Loading...
HomeMy WebLinkAbout2621 & 2621 3%4 S Birch St - PlanSHEET NO. DESCRIPTIONSHEET NO. DESCRIPTION T-1 TITLE SHEET GN-1 GENERAL NOTES A-1 SITE PLAN A-2 EQUIPMENT LAYOUTS A-3.1 EXISTING ANTENNA PLAN A-3.2 NEW ANTENNA PLAN A-4 ELEVATIONS A-5 ELEVATIONS D-1 DETAILS G-1 GROUNDING PLAN G-2 GROUNDING DETAILS APPROVED APPROVED AS NOTED REVISE & RESUBMIT OWNER REPRESENTATIVE DATE SITE ACQUISITION DATE CONSTRUCTION MANAGER DATE ZONING DATE RF ENGINEER DATE APPROVAL BLOCK TITLE SHEET mobility corp. mobility corp. SHEET TITLE SHEET NUMBER DRAWN BY: CHECKED BY: - JS 1452 EDINGER AVE. TUSTIN, CA 92780 PROJECT NO: AT&T SITE NO:CLL03413 10086996 90% CD'S FOR REVIEW EXPIRATION DATE: 06/30/2027 APPLICANT: CLL03413 MAIN / DYER 2621 & 2621 3/4 SOUTH BIRCH STREET SANTA ANA, CA 92707 JS03/17/2025A ENGINEER: T-1 PLANS PREPARED BY: DATE SIGNED: 12/11/2025 95% CD'S - CLIENT RLs RDL05/01/2025B 100% CD'S FOR SUBMITTAL DS12/11/20250 SITE CALL CALIFORNIA ONE CALL (800) 422-4133 CALL 3 WORKING DAYS BEFORE YOU DIG! SITE INFORMATION SITE ADDRESS: 2621 & 2621 3/4 SOUTH BIRCH STREET SANTA ANA, CA 92707 LATITUDE (NAD 83):33.711732 33°42'42.2" N LONGITUDE (NAD 83):-117.869806 117°52'11.3" W GROUND ELEVATION:±49' AMSL JURISDICTION: CITY OF SANTA ANA PROPERTY OWNER: MICHAEL HOOD 2621 S. BIRCH ST SANTA ANA, CA 92707 TOWER OWNER: SBA 2012 TC ASSETS, LLC PARCEL/MAP NUMBER:410-391-03 STRUCTURE TYPE: MONOPOLE STRUCTURE HEIGHT: 60'-0" A.G.L. ZONING CLASSIFICATION:M-1 OCCUPANCY: UNMANNED TELECOM FACILITY CONSTRUCTION TYPE:II-B POWER SUPPLIER: SCE TELCO SUPPLIER:N/A PROJECT TEAM VICINITY MAP DIRECTIONS CODE COMPLIANCE ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THE LATEST EDITIONS OF THE FOLLOWING CODES. •2022 CALIFORNIA BUILDING CODE (CBC) •2022 CALIFORNIA TITLE 24, PART 10 •2022 CALIFORNIA FIRE CODE (CFC) •2022 CALIFORNIA ENERGY CODE •2022 CALIFORNIA ELECTRICAL CODE •2022 CALIFORNIA MECHANICAL CODE (CMC) •ANSI EIA/TIA-222-H •CITY/COUNTY ORDINANCES DIRECTIONS FROM AT&T OFFICE (1452 EDINGER AVE., TUSTIN, CA 92780): 1. HEAD SOUTHWEST TOWARD AT&T 279 FT 2. TURN RIGHT ONTO AT&T 0.1 MI 3. TURN LEFT ONTO EDINGER AVE 0.2 MI 4. TURN RIGHT ONTO RED HILL AVE 0.9 MI 5. TURN RIGHT ONTO WARNER AVE 2.0 MI 6. TURN LEFT ONTO S BIRCH ST 0.3 MI 7. DESTINATION WILL BE ON THE LEFT 377 FT DRAWING INDEX SCOPE OF WORK NE N E SESW W NW S DRAWING SCALE THESE DRAWINGS ARE SCALED TO FULL SIZE AT 22"x34" AND HALF SIZE AT 11"x17". CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONFITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE DESIGNER / ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR MATERIAL ORDERS OR BE RESPONSIBLE FOR THE SAME. CONTRACTOR SHALL USE BEST MANAGEMENT PRACTICE TO PREVENT STORM WATER POLLUTION DURING CONSTRUCTION. THIS PROJECT CONSISTS OF THE MODIFICATIONS OF AN EXISTING AT&T MOBILITY UNMANNED TELECOMMUNICATIONS FACILITY. THE SCOPE WILL CONSIST OF THE FOLLOWING: ANTENNA AREA: •REMOVE (3) AIR6449 B77D ANTENNAS •RELOCATE (1) TPA65R-BU6D ANTENNA FROM P1 TO P4 ON SECTOR A •RELOCATE (1) 80010965 ANTENNA FROM P3 TO P2 ON SECTOR A •RELOCATE (1) JAHH-65B-R3B-V3 ANTENNA FROM P4 TO P1 ON SECTOR A •INSTALL (3) AIR6472 B77G/B77M ANTENNAS •INSTALL (1) TPA65R-BU6D ANTENNA ON C1 •REMOVE ALL MDT BRACKETS EQUIPMENT AREA: •RE-USE (1) EXISTING NETSURE 7100 INDOOR POWER PLANT •REMOVE (1) 5216 BBU EXISTING ANTENNAS: 12 EXISTING RRUS: 15 REMOVED ANTENNAS: 4 REMOVED RRUS: 0 PROPOSED ANTENNAS: 4 PROPOSED RRUS: 0 TOTAL ANTENNAS: 12 TOTAL RRUS: 15 CLL03413 MAIN / DYER FA NUMBER: IWM ID: IWM SITE ID: USID: PACE NUMBER: 10086996 WSLOS0068683 SICA021242 26382 MRLOS115715 2621 & 2621 3/4 SOUTH BIRCH STREET SANTA ANA, CA 92707 APPLICANT: AT&T MOBILITY 1452 EDINGER AVE. TUSTIN, CA 92780 A/E: M SQUARED WIRELESS 1387 CALLE AVANZADO SAN CLEMENTE, CA 92673 CONTACT: JON MAXWELL PHONE: (949) 391-6824 PROJECT MANAGEMENT FIRM: ERICSSON TYLER KENT PHONE: (949) 701-2444 EMAIL: tyler.kent@ericsson.com RF ENGINEER: AT&T MOBILITY CONTACT: ATHAR ALI PHONE: (469) 534-2496 EMAIL: aa250e@att.com SITE ACQ MANAGER: M SQUARED WIRELESS FELICIA PHILLIPS PHONE: (714) 791-6643 EMAIL: felicia@msquaredwireless.com NOTE: NO NEW AC POWER WORK PROPOSED UNDER THIS PROJECT. mobility corp. SHEET TITLE SHEET NUMBER DRAWN BY: CHECKED BY: - JS 1452 EDINGER AVE. TUSTIN, CA 92780 PROJECT NO: AT&T SITE NO:CLL03413 10086996 90% CD'S FOR REVIEW EXPIRATION DATE: 06/30/2027 APPLICANT: CLL03413 MAIN / DYER 2621 & 2621 3/4 SOUTH BIRCH STREET SANTA ANA, CA 92707 JS03/17/2025A ENGINEER: GN-1 PLANS PREPARED BY: DATE SIGNED: 12/11/2025 95% CD'S - CLIENT RLs RDL05/01/2025B 100% CD'S FOR SUBMITTAL DS12/11/20250 GENERAL CONSTRUCTION NOTES: 1. FOR THE PURPOSE OF CONSTRUCTION DRAWINGS, THE FOLLOWING DEFINITIONS SHALL APPLY: GENERAL CONTRACTOR - GENERAL CONTRACTOR SUBCONTRACTOR - CONTRACTOR (CONSTRUCTION) OWNER - AT&T 2. ALL SITE WORK SHALL BE COMPLETED AS INDICATED ON THE DRAWINGS AND AT&T PROJECT SPECIFICATIONS. 3. GENERAL CONTRACTOR AND SUBCONTRACTOR SHALL VISIT THE SITE AND SHALL FAMILIARIZE HIMSELF WITH ALL CONDITIONS AFFECTING THE NEW WORK AND SHALL MAKE PROVISIONS. GENERAL CONTRACTOR AND SUBCONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH ALL CONTRACT DOCUMENTS, FIELD CONDITIONS, DIMENSIONS, AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. 4. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. GENERAL CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAT&T, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF WORK. 5. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES, AND APPLICABLE REGULATIONS. 6. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 7. PLANS ARE NOT TO BE SCALED. THESE PLANS ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY UNLESS OTHERWISE NOTED. DIMENSIONS SHOWN ARE TO FINISH SURFACES UNLESS OTHERWISE NOTED. SPACING BETWEEN EQUIPMENT IS THE MINIMUM REQUIRED CLEARANCE. THEREFORE, IT IS CRITICAL TO FIELD VERIFY DIMENSIONS, SHOULD THERE BE ANY QUESTIONS REGARDING THE CONTRACT DOCUMENTS, THE SUBCONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE ARCHITECT/ENGINEER PRIOR TO PROCEEDING WITH THE WORK. DETAILS ARE INTENDED TO SHOWN DESIGN INTENT. MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF WORK AND PREPARED BY THE ARCHITECT/ENGINEER PRIOR TO PROCEEDING WITH WORK. 8. THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 9. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS. THE SUBCONTRACTOR SHALL PROPOSE AN ALTERNATIVE SPACE FOR APPROVAL BY THE ARCHITECT/ENGINEER PRIOR TO PROCEEDING. 10. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF WORK AREA, ADJACENT AREAS AND BUILDING OCCUPANTS THAT ARE LIKELY TO BE AFFECTED BY THE WORK UNDER THIS CONTRACT. WORK SHALL CONFORM TO ALL OSHA REQUIREMENTS AND THE LOCAL JURISDICTION. 11. GENERAL CONTRACTOR SHALL COORDINATE WORK AND SCHEDULE WORK ACTIVITIES WITH OTHER DISCIPLINES. 12. ERECTION SHALL BE DONE IN A WORKMANLIKE MANNER BY COMPETENT EXPERIENCED WORKMAN IN ACCORDANCE WITH APPLICABLE CODES AND THE BEST ACCEPTED PRACTICE. ALL MEMBERS SHALL BE LAID PLUMB AND TRUE AS INDICATED ON THE DRAWINGS. 13. SEAL PENETRATIONS THROUGH FIRE RATED AREAS WITH UL LISTED MATERIALS APPROVED BY LOCAL JURISDICTION. SUBCONTRACTOR SHALL KEEP AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DEBRIS. 14. WORK PREVIOUSLY COMPLETED IS REPRESENTED BY LIGHT SHADED LINES AND NOTES. THE SCOPE OF WORK FOR THIS PROJECT IS REPRESENTED BY DARK SHADED LINES AND NOTES. SUBCONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR OF ANY EXISTING CONDITIONS THAT DEVIATE FROM THE DRAWINGS PRIOR TO THE BEGINNING CONSTRUCTION. 15. SUBCONTRACTOR SHALL PROVIDE WRITTEN NOTICE TO THE CONSTRUCTION MANAGER 48 HOURS PRIOR TO COMMENCEMENT OF WORK. 16. THE SUBCONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT SUBCONTRACTOR'S EXPENSE TO THE SATISFACTION OF THE OWNER. 17. THE SUBCONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. 18. GENERAL CONTRACTOR SHALL COORDINATE AND MAINTAIN ACCESS FOR ALL TRADES AND SUBCONTRACTORS TO THE SITE AND/OR BUILDING. 19. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SECURITY OF THE SITE FOR THE DURATION OF CONSTRUCTION UNTIL JOB COMPLETION. 20. THE GENERAL CONTRACTOR SHALL MAINTAIN IN GOOD CONDITION ONE COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA, AND CHANGE ORDERS ON THE PREMISES AT ALL TIMES. 21. THE GENERAL CONTRACTOR AND SUBCONTRACTOR SHALL PROVIDE PORTABLE FIRE EXTINGUISHERS WITH A RATING OF NOT LESS THAN 2-A OT 2-A:10-B:C AND SHALL BE WITHIN 25 FEET OF TRAVEL DISTANCE TO ALL PORTIONS OF WHERE THE WORK IS BEING COMPLETED DURING CONSTRUCTION. 22. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES SHALL BE PROTECTED AT ALL TIMES, AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY THE ARCHITECT/ENGINEER. EXTREME CAUTION SHOULD BE USED BY THE SUBCONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. SUBCONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS SHALL INCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION, B) CONFINED SPACE, C) ELECTRICAL SAFETY, D) TRENCHING & EXCAVATION. 23. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED, CAPPED, PLUGGED OR OTHERWISE DISCONNECTED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, AS DIRECTED BY THE RESPONSIBLE ARCHITECT/ENGINEER, AND SUBJECT TO THE APPROVAL OF THE OWNER AND/OR LOCAL UTILITIES. 24. THE AREAS OF THE OWNER'S PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION. 25. SUBCONTRACTOR SHALL MINIMIZE DISTURBANCE TO THE EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE FEDERAL AND LOCAL JURISDICTION FOR EROSION AND SEDIMENT CONTROL. 26. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUNDING. FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. 27. THE SUBGRADE SHALL BE BROUGHT TO A SMOOTH UNIFORM GRADE AND COMPACTED TO 95 PERCENT STANDARD PROCTOR DENSITY UNDER PAVEMENT AND STRUCTURES AND 80 PERCENT STANDARD PROCTOR DENSITY IN OPEN SPACE. ALL TRENCHES IN PUBLIC RIGHT OF WAY SHALL BE BACKFILLED WITH FLOWABLE FILL OR OTHER MATERIAL PRE-APPROVED BY THE LOCAL JURISDICTION. 28. ALL NECESSARY RUBBISH, STUMPS, DEBRIS, STICKS, STONES, AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF IN A LAWFUL MANNER. 29. ALL BROCHURES, OPERATING AND MAINTENANCE MANUALS, CATALOGS, SHOP DRAWINGS, AND OTHER DOCUMENTS SHALL BE TURNED OVER TO THE GENERAL CONTRACTOR AT COMPLETION OF CONSTRUCTION AND PRIOR TO PAYMENT. 30. SUBCONTRACTOR SHALL SUBMIT A COMPLETE SET OF AS-BUILT REDLINES TO THE GENERAL CONTRACTOR UPON COMPLETION OF PROJECT AND PRIOR TO FINAL PAYMENT. 31. SUBCONTRACTOR SHALL LEAVE PREMISES IN A CLEAN CONDITION. 32. THE NEW FACILITY WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SEWER SERVICE, AND IS NOT FOR HUMAN HABITAT (NO HANDICAP ACCESS REQUIRED). 33. OCCUPANCY IS LIMITED TO PERIODIC MAINTENANCE AND INSPECTION, APPROXIMATELY 2 TIMES PER MONTH, BY AT&T TECHNICIANS. 34. NO OUTDOOR STORAGE OR SOLID WASTE CONTAINERS ARE PROPOSED . 35. ALL MATERIAL SHALL BE FURNISHED AND WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST REVISION AT&T MOBILITY GROUNDING STANDARD "TECHNICAL SPECIFICATION FOR CONSTRUCTION OF GSM/GPRS WIRELESS SITES" AND "TECHNICAL SPECIFICATION FOR FACILITY GROUNDING". IN CASE OF A CONFLICT BETWEEN THE CONSTRUCTION SPECIFICATION AND THE DRAWINGS, THE DRAWINGS SHALL GOVERN. 36. SUBCONTRACTORS SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS REQUIRED FOR CONSTRUCTION. IF SUBCONTRACTOR CANNOT OBTAIN A PERMIT, THEY MUST NOTIFY THE GENERAL CONTRACTOR IMMEDIATELY. 37. SUBCONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY BASIS. 38. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM SITE VISITS AND/OR DRAWINGS PROVIDED BY THE SITE OWNER. CONTRACTORS SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. 39. NO WHITE STROBIC LIGHTS ARE PERMITTED. LIGHTING IF REQUIRED, WILL MEET FAA STANDARDS AND REQUIREMENTS. 40. ALL COAXIAL CABLE INSTALLATIONS TO FOLLOW MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. 41. NO NOISE, SMOKE, DUST, OR VIBRATIONS WILL RESULT FROM THIS FACILITY. (DELETE THIS NOTE IF THE SITE WILL HAVE A GENERATOR). 42. NO ADDITIONAL PARKING TO BE PROPOSED . EXISTING ACCESS AND PARKING TO REMAIN. (REVISE THIS NOTE ACCORDING TO THE SITE CONFIGURATION). 43. NO LANDSCAPING IS NEW AT THIS SITE, UNLESS NOTED OTHERWISE. (REVISE THIS NOTE ACCORDING TO THE SITE CONFIGURATION). 44. CONTRACTOR SHALL ASSESS & REPAIR ANY DAMAGED AND/ OR MISSING CABLE TRAY COVERS, SLEEPERS, AND/ OR COVER CLAMPS. 45. CONTRACTOR SHALL ASSESS AND REPLACE ANY MISSING OR DAMAGED COLOR CODED, CONTINUOUS, PHOTO-LUMINESCENT/REFLECTIVE MARKING ON ALL EXISTING CABLE TRAY. 46. CONTRACTOR SHALL ASSESS AND REPLACE ANY MISSING OR DAMAGED ANTENNA "TRANSMITTER" LABELS & ENSURE MARKING ARE AFFIXED TO ANY EXISTING & NEW ANTENNA. ANTENNA MOUNT OR CONSPICUOUS LOCATION NEAR THE ANTENNA. 47. THE PROPOSED MODIFICATIONS WILL NOT RESULT IN AN INCREASE IN THE HEIGHT OF THE EXISTING STRUCTURE. 48. THE PROPOSED MODIFICATIONS WILL NOT REQUIRE THE EXTENSION OF THE SITE BOUNDARY. 49. THE PROPOSED MODIFICATIONS WILL NOT INCREASE NOISE LEVELS AT THE FACILITY BY SIX DECIBELS OR MORE OR TWO LEVELS THAT EXCEED STATE AND LOCAL CRITERIA. 50. THE OPERATION OF THE REPLACEMENT ANTENNAS WILL NOT INCREASE RADIO FREQUENCY EMISSIONS AT THE FACILITY TO A LEVEL AT OR ABOVE THE FEDERAL COMMUNICATIONS COMMISSION SAFETY STANDARD. 51. THE PROPOSED MODIFICATION WILL NOT CAUSE A CHANGE OR ALTERATION IN THE PHYSICAL OR ENVIRONMENTAL CHARACTERISTICS OF THE SITE. GENERAL NOTES mobility corp. SHEET TITLE SHEET NUMBER DRAWN BY: CHECKED BY: - JS 1452 EDINGER AVE. TUSTIN, CA 92780 PROJECT NO: AT&T SITE NO:CLL03413 10086996 90% CD'S FOR REVIEW EXPIRATION DATE: 06/30/2027 APPLICANT: CLL03413 MAIN / DYER 2621 & 2621 3/4 SOUTH BIRCH STREET SANTA ANA, CA 92707 JS03/17/2025A ENGINEER: A-1 PLANS PREPARED BY: DATE SIGNED: 12/11/2025 95% CD'S - CLIENT RLs RDL05/01/2025B 100% CD'S FOR SUBMITTAL DS12/11/20250 SITE PLAN 1 A-1 NE N E SESW W NW S SITE PLANNOTE: THESE DRAWINGS HAVE BEEN CREATED UTILIZING AS-BUILTS PROVIDED BY AT&T AND WITHOUT A SURVEY OR SITE MEASUREMENTS. PLEASE VERIFY ALL DIMENSIONS, LENGTHS, PROPERTY LINES, CONDUIT RUNS, ETC. PRIOR TO CONSTRUCTION. 1,2 A-5 EXISTING BUILDING PROPERTY LINE S B I R C H S T 1,2 A-4 1,2 A-2 "A" SECTOR @ 100° "B" SE CTOR @ 210° "C" SE CTOR @ 330° LOCATION OF EXISTING AND NEW AT&T GROUND EQUIPMENT AREA PROPERTY LINE PROPERTY LINE EXISTING STORAGE YARD EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING STORAGE YARD EXISTING STORAGE YARD EXISTING STORAGE YARD EXISTING STORAGE YARD LOCATION OF EXISTING AND NEW AT&T ANTENNA AREA 1 A-3.1 1 A-3.2 EXISTING BUILDING EXISTING BUILDING EXISTING UTILITY POLE (TYP.) EXISTING PARKING AREA (TYP.) APN: 410-391-03 mobility corp. SHEET TITLE SHEET NUMBER DRAWN BY: CHECKED BY: - JS 1452 EDINGER AVE. TUSTIN, CA 92780 PROJECT NO: AT&T SITE NO:CLL03413 10086996 90% CD'S FOR REVIEW EXPIRATION DATE: 06/30/2027 APPLICANT: CLL03413 MAIN / DYER 2621 & 2621 3/4 SOUTH BIRCH STREET SANTA ANA, CA 92707 JS03/17/2025A ENGINEER: A-2 PLANS PREPARED BY: DATE SIGNED: 12/11/2025 95% CD'S - CLIENT RLs RDL05/01/2025B 100% CD'S FOR SUBMITTAL DS12/11/20250 EXISTING EQUIPMENT LAYOUT 2 A-2 1 NE N ESE SW W NW S EQUIPMENT LAYOUTS NEW EQUIPMENT LAYOUT NOTE: FINAL BBU CONFIGURATION: (2) XMU, (1) 6630, (1) DAFI NOTE: EXISTING BBU CONFIGURATION: (1) 5216, (2) XMU, (1) 6630, (1) DAFI NE N ESE SW W NW S (E) AT&T DTTV BOX (E) AT&T HVAC (E) AT&T HVAC (E) AT&T RRUS-E2 B2 TO REMAIN (TOTAL 3) (E) AT&T POWER PANEL (E) AT&T DC12-48-60-0-25E NEMA BOX (E) AT&T FIRE EXTINGUISHER (E) AT&T GPS ANTENNA (E) AT&T FIF RACK WITH EXISTING EQUIPMENT: (2) XMU (1) 6630 (1) DAFI (2) DC12-48-60-RM NEMA BOXES TO REMAIN (1) 5216 TO BE REMOVED (E) AT&T BATTERY RACK WITH EXISTING EQUIPMENT: (4) M12V180FTX BATTERIES (E) AT&T POWER PLANT WITH EXISTING EQUIPMENT: (1) NETSURE 7100 INDOOR POWER PLANT (2) C48/24-1500 CONVERTERS (20) R48-2000E3 RECTIFIERS (12) M12V180FTX BATTERIES (3) 50A BREAKERS (E) AT&T H-FRAME (TYP.) (E) AT&T UMTS CABINET (E) AT&T GPS ANTENNA 7'-0" EXISTING AT&T EQUIPMENT SHELTER 13 ' - 1 " EX I S T I N G A T & T E Q U I P M E N T S H E L T E R (E) AT&T GENERATOR PLUG BOX BELOW (E) AT&T TELCO BOX (E) ACCESS DOOR (E) AT&T DTTV BOX (E) AT&T HVAC (E) AT&T HVAC (E) AT&T RRUS-E2 B2 (TOTAL 3) (E) AT&T POWER PANEL (E) AT&T DC12-48-60-0-25E NEMA BOX (E) AT&T FIRE EXTINGUISHER (E) AT&T GPS ANTENNA (E) AT&T FIF RACK WITH EXISTING EQUIPMENT: (2) XMU (1) 6630 (1) DAFI (2) DC12-48-60-RM NEMA BOXES (E) AT&T BATTERY RACK WITH EXISTING EQUIPMENT: (4) M12V180FTX BATTERIES (E) AT&T POWER PLANT WITH EXISTING EQUIPMENT: (1) NETSURE 7100 INDOOR POWER PLANT (2) C48/24-1500 CONVERTERS (20) R48-2000E3 RECTIFIERS (12) M12V180FTX BATTERIES (3) 50A BREAKERS (E) AT&T H-FRAME (TYP.) (E) AT&T UMTS CABINET (E) AT&T GPS ANTENNA 7'-0" EXISTING AT&T EQUIPMENT SHELTER 13 ' - 1 " EX I S T I N G A T & T E Q U I P M E N T S H E L T E R (E) AT&T GENERATOR PLUG BOX BELOW (E) AT&T TELCO BOX (E) ACCESS DOOR mobility corp. SHEET TITLE SHEET NUMBER DRAWN BY: CHECKED BY: - JS 1452 EDINGER AVE. TUSTIN, CA 92780 PROJECT NO: AT&T SITE NO:CLL03413 10086996 90% CD'S FOR REVIEW EXPIRATION DATE: 06/30/2027 APPLICANT: CLL03413 MAIN / DYER 2621 & 2621 3/4 SOUTH BIRCH STREET SANTA ANA, CA 92707 JS03/17/2025A ENGINEER: A-3.1 PLANS PREPARED BY: DATE SIGNED: 12/11/2025 95% CD'S - CLIENT RLs RDL05/01/2025B 100% CD'S FOR SUBMITTAL DS12/11/20250 EXISTING ANTENNA PLAN 1 A-3.1 NE N E SESW W NW S EXISTING ANTENNA PLAN ANTENNA RF SCHEDULE EXISTING RF SCHEDULE SECTOR ANTENNA MODEL NUMBER AZIMUTH RAD CENTER RRU MODEL NUMBER SURGE PROTECTION MODEL NUMBER A1 TPA65R-BU6D 100° 52'-0"8843 B2/B66A / 4449 B5/B12 (2) DC6-48-60-18-8C-EV A2 AIR6449 B77D 100°53'-0"INTEGRATED A3 80010965 100° 52'-0" 4478 B14 A4 JAHH-65B-R3B-V3 100° 52'-0"RRUS-32 B30 / RRUS-E2 B29 (BOTTOM) B1 TPA65R-BU6D 210° 52'-0"8843 B2/B66A / 4449 B5/B12 (1) DC6-48-60-18-8C-EV B2 AIR6449 B77D 210°53'-0"INTEGRATED B3 80010965 210° 52'-0" 4478 B14 B4 JAHH-65B-R3B-V3 210° 52'-0"RRUS-32 B30 / RRUS-E2 B29 (BOTTOM) C1 TPA65R-BU6D 330° 52'-0" 8843 B2/B66A / 4449 B5/B12 (1) DC6-48-60-18-8C-EV C2 AIR6449 B77D 330°53'-0"INTEGRATED C3 80010965 330° 52'-0" 4478 B14 C4 JAHH-65B-R3B-V3 330° 52'-0"RRUS-32 B30 / RRUS-E2 B29 (BOTTOM) RFDS ID 35051 RFDS REV FINAL RFDS DATE 02/24/2025 A1 A2 A3 A4 B1 B2 B3 B4 C4 C3 C2 C1 (E) AT&T DC6-48-60-18-8C-EV SURGE PROTECTORS TO REMAIN (4 TOTAL) (E) AT&T ANTENNAS TO REMAIN (1 PER SECTORS B & C, 2 TOTAL) (E) AT&T ANTENNAS TO BE RELOCATED (1 PER SECTOR A, 1 TOTAL) (E) AT&T ANTENNAS TO BE REMOVED (1 PER SECTOR, 3 TOTAL) 3'-0" TYP. 1'-0" TYP. 3'-0" TYP. (E) AT&T ANTENNAS TO REMAIN (1 PER SECTORS B & C, 2 TOTAL) (E) AT&T ANTENNAS TO REMAIN (1 PER SECTORS "B" AND "C", 2 TOTAL) (E) HORIZONTAL MOUNTS TO BE RE-ALIGNED TO AZIMUTHS (TO REMOVE SKEW, TYP. 3) (E) AT&T ANTENNA TO BE RELOCATED (1 PER SECTOR A, 1 TOTAL) (E) AT&T ANTENNAS TO BE RELOCATED (1 PER SECTOR A, 1 TOTAL) (E) AT&T RRUS-32 B30 TO REMAIN (1 PER SECTORS B & C, 2 TOTAL) (E) AT&T RRUS-32 B30 TO BE RELOCATED (1 PER SECTOR, 3 TOTAL) (E) AT&T RRU 4478 B14 TO BE RELOCATED (1 PER SECTOR, 3 TOTAL) (E) AT&T RRU 8843 B2/B66A TO BE RELOCATED (1 PER SECTOR, 3 TOTAL) (E) AT&T RRU 4449 B5/B12 TO BE RELOCATED (1 PER SECTOR, 3 TOTAL) "A" SECTOR @ 100° "B" SE CTOR @ 210° "C" SE CTOR @ 330° (E) MONOPOLE mobility corp. SHEET TITLE SHEET NUMBER DRAWN BY: CHECKED BY: - JS 1452 EDINGER AVE. TUSTIN, CA 92780 PROJECT NO: AT&T SITE NO:CLL03413 10086996 90% CD'S FOR REVIEW EXPIRATION DATE: 06/30/2027 APPLICANT: CLL03413 MAIN / DYER 2621 & 2621 3/4 SOUTH BIRCH STREET SANTA ANA, CA 92707 JS03/17/2025A ENGINEER: A-3.2 PLANS PREPARED BY: DATE SIGNED: 12/11/2025 95% CD'S - CLIENT RLs RDL05/01/2025B 100% CD'S FOR SUBMITTAL DS12/11/20250 NEW ANTENNA PLAN 1 A-3.2 NE N E SESW W NW S NEW ANTENNA PLAN ANTENNA RF SCHEDULE FINAL RF SCHEDULE SECTOR ANTENNA MODEL NUMBER AZIMUTH RAD CENTER RRU MODEL NUMBER SURGE PROTECTION MODEL NUMBER A1 JAHH-65B-R3B-V3 100° 52'-0"RRUS 32 B30, RRUS E2 B29 (2) DC6-48-60-18-8C-EV A2 80010965 100° 52'-0" RRU 4478 B14 A3 AIR6472 B77G B77M 100°53'-6"INTEGRATED A4 TPA65R-BU6D 100° 52'-0"RRU 8843 B2/B66A, RRU 4449 B5/B12 B1 TPA65R-BU6D 210° 52'-0"8843 B2/B66A / 4449 B5/B12 (1) DC6-48-60-18-8C-EV B2 AIR6472 B77G B77M 210°53'-6"INTEGRATED B3 80010965 210° 52'-0" 4478 B14 B4 JAHH-65B-R3B-V3 210° 52'-0"RRUS-32 B30 / RRUS-E2 B29 (BOTTOM) C1 TPA65R-BU6D 330° 52'-0" 8843 B2/B66A / 4449 B5/B12 (1) DC6-48-60-18-8C-EV C2 AIR6472 B77G B77M 330°53'-6" INTEGRATED C3 80010965 330° 52'-0" 4478 B14 C4 JAHH-65B-R3B-V3 330° 52'-0"RRUS-32 B30 / RRUS-E2 B29 (BOTTOM) RFDS ID 35051 RFDS REV FINAL RFDS DATE 02/24/2025 A1 A2 A3 A4 C4 C3 C2 C1 B1 B2 B3 B4 2'-0" 2'-0" 3'-0" 3'-0" 2'-0" 2'-0" 2'-0" 2'-0" 3'-0" "A" SECTOR @ 100° "B" SE CTOR @ 210° "C" SE CTOR @ 330° NOTE: REMOVE ALL MDT BRACKETS (E) AT&T DC6-48-60-18-8C-EV SURGE PROTECTORS (4 TOTAL) (E) AT&T ANTENNAS (1 PER SECTORS B & C, 2 TOTAL) (E) AT&T ANTENNA RELOCATED (1 PER SECTOR A, 1 TOTAL) (E) AT&T ANTENNAS (1 PER SECTORS B & C, 2 TOTAL) (E) AT&T ANTENNAS (1 PER SECTORS "B" AND "C", 2 TOTAL) (E) HORIZONTAL MOUNTS RE-ALIGNED TO AZIMUTHS TO REMOVE SKEW, TYP. 3 (E) AT&T ANTENNA RELOCATED (1 PER SECTOR A, 1 TOTAL) (E) AT&T ANTENNA RELOCATED (1 PER SECTOR A, 1 TOTAL) (E) AT&T RRUS-32 B30 (1 PER SECTOR, 3 TOTAL) (E) AT&T RRU 4478 B14 RELOCATED (1 PER SECTOR, 3 TOTAL) (E) AT&T RRU 8843 B2/B66A RELOCATED (1 PER SECTOR, 3 TOTAL) (E) AT&T RRU 4449 B5/B12 RELOCATED (1 PER SECTOR, 3 TOTAL) NEW AT&T ANTENNAS (1 PER SECTOR, 3 TOTAL) 1 D-1 (E) MONOPOLE TARP RECOMMENDATIONS: 1) IF THE LOAD DIFFERS FROM THAT DESCRIBED IN TABLE 2 (PER DETAIL 4/D-1) OF THIS REPORT OR THE PROVISIONS OF THIS ANALYSIS ARE FOUND TO BE INVALID, ANOTHER STRUCTURAL ANALYSIS SHOULD BE PERFORMED. 2) THE MOUNT AND ITS CONNECTION HAVE SUFFICIENT CAPACITY TO CARRY THE EXISTING AND PROPOSED LOADING CONFIGURATION. IN ORDER FOR THE RESULTS OF THIS ANALYSIS TO BE VALID, THE MOUNT MODIFICATIONS LISTED BELOW MUST BE COMPLETED: a) REUSE EXISTING MOUNT PIPE(S) IN EMPTY ANTENNA POSITIONS, WHERE AN EXISTING ANTENNA ISLOCATED OR WHERE AN EXISTING ANTENNA IS BEING RELOCATED TO. RECONFIGURE ANTENNA MOUNT PIPE POSITIONS TO 4 POSITIONS PER SECTOR PER REFERENCED CONSTRUCTION DRAWINGS. b) REPLACE EXISTING ANTENNA MOUNT PIPES AT POSITION A3, B2 AND C2 WITH (3) SITE PRO P30120, 2.5 SCH.40 X 10’-0” MOUNT PIPES (CONMAT ITEM NO. ANT.16008) CONNECTED TO THE FACE HORIZONTAL WITH (3) SITE PRO SP219-H PIPE CROSS SUPPORT PLATES (CONMAT ITEM NO. ANT.55968) FOR PROPOSED ANTENNAS. c) INSTALL (6) SITE PRO P2120, 2.0 SCH.40 X 10’-0” MOUNT PIPES (CONMAT ITEM NO. ANT.55993 TO BE CONNECTION TO MOUNT SUPPORT ARMS WITH (3) SITE PRO BBPM-U UNIVERSAL BACK TO BACK PIPE MOUNT ASSEMBLIES (CONMAT ITEM NO. ANT.58819) FOR RRU AND SURGE MOUNTING. 3) RADIOS TO BE MOUNTED ON MOUNT ARMS INSTEAD OF FRONT HORIZONTAL TO BE REQUIRED DISTANCE FROM FACE OF MOUNT AND PIPES TO BE REMOVED FROM FRONT FACE. 4 ANTENNA PIPES TO BE DISTRIBUTED EQUALLY ACROSS MOUNT FACE NEW AT&T 2.5 SCH.40 X 10' LONG MOUNT PIPE (1 PER POSITION "A3", "B2", AND "C2", 3 TOTAL) NEW AT&T 2.0 SCH.40 X 10' LONG MOUNT PIPE (2 PER SECTOR, 6 TOTAL) 1'-0" TYP . mobility corp. SHEET TITLE SHEET NUMBER DRAWN BY: CHECKED BY: - JS 1452 EDINGER AVE. TUSTIN, CA 92780 PROJECT NO: AT&T SITE NO:CLL03413 10086996 90% CD'S FOR REVIEW EXPIRATION DATE: 06/30/2027 APPLICANT: CLL03413 MAIN / DYER 2621 & 2621 3/4 SOUTH BIRCH STREET SANTA ANA, CA 92707 JS03/17/2025A ENGINEER: A-4 PLANS PREPARED BY: DATE SIGNED: 12/11/2025 95% CD'S - CLIENT RLs RDL05/01/2025B 100% CD'S FOR SUBMITTAL DS12/11/20250 2 A-4 1 ELEVATIONS NEW EAST ELEVATION EXISTING EAST ELEVATION GROUND LEVEL 0'-0" A.G.L. (E) MONOPOLE TOP OF EXISTING MONOPOLE 60'-0" A.G.L. (E) AT&T EQUIPMENT ROOM GROUND LEVEL 0'-0" A.G.L. EXISTING AT&T ANTENNA RAD CENTER 52'-0" A.G.L. (E) MONOPOLE EXISTING AT&T ANTENNA RAD CENTER 52'-0" A.G.L. NEW AT&T ANTENNA RAD CENTER ±53'-6" A.G.L. 1 A-3.1 EXISTING AND NEW AT&T ANTENNAS AND EQUIPMENT. SEE NEW ANTENNA PLANS. 1 A-3.2 EXISTING AT&T ANTENNA RAD CENTER 53'-0" A.G.L. EXISTING AT&T ANTENNAS AND EQUIPMENT. SEE EXISTING ANTENNA PLAN. TOP OF EXISTING MONOPOLE 60'-0" A.G.L. TOP OF EXISTING FENCE 6'-0" A.G.L. TOP OF EXISTING FENCE 6'-0" A.G.L. (E) AT&T EQUIPMENT ROOM (E) OTHER CARRIER EQUIPMENT ROOM (E) OTHER CARRIER EQUIPMENT ROOM TOP OF EXISTING ANTENNAS 55'-0" A.G.L.EXISTING AT&T ANTENNA RAD CENTER 53'-9" A.G.L. TOP OF EXISTING & NEW ANTENNAS 55'-0" A.G.L. mobility corp. SHEET TITLE SHEET NUMBER DRAWN BY: CHECKED BY: - JS 1452 EDINGER AVE. TUSTIN, CA 92780 PROJECT NO: AT&T SITE NO:CLL03413 10086996 90% CD'S FOR REVIEW EXPIRATION DATE: 06/30/2027 APPLICANT: CLL03413 MAIN / DYER 2621 & 2621 3/4 SOUTH BIRCH STREET SANTA ANA, CA 92707 JS03/17/2025A ENGINEER: A-5 PLANS PREPARED BY: DATE SIGNED: 12/11/2025 95% CD'S - CLIENT RLs RDL05/01/2025B 100% CD'S FOR SUBMITTAL DS12/11/20250 2 A-5 1 ELEVATIONS NEW SOUTH ELEVATION EXISTING SOUTH ELEVATION GROUND LEVEL 0'-0" A.G.L. (E) MONOPOLE (E) AT&T EQUIPMENT ROOM EXISTING AT&T ANTENNA RAD CENTER 52'-0" A.G.L. 1 A-3.1 EXISTING AT&T ANTENNA RAD CENTER 53'-0" A.G.L. EXISTING AT&T ANTENNAS AND EQUIPMENT. SEE EXISTING ANTENNA PLAN. TOP OF EXISTING FENCE 6'-0" A.G.L. (E) OTHER CARRIER EQUIPMENT ROOM GROUND LEVEL 0'-0" A.G.L. EXISTING AT&T ANTENNA RAD CENTER 52'-0" A.G.L. (E) MONOPOLE NEW AT&T ANTENNA RAD CENTER ±53'-6" A.G.L. EXISTING AND NEW AT&T ANTENNAS AND EQUIPMENT SEE NEW ANTENNA PLANS 1 A-3.2 TOP OF EXISTING MONOPOLE 60'-0" A.G.L. TOP OF EXISTING FENCE 6'-0" A.G.L. (E) AT&T EQUIPMENT ROOM (E) OTHER CARRIER EQUIPMENT ROOM TOP OF EXISTING MONOPOLE 60'-0" A.G.L. TOP OF EXISTING ANTENNAS 55'-0" A.G.L.EXISTING AT&T ANTENNA RAD CENTER 53'-9" A.G.L. TOP OF EXISTING & NEW ANTENNAS 55'-0" A.G.L. mobility corp. SHEET TITLE SHEET NUMBER DRAWN BY: CHECKED BY: - JS 1452 EDINGER AVE. TUSTIN, CA 92780 PROJECT NO: AT&T SITE NO:CLL03413 10086996 90% CD'S FOR REVIEW EXPIRATION DATE: 06/30/2027 APPLICANT: CLL03413 MAIN / DYER 2621 & 2621 3/4 SOUTH BIRCH STREET SANTA ANA, CA 92707 JS03/17/2025A ENGINEER: D-1 PLANS PREPARED BY: DATE SIGNED: 12/11/2025 95% CD'S - CLIENT RLs RDL05/01/2025B 100% CD'S FOR SUBMITTAL DS12/11/20250 D-1 867 7. 4 " 16 " ± 15.8" TOP 15.8" MANUFACTURER: ERICSSON MODEL: AIR6472 B77G B77M BAND WEIGHT: 77.16 LBS W/ MTG BRACKETS FREQUENCY: REFER TO RF DATA SHEET 7.4" 36 . 3 " FRONT SIDE ANTENNA PIPE MOUNT MOUNTING BRACKET BY MANUFACTURER PART # SXK 109 2064/1 MOUNTING BRACKET AIR ANTENNA DETAIL 1 ANTENNA MOUNTING ELEVATION 2 3 4 5 NEW AIR ANTENNA PER DETAIL 1/D-1 EXISTING ANTENNA PIPE MOUNT NOT USED NOT USED NOT USED NOT USEDTABLE 2- ANTENNA LOADING CONFIG. PER MOUNT ANALYSIS 20.7" 7. 7 " 20.7" 71 . 2 " 7.7" 71 . 2 " MANUFACTURER: ERICSSON MODEL: TPA65R-BU6D WEIGHT: 68.3 LBS W/ MTG BRACKETS FREQUENCY: REFER TO RF DATA SHEET TOP FRONT SIDE ANTENNA DETAIL mobility corp. SHEET TITLE SHEET NUMBER DRAWN BY: CHECKED BY: - JS 1452 EDINGER AVE. TUSTIN, CA 92780 PROJECT NO: AT&T SITE NO:CLL03413 10086996 90% CD'S FOR REVIEW EXPIRATION DATE: 06/30/2027 APPLICANT: CLL03413 MAIN / DYER 2621 & 2621 3/4 SOUTH BIRCH STREET SANTA ANA, CA 92707 JS03/17/2025A ENGINEER: G-1 PLANS PREPARED BY: DATE SIGNED: 12/11/2025 95% CD'S - CLIENT RLs RDL05/01/2025B 100% CD'S FOR SUBMITTAL DS12/11/20250 ANTENNA GROUNDING PLAN (TYP. PER SECTOR)1 G-1 NE N E SESW W NW S GROUNDING PLAN COMPRESSION TYPE CONNECTION GROUNDING WIRE CADWELD TYPE CONNECTION GROUND BUS BAR GROUNDING SYMBOLS: (E) ANTENNA GROUND WIRES TO BE RECONNECTED TO (N) ANTENNAS, TYP. (E) ANTENNA GROUND BAR TYP. (TO BE VERIFIED IN FIELD) mobility corp. SHEET TITLE SHEET NUMBER DRAWN BY: CHECKED BY: - JS 1452 EDINGER AVE. TUSTIN, CA 92780 PROJECT NO: AT&T SITE NO:CLL03413 10086996 90% CD'S FOR REVIEW EXPIRATION DATE: 06/30/2027 APPLICANT: CLL03413 MAIN / DYER 2621 & 2621 3/4 SOUTH BIRCH STREET SANTA ANA, CA 92707 JS03/17/2025A ENGINEER: G-2 PLANS PREPARED BY: DATE SIGNED: 12/11/2025 95% CD'S - CLIENT RLs RDL05/01/2025B 100% CD'S FOR SUBMITTAL DS12/11/20250 G-2 9 ANTENNA PIPE MOUNT GROUNDING DETAIL 1 CABLE GROUND KIT DETAIL TYPICAL GROUND LUG CONNECTION DETAIL 2 3 4 5 6GROUNDING WIRE CONNECTION ANTENNA GROUNDING BAR CONN. DETAIL ANTENNA (12") GROUND BAR DETAIL TYPICAL CADWELD TYPES COAX GROUND KIT 7 8RRU GROUNDING DETAIL 2621 & 2621 3/4 Birch St Modification to an existing unmanned wireless telecommunication facility. No proposed generator or additional batteries. Santa Ana Mark Phillips 619.379.3473 1/20/26 CITY OF SANTA ANA Planning and Building Agency FIRE EC ORANGE COUNTY FIRE AUTHORI �GOGy., Plan Referral Form °[IF asp Required for OCFA to review plans upon the request of the Building Department �6rHoa+� the answers on the Plan Submittal Criteria Form (on the reverse) are all "No" City / County Official Requesting Review: City / County Reference #: City / County: Contact Name: Title: Date: E-Mail: _ Phone #: Approved FOR PERMIT ISSUANCE Master ID: Date: ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County: OCFA COMMENTS: OCFA Authorization ElNo further action required on this specific plan type, based on information provided on: ❑ Project to be taken in for OCFA Review. Other: Name: Contact #: Date: Updated: 06/02/2020 rs TEP is a family of companies licensed to provide different services in different jurisdictions. Depending on the jurisdiction, professional engineering and land surveying services are provided by TEP OpCo LLC, a Delaware limited liability company, TEP Engineering, PLLC, a North Carolina professional limited liability company, or M&H Engineering, PLLC, a New York professional limited liability company. General contractor services are provided by TEPDB OpCo LLC, a Delaware limited liability company. We acquire the requisite licenses in each state. Additional information can be obtained from the company. October 21, 2025 Jon Maxwell M Squared Wireless 1387 Calle Avanzado San Clemente, CA 92673 326 Tryon Road • Raleigh • NC 27603 (949) 391-6824 (919) 661-6351 • Structures@tepgroup.net Subject: Appurtenance Mount Analysis Carrier Designation: AT&T Mobility Reconfiguration Site Number: CLL03413 Site Name: Main / Dyer FA Location Code:10086996 IWM Job Number:WSLOS0068683 Engineering Firm Designation: TEP Project Number: 272252.1169408 Site Data: 2621 South Birch Street, Santa Ana, Orange County, CA 92707 Latitude 33° 42' 42.20'', Longitude -117° 52' 11.30'' 60.0± Foot - Monopole Tower 52.0 Foot Mount Height - T-Arm Mount Dear Jon Maxwell, TEP is pleased to submit this “Appurtenance Mount Analysis” to determine the structural integrity of the antenna mount on the above-mentioned tower. The purpose of the analysis is to determine acceptability of the mount's stress level. Based on our analysis we have determined the stress level for the mount structure, under the following load case, to be: LC1: Existing + Proposed + Reserved Loading Sufficient Capacity* Note: See Table 2 for the existing, proposed, and reserved loading *Sufficient upon completion of the changes listed in the “Recommendations” section of this report The analysis has been performed in accordance with the ANSI/TIA-222-H Structural Standard for Antenna Supporting Structures, Antennas, and Small Wind Turbine Support Structures and the 2022 California Building Code, and the AT&T Mount Technical Guidance – Revision 25. All equipment proposed in this report shall be installed in accordance with the appurtenances listed in Table 2 for the determined available structural capacity to be effective. We at TEP appreciate the opportunity of providing our continuing professional services to you and M Squared Wireless. If you have any questions or need further assistance on this or any other projects, please give us a call. Respectfully submitted by: Adam M. Amortnont, P.E., S.E. Mount Capacity 62.1% October 21, 2025 T-Arm Mount Analysis Main / Dyer (CLL03413) TEP Project Number 272252.1169408 Page 2 ANALYSIS CRITERIA Table 1 - Mount Analysis Parameters Ultimate Wind Speed (MPH) Ice Thickness (in) Ice Wind Speed (MPH) Exposure Category Risk Category Topo Procedure Kzt Ss Maintenance Loads1,2 95 0.0 30 C II Method 2 1.0 1.279 Lm = 250 lbs Lv = 250 lbs Notes: 1) Maintenance loads applied per ANSI/TIA-222-H Chapter 16. Worst case positions are included in the RISA-3D Output. 2) Maintenance loads governs the structural capacity of the mount. Table 2 - Existing, Proposed, and Reserved Antenna Loading Configuration Existing/ Proposed/ Reserved Mount Level (ft) Ant CL (ft) Qty Antenna Model Mount Type Owner/ Tenant Final Loading Config. 52.0 53.5 3 Ericsson AIR6472 B77G B77M (3) T-Arm Mounts AT&T 52.0 3 Commscope JAHH-65B-R3B-V3 3 Kathrein 80010965 3 CCI TPA65R-BU6D 3 Ericsson 8843 B2/B66A 3 Ericsson 4449 B5/B12 3 Ericsson 4478 B14 3 Ericsson RRUS-E2 B29 3 Ericsson RRUS 32 B30 4 Raycap DC6-48-60-18-8C-EV ANALYSIS RESULTS Table 3 - Mount Component Stresses vs. Capacity Notes Component % Capacity Pass / Fail 1 Face Horizontals 62.1 Pass 1 Support Horizontals 26.4 Pass 1 Mount Pipes 27.3 Pass 1 Kickers 9.9 Pass 2 Connection Bolts 15.4 Pass 2 Connection Plates 43.1 Pass Structure Rating (max from all components) = 62.1% Notes: 1) See additional documentation in “Appendix A - RISA-3D Output” for calculations supporting the % capacity listed. 2) See additional documentation in “Appendix B - Additional Calculations” for calculations supporting the % capacity listed. October 21, 2025 T-Arm Mount Analysis Main / Dyer (CLL03413) TEP Project Number 272252.1169408 Page 3 Table 4 - Documents Provided Document Remarks Source Previous Mount Analysis DCI Pacific dated 9/30/2021 Site Number: CLL03413 M Squared Scoping Form AT&T Mobility, dated January 21, 2025 RFDS ID: 35051 M Squared Preliminary Construction Drawings M Squared Project No. 10086996 M Squared Correspondence Correspondence from M Squared Wireless in reference to the existing, proposed, and reserved loading. M Squared RECOMMENDATIONS 1) If the load differs from that described in Table 2 of this report or the provisions of this analysis are found to be invalid, another structural analysis should be performed. 2) The mount and its connection have sufficient capacity to carry the existing and proposed loading configuration. In order for the results of this analysis to be valid, the mount modifications listed below must be completed: a) Reuse existing mount pipe(s) in empty antenna positions, where an existing antenna is located or where an existing antenna is being relocated to. Reconfigure antenna mount pipe positions to 4 positions per sector per referenced construction drawings. b) Replace existing antenna mount pipes at position A3, B2 and C2 with (3) Site Pro P30120, 2.5 Sch.40 x 10’-0” Mount Pipes (CONMAT Item No. ANT.16008) connected to the face horizontal with (3) Site Pro SP219-H Pipe Cross Support Plates (CONMAT Item No. ANT.55968) for proposed antennas. c) Install (6) Site Pro P2120, 2.0 Sch.40 x 10’-0” Mount Pipes (CONMAT Item No. ANT.55993) to be connection to mount support arms with (3) Site Pro BBPM-U Universal back to back pipe mount assemblies (CONMAT Item No. ANT.58819) for RRU and surge mounting. ANALYSIS ASSUMPTIONS 1) The mount was built in accordance with the manufacturer’s specifications. 2) The mount has been maintained in accordance with the manufacturer’s specification. 3) The configuration of antennas, transmission cables, mounts and other appurtenances are as specified in Table 2. All mount components have been assumed to be in sufficient condition to carry their full design capacity for this analysis. Refer to the issued mapping for any structural and/or maintenance issues found during our site visit. 4) Serviceability with respect to antenna twist, tilt, roll, or lateral translation, is not checked and is left to the carrier or tower owner to ensure conformance. 5) TEP did not analyze the collar mount connection to the pole and assumes it to have sufficient structural capacity to transfer the applied forces from the mount to the tower. 6) All material grades used for this analysis, unless verified by mount manufacturer design, were assumed per AISC Table 2-4, 15th Edition. See RISA 3-D output for confirmation on grades used in this analysis. This analysis may be affected if any assumptions are not valid or have been made in error. TEP should be notified to determine the effect on the structural integrity of the mount. October 21, 2025 T-Arm Mount Analysis Main / Dyer (CLL03413) TEP Project Number 272252.1169408 Page 4 APPENDIX A RISA-3D OUTPUT Company :TEP Designer :AJ Job Number :TEP No. 272252.1169408 Model Name:CLL03413 (10086996) Y ZAX Envelope Only Solution TEP AJ TEP No. 272252.1169408 CLL03413(10086996) CITY OF SANTA ANA Planning and Building Agency 10/21 /2025 18:56 PM ApproV edS FOR PERMIT ISSUANCE Date: SK-1 Oct 21, 2025 at 02:17 PM MountAd RISA-3D Version 22 [ Mount.r3d ] Page 1 Company :TEP Designer :AJ Job Number :TEP No. 272252.1169408 Model Name:CLL03413 (10086996) y ZAX Loads: BLC 2, 0 Wind - No Ice Envelope Only Solution TEP AJ TEP No. 272252.1169408 0051 D45 I -0.0( 045 k CLL03413(10086996) CITY OF SANTA ANA Planning and Building Agency 10/21 /2025 18:56 PM ApproV edS FOR PERMIT ISSUANCE Date: SK-2 Oct 21, 2025 at 02:17 PM MountAd -0 -0 RISA-3D Version 22 [ Mount.r3d ] Page 2 Company :TEP Designer :AJ Job Number :TEP No. 272252.1169408 Model Name:CLL03413 (10086996) y ZAX 61 Member Code Checks Displayed (Enveloped) Envelope Only Solution TEP AJ TEP No. 272252.1169408 CLL03413(10086996) CITY OF SANTA ANA Planning and Building Agency 10/21 /2025 18:56 PM ApproV edS FOR PERMIT ISSUANCE le Check (Env) 9. > 1.0 90-1.0 _ .75-.90 50-.75 = 0.-.50 SK-3 Oct 21, 2025 at 02:17 PM MountAd RISA-3D Version 22 [ Mount.r3d ] Page 3 Company :TEP Designer :AJ Job Number :TEP No. 272252.1169408 Model Name:CLL03413 (10086996) y ZAX Member Shear Checks Displayed (Enveloped) Envelope Only Solution TEP AJ TEP No. 272252.1169408 CLL03413(10086996) CITY OF SANTA ANA Planning and Building Agency 10/21 /2025 18:56 PM ApproV edS FOR PERMIT ISSUANCE ar Check (Env) 1. > 1.0 90-1.0 _ .75-.90 50-.75 0.-.50 SK-4 Oct 21, 2025 at 02:17 PM MountAd RISA-3D Version 22 [ Mount.r3d ] Page 4 Company :TEP Designer :AJ Job Number :TEP No. 272252.1169408 Model Name:CLL03413 (10086996) y ZAX Envelope Only Solution TEP AJ TEP No. 272252.1169408 CLL03413(10086996) CITY OF SANTA ANA Planning and Building Agency 10/21 /2025 18:56 PM ApproV edS FOR PERMIT ISSUANCE Date: SK-5 Oct 21, 2025 at 02:18 PM MountAd RISA-3D Version 22 [ Mount.r3d ] Page 5 Company :TEP Designer :AJ Job Number :TEP No. 272252.1169408 Model Name:CLL03413 (10086996) y ZAX Envelope Only Solution TEP AJ TEP No. 272252.1169408 CLL03413(10086996) CITY OF SANTA ANA Planning and Building Agency 10/21 /2025 18:56 PM ApproV edS FOR PERMIT ISSUANCE Date: SK-6 Oct 21, 2025 at 02:18 PM MountAd RISA-3D Version 22 [ Mount.r3d ] Page 6 Company :TEP Designer :AJ Job Number :TEP No. 272252.1169408 Model Name:CLL03413 (10086996) Y ZAX N60 Envelope Only Solution TEP AJ TEP No. 272252.1169408 N52 CLL03413(10086996) CITY OF SANTA ANA Planning and Building Agency 10/21 /2025 18:56 PM ApproV edS FOR PERMIT ISSUANCE Date: SK-7 Oct 21, 2025 at 02:18 PM MountAd RISA-3D Version 22 [ Mount.r3d ] Page 7 Company :TEP Designer :AJ Job Number :TEP No. 272252.1169408 Model Name:CLL03413 (10086996) CITY OF SANTA ANA Planning and Building Agency 10/21 /2025 18:42 PM ApprovedS Number of Reported Sections 5 Master ID: _ Number of Internal Sections 100 Member Area Load Mesh Size in2 144 Consider Shear Deformation Yes Consider Torsional Warping Yes Approximate Mesh Size in 24 Transfer Forces Between Intersecting Wood Walls Yes Increase Wood Wall Nailing Capacity for Wind Loads Yes Include P-Delta for Walls Yes Optimize MasonrV and Wood Walls Yes Maximum Number of Iterations 3 Single No Multiple (Optimum) Yes Maximum No Global Axis corresponding to vertical direction Y Convert Existing Data Yes Default Global Plane for z-axis Xz Plate Local Axis Orientation Nodal Hot Rolled Steel AISC 15th 360-16 : LRFD Stiffness Ad'ustment No Notional Annex None Connections None Cold Formed Steel None Stiffness Ad'ustment Yes Iterative Wood None Temperature < 10OF Concrete None Masonry None Aluminum None Structure Type Building Stiffness Ad'ustment Yes Iterative Stainless None Stiffness Admustment Yes Iterative Compression Stress Block Rectangular Stress Block Analyze using Cracked Sections Yes Leave room for horizontal rebar splices 2*d bars acin Yes List forces which were ignored for design in the Detail Report Yes Column Min Steel 1 Column Max Steel 8 Rebar Material Spec ASTM A615 Warn if beam -column framing arrangement is not understood No Number of Shear Regions 4 Region 2 & 3 Spacing Increase Increment in 4 Code ASCE 7-16 Risk Category I or II Drift Cat Other CE RISA-3D Version 22 [ MountAd ] Page 1 CITY OF SANTA ANA Planning and Building Agency Company :TEP Designer :AJ Job Number :TEP No. 272252.1169408 Model Name:CLL03413 (10086996) 10/21 /2025 18:42 PM ApproV edS Base Elevation ft Master ID: Include the weight of the structure in base shear calcs Yes Uate S, 1 SD 1 SD 1 T sec 5 T Z sec T X sec C,Z 0.02 C,X 0.02 C,Ex . Z 0.75 C Ex . X 0.75 RZ 3 RX 3 Q0Z 1 Dox 1 C,Z 1 CdX 1 Z 1 ip X 1 CE RISA-3D Version 22 [ Mount.r3d ] Page 2 Company :TEP Designer :AJ Job Number :TEP No. 272252.1169408 Model Name:CLL03413 (10086996) CITY OF SANTA ANA Planning and Building Agency 10/21 /2025 18:42 PM ApproV edS Material Size Pieces I enathrftll r. _ WeiahtfKl 1 General Members 2 RIGID 14 3.7 3 Total General 14 3.7 0 4 5 Hot Rolled Steel 6 A500 Gr. B Rect HSS4X4X3 2 6 0.053 7 A53 Gr.B PIPE 2.0 12 106.8 0.371 8 A53 Gr.B PIPE 2.5 2 20 0.11 9 A53 Gr.B PIPE 3.0 2 25 0.176 10 A53 Gr.B PIPE 4.0 2 2.5 0.025 11 Total HR Steel 20 160.3 0.734 Hot Rolled Steel Properties I ahel F fksil G fksil Nil Therm CnPff 11P5°F-11 Density fk/ft31 Yield fksil Rv Fu fksil Rt 1 A53 Gr.B 29000 11154 0.3 0.65 0.49 35 1.6 60 1.2 2 A500 Gr. B Rect 29000 11154 0.3 0.65 0.49 46 1.4 58 1.3 3 A36 Gr.36 29000 11154 0.3 0.65 0.49 36 1.5 58 1.2 Hot Rolled Steel Section Sets I ahel Shane Tvne Design List Material Desian Rule Area [in zllvv fin41177 fin41 .I fin41 1 Face Horizontal PIPE 3.0 None None A53 Gr.B Typical 2.07 2.85 2.85 5.69 2 Support Horizontal HSS4X4X3 None None A500 Gr. B Rect Typical 2.58 6.21 6.21 10 3 Support Vertical PIPE 4.0 None None A53 Gr.B Typical 2.96 6.82 6.82 13.6 4 Mount Pie PIPE 2.0 None None A53 Gr.B TVpical 1.02 0.627 0.627 1.25 5 Mount Pie 2.5 PIPE 2.5 None None A53 Gr.B Typical 1.61 1.45 1.45 2.89 6 RRU Pie PIPE 2.0 None None A53 Gr.B Typical 1.02 0.627 0.627 1.25 71 Kicker PIPE 2.0 None None A53 Gr.B Typical 1.02 0.627 0.627 1.25 Node Boundary Conditions Nnde I ahel X fk/inl Y fk/inl 7 fk/inl X Rnt rk-ft/radl Y Rnt fk-ft/radl 7 Rot rk-ft/radl 1 SF1-1 Reaction Reaction Reaction Reaction Reaction Reaction 2 N32 Reaction Reaction Reaction Reaction Reaction Reaction 3 N40 Reaction Reaction Reaction Reaction Reaction Reaction 4 N66 Reaction Reaction Reaction Reaction Reaction Reaction Node Coordinates Label X fftl Y fftl z rftl Detach From Dianhraom 1 FF1 3.332667 0 -6.25 2 FF2 3.332667 0 6.25 3 SF1-1 0.045577 0 0.520945 4 SF1-3 3 0 0 5 SF1-V3A 3 0.625 0 6 SF1-V3B 3 -0.625 0 7 N19 3.332667 0 0 8 N22 3.582667 0 -1.91667 9 N23 3.582667 5 -1.91667 10 N24 3.582667 -5 -1.91667 11 N25 3.332667 0 -1.91667 12 N26 3.582667 0 1.91666 Nol RISA-3D Version 22 [ Mount.r3d ] Page 3 Company :TEP Designer :AJ Job Number :TEP No. 272252.1169408 Model Name:CLL03413 (10086996) Label X [ft] y [ft] Z [ft] CITY OF SANTA ANA Planning and Building Agency 10/21 /2025 18:42 PM ApproV edS Detach IFfpjp Diaphragm 131 N27 3.582667 4.5 1.91666 14 N28 3.582667 -4.5 1.91666 15 N29 3.332667 0 1.91666 16 N50A 3.582667 0 5.75 17 N51 3.582667 4.5 5.75 18 N52 3.582667 -4.5 5.75 19 N53 3.332667 0 5.75 20 N44A 3.582667 0 -5.75 21 N45A 3.582667 4.5 -5.75 22 N46A 3.582667 -4.5 -5.75 23 N47A 3.332667 0 -5.75 24 N32 0.045577 -5.75 0.520945 25 N41 2.852279 0 0.026047 26 N30 1.227346 0 0.312567 27 N31 1.270758 0 0.558769 28 N33 1.183934 0 0.066365 29 N34 1.270758 5 0.558769 30 N35 1.183934 5 0.066365 31 N36 1.270758 -5 0.558769 32 N37 1.183934 -5 0.066365 33 N38 3.332667 0 8.75 34 N39 3.332667 0 21.25 35 N40 0 0 15 36 N42 3 0 15 37 N43 3 0.625 15 38 N44 3 -0.625 15 39 N45 3.332667 0 15 40 N46 1.2 0 15.25 41 N47 3.582667 0 13.08333 42 N48 3.582667 4.5 13.08333 43 N49 3.582667 -4.5 13.08333 44 N50 3.332667 0 13.08333 45 N54 3.582667 0 16.91666 46 N55 3.582667 5 16.91666 47 N56 3.582667 -5 16.91666 48 N57 3.332667 0 16.91666 49 N58 3.582667 0 20.75 50 N59 3.582667 4.5 20.75 51 N60 3.582667 -4.5 20.75 52 N61 3.332667 0 20.75 53 N62 3.582667 0 9.25 54 N63 3.582667 4.5 9.25 55 N64 3.582667 -4.5 9.25 56 N65 3.332667 0 9.25 57 N66 0 -5.75 15 58 N67 1.2 0 14.75 59 N68 1.2 5 15.25 60 N69 1.2 5 14.75 61 N70 1.2 0 15 62 N71 1.2 -5 15.25 63 N72 1.2 -5 14.75 64 N73 2.85 0 15 Nol RISA-3D Version 22 [ Mount.r3d ] Page 4 Company :TEP Designer :AJ Job Number :TEP No. 272252.1169408 Model Name:CLL03413 (10086996) CITY OF SANTA ANA Planning and Building Agency 10/21 /2025 18:42 PM ApproV edS ML IVIQJICI ILI. I ahel I Nnde .I Nnde RntatP(deal SPrtinn/Shane Tvne nesian List (Material nesion Rule 1 FF-1 FF1 FF2 Face Horizontal None None I A53 Gr.B Typical 2 K-1 N41 N32 Kicker None None 3 MP-1 N45A N46A Mount Pie None None A53 Gr.B Typical 4 MP-2 N23 N24 Mount Pie 2.5 None None A53 Gr.B Typical 5 MP-4 N51 N52 Mount Pie None None A53 Gr.B Typical 6 MP-3 N27 N28 Mount Pie None None A53 Gr.6 Typical 7 M10 N19 SF1-3 RIGID None None RIGID Typical 8 M13 N22 N25 RIGID None None RIGID TVpical 9 M15 N26 N29 RIGID None None RIGID TVpical 10 M23A N47A N44A RIGID None None RIGID TVpical 11 M26 N53 N50A RIGID None None RIGID Typical 12 SH-1 SF1-1 SF1-3 Support Horizontal None None A500 Gr. B Rect Typical 13 SV-1 SF1-V3A SF1-V3B Support Vertical None None A53 Gr.B Typical 14 M14 N30 N33 RIGID None None RIGID TVpical 15 M16 N30 N31 RIGID None None RIGID Typical 16 RRU-1 N35 N37 350 RRU Pie None None A53 Gr.B Typical 17 RRU-2 N34 N36 350 RRU Pie None None A53 Gr.B TVpical 18 FF-2 N38 N39 Face Horizontal None None A53 Gr.B TVpical 19 K-2 N73 N66 Kicker None None A53 Gr.B Typical 20 MP-5 N63 N64 Mount Pie None None A53 Gr.B TVpical 21 MP-6 N48 N49 Mount Pie None None A53 Gr.B Typical 22 MP-8 N59 N60 Mount Pie None None A53 Gr.6 Typical 23 RRU-3 N69 N72 RRU Pie None None A53 Gr.B Typical 24 M25 N70 N46 RIGID None None RIGID Typical 25 MP-7 N55 N56 Mount Pie 2.5 None None A53 Gr.B TVpical 26 M28 N45 N42 RIGID None None RIGID Typical 27 M29 N47 N50 RIGID None None RIGID Typical 28 M30 N54 N57 RIGID None None RIGID TVpical 29 M31 N70 N67 RIGID None None RIGID Typical 30 RRU-4 N68 N71 RRU Pie None None A53 Gr.B TVpical 31 M33 N65 N62 RIGID None None RIGID Typical 1321 M34 N61 N58 RIGID None None RIGID T ical 33 SH-2 N40 N42 Su ort Horizontal None None A500 Gr. B Rect T ical 34 SV-2 I N43 I N44 I I SupportVertical I None I None A53 Gr.6 T ical Member Advanced Data I ihpl I RPIeasP .l RPIPase Cnl-Wall Vert RPIP.aRP. Phvsiral neflPrtinn Ratin Ontinns Seismir, nR 1 FF-1 Yes ** NA ** None 2 K-1 BenPIN BenPIN Yes ** NA ** None 3 MP-1 Yes ** NA ** None 4 MP-2 Yes ** NA ** None 5 MP-4 Yes ** NA ** None 6 MP-3 Yes ** NA ** None 7 M10 Yes ** NA ** None 8 M13 Yes ** NA ** None 9 M15 Yes ** NA ** None 10 M23A Yes ** NA ** None 11 M26 Yes * NA ** None 12 SH-1 Yes ** NA ** None 13 SV-1 Yes ** NA ** None 14 M14 Yes ** NA ** None 15 M16 Yes ** NA ** None 16 RRU-1 Yes ** NA ** None 17 RRU-2 Yes ** NA ** None CE I RISA-3D Version 22 [ Mount.r3d ] Page 5 Company :TEP Designer :AJ Job Number :TEP No. 272252.1169408 Model Name:CLL03413 (10086996) CITY OF SANTA ANA Planning and Building Agency 10/21 /2025 18:42 PM ApproV edS Lahel I RPIPasP .I Release Cnl-Wall Vert RPIPasP Phvsiral Deflection Ratid G3ntions v Seismic DR 18 FF-2 Yes* NA *t None 19 K-2 BenPIN BenPIN Yes *" NA 20 MP-5 Yes `* NA None 21 MP-6 Yes" NA ** None 22 MP-8 Yes '* NA ** None 23 RRU-3 Yes `* NA None 24 M25 Yes ** NA ** None 25 MP-7 Yes " NA ` None 26 M28 Yes * NA None 27 M29 Yes ** NA None 28 M30 Yes * NA ` None 29 M31 Yes " NA `* None 30 RRU-4 Yes NA * None 31 M33 Yes "* NA * None 32 M34 Yes NA * None 33 SH-2 Yes ** NA ** None 34 SV-2 Yes * NA None Hot Rolled Steel Design Parameters Label Shane LPnath tftl Lb v-v fftl Lb z-z fftl K v-v K z-z Channel Conn. a fftl Function 1 FF-1 Face Horizontal 12.5 6.25 6.25 2.1 2.1 N/A N/A Lateral 2 K-1 Kicker 6.418 1 1 N/A N/A Lateral 3 MP-1 Mount Pie 9 Segment Segment 2.1 2.1 N/A N/A Lateral 4 MP-2 Mount Pie 2.5 10 Segment Segment 2.1 2.1 N/A N/A Lateral 5 MP-4 Mount Pie 9 Segment Segment 2.1 2.1 N/A N/A Lateral 6 MP-3 Mount Pie 9 Segment Segment 2.1 2.1 N/A N/A Lateral 7 SH-1 Support Horizontal 3 2.1 2.1 N/A N/A Lateral 8 SV-1 Support Vertical 1.25 Segment Segment 2.1 2.1 N/A N/A Lateral 9 RRU-1 RRU Pie 10 Segment Segment 2.1 2.1 N/A N/A Lateral 10 RRU-2 RRU Pie 10 Segment Segment 2.1 2.1 N/A N/A Lateral 11 FF-2 Face Horizontal 12.5 6.25 6.25 2.1 2.1 N/A N/A Lateral 12 K-2 Kicker 6A18 1 1 N/A N/A Lateral 131 MP-5 Mount Pie 9 Segment Segment 2.1 2.1 N/A N/A Lateral 14 MP-6 Mount Pie 9 Se ment Segment 2.1 2.1 N/A N/A Lateral 15 MP-8 Mount Pie 9 Se ment Se ment 2.1 2.1 N/A N/A Lateral 16 RRU-3 RRU Pie 10 Segment Segment 2.1 2.1 N/A N/A Lateral 17 MP-7 Mount Pie 2.5 10 Segment Segment 2.1 2.1 N/A N/A Lateral 18 RRU-4 RRU Pie 10 Segment Segment 2.1 2.1 N/A N/A Lateral 19 SH-2 Support Horizontal 3 2.1 2.1 N/A N/A Lateral 20 SV-2 Support Vertical 1.25 Segment Segment 2.1 2.1 N/A N/A Lateral Basic Load Cases RI C. Desrrintion Cateaory X Gravity Y Gravity 7 Gravity Nndal Point Distrihuted 1 Dead None -1 29 2 0 Wind - No Ice None 29 20 3 30 Wind - No Ice None 58 40 4 45 Wind - No Ice None 58 40 5 60 Wind - No Ice None 58 40 6 90 Wind - No Ice None 29 20 7 120 Wind - No Ice None 58 40 8 135 Wind - No Ice None 58 40 9 150 Wind - No Ice None 58 40 10 180 Wind - No Ice None 29 20 Nol RISA-3D Version 22 [ Mount.r3d ] Page 6 Company :TEP Designer :AJ Job Number :TEP No. 272252.1169408 Model Name:CLL03413 (10086996) CITY OF SANTA ANA Planning and Building Agency 10/21 /2025 18:42 PM ApproV edS Lj RI C Descrintinn Catennry X Gravity Y Gravity 7 Gravity Nndal r.Point v Distrihuted 11 210 Wind - No Ice None 58 � U 40,-. 12 225 Wind - No Ice None 58 40 13 240 Wind - No Ice None 58 40 14 270 Wind - No Ice None 29 20 15 300 Wind - No Ice None 58 40 16 315 Wind - No Ice None 58 40 17 330 Wind - No Ice None 58 40 18 Ice Weight None 29 20 19 0 Wind - Ice None 29 20 20 30 Wind - Ice None 58 40 21 45 Wind - Ice None 58 40 22 60 Wind - Ice None 58 40 23 90 Wind - Ice None 29 20 24 120 Wind - Ice None 58 40 25 135 Wind - Ice None 58 40 26 150 Wind - Ice None 58 40 27 180 Wind - Ice None 29 20 28 210 Wind - Ice None 58 40 29 225 Wind - Ice None 58 40 30 240 Wind - Ice None 58 40 31 270 Wind - Ice None 29 20 32 300 Wind - Ice None 58 40 33 315 Wind - Ice None 58 40 34 330 Wind - Ice None 58 40 35 Lm None 2 36 Lv None 2 37 Seismic Load X ELX -1 29 38 Seismic Load Z ELZ -1 29 Load Combinations Descriotion Solve P-Delta BLC Factor BLC Factor BLC Factor 1 1 AD Yes Y 1 1.4 2 0.9D+1.0 0-Wind Yes Y 1 0.9 2 1 3 0.9D+1.0 30-Wind Yes Y 1 0.9 3 1 4 0.9D+1.0 45-Wind Yes Y 1 0.9 4 1 5 0.9D+1.0 60-Wnd Yes Y 1 0.9 5 1 6 0.9D+1.0 90-Wind Yes Y 1 0.9 6 1 7 0.9D+1.0120-Wind Yes Y 1 0.9 7 1 8 0.9D+1.0135-Wind Yes Y 1 0.9 8 1 9 0.9D+1.0150-Wind Yes Y 1 0.9 9 1 10 0.9D+1.0180-Wind Yes Y 1 0.9 10 1 11 0.9D+1.0 210-Wind Yes Y 1 0.9 11 1 12 0.9D+1.0 225-Wind Yes Y 1 0.9 12 1 13 0.9D+1.0 240-Wind Yes Y 1 0.9 13 1 14 0.9D+1.0 270-Wind Yes Y 1 0.9 14 1 15 0.9D+1.0 300-Wind Yes Y 1 0.9 15 1 16 0.9D+1.0 315-Wind Yes Y 1 0.9 16 1 17 0.9D+1.0 330-Wind Yes Y 1 0.9 17 1 18 1.2D+1.0 0-Wind Yes Y 1 1.2 2 1 19 1.2D+1.0 30-Wind Yes Y 1 1.2 3 1 20 1.2D+1.0 45-Wind Yes Y 1 1.2 4 1 21 1.2D+1.0 60-Wind Yes Y 1 1.2 5 1 22 1.2D+1.0 90-Wind Yes Y 1 1.2 6 1 23 1.2D+1.0120-Wind Yes Y 1 1.2 7 1 24 1.2D+1.0135-Wind Yes Y 1 1.2 8 1 Nol RISA-3D Version 22 [ Mount.r3d ] Page 7 Company :TEP Designer :AJ Job Number :TEP No. 272252.1169408 Model Name:CLL03413 (10086996) CITY OF SANTA ANA Planning and Building Agency 10/21 /2025 18:42 PM ApprovedS Description Solve P-Delta BLC Factor BLCI nS,Actor $L. C Eactor 25 1.2D+1.0150-Wind Yes Y 1 1.2 9 1 26 1.2D+1.0180-Wind Yes Y 1 1.2 10 27 1.2D+1.0 210-Wind Yes Y 1 1.2 11 1 28 1.2D+1.0 225-Wind Yes Y 1 1.2 12 1 29 1.2D+1.0 240-Wind Yes Y 1 1.2 13 1 30 1.2D+1.0 270-Wind Yes Y 1 1.2 14 1 31 1.2D+1.0 300-Wind Yes Y 1 1.2 15 1 32 1.2D+1.0 315-Wind Yes Y 1 1.2 16 1 33 1.2D+1.0 330-Wind Yes Y 1 1.2 17 1 34 1.2D+1.ODi+1.0 0-Wind Ice Y 1 1.2 18 1 19 1 35 1.2D+1.ODi+1.0 30-Wind Ice Y 1 1.2 18 1 20 1 36 1.2D+1.ODi+1.0 45-Wind Ice Y 1 1.2 18 1 21 1 37 1.2D+1.ODi+1.0 60-Wind Ice Y 1 1.2 18 1 22 1 38 1.2D+1.ODi+1.0 90-Wind Ice Y 1 1.2 18 1 23 1 39 1.2D+1.ODi+1.0 120-Wind Ice Y 1 1.2 18 1 24 1 40 1.2D+1.ODi+1.0 135-Wind Ice Y 1 1.2 18 1 25 1 41 1.2D+1.ODi+1.0 150-Wind Ice Y 1 1.2 18 1 26 1 42 1.2D+1.ODi+1.0 180-Wind Ice Y 1 1.2 18 1 27 1 43 1.2D+1.ODi+1.0 210-Wind Ice Y 1 1.2 18 1 28 1 44 1.2D+1.ODi+1.0 225-Wind Ice Y 1 1.2 18 1 29 1 45 1.2D+1.ODi+1.0 240-Wind Ice Y 1 1.2 18 1 30 1 46 1.2D+1.ODi+1.0 270-Wind Ice Y 1 1.2 18 1 31 1 47 1.2D+1.ODi+1.0 300-Wind Ice Y 1 1.2 18 1 32 1 48 1.2D+1.ODi+1.0 315-Wind Ice Y 1 1.2 18 1 33 1 49 1.2D+1.ODi+1.0 330-Wind Ice Y 1 1.2 18 1 34 1 50 1.2D+1.5Lv Yes Y 36 1.5 1 1.2 51 1.2D+1.5Lm+1.0 O-Wind Yes Y 1 1.2 2 0.1 35 1.5 52 1.2D+1.5Lm+1.0 30-Wind Yes Y 1 1.2 3 0.1 35 1.5 53 1.2D+1.5Lm+1.0 45-Wind Yes Y 1 1.2 4 0.1 35 1.5 54 1.2D+1.5Lm+1.0 60-Wind Yes Y 1 1.2 5 0.1 35 1.5 55 1.2D+1.5Lm+1.0 90-Wind Yes Y 1 1.2 6 0.1 35 1.5 56 1.2D+1.5Lm+1.0120-Wind Yes Y 1 1.2 7 0.1 35 1.5 57 1.2D+1.5Lm+1.0135-Wind Yes Y 1 1.2 8 0.1 35 1.5 58 1.2D+1.5Lm+1.0150-Wind Yes Y 1 1.2 9 0.1 35 1.5 59 1.2D+1.5Lm+1.0180-Wind Yes Y 1 1.2 10 0.1 35 1.5 60 1.2D+1.5Lm+1.0 210-Wind Yes Y 1 1.2 11 0.1 35 1.5 61 1.2D+1.5Lm+1.0 225-Wind Yes Y 1 1.2 12 0.1 35 1.5 62 1.2D+1.5Lm+1.0 240-Wind Yes Y 1 1.2 13 0.1 35 1.5 63 1.2D+1.5Lm+1.0 270-Wind Yes Y 1 1.2 14 0.1 35 1.5 64 1.2D+1.5Lm+1.0 300-Wind Yes Y 1 1.2 15 0.1 35 1.5 65 1.2D+1.5Lm+1.0 315-Wind Yes Y 1 1.2 16 0.1 35 1.5 66 1.2D+1.5Lm+1.0 330-Wind Yes Y 1 1.2 17 0.1 35 1.5 67 1.2+0.2Sds D+1.0 0 Seismic Yes Y 1 1.405 ELX 0.511 68 1.2+0.2Sds D+1.0 30 Seismic Yes Y 1 1.405 ELX 0.443 ELZ 0.256 69 1.2+0.2Sds D+1.0 45 Seismic Yes Y 1 1.405 ELX 0.362 ELZ 0.362 70 1.2+0.2Sds D+1.0 60 Seismic Yes Y 1 1.405 ELX 0.256 ELZ 0.443 71 1.2+0.2Sds D+1.0 90 Seismic Yes Y 1 1.405 ELZ 0.511 72 1.2+0.2Sds D+1.0 120 Seismic Yes Y 1 1.405 ELX -0.256 ELZ 0.443 73 1.2+0.2Sds D+1.0 135 Seismic Yes Y 1 1.405 ELX -0.362 ELZ 0.362 74 1.2+0.2Sds D+1.0 150 Seismic Yes Y 1 1.405 ELX -0.443 ELZ 0.256 75 1.2+0.2Sds D+1.0 180 Seismic Yes Y 1 1.405 ELX -0.511 76 1.2+0.2Sds D+1.0 210 Seismic Yes Y 1 1.405 ELX -0.443 ELZ -0.256 77 1.2+0.2Sds D+1.0 225 Seismic Yes Y 1 1.405 ELX -0.362 ELZ -0.362 78 1.2+0.2Sds D+1.0 240 Seismic Yes Y 1 1.405 ELX -0.256 ELZ -0.443 79 1.2+0.2Sds D+1.0 270 Seismic Yes Y 1 1.405 ELZ -0.511 CE RISA-3D Version 22 [ MountAd ] Page 8 Company :TEP Designer :AJ Job Number :TEP No. 272252.1169408 Model Name:CLL03413 (10086996) CITY OF SANTA ANA Planning and Building Agency 10/21 /2025 18:42 PM ApprovedS Description Solve P-Delta BLC Factor BLCI r-,T,wtor BLC Factor 80 1.2+0.2Sds D+1.0 300 Seismic Yes Y 1 1.405 ELX 0.256 ELZ -0.44:5 81 1.2+0.2Sds D+1.0 315 Seismic Yes Y 1 1.405 ELX 82 1.2+0.2Sds D+1.0 330 Seismic Yes Y 1 1.405 ELX 0.443 ELZ -0.256 83 0.9-0.2Sds *DL+1.0 0 Seismic Yes Y 1 0.695 ELX 0.511 84 0.9-0.2Sds *DL+1.0 30 Seismic Yes Y 1 0.695 ELX 0.443 ELZ 0.256 85 0.9-0.2Sds *DL+1.0 Seismic Yes Y 1 0.695 ELX 0.362 ELZ 0.362 86 0.9-0.2Sds *DL+1.0 60 Seismic Yes Y 1 0.695 ELX 0.256 ELZ 0.443 87 0.9-0.2Sds *DL+1.0 90 Seismic Yes Y 1 0.695 ELZ 0.511 88 0.9-0.2Sds *DL+1.0 120 Seismic Yes Y 1 0.695 ELX -0.256 ELZ 0.443 89 0.9-0.2Sds *DL+1.0 135 Seismic Yes Y 1 0.695 ELX -0.362 ELZ 0.362 90 0.9-0.2Sds *DL+1.0 150 Seismic Yes Y 1 0.695 ELX -0.443 ELZ 0.256 91 0.9-0.2Sds *DL+1.0 180 Seismic Yes Y 1 0.695 ELX -0.511 92 0.9-0.2Sds *DL+1.0 210 Seismic Yes Y 1 0.695 ELX -0.443 ELZ -0.256 93 0.9-0.2Sds *DL+1.0 225 Seismic Yes Y 1 0.695 ELX -0.362 ELZ -0.362 94 0.9-0.2Sds *DL+1.0 240 Seismic Yes Y 1 0.695 ELX -0.256 ELZ -0.443 95 0.9-0.2Sds *DL+1.0 270 Seismic Yes Y 1 0.695 ELZ -0.511 96 0.9-0.2Sds *DL+1.0 300 Seismic Yes Y 1 0.695 ELX 0.256 ELZ -0.443 97 0.9-0.2Sds *DL+1.0 315 Seismic Yes Y 1 0.695 ELX 0.362 ELZ -0.362 98 0.9-0.2Sds *DL+1.0 330 Seismic Yes Y 1 0.695 ELX 0.443 ELZ -0.256 Load Combination Design Description Service Hot Rolled Cold Formed Wood Concrete Masonry Aluminum Stainless Connection 1 1.4D Yes Yes Yes Yes Yes Yes Yes Yes 2 0.9D+1.0 0-Wind Yes Yes Yes Yes Yes Yes Yes Yes 3 0.9D+1.0 30-Wind Yes Yes Yes Yes Yes Yes Yes Yes 4 0.9D+1.0 45-Wind Yes Yes Yes Yes Yes Yes Yes Yes 5 0.9D+1.0 60-Wind Yes Yes Yes Yes Yes Yes Yes Yes 6 0.9D+1.0 90-Wind Yes Yes Yes Yes Yes Yes Yes Yes 7 0.9D+1.0120-Wind Yes Yes Yes Yes Yes Yes Yes Yes 8 0.9D+1.0135-Wind Yes Yes Yes Yes Yes Yes Yes Yes 9 0.9D+1.0150-Wind Yes Yes Yes Yes Yes Yes Yes Yes 10 0.9D+1.0180-Wind Yes Yes Yes Yes Yes Yes Yes Yes 11 0.9D+1.0 210-Wind Yes Yes Yes Yes Yes Yes Yes Yes 121 0.9D+1.0 225-Wind Yes Yes Yes Yes Yes Yes Yes Yes 13 0.9D+1.0 240-Wind Yes Yes Yes Yes Yes Yes Yes Yes 14 0.9D+1.0 270-Wind Yes Yes Yes Yes Yes Yes Yes Yes 15 0.9D+1.0 300-Wind Yes Yes Yes Yes Yes Yes Yes Yes 16 0.9D+1.0 315-Wind Yes Yes Yes Yes Yes Yes Yes Yes 17 0.9D+1.0 330-Wind Yes Yes Yes Yes Yes Yes Yes Yes 18 1.2D+1.0 0-Wind Yes Yes Yes Yes Yes Yes Yes Yes 19 1.2D+1.0 30-Wind Yes Yes Yes Yes Yes Yes Yes Yes 20 1.2D+1.0 45-Wind Yes Yes Yes Yes Yes Yes Yes Yes 21 1.2D+1.0 60-Wind Yes Yes Yes Yes Yes Yes Yes Yes 22 1.2D+1.0 90-Wind Yes Yes Yes Yes Yes Yes Yes Yes 23 1.2D+1.0120-Wind Yes Yes Yes Yes Yes Yes Yes Yes 24 1.2D+1.0135-Wind Yes Yes Yes Yes Yes Yes Yes Yes 25 1.2D+1.0150-Wind Yes Yes Yes Yes Yes Yes Yes Yes 26 1.2D+1.0180-Wind Yes Yes Yes Yes Yes Yes Yes Yes 27 1.2D+1.0 210-Wind Yes Yes Yes Yes Yes Yes Yes Yes 28 1.2D+1.0 225-Wind Yes Yes Yes Yes Yes Yes Yes Yes 29 1.2D+1.0 240-Wind Yes Yes Yes Yes Yes Yes Yes Yes 30 1.2D+1.0 270-Wind Yes Yes Yes Yes Yes Yes Yes Yes 31 1.2D+1.0 300-Wind Yes Yes Yes Yes Yes Yes Yes Yes 32 1.2D+1.0 315-Wind Yes Yes Yes Yes Yes Yes Yes Yes 33 1.2D+1.0 330-Wind Yes Yes Yes Yes Yes Yes Yes Yes CE RISA-3D Version 22 [ Mount.r3d ] Page 9 Company :TEP Designer :AJ Job Number :TEP No. 272252.1169408 Model Name:CLL03413 (10086996) CITY OF SANTA ANA Planning and Building Agency 10/21 /2025 18:42 PM ApproV edS Description Service Hot Rolled Cold Formed Wood Concrete Masonry Al$rhgygi Stainless Connection 34 1.2D+1.ODi+1.0 0-Wind Ice Yes Yes Yes Yes Yes I Yes Yes Yes 35 1.2D+1.ODi+1.0 30-Wind Ice Yes Yes Yes Yes Yes 36 1.2D+1.ODi+1.0 45-Wind Ice Yes Yes Yes Yes Yes Yes Yes Yes 37 1.2D+1.ODi+1.0 60-Wind Ice Yes Yes Yes Yes Yes Yes Yes Yes 38 1.2D+1.ODi+1.0 90-Wind Ice Yes Yes Yes Yes Yes Yes Yes Yes 39 1.2D+1.ODi+1.0 120-Wind Ice Yes Yes Yes Yes Yes Yes Yes Yes 40 1.2D+1.ODi+1.0 135-Wind Ice Yes Yes Yes Yes Yes Yes Yes Yes 41 1.2D+1.ODi+1.0 150-Wind Ice Yes Yes Yes Yes Yes Yes Yes Yes 42 1.2D+1.ODi+1.0 180-Wind Ice Yes Yes Yes Yes Yes Yes Yes Yes 43 1.2D+1.ODi+1.0 210-Wind Ice Yes Yes Yes Yes Yes Yes Yes Yes 44 1.2D+1.ODi+1.0 225-Wind Ice Yes Yes Yes Yes Yes Yes Yes Yes 45 1.2D+1.ODi+1.0 240-Wind Ice Yes Yes Yes Yes Yes Yes Yes Yes 46 1.2D+1.ODi+1.0 270-Wind Ice Yes Yes Yes Yes Yes Yes Yes Yes 47 1.2D+1.ODi+1.0 300-Wind Ice Yes Yes Yes Yes Yes Yes Yes Yes 48 1.2D+1.ODi+1.0 315-Wind Ice Yes Yes Yes Yes Yes Yes Yes Yes 49 1.2D+1.ODi+1.0 330-Wind Ice Yes Yes Yes Yes Yes Yes Yes Yes 50 1.2D+1.5Lv Yes Yes Yes Yes Yes Yes Yes Yes 51 1.2D+1.5Lm+1.0 0-Wind Yes Yes Yes Yes Yes Yes Yes Yes 52 1.2D+1.5Lm+1.0 30-Wind Yes Yes Yes Yes Yes Yes Yes Yes 53 1.2D+1.5Lm+1.0 45-Wind Yes Yes Yes Yes Yes Yes Yes Yes 54 1.2D+1.5Lm+1.0 60-Wind Yes Yes Yes Yes Yes Yes Yes Yes 55 1.2D+1.5Lm+1.0 90-Wind Yes Yes Yes Yes Yes Yes Yes Yes 56 1.2D+1.5Lm+1.0120-Wind Yes Yes Yes Yes Yes Yes Yes Yes 57 1.2D+1.5Lm+1.0135-Wind Yes Yes Yes Yes Yes Yes Yes Yes 58 1.2D+1.5Lm+1.0150-Wind Yes Yes Yes Yes Yes Yes Yes Yes 59 1.2D+1.5Lm+1.0180-Wind Yes Yes Yes Yes Yes Yes Yes Yes 60 1.2D+1.5Lm+1.0 210-Wind Yes Yes Yes Yes Yes Yes Yes Yes 61 1.2D+1.5Lm+1.0 225-Wind Yes Yes Yes Yes Yes Yes Yes Yes 62 1.2D+1.5Lm+1.0 240-Wind Yes Yes Yes Yes Yes Yes Yes Yes 63 1.2D+1.5Lm+1.0 270-Wind Yes Yes Yes Yes Yes Yes Yes Yes 64 1.2D+1.5Lm+1.0 300-Wind Yes Yes Yes Yes Yes Yes Yes Yes 65 1.2D+1.5Lm+1.0 315-Wind Yes Yes Yes Yes Yes Yes Yes Yes 66 1.2D+1.5Lm+1.0 330-Wind Yes Yes Yes Yes Yes Yes Yes Yes 67 1.2+0.2Sds D+1.0 0 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 68 1.2+0.2Sds D+1.0 30 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 69 1.2+0.2Sds D+1.0 45 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 70 1.2+0.2Sds D+1.0 60 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 71 1.2+0.2Sds D+1.0 90 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 72 1.2+0.2Sds D+1.0 120 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 73 1.2+0.2Sds D+1.0 135 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 74 1.2+0.2Sds D+1.0 150 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 75 1.2+0.2Sds D+1.0 180 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 76 1.2+0.2Sds D+1.0 210 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 77 1.2+0.2Sds D+1.0 225 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 78 1.2+0.2Sds D+1.0 240 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 79 1.2+0.2Sds D+1.0 270 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 80 1.2+0.2Sds D+1.0 300 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 81 1.2+0.2Sds D+1.0 315 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 82 1.2+0.2Sds D+1.0 330 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 83 0.9-0.2Sds *DL+1.0 0 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 84 0.9-0.2Sds *DL+1.0 30 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 85 0.9-0.2Sds *DL+1.0 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 86 0.9-0.2Sds *DL+1.0 60 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 87 0.9-0.2Sds *DL+1.0 90 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 88 0.9-0.2Sds *DL+1.0 120 Seismic Yes Yes Yes Yes Yes Yes Yes Yes Nol RISA-3D Version 22 [ Mount.r3d ] Page 10 Company :TEP Designer :AJ Job Number :TEP No. 272252.1169408 Model Name:CLL03413 (10086996) CITY OF SANTA ANA Planning and Building Agency 10/21 /2025 18:42 PM ApprovedS DPsrrintinn Service Hnt Rnlled Cold Fnrmed Wond Cnncrete Masnnry Cnnneetinn 89 0.9-0.2Sds *DL+1.0 135 Seismic Yes Yes Yes Yes Yes I Yes 90 0.9-0.2Sds *DL+1.0 150 Seismic Yes Yes Yes Yes Yes YQR 91 0.9-0.2Sds *DL+1.0 180 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 92 0.9-0.2Sds *DL+1.0 210 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 93 0.9-0.2Sds *DL+1.0 225 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 94 0.9-0.2Sds *DL+1.0 240 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 95 0.9-0.2Sds *DL+1.0 270 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 96 0.9-0.2Sds *DL+1.0 300 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 97 0.9-0.2Sds *DL+1.0 315 Seismic Yes Yes Yes Yes Yes Yes Yes Yes 98 0.9-0.2Sds *DL+1.0 330 Seismic I Yes Yes Yes Yes Yes Yes Yes Yes Node Loads and Enforced Displacements (BLC 35 : Lm) Node Label L. D. M Direction Maanitude R. k-ft). (in. rad). (k*s2/ft. k*sz*ft)l Node Loads and Enforced Displacements (BLC 36 : Lv) Node Label L, D, M Direction Maqnitude f(k, k-ft), (in, rad), (k*sz/ft, k*sz*ft)l Member Area Loads No Data to Print... Envelope Node Reactions NndP I ahel X rkl I C Y rkl I C 7 fkl I C MX fk-ftl I C MY fk-ftl I C M7 fk-ftl I C 1 SF1-1 max 1.2 2 0.37 67 1.1 23 2.247 50 3.014 12 0.32 26 2 min -2.037 26 -0.095 59 -0.942 13 -0.336 95 -3.067 20 -0.382 50 3 N32 max 0.846 59 1.75 59 -0.042 84 0.024 61 0.049 61 0.004 4 4 min 0.245 83 0.498 83 -0.15 62 -0.022 4 -0.045 4 -0,004 61 5 N40 max 1.156 2 0.333 67 0.986 23 2.242 50 2.838 29 0.293 26 6 min -1.997 26 0.004 91 -0.989 29 -0.422 79 -2.765 7 0.059 2 7 N66 max 0.763 59 1.555 59 0.016 6 0.024 62 0.048 62 0 98 8 min 0.252 83 0.505 83 -0.016 14 -0.021 23 -0.042 23 0 1 191 Totals: I max 1 3.048 1 18 1 3.279 1 58 1 2.017 1 23 1101 1 min 1 -2.961 1 10 1 1.465 1 95 1 -2.028 1 29 Envelope A/SC 15TH (360-16): LRFD Member Steel Code Checks Member Shane Code Check Locfftl LC Shear CheckLocfftl Dir LC ohi*Pnc fklohi*Pnt fklohi*Mn v-v fk-ftlohi*Mn z-z fk-ftl Cb Eon 1 1 FF-1 PIPE 3.0 0.621 6.25 50 0.086 6.25 18 25.929 65.205 5.749 5.749 1 H1-1b 2 FF-2 PIPE 3.0 0.606 6.25 50 0.086 6.25 18 25.929 65.205 5.749 5.749 1 H1-1b 3 MP-6 PIPE 2.0 0.273 4.5 26 0.018 4.5 26 11.015 32.13 1.872 1.872 1 H1-1b 4 MP-3 PIPE 2.0 0.273 4.5 26 0.018 4.5 26 11.015 32.13 1.872 1.872 1 H1-1b 5 SH-1 HSS4X4X3 0.264 0 28 0.255 2.875 50 91.044 106.812 12.662 12.662 2.163 H1-1b 6 MP-8 PIPE 2.0 0.256 4.5 26 0.017 4.5 26 11.015 32.13 1.872 1.872 1 H1-1b 7 MP-1 PIPE 2.0 0.256 4.5 18 0.017 4.5 1 126 11.015 1 32.13 1.872 1.872 1 1-11-1b 8 SH-2 HSS4X4X3 0.247 0 29 0.251 2.875 50 91.044 106.812 12.662 12.662 .426 H1-1b 9 RRU-2 PIPE 2. 0.235 5 26 0.023 5 26 8.922 32.13 1.872 1.872 1 H1-1b 10 RRU-3 PIPE 2.0 0.186 5 26 0.021 5 26 8.922 32.13 1.872 1.872 1 H1-1b 11 MP-4 PIPE 2.0 0.165 4.5 28 0.011 4.5 28 11.015 32.13 1.872 1.872 1 H1-1b CE RISA-3D Version 22 [ MountAd ] Page 11 CITY OF SANTA ANA Planning and Building Agency Company :TEP 10/21/2025 Designer :AJ �/ 18:42 PM Job Number :TEP No. 272252.1169408 AppaWeAS Model Name:CLL03413 (10086996) FOR PERMIT ISSUA Member Shape Code CheckLoc[ft] LC Shear CheckLoc[ft] Dir LC phi*Pnc [k]phi*Pnt [k]phi*Mn y-y [k-ftMi1 A/In z-z [k-ft] Cb Eqn 121 MP-5 PIPE 2.0 0.164 4.5 28 0.011 4.5 12 11.015 32.13 1.872 9.872 1 H1-1b 13 RRU-1 PIPE 2.0 0.152 5 26 0.013 5 26 8.922 32.13 1.872 14 RRU-4 PIPE 2.0 0.152 5 26 0.013 5 26 8.922 32.13 1.872 1.872 1 H1-1b 15 K-1 PIPE 2.0 0.099 6.41859 0.034 6.418 61 19.609 32.13 1.872 1.872 1 H1-1b 16 MP-2 PIPE 2.5 0.095 5 18 0.01 5 18 20.573 50.715 3.596 3.596 1 H1-1b 17 MP-7 PIPE 2.5 0.095 5 18 0.01 5 18 20.573 50.715 3.596 3.596 1 H1-1b 18 K-2 PIPE 2.0 0.088 6.418 59 0.033 6.418 62 19.609 32.13 1.872 1.872 1 H1-1b 19 SV-1 PIPE 4.0 0 10.6251821 0 0.625 22 92.728 93.24 10.631 10.631 1 H1-1b 20 SV-2 PIPE 4.0 0 0.625 82 0 0.625 30 92.728 93.24 10.6311 10.631 1 H1-1b* CE RISA-3D Version 22 [ Mount.r3d ] Page 12 October 21, 2025 T-Arm Mount Analysis Main / Dyer (CLL03413) TEP Project Number 272252.1169408 Page 5 APPENDIX B ADDITIONAL CALCULATIONS ASCE ASCE Hazards Report AMERICAN SOCIETY OF CIVIL ENGINEERS Address: Standard: ASCE/SE17-16 Latitude: 33.7 No Address at This Location Risk Category: II Longitude: -117 Soil Class: D - Default (see Elevation: 46.4 Section 11.4.3) 88) A; A!A.'i, I n W'Warn Av i Santa Ana Wind CITY OF SANTA ANA Planning and Building Agency Approved FOR PERMIT ISSUANCE 11732 69806 3 M/Rffld!6W56 ft (NAVD Date: Ir - Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-113 and Figs. CC.2-1—CC.2-4, and Section 26.5.2 Date Accessed: Mon Oct 13 2025 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane -prone region as defined in ASCE/SEI 7-16 Section 26.2. https://ascehazardtool.org/ Page 1 of 3 Mon Oct 13 2025 ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS Seismic CITY OF SANTA ANA Planning and Building Agency Approved FOR PERMIT ISSUANCE Site Soil Class: D - Default (see Section 11.4.3) Master ID: Results: Date: SS 1.279 SW N/A S, 0.458 T L 8 Fa 1.2 PGA: 0.543 Fv N/A PGA M : 0.652 SMS 1.535 FPGA 1.2 SM, N/A le 1 SoS 1.023 CV 1.356 Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Data Accessed: Mon Oct 13 2025 Date Source: USGS Seismic Design Maps his://ascehazardtool.org/ Page 2 of 3 Mon Oct 13 2025 ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS Ice CITY OF SANTA ANA Planning and Building Agency Approved FOR PERMIT ISSUANCE Results: Master ID: Ice Thickness: 0 in. Date: Concurrent Temperature: 25 F Gust Speed 30 mph Data Source: Standard ASCE/SEI 7-16, Figs. 10-2 through 10-8 Date Accessed: Mon Oct 13 2025 Ice thicknesses on structures in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. Values provided are equivalent radial ice thicknesses due to freezing rain with concurrent 3-second gust speeds, for a 500-year mean recurrence interval, and temperatures concurrent with ice thicknesses due to freezing rain. Thicknesses for ice accretions caused by other sources shall be obtained from local meteorological studies. Ice thicknesses in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. The ASCE Hazard Tool is provided for your convenience, for informational purposes only, and is provided "as is" and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third -party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third -party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE Hazard Tool. his://ascehazardtool.org/ Page 3 of 3 Mon Oct 13 2025 CLL03413 (10086996) TEP No. Analysis By:AJ 10/21/2025 Checked By:SMS 10/21/2025 Code Revisions:IBC 2021 Tower Type:68.0 Ult. Wind Velocity:95 mph Kzt:1.000 Section 2.6.6 Live Load Velocity:30 mph Kd:0.950 Ice Wind Velocity:30 mph Kz-Mount:1.103 Section 2.6.5.2 Base Ice Thickness:0.00 inches Kz-Antenna:1.109 Section 2.6.5.2 Mount Centerline:52.0 ft Kiz:1.048 Section 2.6.10 Antenna Centerline:53.5 ft Ice Thickness:0.000 inches - Section 2.6.10 Exposure Category:C Kes-wind:1.00 Annex S (Table S-1) Topo Category:1 Kes-ice:1.00 Annex S (Table S-1) Risk Category:II Ks:1.000 Section 2.6.7 Ground Elevation:46 ft Ke:0.998 Table 2-6 . (qzGh)Mount:24.17 (qzGh)Mount:2.41 (qzGh)Antenna:24.31 (qzGh)Antenna:2.42 Seismic Code Revisions: Seismic Risk Category: SDS:1.023 Design Short Period Spectral Accel. Ip:1.0 Importance Factor Rp:2.0 Response Modification Factor :1.0 As:1.0 Applification Factor - TIA-222-H Section 2.7.8.1 S1:0.458 Spectral Acceleration at a Period of 1 Second Cs:0.512 kips/kip TIA-H Sec 2.7.7.1.1 Cs-min:0.045 kips/kip TIA-H Sec 2.7.7.1.1 TIA-222-H 272252.1169408 Wind Calculations: TIA-222-H Monopole Wind Inputs: Without Ice - (psf) With Ice - (psf) II Seismic Input Seismic Design Force Universal Force Generator | Version 1.15.3 | Contact: RisaUFG@tepgroup.net CL L 0 3 4 1 3 ( 1 0 0 8 6 9 9 6 ) TE P N o . An a l y s i s B y : Ch e c k e d B y : MF R M o d e l H e i g h t ( i n ) W i d t h ( i n ) D e p t h ( i n ) Wt . ( l b s ) A z i m u t h ° Qt y S h a p e M e m b e r L a b e l L o c . 1 L o c . 2 L o c . 3 F r o n t S i d e F r o n t S i d e K ** CO M M S C O P E J A H H - 6 5 B - R 3 B - V 3 7 2 . 0 0 1 3 . 8 0 8 . 2 0 6 3 . 3 0 0 . 0 0 1 F l a t M P - 4 2 . 5 0 7 . 5 0 3 . 7 3 2 . 6 0 9 0 . 1 4 6 2 . 8 3 1 . 0 KA T H R E I N 8 0 0 1 0 9 6 5 7 8 . 7 0 2 0 . 0 0 6 . 9 0 1 0 8 . 6 0 0 . 0 0 1 F l a t M P - 3 2 . 5 0 7 . 5 0 1 3 . 8 1 5 . 8 3 3 0 0 . 4 3 1 2 6 . 8 7 0 . 9 ** ER I C S S O N A I R 6 4 7 2 B 7 7 G B 7 7 M 3 6 . 4 2 1 6 . 1 4 7 . 4 8 9 2 . 6 1 0 . 0 0 1 F l a t M P - 2 2 . 5 0 3 . 5 0 5 . 1 5 1 . 6 9 1 2 4 . 4 5 4 0 . 8 4 1 . 0 CC I A N T E N N A S T P A 6 5 R - B U 6 D 7 1 . 2 0 2 1 . 0 0 7 . 8 0 7 2 . 5 0 0 . 0 0 1 F l a t M P - 1 2 . 5 0 7 . 5 0 1 2 . 8 7 5 . 6 7 2 7 9 . 9 3 1 2 3 . 3 8 0 . 9 ER I C S S O N 8 8 4 3 B 2 / B 6 6 A 1 4 . 9 0 1 3 . 2 0 1 0 . 9 0 7 2 . 0 0 0 . 0 0 1 F l a t R R U - 1 3 . 5 0 1 . 6 4 1 . 3 5 3 5 . 6 5 2 9 . 4 4 0 . 9 ER I C S S O N 4 4 4 9 B 5 / B 1 2 1 4 . 9 6 1 3 . 1 9 1 0 . 4 3 7 3 . 0 0 0 . 0 0 1 F l a t R R U - 1 3 . 5 0 1 . 6 4 1 . 3 0 3 5 . 7 6 2 8 . 2 8 0 . 9 ER I C S S O N 4 4 7 8 B 1 4 1 8 . 1 0 1 3 . 4 0 8 . 2 6 5 9 . 4 0 0 . 0 0 1 F l a t R R U - 2 3 . 5 0 2 . 0 2 1 . 2 5 4 3 . 9 6 2 7 . 1 0 0 . 9 ER I C S S O N R R U S E 2 B 2 9 2 0 . 4 0 1 8 . 5 0 7 . 5 0 5 2 . 9 0 0 . 0 0 1 F l a t R R U - 2 3 . 5 0 3 . 1 5 1 . 2 9 6 8 . 4 0 2 7 . 9 6 0 . 9 ER I C S S O N R R U S 3 2 B 3 0 2 7 . 2 0 1 2 . 0 5 7 . 0 0 5 2 . 9 0 0 . 0 0 1 F l a t R R U - 2 3 . 5 0 2 . 7 3 1 . 6 7 5 9 . 4 0 3 6 . 2 8 0 . 9 RA Y C A P D C 6 - 4 8 - 6 0 - 1 8 - 8 C - E V 3 1 . 4 0 1 0 . 2 4 1 0 . 2 4 2 6 . 2 0 0 . 0 0 1 R o u n d R R U - 1 1 . 5 0 1 . 1 4 1 . 1 4 2 4 . 8 9 2 4 . 8 9 0 . 9 RA Y C A P D C 6 - 4 8 - 6 0 - 1 8 - 8 C - E V 3 1 . 4 0 1 0 . 2 4 1 0 . 2 4 2 6 . 2 0 0 . 0 0 1 R o u n d R R U - 2 1 . 5 0 1 . 1 4 1 . 1 4 2 4 . 8 9 2 4 . 8 9 0 . 9 ** CO M M S C O P E J A H H - 6 5 B - R 3 B - V 3 7 2 . 0 0 1 3 . 8 0 8 . 2 0 6 3 . 3 0 0 . 0 0 1 F l a t M P - 5 2 . 5 0 7 . 5 0 3 . 7 3 2 . 6 0 9 0 . 1 4 6 2 . 8 3 1 . 0 KA T H R E I N 8 0 0 1 0 9 6 5 7 8 . 7 0 2 0 . 0 0 6 . 9 0 1 0 8 . 6 0 0 . 0 0 1 F l a t M P - 6 2 . 5 0 7 . 5 0 1 3 . 8 1 5 . 8 3 3 0 0 . 4 3 1 2 6 . 8 7 0 . 9 ** ER I C S S O N A I R 6 4 7 2 B 7 7 G B 7 7 M 3 6 . 4 2 1 6 . 1 4 7 . 4 8 9 2 . 6 1 0 . 0 0 1 F l a t M P - 7 2 . 5 0 3 . 5 0 5 . 1 5 1 . 6 9 1 2 4 . 4 5 4 0 . 8 4 1 . 0 CC I A N T E N N A S T P A 6 5 R - B U 6 D 7 1 . 2 0 2 1 . 0 0 7 . 8 0 7 2 . 5 0 0 . 0 0 1 F l a t M P - 8 2 . 5 0 7 . 5 0 1 2 . 8 7 5 . 6 7 2 7 9 . 9 3 1 2 3 . 3 8 0 . 9 ER I C S S O N 8 8 4 3 B 2 / B 6 6 A 1 4 . 9 0 1 3 . 2 0 1 0 . 9 0 7 2 . 0 0 0 . 0 0 1 F l a t R R U - 4 3 . 5 0 1 . 6 4 1 . 3 5 3 5 . 6 5 2 9 . 4 4 0 . 9 ER I C S S O N 4 4 4 9 B 5 / B 1 2 1 4 . 9 6 1 3 . 1 9 1 0 . 4 3 7 3 . 0 0 0 . 0 0 1 F l a t R R U - 4 3 . 5 0 1 . 6 4 1 . 3 0 3 5 . 7 6 2 8 . 2 8 0 . 9 ER I C S S O N 4 4 7 8 B 1 4 1 8 . 1 0 1 3 . 4 0 8 . 2 6 5 9 . 4 0 0 . 0 0 1 F l a t R R U - 3 3 . 5 0 2 . 0 2 1 . 2 5 4 3 . 9 6 2 7 . 1 0 0 . 9 ER I C S S O N R R U S E 2 B 2 9 2 0 . 4 0 1 8 . 5 0 7 . 5 0 5 2 . 9 0 0 . 0 0 1 F l a t R R U - 3 3 . 5 0 3 . 1 5 1 . 2 9 6 8 . 4 0 2 7 . 9 6 0 . 9 ER I C S S O N R R U S 3 2 B 3 0 2 7 . 2 0 1 2 . 0 5 7 . 0 0 5 2 . 9 0 0 . 0 0 1 F l a t R R U - 3 3 . 5 0 2 . 7 3 1 . 6 7 5 9 . 4 0 3 6 . 2 8 0 . 9 RA Y C A P D C 6 - 4 8 - 6 0 - 1 8 - 8 C - E V 3 1 . 4 0 1 0 . 2 4 1 0 . 2 4 2 6 . 2 0 0 . 0 0 1 R o u n d R R U - 4 1 . 5 0 1 . 1 4 1 . 1 4 2 4 . 8 9 2 4 . 8 9 0 . 9 27 2 2 5 2 . 1 1 6 9 4 0 8 A J 1 0 / 2 1 / 2 0 2 5 S M S 1 0 / 2 1 / 2 0 2 5 F a n d C A v a l u e s c a l c u l a t e d i n a c c o r d a n c e w i t h T I A - 2 2 2 - H , u n l e s s o t h e r w i s e n o t e d . Az i m u t h i s t h e a b s o l u t e a n g l e m e a s u r e d c l o c k w i s e f r o m R I S A - 3 D g l o b a l X - a x i s . ** C A v a l u e s a r e d e r i v e d p e r M a n u f a c t u r e r C F D d a t a D i s t a n c e A l o n g M e m b e r ( f t ) C A ( f t ² ) F ( l b s ) Un i v e r s a l F o r c e G e n e r a t o r | V e r s i o n 1 . 1 5 . 3 | C o n t a c t : R i s a U F G @ t e p g r o u p . n e t CLL03413 (10086996) TEP No. Analysis By:AJ 10/21/2025 Checked By:SMS 10/21/2025 Member Forces are Calculated in Accordance with TIA-222-H Member Name Wind Proj. (in) Length (in) Shape (°)Perimeter (in) FF-1 3.500 150.00 Round 90.00 11.00 K-1 2.375 77.01 Round 7.46 MP-1 2.375 108.00 Round 7.46 MP-2 2.875 120.00 Round 9.03 MP-4 2.375 108.00 Round 7.46 MP-3 2.375 108.00 Round 7.46 SH-1 4.000 36.00 Flat 10.00 16.00 SV-1 4.500 15.00 Round 14.14 RRU-1 2.375 120.00 Round 7.46 RRU-2 2.375 120.00 Round 7.46 FF-2 3.500 150.00 Round 90.00 11.00 K-2 2.375 77.01 Round 7.46 MP-5 2.375 108.00 Round 7.46 MP-6 2.375 108.00 Round 7.46 MP-8 2.375 108.00 Round 7.46 RRU-3 2.375 120.00 Round 7.46 MP-7 2.875 120.00 Round 9.03 RRU-5 2.375 120.00 Round 7.46 SH-2 4.000 36.00 Flat 0.00 16.00 SV-2 4.500 15.00 Round 14.14 272252.1169408 Universal Force Generator | Version 1.15.3 | Contact: RisaUFG@tepgroup.net CL L 0 3 4 1 3 ( 1 0 0 8 6 9 9 6 ) TE P N o . An a l y s i s B y : Ch e c k e d B y : Ma n u f a c t u r e r C F D d a t a i s c u r v e - f i t f o r a n a l y s i s u s i n g a p r o p r i e t a r y T E P m e t h o d t o e n s u r e c o n s i d e r a t i o n o f w o r s t - c a s e w i n d d i r e c t i o n i n 1 5 / 3 0 ° i n c r e m e n t s . Th e d a t a b e l o w i s a s u m m a r y o f p r o v i d e d E P A v a l u e s a n d d e r i v e d W i n d F o r c e s f o r a p p l i c a b l e A T & T E q u i p m e n t i n c o r p o r a t i n g T E P S t a n d a r d s . Ma k e M o d e l 0 ° 1 0 ° 2 0 ° 3 0 ° 4 0 ° 5 0 ° 6 0 ° 7 0 ° 8 0 ° 9 0 ° 1 0 0 ° 1 1 0 ° 1 2 0 ° 1 3 0 ° 1 4 0 ° 1 5 0 ° 1 6 0 ° 1 7 0 ° 1 8 0 ° CO M M S C O P E J A H H - 6 5 B - R 3 B - V 3 EP A ( f t - 2 ) : 3. 1 4 . 4 4 . 9 2 5 . 2 5 . 4 2 5 . 1 1 4 . 2 5 3 . 8 1 2 . 7 2 . 6 2 . 7 4 . 3 5 5 . 3 9 6 . 2 4 6 . 4 5 6 . 0 6 5 . 4 9 3 . 5 6 3 . 2 3 Fo r c e ( L b s ) : 90 . 1 4 1 0 6 . 3 3 1 2 2 . 5 2 1 3 8 . 7 1 1 3 6 . 7 8 1 2 3 . 4 9 1 1 0 . 1 9 9 2 . 0 7 6 5 . 2 5 6 2 . 8 3 6 5 . 2 5 1 0 5 . 1 2 1 3 8 . 4 7 1 6 5 . 0 5 1 6 3 . 1 2 1 6 0 . 9 4 1 3 2 . 6 7 8 6 . 0 3 8 9 . 1 7 ER I C S S O N A I R 6 4 7 2 B 7 7 G / M EP A ( f t - 2 ) : 4. 9 4 4 . 8 4 . 4 2 3 . 8 6 3 . 3 3 2 . 9 1 2 . 4 2 1 . 9 4 1 . 5 9 1 . 6 5 1 . 9 5 2 . 1 8 2 . 4 5 2 . 8 3 . 1 3 . 3 1 3 . 4 7 3 . 4 6 3 . 1 Fo r c e ( L b s ) : 12 4 . 4 5 1 1 5 . 9 9 1 0 7 . 7 8 9 9 . 5 6 8 0 . 7 1 7 0 . 3 2 5 9 . 9 3 4 6 . 8 8 3 8 . 4 2 4 0 . 8 4 4 7 . 1 2 5 3 . 4 1 6 0 . 1 7 6 9 . 1 1 7 5 . 1 5 8 7 . 2 4 8 5 . 5 5 8 3 . 6 1 8 4 . 8 2 Wi n d D i r e c t i o n A J 1 0 / 2 1 / 2 0 2 5 S M S 1 0 / 2 1 / 2 0 2 5 27 2 2 5 2 . 1 1 6 9 4 0 8 Un i v e r s a l F o r c e G e n e r a t o r | V e r s i o n 1 . 1 5 . 3 | C o n t a c t : R i s a U F G @ t e p g r o u p . n e t CLL03413 (10086996) TEP No. Analysis By:AJ 10/21/2025 Checked By:SMS 10/21/2025 Moment Bolt Group - Collar Connection Code Revisions: Bolt Type: Bolt Size:0.625 in # Bolts:4 #VALUE! #VALUE! Plate Width:10.00 in Bolt Capacity=15.4%PASS Plate Height:10.00 in Plate Capacity=43.1%PASS Bolt H Gap:7.00 in Bolt V Gap:7.00 in Plate T:0.500 in Slip Member Ø:N/A in Bolt Grade:A325N Fybolt:92.0 ksi Member Shape:Flat Fubolt:120.0 ksi Plate Fy:36.0 ksi r:4.9 in Plate Fu:58.0 ksi J:98.0 in4/in2 Member Height:4.0 in Abolt:0.3 in2 Member Width:4.0 in Abolt, Net Tensile:0.2 in2 Pretension:19.0 kips Capacities: 272252.1169408 ANSI/TIA-222-H Headed Bolts Connection Inputs: Member Properties:Bolt Properties: CLL03413 (10086996 TEP No. Analysis By:AJ 10/21/2025 Checked By:SMS 10/21/2025 Moment Bolt Group - Face Connection 1 Code Revisions: Bolt Type: Bolt Size:0.625 in # Bolt Legs:4 Slip Capacity=9.1%PASS Plate Width:N/A in Bolt Capacity=31.7%PASS Plate Height:N/A in #VALUE! #VALUE! Bolt H Gap:5.125 in Bolt V Gap:6.00 in Plate T:N/A in Slip Member Ø:4.50 in Bolt Grade:A36 Fybolt:36.0 ksi Fubolt:58.0 ksi r:3.9 in J:62.3 in4/in2 Abolt:0.3 in2 Abolt, Net Tensile:0.2 in2 Pretension:6.1 kips Capacities: 272252.116951 ANSI/TIA-222-H U-Bolts Connection Inputs: Bolt Properties: CLL03413 (10086996) TEP No. Analysis By:AJ 10/21/2025 Checked By:SMS 10/21/2025 Moment Bolt Group - Face Connection 2 Code Revisions: Bolt Type: Bolt Size:0.625 in # Bolt Legs:4 Slip Capacity=14.1%PASS Plate Width:N/A in Bolt Capacity=34.0%PASS Plate Height:N/A in #VALUE! #VALUE! Bolt H Gap:6.00 in Bolt V Gap:4.13 in Plate T:N/A in Slip Member Ø:3.50 in Bolt Grade:A36 Fybolt:36.0 ksi Fubolt:58.0 ksi r:3.6 in J:53.0 in4/in2 Abolt:0.3 in2 Abolt, Net Tensile:0.2 in2 Pretension:6.1 kips 272252.116941 ANSI/TIA-222-H U-Bolts Connection Inputs: Bolt Properties: Capacities: October 21, 2025 T-Arm Mount Analysis Main / Dyer (CLL03413) TEP Project Number 272252.1169408 Page 6 APPENDIX C SUPPLEMENTAL DRAWINGS SitePro1.com 888-438-7761 Pxxx: Bulk Pipe Features: • Factory cut end, hot-dip galvanized pipe Construction: • ASTM A53 Grade B • Schedule 40 or Schedule 80 Design Criteria: • ASTM A53 Grade B (Yield Fy = 35 ksi [240 MPa]/ Tensile Fu = 60 ksi [415 MPa]) • Hot dip galvanized in accordance with ASTM A123 requirements Part # Length OD x Length (in) Schedule 40 P260 5’-0” 2-3/8” x 60” P263 5’-3” 2-3/8” x 63” P272 6’-0” 2-3/8” x 72” P284 7’-0” 2-3/8” x 84” P296 8’-0” 2-3/8” x 96” P2108 9’-0” 2-3/8” x 108” P2120 10’-0” 2-3/8” x 120” P2126 10’-6” 2-3/8” x 126” P2150 12’-6” 2-3/8” x 150” P2174 14’-6” 2-3/8” x 174” P2252 21’-0” 2-3/8” x 252” P3072 6’-0” 2-7/8” x 72” P3084 7’-0” 2-7/8” x 84” P3096 8’-0” 2-7/8” x 96” P30108 9’-0” 2-7/8” x 108” P30120 10'-0" 2-7/8" x 120" P30126 10’-6” 2-7/8” x 126” P30150 12’-6” 2-7/8” x 150” P30174 14’-6” 2-7/8” x 174” P30252 21’-0” 2-7/8” x 252” P360 5’-0” 3-1/2” x 60” P372 6’-0” 3-1/2” x 72” P384 7’-0” 3-1/2” x 84” P396 8’-0” 3-1/2” x 96” P3150 12’-6” 3-1/2” x 150” P3160 13’-4” 3-1/2” x 160” P3174 14’-6” 3-1/2” x 174” P3216 18’-0” 3-1/2” x 216” P3252 21’-0” 3-1/2” x 252” P472 6’-0” 4-1/2” x 72” P4126 10’-6” 4-1/2” x 126” P4252 21’-0” 4-1/2” x 252” Part # Length OD x Length (in) Schedule 80 P2252-80 21’ 2-1/2” x 252” P30126-80 10’-6” 2-7/8” x 126” P30252-80 21’ 2-7/8” x 252” P3252-80 21’ 3-1/2” x 252” P2120 10’-0”2-3/8” x 120” P30120 10'-0"2-7/8" x 120" DE S C R I P T I O N DR A W I N G U S A G E C H E C K E D B Y EN G . A P P R O V A L DR A W N B Y DW G . N O . CP D N O . CE K 1 OF 1 BM C 1 / 3 0 / 2 0 1 3 1/ 3 0 / 2 0 1 3 BB P M - U UN I V E R S A L BA C K T O B A C K PI P E M O U N T CU S T O M E R BB P M - U CL A S S S U B PA R T N O . 81 0 3 PAGE TOLERANCES O N D IMENSIONS, U NLESS O THERWISE N OTED A RE: SAWED, S HEARED A ND G AS C UT E DGES DRILLED A ND G AS C UT H OLES - N O C ONING O F H OLES LASER C UT E DGES A ND H OLES - N O C ONING O F H OLES BENDS A RE ± 1 /2 D EGREE ALL O THER M ACHINING ALL O THER A SSEMBLY TO L E R A N C E N O T E S PROPRIETARY N OTE: THE D ATA A ND T ECHNIQUES C ONTAINED I N T HIS D RAWING A RE P ROPRIETARY I NFORMATION O F V ALMONT INDUSTRIES A ND C ONSIDERED A T RADE S ECRET. A NY U SE O R D ISCLOSURE W ITHOUT T HE C ONSENT O F VALMONT I NDUSTRIES I S S TRICTLY P ROHIBITED. En g i n e e r i n g Su p p o r t T e a m : 1 - 8 8 8 - 7 5 3 - 7 4 4 6 va l m o n t Lo c a t i o n s : Ne w Y o r k , N Y At l a n t a , G A Lo s A n g e l e s , C A Pl y m o u t h , I N Sa l e m , O R Da l l a s , T X PA R T S L I S T NE T W T . UN I T W T . LE N G T H PA R T D E S C R I P T I O N PA R T N O . QT Y IT E M 0. 8 2 0. 0 3 1/ 2 " H D G U S S F L A T W A S H E R G1 2 F W 24 1 0. 2 2 0. 0 1 1/ 2 " H D G L O C K W A S H E R G1 2 L W 16 2 1. 1 5 0. 0 7 1/ 2 ' ' H D G H E A V Y 2 H H E X N U T G1 2 N U T 16 3 1. 4 1 0. 3 5 1/ 2 " x 8 " T H R E A D E D R O D ( H D G . ) G1 2 R - 8 4 4 14 . 3 8 7. 1 9 9 1 / 4 i n CR O S S O V E R P L A T E SC X 3 2 5 4. 0 7 1. 0 2 5" V - C L A M P X- 1 1 5 7 6 5 4 6 3. 2 8 0. 4 1 6 1 / 2 i n 1/ 2 ' ' x 6 - 1 / 2 " H D G H E X B O L T G R 5 F U L L T H R E A D G1 2 0 6 5 8 7 X2 X2 X2 X2 X2 X2 2- 3 / 8 " O . D . T O 4 - 1 / 2 " O . D . EX I S T I N G S T A N D O F F A R M 2- 3 / 8 " O . D . T O 4 - 1 / 2 " O . D . P I P E S (O R D E R E D S E P A R A T E L Y ) 5 7 1 2 3 TO T A L W T . # 2 5 . 3 3 5 4 1 2 3 DE S C R I P T I O N DR A W I N G U S A G E C H E C K E D B Y EN G . A P P R O V A L DR A W N B Y DW G . N O . CP D N O . BM C 1 OF 1 CE K 2 / 1 8 / 2 0 1 3 6/ 3 / 2 0 0 9 SP 2 1 9 - H 2- 7 / 8 " T O 3 - 1 / 2 " PI P E M O U N T A S S E M B L Y 45 1 8 CU S T O M E R SP 2 1 9 - H CL A S S S U B PA R T N O . 81 0 1 PAGE TOLERANCES O N D IMENSIONS, U NLESS O THERWISE N OTED A RE: SAWED, S HEARED A ND G AS C UT E DGES DRILLED A ND G AS C UT H OLES - N O C ONING O F H OLES LASER C UT E DGES A ND H OLES - N O C ONING O F H OLES BENDS A RE ± 1 /2 D EGREE ALL O THER M ACHINING ALL O THER A SSEMBLY TO L E R A N C E N O T E S PROPRIETARY N OTE: THE D ATA A ND T ECHNIQUES C ONTAINED I N T HIS D RAWING A RE P ROPRIETARY I NFORMATION O F V ALMONT INDUSTRIES A ND C ONSIDERED A T RADE S ECRET. A NY U SE O R D ISCLOSURE W ITHOUT T HE C ONSENT O F VALMONT I NDUSTRIES I S S TRICTLY P ROHIBITED. En g i n e e r i n g Su p p o r t T e a m : 1 - 8 8 8 - 7 5 3 - 7 4 4 6 va l m o n t Lo c a t i o n s : Ne w Y o r k , N Y At l a n t a , G A Lo s A n g e l e s , C A Pl y m o u t h , I N Sa l e m , O R Da l l a s , T X PA R T S L I S T NE T W T . UN I T W T . LE N G T H PA R T D E S C R I P T I O N PA R T N O . QT Y IT E M 8. 6 1 8. 6 1 8 1 / 4 i n SM A L L S U P P O R T C R O S S P L A T E X- S P 2 1 9 1 1 1. 3 1 0. 6 6 1/ 2 " X 3 - 5 / 8 " X 6 " X 3 " U - B O L T ( H D G . ) X- U B 1 3 0 6 2 2 1. 3 1 0. 6 6 1/ 2 " X 3 " X 5 " X 2 " U - B O L T ( H D G . ) X- U B 1 3 0 0 2 3 0. 2 7 0. 0 3 1/ 2 " H D G U S S F L A T W A S H E R G1 2 F W 8 4 0. 1 1 0. 0 1 1/ 2 " H D G L O C K W A S H E R G1 2 L W 8 5 0. 5 7 0. 0 7 1/ 2 ' ' H D G H E A V Y 2 H H E X N U T G1 2 N U T 8 6 EX I S T I N G 2 - 7 / 8 " O D P I P E EX I S T I N G 3 - 1 / 2 " O D P I P E 12 4 5 6 3 4 5 6 X2 X2 X2 X2 X2 X2 TO T A L W T . # 1 2 . 6 1 RE V D E S C R I P T I O N O F R E V I S I O N S C P D B Y D A T E RE V I S I O N H I S T O R Y A RE D R A W N I N I N V , U P D A T E D V I E W S & T A B L E K C 8 8- 2 1 - 2 0 1 2 Project Number: 162721 Page 1 September 12, 2025 Tower Engineering Solutions, LLC 1320 Greenway Drive, Suite 600, Irving, Texas 75038 Phone: (972) 483-0607, Fax: (972) 975-9615 Structural Analysis Report Structure Information Tower Type Existing 58 ft SUMMIT Monopole Customer Information Name SBA Communications Corp Site Number CA45376-A Site Name Mcarthur Carrier Information Name AT&T Site ID / Name LAD463 / Santa Ana App # 287866, V#1 Site Information Address: 2621 South Birch Street Santa Ana, California 92707, Orange County Latitude: 33.711744° Longitude: -117.869797° Analysis Result: Max Structural Usage: 72.6% [Pass] Max Foundation Usage: 22% [Pass] Additional Usage Caused by New Mount/Mount Modification: N/A Report Prepared By: Adam Noubani Project Number: 162721 Page 2 September 12, 2025 Introduction The purpose of this report is to summarize the analysis results on the 58 ft SUMMIT Monopole to support the proposed antennas and transmission lines in addition to those currently installed. Any modification listed under Sources of Information was assumed completed and was included in this analysis. Sources of Information Document Type Remarks Tower Drawings Summit Manufacturing, Inc., Job #A29295-425 November 12, 1996 Vertical Solutions Tower Mapping, VSI#110053 dated January 20, 2011 Foundation Drawing FDH Engineering Rebar Investigation, Project #15BXLD1500 dated September 3, 2015 FDH Velocitel Foundation Mapping, Project #15BRET1500 dated June 17, 2015 Geotechnical Report Consolidated Geoscience, Job #96-122-126-01 dated November 15, 1996 Modification Drawings N/A Mount Analysis N/A Analysis Criteria The comprehensive analysis was performed in accordance with the requirements and stipulations of the TIA-222- H. In accordance with this standard, the structure was analyzed using TESPoles, a proprietary analysis software. The program considers the structure as an elastic 3-D model with second-order effects and temperature effects incorporated in the analysis. The analysis was performed using multiple wind directions. Codes and Standards ANSI/TIA-222-H / 2021 IBC / 2022 CBC Wind Parameters Basic Wind Speed (Ultimate 3-sec. Gust), VULT: 95.0 mph Ice Wind Speed (3-sec. Gust): N/A Design Ice Thickness: No Ice Service Load Wind Speed: 60 mph + 0” Radial ice Exposure Category: B Risk Category: II Ground Elevation Factor (Ke): 0.998 Topographic Parameters Method: Method 1 Feature Type: Flat Crest Height (H): 0 ft Length of Feature (L): 0.0 ft Distance to crest (x): 0.0 ft Seismic Parameters: SS 1.279 g S1 0.458 g This structural analysis is based upon the tower being classified as a Risk Category II; however, if a different classification is required subsequent to the date hereof, the tower classification will be changed to meet such requirement and a new structural analysis will be run. Project Number: 162721 Page 3 September 12, 2025 Existing Antennas, Mounts and Transmission Lines The table below summarizes the antennas, mounts and transmission lines that were considered in the analysis as existing on the tower. Proposed Carrier’s Final Configuration of Antennas, Mounts and Transmission Lines Information pertaining to the proposed carrier’s final configuration of antennas and transmission lines was provided by SBA Communications Corp. The proposed antennas and lines are listed below. All transmission lines are considered running inside of the pole shafts. Items Elevation (ft) Qty Antenna Descriptions Mount Type & Qty. Transmission Lines Owner 1 58.0 3 Nokia TD LTE 2.5G Massive MIMO- AAHC - Panel Low Profile Platform (3) 1.25" Hybrid (1) 1.689" Hybrid Sprint Nextel 2 3 Commscope TPA65R-KE6DA-K - Panel 3 6 Alcatel Lucent RRH-2x50-800 4 6 Alcatel Lucent 1900MHz 4x45 RRH 5 3 Nokia Airscale 6 54.5 4 Dish w/ ODU - Dish Pipe (4) 1/2" - 52.0 3 Ericsson-RRUS 4478 B14-RRU (1) Monopole Triple T- ARM (Valmont RMV12_4XX) & (1) Platform Reinforcement (Valmont PRK- 1245L) (2) 3/16" RET (7) 3/4" DC (4) 3/8" Fiber (18) 7/8" (1) 5/16" RET AT&T - 3 Ericsson-RRUS 32 B30-RRU - 3 Ericsson-8843 B25/B66A-RRU - 1 Raycap-DC6-48-60-18-8F-OVP - 1 Raycap-DC9-48-60-24-8C-EV-OVP - 3 Cci TPA-65R-BU6DA-K-Panel - 3 Ericsson-AIR6449 N77D - Panel - 3 Kathrein-800-10965K - Panel - 3 Commscope-JAHH-65B-R3B - Panel - 3 Ericsson-RRUS-E2-RRU - 3 Ericsson-RRUS-4449 B5/B12-RRU Items Elevation (ft) Qty Antenna Descriptions Mount Type & Qty. Transmission Lines Owner 7 53.6 3 Ericsson AIR6472 B77G B77M – Panel (1) Monopole Triple T- ARM (Valmont RMV12_4XX) & (1) Platform Reinforcement (Valmont PRK- 1245L) (18) 7/8" (1) 5/16" RET (2) 3/16" RET (7) 3/4" DC (4) 3/8" Fiber AT&T 8 52.0 3 Kathrein 800-10965K – Panel 9 3 Commscope JAHH-65B-R3B – Panel 10 3 Cci TPA-65R-BU6DA-K – Panel 11 3 Ericsson RRUS-4449 B5/B12 – RRU 12 3 Ericsson RRUS 4478 B14 – RRU 13 3 Ericsson RRUS-E2 – RRU 14 3 Ericsson RRUS 32 B30 – RRU 15 3 Ericsson RRUS 8843 B2 B66A – RRU 16 3 Raycap DC6-48-60-18-8F – OVP 17 1 Raycap DC9-48-60-24-8C-EV – OVP Project Number: 162721 Page 4 September 12, 2025 Analysis Results The results of the structural analysis, performed for the wind and ice loading and antenna equipment as defined above, are summarized as the following: Tower Component Utilization % Pass / Fail Pole Shaft 72.6% Pass Anchor Bolt 48.7% Pass Base Plate 29.6% Pass Serviceability 34.2% Pass Structure Rating – (Controlling Utilization of all Components) 72.6% Foundations Moment (Kip-Ft) Shear (Kips) Axial (Kips) Analysis Reactions 366.5 7.4 14.1 The foundation has been investigated using the supplied documents and soils report and was found adequate. Therefore, no modification to the foundation will be required. Service Load Condition (Rigidity) The maximum twist and sway of the microwave dishes under the operational wind speed as specified in the Analysis Criteria are listed in the table below: Elevation (ft) Antenna / Dish Carrier Twist (deg) Sway (deg) 54.5 Dish w/ ODU - Dish Sprint Nextel 0.000 0.976 It is recommended that the carriers review the twist and sway values of the microwave dishes. Conclusions Based on the analysis results, the existing structure and its foundation were found to be adequate to safely support the existing and proposed equipment and meet the minimum requirements per the TIA-222 Standard under the design basic wind speed as specified in the Analysis Criteria. Project Number: 162721 Page 5 September 12, 2025 Standard Conditions 1. This analysis was performed based on the information supplied to (TES) Tower Engineering Solutions, LLC. Verification of the information provided was not included in the Scope of Work for TES. The accuracy of the analysis is dependent on the accuracy of the information provided. 2. The structural analysis was performance based upon the evidence available at the time of this report. All information provided by the client is considered to be accurate. 3. The analyses will be performed based on the codes as specified by the client or based on the best knowledge of the engineering staff of TES. In the absence of information to the contrary, all work will be performed in accordance with the latest relevant revision of ANSI/TIA-222. If wind speed and/or ice loads are different from the minimum values recommended by the ANSI/TIA-222 standard or other codes, TES should be notified in writing and the applicable minimum values provided by the client. 4. The configuration of the existing mounts, antennas, coax and other appurtenances were supplied by the customer for the current structural analysis. TES has not visited the tower site to verify the adequacy of the information provided. If there is any discrepancy found in the report regarding the existing conditions, TES should be notified immediately to evaluate the effect of the discrepancy on the analysis results. 5. The client will assume responsibility for rework associated with the differences in initially provided information, including tower and foundation information, existing and/or proposed equipment and transmission lines. 6. If a feasibility analysis was performed, final acceptance of changed conditions shall be based upon a comprehensive structural analysis. Structure:CA45376-A-SBA Site Name:Mcarthur Height:58.00 (ft) 9/12/2025 Page: 1 Code:EIA/TIA-222-H Exposure:B Gh:1.1 Base Elev:0.000 (ft) Usage Diagram - Max Ratio 72.61% at 0.0ft Load Case : 1.2D + 1.0W 95 mph Wind at 60° Dead Load Factor: Wind Load Factor: 1.20 1.00 20Iterations: Copyright 2025 by Tower Engineering Solutions, LLC. All rights reserved. Wind Speed: Ice Thickness:0.00 95.00 Type:Tapered Site Name:Mcarthur Height:58.00 (ft) 9/12/2025 Page: 2 Base Shape:12 Sided Taper:0.24009 Base Elev:0.00 (ft) Structure: CA45376-A-SBA Wind Speed: Ice Thickness:0.00 95.00 Shaft Properties Seq Length (ft) Top (in) Bottom (in) Thick (in) Joint Type Taper Grade (ksi) 1 30.00 0.188 0.2400920.85 6028.05 2 31.00 0.188 0.24009Slip14.50 6021.94 Discrete Appurtenances Attach Elev (ft) Force Elev (ft)Qty Description Carrier 58.00 3 Nokia TD LTE 2.5G Massive MIMO-AAHC 58.00 Sprint Nextel 58.00 3 Commscope TPA65R-KE6DA-K 58.00 Sprint Nextel 58.00 6 Alcatel Lucent RRH-2x50-800 58.00 Sprint Nextel 58.00 6 Alcatel Lucent 1900MHz 4x45 RRH 58.00 Sprint Nextel 58.00 3 Nokia Airscale58.00 Sprint Nextel 58.00 1 Low Profile Platform58.00 Sprint Nextel 54.50 3 Standoff Mount54.50 Sprint Nextel 54.50 4 Dish w/ ODU54.50 Sprint Nextel 52.00 3 Ericsson AIR6472 B77G B77M 53.60 AT&T 52.00 3 TPA-65R-BU6DA-K52.00 AT&T 52.00 3 800-10965K52.00 AT&T 52.00 3 JAHH-65B-R3B52.00 AT&T 52.00 1 RMV12_4XX52.00 AT&T 52.00 1 PRK-1245L52.00 AT&T 52.00 3 RRUS-E252.00 AT&T 52.00 3 RRUS-4449 B5/B1252.00 AT&T 52.00 3 RRUS 4478 B1452.00 AT&T 52.00 3 RRUS 32 B3052.00 AT&T 52.00 3 8843 B25/B66A52.00 AT&T 52.00 1 DC6-48-60-18-8F52.00 AT&T 52.00 1 DC9-48-60-24-8C-EV52.00 AT&T 46.50 1 Shroud46.50 Linear Appurtenances Elev From (ft) Elev To (ft)Placement Description Carrier 0.00 58.00 Inside 1.25" Hybrid Sprint Nextel 0.00 58.00 Inside 1.689" Hybrid Sprint Nextel 0.00 54.50 Inside 1/2" Coax Sprint Nextel 0.00 54.00 Inside 5/16" RET AT&T 0.00 52.00 Inside 3/16" RET AT&T 0.00 52.00 Inside 3/4" DC AT&T 0.00 52.00 Inside 3/8" Fiber AT&T 0.00 52.00 Inside 7/8" Coax AT&T Anchor Bolts Qty Specifications Arrangement Grade (ksi) 4 2.25" 18J 75.0 Cluster Base Plate Thickness (in) Specifications (in) Grade (ksi)Geometry 2.5000 31.0 50.0 Square Reactions Load Case Moment (FT-Kips) Shear (Kips) Axial (Kips) Copyright 2025 by Tower Engineering Solutions, LLC. All rights reserved. Type:Tapered Site Name:Mcarthur Height:58.00 (ft) 9/12/2025 Page: 3 Base Shape:12 Sided Taper:0.24009 Base Elev:0.00 (ft) Structure: CA45376-A-SBA Wind Speed: Ice Thickness:0.00 95.00 1.2D + 1.0W 95 mph Wind 366.5 7.4 14.1 1.2D + 1.0W 95 mph Wind at 30°317.4 6.4 14.1 1.2D + 1.0W 95 mph Wind at 60°183.2 3.7 14.1 1.2D + 1.0W 95 mph Wind at 90°0.0 0.0 14.1 1.2D + 1.0W 95 mph Wind at 120°183.2 3.7 14.1 1.2D + 1.0W 95 mph Wind at 150°317.4 6.4 14.1 1.2D + 1.0W 95 mph Wind at 180°366.5 7.4 14.1 1.2D + 1.0W 95 mph Wind at 210°317.4 6.4 14.1 1.2D + 1.0W 95 mph Wind at 240°183.2 3.7 14.1 1.2D + 1.0W 95 mph Wind at 270°0.0 0.0 14.1 1.2D + 1.0W 95 mph Wind at 300°183.2 3.7 14.1 1.2D + 1.0W 95 mph Wind at 330°317.4 6.4 14.1 0.9D + 1.0W 95 mph Wind 362.1 7.4 10.6 0.9D + 1.0W 95 mph Wind at 30°313.6 6.4 10.6 0.9D + 1.0W 95 mph Wind at 60°181.0 3.7 10.6 0.9D + 1.0W 95 mph Wind at 90°0.0 0.0 10.6 0.9D + 1.0W 95 mph Wind at 120°181.0 3.7 10.6 0.9D + 1.0W 95 mph Wind at 150°313.6 6.4 10.6 0.9D + 1.0W 95 mph Wind at 180°362.1 7.4 10.6 0.9D + 1.0W 95 mph Wind at 210°313.6 6.4 10.6 0.9D + 1.0W 95 mph Wind at 240°181.0 3.7 10.6 0.9D + 1.0W 95 mph Wind at 270°0.0 0.0 10.6 0.9D + 1.0W 95 mph Wind at 300°181.0 3.7 10.6 0.9D + 1.0W 95 mph Wind at 330°313.6 6.4 10.6 1.0D + 1.0W 60 mph Wind 129.9 2.6 11.8 1.0D + 1.0W 60 mph Wind at 30°112.5 2.3 11.8 1.0D + 1.0W 60 mph Wind at 60°64.9 1.3 11.8 1.0D + 1.0W 60 mph Wind at 90°0.0 0.0 11.8 1.0D + 1.0W 60 mph Wind at 120°64.9 1.3 11.8 1.0D + 1.0W 60 mph Wind at 150°112.5 2.3 11.8 1.0D + 1.0W 60 mph Wind at 180°129.9 2.6 11.8 1.0D + 1.0W 60 mph Wind at 210°112.5 2.3 11.8 1.0D + 1.0W 60 mph Wind at 240°64.9 1.3 11.8 1.0D + 1.0W 60 mph Wind at 270°0.0 0.0 11.8 1.0D + 1.0W 60 mph Wind at 300°64.9 1.3 11.8 1.0D + 1.0W 60 mph Wind at 330°112.5 2.3 11.8 1.2D + 1.0Ev + 1.0Eh 180.6 3.2 16.1 0.9D + 1.0Ev + 1.0Eh 178.4 3.2 12.6 Copyright 2025 by Tower Engineering Solutions, LLC. All rights reserved. Type:Monopole Site Name:Mcarthur Height:58.00 (ft) 9/12/2025 Page: 4 Structure: CA45376-A-SBA - Coax Line Placement Copyright 2025 by Tower Engineering Solutions, LLC. All rights reserved. Shaft Properties Structure:CA45376-A-SBA Site Name:Mcarthur Height:58.00 (ft) 9/12/2025 Page: 5 Code:TIA-222-H Exposure:B Gh:1.1 Base Elev:0.000 (ft) Crest Height:0.00 Site Class: IIStruct Class: D - Stiff Soil Topography:1 Sec. No. Length (ft) Thick (in) Fy (ksi) Joint Type Overlap (in) Weight (lb)Shape 30.000 0.1875 60 0.00 1,495112 31.000 0.1875 60 Slip 36.00 1,149212 2,644Total Shaft Weight: Dia (in) Elev (ft) Area (sqin) Ix (in^4) W/t Ratio D/t Ratio Dia (in) Elev (ft) Area (sqin) Ix (in^4) W/t Ratio D/t Ratio Taper TopBottom Sec. No. 28.05 0.00 16.82 1666.88 37.94 149.60 20.85 30.00 12.47 679.56 27.65 111.1 9 0.2400861 21.94 27.00 13.13 793.47 29.21 117.03 14.50 58.00 8.64 225.94 18.58 77.33 0.2400862 Copyright 2025 by Tower Engineering Solutions, LLC. All rights reserved. Load Summary Structure:CA45376-A-SBA Site Name:Mcarthur Height:58.00 (ft) 9/12/2025 Page: 6 Code:EIA_H Exposure:B Gh:1.1 Base Elev:0.000 (ft) Crest Height:0.00 Site Class: IIStruct Class: D - Stiff Soil Topography:1 Discrete Appurtenances IceNo Ice Description Qty Weight (lb) CaAa (sf) CaAa Factor Weight (lb) CaAa (sf) CaAa Factor Hor. Ecc. (ft) Vert Ecc (ft)No. Elev (ft) Nokia TD LTE 2.5G Massive MIMO-AAHC 3 103.60 4.20 0.75 0.0058.00 0.000 0.75 0.00 0.00 1 Commscope TPA65R-KE6DA-K 3 67.50 12.87 0.72 0.0058.00 0.000 0.72 0.00 0.00 2 Alcatel Lucent RRH-2x50-800 6 69.10 2.40 0.67 0.0058.00 0.000 0.67 0.00 0.00 3 Alcatel Lucent 1900MHz 4x45 RRH 6 60.00 2.71 0.67 0.0058.00 0.000 0.67 0.00 0.00 4 Nokia Airscale 3 50.70 3.68 0.67 0.0058.00 0.000 0.67 0.00 0.00 5 Low Profile Platform 1 1500.00 22.00 1.00 1800.0058.00 27.000 1.00 0.00 0.00 6 Standoff Mount 3 87.00 4.31 1.00 118.0054.50 5.840 1.00 0.00 0.00 7 Dish w/ ODU 4 45.00 4.69 1.00 55.0054.50 5.050 1.00 0.00 0.00 8 Ericsson AIR6472 B77G B77M 3 77.16 4.78 0.76 0.0052.00 0.000 0.76 0.00 1.60 9 TPA-65R-BU6DA-K 3 67.50 12.87 0.72 0.0052.00 0.000 0.74 0.00 0.0010 800-10965K 3 108.60 13.81 0.71 0.0052.00 0.000 0.73 0.00 0.0011 JAHH-65B-R3B 3 63.30 9.11 0.83 0.0052.00 0.000 0.86 0.00 0.0012 RMV12_4XX 1 1357.77 29.95 1.00 1600.0052.00 34.000 1.00 0.00 0.0013 PRK-1245L 1 464.91 9.50 1.00 560.0052.00 11.000 1.00 0.00 0.0014 RRUS-E2 3 59.40 3.15 0.75 0.0052.00 0.000 0.67 0.00 0.0015 RRUS-4449 B5/B12 3 71.00 1.97 0.67 0.0052.00 0.000 0.67 0.00 0.0016 RRUS 4478 B14 3 59.40 1.65 0.67 0.0052.00 0.000 0.67 0.00 0.0017 RRUS 32 B30 3 60.00 2.74 0.67 0.0052.00 0.000 0.67 0.00 0.0018 8843 B25/B66A 3 72.00 1.64 0.67 0.0052.00 0.000 0.67 0.00 0.0019 DC6-48-60-18-8F 1 31.80 0.92 0.67 0.0052.00 0.000 0.67 0.00 0.0020 DC9-48-60-24-8C-EV 1 26.20 1.14 0.67 0.0052.00 0.000 0.67 0.00 0.0021 Shroud 1 1000.00 35.95 1.00 0.0046.50 0.000 1.00 0.00 0.0022 61Totals:8,176.76 4,534.00 Linear Appurtenances Exposed Width Exposed Bottom Elev. (ft)Description Top Elev. (ft) 0.00 58.00 (3) 1.25" Hybrid 0.00 Inside 0.00 58.00 (1) 1.689" Hybrid 0.00 Inside 0.00 54.50 (4) 1/2" Coax 0.00 Inside 0.00 54.00 (1) 5/16" RET 0.00 Inside 0.00 52.00 (2) 3/16" RET 0.00 Inside 0.00 52.00 (7) 3/4" DC 0.00 Inside 0.00 52.00 (4) 3/8" Fiber 0.00 Inside 0.00 52.00 (18) 7/8" Coax 0.00 Inside Copyright 2025 by Tower Engineering Solutions, LLC. All rights reserved. Shaft Section Properties Structure:CA45376-A-SBA Site Name:Mcarthur Height:58.00 (ft) 9/12/2025 Page: 7 Code:TIA-222-H Exposure:B Gh:1.1 Base Elev:0.000 (ft) Crest Height:0.00 Site Class: IIStruct Class: D - Stiff Soil Topography:1 Increment Length: 5 (ft) Elev (ft)Description Thick (in) Dia (in) Area (in^2) Ix (in^4) W/t Ratio D/t Ratio Fpy (ksi) S (in^3) Weight (lb) 0.1875 28.050 16.822 1666.9 37.940.00 149.60 60.0 114.8 0.0 0.1875 26.850 16.097 1460.6 36.235.00 143.20 61.6 105.1 280.0 0.1875 25.649 15.372 1272.0 34.5110.00 136.80 63.3 95.8 267.7 0.1875 24.449 14.648 1100.5 32.8015.00 130.39 64.9 87.0 255.4 0.1875 23.248 13.923 945.1 31.0820.00 123.99 66.6 78.5 243.0 0.1875 22.048 13.198 805.0 29.3625.00 117.59 68.3 70.5 230.7 Bot - Section 2 0.1875 21.568 12.908 753.1 28.6827.00 115.03 68.9 67.5 88.8 Top - Section 1 0.1875 21.222 12.700 717.2 28.1830.00 113.19 0.0 0.0 261.4 0.1875 20.022 11.975 601.3 26.4735.00 106.78 71.1 58.0 209.9 0.1875 18.822 11.250 498.6 24.7540.00 100.38 72.7 51.2 197.6 0.1875 17.621 10.526 408.3 23.0445.00 93.98 74.4 44.8 185.2 0.1875 17.261 10.308 383.5 22.5246.50 92.06 74.9 42.9 53.2 0.1875 16.421 9.801 329.7 21.3250.00 87.58 75.6 38.8 119.7 0.1875 15.941 9.511 301.3 20.6452.00 85.02 75.6 36.5 65.7 0.1875 15.340 9.149 268.1 19.7854.50 81.81 75.6 33.8 79.4 0.1875 15.220 9.076 261.8 19.6155.00 81.17 75.6 33.2 15.5 0.1875 14.500 8.641 225.9 18.5858.00 77.33 75.6 30.1 90.4 2643.8 Copyright 2025 by Tower Engineering Solutions, LLC. All rights reserved. Structure:CA45376-A-SBA Site Name:Mcarthur Height:58.00 (ft) 9/12/2025Code:TIA-222-H Exposure:B Base Elev:0.000 (ft) Wind Loading - Shaft Page: 8IIStruct Class:Topography:1Gh:1.1 Crest Height:0.00 Site Class:D - Stiff Soil Dead Load Factor Wind Load Factor 1.20 1.00 20IterationsLoad Case:1.2D + 1.0W 95 mph Wind at 60° - Controlling Direction Ice Thickness:0.00 Elev (ft)Description Kzt Kz qz (psf) qzGh (psf) C (mph-ft)Cf Ice Thick (in) Tributary (ft) Aa (sf) CfAa (sf) Wind Force X (lb) Dead Load Ice (lb) Tot Dead Load (lb) 1.00 0.70 15.338 16.87 192.180.00 0.000 0.00 0.000 0.00 0.0 0.0 0.00.950 1.00 0.70 15.338 16.87 183.965.00 0.000 5.00 11.841 11.25 189.8 0.0 336.10.950 1.00 0.70 15.338 16.87 175.7310.00 0.000 5.00 11.323 10.76 181.5 0.0 321.30.950 1.00 0.70 15.338 16.87 167.5115.00 0.000 5.00 10.805 10.26 173.2 0.0 306.50.950 1.00 0.70 15.338 16.87 159.2820.00 0.000 5.00 10.287 9.77 164.9 0.0 291.70.950 1.00 0.70 15.338 16.87 151.0625.00 0.000 5.00 9.770 9.28 156.6 0.0 276.90.950 Bot - Section 2 1.00 0.70 15.338 16.87 147.7727.00 0.000 2.00 3.763 3.57 60.3 0.0 106.60.950 Top - Section 1 1.00 0.70 15.351 16.89 142.8930.00 0.000 3.00 5.586 5.31 89.6 0.0 313.70.950 1.00 0.73 16.042 17.65 140.2935.00 0.000 5.00 8.896 8.45 149.1 0.0 251.90.950 1.00 0.76 16.666 18.33 134.4240.00 0.000 5.00 8.378 7.96 145.9 0.0 237.10.950 1.00 0.79 17.237 18.96 127.9845.00 0.000 5.00 7.860 7.47 141.6 0.0 222.30.950 Appurtenance(s)1.00 0.79 17.399 19.14 125.9646.50 0.000 1.50 2.257 2.14 41.0 0.0 63.80.950 1.00 0.81 17.763 19.54 121.0750.00 0.000 3.50 5.085 4.83 94.4 0.0 143.70.950 Appurtenance(s)1.00 0.82 17.963 19.76 118.1952.00 0.000 2.00 2.792 2.65 52.4 0.0 78.90.950 Appurtenance(s)1.00 0.83 18.206 20.03 114.5154.50 0.000 2.50 3.373 3.20 64.2 0.0 95.20.950 1.00 0.83 18.254 20.08 113.7655.00 0.000 0.50 0.659 0.63 12.6 0.0 18.60.950 Appurtenance(s)1.00 0.85 18.533 20.39 109.2058.00 0.000 3.00 3.846 3.65 74.5 0.0 108.50.950 58.00Totals:1,791.6 3,172.6 Copyright 2025 by Tower Engineering Solutions, LLC. All rights reserved. Structure:CA45376-A-SBA Site Name:Mcarthur Height:58.00 (ft) 9/12/2025Code:TIA-222-H Exposure:B Base Elev:0.000 (ft) Page: 9IIStruct Class:Topography:1Gh:1.1 Crest Height:0.00 Site Class:D - Stiff Soil Discrete Appurtenance Forces Dead Load Factor Wind Load Factor 1.20 1.00 20IterationsLoad Case:1.2D + 1.0W 95 mph Wind at 60° - Controlling Direction Elev (ft)Description Qty qz (psf) qzGh (psf) Orient Factor x Ka Total CaAa (sf) Horiz Ecc (ft) Vert Ecc (ft) Wind FX (lb) Mom Y (lb-ft) Mom Z (lb-ft) Dead Load (lb)No.Ka Alcatel Lucent RRH-2x50-800 6 18.533 20.386 0.6058.00 8.68 0.000 0.000 -88.51 0.00 0.00497.52 1 0.90 Nokia TD LTE 2.5G Massive MIMO-AAHC 3 18.533 20.386 0.6858.00 8.51 0.000 0.000 -86.69 0.00 0.00372.96 2 0.90 Commscope TPA65R-KE6DA-K 3 18.533 20.386 0.6558.00 25.02 0.000 0.000 -255.02 0.00 0.00243.00 3 0.90 Low Profile Platform 1 18.533 20.386 1.0058.00 22.00 0.000 0.000 -224.25 0.00 0.001800.00 4 1.00 Alcatel Lucent 1900MHz 4x45 RRH 6 18.533 20.386 0.6058.00 9.80 0.000 0.000 -99.94 0.00 0.00432.00 5 0.90 Nokia Airscale 3 18.533 20.386 0.6058.00 6.66 0.000 0.000 -67.86 0.00 0.00182.52 6 0.90 Dish w/ ODU 4 18.206 20.027 1.0054.50 18.76 0.000 0.000 -187.85 0.00 0.00216.00 7 1.00 Standoff Mount 3 18.206 20.027 1.0054.50 12.93 0.000 0.000 -129.47 0.00 0.00313.20 8 1.00 DC9-48-60-24-8C-EV 1 17.963 19.760 0.5452.00 0.61 0.000 0.000 -6.04 0.00 0.0031.44 9 0.80 DC6-48-60-18-8F 1 17.963 19.760 0.5452.00 0.49 0.000 0.000 -4.87 0.00 0.0038.16100.80 8843 B25/B66A 3 17.963 19.760 0.5452.00 2.64 0.000 0.000 -26.05 0.00 0.00259.20110.80 RRUS 32 B30 3 17.963 19.760 0.5452.00 4.41 0.000 0.000 -43.53 0.00 0.00216.00120.80 RRUS 4478 B14 3 17.963 19.760 0.5452.00 2.65 0.000 0.000 -26.21 0.00 0.00213.84130.80 RRUS-4449 B5/B12 3 17.963 19.760 0.5452.00 3.17 0.000 0.000 -31.30 0.00 0.00255.60140.80 RRUS-E2 3 17.963 19.760 0.6052.00 5.67 0.000 0.000 -56.02 0.00 0.00213.84150.80 PRK-1245L 1 17.963 19.760 1.0052.00 9.50 0.000 0.000 -93.86 0.00 0.00557.89161.00 RMV12_4XX 1 17.963 19.760 1.0052.00 29.95 0.000 0.000 -295.90 0.00 0.001629.32171.00 JAHH-65B-R3B 3 17.963 19.760 0.6652.00 18.15 0.000 0.000 -179.29 0.00 0.00227.88180.80 800-10965K 3 17.963 19.760 0.5752.00 23.53 0.000 0.000 -232.50 0.00 0.00390.96190.80 TPA-65R-BU6DA-K 3 17.963 19.760 0.5852.00 22.24 0.000 0.000 -219.72 0.00 0.00243.00200.80 Ericsson AIR6472 B77G B77M 3 18.120 19.932 0.6152.00 8.72 0.000 1.600 -86.89 0.00 -139.02277.78210.80 Shroud 1 17.399 19.139 1.0046.50 35.95 0.000 0.000 -344.02 0.00 0.001200.00221.00 -2,785.79Totals:9,812.11 Copyright 2025 by Tower Engineering Solutions, LLC. All rights reserved. Structure:CA45376-A-SBA Site Name:Mcarthur Height:58.00 (ft) 9/12/2025Code:TIA-222-H Exposure:B Base Elev:0.000 (ft) Total Applied Force Summary Page: 10IIStruct Class:Topography:1Gh:1.1 Crest Height:0.00 Site Class:D - Stiff Soil Dead Load Factor Wind Load Factor 1.20 1.00 20IterationsLoad Case:1.2D + 1.0W 95 mph Wind at 60° - Controlling Direction Elev (ft) Lateral FX (-) (lb) Axial FY (-) (lb) Torsion MY (lb-ft) Moment MZ (lb-ft)Description 0.00 0.00 0.000.00 0.00 -94.89 -440.93 0.005.00 0.00 -90.74 -426.13 0.0010.00 0.00 -86.59 -411.34 0.0015.00 0.00 -82.44 -396.54 0.0020.00 0.00 -78.29 -381.74 0.0025.00 0.00 -30.16 -148.55 0.0027.00 0.00 -44.80 -376.63 0.0030.00 0.00 -74.56 -356.77 0.0035.00 0.00 -72.95 -341.97 0.0040.00 0.00 -70.79 -327.18 0.0045.00 0.00 -364.54 -1295.27 0.0046.50 0.00(1) attachments -47.20 -217.11 0.0050.00 0.00 -1328.39 -4675.72 0.0052.00 -139.02(31) attachments -349.41 -639.45 0.0054.50 0.00(7) attachments -6.29 -21.18 0.0055.00 0.00 -859.51 -3652.00 0.0058.00 0.00(22) attachments -3,681.57Totals:-14,108.5 1 0.00 -139.02 Copyright 2025 by Tower Engineering Solutions, LLC. All rights reserved. Structure:CA45376-A-SBA Site Name:Mcarthur Height:58.00 (ft) 9/12/2025Code:TIA-222-H Exposure:B Base Elev:0.000 (ft) Calculated Forces Page: 11IIStruct Class:Topography:1Gh:1.1 Crest Height:0.00 Site Class:D - Stiff Soil Dead Load Factor Wind Load Factor 1.20 1.00 20Load Case: 1.2D + 1.0W 95 mph Wind at 60° -Controlling Direction Iterations Seg Elev (ft) Pu FY (-) (kips) Vu FX (-) (kips) Mu MZ (ft-kips) Mu MX (ft-kips) Resultant Moment (ft-kips) phi Pn (kips) Total Deflect (in) Rotation Sway (deg) Stress Ratio Tu MY (-) (ft-kips) phi Vn (kips) phi Tn (ft-kips) phi Mn (ft-kips) Rotation Twist (deg) -14.09 -3.70 0.00 -317.38 366.470.00 907.79 0.00 0.000 0.726-183.24 272.52 632.75 516.26 0.000 -13.61 -3.64 0.00 -285.33 329.475.00 892.72 0.16 0.297 0.694-164.74 260.78 579.40 485.67 0.000 -13.15 -3.58 0.00 -253.80 293.0710.00 875.48 0.63 0.600 0.660-146.54 249.03 528.40 454.70 0.000 -12.70 -3.53 0.00 -222.76 257.2415.00 856.08 1.43 0.908 0.623-128.64 237.29 479.75 423.51 0.000 -12.27 -3.48 0.00 -192.20 221.9520.00 834.51 2.55 1.218 0.581-111.00 225.55 433.45 392.25 0.000 -11.87 -3.42 0.00 -162.10 187.2025.00 810.78 3.99 1.525 0.534-93.63 213.81 389.50 361.10 0.000 -11.70 -3.40 0.00 -150.27 173.5427.00 800.68 4.66 1.653 0.513-86.80 209.11 372.57 348.71 0.000 -11.30 -3.37 0.00 -132.61 153.1530.00 793.21 5.76 1.838 0.466-76.61 205.74 360.64 339.82 0.000 -10.92 -3.32 0.00 -103.41 119.4435.00 765.83 7.84 2.123 0.402-59.75 194.00 320.65 309.20 0.000 -10.56 -3.26 0.00 -74.70 86.2740.00 736.28 10.20 2.367 0.325-43.17 182.26 283.01 279.11 0.000 -10.22 -3.19 0.00 -46.50 53.7045.00 704.56 12.79 2.566 0.231-26.87 170.51 247.72 249.71 0.000 -8.95 -2.80 0.00 -38.21 44.1346.50 694.63 13.61 2.617 0.197-22.08 166.99 237.59 241.05 0.000 -8.74 -2.76 0.00 -21.23 24.5250.00 666.85 15.56 2.707 0.126-12.27 158.77 214.78 219.90 0.000 -4.19 -1.32 0.00 -11.45 13.2252.00 647.12 16.70 2.739 0.071-6.62 154.08 202.26 207.01 0.000 -3.59 -0.95 0.00 -5.74 6.6354.50 622.46 18.15 2.763 0.041-3.32 148.21 187.14 191.45 0.000 -3.56 -0.95 0.00 -4.92 5.6855.00 617.53 18.44 2.766 0.036-2.84 147.03 184.19 188.41 0.000 0.00 -0.86 0.00 0.00 0.0058.00 587.95 20.18 2.775 0.0000.00 139.99 166.96 170.68 0.000 Copyright 2025 by Tower Engineering Solutions, LLC. All rights reserved. Structure:CA45376-A-SBA Site Name:Mcarthur Height:58.00 (ft) 9/12/2025Code:TIA-222-H Exposure:B Base Elev:0.000 (ft) Wind Loading - Shaft Page: 12IIStruct Class:Topography:1Gh:1.1 Crest Height:0.00 Site Class:D - Stiff Soil Dead Load Factor Wind Load Factor 1.00 1.00 18IterationsLoad Case:1.0D + 1.0W 60 mph Wind - Controlling Direction Ice Thickness:0.00 Elev (ft)Description Kzt Kz qz (psf) qzGh (psf) C (mph-ft)Cf Ice Thick (in) Tributary (ft) Aa (sf) CfAa (sf) Wind Force X (lb) Dead Load Ice (lb) Tot Dead Load (lb) 1.00 0.70 5.474 6.02 121.380.00 0.000 0.00 0.000 0.00 0.0 0.0 0.00.950 1.00 0.70 5.474 6.02 116.185.00 0.000 5.00 11.841 11.25 67.7 0.0 280.00.950 1.00 0.70 5.474 6.02 110.9910.00 0.000 5.00 11.323 10.76 64.8 0.0 267.70.950 1.00 0.70 5.474 6.02 105.7915.00 0.000 5.00 10.805 10.26 61.8 0.0 255.40.950 1.00 0.70 5.474 6.02 100.6020.00 0.000 5.00 10.287 9.77 58.8 0.0 243.00.950 1.00 0.70 5.474 6.02 95.4125.00 0.000 5.00 9.770 9.28 55.9 0.0 230.70.950 Bot - Section 2 1.00 0.70 5.474 6.02 93.3327.00 0.000 2.00 3.763 3.57 21.5 0.0 88.80.950 Top - Section 1 1.00 0.70 5.479 6.03 90.2530.00 0.000 3.00 5.586 5.31 32.0 0.0 261.40.950 1.00 0.73 5.726 6.30 88.6135.00 0.000 5.00 8.896 8.45 53.2 0.0 209.90.950 1.00 0.76 5.948 6.54 84.9040.00 0.000 5.00 8.378 7.96 52.1 0.0 197.60.950 1.00 0.79 6.152 6.77 80.8345.00 0.000 5.00 7.860 7.47 50.5 0.0 185.20.950 Appurtenance(s)1.00 0.79 6.210 6.83 79.5546.50 0.000 1.50 2.257 2.14 14.6 0.0 53.20.950 1.00 0.81 6.340 6.97 76.4750.00 0.000 3.50 5.085 4.86 33.9 0.0 119.70.955 Appurtenance(s)1.00 0.82 6.411 7.05 74.6552.00 0.000 2.00 2.792 2.69 19.0 0.0 65.70.963 Appurtenance(s)1.00 0.83 6.498 7.15 72.3254.50 0.000 2.50 3.373 3.28 23.5 0.0 79.40.973 1.00 0.83 6.515 7.17 71.8555.00 0.000 0.50 0.659 0.64 4.6 0.0 15.50.976 Appurtenance(s)1.00 0.85 6.614 7.28 68.9758.00 0.000 3.00 3.846 3.80 27.7 0.0 90.40.989 58.00Totals:641.6 2,643.8 Copyright 2025 by Tower Engineering Solutions, LLC. All rights reserved. Structure:CA45376-A-SBA Site Name:Mcarthur Height:58.00 (ft) 9/12/2025Code:TIA-222-H Exposure:B Base Elev:0.000 (ft) Page: 13IIStruct Class:Topography:1Gh:1.1 Crest Height:0.00 Site Class:D - Stiff Soil Discrete Appurtenance Forces Dead Load Factor Wind Load Factor 1.00 1.00 18IterationsLoad Case:1.0D + 1.0W 60 mph Wind - Controlling Direction Elev (ft)Description Qty qz (psf) qzGh (psf) Orient Factor x Ka Total CaAa (sf) Horiz Ecc (ft) Vert Ecc (ft) Wind FX (lb) Mom Y (lb-ft) Mom Z (lb-ft) Dead Load (lb)No.Ka Alcatel Lucent RRH-2x50-800 6 6.614 7.276 0.6058.00 8.68 0.000 0.000 -63.18 0.00 0.00414.60 1 0.90 Nokia TD LTE 2.5G Massive MIMO-AAHC 3 6.614 7.276 0.6858.00 8.51 0.000 0.000 -61.88 0.00 0.00310.80 2 0.90 Commscope TPA65R-KE6DA-K 3 6.614 7.276 0.6558.00 25.02 0.000 0.000 -182.04 0.00 0.00202.50 3 0.90 Low Profile Platform 1 6.614 7.276 1.0058.00 22.00 0.000 0.000 -160.07 0.00 0.001500.00 4 1.00 Alcatel Lucent 1900MHz 4x45 RRH 6 6.614 7.276 0.6058.00 9.80 0.000 0.000 -71.34 0.00 0.00360.00 5 0.90 Nokia Airscale 3 6.614 7.276 0.6058.00 6.66 0.000 0.000 -48.44 0.00 0.00152.10 6 0.90 Dish w/ ODU 4 6.498 7.148 1.0054.50 18.76 0.000 0.000 -134.09 0.00 0.00180.00 7 1.00 Standoff Mount 3 6.498 7.148 1.0054.50 12.93 0.000 0.000 -92.42 0.00 0.00261.00 8 1.00 DC9-48-60-24-8C-EV 1 6.411 7.052 0.5452.00 0.61 0.000 0.000 -4.31 0.00 0.0026.20 9 0.80 DC6-48-60-18-8F 1 6.411 7.052 0.5452.00 0.49 0.000 0.000 -3.48 0.00 0.0031.80100.80 8843 B25/B66A 3 6.411 7.052 0.5452.00 2.64 0.000 0.000 -18.60 0.00 0.00216.00110.80 RRUS 32 B30 3 6.411 7.052 0.5452.00 4.41 0.000 0.000 -31.07 0.00 0.00180.00120.80 RRUS 4478 B14 3 6.411 7.052 0.5452.00 2.65 0.000 0.000 -18.71 0.00 0.00178.20130.80 RRUS-4449 B5/B12 3 6.411 7.052 0.5452.00 3.17 0.000 0.000 -22.34 0.00 0.00213.00140.80 RRUS-E2 3 6.411 7.052 0.6052.00 5.67 0.000 0.000 -39.99 0.00 0.00178.20150.80 PRK-1245L 1 6.411 7.052 1.0052.00 9.50 0.000 0.000 -67.00 0.00 0.00464.91161.00 RMV12_4XX 1 6.411 7.052 1.0052.00 29.95 0.000 0.000 -211.22 0.00 0.001357.77171.00 JAHH-65B-R3B 3 6.411 7.052 0.6652.00 18.15 0.000 0.000 -127.98 0.00 0.00189.90180.80 800-10965K 3 6.411 7.052 0.5752.00 23.53 0.000 0.000 -165.96 0.00 0.00325.80190.80 TPA-65R-BU6DA-K 3 6.411 7.052 0.5852.00 22.24 0.000 0.000 -156.84 0.00 0.00202.50200.80 Ericsson AIR6472 B77G B77M 3 6.467 7.114 0.6152.00 8.72 0.000 1.600 -62.02 0.00 -99.24231.48210.80 Shroud 1 6.210 6.831 1.0046.50 35.95 0.000 0.000 -245.56 0.00 0.001000.00221.00 -1,988.51Totals:8,176.76 Copyright 2025 by Tower Engineering Solutions, LLC. All rights reserved. Structure:CA45376-A-SBA Site Name:Mcarthur Height:58.00 (ft) 9/12/2025Code:TIA-222-H Exposure:B Base Elev:0.000 (ft) Total Applied Force Summary Page: 14IIStruct Class:Topography:1Gh:1.1 Crest Height:0.00 Site Class:D - Stiff Soil Dead Load Factor Wind Load Factor 1.00 1.00 18IterationsLoad Case:1.0D + 1.0W 60 mph Wind - Controlling Direction Elev (ft) Lateral FX (-) (lb) Axial FY (-) (lb) Torsion MY (lb-ft) Moment MZ (lb-ft)Description 0.00 0.00 0.000.00 0.00 -67.74 -367.44 0.005.00 0.00 -64.77 -355.11 0.0010.00 0.00 -61.81 -342.78 0.0015.00 0.00 -58.85 -330.45 0.0020.00 0.00 -55.89 -318.12 0.0025.00 0.00 -21.53 -123.79 0.0027.00 0.00 -31.98 -313.86 0.0030.00 0.00 -53.22 -297.31 0.0035.00 0.00 -52.08 -284.98 0.0040.00 0.00 -50.53 -272.65 0.0045.00 0.00 -260.21 -1079.39 0.0046.50 0.00(1) attachments -33.88 -180.93 0.0050.00 0.00 -948.47 -3896.43 0.0052.00 -99.24(31) attachments -249.98 -532.88 0.0054.50 0.00(7) attachments -4.61 -17.65 0.0055.00 0.00 -614.62 -3043.33 0.0058.00 0.00(22) attachments -2,630.16Totals:-11,757.0 9 0.00 -99.24 Copyright 2025 by Tower Engineering Solutions, LLC. All rights reserved. Structure:CA45376-A-SBA Site Name:Mcarthur Height:58.00 (ft) 9/12/2025Code:TIA-222-H Exposure:B Base Elev:0.000 (ft) Calculated Forces Page: 15IIStruct Class:Topography:1Gh:1.1 Crest Height:0.00 Site Class:D - Stiff Soil Dead Load Factor Wind Load Factor 1.00 1.00 18Load Case: 1.0D + 1.0W 60 mph Wind -Controlling Direction Iterations Seg Elev (ft) Pu FY (-) (kips) Vu FX (-) (kips) Mu MZ (ft-kips) Mu MX (ft-kips) Resultant Moment (ft-kips) phi Pn (kips) Total Deflect (in) Rotation Sway (deg) Stress Ratio Tu MY (-) (ft-kips) phi Vn (kips) phi Tn (ft-kips) phi Mn (ft-kips) Rotation Twist (deg) -11.75 -2.64 0.00 0.00 129.900.00 907.79 0.00 0.000 0.265-129.90 272.52 632.75 516.26 0.000 -11.38 -2.59 0.00 0.00 116.705.00 892.72 0.06 0.105 0.253-116.70 260.78 579.40 485.67 0.000 -11.02 -2.55 0.00 0.00 103.7310.00 875.48 0.22 0.213 0.241-103.73 249.03 528.40 454.70 0.000 -10.68 -2.51 0.00 0.00 90.9815.00 856.08 0.51 0.321 0.227-90.98 237.29 479.75 423.51 0.000 -10.34 -2.46 0.00 0.00 78.4620.00 834.51 0.90 0.431 0.213-78.46 225.55 433.45 392.25 0.000 -10.02 -2.42 0.00 0.00 66.1325.00 810.78 1.41 0.540 0.196-66.13 213.81 389.50 361.10 0.000 -9.89 -2.41 0.00 0.00 61.3027.00 800.68 1.65 0.585 0.188-61.30 209.11 372.57 348.71 0.000 -9.58 -2.38 0.00 0.00 54.0830.00 793.21 2.04 0.650 0.171-54.08 205.74 360.64 339.82 0.000 -9.28 -2.34 0.00 0.00 42.1535.00 765.83 2.77 0.751 0.149-42.15 194.00 320.65 309.20 0.000 -8.99 -2.30 0.00 0.00 30.4440.00 736.28 3.61 0.837 0.121-30.44 182.26 283.01 279.11 0.000 -8.72 -2.25 0.00 0.00 18.9445.00 704.56 4.53 0.907 0.088-18.94 170.51 247.72 249.71 0.000 -7.64 -1.98 0.00 0.00 15.5746.50 694.63 4.81 0.925 0.076-15.57 166.99 237.59 241.05 0.000 -7.46 -1.94 0.00 0.00 8.6550.00 666.85 5.51 0.957 0.051-8.65 158.77 214.78 219.90 0.000 -3.58 -0.93 0.00 0.00 4.6652.00 647.12 5.91 0.968 0.028-4.66 154.08 202.26 207.01 0.000 -3.05 -0.67 0.00 0.00 2.3454.50 622.46 6.42 0.976 0.017-2.34 148.21 187.14 191.45 0.000 -3.03 -0.67 0.00 0.00 2.0055.00 617.53 6.52 0.978 0.016-2.00 147.03 184.19 188.41 0.000 0.00 -0.61 0.00 0.00 0.0058.00 587.95 7.14 0.981 0.0000.00 139.99 166.96 170.68 0.000 Copyright 2025 by Tower Engineering Solutions, LLC. All rights reserved. Structure:CA45376-A-SBA Site Name:Mcarthur Height:58.00 (ft) 9/12/2025Code:TIA-222-H Exposure:B Base Elev:0.000 (ft) Seismic Segment Forces (Factored) Page: 16IIStruct Class:Topography:1Gh:1.1 Crest Height:0.00 Site Class:D - Stiff Soil Dead Load Factor Wind Load Factor 1.20 0.00 19Iterations Gust Response Factor 1.10 Seismic Load Factor Structure Frequency (f1) 1.00 0.52 Seismic Importance Factor S1 SsSds Sd1 SA 0.85 0.56 0.29 1.28 0.46 1.00 Load Case:1.2D + 1.0Ev + 1.0Eh Top Elev (ft)Description Wz (lb) Lateral Fs (lb)R:1.50 Vertical Ev (lb) Hz (lb) 0.000.00 0.000.000.00 384.925.00 0.1865.642.50 372.5910.00 1.1063.547.50 360.2615.00 2.5061.4412.50 347.9320.00 4.1859.3317.50 335.6025.00 6.0457.2322.50 Bot - Section 2 130.7927.00 1.5422.3026.00 Top - Section 1 324.3430.00 8.5455.3128.50 314.7935.00 10.1653.6832.50 302.4640.00 12.1151.5837.50 290.1345.00 13.9749.4842.50 Appurtenance(s)1084.6 3 46.50 151.08184.9745.75 193.1650.00 8.6632.9448.25 Appurtenance(s)3903.4 3 52.00 1624.83665.6651.00 Appurtenance(s)535.3854.50 58.5791.3053.25 18.0855.00 0.193.0854.75 Appurtenance(s)3045.9 1 58.00 1266.67519.4356.50 Totals:11,944.4 3,170.3 -7,363.1Total Wind:2,036.9 Copyright 2025 by Tower Engineering Solutions, LLC. All rights reserved. Structure:CA45376-A-SBA Site Name:Mcarthur Height:58.00 (ft) 9/12/2025Code:TIA-222-H Exposure:B Base Elev:0.000 (ft) Calculated Forces Page: 17IIStruct Class:Topography:1Gh:1.1 Crest Height:0.00 Site Class:D - Stiff Soil Dead Load Factor Wind Load Factor 1.20 0.00 19Iterations Gust Response Factor 1.10 Seismic Load Factor Structure Frequency (f1) 1.00 0.52 Seismic Importance Factor S1 SsSds Sd1 SA 0.85 0.56 0.29 1.28 0.46 1.00 Load Case:1.2D + 1.0Ev + 1.0Eh Seg Elev (ft) Pu FY (-) (kips) Vu FX (-) (kips) Mu MZ (ft-kips) Mu MX (ft-kips) Resultant Moment (ft-kips) phi Pn (kips) Total Deflect (in) Rotation Sway (deg) Stress Ratio Tu MY (-) (ft-kips) phi Vn (kips) phi Tn (ft-kips) phi Mn (ft-kips) Rotation Twist (deg) -16.14 3.19 0.00 0.00 180.550.00 907.79 0.00 0.00 0.368180.55 272.52 632.75 516.26 -15.63 3.23 0.00 0.00 164.605.00 892.72 0.08 0.15 0.357164.60 260.78 579.40 485.67 -15.13 3.27 0.00 0.00 148.4410.00 875.48 0.32 0.30 0.344148.44 249.03 528.40 454.70 -14.65 3.30 0.00 0.00 132.0915.00 856.08 0.71 0.46 0.329132.09 237.29 479.75 423.51 -14.18 3.34 0.00 0.00 115.5720.00 834.51 1.28 0.62 0.312115.57 225.55 433.45 392.25 -13.74 3.35 0.00 0.00 98.9025.00 810.78 2.01 0.78 0.29198.90 213.81 389.50 361.10 -13.56 3.37 0.00 0.00 92.1927.00 800.68 2.35 0.85 0.28292.19 209.11 372.57 348.71 -13.12 3.38 0.00 0.00 82.0930.00 793.21 2.92 0.94 0.25882.09 205.74 360.64 339.82 -12.70 3.40 0.00 0.00 65.1935.00 765.83 3.99 1.10 0.22865.19 194.00 320.65 309.20 -12.30 3.40 0.00 0.00 48.2140.00 736.28 5.21 1.23 0.19048.21 182.26 283.01 279.11 -11.92 3.39 0.00 0.00 31.1945.00 704.56 6.57 1.35 0.14231.19 170.51 247.72 249.71 -10.44 3.22 0.00 0.00 26.1046.50 694.63 7.00 1.38 0.12426.10 166.99 237.59 241.05 -10.19 3.21 0.00 0.00 14.8550.00 666.85 8.03 1.43 0.08314.85 158.77 214.78 219.90 -4.89 1.45 0.00 0.00 8.4352.00 647.12 8.63 1.45 0.0488.43 154.08 202.26 207.01 -4.16 1.37 0.00 0.00 4.8154.50 622.46 9.40 1.46 0.0324.81 148.21 187.14 191.45 -4.14 1.37 0.00 0.00 4.1255.00 617.53 9.55 1.47 0.0294.12 147.03 184.19 188.41 0.00 1.27 0.00 0.00 0.0058.00 587.95 10.47 1.47 0.0000.00 139.99 166.96 170.68 Copyright 2025 by Tower Engineering Solutions, LLC. All rights reserved. Structure:CA45376-A-SBA Site Name:Mcarthur Height:58.00 (ft) 9/12/2025Code:TIA-222-H Exposure:B Base Elev:0.000 (ft) Seismic Segment Forces (Factored) Page: 18IIStruct Class:Topography:1Gh:1.1 Crest Height:0.00 Site Class:D - Stiff Soil Dead Load Factor Wind Load Factor 0.90 0.00 19Iterations Gust Response Factor 1.10 Seismic Load Factor Structure Frequency (f1) 1.00 0.52 Seismic Importance Factor S1 SsSds Sd1 SA 0.85 0.56 0.29 1.28 0.46 1.00 Load Case:0.9D + 1.0Ev + 1.0Eh Top Elev (ft)Description Wz (lb) Lateral Fs (lb)R:1.50 Vertical Ev (lb) Hz (lb) 0.000.00 0.000.000.00 358.705.00 0.1661.172.50 346.3710.00 0.9859.077.50 334.0415.00 2.2156.9612.50 321.7120.00 3.6854.8617.50 309.3825.00 5.2952.7622.50 Bot - Section 2 120.3027.00 1.3520.5126.00 Top - Section 1 308.6130.00 7.9052.6328.50 288.5735.00 8.8149.2132.50 276.2440.00 10.4547.1137.50 263.9145.00 11.9745.0042.50 Appurtenance(s)1076.7 7 46.50 150.26183.6245.75 174.8150.00 7.3529.8148.25 Appurtenance(s)3892.9 4 52.00 1628.70663.8851.00 Appurtenance(s)531.6354.50 58.2890.6653.25 17.4455.00 0.182.9754.75 Appurtenance(s)3042.0 4 58.00 1272.77518.7756.50 Totals:11,663.4 3,170.3 -7,363.1Total Wind:1,989.0 Copyright 2025 by Tower Engineering Solutions, LLC. All rights reserved. Structure:CA45376-A-SBA Site Name:Mcarthur Height:58.00 (ft) 9/12/2025Code:TIA-222-H Exposure:B Base Elev:0.000 (ft) Calculated Forces Page: 19IIStruct Class:Topography:1Gh:1.1 Crest Height:0.00 Site Class:D - Stiff Soil Dead Load Factor Wind Load Factor 0.90 0.00 19Iterations Gust Response Factor 1.10 Seismic Load Factor Structure Frequency (f1) 1.00 0.52 Seismic Importance Factor S1 SsSds Sd1 SA 0.85 0.56 0.29 1.28 0.46 1.00 Load Case:0.9D + 1.0Ev + 1.0Eh Seg Elev (ft) Pu FY (-) (kips) Vu FX (-) (kips) Mu MZ (ft-kips) Mu MX (ft-kips) Resultant Moment (ft-kips) phi Pn (kips) Total Deflect (in) Rotation Sway (deg) Stress Ratio Tu MY (-) (ft-kips) phi Vn (kips) phi Tn (ft-kips) phi Mn (ft-kips) Rotation Twist (deg) -12.57 3.19 0.00 0.00 178.430.00 907.79 0.00 0.00 0.360178.43 272.52 632.75 516.26 -12.17 3.22 0.00 0.00 162.505.00 892.72 0.08 0.15 0.348162.50 260.78 579.40 485.67 -11.78 3.25 0.00 0.00 146.4210.00 875.48 0.31 0.30 0.336146.42 249.03 528.40 454.70 -11.40 3.27 0.00 0.00 130.1915.00 856.08 0.70 0.45 0.321130.19 237.29 479.75 423.51 -11.04 3.30 0.00 0.00 113.8220.00 834.51 1.26 0.61 0.304113.82 225.55 433.45 392.25 -10.70 3.31 0.00 0.00 97.3425.00 810.78 1.99 0.77 0.28397.34 213.81 389.50 361.10 -10.56 3.32 0.00 0.00 90.7227.00 800.68 2.32 0.83 0.27490.72 209.11 372.57 348.71 -10.22 3.33 0.00 0.00 80.7630.00 793.21 2.88 0.93 0.25180.76 205.74 360.64 339.82 -9.89 3.34 0.00 0.00 64.1235.00 765.83 3.93 1.08 0.22164.12 194.00 320.65 309.20 -9.58 3.34 0.00 0.00 47.4240.00 736.28 5.14 1.21 0.18347.42 182.26 283.01 279.11 -9.29 3.34 0.00 0.00 30.7045.00 704.56 6.48 1.33 0.13730.70 170.51 247.72 249.71 -8.14 3.16 0.00 0.00 25.7046.50 694.63 6.90 1.36 0.11925.70 166.99 237.59 241.05 -7.94 3.16 0.00 0.00 14.6250.00 666.85 7.91 1.41 0.07914.62 158.77 214.78 219.90 -3.81 1.43 0.00 0.00 8.3152.00 647.12 8.51 1.43 0.0468.31 154.08 202.26 207.01 -3.24 1.36 0.00 0.00 4.7454.50 622.46 9.26 1.44 0.0304.74 148.21 187.14 191.45 -3.22 1.35 0.00 0.00 4.0655.00 617.53 9.41 1.45 0.0274.06 147.03 184.19 188.41 0.00 1.27 0.00 0.00 0.0058.00 587.95 10.32 1.45 0.0000.00 139.99 166.96 170.68 Copyright 2025 by Tower Engineering Solutions, LLC. All rights reserved. Structure:CA45376-A-SBA Site Name:Mcarthur Height:58.00 (ft) 9/12/2025Code:TIA-222-H Exposure:B Base Elev:0.000 (ft) Final Analysis Summary Page: 20IIStruct Class:Topography:1Gh:1.1 Crest Height:0.00 Site Class:D - Stiff Soil Reactions Load Case Shear FX (kips) Shear FZ (kips) Axial FY (kips) Moment MX (ft-kips) Moment MY (ft-kips) Moment MZ (ft-kips) 7.4 0.00 14.09 0.00 0.001.2D + 1.0W 95 mph Wind 366.45 6.4 3.70 14.09 183.24 0.001.2D + 1.0W 95 mph Wind at 30°317.38 3.7 6.41 14.09 317.38 0.001.2D + 1.0W 95 mph Wind at 60°183.24 0.0 7.40 14.09 366.45 0.001.2D + 1.0W 95 mph Wind at 90°0.00 3.7 6.41 14.09 317.38 0.001.2D + 1.0W 95 mph Wind at 120°183.24 6.4 3.70 14.09 183.24 0.001.2D + 1.0W 95 mph Wind at 150°317.38 7.4 0.00 14.09 0.00 0.001.2D + 1.0W 95 mph Wind at 180°366.45 6.4 3.70 14.09 183.24 0.001.2D + 1.0W 95 mph Wind at 210°317.38 3.7 6.41 14.09 317.38 0.001.2D + 1.0W 95 mph Wind at 240°183.24 0.0 7.40 14.09 366.45 0.001.2D + 1.0W 95 mph Wind at 270°0.00 3.7 6.41 14.09 317.38 0.001.2D + 1.0W 95 mph Wind at 300°183.24 6.4 3.70 14.09 183.24 0.001.2D + 1.0W 95 mph Wind at 330°317.38 7.4 0.00 10.56 0.00 0.000.9D + 1.0W 95 mph Wind 362.07 6.4 3.70 10.56 181.04 0.000.9D + 1.0W 95 mph Wind at 30°313.58 3.7 6.40 10.56 313.58 0.000.9D + 1.0W 95 mph Wind at 60°181.04 0.0 7.39 10.56 362.07 0.000.9D + 1.0W 95 mph Wind at 90°0.00 3.7 6.40 10.56 313.58 0.000.9D + 1.0W 95 mph Wind at 120°181.04 6.4 3.70 10.56 181.04 0.000.9D + 1.0W 95 mph Wind at 150°313.58 7.4 0.00 10.56 0.00 0.000.9D + 1.0W 95 mph Wind at 180°362.07 6.4 3.70 10.56 181.04 0.000.9D + 1.0W 95 mph Wind at 210°313.58 3.7 6.40 10.56 313.58 0.000.9D + 1.0W 95 mph Wind at 240°181.04 0.0 7.39 10.56 362.07 0.000.9D + 1.0W 95 mph Wind at 270°0.00 3.7 6.40 10.56 313.58 0.000.9D + 1.0W 95 mph Wind at 300°181.04 6.4 3.70 10.56 181.04 0.000.9D + 1.0W 95 mph Wind at 330°313.58 2.6 0.00 11.75 0.00 0.001.0D + 1.0W 60 mph Wind 129.90 2.3 1.32 11.75 64.95 0.001.0D + 1.0W 60 mph Wind at 30°112.49 1.3 2.29 11.75 112.49 0.001.0D + 1.0W 60 mph Wind at 60°64.95 0.0 2.64 11.75 129.90 0.001.0D + 1.0W 60 mph Wind at 90°0.00 1.3 2.29 11.75 112.49 0.001.0D + 1.0W 60 mph Wind at 120°64.95 2.3 1.32 11.75 64.95 0.001.0D + 1.0W 60 mph Wind at 150°112.49 2.6 0.00 11.75 0.00 0.001.0D + 1.0W 60 mph Wind at 180°129.90 2.3 1.32 11.75 64.95 0.001.0D + 1.0W 60 mph Wind at 210°112.49 1.3 2.29 11.75 112.49 0.001.0D + 1.0W 60 mph Wind at 240°64.95 0.0 2.64 11.75 129.90 0.001.0D + 1.0W 60 mph Wind at 270°0.00 1.3 2.29 11.75 112.49 0.001.0D + 1.0W 60 mph Wind at 300°64.95 2.3 1.32 11.75 64.95 0.001.0D + 1.0W 60 mph Wind at 330°112.49 3.2 0.00 16.14 0.00 0.001.2D + 1.0Ev + 1.0Eh 180.55 3.2 0.00 12.57 0.00 0.000.9D + 1.0Ev + 1.0Eh 178.43 Elev (ft) Stress Ratio Max Stresses Load Case Pu FY (-) (kips) Vu FX (-) (kips) Tu MY (-) (ft-kips) Mu MZ (ft-kips) Mu MX (ft-kips) Resultant Moment (ft-kips) phi Pn (kips) phi Vn (kips) phi Tn (ft-kips) phi Mn (ft-kips) 0.00 0.7261.2D + 1.0W 95 mph Wind -14.09 -7.40 0.00 366.450.00-366.45 907.79 272.52 632.75 516.26 0.00 0.7261.2D + 1.0W 95 mph Wind at 30°-14.09 -6.41 0.00 366.47-183.24-317.38 907.79 272.52 632.75 516.26 0.00 0.7261.2D + 1.0W 95 mph Wind at 60°-14.09 -3.70 0.00 366.47-317.38-183.24 907.79 272.52 632.75 516.26 Copyright 2025 by Tower Engineering Solutions, LLC. All rights reserved. Structure:CA45376-A-SBA Site Name:Mcarthur Height:58.00 (ft) 9/12/2025Code:TIA-222-H Exposure:B Base Elev:0.000 (ft) Final Analysis Summary Page: 21IIStruct Class:Topography:1Gh:1.1 Crest Height:0.00 Site Class:D - Stiff Soil Reactions Load Case Shear FX (kips) Shear FZ (kips) Axial FY (kips) Moment MX (ft-kips) Moment MY (ft-kips) Moment MZ (ft-kips) 0.00 0.7261.2D + 1.0W 95 mph Wind at 90°-14.09 0.00 0.00 366.45-366.450.00 907.79 272.52 632.75 516.26 0.00 0.7261.2D + 1.0W 95 mph Wind at 120°-14.09 3.70 0.00 366.47-317.38183.24 907.79 272.52 632.75 516.26 0.00 0.7261.2D + 1.0W 95 mph Wind at 150°-14.09 6.41 0.00 366.47-183.24317.38 907.79 272.52 632.75 516.26 0.00 0.7261.2D + 1.0W 95 mph Wind at 180°-14.09 7.40 0.00 366.450.00366.45 907.79 272.52 632.75 516.26 0.00 0.7261.2D + 1.0W 95 mph Wind at 210°-14.09 6.41 0.00 366.47183.24317.38 907.79 272.52 632.75 516.26 0.00 0.7261.2D + 1.0W 95 mph Wind at 240°-14.09 3.70 0.00 366.47317.38183.24 907.79 272.52 632.75 516.26 0.00 0.7261.2D + 1.0W 95 mph Wind at 270°-14.09 0.00 0.00 366.45366.450.00 907.79 272.52 632.75 516.26 0.00 0.7261.2D + 1.0W 95 mph Wind at 300°-14.09 -3.70 0.00 366.47317.38-183.24 907.79 272.52 632.75 516.26 0.00 0.7261.2D + 1.0W 95 mph Wind at 330°-14.09 -6.41 0.00 366.47183.24-317.38 907.79 272.52 632.75 516.26 0.00 0.7140.9D + 1.0W 95 mph Wind -10.56 -7.39 0.00 362.070.00-362.07 907.79 272.52 632.75 516.26 0.00 0.7140.9D + 1.0W 95 mph Wind at 30°-10.56 -6.40 0.00 362.09-181.04-313.58 907.79 272.52 632.75 516.26 0.00 0.7140.9D + 1.0W 95 mph Wind at 60°-10.56 -3.70 0.00 362.09-313.58-181.04 907.79 272.52 632.75 516.26 0.00 0.7140.9D + 1.0W 95 mph Wind at 90°-10.56 0.00 0.00 362.07-362.070.00 907.79 272.52 632.75 516.26 0.00 0.7140.9D + 1.0W 95 mph Wind at 120°-10.56 3.70 0.00 362.09-313.58181.04 907.79 272.52 632.75 516.26 0.00 0.7140.9D + 1.0W 95 mph Wind at 150°-10.56 6.40 0.00 362.09-181.04313.58 907.79 272.52 632.75 516.26 0.00 0.7140.9D + 1.0W 95 mph Wind at 180°-10.56 7.39 0.00 362.070.00362.07 907.79 272.52 632.75 516.26 0.00 0.7140.9D + 1.0W 95 mph Wind at 210°-10.56 6.40 0.00 362.09181.04313.58 907.79 272.52 632.75 516.26 0.00 0.7140.9D + 1.0W 95 mph Wind at 240°-10.56 3.70 0.00 362.09313.58181.04 907.79 272.52 632.75 516.26 0.00 0.7140.9D + 1.0W 95 mph Wind at 270°-10.56 0.00 0.00 362.07362.070.00 907.79 272.52 632.75 516.26 0.00 0.7140.9D + 1.0W 95 mph Wind at 300°-10.56 -3.70 0.00 362.09313.58-181.04 907.79 272.52 632.75 516.26 0.00 0.7140.9D + 1.0W 95 mph Wind at 330°-10.56 -6.40 0.00 362.09181.04-313.58 907.79 272.52 632.75 516.26 0.00 0.2651.0D + 1.0W 60 mph Wind -11.75 -2.64 0.00 129.900.00-129.90 907.79 272.52 632.75 516.26 0.00 0.2651.0D + 1.0W 60 mph Wind at 30°-11.75 -2.29 0.00 129.90-64.95-112.49 907.79 272.52 632.75 516.26 0.00 0.2651.0D + 1.0W 60 mph Wind at 60°-11.75 -1.32 0.00 129.90-112.49-64.95 907.79 272.52 632.75 516.26 0.00 0.2651.0D + 1.0W 60 mph Wind at 90°-11.75 0.00 0.00 129.90-129.900.00 907.79 272.52 632.75 516.26 0.00 0.2651.0D + 1.0W 60 mph Wind at 120°-11.75 1.32 0.00 129.90-112.4964.95 907.79 272.52 632.75 516.26 0.00 0.2651.0D + 1.0W 60 mph Wind at 150°-11.75 2.29 0.00 129.90-64.95112.49 907.79 272.52 632.75 516.26 0.00 0.2651.0D + 1.0W 60 mph Wind at 180°-11.75 2.64 0.00 129.900.00129.90 907.79 272.52 632.75 516.26 0.00 0.2651.0D + 1.0W 60 mph Wind at 210°-11.75 2.29 0.00 129.9064.95112.49 907.79 272.52 632.75 516.26 0.00 0.2651.0D + 1.0W 60 mph Wind at 240°-11.75 1.32 0.00 129.90112.4964.95 907.79 272.52 632.75 516.26 0.00 0.2651.0D + 1.0W 60 mph Wind at 270°-11.75 0.00 0.00 129.90129.900.00 907.79 272.52 632.75 516.26 0.00 0.2651.0D + 1.0W 60 mph Wind at 300°-11.75 -1.32 0.00 129.90112.49-64.95 907.79 272.52 632.75 516.26 0.00 0.2651.0D + 1.0W 60 mph Wind at 330°-11.75 -2.29 0.00 129.9064.95-112.49 907.79 272.52 632.75 516.26 0.00 0.3681.2D + 1.0Ev + 1.0Eh -16.14 3.19 0.00 180.550.00180.55 907.79 272.52 632.75 516.26 0.00 0.3600.9D + 1.0Ev + 1.0Eh -12.57 3.19 0.00 178.430.00178.43 907.79 272.52 632.75 516.26 Serviceability: 0.342 Copyright 2025 by Tower Engineering Solutions, LLC. All rights reserved. Structure:CA45376-A-SB ASite Name:Mcarthur Height:58.00 (ft) 9/12/2025Code:TIA-222-H Exposure:B Base Elev:0.000 (ft) Base Plate Summary Page: 22IIStruct Class:Topography:1Gh:1.1 Crest Height:0.00 Site Class:D - Stiff Soil Reactions Moment (kip-ft):400.00 Original Design Analysis (1.2D + 1.0W 60° Wind) Moment (kip-ft):366.47 Axial (kip): Shear (kip): 9.00 10.00 Axial (kip):14.09 Shear (kip):7.40 Base Plate Yield (ksi):50.00 Width (in):31.00 Style:Square Polygon Sides:0.00 Clip Length (in):0.00 Effective Len (in):24.01 Moment (kip-in):499.58 Allow Stress (ksi):67.50 Applied Stress (ksi):20.25 Stress Ratio:0.30 Anchor Bolts Bolt Circle:36.00 Compression Tension Number Bolts:4.00 Bolt Type:2.25" 18J Bolt Diameter (in):2.25 Yield (ksi):75.00 Ultimate (ksi):100.00 Arrangement:Clustered Cluster Dist (in):6.00 Start Angle (deg):45.00 Force (kip):125.68 Allowable (kip):268.39 Ratio:0.47 Force (kip):118.64 Allowable (kip):243.75 Ratio:0.49 Copyright 2025 by Tower Engineering Solutions, LLC. All rights reserved. Customer Name: Site Name: Site Number: Engr. Number: Foundation Info Obtained from:Acceptable overstress (5.0% 1.00 ft. Axial Load (Kips):14.1 Shear Force (Kips):7.4 Uplift Force (Kips):0.0 Moment (Kips-ft):366.5 16.0 ft.( 31) #10 rebar Foundation Geometries:( 27) #4 ties 5.5 Depth of Base B. G. S. :19.7 ft.19.7 ft. Pier Height A. G. (ft.):1.00 5.5 ft. Concrete Strength (psi):3000 Steel Elastic Modulus:29000 ksi Vertical bar yield (ksi)60 Tie steel yield strength:60 ksi ( 31) #10 rebar 5.5 ft. ɸ Pier Vertical Rebar Size #:10 Tie / Stirrup Size #:4 ( 27) #4 ties Qty. of Vertical Rebars:31 Tie Spacing:12.0 in. Concrete Cover (in.):3 Concrete unit weight:150.0 pcf Soil Design Parameters: Water Table B.G.S. (ft):16.0 Unit weight of water:62.4 psf Ratio of Uplift/Axial Skin Friction:1.0 Pullout failure Angle:30 (°) Skin Frictions are to be obtained from: Soil Report γsoil φ Cohesion Top Bottom (pcf)(°)(psf) 0.0 3.0 100 0 0 Clay 3.0 10.0 110 0 350 Clay 10.0 19.7 100 30 0 Sand 19.7 24.7 100 0.0 0.0 0.0 0.0 0.0 0.0 1.1 Foundation Analysis and Design: Uplift Strength Reduction Factor:0.75 Soil Bearing Strength Reduction Factor:0.75 4495 Dry Soil Weight from Conical Failure:469 Kips 86 Buoyant Soil Weight from Conical Failure (K 5 Kips Total Dry Concrete Volume (cu. Ft.):404 Total Dry Concrete Weight:60.6 Kips 87.9 Total Buoyant Concrete Weight:7.70 Kips 68.3 Total Effective Soil Weight:473.7 Kips Total Effective Vertical Load on Base (Kips):38.1 EIA/TIA Standard: Structure Height (Ft.):58 CA45376-A-SBA J. Tibbetts Engineer Login ID:TES 9/11/2025Pier Foundation Design For Monopole Date Engineer Name: Structure Type: Soil weight Increase Factor for bouyant soils (1.0 to 1.15): Soil Types TIA-222-HAT&T 162721 Analysis or Design? Material Properties and Reabr Info: Drawings/Calculations Total Buoyant Concrete Volume (cu. Ft.): Total Effective Concrete Weight (Kips): Analysis Total Buoyant Soil Volume from Conical Failure (cu. Ft.): Base Reactions (Factored): Monopole Diameter of Pier (ft.): Depth of Layers (ft) Total Dry Soil Volume from Conical Failure (cu. Ft.): Ultimate Bearing (psf) 1000 5.5 ft. Monopole Pier Foundation Ultimate Skin Friction (psf) TES Engr. Number:Page 2/2 Date: Usage Allowable Foundation Overturning Resistance (kips-ft.):2132.8 >Design Factored Moment (kips-ft): 473 0.22 OK! Factor of Safety of Passive Soil Resistance against Moment:4.51 OK! Check the capacities of Reinforceing Concrete: Strength reduction factor (Flexure and axial tension):0.90 Strength reduction factor (Shear):0.75 Strength reduction factor (Axial compresion):0.65 Wind Load Factor on Concrete Design:1.00 Reinforcing Concrete Pier:Usage Vertical Steel Rebar Area (sq. in./each): 1.27 Tie / Stirrup Area (sq. in./each):0.20 Calculated Moment Capacity (Mn,Kips-Ft):4706.8 >Design Factored Moment (Mu, K-Ft):396.5 0.08 OK! Calculated Shear Capacity (Kips):591.9 >Design Factored Shear (Kips):52.6 0.09 OK! Calculated Tension Capacity (Tn, Kips):2126.0 >Design Factored Tension (Tu Kips):0.0 0.00 OK! Calculated Compression Capacity (Pn, Kips):4484 >Design Factored Axial Load (Pu Kips):14.1 0.00 OK! Moment & Axial Strength Combination:0.08 OK!Max. Allowable Tie/Stirrup Spacing:12.00 in. Pier Reinforcement Ratio:0.012 9/11/2025 Check Soil Capacities: Reinforcement Ratio is satisfied per ACI 162721