Loading...
HomeMy WebLinkAbout2235 3%4 W Stanford St WCC01 - Plan2C3 SHEET #:REVISION: SHEET TITLE: REV.DATE DESCRIPTION ISSUED FOR CONSTRUCTION REVISIONS APPROVED BY: CHECKED BY: DRAWN BY: CW MEW FIN PROJECT INFORMATION: LA02330A 2235 WEST STANFORD STREET SANTA ANA, CA 92704 THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT IS STRICTLY PROHIBITED. 1200 CONCORD AVENUE CONCORD, CA 94520 PREPARED FOR: RMobileT 0 12/12/25 A&E FIRM: 1355 WINDWARD CONCOURSE, SUITE 410 ALPHARETTA, GA 30005 TEL: 678-990-2338 ISSUED FOR CONSTRUCTION101/14/26 ADDRESS JDX COMMENTS204/15/26 NO R T H NEW EQUIPMENT PLAN SCALE: 3/8" = 1'-0" EXISTING EQUIPMENT PLAN SCALE: 3/8" = 1'-0" NO R T H EXISTING & NEW EQUIPMENT PLANS NOTE: ESS IS COMPLIANT WITH CFC 1207.5.1 FOR SIZE AND SEPARATION. NOTE: THE POWER DESIGN FOR ANY AC ELECTRICAL POWER CHANGES IS TO BE PERFORMED BY OTHERS AND IS SHOWN HERE FOR REFERENCE PURPOSES ONLY. T-MOBILE IS SOLELY RESPONSIBLE FOR THE ELECTRICAL POWER DESIGN. BATTERY LOADING IN EXISTING BATTERY CABINET: ·(12) EXISTING LEAD-ACID BATTERIES = 12 * (123 lb) = 1476 lb ·(8) NEW LITHIUM-ION BATTERIES = 8 * (91 lb) = 728 lb ·THE PROPOSED LOADING IS 49% OF THE EXISTING LOADING THEREFORE THE EXISTING BATTERY CABINET IS ADEQUATE NOTES: ·REMOVE THE (12) EXISTING VALVE-REGULATED LEAD-ACID BATTERIES IN THE EXISTING B160 BATTERY CABINET. ·INSTALL (8) NEW ERICSSON 6624 LITHIUM-ION BATTERIES IN THE EXISTING B160 BATTERY CABINET. 1'-1"5" 5" 8" 8" 3' - 5 " 5' - 4 " (E) T-MOBILE RBS CABINET (E) T-MOBILE GPS ANTENNA (E) T-MOBILE RAISED EQUIPMENTS PAD (E) ALUMINUM FENCE (E) T-MOBILE CONCRETE PAD (E) MONOPOLE (E) ACCESS GATE (E) T-MOBILE CIENA BOX (TYP) (E) T-MOBILE UTILITY H-FRAME (TYP) (E) GRAVEL SURFACE AREA (E) T-MOBILE SERVICE LIGHT (E) T-MOBILE EQUIPMENT (TYP) (E) T-MOBILE EQUIPMENT (E) HANDHOLE (TYP) EXISTING T-MOBILE VALVE-REGULATED LEAD-ACID (VRLA) BATTERIES TO BE REPLACED (12 TOTAL) (E) T-MOBILE RAISED EQUIPMENT PAD 10' SETBACK FROM BATTERY CABINET (E) PARKING (TYP) (E) APPROXIMATE LOCATION OF PROPERTY LINE (TYP) (P) ERICSSON 6624 LITHIUM-ION BATTERIES (8 TOTAL) (E) TOWER FOUNDATION PAD (E) T-MOBILE DISCONNECT 1'-1"5" 5" 8" 8" 3' - 5 " 5' - 4 " (E) T-MOBILE 6160 RADIO CABINET (E) T-MOBILE B160 BATTERY CABINET(E) T-MOBILE RBS CABINET (E) T-MOBILE GPS ANTENNA (E) T-MOBILE RAISED EQUIPMENTS PAD (E) ALUMINUM FENCE (E) T-MOBILE CONCRETE PAD (E) MONOPOLE (E) ACCESS GATE (E) T-MOBILE CIENA BOX (TYP) (E) T-MOBILE UTILITY H-FRAME (TYP) (E) GRAVEL SURFACE AREA (E) T-MOBILE SERVICE LIGHT (E) T-MOBILE EQUIPMENT (TYP) (E) HANDHOLE (TYP) (E) T-MOBILE RAISED EQUIPMENT PAD 10' SETBACK FROM BATTERY CABINET (E) PARKING (TYP) (E) APPROXIMATE LOCATION OF PROPERTY LINE (TYP) (E) TOWER FOUNDATION PAD (E) T-MOBILE DISCONNECT (E) T-MOBILE 6160 RADIO CABINET (E) T-MOBILE B160 BATTERY CABINET (E) T-MOBILE EQUIPMENT 04/15/26 s<s<.J-b.J-b,,.a=,,.a=-------- 2C4 SHEET #:REVISION: SHEET TITLE: REV.DATE DESCRIPTION ISSUED FOR CONSTRUCTION REVISIONS APPROVED BY: CHECKED BY: DRAWN BY: CW MEW FIN PROJECT INFORMATION: LA02330A 2235 WEST STANFORD STREET SANTA ANA, CA 92704 THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT IS STRICTLY PROHIBITED. 1200 CONCORD AVENUE CONCORD, CA 94520 PREPARED FOR: RMobileT 0 12/12/25 A&E FIRM: 1355 WINDWARD CONCOURSE, SUITE 410 ALPHARETTA, GA 30005 TEL: 678-990-2338 ISSUED FOR CONSTRUCTION101/14/26 ADDRESS JDX COMMENTS204/15/26 BATTERY SPECS NOTES: 1.BATTERY TERMINALS - ELECTRICAL CONNECTION BETWEEN CELLS ON SEPARATE LEVELS OR RACKS SHALL NOT PUT MECHANICAL STRAIN ON THE BATTERY TERMINALS. 2.VENTS - EACH VENT CELL SHALL BE EQUIPPED WITH A FLAME ARRESTOR. 3.SEALED CELLS - WHERE A BATTERY IS CONSTRUCTED SUCH THAT EXCESSIVE ACCUMULATION OF PRESSURE COULD OCCUR WITHIN THE CELL DURING OPERATION, A PRESSURE RELIEF VENT SHALL BE PROVIDED. 4.VENTILATION - PROVISION APPROPRIATE TO THE BATTERY'S TECHNOLOGY SHALL BE MADE FOR SUFFICIENT DIFFUSION AND VENTILATION AND GASSES FROM THE BATTERY, IF PRESENT, TO PREVENT THE ACCUMULATION OF AN EXPLOSIVE MIXTURE. 04/15/26 s<s<.J-b.J-b,,.a=,,.a=-------- 2C5 SHEET #:REVISION: SHEET TITLE: REV.DATE DESCRIPTION ISSUED FOR CONSTRUCTION REVISIONS APPROVED BY: CHECKED BY: DRAWN BY: CW MEW FIN PROJECT INFORMATION: LA02330A 2235 WEST STANFORD STREET SANTA ANA, CA 92704 THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT IS STRICTLY PROHIBITED. 1200 CONCORD AVENUE CONCORD, CA 94520 PREPARED FOR: RMobileT 0 12/12/25 A&E FIRM: 1355 WINDWARD CONCOURSE, SUITE 410 ALPHARETTA, GA 30005 TEL: 678-990-2338 ISSUED FOR CONSTRUCTION101/14/26 ADDRESS JDX COMMENTS204/15/26 ESS DETAILS 04/15/26 s<s<.J-b.J-b,,.a=,,.a=-------- 2C5A SHEET #:REVISION: SHEET TITLE: REV.DATE DESCRIPTION ISSUED FOR CONSTRUCTION REVISIONS APPROVED BY: CHECKED BY: DRAWN BY: CW MEW FIN PROJECT INFORMATION: LA02330A 2235 WEST STANFORD STREET SANTA ANA, CA 92704 THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT IS STRICTLY PROHIBITED. 1200 CONCORD AVENUE CONCORD, CA 94520 PREPARED FOR: RMobileT 0 12/12/25 A&E FIRM: 1355 WINDWARD CONCOURSE, SUITE 410 ALPHARETTA, GA 30005 TEL: 678-990-2338 ISSUED FOR CONSTRUCTION101/14/26 ADDRESS JDX COMMENTS204/15/26 ESS DETAILS 04/15/26 s<s<.J-b.J-b,,.a=,,.a=-------- 2C6 SHEET #:REVISION: SHEET TITLE: REV.DATE DESCRIPTION ISSUED FOR CONSTRUCTION REVISIONS APPROVED BY: CHECKED BY: DRAWN BY: CW MEW FIN PROJECT INFORMATION: LA02330A 2235 WEST STANFORD STREET SANTA ANA, CA 92704 THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT IS STRICTLY PROHIBITED. 1200 CONCORD AVENUE CONCORD, CA 94520 PREPARED FOR: RMobileT 0 12/12/25 A&E FIRM: 1355 WINDWARD CONCOURSE, SUITE 410 ALPHARETTA, GA 30005 TEL: 678-990-2338 ISSUED FOR CONSTRUCTION101/14/26 ADDRESS JDX COMMENTS204/15/26 ESS DETAILS 6624 6624 NOTES: THE B160 IS COMPATIBLE WITH 6618 AND 6624 LITHIUM-ION BATTERIES. NO MODIFICATION TO THE CABINET REQUIRED. PARTS REQUIRED ARE EXISTING IN THE CABINET ON SITE. 04/15/26 s<s<.J-b.J-b,,.a=,,.a=-------- 2C7 SHEET #:REVISION: SHEET TITLE: REV.DATE DESCRIPTION ISSUED FOR CONSTRUCTION REVISIONS APPROVED BY: CHECKED BY: DRAWN BY: CW MEW FIN PROJECT INFORMATION: LA02330A 2235 WEST STANFORD STREET SANTA ANA, CA 92704 THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT IS STRICTLY PROHIBITED. 1200 CONCORD AVENUE CONCORD, CA 94520 PREPARED FOR: RMobileT 0 12/12/25 A&E FIRM: 1355 WINDWARD CONCOURSE, SUITE 410 ALPHARETTA, GA 30005 TEL: 678-990-2338 ISSUED FOR CONSTRUCTION101/14/26 ADDRESS JDX COMMENTS204/15/26 ESS DETAILS 6624 6624 6624 04/15/26 s<s<.J-b.J-b,,.a=,,.a=-------- 2E1 SHEET #:REVISION: SHEET TITLE: REV.DATE DESCRIPTION ISSUED FOR CONSTRUCTION REVISIONS APPROVED BY: CHECKED BY: DRAWN BY: CW MEW FIN PROJECT INFORMATION: LA02330A 2235 WEST STANFORD STREET SANTA ANA, CA 92704 THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT IS STRICTLY PROHIBITED. 1200 CONCORD AVENUE CONCORD, CA 94520 PREPARED FOR: RMobileT 0 12/12/25 A&E FIRM: 1355 WINDWARD CONCOURSE, SUITE 410 ALPHARETTA, GA 30005 TEL: 678-990-2338 ISSUED FOR CONSTRUCTION101/14/26 ADDRESS JDX COMMENTS204/15/26 (E) 1-1/2" CONDUIT (2#1 + 1#2 GND) FOR 6160 AND (1#8 + 1#10 GND) FOR B160 (E) RADIO CABINET (E) 2P 100A (E) 120/240, DISTRIBUTION PANEL (E) 2P 60A (E) 1P 20A (E) 1P 20A (E) 1P 15A (E) 120/240, 1Ø, 3W, 200A (E) PPC CABINET NEAR EQUIPMENT AREA (E) CONDUIT/ CONDUCTORS (E) SMARTMETER (E) (E) M (E) 200A, 240V POWER SOURCE (E) CONDUIT/ CONDUCTORS SU R G E P R O T E C T O R TE L C O F A N LI G H T GF I (E) BATTERY CABINET (E) RBS CABINET PANEL SCHEDULE & ONE-LINE DIAGRAM ONE-LINE DIAGRAM NOT TO SCALE PANEL SCHEDULE, TABLE 1207.1.1 & BATTERY CALCULATIONS NOT TO SCALE ESS IS LOCATED OUTDOORS ON AN EQUIPMENT PAD. ESS IS NOT LOCATED IN A HABITABLE AREA. NOTES ·DISCONNECTS (CBS) INSIDE THE B160 CABINET PER INDIVIDUAL BATTERY STRING - ALL ARE EXISTING AND TO BE RE-USED. ·ESS IS DC, NOT AC, THEREFORE IT SHOULD NOT BE INCLUDED IN THE MAINS LOAD CALCULATION. ESS/B160 IS CHARGED BY THE 6160 ALREADY IN THE LOAD TABLE. OVERVIEW OF BMS OPERATION IN BATTERY ENERGY STORAGE SYSTEMS, ONE OF THE MOST IMPORTANT HAZARD BARRIERS HELPING TO ENSURE SAFETY IS THE BATTERY MANAGEMENT SYSTEM (BMS). THE BMS PROVIDES PRIMARY THERMAL RUNAWAY PROTECTION BY ENSURING THAT THE BATTERY SYSTEM OPERATES WITHIN A SAFE RANGE OF PARAMETERS SUCH AS ITS STATE OF CHARGE AND TEMPERATURE. IN A UL 9540 LISTED BATTERY ENERGY STORAGE SYSTEM, THE BMS MONITORS, CONTROLS AND OPTIMIZES THE PERFORMANCE OF BATTERY MODULES AND DISCONNECTS THEM FROM THE SYSTEM IN THE EVENT OF ABNORMAL CONDITIONS. THE BMS ALSO PROVIDES CHARGE AND DISCHARGE MANAGEMENT OF THE BATTERIES. IN CASE OF UNDERVOLTAGE OR OVERVOLTAGE, OVER-TEMPERATURE, OR OVERCURRENT CONDITIONS, THE BMS WILL ALARM AND THEN LIMIT THE CHARGE AND DISCHARGE CURRENT OR POWER. UNDER EMERGENCY CONDITIONS, THE BMS WILL CEASE OPERATIONS AND ELECTRICALLY DISCONNECT THE BATTERY. ***NEW BATTERIES ARE TO BE INSTALLED IN THE EXISTING BATTERY CABINET. EXISTING CABINET IS NOT BEING REMOVED FOR THIS SCOPE.*** LABELING EXAMPLE ON ESS INTERNAL DISCONNECT IN ESS BATTERY CABINET IS LOCATED ON AN OUTDOOR PAD AND IS IN COMPLIANCE WITH CEC 703.1(6) DC ONE-LINE DIAGRAM NOTE: THE SECOND 300A BREAKER CONNECTION BETWEEN E6160AC AND B160 SHOULD BE INSTALLED. THIS IS TO PREVENT BATTERY BREAKERS FROM TRIPPING DURING A COLD START SCENARIO WHERE INITIAL CURRENT DRAW MAY TRIP THE BATTERY BREAKER AND REQUIRE FIELD VISIT TO RESET BREAKER. 04/15/26 s<s<.J-b.J-b,,.a=,,.a=-------- 2G1 SHEET #:REVISION: SHEET TITLE: REV.DATE DESCRIPTION ISSUED FOR CONSTRUCTION REVISIONS APPROVED BY: CHECKED BY: DRAWN BY: CW MEW FIN PROJECT INFORMATION: LA02330A 2235 WEST STANFORD STREET SANTA ANA, CA 92704 THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT IS STRICTLY PROHIBITED. 1200 CONCORD AVENUE CONCORD, CA 94520 PREPARED FOR: RMobileT 0 12/12/25 A&E FIRM: 1355 WINDWARD CONCOURSE, SUITE 410 ALPHARETTA, GA 30005 TEL: 678-990-2338 ISSUED FOR CONSTRUCTION101/14/26 ADDRESS JDX COMMENTS204/15/26 WIRE SIZE BURNDY LUG TYPE HS TYPE 2-YA-2 TYPE XA TYPE YA-2 TYPE GY #6 AWG GREEN INSULATED #2 AWG SOLID TINNED #2 AWG STRANDED #2/0 AWG STRANDED #4/0 AWG STRANDED TYPE VV TYPE VN TYPE NC TYPE SS TYPE GR YA6C-2TC38 YA3C-2TC38 YA2C-2TC38 YA26-2TC38 YA28-2N BURNDY GROUND LUG W/ LONG BARREL (SEE CHART) NUT (TYP) LOCK WASHER (TYP) TYPE VS BURNDY TWO HOLE LUG W/ LONG BARREL (SEE CHART) BARE WIRE TO BE NO-OX AT BOTH ENDS STRANDED (GREEN INSULATED) ONLY FOR #6 AWG (SEE CHART) TYPE VB TYPE PT TYPE GT² BOLT SIZE 1/2" - 16 NC S 2 BOLT 3/8" - 16 NC S 2 BOLT 3/8" - 16 NC S 2 BOLT 3/8" - 16 NC S 2 BOLT 3/8" - 16 NC S 2 BOLT HEAT SHRINK (CLEAR) GROUNDING CONDUCTOR GROUND BAR BOLT (SEE CHART) (TYP) STAINLESS STEEL BOLT (TYP) 2-HOLE CRIMP/ COMPRESSION CONNECTOR STAINLESS STEEL FLAT WASHER (TYP) GROUND BAR STAINLESS STEEL BELLVILLE WASHER (TYP) STAINLESS STEEL FLAT WASHER (TYP) STAINLESS STEEL NUT (TYP) STAINLESS STEEL BOLT STAINLESS STEEL FLAT WASHER DRAGON TOOTH WASHER (TYP) STEEL 3/8-11x1" TAMPER RESISTANT BOLT (TYP) INSULATORS SEE NOTE 2. (TYP) WALL BRACKET (TYP) 2-HOLE CRIMP/ COMPRESSION CONNECTOR STAINLESS STEEL BELLVILLE WASHER (TYP) STAINLESS STEEL FLAT WASHER (TYP) STAINLESS STEEL NUT (TYP) STAINLESS STEEL SELF-DRILLING METAL SCREW (TYP) UNIVERSAL COPPER GROUND BAR (4"x20") LOCK WASHER P/N M10 (TYP) TW0-HOLE COMPRESSION LUG 2-HOLE CRIMP/ COMPRESSION CONNECTOR DRAGON TOOTH WASHER (TYP) METALLIC OBJECT STAINLESS STEEL FLAT WASHER (TYP) NOTE: MINIMUM OF 3 THREADS TO BE VISIBLE (TYP) 2 HOLE LONG BARREL TINNED SOLID COPPER LUG (TYP) S/S NUT (TYP) S/S SPLIT WASHER (TYP) S/S FLAT WASHER (TYP) TIN COATED SOLID COPPER BUS BAR CHERRY INSULATOR INSTALLED IF REQUIRED S/S FLAT WASHER (TYP) S/S BOLT (TYP) NOTE: 1. ERICO EXOTHERMIC "MOLD TYPES" SHOWN HERE ARE EXAMPLES. CONSULT WITH CONSTRUCTION MANAGER FOR SPECIFIC MOLDS TO BE USED FOR THIS PROJECT. 2. MOLD TYPE ONLY TO BE USED BELOW GRADE WHEN CONNECTING GROUND RING TO GROUND ROD. CADWELD GROUNDING CONNECTIONS NOT TO SCALE SIGNAGE NOT TO SCALE NOTES: 1. ALL GROUNDING LUGS ARE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. ALL HARDWARE BOLTS, NUTS, LOCK WASHERS SHALL BE STAINLESS STEEL. ALL HARDWARE ARE TO BE AS FOLLOWS: BOLT, FLAT WASHER,GROUND BAR, GROUND LUG, FLAT WASHER AND NUT. MECHANICAL LUG CONNECTION NOT TO SCALE LUG DETAIL NOT TO SCALE SINGLE CONNECTOR AT METALLIC/STEEL OBJECTS SINGLE CONNECTOR AT STEEL OBJECTS SINGLE CONNECTOR AT GROUND BARS HARDWARE DETAIL (EXTERIOR CONNECTIONS) NOT TO SCALE NOTES: 1. DOWN LEAD (HOME RUN) CONDUCTORS ARE NOT TO BE INSTALLED ON CROWN CASTLE USA INC. TOWER, PER THE GROUNDING DOWN CONDUCTOR POLICY QAS-STD-10091. NO MODIFICATION OR DRILLING TO TOWER STEEL IS ALLOWED IN ANY FORM OR FASHION, CAD-WELDING ON THE TOWER AND/OR IN THE AIR IS NOT PERMITTED. 2. OMIT INSULATOR WHEN MOUNTING TO TOWER STEEL OR PLATFORM STEEL USE INSULATORS WHEN ATTACHING TO BUILDINGS OR SHELTERS. GROUND BAR DETAIL NOT TO SCALE GROUNDING DETAILS 04/15/26 s<s<.J-b.J-b,,.a=,,.a=--------