HomeMy WebLinkAbout2071 & 2069 S Evergreen St - REV 1 - PlanREF 10'-0" CLG HT. (N) BEDROOM #1 (152 SQ. FT.) 10'-0" CLG HT. (N) BEDROOM #2 (122 SQ. FT.) (N) BATHROOM (N) CLOSET (N) CLOSET (N) LIVING AREA (N) KITCHEN N (N) ADU FLOOR PLAN W/D 10'-0" CLG HT. 10'-0" CLG HT. TVAFCI TV AF C I TV AF C I WP GFCI EXTERIOR HOSE-BIB EXTERIOR HOSE-BIB 1 2 6 2 3 5 B D AA C 7' - 1 0 " x 3 ' - 0 " CO N C R E T E L A N D I N G 22"x30"ATTIC ACCESS 10 0 A M P SU B - P A N E L TA N K L E S S WA T E R H E A T E R WP G F C I TANKLESS WATER HEATER WILL BE ENCLOSED & PAINTED TO MATCH STRUCTURE CONDENSERCENTRAL (N) WINDOW SCHEDULE SYMBOLS A DESCRIPTIONSIZE B 3'-0"x3'-0" 6'-0"x4'-0" C 2'-8"x1'-4" (N) DOOR SCHEDULE SYMBOLS 1 DESCRIPTIONSIZE 5'-0"x6'-8"EXTERIOR SOLID CORE DOUBLE DOORS VINYL SLIDER (LOW E) 2 VINYL SLIDER (LOW E) VINYL SLIDER (LOW E) U-FACTOR SHGC 0.32 0.25 0.32 0.25 0.32 0.25 TEMPERED GLAZED NOTES: TEMPERED GLAZED TEMPERED GLAZED 2'-8"x6'-8"INTERIOR HOLLOW DOOR 3 7'-0"x6'-8"CLOSET MIRRORED INTERIOR SLIDER DOORS N N) ADU ROOF PLAN 4:12 4:12 4: 1 2 4: 1 2 4 5'-0"x6'-8"EXTERIOR GLASS SLIDER DOOR D 5'-0"x3'-0"VINYL SLIDER (LOW E)0.32 0.25 TEMPERED GLAZED E 3'-0"x4'-0"VINYL SLIDER (LOW E)0.32 0.25 TEMPERED GLAZED EAVE EAVE EAVE EAVEEAVE EAVE EAVE EAVE FR A2.2 ROOF VENT SHOWER SHALL MAINTAIN A MINIMUM FINISH INTERIOR OF 1024 SQ. IN. AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30" CIRCLE. FLOOR PLAN KEY NOTES DOOR LANDING MINIMUM 36" DEEP x WIDTH OF DOOR. A DOOR MAY SWING OVER LANDING THAT IS NOT MORE THAN 1-1/2" BELOW THE THRESHOLD. (CRC R311.3) FLOOR ELEVATION AT THE REQUIRED EGRESS WITH 1-1/2" OF THRESHOLD. EXCEPTION: AT DOORS OTHER THAN THE MAIN EGRESS DOOR, THE EXTERIOR LANDING OR FLOOR SHALL NOT BE MORE THAN 7-3/4" BELOW THE TOP OF THE THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR. A MINIMUM RATE OF 725 CFM IS REQUIRED FOR THE KITCHEN EXHAUST VENTILATION. MIN 4" DUCT SIZE SHALL MEET THE MINIMUM REQUIREMENTS OF ASHRA STANDARD 62.2 AND MAXIMUM SOUND RATING OR 3 SONE FOR INTERMITTENT OPERATION (KITCHEN SHALL BE VENTED TO THE OUTSIDE) A/C CENTRAL CONDENSER (HEAT PUMP) BATHTUB & SHOWER FLOORS & WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS & IN SHOWER COMPARTMENTS SHALL BATHROOM & SHOWER NOTES: a.BATHTUB & SHOWER FLOORS & WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS & IN SHOWER COMPARTMENTS SHALL BE FINISHED WITH NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR. CRC R307.2 b. GYPSUM BOARD SHALL NOT BE USED WHERE THERE WILL BE DIRECT EXPOSURE TO WATER, OR IN AREAS SUBJECT TO CONTINUOUS HIGH HUMIDITY. CRC R702.3.8.1 5 9'-0"x6'-8"CLOSET MIRRORED INTERIOR SLIDER DOORS 6 2'-8"x6'-8"POCKET SLIDER DOOR 7 3'-0"x6'-8"EXTERIOR SOLID CORE DOOR 7 3' - 0 " x 4 ' - 0 " LA N D I N G HEAT PUMP FR A2.2 DETAIL DRAWING No. A2.2 SC O P E O F W O R K : DA T E : 1 2 3 RE V I S I O N S : SI T E A D D R E S S : DR A W I N G NA M E : (N ) D E T A C H E D A D U F L O O R P L A N OW N E R ' S N A M E DR A W N B Y : AR K D I S T R I C T D E S I G N S E- M A I L : A R K D I S T R I C T D E S I G N S @ G M A I L . C O M PH : ( 3 2 3 ) 3 0 4 - 5 5 8 1 71 7 1 W A R N E R A V E . S U I T E B # 1 0 5 HU N T I N G T O N B E A C H , C A . 9 2 6 4 7 VI C E N T E M A R Q U E Z (9 4 9 ) 5 6 6 - 7 1 3 1 PRJ.No.:242603 20 6 9 - 2 0 7 1 S . E V E R G R E E N S T . SA N T A A N A , C A 9 2 7 0 7 (N ) D E T A C H E D A D U & R E A R P A T I O L E G A L I Z A T I O N FLOOR PLAN NOTES: 1. Electrical receptacle outlets, switches, and controls (including controls for heating, ventilation and air conditioning) intended to be used by occupants shall be located no more than 48” measured from the top of the outlet box and not less than 15” measured from the bottom of the outlet box above the finish floor. [CRC R327.1.2] Exceptions: b) Receptacle outlets required by the California Electrical Code on a wall space where the distance between the finished a) Dedicated receptacle outlets; floor receptacle outlets; controls mounted on ceiling fans and ceiling lights; and controls located on appliances. floor and a built-in feature above the finish floor, such as a window, is less than 15 inches (381 mm). 2. Effective July 1, 2024, at least one bathroom and one bedroom on the entry level shall provide a doorway with a net clear opening of not less than 32 inches, measured with the door positioned at an angle of 90 degrees from the closed position; or, in the case of a two- or three-story singlefamily dwelling, on the second or third floor of the dwelling if a bathroom or bedroom is not located on the entry level. [CRC R327.1.3] 3. Doorbell buttons or controls, when installed, shall not the top of the doorbell button assembly. Where doorbell buttons integrated with other features are required to be installed above 48 inches measured from the exterior floor or landing, a standard doorbell button or control shall also be provided at a height not exceeding 48 inches above exterior floor or landing, measured from the top of the doorbell button or control. [CRC R327.1.4] 3. Doorbell buttons or controls, when installed, shall not exceed 48 inches above exterior floor or landing, measured from ADA NOTES: (N) STUCCO TO MATCH PRIMARY(N) STUCCO TO MATCH PRIMARY (N) STUCCO TO MATCH PRIMARY (N) STUCCO TO MATCH PRIMARY ELECTRIC. SUBPANEL TANKLESS WATER HEATER A/C CENTRALCONDENSER NORTH ELEVATIONSOUTH ELEVATION FINISHED GRADE FINISHED GRADE WEST ELEVATIONEAST ELEVATION AWNING AWNING RECESS BOX(PAINTABLE & LOCKABLE) SOUTH ELEVATION EAST ELEVATIONSECTION B FINISHED GRADE SECTION A DRAWING No. A3.2 SC O P E O F W O R K : DA T E : 1 2 3 RE V I S I O N S : SI T E A D D R E S S : DR A W I N G NA M E : NE W D E T A C H E D A D U E L E V A T I O N S OW N E R ' S N A M E DR A W N B Y : AR K D I S T R I C T D E S I G N S E- M A I L : A R K D I S T R I C T D E S I G N S @ G M A I L . C O M PH : ( 3 2 3 ) 3 0 4 - 5 5 8 1 71 7 1 W A R N E R A V E . S U I T E B # 1 0 5 HU N T I N G T O N B E A C H , C A . 9 2 6 4 7 VI C E N T E M A R Q U E Z (9 4 9 ) 5 6 6 - 7 1 3 1 PRJ.No.:242603 20 6 9 - 2 0 7 1 S . E V E R G R E E N S T . SA N T A A N A , C A 9 2 7 0 7 (N ) D E T A C H E D A D U & R E A R P A T I O L E G A L I Z A T I O N FOUNDATION PLAN - (ADU) scale: 1/4"=1'-0" PLAN NOTES LEGEND GENERAL CONTRACTOR NOTES CONTRACTOR IS RESPONSIBLE TO VERIFY ALL THE EXISTING CONDITION AND SHALL NOTIFY THE ENGINEER OF RECORD IF ANY DISCREPANCIES FOUND. NOTES:R E V I S I O N REVISIONSMARKDATE SHEET OF 11 TITLE CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. JOB #:DRAWN: DATE:CHECKED: 24-351 L.R.* E.C. / M.C.Mar. 13, 26 1 2 3 OW N E R : VI C E N T E M A R Q U E Z AD D R E S S : 20 7 1 S E V E R G R E E N S T . , SA N T A A N A , C A 9 2 7 0 7 MA R Q U E Z R E S I D E N C E NE W D E T A C H E D A D U & NE W A T T A C H E D P A T I O CO V E R PR O J E C T A D D R E S S : 20 7 1 S E V E R G R E E N S T . , SA N T A A N A , C A 9 2 7 0 7 AL ENGINE R RNIA E OF ESSI C77737G ISTERED CIV IL R STAT E PR ON O EXP. 6-30-27 E OF CALIF SIGNED: 3/13/26 AL ENGINE R RNIA E OF ESSI C77737G ISTERED CIV IL R STAT E PR ON OEOFCALIF SIGNED: 3/13/26 AL ENGINE R RNIA E OF ESSI C77737G ISTERED CIV IL R STAT E PR ON OEOFCALIF SIGNED: 3/13/26 14 1 2 E S P A N O L A V E . , MO N T E B E L L O , C A 9 0 6 4 0 WW W . E C A E N G I N E E R I N G . C O M IN F O @ E C A E N G I N E E R I N G . C O M P: 5 6 2 7 0 8 3 5 8 6 PC106-07-2025 REV107-31-2025 REV203-13-2026 S2.0 FOUNDATION PLAN (ADU) 6 ROOF FRAMING PLAN - (ADU) scale: 1/4"=1'-0" PLAN NOTES LEGEND GENERAL CONTRACTOR NOTES ADDITIONAL NOTES CONTRACTOR IS RESPONSIBLE TO VERIFY ALL THE EXISTING CONDITION AND SHALL NOTIFY THE ENGINEER OF RECORD IF ANY DISCREPANCIES FOUND. NOTES:R E V I S I O N REVISIONSMARKDATE SHEET OF 11 TITLE CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. JOB #:DRAWN: DATE:CHECKED: 24-351 L.R.* E.C. / M.C.Mar. 13, 26 1 2 3 OW N E R : VI C E N T E M A R Q U E Z AD D R E S S : 20 7 1 S E V E R G R E E N S T . , SA N T A A N A , C A 9 2 7 0 7 MA R Q U E Z R E S I D E N C E NE W D E T A C H E D A D U & NE W A T T A C H E D P A T I O CO V E R PR O J E C T A D D R E S S : 20 7 1 S E V E R G R E E N S T . , SA N T A A N A , C A 9 2 7 0 7 AL ENGINE R RNIA E OF ESSI C77737G ISTERED CIV IL R STAT E PR ON O EXP. 6-30-27 E OF CALIF SIGNED: 3/13/26 AL ENGINE R RNIA E OF ESSI C77737G ISTERED CIV IL R STAT E PR ON OEOFCALIF SIGNED: 3/13/26 AL ENGINE R RNIA E OF ESSI C77737G ISTERED CIV IL R STAT E PR ON OEOFCALIF SIGNED: 3/13/26 14 1 2 E S P A N O L A V E . , MO N T E B E L L O , C A 9 0 6 4 0 WW W . E C A E N G I N E E R I N G . C O M IN F O @ E C A E N G I N E E R I N G . C O M P: 5 6 2 7 0 8 3 5 8 6 PC106-07-2025 REV107-31-2025 REV203-13-2026 S2.1 ROOF FRMG. PLAN (ADU) 7 DRAWING No. T24.1 TI T L E 2 4 E N E R G Y C A L C S . SI T E A D D R E S S : DR A W I N G NA M E : 20 7 1 S . E V E R G R E E N S T . SA N T A A N A , C A . 9 2 7 0 7 DRAWING No. T24.2 TI T L E 2 4 E N E R G Y C A L C S . SI T E A D D R E S S : DR A W I N G NA M E : 20 7 1 S . E V E R G R E E N S T . SA N T A A N A , C A . 9 2 7 0 7 DRAWING No. T24.3 TI T L E 2 4 E N E R G Y C A L C S . SI T E A D D R E S S : DR A W I N G NA M E : 20 7 1 S . E V E R G R E E N S T . SA N T A A N A , C A . 9 2 7 0 7 Exhaust Fan 5 Change/Hr. Min. 50 CFM Capacity W Humidistat - Direct Vent, Energy Star Outlet w/ Ground Fault InterruptorGFCI AFCI Outlet w/ Arc Fault Interruptor Smoke Detector Hard Wired w/Battery Back-Up and Alarms interconnectedSD State Fire Marshall-Approved UL 2034/2075 Carbon Monoxide Alarm Hard Wired w/Battery Back-Up and Alarms interconnected Water Proof Outlet w/ Ground Fault InterruptorWP GFCI N (N) ADU ELECTRICAL FLOOR PLAN TVAFCI TV AF C I TV AF C I AFCIAFCIAFCIAFCI AFCI AF C I AF C I AF C I AF C I AF C I AF C I GFCI GFCI GFCI GFCIGFCI GFCI GFCI SD SD SD WP G F C I 10 0 A M P SU B - P A N E L EXTERIOR HOSE-BIB EXTERIOR HOSE-BIB WP GFCI 7' - 1 0 " x 3 ' - 0 " CO N C R E T E L A N D I N G WP G F C I WP G F C I EXTERIOR DOWN-LIGHT FIXTURE EXTERIOR DOWN-LIGHT FIXTURE EXTERIOR DOWN-LIGHT FIXTURE EXTERIOR DOWN-LIGHT FIXTURE EXTERIOR LIGHT FIXTURE EXTERIOR LIGHT FIXTURE EXTERIOR LIGHT FIXTURE EXTERIOR LIGHT FIXTURE EXTERIOR LIGHT FIXTURE 22"x30"ATTIC ACCESS WP GFCI TA N K L E S S WA T E R H E A T E R WP G F C I REFW/D CONDENSERCENTRAL HEAT PUMP DRAWING No. E1 SC O P E O F W O R K : DA T E : 1 2 3 RE V I S I O N S : SI T E A D D R E S S : DR A W I N G NA M E : NE W D E T A C H E D A D U E L E C T R I C A L F L O O R P L A N OW N E R ' S N A M E DR A W N B Y : AR K D I S T R I C T D E S I G N S E- M A I L : A R K D I S T R I C T D E S I G N S @ G M A I L . C O M PH : ( 3 2 3 ) 3 0 4 - 5 5 8 1 71 7 1 W A R N E R A V E . S U I T E B # 1 0 5 HU N T I N G T O N B E A C H , C A . 9 2 6 4 7 VI C E N T E M A R Q U E Z (9 4 9 ) 5 6 6 - 7 1 3 1 PRJ.No.:242603 20 6 9 - 2 0 7 1 S . E V E R G R E E N S T . SA N T A A N A , C A 9 2 7 0 7 (N ) D E T A C H E D A D U & R E A R P A T I O L E G A L I Z A T I O N “ “ ELECTRIC READY NOTES: N (N) ADU PLUMBING PLAN 10 0 A M P SU B - P A N E L (E ) 3/ 4 " W A T E R S U P P L Y L I N E T O A D U TA N K L E S S WA T E R H E A T E R N (N) ADU SEWER/WASTE PLAN 10 0 A M P SU B - P A N E L TA N K L E S S WA T E R H E A T E R CONNECT TO 2" ABS VENT AND PROVIDE CLEAN OUT WITH 2" ABS DRAIN AT 2% SLOPE POINT OF CONNECTION TO NEW MAIN INCOMING 3/4" WATER LINE VERIFY ON FIELD PLUMBING PLAN KEY NOTES CONNECT 3" ABS DRAIN LINE AT 2% SLOPE TO MEET AT POINT OF CONNECTION POINT OF CONNECTION TO BE VERIFIED ON FIELD WITH SEWER LOCATION CAMERA INSPECTION 1/2" WATER LINES CONNECTION PROVIDE ANGLE STOPS WITH ESCUTCHEON NEW HOSE BIBB SHALL BE PROVIDE WITH AN APPROVED ANTI-SIPHON DEVICE PLUMBING FIXTURES (WATER CLOSETS AND URINALS) AND FITTINGS (SHOWERHEADS, FAUCETS, AND PRE-RINSE SPRAY VALVES) INSTALLED IN RESIDENTIAL BUILDINGS SHALL COMPLY WITH REQUIREMENTS OF CALGREEN SECTIONS 4.303.1.1 THROUGH 4.303.1.4.5 AND CPC 411.2, 412.1, 417.1, 420.2: PLUMBING FIXTURES & FITTINGS MAXIMUM WATER CLOSETS 1.28 GALLONS/FLUSH SHOWERHEADS 1.8 GPM @ 80 PSI KITCHEN FAUCETS 1.8 GPM @ 60 PSI RESIDENTIAL LAVATORY FAUCETS 1.2 GPM @ 60 PSI MAX. 0.8 GPM @ 20 PSI MIN. LAVATORY FAUCETS IN COMMON & PUBLIC USE AREAS 0.5 GPM @ 60 PSI METERING FAUCETS 0.20 GALLONS/CYCLE URINALS 0.125 GALLONS/FLUSH FOR WALL-MOUNTED TYPE AND 0.5 GALLONS/FLUSH FOR FLOOR-MOUNTED TYPE OR OTHER TYPE PRE-RINSE SPRAY VALVES (WITH AN INTEGRAL AUTOMATIC SHUTOFF) 1.0 GPM FOR PRODUCT CLASS 1 (≤ 5.0 OZF) 1.20 GPM FOR PRODUCT CLASS 2 (> 5.0 OZF AND ≤ 8.0 OZF) 1.28 GPM FOR PRODUCT CLASS 3 (> 8.0 OZF) PLASTICS MATERIALS FOR BUILDING SUPPLY PIPING OUTSIDE UNDERGROUND SHALL HAVE AN ELECTRICALLY CONTINUOUS-CORROSION RESISTANT BLUE INSULATED 14 AWG MIN. COPPER TRACER WIRE. ACCESS SHALL BE PROVIDED TO THE TRACER WIRE, OR THE TRACER WIRE SHALL TERMINATE ABOVE GROUND AT EACH END OF THE NONMETALLIC PIPING. [CPC 604.10.1] “BECAUSE OF THE CITY'S PROXIMITY TO THE SAN ANDREAS FAULT, ALL UNDERGROUND PIPE, CONDUIT, AND LINES WILL BE SHADED WITH CLEANED DIRT VOID OF ANY ROCKS OR CLEAN SAND, 6” BELOW AND 12” ABOVE SAID PIPE, CONDUIT, OR LINE. ALL ELECTRICAL METAL CONDUIT WILL NEED A GROUND CONDUCTOR, THE METAL CONDUIT WILL NOT ACT AS THE GROUND CONDUCTOR [PER CITY ORDINANCE]”. PLUMBING NOTES: W/D W/DREFREF DRAWING No. P1 SC O P E O F W O R K : DA T E : 1 2 3 RE V I S I O N S : SI T E A D D R E S S : DR A W I N G NA M E : NE W D E T A C H E D A D U P L U M B I N G & S E W E R / W A S T E P L A N OW N E R ' S N A M E DR A W N B Y : AR K D I S T R I C T D E S I G N S E- M A I L : A R K D I S T R I C T D E S I G N S @ G M A I L . C O M PH : ( 3 2 3 ) 3 0 4 - 5 5 8 1 71 7 1 W A R N E R A V E . S U I T E B # 1 0 5 HU N T I N G T O N B E A C H , C A . 9 2 6 4 7 VI C E N T E M A R Q U E Z (9 4 9 ) 5 6 6 - 7 1 3 1 PRJ.No.:242603 20 6 9 - 2 0 7 1 S . E V E R G R E E N S T . SA N T A A N A , C A 9 2 7 0 7 (N ) D E T A C H E D A D U & R E A R P A T I O L E G A L I Z A T I O N