODEL WEIGHT Lf B± MOUNT # 1 TH RU 4 CU - 21 51 61 7 RXF18AXVJU 101 LBS 24" 14116 L CU - 3, 4 RXTQ48TBVJU A 176 LBS 24%6" 13%" G DAIKIN CU - 8 RXF24AXVJU 101 LBS 24" 141316" L CU - 9 RX30WM VJU 9 133 LBS 23% 13%)f L NOTE(S): 1. ALL DIMENSIONS IN INCHES 2. SPRING DEFLECTION: 1" 3. FINISH: POWDER COATED. 4. STEEL DESIGNED & FURNISHED BY OTHERS. A Deferred Approval These documents (drawings, specifications, or calculations) have been prepared by other design professionals or consultants who are licensed and/or authorized to prepare such documents in California. These documents have been examined by JAMA for design intent and have been found to meet the appropriate structural requirements and the project specifications. BY rlawrence DATE 12/20/2025 JOHN A. MARTIN & ASSOCIATES, INC. STRUCTURAL ENGINEERS 950 S. Grand Ave., Fourth Floor, Los Angeles, CA 90015 Design Load Review Reviewed for design loads only as they affect the primary structure. Not responsible for design, dimensions or quality of material RV rlawrence nATF 12/20/2025 JOHN A. MARTIN & ASSOCIATES, INC. STRUCTURAL ENGINEERS 950 S. Grand Ave., Fourth Floor, Los Angeles, CA 90015 STEEL WASHE NEOPRENE GROM (#6 ISOLATOR H.C.A.I. PRE —APPROVAL PENDING No. OPM-0203-22 �`r IV �L) U U IV 8Y MAX. ALLOW. LOAIDS.10 10 M. W. SAUSSE & Co. INC. 28744 WITHERSPOON PKWY, VALENCIA, CA 91355 PHONE: (661) 257-3311 FAX: (661) 257-7673 RMU-EQ-1 Vvibr%ation& seismic control systems JOB NAME: CUST : OUST. P.O.: MECH. ENGR. : MARK: HORIZ: 860 LBS SANTA ANA MEMORIAL PARK AQUATICS CENTER WEST -TECH MECHANICAL CU-213, 4153 6, 7, 8, 9 31LIZER BOLT 4/4 VE"?T. SPRING OD DEFL LOAD L 2" 1" 5 proved Pd RMIT ISSUANCE G 2" 1" 75 LBS �Lf� Bf ISO. LAYOUT & LOCATION %6170 HOLE (2) PLACES USE Y8" A-307 HEX BOLTS TO ATTACH TO STEEL BENEATH. SEE NOTE #4 3Ys» OPER. HGT. � (UP).. I REVISIONS 620 LBS A: REV TO ANCHORAGE (3/4/2025 JA B: C: D: 72/70/20, Master ID Date: DRN : JA I ENG : JA DATE: 11118/2024 DRAWING N0. P26681-S8076-4A CITY OF SANTA ANA Planning and Building Agency MARK I MAKE I MODEL I WEIGHT I RES WT. (EA.) CU-2, 51 61 7 DAIKIN RXF18AXVJU 101 LBS 40 LBS. CU-8 DAIKIN RXF24AXVJU 101 LBS 40 LBS. %"0 x 2" LG. STUD 2�f I 71 yl 6 26 2 7 2/'/l 1 .09 9 W. I I PLAN VIEW NOTE(S): 1. FRAME IS A FULLY WELDED CONSTRUCTION. 2. FOR ANCHORAGE OF RES TO STRUCTURE, USE Y4"-14 ITW TEKS SCREW INTO MIN. 20 GA MATERIAL (12) PER RES AS SHOWN. M. W. SAUSSE & C001 INC, I JOB NAME: SANTA ANA MEMORIAL PARK AQUATICS CENTER CUST : WEST -TECH MECHANICAL 28744 WITHERSPOON PKWY, VALENCIA, CA 91355 PHONE: (661) 257-3311 FAX: (661) 257-7673 CUST. P.O. VvibrIsmic MECH. ENGR.: 1®RES-EQ A TKT . ��1,� JI/6R ation & seicontrol systems MARK: • `�' `" —�! f " 7 �! Deferred Approval These documents (drawings, specifications, or calculations) have been prepared by other design professionals or consultants who are licensed and/or authorized to prepare such documents in California. These documents have been examined by JAMA for design intent and have been found to meet the appropriate structural requirements and the project specifications. RV rlawrence nATF 12/20/2025 JOHN A. MARTIN & ASSOCIATES, INC. STRUCTURAL ENGINEERS 950 S. Grand Ave., Fourth Floor, Los Angeles, CA 90015 Design Load Review Reviewed for design loads only as they affect the primary structure. Not responsible for design, dimensions or quality of material BY rlawrence DATE 12/20/2025 JOHN A. MARTIN & ASSOCIATES, INC. STRUCTURAL ENGINEERS 950 S. Grand Ave., Fourth Floor, Los Angeles, CA 90015 it 72/70/20, 16 GA. 2 CURB CAP � FLASHING TO EXTEND 8" ABOVE TAPERED INSULATION (this seems sufficient but please coordinate with insulation sub) REVISIONS: A: 1---*--7 m- I 9 %" OX 2" LG. MOUNTING STUD NT16111 in \ � I 14 1 Y"x3x3 ATTACHMENT PLO 14 GA. RES SECTION VIEW A FOR PE Master ID Date: 16 GA. CURB CAP i � � JCC IV V I C ffL ���3 ISOMETRIC DRN : PDG DATE: DRAWING NO.: ENG : PDG 12/10/2025 P26681-S8676-16 pprovehd RMIT ISSUANCE MARK I MAKE CU-31 4 DAIKIN a 3y 13%q. ISOLATOR 3y W I I I I I I I I I I I L MODEL RXTQ48TBVJUA lip I!: g— � WEIGHT 176 LBS RES WT. (EA.) PLAN VIEW 40 LB S. NOTE(S): 1. FRAME IS A FULLY WELDED CONSTRUCTION. 2. FOR ANCHORAGE OF RES TO STRUCTURE, USE Y4"-14 ITW TEKS SCREW INTO MIN. 20 GA MATERIAL (12) PER RES AS SHOWN. M. W. SAUSSE & CO., INC. 28744 WITHERSPOON PKWY, VALENCIA, CA 91355 PHONE: (661) 257-3311 FAX: (661) 257-7673 1' RES-EQ vibration & seismic control systems Y8 "4 x 2" LG. STUD JOB NAME: SANTA ANA MEMORIAL PARK AQUATICS CENTER CUST : WEST -TECH MECHANICAL OUST. P.O.: MECH. ENGR. : MARK: CU-314 Deferred Approval These documents (drawings, specifications, or calculations) have been prepared by other design professionals or consultants who are licensed and/or authorized to prepare such documents in California. These documents have been examined by JAMA for design intent and have been found to meet the appropriate structural requirements and the project specifications. RV rlawrence nATF 12/20/2025 JOHN A. MARTIN & ASSOCIATES, INC. STRUCTURAL ENGINEERS 950 S. Grand Ave., Fourth Floor, Los Angeles, CA 90015 Design Load Review Reviewed for design loads only as they affect the primary structure. Not responsible for design, dimensions or quality of material R, rlawrence nATF 12/20/2025 JOHN A. MARTIN & ASSOCIATES, INC. STRUCTURAL ENGINEERS 950 S. Grand Ave., Fourth Floor, Los Angeles, CA 90015 .� CIV11.FCA rc FLASHING TO EXTEND 8" AB �6� 16 GA. 2 CURB CAP � VE TAPERED INSULATION (this seems sufficient but please coordinate with insulation sub� REVISIONS: A: Y8 OX 2" LG. MOUNTING STUD WOOD N Al LER )/4 ly X3X3 ATTACHMENT PLO 14 GA. RES SECTION VIEW �a CITY OF SANTA ANA Planning and Building Agency JRAproved FORMIT ISSUANCE Master ID Date: 16 GA. CURB CAP i'`-�i��j JCC IVV IC �fL ISOMETRIC DRN : PDG DATE: DRAWING NO. : ENG : PDG 12/ 10/2025 P26681 -S8076-1 1 MARK I MAKE CU-9 I DAIKIN I 3y 3y MODEL RX30WM VJU 9 I I I I I I I I I I I lip I!: WEIGHT 133 LBS 9 —I RES WT. (EA.) 40 LB S. Y8 "0 x 2$$ LG. STUD n Deferred Approval These documents (drawings, specifications, or calculations) have been prepared by other design professionals or consultants who are licensed and/or authorized to prepare such documents in California. These documents have been examined by JAMA for design intent and have been found to meet the appropriate structural requirements and the project specifications. RV rlawrence nATF 12/20/2025 JOHN A. MARTIN & ASSOCIATES, INC. STRUCTURAL ENGINEERS 950 S. Grand Ave., Fourth Floor, Los Angeles, CA 90015 Design Load Review Reviewed for design loads only as they affect the primary structure. Not responsible for design, dimensions or quality of material RV rlawrence nATF 12/20/2025 JOHN A. MARTIN & ASSOCIATES, INC. STRUCTURAL ENGINEERS 950 S. Grand Ave., Fourth Floor, Los Angeles, CA 90015 21/1/16 7 1 6 �/8 26 2 7 21Y1 6 PLAN VIEW NOTE(S): 1. FRAME IS A FULLY WELDED CONSTRUCTION. 2. FOR ANCHORAGE OF RES TO STRUCTURE, USE Y4"-1 4 INTO MIN. 20 GA MATERIAL (12) PER RES AS SHOWN. M. W. SAUSSE & CO., INC. 28744 WITHERSPOON PKWY, VALENCIA, CA 91355 PHONE: (661) 257-3311 FAX: (661) 257-7673 RES-EQ vibration & seismic control systems TW TEKS SCREW JOB NAME: SANTA ANA MEMORIAL PARK AQUATICS CENTER CUST : WEST -TECH MECHANICAL CUST. P.O.: MECH. ENGR. : MARK: CU-9 u 16 GA. CURB CAP y FLASHING TO EXTEND 8" AB VE TAPERED INSULATION (this seems sufficient but please coordinate with insulation E!, �h1 A: [7 9a 3/" OX 2" LG. MOUNTING STUD WOOD NAILER $$00 ATTACHMENT P L. 14 GA. RES SECTION VIEW A CITY OF SANTA ANA Planning and Building Agency FORIpproved EERMIT ISSUANCE Master Date: 16 GA. CURB CAP i�-►�y Jtt IV V I t ptL ISOMETRIC DRN : PDG DATE: DRAWING NO. : ENG : PDG 12/10/2025 P26681-S8076-12 CALCULATE HORIZONTAL WIND FORCE (F IN LBS., DIMS. IN FT): EXPOSURE CATEGORY: C BUILDING HEIGHT (hr):0 VELOCITY EXPOSURE FACTOR (KZ) (TABLE 29.3-1): 0.85 TOPOGRAPHIC FACTOR KZT = (1+K1K2K3)2 (EQ. 26.8-1) K1,K2 AND K3 FROM (FIGURE 26.8-1): K1 =0 K2 =0 K3 =0 KZT =1 Kd (DIRECTIONALITY FACTOR, TABLE 26.10-1) =0.90 OCCUPANCY/RISK CATEGORY =III *(FOR WIND SPEED MAP SELECTION - SEE FIG. 26.5-1A TO 1C) WIND VELOCITY (V IN MPH) =95 17.7 HORIZONTAL LOAD: (GCr) =1.9 (REDUCEABLE, SEE SECTION 29.4.1) Af =22.16 ft2 (VERTICAL FACE OF EQUIPMENT NORMAL TO HORIZ. WIND PRESSURE) (29.4-2) Fh = qh(GCr)Af =744.2 lbs VERTICAL LOAD: (GCr) =1.5 (REDUCEABLE, SEE SECTION 29.4.1) Ar =10.21 ft2 (HORIZONTAL FACE OF EQUIPMENT NORMAL TO VERT. WIND PRESSURE) (29.4-3) Fv = qh(GCr)Ar =270.8 lbs DESIGN LOADS FOR ANCHORAGE CALCULATIONS Fh = 744.19 lbs Fv =270.76 lbs REV. A: REV. TO ANCHORAGE (3-4-2025) JA JOB NAME: SANTA ANA MEMORIAL PARK AQUATICS CENTER M. W. SAUSSE' & CO., INC. CUST.: WEST-TECH MECHANICAL PREPARED BY: MECH. ENG.: DATE : MARK: CU-1-1, 1-2 SHEET NO.: 18-Nov-24 P26681-S8076-C3A CALCULATIONS FOR RIGID ANCHORAGE - WIND LOADING (ASCE 7-16) FIND VELOCITY PRESSURE (qh) = 0.00256*KZ*KZT*Kd*V2 (LBS/FT2) IF GROUND IS FLAT ENTER THE VALUE OF ZERO FOR ALL VELOCITY PRESSURE (qh) = HORIZONTAL AND VERTICAL WIND LOADS FROM SECTION 29.5.1 JA 3/4/2025 BY DATE 12/20/2025 These documents (drawings, specifications, or calculations) have been prepared by other design professionals or consultants who are licensed and/or authorized to prepare such documents in California. These documents have been examined by JAMA for design intent and have been found to meet the appropriate structural requirements and the project specifications. JOHN A. MARTIN & ASSOCIATES, INC. STRUCTURAL ENGINEERS 950 S. Grand Ave., Fourth Floor, Los Angeles, CA 90015 Deferred Approval rlawrence BY DATE 12/20/2025 Reviewed for design loads only as they affect the primary structure. Not responsible for design, dimensions or quality of material JOHN A. MARTIN & ASSOCIATES, INC. STRUCTURAL ENGINEERS 950 S. Grand Ave., Fourth Floor, Los Angeles, CA 90015 Design Load Review rlawrence CALCULATIONS FOR VIBREX TYPE FF-EQ VIBRATION ISOLATORS/SEISMIC RESTRAINTS - 2018 IBC/2019 CBC, LRFD CALCULATES WORST CASE LOADING FOR (4) TO (14) ISOLATORS. (UNITS: LBS & INCHES) USING COMBINED LOAD EQUATIONS 16-5: U = 1.2D + 1.0E & 16-7: U = 0.9D + 1.0E SEISMIC FORCES - CH. 13 OF ASCE 7 13.3-2: Fp =1.6*SDS*Ip*Wp (MAX)= 1043.48 lbs 13.3-1: Fp =(0.4*ap*SDS/(Rp/Ip))(1+2z/hr)Wp = 260.87 lbs 13.3-3: Fp =0.3*SDS*Ip*Wp (MIN)= 195.65 lbs CONTROLLING HOR. SEISMIC FORCE: Fp = 260.87 lbs OVERTURNING MOMENT: M=Fp*HC.G.= 8527.21 lb-in * SUPP. VERT. SEISM. FORCE: Fpv = 0.2SDSWp = 130.44 lbs DESIGN SPECTRAL RESP. ACCELERATION: SDS = 0.86 IMPORTANCE FACTOR: Ip = 1.00 COMPONENT AMPLIFICATION FACTOR: ap = 2.50 COMP. RESPONSE MODIFICATION FACTOR: Rp = 2.50 EQUIPMENT ELEVATION / ROOF ELEVATION: z/hr = 0.00 (WITH RESPECT TO GRADE) UNIT LOCATED INDOORS OR OUTDOORS = OUTDOORS Fh FROM PREVOUS CALCULATION (IF APPLICABLE)= 744.19 lbs Fv FROM PREVOUS CALCULATION (IF APPLICABLE)= 270.76 lbs WIND OVERTURNING MOMENT: Mw = FhHw = 24325.63 lb-in EQUIPMENT WEIGHT & GEOMETRY EQUIPMENT WEIGHT: Wp = 761.00 lbs L:= 21.19 in B:= 14.38 in EX:= 2.12 in EY:= 1.44 in HEIGHT TO CG.: HC.G.= 32.69 in CNTR OF AREA OF WINDWARD FACE: HW = 32.69 in NO. OF ISOLATORS (Ni)= 4.00 ISOLATOR GROUP PROPERTIES MOMENT OF INERTIA ABOUT X AXIS: IX = 826.56 in4 a (DIR. OF Vdir-CRIT. ANCHOR): tan-1(EY/EX)= 34.16 MOMENT OF INERTIA ABOUT Z AXIS: IZ = 1795.64 in4 b: g - a == 180.00 g (DIR. OF Vrot-CRIT. ANCHOR): tan-1(B/L)= 34.16 q (DIR. OF Fph FOR MAX UPLIFT): tan-1((L*IX)/(B*IY))= 34.16 FROM SEISMIC LOADS (LOAD APPLIED TO CRITICAL ANGLE)FROM WIND LOADS (LOAD PERPENDICULAR TO UNIT LENGTH) VERTICAL REACTIONS (WITH 1.2D OR 0.9D)VERTICAL REACTIONS (WITH 1.2D OR 0.9D): Rm (DUE TO OVERTURNING MOMENT)= 179.21 lbs Rm (DUE TO OVERTURNING MOMENT)= 423 lbs Re MAX (DUE TO ECCENTRICITY):= 52.18 lbs Re MAX (DUE TO ECCENTRICITY):= 45.66 lbs Re MIN (DUE TO ECCENTRICITY): = 27.72 lbs Re MIN (DUE TO ECCENTRICITY): = 34 lbs Rv MAX (DUE TO VERTICAL LOADS): = 260.91 lbs Rv MAX (DUE TO VERTICAL LOADS): = 160.61 lbs Rv MIN (DUE TO VERTICAL LOADS): = 138.62 lbs Rv MIN (DUE TO VERTICAL LOADS): = 103.54 lbs PMAX (MAX DOWNWARD REACTION): Rm+Re MAX+Rv MAX = 492.30 lbs PMAX : Rm+Re MAX+Rv MAX = 629.3 lbs PMIN (MAX UPLIFT/ANCH. POINT - IF POS.): Rm+Re MIN-Rv MIN = 68.32 lbs PMIN: Rm+Re MIN-Rv MIN (0 IF NEGATIVE)=353.8 lbs HORIZONTAL REACTIONS:HORIZONTAL REACTION: Vrot (SHEAR DUE TO ECCENTRICITY):= 6.52 lbs VMAX = Vdir =186.05 lbs Vdir (DIRECT SHEAR): = 65.22 lbs VMAX (TOTAL SHEAR/ISOLATOR):= 71.74 lbs FOR DESIGN OF CONCRETE ANCHORS WITH CONCRETE FAILURE MODE(S) GOVERNING W0 PER ASCE 7-10, NOTE C, TABLE 13.6-1 = 2.00 PMIN (WITH OVERSTRENGTH): W0Rm+Re MIN-Rv MIN =247.53 lbs VMAX (WITH OVERSTRENGTH):=143.48 lbs WIND LOAD(S) GOVERN(S) THE DESIGN OF THE ANCHORS!! HEIGHT OF ISO: Hiso = 1.38 # OF ANCHOR BOLTS: n = 2 ANCHOR BOLT TENSION: Tblt = PMIN/n+Vab*Hiso/(1.5*n)= 262.15 lbs ANCHOR BOLT SHEAR: Vblt = VMAX/n = 93.02 lbs ANCHOR BOLT DIAMETER:=3/8 JOB NAME: SANTA ANA MEMORIAL PARK AQUATICS CENTER M.W. SAUSSE' & CO., INC. CUST.: WEST-TECH MECHANICAL PREPARED BY : MECH. ENG.: DATE : MARK: CU-1-1, 1-2 SHEET NO. : TYPE OF ANCHOR BOLT: STAINLESS STEEL HILTI KB-TZ2 ANCHOR BOLT IN MIN. 3000psi. SEE SHEETS -C3.1A & C3.2A P26681-S8076-C3.1A 18-Nov-24 JA 3/4/2025 STEEL STRENGTH (TENSION AND SHEAR) n =2 (NUMBER OF BOLTS PER ANCHOR POINT) INPUT da =0.375 in (DIAMETER OF ANCHOR BOLT) SEISMIC?:NO *TOPSIDE OF DECK?:NO STEEL:STAINLESS Nsa = 6180 lbs (FROM TABLES 4 & 5) Vsa =4885 lbs (FROM TABLES 6 & 7) FsN =0.75 (TENSION STRENGTH REDUCTION FACTOR FOR DUCTILE STEEL; ACI-318 17.3.3) FsV =0.65 (SHEAR STRENGTH REDUCTION FACTOR FOR DUCTILE STEEL; ACI-318 17.3.3) FsN*Nsa = 4635 lbs (ACI 318, 17.4.1.2) ¬ DESIGN STEEL TENSION STRENGTH FsV*Vsa = 3175.25 lbs (ACI 318, 17.5.1.2) ¬ DESIGN STEEL SHEAR STRENGTH CONCRETE CONCRETE BREAKOUT TENSION STRENGTH INPUT hnom =2.5 in (NOMINAL EMBED., ESR TABLE 3 & 9) ha =4 in (MEMBER THICKNESS, USE AT LEAST MIN. VALUES IN ESR, TABLE 3 OR 9) hef =2 in (EFFECTIVE EMBED., ESR TABLE 3 OR 9) Cac = 5.5 in Cmin =2.50 hmin =4.00 smin =3.65 Ca1 =3 in (USE AT LEAST Ca,min GIVEN IN TABLE 3 & 9 IN ESR, INCREASE IF NECESSARY) INPUT Ca2 =3 in (USE AT LEAST Ca,min & ³ Ca1 GIVEN IN TABLE 3 & 9 IN ESR, INCREASE IF NECESSARY) Ca3 =4.5 in (USE AT LEAST Ca,min & ³ Ca2 GIVEN IN TABLE 3 & 9 IN ESR, INCREASE IF NECESSARY) Ca4 =4.5 in (USE AT LEAST Ca,min & ³ Ca2 GIVEN IN TABLE 3 & 9 IN ESR, INCREASE IF NECESSARY) SMIN =4.5 in (CLOSEST SPACING DIST. BETWEEN (2) ANCHORS IN THE ANCHOR GROUP) S1 =0 in (USE AT LEAST Smin FROM TABLES 3 & 9, ENTER 0 IF SINGLE ANCHOR) S2 =4.5 in (USE AT LEAST Smin FROM TABLES 3 & 9, ENTER 0 IF SINGLE ANCHOR) Yec,N =1 (ACI 17.4.2.4; 1.0 WHEN NO LOAD ECCENTRICITY) f'c =3000 psi (CONCRETE COMPRESSIVE STRENGTH) l =1.00 (1.0 FOR NW CONCRETE, 0.68 FOR STRUCTURAL SAND LW, 0.6 FOR ALL LW, 4.1.12 OF ESR) CRACKED CONCRETE CONDITION… kc =21 (ESR TABLE 4 & 5) Yc,N =1.00 (FROM ESR TABLE 4 & 5) FcN =0.65 (PULLOUT/CONCRETE BREAKOUT STRENGTH REDUCTION; ESR TABLES 4 & 5) hef CHECK = hef' =2 in (IF 3 OR MORE EDGES ARE LESS THAN 1.5*hef, 17.4.2.3 OF THE ACI-318) SIDE^ = min(Ca,2;1.5hef')+S2+min(Ca4;1.5hef') =10.50 in (LENGTH OF SIDE PERPENDICULAR TO SHEAR / SMALLEST EDGE DIST.) SIDEll = min(Ca1;1.5hef')+S1+min(Ca3;1.5hef') =6.00 in (LENGTH OF SIDE PARALLEL TO SHEAR / PERPENDICULAR TO CLOSEST EDGE) ANc = SIDE^ * SIDEll =63.00 in2 (PROJECTED FAILURE SURFACE AREA ACI-318 17.4.2.1) ANc0 = n*9*(hef')2 =72.00 in2 (PROJECTED FAILURE SURFACE AREA OF 1 ANCHOR, NO INFLUENCE 17.4.2.1) Yed,N = 0.7+0.3*Ca1/(1.5*hef') =1.00 (IF Ca1 ≥1.5hef THEN = 1.0) 0.55 (ALWAYS ≤ 1.0) 3253.31 lbs N/A (MORE THAN ONE ANCHOR) (VALUES ARE IN POUNDS) 1552.71 1009.26 lbs ¬ DESIGN CONRETE BREAKOUT TENSION STRENGTH CHECK SIDE-FACE BLOWOUT Abrg =0.051 in2 (BEARING AREA OF CONCRETE AT ANCHOR BOTTOM. USE Ase FROM TABLES 4 & 5 OF ESR) CHECK EDGE DISTANCE → Ca1 < 0.4hef →3 > 0.8 FOR SINGLE ANCHORS - CHECK Ca2 → Ca2 < 3Ca1 →3 < 9 REDUCTION FACTOR FROM Ca2 =0.5 → WHERE 1.0 £ Ca2/Ca1 £ 3.0 →TRUE! 5937.27 lbs → REDUCED VALUE =2968.6 lbs (ACI 318, 17.4.4.1) FOR MULTIPLE ANCHORS (GROUPS) - CHECK BOLT SPACING → S < 6Ca1 →4.5 < 18 3710.8 lbs (ACI-318 17.4.4.2) FcNNsb < FcNNcb →2412.0 lbs SIDE FACE BLOWOUT VALUE JOB NAME: SANTA ANA MEMORIAL PARK AQUATICS CENTER M. W. SAUSSE' & CO., INC. CUST.: WEST-TECH MECHANICAL PREPARED BY : MECH. ENG.: DATE : MARK: CU-1-1, 1-2 SHEET NO. : HILTI KB-TZ2 CARBON AND STAINLESS STEEL ANCHORS IN CONCRETE (U.S. CUSTOMARY UNITS, ESR-4266 (REISSUED DECEMBER 2021) AND ACI-318-14, CH. 17) JA 18-Nov-24 P26681-S8076-C3.2A == ac efa1 Ncp,C ;1.5hCmaxΨ ==1.5 efccbh*f'*k*N λ = == == cbcN bNcp,Nc,Ned,Nec, Nc0 Nc cb bNcp,Nc,Ned, Nc0 Nc cb NΦ NΨΨΨΨ A AN NΨΨΨ A AN =='fACN cbrga1sb160*l =+ 4 1 1 2 a a C C =     +=sb a1 sbg N 6C S1N 3/4/2025 PULLOUT STRENGTH Np =0 lbs (ESR, TABLES 4 & 5) n = ncr or nuncr =0.00 FcN*l*Npn,f'c = N/A lbs (ANCHOR PULLOUT STRENGTH, 4.1.4 OF ESR) SHEAR BREAKOUT STRENGTH da =0.375 in (OUTSIDE DIAMETER OF ANCHOR BOLT OR ROD) Ca1 =3 in (USE AT LEAST Ca,min GIVEN IN TABLE 3 & 6 IN ESR, INCREASE IF NECESSARY) Ca2 =3 in (USE AT LEAST Ca,min & ³ Ca1 GIVEN IN TABLE 3 & 6 IN ESR, INCREASE IF NECESSARY) le = 2 in (MIN( hef OR 8da); ACI-318 SECTION 17.5.2.2) Yec,V =1 (ACI D.5.2.4; 1.0 WHEN NO LOAD ECCENTRICITY) ha =4 in (THICKNESS OF CONCRETE MEMBER) FcV =0.70 (SHEAR CONCRETE BREAKOUT STRENGTH REDUCTION; ESR TABLES 4 & 5) kcp =1 (PRYOUT COEFFICIENT, ESR, TABLE 6) Yc,V = 1.2 (1.0 FOR CONC. W/O REINFORCEMENT, 1.2 FOR CONC. W/ REINFORCEMENT, 1.4 SEE 17.5.2.7) Ca1' =3 in (Ca1 ADJUSTED WHEN Ca2 & Ca4 ARE LESS THAN 1.5Ca1, 17.5.2.4) nV =2 (NO. OF ANCHORS IN ROW CLOSEST TO CONCRETE EDGE) Yed,V = 0.7+0.3*Ca2/(1.5*Ca1') =0.90 (IF Ca2 ³ 1.5Ca1 THEN = 1.0, ACI 318 17.5.2.6) Yh,V = [(1.5*Ca1') / ha]0.5 =1.06 (ALWAYS GREATER THAN OR EQUAL TO 1.0, 17.5.2.8) AVc = min(ha;1.5Ca1')*(min(1.5Ca1',Ca4)+S2+min(Ca2;1.5Ca1') =48.0 in2 (REFER TO ACI-318 17.5.2.1) AVc = nV4.5Ca1'2=81.0 in2 (REFER TO ACI-318 17.5.2.1) 1705.12 OR Vb = 9la(fc')1/2 * ca1 1.5 =2561.4 Vb =1705.1 lbs N/A (MORE THAN ONE ANCHOR) (VALUES ARE IN POUNDS) 1157.48 FcVVcb =810.234 lbs ¬ DESIGN SHEAR CONRETE STRENGTH PRYOUT STRENGTH FROM SHEAR (ACI-318 SECTION 17.5.3.1) Vcp = kcp*FcNNcb =1009.26 lbs ¬ DESIGN PRYOUT (DUE TO SHEAR) STRENGTH CONTROLLING STRENGTH FOR ANCHORAGE TENSILE STRENGTH - STEEL =4635 lbs CONCRETE = 1009.3 lbs <= CONTROLLING STRENGTH Nd PULLOUT =N/A lbs SIDE FACE BLOWOUT =2412.0 lbs SHEAR STRENGTH - STEEL =3175.25 lbs CONCRETE = 810.234 lbs <= CONTROLLING STRENGTH Vd PRYOUT FROM SHEAR =1009.26 lbs ASD ADJUSTMENT FACTORS AND DESIGN LOADS INPUT… a =1.00 (ASD CONVERSION FACTOR IF APPLICABLE) SEISMIC TENSION FACTOR (FSEISMIC) =0.75 (PER SECTION 17.2.3.4.4, REDUCE TO 0.75 FOR SEISMIC DESIGN TENSION FOR CONCRETE FAILURE MODES) Ncap = FSEISMICF Nn/a =757 lbs Vcap =F Vn/a =810 lbs ANCHORAGE SUMMARY: ENTER GIVEN BOLT FORCES FROM PAGE:P26681-S8076-C3.1A 3/8 in DIAMETER Nua =262.15 lbs STAINLESS STEEL HILTI KB-TZ2 ANCHORS, Vua =93.02 lbs 2.5 in NOMINAL EMBEDMENT, 3 in MIN. EDGE DISTANCE, CHECK COMBINED LOADING (ESR SECTION 4.2)4 in MIN. CONCRETE THICKNESS 3000 psi NORMALWEIGHT CONCRETE. 0.46 ≤ 1.2 OK!INSTALL W/ SPECIAL INSPECTION PER THE ICC ESR-4266. JOB NAME: SANTA ANA MEMORIAL PARK AQUATICS CENTER M. W. SAUSSE' & CO., INC. CUST.: WEST-TECH MECHANICAL PREPARED BY : MECH. ENG.: DATE : MARK: CU-1-1, 1-2 SHEET NO. : 18-Nov-24 P26681-S8076-C3.3A INPUT HERE JA == == =     = bVc,Ved,Vec, Vc0 Vc cb bVc,Ved, Vc0 Vc cb 1.5 a1c0 0.2 0 e b V A AV V A AV )'(Cf'd d 7*V Vh, Vh, ΨΨΨΨ ΨΨΨ λ l =+ cap ua cap ua V V N N ΦcNN f′ 2500 3/4/2025 CALCULATE HORIZONTAL WIND FORCE (F IN LBS., DIMS. IN FT): EXPOSURE CATEGORY: C BUILDING HEIGHT (hr):30 VELOCITY EXPOSURE FACTOR (KZ) (TABLE 26.10-1): 0.98 TOPOGRAPHIC FACTOR KZT = (1+K1K2K3)2 (EQ. 26.8-1) K1,K2 AND K3 FROM (FIGURE 26.8-1): K1 =0 K2 =0 K3 =0 KZT =1 Kd (DIRECTIONALITY FACTOR, TABLE 26.10-1) =0.90 OCCUPANCY/RISK CATEGORY =III *(FOR WIND SPEED MAP SELECTION - SEE FIG. 26.5-1A TO 1C) WIND VELOCITY (V IN MPH) =95 20.4 HORIZONTAL LOAD: (GCr) =1.9 (REDUCEABLE, SEE SECTION 29.4.1) Af =10.02 ft2 (VERTICAL FACE OF EQUIPMENT NORMAL TO HORIZ. WIND PRESSURE) (29.4-2) Fh = qh(GCr)Af =387.9835 lbs VERTICAL LOAD: (GCr) =1.5 (REDUCEABLE, SEE SECTION 29.4.1) Ar =3.24 ft2 (HORIZONTAL FACE OF EQUIPMENT NORMAL TO VERT. WIND PRESSURE) (29.4-3) Fv = qh(GCr)Ar =99.15569 lbs DESIGN LOADS FOR ANCHORAGE CALCULATIONS Fh = 387.98 lbs Fv =99.156 lbs JOB NAME: SANTA ANA MEMORIAL PARK AQUATICS CENTER M. W. SAUSSE' & CO., INC. CUST.: WEST-TECH MECHANICAL PREPARED BY: MECH. ENGR.: DATE : MARK: CU- 2, 3, 4, 5, 6, 7, 8, 9 (RES)SHEET NO.: 12/10/2025 P26681-S8076-C10 CALCULATIONS FOR RIGID ANCHORAGE - WIND LOADING (ASCE 7-16) FIND VELOCITY PRESSURE (qh) = 0.00256*KZ*KZT*Kd*V2 (LBS/FT2) IF GROUND IS FLAT ENTER THE VALUE OF ZERO FOR ALL VELOCITY PRESSURE (qh) = HORIZONTAL AND VERTICAL WIND LOADS FROM SECTION 29.4.1 PDG 12/10/2025 27 BY DATE 12/20/2025 These documents (drawings, specifications, or calculations) have been prepared by other design professionals or consultants who are licensed and/or authorized to prepare such documents in California. These documents have been examined by JAMA for design intent and have been found to meet the appropriate structural requirements and the project specifications. JOHN A. MARTIN & ASSOCIATES, INC. STRUCTURAL ENGINEERS 950 S. Grand Ave., Fourth Floor, Los Angeles, CA 90015 Deferred Approval rlawrence BY DATE 12/20/2025 Reviewed for design loads only as they affect the primary structure. Not responsible for design, dimensions or quality of material JOHN A. MARTIN & ASSOCIATES, INC. STRUCTURAL ENGINEERS 950 S. Grand Ave., Fourth Floor, Los Angeles, CA 90015 Design Load Review rlawrence CALCULATIONS FOR RIGID ATTACHMENT TO STEEL W/ BOLTS; 2021 IBC/2022 CBC & ASCE 7-16, LRFD CALCULATES WORST CASE LOADING FOR (4) TO (14) ATTACHMENT POINTS. (UNITS: LBS & INCHES) USING COMBINED LOAD EQUATIONS 16-4, 16-5, 16-6, & 16-7 SEISMIC/WIND FORCES - CH. 13, 26, & 29 OF ASCE 7 13.3-1: Fp=(0.4*ap*Sds/(Rp/Ip))(1+2z/hr)Wp = 257.10 lbs 13.3-2: Fp=1.6*Sds*Ip*Wp (MAX)= 274.24 lbs 13.3-3: Fp=0.3*Sds*Ip*Wp (MIN)= 51.42 lbs CONTROLLING HOR. SEISMIC FORCE: F p = 257.10 lbs SEISMIC OVERTURNING MOMENT: M=F ph*HC.G.= 5167.07 lb-in VERTICAL SEISMIC FORCE: F pv = 0.2SdsWp = 34.28 lbs SPECTRAL RESP. ACCEL'N: S ds = 0.857 IMPORTANCE FACTOR: I p = 1.00 COMPONENT AMPLIFICATION FACTOR: a p = 2.50 COMP. RESPONSE MODIFICATION FACTOR: R p = 2.00 EQUIPMENT ELEVATION / ROOF ELEVATION: z/h r = 1.00 (WITH RESPECT TO GRADE) UNIT LOCATED INDOORS OR OUTDOORS = OUTDOORS Fh FROM PREVOUS CALCULATION (IF APPLICABLE)= 387.98 lbs Fv FROM PREVOUS CALCULATION (IF APPLICABLE)= 99.16 lbs WIND OVERTURNING MOMENT: M w = FpHw = 8171.90 lb-in EQUIPMENT WEIGHT & GEOMETRY EQUIPMENT WEIGHT: Wp (UNIT + RMU) = 200.00 lbs L:= 12.22 in B: = 6.88 in EX:= 1.22 in EZ:= 0.69 in HEIGHT TO CG.: HC.G.= 20.10 in CNTR OF AREA OF WINDWARD FACE: H W = 21.06 in NO. OF FASTENER GROUPS (Ng) = 4.00 NO. OF FASTENERS PER GROUP (N) = 1.00 MOMENT OF INERTIA ABOUT X AXIS: I X = 189.06 in4 α (DIR. OF Vdir-CRIT. ANGLE): tan-1(EZ/EX)= 29.36 MOMENT OF INERTIA ABOUT Z AXIS: I Z = 597.19 in4 β: γ - α == 180.00 γ (DIR. OF Vrot-CRIT. ANGLE): tan-1(B/L)= 29.36 θ (DIR. OF Fph FOR MAX UPLIFT): tan-1((L*IX)/(B*IZ))= 29.36 BOLT GROUP FORCES FROM SEISMIC LOADS (LOAD APPLIED TO CRITICAL ANGLE)FROM WIND LOADS (LOAD PERPENDICULAR TO UNIT LENGTH) VERTICAL REACTIONS (WITH 1.2D OR 0.9D):VERTICAL REACTIONS (WITH 1.2D OR 0.9D): Rm (DUE TO OVERTURNING MOMENT)= 215.59 lbs Rm (DUE TO OVERTURNING MOMENT)= 297 lbs Re MAX (DUE TO ECCENTRICITY):= 13.71 lbs Re MAX (DUE TO ECCENTRICITY):= 12.00 lbs Re MIN (DUE TO ECCENTRICITY): = 7.29 lbs Re MIN (DUE TO ECCENTRICITY): = 9 lbs Rv MAX (DUE TO VERTICAL LOADS): = 68.57 lbs Rv MAX (DUE TO VERTICAL LOADS): = 35.21 lbs Rv MIN (DUE TO VERTICAL LOADS): = 36.43 lbs Rv MIN (DUE TO VERTICAL LOADS): = 20.21 lbs PMAX (MAX DOWNWARD REACTION): R m+Re MAX+Rv MAX = 297.88 lbs PMAX : Rm+Re MAX+Rv MAX = 344.4 lbs PMIN (MAX UPLIFT/ANCH. POINT - IF POS.): R m+Re MIN -Rv MIN =186.45 lbs PMIN : R m+Re MIN -Rv MIN (0 IF NEGATIVE)=285.9 lbs HORIZONTAL REACTIONS:HORIZONTAL REACTION: Vrot (SHEAR DUE TO ECCENTRICITY):= 6.43 lbs VMAX = V dir =97.00 lbs Vdir (DIRECT SHEAR): = 64.28 lbs VMAX (TOTAL SHEAR/ANCH. POINT):=70.70 lbs WIND LOAD(S) GOVERN(S) THE DESIGN OF THE BOLTS!! BOLT TENSION: T u = P MIN/N =285.95 lbs BOLT SHEAR: V u = V MAX/N =97.00 lbs BOLT DIAMETER:=3/8 JOB NAME: SANTA ANA MEMORIAL PARK AQUATICS CENTER M.W. SAUSSE' & CO., INC. CUST.: WEST-TECH MECHANICAL PREPARED BY : MECH. ENGR.: DATE : MARK: CU- 2, 3, 4, 5, 6, 7, 8, 9 (RES) SHEET NO. : TYPE OF BOLT: A307 Gr. A HEX BOLTS WITH A563 HEAVY NUTS. PDG 10-Dec-25 P26681-S8076-C10.1 12/10/2025 27 BOLT PROPERTIES FOR A307 Gr. A HEX BOLTS D =0.375 in Fu =60.00 ksi (ULTIMATE TENSILE STRENGTH) SHEAR PLANE THRU THREADS?YES *SEE (C-J3-3 & C-J3-4 FOR CALCULATION OF SHEAR STRESS BELOW) BOLT CAPACITY Ab =0.110 in2 Fnt =45.0 ksi Fnv =27.0 ksi φ =0.75 SHEAR STRESS FOR COMBINED LOADING Vu =0.10 kips frv = Vu/Ab =0.88 ksi COMBINED LOADING PER J3.7 OF AISC 360-16 PER EQUATION J3-2: Tu =0.29 kips φRn = 0.75F'ntAb ≥ Tu MIN[F'nt = 1.3Fnt - (Fnt/φFnv)frv ; Fnt] =45.00 ksi φRn = 0.75F'ntAb =3.73 kips > Tu BOLT/STUD OKAY! JOB NAME: SANTA ANA MEMORIAL PARK AQUATICS CENTER M. W. SAUSSE' & CO., INC. CUST.: WEST-TECH MECHANICAL PREPARED BY : MECH. ENGR.: DATE : MARK: CU- 2, 3, 4, 5, 6, 7, 8, 9 (RES)SHEET NO. : SPECIALIZED STEEL BOLT STRENGTH DESIGN - LRFD - AISC 360-16 USE 3/8" DIA. A307 GR. A HEX BOLT W/ NUT & WASHER PDG 10-Dec-25 P26681-S8076-C10.2 12/10/2025 27 RIGID ANCHORAGE OF CONDENSER END RAIL SUPPORT FROM CALCULATION SHEET NO.P26681-S8076-C10.1 TOTAL SHEAR PER RES: V MAX* 2 =193.99 lbs MAX. UPLIFT PER RES : P MIN.*2 =571.90 lbs CHECK FOR ANCHORAGE OF THE PEDESTAL BOLT SPACING : S =7 in RES HEIGHT H1:=16.00 in H2: = H1/2 =8.00 in WEIGHT PER RES: WT =37 lbs NUMBER OF BOLTS PER RES: Nb =12 DUE TO P MIN. T1 = P MIN. / Nb =47.66 lbs DUE TO V MAX: T2 = V MAX. * H/(S/*Nb/2)=73.90 lbs DUE TO RES WT. T3 = RES WT. / Nb =3.08 lbs T4= RES WT. /H2/(S*Nb/2)=0.11 lbs SHEAR PER BOLT DUE TO UNIT: V1 (V MAX/Nb)=16.17 lbs SHEAR PER BOLT DUE TO RES: V2 (RES WT. /Nb)=3.08 lbs TOTAL TENSION PER BOLT: Tab =(T1+T2-T3+T4)=118.59 lbs TOTAL SHEAR PER BOLT: Vab =(V1+V2)=19.25 lbs TRY NO. 1/4-14 TEKS SCREW INTO 20 GA. METAL (LRFD VALUES) Tall = 172.50 lbs Vall = 322.50 lbs CHECK COMBINED LOADING: Tab/Tall + Vab/Vall =<1.0 0.75 OKAY JOB NAME: SANTA ANA MEMORIAL PARK AQUATICS CENTER M. W. SAUSSE' & CO., INC. CUST.: WEST-TECH MECHANICAL PREPARED BY::PDG MECH. ENGR.: DATE::10-Dec-25 MARK: CU- 2, 3, 4, 5, 6, 7, 8, 9 (RES) SHEET NO.::P26681-S8076-C10.3 12/10/2025 27 321 A B C D E F G H J L CU 2 CU 9 CU 8 CU 7 CU 6 CU 5 CU 4 CU 3 10 ' - 0 " 1 EF 3 EF 2 PLAN NORTH LVR 2 PROVIDE ROOF CURB FOR OA DUCTWORK, REFER TO 8/M401 PROVIDE ROOF CURB FOR EF-2 AND EF-3, REFER TO 1/M402 16"ø OA LVR 1 ARCHITECT: ELS ARCHITECTURE AND URBAN DESIGN 2040 Addison Street Berkeley, CA 94704 P: 510.549.2929 CIVIL ENGINEER: KPFF 700 South Flower Street, Suite 2100 Los Angeles, CA 90017 P: 213.418.0201 LANDSCAPE ARCHITECT: SWA 570 Glenneyre Street Laguna Beach, CA 92651 P: 949.497.5471 STRUCTURAL ENGINEER: JOHN A. MARTIN & ASSOCIATES 950 South Grand Avenue, 4th Floor Los Angeles, CA 90015 P: 213.483.6490 MECHANICAL & ELECTRICAL ENGINEER: GUTTMANN & BLAEVOET 1620 Montgomery Street, Suite 230 San Francisco, CA 94111 P: 415.655.4000 AQUATICS: AQUATIC DESIGN GROUP 2226 Faraday Avenue Carlsbad, CA 92008 P: 760.438.8400 SPECIFICATIONS: SPECWEST 1975 E. Buck Ridge Pl Tucson, AZ 85737 P: 800.646.3820 SHEET NUMBER: PROJECT NUMBER: DATE: ISSUE: SHEET TITLE: PROJECT: CLIENT: PROJECT TEAM: STAMP: GENERAL NOTES SHEET NOTES CONFORMED SET ROOF PLAN - HVAC M250 JANUARY 10, 2025 CITY OF SANTA ANA 20 CIVIC CENTER PLAZA, SANTA ANA, CA 92701 SANTA ANA MEMORIAL PARK AQUATICS CENTER 2102 S FLOWER ST SANTA ANA, CA 92707 202305 1/8" = 1'-0"1 ROOF PLAN - HVAC 1 PROVIDE ALUMINUM JACKETING FOR THE REFRIGERANT PIPING INSULATION EXPOSED TO OUTDOORS, SEE SPECIFICATIONS. 2 ANY EXHAUST DISCHARGE OR PLUMBING VENT SHALL BE MINIMUM 10 FEET DISTANCE TO ANY AC UNIT INTAKE. 3 PROVIDE CONDENSING UNITS WITH GUARD RAILS. 4 MAINTAIN MINIMUM 10 FEET IN BETWEEN AC UNIT EXHAUST DISCHARGE AND OUTSIDE AIR INTAKE BY EXTENDING EXHAUST DUCT. 5 EQUIPMENT SERVICE CLEARANCE SHOWN DASHED REVISION NUMBER DATE DESCRIPTION T1 TA TB TC T2 CHEM 1 VFD 2 VFD 1 8" HS ICW MAKE-UP WATER CONNECTION, SEE 2/P0.10, 1/P6.01 8" HR VFD 3 ET 1 AS 1 8" HR BT 1 HP 2-1 HP 2-2 HP 2-3 HP 2-4 HP 2-5 HP 2-6 HP 1-6 HP 1-5 HP 1-4 HP 1-3 HP 1-2 HP 1-1 PHP 2 PHP 1 SERVICE CLEARANCE, TYP. PHWP 1 PHWP 2 PHWP 3 FOR CONTINUATION, SEE 3/M301 EQ EQ 1 A D12 1 A CU 1-1 UNDERGROUND REFRIGERANT PIPING(RL, RS, SEE M103 AND M702 FOR PIPE SIZING AND DIAGRAM) CU 1-2 UNDERGROUND REFRIGERANT PIPING(RL, RS, SEE M103 AND M702 FOR PIPE SIZING AND DIAGRAM) FOR CONTINUATION, SEE M103 321 L T2 T3 DB DC 321 J (N) 8" HS (N) 8" HR FOR CONTINUATION, SEE M202 FOR CONTINUATION, SEE 1/M301 ARCHITECT: ELS ARCHITECTURE AND URBAN DESIGN 2040 Addison Street Berkeley, CA 94704 P: 510.549.2929 CIVIL ENGINEER: KPFF 700 South Flower Street, Suite 2100 Los Angeles, CA 90017 P: 213.418.0201 LANDSCAPE ARCHITECT: SWA 570 Glenneyre Street Laguna Beach, CA 92651 P: 949.497.5471 STRUCTURAL ENGINEER: JOHN A. MARTIN & ASSOCIATES 950 South Grand Avenue, 4th Floor Los Angeles, CA 90015 P: 213.483.6490 MECHANICAL & ELECTRICAL ENGINEER: GUTTMANN & BLAEVOET 1620 Montgomery Street, Suite 230 San Francisco, CA 94111 P: 415.655.4000 AQUATICS: AQUATIC DESIGN GROUP 2226 Faraday Avenue Carlsbad, CA 92008 P: 760.438.8400 SPECIFICATIONS: SPECWEST 1975 E. Buck Ridge Pl Tucson, AZ 85737 P: 800.646.3820 SHEET NUMBER: PROJECT NUMBER: DATE: ISSUE: SHEET TITLE: PROJECT: CLIENT: PROJECT TEAM: STAMP: CONFORMED SET SECTIONS & ENLARGED PLANS M301 JANUARY 10, 2025 CITY OF SANTA ANA 20 CIVIC CENTER PLAZA, SANTA ANA, CA 92701 SANTA ANA MEMORIAL PARK AQUATICS CENTER 2102 S FLOWER ST SANTA ANA, CA 92707 202305 1/4" = 1'-0"1 YARD PLAN - HYDRONIC PIPING 1/4" = 1'-0"2 WET POOL STORAGE AREA - HVAC 1/8" = 1'-0"3 UNDERGROUND HEATING HOT WATER PIPING REVISION NUMBER DATE DESCRIPTION 2 8/21/24 ADDENDUM 3 2 321 A B C D E F G H J W1 0 x 1 2 W1 0 x 1 2 W1 0 x 1 2 W1 0 x 1 2 W1 0 x 1 2 RD-2 RD-2 W 1 0 x 1 2 W 1 0 x 1 2 W 1 0 x 1 2 W 1 0 x 1 2 W 1 0 x 1 2 HSS8x8x5/8 T-1 BOT CHORD W12x26 BELOW BELOW 48"x16" CMU BM W12x26 T-1 BOT CHORD T-1 BOT CHORD T-1 BOT CHORD T-1 BOT CHORD T-2 BOT CHORD 0 " 0 " HSS8x8x5/8 W10x12 W10x12 L MC 8 x 2 0 M C 8 x 2 0 M C 8 x 2 0 MC 8 x 2 0 M C 8 x 2 0 M C 8 x 2 0 MC 8 x 2 0 M C 8 x 2 0 M C 8 x 2 0 MC 8 x 2 0 M C 8 x 2 0 M C 8 x 2 0 TYP 0" W 8 x 1 0 M C 8 x 2 0 M C 8 x 2 0 W 8 x 1 8 W 8 x 1 8 MC 8 x 2 0 M C 8 x 2 0 MC 8 x 2 0 MC 8 x 2 0 (T O S E L = 1 0 ' - 0 " ) S501 1 TYP 4 S501 TYP 5 S501 TYP 4 S501 SIM 7 S501 OH S501 8 5/8"Ø ROD 5/8"Ø ROD 5/8"Ø ROD 5/8"Ø ROD 5 S501 TYP 16" SQ BOND BEAM16" SQ BOND BEAM W 8 x 1 8 W 8 x 1 8 W 8 x 1 8 W 8 x 1 8 W8 x 1 8 W 8 x 1 8 W 8 x 1 8 W 8 x 1 8 W8 x 1 8 W8 x 1 8 13 S501 FC - 1 - 1 ER V - 2 FC - 3 FC-4 ERV-1 EF-1 CU-7 CU-6CU-8CU-9 CU-5 CU-4 CU-3 CU-2 14 S501 14 S501 SIM 15 S501 17 S501 W 1 0 x 1 2 HS S 6 x 6 x 3 / 8 MAX 1' - 0" W8x28 HOIST BEAM BELOW W10x12 W10x12 16 S321 18 S321 2 S502 3 S502 15 S103 2 12 S502 TYP 12 S502 TYP 13 S502 13 S502 OPP 16 " S Q B O N D BE A M 16 " S Q B O N D BE A M 14 S502 SIM 14 S502 S502 15 S502 17 TYP @ LINES E & J TYP @ LINES E & J 3 3 3 3 3 3 3 3 3 3 321 A B C D E F G H J 11 S321 T-2 T-1 T-1 T-1 T-1 T-1 HS S 8 x 6 x 3 / 8 HS S 8 x 6 x 3 / 8 H S S 8 x 6 x 3 / 8 H S S 8 x 6 x 1 / 2 HS S 8 x 6 x 3 / 8 HS S 8 x 6 x 3 / 8 HS S 8 x 6 x 3 / 8 W 8 x 1 8 HS S 8 x 6 x 3 / 8 H S S 8 x 6 x 3 / 8 HS S 8 x 6 x 3 / 8 HS S 8 x 6 x 3 / 8 HS S 8 x 6 x 3 / 8 H S S 8 x 6 x 3 / 8 H S S 8 x 6 x 3 / 8 HS S 8 x 6 x 3 / 8 H S S 8 x 6 x 3 / 8 HS S 8 x 6 x 3 / 8 H S S 8 x 6 x 3 / 8 HS S 8 x 6 x 3 / 8 HS S 8 x 6 x 3 / 8 H S S 8 x 6 x 3 / 8 RD-1 RD-1 RD-1 RD-1 RD-1 RD-1 TYP UNO L BEAM BELOW W 8 x 1 0 W 8 x 1 0 W 8 x 1 8 W 8 x 1 0 W 8 x 1 0 W 8 x 1 0 W 8 x 1 0 HS S 8 x 6 x 3 / 8 W 8 x 1 0 W 8 x 1 0 W 8 x 1 0 W 8 x 1 0 W 8 x 1 0 W 8 x 1 0 1 S321 6 S321 W 8 x 1 8 W 8 x 1 8 W 8 x 1 8 W 8 x 1 8 W 8 x 1 8 W 8 x 1 8 W 8 x 1 8 W8 x 1 8 W8 x 1 8 W 8 x 1 8 HS S 8 x 6 x 3 / 8 HS S 8 x 6 x 3 / 8 HSS8x2x1/4, TYP 13 S321 HS S 8 x 6 x 3 / 8 HS S 8 x 6 x 3 / 8 HS S 8 x 6 x 3 / 8 HS S 8 x 6 x 1 / 2 HS S 8 x 6 x 1 / 2 HS S 8 x 6 x 1 / 2 HS S 8 x 6 x 1 / 2 HS S 8 x 6 x 1 / 2 HS S 8 x 6 x 1 / 2 HS S 8 x 6 x 1 / 2 HS S 8 x 6 x 1 / 2 HS S 8 x 6 x 1 / 2 HS S 8 x 6 x 1 / 2 HS S 8 x 6 x 1 / 2 HSS8x8x1/4, TYP 16 S321 18 S321 HSS8x6x3/8 W8x24 W8x24 W8x18 HSS8x6x3/8 HSS8x6x3/8 19 S501 TYP 20 S501 TYP W8x24 20 S501 TYP HSS8x6x3/8W8x24 PLAN LEGEND: PLAN NOTES: 1. VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAW INGS. 2. FOR GENERAL NOTES AND TYPICAL DETAILS, SEE SHEETS S001 THRU S105. 3. BEAMS SHALL BE EQUALLY SPACED ACROSS Wx GIRDER, UNLESS SHOWN OR NOTED OTHERWISE ON PLAN INDICATES BROKEN BEAM. RD-1 INDICATES VERCO PLB-36x16 GA GALVANIZED METAL ROOF DECK (OR APPROVED EQUAL) SUPPORT ATTACHMENT: 4-1/2"Ø EFF ARC SPOT WELDS PER SHEET PER PERPENDICULAR / SKEWED SUPPORT AND 12" AT PARALLEL SUPPORTS AND MARGINS SIDELAP CONNECTION: VSC2 @12" INDICATES ROOFTOP MECHANICAL EQUIPMENT PER 4/S105 INDICATES SUSPENDED MECHANICAL EQUIPMENT MECH EQUIP MARK MECH EQUIP WEIGHT CU-2 Pmax = 100 lbs CU-3 Pmax = 180 lbs Pmax = 180 lbsCU-4 Pmax = 180 lbsCU-5 Pmax = 100 lbsCU-6 Pmax = 100 lbsCU-7 Pmax = 110 lbsCU-8 Pmax = 100 lbsCU-9 Pmax = 100 lbsEF-1 Pmax = 530 lbsFC-1-1-1 Pmax = 110 lbsFC-3 Pmax = 110 lbsFC-4 Pmax = 460 lbsERV-1 Pmax = 1170 lbsERV-2 INDICATES TIE-BACK ANCHOR GN N ER E I LJLEA ANSIO ARDTE ER GIS EDR CH RP EOF No. S4327 S IAAL OFALI UR NR TS FEO R U CTS AT T C WREN DATE SIGNED: 01/10/25 CE IR L O S A N G E L E S + O A K L A N D STRUCTURAL ENGINEERS A S S O C I A T E S JOHN A. MARTIN JOB : ARCHITECT: ELS ARCHITECTURE AND URBAN DESIGN 2040 Addison Street Berkeley, CA 94704 P: 510.549.2929 CIVIL ENGINEER: KPFF 700 South Flower Street, Suite 2100 Los Angeles, CA 90017 P: 213.418.0201 LANDSCAPE ARCHITECT: SWA 570 Glenneyre Street Laguna Beach, CA 92651 P: 949.497.5471 STRUCTURAL ENGINEER: JOHN A. MARTIN & ASSOCIATES 950 South Grand Avenue, 4th Floor Los Angeles, CA 90015 P: 213.483.6490 MECHANICAL & ELECTRICAL ENGINEER: GUTTMANN & BLAEVOET 1620 Montgomery Street, Suite 230 San Francisco, CA 94111 P: 415.655.4000 AQUATICS: AQUATIC DESIGN GROUP 2226 Faraday Avenue Carlsbad, CA 92008 P: 760.438.8400 SPECIFICATIONS: SPECWEST 1975 E. Buck Ridge Pl Tucson, AZ 85737 P: 800.646.3820 SHEET NUMBER: PROJECT NUMBER: DATE: ISSUE: SHEET TITLE: PROJECT: CLIENT: PROJECT TEAM: STAMP: J23245 CONFORMED SET ROOF FRAMING PLANS S202 JANUARY 10, 2025 CITY OF SANTA ANA 20 CIVIC CENTER PLAZA, SANTA ANA, CA 92701 SANTA ANA MEMORIAL PARK AQUATICS CENTER 2102 S FLOWER ST, SANTA ANA, CA 92707 202305 1/8" = 1'-0" ALOWER FRAMING PLAN 1/8" = 1'-0" BUPPER FRAMING PLAN REVISION NUMBER DATE DESCRIPTION 2 8/21/24 ADDENDUM 3 3 01/10/25 CONFORMED SET MEMORANDUM To: Date: From: Subject:No fee Building Plan Check & Permit for Project 22-1415 Memorial Park Aquatics Center (City Project) The Public Works Agency is managing the design and construction process for a New Aquatics Center & Two Pools at Memorial Park, 2102 Flower Street. The project will require a several building permit(s) for demolition, grading, building, mechanical, electrical, plumbing, sign & solar. As this is a City project, we are requesting few waivers for all applicable PBA plan checking & permits. The Scope of Work includes renovation of an existing City of Santa Ana Memorial Park Aquatics Center, including demolition of a non-conforming structure, demolition of an existing pool, grading, new building, 2 new pools (recreational & competition), pool deck with seating areas, ADA compliancy, exterior lighting, cameras, lighting fixtures, landscape, irrigation, site furnishings, exterior fencing & concrete. If there are any questions, please contact Victor Rosales at Extension #5686 (office), or 714-904- 8950.