HomeMy WebLinkAbout1525 W Marion Way - REV2 - Plan:: ROOF NOTE SCHEDULE ::
(N) DOWNSPOUT; TYP.
(N) GUTTER; MATCH (E) STYLE; TYP.
GUTTER SLOPE DIRECTION; TYP.
VULCAN VENT VE3514 TABBED EAVE VENT
USED WITH EVERKEM FIRE CAULKING ICC-
ESL:1300; TYP.
ASPHALT SHINGLE - CLASS A FIRE RESISTANCE.
TRUDEFINITION DURATION COOL SHINGLES
COLOR MOUNTAINSIDE (OR SIMILAR). PRI ER-
1378E01
INTAKE VENTILATION TO BE GAF COBRA
INTAKE PRO (OR SIMILAR) INSTALL PER
MANFU. SPECS
ROOF VENTILATION EXHAUST TO BE GAF IR65
PLASTIC SLANT - BACK (OR SIMILAR)
INSTALLED BASED ON MANF. SPECS AND IN
POSITION NOTED ON PLAN
IMAGINARY PROPERTY SEPARATION LINE.
11
22
33
44
55
66
77
88
11
22
33
44
55
66
77
88
5 : 12
5 : 12
5 : 12
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L P / L P / L P / L P / L P / L P / L P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L P / L P / L P / L P / L P / L P / L
SB / L SB / L SB / L SB / L SB / L
SB / L
SB / L
SB / L
SB / L
SB / L
SB / L
SB / L
SB / L SB / L SB / L SB / L SB / L
SB / L
SB / L
SB / L
SB / L
SB / L
SB / L
SB / L
5 : 12
5 : 12
5 : 12 5 : 12
5 : 125 : 12
5 : 125 : 12
1 : 12
8'
96"
MAIN RESIDENCE
2314 SPRUCE ST
(E) GARAGE
2314 SPRUCE ST
22
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L P / L P / L P / L P / L P / L P / L P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L
P / L P / L P / L P / L P / L P / L P / L
SB / L SB / L SB / L SB / L SB / L
SB / L
SB / L
SB / L
SB / L
SB / L
SB / L
SB / L
SB / L SB / L SB / L SB / L SB / L
SB / L
SB / L
SB / L
SB / L
SB / L
SB / L
SB / L
5 : 12
5 : 12
5 : 12 5 : 12
5 : 12
5 : 12
5 : 12
5 : 12
5 : 12
5 : 12 5 : 12
5 : 12
5 : 125 : 12
1 : 12
5 : 12
12.5'18.5'19'
18'-8"
224"
6'
72"
4'
48"
1'
12"
17'-3"
207"
1'
12"
13.68'
25.22'
10'
8'
10'
5'5'
6'
15'
CL
14'-4 1/2"
173"
11'-3 3/4"
136"
3'
5'
2'
2'
1'
2'
11223344
MAIN RESIDENCE
2314 SPRUCE ST
(N) ADU
1525 W. MARION WAY
55
66
7777
55
88
11
22
88
22
11
11
0 1 5 10
Scale: 3/16"=1'
2 3 4 20 0 1 5 10
Scale: 3/16"=1'
2 3 4 20
ROOFING MEMBRANE
2x WOOD RAFTERS
VENTED AIRSPACE
BAFFLE
VAPOR BARRIER
FINISH SIDING
FINISH ROOFING
EAVE BLOCKING w/
FIRE VENT SEE MANUF.
SHEATHING
INSULATION
FLASHING
RIDGE BOARD (drilled or notched)
5/8 Gyp. Type X
1/2 in OSB
3/4" STUCCO FINISH
1-SI DDED LP
FLAMEBLOCK
2 LAYERS WATER
RESISTANT BARRIER;
30LB FELT MIN.
DECK-TO-WALL
METAL FLASHINNG
BUILDING PAPER
LAPPED IN
WEATHERBOARD
FASHI ON. LAP OVER
FLEXI BLE FLASHING
AT HEAD.
LATH AND PLASTER
5/8" GYP. TYPE X ON
I NTERIOR SIDE OF WALL
REVISION TABLE
#
DATE
REVISED
BY
DESCRIPTION
1
2/22/2025
KDS
OWNER REQUEST
2
7/28/2025
KDS
INSPECTION REV
GENERAL NOTES
3/16" = 1'
1.Dimensions are for initial building estimates
only. It is the responsibility of the Contractor
to field verify the dimensions before any
construction begins.
2.(E) GUTTER AND DOWNSPOUT TO REMAIN;
REPAIR AS NECESSARY
3.ROOF SLOPE IS 5:12 UNO
4.(N) Roof to match (E) in style, color, and
orientation.
5.(N) Roof eave over hang is 12in UNO
Current File located at: G:/Shared drives/Work Drive/1 - Clients/2023/111 Green Bay Construction 111/GB2305_ADU_Spruce/10-Chief Architect/GB2305_ADU_Spruce.layout
ATTI C SF to VENTILATION SF = 150:1
PROPOSED ATTIC* SF = 565
REQUIRED VENTILATION = 272square inches of
intake+exhaust
Ventilation intake to be:
Fire rated Vulcan Vents VE3514
Ventilation exhaust to be:
Master Flow IR65
:: ROOF VENTILATION ::
:: CALCULATIONS ::
Existing Roof Plan1 Proposed Roof Plan1
EXISTING ROOF
PLAN
1 1HR FIRE RATED EXPOSED RAFTERS
2 1HR FIRE EXTERIOR WALL - U348
22
22
WALLS LESS THAN 5 FEET FROM PROPERTY LINES,
REAL OR IMAGINARY, SHALL COMPLY WITH DETAIL
2/A101; EAVE OVERHANGS LESS THAN 5 FEET FROM
PROPERTY LINES, REAL OR IMAGINARY, SHALL
COMPLY WITH DETAIL 1/A101
GARAGE CONVERSION
SHEET:
SCALE:
:: DRAWINGS PROVIDED BY ::
Kurt D Snyder
Green Bay Remodeling
1 9 4 9 3 7 8 3 3 5 8
1525 W MARION WAY
SANTA ANA, CA 92706
DATE:
4/9/2026
A 1 0 1
D03D03
D06D06
W05W05
D01D01
W01W01
D04D04
D07D07
3068
W02W02
D02D02
W04W04
D05D05
21068
4040LS
4040LS
6068
W03W03 W03W03
D03D03
110V
110V
110V
110V
110V
110V
110V
110V
110V 110 V 110V
110V
C / W C / W C / W
S S S S S
S
S
S
30X22
ATTIC
ACCESS
30X22
ATTIC
ACCESS
110V
R4
GFCI
DM
DM
DM
DM
R4
R4
GFCI
GFCI
GFCI GFCI
GFCI
H
VS
R4
R4R4
R4
R4
R4
R4
R4
DM
DM
R4
R4
R4
R4
R4
R4
DW
GD
HV
R
RA
GFCI
DM
DM
DM
CO/SD
CO/SD
EP
CO/SD
1
A102
1
A102
2
A102
2
A102
2
A102
2
A102
3
A102
3
A102
3
A102
3
A102
1
A103
1
A103
3
A103
3
A103
4
A103
4
A103
5
A103
5
A103
9'-2"
6'-9 1/2"
6'-10"
2'-1 1/2"
10'-6"
8'-9 1/2"
1'-10"
3'-7"
2'-1"
5'-6"10'-5"
37'-6"
17'-3"
6'-0 1/2"
3'
2'-4"
12'-7"
2'-4"
3'-3 1/2"
2'-6"
12'-8"
18'-6"
2'-1 1/2"
3'
3'
3'
9'-3"
3 1/2"
12'-3 1/2"
60"
33"
24"
30"
36"21"18"
69"18"
3"
25"43"22"
12"9"
149 3/4"
43"
131"
37'-6"
10'-5" X 13'-0"
125 SQ FT
16'-4" X 9'-2"
148 SQ FT
5'-6" X 10'-6"
58 SQ FT
16'-4" X 16'-1"
245 SQ FT
LIVING
KITCHEN/DINNING
BEDROOM
BATH
11
22
33
44
33
55
66 77
88
2%
99
1-1/2"
1-1/2"
1-1/2"
1010
37' 6"
11
80"
72 15/16"
152 15/16"
8'
R-38, typ. for attic
R-19, typ. for exterior walls
80"
72 15/16"
152 15/16"
8'
R-38, typ. for attic
R-19, typ. for exterior walls
R-38, typ. for Attic
R-19, typ. for exterior walls
R-38, typ. for Attic
R-19, typ. for exterior walls
7'-10 1/2"
R-19, typ. for
exterior walls7'-10 1/2"
R-19, typ. for
exterior walls
:: FLOOR PLAN NOTE SCHEDULE ::
SMALL EFFICIENCY LAUNDRY CENTER
TANKLESS W.H. PER T-24
FLOORING TBD
BATHROOM FLOORING TBD
CURBLESS SHOWER ENTRY
ENTRY DOOR; DOORBELL BUTTON SHALL NOT
BE INSTALLED MORE THAN 48" ABOVE
EXTERIOR FLOOR OR LANDING.
(N) AC CONDENSER
ALL INTERIOR WALLS TO BE REINFORCED
ACCORDING TO THE AGING-IN-PLACE
PROVISIONS OUTLINED IN 2022 CRC 327.1.1
NO GAS HOOK UP AT STOVE.
REINFORCEMENT MUST BE INSTALLED IN AT
LEAST ONE BATHROOM ON THE ENTRY LEVEL
OR, IF NONE, ON THE SECOND OR THIRD
FLOOR, USING SOLID LUMBER OR
EQUIVALENT MATERIALS NO LESS THAN 2 BY 8
INCHES (NOMINAL SIZE). REINFORCEMENT
SHOULD BE LOCATED 32 TO 39 1/4 INCHES
ABOVE THE FLOOR, INSTALLED ON CALLED
OUT WALLS FOR WATER CLOSETS, SHOWERS,
AND BATHTUBS AS DETAILED.
11
22
33
44
55
66
77
88
99
1010
11
22
33
44
55
66
77
88
99
1010
WALL SCHEDULE
WALL TYPE(S)
(N) INTERIOR-4
(N) STUCCO-4
(E) STUCCO-4
(E) STUCCO-4, SHORT
REVISION TABLE
#
DATE
REVISED
BY
DESCRIPTION
1
2/22/2025
KDS
OWNER REQUEST
2
7/28/2025
KDS
INSPECTION REV
3/8" = 1'
KEY NOTES
GENERAL NOTES
LEGEND
1.Dimensions are for initial building estimates
only. It is the responsibility of the Contractor
to field verify the dimensions before any
construction begins.
2.(E) GUTTER AND DOWNSPOUT TO REMAIN;
REPAIR AS NECESSARY
3.ROOF SLOPE IS 5:12 UNO
4.(N) Door and Windows are called out with
the associated tags. (E) Doors and
Windows are shown only as their (E) sizes
BATH 1 =150SF
LIGHT = 6SF (4%)
VENTILATION = 3SF (2%)
BEDROOM =116SF
LI GHT = 53SF (45%)
VENTILATION = 27SF (23%)
KITCHEN/LI VING =205SF
LI GHT = 49SF (23%)
VENTILATION = 25SF (12%)
MAN CAVE =156SF
LI GHT = 65SF (41%)
VENTILATION = 33SF (20%)
:: ROOM LIGHT+VENT ::
:: CALCULATIONS ::
Current File located at: G:/Shared drives/Work Drive/1 - Clients/2023/111 Green Bay Construction 111/GB2305_ADU_Spruce/10-Chief Architect/GB2305_ADU_Spruce.layout
PROPOSED FLOOR PLAN - Option 0041
Building Section1
Building Section2 Building Section3
PROPOSED FLOOR PLAN
:: COMMON AREA ::
KITCHEN/LI VING =213SF
:: PRIVATE AREA ::
MAN CAVE = 148SF
BATH = 58SF
BEDROOM = 125SF
:: COMMON TO PRIVATE RATIO CALCULATION ::
213SF / 532SF =40.004%
:: LIVING AREA CALC ::
PROPOSED FLOOR
PLAN
11
11
GARAGE CONVERSION
SHEET:
SCALE:
:: DRAWINGS PROVIDED BY ::
Kurt D Snyder
Green Bay Remodeling
1 9 4 9 3 7 8 3 3 5 8
1525 W MARION WAY
SANTA ANA, CA 92706
DATE:
4/9/2026
A 1 0 2
2020LS
3036LS
D06D063068
8'
4"
12'-8 1/2"
13'-0 1/2"
6'-8"
14'-10"
4"
5'3'
11
22
33
2020LS
D06D063068
3036LS
8'
4"
12'-8 1/2"
13'-0 1/2"
6'-8"
14'-10"
4"
5'3'
11
22
33
2020LS
3036LS
D06D063068
W03W03 W03W03
210683068
4040LS
2830LS
2'-8"
11 22
2'-8"
11 22W03W03 W03W03
210683068
4040LS
2830LS
W05W05W04W04
7'-0 1/2"
6'-8"13'-0 1/2"
7'-0 1/2"
6'-8"13'-0 1/2"
W05W05W04W04
D02D02 D04D04
W01W01W02W02
11
22
44
11
22
44
D02D02 D04D04
W01W01W02W02
:: ELEVATION NOTE SCHEDULE ::
(N) TRIM TO MATCH (E) WINDOWS AND
DOORS
ALL (N) FINISHED MATERIALS TO MATCH (E)
RESIDENCE IN COLOR, STYLE, ORIENTATION,
AND TEXTURE.
IMAGINARY PROPERTY LING (IPL)
WALL SURFACE = 300SF
FENESTRATION = 50SF
PERCENTAGE = 17%
11
22
33
44
11
22
33
44
210686068
4040LS 4040LS
210686068
4040LS 4040LS
WALL AREA 357SF
FENESTRATION AREA 90SF
RATIO 25.4%
WALL AREA 357SF
FENESTRATION AREA 90SF
RATIO 25.4%
REVISION TABLE
#
DATE
REVISED
BY
DESCRIPTION
1
2/22/2025
KDS
OWNER REQUEST
2
7/28/2025
KDS
INSPECTION REV
Current File located at: G:/Shared drives/Work Drive/1 - Clients/2023/111 Green Bay Construction 111/GB2305_ADU_Spruce/10-Chief Architect/GB2305_ADU_Spruce.layout
3/16" = 1'
Front Elevation1
Rear Elevation2
Left Elevations3 Right Elevations4
KEY NOTES
GENERAL NOTES
1.Dimensions are for initial building estimates
only. It is the responsibility of the Contractor
to field verify the dimensions before any
construction begins.
2.(E) GUTTER AND DOWNSPOUT TO REMAIN;
REPAIR AS NECESSARY
3.ROOF SLOPE IS 5:12 UNO
4.(N) Door and Windows are called out with
the associated tags. (E) Doors and
Windows are shown only as their (E) sizes
GENERAL NOTES
AREA OF WORK
BUILDING SECTIONS
+ ELEVATIONS
TYP. EXTERIOR FINISHASCALE: NTS
11 11
22
22
5 (E) Residence Elevation - Opposite ADU 4 - Right Elevation
GARAGE CONVERSION
SHEET:
SCALE:
:: DRAWINGS PROVIDED BY ::
Kurt D Snyder
Green Bay Remodeling
1 9 4 9 3 7 8 3 3 5 8
1525 W MARION WAY
SANTA ANA, CA 92706
DATE:
4/9/2026
A 1 0 3