HomeMy WebLinkAbout128 W MacArthur Blvd - PlanSHEET INDEX
THE NOODLE LOFT
128 W MACARTHUR BLVD
SANTA ANA, CA 92707
• DEMOLITION OF THE EXISTING NON-BEARING WALLS OF THE PREVIOUS TENANT SPACE.
• NEW ELECTRICAL WIRING FOR COMMERCIAL KITCHEN AND OPEN DINING SPACES. INSTALLATION
WORK TO BE COMPLETED BY A LICENSED ELECTRICIAN. NEW ROUTING AND DUCTING TO BE
CONNECTED TO THE EXISTING MECHANICAL UNIT. NEW PLUMBING FIXTURES AND
UNDERGROUND PIPING TO BE INSTALLED.
• UPGRADE TO RESTROOM TO MEET ACCESSIBILITY CODE COMPLIANCE.
• INSTALLATION OF NEW VENTED HOOD AND MAKE-UP AIR SYSTEM.
A. P. N.:
ADDRESS:
ZONING:
TYPE OF CONSTRUCTION:
OCCUPANCY:
BUILDING AREA S.F.
PROPOSED S.F.:
SPRINKLERED:
SCOPE OF WORK
PROJECT INFORMATION
K1
K1
ROOM
NAME
101
A2.32
1
1
1
1 ELEVATION
ALIGN
DIMENSION CENTERLINE
DIMENSION
REVISION CLOUD
KEY NOTE
COLUMN GRID LINE
ROOM REFERENCE
SECTION
REFERENCE
ELEVATION
REFERENCE
DETAIL OR ENLARGED PLAN
DATUM
7' - 6"
7' - 6"
CL
SHEET NUMBER
VIEW NUMBER
VIEW NAME
DRAWING SCALE
VIEW NUMBER
NORTH ARROW
(PROJECT NORTH U.O.N.)
101
LEGEND AND SYMBOLS
VICINITY MAP
APPLICABLE CODE
DEFERRED SUBMITTAL
3' - 9"3' - 9"
AUTHORITY HAVING JURISDICTION : CITY OF SANTA ANA
ALL WORK SHALL COMPLY WITH THE FOLLOWING CODES:
• CITY OF SANTA ANA MUNICIPAL CODE
• ORANGE COUNTY ENVIRONMENTAL HEALTH DEPARTMENT
• 2025 CALIFORNIA BUILDING CODE
• 2025 CALIFORNIA ELECTRICAL CODE
• 2025 CALIFORNIA PLUMBING CODE
• 2025 CALIFORNIA MECHANICAL CODE
• 2025 CALIFORNIA GREEN BUILDING STANDARDS CODE
• 2025 CALIFORNIA ENERGY CODE
• 2025 CALIFORNIA FIRE CODE
SITE FACILITY MAP
PROJECT TEAM
KEY NOTE
A-?
?
DETAIL SECTION
REFERENCEA-?
?
A-?
1
410-041-51
128 W MACARTHUR BLVD, SANTA ANA, CA 92707
C4 - COMMERCIAL PLANNED SHOPPING CENTER
TYPE V-B
GROUP B
1,240 SQUARE FOOT
N/A
NO
PROJECT SITE
• ANSUL FIRE SUPPRESSION SYSTEM
OWNER: LEGACY THAI GROUP
CONTACT: SUKITTI KEERATIPRAPA
E-MAIL: LEGACYTHAIGROUP@GMAIL.COM
TEL: (949) 836-1777
ARCHITECT OF RECORD : SANDPIPER ARCHITECTURE
CONTACT: SAMUEL PIPER
E-MAIL: SANDPIPERARCHITECT@GMAIL.COM
TEL: (707) 815-6742
ENGINEER OF RECORD: ERIC CHEN
CONTACT: ERIC CHEN
E-MAIL: HSINGYUERIC@GMAIL.COM
TEL: (626) 423-8463
55
73
405
S
B
R
I
S
T
O
L
S
T
MACARTHUR BLVD
MA
I
N
S
T
BE
A
R
S
T
PROJECT LOCATION
BAKER ST JOHN
WAYNE
AIRPORT
RED HILL AVE
E DYER RD
A.F.F.ABOVE FINISHED FLOOR
A.G.ACCESSORY GROUP
A.D.ACCESS DOOR
ACOUS ACOUSTICAL
ACT.ACOUSTICAL TILE
ADD ADDENDUM
ADJ ADJACENT
A.C.AIR CONDITION
ALT ALTERNATE
ALUM ALUMINUM
A.B.ANCHOR BOLT
APPROX APPROXIMATE
ARCH ARCHITECTURAL
AD AREA DRAIN
AUTO AUTOMATIC
ASL ABOVE SEA LEVEL
B.E.J.BRICK EXPANSION JOINT
BSMT BASEMENT
B.T.BATH TUB
BM BEAM
BRG BEARING
B.M.BENCH MARK
BET BETWEEN
BIT BITUMINOUS
BLK BLOCK
BLKG BLOCKING
BD BOARD
BS BOTH SIDES
BOT BOTTOM
BRK BRICK
B.C.BRICK COURSE
BLDG BUILDING
BUR BUILT-UP ROOFING
B.O.BY OWNER
CAB CABINET
C.H. CABINET HEATER
CHNL CHANNEL
C.O.CLEAN OUT
CO2 CARBON DIOXIDE
CARP.CARPET
C.W.CASEWORK
C.I.CAST IRON
C.B.CATCH BASIN
CEM CEMENT
CM CENTIMETER
CT CERAMIC TILE
CHBD CHALK BOARD
CLG. CEILING
CLR CLEAR
COL COLUMN
CONC.CONCRETE
CMU CONCRETE MASONRY UNIT
COND CONDUCTIVE
C.S.V CONDUCTIVE SHEET VINYL
CONT.CONTINUOUS
CLL CONTRACT LIMIT LINE
CONTR CONTRACTOR
C.J.CONTROL JOINT
CONV CONVECTOR
C.G.CORNER GUARD
CORR CORRIDOR
C.S.COUNTER SINK
CRS COURSE
C.R.CURTAIN ROD
C.R.-1 CRASH RAIL
DEM DEMOLISH/DEMOLITION
DET.DETAIL
DIAG DIAGONAL
DIA. DIAMETER
DIFF. DIFFUSER
DIM. DIMENSION
DISP.DISPENSER
DO DITTO
DR DOOR
DBL DOUBLE
DN DOWN
DS DOWNSPOUT
DWG.DRAWING
D.F.DRINKING FOUNTAIN
EA EACH
ELEC.ELECTRICAL
ELEC. CAB ELECTRIC CABINET
EPNL ELECTRIC PANEL
EWC ELECTRIC WATER COOLER
EL ELEVATION
ELEV. ELEVATOR
EQ EQUAL
E.O.EQUIPMENT BY OWNER
EX EQUIPMENT, X-RAY
EX.F EXHAUST FAN
(E)EXISTING
EXP. JT.EXPANSION JOINT
EXP'D EXPOSED
EXT EXTERIOR
E.I.F.S.EXTERIOR INSULATION
& FINISH SYSTEM
FB FACE BRICK
F.C.U.FAN COIL UNIT
F.D.C.FIRE DEPARTMENT
CONNECTIONS
F.N.V.FEM. NAPKIN VENDOR
FIN.RAD.FIN TUBE RADIATION
FIN FINISH
F.A.FIRE ALARM
FEC FIRE EXTINGUISHER CAB
FHC FIRE HOSE CABINET
F.H.FIRE HYDRANT
F.P.FIRE PROOFING
FHMS FLAT HEAD MACH.SCREW
FHWS FLAT HEAD WOOD SCREW
FL. FLOOR
F.D.FLOOR DRAIN
FR FRAME
F.S. FINISH SLAB
FT FOOT
FTG FOOTING
FDTN FOUNDATION
FUR FURRING
FUR. CH.FURRING CHANNEL/S
F.W.FULL WIDTH
F.W.C.FABRIC WALL COVERING
GAL GALLON
GALV.GALVANIZED
GI GALVANIZED IRON
GA GAGE
G.C.GENERAL CONTRACT
GL GLASS
G.B.GRAB BAR
GSF GROSS SQUARE FEET
G.W.B.GYPSUM WALL BOARD
HR-1 HANDRAIL
HDNR HARDENER
HDW HARDWARE
HD.WD.HARDWOOD
HTR HEATER
HTG HEATING
HVAC HEATING, VENTILATION
& AIR CONDITIONING
HT HEIGHT
HC HOLLOW CORE
HM HOLLOW METAL
HORIZ HORIZONTAL
HB HOSE BIB
H.C.HOSE CABINET
H.C.U.HOSPITAL CASEWORK UNIT
H.C.T.HOSPITAL CUBICAL TRACK
H.PL. HOT PLATE
H.P.L.HIGH PRESSURE
PLASTIC LAMINATE
H.W.HOT WATER
HR HOUR
INCIN.INCINERATOR
I.D.INSIDE DIAMETER
INSUL. INSULATE(D)(ION)
INS. GL INSULATED GLASS
INT INTERIOR
IV INTRAVENOUS
INV INVERT
JAN JANITOR
JT JOINT
KIT KITCHEN
KO KNOCK OUT
L.C.LABORATORY CASEWORK
LEV LOW EMISSION VEHICLE
LAM LAMINATED
LAV.LAVATORY
L.GL.LEADED GLASS
LH LEFT HAND
LGT LENGTH
LT LIGHT
LT.P LIGHT PANEL
LTWT LIGHT WEIGHT
L.F.LINEAR FEET
LTL LINTEL
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LVR LOUVER
L.P.LOW POINT
MACH MACHINE
M.H.MANHOLE
MFR MANUFACTURER
MARB MARBLE
MAS MASONRY
M.O.MASONRY OPENING
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MC MEDICINE CABINET
MEMB MEMBRANE
MET METAL
MTD MOUNTED
M.T.P.METAL TOILET PARTITION
MET. TM METAL TRIM
M.W.U.MILLWORK UNIT
MIN. MINIMUM
MISC.MISCELLANEOUS
MOD MODULAR
M.H.MOP HOPPER
MOV MOVABLE
MULL MULLION
(N)NEW
NAT NATURAL
N.L. NIGHT LIGHT
N2O NITROUS OXIDE
NRC NOISE REDUCTION COEIF.
N.I.C. NOT IN CONTRACT
N.T.S.NOT TO SCALE
NOM NOMINAL
NO. NUMBER
OBS OBSCURE
O.C.ON CENTER
OPNG OPENING
OPP OPPOSITE
OPH OPPOSITE HAND
O.D.OUTSIDE DIAMETER
OHMS OVAL HEAD MACH. SCREW
OHWS OVAL HEAD WOOD SCREW
OA OVERALL
OH OVERHEAD
O2 OXYGEN
PNT PAINT(ED)
PNL PANEL
P.T.D PAPER TOWEL DISPENSER
P.T.R.PAPER TOWEL RECEPTACLE
P.BD.PARTICLE BOARD
PTN PARTITION
PVMT PAVEMENT
PG.BD.PEG BOARD
PLAS.PLASTER
P.LAM PLASTIC LAMINATE
PL PLATE
PL.GL.PLATE GLASS
PLMB PLUMBING
PMLD PREMOLDED
PWD PLYWOOD
PT POINT
PPGL POLISHED PLATE GLASS
PPTGL POLISHED PLATE
TEMPERED GLASS
PPWGL POLISHED PLATE
WIRE GLASS
PVC POLYVINYL CHLORIDE
PCF POUNDS PER CU.FT.
PSI POUNDS PER SQ. INCH
PSF POUNDS PER SQ.FT.
P.P.POWER PANEL
PCP PRECAST CONCRETE PANEL
PRE. FAB. PREFABRICATED
PREF. PREFINISHED
PSC PRE-STRESS CONC.
PROJ PROJECTION
PL PROPERTY LINE
PTDF PRESSURE TREATED
DOUGLAS FIR
QTY QUANTITY
QT QUARRY TILE
RAD RADIUS
R.W.L.RAIN WATER LEADER
RECPT.RECEPTACLE, ELECTRIC
REC.RECESS(ED)
RE:REFER TO
R.C.P.REFLECTED CEILING PLAN
REFR.REFRIGERATOR
REG. REGISTER
REINF. REINFORCE(D)(ING)
REQ'D REQUIRED
RES RESILIENT
R.C.P.REINF. CONC. PIPE
RET RETURN
RA RETURN AIR
RVS REVERSE
REV REVISION
RH RIGHT HAND
ROW RIGHT OF WAY
R RISER
RVT RIVET
R.D.ROOF DRAIN
RFH ROOF HATCH
R.V.ROOF VENT
RFG ROOFING
RM ROOM
R.F.S.ROOM FINISH SCHEDULE
RO ROOF OPENING
RND ROUND
RBL RUBBLE STONE
S.A.M.F.SELF-ADHERED MEMBRANE
FLASHING
SDL SADDLE
S.N.C.SAN. NAP. CABINET
S.N.D.SAN.NAP.DISPOSER
STC SEALANT
STG SEATING
SECT.SECTION
S.S.SERVICE SINK
S.B.SHAMPOO BOWL
SHTH SHEATHING
SHT SHEET
SH SHELF, SHELVING
SHR SHOWER
SIM. SIMILAR
S SINK
S.DI.SOAP DISPENSER
SPKR SPEAKER
S.F.C. SPECIAL FLR. COATING
S.W.C.SPECIAL WALL COATING
S.O.G SLAB ON GRADE
SPEC.SPECIFICATIONS
SQ SQUARE
SST STAINLESS STEEL
SP STAND PIPE
STD STANDARD
STL STEEL
STER STERILIZER
SD STORM DRAIN
S.G.T.STRUCTURAL GLAZED TILE
STRUCT STRUCTURAL
SUSP.SUSPENDED
S.V.SHEET VINYL
SW SWITCH
SWBD SWITCH BOARD
SYM SYMMETRICAL
T.B.TACKBOARD
T.P.TANGENT POINT
TEL TELEPHONE
TEMP TEMPERATURE
TEMP. GL.TEMPERED GLASS
TER.TERRAZZO
TEX.TEXTURE
THK THICK(NESS)
THR THRESHOLD
T.D.TISSUE DISPENSER
T TOILET (FIXTURE)
TPH TOILET PAPER HOLDER
T&G TONGUE & GROOVE
T.O.S.TOP OF STEEL
T.O.B TOP OF BEAM
T.O.C.TOP OF COLUMN
T.O.F.TOP OF FASCIA
T.O.FTG TOP OF FOOTING
T.O.P.TOP OF PARAPET
T.O.W.TOP OF WALL
TB TOWEL BAR
TYP TYPICAL
U.C.UNDERCUT
U/C UNDER COUNTER
U.C.L.UNDER COUNTER LIGHT
U.L.UNDERWRITERS
LABORATORIES INC.
UNGND UNDERGROUND
U.H.UNIT HEATER
U.V.UNIT VENTILATOR
U.O.N.UNLESS OTHERWISE NOTED
UR URINAL
UPH.UPHOLSTERY
V.T.R.VENT THROUGH ROOF
VENT VENTILATOR
V.I.F.VERIFY IN FIELD
VERT VERTICAL
VEST VESTIBULE
V.C.T.VINYL COMPOSITION TILE
V.W.C. VINYL WALL COVERING
V VINYL
VT VINYL TILE
WSCT WAINSCOT
W WASTE
WC WATER CLOSET
W.L.WATER LINE
WS WEATHER STRIP
WT WEIGHT
WWF WELDED WIRE FABRIC
W.C.D.F.WHEELCHAIR DRINKING
FOUNTAIN
WG WIRE GLASS
W.M.P.WIRE MESH PARTITION
W/WITH
W/O WITHOUT
WD WOOD
W.R.B. WATER-RESISTANT BARRIER
(WEATHER-RESISTANT
BARRIER)
ABBREVIATIONS
*NOTE -FIRE SUPPRESSION SYSTEM BUILT INTO HOOD AND COMMERCIAL KITCHEN
2
WEST MACARTHUR
MA
I
N
S
T
R
E
E
T
55
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATEOF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
US
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
1
6
/
2
0
2
6
2
:
1
8
:
2
2
P
M
G-001
PROJECT INFORMATION
2510
Au
t
h
o
r
SHEET # SHEET NAME
1 - GENERAL
G-001 PROJECT INFORMATION
G-101 GENERAL NOTES
G-110 CALIFORNIA GREEN BUILDING STANDARD CODE
G-111 CALIFORNIA GREEN BUILDING STANDARD CODE
G-112 CALIFORNIA GREEN BUILDING STANDARD CODE
G-113 CALIFORNIA GREEN BUILDING STANDARD CODE
G-120 CODE ANALYSIS
G-140 ADA SITE AND PARKING DETAILS
G-141 ACCESSIBILITY DETAILS & NOTES
G-142 ACCESSIBILITY DETAILS & NOTES
2 - ARCHITECTURE
A-001 AS-BUILT REFERENCE
A-010 SITE PLAN
A-100 DEMO FLOOR PLAN
A-200 FLOOR PLAN
A-201 FINISH FLOOR PLAN
A-210 RCP AND ROOF PLAN
A-300 SECTIONS
A-310 EXTERIOR ELEVATIONS
A-400 ENLARGED PLANS
A-401 INTERIOR ELEVATIONS
A-402 INTERIOR ELEVATIONS
A-500 DETAILS
A-501 DETAILS
A-600 DOOR AND WINDOW SCHEDULE
A-700 EQUIPMENT CUTSHEETS
A-701 EQUIPMENT CUTSHEETS
3 - MECHANICAL
M-001 MECHANICAL COVER SHEET
M-200 MECHANICAL PLANS
M-500 MECHANICAL DETAILS
M-701 MECHANICAL CUTSHEETS
M-702 WALK-IN REFRIGERATOR
M-800 TITLE 24 COMPLIANCE
4 - ELECTRICAL
E-001 ELECTRICAL COVER SHEET
E-200 ELECTRICAL PLANS
E-600 PANEL AND SINGLE LINE DIAGRAM
E-700 ELECTRICAL CUTSHEETS
5 - PLUMBING
P-001 PLUMBING COVER SHEET
P-200 PLUMBING PLANS
P-500 PLUMBING DETAILS
P-700 PLUMBING CUTSHEETS
P-701 PLUMBING CUTSHEETS
P-800 TITLE 24 COMPLIANCE
6-SHOP DWG
1 HOOD EQUIPMENT CUTSHEETS
2 HOOD EQUIPMENT CUTSHEETS
3 HOOD EQUIPMENT CUTSHEETS
4 HOOD EQUIPMENT CUTSHEETS
5 HOOD EQUIPMENT CUTSHEETS
6 HOOD EQUIPMENT CUTSHEETS
7 HOOD EQUIPMENT CUTSHEETS
TOTAL: 49
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 04/06/2026
THESE PLANS ARE THE PROPERTY OF IDS GROUP INC., AND ARE NOT TO BE USED
FOR ANY OTHER THAN THE LOCATION SHOWN HEREON.
1. NO CHANGES ARE TO BE MADE ON THESE PLANS WITHOUT THE KNOWLEDGE OR
CONSENT OF THE ARCHITECT OR ENGINEER WHOSE SIGNATURE APPEARS
HEREON.
2. DO NOT SCALE DRAWINGS. ALL DIMENSIONS ARE TO FACE OF CONCRETE, FACE
OF CONCRETE MASONRY UNITS, CENTERLINE OF COLUMNS AND BEAMS, OR FACE
OF STUDS, UNLESS OTHERWISE NOTED. FINISH FLOOR ELEVATIONS ARE TO TOP
OF CONCRETE SLAB OR TOP OF INTERIOR PAVING UNLESS OTHERWISE NOTED.
3. NO SUBSTITUTIONS WILL BE ALLOWED WITHOUT PRIOR WRITTEN APPROVAL.
REQUEST FOR SUBSTITUTIONS SHALL BE IN ACCORDANCE WITH SECTION 01 25 00
OF SPECIFICATIONS.
A. THESE DRAWINGS DO NOT CONTAIN THE NECESSARY COMPONENTS FOR
CONSTRUCTION SAFETY.
B. ALL CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITH THE STATE
CONSTRUCTION SAFETY ORDERS ENFORCED BY THE STATE DIVISION OF
INDUSTRIAL SAFETY.
1. CONTRACTOR FOR THE PROJECT SHALL BE RESPONSIBLE FOR OBTAINING ALL
REQUIRED BUILDING PERMITS PRIOR TO COMMENCING WORK.
2. THE CONTRACTOR SHALL ENSURE THAT ALL WORK IS DONE IN A PROFESSIONAL
WORK-MAN-LIKE MANNER BY SKILLED MECHANICS AND SHALL REPLACE ANY
NEW AND/OR EXISTING MATERIALS OR ITEMS INDICATED TO REMAIN DAMAGED
BY ANY CAUSE DURING CONSTRUCTION.
3. THE CONTRACTOR AND/OR SUBCONTRACTOR SHALL, PRIOR TO THE
SUBMISSION OF HIS BID OR PERFORMANCE OF WORK, NOTIFY THE OWNER OF
ANY WORK CALLED OUT ON THE DRAWINGS OR IN THE SPECIFICATIONS IN HIS
TRADE THAT CANNOT BE FULLY GUARANTEED OR WARRANTED FROM
DEFECTIVE WORKMANSHIP OR MATERIAL DEFECTS.
4. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IF DETAILS ARE CONSIDERED
UNSOUND, UNSAFE, NOT WATERPROOF, OR NOT WITHIN CUSTOMARY TRADE
PRACTICE. IF WORK IS PERFORMED, IT WILL BE ASSUMED THAT THERE IS NO
OBJECTIONS TO THE DETAIL. DETAILS ARE INTENDED TO SHOW END RESULT OF
DESIGN, MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB CONDITIONS
AND CURRENT TRADE PRACTICE AND SHALL BE INCLUDED AS PART OF THIS
PROJECT.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FINISHES AT POINT OF
CONNECTIONS FOR ALL WORK (ARCHITECTURAL, STRUCTURAL, MECHANICAL
AND ELECTRICAL) FINISHES WILL MATCH THOSE SPECIFIED OR EXISTING IN LINE,
TEXTURE AND FINISH. SPOT PAINTING IS NOT ACCEPTABLE. NEW FINISHES
SHALL BE FROM CORNER TO CORNER, FLOOR TO CEILING, ETC.
6. UNLESS OTHERWISE NOTED, ALL MATERIALS SHALL BE NEW AND OF GOOD
QUALITY. WHERE EXISTING MATERIALS ARE INDICATED TO BE SALVAGED,
CONTRACTOR SHALL INVENTORY, CLEAN,BOX PROTECT, AND STORE ITEMS FOR
REUSE ON THE PROJECT. ITEMS NOT REUSED SHALL BE RETURNED TO OWNER.
7. COORDINATION: THE GENERAL AND EACH SUB CONTRACTOR SHALL BE
RESPONSIBLE FOR VERIFICATION AND COORDINATION WITH OTHER SUB
CONTRACTORS TO ASSURE COMPLIANCE WITH DRAWINGS AND
SPECIFICATIONS, AND THE ACCURATE LOCATION OF ARCHITECTURAL,
STRUCTURAL, MECHANICAL AND ELECTRICAL BUILDING ELEMENTS. THEIR
REQUIRED OPENINGS CLEARANCES SUPPORT SYSTEMS ARE ALL
INTERCONNECTED AND COORDINATED.
8. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL
TRADES AND FOR BEING AWARE OF ALL CONDITIONS THAT AFFECT THEIR WORK.
NOTIFY OWNER, IN WRITING, WITHIN 3 WORKING DAYS OF AWARD OF CONTRACT,
OF THE PROPOSED DELIVERY SCHEDULE, OF ANY EQUIPMENT, FINISHES OR
MATERIAL, FOR WHICH THAT SCHEDULE WILL PREVENT THE INSTALLATION FROM
BEING COMPLETED AT THE TIME OF THE SCHEDULED PROJECT COMPLETION.
9. COORDINATION OF WORK:
10. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS OF
EXISTING SITE PRIOR TO BIDDING AND START OF CONSTRUCTION. THE
CONTRACTOR SHALL REPORT TO THE ARCHITECT ALL CONDITIONS WHICH
PREVENT THE PROPER EXECUTION OF ITS WORK. THE DRAWINGS SHALL NOT
BE SCALED.
11. CONSTRUCTION SHALL COMPLY WITH APPLICABLE EDITION OF CALIFORNIA
BUILDING CODE, ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES,
ORDINANCES, LAWS, REGULATIONS AND PROTECTIVE COVENANTS GOVERNING
THE WORK. IN CASE OF CONFLICTING INFORMATION, THE MORE STRINGENT
REQUIREMENT SHALL GOVERN.
12. GENERAL CONTRACTOR TO ARRANGE INSPECTIONS AT APPROPRIATE
INTERVALS. CONTRACTOR TO INCLUDE CONSTRUCTION MANAGER BY NOTIFYING
AT LEAST 36 HOURS AHEAD OF THE CITY INSPECTION TIME.
13. ALL CONTRACTOR'S WORK SHALL BE OF THE QUALITY TO PASS INSPECTIONS BY
LOCAL AND STATE AUTHORITIES, LENDING INSTITUTIONS, THE ARCHITECT AND
ENGINEERS, INSPECTOR OF RECORD, AND OWNER. ANY ONE OR ALL OF THE
ABOVE MENTIONED INSPECTORS MAY INSPECT TRADE(S) AT ANY TIME, AND ANY
CORRECTIONS NEEDED TO MEET THE REQUIRED QUALITY OF CONSTRUCTION
SHALL BE DONE IMMEDIATELY AFTER NOTIFYING THE ARCHITECT AND THE
OWNER FOR APPROVAL.
14. THE CONTRACTOR/SUB-CONTRACTORS SHALL INSPECT THE SITE PRIOR TO
START OF CONSTRUCTION AND NOTIFY OWNER AND THE ARCHITECT OF ANY
EXISTING CONDITIONS THAT MAY AFFECT THE WORK INCLUDING ELEMENTS
THAT MAY BE SUBJECT TO DAMAGE DURING DEMOLITION AND RENOVATION. THE
CONTRACTOR SHALL FIELD VERIFY EXISTING DIMENSIONS, PRIOR TO START OF
CONSTRUCTION AND NOTIFY OWNER AND ARCHITECT OF ANY DISCREPANCIES
BETWEEN THE EXISTING DIMENSIONS AND THE DRAWING DIMENSIONS THAT MAY
AFFECT THE WORK. THE CONTRACTOR SHALL OBTAIN DIRECTION FROM OWNER
ON RESOLUTION OF THE DISCREPANCIES BETWEEN THE EXISTING CONDITIONS
AND DIMENSIONS AND DRAWINGS PRIOR TO STARTING ANY WORK THAT MAY BE
AFFECTED BY SUCH DISCREPANCIES.
15. CLEANUP: TYPICALLY EACH SUBCONTRACTOR IS HELD RESPONSIBLE FOR
CLEANUP OF THE WORK OF HIS TRADE BY THE GENERAL CONTRACTOR.
HOWEVER, THE GENERAL CONTRACTOR SHALL BE HELD SOLELY RESPONSIBLE
FOR CONTINUOUS CLEANUP AS THE JOB PROGRESSES, AND FINAL CLEANUP
UPON SUBSTANTIAL COMPLETION. THE CONTRACTOR SHALL BE RESPONSIBLE
FOR CLEANING UP AND REMOVING FROM THE JOB SITE ALL TRASH AND DEBRIS,
IMMEDIATELY UPON COMPLETION OF HIS DAILY WORK. CONTINUOUS CLEANUP
SHALL KEEP THE JOB FREE AT ALL TIMES FROM UNREASONABLE BUILDUP OF
DEBRIS, WRAPPERS, CONTAINERS, WASTE MATERIALS, ETC., WHICH MAY CAUSE
ACCIDENTS, UNDUE HARDSHIP ON THE TRADESMAN, AND WORK PROGRESS.
FINAL CLEANUP INCLUDES CLEANING OF ALL SURFACES TO A "LIKE NEW"
CONDITION AND PREPARING THE BUILDING FOR ITS INTENDED USE.
16. THE CONTRACTOR SHALL AT ALL TIMES MAINTAIN THE SITE AND ADJACENT
AREAS IN A CLEAN, NEAT, AND ORDERLY MANNER. THE CONTRACTOR SHALL BE
RESPONSIBLE ONLY FOR DEBRIS THAT IS A RESULT OF THE WORK, INCLUDING
ANY THAT MAY RESULT FROM THE WORKERS. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR PROVIDING HIS OWN REFUSE CONTAINERS AND SHALL AT NO
TIME USE THE BUILDING REFUSE CONTAINERS.
17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF
THE SITE WHILE THE JOB IS IN PROGRESS AND UNTIL THE JOB IS COMPLETED.
18. CONTRACTOR SHALL PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING
OF NOT LESS THAN 2-A OR 2-10BC WITHIN 75 FEET OF TRAVEL DISTANCE TO ALL
PORTIONS OF THE BUILD OUT AREA DURING CONSTRUCTION.
19. OBTAIN ALL CAL / OSHA CONSTRUCTION ACTIVITY PERMITS, PRIOR TO OBTAINING
THE BUILDING PERMIT, AS REQUIRED BY AND IN ACCORDANCE WITH CCR TITLE 8,
SECTION 341.
20. DEMARCATE AND NOTIFY THE REGIONAL NOTIFICATION CENTER (DIG ALERT, 811)
AT LEAST TWO WORKING DAYS PRIOR TO ANY EXCAVATIONS.
21. HOLD ON-SITE MANDATORY CONSTRUCTION AND SAFETY MEETINGS WEEKLY.
1. THE SCOPE OF THIS PROJECT IS AS GENERALLY DEPICTED IN THESE
INSTRUMENTS OF SERVICE AS PART OF THE CONTRACT DOCUMENTS. WORK
INCLUDING: POINTS OF CONNECTION, NOT SPECIFICALLY DEPICTED, THAT
NEED TO BE MADE ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR.
ALL WORK PERFORMED EVEN IN REMOTE AREAS OF THE BUILDING OR SITE,
PERTAINING TO THIS PROJECT SHALL COMPLY WITH THE INTENT OF
CONTRACT DOCUMENTS.
2. THESE CONTRACT DOCUMENTS COVER THE FURNISHING AND INSTALLATION
OF MATERIALS AND WORK AS CALLED FOR ON THE DRAWINGS OR IN THE
SPECIFICATIONS (OR IN BOTH) WHICH ARE BOUND SEPARATELY AND ARE A
PART OF THE CONTRACT. IT SHALL BE THE RESPONSIBILITY OF EACH
CONTRACTOR TO CHECK WITH THE ARCHITECTURAL DRAWINGS BEFORE
FINALIZING THEIR BID AND BEFORE THE INSTALLATION OF THEIR WORK. ANY
DISCREPANCY BETWEEN THE ARCHITECTURAL AND THE CONSULTING
ENGINEER(S) DRAWINGS SHALL BE BROUGHT TO THE ARCHITECTS ATTENTION
BY WRITTEN REQUEST FOR CLARIFICATION. ANY WORK INSTALLED IN
CONFLICT WITH THE ARCHITECTURAL DRAWINGS SHALL BE CORRECTED BY
THE CONTRACTOR AT HIS OWN EXPENSE AND AT NO EXPENSE TO THE
OWNER OR ARCHITECT.
3. GENERAL REQUIREMENTS, DESCRIBING THE PROJECT'S ADMINISTRATIVE
REQUIREMENTS AND THE PHYSICAL ASPECTS OF CONSTRUCTION, ARE
PROVIDED WITHIN EACH PROFESSIONAL DISCIPLINE'S PROJECT
SPECIFICATION AND GENERAL NOTATION. GENERAL REQUIREMENTS ARE NOT
LIMITED TO THE INSTRUMENT OF SERVICES AND MAY EXTEND TO THE
CONTRACT DOCUMENTS AND OWNER REQUIREMENTS.
4. THE PROJECT SPECIFICATIONS CONSISTING OF THE WRITTEN REQUIREMENTS
FOR MATERIAL, EQUIPMENT, SYSTEMS, STANDARDS AND WORKMANSHIP FOR
THE WORK, AND PERFORMANCE OF RELATED SERVICES ARE CONTAINED
WITHIN EACH OF THE ARCHITECT AND THE ARCHITECT'S INSTRUMENT OF
SERVICES. REFER TO GENERAL NOTES FOR ADDITIONAL PROJECT
STANDARDS INFORMATION. DOCUMENTS INDICATED AS 'REFERENCE
DOCUMENT' ARE NOT CONSIDERED INSTRUMENTS OF SERVICES AND ARE
BEING ISSUED TO PROVIDE ASSISTANCE DURING THE REGULATORY AGENCY
CONTRACT DOCUMENT REVIEW.
5. OVERALL AND BUILDING SCOPE DIAGRAMS PROVIDE GUIDLINE TO IDENTIFY
THE LIMIT OF SCOPE.
6. THESE DRAWINGS ARE BASED ON FIELD OBSERVATION AND DOCUMENTS
FURNISHED BY THE OWNER. THE ARCHITECT SHALL BE NOTIFIED
IMMEDIATELY BY THE CONTRACTOR OF ANY DISCREPANCIES OR OTHER
QUESTIONS PERTAINING TO THE CONTRACT DOCUMENTS.. IF OBVIOUS
OMISSIONS OR CONTRADICTORY SITUATIONS IN THE CONTRACT DOCUMENTS
ARE DISCOVERED TO EXIST, THEY SHOULD BE IMMEDIATELY CALLED TO THE
ATTENTION OF ARCHITECT FOR CLARIFICATION.
7. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALE UNLESS OTHERWISE
NOTED BY A PLUS/MINUS DIMENSION. DETAILED DRAWINGS HAVE
PRECEDENCE OVER SMALL SCALE DRAWINGS. CONTRACTOR SHALL CHECK
ACCURACY OF DIMENSIONS ON PLANS WITH ACTUAL FIELD DIMENSIONS. THE
CONTRACTOR SHALL REPORT TO THE ARCHITECT ALL CONDITIONS WHICH
PREVENT THE PROPER EXECUTION OF ITS WORK. CONTRACTOR SHALL NOT
START ANY CONSTRUCTION OR ANY OFF-SITE FABRICATION OF MATERIALS
UNTIL THE DRAWINGS DIMENSIONS ARE VERIFIED WITH ACTUAL FIELD
CONDITIONS. DO NOT SCALE DRAWINGS.
8. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY
ERRORS, DISCREPANCIES OR OMISSIONS THAT THE CONTRACTOR FAILED TO
NOTIFY THE ARCHITECT OF BEFORE CONSTRUCTION AND/OR FABRICATION OF
THE WORK.
9. WORK INCLUDES DEMOLITION, REMOVAL AND REINSTALLATION WHERE
REQUIRED. REMOVE, REVISE, RELOCATE AND REINSTALL AS REQUIRED.
10. IT IS NOT THE RESPONSIBILITY OF THE ARCHITECT OR GENERAL CONTRACTOR
TO ENSURE THAT AREAS OF THE BUILDING, NOT DESCRIBED WITHIN THE
SCOPE OF THIS PROJECT COMPLY WITH CURRENT CALIFORNIA BUILDING
CODES, LOCAL CODES AND ORDINANCES (ORD. NO. 2024-05) . IT IS THE
RESPONSIBILITY OF THE OWNER TO MAINTAIN THE BUILDING, SO AS TO
PROVIDE FOR THE SAFETY AND COMFORT OF THE OCCUPANTS. THIS
INCLUDES ALL LIFE SAFETY FEATURES SUCH AS FIRE ALARM, FIRE-
SPRINKLERS, NURSE CALL, EXIT ENCLOSURE, HANDICAP ACCESSIBILITY, ETC..
THIS ALSO INCLUDES MAINTAINING THE BUILDING FREE OF HAZARDOUS
MATERIALS I.E., CHEMICALS AS DESCRIBED BY STATE OR FEDERAL AGENCIES
AS "HAZARDOUS", INCLUDING ASBESTOS.
1. THE CONTRACTOR SHALL INSTALL A VISUAL BARRIER (E.G., GREEN MESH FABRIC)
ALONG THE PERIMETER OF CONSTRUCTION SITES FOR VERTICAL CONSTRUCTION
PROJECTS. THIS REQUIREMENT SHALL BE SUBMITTED TO ARCHITECT AS A
CONTRACTOR SUBMITTAL AND VERIFIED BY THE COMMUNITY DEVELOPMENT
DEPARTMENT PRIOR TO SITE WORK.
2. DUST CONTROL. THE CONTRACTOR SHALL BE REQUIRED TO COMPLY WITH
SCAQMD RULES 402 AND 403, WHICH SHALL ASSIST IN REDUCING SHORT-TERM AIR
POLLUTANT EMISSIONS. SCAQMD RULE 402 REQUIRES THAT AIR POLLUTANT
EMISSIONS NOT BE A NUISANCE OFF SITE. SCAQMD RULE 403 (TABLES 1, 2, AND 3
OF RULE 403) REQUIRES THAT FUGITIVE DUST BE CONTROLLED WITH THE BEST
AVAILABLE CONTROL MEASURES SO THAT THE PRESENCE OF SUCH DUST DOES
NOT REMAIN VISIBLE IN THE ATMOSPHERE BEYOND THE PROPERTY LINE OF THE
EMISSION SOURCE. THIS REQUIREMENT SHALL BESUBMITTED TO ARCHITECT AS A
CONTRACTOR SUBMITTAL AND VERIFIED BY THE COMMUNITY DEVELOPMENT
DEPARTMENT PRIOR TO SITE WORK.
3. ARCHITECTURAL COATINGS. ARCHITECTURAL COATINGS SHALL BE SELECTED SO
THAT THE VOC CONTENT OF THE COATINGS IS COMPLIANT WITH SCAQMD RULE
1113. THIS REQUIREMENT SHALL BE SUBMITTED TO THE ARCHITECT AS A
CONTRACTOR SUBMITTAL AND VERIFIED BY THE COMMUNITY DEVELOPMENT
DEPARTMENT PRIOR TO COATING WORK.
4. CONTRACTOR TO REDUCE PROJECT CONSTRUCTION AIR QUALITY IMPACTS
DURING CONSTRUCTION. THE FOLLOWING TO BE IMPLEMENTED BY CONTRACTOR
DURING CONSTRUCTION:
CONSTRUCTION ACTIVITIES INCLUDING ADDITIONS, ALTERATIONS, AND DEMOLITIONS
SHALL PROVIDE PEDESTRIAN PROTECTION PURSUANT TO SECTION 3306 OF THE
CALIFORNIA BUILDING CODE. TO DETERMINE THE TYPE OF PROTECTION REQUIRED
FOR PEDESTRIANS,MEASURE THE ULTIMATE HEIGHT OF CONSTRUCTION WITH
CONSIDERATION FOR BUILDING SETBACKS AND PROJECTIONS FROM THE BUILDING.
FOR SLOPING SITES, MEASURE THE HEIGHT OF THE BUILDING FROM CONSTRUCTION
EDGE OF THE WALKWAY AND THE SETBACK DISTANCE BETWEEN THE WALKWAY AND
THE BUILDING LINE.
BELOW ARE REQUIREMENTS TO BE ADDRESSED IN THE DESIGN OF PEDESTRIAN
PROTECTIONS:
1. WALKWAYS SHALL PROVIDE SUFFICIENT WIDTH WITH THE MINIMUM OF 4 FT.
CLEAR.
2. DIRECTIONAL BARRICADES SHELL BE PROVIDED AS NEEDED WHERE THE
WALKWAY EXTENDS INTO THE STREET.
3. CONSTRUCTION RAILINGS SHALL BE AT LEAST 42 INCHES IN HEIGHT.
4. BARRIERS SHALL BE A MINIMUM OF 8 FT. IN HEIGHT AND BE DESIGNED TO RESIST
LOADS REQUIRED.
5. SUCH PROTECTION SHALL BE MAINTAINED IN PLACE AND KEPT IN GOOD ORDER.
UNTIL WORK IS COMPLETED.
6. WHENEVER A WALKWAY MUST EXTEND INTO THE ROADWAY, A RAILING IS
REQUIRED ON THE STREET SIDE.
7. CONSTRUCTION STAFF TO ENTER PREMISES THROUGH REAR ENTRANCE.
A. THE CONTRACTORS SHALL PROVIDE AND COORDINATE THE EXACT
DIMENSIONS SIZES AND POSITIONS OF ALL SYSTEMS, EQUIPMENT,
MOUNTING, AND ATTACHMENTS RELATING TO THE WORK.
B. THE CONTRACTOR SHALL PROVIDE AND COORDINATE ALL DIMENSIONS
SIZES AND POSITIONS OF OPENINGS IN SLABS AND WALLS NECESSARY TO
THE INSTALLATION OF THE WORK.
C. ALL EQUIPMENT, CONTROLS AND TERMINATIONS SHALL BE POSITIONS FOR
SAFE, DIRECT AND EASY ACCESS.
D. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CHECK WITH
THE APPROVED DRAWINGS BEFORE PROCEEDING WITH INSTALLATION OF
CIVIL, STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL WORK.
SHOULD THERE BE ANY DISCREPANCIES BETWEEN THE ARCHITECT'S AND
THE ENGINEER'S DRAWINGS AND SPECIFICATIONS THAT WOULD CAUSE A
CONFLICT. IT SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION FOR
CLARIFICATION PRIOR TO INSTALLATION OF SAID WORK. ANY WORK
INSTALLED IN CONFLICT WITH THE ARCHITECTURAL DRAWINGS SHALL BE
CORRECTED BY THE CONTRACTOR AT HIS EXPENSE AND AT NO ADDITIONAL
EXPENSE TO THE OWNER OR ARCHITECT.
E. CONTRACTOR SHALL COORDINATE WORK WITH HVAC, MECHANICAL,
ELECTRICAL, PLUMBING, DESIGN BUILD FIRE PROTECTION AND
STRUCTURAL DRAWINGS AND REPORT TO IDS GROUP ANY DISCREPANCIES
FOR CORRECTION AND ADJUSTMENT PRIOR TO START OF WORK. NO
ALLOWANCE WILL BE MADE FOR INCREASED COST DUE TO THE
CONTRACTOR’S LACK OF COORDINATION.
A. WATER ACTIVE SITES AT LEAST TWICE DAILY.
B. APPLY WATER THREE TIMES DAILY, OR NON-TOXIC SOIL STABILIZERS
ACCORDING TO MANUFACTURERS' SPECIFICATIONS, TO ALL UNPAVED
PARKING OR STAGING AREAS OR UNPAVED ROAD SURFACES.
C. ALL TRUCKS HAULING DIRT, SAND, SOIL, OR OTHER LOOSE MATERIALS ARE
TO BE COVERED.
D. PAVE ROAD AND ROAD SHOULDERS.
E. INSTALL WHEEL WASHERS WHERE VEHICLES ENTER AND EXIT THE
CONSTRUCTION SITE ONTO PAVED ROADS OR WASH OFF TRUCKS AND ANY
EQUIPMENT LEAVING THE SITE EACH TRIP.
F. APPLY NON-TOXIC SOIL STABILIZERS ACCORDING TO MANUFACTURERS'
SPECIFICATIONS TO ALL INACTIVE CONSTRUCTION AREAS (PREVIOUSLY
GRADED AREAS INACTIVE FOR TEN DAYS OR MORE).
G. SUSPEND ALL EXCAVATING AND GRADING OPERATIONS WHEN WIND
SPEEDS(AS INSTANTANEOUS GUSTS) EXCEED 25 MILES PER HOUR.
H. SWEEP STREETS AT THE END OF THE DAY IF VISIBLE SOIL IS CARRIED ONTO
ADJACENT PUBLIC PAVED ROADS.
I. APPOINT A CONSTRUCTION RELATIONS OFFICER TO ACT AS A COMMUNITY
LIAISON CONCERNING ON-SITE CONSTRUCTION ACTIVITY, INCLUDING
RESOLUTION OF ISSUES RELATED TO PM10 GENERATION.
J. REQUIRE ALL VEHICLES AND EQUIPMENT TO BE PROPERLY TUNED AND
MAINTAINED ACCORDING TO MANUFACTURERS' SPECIFICATIONS.
A. WINDOWS: ALL WINDOWS AND SLIDING GLASS DOORS SHALL BE WELL
FITTED, WELL WEATHER-STRIPPED ASSEMBLIES AND SHALL HAVE A MIN.
UPGRADED SOUND TRANSMISSION CLASS (STC) RATING OF 30 FOR ALL
RESIDENTIAL UNITS WITHIN THE PROJECT BUILDING.
B. DOORS: ALL EXTERIOR DOORS SHALL BE WELL WEATHER-STRIPPED SOLID
CORE ASSEMBLIES AT LEAST ONE AND THREE-FOURTH-INCH THICK.
C. WALLS: AT ANY PENETRATIONS OF EXTERIOR WALLS BY PIPES, DUCTS, OR
CONDUITS, THE SPACE BETWEEN THE WALL AND PIPES, DUCTS, OR
CONDUITS SHALL BE CAULKED OR FILLED WITH MORTAR TO FOR AN AIRTIGHT
SEAL.
D. ROOF: ROOF SHEATHING OF WOOD CONSTRUCTION SHALL BE WELL FITTED
OR CAULKED PLYWOOD OF AT LEAST 1/2" THICK. CEILING SHALL BE WELL
FITTED, FULLY SEALED GYPSUM BOARD OF AT LEAST 1/2" THICK. INSULATION
WITH AT LEAST A RATING OF R-19 SHALL BE USED IN THE ATTIC SPACE.
E. VENTILATION: ARRANGEMENTS FOR ANY HABITABLE ROOM SHALL BE SUCH
THAT ANY EXTERIOR DOOR OR WINDOW CAN BE KEPT CLOSED WHEN THE
ROOM IS IN USE AND STILL RECEIVE CIRCULATED AIR. A FORCED AIR
CIRCULATION SYSTEM (E.G. AIR CONDITIONING) OR ACTIVE VENTILATION
SYSTEM (E.G. FRESH AIR SUPPLY) SHALL BE PROVIDED WHICH SATISFIES THE
REQUIREMENTS OF THE UNIFORM BUILDING CODE.
8. CONTRACTOR TO SUBMIT EVIDENCE TO THE ARCHITECT AND OWNER THAT THE
FOLLOWING NOISE REDUCTION MEASURES AS STATED ON THE CONSTRUCTION
PLANS AND SPECIFICATIONS ARE BEING IMPLEMENTED:
A. CONSTRUCTION TRAFFIC SHALL BE LIMITED TO HAUL ROUTES ESTABLISHED
BY THE LOCAL CITY ORDINANCE.
B. STATIONARY EQUIPMENT (SUCH AS GENERATORS AND AIR COMPRESSORS)
SHALL BE LOCATED AS FAR FROM RESIDENCES, INCLUDING HOTEL ROOMS,
AS FEASIBLE.
C. EQUIPMENT MAINTENANCE AND STAGING AREAS SHALL BE LOCATED AS FAR
AWAY FROM RESIDENCES AS FEASIBLE.
D. CONSTRUCTION EQUIPMENT SHALL BE FITTED WITH MANUFACTURER'S
STANDARD, OR BETTER, NOISE-SHIELDING AND MUFFLING DEVICES TO
REDUCE NOISE LEVELS TO THE MAXIMUM EXTENT FEASIBLE.
E. THE PROJECT OWNER/DEVELOPER SHALL DESIGNATE A CONSTRUCTION
COMPLAINT MANAGER FOR THE PROJECT. A TELEPHONE CONTACT NUMBER
SHALL BE CLEARLY POSTED AT ALL ACTIVE ACCESS POINTS.
5. NOISE GENERATING: CONSTRUCTION, REPAIR, REMODELING, OR GRADING IS
ALLOWED, PROVIDED IT DOES NOT OCCUR BETWEEN 8:00 P.M. AND 7:00 A.M. ON
WEEKDAYS (INCLUDING SATURDAY) OR AT ANY TIME ON A SUNDAY OR FEDERAL
HOLIDAY
6. CONTRACTOR TO INSTALL WINDOW ASSEMBLIES THAT ARE TESTED AND
CERTIFIED TO PREVENT THE INTRUSION OF EXTERIOR NOISE SO THAT THE
INTERIOR NOISE LEVEL WITH WINDOWS CLOSED, ATTRIBUTABLE TO EXTERIOR
SOURCES, SHALL NOT EXCEED 45 DBA CNEL IN ANY HABITABLE ROOM. THIS
REQUIREMENT SHALL BE SUBMITTED TO ARCHITECT AS A CONTRACTOR
SUBMITTAL.
7. PER CITY ORDINANCE, CONTRACTOR TO SATISFY CITY GUIDELINES OF 45 DBA
CNEL INTERIOR NOISE LEVEL STANDARD, ALL UNITS WILL REQUIRED A MIN.
EXTERIOR TO INTERIOR NOISE REDUCTION (NR) OF UP TO 23.8 DBA AND A
WINDOWS CLOSED CONDITION REQUIRING A MEANS OF MECHANICAL
VENTILATION (E.G. AIR CONDITIONING). IN ORDER TO MEET THE CITY GUIDELINES
OF 45 DBA CNEL INTERIOR NOISE STANDARDS THE PROJECT SHALL PROVIDE THE
FOLLOWING NOISE MITIGATION MEASURES:1. EXIT DOORS SHALL BE OF THE PIVOTED OR IDE-HINGEDSWINGING TYPE. EXIT
DOORS SHALL SWING IN THE DIRECTION OF EXIT TRAVEL W HEN THE AREA SERVED
HAS AN OCCUPANT LOAD OF 50 OR MORE.
2. EVERY EXIT DOOR SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A
KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. NOTE ALSO THAT FLUSH BOLTS
OR SURFACE BOLTS ARE PROHIBITED.
3. PANIC HARDWARE SHALL BE PROVIDED ON EXIT DOORS OF ROOMS, CORRIDORS,
STAIRWAYS, HANDLING AN OCCUPANT CAPACITY OF 50 OR MORE PERSONS.
4. EXIT SIGNS SHALL BE INSTALLED AT REQUIRED EXIT DOORWAYS AND WHERE
OTHERWISE NECESSARY TO CLEARLY INDICATE THE DIRECTION OF EGRESS IN
COMPLIANCE WITH THE CODE OF JURISDICTION.
5. THE FORCE FOR PUSHING OR PULLING OPEN INTERIOR SWINGING EGRESS DOORS,
OTHER THAN FIRE DOORS, SHALL NOT EXCEED 5 POUNDS. THESE FORCES DO NOT
APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE
OTHER DEVICES THAT HOLD THE DOOR IN A CLOSED POSITION. FOR OTHER
SWINGING DOORS, AS WELL AS SLIDING AND FOLDING DOORS, THE DOOR LATCH
SHALL RELEASE WHEN SUBJECTED TO A 15-POUND FORCE. THE DOOR SHALL BE
SET IN MOTION WHEN SUBJECTED TO A 30-POUND FORCE. THE DOOR SHALL
SWING TO A FULL-OPEN POSITION WHEN SUBJECTED TO A 15-POUND FORCE.
FORCES SHALL BE APPLIED TO THE LATCH SIDE OF THE DOOR.
6. EACH DOOR IN A MEANS OF EGRESS FROM A GROUP 'A' OCCUPANCY SHALL NOT
BE PROVIDED WITH A LATCH OR LOCK UNLESS IT IS PANIC HARDWARE OR FIRE
EXIT HARDWARE (CBC 1008.1.9).
7. DOOR HANDLES, LOCK AND OTHER OPERATING DEVICES SHALL BE INSTALLED AT A
MIN. 34" AND A MAX. 44" A.F.F.
8. EXIT SIGNS SHALL BE CONNECTED TO AN EMERGENCY POWER SYSTEM THAT WILL
PROVIDE AN ILLUMINATION OF NOT LESS THAT 90min. IN CASE OF PRIMARY POWER
LOSS (CBC 1011.2 - 1011.5.3)
9. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BE ILLUMINATED
AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS
OCCUPIED.
1. FURNISH AND INSTALL SUPPORTS AND OTHER NECESSARY FINISH MATERIALS FOR
A COMPLETE SIGNAGE INSTALLATION.
2. HANDICAPPED SIGNAGE / IDENTIFICATION
A. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE THE STANDARD
USED TO IDENTIFY FACILITIES THAT ARE ACCESSIBLE TO AND USEABLE BY
PHYSICALLY HANDICAPPED PERSONS.
B. LETTERS AND NUMBERS ON SIGNS HAVE A WIDTH TO HEIGHT RATIO OF
BETWEEN 3:5 AND 1:1 AND STROKE WIDTH TO HEIGHT RATIO OF BETWEEN 1:5
AND 1:10.
C. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND,
EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS
ON A LIGHT BACKGROUND.
D. ALL BUILDING ENTRANCES THAT ARE ACCESSIBLE TO AND USABLE BY
PHYSICALLY HANDICAPPED PERSONS SHALL BE IDENTIFIED WITH AT LEAST
ONE STANDARD SIGN AND WITH ADDITIONAL DIRECTIONAL SIGNS AS REQUIRED
TO BE VISIBLE TO PERSONS ALONG APPROACHING PEDESTRIAN WAYS.
E. ALL SANITARY FACILITIES WILL BE PROVIDED WITH APPROPRIATE
IDENTIFICATION SYMBOLS.
1. ALL GLAZING SHALL COMPLY WITH C.P.S.C. 16 C.F.R. AND CBC.
2. GLASS DOORS, ADJACENT PANELS AND ALL GLAZED OPENINGS SHALL BE
APPROVED FOR IMPACT HAZARD PER C.B.C. SECTION 2406. PROVIDE
IDENTIFICATION OF GLAZING PER SECTION 2406.2
3. PROVIDE TEMPERED GLASS AS REQUIRED BY CBC SECTION 2406 AND BY OTHER
APPLICABLE CODES.
1. MECHANICAL DUCTS, ETC. PENETRATING FIRE-RATED CEILINGS AND FIRE WALLS
SHALL BE CORRESPONDINGLY RATED OR DAMPERED. CABINETS, ELECTRICAL
PANELS, LIGHTS, ETC. RECESSED INTO FIRE RATED WALLS OR CEILINGS SHALL BE
BACKED WITH CORRESPONDING FIRE-RESISTIVE CONSTRUCTION AS REQUIRED TO
MAINTAIN THE INTEGRITY OF THE FIRE PROTECTION.
2. FIRE RESISTIVE ASSEMBLIES FOR PROTECTION OF OPENINGS SHALL COMPLY WITH
CBC CHAPTER 7.
3. PENETRATION OF FIRE RATED ASSEMBLIES WHICH REQUIRE OPENING
PROTECTION SHALL BE FIRE STOPPED. FIRE STOPPING SHALL BE IDENTICAL TO AN
APPROVED UNDERWRITERS LABORATORIES (UL) LISTED ASSEMBLY WITH AN "F" OF
"T" RATING. PENETRATIONS MUST ALSO CONSIST OF APPROVED MATERIALS FOR
THROUGH WALL PENETRATIONS FIRE STOP SYSTMEMS AS PRESCRIBED IN CBC
STANDARD 7-5 FIRE RATING FOR FIRE STOP SYSTEMS SHALL BE EQUAL TO THE
ASSEMBLY PENETRATED. (709.6, CBC)
4. SHAFT ENCLOSURES: OPENINGS EXTENDING VERTICALLY THROUGH FLOORS
SHALL BE ENCLOSED IN A SHAFT OF 1-HOUR FIRE-RESISTIVE CONSTRUCTION IF
PENETRATING A 1-HOUR FIRE RATED FLOOR ASSEMBLY. SHAFTS SHALL INCLUDE
A GYPSUM BOARD HORIZONTAL TERMINATION AT BOTTOM, ENGINEERED BY
GENERAL CONTRACTOR. PROTECTION FOR STAIRWAYS SHALL BE AS SPECIFIED IN
CODE OF JURISDICTION.
3. AREA AND OCCUPANCY SIGNAGE REQUIREMENTS OCCUPANT LOAD SIGN SHALL BE
POSTED IN EACH MEETING ROOM, ASSEMBLY ROOM OR SIMILAR PURPOSE ROOM
HAVING AN OCCUPANT LOAD OF 50 OR MORE.
4. EXIT SIGNS SHALL BE POSTED OVER EXITS DOORS SERVING 50 OR MORE AND ALL
HAZARDOUS AREAS. MINIMUM LETTER HEIGHT IS 6" AND SHALL CONFORM WITH CBC
AND LOCAL CODES. CBC SECTION 1003.2.8 AND UFC SECTION 12113A. SEE
ELECTRICAL PLANS FOR LOCATIONS AND FURTHER INFO.
5. AN APPROVED SIGN SHALL BE LOCATED AT EACH FLOOR LEVEL LANDING IN ALL
ENCLOSED STAIRWAYS. THE SIGN SHALL INDICATE FLOOR LEVEL, TERMINUS OF THE
TOP AND BOTTOM OF THE STAIRWAY, AND THE IDENTIFICATION OF THE STAIRWAY.
1. THE CONTRACTOR SHALL IN THE WORK OF ALL TRADES, PERFORM ALL CUTTING,
PATCHING, REPAIRING, RESTORING AND THE LIKE NECESSARY TO COMPLETE
THE WORK AND TO RESTORE ANY DAMAGED OR AFFECTED SURFACES
RESULTING FROM THE WORK OF THIS CONTRACT TO THEIR ORIGINAL CONDITION
TO THE SATISFACTION OF THE OWNERS AND THE ARCHITECT.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING, FITTING, PATCHING,
AND FIRE SAFING METHODS REQUIRED TO COMPLETE THE WORK INCLUDING BUT
NOT LIMITED TO THE FOLLOWING:
A. UNCOVERED PORTIONS OF THE WORK USED TO PROVIDE FOR
INSTALLATION OF UNSCHEDULED WORK.
B. REMOVE AND REPLACE DEFECTIVE WORK.
C. REMOVE AND REPLACE WORK NOT CONFORMING TO REQUIREMENTS OF
CONTRACT DOCUMENTS.
D. PROVIDE ROUTINE PENETRATIONS OF NON-STRUCTURAL SURFACES FOR
INSTALLATION OF PIPING AND ELECTRICAL CONDUIT.
E. REMOVE EXISTING WORK INDICATED IN THE DOCUMENTS AND AS MAY BE
REQUIRED TO PERMIT THE PROPER INSTALLATION OF NEW WORK THAT
FORMS PART OF HIS CONTRACT. ALL CUTTING,REPAIRING AND/OR PATCHING
NECESSARY IN CONNECTION WITH SUCH REMOVALS SHALL BE DONE
WITHOUT EXTRA CHARGE, WHETHER OR NOT EVERY ITEM MAY BE
SPECIFICALLY DESCRIBED.
3. PROCEDURES FOR NON-STRUCTURAL CUTTING AND PATCHING:
A. PROVIDE ADEQUATE TEMPORARY SUPPORT AS NECESSARY TO ASSURE THE
STRUCTURAL VALUE INTEGRITY OF THE AFFECTED PORTION OF THE WORK.
B. PROVIDE DEVICES AND METHODS TO PROTECT OTHER PORTIONS OF THE
PROJECT FROM DAMAGE.
C. PROVIDE PROTECTION FROM THE ELEMENTS FOR THAT PORTION OF THE
PROJECT WHICH MAY BE EXPOSED BY CUTTING AND PATCHING WORK.
D. EXECUTE CUTTING BY METHODS WHICH WILL PREVENT DAMAGE TO OTHER
WORK, AND WILL PROVIDE PROPER SURFACES TO RECEIVE INSTALLATION OR
REPAIRS.
E. EXECUTE FITTING AND ADJUSTMENT OF PRODUCTS TO PROVIDE A
FINISHED INSTALLATION TO COMPLY WITH SPECIFIED PRODUCTS,
FUNCTIONS, TOLERANCES AND FINISHES, AND MANUFACTURER'S CRITERIA.
F. RESTORE WORK WHICH HAS BEEN CUT OR REMOVED. INSTALL NEW
PRODUCTS TO PROVIDE COMPLETE WORK IN ACCORDANCE WITH
REQUIREMENTS OF CONTRACT DOCUMENTS.
G. REFINISH ENTIRE SURFACE AS NECESSARY TO PROVIDE AN EVEN FINISH
TO MATCH ADJACENT FINISHES.
CUTTING AND PATCHING
INSTRUMENT OF SERVICE CONTRACTOR OBLIGATIONS
EXITS
DOORS
1. DOORS IN RATED WALLS SHALL CONSIST OF SELF-CLOSING, SELF-LATCHING
ASSEMBLIES WITH SMOKE AND DRAFT SEALS AT HEAD AND JAMBS. DOOR
ASSEMBLY RATINGS SHALL BE AS INDICATED ON DOOR SCHEDULE. HOLD OPEN
DEVICES ON RATED ASSEMBLIES SHALL BE MAGNETICALLY OPERATED AND
ACTIVIATED BY SMOKE DETECTORS.
2. DOOR SIZES SHOWN ON DOOR SCHEDULE ARE OPENING SIZES. ALLOWANCE FOR
THRESHOLDS, ECT., SHALL BE TAKEN OFF THE DOOR. DOORS AND FRAMES
SHALL BE REINFORCED WHERE REQUIRED FOR CLOSERS, STOPS, AND
HARDWARE.
3. AIR LEAKAGE AT EXTERIOR DOORS SHALL BE LIMITED BY THE FOLLOWING:
A. ALL DOORS SHALL BE PROVIDED WITH A SEAL, ASTRAGAL, OR BAFFLE AT THE
HEAD AND SILL.
B. DOORS MOUNTED ON EITHER THE INSIDE OR OUTSIDE OF AN EXTERIOR WALL
SHALL HAVE A MINIMUM 1/2" LAP AT EACH JAMB.
C. DOORS REQUIRING VERTICAL TRACK OR GUIDES SHALL USE A CONTINUOUS
MOUNTING ANGLE, SEALED IN ACCORDANCE WITH "G" LISTED HERE.
D. DOORS MOUNTED BETWEEN THE JAMBS SHALL HAVE A CONTINUOUS SEAL OR
BAFFLE AT EACH JAMB.
E. MEETING RAILS OR SECTION DOORS AND MEETING STILES OR RAILS OR BI-
PARTING DOORS SHALL BE PROVIDED WITH A SEAL, ASTRAGAL, OR BAFFLE.
F. SWINGING AND REVOLVING DOORS SHALL BE WEATHERSTRIPPED AT THE
HEAD, SILL AND JAMBS.
G. OPEN EXTERIOR JOINTS AROUND WINDOW AND DOOR FRAMES, BETWEEN
WALL AND FOUNDATIONS, BETWEEN WALL AND ROOF, BETWEEN WALL
PANELS, AT PENETRATIONS OF UTILITY SERVICES THROUGH WALLS, FLOORS
AND ROOFS AND ALL OTHER OPENINGS IN THE EXTERIOR ENVELOPE SHALL
BE SEALED, CAULKED, GASKETED, OR WEATHERSTRIPPED TO LIMIT AIR
LEAKAGE.
WOOD WORK
1. OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACE WILL BE
FLUSH. IF STRUCTURAL PANELS ARE REQUIRED ON A WALL PLANE, THE ENTIRE
WALL PLANE SHALL BE FURRED OR FINISHED FLUSH.
2. INSTALL METAL CORNER BEADS AT ALL EXPOSED WALLBOARD EDGES. INSTALL
CASING BEADS WHEREVER WALLBOARD, PLASTER, ETC. ABUTS A DISSIMILAR
FINISH MATERIAL AND PROVIDE SEALANT AS REQUIRED.
3. GYPSUM BOARD SHALL EXTEND TO UNDERSIDE OF STRUCTURE ABOVE AT ALL
EXTERIOR PERIMETER WALLS
1. THE CONSTRUCTION OR DEMOLITION OF ANY BUILDING, STRUCTURE, SCAFFOLDING
OR FALSEWORK MORE THAN 3 STORIES OR 36'-0" IN HEIGHT, REQUIRES A PERMIT
FROM THE STATE OF CALIFORNIA DIVISION OF INDUSTRIAL SAFETY PRIOR TO THE
ISSUANCE OF A BUILDING PERMIT. ( 1PC.B.9 )
2. A SEPARATE INTERIOR IMPROVEMENT PERMIT IS REQUIRED FOR ANY TENANT
IMPROVEMENT IN THIS BUILDING.
3. A PERMIT FROM THE DEPARTMENT OF PUBLIC WORKS IS REQUIRED FOR A
PROTECTION FENCE OR CANOPY ON OR OVER ANY STREET OR PUBLIC SPACE.
PROTECTION OF PEDESTRIANS DURING CONSTRUCTION SHALL BE PROVIDED PER
C.B.C. SECTION 3303.
4. ALL ROOMS ARE REQUIRED TO BE MARKED WITH APPROVED SIGNAGE.
5. OBTAIN PERMIT FROM CITY ENGINEER PRIOR TO DOING ANY SIDEWALK AND CURB
WORK.
6. SEPARATE PERMITS SHALL BE OBTAINED FOR SIGNS, FENCES, TRASH ENCLOSURES,
RETAINING WALLS, PLANTERS, AND POOLS.
7. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN AND
SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. REFER TO
SHEET G-001 FOR LIST OF DEFERRED SUBMITTALS.
8. ALL LEVELS REFERENCE POINTS ABOVE PODIUM LEVEL ARE TAKEN FROM TOP OF
SHEATHING. DIMENSIONS ON ELEVATIONS, SECTIONS AND WALL SECTIONS ARE
REFERENCED TO THESE POINTS, UNLESS NOTED.
PERMIT
GENERALCONTRACTOR MITIGATION OBLIGATIONS
MONITORING AND REPORTING PROGRAM
CODES
1. CONSTRUCTION SHALL COMPLY WITH APPLICABLE EDITION OF CALIFORNIA BUILDING CODE,
ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES, ORDINANCES, LAWS, REGULATIONS
AND PROTECTIVE COVENANTS GOVERNING THE WORK. IN CASE OF CONFLICTS, THE
MORE STRINGENT REQUIREMENT SHALL GOVERN.
SIGNAGES
FIELD APPLICATION OF PEDESTRIAN
PROTECTION:
GLAZING
RATED ASSEMBLY PENETRATIONS
DESIGNATED CONSTRUCTION MANAGER TO BE PHIL LEVESQUE (714) 483-3915.
CONSTRUCTION MANAGER TO BE INVITED TO ALL WEEKLY PROJECT MEETINGS
TO VERIFY QUALITY CONTROL MEASURES AND SCHEDULE.
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATEOF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
1
6
/
2
0
2
6
2
:
1
8
:
2
3
P
M
G-101
GENERAL NOTES
2510
Au
t
h
o
r
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 04/06/2026
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATEOF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
1
6
/
2
0
2
6
2
:
1
8
:
2
7
P
M
G-110
CALIFORNIA GREEN
BUILDING STANDARD
CODE
2510
Au
t
h
o
r
Y
N/A
ARCH
ITECT
N/A
N/A
N/A
N/A
N/A
N/A
N/A
X
X
X
X
X
X
X
X
X
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 04/06/2026
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATEOF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
1
6
/
2
0
2
6
2
:
1
8
:
3
0
P
M
G-111
CALIFORNIA GREEN
BUILDING STANDARD
CODE
2510
Au
t
h
o
r
N/A
N/A
N/A
N/A
CONTR
ACTOR
Y
ARCH
ITECT
Y
N/A
N/A
ARCH
ITECT
Y
CONTR
ACTOR
Y
N/A
X
X
X
X
X
X
X
X
X
X
X
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 04/06/2026
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATEOF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
1
6
/
2
0
2
6
2
:
1
8
:
3
3
P
M
G-112
CALIFORNIA GREEN
BUILDING STANDARD
CODE
2510
Au
t
h
o
r
N/A
Y ARCH
ITECT
N/A
N/A
INSPE
CTOR
Y
N/A
CONTR
ACTOR
Y ARCH
ITECT
Y
Y CONTR
ACTOR
X
X
X
X
X
X
X
X
X
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 04/06/2026
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATEOF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
1
6
/
2
0
2
6
2
:
1
8
:
3
6
P
M
G-113
CALIFORNIA GREEN
BUILDING STANDARD
CODE
2510
Au
t
h
o
r
Y ENGI
NEER
Y ENGI
NEER
N/A
N/A
N/A
N/A
CONTR
ACTOR
Y
OWNERY
X
X
X
X
X
X
X
X
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 04/06/2026
OCCUPANCY LEGEND
1006.3.3 EGRESS BASED ON OCCUPANT LOAD
EACH STORY AND OCCUPIED ROOF SHALL HAVE THE MINIMUM NUMBER OF SEPARATE AND DISTINCT
EXITS, OR ACCESS TO EXITS, AS SPECIFIED IN TABLE 1006.3.3. A SINGLE EXIT OR ACCESS TO A SINGLE
EXIT SHALL BE PERMITTED IN ACCORDANCE WITH SECTION 1006.3.4. THE REQUIRED NUMBER OF
EXITS, OR EXIT ACCESS STAIRWAYS OR RAMPS PROVIDING ACCESS TO EXITS, FROM ANY STORY OR
OCCUPIED ROOF SHALL BE MAINTAINED UNTIL ARRIVAL AT THE EXIT DISCHARGE OR A PUBLIC WAY.
1017.2 LIMITATIONS
EXIT ACCESS TRAVEL DISTANCE
SHALL NOT EXCEED THE VALUES
GIVEN IN TABLE 1017.2
1010.1.1 SIZE OF DOORS
THE REQUIRED CAPACITY OF EACH
DOOR OPENING SHALL BE SUFFICIENT
FOR THE OCCUPANT LOAD THEREOF
AND SHALL PROVIDE A MINIMUM
CLEAR OPENING WIDTH OF 32 INCHES
(813 MM). THE CLEAR OPENING WIDTH
OF DOORWAYS WITH SWINGING
DOORS SHALL BE MEASURED
BETWEEN THE FACE OF THE DOOR
AND THE STOP, WITH THE DOOR
OPEN 90 DEGREES (1.57 RAD). WHERE
THIS SECTION REQUIRES A MINIMUM
CLEAR OPENING WIDTH OF 32 INCHES
(813 MM) AND A DOOR OPENING
INCLUDES TWO DOOR LEAVES
WITHOUT A MULLION, ONE LEAF
SHALL PROVIDE A MINIMUM CLEAR
OPENING WIDTH OF 32 INCHES (813
MM).
1005.3.2 OTHER EGRESS
COMPONENTS
THE CAPACITY, IN INCHES, OF MEANS
OF EGRESS COMPONENTS OTHER
THAN STAIRWAYS SHALL BE
CALCULATED BY MULTIPLYING THE
OCCUPANT LOAD SERVED BY SUCH
COMPONENT BY A MEANS OF EGRESS
CAPACITY FACTOR OF 0.2 INCH (5.1
MM) PER OCCUPANT.
1005.3.2 OTHER EGRESS COMPONENTS
THE CAPACITY, IN INCHES, OF MEANS OF EGRESS COMPONENTS OTHER THAN STAIRWAYS SHALL BE
CALCULATED BY MULTIPLYING THE OCCUPANT LOAD SERVED BY SUCH COMPONENT BY A MEANS OF
EGRESS CAPACITY FACTOR OF 0.2 INCH (5.1 MM) PER OCCUPANT.
CODE ANALYSISEGRESS BASED ON OCCUPANT LOAD ACCESS TRAVEL
1-500
501 - 1,000
2
3
4
MINUMUN NUMBER OF EXITS OR
ACCESS TO EXITS FROM STORY
MORE THEN 1,000
OCUPANT LOAD
PER STORY
TABLE 1006.3.3
MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY
TABLE 1017.2
EXIT ACCESS TRAVEL DISTANCEª
A,E,F-1,M,S-1
OCCUPANCY WITHOUT SPRINKLER
SYSTEM (FEET)
WITH SPRINKLER
SYSTEM (FEET)
200e 250b
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
200
300
150
200c
200c
200c
R-2.1
B
F-2, S-2, U
H-1
H-2
H-3
H-4
H-5
I-2, I-2.1, I-3f
I-4
L
TOTAL
OCCUPANTS: 40250b
300b
400b
75b
100b
150b
175b
200b
B BUSINESS A-2 ASSEMBLY NO OCCUPANTS
- EXIT REQUIRED:
OCCUPANT LOAD: 40 OCC
OCCUPANCY: B - BUSINESS / A2 - ASSEMBLY
EXITS REQUIRED (CBC TABLE 1006.3.3): 1
EXIT PROVIDED: 2 (1 EGRESS FROM KITCHEN)
A - HEIGHT OF ACCESSORIES
CBC 11B SECTION 11B-603.5
WHERE TOWEL OR SANITARY NAPKIN DISPENSERS, WASTE RECEPTACLES, OR OTHER ACCESSORIES
ARE PROVIDED IN TOILET FACILITIES, AT LEAST ONE OF EACH TYPE SHALL BE LOCATED ON AN
ACCESSIBLE ROUTE. ALL OPERABLE PARTS, INCLUDING COIN SLOTS, SHALL BE 40 INCHES (1016 MM)
MAXIMUM ABOVE THE FINISH FLOOR.
B - ACCESSIBLE ROUTE TO ACCESSIBLE COMPARTMENT
CBC 11B SECTION 11B-403.5.1 EXCEPTIONS: 5
THE CLEAR WIDTH FOR ACCESSIBLE ROUTES TO ACCESSIBLE TOILET COMPARTMENTS SHALL BE 44
INCHES (1118 MM) EXCEPT FOR DOOR-OPENING WIDTHS AND DOOR SWINGS.
C - STALL WIDTH
CBC 11B SECTION 11B-604.8.1.1
WHEELCHAIR ACCESSIBLE COMPARTMENTS SHALL BE 60 INCHES (1524 MM) WIDE MINIMUM MEASURED
PERPENDICULAR TO THE SIDE WALL, AND 56 INCHES (1422 MM) DEEP MINIMUM FOR WALL HUNG WATER
CLOSETS AND 59 INCHES (1499 MM) DEEP MINIMUM FOR FLOOR MOUNTED WATER CLOSETS MEASURED
PERPENDICULAR TO THE REAR WALL. WHEELCHAIR ACCESSIBLE COMPARTMENTS SHALL ADDITIONALLY
PROVIDE MANEUVERING SPACE COMPLYING WITH SECTION 11B-604.8.1.1.1, 11B-604.8.1.1.2, OR 11B-
604.8.1.1.3, AS APPLICABLE. WHEELCHAIR ACCESSIBLE COMPARTMENTS FOR CHILDREN'S USE SHALL BE
60 INCHES (1524 MM) WIDE MINIMUM MEASURED PERPENDICULAR TO THE SIDE WALL, AND 59 INCHES
(1499 MM) DEEP MINIMUM FOR WALL HUNG AND FLOOR MOUNTED WATER CLOSETS MEASURED
PERPENDICULAR TO THE REAR WALL.
D - ACCESSIBLE STALL DOOR
CBC 11B Section 11B-604.8.1.2
TOILET COMPARTMENT DOORS, INCLUDING DOOR HARDWARE, SHALL COMPLY WITH SECTION 11B-404
EXCEPT THAT IF THE APPROACH IS FROM THE PUSH SIDE OF THE COMPARTMENT DOOR, CLEARANCE
BETWEEN THE DOOR SIDE OF THE COMPARTMENT AND ANY OBSTRUCTION SHALL BE 48 INCHES (1219
MM) MINIMUM MEASURED PERPENDICULAR TO THE COMPARTMENT DOOR IN ITS CLOSED POSITION.
DOORS SHALL BE LOCATED IN THE FRONT PARTITION OR IN THE SIDE WALL OR PARTITION FARTHEST
FROM THE WATER CLOSET. WHERE LOCATED IN THE FRONT PARTITION, THE DOOR OPENING SHALL BE
4 INCHES (102 MM) MAXIMUM FROM THE SIDE WALL OR PARTITION FARTHEST FROM THE WATER
CLOSET. WHERE LOCATED IN THE SIDE WALL OR PARTITION, THE DOOR OPENING HINGE SIDE JAMB FOR
OUT SWINGING DOORS SHALL BE FARTHEST FROM THE WATER CLOSET AND THE STRIKE SIDE JAMB
SHALL BE 54 INCHES (1372 MM) MINIMUM FROM THE REAR WALL. THE DOOR SHALL BE SELF-CLOSING. A
DOOR PULL COMPLYING WITH SECTION 11B-404.2.1 SHALL BE PLACED ON BOTH SIDES OF THE DOOR
NEAR THE LATCH. DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED
FOR ANY FIXTURE. DOORS MAY SWING INTO THAT PORTION OF MANEUVERING SPACE WHICH DOES NOT
OVERLAP THE CLEARANCE REQUIRED AT A WATER CLOSET.
E - STANDING PERSON DRINKING FOUNTAIN
CBC 11B SECTION 11B-602.7
SPOUT OUTLETS OF DRINKING FOUNTAINS FOR STANDING PERSONS SHALL BE 38 INCHES (965 MM)
MINIMUM AND 43 INCHES (1092 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
CBC 11B SECTION 11B-211.2
NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. WHEN PROVIDED, ONE DRINKING
FOUNTAIN SHALL COMPLY WITH SECTIONS 11B-602.1 THROUGH 11 B- 602.6, 11B-602.8 AND 11 B-602.9 AND
ONE DRINKING FOUNTAIN SHALL COMPLY WITH SECTION 11B-602.7 AND 11B-602.9.
F - ENTRY DOOR MANUEVERING CLEARANCE
CBC 11B SECTION 11B-404.2.4.1
SWINGING DOORS AND GATES SHALL HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE
11B-404.2.4.1.
G - CLEARANCE IN FRONT OF TOILET
CBC 11B SECTION 11B-604.3.1
CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES (1524 MM) MINIMUM MEASURED
PERPENDICULAR FROM THE SIDE WALL AND 56 INCHES (1422 MM) MINIMUM MEASURED PERPENDICULAR
FROM THE REAR WALL. A MINIMUM 60 INCHES (1524 MM) WIDE AND 48 INCHES (1219 MM) DEEP
MANEUVERING SPACE SHALL BE PROVIDED IN FRONT OF THE WATER CLOSET.
H - URINAL
CBC 11B SECTION 11B-605.2
URINALS SHALL BE THE STALL-TYPE OR THE WALL-HUNG TYPE WITH THE RIM 17 INCHES (432 MM)
MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. URINALS SHALL BE 13 1/2 INCHES (343 MM) DEEP
MINIMUM MEASURED FROM THE OUTER FACE OF THE URINAL RIM TO THE BACK OF THE FIXTURE.
1210.3.2 URINAL PARTITIONS
EACH URINAL UTILIZED BY THE PUBLIC OR EMPLOYEES SHALL OCCUPY A SEPARATE AREA WITH WALLS
OR PARTITIONS TO PROVIDE PRIVACY. THE WALLS OR PARTITIONS SHALL BEGIN AT A HEIGHT NOT
MORE THAN 12 INCHES (305 MM) FROM AND EXTEND NOT LESS THAN 60 INCHES (1524 MM) ABOVE THE
FINISHED FLOOR SURFACE. THE WALLS OR PARTITIONS SHALL EXTEND FROM THE WALL SURFACE AT
EACH SIDE OF THE URINAL NOT LESS THAN 18 INCHES (457 MM) OR TO A POINT NOT LESS THAN 6
INCHES (152 MM) BEYOND THE OUTERMOST FRONT LIP OF THE URINAL MEASURED FROM THE FINISHED
BACKWALL SURFACE, WHICHEVER IS GREATER.
I - PIPE AT LAVATORIES
CBC 11B SECTION 11B-606.5
WATER SUPPLY AND DRAIN PIPES UNDER LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE
CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES
UNDER LAVATORIES AND SINKS.
J - SIDE GRAB BAR
CBC 11B SECTION 11B-604.5.1
THE SIDE WALL GRAB BAR SHALL BE 42 INCHES (1067 MM) LONG MINIMUM, LOCATED 12 INCHES (305 MM)
MAXIMUM FROM THE REAR WALL AND EXTENDING 54 INCHES (1372 MM) MINIMUM FROM THE REAR WALL
WITH THE FRONT END POSITIONED 24 INCHES (610 MM) MINIMUM IN FRONT OF THE WATER CLOSET.
K - REAR GRAB BAR LENGTH
CBC 11B SECTION 11B-604.5.2
THE REAR WALL GRAB BAR SHALL BE 36 INCHES (914 MM) LONG MINIMUM AND EXTEND FROM THE
CENTERLINE OF THE WATER CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND 24 INCHES
MINIMUM ON THE OTHER SIDE.
L - OPERABLE PARTS (DOOR)
11B-309.4
OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING,
PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL
BE 5 POUNDS (22.2 N) MAXIMUM
2
44" MIN. ACCESSIBLE PATH OF TRAVEL
INDICATES EGRESS ROUTE DIRECTON
EXIT SIGN, SINGLE FACE, W/DIRECTIONAL ARROW AS INDICATED,
MOUNTED ON RECESSED CEILING OUTLET BOX.
EXIT SIGN, DOUBLE FACE, W/DIRECTIONAL ARROWS AS INDICATED,
MOUNTED ON RECESSED CEILING OUTLET BOX
EXIT SIGN, SINGLE FACE, NON DIRECTIONAL ARROW, MOUNTED ON
RECESSED CEILING OUTLET BOX.
62'-5" MAX DIAG.
499 SF
COOK
PREP
539 SF
OPEN
DINING
53 SF
RESTROOM
37 SF
STORAGE
TO
T
A
L
L
E
N
G
T
H
6
8
'
-0"
OCCUPANCY: ASSEMBLY A-2 - (TABLE 422.1 CALIFORNIA PLUMBING CODE)
TOTAL OCCUPANT LOAD: 49 (25 MALE, 25 FEMALE)
PLUMBING FIXTURES REQUIRED (TABLE 422.1 PLUMBING CODE)
REQUIRED WATER
CLOSET URINAL LAVATORIES DRINKING
FOUNTAIN SERVICE SINK
MALE 1 1 1
. .
1 N/A 1FEMALE
CPC 422.1
EXCEPTION (3)
IN BUSINESS AND MERCANTILE OCCUPANCIES WITH A TOTAL OCCUPANT LOAD OF 50 OR LESS INCLUDING
CUSTOMERS AND EMPLOYEES, ONE TOILET FACILITY, DESIGNED FOR USE BY NO MORE THAN ONE
PERSON AT A TIME, SHALL BE PERMITTED FOR USE BY BOTH SEXES.
A-2 ASSEMBLY
OCCUPANCY -
RESTAURANTS,
PUBS, LOUNGES,
NIGHTCLUBS
AND BANQUET
HALLS
Male
1: 1-50
2: 51-150
3: 151-300
4: 301-400
Female
1: 1-25
2: 26-50
3: 51-100
4: 101-200
6: 201-300
8: 301-400
Male
1: 1-200
2: 201-300
3: 301-400
4: 401-600
Male
1: 1-150
2: 151-200
3: 201-400
Female
1: 1-150
2: 151-200
3: 201-400
Over 400, add 1
fixture for each
additional 250 males
and 1 fixture for each
125 females.
Over 600,
add 1 fixture
for each
additional
300 males.
Over 400, add 1 fixture
for each additional 250
males and 1 fixture for
each 200 females.
1: 1-250
2: 251-500
3: 501-750
Over 750, add
1 fixture for
each additional
500 persons.
1 service
sink or
laundry
tray
-
PROVIDED ONE UNISEX RESTROOM IS COMPLIANT TO SERVICE THE EXISTING SQUARE
FOOTAGE AND OCCUPANT LOAD.
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATEOF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
1
6
/
2
0
2
6
2
:
1
8
:
3
7
P
M
G-120
CODE ANALYSIS
2510
Au
t
h
o
r
00 EGRESS LEGEND
EGRESS LEGEND
OCCUPANCY LOAD SCHEDULE
NAME OCC. TYPE AREA DEPARTMENT OCC. LOAD FACTOR
OCC.
LOAD
COOK PREP B 499 SF B - BUSINESS 200 SF 3
OPEN DINING B / A2 539 SF B - BUSINESS 15 SF 36
RESTROOM 53 SF NONE 0 SF
STORAGE S 37 SF STORAGE 150 SF 1
40
1/4" = 1'-0"CODE ANALYSIS PLAN 1
N
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 04/06/2026
3 PLAN RESUBMITTAL 2 04/16/2026
PLUMBING FIXTURE CALCULATIONS
-
2
23
3
SITE ACCESS
GENERAL
ACCESS TO SITE AND ALL BUILDING ENTRANCES AND EXTERIOR GROUND FLOOR EXITS WITHOUT
STEPS OR ABRUPT CHANGES IN LEVEL.
SITE ACCESSIBILITY / SIDEWALKS
• SIGNAGE: ALL PRIMARY PUBLIC SITE ENTRIES AND AT EVERY MAJOR JUNCTION ALONG OR
LEADING TO AN ACCESSIBLE ROUTE, A SIGN DISPLAYING THE INTERNATIONAL SYMBOL OF
ACCESSIBILITY MUST BE POSTED. INDICATE THE DIRECTION TO ACCESSIBLE ENTRANCES AND
FACILITIES
• WIDTH: 4'-0"
• MAXIMUM CROSS SLOPE: 1:50 (2%)
• MAXIMUM SLOPE: 1:20 (5%)
• LANDINGS: PROVIDE 5'-0" LONG LANDINGS A MINIMUM OF EVERY 400 FEET AT SIDEWALKS WITH
CONTINUOUS SLOPES.
• CURB CUT WIDTH: 4'-0"
• NO CHANGE IN LEVEL EXCEEDING ½ INCH.
RAMPS
• MAXIMUM SLOPE: 1:12
• INTERMEDIATE RAMP LANDINGS EVERY 2.5 FEET, OF VERTICAL RISE WITH LENGTH DEPENDENT
UPON SLOPE.
• HANDRAILS REQUIRED: FOR SLOPES EXCEEDING 1:20 WHEEL GUIDE RAILS OR 2" CURBS ARE
REQUIRED WHEN RAMP IS NOT BOUNDED BY WALL FENCE OR RAMP EXCEEDS 10'-0” IN LENGTH.
PARKING
• WIDTH: 9'-0"
• LENGTH: 18'-0"
• MAXIMUM SLOPE SPACE: ¼ INCH PER FOOT. ADJACENT CLEAR LOADING AND UNLOADING
WIDTH FOR ACCESSIBLE PARKING SPACE: 5'-0" ADJACENT CLEAR LOADING AND UNLOADING
WIDTH FOR VAN: 8'-0" AND LOCATED ON PASSENGER SIDE OF STALL WHEELCHAIR ACCESS
PROVIDED TO WALKS WITHOUT GOING BEHIND PARKED CARS.
SIGNAGE
• PROVIDE SIGNS AT ACCESSIBLE PARKING SPACE. SIGNS PROVIDED TO INDICATE ACCESSIBLE
ENTRIES AT EXISTING BUILDINGS WHERE NOT THE PRIMARY ENTRY.
• EACH PARKING SPACE RESERVED FOR PERSONS WITH DISABILITIES SHALL BE IDENTIFIED BY
REFLECTORIZED SIGN PERMANENTLY POSED IMMEDIATELY ADJACENT TO AND VISIBLE FROM
EACH STALL OR SPACE, CONSISTING OF A PROFILE VIEW OF A WHEELCHAIR WITH OCCUPANT IN
WHITE ON DARK BLUE BACKGROUND. THE SIGN SHALL NOT BE SMALLER THAN 70 SQUARE
INCHES IN AREAS AND, WHEN IN A PATH OF TRAVEL, SHALL BE POSTED AT A MINIMUM HEIGHT
OF 80" FROM THE BOTTOM OF THE SIGN TO THE PARKING SPACE FINISHED GRADE. SIGNS MAY
ALSO BE CENTERED ON THE WALL AT THE INTERIOR END OF THE PARKING SPACE. AN
ADDITIONAL SIGN OR ADDITIONAL LANGUAGE BELOW THE SYMBOL OF ACCESSIBILITY SHALL
STATE "MINIMUM FINE $250." (FIG. A & B ABOVE). (CBC 1109A8.8) (CBC 11B-502.6.2)
• VAN ACCESSIBLE PARKING SPACES SHALL HAVE AN ADDITIONAL SIGN STATE "VAN-ACCESSIBLE"
MOUNTED BELOW THE SYMBOL OF ACCESSIBILITY. AND SIGN SHALL BE 60" ABOVE FINISH
FLOOR (CBC 11B-502.6)
• ADDITIONAL SIGN SHALL ALSO BE POSTED, IN A CONSPICUOUS PLACE, AT EACH ENTRANCE TO
OFF-STREET PARKING FACILITIES, OR IMMEDIATELY ADJACENT TO AND VISIBLE FROM EACH
STALL OR SPACE. THE SIGN SHALL BE NOT LESS THAN 17" BY 22" IN SIZE WITH LETTERING NOT
LESS THAN 1" IN HEIGHT. (SEE FIG. ABOVE) (CBC 1109A.8.8 AND 11B-502.8.2)
• THE SURFACE OF EACH ACCESSIBLE PARKING SPACE OR STALL SHALL HAVE A SURFACE
IDENTIFICATION DUPLICATING EITHER OF THE FOLLOWING SCHEMES:
a. BY OUTLINING OR PAINTING THE STALL OR SPACE IN BLUE AND OUTLINING ON THE GROUND
IN STALL OR SPACE IN WHITE OR SUITABLE CONTRASTING COLOR A PROFILE VIEW DEPICTING
WHEELCHAIR WITH OCCUPANT;
OR
b. BY OUTLINING A PROFILE VIEW OF A WHEELCHAIR WITH OCCUPANT IN WHITE ON BLUE
BACKGROUND. THE PROFILE VIEW SHALL BE LOCATED SO THAT IT IS VISIBLE TO A TRAFFIC
ENFORCEMENT OFFICER WHEN A VEHICLE IS PROPERLY PARKED IN THE SPACE AND SHALL BE
36" HIGH BY 36" WIDE. (CBC 11B-502.6.4)
HANDRAILS
• HANDRAILS REQUIRED AT WALKING SUFACES COMPLYING WITH CBC 11B-403, RAMPS
COMPLYING WITH CBC 11B-405 AND STAIRS COMPLYING WITH CBC 11B-504.
• HANDRAILS SHALL BE PROVIDED ON BOTH SIDES OF STAIRS AND RAMPS.
• HANDRAILS SHALL BE CONTINUOUS.
• TOP OF GRIPPING SURFACE SHALL BE 34" MIN -38" MAX. ABOVE WALKING SURFACE, STAIN
NOSING AND RAMP SURFACES. HEIGHT SHALL BE CONSISTENT.
• CLEARANCE BETWEEN HANDRAIL GRIPPING SURFACES AND ADJACENT SURFACE SHALL BE
1-1/2" MIN.
• GRIPPING SURFACE SHALL BE CONTINUOUS ALONG THEIR LENGTH AND SHALL NOT BE
OBSTRUCTED ALONG THEIR TOPS OR SIDES.
NO
PARKING
23' - 0" MIN.
PEDESTRIAN ROUTE
ACCESSIBILITY SIGN PER LOCAL CODES
WHEEL STOP
WITHIN THE LOADING AND LANDING ACCESS AISLE PAINT THE
WORDS "NO PARKING" IN WHITE 12" HIGH LETTERS
TYPICAL PAVEMENT SYMBOL PER LOCAL CODES
CAR
3'-0" X 3'-0" INTERNATIONAL SYMBOL OF ACCESSIBILITY
SEE DETAIL
TYPICAL PAVEMENT SYMBOL PER LOCAL CODES
BLUE BORDER ACCESS AISLE
CAR
CBC SECTION 11B-502.3
2% MAX. SLOPE @ ACCESSIBLE
SPACES IN ANY DIRECTION
60"
21
6
"
M
I
N
/6 G-140
/7 G-140
/4 G-140PARKING SIGN SHALL READ:
"UNAUTHORIZED VEHICLES PARKED
IN DESIGNATED ACCESSIBLE SPACES
NOT DISPLAYING DISTINGUISHING
PLACARDS OR SPECIAL LICENSE
PLATES ISSUED FOR PERSONS WITH
DISABILITIES WILL BE TOWED AWAY
AT THE OWNER'S EXPENSE.
TOWED VEHICLES MAY BE CLAIMED
AT (INSERT ADDRESS) OR BY
TELEPHONING (INSERT TELEPHONE
NUMBER)". ALL LETTERING SHALL BE
A MINUMUM OF 1" IN HEIGHT. USE
R100B (CA) SIGN.
APPROPRIATE INFORMATION
SHALL BE ADDED TO SIGN.
FINISH GRADE / PAVEMENT
CONCRETE FOOTING
2" X 3" X 3/16" GALV. STEEL TUBE
AND PAINTED, CAP TUBE END.
EQ
7'
-
0
"
MI
N
2' - 0"
4"
1'
-
2
"
6"
1' - 0"
CBC SECTION 11B-502.8.2
PRE-MANUFACTURED SIGN TO
COMPLY W/ THE MANUAL OF
UNIFORM TRAFFIC CONTROL
DEVICES STANDARD,
R99C (CA) SIGN.
PROVIDE VAN ACCESSIBLE
INSCRUPTION @ VAN STALL
LOCATIONS. USE R7-8b SIGN.
SUPPORT STANDARD 3" DIA. GALV.
STEEL POLE W/ 2'-0" IMBEDMENT
ATTACH SIGN TO POLE W/ GALV.
STRAPS AT TOP & BOTTOM.
HEIGHT WHEN LOCATED IN PATH
OF TRAVEL; 36" MIN. FOR WALL-
MOUNTED
H.C. VAN
12"
24
"
6
"
84
"
MI
N
PRE-MANUFACTURED SIGN TO
COMPLY W/ THE MANUAL OF
UNIFORM TRAFFIC CONTROL
DEVICES STANDARD,
R99C (CA) SIGN.
SUPPORT STANDARD 3" DIA. GALV.
STEEL POLE W/ 2'-0" IMBEDMENT
ATTACH SIGN TO POLE W/ GALV.
STRAPS AT TOP & BOTTOM.
HEIGHT WHEN LOCATED IN PATH
OF TRAVEL; 36" MIN. FOR WALL-
MOUNTED
H.C. SIGNAGE
12"
24
"
84
"
MI
N
SIGNAGE
CBC SECTION 11B-502.6
NO
PARKING
26' - 0" MIN.
21
6
"
M
I
N
.
PEDESTRIAN ROUTE
ACCESSIBILITY SIGN PER LOCAL CODES
WHEEL STOP PER DETAIL
WITHIN THE LOADING AND LANDING ACCESS AISLE PAINT THE
WORDS "NO PARKING" IN WHITE 12" HIGH LETTERS
TYPICAL PAVEMENT SYMBOL PER LOCAL CODES
VAN CAR
3'-0" X 3'-0" INTERNATIONAL SYMBOL OF ACCESSIBILITY,
SEE
TYPICAL PAVEMENT SYMBOL PER LOCAL CODES
BLUE BORDER
CBC SECTION 11B-502.2
2% MAX. SLOPE @ ACCESSIBLE
SPACES IN ANY DIRECTION
144" MIN 60" 108" MIN
Ref
AL
I
G
N
W
/
E
N
D
O
F
P
A
R
K
I
N
G
S
T
R
I
P
I
N
G
CALTRANS STANDARD , A24 C
CBC SECTION 11B-502.6.4.1
BLUE
WHITE
36"
36
"
CBC SECTION 502.7.2
5/8" DIA. DRILLED HOLES, FILL
FLUSH W/ ELASTOMERIC
SEALANT
7 1/2"
2 1/2"2 1/2"2 1/2"
4'-0 - 8'-0" (L) PRECAST
CONCRETE WHEELSTOP
8"
6"
3"
2-#3 BARS (3" )
PAVEMENT
2-#4 @ 8" FROM END AND
3'-4" MAX. O.C. - 18" LONG,
FLUSH WITH TOP OF
WHEEL STOP
WALL OR OTHER OBSTRUCTION
NOTE: CROSS SLOPE OF
LANDING AREA DOES NOT
EXCEED 1:48 (2.08%) IN ANY
DIRECTION
1:48 (2.08%) MAX.
8.33% MAX.
48" M
I
N.
48" MIN.
12"
10% MAX.
101
GROOVED BORDER MUST BE
ON THE LEVEL SURFACE AT
THE TOP OF RAMP
NOTE: TRUNCATED DOME DETECTABLE WARNING SURFACE IS REQUIRED ON SHADED
PORTION OF RAMP.
36"
TRUNCATED DOMES
CBC 11B-406.5.3
LEVEL
LANDING
LEVEL
LANDING
SLOPE MAXIMUM RISE MAXIMUM HORIZONTAL
PROJECTION
1:12 (8.33%)
1:16 (6.25%)
30"
30"
30'-0"
40'-0"
CBC 2022 1114A.4.1
OR RUN
HORIZONAL PROJECTION
SURFACE OF RAMP
RI
S
E
1:15 (6.67%) 30" 37'-6"
1:20 (5.00%) 30" 50'-0"
1-1/2" DIA. PAINTED MTL. PIPE
RAILING W/CLOSED EXPOSED
END
GALV. SLEEVE OR CORE HOLE FOR
POST. 6" EMBED AND EXPOXY W/
HILTI HIT RE 500-SD TYP.
SEALANT ALL ROUND, TYP.
CONC. RAMP OR LANDING PER CIVIL
34
"
-
3
8
"
2"
GRADE
12"
34
"
-
3
8
"
12"
THREAD
12" PLUS (X)
(THREAD)
X
34
"
-
3
8
"
BOTTOM HANDRAIL EXTENSION AT STAIRS
CBC SECTION 11B-505.10.3
TOP HANDRAIL EXTENSION AT STAIRS
CBC SECTION 11B-505.10.2
WALKING SURFACES
CBC SECTION 11B-505.4
RAMPS
34
"
-
3
8
"
34"-38"
INCLUDING HANDRAIL
48" MIN
4"
.
3
6
"
.
GUARDRAIL REQUIRED
IF MORE THAN 4"CLEAR WIDTH AT RAMP
CBC 11B-405.5
LEVEL
LANDING
12" MIN
LEVEL
LANDING
<2
7
"
34
"
-
3
8
"
12" MIN
1:12 MAX SLOPE HANDRAIL
72" MIN
60" MIN WHEN NO LANDING
DOOR SWINGS ONTO LANDING
60
"
M
I
N
GUIDED RAIL AT
3" ± 1" HIGH
TOP
LANDING
42"MIN. PLUS THE
DOOR WIDTH WHEN
DOOR SWINGS ONTO
LANDING
BOTTOM
LANDING REQUIRED IF SLOPE EXCEEDS 1:20
WIDTH MUST BE OF
60" WITH OCCUPANCY
OF 300 OR MORE
.
LESS
THAN 4"
RAMP
CBC 11B-405 & 11B-405.7
2
1
1/
4
"
MA
X
CHANGE IN LEVEL
CBC FIGURE 11B-303.2
1/
4
"
.
1/
4
"
.1/
2
"
.
RAILING AT RAMP
CBC FIGURE 11B-505.10.1
BEVELED CHANGE IN LEVEL
CBC 11B-303.3
2.3 - 2.4 MIN
2.
3
-
2
.
4
0.45"-
2.3" - 2.4"
R=0.4
1
3
"
0.65 MIN
PLAN ELEVATION
SPACING OF TRUNCATED DOMES
CBC 11B-705.1
NOTES:
1. MATERIAL USED SHALL BE OF YELLOW, CONFORMING TO FS33538 OF SAE AMSSTD-595A AND
SHALL BE OF INTEGRAL PART OF THE WALKING SURFACE.
2. WARNING SURFACE TO BE FIRM AND SLIP RESISTANT, MAY INCLUDE, BUT NOT LIMITED TO THE
FOLLOWING SURFACES: NATURAL STONE OR STONE COMPOSITE, CERAMIC TILE, DURABLE
PRECAST CONCRTE SCALES, RIGID OR FLEXIBLE COMPOSITES.
3. FASTEN ALL SURAFACES MOUNTED APPLICATIONS IN STRICT ACCORDANCE WITH
MANUFACTURER SPECIFICATIONS.
4. REFER TO CALIFORNIA BUILDING CODE SECTION 705 FOR SPECIFICATIONS AND
INSTALLATIONS DETAILS. VERTICAL TRANSITIONS DUE TO INSTALLATION TO COMPLY WITH ALL
APPLICABLE CALIFORNIA BUILDING CODE SPECIFICATIONS.
CBC SECTION 502.7.2
PRE-CAST CONCRETE
WHEEL STOP
3' - 0"
6.
5
"
M
A
X
6"
7
1
/
2
"
2'
-
4
"
1' - 0"
OR REFER TO EXISTING WHEELSTOP TO MATCH
3' - 0"
CONCRETE WHEEL STOP
CENTERLINE AT PARKING
STALL. SEE SITE PLAN
FOR WHICH END WHEEL
STOP IS TO OCCUR
REBAR
CL
CONCRETE CURB
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATEOF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
1
6
/
2
0
2
6
2
:
1
8
:
3
8
P
M
G-140
ADA SITE AND PARKING
DETAILS
2510
Au
t
h
o
r
SITE ACCESS NOTES
1/4" = 1'-0"ACCESSIBLE PARKING SPACE -VAN 53/4" = 1'-0"ACCESSIBLE SYMBOL 6
1/4" = 1'-0"ACCESSIBLE PARKING SPACES 11" = 1'-0"PARKING SIGN DETAIL 2
1 1/2" =
1'-0"CURB DETAIL 8
1/4" = 1'-0"RAMP/PROJECTIONS OF HANDRAILS 131 1/2" =
1'-0"HANDRAIL DETAIL 10 1/2" = 1'-0"HANDRAIL HEIGHT 12
1/2" = 1'-0"HANDRAIL EXTENSION STAIR 11
3" = 1'-0"CONCRETE WHEEL STOP DETAIL 7
1" = 1'-0"WHEEL STOP 15 1 1/2" =
1'-0"ACCESSIBLE PARKING SIGNAGE 4
6" = 1'-0"TRUNCATED DOME DETAIL 14 1/4" = 1'-0"RAMP/PROJECTIONS OF HANDRAILS 9
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 04/06/2026
STORAGE FACILITIES & AREAS
• IF FIXED STORAGE FACILITIES SUCH AS CABINETS, SHELVES, CLOSETS, OR DRAWERS ARE
PROVIDED WHERE ACCESS IS REQUIRED BY CBC 11B-308 LEAST ONE OF EACH TYPE SHALL BE
ACCESSIBLE IN TERMS OF CLEAR SPACE, REACH RANGES, AND HARDWARE. ADDITIONAL
STORAGE MAY BE PROVIDED OUTSIDE OF REQUIRED REACH RANGES.
• A CLEAR FLOOR SPACE AT LEAST 30" BY 48" THAT ALLOWS EITHER A FORWARD OR PARALLEL
APPROACH BY A PERSON USING A WHEELCHAIR SHALL BE PROVIDED AT ACCESSIBLE
STORAGE FACILITIES. (CBC 11B-305.3)
• ACCESSIBLE STORAGE SPACES SHALL BE WITHIN AT LEAST ONE OF THE HEIGHT RANGES
SPECIFIED IN CBC 11B-308.2 AND CBC 11B-308.3)
• HARDWARE FOR ACCESSIBLE STORAGE FACILITIES SHALL COMPLY WITH CBC 11B-305 FOR
CLEAR FLOOR SPACE AND CBC 11B-308 FOR HEIGHTS.
• OPERABLE PARTS SHALL BE OPERABLE WITH ON HAND AND SHALL NOT REQUIRE TIGHT
GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE
OPERABLE PARTS SHALL BE 5 POUNDS (22.2 N) MAX.
• THE DOORWAY PROVIDING ACCESS TO STORAGE AREAS SHALL BE NOT LESS THAN 32" IN
CLEAR WIDTH. (CBC 11B-404.2.3) STORAGE AREAS SHALL BE MADE ACCESSIBLE AS REQUIRED.
DRINKING FOUNTAIN
• UNITS SHALL HAVE A CLEAR FLOOR SPACE OR GROUND SPACE POSITIONED FOR A FORWARD
APPROACH AND CENTERED ON THE UNIT COMPLYING WITH CBC 11B-305.
• OPERABLE PARTS SHALL COMPLY WITH SECTION 11B-309. THE FLOW OF WATER SHALL BE
ACTIVATED BY A MANUALLY OPERATED SYSTEM THAT IS FRONT MOUNTED OR SIDE MOUNTED
AND LOCATED WITHIN 6 INCHES OF THE FRONT EDGE OF THE FOUNTAIN OR AN AUTOMATIC
ELECTRONICALLY CONTROLLED DEVICE.
• SPOUT OUTLETS SHALL BE 36" MAXIMUM ABOVE THE FINISHED FLOOR
• THE SPOUT SHALL BE LOCATED 15 INCHES MINIMUM FROM THE VERTICAL SUPPORT AND 5
INCHES MAXIMUM FROM THE FRONT EDGE OF THE UNIT BUMPERS.
DRINKING FOUNTAINS FOR STANDING PERSON
• SPOUT OUTLETS OF DRINKING FOUNTAINS FOR STANDING PERSONS : 38" MIN - 43"MAX ABOVE
F.F.L.
• WALL AND POST MOUNTED CANTILEVERED DRINKING FOUNTAINS SHALL BE 18" MINIMUM AND
19" MAXIMUM IN DEPTH.
• ALL DRINKING FOUNTAINS SHALL EITHER BE LOCATED COMPLETELY WITHIN ALCOVES,
POSITIONED COMPLETELY BETWEEN WING WALLS, OR OTHERWISE POSITIONED SO AS NOT TO
ENCROACH INTO PEDESTRIAN WAYS. THE
• PROTECTED AREA WITHIN WHICH A DRINKING FOUNTAIN IS LOCATED SHALL BE 32" WIDE
MINIMUM AND 18" DEEP MINIMUM AND SHALL COMPLY WITH SECTION 11B-305.7. WHEN USED,
WING WALL SO BARRIERS SHALL PROJECT HORIZONTALLY AT LEAST AS FAR AS THE DRINKING
FOUNTAIN AND TO WITHIN 6" VERTICALLY FROM THE FLOOR OR GROUND SURFACE.
1. CONTROLS AND OPERATING MECHANISMS REQUIRED TO BE ACCESSIBLE SHALL COMPLY WITH
THE REQUIREMENTS OF SECTION 11B-309
2. CLEAR FLOOR SPACE COMPLYING WITH SECTION 11B-305 THAT ALLOWS A FORWARD OR
PARALLEL APPROACH BY A PERSON USING A WHEELCHAIR SHALL BE PROVIDED AT CONTROLS,
DISPENSERS, RECEPTACLES, AND OTHER OPERABLE EQUIPMENT.
3. THE HIGHEST AND LOWEST OPERABLE PART OF ALL CONTROLS, DISPENSERS, RECEPTACLES,
AND OTHER OPERABLE EQUIPMENT SHALL BE PLACED WITHIN 48" OF THE FLOOR BUT NOT LOWER
THAN 15" IF FORWARD APPROACHED AND WITHIN 48" BUT NOT LOWER THAN 15" IF SIDE
APPROACHED. ELECTRICAL AND COMMUNICATION SYSTEM RECEPTACLES ON WALLS SHALL BE
MOUNTED NO LESS THAN 15" ABOVE THE FLOOR TO THE BOTTOM OF THE OUTLET BOX.
4. CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH THE ONE HAND AND
SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE
REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS OF FORCE PER
SECTION 11B-309.4.
5. THE BOTTOM OF THE OUTLET BOX OF RECEPTACLE OUTLETS SHALL BE NOT LESS THAN 15
INCHES ABOVE THE FLOOR OR WORKING PLATFORM.
6. THE TOP OF THE OUTLET BOX OF SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE
ROOM OR AREA TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES, OR COOLING,
HEATING AND VENTILATING EQUIPMENT SHALL NOT BE MORE THAN 4- FEET ABOVE THE FLOOR OR
WORKING PLATFORM.
7. PER SECTION 907.4.2.2, THE HEIGHT OF THE MANUAL FIRE ALARM BOXES SHALL BE 42"-48" TO
THE HIGHEST POINT OF ACTIVATING HANDLE.
STORAGE
DRINKING FOUNTAIN
CONTROL OPERATING MECHANISM
FIGURE 11B-604.5.2
REAR WALL GRAB BAR AT
WATER CLOSET
FIGURE 11B-604.5.1
SIDE WALL GRAB BAR AT
WATER CLOSET
TRANSFER SIDE
36" MIN.
12" MIN.24" MIN.
17
"
-
1
9
"
2'-0" MIN.
MIN.
42"12" MAX.
54" MIN.
MANUEVERING SPACE
48" MIN
WATER CLOSET
59" MIN @ FLOOR MOUNTED
60
"
M
I
N
WATER CLOSET
56" MIN @ WALL MOUNTED
FIGURE 11B-604.8.1.1.3
MANUEVERING SPACE WITH END-OPENING DOOR
MANUEVERING SPACE
48" MIN
WATER CLOSET
59" MIN @ FLOOR MOUNTED
60
"
M
I
N
4"
WATER CLOSET
56" MIN @ WALL MOUNTED 36"
OUT SWINGING DOORIN-SWINGING DOOR
CH
I
L
D
R
E
N
12
"
M
I
N
MIN
6"
PARTITION
ELEVATION
AD
U
L
T
9"
M
I
N
FIGURE 11B-604.8.1.4
WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT
TOE CLEARANCE
CLEAR KNEE SPACE
WALL MOUNTED LAVATORY
17" MIN.
27
"
M
I
N
.
34
"
M
A
X
.
29
"
M
I
N
.
9"
M
I
N
.
6" MAX.8" MIN.
KNEE CLEARANCE
OF
M
I
R
R
O
R
34
"
M
A
X
.
T
O
B
O
T
T
O
M
LIGHT SWITCH
THERMOSTAT
RECESSED SEAT COVER &
TISSUE DISPENSER AND / OR
NAPKIN DISPOSAL
GRAB BAR
PROTRUSION 14"
MIN. OUTWARD
INSULATE HOT WATER & DRAIN PIPES
OPERATING
DEVICE HEIGHT
MIRROR - 40" MAX.TO BOTTOM EDGE OF
REFLECING SURFACE
SOAP DISPENSER
PAPER TOWEL
DISPENSER
44
"
M
A
X
.
40
"
33
"
19
"
M
A
X
.
17
"
M
I
N
.
17
"
M
A
X
.
R
I
M
H
E
I
G
H
T
LAVATORYURINAL
FRONT SIDE
MA
X
.
34
"
MI
N
.
27
"
OUTLET
BO
T
.
F
I
X
T
.
15
"
M
I
N
.
48
"
ELECTRICAL
1' - 6"
MIN.
1' - 0"
MIN.
2' - 0"
19
"
M
I
N
.
WATER CLOSETHAND
DRYER
TOWELS
& TRASH
WASTETELSANITARY
NAPKINS
CUPS
3' - 6"
CBC
FIGURE 11B-604.8.1.4
MA
X
.
3'
-
4
"
1'
-
0
"
4'
-
1
0
"
TYPICAL
PARTITION
CBC
FIGURE 11B-604.8.14
CBC
FIGURE 11B-604.5.1-.5.2
11B-604.7.1.-7.2
7"-9"
CBC
FIGURE 11B-605.2
ACCESSORIES - WHERE TOWEL OR SANITARY NAPKIN DISPENSERS, WASTE RECEPTACLES, OR OTHER ACCESSORIES
ARE PROVIDED IN TOILET FACILITIES, AT LEAST ONE OF EACH TYPE SHALL BE LOCATED ON AN ACCESSIBLE ROUTE.
ALL OPERABLE PARTS, INCLUDING COIN SLOTS, SHALL BE 40 INCHES (1016 MM) MAXIMUM ABOVE THE FINISH
FLOOR.CBC 2022 FIGURE 11B-603.5
1. SANITARY FACILITIES THAT SERVE BUILDINGS, FACILITIES OR PORTIONS OF BUILDINGS OR
FACILITIES THAT ARE REQUIRED TO BE ACCESSIBLE TO PERSONS WITH DISABILITIES ARE
REQUIRED TO BE ACCESSIBLE. (CBC 11B-601)
2. WHERE SEPARATE FACILITIES ARE PROVIDED FOR NON-DISABLE PERSONS FOR EACH SEX,
SEPARATE FACILITIES SHALL BE PROVIDED FOR PERSONS W ITH DISABILITIES OF EACH SEX ALSO.
WHERE UNISEX FACILITIES ARE PROVIDED FOR NON-HANDICAPPED/NON-DISABLED PERSONS,
SUCH UNISEX FACILITIES CAN BE PROVIDED FOR PERSONS WITH DISABILITIES.
3. DOORWAYS LEADING TO MEN'S SANITARY FACILITIES SHALL BE IDENTIFIED BY AN EQUILATERAL
TRIANGLE 1/4" THICK WITH EDGES 12" LONG AND A VERTEX POINTING UPWARD. WOMEN'S
SANITARY FACILITIES SHALL BE IDENTIFIED BY A CIRCLE 1/4" THICK AND 12" IN DIAMETER.(CBC
11B-703.7.2.6 AND 11B-703.7.2.6.2)
4. UNISEX SANITARY FACILITIES SHALL BE IDENTIFIED BY A CIRCLE 1/4" THICK, 12" IN DIAMETER,WITH
A 1/4" THICK TRIANGLE SUPERIMPOSED ON THE CIRCLE AND WITHIN THE 12" DIAMETER. (CBC
11B-703.7.2.6.3)
5. GEOMETRIC (CIRCLE AND TRIANGLE) SYMBOLS ON SANITARY DOORS SHALL BE CENTERED ON THE
DOOR AT A HEIGHT OF 58" MIN TO 60" MAX ABOVE FINISH FLOOR AND THEIR COLOR AND
CONTRAST SHALL BE DISTINCTLY DIFFERENT FROM THE COLOR AND CONTRAST OF THE DOOR.
(CBC 11B-703.7.2.6)
6. THE HEIGHT OF ACCESSIBLE WATER CLOSETS SHALL BE A MINIMUM OF 17" AND A MAXIMUM OF 19"
MEASURED TO THE TOP OF A MAXIMUM 2" HIGH TOILET SEAT, EXCEPT THAT 3" SEATS SHALL BE
PERMITTED ONLY IN ALTERATIONS WHERE THE EXISTING FIXTURE IS LESS THAN 15" HIGH. (CBC
11B-604.4)
7. A CLEAR FLOOR SPACE 30" BY 48" SHALL BE PROVIDED IN FRONT OF A LAVATORY TO ALLOW A
FORWARD APPROACH. SUCH CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP AN ACCESSIBLE
ROUTE AND SHALL EXTEND INTO KNEE AND TOE SPACE UNDERNEATH THE LAVATORY. (CBC
11B-305)
8. LAVATORIES ADJACENT TO A WALL SHALL BE MOUNTED WITH A MINIMUM DISTANCE OF 18" TO THE
CENTERLINE OF THE FIXTURE. (CBC 11B-606.6)
9. LAVATORIES SHALL BE MOUNTED WITH THE RIM OR COUNTER SURFACE NO HIGHER THAN 34"
ABOVE THE FINISHED FLOOR AND WITH A CLEARANCE OF AT LEAST 29" FROM THE FLOOR TO THE
BOTTOM OF THE APRON WITH KNEE CLEARANCE UNDER THE FRONT LIP EXTENDING A MINIMUM OF
30" IN WIDTH AND 8" MINIMUM DEPTH AT THE TOP. TOE CLEARANCE SHALL BE THE SAME WIDTH
AND SHALL BE A MINIMUM OF 9" HIGH FROM THE FLOOR AND A MINIMUM OF 17" DEEP FROM THE
FRONT OF THE LAVATORY. (CBC 11B-606.2 AND 11B-606.3)
10. HOT WATER AND DRAIN PIPES ACCESSIBLE UNDER LAVATORIES SHALL BE INSULATED OR
OTHERWISE COVERED. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER
LAVATORIES. (CBC 11B-606.5)
11. WHERE URINALS ARE PROVIDED, AT LEAST ONE SHALL HAVE A CLEAR FLOOR SPACE 30" BY 48" IN
FRONT OF THE URINAL TO ALLOW FORWARD APPROACH. (CBC 11B-605.3)
12. CONTROLS FOR WATER CLOSET FLUSH VALVES SHALL BE MOUNTED ON THE OPEN SIDE THE
WATER CLOSET AREA EXCEPT IN AMBULATORY ACCESSIBLE COMPARTMENTS COMPLYING WITH
SECTION 11B-604.8.2. (CBC 11B-604.6)
13. WATER CLOSET AND URINAL FLUSH VALVE CONTROLS, AND FAUCET AND OPERATING MECHANISM
CONTROLS, SHALL BE OPERABLE WITH ONE HAND, SHALL NOT REQUIRE TIGHT GRASPING,
PINCHING, OR TWISTING OF THE WRIST, AND SHALL BE MOUNTED NO MORE THAN 44" ABOVE THE
FLOOR. (CBC 11B-606.4) (CBC 11B-604.9.5) (CBC 11B-605.4)
14. THE FORCE REQUIRED TO ACTIVATE WATER CLOSET AND URINAL FLUSH VALVE CONTROLS, AND
FAUCET AND OPERATING MECHANISM CONTROLS, SHALL BE NO GREATER THAN 5 LBF.
15. SELF-CLOSING FAUCET CONTROL VALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT
LEAST TEN SECONDS.
16. MIRRORS SHALL BE MOUNTED WITH THE BOTTOM EDGE NO HIGHER THAN 40" FROM THE FLOOR.
(CBC 11B-603.3)
17. WHERE TOWEL, SANITARY NAPKINS, WASTE RECEPTACLES, AND OTHER SIMILAR DISPENSING AND
DISPOSAL FIXTURES ARE PROVIDED, AT LEAST ONE OF EACH TYPE SHALL BE LOCATED WITH ALL
OPERABLE PARTS, INCLUDING COIN SLOTS, WITHIN 40" FROM THE FINISHED FLOOR. (CBC
11B-603.5)
18. TOILET TISSUES DISPENSERS SHALL BE 7" MIN AND 9" MAX IN FRONT OF WATER CLOSET. THE
OUTLET OF THE DISPENSER SHALL BE BELOW THE GRAB BAR AND 19" MIN ABOVE FINISH FLOOR.
DISPENSERS THAT CONTROL DELIVERY OR THAT DO NOT PERMIT CONTINUOUS PAPER FLOW
SHALL NOT BE USED. (CBC 11B-604.7)
19. WATER CLOSET SEATS, FOR PUBLIC USE, SHALL BE ELONGATED TYPE AND EITHER OF THE OPEN
FRONT TYPE OR HAVE AN AUTOMATIC SEAT COVER DISPENSER (CPC 411.1 & 411.3)
20. ALL LAVATORIES THAT ARE DESIGNATED TO BE ACCESSIBLE SHALL BE MOUNTED WITH THE RIM
OR COUNTER EDGE NO HIGHER THAN 34" ABOVE THE FINISHED FLOOR AND WITH A VERTICAL
CLEARANCE MEASURED FROM THE BOTTOM OF THE APRON OR OUTSIDE BOTTOM EDGE OF THE
LAVATORY OF 29", REDUCING TO 27" AT A POINT LOCATED 8" BACK FROM THE FRONT EDGE. KNEE
CLEARANCE BELOW THE LAVATORY SHALL EXTEND A MINIMUM OF 30" IN WIDTH BY 17" IN DEPTH.
TOE CLEARANCE SHALL BE THE SAME WIDTH AND SHALL BE A MINIMUM OF 9" HIGH FROM THE
FLOOR AND A MINIMUM OF 17" DEEP FROM THE FRONT OF THE LAVATORY.
21. TOILET ROOM FLOORS SHALL HAVE A SMOOTH, HARD, NON-ABSORBENT SURFACE SUCH AS
PORTLAND CEMENT, CONCRETE, CERAMIC TILE OR OTHER APPROVED MATERIAL WHICH EXTENDS
UPWARD ONTO THE WALLS AT LEAST 5". WALLS WITHIN WATER CLOSET COMPARTMENT AND
WALLS WITHIN 24" OF THE FRONT AND SIDES IF URINALS SHALL BE SIMILARLY FINISHED TO A
HEIGHT OR 48" AND, EXCEPT FOR STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS
SHALL BE A TYPE WHICH IS NOT ADVERSELY AFFECTED BY MOISTURE.
MULTIPLE ACCOMMODATION TOILETS
• ENTRANCE DOOR TO ROOM: 2'-8" CLEAR (3'-0" DOOR).
• SPACE AT DOOR SWING SIDE: 5'-0" x 5'-0"
• SPACE AT DOOR AWAY FROM SWING: 3'-8"
• WHEELCHAIR TURNING SPACE PROVIDED: 5'-0" DIAMETER
• ACCESSIBLE PATH TO ACCESSIBLE TOILET COMPARTMENT: 3'-8" (44")
URINALS (WHERE REQUIRED)
• PROVIDE AT LEAST ONE, AT NOT MORE THAN 1'-5" FROM THE FLOOR TO LIP, WITH FLUSH HANDLER
SET AT +44" ABOVE FLOOR. RIM TO PROJECT A MINIMUM OF 13 1/2" FROM WALL.
• WHERE URINALS ARE PROVIDED, AT LEAST ONE SHALL HAVE A CLEAR FLOOR SPACE 30" BY 48" IN
FRONT OF THE URINAL TO ALLOW FORWARD APPROACH. (CBC 11B-605.3)
LAVATORIES (CBC 11B-305)
• HEIGHT: 34" MAX.
• CLEAR SPACE IN FRONT: 2'-6" X 4'-0" (30" X 48")
• CLEAR SPACE BENEATH: 2'-5" HIGH, 2'-6" WIDE, 8 INCHES DEEP AT TOP, 1'-5" DEEP AT BOTTOM 9
INCHES. (CBC 11B-606.2 AND 11B-606.3)
• LAVATORIES ADJACENT TO A WALL SHALL BE MOUNTED WITH A MINIMUM DISTANCE OF 18" TO THE
CENTERLINE OF THE FIXTURE. (CBC 11B-606.6)
• CONTROL TO BE LEVER, PUSH-BUTTON, OR SIMILAR TYPE. CONTROL DOES NOT REQUIRE TIGHT
GRASPING, PINCHING OR TWISTING OF WRIST. ACTIVATION OF CONTROL SHALL NOT REQUIRE
GREATER THAN 5 FOOT LBS. OF FORCE. IF SELF CLOSING VALVES ARE USED, THEY MUST STAY
OPEN FOR MIN 10 SECONDS.
• HOT WATER AND DRAIN PIPES ACCESSIBLE UNDER LAVATORIES SHALL BE INSULATED OR
OTHERWISE COVERED. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER
LAVATORIES. (CBC 11B-606.5)
• SELF-CLOSING FAUCET CONTROL VALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT
LEAST TEN SECONDS.
• MIRRORS SHALL BE MOUNTED WITH THE BOTTOM EDGE NO HIGHER THAN 40" FROM THE FLOOR.
(CBC 11B-603.3)
TOILET COMPARTMENTS
• SIGNAGE: EQUILATERAL TRIANGLE (1'-0" SIDE) FOR MEN'S ROOM, 1'-0" DIAMETER CIRCLE FOR
WOMEN'S ROOM. (CBC 11B-703.7.2.6 AND 11B-703.7.2.6.2)
• UNISEX SANITARY FACILITIES SHALL BE IDENTIFIED BY A CIRCLE 1/4" THICK, 12" IN DIAMETER,WITH
A 1/4" THICK TRIANGLE SUPERIMPOSED ON THE CIRCLE AND WITHIN THE 12" DIAMETER. (CBC
11B-703.7.2.6.3)
• GEOMETRIC (CIRCLE AND TRIANGLE) SYMBOLS ON SANITARY DOORS SHALL BE CENTERED ON THE
DOOR AT A HEIGHT OF 58" MIN TO 60" MAX ABOVE FINISH FLOOR AND THEIR COLOR AND
CONTRAST SHALL BE DISTINCTLY DIFFERENT FROM THE COLOR AND CONTRAST OF THE DOOR.
(CBC 11B-703.7.2.6)
• SPACE IN FRONT OF DOOR: 4'-0"
• CLEAR DOOR WIDTH (FRONT ENTRY): 2'-8" CLEAR, DOOR SWINGS OUT.
• DOOR WIDTH (SIDE ENTRY): 2'-10" CLEAR, DOOR SWINGS OUT.
• COMPARTMENT WIDTH: 5'-0" MINIMUM DEPENDENT UPON WATER CLOSET.
• COMPARTMENT DEPTH (FRONT ENTRY): 6'-2" TO 6'-6" DEPENDENT UPON WATER CLOSET.
COMPARTMENT DEPTH (SIDE ENTRY): 7'-2" TO 7'-6" DEPENDENT UPON WATER CLOSET. CLEAR
SPACE AT SIDE OF WATER CLOSET: 2'-8" MINIMUM.
• NEAR WALL TO CENTER OF WATER CLOSET: 1'-5" TO 1'-6" CLEAR
• WATER CLOSET SEATS, FOR PUBLIC USE, SHALL BE ELONGATED TYPE AND EITHER OF THE OPEN
FRONT TYPE OR HAVE AN AUTOMATIC SEAT COVER DISPENSER (CPC 411.1 & 411.3)
• TOILET SEAT HEIGHT: 1'-5" TO 1'-7" HIGH.
• GRAB BAR DESIGN TO SUPPORT 250 LBS.
• REAR GRAB BAR: 3'-0" LONG MINIMUM.
• LONG SIDE GRAB BAR: 3'-6" LONG MINIMUM, 2'-0" EXTENSION MINIMUM IN FRONT OF WATER
CLOSET.
• GRAB BAR HEIGHT: 2'-9" TO 3'-0" ABOVE FLOOR TO CENTERLINE.
• TOILET PAPER HOLDER: 7"- 9" IN FRONT OF THE WATER CLOSET MEASURED TO THE CENTERLINE
OF THE DISPENSER. THE OUTLET OF THE DISPENSER SHALL BE BELOW THE GRAB BAR AND 19" MIN
ABOVE FINISH FLOOR. DISPENSERS THAT CONTROL DELIVERY OR THAT DO NOT PERMIT
CONTINUOUS PAPER FLOW SHALL NOT BE USED. (CBC 11B-604.7)
• TYPICAL WATER CLOSET SIZES:
• WIDTH: 1'-3" TO 1'-4" TYPICAL
• LENGTH: 2'-2" TO 2'-4" TYPICAL; 2'-0" TO 2'-7" AVAILABLE.
• CONTROL ON WIDE CLEAR SIDE OF WATER CLOSET, OPERABLE WITH ONE HAND. CONTROL DOES
NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF WRIST. ACTIVATION OF CONTROL
SHALL NOT REQUIRE GREATER THAN 5 FOOT LBS. OF FORCE (CBC 11B-309.4) AND SHALL BE
MOUNTED NO MORE THAN 44" ABOVE THE FLOOR. (CBC 11B-606.4) (CBC 11B-604.9.5) (CBC
11B-605.4)
SINGLE ACCOMMODATION TOILETS
• DOOR SHALL LOCK FROM INSIDE.
• ONE PERSON USE AT A TIME.
• SPACE INSIDE: ROOM FOR A WHEELCHAIR TO ENTER AND DOOR TO CLOSE.
• CLEAR SPACE IN FRONT OF WATER CLOSET: 4'-0" CLEARANCE
• AROUND A WATER CLOSET SHALL BE 60" MINIMUM MEASURED PERPENDICULAR FROM THE SIDE
WALL AND 56" MEASURED FROM THE REAR WALL.
• SIDE WALL TO CENTER OF WATER CLOSET: 1'-6"
• CLEAR CONTROL ON WIDE CLEAR SIDE OF WATER CLOSET:
• OPERABLE WITH ONE HAND. CONTROL DOES NOT REQUIRE TIGHT GRASPING, PINCHING OR
TWISTING OF WRIST. ACTIVATION OF CONTROL SHALL NOT REQUIRE GREATER THAN 5 FOOT
LBS. OF FORCE.
TOILET ROOM FLOOR
• FLOORS SHALL HAVE A SMOOTH, HARD, NON-ABSORBENT SURFACE SUCH AS PORTLAND CEMENT,
CONCRETE, CERAMIC TILE OR OTHER APPROVED MATERIAL WHICH EXTENDS UPWARD ONTO THE
WALLS AT LEAST 5". WALLS WITHIN WATER CLOSET COMPARTMENT AND WALLS WITHIN 24" OF
THE FRONT AND SIDES IF URINALS SHALL BE SIMILARLY FINISHED TO A HEIGHT OR 48" AND,
EXCEPT FOR STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS SHALL BE A TYPE
WHICH IS NOT ADVERSELY AFFECTED BY MOISTURE.
WHEELCHAIR CLEARANCE DIMENSIONS
• CLEAR FLOOR SPACE APPROACH TO FACILITIES: 2'-6" BY 4'-0"
• TURNING SPACE (180 AND 360 DEGREES): 5'-0" (60 INCHES) DIAMETER.
REACH FROM A WHEELCHAIR
• HIGH FORWARD: 48"
• HIGH SIDE: 48"
• LOW SIDE: 15" .
SANITARY FACILITIES FIXTURES & ACCESSORIES (PUBLIC USE PER CBC 11B)
FACILITIES ACCESS
WHEEL CHAIR
PUBLIC SANITARY FACILITIES
GRAB BARS (PUBLIC USE PER CBC 11B)
1. GRAB BARS SHALL BE LOCATED ON EACH SIDE, OR AN ONE SIDE AND THE BACK OF THE
ACCESSIBLE TOILET STALL OR COMPARTMENT. (CBC 11B-604.5)
2. GRAB BARS AT THE SIDE SHALL BE AT LEAST 42" LONG WITH THE FRONT END POSITIONED 24" IN
FRONT OF THE WATER CLOSET STOOL AND WITH THE BACK END POSITIONED NO MORE THAN 12"
FROM THE REAR WALL, GRAB BARS AT THE BACK SHALL BE NOT LESS THAN 36" LONG. (CBC
11B-604.5.1)
3. GRAB BARS SHALL BE SECURELY ATTACHED 33" MIN AND 36" MAX ABOVE AND PARALLEL TO THE
FLOOR MEASURED TO TOP OF GRIPPING SURFACE. (CBC 11B-609.4)
4. THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A GRAB BAR SHALL BE 1-1/4" TO 1-1/2"
OR THE SHAPE SHALL PROVIDE AN EQUIVALENT GRIPPING SURFACE. IF GRAB BARS ARE
MOUNTED ADJACENT TO A WALL, THE SPACE BETWEEN THE WALL AND THE GRAB BARS SHALL BE
1-1/2". (CBC 11B-609.2)
5. THE STRUCTURAL STRENGTH OF GRAB BARS, TUB AND SHOWER SEATS, FASTENERS, AND
MOUNTING DEVICES SHALL MEET THE FOLLOWING SPECIFICATIONS: (CBC 11B-609.8)
a. BENDING STRESS IN A GRAB BAR OR SEAT INDUCED BY THE MAXIMUM BENDING MOMENT
FROM THE APPLICATION OF A 250-LB. POINT LOAD SHALL BE LESS THAN THE ALLOWABLE
STRESS FOR THE MATERIAL OF THE GRAB BAR OR SEAT.
b. SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BY THE APPLICATION OF A 250-LB. POINT
LOAD SHALL BE LESS THAT THE ALLOWABLE SHEAR STRESS FOR THE MATERIAL OF HE GRAB
BAR OR SEAT, AND ITS MOUNTING BRACKET OR OTHER SUPPORT IS CONSIDERED TO BE
FULLY RESTRAINED, THEN DIRECT AND TORSIONAL SHEAR STRESSES SHALL NOT EXCEED THE
ALLOWABLE SHEAR STRESS.
c. SHEAR FORCE INDUCED IN FASTENER OR MOUNTING DEVICES FROM THE APPLICATION OF A
250-LB. POINT LOAD SHALL BE LESS THAN THE ALLOWABLE LATERAL LOAD OF EITHER THE
FASTENER OR MOUNTING DEVICE OR HE SUPPORTING STRUCTURE, WHICHEVER HAS THE
SMALLER ALLOWABLE LOAD.
d. TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT TENSION FORCE OF A 250-LB. POINT
LOAD, PLUS THE MAXIMUM MOMENT FORM THE APPLICATION OF A 250-LB. POINT LOAD, SHALL
BE LESS THAN THE ALLOWABLE WITHDRAWAL LOAD BETWEEN THE FASTENER AND
SUPPORTING STRUCTURE.
e. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS.
6. THE GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENT TO IT SHALL BE FREE OF ANY
SHARP OR ABRASIVE ELEMENTS AND SHALL BE ROUNDED EDGES (CBC 11B-609.5)
PUBLIC USE GRAB BAR
NOTE:
PROVIDE INSULATION OR OTHER
PROTECTION AT HOT WATER
SUPPLY AND DRAIN PIPES.
PROVIDE LEVER HANDLE FAUCET
NOT REQUIRING A GRASP TO
OPERATE. OPERATING FORCE
SHALL NOT EXCEED 5 POUNDS OR
SNSOR CONTROLLED FAUCET
REFER TO PLUMBING SCHEDULE
6"
MAX.
8"
MIN.
17" MIN.
TOE
CLEARANCE
KNEE
CLEARANCE
MI
N
9
1
/
2
"
27
"
M
I
N
.
29
"
M
I
N
.
34
"
M
A
X
.
CLEAR
FLOOR
SPACE30
"
M
I
N
.
17" MIN.
48" MIN.
18
"
M
I
N
.
19"
MAX.
SECTION
PLAN
CLEAR
FLOOR
SPACE
MIN.
48"
MI
N
.
30
"
FLUSH
VALVE
44
"
M
A
X
17
"
MA
X
LIP 14" MIN.
PROJECTION
FROM WALL
PLAN
SECTION
CBC FIGURE 11B-605.2CBC SECTION 11B-306.2
27
"
M
I
N
.
80
"
M
I
N
4"
MAX
MULTIPLE ACCOMMODATION TOILET FACILITY
AT STANDARD STALLS, MAINTAIN 15" CLEAR
FROM CENTERLINE OF WATER CLOSET TO
ADJACENT PARTITION / ACCESSORIES.
LOCATE FLUSH VALVE ON WIDE
SIDE TYP.-MOUNT +44" MAX.
(WHERE OCCURS)
1 1/4" - 1 1/2" DIA.GRAB BAR.
GRABBAR-FASTENERS AND
MOUNTINGS DESIGNED FOR
250 LB./L.F. LOAD
42"GRAB BAR, REFER TO
KEYNOTES FOR SPEC.
DOOR PERMITTED TO SWING
OVER HATCHED PORTION OF
MANEUVERING SPACE.
CBC 11B-604.8.1.1.2
60" MIN
17" - 18"32" MIN
SE
E
E
N
L
A
R
G
E
D
P
L
A
N
S
VA
R
I
E
S
SW
I
N
S
G
I
N
36
"
M
I
N
WH
E
N
D
O
O
R
S
W
I
N
G
I
N
59
"
M
I
N
AT
F
L
O
O
R
M
O
U
N
T
E
D
W
.
C
.
24
"
M
I
N
(C
B
C
1
1
B
-
6
0
4
.
8
.
1
.
)
60
"
M
I
N
CL
R
.
12
"
3
4
"
M
I
N
4
"
(C
B
C
1
1
B
-
6
0
4
.
8
.
1
.
)
60
M
I
N
A
T
O
U
T
S
W
I
N
G
D
O
O
R
CLR.
1 1/2"
CBC FIGURE 11B-604.8.1.1.2
MAX
>20-25
MA
X
44
"
MA
X
34
"
MA
X
34
"
MAX
<10" -24"
MA
X
46
"
CBC SECTION 11B-308.2.2
CBC SECTION 11B-308.3.2
MI
N
15
"
MA
X
48
"
MI
N
15
"
MA
X
48
"
MAX
10"
CBC SECTION 11B-308.2.1
CBC SECTION 11B-308.3.1
NOTE:
PROVIDE A 4" HIGH MIN. WATER STREAM.
AMEND PER CBC 11B-602.6
BASED ON DISTANCE FROM FRONT OF
FOUNTAIN
CL
R
.
18
"
M
I
N
.
CLR. ALCOVE
48" MIN.
CLEAR ALCOVE
48" MIN.
MIN
16"
MIN
16"
MIN
16"
ACCESSIBLE
FOUNTAIN, LO
15
"
M
I
N
.
CL CL
PLAN VIEW
ELEVATION
LOHI
CLR.
18" MIN.
TOE SPACE
17" MIN.
KN
E
E
S
P
A
C
E
27
"
M
I
N
.
15" MIN. 5" MAX.
SECTION
LO
HI
38
"
-
4
3
"
S
P
O
U
T
SP
A
C
E
38
"
-
4
3
"
S
P
O
U
T
SPACE
8" KNEE
SP
O
U
T
H
E
I
G
H
T
36
"
M
A
X
.
6" MAX.10 7/8" MIN.
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATEOF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
1
6
/
2
0
2
6
2
:
1
8
:
3
9
P
M
G-141
ACCESSIBILITY DETAILS &
NOTES
2510
Au
t
h
o
r
1/4" = 1'-0"OPERABLE PARTS-STANDARD MOUNTING HEIGHTS 5
3/4" = 1'-0"CLEARANCE AT LAVATORY 3
ACCESSIBILITY NOTES
1/2" = 1'-0"ACCESSIBLE TOILET 2
1/2" = 1'-0"OBSTRUCTED REACH 11
1/2" = 1'-0"UNOBSTRUCTED REACH 121/4" = 1'-0"LAVATORY AND URINAL 83/8" = 1'-0"MULTIPLE ACCOMODATION TOILET 10
1/2" = 1'-0"LIMITS OF PROTRUDING OBJECTS 9 1/2" = 1'-0"HI-LOW DRINKING FOUNTAIN CLEAR 13
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 04/06/2026
INT. VOLUME CONTROL
TELEPHONE SYMBOL
INTERNATIONAL TTY SYMBOL
INTERNATIONAL SYMBOL
OF ACCESS FOR
HEARING LOSS
CBC FIGURE 11B-703.7.2.2
CBC FIGURE 11B-70 3.7.2.3
CBC FIGURE 11B-703.7.2.4
DOOR STRIKE
SWING SIDE
OF DOOR
BUILDING WALL
DOOR / DOOR SWING
MINIMUM REQUIRED DOOR CLEARANCE
INTERIOR OR EXTERIOR DOOR - A LEVEL AND CLEAR FLOOR OR LANDING ON EACH SIDE OF
DOOR SHALL BE PROVIDED. THE LEVEL AREA SHALL HAVE A LENGTH IN THE DIRECTION OF
DOOR SWING OF AT LEAST 60" AND THE LENGTH OPPOSITE THE DIRECTION OF DOOR SWING
OF 48" AT DOORS WITH AUTOMATIC CLOSURES AS MEASURED AT RIGHT ANGLES TO THE
PLANE OF THE DOOR IN THE CLOSED POSITION CBC 11A-8A &11B-404.2.4.
1' - 0"
4'
-
0
"
@ INTERIOR DOORS
18" CLR.
@ EXTERIOR DOORS
24" CLR
4' - 0"
5'
-
0
"
5' - 0"
INDICATES MINIMUM CLEAR
SPACE AT DOOR
1. ACCESSIBLE ROUTE OF TRAVEL IS DEFINED AS "A CONTINUOUS UNOBSTRUCTED PATH
CONNECTING ALL ACCESSIBLE ELEMENTS AND SPACES IN AN ACCESSIBLE BUILDING OR FACILITY
THAT CAN BE NEGOTIATED BY A PERSON WITH A SEVERE DISABILITY USING A WHEELCHAIR AND
THAT IS ALSO SAFE FOR AND USABLE BY PERSONS WITH OTHER DISABILITIES.(CBC CHAPTER 2
SECTION 202).
2. THE ACCESSIBLE ROUTE SHALL BE PROVIDED WHERE REQUIRED (11B-206.2) SITE ARRIVAL POINTS
AND WITHIN A SITE.
3. EACH REQUIRED ACCESSIBLE MEANS OF EGRESS SHALL BE CONTINUOUS TO A PUBLIC WAY AND
SHALL CONSIST OF ONE OR MORE OF THE FOLLOWING COMPONENTS LISTED IN CBC 2022 CHAPTER
10 SECTION 1009.2.
4. ANY PATH OF TRAVEL SHALL BE CONSIDERED A RAMP IF ITS SLOPE IS GREATER THAN 1' RISE IN 20'
OF HORIZONTAL RUN (5-PERCENT SLOPE). (CBC CHAPTER 2 SECTION 202)
5. THE ARCHITECT SHALL VERIFY THAT THERE ARE NO BARRIERS IN THE PATH OF TRAVEL.
• GENERAL CONTRACTOR TO VERIFY EXISTING SIGNAGE IN FIELD AND PROVIDE NEW AS REQUIRED
TO COMPLY WITH APPLICABLE BUILDING CODES.
• ALL SIGNAGE SHALL CONFORM WITH ADA ACCESSIBILITY GUIDELINES,INCLUDING BUT NOT LIMITED
TO PROPORTION, COLOR CONTRAST AND RELIEF AND GRADE 2 BRAILLE REQUIREMENTS.
• SIGNAGE: AFFIX AN INTERNATIONAL ACCESSIBILITY SYMBOL ON ALL ACCESSIBLE ENTRANCES PER
APPLICABLE BUILDING CODE.
• STRIKE EDGE CLEARANCE AT DOORWAY WITH FORWARD APPROACH: PROVIDE AN 18" STRIKE EDGE
CLEARANCE ON THE PULL SIDE OF INTERIOR DOORS. (FIG 11B-404.2.3 a), SEE 14/--. PROVIDE A 24"
STRIKE EDGE CLEARANCE ON THE PULL SIDE OF THE EXTERIOR DOORS. (FIG 11B-404.2.3 b), SEE
14/--. PROVIDE A 12" STRIKE EDGE CLEARANCE ON THE PUSH SIDE OF ALL DOORS WHICH HAVE
BOTH A LATCH AND A CLOSER. (FIG 11B-404.2.4.3), SEE 14/--.
• TACTILE EXIT SIGNAGE:
A TACTILE EXIT SIGN WITH THE WORD "EXIT" SHALL IDENTIFY
• EACH GRADE LEVEL EXTERIOR EXIT DOOR. A TACTILE EXIT SIGN WITH THE WORDS "EXIT ROUTE"
SHALL IDENTIFY EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM OR AREA TO A CORRIDOR OR
HALLWAY THAT IS REQUIRED TO HAVE A VISUAL EXIT SIGN.
• GENERAL CONTRACTOR TO VERIFY EXISTING SIGNAGE INSTALLATIONS AND PROVIDE NEW AS
REQUIRED.
• CHARACTERS, SYMBOLS AND BACKGROUND SHALL HAVE A NON-GLARE FINISH.
• CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THE BACKGROUND, EITHER LIGHT ON DARK
BACKGROUND OR DARK ON LIGHT BACKGROUND.
• SIGNS TO INCLUDE BRAILLE AND CHARACTERS AS DEFINED BY CODE. MOUNT SIGNAGE SO THAT
TACTILE CHARACTERS ON SIGN ARE LOCATED 48" MIN AFF MEASURED FROM THE BASELINE OF THE
LOWEST BRAILLE CELLS AND 60" MAX AFF MEASURED TO THE BASELINE OF THE HIGHEST LINE OF
RAISED CHARACTERS. MOUNTING LOCATION SHALL BE ON THE LATCH SIDE OF THE DOOR
MOUNTED SO THAT A CLEAR FLOOR SPACE OF 18" MIN X 18" MIN, CENTERED ON THE TACTILE
CHARACTERS, IS PROVIDED BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE CLOSED
POSITION AND 45 DEGREE OPEN POSITION. (CBC 11B-703.4.1 & 11B-703.4.2)
• SIGN SHALL COMPLY WITH CBC 11B-21
1. EXIT AS DEFINED IS "A CONTINUOUS AND UNOBSTRUCTED MEANS OF EGRESS TO A PUBLIC WAY
AND SHALL INCLUDE INTERVENING AISLES, DOORS, DOORWAYS, GATES, CORRIDORS, EXTERIOR
EXIT BALCONIES, RAMPS, STAIRWAYS, SMOKE PROOF ENCLOSURES, HORIZONTAL EXITS, EXIT
PASSAGEWAY, EXIT COURTS, AND YARDS".
2. FOR THE PURPOSES OF TITLE 24, THE USE OF THE TERM "EXIT DOOR" IN SECTION 1007 APPLIES TO
ALL DOORS THAT PROVIDE ACCESS, THAT IS, ENTRANCES, PASSAGE DOORS, ETC.
3. ALL ENTRANCES AND ALL EXTERIOR GROUND FLOOR EXIT DOORS TO BUILDING AND FACILITIES
SHALL BE MADE ACCESSIBLE TO PERSONS WITH DISABILITIES.
4. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL
KNOWLEDGE OR EFFORT
5. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL
SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC BARS, PUSH-PULL
ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING
IN EGRESS DIRECTION.
6. HAND-ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 34" AND 44" ABOVE
THE FLOOR. (CBC 11B-404.2.7)
7. EVERY DOORWAY WHICH IS LOCATED WITHIN AN ACCESSIBLE PATH OF TRAVEL SHALL BE OF A SIZE
AS TO PERMIT THE INSTALLATION OF A DOOR NOT LESS THAN 3' IN WIDTH AND NOT LESS THAN 6'-8"
IN HEIGHT. WHEN INSTALLED, EXIT DOORS SHALL BE CAPABLE OF OPENING SO THAT THE CLEAR
WIDTH OF THE EXIT IS NOT LESS THAN 32".
8. FOR HINGED DOORS, THE OPENING WIDTH SHALL BE MEASURED WITH THE DOOR POSITIONED AT
AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION.
9. WHERE A PAIR OF DOORS IS UTILIZED, AT LEAST ONE OF THE DOORS SHALL PROVIDE A CLEAR,
UNOBSTRUCTED OPENING WIDTH OF 32" WITH THE LEAF POSITIONED AT AN ANGLE OF 90 DEGREES
FROM ITS CLOSED POSITION.
10. MINIMUM MANEUVERING CLEARANCES AT DOORS SHALL BE AS SHOWN IN FIGURES. THE FLOOR OR
GROUND AREA WITHIN THE REQUIRED CLEARANCES SHALL BE LEVEL AND CLEAR.
11. THERE SHALL BE A LEVEL AND CLEAR FLOOR OR LANDING ON EACH SIDE OF A DOOR. THE LEVEL
AREA SHALL HAVE A LENGTH IN THE DIRECTION OF DOOR SWING OF AT LEAST 60" AND THE LENGTH
OPPOSITE THE DIRECTION OF DOOR SWING OF 48" AS MEASURED AT RIGHT ANGLES TO THE PLANE
OF THE DOOR IN THE HE CLOSED POSITION.
12. THE WIDTH OF THE LEVEL AREA ON THE SIDE TO WHICH THE DOOR SWINGS SHALL EXTEND A
MINIMUM OF 24" PAST THE STRIKE EDGE OF THE DOOR FOR EXTERIOR DOORS AND A MINIMUM OF
18" PAST THE STRIKE EDGE FOR INTERIOR DOORS.
13. THE FLOOR OR LANDING SHALL BE NOT MORE THAN 1/2" LOWER THAN THE THRESHOLD OF THE
DOORWAY. (CBC 11B-404.2.5)
14. THE BOTTOM 10" OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH,
UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST
WITHOUT CREATING A RAP OR HAZARDOUS CONDITION. WHERE NARROW FRAME DOORS ARE
USED, A 10" HIGH SMOOTH PANEL SHALL BE INSTALLED ON THE PUSH SIDE OF THE DOOR, WHICH
WILL ALLOW THE DOOR TO BE OPENED BY A WHEEL CHAIR FOOTREST WITHOUT CREATING A TRAP
OR HAZARDOUS CONDITION.
15. MAXIMUM, EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR DOORS AND
INTERIOR DOORS, SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED
DOORS AND OF THE CENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSATING DEVICES OR
AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. WHEN FIRE
DOORS ARE REQUIRED, THE MAXIMUM EFFORT TO OPERATE THE DOOR MAY BE INCREASED TO THE
MAXIMUM ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15
POUNDS. (CBC 11B-404.2.9)
ENTRANCES
• ALL PRIMARY ENTRANCES TO BE ACCESSIBLE.
• LEVEL SPACE AT OUT-SWINGING DOORS: 5'-0"
• SPACE PROVIDED AT STRIKE SIDE OF OUT-SWINGING EXTERIOR DOORS: 2'-0"
• LEVEL SPACE AT IN-SWINGING DOORS: 5'-0"
• WIDTH: 2'-8" CLEAR OPENING (3'-0" DOOR)
• DOUBLE DOORS WIDTH: ACTIVE LEAF 2'-8" CLEAR OPENING.
• UNINTERRUPTED BOTTOM RAIL SPACE AT DOOR BOTTOM: 10"
• NO REVOLVING DOORS ALLOWED FOR ACCESSIBLE DOORS.
DOORS
• LEVEL SPACE ON SWING SIDE: 5'-0"
• LEVEL SPACE ON SIDE AWAY FROM SWING: 3'-8" WITHOUT CLOSER AND 4'-0" WITH CLOSER
• SPACE PROVIDED ON STRIKE SIDE OF INTERIOR DOOR, PULL SIDE: 18"
• SPACE PROVIDED ON PUSH SIDE JAMB WITH BOTH A LATCH AND CLOSER: 12" AND NO
REQUIREMENT FOR JAMB SIDE WITHOUT LATCH AND CLOSER.
• WIDTH: 2'-8" CLEAR OPENING (3'-0" DOOR)
• HEIGHT: 6'-8" MIN.
DOOR HARDWARE
• DOOR HARDWARE SHALL COMPLY WITH THE CALIFORNIA REFERENCED STANDARDS CODE (CRSC),
SECTION 12-10-202, AS ADOPTED BY THE STATE FIRE MARSHALL FOR ALL OCCUPANCIES.
• LEVER HANDLES SHALL COMPLY WITH SUBSECTION (f): LEVERS MUST BE CURVED AND SHALL
RETURN TO WITHIN ½ INCH OF THE DOOR, SHALL BE CENTERED BETWEEN 34 INCHES MIN. AND 44
INCHES MAX. ABOVE THE FLOOR. CBC 2022 11B-404.2.7 OPERABLE BY A SINGLE EFFORT, NO
GRASPING OR WRIST MOVEMENT (LEVERS, PUSH-PULLS, OR PANIC DEVICES).
• MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 LBS - FIRE DOORS: 15 POUNDS
CLOSER
• DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES, THE TIME
REQUIRED TO MOVE THE DOOR TO APPOSITION OF 12 DEGREES FROM THE LATCH IS 5 SECONDS
MINIMUM. CBC11B-404.2.8
THRESHOLDS
• THRESHOLDS AT DOORWAYS SHALL BE 1/2" HIGH MAXIMUM. THE FLOOR OR LANDING SHALL NOT BE
MORE THAN ½ INCH LOWER THAN THE THRESHOLD OF THE DOORWAY.
• CHANGE IN LEVEL BETWEEN ¼ INCH AND ½ INCH SHALL BE BEVELED WITH A SLOPE NO GREATER
THAN ONE UNIT VERTICAL IN 2 UNITS HORIZONTAL (50-PERCENT SLOPE).
• CHANGE IN LEVEL GREATER THAN ½ INCH SHALL BE ACCOMPLISHED BY MEANS OF A RAMP.
FLOORS
• FLOOR FINISHES ALONG ACCESSIBLE ROUTES AND IN ACCESSIBLE ROOMS AND SPACES,
INCLUDING FLOORS, WALKS, RAMPS, STAIRS AND CURB RAMPS, SHALL BE STABLE, FIRM, AND SLIP
RESISTANT.
CORRIDORS
• EVERY CORRIDOR AND HALLWAY SERVING AN OCCUPANT LOAD OF (10) OR MORE SHALL NOT BE
LESS THAN 44 INCHES IN WIDTH. CORRIDORS AND HALLWAYS SERVING AN OCCUPANT LOAD OF
LESS THAN (10) SHALL NOT BE LESS THAN 36 INCHES IN WIDTH
CONTROLS FOR LIGHTS, WINDOWS, TEMPERATURE CONTROLS, ETC.
• HEIGHT: MAXIMUM 4'-0" AT WALL
• OUTLETS: 15" A.F.F. TO BOTTOM OF OUTLET
• ACTIVATION FORCE: 5 POUNDS
HAZARDS
• OVERHEAD OBSTRUCTIONS: 6'-8"
• PROJECTIONS: MAXIMUM 4 INCHES IF OVER 2'- 3" ABOVE FLOOR. PROVIDE TEXTURED PATH WHEN
OBSTRUCTIONS ARE IN THE PATH OF TRAVEL.
• EMERGENCY SIGNALS: AUDIBLE AND VISUAL. WHERE LIGHTED EXIT SIGNS ARE USED, THEY SHALL
FLASH IN AN EMERGENCY.
SIGNAGE
• EACH GRADE-LEVEL EXTERIOR EXIT DOOR SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE
WORD "EXIT". SIGNS WITH RAISED CHARACTERS AND BRAILLE SHALL BE LOCATED 48 INCHES
MINIMUM ABOVE FINISHED FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE
LOWEST LINE OF BRAILLE AND 60 INCHES MAXIMUM ABOVE THE FINISHED FLOOR OR GROUND
SURFACE, MEASURED FROM THE BASELINE OF THE HIGHEST LINE OF RAISED CHARACTERS. THE
BRAILLE CHARACTERS SHOULD BE ALIGNED TO THE LEFT SIDE OR CENTER ALIGNED. CBC
11B-703-3.2 & 11B-703.4.1.
• PLACE A SIGN AT EVERY PUBLIC ENTRANCE AND AT EVERY MAJOR JUNCTION ALONG OR LEADING
TO AN ACCESSIBLE PATH OF TRAVEL DISPLAYING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY.
SIGNS SHALL INDICATE THE DIRECTION TO ACCESSIBLE FACILITY ENTRANCES AND COMPLY WITH
CBC SECTION 11B-703.7.
PATH OF TRAVEL AND ACCESSIBLE ROUTE
SIGNAGE , DOORS AND DOORWAYS
ENTRANCE AND EXITS
BUILDING ACCESS
STAINLESS STEEL
KICK PLATE
DOOR MOUNTED RESTROOM
SIGNAGE IN EQUILATERAL
TRIANGLE, 1/4" THICK
W/EDGES, 12" LONG, 60" HIGH
A.F.F. POINTING UPWARDS
(SEE DETAIL)
PERMANENT ROOM
IDENTIFICATION SIGNAGE W/
BRAILLE ON STRIKE SIDE OF
DOOR(SEE DETAIL)
MEN'S RESTROOM DOOR
CL
CL
NOTES:
1. LEVER-STYLE HARDWARE
ON BOTH SIDES OF DOORS.
2. ALUMINUM DOOR-MOUNTED
RESTROOM SIGNAGE (MATTE
FINISH ON BLACK
BACKGROUND)
3. SIGNAGE IS LOCATED
CENTERED IN DOOR LEAF AT
60" ABOVE FINISHED FLOOR.
MEN
MEN
CL
WOMEN
WOMEN
CL
CL
ALL GENDER
RESTROOM
WOMEN'S RESTROOM DOORALL GENDER RESTROOM DOOR
ALL-GENDER
RESTROOM
DOOR MOUNTED RESTROOM
SIGNAGE IN EQUILATERAL
TRIANGLE, 1/4" THICK
W/EDGES, 12" LONG, 60"
HIGH A.F.F. POINTING
UPWARDS (SEE DETAIL)
SINGLE-USER STATEMENT
AS - "UNISEX RESTROOM",
"ALL GENDER RESTROOM",
"RESTROOM"(TACTILE/BRAILE
COMPLIANT
NOTES:
1. LEVER-STYLE HARDWARE
ON BOTH SIDES OF DOORS.
2. ALUMINUM DOOR-MOUNTED
RESTROOM SIGNAGE (MATTE
FINISH ON BLACK
BACKGROUND)
3. SIGNAGE IS LOCATED
CENTERED IN DOOR LEAF AT
60" ABOVE FINISHED FLOOR.
CL CL
STAINLESS STEEL
KICK PLATE
STAINLESS STEEL
KICK PLATE
CL CL
3
TOILET ROOM IDENTIFYING SIGNAGE
NOTE:
• PICTORIAL SYMBOL SIGNS SHALL BE ACCOMPANIED BY THE EQUIVALENT WRITTEN
DESCRIPTION PLACED DIRECTLY BELOW THE PICTOGRAM. THE BORDER DIMENSION OF ANY
PICTOGRAM SHALL BE A MINIMUM OF 6" IN HEIGHT. TOILET ROOM SIGNS SHALL BE 1/4" THICK
MATERIAL AND SHALL BE A CONTRASTING COLOR TO THE DOOR AND BACKGROUND.
• ACCESSIBILITY SIGN MOUNTING HEIGHT PER CBC 11B-703.4.1
TYP. RESTROOM SIGNAGE
12"
MEN
WOMEN
6"
M
I
N
WOMEN
MEN
2"
M
A
X
5/
8
"
M
I
N
1/
2
"
M
A
X
3/
8
"
M
I
N
3/
8
"
M
I
N
2"
M
A
X
5/
8
"
M
I
N
1/
2
"
M
A
X
3/
8
"
M
I
N
3/
8
"
M
I
N
6"
M
I
N
FIELD W/ SYMBOLS
FIELD W/ TEXT CORRESPONDING TO GRADE 2
BRAILLE; MIN. 5/8" HIGH RAISED TYPE; MINIMUM 1/32"
THICK; HELVETICA MEDIUM UPPERCASE FONT
CL
48
"
M
I
N
60
"
M
A
X
CL
48
"
M
I
N
60
"
M
A
X
CL
58
"
M
I
N
60
"
M
A
X
12"
CL
58
"
M
I
N
60
"
M
A
X
PICTOGRAM &
INTERNATIONAL
SYMBOL: COLOR
BLUE, TYP
TACTILE WOMEN'S
ROOM SIGN
ROOM NAME:
COLOR: WHITE, TYP.
TACTILE MEN'S
ROOM SIGN
ROOM SIGN ATTACHED TO
WALL
SIGNAGE BACKING TO MATCH
SIGN (AND MESSAGE CLIP,
WHERE APPLICABLE)
WALL PER PLAN
JAMB BEYOND
FIN. FLR.
NOTE:
PROVIDE A BLANK MATCHING
PANEL ON REVERSE SIDE
WHERE THERE ARE NO BACK TO
BACK SIGNAGE
60
"
A
.
F
.
F
.
M
A
X
.
TO
B
O
T
T
O
M
O
F
T
O
P
M
O
S
T
T
A
C
T
I
L
E
LE
T
T
E
R
S
48
"
A
.
F
.
F
.
M
I
N
.
TO
B
O
T
T
O
M
O
F
B
R
A
I
L
L
E
PROPORTIONS DISPLAY CONDITIONS
CBC FIGURE 11B-703.7.2.1
24
"
MA
X
48
M
I
N
24
"
MA
X
CBC FIGURE 11B-305.5
ABAAS FIGURE 305.5
POSITION OF CLEAR FLOOR
OR GROUND SPACE
32" MIN
36" MIN
48
"
MI
N
36" MIN
X
>
2
4
"
CBC FIGURE 11B-305.7.1
ABAAS FIGURE 305.7.1
MANUEVERING CLEARANCE
IN AN ALCOVE, FORWARD
APPROACH
60" MIN
X
>
1
5
CBC FIGURE 11B-305.7.2
ABAAS FIGURE 305.7.2
MANUEVERING CLEARANCE IN AN
ALCOVE, PARALLEL APPROACH
30
"
M
I
N
48" MIN
30" MIN
60" DIAMETER SPACE
60"
CBC FIGURE 11B-403.5.1
ABAAS FIGURE 403.5.1
CLEAR WIDTH FOR AN ACCESSIBLE ROUTE
CBC FIGURE 11B-304.3.1
T-SHAPED SPACE FOR 180 DEGREE
TURNS
CBC FIGURE 11B-802.1.2
ABAAS FIGURE 802.1.2
WIDTH OF WHEELCHAIR SPACES
36"33" 33"
CBC FIGURE 11B-304.3.2
ABAAS FIGURE 304.3.2
T-SHAPED TURNING SPACE
A
B
60
"
36
"
2
4
"
60"
12" 36" 12"
48
"
(F) HINGE APPROACH,
PUSH SIDE
44
"
M
I
N
36"60
"
M
I
N
(D) HINGE APPROACH,
PULL SIDE
(A) FRONT APPROACH,
PULL SIDE
OF EXT. DOORS
24" MIN
AT EXT. SIDE
60
"
M
I
N
MIN
18"
22
MIN
(C) FRONT APPROACH, PUSH
SIDE, DOOR PROVIDED WITH
BOTH CLOSER AND LATCH
48
"
M
I
N
.
12"
(B) FRONT APPROACH,
PUSH SIDE
48
"
M
I
N
(G) HINGE APPROACH, PUSH
SIDE, DOOR PROVIDED WITH
BOTH CLOSER AND LATCH
48
"
M
I
N
22
MIN
(H) LATCH APPROACH, PULL
SIDE
MIN
24"
48
"
M
I
N
MIN
24"
(K) LATCH APPROACH, PUSH
SIDE, DOOR PROVIDED WITH
BOTH CLOSER
60
"
M
I
N
44
"
M
I
N
MIN
24"
(J) LATCH APPROACH, PUSH
SIDE,
(K) LATCH APPROACH,
PULL SIDE, DOOR
PROVIDED WITH CLOSER
MIN
24"48
"
M
I
N
CBC FIGURE 11B-404.2.4.1
ABAAS FIGURE 404.2.4.1
STAIR
DOWN
EXIT
7
.
9
"
14.6" .8"
6"
6"
ROUTE
EXIT
EXIT
6"
6"
8 1/4"
1'
-
0
"
1. SIGN MATERIAL TO BE 1/8" THICK PLASTIC W/ 1/32" RAISED BORDER, GRAPHIC AND
LETTERS.
2. LOCATE SIGN MAX. 12" AWAY FROM DOOR STRIKE SIDE.
3. LETTER AND NUMBERS ON SIGN SHALL HAVE A WIDTH-TO HEIGHT RATIO BETWEEN 3:5 AND
1:1 AND STROKE WIDTH-TO-HEIGHT BETWEEN 1:5 AND 1:10.
4. SIGN TO BE MOUNTED SO THAT TACTILE CHARACTERS ON SIGN ARE LOCATED 48" MIN AFF
MEASURED FROM THE BASELINE OF THE LOWEST BRAILLE CELLS AND 60" MAX AFF
MEASURED TO THE BASELINE OF THE HIGHEST LINE OF RAISED CHARACTERS PER SEC
11B-703.4.1
TACTILE EXIT SIGN
EXIT ROUTE SIGNEXIT STAIR DOWN SIGN
ACCESSIBLE
ACCESSIBILITY SYMBOL
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATEOF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
1
6
/
2
0
2
6
2
:
1
8
:
3
9
P
M
G-142
ACCESSIBILITY DETAILS &
NOTES
2510
Au
t
h
o
r
3" = 1'-0"SIGN ATTACHMENT 8
PATH OF TRAVEL, SIGNAGE AND ACCESS
3" = 1'-0"RESTROOM SIGNS 7
1" = 1'-0"RESTROOM SIGNS 6
1/4" = 1'-0"ACCESSIBLE CLEAR FLOOR OR MANUEVERING CLEARANCES 10
1/4" = 1'-0"MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES 11
12" = 1'-0"INTERNATIONAL ACCESSIBILITY SYMBOL 9N.T.S.ACCESS INT'L SYM FOR HEARING LOSS 1
3" = 1'-0"TACTILE ACCESSIBILITY SIGNAGE 12
1/4" = 1'-0"DOOR CLEARANCE 3
1. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE THE STANDARD USED TO IDENTIFY FACILITIES
THAT ARE ACCESSIBLE TO AND USABLE BY PHYSICALLY DISABLED PERSONS AS SET FORTH IN TITLE 24
AND AS SPECIFICALLY REQUIRED IN THIS SECTION.
2. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL CONSIST OF A WHITE FIGURE ON A BLUE
BACKGROUND. THE BLUE SHALL BE EQUAL TO COLOR NO. 15090 IN FEDERAL STANDARD 595B.
3. LETTERS AND NUMBERS ON SIGNS SHALL HAVE A WIDTH-TO-HEIGHT RATIO OF BETWEEN 3:5 AND 1:1 AND
A STROKE WIDTH-TO-HEIGHT RATIO BETWEEN 1:5 AND 1:10.
4. CHARACTERS AND NUMBERS ON SIGNS SHALL BE SIZED ACCORDING TO THE VIEWING DISTANCE FROM
WHICH THEY ARE TO BE READ. THE MINIMUM HEIGHT IS MEASURED USING AN UPPER CASE "I". LOWER
CASE CHARACTERS ARE PERMITTED . FOR SIGNS SUSPENDED OR PROJECTED ABOVE THE FINISH FLOOR
IN THE MINIMUM CHARACTER HEIGHT SHALL BE 3".
5. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND, EITHER LIGHT CHARACTERS
ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUNDS.
6. WHEN RAISED CHARACTERS OR SYMBOLS ARE USED, THEY SHALL CONFORM TO THE FOLLOWING:
a. LETTER AND NUMBERS ON SIGN SHALL BE RAISED 1/32" MINIMUM (CBC 11B-703.2.1) AND SHALL BE SAN-
SERIF UPPERCASE CHARACTERS ACCOMPANIED BY GRADE 2 BRAILLE COMPLYING WITH (CBC 11B-702.2.3)
b. RAISED CHARACTER OR SYMBOLS SHALL BE MINIMUM OF 5/8" HIGH & MAX OF 2".
c. PICTORIAL SYMBOL SIGNS (PICTOGRAMS) SHALL BE ACCOMPANIED BY THE EQUIVALENT DESCRIPTION
VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE PICTOGRAM. THE BORDER DIMENSION OF THE
PICTOGRAM SHALL BE A MINIMUM OF 6" IN HEIGHT. (CBC 11B-703.60).
7. CONTRACTED (GRADE 2) BRAILLE SHALL BE USED WHEREVER BRAILLE IS REQUIRED IN OTHER PORTIONS
OF THESE STANDARDS. DOTS SHALL BE 2.50 MM) ON CENTER IN EACH CELL WITH (7.6 MM) SPACE
BETWEEN CELLS, MEASURED FROM THE FIRST COLUMN OF DOTS IN THE FIRST CELL TO THE FIRST
COLUMN OF DOTS IN THE SECOND CELL. DOTS SHALL BE RAISED A MINIMUM OF (0.60 MM) ABOVE THE
BACKGROUND. BRAILLE DOTS SHALL BE DOMED OR ROUNDED.
8. ENTRANCES TO BUILDINGS AND FACILITIES THAT ARE ACCESSIBLE TO AND USABLE BY PERSONS WITH
DISABILITIES SHALL BE IDENTIFIED WITH A MINIMUM OF ONE INTERNATIONAL SYMBOL OF ACCESSIBILITY
AND WITH ADDITIONAL DIRECTIONAL SIGNS, UTILIZING THE SYMBOL, AT JUNCTIONS WHERE THE
ACCESSIBLE ROUTE OF TRAVEL DIVERGES FROM THE REGULAR CIRCULATION PATH, TO BE VISIBLE TO
PERSONS ALONG APPROACHING CIRCULATION PATHS. IN EXISTING BUILDINGS AND FACILITIES,
ENTRANCES WHICH ARE NOT ACCESSIBLE SHALL HAVE DIRECTIONAL SIGNAGE COMPLYING WITH
INDICATES THE LOCATION OF AND ROUTE TO THE NEAREST ACCESSIBLE ENTRANCE.
9. WHEN PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES, RAISED LETTERS SHALL BE
PROVIDED AND SHALL BE ACCOMPANIED BY BRAILLE IN CONFORMANCE WITH (CBC 11B-703.3) SIGNS
SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH OUTSIDE OF THE DOOR. WHERE THERE IS
NO WALL SPACE ON THE LATCH SIDE, INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON
THE NEAREST ADJACENT WALL, PREFERABLY ON THE RIGHT. MOUNT SIGNAGE SO THAT TACTILE
CHARACTERS ON SIGN ARE LOCATED 48" MIN AFF MEASURED FROM THE BASELINE OF THE LOWEST
BRAILLE CELLS AND 60" MAX AFF MEASURED TO THE BASELINE OF THE HIGHEST LINE OF RAISED
CHARACTERS. MOUNTING LOCATION SHALL BE ON THE LATCH SIDE OF THE DOOR MOUNTED SO THAT A
CLEAR FLOOR SPACE OF 18" MIN X 18" MIN, CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED
BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE CLOSED POSITION & 45 DEGREE OPEN POSITION.
SIGNAGE ACCESSIBILTY REQUIREMENTS
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 04/06/2026
3 PLAN RESUBMITTAL 2 04/16/2026
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATEOF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
1
6
/
2
0
2
6
2
:
1
8
:
4
3
P
M
A-001
AS-BUILT REFERENCE
2510
Au
t
h
o
r
NOT FOR
CONSTRUCTION
AS-BUILT DETAILS
SHOWN FOR
REFERENCE ONLY
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 04/06/2026
WEST MACARTHUR BLVD
MA
I
N
S
T
R
E
E
T
PROJECT
LOCATION
(E) GAS
STATION
EV
SP
A
C
E
(E) TRASH
ENCLOSURE
(E) ROOF
COVER OF
GAS STATION
G-140
5
TYP.
G-140
5
TYP.
G-140
2
TYP.
G-140
14
TYP.
(E) ACCESSIBLE
PARKING
(E) ACCESSIBLE
PARKING
G-140
8
TYP.
(E) DETECTABLE
WARNING, TYP.(E) DETECTABLE
WARNING, TYP.
(E) ACC.
SIGNAGE, TYP.
SEE SHEET G-140
(E) TRANSFORMER(E) TRASH
ENCLOSURE
A-210
3
NO PARKING
(E) GGI TANK
(E) UNIT GAS AND
WATER METER, SEE
PLUMBING PLANS
CITY WATER MAIN
EXISTING 2"
WATER METER
EXISTING 2" WATER
SERVICE FROM
WATER MAIN UP TO
WATER METER
2
1
ARCHITECTURAL
LAYOUT - LAYOUT AND VERIFY ALL DIMENSIONS PRIOR TO START OF WORK. BRING DISCREPANCIES TO
THE ARCHITECT’S ATTENTION.
CONCRETE PAVING SAWCUT
SAWCUT EXISTING REINFORCED CONCRETE WALKWAYS AS REQUIRED FOR NEW WORK. DOWEL AND
EPOXY REBAR AT FACE OF SAWCUT WHERE EXISTING WORK IS TO REMAIN. SEE STRUCTURAL
DRAWINGS. ALL CONCRETE SHALL BE PORTLAND CEMENT CONCRETE WITH ULTIMATE 28 DAY MINIMUM
COMPRESSIVE STRENGTH OF 3,000 PSI UNLESS NOTED OTHERWISE IN OWNER’S GEO-TECHNICAL
REPORT.
NOISE LEVEL COMPLIANCE
COMPLY WITH LOCAL NOISE LEVELS DURING NORMAL BUSINESS HOURS AND OBTAIN PERMISSION FOR
AFTER-HOURS CONSTRUCTION ACTIVITY WHEN APPLICABLE. DIRECT NOISE COMPLAINTS TO THE
CONSTRUCTION MANAGER.
CLEAN JOBSITE
AT THE CONCLUSION OF EACH WORK DAY, LEAVE SITE CLEAN, NEAT AND ORDERLY WITH MATERIALS
AND EQUIPMENT LOCATED TO AVOID SAFETY CONCERNS. CONTRACTOR HAS SOLE RESPONSIBILITY
FOR JOBSITE SAFETY.
GEO-TECHNICAL REPORT
SEE OWNER’S GEOTECHNICAL REPORT FOR SUBGRADE AND COMPACTION CRITERIA UNDER
PAVEMENT.
EXPANSION / CONTROL JOINTS
CONCRETE WALKS SHALL RECEIVE EXPANSION JOINTS AT 15'-0" O.C. MAX AND CONTROL JOINTS AT 5'-0"
O.C. MAX UNLESS OTHERWISE NOTED
PARKING STALL STRIPING
ALL PARKING STALL STRIPING SHALL BE PER LOCAL JURISDICTION STANDARDS.
DIMENSIONS
ALL DIMENSIONS ON SITE PLAN ARE TO BE FACE OF WALL FINISH, FACE OF CONCRETE CURB,
PROPERTY LINE OR CENTERLINE OF PARKING STALL, UNLESS NOTED OTHERWISE.
EXISTING WORK
ALL EXISTING WORK IS TO REMAIN UNLESS NOTED OTHERWISE. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR REPAIRING OR REPLACING AT THE CONTRACTOR’S EXPENSE ANY EXISTING ITEM
DAMAGED BY CONSTRUCTION AND, OR DEMOLITION ACTIVITY. THE DAMAGED ITEMS SHALL BE
RESTORED TO AN “AS-WAS” OR BETTER CONDITION, OR REPLACES AT THE OWNER’S DISCRETION.
WASTE MANAGEMENT
CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTION WASTE MANAGEMENT COMPLIANCE DEFINED BY
LOCAL GREEN BUILDING ORDNANCE(S), INCLUDING BUT NOT LIMITED TO SORTING AND SEPARATING
MATERIALS DERIVED FROM CONSTRUCTION AND DEMOLITION DEBRIS INCLUDING BUT NOT LIMITED TO
CONCRETE, REINFORCING STEEL AND ASPHALT.
TRAFFIC & PEDESTRIAN ACCESS
SCHEDULE CONSTRUCTION WASTE MATERIAL REMOVAL IN A MANNER TO INSURE MINIMUM
INTERFERENCE WITH VEHICLE TRAFFIC AND PEDESTRIAN ACCESS INCLUDING ADJACENT PROPERTIES
WHEN APPLICABLE, PER LOCAL REQUIREMENTS.
SITE DRAINAGE
CONTRACTOR SHALL MAINTAIN NECESSARY TEMPORARY SITE DRAINAGE DURING DEMOLITION AND
CONSTRUCTION ACTIVITY.
LANDSCAPE PROTECTION
PROTECT EXISTING PLANTING AREAS INCLUDING TREES, SHRUBS, TURF AND IRRIGATION SYSTEM
SHOWN TO REMAIN. COORDINATE NEW WORK WITH EXISTING AS-BUILT FIELD CONDITIONS. SEE
LANDSCAPE DRAWINGS.
CONSTRUCTION BARRICADES
CONTRACTOR BEARS SOLE RESPONSIBILITY FOR CONSTRUCTION BARRICADES, PROTECTIVE
CANOPIES AND OTHER FORMS OF PROTECTION AS REQUIRED TO PROTECT OWNER’S PERSONNEL,
BUILDING TENANTS AND THE GENERAL PUBLIC FROM INJURY DURING CONSTRUCTION.
DAMAGE REPAIR
PROMPTLY REPAIR DAMAGE WHEN OCCURS AT NO ADDITIONAL COST TO OWNER.
DUST CONTROL
USE TEMPORARY ENCLOSURES OR OTHER SUITABLE METHODS SUCH AS WATERING TO CONTROL
DUST IN ACCORDANCE WITH LOCAL JURISDICTION.
EQUIPMENT
ANY EQUIPMENT STORED ON SITE AWAITING INSTALLATION SHALL BE PROTECTED FROM PHYSICAL
DAMAGE.
POTABLE WATER SUPPLY LINE
PROPERTY LINE
LIMIT OF WORK
ACCESSIBLE PATH OF TRAVEL
ACCESSIBLE ROUTE TO PUBLIC RIGHT OF WAY
PRIMARY BUILDING ENTRANCE
SECONDARY BUILDING ENTRANCES
INTERIOR AND ROOF RENOVATION
AREA N.I.C.
AREA OF IMPROVEMENT
KEYNOTE TAGD20 / 10
3
(E) ROOF WELL AND
MECHANICAL UNIT
19' - 4"
11
'
-
8
"
WATER UTILITY
INSTALL 2 INCH BACKFLOW PREVENTION DEVICE FOR DOMESTIC PURPOSES PER
STANDARD PLAN NO. 1432. PLEASE NOTE THAT THE RESPONSIBILITY FOR
BACKFLOW DEVICE INSTALLATION AND MAINTENANCE BETWEEN TENANT AND
LANDLORD IS NOT DETERMINED BY THE CITY. THE PROPOSED BACKFLOW
DEVICE(REDUCED PRESSURE PRINCIPLE DEVICE) NEEDS TO BE INSTALLED
DIRECTLY AFTER THE WATER METER TO PROTECT THE DOMESTIC/POTABLE
WATER SERVICE PER THE STATE WATER RESOURCES CONTROL BOARD'S
CROSS-CONNECTION CONTROL POLICY HANDBOOK/REGULATIONS.
EXISTING 2" PRESSURE VACUUM BREAKER BACKFLOW DEVICE FOR PROTECTION
OF IRRIGATION SERVICE.
3
1
2
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATE OF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
US
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
2
7
/
2
0
2
6
1
0
:
1
1
:
5
8
A
M
A-010
SITE PLAN
2510
Au
t
h
o
r
1" = 20'-0"SITE PLAN 1
GENERAL NOTES
SITE LEGEND
N
(E) SITE PLAN FROM OTHER PERMIT SET. NOT TO SCALE. FOR REFERENCE ONLY
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 04/06/2026
3 PLAN RESUBMITTAL 2 04/16/2026
SITE UTILITY KEYNOTES
GENERAL NOTES
1. SEE G-SHEET SERIES FOR ADDITIONAL NOTES AND ABBREVIATIONS.
2. ALL DEMOLITION WORK SHALL COMPLY WITH LOCAL CODES AND ORDINANCES. CONTRACTOR
SHALL COMPLY WITH CITY OF ESCONDIDO WASTE MANAGEMENT PLAN REQUIREMENTS FOR
DISPOSAL AND RECYCLING OF WASTE MATERIALS.
3. CONTRACTOR SHALL MAINTAIN EXISTING UTILITIES INDICATED TO REMAIN IN SERVICE, AND
PROTECT THEM AGAINST DAMAGE DURING SELECTIVE DEMOLITION OPERATIONS.
4. CONTRACTOR SHALL PROVIDE AND MAINTAIN SHORING, BRACING, OR STRUCTURAL SUPPORT
TO PRESERVE STABILITY AND PREVENT MOVEMENT, SETTLEMENT, OR COLLAPSE OF
STRUCTURE TO REMAIN, AND TO PREVENT UNEXPECTED OR UNCONTROLLED MOVEMENT OR
COLLAPSE OF STRUCTURE BEING DEMOLISHED. CONTRACTOR SHALL STRENGTHEN OR ADD
NEW SUPPORTS WHEN REQUIRED DURING PROGRESS OF DEMOLITION.
5. CONTRACTOR SHALL PROMPTLY DISPOSE OF DEMOLISHED MATERIALS, AND SHALL NOT ALLOW
DEMOLISHED MATERIALS TO ACCUMULATE ON SITE.
6. ANY ITEMS SUSPECTED OF CONTAINING HAZARDOUS MATERIAL FOUND NOT INDICATED IN
HAZMAT INVESTIGATION REPORT SHOULD NOT BE DISTURB. IMMEDIATELY NOTIFY THE OWNER,
HAZARDOUS MATERIALS WILL BE REMOVED UNDER SEPERATE PERMIT.
7. PATCH AND REPAIR ALL EXISTING PARTITIONS AFTER DEMOLITION WHERE DAMAGE HAS
OCCURRED AT UNPROTECTED LOCATIONS. PLEASE NOTE THAT DEMOLITIONS ACTIVITY MAY
OCCUR BEYOND WORK LIMITS SHOWN ON DEMOLITION PLAN DUE TO CONCEALED CONDITIONS
8. ALL EXISTING WORK TO REMAIN UNLESS OTHERWISE NOTED.
9. WHERE EXISTING CERAMIC TILE, FABRIC OR VINYL WALL COVERING IS SCHEDULED TO BE
REMOVED, AND THE GYPSUM BOARD PAPER IS DAMAGED IN THE PROCESS, REMOVE EXISTING
LAYER OF GYPSUM BOARD TO EXPOSE EXISTING WOOD STUD FRAMING. PROVIDE NEW
GYPSUM BOARD TO MATCH EXISTING, AND AT RATED ASSEMBLIES, PROTECT AND MAINTAIN
EXISTING UL COMPONENTS AS REQUIRED TO RETAIN UL RATING.
10. PROTECT WORK AREA INCLUDING NEW AND EXISTING MATERIALS AND FINISHES FROM DAMAGE
WHICH MAY OCCUR FROM CONSTRUCTION, DEMOLITION, DUST, WATER, ETC. PROVIDE AND
MAINTAIN TEMPORARY BARRICADES, CLOSURE WALLS, AS REQUIRED TO PROTECT THE PUBLIC
AND BUILDING OCCUPANTS DURING CONSTRUCTION. DAMAGE TO NEW AND EXISTING
STRUCTURES, EQUIPMENT, MATERIALS AND FINISHES SHALL BE REPAIRED OR REPLACED TO
THE SATISFACTION OF THE OWNER AT THE SOLE EXPENSE OF THE CONTRACTOR.
11. REMOVE EXISTING FINISH MATERIALS (INCLUDING WALL FINISHES, FLOOR FINISHES, WALL
BASE, ETC) THROUGHOUT, U.O.N. PREPARE SURFACES FOR NEW FINISHES FOR ALL AREAS
AFFECTED BY THE DEMOLITION.
12. REMOVE DOORS, FRAMES, AND HARDWARE AS NOTED AND SAVE FOR REINSTALLATION U.O.N.
13. REMOVE DEMOUNTABLE PARTITIONS AS NOTED AND SAVE FOR REINSTALLATION U.O.N.
14. REMOVE AND DISCARD ALL FLOOR FINISHES AND WALL BASE AS WELL AS FLASH PATCH,
MASTIC AND ADHESIVES DOWN TO THE STRUCTURAL CONCRETE FLOOR SLAB AND PREPARE
FOR NEW FINISHES ON AREAS AFFECTED BY DEMOLITION.
15. REMOVE ALL EXISTING MATERIALS CREATING UNEVEN, OUT OF TOLERANCE SUBSTRATE
INCLUDING BUT NOT LIMITED TO FASTENERS, COVER PLATES, RESILIENT FLOORING, CARPET
PAD, ETC.
16. FOR ALL EXISTING WALLS TO REMAIN ALL CABINETRY, SIGNAGE, SHELVING, EQUIPMENT,
EXPOSED BLOCKING, TACK BOARDS, ELECTRICAL PIPING AND WALL MOUNTED ACCESSORIES,
TO BE TEMPORARILY REMOVED, PATCH , REPAIR AND PREP FOR NEW PAINTING. COORDINATE
WITH OWNER AND ARCHITECT FOR REUSE / RELOCATING OR STORING EXISTING ITEMS.
17. FOR ALL EXISTING WALL TO BE REMOVED, ANY ITEMS ON WALLS TO BE REMOVED, COORDINATE
WITH OWNER FOR REUSE / RELOCATING OR STORING EXISTING ITEMS. FOR EXISTING
ELECTRICAL EXPOSED PIPING TO BE REMOVED AND REUSE, PULL BACK, CAPPED OFF TO
ACCESSIBLE LOCATION.
18. ALL LIFE SAFETY DEVICES SHALL REMAIN ACTIVE DURING DEMOLITION AND CONSTRUCTION.
19. SAW CUT FLOOR SLAB TO RECEIVE NEW PLUMBING SCOPE.
20. COORDINATE ANY RELATED WORKS TO BE REMOVED WITH CIVIL, STRUCTURAL, MECHANICAL,
ELECTRICAL AND PLUMBING.
21. COORDINATE STORAGE, DISPOSAL, AND PARKING WITH THE CONSTRUCTION MANAGER.
NOTE:
1. SEE INTERIOR ELEVATIONS AND FINISH PLANS FOR WALL FINISH INFORMATION
2. STAGGER AND CAULK AROUND ELECTRICAL OUTLETS AND OTHER BOXES. CAULK
AROUND CONDUIT AND OTHER THROUGH-THE-WALL PENETRATIONS.
3. REFER TO STRUCTURAL X/S1.XX FOR WALL CONDITIONS AT DUCT PENETRATIONS.
4. REFER TO STRUCTURAL X/S1.XX FOR METAL STUD GA.
- ASTM E 814 OR UL 1479 "FIRE TESTS OF THROUGH-PENETRATION FIRESTOPS"
- ASTM E119 OR UL 263 "FIRE TEST OF BUILDING CONSTRUCTION AND MATERIALS"
- ASTM E 1966 OR UL 2079 "TEST FOR FIRE-RESISTANCE JOINT SYSTEMS"
FIRESTOP TEST STANDARDS IN REFERENCE TO:
DUST MITIGATION NOTES:
1. DUST CONTROL: THE GENERAL CONTRACTOR SHALL MAINTAIN CONTINUOUS
DUST ABATEMENT PROCEDURES INCLUDING TRASH REMOVAL. THE JOB SITE
SHALL BE LEFT CLEAN AND ORDERLY AT THE END OF EACH DAY.
2. CONTAIN CONSTRUCTION WASTE WITHIN DEMOLITION ZONE BEFORE
TRANSPORT IN TIGHTLY COVERED CONTAINERS.
3. REMOVE TEMPORARY WORK BARRIER / DUST CONTROLS CAREFULLY TO
MINIMIZE SPREADING DIRT AND DEBRIS ASSOCIATED WITH CONSTRUCTION.
DEMO NOTES
A1
NEW WINDOW
DOOR
AREA N.I.C.
KEYNOTE TAG
DOOR TAG
WINDOW TAG
WALL TAG
EXISTING SHEAR WALL
EXISTING WALL TO REMAIN
DEMOLISHED WALL
D20 / 10
A101
01
3 4
(E) FRONT
DOOR
3 4
240"
53
4
1
/
4
"
113 1/2"
53"
63 1/2"
83
1
/
8
"
83
1
/
8
"
82
7
/
8
"
121 1/2"
17
6
"
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATEOF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
1
6
/
2
0
2
6
2
:
1
8
:
4
6
P
M
A-100
DEMO FLOOR PLAN
2510
Au
t
h
o
r
00 DEMO WALL LEGEND1/4" = 1'-0"DEMO FIRST FLOOR PLAN 11/4" = 1'-0"FLOOR PLAN - EXISTING 2
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 04/06/2026
(N) 2X4 WOOD STUD @16" O.C. WALL - SEE DETAIL
(N) 2X6" STUD WALL @16" O.C. - SEE DETAIL
NEW WALL TYPES
EXISTING WALL TYPES
W1
W2
W3
(N) 2X6" WOOD STUD @16" O.C. INTERIOR PARTITION W/
FIRE RATED TYPE X GYP AND STAINLESS STEEL COVER -
SEE DETAIL
GRAY LINE INDICATES (E) WALLS TO REMAIN
/14 A-501
/13 A-501
/12 A-501
(N) WATER RESISTANT STUD WALL @16"
O.C. - SEE DETAIL
W4
/15 A-501
1. SEE G-SHEET SERIES FOR ADDITIONAL NOTES AND ABBREVIATIONS.
2. COORDINATE THE WORK SHOWN ON THE DRAWINGS AND IN THE PROJECT MANUAL IN ORDER TO
COMPLETE THE PROJECT AS DESIGNED.
3. ALL CONSTRUCTION IS TO COMPLY WITH THE APPLICABLE CODES AS ADAPTED BY THE REGIONAL,
STATE, AND NATIONAL AUTHORITIES HAVING JURISDICTION.
4. ALL WORK SHALL CONFORM TO CONTRACT DOCUMENTS. NO CHANGES THEREFROM SHALL BE
MADE WITHOUT WRITTEN APPROVAL OF THE ARCHITECT.
5. FIRE SAFE PENETRATIONS AT FIRE RESISTANT RATED PARTITIONS PER APPLICABLE UL ASSEMBLY.
6. PARTITIONS DIMENSIONED TO FINISH FACE U.O.N. DO NOT ADJUST DIMENSIONS INDICATED AS
“CLEAR” WITHOUT WRITTEN DIRECTION FROM ARCHITECT. DRAWINGS SHALL NOT BE SCALED.
VERIFY ALL DIMENSIONS AND EXISTING AS BUILT FIELD CONDITIONS, INCLUDING FIELD
MEASUREMENTS PRIOR TO START OF WORK, NOTIFY ARCHITECT WHERE DISCREPANCIES OCCUR.
7. PROVIDE BLOCKING AS REQUIRED AT LOCATIONS INCLUDING, BUT NOT LIMITED TO: GRAB BARS,
SHELVING, OVERHEAD CABINETS, SIGNAGE, TOILET ROOM ACCESSORIES, WALL MOUNT.
EQUIPMENT, ETC.
8. LARGE SCALE DRAWINGS TAKE PRECEDENCE OVER SMALL SCALE DRAWINGS. DETAILS TAKE
PRECEDENCE OVERALL, NOTIFY ARCHITECT IN WRITING WHERE DISCREPANCIES OCCUR.
9. PATCH FLOOR AND WALL AREAS DAMAGED DUE TO NEW CONSTRUCTION OR WHERE
PENETRATIONS HAVE BEEN MADE FOR MECHANICAL, ELECTRICAL AND PLUMBING WORK. FIRESAFE
AT UL RATED ASSEMBLIES CONSISTENT WITH EXISTING UL RATING.
10. PATCH AND REPAIR ALL EXISTING PARTITIONS AFTER DEMOLITION WHERE DAMAGE HAS OCCURRED
AT UNPROTECTED LOCATIONS. PLEASE NOTE THAT DEMOLITION ACTIVITY MAY OCCUR BEYOND
WORK LIMITS SHOWN ON DEMOLITION PLAN DUE TO CONCEALED CONDITIONS.
11. THE CONTRACTOR SHALL PROVIDE AND COORDINATE THE EXACT DIMENSIONS SIZES AND
POSITIONS OF ALL SYSTEMS, EQUIPMENT, MOUNTING, AND ATTACHMENTS RELATING TO THE WORK.
12. THE CONTRACTOR SHALL PROVIDE AND COORDINATE ALL DIMENSIONS SIZES AND POSITIONS OF
OPENINGS IN SLABS AND WALLS NECESSARY TO THE INSTALLATION OF THE WORK.
13. ALL EQUIPMENT, CONTROLS AND TERMINATIONS SHALL BE POSITIONED FOR SAFE, DIRECT AND
EASY ACCESS. REFER TO OTHER TRADES DOCUMENTS AND COORDINATE.
14. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALE UNLESS OTHERWISE NOTED BY A PLUS/MINUS
DIMENSION.
15. CONTRACTOR SHALL CHECK ACCURACY OF DIMENSIONS ON PLANS WITH ACTUAL FIELD
DIMENSIONS. THE CONTRACTOR SHALL REPORT TO THE ARCHITECT ALL CONDITIONS WHICH
PREVENT THE PROPER EXECUTION OF ITS WORK.
16. CONTRACTOR SHALL NOT START ANY CONSTRUCTION OR ANY OFF-SITE FABRICATION OF
MATERIALS UNTIL THE DRAWINGS DIMENSIONS ARE VERIFIED WITH ACTUAL FIELD CONDITIONS. DO
NOT SCALE DRAWINGS.
17. COORDINATE WITH CIVIL, LANDSCAPE, STRUCTURAL, ELECTRICAL AND MANUFACTURER FOR ANY
RELATED WORK.
(N) WATER CLOSET, PER PLUMBING
(N) URINAL, PER PLUMBING
(N) LAVATORY, PER PLUMBING
(N) MOP SINK, PER PLUMBING
FIRE EXTINGUISHER
EXISTING CONCRETE TO REMAIN
AC UNIT PER MECH.
DOWNSPOUT
ALIGN FINISHES
SERVICE LADDER
ACCESSIBLE COUNTERTOP
NEW CONCRETE
2
30" X 48" CLEAR SPACE2
?
3
A-300
59
'
-
2
"
59
'
-
2
"
WALK-IN
COOLER
60"X72"
6'
-
1
1
"
6'
-
1
1
"
25
2
1
/
2
"
44
'
-
6
"
(E) FRONT
DOOR
(E) REAR
DOOR
F.E.
499 SF
COOK
PREP
539 SF
OPEN
DINING
53 SF
RESTROOM
37 SF
STORAGE
DUAL
SWING
DOOR
SERVICE
WINDOW
FS
FD
FD
18
"
x
3
9
"
6
S
H
E
L
F
18"x39"
6 SHELF
44 3/4"
(E)ELEC
PANEL
CLEAR
1
75 3/4"
31 3/4"41 1/2"31 1/2"80 3/4"
AD
J
A
C
E
N
T
C
O
M
M
E
R
C
I
A
L
S
P
A
C
E
AD
J
A
C
E
N
T
C
O
M
M
E
R
C
I
A
L
S
P
A
C
E
20' - 0"
FS
TABLE
18"X24"
60 7/8"
A-400
6
3 4
3
3 1
2
5
1
3
A-402
7
6
A-402
9
12
11
10
W3
W-1
W4
5
A-500
6
A-501
A-400
2
FOR SINKS
SPECIFICATIONS,
REFER TO PLUMBING
DRAWINGS, TYP.
24"
20
"
TYP. SUPPLY RACK
ANCHORAGE PER
DETAIL /10 A-500
7
A-500
W1
A-400
4
3
11
A-501
1
2
3
4
5
6
7
9
10
11
12
13
14
15
17
18
30
W1
5
22
24
23
21
21
16
25
20
18"x39"
6 SHELF
OVERHEAD SHELF. FOR
MOUNTING, SEE DETAIL
/15 A-500
19
18
"
x
3
9
"
6
S
H
E
L
F
27
42
"
2
4'
-
0
7
/
8
"
2
A-401
2
4
W1
W1
W1
2
W1W4
W4
PONY
WALL
4
PROVIDE "ALL GENDER"
RESTROOM SIGNAGE ON
DOOR PER /6 G-142
2
A-400
11
APPROVAL FOR COOLER COMPONENTS:
WALL AND CEILING PANELS -ESR-3775
FOAM INSULATION -ESR-2142
DOOR AND HARDWARE -UL-471 3
STAINLESS STEEL RACK 1: 18" X 39" X (6 TIER SHELVING) = 19.5 RUNNING FT
STAINLESS STEEL RACK 2: 18" X 39" X (6 TIER SHELVING) = 19.5 RUNNING FT
STAINLESS STEEL RACK 3: 18" X 39" X (6 TIER SHELVING) = 19.5 RUNNING FT
STAINLESS STEEL RACK 4: 18" X 39" X (6 TIER SHELVING) = 19.5 RUNNING FT
FRONT DESK SHELVING: 18" X 12' (2 TIER SHELVING)= 24' RUNNING FT
TOTAL DRY FOOD STORAGE SPACE = 102'-0" RUNNING FT.
NOTE
AT LEAST 50% OF THE MINIMUM REQUIRED SHELVING BE
READILY ACCESSIBLE TO THE STAFF .
FOOD PREP
RAW FOOD
STORAGE
DRY FOOD
STORAGE
WARE WASHING
DELIVERY
FOOD SERVED
ZONE 1
ZONE 3
ZONE 2
ZONE 4
ZONE 5
ZONE 6
FRONT DESK
SHELVING
QTY MAKE
PHASE
ELECTRICAL
NEW1
NOTES
GAS / BTU
PER HR
PLUMBING
MODEL LISTING /
APPROVAL
(E)
/
(N)
EQ#
AMPSWATTS HOT
WATER
COLD
WATER
01 CAPTIVEAIRE ND-2 SERIES 16 FT UL 710, NFPA - - - - - -INCLUDE FIRE SUPPRESSION
SYSTEM AND ALARM
EXIST102 VERIFY IN FIELD VERIFY IN FIELD - - 100A 3 PH - - -
ELECTRICIAN TO VERIFY CONDITION
OF (E) PANEL PRIOR TO CONNECTING
ALL EQUIPMENT
NEW203 COOLER DEPOT HT-L-6 NSF - - - - - -LEGS TO BE ROUND AND 6"
MIN. HEIGHT
NEW104 STEELTON
#522MS242412
24"X24"X12" 18 GAUGE
304 SS
NSF - - - YES YES -INCLUDE VACUUM BREAKER
AT FAUCET
NEW105 SCHWANK BREEZE9 AC-1048-12-BK UL507 530 W 4.5 A 1 PH - - -PROVIDE SENSOR FOR WHEN
STAFF DOOR IS OPEN
NEW106 OMCAN
#43789, 18-GA 304 SS,
CENTER DRAINS AND 4
FAUCET HOLES
NSF - - - YES YES -
PROVIDE 22" W LEFT AND RIGHT
DRAIN BOARDS. PROVIDE 6" SPLASH
GUARD BOTH SIDES
NEW107 TOAST TOAST FLEX W/
TOUCH PAD N/A 60 W 0.5 A 1 PH - - -
MODEL PROVIDED FOR PLANNING
PURPOSES. EXACT MODEL SUBJECT
TO CHANGE PER OWNER
NEW108 CAPTIVEAIRE INLINE3-24D SUPPLY
UNIT
UL705, CSA
STD. C22.2 3,730 W 12 A 3 PH.
208V - -12,730
BTU/HR -
NEW110 DUKERS APPLIANCE
CO.DCR60-6B24GM NSF / ANSI 2 - -1 PH,
120V - -278,000
BTU/HR
3/4” NPT REAR GAS
CONNECTION
NEW109 CHEF AAA ICE-O-MATIC
ICEU220K NSF, ETL 526 W 4.8 A 1 PH - YES 1,796
BTU/HR -
NEW111 MIGALI C-U48F-HC ETL 747 W 6.5 A 1 PH,
120V - -2,547
BTU/HR R290 REFRIGERANT
NEW112 DUKERS DCF3-NG CSA - - - - -NATURAL GAS,
90,000 BTU/HR
4" GAS LINE CONNECT, 40 LB OIL
TANK CAPACITY FOR HIGH-VOLUME
FRYING
NEW113 MIGALI C-2FB-HC ETL, ISO 9000 1,380 W 12 A 1 PH,
120V - -4,709
BTU/HR R290 REFRIGERANT
NEW114 OMCAN USA 48000 (CE-CN-0022-NG) ETL - - - - -NATURAL GAS,
140,000 BTU/HR
70,000 BTU; 1/2" GAS
CONNECTION
NEW115 AMERIKOOLER QC060872 - NBSC (96″ W
× 72″ D × 86.25″ H)UL 471, NSF 2,800 W 9 A 1 PH,
120V - - -ACRYLUME METAL FINISH ON INSIDE
AND OUTSIDE. SEE MECHANICAL
NEW116 DUKERS DCSPA1 + DCSPA2 ETL - - - - -NATURAL GAS,
80,000 BTU/HR 3/4” NPT REAR GAS CONNECTION
NEW117 OMCAN USA 43772 ONE TUB POT
SINK CSA - - - - - -3.5″ CENTER DRAIN. PROVIDE
6" SPLASH GUARD LEFT SIDE
NEW118 CHAMPION
INDUSTRIES
UL-130 LOW TEMP
U/C DISHWASHER UL-130 1,380 W 12 A 1 PH,
120V - - -21 RACKS. PROVIDE
CLEANABLE BASE
NEW119 MIGALI C-U48R-HC ETL, ENERGY
STAR 402 W 3.5 A 1 PH,
120V - -1,372
BTU/HR
R290 REFRIGERANT, 12 CU FT
INTERIOR SPACE
NEW120 NOT USED NOT USED - - - - - - - -
NEW221 OMCAN USA 44586 NSF, CSA - - - YES YES -
PROVIDE 6" SPLASH GUARD BOTH
SIDES. INCLUDE FABRICATED HAND
SINK FAUCET
NEW122 KUARBARR 12"D x 30"W x 33"H NSF - - - - - -PROVIDE CASTERS WITH
LOCKING OPTIONS
NEW223 REGENCY SW1860-3-16-V 16
GAUGE STAINLESS STEEL NSF - - - - - - -
NEW124 2507B TRAPPER - N/A N/A N/A - - - 8 D-CELL BATTERY POWEREDDEMA
NEW125 5624704 - 3M WATER
FILTRATION
NSF 42
NSF 53
NSF 372
- - - NO YES -WALL MOUNTED. 125 PSI
MAX. 3/4" WATER CONNECT.SOLVENTUM
NEW226 NPE-240A2 / S2 NSF 5, CSA,
SCAQMD 240 W 2 A 1 PH,
120V YES YES NATURAL GAS,
199,900 BTU/HR
3/4″ NPT GAS AND WATER IN/OUT
STANDARD. CONDENSATE LINE TO
FLOOR SINK BELOW. SEE PLUMBING
NAVIEN
DRAIN
-
-
-
DIRECT
-
INDIRECT
-
-
-
INDIRECT
-
-
-
-
INDIRECT
-
DIRECT
DIRECT
-
-
-
-
-
INDIRECT
-
INDIRECT
EQUIP.
TYPE 1 VENTED
HOOD
ELECTRIC
PANEL
STAFF
LOCKERS
MOP FLOOR
SINK
AIR CURTAIN
3 COMP. SINK
POINT OF SALE
AND REGISTER
MAKE-UP AIR
SYSTEM
COMBINATION
GAS RANGE
ICE MAKER
AND BIN
LOW FREEZER
2 DOOR W/
PREP TABLE
FRYER W/
THREE TUBE
BURNER
2 DOOR FH
REFRIGERATOR
GAS PASTA
COOKER
WALK IN
COOLER
STOCK POT
COMBO
RANGE
FOOD PREP
SINK
DISHWASHER
LOW REFRIG.
2 DOOR W/
PREP TABLE
MERCH
REFRIGERATOR
HANDWASH
SINK
SS TABLE
SS WALL
SHELF
CHEMICAL
DISPENSER
WATER
FILTRATION
SYSTEM
TANKLESS HOT
WATER HEATER
NEW127 LUCERNE
MODEL 0355034.020 ANSI A112 - - - YES YES - WALL HUNGAMERICAN
STANDARD -LAVATORY
NEW128 DIRECT UPBLAST
SYSTEM - DU-HFA UL-762 1200 W 6 A 3 PH
(230V)- - -
FAN MOTOR TO REACH 5,000
CFM MIN. FOR 100%
COVERAGE OF SYSTEM AIR
CAPTIVEAIRE
EXHAUST FAN -EXHAUST FAN
VENTED HOOD
NEW129 SUI-9913-CX SUI
SERIES ETL - - - - - -
VERTICAL LIFT TRANSACTION
WINDOW MANUAL 24" W X
48" H CLEAR ANODIZED
QUIKSERV -SERVICE
WINDOW
NEW130 XST-48-18-N ETL - 3 A 1 PH,
120V - -3,400
BTU/HR R290 REFRIGERANTREFRIGERATION X -2 DOOR FOOD
PREP TABLE
1
1
1
2
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATEOF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
1
6
/
2
0
2
6
2
:
1
8
:
4
8
P
M
A-200
FLOOR PLAN
2510
Au
t
h
o
r
NEW WALL LEGEND
GENERAL NOTES
FLOOR PLAN LEGEND
1/4" = 1'-0"FLOOR PLAN - NEW 1
DRY FOOD STORAGE CALCULATION
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
1 PLAN RESUBMITTAL 01/16/2026
B HEALTH SUB 2 02/04/2026
C HEALTH SUB 3 02/25/2026
D HEALTH SUB 4 03/06/2026
2 PLAN RESUBMITTAL 04/06/2026
3 PLAN RESUBMITTAL 2 04/16/2026
COLORED ZONING PLAN
1
EQUIPMENT SCHEDULE
PAINT
PT
VENDOR: DUNN EDWARDS
ID: DEW380 RL#005
COLOR: WHITE
FINISH: SEMI-GLOSS PAINT, 2 COAT MIN. EACH LOCATION
CET VENDOR: ARMSTRONG
STYLE: CLEAN ROOM "VL" 870
COLOR: WHITE
SIZE: 2'X4'
GRID: HEAVY DUTY PRELUDE XL
SUSPENDED CEILING TILE 2'X4'
VENDOR: DALTILE
ITEM: 6" X 6" SQUARE FLOOR AND WALL TILE - 0Q4066F1A
COLOR: RED BLAZE - 4124
TEXTURE: MATTE
THICKNESS: 1/2"
QUARRY TILE
QT
P = PAINT
B = BASE
PL = PLASTIC LAMINATE
C = CARPET
WD = WOOD
ST = STONE
SDT = STATIC DISSIPATIVE TILE
FT = FLOOR TRANSITION
CT = CERAMIC TILE
G = GROUT
RF = RESILIENT FLOORING
GL = GLASS
MTL = METAL
SSM = SOLID SURFACE
WT = WINDOW TREATMENT
FAB = FABRIC
WC = WALL COVERING
ACP = ACOUSTICAL CEILING PANEL
CON = CONCRETE
ANNOTATIONS AND DEFINITIONS
1. USE PL-1, PLASTIC LAMINATE FOR LOWER CASEWORK U.N.O.
2. USE PL- 2, PLASTIC LAMINATE FOR UPPER CABINET U.N.O.
3. USE HAFELE# 115..21.002 IN A STAINLESS STEEL FINISH FOR HARDWARE
PULLS OF CASEWORK, U.N.O. REFER TO SPECIFICATION FOR ADDITIONAL
HARDWARE INFORMATION.
064100 ARCHITECTURAL WOOD
PLASTIC AND COMPOSITE
1. REFER TO THE REFLECTED CEILING PLANS FOR ACOUSTICAL CEILING TILE
LOCATIONS AND EXTENTS.
2. ACOUSTICAL CEILING PANELS TO BE SMOOTH EASILY CLEANABLE W/O
PERFORATIONS OR FISSURES PER TABLE CBC 1224.1.11
095110 ACOUSTICAL PANEL CEILINGS
SEALED CONCRETE FLOORING
CF
VENDOR: GLAZE N' SEAL
STYLE: MULTI PURPOSE SEALER
COLOR: CLEAR
FINISH: MATTE
CONTACT: (949) 250-9104
OCHCA: PER APPROVED LIST
A. EXISTING CONCRETE SLAB SHALL BE
MECHANICALLY GROUND AND
POLISHED TO ACHIEVE UNIFORM,
DENSE SURFACE.
B. FINISH LEVEL: CLASS B MEDIUM
POLISH (800-GRIT MINIMUM) OR AS
NEEDED TO MATCH AESTHETIC AND
PERFORMANCE.
NOTE:
C. WATER-BASED, LOW VOC,
COMPATIBLE WITH POLISHED
CONCRETE FINISH.
D. MUST ACHIEVE MINIMUM DCOF =
0.42 WET, VERIFIED BY MANUF.
E. TRANSPARENT FINISH; SHEEN LEVEL
COMPATIBLE WITH 800–1500 GRIT
POLISHING.
CTP VENDOR: SOLID SURFACE
STYLE: LG HI-MACS
COLOR: EBONY CONCRETE
FINISH: SMOOTH
COUNTERTOP TILE
BV VENDOR: BELDEN BRICK
STYLE: MODULAR 503 - 505
COLOR: RED
FINISH: SMOOTH
MASONRY VENEER
VENDOR: DALTILE
ITEM: 6" X 6" COLOR WHEEL CLASSIC
COLOR: BLACK
TEXTURE: MATTE
THICKNESS: 1/2"
CONTACT: 1-877-426-1500
CERAMIC TILE
CT
FRP COVER
FRP
VENDOR: GLASLINER
SIZE: 0.090 IN. X 4 FT. X 8 FT.
ID: DEW380 RL#005
COLOR: WHITE FRP
FINISH: DECORATIVE WALL
CEILING
WALL
FLOOR
BASE
GYPSUM DRY WALL CEILING WITH PAINT
SEMI GLOSS ENAMEL PAINT, WASHABLE, SMOOTH, SEE TO NOTE #1
USG SHEETROCK FIRECODE TYPE X WITH PAINT, SEE NOTE #1
T BAR LAY-IN CEILING PANEL, 2X2 OR 2X4
METAL GALVANIZED PANEL, WASHABLE, SMOOTH
GYPSUM DRY WALL WITH PAINT
SEMI GLOSS ENAMEL PAINT, WASHABLE, SMOOTH - SEE NOTE #1
EXPOSED CEILING
NON ABSORBENT RESISTANT WALL FINISH, 48" HIGH MIN.
WALL COVERING WITH FRP OR CERAMIC TILE (LIGHT COLOR) 48" HIGH MIN.
WALL COVERING WITH STAINLESS STEEL 48" HIGH MIN.
1. ALL WALL AND CEILING IN ALL STAFF
AREAS SHALL BE SMOOTH, WASHABLE,
DURABLE, NON ABSORBENT, AND EASILY
CLEANABLE WITH A LIGHT COLORED
(HAVING A LIGHT REFLECTANCE OF 70%
OR GREATER) USE MRGB BACKING FOR
WAINSCOT.
2. ALL FLOOR TILE TO BE DURABLE, NON
ABSORBENT, AND EASILY WASHABLE.
3. FLOORING UNDER EQUIPMENT AND AT
THE BASE COVES SHALL BE COMPLETELY
SMOOTH, FLOOR SURFACES WHICH
CONTAIN SLIP RESISTANT AGENTS SHALL
BE RESTRICTED TO TRAFFICKED AREAS
ONLY.
4. ALL COUNTER SURFACE INCLUDING
UNDERSIDE TO BE DURABLE, SMOOTH,
NON ABSORBENT, EASILY CLEANABLE,
AND WASHABLE FINISH. MAY REQUIRE
STAINLESS STEEL OR NSF APPROVED
HIGH PRESSURE LAMINATE.
5. FLOOR SMOOTHED CONCRETE MUST BE
TOP-SET TYPE CERAMIC COVED BASE.
THE APPROVED MATERIAL: B&W TILE CO.
#S-3619T. AND THE APPROVED CONCRETE
SEALER MATERIAL: AQUA MIX SEALER'S
CHOICE GOLD.
6. IF USING SHEET VINYL, THE APPROVED
MATERIAL: USG SHEETROCK FIRECODE
TYPE X
7. ALL EQUIPMENT SHALL BE EASILY
MOVABLE (I.E. ON CASTERS) OR MIN. 6"
ROUNDED METAL LEGS, OR SEALED TO
MIN. TO MIN. 4" SOLID MASONRY ISLAND
WITH MIN. 3/8" COVED BASE.
8. A MIN. 50 FOOT-CANDLE OF LIGHT
MEASURED 30" A.F.F. IN KITCHEN, WARE
WASHING, SERVICE AREA, THROUGHOUT
FACILITY FOR GENERAL CLEANING ACTIVITY
AND A MIN. 10 FOOT-CANDLE OF LIGHT
MEASURED 30" A.F.F. IN RESTROOM AND
STORAGE AREAS.
FINISHES RO
OMS
KITC
HEN
A
R
EA
HALL
W
A
Y
STORAGE
AREA
RESTROOM
OPEN
D
I
N
I
NG
METAL GALVANIZED PANEL, WASHABLE, SMOOTH
QUARRY TILE - SEE NOTES #2, #3, #4
CERAMIC TILE, NON-SLIP. SEE NOTES #2, #3
CARPETED OR WOODEN FLOOR
VINYL TILE 12"X12"
SHEET VINYL FLOOR - SEE NOTE #6
SMOOTH CONCRETE FL. W/ SEALER, SEE NOTE #5
QUARRY TILE - SEE NOTES #2, #3, #4
CERAMIC TILE 6" HIGH MIN. - CONTINUOUS
CERAMICTILE 6" HIGH MIN. - SMOOTH
CERAMIC TILE 6" HIGH MIN. - SLIM FOOT
RUBBER 4" MIN.
PROVIDE 3/8" RADIUS COVE
METAL FLOOR WITH SURETREAD FINISH - FOR WALK-IN REF
MASONRY VENEER
COMMENTS
1
MOP
S
I
N
K
SEE PLANS FOR
SPECIFIC
LOCATIONS OF
MATERIAL
FINISHES FOR EQUIP. AT HOOD
3 4
WALK-IN REFRIGERATOR
FINISHES BASED ON
CUTSHEETS. SEE SHEET M-104
CTP
BV
CF
QT
CF
QT
PT
PT
PT
PT
PT
FRP
FRP
STAINLESS STEEL,
ONE SIDE-SEE
WALL DETAILS
OPEN DINING
AREA
KITCHEN
AREA
REST
ROOM
STORAGE
HA
L
L
W
A
Y
FRP
PT
CF
SL
SL
SL
.CET
OVERHEAD
CT
CT
FRP
P1
FRP
FRP ABOVE TILE - SEE
INTERIOR ELEVATIONS
PT
PT
FRP
EXPOSED CEILING
ABOVE - NO FINISH
BV
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATEOF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
1
6
/
2
0
2
6
2
:
1
8
:
4
8
P
M
A-201
FINISH FLOOR PLAN
2510
Au
t
h
o
r
FINISH LEGENDFINISH SCHEDULE
1/4" = 1'-0"FLOOR FINISH PLAN 1
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
1 PLAN RESUBMITTAL 01/16/2026
B HEALTH SUB 2 02/04/2026
C HEALTH SUB 3 02/25/2026
2 PLAN RESUBMITTAL 04/06/2026
NOTE:
STAINLESS STEEL TO
ONLY BE PROVIDED AT
WALL WITH HEAT
GENERATING EQUIPMENT.
ALL OTHER WALLS REFER
TO THE FINISH SCHEDULE.
1
FOR THE WALK-IN COOLER -REFER TO MECHANICAL CUTSHEETS ON THE SELECTED FINISHES AND SPECIFICATIONS.1
-4"
539 SF
OPEN
DINING
499 SF
COOK
PREP
53 SF
RESTROOM
37 SF
STORAGE
8'-0"
3 4
240"
28
1
3
/
4
"
82
7
/
8
"
83
1
/
8
"
4
A-500
PENDANT LIGHT FIXTURE,
REFER TO ELECTRICAL, TYP.
FOR LIGHT FIXTURE
INFORMATION, REFER TO
ELECTRICAL, TYP.
FOR HOOD SPECIFICATIONS,
REFER TO MECHANICAL
11
A-500
18
A-500
18
A-500
(E) ROOFTOP
MECH. UNIT
ABOVE
FOR SUPPLY/RETURN
INFORMATION, REFER TO
MECHANICAL
POSITION OF
OVERHEAD (E)
ROOF WELL
16
'
-
0
"
/3 A-210
OPENING ABOVE WALK-IN
COOLER
(E) OR (N) WALL PER PLAN
PLAN KEYNOTES
(E) GYPSUM BOARD CEILING TO REMAIN,
PROTECT IN PLACE
SUPPLY/RETURN AIR REGISTER,
REFER TO MECHANICAL DRAWINGS
LIGHT FIXTURE,
REFER TO ELECTRICAL DRAWINGS
2X4 SUSPENSION T-BAR CEILING GRID WITH WASHABLE
ACOUSTIC CEILING TILE PER DETAIL
REFER TO SPECIFICATION
EXIT SIGN TO ELECTRICAL DRAWINGS
10'-0"CEILING HEIGHT ABOVE FINISH FLOOR
ROOM NUMBER
GYPSUM BOARD CEILING
PER DETAIL
(E) COOLER/FREEZER ENCLOSURE CEILING,
PROTECT IN PLACE
2X2 SUSPENSION T-BAR CEILING GRID WITH WASHABLE
ACOUSTIC CEILING TILE PER DETAIL
REFER TO SPECIFICATION
1
(E) PLASTER CEILING TO REMAIN, PROTECT IN PLACE.
PATCH AND REPAIR CRACKS 3/8" WIDE AND OVER TO
MATCH EXISTING SOFFIT FINISH. PAINT TO MATCH
EXISTING COLOR
CEILING MOUNTED ONE SIDED EXIT SIGN
CEILING MOUNTED TWO SIDED EXIT SIGN
WALL MOUNTED EXIT SIGN
LINEAR FLUORESCENT
TYP. CEILING GRID AND
LIGHT FIXTURE
AREA NOT IN SCOPE
INDICATES MOUNTING HEIGHT +80
LINEAR FLUORESCENT WALL WASHER
CEILING MOUNTED SPECIALTY PENDANT
DENOTES EXISTING TO REMAIN
DENOTES RELOCATED
(E)
(R)
123 #
1. FOR CEILING DETAILS, SEE THE A 500 SERIES SHEETS
2. FOR EXTERIOR WALL MOUNTED LIGHTING FIXTURES, SEE EXTERIOR ELEVATIONS FOR TYPES AND
DIMENSIONS.
3. THIS PLAN HAS BEEN COORDINATED WITH THE MOST CURRENT ELECTRICAL, MECHANICAL AND
PLUMBING PLANS. ADJUSTMENTS MAY BE REQUIRED DURING CONSTRUCTION TO DEAL WITH
UNFORESEEN CONFLICTS THAT OCCUR. PRIOR TO PLACEMENT OF NAY ITEM ON THE CEILING
PLANS THAT IS NOT SHOWN OR DOES NOT AGREE WITH THIS PLAN, ASK FOR CLARIFICATION FROM
THE ARCHITECT. DROPPED CEILING FRAMING SHALL LAYOUT TO COORDINATE WITH ALL REQUIRED
CEILING ITEMS.
4. ALL CEILING HEIGHTS ARE CLEAR DIMENSIONS AND SHALL BE ADJUSTED TO ACCOUNT FOR
VARIATIONS IN TEXTURE AND PATTERNS.
5. WHERE LIGHT FIXTURES AND/OR OTHER DEVICES ARE GRAPHICALLY REPRESENTED AS BEING
LOCATED IN THE CENTER OF A CEILING TILE, WHETHER DIMENSIONED OR NOT, THE CONTRACTOR
SHALL LOCATE THE LIGHT FIXTURE, SPRINKLERS, OR DEVICE EXACTLY IN THE CENTER OF THE
TILE.
6. ALL MECHANICAL AND ELECTRICAL ROOMS TO MEET MINIMUM FOOT CANDLE REQUIREMENTS AND
SHALL LOCATE LIGHTS RELATIVE TO EQUIPMENT LOCATION.
7. ALL EXTERIOR EXPOSED UTILITY SUPPORTS TO BE GALVANIZED FINISH OR PAINTED.
8. REFER TO THE ELECTRICAL DOCUMENTS FOR SPECIFIC INFORMATION REGARDING LIGHT
FIXTURES AND OTHER ELECTRICAL DEVICES SHOWN ON THIS SHEET, WHETHER THE LIGHT
FIXTURE OR DEVICE IS RECESSED OR SURFACE MOUNTED.
9. REFER TO THE MECHANICAL DOCUMENTS FOR SPECIFIC INFORMATION REGARDING THE AIR
REGISTERS, DIFFUSERS AND EXHAUST VENTS.
10. ADDITIONAL CEILING ACCESS PANELS MAY BE CALLED FOR BY THE MECHANICAL, PLUMBING,
AND/OR ELECTRICAL DOCUMENTS, AND MAY NOT BE SHOWN ON THE REFLECTED CEILING PLANS.
IN THIS EVENT, THE CONTRACTOR SHALL CONFIRM THE LOCATION OF THE ACCESS PANEL WITH
THE ARCHITECT OF RECORD PRIOR TO PROCEEDING WITH THE CEILING WORK.
11. IN THE EVENT OF A CONFLICT BETWEEN THE REFLECTED CEILING PLAN AND THE
CORRESPONDING DOCUMENTS OF THE OTHER DISCIPLINES, THE CONTRACTOR SHALL BRING THE
CONFLICT TO THE ATTENTION OF THE ARCHITECT OF RECORD FOR CLARIFICATION PRIOR TO
PROCEEDING WITH THE WORK.
3 4
539 SF
OPEN
DINING
499 SF
COOK
PREP
53 SF
RESTROOM
37 SF
STORAGE
2x8 WD
2x8 WD2x8 WD
2x8 WD
2x
8
W
D
2x
8
W
D
SISTER JOIST 2X8
TY
P
.
24
"
O
.
C
.
10' - 8"9' - 4"
9' - 4"
9' - 4"
9' - 4"
W-1
W1W1W3
W4
(N) 2X4 WOOD STUD @16" O.C. WALL - SEE DETAIL
(N) 2X6" STUD WALL @16" O.C. - SEE DETAIL
NEW WALL TYPES
EXISTING WALL TYPES
W1
W2
W3
(N) 2X6" WOOD STUD @16" O.C. INTERIOR PARTITION W/
FIRE RATED TYPE X GYP AND STAINLESS STEEL COVER -
SEE DETAIL
GRAY LINE INDICATES (E) WALLS TO REMAIN
/14 A-501
/13 A-501
/12 A-501
(N) WATER RESISTANT STUD WALL @16"
O.C. - SEE DETAIL
W4
/15 A-501
3 4
(E
)
R
O
O
F
S
L
O
P
E
(E
)
R
O
O
F
S
L
O
P
E
(E) ROOF WELL
(E) 4 TON RTU -
NOT IN SCOPE
(E) CLERESTORY
WINDOW TO REMAIN
(E) VENT STACK
(E) FLUE VENT
(E) 4 TON RTU. TO
REMAIN, PROTECT
IN PLACE
(N) MAKE UP AIR
SYSTEM - SEE
MECH. CUTSHEETS
FOR SPECIFICATION
18' - 10"
(N) (2) TANKLESS WATER
HEATERS - SEE PLUMBING
11
'
-
5
"
(E) ACCESS
LADDER
(E) ROOF DRAIN
(E) OVERFLOW
DRAIN
8
FOR CASCADING
TANKLESS WATER
HEATER CONNECT,
SEE PLUMBING
DETAILS SHEET
8
31
ROOF
10' -0"
2'
-
6
"
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATEOF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
1
6
/
2
0
2
6
2
:
1
8
:
4
9
P
M
A-210
RCP AND ROOF PLAN
2510
Au
t
h
o
r
1/4" = 1'-0"REFLECTED CEILING PLAN 1
LEGEND - RCP
GENERAL NOTES - RCP
1/4" = 1'-0"ROOF PLAN 3 1/4" = 1'-0"ROOF FRAMING PLAN 2
NEW WALL LEGEND
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
C HEALTH SUB 3 02/25/2026
2 PLAN RESUBMITTAL 04/06/2026
1/4" = 1'-0"ROOF WELL ELEVATION 4
FIRST FLOOR
0' -0"
ROOF
10' -0"
CEILING
9' -4"
3
A-300
3 4
FIRST FLOOR
0' -0"
ROOF
10' -0"
CEILING
9' -4"
IN
T
.
T
O
P
O
F
R
I
D
G
E
19
'
-
5
"
2
FIRST FLOOR
0' -0"
ROOF
10' -0"
CEILING
9' -4"
OPEN
DINING COOK
PREP
RESTROOM
STORAGE
TO
P
O
F
S
T
U
D
W
A
L
L
18
'
-
0
"
TO
P
O
F
S
T
U
D
W
A
L
L
15
'
-
9
"
TO
P
O
F
(
E
)
S
T
U
D
W
A
L
L
12
'
-
0
"
2
2
STUD SIZE
(INCHES)
2 X 3
TABLE 2308.9.1
SIZE, HEIGHT, AND SPACING OF WOOD STUDS
BEARING WALLS NONBEARING WALLS
LATERALLY
UNSUPPORTED
STUD HEIGHT
(FEET)
SUPPORTING ROOF
AND CEILING ONLY
SUPPORTING ONE
FLOOR, ROOF AND
CEILING
SUPPORTING
TWO FLOORS,
ROOF AND
CEILING
LATERALLY
UNSUPPORTED
STUD HEIGHT
(FEET)
SPACING
(INCHES)
SPACING (INCHES)
2 X 4
3 X 4
2 X 5
2 X 6
-
10
10
10
10
-
24
24
24
24
-
16
24
24
24
-
-
16
-
16
10
14
14
16
20
16
24
24
24
24
FOR SI, 1 INCH = 25.4 MM, 1 FOOT = 304.8MM
a. LISTED HEIGHTS ARE DISTANCES BETWEEN POINTS OF LATERAL SUPPORT PLACED PERPENDICULAR
TO THE PLANE OF THE WALL. INCREASES IN UNSUPPORTED HEIGHT ARE PERMITTED WHERE
JUSTIFIED BY AN ANALYSIS.
b. SHALL NOT BE USED FOR EXTERIOR WALLS
b
a a
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATEOF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
1
6
/
2
0
2
6
2
:
1
8
:
5
1
P
M
A-300
SECTIONS
2510
Au
t
h
o
r
1/4" = 1'-0"1 CROSS SECTION
1/4" = 1'-0"2 SECTION - OPEN DINING
1/4" = 1'-0"3 SECTION - KITCHEN
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 04/06/2026
2
FIRST FLOOR
0' -0"
ROOF
10' -0"CEILING
9' -4"
2
A-30034
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATEOF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
1
6
/
2
0
2
6
2
:
1
8
:
5
2
P
M
A-310
EXTERIOR ELEVATIONS
2510
Au
t
h
o
r
1/4" = 1'-0"2
SCHEMATIC DESIGN - NORTH
ELEVATION
1 ENTRY - 3D VIEW
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 04/06/2026
1/2" = 1'-0"3 Elevation 4 - a
1
8'
-
0
"
7' - 9 5/8"
1
11
2'
-
0
"
6'
-
0
"
1
2'
-
0
"
6'
-
0
"
6' - 10 7/8"
7 8'
-
0
"
8 11
42"
8"
12
19
"
M
A
X
.
MA
X
.
48
"
34
"
6'
-
0
"
2'
-
0
"
8'
-
0
"
7' - 9 5/8"
1
3 542
67
11
36"
19" MAX
17" MIN
19" MAX
17" MIN
1
6' - 10 7/8"
8'
-
0
"
2'
-
0
"
6'
-
0
"
11
WALL MOUNTED SOAP DISPENSER
1
WALL MOUNTED PAPER TOWEL DISPENSER2
WALL MOUNTED MIRROR3
WALL MOUNTED HAND WASHING SINK4
6'-0" HEIGHT WALL TILE
5
FLOOR MOUNTED ACCESSIBLE WATER CLOSET6
ACCESSIBLE GRAB BAR7
BOBRICK B-35745 TOILET PAPER AND SEAT COVER DISPENSER8
6" SLIMFIT COVE9
COVED TILE, SEE ARCH DETAILS10
FRP WALL COVERING, SEE FINISH SCHEDULE11
TOILET PAPER HOLDER12
4
SNEEZE
GUARD
93"
ACCESSIBLE
COUNTERTOP
HEIGHT
LIGHTING PER
ELECTRICAL, TYP.
32
"
38
"
36
"
80
"
M
I
N
.
6'
-
2
"
1 2
2
8' - 0"5' - 0"
4" TOE
CLEARANCE3
5' - 0" 7' - 11 1/2"
42
"
5' - 0" 7' - 11 1/2"
7' - 9"
FORMICA SHELVING.
KEEP CLEAN, SMOOTH,
AND DURABLE
PROVIDE COVE AT
BASE PER DETAIL
12
"
4
"
12
"
5
1
/
2
"
2
NOTE: PENDANT
LIGHT TO NOT
EXTEND DIRECTLY
ABOVE THE COUNTER
24" 41 1/2" 19 1/2"
4"
12
"
3'
-
2
"
12
"
FORMICA SHELVING.
KEEP CLEAN, SMOOTH,
AND DURABLE
PROVIDE COVE AT
BASE PER DETAIL
A-400
8
9
10
7
7' - 10"
6'
-
1
1
"
60"
5"
1' - 6"
36"
42
"
1' - 6"
FD
3'
-
6
"
2'
-
8
"
6'
-
2
"
5' - 0 1/2"2' - 1"
38"
30
"
48"
60"
3
1
/
2
"
11B-904.4 SALES AND SERVICE COUNTERS
SALES COUNTERS AND SERVICE COUNTERS
SHALL COMPLY WITH SECTION 11B-904.4.1 OR
11B-904.4.2. THE ACCESSIBLE PORTION OF THE
COUNTERTOP SHALL EXTEND THE SAME
DEPTH AS THE SALES OR SERVICE
COUNTERTOP.
EXCEPTION:
IN ALTERATIONS, WHEN THE PROVISION OF A
COUNTER COMPLYING WITH SECTION
11B-904.4 WOULD RESULT IN A REDUCTION OF
THE NUMBER OF EXISTING COUNTERS AT
WORK STATIONS OR A REDUCTION OF THE
NUMBER OF EXISTING MAIL BOXES, THE
COUNTER SHALL BE PERMITTED TO HAVE A
PORTION WHICH IS 24 INCHES (610 MM) LONG
MINIMUM COMPLYING WITH SECTION
11B-904.4.1 PROVIDED THAT THE REQUIRED
CLEAR FLOOR OR GROUND SPACE IS
CENTERED ON THE ACCESSIBLE LENGTH OF
THE COUNTER.FIGURE 11B-904.4 (EXCEPTION)
ALTERATION OF SALES AND SERVICE
COUNTERS
11B-904.4.1 PARALLEL APPROACH
A PORTION OF THE COUNTER SURFACE THAT
IS 36 INCHES (914 MM) LONG MINIMUM AND 34
INCHES (864 MM) HIGH MAXIMUM ABOVE THE
FINISH FLOOR SHALL BE PROVIDED. A CLEAR
FLOOR OR GROUND SPACE COMPLYING WITH
SECTION 11B-305 SHALL BE POSITIONED FOR A
PARALLEL APPROACH ADJACENT TO THE 36
INCH (914 MM) MINIMUM LENGTH OF COUNTER.
EXCEPTION:
WHERE THE PROVIDED COUNTER SURFACE IS
LESS THAN 36 INCHES (914 MM) LONG, THE
ENTIRE COUNTER SURFACE SHALL BE 34
INCHES (864 MM) HIGH MAXIMUM ABOVE THE
FINISH FLOOR.
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATEOF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
1
6
/
2
0
2
6
2
:
1
9
:
0
9
P
M
A-400
ENLARGED PLANS
2510
Au
t
h
o
r
1/2" = 1'-0"RESTROOM - SOUTH 81/2" = 1'-0"RESTROOM - EAST 91/2" = 1'-0"RESTROOM - NORTH 10 1/2" = 1'-0"RESTROOM - WEST 7
1/4" = 1'-0"FRONT COUNTER ELEVATION 2
1/2" = 1'-0"ENLARGED RESTROOM PLAN 6
INTERIOR ELEVATION KEYNOTES
1/4" = 1'-0"BEHIND THE COUNTER ELEVATION 4 1/4" = 1'-0"EAST COUNTER ELEVATION 3 FRONT OF HOUSE - ISO 3D 1
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
1 PLAN RESUBMITTAL 01/16/2026
B HEALTH SUB 2 02/04/2026
C HEALTH SUB 3 02/25/2026
2 PLAN RESUBMITTAL 04/06/2026
3 PLAN RESUBMITTAL 2 04/16/2026
1/4" = 1'-0"WEST COUNTER ELEVATION 5
1
1
NOTE:
DOOR IN ANY POSITION SHALL NOT ENCROACH INTO THE
TURNING SPACE BY 12 INCHES MAXIMUM. §11B-603.2.3
2
1/2" = 1'-0"ENLARGED ACCESSIBLE COUNTER 11 12" = 1'-0"SERVICE COUNTER ACCESSIBILITY 123
20' - 0"
(E) STOREFRONT
FACADE
(E) STOREFRONT
FRONT DOOR
00
15
'
-
1
0
1
/
2
"
20' - 0"
3' - 8 3/4"
9
MERCHANDISER
REFRIGERATOR
MECHANICAL
DUCTING -SEE
MECH. PLANS
AIR
REGISTER
1
21
BRICK VENEER
11
'
-
1
1
3
/
4
"
14.04°
(E) ROOF SLOPE
17
'
-
1
0
1
/
4
"
A-401
3
9'
-
5
1
/
4
"
WHITE GLOSS PAINT
SEE FINISH SCHEDULE
.19' - 11 1/4"
11
'
-
1
1
3
/
4
"
14.04°
8'
-
8
7
/
8
"
(E) ROOF SLOPE
5/8" GYPSUM WITH
WHITE GLOSS PAINT
SEE FINISH SCHEDULE
9
WALL MOUNTED SOAP DISPENSER
1
WALL MOUNTED PAPER TOWEL DISPENSER2
WALL MOUNTED MIRROR3
WALL MOUNTED HAND WASHING SINK4
6'-0" HEIGHT WALL TILE
5
FLOOR MOUNTED ACCESSIBLE WATER CLOSET6
ACCESSIBLE GRAB BAR7
BOBRICK B-35745 TOILET PAPER AND SEAT COVER DISPENSER8
6" SLIMFIT COVE9
COVED TILE, SEE ARCH DETAILS10
FRP WALL COVERING, SEE FINISH SCHEDULE11
TOILET PAPER HOLDER12
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATEOF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
1
6
/
2
0
2
6
2
:
1
9
:
1
1
P
M
A-401
INTERIOR ELEVATIONS
2510
Au
t
h
o
r
1/2" = 1'-0"2 OPEN DINING - NORTH ELEVATION
1/2" = 1'-0"4 OPEN DINING - SOUTH ELEVATION
1/2" = 1'-0"1 OPEN DINING - WEST ELEVATION
1/2" = 1'-0"3 OPEN DINING - EAST ELEVATION
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 04/06/2026
INTERIOR ELEVATION KEYNOTES
D D
AIR REGISTER PER
MECHANICAL, TYP.
10
'
-
8
"
9
10
'
-
8
"
9
STAINLESS
STEEL DRY
FOOD STORAGE
2
WALK-IN
REFRIGERATOR
2 DOOR FULL
HEIGHT
REFRIGERATOR
DISHWASHER 3 COMP SINKICE MACHINE 1 DOOR
BEVERAGE
REFRIGERATOR
2 DOOR U/C
REFRIGERATOR M48
DDD
D D
4"
6" STAND
1
1
5"
4" CASTER
5"6"
120"
22"22"22"
3'
-
2
"
4"
6"
4" CASTER
4" CASTER
5"
4' - 0 7/8"
3/8" COVE BASE ALL
AROUND. SEE
DETAIL /2 A-5001
24"24"
5' - 0"
2' - 0"
EXTENDABLE FAUCET FOR
ALL 3 COMPARTMENTS. SEE
PLUMBING CUTSHEETS
STAINLESS STEEL FLASHING
UP TO CEILING HEIGHT
8'
-
0
"
1'
-
0
"
6 1/4"
STAINLESS
STEEL DRY
FOOD STORAGE
STAFF
LOCKERS (2)
MOP
SINK
WALL MOUNTED
CLEANING
DISPENSER
A
6"
5
AIR CURTAIN
6'
-
0
"
WALL MOUNTED
SS SHELVING
48
"
M
A
X
.
FOOD
PREP SINK
HAND WASH
SINK
PASTA/NOODLE
COOKER
STOCK
POT
OVENSS SHELVING(E) ELEC
PANEL TO
REMAIN
DEEP
FRYER
STOCK
POT
WATER
TREATMENT
SYSTEM
12"6"
10 1/2"
18"
16' - 0"
ALL EQUIPMENT UNDER HOOD TO BE EQUIPPED WITH MIN. 4" CASTERS -OR TO BE
ELEVATED MIN. 6" ABOVE THE FINISHED FLOOR ON LEGS.
NOTE
VENTED TYPE 1
HOOD - SEE
MECHANICAL
31
"
6"
6"6"4' - 7 1/2"
3'
-
4
1
/
2
"
24"
6"
1
USE REQUIRED ATTACHMENT
SIDE SPLASH, LEFT AND RIGHT
SIDES 1
STAINLESS STEEL WALL
MOUNTED SHELF
6" SIDE SPLASH
GUARD, ONE SIDE
6"
60"
6'
-
0
"
WALL MOUNTED SOAP DISPENSER
1
WALL MOUNTED PAPER TOWEL DISPENSER2
WALL MOUNTED MIRROR3
WALL MOUNTED HAND WASHING SINK4
6'-0" HEIGHT WALL TILE
5
FLOOR MOUNTED ACCESSIBLE WATER CLOSET6
ACCESSIBLE GRAB BAR7
BOBRICK B-35745 TOILET PAPER AND SEAT COVER DISPENSER8
6" SLIMFIT COVE9
COVED TILE, SEE ARCH DETAILS10
FRP WALL COVERING, SEE FINISH SCHEDULE11
TOILET PAPER HOLDER12
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATEOF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
1
6
/
2
0
2
6
2
:
1
9
:
1
3
P
M
A-402
INTERIOR ELEVATIONS
2510
Au
t
h
o
r
1/2" = 1'-0"6 RR HALLWAY - EAST ELEVATION
1/2" = 1'-0"7 RR HALLWAY - SOUTH ELEVATION
1/2" = 1'-0"9 KITCHEN - NORTH ELEVATION
1/2" = 1'-0"10 KITCHEN - EAST ELEVATION
1/2" = 1'-0"11 KITCHEN - SOUTH ELEVATION
1/2" = 1'-0"12 KITCH/STORAGE - WEST ELEVATION
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
1 PLAN RESUBMITTAL 01/16/2026
B HEALTH SUB 2 02/04/2026
C HEALTH SUB 3 02/25/2026
2 PLAN RESUBMITTAL 04/06/2026
INTERIOR ELEVATION KEYNOTES
FINISH FLOOR PER
FINISH PLAN
SCHLUTER FLOOR
TRANSITION STRIP
(ALUMINUM)
SUBFLOORING
GROUT FILLED
D D D
H H H
ALUMINUM & MC 80 D BRASS STAINLESS STEEL
H = THICKNESS OF FINISH MATERIAL
D = 1/4"
(E) WALL STUDS AT 16"
O.C. (DEMISING WALL)
2-SCREWS 2" LONG
AT EA. STUD
16 GA. GALV. SUPPORT (2)
STEEL FORMER 3" X 24"
METAL SCREWS @ 3" O.C.
MUST BE LIQUID TIGHT TO
PREVENT GREASE FIRE.
FOLLOW MANUFACTURER
INSTALLATION INSTRUCTIONS
20 GA. HOOD S.S.
METAL FLASHING
WALL METAL FLASHING
OPTION (A) OPTION (B)
TACK WELD
EXHAUST HOOD
3/8" X 3" LAG SCREW
TO METAL STUD
4"X4"X1" L BRACKET
@48" O.C.
ANGLE IRON 1" X 2"
3" MIN. AIR SPACE
3' - 6"
24
"
M
I
N
.
80
"
M
I
N
.
KITCHEN
EQUIPMENT
PER PLAN
EXHAUST RISER
PER
HOOD ANCHOR,
SEE DETAIL
DRAIN FULL
PERIMETER GUTTER
NOTE: THE OWNER IS
RESPONSIBLE FOR
MAINTAINING HOOD
CLEARANCES FROM
COMBUSTIBLE
MATERIALS
6" MIN. OVERHANG
4'
-
0
"
M
A
X
.
3" MIN. CLEARANCE
BEHIND ALL HEAT-
GENERATING
EQUIPMENT .
/8 A-500
/3 A-500
SEE MECHANICAL FOR
HOOD SPECIFICATIONS6 TIER LOCKER STAINLESS
STEEL PREFAB LOCKER
SIMPSON STRONG TIE
FWANZ Z-MAX SEISMIC
ANCHOR
12"X12"X12" INTERIOR
COMPARTMENT
SPACE
6 IN. MIN. LEG HEIGHT.
USE ROUND LEG FOR
EASE OF CLEANING
NOTE
ACCESSIBLE LOCKER
CUBBIES BETWEEN 15"
MIN. AND 48" MAX. HEIGHT
FLOOR FINISH -SEE
FINISH PLANS
OPENING
EXISTING RAFTER
NEW SISTER JOIST AT OPENING
SIMPSON "L50"
ANGLE, TYP.
HEADER WIDTH
GYP. BOARD ON WOOD STUD
WALL -SEE FLOOR PLAN PER
LOCATION
INTEGRAL COVE BASE QUARRY
OR CERAMIC TILE COVED INTO
FLOOR
GLAZED FLOOR TILE/QUARRY
TILE PER LOCATION
MANUFACTURER SUPPLIED
COVE STICK OR ANGLED
WOOD PIECE FOR SUPPORT
3/8" RADIUS CONTINUOUS
FLOOR TILE MUST COMPLY WITH ACCESSIBLE ROUTE
ACCOMMODATIONS AND NON SLIP SURFACE.
4"
M
I
N
.
PAINT FINISH TO BE GLOSS OR
SEMI-GLOSS PER HEALTH AND
SAFETY CODE
NOTE
METAL STUD
2X DOUBLE
JOIST AT
OPENING
5/8" FIRE RATED
SHEET ROCK ALL
AROUND EACH
SIDE OF OPENING
FIRE RATED
DUCT WRAP,
SEE MECH.
16 GA. GALV.
DUCT WELDED
HOOD FIRE SUPPRESSION SYSTEM TO
BE INSTALLED BY A LICENSED C-16
CONTRACTOR. TESTING AND
INSTALLATION TO MEET LOCAL FIRE
CODE AND REGULATIONS
HOOD DIMENSIONS PER
MECHANICAL DETAILS AND
CEILING PLANS
NOTE
DIAGRAM ONLY - SEE FLOOR
PLANS FOR EQUIPMENT
SELECTIONS AND PROFILE
EXISTING ROOF JOIST
1/2" -13 BOLT
(1/2" STEEL ROD)
HOOD
B3060 SIDE BEAM
ANGLE CLIP
FLAT WASHER
HEX NUT
ALL THREADED ROD
1/2" HANGER ROD
HANGING ANCHOR
EXISTING ROOF
MUST BE ABOVE THE
NEUTRAL AXIS OF WOOD
BEAM AND MINIMUM OF 2" (4
X 1/2" ROD) FROM BOTTOM
OF BEAM
B200 SERIES
SQUARE WASHER
NOTE: ROD AND NUTS TO
BE SUPPLIED BY
INSTALLING CONTRACTOR
HANGING ANGLE IS PRE-
PUNCHED AT FACTORY
ND-2 HANGING
ANGLE
FREE JOINT
ATTACHED JOINT
CROSS RUNNERS, TYP.
LATERAL FORCE BRACING
ASSEMBLY LOCATION, TYP.
CONT ANGLE
@ PERIMETER
NOTE:
1. BRACING WIRES AND COMPRESSION STRUT SHALL OCCUR
AT EVERY 96 SQ. FT. MAX. IN ROOMS OVER 144 SQ. FT.
MAIN RUNNERS
96 SQ
FT
MAX
MAX
4' - 0"
MAX
8' - 0"
MAX
4' - 0"
ATTACHED
JOINT
MA
X
6'
-
0
"
MA
X
12
'
-
0
"
MA
X
6'
-
0
"
FREE
JOINT
FREE
JOINT
ATTACHED
JOINT
19
A-500
18
A-500 TYP.
19
A-500
19
A-500
19
A-500
NOTES:
1. PROVIDE #12 GAGE HANGER WIRES AT THE ENDS OF ALL MAIN AND CROSS
RUNNERS WITHIN EIGHT (8) INCHES OF THE SUPPORT OR WITHIN ONE-
FOURTH (1/4) OF THE LENGTH OF THE END TEE, WHICHEVER IS LESS, FOR
THE PERIMETER OF THE CEILING AREA. PERIMETER WIRES ARE NOT
REQUIRED WHEN THE LENGTH OF THE END TEE IS EIGHT (8) INCHES OR
LESS.
2. FASTEN ANGLE TO WALL STUD OR BLOCKING AS FOLLOWS:
3. (1) # 7 SHEET METAL GUIDING SCREW IS INSTALLED INTO THE SLOT TO
ALLOW THE TERMINAL RUNNER END TO MOVE 3/4" INCH TOWARD AND
AWAY FROM THE WALL. SCREW SHALL NOT BE COMPLETELY TIGHT AS TO
ALLOW SLIDING OF RUNNER.
A. METAL STUD (20 GA. MIN.) WALL: (1) #10 SMS AT 24" O.C. MAX.
B. WOOD STUD WALL: #10x2" LONG WOOD SCREW AT 16" O.C. MAX.
FREE JOINT ATTACHED JOINT
ACM7
M7 ANGLE FOR
DX AND DXT
SEE NOTE #2
BELOW
(1) # 7 GUIDING SCREW
SEE NOTE #3 BELOW
(2) #8 SMS
BETWEEN
ACM7 AND
M7
MAIN OR CROSS
RUNNER
CEILING PANEL
M7 ANGLE FOR
DX AND DXT
#7-7/8" SMS, 1
SCREW THRU
EITHER HOLE
HANGER WIRE, TYP.
ICC-ESR-1222
(2) #8 SMS BETWEEN
ACM7 AND M7
SEE NOTE #2 BELOW
(SEE NOTE 1 BELOW)
8" MAX.
ISO VIEW
(SEE NOTE 1 BELOW)
8" MAX.
3/4" MIN.
CLR.
ACM7
NOTES:
1. STRUTS SHALL NOT REPLACE HANGER WIRES.
2. THE MINIMUM ACCEPTABLE ANGLE IS DETERMINED SUCH THAT THE WIRES DO
NOT INTERFERE WITH THE RUNNERS, LIGHT FIXTURES, ETC. AND REMAIN
STRAIGHT AND UNOBSTRUCTED.
RIGID VERT. STRUT
12 GA VERTICAL HANGERS AT
4'-0" O.C. EACH WAY AT MAIN RUNNER
WITH MINIMUM 3-TIGHT TURNS IN 3" 12 GA. BRACING WIRE W/MIN.
4-TIGHT TURNS IN 1 1/2" BOTH
ENDS OF WIRE CONNECTED TO
MAIN RUNNERS 90º APART, 4-
TOTAL AT EACH STRUT (U.N.O.)
SEE DETAIL
SEE DETAIL
FOR LOCATION OF BRACING
WIRES AND STRUT
MAIN RUNNER
CROSS RUNNER
.
6 MIN
1
0° TO 45° (NOTE 2)
2'-0" TYP
4'-0"
2'-0" TYP
14
A-500
3 TURNS IN 3" AT EACH END, TYP.
SEE DETAIL
HANGER WIRE ONLY
HANGER WIRE
4 TURNS IN 1-1/2" AT EACH END, TYP.
SEE DETAIL
HANGER OR BRACE WIRE
BRACE OR HANGER WIRE
NOTES:
1. WIRE SPLICES ARE SHOWN LOOSELY TIED FOR ILLUSTRATIVE PURPOSES ONLY AND SHALL BE
DRAWN TIGHT TO COMPLETE INSTALLATION WHEN CONSTRUCTED.
2. WIRE LOOPS SHALL BE TIGHTLY WRAPPED AND SHARPLY BENT TO PREVENT ANY VERTICAL
MOVEMENT OR ROTATION WITHIN THE LOOPS.
3. EACH HANGER AND BRACE WIRE SHALL BE SPLICED NO MORE THAN ONCE ALONG ITS LENGTH.
8" MAX.
8" MAX.
1"x 2" x 25 GA. MIN.
CONT. ANGLE THUS:
FASTEN TO WALL
PER NOTE 2 BELOW
HANGER WIRE
@ 4'-0" O.C.
STEEL POP RIVET
AT EACH RUNNER
ATTACHED JOINT FREE JOINT
MAIN RUNNER
CROSS RUNNER
4'-0" MAX FROM FREE JOINT
STRUT AND (4) BRACE WIRES PER
DETAIL WITH SPACING PER
DETAIL
HANGER AT 4'-0" O.C.
EACH WAY AT MAIN
RUNNER
12'-0" MAX
FROM ATTACHED JOINT
8'-0" MAX
NOTES:
1. PROVIDE #12 GAGE HANGER WIRES AT THE ENDS OF ALL MAIN AND CROSS RUNNERS WITHIN EIGHT
(8) INCHES OF THE SUPPORT OR WITHIN ONE-FOURTH (1/4) OF THE LENGTH OF THE END TEE,
WHICHEVER IS LESS, FOR THE PERIMETER OF THE CEILING AREA. PERIMETER WIRES ARE NOT
REQUIRED WHEN THE LENGTH OF THE END TEE IS EIGHT (8) INCHES OR LESS.
2. FASTEN ANGLE TO WALL FRAMING AS FOLLOWS:
A. METAL STUD (20 GA. MIN.) WALL: (1) #10 SMS AT 24" O.C. MAX.
B. WOOD STUD WALL: #10x2" LONG WOOD SCREW AT 16" O.C. MAX.
1"
2"1"x 2" x 25 GA. MIN. CONT.
ANGLE FASTEN TO WALL
PER NOTE 2 BELOW
HANGER WIRE
@ 4'-0" O.C.
18
A-500 11
A-500
STEEL POP RIVET
@ 4'-0" O.C. MAX.
1"x 2" x 25 GA. MIN.
CONT. ANGLE THUS:
FASTEN TO WALL
PER NOTE 2 BELOW
CLR.
3/4"
MIN.
TYP.
0° TO 45°
(SEE NOTE 1 BELOW)
8'-0" MAX. TYP.
1/
2
"
M
I
N
.
T
Y
P
.
TYPICAL SPLICE AT
CROSS RUNNERS
TYP. HANGER
WIRES @ 4'-0"
O.C.
RUNNER SPLICE
MAIN
RUNNER
CROSS
RUNNER
NOTES:
1. DETAIL APPLIES TO EXPANSION JOINTS AT THE INTERSECTION OF CORRIDORS AND AT THE
JUNCTIONS OF CORRIDORS AT LOBBIES AND OTHER SIMILAR AREAS.
2. PROVIDE #12 GAGE HANGER WIRES AT THE ENDS OF ALL MAIN AND CROSS RUNNERS WITHIN
EIGHT (8) INCHES OF THE SUPPORT OR WITHIN ONE-FOURTH (1/4) OF THE LENGTH OF THE END
TEE, WHICHEVER IS LESS, FOR THE PERIMETER OF THE CEILING AREA. PERIMETER WIRES ARE
NOT REQUIRED WHEN THE LENGTH OF THE END TEE IS EIGHT (8) INCHES OR LESS.
STEEL POP RIVET
@ 2'-0" O.C. MAX.
STEEL POP RIVET
@ 2'-0" O.C. MAX.
CONT. MAIN RUNNERS
(SPLICE ALL JOINTS)
TYP. HANGER
WIRES @ 4'-0" O.C.
EXPANSION JOINT
COVER PLATE WITH 1"
FLEXIBILITY MINIMUM IN ALL
HORIZONTAL DIRECTIONS
1" CLEAR
(SEE NOTE 2 BELOW)
8" MAX.
(SEE NOTE 2 BELOW)
8" MAX.
FREE JOINT
EXPANSION JOINT
FREE JOINT
ATTACHED JOINT
FREE JOINT
ATTACHED JOINT
ATTACHED JOINT
CONNECTED TO WALL
12'-0" MAX (TYP)
4'-0" MAX
4'-0" MAX
FREE JOINT
(TYP)
4'-0" MAX
(TYP)
8'-0" MAX
STRUT AND BRACING TYP. PER DETAIL NON-EXIT
CORRIDOR
EXIT CORRIDOR
NON-EXIT CORRIDOR
EXIT CORRIDOR
14
A-500
19
A-500
12
A-500
12
A-500
19
A-500
14
A-500
18
A-500
SLIM FOOT COVE BASE
SEALED CONCRETE
FLOOR PER FINISH PLANS
3/8" RADIUS CONTINUOUS
CONCRETE SEALER MUST COMPLY WITH ENVIRONMENTAL HEALTH PRE-
APPROVED LIST. FLOOR TO BE TEXTURED FOR SLIP RESISTANCE.
4"
M
I
N
.
GYP BOARD WITH
APPROVED FINISH
NOTE
TILE PER FINISH PLANS
EQ
EQ
PARTITION PER PLAN
SEISMIC ANCHORAGE CLIP
STAINLESS STEEL SUPPLY
SHELVING. SEE
EQUIPMENT LIST FOR
HEIGHT AND TIERS
4" MIN. CASTERS
FINISHED
FLOOR
STAINLESS STEEL WALL
MOUNTED SHELVING
WALL FINISH PER PLAN.
SMOOTH, HARD,
NONABSORBENT WALL
SURFACE THAT IS NOT
ADVERSELY AFFECTED
BY WATER TO 48" A.F.F.
4X4 WOOD
BLOCKING/BACKING
MIN. 18 GA. FRAMING ANGLE,
SIMPSON STRONG TIE-A34
OR APPROVED EQUAL, ICC-
ES ESR-2532, TOP AND
BOTTOM AND EACH END
STAINLESS STEEL
MACHINE SCREWS
STAINLESS STEEL SHELF
SUPPORT. REFER TO
SPECIFICATIONS
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATEOF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
1
6
/
2
0
2
6
2
:
1
9
:
1
4
P
M
A-500
DETAILS
2510
Au
t
h
o
r
1 1/2" =
1'-0"FLOOR TRANSITION DETAIL - FLUSH 7
3" = 1'-0"HOOD ANCHOR SUPPORT DETAIL 31/2" = 1'-0"HOOD AND KITCHEN SECTION 41" = 1'-0"LOCKER MOUNTING DETAIL 5
1 1/2" =
1'-0"TYP. OPENING DETAILS 6
1 1/2" =
1'-0"COVE BASE DETAIL 2
1 1/2" =
1'-0"FIRE RATED OPENING SECTION 8
3/4" = 1'-0"HOOD FIRE SUPPRESSION DIAGRAM - FOR REFERENCE ONLY 16
3" = 1'-0"HOOD SUPPORT DETAIL 93/4" = 1'-0"TALL CABINET ANCHOR DETAIL 10
NTSCEILING PLAN BRACE ASSEMBLY 20 NTSSUSPENDED CEILING PERIMETER JOINTS 19 NTSSUSPENSION & LATERAL BRACING 18
NTSTYP. CEILING WIRE SPLICES 13NTSSECTION AT HALLWAY 14 NTSEXPANSION JOINT 12 NTSHALLWAY CEILING PLAN DIAGRAM 11
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
C HEALTH SUB 3 02/25/2026
2 PLAN RESUBMITTAL 04/06/2026
1 1/2" =
1'-0"COVE BASE AT SEALED CONCRETE 1
3" = 1'-0"SHELVING BACKING 15
29
"
M
I
N
.
2'
-
1
0
"
M
A
X
.
40
"
M
A
X
.
T
O
B
O
T
T
O
M
O
F
M
I
R
R
O
R
'
S
R
E
F
L
E
C
T
I
V
E
S
U
R
F
A
C
E
19" MAX.
AS REQ. FOR LAV. AND FAUCET DIM. - 17" MIN.
4"
9"
M
I
N
.
8"
27
"
M
I
N
.
SOLID SURFACE SIDE SPLASH AS
REQUIRED
COUNTERTOP & BACKSPLASH &
APRON. SEE RESTROOM ELEVATIONS.
SEE FINISH SCHEDULE FOR FINISH.
1/8" EASED EDGE,TYP.
UNDER-COUNTER LAVATORY
PROVIDE HANDY-SHIELD (OR
APPROVED EQ.) SAFETY COVERS
(WHEELCHAIR/OFFSET TAILPIECE
COVER & VALVE/SUPPLY COVER)
AROUND DRAIN AND HOT WATER
LINES. COLOR: WHITE.
2 x 2 x 1/4" MTL. ANGLE 3'-0"
O.C. ANCHOR TO FULL HT. METAL
STUDS. PROVIDE FIRE RETARDANT
TREATED WOOD BLOCKING
BETWEEN
STUDS. PROVIDE (3) 3/8" DIA. LAG
BOLTS AT EACH ANGLE.
3/4" CONTINUOUS PLYWOOD
BACKING
SHIM TO SLOPE TO REAR
AS REQUIRED
MIN. CLEAR
SPACE
REQUIRED
2'
-
1
0
"
1
1
/
2
"
3"
4"
M
I
N
.
1/
8
"
GA
P
TY
P
.
1
1
/
2
"
1/2"
2'-0"
4"
5"
1'-7"
KNEE / TOE CLEARANCE
2'
-
3
"
M
I
N
.
KN
E
E
C
L
E
A
R
A
N
C
E
COUNTERTOP. SEE FINISH
SCHEDULE FOR FINISH.
ADA-COMPLIANT STAINLESS
STEEL
SINK W/OFFSET DRAIN
CABINET DOOR FALSE FRONT
TO ALIGN WITH ADJACENT
DRAWERS
3/4" x 3" STRETCHER, TYP.
DRAIN & HOT WATER PIPING TO BE
WRAPPED WITH INSULATION AS
REQUIRED
FRAMELESS CONCEALED
HINGE, TYP.
4" BACKSPLASH WITH 1/8"
EASED EDGE
SEE FINISH SCHEDULE
1/4" MELAMINE BACK, TYP.
ADA-COMPLIANT INTERGRAL
TOE-KICK
2' - 0"
2'
-
6
"
BACKING PER
10/A-820, TYP.
SOLID SURFACE SPLASH
AND COUNTERTOP w/
EASE EDGE
LINE OF FINISHED FLOOR
PARTITION TYPE
PER PLAN
0'
-
9
"
M
I
N
.
2'
-
3
"
M
I
N
.
0' - 11" MIN.
0' - 8" MIN.
KNEE SPACE
1" OVERHANG
34
"
M
A
X
.
H
E
I
G
H
T
0'
-
5
1
/
2
"
1' - 9"
POINT OF SALE DEVICE
REGISTER PER PLANS
4" MIN. COVED BASE W/
3/8" RADIUS REQ'D AT
EMPLOYEE AREA
2X6 WOOD STUD
WOOD BLOCKING
DOUBLE PLYWOOD
FINISH COUNTERTOP
PER FINISH PLANS
ACRYLIC SNEEZE
GUARD, SEE PLANS
PER LOCATION
PLASTERED, SMOOTH
CEMENT FINISH
LED STRIP LIGHT
(OPTIONAL)
BASE BOARD W/COVE
1" OVERHANG
A-501
11
FINISH FLOOR
PER PLANS
TO
E
C
L
R
.
4"
FULL WIDTH OF CASEWORK
FRAME IN 4X STUDS WOOD
BLOCKING BETWEEN
STUDS WITH SIMPSON A34
ANCHORS TOP AND
BOTTOM TO EACH STUD
2X WOOD WALL
STUDS AT 16" O.C.
SADDLE TIE HAS DOUBLE LOOP
AT SUPPORT
#12 GAGE HANGER WIRES
(3) TIGHT TURNS WITHIN 3",
AT BRACE WIRE PROVIDE (4)
TIGHT TURNS WITHIN 1 1/2".
WHEN MULTILE SADDLE TIES
ARE REQUIRED THEY SHALL
ALTERNATE BACK AND FORTH
TO PREVENT TWISTING
COLD-FORMED STEEL SHOWN
(WOOD FRAMING SIMILAR)
SADDLE TIE REQUIRED FOR ALL
WIDTHS GREATER THAN 1/4"
4 TURNS AT BRACE
WIRES TYP. AT EACH
END
ESR-3223 2" SCREW TO
RAFTER CONNECTION
SPACED 48" OC
BRACE WIRE
1 1/2" MAX.
10° TO 45°
#12 GAGE WIRE
1/2" TYP
BEND CLIP TO ALIGN
WITH WIRE
3 TURNS AT
HANGER WIRE
TYP. AT EACH END
HANGER WIRE
3"
M
A
X
.
#12 GAGE WIRE
1/
2
"
T
Y
P
ESR-3223 2" SCREW
TO RAFTER
CONNECTION
SPACED 48" OC
2X6 STUD FRAMING
@16" O.C.
(PER PLAN)
4 3/4".
(1) LAYER OF FIRE
RESISTANT TYPE X 5/8"
GWB AT EACH SIDE
A-501
8
A-501
18
TYPE
W2
SS 16 GA. SHEET COVER
FINISHED FLOOR - SEE
FINISH SCHEDULE
FIRE RESISTANT
JOINT SEALANT
WALL TYPE PER PLANS
5/8" TYPE 'X' GWB, TYP.
SS 16 GA. SHEET
COVER
TYPE
W2
ESR-3027 1/4"Ø ANCHOR W/
1-5/8" MIN. EMBED. @24" O.C.
3
MINIMUM EDGE
DISTANCE 2-1/2"
2X6 SOLE PLATE
FINISHED FLOOR - SEE FINISH
PLANS FOR LOCATION
COVE PER DETAIL
FINISH PLANS
ESR-3027 1/4"Ø ANCHOR W/
1-5/8" MIN. EMBED. @24" O.C.
WALL TYPE PER PLANS
BOTTOM SHEET FRP ON WET
SIDE
TYPE
W4
0.90" FRP FINISH AT WALLS WITH
PLUMBING FIXTURES ATTACHED
3
MINIMUM EDGE
DISTANCE 2-1/2"
BATT INSULATION
TYPE
W3
ESR-2236 (2) 6" TRUSS
SCREW 0.155Ø THRU PLATE
INTO RAFTER W/MIN. EMBED
OF 2.82" @ EA STUD 16" O.C.
2X6 BEVELLED TOP PLATE
(E) STRUCTURE ABOVE
OF (E) ROOF
ANGLE
3
.BEVEL TOP OF DRYWALL
TILE PER FINISH PLAN TILE PER FINISH PLAN
4'
-
0
"
M
A
X
.
5/8" GYP. BOARD
FINISH PER FINISH PLAN
2X BLOCKING
CLEAN WORK SURFACE
PER FINISH PLAN
2x4 WOOD STUD @16" O.C.
SIMPSON STRONG-TIE 2 IN.
W X 2.8 IN. L GALVANIZED
STEEL ANGLE A23Z
J-ANCHOR BOLT
#12 SCREW X 2" LG
MIN. @12" O.C.
U-CHANNEL
1/2" TEMPERED GLASS
EQ EQ
SEALANT AT EDGES
2X4 STUD FRAMING
@16" O.C.
(1) LAYER OF 5/8" GWB
AT NON PLUMB
FIXTURE SIDE
A-501
10
0.90" FRP FINISH AT
WALLS WITH PLUMBING
FIXTURES ATTACHED. SEE
PLANS AND ELEVATIONS
FOR LOCATION
TYPE
W4
A-501
20
INTERMEDIATE
STUD
BATT INSULATION
FINISHED CEILING -
REFER TO RCP
BATT INSULATION
WALL TYPE PER PLAN
CONT. ACOUSTIC
SEALANT, BOTH SIDES
(E) STRUCTURE ABOVE
TYPE
W1
HEADER STUD
PROVIDE LAP DOUBLE TOP PLATE
FOR PARTIAL HEIGHT OR
FREESTANDING WALLS, TYP.
ESR-1539 (2) 16D
NAILS (3.5" X 0.162")
END-NAILED THRU
PLATE INTO RAFTER
3
INTERMEDIATE STUD
A-501
17
A-501
7
5/8" GYP. BD.
BOTH SIDES
TYPE
W1
NOTE
FULL HEIGHT OR FREESTANDING. SEE
PLANS AND SECTIONS FOR LOCATION.
FINISHED FLOOR - SEE
FINISH SCHEDULES
COVE BASE PER
FLOOR PLAN
WALL TYPE PER PLANS
5/8" GYP. BD. BOTH SIDES
TYPE
W1
ESR-3027 1/4"Ø ANCHOR W/
1-5/8" MIN. EMBED. @24" O.C.
3
MINIMUM EDGE
DISTANCE 2-1/2"
FINISHED CEILING -
REFER TO RCP
SLOTTED SLIP TRACK FASTEN PER
ASSEMBLY RECOMMENDATION
FLANGED 16 GA STEEL PLATES
CONFORMING TO THE PROFILE
RAFTERS ABOVE
0.90" FRP FINISH AT WALLS
WITH PLUMBING FIXTURES
ATTACHED
(E) STRUCTURE ABOVE
TYPE
W4
ESR-1539 (3) 16D NAILS (3.5" X
0.162") END-NAILED THRU
PLATE INTO RAFTER @ EA
STUD 16" O.C.3
FINISHED CEILING - REFER
TO RCP
BATT INSULATION
(E) STRUCTURE ABOVE
TYPE
W2
ESR-1539 (2) 16D
NAILS (3.5" X 0.162")
END-NAILED THRU
PLATE INTO RAFTER
@ EA STUD 16" O.C.
.
TOP PLATE STUD
3
2X6 STUD
FRAMING 16" O.C.
(1) LAYER OF 5/8"
GWB AT EACH SIDE
A-501
9
A-501
19
TYPE
W3
INTERMEDIATE
STUD
SEE PLANS AND
ELEVATIONS FOR
ALTERNATE FINISHES PER
LOCATION
FINISHED FLOOR - SEE
FINISH SCHEDULE
JOINT SEALANT
2X6 SOLE PLATE
(1) LAYER OF 5/8" GWB
AT EACH SIDE
TYPE
W3
ESR-3027 1/4"Ø ANCHOR W/
1-5/8" MIN. EMBED. @24" O.C.
3
MINIMUM EDGE
DISTANCE 2-1/2"
3" = 1'-0"TYP. INT. PARTITION WALL 12
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATEOF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
1
6
/
2
0
2
6
2
:
1
9
:
1
5
P
M
A-501
DETAILS
2510
Au
t
h
o
r
1" = 1'-0"LAVATORY COUNTER & APRON 11" = 1'-0"LOWER CABINET AT SINK 21 1/2" =
1'-0"COUNTERTOP DETAIL 5
1" = 1'-0"FLOOR ANCHORED COUNTERTOP 6
1 1/2" =
1'-0"TYP. WOOD BACKING 16
NTSTYP. SADDLE TIE DETAIL 4 NTSTYP. HANGER & BRACING WIRE CONN.3
3" = 1'-0"1 HR RATED WALL 13
3" = 1'-0"BASE AT 1 HR RATED WALL 83" = 1'-0"BASE AT PLUMBED WALL 10
3" = 1'-0"HEAD AT FULL HEIGHT 2X6 PARTITION 19
1 1/2" =
1'-0"LOW WALL W SNEEZE GUARD DETAIL 113" = 1'-0"PLUMBED PARTITION WALL 15
3" = 1'-0"HEAD AT INT. PARTITION WALL 17
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
C HEALTH SUB 3 02/25/2026
2 PLAN RESUBMITTAL 04/06/2026
3 PLAN RESUBMITTAL 2 04/16/2026
3" = 1'-0"BASE AT INT. PARTITION WALL 7
3" = 1'-0"HEAD AT PLUMBED WALL 20 3" = 1'-0"HEAD AT 1 HR RATED WALL 18
3" = 1'-0"FULL HEIGHT 2X6 PARTITION 14
3" = 1'-0"BASE AT FULL HEIGHT 2X6 PARTITION 9
2
HM HOLLOW METAL
PT PAINT
WV WOOD VENEER
NA NOT APPLICABLE
NR NOT RATED
CONTRACTOR'S RESPONSIBILITIES:
1. CONTRACTOR IS RESPONSIBLE TO COORDINATE & VERIFY ALL DOOR FRAME THROAT THICKNESS
FOR EACH LOCATION.
2. FIELD MEASURE ALL OPENINGS PRIOR TO FABRICATION.
3. A CERTIFICATE OF COMPLIANCE WILL BE PROVIDED FOR ALL EXTERIOR DOORS & FIRE RATED
DOORS.
HARDWARE:
1. VERIFY THAT ALL DOORS AND DOOR HARDWARE MEET THE REQUIREMENTS OF THE CALIFORNIA
ADMINISTRATIVE CODE (TITLE 24) & ALL OTHER APPLICABLE GOVERNING CODES & STANDARDS.
NOTIFY THE ARCHITECT IMMEDIATELY IN CASE OF DISCREPANCY.
2. ALL HARDWARE TO BE LEVER-TYPE PER STATE OF CALIFORNIA, TITLE 24, AND THE ADA.
3. SPECIAL LOCKING DEVICES SHALL BE OF AN APPROVED TYPE.
4. ALL DOORS SHALL BE EQUIPPED WITH LEVEL HARDWARE.
5. HAND ACTIVATED HARDWARE SHALL BE CENTERED NOT LESS THAN 30" NOR MORE THAN 44"
ABOVE THE FINISHED FLOOR (CBC 1004.4).
6. NON-REMOVABLE EXTERIOR HINGE PINS REQUIRED ON OUT SWINGING DOORS
7. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED THE FOLLOWING PER THE
REQUIREMENTS OF CALIFORNIA ADMINISTRATIVE CODE, TITLE 24, SECTION 2-3304(M)2:
- INTERIOR DOORS - 5 POUNDS
- EXTERIOR DOORS - 5 POUNDS
- FIRE DOORS - 15 POUNDS
EXIT DOORS:
1. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY
SPECIAL KNOWLEDGE OR EFFORT (CBC 1004.3).
2. ALL DOORS IN PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER
HARDWARE, PANIC BARS OR OTHER TYPE NOT REQUIRING A GRASP TO OPEN (A.D.A C-5.2.7).
3. MANUALLY OPERATED EDGE OR SURFACE MOUNTED FLUSH BOLTS AND SURFACE BOLTS ARE
PROHIBITED ON EXIT DOORS (CBC 1004.3).
4. EXIT ACCESS DOORS TO HAVE LEVER HARDWARE THAT RETRACTS BOTH LOCKS WITH A SINGLE
OPERATION. CBC 1008.1.9.5.
5. PROVIDE A DURABLE SIGN OVER ALL EXIT DOORS STATING THAT "THIS DOOR TO REMAIN
UNLOCKED WHENEVER THE BUILDING IS OCCUPIED."
OTHER:
1. THE BOTTOM 10" OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING DOORS SHALL HAVE A
SMOOTH UNINTERRUPTED SURFACE.
2. MAXIMUM UNDERCUT OF ALL DOORS NOT IN A RATED CORRIDOR SHALL NOT EXCEED 1/2" ABOVE
FINISH FLOOR SURFACE.
3. EXTERIOR LEVEL LANDING MAY SLOPE UP TO 1/4" PER FOOT IN ANY DIRECTION FOR SURFACE
DRAINAGE.
4. THE FLOOR OR LANDING ON EACH SIDE OF A DOOR SHALL BE LEVEL AND NO MORE THAN 1/2"
LOWER THAN THE THRESHOLD OF A DOORWAY CHANGE IN LEVEL BETWEEN 1/4" AND 1/2" AND
SHALL BE BEVELED WITH 1:2 MAX. SLOPE (CBC 1004.9 AND 1004.9.1A)
TYPE A
3'
-
0
"
PE
R
S
C
H
E
D
U
L
E
PER SCHEDULE
TYPE A
PER DOOR SCHEDULE
PE
R
D
O
O
R
S
C
H
E
D
U
L
E
1'
-
0
"
10
"
M
I
N
.
TYPE B
10
"
M
I
N
.
PE
R
D
O
O
R
S
C
H
E
D
U
L
E
PER DOOR SCHEDULE
KICKPLATE KICKPLATE
1'
-
0
"
TYPE C
PE
R
D
O
O
R
S
C
H
E
D
U
L
E
PER DOOR SCHEDULE
PE
R
D
O
O
R
S
C
H
E
D
U
L
E
INTERIOR FINISH (TYP.)
CONT. CAULK BOTH SIDES
HOLLOW METAL JAMB
(1053 THICK) TYP
NEW DOOR. SEE DOOR SCHEDULE
EXISTING 2x WOOD STUDS (TYP.)
2"
1/
2
"
EXISTING 2X WOOD STUDS (TYP.)
INTERIOR FINISH (TYP.)
CONT. CAULK BOTH SIDES
AND BASE OF FRAME
PROVIDE (3) 'Z' ANCHORS
AND (1) FLOOR CLIP
(TYP. EA. JAMB)
HOLLOW METAL JAMB
(1053 THICK) TYP
DOOR. SEE DOOR SCHEDULE
SLOPE 2% MAX.
1
2
1/
4
"
'
1
/
4
"
.
(E) SLAB ON GRADE
ELASTOMERIC SEALANT OVER
EXPANSION JOINT FILLER
(E) CONCRETE PAVING
TILE FLOOR FINISH PER FINISH
SCHEDULE
ACCESSIBLE DOOR THRESHOLD
PER DOOR SCHEDULE, SET IN FULL
BED OF SEALANT
DOOR PER OPENING SCHEDULE
HOLLOW METAL DOOR FRAME PER
DOOR SCHEDULE
EXTERIOR INTERIOR
MA
X
.
1/
4
"
WALL ASSEMBLY, SEE
WALL DETAILS
CONT. CAULK BOTH SIDES
HOLLOW METAL JAMB
REMOVABLE GLAZING STRIP
TEMPERED GLASS WINDOW, PER
SCHEDULE UNDERCUT GLASS
1/8" ALL FOUR SIDES DOUBLE
SIDED FOAM TAPE BETWEEN
GLASS AND FRAME
HEADER, V.I.F. IF EXISTING
HEADER ALREADY PLACED.
PROVIDE HEADER IF MISSING
INTERIOR FINISH (TYP.)
CONT. CAULK BOTH SIDES
HOLLOW METAL JAMB
TEMPERED GLASS
WINDOW, PER SCHEDULE
UNDERCUT GLASS 1/8" ALL
FOUR SIDES DOUBLE SIDED
FOAM TAPE BETWEEN
GLASS AND FRAME
REMOVABLE GLAZING STRIP
2"
1/
2
"
LEVERS PUSH/PULL PANIC BAR EXIT DEVICE
NOTE:DOOR HARDWARE IS MOUNTED 34" MIN -44" MAX FROM FINISH FLOOR TO TOP
OF THE DEVICE.
LATCHING & LOCKING DOORS THAT ARE HAND OPERATED AND WHICH ARE IN A PATH
OF TRAVEL ARE OPERABLE WITH A SINGLE EFFORT (LEVER, PUSH/PULL, PANIC BAR OR
OTHER HARDWARE ASSIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE
ABILITY TO GRASP, PINCH, OR TWIST THE OPENING HARDWARE)
MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 LBF, WHEN FIRE DOORS
ARE REQUIRED THE MAX EFFORT TO OPERATE THE DOOR MAY BE INCREASED TO THE
MINIMUM ALLOWABLE BY THE APPROPRIATE AUTHORITY , NOT TO EXCEED 15 LBF.
NOTES:
1. KICK AND ARMOR PLATES TO BE 1/2" FROM
EDGE OF DOOR LEAVES FOR PAIR OF DOORS.
2. ARMOR PLATE AFFIXED TO FIRE RATED DOOR
SHALL BE LABELED.
PE
R
M
F
R
.
CE
N
T
E
R
O
F
P
U
L
L
3'
-
8
"
U
.
O
.
N
.
3'
-
8
"
A
R
M
P
U
L
L
CE
N
T
E
R
O
F
P
U
S
H
P
L
A
T
E
3'
-
8
"
U
.
O
.
N
.
PUSH PLATE
3" CENTER OF
U.O.N.
3" CENTER OF PULLU.O.N.
5" HOSPITAL PULL
EQ
U
A
L
EQ
U
A
L
PE
R
M
F
R
.
PL
A
T
E
1'
-
0
"
K
I
C
K
1" U.O.N..
BY HARDWARE MANUFACTURER5" PUSH-PULL LATCH
ST
E
E
L
A
R
M
O
R
P
L
A
T
E
2'
-
1
0
"
S
T
A
I
N
L
E
S
S
X
CE
N
T
E
R
L
I
N
E
O
F
LE
V
E
R
L
O
C
K
/
L
A
T
C
H
HA
R
D
W
A
R
E
XX
PU
S
H
-
P
U
L
L
L
A
T
C
H
H
D
W
E
3'
-
8
"
C
E
N
T
E
R
L
I
N
E
O
F
OF
D
E
A
D
B
O
L
T
S
T
R
I
K
E
3'
-
1
1
"
C
E
N
T
E
R
L
I
N
E
2'
-10
"
3'
-4
1
/
2
"
3'
-2"
(
R
I
T
E
D
O
O
R
)
CE
N
T
E
R
L
I
N
E
E
X
I
T
DE
V
I
C
E
S
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATEOF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
1
6
/
2
0
2
6
2
:
1
9
:
1
6
P
M
A-600
DOOR AND WINDOW
SCHEDULE
2510
Au
t
h
o
r
DOOR SCHEDULE
DOO
R TYPE ROOM WIDTH HEIGHT FIRE RATING DOOR MATERIAL DOOR FINISH FRAME MATERIAL FRAME FINISH PHASE
1 A RESTROOM 3' - 0" 7' - 0" NR WD WD WD PT New Construction
2 B OPEN DINING 3' - 0" 7' - 0" NR HM HM HM PT New Construction
3 C STORAGE 3' - 6" 0' - 0" NA NA NA WD PT New Construction
4 (E) REAR 3' - 0" 7' - 0" NR HM HM HM HM Existing
5 (E) ENTRY 3' - 6" 7' - 0" NR GL AL AL PT Existing
WINDOW SCHEDULE
NUMBER TYPE WIDTH HEIGHT LEVEL HEADER HEIGHT COUNT NOTES
1 1 3' - 0" 4' - 0" FIRST FLOOR 7' - 0" 1
DOOR FINISH LEGEND
GENERAL NOTES - DOOR
1/2" = 1'-0"
WINDOW TYPES
3" = 1'-0"DOOR HEADER 13" = 1'-0"DOOR JAMB 2 3" = 1'-0"(E) DOOR ENTRY THRESHOLD 3
1. EACH LITE SHALL BEAR THE MANUFACTURER'S LABEL DESIGNATING THE TYPE AND THICKNESS OF
THE GLASS.
2. GLASS SHALL BE FIRMLY SUPPORTED ON ALL FOUR SIDES.
3. FIELD MEASURE ALL OPENINGS PRIOR TO FABRICATIONS.
4. ALL GLAZING WITHIN A 24" ARC OF EITHER EDGE OF A DOOR AND WITHIN 60" OF THE FLOOR SHALL
BE TEMPERED.
5. REFER TO MANUFACTURER'S DIRECTIONS FOR INSTALLATION.
WINDOW GENERAL NOTES
DOOR AND WINDOW SPECIFICATIONS
1. FIELD MEASURE, AS REQUIRED, ALL DOORS PRIOR TO FABRICATION.
2. PROVIDE A SIGN ON OR NEAR THE MAIN EXIT DOOR READING "THIS DOOR TO REMAIN UNLOCKED
WHEN THIS SPACE IS OCCUPIED".
3. LATCHING AN LOCKING DOORS THAT ARE HAND OPERATED SHALL BE OPERABLE WITH A SINGLE
EFFORT WITHOUT REQUIRING THE ABILITY TO GRASP THE HARDWARE. (LEVER OR PUSH TYPE)
VERIFY THE CONDITION OF EXISTING DOORS.
4. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 LB FOR INTERIOR AND EXTERIOR
DOORS AND 15 LB FOR FIRE DOORS.
5. ALL HARDWARE TO BE LEVER TYPE PER ADA AND GOVERNING CODES.
6. OPENING HARDWARE TO BE CENTERED BETWEEN 34" AND 40" A.F.F. CONTRACTOR TO VERIFY
EXISTING CONDITION AND MATCH NEW.
7. SPECIAL LOCKING DEVICES SHALL BE OF AN APPROVED TYPE.
8. PROVIDE WEATHER SEALS ON ALL EXTERIOR DOORS.
9. CONTRACTOR IS RESPONSIBLE TO VERIFY AND COORDINATE ALL DOOR FRAME THROAT
THICKNESS.
10. ALL DOOR FRAMES TO BE FACTORY FINISHED-UNO
11. ALL DOOR STOPS TO HAVE 2X6 OR 20 GA. BACKING.
12. MAXIMUM UNDERCUT OF ALL DOORS NOT IN A RATED CORRIDOR SHALL NOT EXCEED 1/2" A.F.F.
13. SEE DETAIL FOR DOOR CLEARANCE REQUIREMENTS.
14. ALL DOORS ARE TO BE 3'-0" WIDE UNLESS NOTED OTHERWISE ON PLANS.
15. ALL DESIGNATED EXIT DOORS SHALL BE NON-LOCKING AGAINST EGRESS.
16. ALL THUMB LATCH LOCKING DEVICES ON MEANS OF EGRESS DOORS SHALL BE ACTIVATED BY NO
MORE THAN ONE QUARTER (1/4) TURN.
17. ALL GLASS IN DOORS SHALL BE TEMPERED.
18. ALL DOORS & HARDWARE SHALL COMPLY WITH LOCAL BARRIER FREE LAWS AND THE AMERICANS
WITH DISABILITIES ACT.
19. ALL WOOD DOORS TO BE PARTICLEBOARD CORE DOORS; PERFORMANCE GRADE: EXTRA HEAVY
DUTY; AESTHETIC GRADE: PREMIUM.
20. ALL DOORS TO BE UNDERCUT MIN. 3/4" OR REQ'D BY CODE U.N.O.
21. ALL DOOR FRAMES SHALL BE ONE PIECE WELDED 16 GA. H.M. - PAINT P-5.
22. HOLLOW METAL DOORS SHALL BE 18 GA. FACE SHEETS EXTERIOR DOORS TO BE GALVANIZED &
INSULATED.
23. ALL DOORS, FRAMES & HARDWARE TO BE PROVIDED AND INSTALLED BY GC.
24. ALL DOORS TO BE EQUIPPED W/ MIN. (3) DOOR SILENCERS ON LATCH-SIDE OF DOOR FRAME.
25. ALL HARDWARE TO BE BRUSHED OR SATIN-FINISH STAINLESS STEEL U.N.O.
26. EXTERIOR SIDE OF ALL PERIMETER WALL DOORS & FRAMES TO BE PAINTED AS APPROVED BY
LANDLORD. COORDINATE COLOR W/ EXISTING EXTERIOR DOORS & FRAMES.
1/2" = 1'-0"
DOOR TYPES
3" = 1'-0"WINDOW SILL 53" = 1'-0"WINDOW HEADER JAMB 4
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 04/06/2026
1.A FOOD FACILITY SHALL ALWAYS BE CONSTRUCTED, EQUIPPED, MAINTAINED, AND OPERATED TO PREVENT THE
ENTRANCE AND HARBORAGE OF ANIMALS, BIRDS, AND VERMIN, INCLUDING, BUT NOT LIMITED TO, RODENTS AND
INSECTS.
2. DELIVERY DOORS SHALL BE EQUIPPED WITH AN AIR CURTAIN DEVICE.FOR MORE INFORMATION, REFER TO THE
AIR CURTAIN SECTION.
3. PASS-THROUGH WINDOWS SHALL COMPLY WITH SECTION 114259.2 OF THE CALIFORNIA RETAIL FOOD CODE.
REFER TO THE PASS-THROUGH WINDOW SECTION OF THIS GUIDE FOR FURTHER INFORMATION.
4. INSECT CONTROL DEVICES, DESIGN, AND INSTALLATION: INSECT CONTROL DEVICES THAT ARE USED TO
ELECTROCUTE OR STUN FLYING INSECTS SHALL BE DESIGNED TO RETAIN THE INSECT WITHIN THE DEVICE.
5. INSECT CONTROL DEVICES SHALL BE INSTALLED SO THAT THE DEVICES ARE NOT LOCATED OVER A FOOD OR
UTENSIL HANDLING AREA AND DEAD INSECTS AND INSECT FRAGMENTS ARE PREVENTED FROM BEING
IMPELLED ONTO OR FALLING ON NON-PREPACKAGED FOOD, CLEAN EQUIPMENT, UTENSILS, LINEN, AND
UNWRAPPED SINGLE-USE ARTICLES.
6. EXTERIOR DOORS SHALL BE SELF-CLOSING.
7. THERE SHALL BE NO GAPS IN THE EXTERIOR DOORS. GAPS IN THE EXTERIOR DOORS THAT ARE GREATER THAN
1/4" SHALL BE SEALED USING DURABLE AND RODENT-PROOF WEATHER-STRIPPING MATERIAL.
8. DOORS, SUCH AS ELIASON DOORS, THAT SEPARATE ANY FOOD PREPARATION OR FOOD STORAGE AREA FROM AN
OPEN-AIR DINING ROOM, OPEN-AIR BAR, OR WAREHOUSE AREA WITH ROLL-UP DOORS SHALL BE
SELF-CLOSING AND FULLY VERMIN-PROOF.
9. ALL GAPS, CRACKS, CREVICES, PLUMBING, OR CONDUIT INTRUSIONS SHALL BE SEALED USING APPROVED
MATERIAL TO PREVENT THE ENTRANCE AND HARBORAGE OF VERMIN.
10.THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS:
§11B-404.2.9
A. INTERIOR HINGED DOORS AND GATES: 5 POUNDS MAXIMUM.
B. SLIDING OR FOLDING DOORS: 5 POUNDS MAXIMUM.
C. REQUIRED FIRE DOORS: THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE
ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 POUNDS.
D. EXTERIOR HINGED DOORS: 5 POUNDS MAXIMUM.
1/2" = 1'-0"HARDWARE DIAGRAM 72
2
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATEOF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
1
6
/
2
0
2
6
2
:
1
9
:
1
9
P
M
A-700
EQUIPMENT CUTSHEETS
2510
Au
t
h
o
r
GAS RANGE STOCK POT STOVE
FULL HEIGHT 1 DOOR REFRIGERATOR
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
1 PLAN RESUBMITTAL 01/16/2026
B HEALTH SUB 2 02/04/2026
C HEALTH SUB 3 02/25/2026
2 PLAN RESUBMITTAL 04/06/2026
ARMSTRONG CLEAN ROOM VL -CEILING TILE
1
1
MEGA TOP WORKTOP REFRIGERATOR
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATEOF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
4/
1
6
/
2
0
2
6
2
:
1
9
:
2
2
P
M
A-701
EQUIPMENT CUTSHEETS
2510
Au
t
h
o
r
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
C HEALTH SUB 3 02/25/2026
2 PLAN RESUBMITTAL 04/06/2026
WALL MOUNTED SHELF CHEMICAL DISPENSER
STAFF LOCKERSERVICE WINDOW
PREP TABLE
YES NO
INSTRUCTIONS:
ORAN GE COUNTY FI RE AUTHORI TY
Plan Submittal Criteria
COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects
and RESIDENTIAL TRACT developments
· Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place.
· Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section.
· If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA.
· In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations.
· Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding
requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602.
Address Suite City
Project Scope/Business Description
1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways,
curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within
300 feet of an active or proposed oil well? Fire Master Plan (PR145)
2. Property is adjacent to a wildland area or non-irrigated native vegetation?
Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124)
3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from
an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170)
4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving
private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475)
5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000
sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable
to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless
classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration
or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses
where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories
with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285)
6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card,
button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan
depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520)
7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment;
industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible
liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium
ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations?
Special Equipment Plan (PR315, PR340-PR382)
8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft
maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if
H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240)
9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard
commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330)
10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a
commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335)
Initial each of the following two items indicating that you have read and understand the statement:
11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is
required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed
Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications.
12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located
in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327—
Initials the building department will determine specific requirements.
I certify under penalty of perjury under the laws of the State of California that the above is true:
Print Name Signature
Phone Number ( ) Date / /
Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA
review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the
applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the
appropriate plans and fees for OCFA review. 10-08-14 EE
COM
O R A N G E C O U N T Y F I R E A U T H O R I T Y
Plan Referral Form
Required for OCFA to review plans upon the request of the Building Department when
the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”.
City / County Official Requesting Review:
City / County Reference #: Date: __________________________________
City / County: _____________________________________ E-Mail: __________________________________
Contact Name: _____________________________________ Phone #: _________________________________
Title: _____________________________________
** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. **
Reason(s) for Review:
Please describe why OCFA Plan Review is or may be required by the City/County :
OCFA COMMENTS:
No further action required on this specific plan type, based
on information provided on: ____/______/______.
Project to be taken in for OCFA Review.
Other:
Name: _________________________________________
Contact #: ______________________________________ Date: _________________________________
OCFA Authorization
Updated: 06/02/2020 rs
GREASE INTERCEPTOR MEMORANDUM
To: Sukitti Keeratiprapa - Applicant Date: 1/15/2026
Luis A Dimas – Engineering Aide
From: PWA, Water Resources
Location: 128 W MACARTHUR BLVD – THE NOODLE LOFT
The above referenced food service establishment (FSE) must comply with the Fats, Oils, and Grease
(FOG) Control Program Rules and Regulations as identified in Ordinance NS-2921 and as follows:
A Gravity Grease Interceptor (GGI) is required at this FSE
☐ This FSE shall install a Gravity Grease Interceptor (GGI).
☒ This FSE shall maintain the existing Gravity Grease Interceptor (GGI).
This FSE qualifies for at least one of the following condition(s):
This is a new FSE, or;
This is an existing FSE undergoing remodeling, or;
This is an existing FSE involving a change (of operation, ownership, and/or name) that is likely to
continue discharging a high level of FOG or has the potential to increase the amount of FOG discharged
to the sewer system.
C/c: Water Resources Division
Planning & Building Agency
OC Health Care Agency
Public Works Agency (Development)
EEC Environmental
Applicant
SHEET INDEX
THE NOODLE LOFT
128 W MACARTHUR BLVD
SANTA ANA, CA 92707
• DEMOLITION OF THE EXISTING NON-BEARING WALLS OF THE PREVIOUS TENANT SPACE.
• NEW ELECTRICAL WIRING FOR COMMERCIAL KITCHEN AND OPEN DINING SPACES. INSTALLATION
WORK TO BE COMPLETED BY A LICENSED ELECTRICIAN. NEW ROUTING AND DUCTING TO BE
CONNECTED TO THE EXISTING MECHANICAL UNIT. NEW PLUMBING FIXTURES AND
UNDERGROUND PIPING TO BE INSTALLED.
• UPGRADE TO RESTROOM TO MEET ACCESSIBILITY CODE COMPLIANCE.
• INSTALLATION OF NEW VENTED HOOD AND MAKE-UP AIR SYSTEM.
A. P. N.:
ADDRESS:
ZONING:
TYPE OF CONSTRUCTION:
OCCUPANCY:
BUILDING AREA S.F.
PROPOSED S.F.:
SPRINKLERED:
SCOPE OF WORK
PROJECT INFORMATION
K1
K1
ROOM
NAME
101
A2.32
1
1
1
1 ELEVATION
ALIGN
DIMENSION CENTERLINE
DIMENSION
REVISION CLOUD
KEY NOTE
COLUMN GRID LINE
ROOM REFERENCE
SECTION
REFERENCE
ELEVATION
REFERENCE
DETAIL OR ENLARGED PLAN
DATUM
7' - 6"
7' - 6"
CL
SHEET NUMBER
VIEW NUMBER
VIEW NAME
DRAWING SCALE
VIEW NUMBER
NORTH ARROW
(PROJECT NORTH U.O.N.)
101
LEGEND AND SYMBOLS
VICINITY MAP
APPLICABLE CODE
DEFERRED SUBMITTAL
3' - 9"3' - 9"
AUTHORITY HAVING JURISDICTION : CITY OF SANTA ANA
ALL WORK SHALL COMPLY WITH THE FOLLOWING CODES:
• 2022 CALIFORNIA BUILDING CODE
• ORANGE COUNTY ENVIRONMENTAL HEALTH DEPARTMENT
• 2022 CALIFORNIA ELECTRICAL CODE
• 2022 CALIFORNIA PLUMBING CODE
• 2022 CALIFORNIA MECHANICAL CODE
• 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE
• 2022 CALIFORNIA ENERGY CODE
• 2022 CALIFORNIA FIRE CODE
SITE FACILITY MAP
PROJECT TEAM
KEY NOTE
A-?
?
DETAIL SECTION
REFERENCEA-?
?
A-?
1
410-041-51
128 W MACARTHUR BLVD, SANTA ANA, CA 92707
C4 - COMMERCIAL PLANNED SHOPPING CENTER
TYPE V-B
GROUP B
1,240 SQUARE FOOT
N/A
NO
PROJECT SITE
• ANSUL FIRE SUPPRESSION SYSTEM
OWNER: LEGACY THAI GROUP
CONTACT: SUKITTI KEERATIPRAPA
E-MAIL: LEGACYTHAIGROUP@GMAIL.COM
TEL: (949) 836-1777
ARCHITECT OF RECORD : SANDPIPER ARCHITECTURE
CONTACT: SAMUEL PIPER
E-MAIL: SANDPIPERARCHITECT@GMAIL.COM
TEL: (707) 815-6742
ENGINEER OF RECORD: ERIC CHEN
CONTACT: ERIC CHEN
E-MAIL: HSINGYUERIC@GMAIL.COM
TEL: (626) 423-8463
55
73
405
S
B
R
I
S
T
O
L
S
T
MACARTHUR BLVD
MA
I
N
S
T
BE
A
R
S
T
PROJECT LOCATION
BAKER ST JOHN
WAYNE
AIRPORT
RED HILL AVE
E DYER RD
A.F.F.ABOVE FINISHED FLOOR
A.G.ACCESSORY GROUP
A.D.ACCESS DOOR
ACOUS ACOUSTICAL
ACT.ACOUSTICAL TILE
ADD ADDENDUM
ADJ ADJACENT
A.C.AIR CONDITION
ALT ALTERNATE
ALUM ALUMINUM
A.B.ANCHOR BOLT
APPROX APPROXIMATE
ARCH ARCHITECTURAL
AD AREA DRAIN
AUTO AUTOMATIC
ASL ABOVE SEA LEVEL
B.E.J.BRICK EXPANSION JOINT
BSMT BASEMENT
B.T.BATH TUB
BM BEAM
BRG BEARING
B.M.BENCH MARK
BET BETWEEN
BIT BITUMINOUS
BLK BLOCK
BLKG BLOCKING
BD BOARD
BS BOTH SIDES
BOT BOTTOM
BRK BRICK
B.C.BRICK COURSE
BLDG BUILDING
BUR BUILT-UP ROOFING
B.O.BY OWNER
CAB CABINET
C.H. CABINET HEATER
CHNL CHANNEL
C.O.CLEAN OUT
CO2 CARBON DIOXIDE
CARP.CARPET
C.W.CASEWORK
C.I.CAST IRON
C.B.CATCH BASIN
CEM CEMENT
CM CENTIMETER
CT CERAMIC TILE
CHBD CHALK BOARD
CLG. CEILING
CLR CLEAR
COL COLUMN
CONC.CONCRETE
CMU CONCRETE MASONRY UNIT
COND CONDUCTIVE
C.S.V CONDUCTIVE SHEET VINYL
CONT.CONTINUOUS
CLL CONTRACT LIMIT LINE
CONTR CONTRACTOR
C.J.CONTROL JOINT
CONV CONVECTOR
C.G.CORNER GUARD
CORR CORRIDOR
C.S.COUNTER SINK
CRS COURSE
C.R.CURTAIN ROD
C.R.-1 CRASH RAIL
DEM DEMOLISH/DEMOLITION
DET.DETAIL
DIAG DIAGONAL
DIA. DIAMETER
DIFF. DIFFUSER
DIM. DIMENSION
DISP.DISPENSER
DO DITTO
DR DOOR
DBL DOUBLE
DN DOWN
DS DOWNSPOUT
DWG.DRAWING
D.F.DRINKING FOUNTAIN
EA EACH
ELEC.ELECTRICAL
ELEC. CAB ELECTRIC CABINET
EPNL ELECTRIC PANEL
EWC ELECTRIC WATER COOLER
EL ELEVATION
ELEV. ELEVATOR
EQ EQUAL
E.O.EQUIPMENT BY OWNER
EX EQUIPMENT, X-RAY
EX.F EXHAUST FAN
(E)EXISTING
EXP. JT.EXPANSION JOINT
EXP'D EXPOSED
EXT EXTERIOR
E.I.F.S.EXTERIOR INSULATION
& FINISH SYSTEM
FB FACE BRICK
F.C.U.FAN COIL UNIT
F.D.C.FIRE DEPARTMENT
CONNECTIONS
F.N.V.FEM. NAPKIN VENDOR
FIN.RAD.FIN TUBE RADIATION
FIN FINISH
F.A.FIRE ALARM
FEC FIRE EXTINGUISHER CAB
FHC FIRE HOSE CABINET
F.H.FIRE HYDRANT
F.P.FIRE PROOFING
FHMS FLAT HEAD MACH.SCREW
FHWS FLAT HEAD WOOD SCREW
FL. FLOOR
F.D.FLOOR DRAIN
FR FRAME
F.S. FINISH SLAB
FT FOOT
FTG FOOTING
FDTN FOUNDATION
FUR FURRING
FUR. CH.FURRING CHANNEL/S
F.W.FULL WIDTH
F.W.C.FABRIC WALL COVERING
GAL GALLON
GALV.GALVANIZED
GI GALVANIZED IRON
GA GAGE
G.C.GENERAL CONTRACT
GL GLASS
G.B.GRAB BAR
GSF GROSS SQUARE FEET
G.W.B.GYPSUM WALL BOARD
HR-1 HANDRAIL
HDNR HARDENER
HDW HARDWARE
HD.WD.HARDWOOD
HTR HEATER
HTG HEATING
HVAC HEATING, VENTILATION
& AIR CONDITIONING
HT HEIGHT
HC HOLLOW CORE
HM HOLLOW METAL
HORIZ HORIZONTAL
HB HOSE BIB
H.C.HOSE CABINET
H.C.U.HOSPITAL CASEWORK UNIT
H.C.T.HOSPITAL CUBICAL TRACK
H.PL. HOT PLATE
H.P.L.HIGH PRESSURE
PLASTIC LAMINATE
H.W.HOT WATER
HR HOUR
INCIN.INCINERATOR
I.D.INSIDE DIAMETER
INSUL. INSULATE(D)(ION)
INS. GL INSULATED GLASS
INT INTERIOR
IV INTRAVENOUS
INV INVERT
JAN JANITOR
JT JOINT
KIT KITCHEN
KO KNOCK OUT
L.C.LABORATORY CASEWORK
LEV LOW EMISSION VEHICLE
LAM LAMINATED
LAV.LAVATORY
L.GL.LEADED GLASS
LH LEFT HAND
LGT LENGTH
LT LIGHT
LT.P LIGHT PANEL
LTWT LIGHT WEIGHT
L.F.LINEAR FEET
LTL LINTEL
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LVR LOUVER
L.P.LOW POINT
MACH MACHINE
M.H.MANHOLE
MFR MANUFACTURER
MARB MARBLE
MAS MASONRY
M.O.MASONRY OPENING
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MC MEDICINE CABINET
MEMB MEMBRANE
MET METAL
MTD MOUNTED
M.T.P.METAL TOILET PARTITION
MET. TM METAL TRIM
M.W.U.MILLWORK UNIT
MIN. MINIMUM
MISC.MISCELLANEOUS
MOD MODULAR
M.H.MOP HOPPER
MOV MOVABLE
MULL MULLION
(N)NEW
NAT NATURAL
N.L. NIGHT LIGHT
N2O NITROUS OXIDE
NRC NOISE REDUCTION COEIF.
N.I.C. NOT IN CONTRACT
N.T.S.NOT TO SCALE
NOM NOMINAL
NO. NUMBER
OBS OBSCURE
O.C.ON CENTER
OPNG OPENING
OPP OPPOSITE
OPH OPPOSITE HAND
O.D.OUTSIDE DIAMETER
OHMS OVAL HEAD MACH. SCREW
OHWS OVAL HEAD WOOD SCREW
OA OVERALL
OH OVERHEAD
O2 OXYGEN
PNT PAINT(ED)
PNL PANEL
P.T.D PAPER TOWEL DISPENSER
P.T.R.PAPER TOWEL RECEPTACLE
P.BD.PARTICLE BOARD
PTN PARTITION
PVMT PAVEMENT
PG.BD.PEG BOARD
PLAS.PLASTER
P.LAM PLASTIC LAMINATE
PL PLATE
PL.GL.PLATE GLASS
PLMB PLUMBING
PMLD PREMOLDED
PWD PLYWOOD
PT POINT
PPGL POLISHED PLATE GLASS
PPTGL POLISHED PLATE
TEMPERED GLASS
PPWGL POLISHED PLATE
WIRE GLASS
PVC POLYVINYL CHLORIDE
PCF POUNDS PER CU.FT.
PSI POUNDS PER SQ. INCH
PSF POUNDS PER SQ.FT.
P.P.POWER PANEL
PCP PRECAST CONCRETE PANEL
PRE. FAB. PREFABRICATED
PREF. PREFINISHED
PSC PRE-STRESS CONC.
PROJ PROJECTION
PL PROPERTY LINE
PTDF PRESSURE TREATED
DOUGLAS FIR
QTY QUANTITY
QT QUARRY TILE
RAD RADIUS
R.W.L.RAIN WATER LEADER
RECPT.RECEPTACLE, ELECTRIC
REC.RECESS(ED)
RE:REFER TO
R.C.P.REFLECTED CEILING PLAN
REFR.REFRIGERATOR
REG. REGISTER
REINF. REINFORCE(D)(ING)
REQ'D REQUIRED
RES RESILIENT
R.C.P.REINF. CONC. PIPE
RET RETURN
RA RETURN AIR
RVS REVERSE
REV REVISION
RH RIGHT HAND
ROW RIGHT OF WAY
R RISER
RVT RIVET
R.D.ROOF DRAIN
RFH ROOF HATCH
R.V.ROOF VENT
RFG ROOFING
RM ROOM
R.F.S.ROOM FINISH SCHEDULE
RO ROOF OPENING
RND ROUND
RBL RUBBLE STONE
S.A.M.F.SELF-ADHERED MEMBRANE
FLASHING
SDL SADDLE
S.N.C.SAN. NAP. CABINET
S.N.D.SAN.NAP.DISPOSER
STC SEALANT
STG SEATING
SECT.SECTION
S.S.SERVICE SINK
S.B.SHAMPOO BOWL
SHTH SHEATHING
SHT SHEET
SH SHELF, SHELVING
SHR SHOWER
SIM. SIMILAR
S SINK
S.DI.SOAP DISPENSER
SPKR SPEAKER
S.F.C. SPECIAL FLR. COATING
S.W.C.SPECIAL WALL COATING
S.O.G SLAB ON GRADE
SPEC.SPECIFICATIONS
SQ SQUARE
SST STAINLESS STEEL
SP STAND PIPE
STD STANDARD
STL STEEL
STER STERILIZER
SD STORM DRAIN
S.G.T.STRUCTURAL GLAZED TILE
STRUCT STRUCTURAL
SUSP.SUSPENDED
S.V.SHEET VINYL
SW SWITCH
SWBD SWITCH BOARD
SYM SYMMETRICAL
T.B.TACKBOARD
T.P.TANGENT POINT
TEL TELEPHONE
TEMP TEMPERATURE
TEMP. GL.TEMPERED GLASS
TER.TERRAZZO
TEX.TEXTURE
THK THICK(NESS)
THR THRESHOLD
T.D.TISSUE DISPENSER
T TOILET (FIXTURE)
TPH TOILET PAPER HOLDER
T&G TONGUE & GROOVE
T.O.S.TOP OF STEEL
T.O.B TOP OF BEAM
T.O.C.TOP OF COLUMN
T.O.F.TOP OF FASCIA
T.O.FTG TOP OF FOOTING
T.O.P.TOP OF PARAPET
T.O.W.TOP OF WALL
TB TOWEL BAR
TYP TYPICAL
U.C.UNDERCUT
U/C UNDER COUNTER
U.C.L.UNDER COUNTER LIGHT
U.L.UNDERWRITERS
LABORATORIES INC.
UNGND UNDERGROUND
U.H.UNIT HEATER
U.V.UNIT VENTILATOR
U.O.N.UNLESS OTHERWISE NOTED
UR URINAL
UPH.UPHOLSTERY
V.T.R.VENT THROUGH ROOF
VENT VENTILATOR
V.I.F.VERIFY IN FIELD
VERT VERTICAL
VEST VESTIBULE
V.C.T.VINYL COMPOSITION TILE
V.W.C. VINYL WALL COVERING
V VINYL
VT VINYL TILE
WSCT WAINSCOT
W WASTE
WC WATER CLOSET
W.L.WATER LINE
WS WEATHER STRIP
WT WEIGHT
WWF WELDED WIRE FABRIC
W.C.D.F.WHEELCHAIR DRINKING
FOUNTAIN
WG WIRE GLASS
W.M.P.WIRE MESH PARTITION
W/WITH
W/O WITHOUT
WD WOOD
W.R.B. WATER-RESISTANT BARRIER
(WEATHER-RESISTANT
BARRIER)
ABBREVIATIONS
*NOTE -FIRE SUPPRESSION SYSTEM BUILT INTO HOOD AND COMMERCIAL KITCHEN
WEST MACARTHUR
MA
I
N
S
T
R
E
E
T
55
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATE OF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
US
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
3/
9
/
2
0
2
6
4
:
2
2
:
5
6
P
M
G-001
PROJECT INFORMATION
2510
Au
t
h
o
r
SHEET # SHEET NAME
1 - GENERAL
G-001 PROJECT INFORMATION
G-101 GENERAL NOTES
G-110 CALIFORNIA GREEN BUILDING STANDARD CODE
G-111 CALIFORNIA GREEN BUILDING STANDARD CODE
G-112 CALIFORNIA GREEN BUILDING STANDARD CODE
G-113 CALIFORNIA GREEN BUILDING STANDARD CODE
G-120 CODE ANALYSIS
G-140 ADA SITE AND PARKING DETAILS
G-141 ACCESSIBILITY DETAILS & NOTES
G-142 ACCESSIBILITY DETAILS & NOTES
2 - ARCHITECTURE
A-001 AS-BUILT REFERENCE
A-010 SITE PLAN
A-100 DEMO FLOOR PLAN
A-200 FLOOR PLAN
A-201 FINISH FLOOR PLAN
A-210 RCP AND ROOF PLAN
A-300 SECTIONS
A-310 EXTERIOR ELEVATIONS
A-400 ENLARGED PLANS
A-401 INTERIOR ELEVATIONS
A-402 INTERIOR ELEVATIONS
A-500 DETAILS
A-501 DETAILS
A-600 DOOR AND WINDOW SCHEDULE
A-700 EQUIPMENT CUTSHEETS
A-701 EQUIPMENT CUTSHEETS
3 - MECHANICAL
M-001 MECHANICAL COVER SHEET
M-200 MECHANICAL PLANS
M-500 MECHANICAL DETAILS
M-700 MECHANICAL CUTSHEETS
M-701 MECHANICAL CUTSHEETS
M-702 WALK-IN REFRIGERATOR
M-800 TITLE 24 COMPLIANCE
4 - ELECTRICAL
E-001 ELECTRICAL COVER SHEET
E-200 ELECTRICAL PLANS
E-600 PANEL AND SINGLE LINE DIAGRAM
E-700 ELECTRICAL CUTSHEETS
5 - PLUMBING
P-001 PLUMBING COVER SHEET
P-200 PLUMBING PLANS
P-500 PLUMBING DETAILS
P-700 PLUMBING CUTSHEETS
P-701 PLUMBING CUTSHEETS
P-800 TITLE 24 COMPLIANCE
TOTAL: 43
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 03/09/2026
OCCUPANCY LEGEND
1006.3.3 EGRESS BASED ON OCCUPANT LOAD
EACH STORY AND OCCUPIED ROOF SHALL HAVE THE MINIMUM NUMBER OF SEPARATE AND DISTINCT
EXITS, OR ACCESS TO EXITS, AS SPECIFIED IN TABLE 1006.3.3. A SINGLE EXIT OR ACCESS TO A SINGLE
EXIT SHALL BE PERMITTED IN ACCORDANCE WITH SECTION 1006.3.4. THE REQUIRED NUMBER OF
EXITS, OR EXIT ACCESS STAIRWAYS OR RAMPS PROVIDING ACCESS TO EXITS, FROM ANY STORY OR
OCCUPIED ROOF SHALL BE MAINTAINED UNTIL ARRIVAL AT THE EXIT DISCHARGE OR A PUBLIC WAY.
1017.2 LIMITATIONS
EXIT ACCESS TRAVEL DISTANCE
SHALL NOT EXCEED THE VALUES
GIVEN IN TABLE 1017.2
1010.1.1 SIZE OF DOORS
THE REQUIRED CAPACITY OF EACH
DOOR OPENING SHALL BE SUFFICIENT
FOR THE OCCUPANT LOAD THEREOF
AND SHALL PROVIDE A MINIMUM
CLEAR OPENING WIDTH OF 32 INCHES
(813 MM). THE CLEAR OPENING WIDTH
OF DOORWAYS WITH SWINGING
DOORS SHALL BE MEASURED
BETWEEN THE FACE OF THE DOOR
AND THE STOP, WITH THE DOOR
OPEN 90 DEGREES (1.57 RAD). WHERE
THIS SECTION REQUIRES A MINIMUM
CLEAR OPENING WIDTH OF 32 INCHES
(813 MM) AND A DOOR OPENING
INCLUDES TWO DOOR LEAVES
WITHOUT A MULLION, ONE LEAF
SHALL PROVIDE A MINIMUM CLEAR
OPENING WIDTH OF 32 INCHES (813
MM).
1005.3.2 OTHER EGRESS
COMPONENTS
THE CAPACITY, IN INCHES, OF MEANS
OF EGRESS COMPONENTS OTHER
THAN STAIRWAYS SHALL BE
CALCULATED BY MULTIPLYING THE
OCCUPANT LOAD SERVED BY SUCH
COMPONENT BY A MEANS OF EGRESS
CAPACITY FACTOR OF 0.2 INCH (5.1
MM) PER OCCUPANT.
1005.3.2 OTHER EGRESS COMPONENTS
THE CAPACITY, IN INCHES, OF MEANS OF EGRESS COMPONENTS OTHER THAN STAIRWAYS SHALL BE
CALCULATED BY MULTIPLYING THE OCCUPANT LOAD SERVED BY SUCH COMPONENT BY A MEANS OF
EGRESS CAPACITY FACTOR OF 0.2 INCH (5.1 MM) PER OCCUPANT.
CODE ANALYSISEGRESS BASED ON OCCUPANT LOAD ACCESS TRAVEL
1-500
501 - 1,000
2
3
4
MINUMUN NUMBER OF EXITS OR
ACCESS TO EXITS FROM STORY
MORE THEN 1,000
OCUPANT LOAD
PER STORY
TABLE 1006.3.3
MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY
TABLE 1017.2
EXIT ACCESS TRAVEL DISTANCEª
A,E,F-1,M,S-1
OCCUPANCY WITHOUT SPRINKLER
SYSTEM (FEET)
WITH SPRINKLER
SYSTEM (FEET)
200e 250b
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
200
300
150
200c
200c
200c
R-2.1
B
F-2, S-2, U
H-1
H-2
H-3
H-4
H-5
I-2, I-2.1, I-3f
I-4
L
TOTAL
OCCUPANTS 49250b
300b
400b
75b
100b
150b
175b
200b
B BUSINESS A-2 ASSEMBLY NO OCCUPANTS
- EXIT REQUIRED:
OCCUPANT LOAD: 49 OCC
OCCUPANCY: B - BUSINESS
EXITS REQUIRED (CBC TABLE 1006.3.3): 2
EXIT PROVIDED: 2 (1 EGRESS FROM KITCHEN)
A - HEIGHT OF ACCESSORIES
CBC 11B SECTION 11B-603.5
WHERE TOWEL OR SANITARY NAPKIN DISPENSERS, WASTE RECEPTACLES, OR OTHER ACCESSORIES
ARE PROVIDED IN TOILET FACILITIES, AT LEAST ONE OF EACH TYPE SHALL BE LOCATED ON AN
ACCESSIBLE ROUTE. ALL OPERABLE PARTS, INCLUDING COIN SLOTS, SHALL BE 40 INCHES (1016 MM)
MAXIMUM ABOVE THE FINISH FLOOR.
B - ACCESSIBLE ROUTE TO ACCESSIBLE COMPARTMENT
CBC 11B SECTION 11B-403.5.1 EXCEPTIONS: 5
THE CLEAR WIDTH FOR ACCESSIBLE ROUTES TO ACCESSIBLE TOILET COMPARTMENTS SHALL BE 44
INCHES (1118 MM) EXCEPT FOR DOOR-OPENING WIDTHS AND DOOR SWINGS.
C - STALL WIDTH
CBC 11B SECTION 11B-604.8.1.1
WHEELCHAIR ACCESSIBLE COMPARTMENTS SHALL BE 60 INCHES (1524 MM) WIDE MINIMUM MEASURED
PERPENDICULAR TO THE SIDE WALL, AND 56 INCHES (1422 MM) DEEP MINIMUM FOR WALL HUNG WATER
CLOSETS AND 59 INCHES (1499 MM) DEEP MINIMUM FOR FLOOR MOUNTED WATER CLOSETS MEASURED
PERPENDICULAR TO THE REAR WALL. WHEELCHAIR ACCESSIBLE COMPARTMENTS SHALL ADDITIONALLY
PROVIDE MANEUVERING SPACE COMPLYING WITH SECTION 11B-604.8.1.1.1, 11B-604.8.1.1.2, OR 11B-
604.8.1.1.3, AS APPLICABLE. WHEELCHAIR ACCESSIBLE COMPARTMENTS FOR CHILDREN'S USE SHALL BE
60 INCHES (1524 MM) WIDE MINIMUM MEASURED PERPENDICULAR TO THE SIDE WALL, AND 59 INCHES
(1499 MM) DEEP MINIMUM FOR WALL HUNG AND FLOOR MOUNTED WATER CLOSETS MEASURED
PERPENDICULAR TO THE REAR WALL.
D - ACCESSIBLE STALL DOOR
CBC 11B Section 11B-604.8.1.2
TOILET COMPARTMENT DOORS, INCLUDING DOOR HARDWARE, SHALL COMPLY WITH SECTION 11B-404
EXCEPT THAT IF THE APPROACH IS FROM THE PUSH SIDE OF THE COMPARTMENT DOOR, CLEARANCE
BETWEEN THE DOOR SIDE OF THE COMPARTMENT AND ANY OBSTRUCTION SHALL BE 48 INCHES (1219
MM) MINIMUM MEASURED PERPENDICULAR TO THE COMPARTMENT DOOR IN ITS CLOSED POSITION.
DOORS SHALL BE LOCATED IN THE FRONT PARTITION OR IN THE SIDE WALL OR PARTITION FARTHEST
FROM THE WATER CLOSET. WHERE LOCATED IN THE FRONT PARTITION, THE DOOR OPENING SHALL BE
4 INCHES (102 MM) MAXIMUM FROM THE SIDE WALL OR PARTITION FARTHEST FROM THE WATER
CLOSET. WHERE LOCATED IN THE SIDE WALL OR PARTITION, THE DOOR OPENING HINGE SIDE JAMB FOR
OUT SWINGING DOORS SHALL BE FARTHEST FROM THE WATER CLOSET AND THE STRIKE SIDE JAMB
SHALL BE 54 INCHES (1372 MM) MINIMUM FROM THE REAR WALL. THE DOOR SHALL BE SELF-CLOSING. A
DOOR PULL COMPLYING WITH SECTION 11B-404.2.1 SHALL BE PLACED ON BOTH SIDES OF THE DOOR
NEAR THE LATCH. DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED
FOR ANY FIXTURE. DOORS MAY SWING INTO THAT PORTION OF MANEUVERING SPACE WHICH DOES NOT
OVERLAP THE CLEARANCE REQUIRED AT A WATER CLOSET.
E - STANDING PERSON DRINKING FOUNTAIN
CBC 11B SECTION 11B-602.7
SPOUT OUTLETS OF DRINKING FOUNTAINS FOR STANDING PERSONS SHALL BE 38 INCHES (965 MM)
MINIMUM AND 43 INCHES (1092 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
CBC 11B SECTION 11B-211.2
NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. WHEN PROVIDED, ONE DRINKING
FOUNTAIN SHALL COMPLY WITH SECTIONS 11B-602.1 THROUGH 11 B- 602.6, 11B-602.8 AND 11 B-602.9 AND
ONE DRINKING FOUNTAIN SHALL COMPLY WITH SECTION 11B-602.7 AND 11B-602.9.
F - ENTRY DOOR MANUEVERING CLEARANCE
CBC 11B SECTION 11B-404.2.4.1
SWINGING DOORS AND GATES SHALL HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE
11B-404.2.4.1.
G - CLEARANCE IN FRONT OF TOILET
CBC 11B SECTION 11B-604.3.1
CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES (1524 MM) MINIMUM MEASURED
PERPENDICULAR FROM THE SIDE WALL AND 56 INCHES (1422 MM) MINIMUM MEASURED PERPENDICULAR
FROM THE REAR WALL. A MINIMUM 60 INCHES (1524 MM) WIDE AND 48 INCHES (1219 MM) DEEP
MANEUVERING SPACE SHALL BE PROVIDED IN FRONT OF THE WATER CLOSET.
H - URINAL
CBC 11B SECTION 11B-605.2
URINALS SHALL BE THE STALL-TYPE OR THE WALL-HUNG TYPE WITH THE RIM 17 INCHES (432 MM)
MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. URINALS SHALL BE 13 1/2 INCHES (343 MM) DEEP
MINIMUM MEASURED FROM THE OUTER FACE OF THE URINAL RIM TO THE BACK OF THE FIXTURE.
1210.3.2 URINAL PARTITIONS
EACH URINAL UTILIZED BY THE PUBLIC OR EMPLOYEES SHALL OCCUPY A SEPARATE AREA WITH WALLS
OR PARTITIONS TO PROVIDE PRIVACY. THE WALLS OR PARTITIONS SHALL BEGIN AT A HEIGHT NOT
MORE THAN 12 INCHES (305 MM) FROM AND EXTEND NOT LESS THAN 60 INCHES (1524 MM) ABOVE THE
FINISHED FLOOR SURFACE. THE WALLS OR PARTITIONS SHALL EXTEND FROM THE WALL SURFACE AT
EACH SIDE OF THE URINAL NOT LESS THAN 18 INCHES (457 MM) OR TO A POINT NOT LESS THAN 6
INCHES (152 MM) BEYOND THE OUTERMOST FRONT LIP OF THE URINAL MEASURED FROM THE FINISHED
BACKWALL SURFACE, WHICHEVER IS GREATER.
I - PIPE AT LAVATORIES
CBC 11B SECTION 11B-606.5
WATER SUPPLY AND DRAIN PIPES UNDER LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE
CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES
UNDER LAVATORIES AND SINKS.
J - SIDE GRAB BAR
CBC 11B SECTION 11B-604.5.1
THE SIDE WALL GRAB BAR SHALL BE 42 INCHES (1067 MM) LONG MINIMUM, LOCATED 12 INCHES (305 MM)
MAXIMUM FROM THE REAR WALL AND EXTENDING 54 INCHES (1372 MM) MINIMUM FROM THE REAR WALL
WITH THE FRONT END POSITIONED 24 INCHES (610 MM) MINIMUM IN FRONT OF THE WATER CLOSET.
K - REAR GRAB BAR LENGTH
CBC 11B SECTION 11B-604.5.2
THE REAR WALL GRAB BAR SHALL BE 36 INCHES (914 MM) LONG MINIMUM AND EXTEND FROM THE
CENTERLINE OF THE WATER CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND 24 INCHES
MINIMUM ON THE OTHER SIDE.
L - OPERABLE PARTS (DOOR)
11B-309.4
OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING,
PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL
BE 5 POUNDS (22.2 N) MAXIMUM
44" MIN. ACCESSIBLE PATH OF TRAVEL
INDICATES EGRESS ROUTE DIRECTON
EXIT SIGN, SINGLE FACE, W/DIRECTIONAL ARROW AS INDICATED,
MOUNTED ON RECESSED CEILING OUTLET BOX.
EXIT SIGN, DOUBLE FACE, W/DIRECTIONAL ARROWS AS INDICATED,
MOUNTED ON RECESSED CEILING OUTLET BOX
EXIT SIGN, SINGLE FACE, NON DIRECTIONAL ARROW, MOUNTED ON
RECESSED CEILING OUTLET BOX.
62'-5" MAX DIAG.
503 SF
COOK
PREP
543 SF
OPEN
DINING
53 SF
RESTROOM
37 SF
STORAGE
TO
T
A
L
L
E
N
G
T
H
6
8
'
-0"
OCCUPANCY: ASSEMBLY A-2 - (TABLE 422.1 CALIFORNIA PLUMBING CODE)
TOTAL OCCUPANT LOAD: 49 (25 MALE, 25 FEMALE)
PLUMBING FIXTURES REQUIRED (TABLE 422.1 PLUMBING CODE)
REQUIRED WATER
CLOSET URINAL LAVATORIES DRINKING
FOUNTAIN SERVICE SINK
MALE 1 1 1
. .
1 N/A 1FEMALE
CPC 422.1
EXCEPTION (3)
IN BUSINESS AND MERCANTILE OCCUPANCIES WITH A TOTAL OCCUPANT LOAD OF 50 OR LESS INCLUDING
CUSTOMERS AND EMPLOYEES, ONE TOILET FACILITY, DESIGNED FOR USE BY NO MORE THAN ONE
PERSON AT A TIME, SHALL BE PERMITTED FOR USE BY BOTH SEXES.
A-2 ASSEMBLY
OCCUPANCY -
RESTAURANTS,
PUBS, LOUNGES,
NIGHTCLUBS
AND BANQUET
HALLS
Male
1: 1-50
2: 51-150
3: 151-300
4: 301-400
Female
1: 1-25
2: 26-50
3: 51-100
4: 101-200
6: 201-300
8: 301-400
Male
1: 1-200
2: 201-300
3: 301-400
4: 401-600
Male
1: 1-150
2: 151-200
3: 201-400
Female
1: 1-150
2: 151-200
3: 201-400
Over 400, add 1
fixture for each
additional 250 males
and 1 fixture for each
125 females.
Over 600,
add 1 fixture
for each
additional
300 males.
Over 400, add 1 fixture
for each additional 250
males and 1 fixture for
each 200 females.
1: 1-250
2: 251-500
3: 501-750
Over 750, add
1 fixture for
each additional
500 persons.
1 service
sink or
laundry
tray
-
PROVIDED ONE UNISEX RESTROOM IS COMPLIANT TO SERVICE THE EXISTING SQUARE
FOOTAGE AND OCCUPANT LOAD.
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATE OF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
3/
9
/
2
0
2
6
4
:
2
2
:
5
7
P
M
G-120
CODE ANALYSIS
2510
Au
t
h
o
r
00 EGRESS LEGEND
EGRESS LEGEND
OCCUPANCY LOAD SCHEDULE
NAME OCC. TYPE AREA DEPARTMENT OCC. LOAD FACTOR
OCC.
LOAD
OPEN DINING 543 SF A2 - ASSEMBLY 15 SF 37
COOK PREP 503 SF B - BUSINESS 50 SF 11
RESTROOM 53 SF NONE 0 SF
STORAGE 37 SF STORAGE 150 SF 1
49
1/4" = 1'-0"CODE ANALYSIS PLAN 1
N
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 03/09/2026
PLUMBING FIXTURE CALCULATIONS
WEST MACARTHUR BLVD
MA
I
N
S
T
R
E
E
T
PROJECT
LOCATION
(E) GAS
STATION
EV
SPACE
(E) TRASH
ENCLOSURE
(E) ROOF
COVER OF
GAS STATION
G-140
5
TYP.
G-140
5
TYP.
G-140
2
TYP.
G-140
14
TYP.
(E) ACCESSIBLE
PARKING
(E) ACCESSIBLE
PARKING
G-140
8
TYP.
(E) DETECTABLE
WARNING, TYP.(E) DETECTABLE
WARNING, TYP.
(E) ACC.
SIGNAGE, TYP.
SEE SHEET G-140
(E) TRANSFORMER(E) TRASH
ENCLOSURE
A-210
3
NO PARKING
(E) GGI TANK
(E) GAS AND
WATER METERS
ARCHITECTURAL
LAYOUT - LAYOUT AND VERIFY ALL DIMENSIONS PRIOR TO START OF WORK. BRING DISCREPANCIES TO
THE ARCHITECT’S ATTENTION.
CONCRETE PAVING SAWCUT
SAWCUT EXISTING REINFORCED CONCRETE WALKWAYS AS REQUIRED FOR NEW WORK. DOWEL AND
EPOXY REBAR AT FACE OF SAWCUT WHERE EXISTING WORK IS TO REMAIN. SEE STRUCTURAL
DRAWINGS. ALL CONCRETE SHALL BE PORTLAND CEMENT CONCRETE WITH ULTIMATE 28 DAY MINIMUM
COMPRESSIVE STRENGTH OF 3,000 PSI UNLESS NOTED OTHERWISE IN OWNER’S GEO-TECHNICAL
REPORT.
NOISE LEVEL COMPLIANCE
COMPLY WITH LOCAL NOISE LEVELS DURING NORMAL BUSINESS HOURS AND OBTAIN PERMISSION FOR
AFTER-HOURS CONSTRUCTION ACTIVITY WHEN APPLICABLE. DIRECT NOISE COMPLAINTS TO THE
CONSTRUCTION MANAGER.
CLEAN JOBSITE
AT THE CONCLUSION OF EACH WORK DAY, LEAVE SITE CLEAN, NEAT AND ORDERLY WITH MATERIALS
AND EQUIPMENT LOCATED TO AVOID SAFETY CONCERNS. CONTRACTOR HAS SOLE RESPONSIBILITY
FOR JOBSITE SAFETY.
GEO-TECHNICAL REPORT
SEE OWNER’S GEOTECHNICAL REPORT FOR SUBGRADE AND COMPACTION CRITERIA UNDER
PAVEMENT.
EXPANSION / CONTROL JOINTS
CONCRETE WALKS SHALL RECEIVE EXPANSION JOINTS AT 15'-0" O.C. MAX AND CONTROL JOINTS AT 5'-0"
O.C. MAX UNLESS OTHERWISE NOTED
PARKING STALL STRIPING
ALL PARKING STALL STRIPING SHALL BE PER LOCAL JURISDICTION STANDARDS.
DIMENSIONS
ALL DIMENSIONS ON SITE PLAN ARE TO BE FACE OF WALL FINISH, FACE OF CONCRETE CURB,
PROPERTY LINE OR CENTERLINE OF PARKING STALL, UNLESS NOTED OTHERWISE.
EXISTING WORK
ALL EXISTING WORK IS TO REMAIN UNLESS NOTED OTHERWISE. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR REPAIRING OR REPLACING AT THE CONTRACTOR’S EXPENSE ANY EXISTING ITEM
DAMAGED BY CONSTRUCTION AND, OR DEMOLITION ACTIVITY. THE DAMAGED ITEMS SHALL BE
RESTORED TO AN “AS-WAS” OR BETTER CONDITION, OR REPLACES AT THE OWNER’S DISCRETION.
WASTE MANAGEMENT
CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTION WASTE MANAGEMENT COMPLIANCE DEFINED BY
LOCAL GREEN BUILDING ORDNANCE(S), INCLUDING BUT NOT LIMITED TO SORTING AND SEPARATING
MATERIALS DERIVED FROM CONSTRUCTION AND DEMOLITION DEBRIS INCLUDING BUT NOT LIMITED TO
CONCRETE, REINFORCING STEEL AND ASPHALT.
TRAFFIC & PEDESTRIAN ACCESS
SCHEDULE CONSTRUCTION WASTE MATERIAL REMOVAL IN A MANNER TO INSURE MINIMUM
INTERFERENCE WITH VEHICLE TRAFFIC AND PEDESTRIAN ACCESS INCLUDING ADJACENT PROPERTIES
WHEN APPLICABLE, PER LOCAL REQUIREMENTS.
SITE DRAINAGE
CONTRACTOR SHALL MAINTAIN NECESSARY TEMPORARY SITE DRAINAGE DURING DEMOLITION AND
CONSTRUCTION ACTIVITY.
LANDSCAPE PROTECTION
PROTECT EXISTING PLANTING AREAS INCLUDING TREES, SHRUBS, TURF AND IRRIGATION SYSTEM
SHOWN TO REMAIN. COORDINATE NEW WORK WITH EXISTING AS-BUILT FIELD CONDITIONS. SEE
LANDSCAPE DRAWINGS.
CONSTRUCTION BARRICADES
CONTRACTOR BEARS SOLE RESPONSIBILITY FOR CONSTRUCTION BARRICADES, PROTECTIVE
CANOPIES AND OTHER FORMS OF PROTECTION AS REQUIRED TO PROTECT OWNER’S PERSONNEL,
BUILDING TENANTS AND THE GENERAL PUBLIC FROM INJURY DURING CONSTRUCTION.
DAMAGE REPAIR
PROMPTLY REPAIR DAMAGE WHEN OCCURS AT NO ADDITIONAL COST TO OWNER.
DUST CONTROL
USE TEMPORARY ENCLOSURES OR OTHER SUITABLE METHODS SUCH AS WATERING TO CONTROL
DUST IN ACCORDANCE WITH LOCAL JURISDICTION.
EQUIPMENT
EQUIPMENT STORED ON SITE AWAITING INSTALLATION SHALL BE PROTECTED FROM PHYSICAL
DAMAGE.
PROPERTY LINE
LIMIT OF WORK
ACCESSIBLE PATH OF TRAVEL
ACCESSIBLE ROUTE TO PUBLIC RIGHT OF WAY
PRIMARY BUILDING ENTRANCE
SECONDARY BUILDING ENTRANCES
INTERIOR AND ROOF RENOVATION
AREA N.I.C.
AREA OF IMPROVEMENT
KEYNOTE TAGD20 / 10
(E) ROOF WELL AND
MECHANICAL UNIT
19' - 4"
11
'
-
8
"
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATE OF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
3/
9
/
2
0
2
6
4
:
2
2
:
5
8
P
M
A-010
SITE PLAN
2510
Au
t
h
o
r
1" = 20'-0"SITE PLAN 1
GENERAL NOTES
SITE LEGEND
N
(E) SITE PLAN FROM OTHER PERMIT SET. NOT TO SCALE. FOR REFERENCE ONLY
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 03/09/2026
TT
s
FM
FS
T
P
DP
MECH. CONTRACTOR
ELEC. CONTRACTOR
FURNISHED AND INSTALLED BY
BOTH MECH. AND ELEC.
CONTRACTORS
M
E
M
E
ELECTRONIC WALL THERMOSTAT
TOTAL LINE DEBONAIR MODEL 220 HEATING
AND COOLING T-STAT WITH (7) DAY TIME
CLOCK, SOFT START, FOUR HOUR
OVERRIDE, PURGE MODE, DUAL DIGITAL
SET POINTS, AND TEMPERATURE DEAD
BAND.
SUPPLY DUCT
DUCT MOUNTED SMOKE
DETECTOR IN SUPPLY AIR
DUCT. A/C UNITS WITH SUPPLY
CFM OF 2,000 OR HIGHER
A/C UNIT
POWER E
120V/1PH/60
HZ CONTROL
POWER
ED/S
M
E
G
W2
W1
Y2
Y1
R
C
UNIT
TERMINAL
STRIP
CONTROL WIRING
FAN
HEAT 2
HEAT 1
COOL 2
COOL 1
24 VAC
24 VAC (COMMON)
G
W2
W1
Y2
Y1
R
C
FAN ON
COOL
HEAT
PROGRAM
72 T
UNIT CONTROL
TRANSFORMER
SYMBOL
DOUBLE LINE DESCRIPTIONSYMBOL
SINGLE LINE
DUCTWORK, SIZE AS INDICATED
DUCTWORK, WITH SOUNDLINING
VANED ELBOW
SUPPLY DUCT TURNING UP AND DOWN
RETURN DUCT TURNING UP AND DOWN
EXHAUST DUCT TURNING UP AND DOWN
DUCT RISE/DROP IN AIRFLOW DIRECTION
DUCT TRANSITION, SQUARE TO SQUARE
DUCT TRANSITION, SQUARE TO ROUND
DUCT CAPPED
45 DEGREE TAP
CONICAL TAP
SPUN-IN RUNOUT FITTING W/ FLEX. & VD
FLEXIBLE DUCT
MANUAL VOLUME DAMPER
FIRE DAMPER
SMOKE DAMPER
COMBINATION FIRE/SMOKE DAMPER
BACKDRAFT DAMPER
MOTORIZED DAMPER
SUPPLY AIR DIFFUSER
EXHAUST AIR DIFFUSER
UNDERCUT DOOR
DOOR LOUVER
THERMOSTAT, MASTER THERMOSTAT
TEMPERATURE SENSOR
20x12 20x12
20x12 20x12
R/D R/D
FLEXIBLE CONNECTION
HUMIDISTAT
HUMIDITY SENSOR
DUCT SMOKE DETECTOR
CARBON DIOXIDE SENSOR
CARBON MONOXIDE SENSOR
STATIC PRESSURE SENSOR
UC
DL
12x12
DUCT ACCESS DOORAD
AD
AIR FLOW MEASURING STATION
SUPPLY AIR FLOW DIRECTION
OUTSIDE AIR FLOW DIRECTION
RETURN/EXHAUST AIR FLOW DIRECTION
OA
,
FREEZESTAT
MANUAL TIMER SWITCH
SWITCH OR TOGGLE SWITCH
HAND/OFF/AUTO SWITCH
UN-VANED ELBOW
VANED TEE
UN-VANED TEE
BAROMETRIC DAMPER
LINEAR SLOT DIFFUSER
RADIUS ELBOW
RETURN AIR DIFFUSER
HOA
TM
S
FD
SD
FSD
BDD
MD
BD
FD
SD
FSD
BDD
MD
BD
S SD
SINGLE DUCT VAV BOX WITH REHEAT COIL
SINGLE DUCT VAV BOX WITHOUT REHEAT COIL
DUCT CONTINUATION
DAMPER, OPPOSED BLADE
DAMPER, PARALLEL BLADE
FILTER
HUMIDIFIER
ZCDZCD ZONE CONTROL DAMPER
AFMS
SP
CO
CO2
FZ
H
TS
HS
@ AT
A AIR
AAV AUTOMATIC AIR VENT
ABV ABOVE
AC AIR CONDITIONING
ACU AIR CONDITIONING UNIT
ACCU AIR COOLED CONDENSING UNIT
AD ACCESS DOOR
ADJ ADJUST, ADJUSTABLE
ADA AMERICANS WITH
DISABILITIES ACT
AF AIRFOIL, ANTI-FREEZE
AFF ABOVE FINISHED FLOOR
AFMS AIR FLOW MONITORING
STATION
AHU AIR HANDLING UNIT
AI ANALOG INPUT
ALUM ALUMINUM
AO ANALOG OUTPUT
AP ACCESS PANEL
APD AIR PRESSURE DROP
APPROX APPROXIMATELY
ARCH ARCHITECTURAL
ARU AIR ROTATION UNIT
AS AIR SEPARATOR
ASHP AIR SOURCE HEAT PUMP
AST ABOVEGROUND STORAGE TANK
ATC AUTOMATIC
TEMPERATURE CONTROL
ATV ATMOSPHERIC VENT
AV ANALOG VALVE
AVG AVERAGE
BAS BUILDING AUTOMATION SYSTEM
BDD BACKDRAFT DAMPER,
BOILER BLOWDOWN
BF BOILER FEED
BFP BACKFLOW PREVENTER
BLW BELOW
BLDG BUILDING
BMS BUILDING MANAGEMENT SYSTEM
BOD BOTTOM OF DUCT, BASIS OF DESIGN
BOL BOTTOM OF LOUVER
BOT BOTTOM
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNITS PER HOUR
C COMMON
CA COMPRESSED AIR
CC COOLING COIL
CD CONDENSATE DRAIN
CFM CUBIC FEET PER MINUTE
CH CHILLER
CHWR CHILLED WATER RETURN
CHWS CHILLED WATER SUPPLY
CI CAST IRON
CL CENTER LINE
CLG COOLING
CLNG CEILING
CNG COMPRESSED NATURAL GAS
CO CLEANOUT, CARBON MONOXIDE
CO2 CARBON DIOXIDE
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONT CONTINUATION
CONT'D CONTINUED
CP CONDENSATE PUMP
CPVC CHLORINATED POLYVINYL CHLORIDE
CRAC COMPUTER ROOM AIR CONDITIONER
CRAH COMPUTER ROOM AIR HANDLER
CV CONTROL VOLUME, CHECK VALVE
CT COOLING TOWER
CW COLD WATER
CWR CONDENSER WATER RETURN
CWS CONDENSER WATER SUPPLY
Cx COMMISSIONING
CxA COMMISSIONING AUTHORITY
(D)DEMOLISH, REMOVE
D DRAIN, DEPTH
DAT DISCHARGE AIR TEMPERATURE
DB DRY BULB TEMPERATURE, DECIBELS
DCW DOMESTIC COLD WATER
DDC DIRECT DIGITAL CONTROL
DEG, ° DEGREES
DEH DEHUMIDIFIER
DEPT DEPARTMENT
DESG DESIGNATION
DI DIGITAL INPUT
DIA, ø DIAMETER
DIFF DIFFERENTIAL, DIFFERENCE
DISC DISCONNECT
DN DOWN
DO DIGITAL OUTPUT
DP DIFFERENTIAL PRESSURE
DTWR DUAL TEMPERATURE WATER RETURN
DTWS DUAL TEMPERATURE WATER SUPPLY
DV DIGITAL VALVE
DWG DRAWING
DX DIRECT EXPANSION
(ER) EXISTING RELOCATED
(EX) EXISTING TO REMAIN
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
ECM ELECTRONICALLY
COMMUNICATED MOTOR
EF EXHAUST FAN
EFF EFFICIENCY
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC, ELECTRICAL
ELEV ELEVATOR
EMS ENERGY MANAGEMENT SYSTEM
(ER) EXISTING RELOCATED
ESP EXTERNAL STATIC PRESSURE
ET EXPANSION TANK
EWB ENTERING WET BULB TEMPERATURE
EWT ENTERING WATER TEMPERATURE
EXT EXTERIOR
°F DEGREES FAHRENHEIT
(F) FUTURE
FSD COMBINATION
FIRE/SMOKE DAMPER
FD FLOOR DRAIN, FIRE
DAMPER
FDC FIRE DEPARTMENT
CONNECTION
FDR FLOOR DRAIN
FF FINISHED FLOOR
FG FUEL GAS
FLR FLOOR
FLA FULL LOAD AMPS
FLEX FLEXIBLE
FO FUEL OIL
FOB FLAT ON BOTTOM
FOF FUEL OIL FILL
FOG FUEL OIL GAUGE
FOR FUEL OIL RETURN
FOS FUEL OIL SUPPLY
FOT FLAT ON TOP
FOV FUEL OIL VENT
FRP FIBERGLASS
REINFORCED PLASTIC
FPM FEET PER MINUTE
FPS FEET PER SECOND
FS FLOW SWITCH
FM FLOW METER
FT, ‘ FOOT, FEET
FT HD FEET OF HEAD
FZ FREEZE, FREEZSTAT
GA GAUGE
GAL GALLON, GALLONS
GALV GALVANIZED
GEN GENERATOR
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GWR GLYCOL WATER RETURN
GWS GLYCOL WATER SUPPLY
H HEIGHT
H2O WATER
HB HOSE BIB
HC HEATING COIL
HCU HUMIDIFICATION CONTROL UNIT
HGB HOT GAS BYPASS
HORIZ HORIZONTAL
HP HORSEPOWER
HPCR HIGH PRESSURE
CONDENSATE RETURN
HPS HIGH PRESSURE STEAM
HTG HEATING
HUM HUMIDIFIER
HWR HOT WATER RETURN
HWS HOT WATER SUPPLY
HX HEAT EXCHANGER
HZ HERTZ (CYCLES PER SECOND)
ID INSIDE DIAMETER
IGV INLET GUIDE VANE
IN, “ INCH, INCHES
IN WG INCHES OF WATER GAUGE
INFO INFORMATION
INT INTERIOR
INV INVERT ELEVATION
ISOL ISOLATION
IW INDUSTRIAL WASTE
KW KILOWATTS
L LENGTH, LONG
LAT LEAVING AIR TEMPERATURE
LAV LAVATORY
LBS POUNDS
LBS/HR POUNDS PER HOUR
LEED LEADERSHIP IN ENERGY &
ENVIRONMENTAL DESIGN
LP LIQUID PROPANE
LPCR LOW PRESSURE
CONDENSATE RETURN
LPS LOW PRESSURE STEAM
LRA LOAD RATED AMPS
LWT LEAVING WATER TEMPERATURE
M METER
MA MIXED AIR
MAV MANUAL AIR VENT
MAX MAXIMUM
MBH THOUSAND BRITISH THERMAL
UNITS PER HOUR
MCA MINIMUM CIRCUIT AMPACITY
MECH MECHANICAL
MFR MANUFACTURER
MO MOTOR OIL
MOD MOTOR OPERATED
DAMPER, MODULATING
MIN MINIMUM
MPCR MEDIUM PRESSURE
CONDENSATE RETURN
MPS MEDIUM PRESSURE STEAM
MTD MOUNTED
MTG MOUNTING
MUW MAKE UP WATER
N/A NOT APPLICABLE
NC NORMALLY CLOSED,
NOISE CRITERIA
NIC NOT IN CONTRACT
NFPA NATIONAL FIRE
PROTECTION AGENCY
NG NATURAL GAS
No NUMBER
NO NORMALLY OPENED
NOM NOMINAL
NTS NOT TO SCALE
OA OUTSIDE AIR
OAT OUTSIDE AIR TEMPERATURE
OC ON CENTER
OED OPEN ENDED DUCT
OFD OVERFLOW DRAIN
OI OIL INTERCEPTOR
OSD OPEN SITE DRAIN
OS&Y OUTSIDE STEM AND YOKE VALVE
OVH OVERHEAD
OWS OIL WATER SEPARATOR
% PERCENT
P PUMP
PC PUMPED CONDENSATE
PCR PUMP (STEAM)
CONDENSATE RETURN
PD PRESSURE DROP
PH PHASE
PLBG PLUMBING
PNEU PNEUMATIC
POS POSITION
PROP PROPELLER
PRESS PRESSURE
PRV PRESSURE REDUCING VALVE
PS PRESSURE SWITCH
PSI POUNDS PER SQUARE INCH
PSIG POUNDS PER SQUARE INCH GAUGE
PVC POLYVINYL CHLORIDE
(RX) REMOVE EXISTING
R RISE
RA RETURN AIR
RD ROOF DRAIN
REF REFRIGERANT
REQ'D REQUIRED
RH RELATIVE HUMIDITY
RL REFRIGERANT LIQUID
RLA RATED LOAD AMPS
RM ROOM
RPM REVOLUTIONS PER MINUTE
RS REFRIGERANT SUCTION
S SWITCH
SM SHEET METAL
SA SUPPLY AIR
SAN SANITARY
SAT SATURATED, SUPPLY AIR TEMPERATURE
SD SMOKE DETECTOR, SMOKE DAMPER
SENS SENSIBLE
SF SUPPLY FAN, SQUARE FEET
SHT SHEET
SL SOUND LINING
SP STATIC PRESSURE
SPR SPRINKLER
SPEC SPECIFICATION
SQ SQUARE
SQ FT SQUARE FOOT, SQUARE FEET
S/S START/STOP
SS STAINLESS STEEL
STD STANDARD
STL STEEL
ΔT TEMPERATURE DIFFERENTIAL
TEMP TEMPERATURE, TEMPORARY
TD TRANSFER DUCT
TG TRANSFER GRILLE
TOD TOP OF DUCT
TOL TOP OF LOUVER
TSP TOTAL STATIC PRESSURE
TYP TYPICAL
UC UNDERCUT DOOR
UH UNIT HEATER
UL UNDERWRITERS LABORATORIES
UON UNLESS OTHERWISE NOTED
UST UNDERGROUND STORAGE TANK
V VOLTS, VENT
VAR VARIABLE
VAV VARIABLE AIR VOLUME
VCO VERTICAL CLEAN OUT
VD VOLUME DAMPER
VEL VELOCITY
VENT VENTILATION
VERT VERTICAL
VFD VARIABLE FREQUENCY DRIVE
VIB VIBRATION
VRF VARIABLE REFRIGERANT FLOW
VSD VARIABLE SPEED DRIVE
VTR VENT THROUGH ROOF
W WIDTH, WIDE
W/WITH
W/O WITHOUT
WB WET BULB TEMPERATURE
WC WATER COLUMN
WG WATER GAUGE
WH WATER HEATER
WMS WIRE MESH SCREEN
WPD WATER PRESSURE DROP
WSHP WATER SOURCE HEAT PUMP
WT WEIGHT
ZN ZONE
SYMBOL DESCRIPTION
CONDENSATE DRAIN
CHILLED WATER RETURN
CHILLED WATER SUPPLY
CONDENSER WATER RETURN
CONDENSER WATER SUPPLY
COMPRESSED AIR
HEATING HOT WATER RETURN
HEATING HOT WATER SUPPLY
LOW PRESSURE STEAM
HIGH PRESSURE STEAM
MEDIUM PRESSURE STEAM
NATURAL GAS
REFRIGERANT LIQUID
REFRIGERANT SUCTION
REFRIGERANT DISCHARGE
STEAM
STEAM CONDENSATE RETURN
GLYCOL WATER RETURN
GLYCOL WATER SUPPLY
COLD WATER
MAKE UP WATER
GAS
PIPING TURNING DOWN
PIPE BRANCH TOP TAKEOFF
CAP
PIPE RISER UP/DOWN
PIPING TURNING UP
PIPE BRANCH BOTTOM TAKEOFF
TEE DOWN
FLOW DIRECTION
R/D
PIPE SLOPE RISE/DROP
CONCENTRIC REDUCER/INCREASER
UNION
,PIPE CONTINUATION
PIPE ANCHOR
PIPE GUIDE
FLEXIBLE PIPE CONNECTOR
STEAM TRAP
EXPANSION LOOP (WxH)H
W
EXPANSION JOINTEJ
,
STM
SC
RS
RL
RD
NG
MPS
MUW
LPS
HPS
HHWS
HHWR
GWS
GWR
G
CWS
CWR
CW
CHWS
CHWR
CD
CA
VALVE IN VERTICAL PIPE
BLIND FLANGE
PUMPED STEAM CONDENSATE RETURNPSC
DIFFERENTIAL PRESSURE TRANSDUCER
TEMPERATURE SENSOR
PRESSURE SENSOR
FLOW SWITCH
STRAINER WITH DRAIN VALVE AND CAP
FLOW METER
GEN. SHUTOFF VALVE (BALL, GATE, BUTTERFLY)
PRESSURE GAUGE WITH COCK
GATE VALVE
PUMP
OUTSIDE STEM & YOKE VALVE
CHECK VALVE
BALL VALVE
BUTTERFLY VALVE
GAS COCK
GLOBE VALVE
THERMOMETER
STRAINER
PRESSURE/TEMPERATURE TEST PORT
PRESSURE REDUCING VALVE
CALIBRATED BALANCING VALVE
CONTROL VALVE, TWO-WAY (ELECTRIC)
CONTROL VALVE, THREE-WAY (ELECTRIC)
THREE-WAY MANUAL VALVE
SOLENOID VALVE
AUTOMATIC AIR VENT (EXTEND TO DRAIN)
MANUAL AIR VENT
AQUASTAT
AAV
MAV
RELIEF/SAFETY VALVE
VENTURI FLOW METER
BALANCING VALVE
HOSE BIBB VALVE
PRESSURE REGULATOR
SYMBOL DESCRIPTION
SYMBOL DESCRIPTION
POINT OF CONNECTION
POINT OF DISCONNECTION
SHEET KEYNOTE
DRAWING REVISION NUMBER
NEW WORK LINEWEIGHT
EXISTING LINEWEIGHT
FUTURE LINEWEIGHT
DEMOLITION LINEWEIGHT
#
#
#SHEET DEMOLITION KEYNOTE
1
M301
INDICATES PLAN/DETAIL NUMBER
PLAN/DETAIL TITLE
SCALE (AS REQUIRED)
INDICATES PLAN/DETAIL NUMBER
INDICATES DRAWING ON
WHICH
DRAWING SECTION APPEARS
DIFFUSER, REGISTER, OR GRILLE
DESIGNATION AND AIRFLOW TAG150
D1 TYPE
CFM
EQUIPMENT TAG
EQUIPMENT NUMBER
EQUIPMENT DESIGNATION
TITLE#
SCALE:
E-1
VAV
1
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
NOT ALL ABBREVIATIONS, LINE TYPES, OR SYMBOLS MAY APPEAR ON CONTRACT DOCUMENTS.
WHERE USED, THE TERM "PROVIDE" SHALL MEAN BOTH "FURNISH AND INSTALL".
CONTRACTOR SHALL FURNISH LABOR, MATERIALS, EQUIPMENT, AND TRANSPORTATION AS
REQUIRED TO PROPERLY INSTALL ALL NEW HVAC SYSTEMS OR RELATED COMPONENTS AS
INDICATED ON PLANS AND SPECIFIED.
THIS CONTRACTOR SHALL DOCUMENT AND RELAY ANY MAJOR DEVIATIONS FROM THE DESIGN
DOCUMENTS, AND ATTAIN APPROVAL FROM THE MECHANICAL ENGINEER BEFORE PROCEEDING. AS-
BUILT COPIES SHALL BE PROVIDED INDICATING ALL CHANGES / DEVIATIONS MADE DURING
CONSTRUCTION.
NO PIPING, EQUIPMENT, ETC. SHALL BE REMOVED, DISCONNECTED OR SHUT DOWN WITHOUT PRIOR
REVIEW WITH THE OWNER TO CONFIRM THAT AREAS TO REMAIN IN OPERATION WILL NOT BE
AFFECTED. IF ANY AREAS NOT WITHIN THE SCOPE OF WORK ARE AFFECTED BY ANY SHUTDOWN,
REMOVAL OR DISCONNECTION, SUFFICIENT ADVANCE NOTICE MUST BE GIVEN TO THE OWNER
INDICATING WHICH AREAS WILL BE AFFECTED, WHEN THE PROPOSED SHUTDOWN WILL OCCUR, AND
FOR HOW LONG A PERIOD OF TIME.
THE ARRANGEMENT OF EQUIPMENT AND PIPING SHOWN ON THE DRAWINGS IS BASED UPON
INFORMATION AVAILABLE TO THE ENGINEER AT THE TIME OF DESIGN AND IS NOT INTENDED TO
SHOW EXACT DIMENSIONS PECULIAR TO A SPECIFIC MANUFACTURER. THE DRAWINGS ARE, IN PART,
DIAGRAMMATIC AND SOME FEATURES OF THE ILLUSTRATED EQUIPMENT INSTALLATION MAY
REQUIRE REVISION TO MEET ACTUAL EQUIPMENT INSTALLATION REQUIREMENTS. STRUCTURAL
SUPPORTS, FOUNDATIONS, CONNECTED PIPING, VALVES AND ELECTRICAL CONDUIT SPECIFIED MAY
HAVE TO BE ALTERED TO ACCOMMODATE THE EQUIPMENT PROVIDED.
EXISTING MATERIALS THAT ARE REMOVED SHALL NOT BE REUSED IN NEW SYSTEMS, EXCEPT WHERE
INDICATED AS BEING RELOCATED
ALL EQUIPMENT SHALL BE INSTALLED IN STRICT COMPLIANCE WITH THE MANUFACTURER'S WRITTEN
INSTRUCTIONS.
GALVANIZED SHEET METAL SHALL BE PROVIDED FOR ALL HVAC DUCT SYSTEMS, AND CONSTRUCTED
/ SUPPORTED / INSTALLED IN ACCORDANCE WITH THE 2025 CALIFORNIA MECHANICAL CODE AND THE
LATEST SMACNA STANDARDS.
ALL PIPING SHALL BE INSTALLED AS INDICATED ON THE DRAWINGS IN A NEAT WORKMANSHIP-LIKE
MANNER AND BE SUPPORTED AS REQUIRED BY CODES. PIPING SHALL BE SET UP AND DOWN AND
OFFSET AS REQUIRED TO SUIT FIELD CONDITIONS. DIELECTRIC COUPLINGS SHALL BE USED WHERE
DISSIMILAR METALS ARE JOINED.
THIS CONTRACTOR SHALL PROVIDE ALL NECESSARY SUPPORTS FOR FIXTURES, DUCTWORK, PIPING,
AND MECHANICAL EQUIPMENT, IN ORDER TO COMPLY WITH SEISMIC REQUIREMENTS AS OUTLINED
BY THE LATEST EDITION(S) OF THE CALIFORNIA BUILDING CODE, SMACNA INSTALLATION STANDARDS,
AND ALL RELATED LOCAL ORDINANCES.
DRAWINGS SHALL BE CONSIDERED DIAGRAMMATIC AND ARE INTENDED TO INDICATE CAPACITY, SIZE,
APPROXIMATE LOCATION AND GENERAL ARRANGEMENT. WHILE THE DRAWINGS ARE GENERALLY TO
SCALE AND ARE AS ACCURATE AS THE SCALE WILL PERMIT, DIMENSIONS SHALL BE CONFIRMED IN
THE FIELD.
THE CONTRACTOR SHALL COMPLY WITH THE LAWS, ORDINANCES, RULES AND REGULATIONS OF
LOCAL AND STATE GOVERNMENTAL AUTHORITIES; OF THE NATIONAL FIRE PROTECTION
ASSOCIATION AS INTERPRETED BY THE ENFORCING AUTHORITY HAVING JURISDICTION; AND OF
PUBLIC UTILITIES HAVING CONNECTION WITH ANY OF THE SYSTEMS HEREIN SPECIFIED.
THE CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED BY THE
CONTRACT AND PAY FOR ALL OTHER COSTS IN CONNECTION WITH THE WORK. CERTIFICATES SHALL
BE IN DUPLICATE AND SHALL BE DELIVERED TO THE OWNER.
THE SITE, LOCATION, AND ROUTING OF SYSTEMS INDICATED TO HAVE NEW CONNECTIONS MADE TO
THEM ARE SHOWN AS ACCURATELY AS FIELD CONDITIONS PERMIT. CONTRACTOR SHALL VISIT THE
SITE AND THOROUGHLY EXAMINE THE CONTRACT DRAWINGS. ALL EXISTING CONDITIONS SHALL BE
EXAMINED AND THEIR EXACT LOCATIONS VERIFIED. THE CONTRACTOR SHALL REPORT TO THE
ENGINEER ANY CONDITIONS WHICH MIGHT MAKE INSTALLATION OF REQUIRED EQUIPMENT A
PROBLEM.
THE CONTRACTOR SHALL INSTALL AND CONNECT EQUIPMENT AND MATERIALS IN ACCORDANCE
WITH THE BEST ENGINEERING PRACTICE AND, UNLESS OTHERWISE SHOWN OR SPECIFIED, FOLLOW
THE MANUFACTURER'S PRINTED INSTALLATION REQUIREMENTS AND RECOMMENDATIONS, AND
FURNISH AND INSTALL REQUIRED AUXILIARY ITEMS TO PROVIDE A COMPLETE INSTALLATION.
THE CONTRACTOR SHALL REMOVE EQUIPMENT AS SHOWN ON THE DRAWINGS TO A DESIGNATED
LOCATION AT THE PROJECT SITE. AFTER THE EQUIPMENT HAS BEEN ASSEMBLED FOR THE OWNER'S
INSPECTION AND POSSIBLE RETENTION, ALL EQUIPMENT NOT TO BE RETAINED BY THE OWNER
SHALL BE REMOVED FROM THE SITE BY THE CONTRACTOR.
COORDINATE WITH OTHER TRADES TO AVOID INTERFERENCE AMONG MECHANICAL, ELECTRICAL,
ARCHITECTURAL AND STRUCTURAL, PLUMBING, ETC. PROVIDE NECESSARY OFFSETS IN PIPING,
DUCTWORK AND FITTINGS ETC., REQUIRED TO PROPERLY INSTALL WORK WITHOUT INTERFERENCES.
BUILDING SYSTEMS SHALL REMAIN IN SERVICE UNLESS INDICATED OTHERWISE. OUTAGES OR
INTERRUPTIONS SHALL BE KEPT TO A MINIMUM DURATION. NOTIFY THE OWNER 48 HOURS IN
ADVANCE OF ANY OUTAGE OR INTERRUPTION.
THE CONTRACTOR SHALL LOCATE EQUIPMENT WHICH MUST BE SERVICED, OPERATED OR
MAINTAINED IN FULLY ACCESSIBLE POSITIONS. FURNISH ACCESS DOORS AS REQUIRED FOR BETTER
ACCESSIBILITY. MINOR DEVIATIONS FROM DRAWINGS MAY BE MADE TO ALLOW FOR ACCESSIBILITY,
BUT CHANGES OF MAGNITUDE WHICH INVOLVE EXTRA COSTS SHALL NOT BE MADE WITHOUT
WRITTEN APPROVAL.
ALL DIMENSIONS FOR EXISTING PIPING AND DUCTWORK SHALL BE VERIFIED IN THE FIELD BY THE
CONTRACTOR PRIOR TO CONSTRUCTION, WHERE NEW WORK CONNECTIONS ARE INDICATED. NEW
DUCT DIMENSIONS SHOWN ARE INSIDE CLEAR DIMENSIONS.
OPENINGS REMAINING IN EXISTING PIPING/DUCTWORK AS A RESULT OF DEMOLITION SHALL BE
SEALED WITH AN AIRTIGHT/WATERTIGHT SHEET METAL CAP. WHERE EXISTING SYSTEMS ARE
INSULATED, WORK SHALL INCLUDE REPAIR AND REPLACEMENT OF INSULATION EITHER DAMAGED OR
REMOVED AS A RESULT OF DEMOLITION.
PIPING SCOPE REQUIREMENTS: HORIZONTAL DRAINAGE PIPING SHALL BE INSTALLED IN UNIFORM
ALIGNMENT AT UNIFORM SLOPES. THE MINIMUM SLOPE OF HORIZONTAL DRAINAGE PIPE SHALL BE IN
ACCORDANCE WITH THE FOLLOWING:
SIZE (INCHES)MINIMUM SLOPE (INCHES PER FOOT)
2-1/2 OR LESS
3 TO 68 OR
LARGER
1/4
1/8
1/16
12.PIPING AND DUCT SUPPORTS SHALL BE AS FOLLOWS:
A. ALL BRACING OF DUCTS AND PIPING SHALL BE INSTALLED IN ACCORDANCE WITH SMACNA
GUIDELINES, OR AS DETAILED AND SPECIFIED HEREIN.
B. WHERE BRACING DETAILS ARE NOT SHOWN ON THE DRAWINGS OR IN THE GUIDELINES,
THE FIELD INSTALLATION SHALL BE SUBJECT TO THE APPROVAL OF THE MECHANICAL
ENGINEER.
C. A COPY OF THE GUIDELINES PUBLISHED BY SMACNA SHALL BE PROVIDED BY THE
CONTRACTOR AND KEPT ON THE JOB AT ALL TIMES.
13.
14.
15.
16.
THIS CONTRACTOR SHALL NOT BORE, NOTCH, CUT, OR PENETRATE INTO A STRUCTURAL MEMBER
WITHOUT WRITTEN APPROVAL FROM A DESIGNATED STRUCTURAL ENGINEER AND THE OWNER.
INSTALL MANUAL VOLUME DAMPERS WITHIN DUCT BRANCHES TO BALANCE AIR FLOW CFM. ON
INSULATED DUCTS, MOUNT DAMPER REGULATOR ON 2" STAND-OFF BRACKET TO CLEAR INSULATION.
PER 2025 CMC 608.1 AUTOMATIC SHUT OFF OF AIR HANDLER SHALL BE DONE UPON THE DETECTION
OF SMOKE IN THE MAIN SUPPLY AIR DUCT SERVED BY THE AIR HANDLER.
ALL MATERIAL EXPOSED WITHIN RA PLENUMS SHALL BE NON-COMBUSTIBLE OR SHALL HAVE A FLAME
SPREAD INDEX NOT GREATER THAN 25 AND SMOKE DEVELOPED INDEX NOT GREATER THAN 50.
COMPLY WITH CMC-602.2.
17.EQUIPMENT ANCHORAGE NOTES:
ALL MECHANICAL, PLUMBING, AND ELECTRICAL COMPONENTS SHALL BE ANCHORED AND INSTALLED
PER THE DETAILS ON THE APPROVED CONSTRUCTION DOCUMENTS. WHERE NO DETAIL IS
INDICATED, THE FOLLOWING COMPONENTS SHALL BE ANCHORED OR BRACED TO MEET THE FORCE
AND DISPLACEMENT REQUIREMENTS PRESCRIBED IN THE CBC, SECTIONS 1616A.1.18 THROUGH
1616A.1.26 AND ASCE 7-10 CHAPTER 6 AND 30.
A. ALL PERMANENT EQUIPMENT AND COMPONENTS.
B. TEMPORARY OR MOVABLE EQUIPMENT THAT IS PERMANENTLY ATTACHED (E.G. HARD
WIRED) TO THE BUILDING UTILITY SERVICES SUCH AS ELECTRICITY, GAS OR WATER.
C. MOVABLE EQUIPMENT WHICH IS STATIONED IN ONE PLACE FOR MORE THAN 8 HOURS AND
HEAVIER THAN 400 POUNDS ARE REQUIRED TO BE ANCHORED WITH TEMPORARY
ATTACHMENTS.
THE ATTACHMENT OF THE FOLLOWING MECHANICAL AND ELECTRICAL COMPONENTS SHALL BE
POSITIVELY ATTACHED TO THE STRUCTURE, BUT NEED NOT BE DETAILED ON THE PLANS. THESE
COMPONENTS SHALL HAVE FLEXIBLE CONNECTIONS PROVIDED BETWEEN THE COMPONENT AND
ASSOCIATED DUCTWORK, PIPING, AND CONDUIT:
A. COMPONENTS WEIGHING LESS THAN 400 POUNDS AND HAVE A CENTER OF MASS LOCATED
4 FEET OR LESS ABOVE THE ADJACENT FLOOR OR ROOF LEVEL THAT DIRECTLY SUPPORT
THE COMPONENT.
B. COMPONENTS WEIGHING LESS THAN 20 POUNDS, OR IN THE CASE OF DISTRIBUTED
SYSTEMS, LESS THAN 5 POUNDS PER FOOT, WHICH ARE SUSPENDED FROM A ROOF OR
FLOOR OR HUNG FROM A WALL.
FOR THOSE ELEMENTS THAT DO NOT REQUIRE DETAILS ON THE APPROVED DRAWINGS, THE
INSTALLATION SHALL BE SUBJECT TO THE APPROVAL OF THE STRUCTURAL ENGINEER OF RECORD
AND THE DSA DISTRICT STRUCTURAL ENGINEER. THE PROJECT INSPECTOR WILL VERIFY THAT ALL
COMPONENTS AND EQUIPMENT HAVE BEEN ANCHORED IN ACCORDANCE WITH ABOVE
REQUIREMENTS.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
ALL MECHANICAL COMPONENTS SHALL BE ANCHORED AND INSTALLED PER DETAILS ON APPROVED
CONSTRUCTION DOCUMENTS AND CBC, SECTIONS 1616A.1.18 THROUGH 1617A.1.26.
AIR MOVING SYSTEMS SUPPLY AIR IN EXCESS OF 2,000 CUBIC FEET PER MINUTE TO ENCLOSED
SPACES WITHIN BUILDINGS SHALL BE EQUIPPED WITH AN AUTOMATIC SHUTOFF. AUTOMATIC
SHUTOFF SHALL BE ACCOMPLISHED BY INTERRUPTING THE POWER SOURCE OF THE AIR-MOVING
EQUIPMENT UPON DETECTION OF SMOKE IN THE MAIN SUPPLY-AIR DUCT SERVED BY SUCH
EQUIPMENT. SMOKE DETECTORS SHALL BE LABELED BY AN APPROVED AGENCY FOR AIR-DUCT
INSTALLATION AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S
INSTALLATION INSTRUCTIONS. SUCH DEVICES SHALL BE COMPATIBLE WITH THE OPERATING
VELOCITIES, PRESSURES, TEMPERATURES, AND HUMIDITIES OF THE SYSTEM. WHERE FIRE
DETECTION OR ALARM SYSTEMS ARE PROVIDED FOR THE BUILDING. THE SMOKE DETECTORS
REQUIRED BY THIS SECTION SHALL BE SUPERVISED BY SUCH SYSTEMS.
ALL CONTROL WIRES TO BE INSTALLED IN CONDUIT PER DIVISION 25.
ALL ROOFTOP EQUIPMENT SHALL BE CONFINED TO THE FLAT ROOF WELL.
30.
31.
32.
33.
1. ALL DUCT OPENINGS AND OTHER AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE
PROTECTED DURING STORAGE ON THE CONSTRUCTION SITE UNTIL FINAL START-UP WITH TAPE,
PLASTIC, SHEET METAL, OR OTHER ACCEPTABLE METHODS TO REDUCE THE AMOUNT OF DUST
AND DEBRIS WHICH MAY COLLECT IN THE SYSTEM PER CALGREEN SECTION 5.504.3.
2. PROVIDE FILTERS WITH A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF AT LEAST 13 FOR
OUTSIDE AND RETURN AIR IN REGULARLY OCCUPIED AREAS OF MECHANICALLY VENTILATED
BUILDINGS PER CALGREEN SECTION 5.504.5.3.
3. HVAC, REFRIGERATION, AND FIRE SUPPRESSION EQUIPMENT SHALL NOT CONTAIN CFC’S OR
HALON PER CALGREEN 5.508.1.
4. ADHESIVES, SEALANTS, AND CAULKS USED ON THE PROJECT SHALL MEET THE REQUIREMENTS
OF CALGREEN SECTION 4.504.2.1.11.
5. PERMANENT HVAC SYSTEMS SHALL ONLY BE USED DURING CONSTRUCTION IF NECESSARY, TO
CONDITION THE BUILDING WITHIN THE REQUIRED TEMPERATURE RANGE FOR MATERIAL AND
EQUIPMENT INSTALLATION. IF THE HVAC SYSTEM IS USED DURING CONSTRUCTION, USE RETURN
AIR FILTERS WITH A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 13, BASED ON ASHRAE
52.1-1992. REPLACE ALL FILTERS IMMEDIATELY PRIOR TO OCCUPANCY PER CALGREEN SECTION
5.504.1.3.
• REUSE OF EXISTING ROOFTOP MECHANICAL UNIT. PROVIDE NEW DUCTING AND ROUTING.
INTERIOR SPACES TO BE REBALANCED FOR PROPER AIR CHANGES.
• INSTALLATION OF VENTED HOOD CANOPY IN KITCHEN AREA. PROVIDE NEW MAKE UP AIR AND
UPBLAST VENTING AIR.
• PROVIDE AIR CURTAIN, DUCTING, AND CONTROLS IN COMPLIANCE WITH LOCAL ENVIRONMENTAL
HEALTH REQUIREMENTS.
• COORDINATION WITH PLUMBING AND ELECTRICAL EQUIPMENT IN PLENUM SPACE.
1. ALL TYPE I AND TYPE II KITCHEN EXHAUST HOOD SYSTEMS AND ASSOCIATED MAKE-UP AIR
UNITS SHALL BE ELECTRICALLY INTERLOCKED SUCH THAT THE EXHAUST FAN AND MAKE-UP
AIR SYSTEM OPERATE SIMULTANEOUSLY. THE EXHAUST HOOD FAN AND THE MAKE-UP AIR UNIT
SHALL BE CONNECTED THROUGH A HARDWIRED ELECTRICAL INTERLOCK OR APPROVED
CONTROL SYSTEM THAT ENSURES THE MAKE-UP AIR SYSTEM AUTOMATICALLY ACTIVATES
WHENEVER THE EXHAUST FAN IS ENERGIZED AND SHUTS DOWN WHENEVER THE EXHAUST
FAN IS DE-ENERGIZED.
2. THE INTERLOCK SHALL PREVENT OPERATION OF THE EXHAUST HOOD WITHOUT THE MAKE-UP
AIR SYSTEM FUNCTIONING AND SHALL ENSURE COORDINATED START-UP AND SHUT-DOWN OF
BOTH SYSTEMS. INTERLOCKING CONTROLS SHALL BE HARDWIRED AND PERMANENTLY
INSTALLED, AND SHALL NOT RELY ON MANUAL SWITCHING ALONE.
3. SYSTEM OPERATION SHALL BE VERIFIED DURING FINAL INSPECTION AND COMMISSIONING TO
CONFIRM THAT ACTIVATION OF THE EXHAUST HOOD FAN RESULTS IN SIMULTANEOUS
OPERATION OF THE MAKE-UP AIR UNIT.
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATE OF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
3/
9
/
2
0
2
6
4
:
2
3
:
0
0
P
M
M-001
MECHANICAL COVER
SHEET
2510
Au
t
h
o
r
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
D HEALTH SUB 4 03/06/2026
2 PLAN RESUBMITTAL 03/09/2026
AIR CONDITION WIRING DIAGRAM
DUCT WORK LEGENDMECH. ABBREVIATIONS PIPING LEGEND VALVE LEGEND
MECH. SYMBOL LEGEND
MECH. GENERAL NOTES
CALGREEN GENERAL NOTESMECHANICAL SCOPE OF WORK HOOD WIRING NOTES
SHEET # SHEET NAME
3 - MECHANICAL
M-001 MECHANICAL COVER SHEET
M-200 MECHANICAL PLANS
M-500 MECHANICAL DETAILS
M-700 MECHANICAL CUTSHEETS
M-701 MECHANICAL CUTSHEETS
M-702 WALK-IN REFRIGERATOR
M-800 TITLE 24 COMPLIANCE
TOTAL: 7
2
S1.5
S1.5
3 4
400 CFM
500
CFM
110 CFM
100
CFM
(E) MECH.
UNIT
16
'
-
0
"
FOR DUCTING
TURNS, REFER
TO DETAIL /5 M-500
FOR DIFFUSER
MOUNTING,
REFER TO
DETAIL /1 M-500
HOOD MUST COMPLY
WITH SMOKE DETECTOR
REQUIREMENTS, REFER
TO DETAIL /12 M-500
M-702
1
11
M-500
400 CFM
(E) 4-TON UNIT ON
ROOFTOP - CONTRACTOR
TO CONFIRM MAKE AND
MODEL IN FIELD
EF
4
.
.
..
.
.
..
.
.
..
.
.
..
MAKE-UP AIR SUPPLY,
SEE CU
2/6 M-500
250 CFM
6
M-200
543 SF
OPEN
DINING
503 SF
COOK
PREP
53 SF
RESTROOM
37 SF
STORAGE
.
.
400 CFM
400 CFM
.
.
16
"
Ø
D
U
C
T
16
"
Ø
D
U
C
T
1
6
"
Ø
D
U
C
T
16
"
Ø
D
U
C
T
12" ØDUCT
12" ØDUCT
PLENUM ABOVE
KITCHEN CEILING
AC
5
12" ØDUCT
12" ØDUCT
RTU
1
T1
3
.
.
.
.
500
CFM
500
CFM
500
CFM
.
.
..
..
METAL BESTOS TYPE
"B" WITH DOUBLE WALL
NOTE:
DO NOT CUT STEEL TEES INTO ROOF WHEN INSTALLING FLUE,
MAX. SIZE OPENING THRU ROOF = 4 1/2"Ø
FOR ROOF CONSTRUCTION.
SEE ARCH. DRAWINGS FOR
DETAIL
4" FLUE VENT
5/8" TYPE "X" GYPSUM
WALL BOARD, TYP.
ROOF FLASHING JACK
STORM COLLAR
METAL BESTOS
FLUE CAP
ROOF
CL
2'
-
0
"
M
I
N
.
ROOF PENETRATION
(STEEL PIPE, TUBE OR SIM.
CAULK WITH
ELASTOMERIC SEALANT
DRAW BAND WITH
NEOPRENE GASKET
WATERTIGHT
UMBRELLA
EXISTING ROOFING
FLANGE SET IN MASTIC
OVER ROOFING PRIME
FLANGE BEFORE STRIPPING
FINISHED ROOF DECK
PROVIDE VENT CAP
FOR VENT THRU ROOF
2"
MI
N
.
3"
MI
N
.
EQ
EQ
.
EQ
E
Q
.
2"
MI
N
.
3"
MI
N
.
2"MIN.
1-3/8"MIN.
30º-45º
48" MAX.
3"
MIN.
EQ
EQ
2x2x1/4
PLATE WASHER
1/2"Ø ASTM A307
BOLT OR ASTM A36
THREADED ROD,
SNUG TIGHT TYP.
MASON SBC-1
SEISMIC
CABLE BRACKET
1/2"Ø ASTM A307 BOLT OR
ASTM A36 THREADED ROD,
WITH 2x2x1/4 PLATE WASHER
ON BACK SIDE OF 4x6
SIMPSON A34 EA.
SIDE EA. END
(E) ROOF
JOIST (V.I.F)
4x6
BLOCKING
(E) ROOF
JOIST (V.I.F)
CASE A CASE B
CASE D
L3x3x1/2 x 0'-6"
(2) 5/8"∅THRU
BOLT
HANGER ROD USE
MIN. 3/8" ∅
THREADED ROD,
DBL. JOIST
L3x3x3/8 x 0'-6"
(2) 1/2"∅THRU
BOLT W / 3" MIN.
SPACING
(E) ROOF
JOIST / 4X
BLKG.STRAP
SIMP. (2)
1/4x1-1/2 SDS
ROOF JOIST /
4X BLKG.
HANGER ROD
USE MIN. 3/8" ∅
THREADED ROD
CASE C
4X BLKG. W /
HU HANGER
STRAP
SIMP. (2)
1/4x1-1/2 SDS
CASE ECASE D
A. EXHAUST HOOD SIZE ------------------
B. FORMULA TYPE "COMMERCIAL KITCHEN"------------------
C. TOTAL CFM (WIDTH X Q)------------------
D. EXH. DUCT SIZE (S.F.)------------------
E. AIR VELOCITY (C/D)------------------
F. FILTER PIECES (SIZE 20)------------------
G. EACH FILTER CFM (C/F)------------------
AVERAGE CFM PER LINEAR FOOT ------------------
UL 762 -CONTINUOUS DUTY RATING
MAX. TEMPERATURE RATING: 700 DEG. F
HOOD -16' -0" FT TYPE-1 EXHAUST HOOD SYSTEM
SUPPLY UNIT W/24" MIXED FLOW
DIRECT DRIVE FAN, SIZE #3 HOUSING
SP & HP FAN ---------------------
APPROX WEIGHT---------------------------
EA UNIT SHALL DELIVER ---------------------
(M/A100% AIR DELIVERY REQUIRED TO EXH SYSTEM)
ELECTRICAL:
DESIGN TOLERANCE OUTPUT:
MAX OUTPUT:
MAKE UP AIR SYSTEM -UPBLAST
NOTES
4' X 16' (64 SQ FT)
Q = 300 CFM / LINEAR FT
4,800 CFM
24"X24"= 4 SQ FT
6,400 / 4 = 1600 FPM
1 PIECES
4,800 CFM
300 CFM
0.25 HP & 1.5 HP
506.5 LBS
5,060 CFM
230/460V -3Ø 60HZ UNIT
80% MIN. EXHAUST AIR
5,060 CFM / 4,800 CFM = 105 %
EQ #QTY EQUIPMENT
NAME
EXISTING /
NEW
MAKE/
MODEL WATTS NOTES
1
2
3
4
5
1
1
1
1
1
4 TON RTU
CENTRIFUGAL
UPBLAST SYSTEM
RESTROOM
EXHAUST FAN
EXISTING
NEW
NEW WHISPERFIT DC,
PICK-A-FLOW
ENERGY STAR
QUIET EXHAUST
FAN
14W
AIR CURTAIN NEW BREEZE9 48"
AC-1048-12-BK 1,648 MAX CFM. 530 W
TYPE 1 VENTED
HOOD NEW
16' - 0" FT
CAPTIVEAIRE TYPE-1
WALL CANOPY
1.5 HP1200 W
CAPTIVEAIRE
DIRECT UPBLAST
EXHAUST FAN
WEATHEREXPERT
SINGLE PACK
ROOFTOP UNIT
1200 W
(E)
1.5 HP
-
6 1 MAKE UP AIR NEW
CAPTIVEAIRE
INLINE3-24D
SUPPLY UNIT
5,060 MAX CFM. 3,730 W
SL
O
P
E
SL
O
P
E
SLOPE SLOPE
LEAD FLASHING
OVERFLOW
DRAIN
ROOF DRAIN
SET DRAIN ELEV. 2" BELOW
SUMP PERIMETER
CL
CLCL
0' - 6" 2' - 0" 2' - 0"
0'
-
6
"
2
'
-
0
"
2
'
-
0
"
0
'
-
4
"
4' - 0"
SET DRAIN ELEV. 2"
BELOW SUMP PERIMETER
DRAIN STRAINER
TAPERED
INSULATION
ROOF DECK
MEMBRANE FIELD PLIES,
METAL FLASHING AND
STRIPPING PLIES ALL
EXTEND UNDER
CLAMPING RING
MULTIPLE-PLY
MODIFIED BITUMEN
ROOF MEMBRANE
MULTIPLE-PLY
MEMBRANE FLASHING
30" SQUARE MIN., 2 1/2 LB.
TO 4 LB. LEAD OR 16 OZ.
COPPER FLASHING SET
ON FINISH ROOF IN
FLASHING CEMENT,
PRIME TOP SURFACE
BEFORE STRIPPING
DECK CLAMP
RIGID INSULATION
COVERBOARD
INSULATION
CL
MIN.
0' - 0 23/32"
CL
SLOPE SLOPE
SLOPE
0' - 1 29/32"
CL
OVERFLOW
NOTES:
1. MINIMUM 30" SQUARE, 4 LB. LEAD OR 16 OZ. SOFT COPPER FLASHING.
PRIME TOP SURFACE BEFORE STRIPPING.
2. STRIPPING FELTS-EXTEND 4" AND 6" BEYOND EDGE OF FLASHING
SHEET, BUT NOT BEYOND EDGE OF SUMP.
3. AT OVERFLOW DRAIN CONDITIONS SET ROOF DRAIN 2" UP SLOPE OF
ROOF OR PROVIDE A WATERGUARD 2" HIGHER THAN ADJACENT ROOF.
OVERFLOW DRAIN LEADER SHALL BE SEPERATE FROM ROOF DRAIN
LEADER.
4"
FULL DOME STRAINER
AT ROOF AND
OVERFLOW DRAIN
CLAMPING RING
LEAD FLASHING
MULTI-PLY MEMBRANE
BASE FLASHING
MEMBRANE ROOFING
EXISTING ROOF
FIRST FLOOR
0' -0"
ROOF
10' -0"
CEILING
9' -4"
TANKLESS WATER
HEATER
(E) ROOF VENT
PENETRATION PER
DETAIL
AND
NOTE:
ROOF PENETRATIONS TO EXTEND
ABOVE THE CEILING PLANE, TYP.
/3 M-200
/4 M-200
(E) ROOF
OVERFLOW DRAIN
PER DETAIL /2 M-200
(E) ROOFTOP
UNIT
(E) MECH. CURB
RTU
1
OPEN DINING
ROOM NAME VOLUME
CUBIC FEET AIR SUPPLYAIR CHANGE
PER HOUR PRESSUREAIR RETURN
HALLWAY
RESTROOM
KITCHEN
6,720 CF 7 ACH 785 CFM BALANCE
5 ACH
1 ACH
15 ACH
STORAGE 2 ACH
746 CF
560 CF
4,665 CF
373 CF
BALANCE
NEGATIVE
POSITIVE
BALANCE
62 CFM
-
1,165 CFM
25 CFM
785 CFM
62 CFM
110 CFM
1,000 CFM
25 CFM
CMC 609.1 AIR-MOVING SYSTEMS AND SMOKE DETECTORS.
AIR-MOVING SYSTEMS SUPPLYING AIR IN EXCESS OF 2000 CUBIC FEET PER MINUTE (FT3/MIN) (0.9439 M3/S)
TO ENCLOSED SPACES WITHIN BUILDINGS SHALL BE EQUIPPED WITH AN AUTOMATIC SHUTOFF.
AUTOMATIC SHUTOFF SHALL BE ACCOMPLISHED BY INTERRUPTING THE POWER SOURCE OF THE AIR-
MOVING EQUIPMENT UPON DETECTION OF SMOKE IN THE MAIN SUPPLY-AIR DUCT SERVED BY SUCH
EQUIPMENT. DUCT SMOKE DETECTORS SHALL COMPLY WITH UL 268A, SHALL BE LABELED BY AN
APPROVED AGENCY, APPROVED AND LISTED BY CALIFORNIA STATE FIRE MARSHAL, AND SHALL BE
INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION INSTRUCTIONS. SUCH DEVICES
SHALL BE COMPATIBLE WITH THE OPERATING VELOCITIES, PRESSURES, TEMPERATURES, AND
HUMIDITIES OF THE SYSTEM. WHERE FIRE-DETECTION OR ALARM SYSTEMS ARE PROVIDED FOR THE
BUILDING, THE SMOKE DETECTORS SHALL BE SUPERVISED BY SUCH SYSTEMS IN AN APPROVED MANNER,
AND INSTALLED IN ACCORDANCE WITH NFPA 72 AND THE CALIFORNIA BUILDING AND FIRE CODES.
CMC 401.2 FILTERS
IN MECHANICALLY VENTILATED BUILDINGS, PROVIDE REGULARLY OCCUPIED AREAS OF THE BUILDING
WITH AIR FILTRATION MEDIA FOR OUTSIDE AND RETURN AIR THAT PROVIDES AT LEAST A MINIMUM
EFFICIENCY REPORTING VALUE (MERV) OF 13. MERV 13 FILTERS SHALL BE INSTALLED PRIOR TO
OCCUPANCY, AND RECOMMENDATIONS FOR MAINTENANCE WITH FILTERS OF THE SAME VALUE SHALL
BE INCLUDED IN THE OPERATION AND MAINTENANCE MANUAL IN COMPLIANCE WITH CHAPTER 5,
DIVISION 5.5. OF THE CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN).
CMC 510.5.3
PENETRATIONS SHALL BE PERMITTED TO BE SEALED BY OTHER LISTED DEVICES THAT ARE TESTED TO
BE GREASETIGHT AND ARE EVALUATED UNDER THE SAME CONDITIONS OF FIRE SEVERITY AS THE HOOD
OR ENCLOSURE OF LISTED GREASE EXTRACTORS AND WHOSE PRESENCE DOES NOT DETRACT FROM
THE HOOD’S OR DUCT’S STRUCTURAL INTEGRITY.[NFPA 96:7.5.2.3]
NOTE*
CITY INSPECTOR TO PERFORM AIR BALANCE TEST AND AIR LEAKAGE TEST FOR FINAL INSPECTION
FIRE CONTROL PANEL HEAT DETECTOR
CONTROL
MODULE
INSTALL
PANEL
OUTDOOR
UNIT
INDOOR
VENT
DB
(E) ROOF WELL
(E) 4 TON RTU -
NOT IN SCOPE
(E) VENT STACK
(E) FLUE VENT
(E) 4 TON RTU. TO
REMAIN, PROTECT
IN PLACE
18' - 10"
(N) (2) TANKLESS
WATER HEATERS -
SEE PLUMBING
11
'
-
5
"
(E) ACCESS
LADDER TO
REMAIN
(E) ROOF DRAIN
(E) OVERFLOW
DRAIN
8
RTU
1
MUA
1
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATE OF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
3/
9
/
2
0
2
6
4
:
2
3
:
0
2
P
M
M-200
MECHANICAL PLANS
2510
Au
t
h
o
r
12" = 1'-0"WH FLUE VENT DETAIL 4 12" = 1'-0"VENT THRU ROOF DETAIL 3
1/4" = 1'-0"MECHANICAL DUCTING PLAN 1
12" = 1'-0"TYP. HANGER + BRACE @WOOD STRUCT.5
TYPE I - HOOD CALCULATION
MECHANICAL EQUIPMENT SCHEDULE
1 1/2" =
1'-0"ROOF DRAIN SUMP W/ ADJACENT OVERFLOW 2
1/4" = 1'-0"MECHANICAL SECTION 6
AIR CHANGE LEGEND
AUTOMATIC SHUTOFF NOTES
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
C HEALTH SUB 3 02/25/2026
2 PLAN RESUBMITTAL 03/09/2026
1/4" = 1'-0"MECH. ROOF PLAN 7
1" 26" GA. GL. STRAP
TO SUPPORT JOIST
DUCT WRAP, SEE ATTACHED
CUT SHEETS ON M-104
FIRE-RESISTANT
WALL ASSEMBLY
SEE FLOOR PLAN
FOR WALL TYPE
FINISHED FLOOR PER
FLOOR FINISH PLAN
GREASE -FILTER
BAFFLE TYPE, NFPA 96
FINISHED CEILING
MECH. AND FIRE APPROVAL
SHALL BE REQUIRED ON FIRE
PROTECTION SYSTEM FOR
EXHAUST HOOD AND DUCT
PER CMC 513
HOOD LESS THAN 12" FROM
CEILING MUST BE FLASHED SOLID
SUPPORT WITH 25GA. MTL STUD
@24" O.C. BRACING @48" O.C.
OVERHANG
6" MIN.
4'
-
0
"
M
A
X
.
3" MIN.
FILTER COVER
KITCHEN
EQUIPMENT
MERV-13 MINIMUM FILTER
REQUIREMENTS AT INTAKE
AND EXHAUST PER
CALGREEN REQUIREMENTS
“TYPE-1 HOOD REQUIRES AIR BALANCE
REPORT FOR FINAL INSPECTION.”
510.5.3.1
DUCT LEAKAGE TEST. PRIOR TO THE
USE OF OR CONCEALMENT OF ANY
PORTION OF A GREASE DUCT SYSTEM,
A LEAKAGE TEST SHALL BE
PERFORMED TO DETERMINE THAT ALL
WELDED JOINTS AND SEAMS ARE
LIQUID TIGHT. [NFPA 96:7.5.2.1.2]
6"
C
A
S
T
E
R
S
CONDENSATION
DRAIN, SEE DETAIL /8 M-500
DETECTOR SYSTEM
DUCTING CONNECTION
TO ROOF WELL
DIA. +2"
FLEX DUCT
ATTACH TO
DIFFUSER &
SEISMIC CLIP
T-BAR TYPICAL
FOR 4, ONE PER SIDE
NOTE:
T-BAR MOUNTED
CEILING DIFFUSER/REGISTER
WITH SEISMIC RESTRAINT TABS.
MINIMUM HEIGHT
CEILING DIFFUSER BOX
WITH 1" LINING
COLLAR
MIN. 2"
6"
VOLUME
DAMPER
CEILING
EQUALIZING
GRID
INSULATED FLEX
SEE PLAN FOR SIZE *
12 GA. SEISMIC WIRE. 2
PER DIFFUSER @
DIAGONAL CORNERS
1. RETURN AIR REGISTERS, EXHAUST AIR GRILLES ETC, SIMILAR.
2. FLEXIBLE DUCT & INSULATION SHALL HAVE A FLAME SPREAD OF NOT MORE THAN
25 AND A SMOKE DENSITY NOT EXCEEDING 50 (C.M.C. SECTION 605.0)
12 GA. WIRE TO
ROOF CAP, LAG TO ROOF
CURB W/ (4) 3/8"Ø LAG
SCREWS MIN. 2"
EMBEDMENT
8" MAX HEIGHT @HIGH
POINT OF ROOF
EXHAUST FAN
EXHAUST FAN GRILLE
EXHAUST DUCT,
SEE PLAN FOR
SIZE
CEILING
PLENUM SPACE
(E) ROOF
FACTORY ROOF CAP & CURB
W/INTEGRAL BIRDSCREEN
SEE DETAIL
5'-0" MAX. LENGTH.2'-0" MAX.
CEILING DIFFUSER
NOTES:
VOLUME DAMPER
SUPPORT FLEX DUCT WITH
BAND WITH HEMMED EDGES
1-1/2" WIDE, 20 GAGE, SHEET METAL
INSULATED FLEX DUCT, SEE PLAN(S)
4 TIGHT TURNS WITHIN
1-1/2". TYP.
PROVIDE SMOOTH RADIUS CONNECTION,
PROPERLY SUPPORT FLEX DUCT FOR
SMOOTH AIR FLOW TO DIFFUSER. FLEX
DUCT SHALL NOT EXCEED 5'-0" IN LENGTH
DIFFUSER CAN BY CEILING DIFFUSER
MANUFACTURER
CEILING WHERE
OCCURS
CEILING DIFFUSER WITH FILLER PANEL.
SEE PLANS FOR SIZES. POSITIVELY
ATTACH DIFFUSE PANEL TO CEILING
SUSPENSION MAIN RUNNERS WITH
MINIMUM (4) SMS SCREWS.
FOR GRILLES WEIGHING LESS THAN
56 LBS. USE 2 SLACK WIRES, AND
FOR GRILLES WEIGHING 56 LBS. OR
HEAVIER USE 4 TAUT WIRES.
1
1
1. RETURN AIR REGISTERS, EXHAUST AIR GRILLES ETC, SIMILAR.
2. FLEXIBLE DUCT & INSULATION SHALL HAVE A FLAME SPREAD OF
NOT MORE THAN 25 AND A SMOKE DENSITY NOT EXCEEDING 50
(C.M.C. SECTION 604.3)
12 GA. SEISMIC CABLE AT
CORNER OF DIFFUSER
STRAP: 2" MIN. x 22 GA
SEISMIC TAB
2"X1"X22GA BENT PLATE
TYP. AT 4 CORNERS.
S/M SCREW. TYP.
MANUAL
3/8"∅MACHINE
BOLT, NUT AND
SPRING WASHER
20"∅
1-1/2"x20 GA.
DUCT SIZE
UP TO 20" DIAMETER SPIRAL ROUND
HANGER SUPPORT MATERIAL MAXIMUM DISTANCE
1-1/2" WIDE 22 GA. GI STRAP 8'-0" O.C.
18" MAX ONE SIDE / 12" MAX OTHER SIDE 1" WIDE 22 GA. GI STRAP 8'-0" O.C.
SECTION STRAP
TYPICAL.
MAX.
48" MAX ONE SIDE / 24" MAX OTHER SIDE 1" WIDE 20 GA. GI STRAP 8'-0" O.C.
TYPICAL.
FOR ATTACHMENT TO BUILDING STRUCTURE,
SEE DETAIL 8/ THIS SHEET.
LONGITUDINAL BRACE AT 30'-0" O.C. MAX. SPACING.
ALTERNATE SIDE EVERY SUPPORT.
1-1/2"X1-1/2"X 20 GA. GALV. S/M.
TRANSVERSE BRACE 16'-0" O.C. MAX. SPACING.
ALTERNATE SIDE EVERY SUPPORT.
1-1/2"X1-1/2"X 20 GA. GALV. S/M.
1
1 1
1
1
1
#10 X 3/4" SELF TAPPING
S.M.S.
EQUALLY SPACED 12" O.C.
MAX. MINIMUM 2 PER SIDE.
(TYPICAL)
RIGID ACOUSTIC
DUCTWORK
FLEXIBLE DUCTWORK
CEILING DIFFUSER
OPTIONAL IN-WALL
MOUNTING BOX
MODEL EDB-WALL
WALL UNIT
MODULAR
CONNECTOR
BATTERY POWERED HAND
HELD CONTROLLER WITH LCD
POSITION INDICATOR.
PLENUM RATED FIVE
(5) CONDUCTOR WIRE
MODEL EBD-301
RECESSED
CEILING UNIT.
ELECTRONIC BALANCING DAMPER WITH
POSITION INDICATOR.
EBD FOR ROUND APPLICATION.
EBDR FOR RECTANGULAR APPLICATION.
PLUG LOCATIONS:
1. WHERE THERE ARE CEILING ACCESS PANELS FOR OTHER
PURPOSES, PLUG RECEPTACLES MAY BE LOCATED ABOVE CEILING
2. AT VAV TERMINAL THAT SERVES DAMPERS LABEL EACH
RECEPTACLE TO MATCH DAMPER
GYP BOARD CEILING
FACTORY HANGER
BAR AT FRONT AND
BACK.
CEILING JOIST
PER RCP, TYP.
FLAT HEAD TEK
SCREW #12 X 1". 2
PER BRACKET
EXHAUST FAN
MAX OPER. WEIGHT
20 LBS
SWITCH, OUTLET,
CONTROL BOX
TOP OF THERMOSTAT,
24" MAX.
34
"
M
A
X
.
48
"
M
A
X
.
OUTLET OR SWITCH BOX
BOTTOM OF
15" MIN.
F.F.L.
46
"
M
A
X
.
S
I
D
E
A
P
P
R
O
A
C
H
44
"
M
A
X
.
F
R
O
N
T
A
P
P
R
O
A
C
H
SWITCH, OUTLET,
CONTROL BOX
TOP OF THERMOSTAT,
FORWARD OR FRONT APPROACH FOR DEVICES
MOUNTED ABOVE COUNTERS ASSUMES THAT DIRECTLY
BELOW THE DEVICE, THE COUNTER HAS A 30" MIN.
WIDTH x 27" MIN. HIGH x A DEPTH EQUAL TO THE
SE
E
N
O
T
E
B
E
L
O
W
.
SIDE
APPROACH
27
"
M
I
N
.
COUNTER DEPTH CLEAR OPENING.
LAPPED AND BUTTED
CORNER
ALL TRANSVERSE
EDGES COATED AT
FACTORY OR SHOP
APPLIED
NOMINAL
INSULATION
THICKNESS 1/8" MAX.
AIR FLOW
A FROM CORNERS OF DUCT 4"
DIMENSION 0 - 2500 FPM
VELOCITY
2501 - 6000 FPM
VELOCITY
B FROM TRAVERSE END OF DUCT LINER 3"
C ACROSS WIDTH OF DUCT, ON CENTERS (MIN. 1 PER SIDE)12"
D 18"ALONG LENGTH OF DUCT, ON CENTERS (MIN. 1 PER SIDE)
4"
3"
6"
16"
NOTE:
WHEN VELOCITY EXCEEDS 1750 FPM, INSTALL METAL
NOSING ON EDGES OF DUCT LINER FACING AIR STREAM.
D" Ø
D" Ø
CONICAL
45° LATERAL
FITTING
1
1
TEE
D" Ø2
D" Ø2
D" Ø1
45° LATERAL
D" Ø
D" Ø
3
1
D" Ø2
THIS PORTION FOR
CONTINUING
DUCT RUN
D" Ø3
D" Ø2
RECTANGULAR DUCT
RECTANGULAR DUCT
D"Ø
D"Ø
45° LATERAL
FITTING
X" x Y"
CONICAL OR
STANDARD
BELLMOUTH
FITTING
X" x Y"
D" ØROUND
TRANSITION
ROUND TO
D" Ø
TRANSITION
1
2
D"1
RECTANGULAR
TO ROUND
X" x Y"
1D"
D"Ø
SEE FLOOR PLANS FOR
EXHAUST DUCT RISER
SIZE & CONFIGURATION
RIGID INSULATION
CANT STRIP AND
ROOFING
20 GA. LEVEL ROOF CURB
FACTORY FABRICATED
W/ WELDED EDGES BY MECHANICAL
COUNTER FLASHING MITER CORNER
20 GA. CONT. GALV. SHEET METAL
CONTRACTOR
4"WOOD NAILER
#10 x 1.5" S/S TEK SCREWS
MIN. 3 AT EACH SIDE.
(TOTAL 12 PER UNIT)
3/8" DIA. S/S LAG SCREW W/ 3" MIN.
EMBED TO LEVEL WOOD CURB,
MIN. (3) AT EACH SIDE TYPICAL.
WHEN CALLED OUT ON
FLEX CONNECTION
MECH. FLOOR PLANS
TRANSITION
DAMPER ON DAMPER TRAY.
LIGHTWEIGHT GRAVITY BACKDRAFT
SEE FAN SCHEDULE.
4X SLEEPER. 4" TALL MAX.
4X PERIMETER BLKG W/
A34 @ EA. END TYP.
3/8" DIA. THRU BOLT
(COUNTERSUNK) 3 AT EACH SIDE
TYP.
3"
M
I
N
.
DISCONNECT MOUNTED ON UNIT.
SEE ELEC.
SEE ARCH FOR
ROOF CONSTRUCTION
UNISTRUT
CUSH-A-CLAMP
FRONT VIEW
SIDE VIEW
MASTIC
UNISTRUT
CONDUIT CLAMP
DURABLOK
DURABLOCK
MASTIC
DURABLOCK
GASKET AT
PENETRATION, TYP.
U.L. LISTED SMOKE
DETECTOR
HOUSING
TOTAL ENCLOSED
NEMA 3R
WEATHERPROOF
HOUSING
WIRING
COMPARTMENT
NO. 10 S.S.
SHEETMETAL SCREWS
6" O.C., TYP.
NOTES:
1. SMOKE DETECTOR SHALL
BE STATE FIRE MARSHALL
APPROVED, U.L. LISTED
AND INSTALLED STRICTLY
PER MANUFACTURER'S
PRINTED INSTRUCTIONS
2. MANUFACTURER'S
INSTALLATION
INSTRUCTIONS SHALL BE
MADE AVAILABLE TO THE
INSPECTION AUTHORITIES
3. AIR VELOCITY INSIDE
DUCTWORK SHALL BE
ABOVE THE MINIMUM
VELOCITY AT ALL TIMES
OUTSIDE EXPOSED
DUCT, MI. 18 GA
CONSTRUCTION
RETURN TUBE
REINFORCED
SHEETMETAL PLATE AT
PENETRATION
SUPPLY TUBE
DUCT SUMP 1 1/4"
DRAIN CONNECTION
TEE CONNECTION
W/ PLUG
VENT
INDIRECT DRAIN
NEARBY, FLOOR SINK
AT 2% SLOPE MIN.
MAU
3"
M
I
N
.
3"
M
I
N
.
3" SCHE. 40. PVC
COMBUSTION AIR PIPE
COMBUSTION AIR
INLET W/SCREEN
MASTIC SEAL, TYP.
ROOF
2X6 FRAMED AROUND
OPENING
18 GA ANGLE CLIP
FOLLOW FACTORY
INSTALLATION REQUIREMENT
FOR CLEARANCE OF FLUE
VENT
PIPE CLAMP
3" SCHE. 40. PVC
FLUE 16 GA SHEET
METAL FLASHING
WITH FLASHING
CLAMP BY MECH.
NAILED TO ROOF
FLASHING W/SLEEVE.
SEE ARCH DRAWING
12
"
M
I
N
.
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATE OF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
3/
9
/
2
0
2
6
4
:
2
3
:
0
3
P
M
M-500
MECHANICAL DETAILS
2510
Au
t
h
o
r
12" = 1'-0"INSULATED PIPE AND CONDUIT SUPPORT 4
1/2" = 1'-0"KITCHEN EQUIPMENT SECTION 11
3" = 1'-0"ROOF CONDENSATE DRAIN DETAIL 16
1 1/2" =
1'-0"SMOKE DETECTOR MOUNTING DETAIL 12
1 1/2" =
1'-0"HOOD CONDENSATE DRAIN DETAIL 8
12" = 1'-0"CEILING DIFFUSER MOUNTING 1
12" = 1'-0"CEILING MOUNTED EXHAUST FAN 13
12" = 1'-0"CEILING MOUNT EXHAUST FAN VENT TO ROOF CAP 9
12" = 1'-0"CEILING ROUND DIFFUSER MOUNTING 7
12" = 1'-0"CONTROL DEVICE MOUNTING 10
12" = 1'-0"DUCT HANGER - RECTANGULAR AND ROUND 3 12" = 1'-0"DUCT LINING DETAIL 2
12" = 1'-0"DUCT TRANSITION REQUIREMENTS 5
12" = 1'-0"ELEC BAL. DAMPER FOR INACCESSIBLE CONDITIONS 14
12" = 1'-0"ROOF MOUNTED FAN ON FIELD CURB 6
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 03/09/2026
508.3 CONSTRUCTION OF TYPE I HOODS.
THE HOOD OR THAT PORTION OF A PRIMARY COLLECTION MEANS DESIGNED FOR COLLECTING
COOKING VAPORS AND RESIDUES SHALL BE CONSTRUCTED OF AND BE SUPPORTED BY STEEL NOT
LESS THAN 0.048 OF AN INCH (1.219 MM) (NO. 18 MSG), IN THICKNESS, STAINLESS STEEL NOT LESS
THAN 0.036 OF AN INCH (0.914 MM) (NO. 20 MSG) IN THICKNESS, OR OTHER APPROVED MATERIAL OF
EQUIVALENT STRENGTH AND FIRE AND CORROSION RESISTANCE. [NFPA 96:5.1.1]
508.5 HOOD SIZE.
HOODS SHALL BE SIZED IN ACCORDANCE WITH THE AIRFLOW CAPACITY IN ACCORDANCE WITH
SECTION 508.5.1.1 AND INSTALLED TO PROVIDE FOR THE REMOVAL OF HEAT, AND CAPTURE AND
REMOVAL OF GREASE-LADEN VAPORS IN ACCORDANCE WITH SECTION 511.2.2.
508.5.1 CANOPY SIZE AND LOCATION.
FOR CANOPY TYPE COMMERCIAL COOKING HOODS, THE INSIDE EDGE THEREOF SHALL OVERHANG
OR EXTEND A HORIZONTAL DISTANCE OF NOT LESS THAN 6 INCHES (152 MM) BEYOND THE EDGE OF
THE COOKING SURFACE ON OPEN SIDES, AND THE VERTICAL DISTANCE BETWEEN THE LIP OF THE
HOOD AND THE COOKING SURFACE SHALL NOT EXCEED 4 FEET (1219 MM).
EXCEPTION: LISTED EXHAUST HOODS ARE TO BE INSTALLED IN ACCORDANCE WITH THE TERMS OF
THEIR LISTINGS AND THE MAN UFACTURER’S INSTALLATION INSTRUCTIONS.
508.5.1.1 CAPACITY OF HOODS.
CANOPY-TYPE COMMERCIAL COOKING HOODS SHALL EXHAUST THROUGH THE HOOD WITH A
QUANTITY OF AIR NOT LESS THAN DETERMINED BY THE APPLICATION IN ACCORDANCE WITH SECTION
508.5.1.2 THROUGH SECTION 508.5.1.5. THE EXHAUST QUANTITY SHALL BE THE NET EXHAUST FROM
THE HOOD DETERMINED IN ACCORDANCE WITH EQUATION 508.5.1.1. THE DUTY LEVEL FOR THE HOOD
SHALL BE THE DUTY LEVEL OF THE APPLIANCE THAT HAS THE HIGHEST (HEAVIEST) DUTY LEVEL OF
APPLIANCES INSTALLED UNDERNEATH THE HOOD. EXCEPTION: LISTED EXHAUST HOODS INSTALLED
IN ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION INSTRUCTIONS.
OVEN FLUE DUCT
OVEN FLUE
DUCT COLLAR
OVEN
SPACE
EXHAUST HOOD
FIGURE 508.3.3
TYPICAL SECTION OF
EYEBROW-TYPE HOOD
[NFPA 96: FIGURE 5.1.8.1]
VENTED HOOD NOTES
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATE OF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
3/
9
/
2
0
2
6
4
:
2
3
:
0
4
P
M
M-700
MECHANICAL CUTSHEETS
2510
Au
t
h
o
r
CAPTIVEAIRE ND-2 16' -0" FT TYPE-1 EXHAUST HOOD WALL CANOPY
CAPTIVEAIRE INLINE 3 -MAKEUP AIR SYSTEM -A3-24D
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
1 PLAN RESUBMITTAL 01/16/2026
B HEALTH SUB 2 02/04/2026
C HEALTH SUB 3 02/25/2026
D HEALTH SUB 4 03/06/2026
2 PLAN RESUBMITTAL 03/09/2026
1
CAPTIVEAIRE EXHAUST DIRECT UPBLAST SYSTEM -DU-HFA
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATE OF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
3/
9
/
2
0
2
6
4
:
2
3
:
0
5
P
M
M-701
MECHANICAL CUTSHEETS
2510
Au
t
h
o
r
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
1 PLAN RESUBMITTAL 01/16/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 03/09/2026
1
CEILING EXHAUST FAN
60"
72
"
52"
67
"
30
"
10
"
DRILL HOLE IN SIDE OF
W - IN BOX AND PROVIDE
SILICONE SEAL AROUND
PIPE PENETRATION
PROVIDE TRAP AT
BOTTOM OF RISER
AND DISCHARGE INTO
FLOOR SINK WITH AIR
GAP OF TWICE PIPE
DIAMETER.
FINISHED
FLOOR PER
FINISH
SCHEDULE
SEE PLUMBING PLANS
FOR INDIRECT DRAIN
LINE TO FLOOR SINK
PROVIDE 1" ELASTOMERIC INSULATION
OVER HEAT TRACING ON CONDENSATE
LINE, IF/WHEN FREEZER BOX ONLY.
(ELECTRIC HEATING CABLE BY OTHERS)
CONNECTION TO
COIL AS REQUIRED
DX COIL
INSTALL PIPING AS HIGH AS THE SPACE AVAILABLE ALLOWS. ANCHOR TO
WALL OF BOX WITH SUPPORTS AT MAXIMUM SIX FOOT CENTERS. USE
TYPE "M" HARD COPPER TUBE AND FITTINGS WITH LEAD-FREE SOLDER
JOINTS. SLOPE HORIZONTAL PIPE AT MINIMUM 2%. REFER TO CODE OF
LOCAL JURISDICTION FOR INDIRECT DRAIN LINE REQUIREMENTS
C/OC/O
COORDINATE
ROUTING OF DRAIN
WITH SHELVING
PLACEMENT OF
THE WALK-IN BOX
TRAP WITH VENT
NO INSULATION
ON PIPE RISER
WALK IN
COOLER
3/4"
WALK IN COOLER SPECIFICATIONS
FLOOR MOUNTING:
ELEVATION CHANGE:
FLOOR FINISH:
WALL FINISH:
CEILING FINISH:
SURFACE MOUNTED
INTERIOR 4" RAMP
22 GA STAINLESS STEEL
26 GA ZINC-ALUMINUM COATED STEEL
26 GA ZINC-ALUMINUM COATED STEEL
1" = 1'-0"WALK IN REF BOX CONDENSER 2
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATE OF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
3/
9
/
2
0
2
6
4
:
2
3
:
0
5
P
M
M-702
WALK-IN REFRIGERATOR
2510
Au
t
h
o
r
3/4" = 1'-0"ENLARGED WALK-IN FLOOR PLAN 1
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
1 PLAN RESUBMITTAL 01/16/2026
B HEALTH SUB 2 02/04/2026
C HEALTH SUB 3 02/25/2026
2 PLAN RESUBMITTAL 03/09/2026
WALK IN COOLER FINISHES 1
1" = 1'-0"WALK IN REF CEILING PANEL 3
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATE OF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
3/
9
/
2
0
2
6
4
:
2
3
:
0
6
P
M
M-800
TITLE 24 COMPLIANCE
2510
Au
t
h
o
r
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 03/09/2026
128 W MacArthur BlvdSanta Ana, CA 92707
SHEET INDEX
THE NOODLE LOFT
128 W MACARTHUR BLVD
SANTA ANA, CA 92707
• DEMOLITION OF THE EXISTING NON-BEARING WALLS OF THE PREVIOUS TENANT SPACE.
• NEW ELECTRICAL WIRING FOR COMMERCIAL KITCHEN AND OPEN DINING SPACES. INSTALLATION
WORK TO BE COMPLETED BY A LICENSED ELECTRICIAN. NEW ROUTING AND DUCTING TO BE
CONNECTED TO THE EXISTING MECHANICAL UNIT. NEW PLUMBING FIXTURES AND
UNDERGROUND PIPING TO BE INSTALLED.
• UPGRADE TO RESTROOM TO MEET ACCESSIBILITY CODE COMPLIANCE.
• INSTALLATION OF NEW VENTED HOOD AND MAKE-UP AIR SYSTEM.
A. P. N.:
ADDRESS:
ZONING:
TYPE OF CONSTRUCTION:
OCCUPANCY:
BUILDING AREA S.F.
PROPOSED S.F.:
SPRINKLERED:
SCOPE OF WORK
PROJECT INFORMATION
K1
K1
ROOM
NAME
101
A2.32
1
1
1
1 ELEVATION
ALIGN
DIMENSION CENTERLINE
DIMENSION
REVISION CLOUD
KEY NOTE
COLUMN GRID LINE
ROOM REFERENCE
SECTION
REFERENCE
ELEVATION
REFERENCE
DETAIL OR ENLARGED PLAN
DATUM
7' - 6"
7' - 6"
CL
SHEET NUMBER
VIEW NUMBER
VIEW NAME
DRAWING SCALE
VIEW NUMBER
NORTH ARROW
(PROJECT NORTH U.O.N.)
101
LEGEND AND SYMBOLS
VICINITY MAP
APPLICABLE CODE
DEFERRED SUBMITTAL
3' - 9"3' - 9"
AUTHORITY HAVING JURISDICTION : CITY OF SANTA ANA
ALL WORK SHALL COMPLY WITH THE FOLLOWING CODES:
• 2022 CALIFORNIA BUILDING CODE
• ORANGE COUNTY ENVIRONMENTAL HEALTH DEPARTMENT
• 2022 CALIFORNIA ELECTRICAL CODE
• 2022 CALIFORNIA PLUMBING CODE
• 2022 CALIFORNIA MECHANICAL CODE
• 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE
• 2022 CALIFORNIA ENERGY CODE
• 2022 CALIFORNIA FIRE CODE
SITE FACILITY MAP
PROJECT TEAM
KEY NOTE
A-?
?
DETAIL SECTION
REFERENCEA-?
?
A-?
1
410-041-51
128 W MACARTHUR BLVD, SANTA ANA, CA 92707
C4 - COMMERCIAL PLANNED SHOPPING CENTER
TYPE V-B
GROUP B
1,240 SQUARE FOOT
N/A
NO
PROJECT SITE
• ANSUL FIRE SUPPRESSION SYSTEM
OWNER: LEGACY THAI GROUP
CONTACT: SUKITTI KEERATIPRAPA
E-MAIL: LEGACYTHAIGROUP@GMAIL.COM
TEL: (949) 836-1777
ARCHITECT OF RECORD : SANDPIPER ARCHITECTURE
CONTACT: SAMUEL PIPER
E-MAIL: SANDPIPERARCHITECT@GMAIL.COM
TEL: (707) 815-6742
ENGINEER OF RECORD: ERIC CHEN
CONTACT: ERIC CHEN
E-MAIL: HSINGYUERIC@GMAIL.COM
TEL: (626) 423-8463
55
73
405
S
B
R
I
S
T
O
L
S
T
MACARTHUR BLVD
MA
I
N
S
T
BE
A
R
S
T
PROJECT LOCATION
BAKER ST JOHN
WAYNE
AIRPORT
RED HILL AVE
E DYER RD
A.F.F.ABOVE FINISHED FLOOR
A.G.ACCESSORY GROUP
A.D.ACCESS DOOR
ACOUS ACOUSTICAL
ACT.ACOUSTICAL TILE
ADD ADDENDUM
ADJ ADJACENT
A.C.AIR CONDITION
ALT ALTERNATE
ALUM ALUMINUM
A.B.ANCHOR BOLT
APPROX APPROXIMATE
ARCH ARCHITECTURAL
AD AREA DRAIN
AUTO AUTOMATIC
ASL ABOVE SEA LEVEL
B.E.J.BRICK EXPANSION JOINT
BSMT BASEMENT
B.T.BATH TUB
BM BEAM
BRG BEARING
B.M.BENCH MARK
BET BETWEEN
BIT BITUMINOUS
BLK BLOCK
BLKG BLOCKING
BD BOARD
BS BOTH SIDES
BOT BOTTOM
BRK BRICK
B.C.BRICK COURSE
BLDG BUILDING
BUR BUILT-UP ROOFING
B.O.BY OWNER
CAB CABINET
C.H. CABINET HEATER
CHNL CHANNEL
C.O.CLEAN OUT
CO2 CARBON DIOXIDE
CARP.CARPET
C.W.CASEWORK
C.I.CAST IRON
C.B.CATCH BASIN
CEM CEMENT
CM CENTIMETER
CT CERAMIC TILE
CHBD CHALK BOARD
CLG. CEILING
CLR CLEAR
COL COLUMN
CONC.CONCRETE
CMU CONCRETE MASONRY UNIT
COND CONDUCTIVE
C.S.V CONDUCTIVE SHEET VINYL
CONT.CONTINUOUS
CLL CONTRACT LIMIT LINE
CONTR CONTRACTOR
C.J.CONTROL JOINT
CONV CONVECTOR
C.G.CORNER GUARD
CORR CORRIDOR
C.S.COUNTER SINK
CRS COURSE
C.R.CURTAIN ROD
C.R.-1 CRASH RAIL
DEM DEMOLISH/DEMOLITION
DET.DETAIL
DIAG DIAGONAL
DIA. DIAMETER
DIFF. DIFFUSER
DIM. DIMENSION
DISP.DISPENSER
DO DITTO
DR DOOR
DBL DOUBLE
DN DOWN
DS DOWNSPOUT
DWG.DRAWING
D.F.DRINKING FOUNTAIN
EA EACH
ELEC.ELECTRICAL
ELEC. CAB ELECTRIC CABINET
EPNL ELECTRIC PANEL
EWC ELECTRIC WATER COOLER
EL ELEVATION
ELEV. ELEVATOR
EQ EQUAL
E.O.EQUIPMENT BY OWNER
EX EQUIPMENT, X-RAY
EX.F EXHAUST FAN
(E)EXISTING
EXP. JT.EXPANSION JOINT
EXP'D EXPOSED
EXT EXTERIOR
E.I.F.S.EXTERIOR INSULATION
& FINISH SYSTEM
FB FACE BRICK
F.C.U.FAN COIL UNIT
F.D.C.FIRE DEPARTMENT
CONNECTIONS
F.N.V.FEM. NAPKIN VENDOR
FIN.RAD.FIN TUBE RADIATION
FIN FINISH
F.A.FIRE ALARM
FEC FIRE EXTINGUISHER CAB
FHC FIRE HOSE CABINET
F.H.FIRE HYDRANT
F.P.FIRE PROOFING
FHMS FLAT HEAD MACH.SCREW
FHWS FLAT HEAD WOOD SCREW
FL. FLOOR
F.D.FLOOR DRAIN
FR FRAME
F.S. FINISH SLAB
FT FOOT
FTG FOOTING
FDTN FOUNDATION
FUR FURRING
FUR. CH.FURRING CHANNEL/S
F.W.FULL WIDTH
F.W.C.FABRIC WALL COVERING
GAL GALLON
GALV.GALVANIZED
GI GALVANIZED IRON
GA GAGE
G.C.GENERAL CONTRACT
GL GLASS
G.B.GRAB BAR
GSF GROSS SQUARE FEET
G.W.B.GYPSUM WALL BOARD
HR-1 HANDRAIL
HDNR HARDENER
HDW HARDWARE
HD.WD.HARDWOOD
HTR HEATER
HTG HEATING
HVAC HEATING, VENTILATION
& AIR CONDITIONING
HT HEIGHT
HC HOLLOW CORE
HM HOLLOW METAL
HORIZ HORIZONTAL
HB HOSE BIB
H.C.HOSE CABINET
H.C.U.HOSPITAL CASEWORK UNIT
H.C.T.HOSPITAL CUBICAL TRACK
H.PL. HOT PLATE
H.P.L.HIGH PRESSURE
PLASTIC LAMINATE
H.W.HOT WATER
HR HOUR
INCIN.INCINERATOR
I.D.INSIDE DIAMETER
INSUL. INSULATE(D)(ION)
INS. GL INSULATED GLASS
INT INTERIOR
IV INTRAVENOUS
INV INVERT
JAN JANITOR
JT JOINT
KIT KITCHEN
KO KNOCK OUT
L.C.LABORATORY CASEWORK
LEV LOW EMISSION VEHICLE
LAM LAMINATED
LAV.LAVATORY
L.GL.LEADED GLASS
LH LEFT HAND
LGT LENGTH
LT LIGHT
LT.P LIGHT PANEL
LTWT LIGHT WEIGHT
L.F.LINEAR FEET
LTL LINTEL
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LVR LOUVER
L.P.LOW POINT
MACH MACHINE
M.H.MANHOLE
MFR MANUFACTURER
MARB MARBLE
MAS MASONRY
M.O.MASONRY OPENING
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MC MEDICINE CABINET
MEMB MEMBRANE
MET METAL
MTD MOUNTED
M.T.P.METAL TOILET PARTITION
MET. TM METAL TRIM
M.W.U.MILLWORK UNIT
MIN. MINIMUM
MISC.MISCELLANEOUS
MOD MODULAR
M.H.MOP HOPPER
MOV MOVABLE
MULL MULLION
(N)NEW
NAT NATURAL
N.L. NIGHT LIGHT
N2O NITROUS OXIDE
NRC NOISE REDUCTION COEIF.
N.I.C. NOT IN CONTRACT
N.T.S.NOT TO SCALE
NOM NOMINAL
NO. NUMBER
OBS OBSCURE
O.C.ON CENTER
OPNG OPENING
OPP OPPOSITE
OPH OPPOSITE HAND
O.D.OUTSIDE DIAMETER
OHMS OVAL HEAD MACH. SCREW
OHWS OVAL HEAD WOOD SCREW
OA OVERALL
OH OVERHEAD
O2 OXYGEN
PNT PAINT(ED)
PNL PANEL
P.T.D PAPER TOWEL DISPENSER
P.T.R.PAPER TOWEL RECEPTACLE
P.BD.PARTICLE BOARD
PTN PARTITION
PVMT PAVEMENT
PG.BD.PEG BOARD
PLAS.PLASTER
P.LAM PLASTIC LAMINATE
PL PLATE
PL.GL.PLATE GLASS
PLMB PLUMBING
PMLD PREMOLDED
PWD PLYWOOD
PT POINT
PPGL POLISHED PLATE GLASS
PPTGL POLISHED PLATE
TEMPERED GLASS
PPWGL POLISHED PLATE
WIRE GLASS
PVC POLYVINYL CHLORIDE
PCF POUNDS PER CU.FT.
PSI POUNDS PER SQ. INCH
PSF POUNDS PER SQ.FT.
P.P.POWER PANEL
PCP PRECAST CONCRETE PANEL
PRE. FAB. PREFABRICATED
PREF. PREFINISHED
PSC PRE-STRESS CONC.
PROJ PROJECTION
PL PROPERTY LINE
PTDF PRESSURE TREATED
DOUGLAS FIR
QTY QUANTITY
QT QUARRY TILE
RAD RADIUS
R.W.L.RAIN WATER LEADER
RECPT.RECEPTACLE, ELECTRIC
REC.RECESS(ED)
RE:REFER TO
R.C.P.REFLECTED CEILING PLAN
REFR.REFRIGERATOR
REG. REGISTER
REINF. REINFORCE(D)(ING)
REQ'D REQUIRED
RES RESILIENT
R.C.P.REINF. CONC. PIPE
RET RETURN
RA RETURN AIR
RVS REVERSE
REV REVISION
RH RIGHT HAND
ROW RIGHT OF WAY
R RISER
RVT RIVET
R.D.ROOF DRAIN
RFH ROOF HATCH
R.V.ROOF VENT
RFG ROOFING
RM ROOM
R.F.S.ROOM FINISH SCHEDULE
RO ROOF OPENING
RND ROUND
RBL RUBBLE STONE
S.A.M.F.SELF-ADHERED MEMBRANE
FLASHING
SDL SADDLE
S.N.C.SAN. NAP. CABINET
S.N.D.SAN.NAP.DISPOSER
STC SEALANT
STG SEATING
SECT.SECTION
S.S.SERVICE SINK
S.B.SHAMPOO BOWL
SHTH SHEATHING
SHT SHEET
SH SHELF, SHELVING
SHR SHOWER
SIM. SIMILAR
S SINK
S.DI.SOAP DISPENSER
SPKR SPEAKER
S.F.C. SPECIAL FLR. COATING
S.W.C.SPECIAL WALL COATING
S.O.G SLAB ON GRADE
SPEC.SPECIFICATIONS
SQ SQUARE
SST STAINLESS STEEL
SP STAND PIPE
STD STANDARD
STL STEEL
STER STERILIZER
SD STORM DRAIN
S.G.T.STRUCTURAL GLAZED TILE
STRUCT STRUCTURAL
SUSP.SUSPENDED
S.V.SHEET VINYL
SW SWITCH
SWBD SWITCH BOARD
SYM SYMMETRICAL
T.B.TACKBOARD
T.P.TANGENT POINT
TEL TELEPHONE
TEMP TEMPERATURE
TEMP. GL.TEMPERED GLASS
TER.TERRAZZO
TEX.TEXTURE
THK THICK(NESS)
THR THRESHOLD
T.D.TISSUE DISPENSER
T TOILET (FIXTURE)
TPH TOILET PAPER HOLDER
T&G TONGUE & GROOVE
T.O.S.TOP OF STEEL
T.O.B TOP OF BEAM
T.O.C.TOP OF COLUMN
T.O.F.TOP OF FASCIA
T.O.FTG TOP OF FOOTING
T.O.P.TOP OF PARAPET
T.O.W.TOP OF WALL
TB TOWEL BAR
TYP TYPICAL
U.C.UNDERCUT
U/C UNDER COUNTER
U.C.L.UNDER COUNTER LIGHT
U.L.UNDERWRITERS
LABORATORIES INC.
UNGND UNDERGROUND
U.H.UNIT HEATER
U.V.UNIT VENTILATOR
U.O.N.UNLESS OTHERWISE NOTED
UR URINAL
UPH.UPHOLSTERY
V.T.R.VENT THROUGH ROOF
VENT VENTILATOR
V.I.F.VERIFY IN FIELD
VERT VERTICAL
VEST VESTIBULE
V.C.T.VINYL COMPOSITION TILE
V.W.C. VINYL WALL COVERING
V VINYL
VT VINYL TILE
WSCT WAINSCOT
W WASTE
WC WATER CLOSET
W.L.WATER LINE
WS WEATHER STRIP
WT WEIGHT
WWF WELDED WIRE FABRIC
W.C.D.F.WHEELCHAIR DRINKING
FOUNTAIN
WG WIRE GLASS
W.M.P.WIRE MESH PARTITION
W/WITH
W/O WITHOUT
WD WOOD
W.R.B. WATER-RESISTANT BARRIER
(WEATHER-RESISTANT
BARRIER)
ABBREVIATIONS
*NOTE -FIRE SUPPRESSION SYSTEM BUILT INTO HOOD AND COMMERCIAL KITCHEN
WEST MACARTHUR
MA
I
N
S
T
R
E
E
T
55
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATE OF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
US
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
3/
9
/
2
0
2
6
4
:
2
5
:
0
6
P
M
G-001
PROJECT INFORMATION
2510
Au
t
h
o
r
SHEET # SHEET NAME
1 - GENERAL
G-001 PROJECT INFORMATION
G-101 GENERAL NOTES
G-110 CALIFORNIA GREEN BUILDING STANDARD CODE
G-111 CALIFORNIA GREEN BUILDING STANDARD CODE
G-112 CALIFORNIA GREEN BUILDING STANDARD CODE
G-113 CALIFORNIA GREEN BUILDING STANDARD CODE
G-120 CODE ANALYSIS
G-140 ADA SITE AND PARKING DETAILS
G-141 ACCESSIBILITY DETAILS & NOTES
G-142 ACCESSIBILITY DETAILS & NOTES
2 - ARCHITECTURE
A-001 AS-BUILT REFERENCE
A-010 SITE PLAN
A-100 DEMO FLOOR PLAN
A-200 FLOOR PLAN
A-201 FINISH FLOOR PLAN
A-210 RCP AND ROOF PLAN
A-300 SECTIONS
A-310 EXTERIOR ELEVATIONS
A-400 ENLARGED PLANS
A-401 INTERIOR ELEVATIONS
A-402 INTERIOR ELEVATIONS
A-500 DETAILS
A-501 DETAILS
A-600 DOOR AND WINDOW SCHEDULE
A-700 EQUIPMENT CUTSHEETS
A-701 EQUIPMENT CUTSHEETS
3 - MECHANICAL
M-001 MECHANICAL COVER SHEET
M-200 MECHANICAL PLANS
M-500 MECHANICAL DETAILS
M-700 MECHANICAL CUTSHEETS
M-701 MECHANICAL CUTSHEETS
M-702 WALK-IN REFRIGERATOR
M-800 TITLE 24 COMPLIANCE
4 - ELECTRICAL
E-001 ELECTRICAL COVER SHEET
E-200 ELECTRICAL PLANS
E-600 PANEL AND SINGLE LINE DIAGRAM
E-700 ELECTRICAL CUTSHEETS
5 - PLUMBING
P-001 PLUMBING COVER SHEET
P-200 PLUMBING PLANS
P-500 PLUMBING DETAILS
P-700 PLUMBING CUTSHEETS
P-701 PLUMBING CUTSHEETS
P-800 TITLE 24 COMPLIANCE
TOTAL: 43
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 03/09/2026
OCCUPANCY LEGEND
1006.3.3 EGRESS BASED ON OCCUPANT LOAD
EACH STORY AND OCCUPIED ROOF SHALL HAVE THE MINIMUM NUMBER OF SEPARATE AND DISTINCT
EXITS, OR ACCESS TO EXITS, AS SPECIFIED IN TABLE 1006.3.3. A SINGLE EXIT OR ACCESS TO A SINGLE
EXIT SHALL BE PERMITTED IN ACCORDANCE WITH SECTION 1006.3.4. THE REQUIRED NUMBER OF
EXITS, OR EXIT ACCESS STAIRWAYS OR RAMPS PROVIDING ACCESS TO EXITS, FROM ANY STORY OR
OCCUPIED ROOF SHALL BE MAINTAINED UNTIL ARRIVAL AT THE EXIT DISCHARGE OR A PUBLIC WAY.
1017.2 LIMITATIONS
EXIT ACCESS TRAVEL DISTANCE
SHALL NOT EXCEED THE VALUES
GIVEN IN TABLE 1017.2
1010.1.1 SIZE OF DOORS
THE REQUIRED CAPACITY OF EACH
DOOR OPENING SHALL BE SUFFICIENT
FOR THE OCCUPANT LOAD THEREOF
AND SHALL PROVIDE A MINIMUM
CLEAR OPENING WIDTH OF 32 INCHES
(813 MM). THE CLEAR OPENING WIDTH
OF DOORWAYS WITH SWINGING
DOORS SHALL BE MEASURED
BETWEEN THE FACE OF THE DOOR
AND THE STOP, WITH THE DOOR
OPEN 90 DEGREES (1.57 RAD). WHERE
THIS SECTION REQUIRES A MINIMUM
CLEAR OPENING WIDTH OF 32 INCHES
(813 MM) AND A DOOR OPENING
INCLUDES TWO DOOR LEAVES
WITHOUT A MULLION, ONE LEAF
SHALL PROVIDE A MINIMUM CLEAR
OPENING WIDTH OF 32 INCHES (813
MM).
1005.3.2 OTHER EGRESS
COMPONENTS
THE CAPACITY, IN INCHES, OF MEANS
OF EGRESS COMPONENTS OTHER
THAN STAIRWAYS SHALL BE
CALCULATED BY MULTIPLYING THE
OCCUPANT LOAD SERVED BY SUCH
COMPONENT BY A MEANS OF EGRESS
CAPACITY FACTOR OF 0.2 INCH (5.1
MM) PER OCCUPANT.
1005.3.2 OTHER EGRESS COMPONENTS
THE CAPACITY, IN INCHES, OF MEANS OF EGRESS COMPONENTS OTHER THAN STAIRWAYS SHALL BE
CALCULATED BY MULTIPLYING THE OCCUPANT LOAD SERVED BY SUCH COMPONENT BY A MEANS OF
EGRESS CAPACITY FACTOR OF 0.2 INCH (5.1 MM) PER OCCUPANT.
CODE ANALYSISEGRESS BASED ON OCCUPANT LOAD ACCESS TRAVEL
1-500
501 - 1,000
2
3
4
MINUMUN NUMBER OF EXITS OR
ACCESS TO EXITS FROM STORY
MORE THEN 1,000
OCUPANT LOAD
PER STORY
TABLE 1006.3.3
MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY
TABLE 1017.2
EXIT ACCESS TRAVEL DISTANCEª
A,E,F-1,M,S-1
OCCUPANCY WITHOUT SPRINKLER
SYSTEM (FEET)
WITH SPRINKLER
SYSTEM (FEET)
200e 250b
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
NOT PERMITTED
200
300
150
200c
200c
200c
R-2.1
B
F-2, S-2, U
H-1
H-2
H-3
H-4
H-5
I-2, I-2.1, I-3f
I-4
L
TOTAL
OCCUPANTS 49250b
300b
400b
75b
100b
150b
175b
200b
B BUSINESS A-2 ASSEMBLY NO OCCUPANTS
- EXIT REQUIRED:
OCCUPANT LOAD: 49 OCC
OCCUPANCY: B - BUSINESS
EXITS REQUIRED (CBC TABLE 1006.3.3): 2
EXIT PROVIDED: 2 (1 EGRESS FROM KITCHEN)
A - HEIGHT OF ACCESSORIES
CBC 11B SECTION 11B-603.5
WHERE TOWEL OR SANITARY NAPKIN DISPENSERS, WASTE RECEPTACLES, OR OTHER ACCESSORIES
ARE PROVIDED IN TOILET FACILITIES, AT LEAST ONE OF EACH TYPE SHALL BE LOCATED ON AN
ACCESSIBLE ROUTE. ALL OPERABLE PARTS, INCLUDING COIN SLOTS, SHALL BE 40 INCHES (1016 MM)
MAXIMUM ABOVE THE FINISH FLOOR.
B - ACCESSIBLE ROUTE TO ACCESSIBLE COMPARTMENT
CBC 11B SECTION 11B-403.5.1 EXCEPTIONS: 5
THE CLEAR WIDTH FOR ACCESSIBLE ROUTES TO ACCESSIBLE TOILET COMPARTMENTS SHALL BE 44
INCHES (1118 MM) EXCEPT FOR DOOR-OPENING WIDTHS AND DOOR SWINGS.
C - STALL WIDTH
CBC 11B SECTION 11B-604.8.1.1
WHEELCHAIR ACCESSIBLE COMPARTMENTS SHALL BE 60 INCHES (1524 MM) WIDE MINIMUM MEASURED
PERPENDICULAR TO THE SIDE WALL, AND 56 INCHES (1422 MM) DEEP MINIMUM FOR WALL HUNG WATER
CLOSETS AND 59 INCHES (1499 MM) DEEP MINIMUM FOR FLOOR MOUNTED WATER CLOSETS MEASURED
PERPENDICULAR TO THE REAR WALL. WHEELCHAIR ACCESSIBLE COMPARTMENTS SHALL ADDITIONALLY
PROVIDE MANEUVERING SPACE COMPLYING WITH SECTION 11B-604.8.1.1.1, 11B-604.8.1.1.2, OR 11B-
604.8.1.1.3, AS APPLICABLE. WHEELCHAIR ACCESSIBLE COMPARTMENTS FOR CHILDREN'S USE SHALL BE
60 INCHES (1524 MM) WIDE MINIMUM MEASURED PERPENDICULAR TO THE SIDE WALL, AND 59 INCHES
(1499 MM) DEEP MINIMUM FOR WALL HUNG AND FLOOR MOUNTED WATER CLOSETS MEASURED
PERPENDICULAR TO THE REAR WALL.
D - ACCESSIBLE STALL DOOR
CBC 11B Section 11B-604.8.1.2
TOILET COMPARTMENT DOORS, INCLUDING DOOR HARDWARE, SHALL COMPLY WITH SECTION 11B-404
EXCEPT THAT IF THE APPROACH IS FROM THE PUSH SIDE OF THE COMPARTMENT DOOR, CLEARANCE
BETWEEN THE DOOR SIDE OF THE COMPARTMENT AND ANY OBSTRUCTION SHALL BE 48 INCHES (1219
MM) MINIMUM MEASURED PERPENDICULAR TO THE COMPARTMENT DOOR IN ITS CLOSED POSITION.
DOORS SHALL BE LOCATED IN THE FRONT PARTITION OR IN THE SIDE WALL OR PARTITION FARTHEST
FROM THE WATER CLOSET. WHERE LOCATED IN THE FRONT PARTITION, THE DOOR OPENING SHALL BE
4 INCHES (102 MM) MAXIMUM FROM THE SIDE WALL OR PARTITION FARTHEST FROM THE WATER
CLOSET. WHERE LOCATED IN THE SIDE WALL OR PARTITION, THE DOOR OPENING HINGE SIDE JAMB FOR
OUT SWINGING DOORS SHALL BE FARTHEST FROM THE WATER CLOSET AND THE STRIKE SIDE JAMB
SHALL BE 54 INCHES (1372 MM) MINIMUM FROM THE REAR WALL. THE DOOR SHALL BE SELF-CLOSING. A
DOOR PULL COMPLYING WITH SECTION 11B-404.2.1 SHALL BE PLACED ON BOTH SIDES OF THE DOOR
NEAR THE LATCH. DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED
FOR ANY FIXTURE. DOORS MAY SWING INTO THAT PORTION OF MANEUVERING SPACE WHICH DOES NOT
OVERLAP THE CLEARANCE REQUIRED AT A WATER CLOSET.
E - STANDING PERSON DRINKING FOUNTAIN
CBC 11B SECTION 11B-602.7
SPOUT OUTLETS OF DRINKING FOUNTAINS FOR STANDING PERSONS SHALL BE 38 INCHES (965 MM)
MINIMUM AND 43 INCHES (1092 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
CBC 11B SECTION 11B-211.2
NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. WHEN PROVIDED, ONE DRINKING
FOUNTAIN SHALL COMPLY WITH SECTIONS 11B-602.1 THROUGH 11 B- 602.6, 11B-602.8 AND 11 B-602.9 AND
ONE DRINKING FOUNTAIN SHALL COMPLY WITH SECTION 11B-602.7 AND 11B-602.9.
F - ENTRY DOOR MANUEVERING CLEARANCE
CBC 11B SECTION 11B-404.2.4.1
SWINGING DOORS AND GATES SHALL HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE
11B-404.2.4.1.
G - CLEARANCE IN FRONT OF TOILET
CBC 11B SECTION 11B-604.3.1
CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES (1524 MM) MINIMUM MEASURED
PERPENDICULAR FROM THE SIDE WALL AND 56 INCHES (1422 MM) MINIMUM MEASURED PERPENDICULAR
FROM THE REAR WALL. A MINIMUM 60 INCHES (1524 MM) WIDE AND 48 INCHES (1219 MM) DEEP
MANEUVERING SPACE SHALL BE PROVIDED IN FRONT OF THE WATER CLOSET.
H - URINAL
CBC 11B SECTION 11B-605.2
URINALS SHALL BE THE STALL-TYPE OR THE WALL-HUNG TYPE WITH THE RIM 17 INCHES (432 MM)
MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. URINALS SHALL BE 13 1/2 INCHES (343 MM) DEEP
MINIMUM MEASURED FROM THE OUTER FACE OF THE URINAL RIM TO THE BACK OF THE FIXTURE.
1210.3.2 URINAL PARTITIONS
EACH URINAL UTILIZED BY THE PUBLIC OR EMPLOYEES SHALL OCCUPY A SEPARATE AREA WITH WALLS
OR PARTITIONS TO PROVIDE PRIVACY. THE WALLS OR PARTITIONS SHALL BEGIN AT A HEIGHT NOT
MORE THAN 12 INCHES (305 MM) FROM AND EXTEND NOT LESS THAN 60 INCHES (1524 MM) ABOVE THE
FINISHED FLOOR SURFACE. THE WALLS OR PARTITIONS SHALL EXTEND FROM THE WALL SURFACE AT
EACH SIDE OF THE URINAL NOT LESS THAN 18 INCHES (457 MM) OR TO A POINT NOT LESS THAN 6
INCHES (152 MM) BEYOND THE OUTERMOST FRONT LIP OF THE URINAL MEASURED FROM THE FINISHED
BACKWALL SURFACE, WHICHEVER IS GREATER.
I - PIPE AT LAVATORIES
CBC 11B SECTION 11B-606.5
WATER SUPPLY AND DRAIN PIPES UNDER LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE
CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES
UNDER LAVATORIES AND SINKS.
J - SIDE GRAB BAR
CBC 11B SECTION 11B-604.5.1
THE SIDE WALL GRAB BAR SHALL BE 42 INCHES (1067 MM) LONG MINIMUM, LOCATED 12 INCHES (305 MM)
MAXIMUM FROM THE REAR WALL AND EXTENDING 54 INCHES (1372 MM) MINIMUM FROM THE REAR WALL
WITH THE FRONT END POSITIONED 24 INCHES (610 MM) MINIMUM IN FRONT OF THE WATER CLOSET.
K - REAR GRAB BAR LENGTH
CBC 11B SECTION 11B-604.5.2
THE REAR WALL GRAB BAR SHALL BE 36 INCHES (914 MM) LONG MINIMUM AND EXTEND FROM THE
CENTERLINE OF THE WATER CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND 24 INCHES
MINIMUM ON THE OTHER SIDE.
L - OPERABLE PARTS (DOOR)
11B-309.4
OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING,
PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL
BE 5 POUNDS (22.2 N) MAXIMUM
44" MIN. ACCESSIBLE PATH OF TRAVEL
INDICATES EGRESS ROUTE DIRECTON
EXIT SIGN, SINGLE FACE, W/DIRECTIONAL ARROW AS INDICATED,
MOUNTED ON RECESSED CEILING OUTLET BOX.
EXIT SIGN, DOUBLE FACE, W/DIRECTIONAL ARROWS AS INDICATED,
MOUNTED ON RECESSED CEILING OUTLET BOX
EXIT SIGN, SINGLE FACE, NON DIRECTIONAL ARROW, MOUNTED ON
RECESSED CEILING OUTLET BOX.
62'-5" MAX DIAG.
503 SF
COOK
PREP
543 SF
OPEN
DINING
53 SF
RESTROOM
37 SF
STORAGE
TO
T
A
L
L
E
N
G
T
H
6
8
'
-0"
OCCUPANCY: ASSEMBLY A-2 - (TABLE 422.1 CALIFORNIA PLUMBING CODE)
TOTAL OCCUPANT LOAD: 49 (25 MALE, 25 FEMALE)
PLUMBING FIXTURES REQUIRED (TABLE 422.1 PLUMBING CODE)
REQUIRED WATER
CLOSET URINAL LAVATORIES DRINKING
FOUNTAIN SERVICE SINK
MALE 1 1 1
. .
1 N/A 1FEMALE
CPC 422.1
EXCEPTION (3)
IN BUSINESS AND MERCANTILE OCCUPANCIES WITH A TOTAL OCCUPANT LOAD OF 50 OR LESS INCLUDING
CUSTOMERS AND EMPLOYEES, ONE TOILET FACILITY, DESIGNED FOR USE BY NO MORE THAN ONE
PERSON AT A TIME, SHALL BE PERMITTED FOR USE BY BOTH SEXES.
A-2 ASSEMBLY
OCCUPANCY -
RESTAURANTS,
PUBS, LOUNGES,
NIGHTCLUBS
AND BANQUET
HALLS
Male
1: 1-50
2: 51-150
3: 151-300
4: 301-400
Female
1: 1-25
2: 26-50
3: 51-100
4: 101-200
6: 201-300
8: 301-400
Male
1: 1-200
2: 201-300
3: 301-400
4: 401-600
Male
1: 1-150
2: 151-200
3: 201-400
Female
1: 1-150
2: 151-200
3: 201-400
Over 400, add 1
fixture for each
additional 250 males
and 1 fixture for each
125 females.
Over 600,
add 1 fixture
for each
additional
300 males.
Over 400, add 1 fixture
for each additional 250
males and 1 fixture for
each 200 females.
1: 1-250
2: 251-500
3: 501-750
Over 750, add
1 fixture for
each additional
500 persons.
1 service
sink or
laundry
tray
-
PROVIDED ONE UNISEX RESTROOM IS COMPLIANT TO SERVICE THE EXISTING SQUARE
FOOTAGE AND OCCUPANT LOAD.
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATE OF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
3/
9
/
2
0
2
6
4
:
2
5
:
0
7
P
M
G-120
CODE ANALYSIS
2510
Au
t
h
o
r
00 EGRESS LEGEND
EGRESS LEGEND
OCCUPANCY LOAD SCHEDULE
NAME OCC. TYPE AREA DEPARTMENT OCC. LOAD FACTOR
OCC.
LOAD
OPEN DINING 543 SF A2 - ASSEMBLY 15 SF 37
COOK PREP 503 SF B - BUSINESS 50 SF 11
RESTROOM 53 SF NONE 0 SF
STORAGE 37 SF STORAGE 150 SF 1
49
1/4" = 1'-0"CODE ANALYSIS PLAN 1
N
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 03/09/2026
PLUMBING FIXTURE CALCULATIONS
WEST MACARTHUR BLVD
MA
I
N
S
T
R
E
E
T
PROJECT
LOCATION
(E) GAS
STATION
EV
SPACE
(E) TRASH
ENCLOSURE
(E) ROOF
COVER OF
GAS STATION
G-140
5
TYP.
G-140
5
TYP.
G-140
2
TYP.
G-140
14
TYP.
(E) ACCESSIBLE
PARKING
(E) ACCESSIBLE
PARKING
G-140
8
TYP.
(E) DETECTABLE
WARNING, TYP.(E) DETECTABLE
WARNING, TYP.
(E) ACC.
SIGNAGE, TYP.
SEE SHEET G-140
(E) TRANSFORMER(E) TRASH
ENCLOSURE
A-210
3
NO PARKING
(E) GGI TANK
(E) GAS AND
WATER METERS
ARCHITECTURAL
LAYOUT - LAYOUT AND VERIFY ALL DIMENSIONS PRIOR TO START OF WORK. BRING DISCREPANCIES TO
THE ARCHITECT’S ATTENTION.
CONCRETE PAVING SAWCUT
SAWCUT EXISTING REINFORCED CONCRETE WALKWAYS AS REQUIRED FOR NEW WORK. DOWEL AND
EPOXY REBAR AT FACE OF SAWCUT WHERE EXISTING WORK IS TO REMAIN. SEE STRUCTURAL
DRAWINGS. ALL CONCRETE SHALL BE PORTLAND CEMENT CONCRETE WITH ULTIMATE 28 DAY MINIMUM
COMPRESSIVE STRENGTH OF 3,000 PSI UNLESS NOTED OTHERWISE IN OWNER’S GEO-TECHNICAL
REPORT.
NOISE LEVEL COMPLIANCE
COMPLY WITH LOCAL NOISE LEVELS DURING NORMAL BUSINESS HOURS AND OBTAIN PERMISSION FOR
AFTER-HOURS CONSTRUCTION ACTIVITY WHEN APPLICABLE. DIRECT NOISE COMPLAINTS TO THE
CONSTRUCTION MANAGER.
CLEAN JOBSITE
AT THE CONCLUSION OF EACH WORK DAY, LEAVE SITE CLEAN, NEAT AND ORDERLY WITH MATERIALS
AND EQUIPMENT LOCATED TO AVOID SAFETY CONCERNS. CONTRACTOR HAS SOLE RESPONSIBILITY
FOR JOBSITE SAFETY.
GEO-TECHNICAL REPORT
SEE OWNER’S GEOTECHNICAL REPORT FOR SUBGRADE AND COMPACTION CRITERIA UNDER
PAVEMENT.
EXPANSION / CONTROL JOINTS
CONCRETE WALKS SHALL RECEIVE EXPANSION JOINTS AT 15'-0" O.C. MAX AND CONTROL JOINTS AT 5'-0"
O.C. MAX UNLESS OTHERWISE NOTED
PARKING STALL STRIPING
ALL PARKING STALL STRIPING SHALL BE PER LOCAL JURISDICTION STANDARDS.
DIMENSIONS
ALL DIMENSIONS ON SITE PLAN ARE TO BE FACE OF WALL FINISH, FACE OF CONCRETE CURB,
PROPERTY LINE OR CENTERLINE OF PARKING STALL, UNLESS NOTED OTHERWISE.
EXISTING WORK
ALL EXISTING WORK IS TO REMAIN UNLESS NOTED OTHERWISE. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR REPAIRING OR REPLACING AT THE CONTRACTOR’S EXPENSE ANY EXISTING ITEM
DAMAGED BY CONSTRUCTION AND, OR DEMOLITION ACTIVITY. THE DAMAGED ITEMS SHALL BE
RESTORED TO AN “AS-WAS” OR BETTER CONDITION, OR REPLACES AT THE OWNER’S DISCRETION.
WASTE MANAGEMENT
CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTION WASTE MANAGEMENT COMPLIANCE DEFINED BY
LOCAL GREEN BUILDING ORDNANCE(S), INCLUDING BUT NOT LIMITED TO SORTING AND SEPARATING
MATERIALS DERIVED FROM CONSTRUCTION AND DEMOLITION DEBRIS INCLUDING BUT NOT LIMITED TO
CONCRETE, REINFORCING STEEL AND ASPHALT.
TRAFFIC & PEDESTRIAN ACCESS
SCHEDULE CONSTRUCTION WASTE MATERIAL REMOVAL IN A MANNER TO INSURE MINIMUM
INTERFERENCE WITH VEHICLE TRAFFIC AND PEDESTRIAN ACCESS INCLUDING ADJACENT PROPERTIES
WHEN APPLICABLE, PER LOCAL REQUIREMENTS.
SITE DRAINAGE
CONTRACTOR SHALL MAINTAIN NECESSARY TEMPORARY SITE DRAINAGE DURING DEMOLITION AND
CONSTRUCTION ACTIVITY.
LANDSCAPE PROTECTION
PROTECT EXISTING PLANTING AREAS INCLUDING TREES, SHRUBS, TURF AND IRRIGATION SYSTEM
SHOWN TO REMAIN. COORDINATE NEW WORK WITH EXISTING AS-BUILT FIELD CONDITIONS. SEE
LANDSCAPE DRAWINGS.
CONSTRUCTION BARRICADES
CONTRACTOR BEARS SOLE RESPONSIBILITY FOR CONSTRUCTION BARRICADES, PROTECTIVE
CANOPIES AND OTHER FORMS OF PROTECTION AS REQUIRED TO PROTECT OWNER’S PERSONNEL,
BUILDING TENANTS AND THE GENERAL PUBLIC FROM INJURY DURING CONSTRUCTION.
DAMAGE REPAIR
PROMPTLY REPAIR DAMAGE WHEN OCCURS AT NO ADDITIONAL COST TO OWNER.
DUST CONTROL
USE TEMPORARY ENCLOSURES OR OTHER SUITABLE METHODS SUCH AS WATERING TO CONTROL
DUST IN ACCORDANCE WITH LOCAL JURISDICTION.
EQUIPMENT
EQUIPMENT STORED ON SITE AWAITING INSTALLATION SHALL BE PROTECTED FROM PHYSICAL
DAMAGE.
PROPERTY LINE
LIMIT OF WORK
ACCESSIBLE PATH OF TRAVEL
ACCESSIBLE ROUTE TO PUBLIC RIGHT OF WAY
PRIMARY BUILDING ENTRANCE
SECONDARY BUILDING ENTRANCES
INTERIOR AND ROOF RENOVATION
AREA N.I.C.
AREA OF IMPROVEMENT
KEYNOTE TAGD20 / 10
(E) ROOF WELL AND
MECHANICAL UNIT
19' - 4"
11
'
-
8
"
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATE OF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
3/
9
/
2
0
2
6
4
:
2
5
:
0
8
P
M
A-010
SITE PLAN
2510
Au
t
h
o
r
1" = 20'-0"SITE PLAN 1
GENERAL NOTES
SITE LEGEND
N
(E) SITE PLAN FROM OTHER PERMIT SET. NOT TO SCALE. FOR REFERENCE ONLY
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 03/09/2026
1. ALL FOOD AND UTENSIL RELATED EQUIPMENT TO BE ANSI CERTIFIED FOR SANITATION.
2. DRY STORAGE SHELVING A MIN 32 IN FT. ALL SHELVING MUST BE ACCESSIBLE WITH 30"
AISLE CLR. THE SHELVING UNIT SHALL BE A MIN. 18" IN DEPTH AND 3 TIERS HIGH.
3. SNEEZEGUARD FOR DISPLAYS OF UNPACKAGED FOOD SHALL BE SHIELDED SO AS TO
INTERCEPT A DIRECT LINE BETWEEN THE CUSTOMERS' MOUTH, ASSUMED TO BE BETWEEN
54' AND 60" ABOVE THE FLOOR, AND THE FOOD BEING DISPLAYED.
4. THE FOOD PREP. SINK (S.S) SHALL BE WITH AN INTEGRALLY INSTALLED DRAIN BOARD. THE
WASTE FROM THE SINK MUST DRAIN INTO FLOOR SINK, AN INDIRECT CONNECTION.
5. THE DRAIN TO FLOOR SINK SHALL BE MIN. 1/4" SLOPE PER FOOT, THE PIPE AT LEAST 6"
ABOVE THE FLOOR AND WITH 1" AIR GAP. THE FLOOR SINK MUST BE AT LEAST HALF-
EXPOSED OR BE IN-LINE WITH THE FRONT FACE OF ELEVATED FREESTANDING EQUIPMENT
AND WITHIN 15FT OF THE CONDENSATE PRODUCING EQUIPMENT.
6. A DOOR-ACTIVATED AIR CURTAIN DEVICE THAT DELIVERS AN AIR VELOCITY OF AT LEAST
750 FEET PER MINUTE, MEASURED 3FT. ABOVE THE FLOOR, MUST BE PROVIDED OVER THE
DELIVERY DOOR. THE AIR CURTAIN SHALL COVER THE ENTIRE WIDTH OF THE DOOR. FOR
DELIVERY DOOR THAT ARE WIDER THAN 4 FT., THE AIR CURTAIN MUST PRODUCE AN AIR
VELOCITY OF AT LEAST 1600 FT PER MIN. AS MEASURED 3 FT ABOVE THE FLOOR.
7. ALL EQUIPMENT WHICH GENERATES CONDENSATE OR SIMILAR LIQUID WASTES SHALL BE
DRAINED BY MEANS OF INDIRECT WASTE PIPES INTO FLOOR SINK. FLOOR DRAINS ARE NOT
TO BE USED IN LIEU OF FLOOR SINKS. ALL FLOOR SINKS MUST BE AT LEAST HALF-EXPOSED
AND BE IN LINE WITH THE FRONT FACE OF ELEVATED FREESTANDING EQUIPMENT, AND
WITHIN 15 FT OF THE CONDENSATE PRODUCING EQUIPMENT.
8. ALL SINKS MUST BE WITH HOT (MIN. 120 F) AND COLD WATER FOR MIXING FAUCETS.
9. A MIN. 50-FOOT CANDLES OF LIGHT MEASURED 30" AFF. IN KITCHEN, SERVICE & WASHING
AREA, THOUGH OUT FACILITY FOR DURING GENERAL CLEANING UP ACTIVITY AND MIN. 10-
FOOT CANDLES OF LIGHT MEASURED 30" AFF. IN RESTROOM AND STORAGE ROOMS.
10. ALL EXISTING EQUIP. IN GOOD WORKING CONDITION IN COMPLIANCE WITH HEALTH CODE.
11. THE GREASE INTERCEPTOR MUST BE LOCATED OUTSIDE OF THE FOOD ESTABLISHMENT.
12. THE POT SINK SHALL BE CONNECTED DIRECTLY TO THE DRAINAGE SYSTEM WITH A F/D.
THE FIXTURE SHALL BE CONNECTED ON THE SEWER SIDE OF THE FLOOR DRAIN TRAP.
HWR
(E)W
SOV IN YB
S OR W
S OR W
ABBREVIATION
POC
COTG
GC
CV
SOV
COYB
WCO
(E) G
G
HWR
(E) G
G
FCO
HW
CD
CW
CD
V
SYMBOL
POINT OF CONNECTION
CLEANOUT TO GRADE
WALL CLEANOUT
CLEANOUT IN YARDBOX
SHUT-OFF VALVE IN YARD BOX
CHECK VALVE
SHUT-OFF VALVE
GAS COCK
HOT WATER RETURN
GAS (LOW PRESSURE)
EXISTING GAS
HOT WATER
FLOOR CLEANOUT
EXISTING SOIL OR WASTE
SANITARY VENT
COLD WATER
CONDENSATE DRAIN
SOIL OR WASTE (BELOW GRADE)
DESCRIPTION
SOIL OR WASTE (ABOVE GRADE)
(E) CW (E) CW EXISTING COLD WATER
(E) HW (E) HW EXISTING HOT WATER
(E) HWR (E) HWR EXISTING HOT WATER RETURN
(E) CD (E) CD EXISTING CONDENSATE DRAIN
(E) V (E) V EXISTING VENT
(E) W (E) W EXISTING WASTE
POD POINT OF DISCONNECT
UP UP PIPING
DOWN DOWN PIPING
WHA WATER HAMMER ARESTOR
TP TRAP PRIMER
1.5
ABOVE 350
251 - 350
141 - 200
105 - 140
NOMINAL PIPE DIAMETER (IN INCHES)
INSULATION THICKNESS REQUIRED
(IN INCHES)
<1
1
TO
<1.5
TO
<4
1.5
TO
<8
41 8
AND
LARGER
TO
0.32 - 0.34
0.29 - 0.31
0.27 - 0.30
0.25 - 0.29
0.22 - 0.28
250
200
150
125
100
4.5
3.0
2.5
1.5
1.0
5.0
4.0
2.5
1.5
1.5
5.0
4.5
2.5
2.0
1.5
5.0
4.5
3.0
2.0
1.5
5.0
4.5
3.0
2.0
40 - 60 0.21 - 0.27 75 0.5 0.5 1.0 1.0 1.0
BELOW 40 0.20 - 0.26 50 1.0 1.5 1.5 1.5 1.5
201 - 250
INSULATION
MEAN RATING
TEMPERATURE
(°F)
CONDUCTIVITY
RANGE (IN
BTU-INCH PER
HOUR PER
SQUARE FOOT
PER °F)
FLUID
TEMPERATURE
RANGE (°F)
SPACE HEATING, HOT WATER (STEAM, STEAM CONDENSATE & HOT WATER) AND SERVICE WATER
HEATING SYSTEMS. ALL HOT WATER LINES TO BE INSULATED PER CPC 609.11
SPACE COOLING SYSTEMS (CHILLED WATER, HVAC CONDENSATE, REFRIGERANT AND BRINE)
TABLE 120.3-A PIPE INSULATION THICKNESS
1. FOR NEW POST INSTALLED ANCHORAGE (E.G. MECHANICAL OR CHEMICAL ANCHORAGES, ETC.)
INTO EXISTING CONCRETE, FULLY OR PARTIALLY GROUTED CONCRETE MASONRY UNIT, ETC.,
LOCATE AND IDENTIFY ALL EXISTING REINFORCING, PT TENDONS, EMBEDDED CONDUITS, ETC.,
WITHIN THE AREA OF THE NEW ANCHORAGE VIA NON-DESTRUCTIVE METHODS (E.G. GROUND
PENETRATING RADAR (GPR), X-RAY, ETC.), PRIOR TO POST INSTALLATION IN ORDER TO ENSURE
THAT THE NEW ANCHORAGE DOES NOT CUT, DAMAGE, CHIP, OR ADVERSELY IMPACT THE
INTEGRITY OF THE EXISTING STRUCTURAL AND NON-STRUCTURAL ELEMENTS AND COMPONENTS.
AS-BUILT DRAWINGS CAN BE PROVIDED UPON REQUEST.
2. NO CORING OF ANY KIND THROUGH EXISTING STRUCTURAL AND NON-STRUCTURAL ELEMENTS
AND COMPONENTS (E.G. SLABS, BEAMS, COLUMNS, WALLS, ETC.) SHALL OCCUR WITHOUT
APPROVAL FROM SEOR. FOR ALL CORED PENETRATIONS THAT ARE APPROVED BY SEOR, THESE
CORING LOCATIONS MUST BE CLEARLY IDENTIFIED ON THE DRAWINGS AND MARKED IN THE FIELD
DURING CONSTRUCTION WITH DIMENSIONS, SIZE, ETC. LOCATE AND IDENTIFY ALL EXISTING
REINFORCING, PT TENDONS, EMBEDDED CONDUITS, ETC., WITHIN THE AREA OF THE CORED
PENETRATIONS VIA NON-DESTRUCTIVE METHODS, (E.G. X-RAY, ETC.) AT ANY STRUCTURAL AND
NON-STRUCTURAL ELEMENT AND COMPONENT IN ORDER TO AVOID CUTTING, DAMAGING,
CHIPPING, OR ADVERSELY IMPACTING THE INTEGRITY OF THESE EXISTING ELEMENTS AND
COMPONENTS. AS-BUILT DRAWINGS CAN BE PROVIDED UPON REQUEST.
3. ALL POST-INSTALLED ANCHORAGE, FASTENERS, ETC. REQUIRED FOR ATTACHING AND/OR
SECURING BOTH STRUCTURAL AND NON-STRUCTURE ELEMENTS AND COMPONENTS SHALL HAVE
A CURRENT AND VALID PRODUCT TESTING AND ACCEPTANCE DOCUMENT THAT VERIFIES ITS
APPLICABLE USE AND COMPLIANCE WITH THE APPROPRIATE GOVERNING CODES FOR THE
PROJECT (E.G. ICC-ESR, IAPMO, LARR, ECT.)
4. FOR UNIQUE SITUATIONS WHERE THE ABOVE CANNOT BE ACHIEVED, THOSE CONDITIONS MUST
BE BROUGHT UP TO THE OWNER AND SEOR ENGINEERING FOR FURTHER EVALUATION
AND ASSESSMENT.
SERVICES LOCATION
DOMESTIC
COLD
& HOT WATER
UNDERGROUND
ABOVE GROUND
MATERIAL
RIGID COPPER (TYPE K)
JOINING METHOD
LEAD FREE
BRAZED OR
PROPRESS
REMARKS
RIGID COPPER (TYPE L)
SANITARY
WASTE/
SEWER
UNDERGROUND CPVC SCHEDULE 40 HUBLESS
ABOVE GROUND CPVC SCHEDULE 40 HUBLESS
SANITARY VENT
ABOVE GROUND
(INDOOR)
CAST IRON SOIL PIPE &
FITTINGS HUBLESS
STORM DRAIN UNDERGROUND
ABOVE GROUND
(INDOOR)
CAST IRON SOIL PIPE HUBLESS
CAST IRON SOIL PIPE HUBLESS
ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE
SLEEVES IN COMPLIANCE WITH CPC 313.0 AND 313.10.
NOTE: 1. ALL BRAZED AND SOLDERED JOINTS SHALL BE LEAD FREE. EXPOSED VENT PIPE SHALL BE GALVANIZED PER PLUMBING SPECIFICATIONS
2. ALL EXISTING CONDENSATE PIPING ABOVE CEILING SHALL BE PROVIDED WITH 1/2" ARMAFLEX INSULATION FOR CONDENSATION CONTROL.
3. ALL CAST IRON PIPES BELOW GRADE SHALL BE SPIRAL WRAPPED WITH 20 MIL. VISQUEEN TAPE.
LEAD FREE
SOLDERED OR
PROPRESS
ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES IN
COMPLIANCE WITH CPC 313.0 AND 313.10. HOT WATER IS
INSULATED WITH 1-1/2" FIBERGLASS.
ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES IN
COMPLIANCE WITH CPC 313.0 AND 313.10.
ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES IN
COMPLIANCE WITH CPC 313.0 AND 313.10.
ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES
IN COMPLIANCE WITH CPC 313.0 AND 313.10.
ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES IN
COMPLIANCE WITH CPC 313.0 AND 313.10.
ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES
IN COMPLIANCE WITH CPC 313.0 AND 313.10.
UNDERGROUND
ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES
IN COMPLIANCE WITH CPC 313.0 AND 313.10.
CAST IRON SOIL PIPE &
FITTINGS HUBLESS
ABOVE GROUND
& (INDOOR)
THREADED
WELDED
ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES IN
COMPLIANCE WITH CPC 313.0 AND 313.10. EXPOSED PIPE
SHALL BE PAINTED GAS CO. GRAY.
LOW PRESSURE GAS
ABOVE GROUND
(EXTERIOR)
ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES
IN COMPLIANCE WITH CPC 313.0 AND 313.10.
CAST IRON SOIL PIPE &
FITTINGS HUBLESS
CONDENSATE
SCHEDULE 40 BLACK STEEL
2" & SMALLER - THREADED
2 1/2" & LARGER - WELDED
ALL PIPE PENETRATION SHALL BE PROVIDED WITH PIPE SLEEVES IN
COMPLIANCE WITH CPC 313.0 AND 313.10. INSULATE WITH
1/2"ARMAFLEX FOR CONDENSATION CONTROL
ABOVE GROUND
(INDOOR)RIGID COPPER (TYPE M)
LEAD FREE
BRAZED OR
PROPRESS
ABOVE GROUND
(ON ROOF)CPVC SCHEDULE 80 SOLVENT
CEMENTED
ALL PIPE SUPPORT SHALL BE PROVIDED AS REQUIRED BY CPC
TABLE 313.3. PROVIDE TRANSITION FITTING FROM CPVC PIPE TO
COPPER PIPE ABOVE ROOF.
PLUMBING FIXTURE STANDARD PROPOSED /
EXISTING GPM COMPLY (Y/N)
LOW FLOW REQUIREMENT PER SECTION 5.303.3
HAND WASH SINK
KITCHEN SINK
1.5 GPF
1.8 GPM
PROPOSED
1.5 GPM
PROPOSED
1.8 GPM YES
YES
RR LAVATORY 0.5 GPM PROPOSED 0.5
GPM @60PSI YES
WATER CLOSET 1.8 GPM YESPROPOSED
1.8 GPM
WATER
SANITARY
WASTE
SANITARY
VENT
GAS
INDIRECT
WASTE
STORM
DRAIN
ACID
RESIST
COPPER
-"TY
PE L"
NOTE*
WHEN USING UNDERGROUND ABS/PVC PIPING, SHALL BE
APPROVED BY THE CITY ADMINISTRATIVE AUTHORITY
NOTE*
THE DRAIN PIPE SERVING SODA MACHINES OR SIMILAR
TO PROVIDE ACIS RESISTANCE FOR ABS PIPING
COPP
E
R
-"TY
PE K
"
COPPER
-"TY
PE M
"
BLACK STEE
L -"SCH 4
0
"
EACH HORIZONTAL DRAINAGE PIPE SHALL BE PROVIDED WITH A CLEANOUT AT IT'S
UPPER TERMINAL & EACH RUN OF PIPING, WHIICH IS MORE THAN ONE HUNDRED
FEET IN TOTAL DEVELOPED LENGTH, SHALL BE PROVIDED WITH CLEANOUT AT EACH
HUNDRED FEET OR FRACTION THEREOF IN LENGTH OF SUCH PIPING.
GALV
.
S
T
E
E
L -"SCH 40"
PVC -"SC
H
4
0
"
PVC
-CLA
S
S
315
ABS
INSIDE
OUTSIDE
UNDER
GROUND
LOCAT
ION
SERV
I
C
E
CAST IR
ON
INSIDE
OUTSIDE
INSIDE
OUTSIDE
INSIDE
OUTSIDE
INSIDE
OUTSIDE
INSIDE
INSIDE
WATER PIPER SIZING CALCULATION
PER CHART A 102.2, A 103.1, A 105.1
STREET STATIC WATER PRESSURE: HIGH 76 PSI, LOW 63 PSI
WATER SIZING CALCULATION FOR 23.5 FU
MIN. STREET WATER PRESSURE:
1" WATER METER PRESSURE LOSS:
MINUS 1" RPBP PRESSURE LOSS:
MINUS VERTICAL LIFT (4'-0" X 0.434):
MINUS RESIDUAL PRESSURE REQ'D AT FIXTURE:
63 PSI
2 PSI
10 PSI
2 PSI
20 PSI
TOTAL PRESSURE AVAILABLE FOR FRICTION LOSS: 29 PSI
COLD WATER PIPING
HOT WATER PIPING
TOTAL LONGEST LENGTH: 55 FT
PIPE SIZE 1/2"3/4"1"1-1/4"1-1/2"
PIPE SIZE
PIPE SIZE 1/2"3/4"1"1-1/4"
PIPE SIZE
29 PSI X 55 FT / (100 FT X 1.25) T.E.L. =12.8 PSI LOSS PER 100 FT COLD WATER
3 10 26 53
3 6 15 30
85
12.8 PSI LOSS/100 FT;
8 FT/S MAX. VEL.
12.8 PSI LOSS/100 FT;
5 FT/S MAX. VEL.
• REUSE OF EXISTING GGI PLAZA GREASE TRAP. REUSE OF EXISTING UTILITY CONNECTIONS FOR
WATER, GAS, AND SEWER LINES.
• PROVIDE NEW PLUMBING FIXTURES AT ACCESSIBLE UNISEX RESTROOM. NEW PLUMBING
FIXTURES AT KITCHEN SPACE TO BE COMPLIANT WITH LOCAL ENVIRONMENTAL HEALTH CODE.
• PROVIDE NEW TANKLESS WATER HEATER AT ROOF WELL.
• COORDINATION WITH MECHANICAL AND ELECTRICAL EQUIPMENT IN PLENUM SPACE.
110.3 (a) CERTIFICATION BY MANUFACTURERS
ANY SERVICE WATER HEATING SYSTEM OR EQUIPMENT MAY BE INSTALLED ONLY IF CERTIFIED TO THE ENERGY COMMISSION TO MEET ALL APPLICABLE 110.3
REQUIREMENTS
110.3 (a) TEMPERATURE CONTROLS
SERVICE WATER HEATING SYSTEMS SHALL BE EQUIPPED WITH AUTOMATIC TEMPERATURE CONTROLS CAPABLE OF BEING ADJUSTED FROM LOWEST TO HIGHEST
ACCEPTABLE TEMPERATURES FOR THE INTENDED USE AS LISTED IN TABLE 3, CHAPTER 50 OF THE ASHRAE HANDBOOK, HVAC APPLICATIONS VOLUME, OR TABLE
613.1 OF THE CALIFORNIA PLUMBING CODE FOR HEALTH CARE FACILITIES. RESIDENTIAL OCCUPANCIES ARE EXEMPT FROM TEMPERATURE CONTROL
REQUIREMENTS.
110.3 (b) EFFICIENCY
EQUIPMENT SHALL MEET THE APPLICABLE REQUIREMENTS OF THE APPLIANCE EFFICIENCY REGULATIONS AS REQUIRED BY 110.1.
110.3 (c) 1 OUTLET TEMPERATURE CONTROLS
ON SYSTEMS THAT HAVE A TOTAL CAPACITY GREATER THAN 167,000 BTU/HR, OUTLETS THAT REQUIRE HIGHER THAN SERVICE WATER TEMPERATURES AS LISTED IN
THE ASHRAE HANDBOOK, APPLICATIONS VOLUME, SHALL HAVE SEPARATE REMOTE HEATERS, HEAT EXCHANGERS, OR BOOSTERS TO SUPPLY THE OUTLET WITH THE
HIGHER TEMPERATURE.
110.3 (c) 2 CONTROLS FOR HOT WATER DISTRIBUTION SYSTEMS
SERVICE HOT WATER SYSTEMS WITH CIRCULATING PUMPS OR WITH ELECTRICAL HEAT TRACE SYSTEMS SHALL BE CAPABLE OF AUTOMATICALLY TURNING OFF THE
SYSTEM.
110.3 (c) 3 INSULATION
UNFIRED WATER HEATER STORAGE TANKS AND BACKUP TANKS FOR SOLAR WATER - HEATING SYSTEMS SHALL HAVE:
A. EXTERNAL INSULATION WITH AN INSTALLED R-VALUE >= R-3.5; OR
B. INTERNAL AND EXTERNAL INSULATION WITH A COMBINED R-VALUE >= R-16; OR
C. THE HEAT LOSS OF THE TANK SURFACE BASED ON AN 80°F WATER-AIR TEMPERATURE DIFFERENCE SHALL BE < 6.5 BTU/HR/FT2.
110.3 (c) 6 ISOLATION VALVES
INSTANTANEOUS WATER HEATERS WITH AN INPUT RATING > 6.8KBTU/HR (2KW) SHALL HAVE ISOLATION VALVES ON BOTH COLD WATER SUPPLY AND HOT WATER
PIPE LEAVING THE WATER HEATER, AND HOSE-BIBS OR OTHER FITTINGS ONE ACH VALVE FOR FLUSHING THE WATER HEATER WHEN THE VALVES ARE CLOSED.
110.8 (a) INSULATION CERTIFICATION
INSTALLED INSULATION SHALL BE CERTIFIED BY THE DEPARTMENT OF CONSUMER AFFAIRS PER TITLE 24, PART12, CHAPTERS 12-13, ARTICLE 3" STANDARDS FOR
INSULATING MATERIAL."
110.8 (b) UREA FORMALDEHYDE INSULATION
UREA FORMALDEHYDE INSULATION SHALL NOT BE INSTALLED UNLESS IN EXTERIOR SIDE WALLS WITH A FOUR-MIL-THICK PLASTIC POLYETHYLENE VAPOR RETARDER
OR EQUIVALENT PLASTIC SHEATHING VAPOR RETARDER IS INSTALLED BETWEEN THE UREA FORMALDEHYDE FOAM INSULATION AND THE INTERIOR SPACE.
110.8 (c) INSULATING MATERIAL
ALL INSULATING MATERIALS SHALL BE INSTALLED IN COMPLIANCE WITH THE FLAMESPREAD RATING AND SMOKE DENSITY REQUIREMENTS OF THE CALIFORNIA
BUILDING CODE.
Service Water Heating Mandatory Measures:
2025 CALIFORNIA PLUMBING CODE (CPC)PART 3, TITLE 24, CALIFORNIA CODE
OF REGULATIONS (CCR)
2025 CALIFORNIA ADMINISTRATIVE CODE (CAC)PART 1, TITLE 24, CALIFORNIA
CODE OF REGULATIONS (CCR)
2025 CALIFORNIA BUILDING CODE (CBC)PART 2, TITLE 24, CALIFORNIA
CODE OF REGULATIONS (CCR)
2025 CALIFORNIA ENERGY CODE (CEC)PART 6, TITLE 24, CALIFORNIA CODE
OF REGULATIONS (CCR)
2025 CALIFORNIA FIRE CODE (CFC)PART 9, TITLE 24, CALIFORNIA CODE
OF REGULATIONS (CCR)
2025 CALIFORNIA GREEN BUILDING CODE (CGBC)PART 11, TITLE 24, CALIFORNIA CODE
OF REGULATIONS (CCR)
LOCAL COUNTY ENVIRONMENTAL HEALTH
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATE OF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
3/
9
/
2
0
2
6
4
:
2
5
:
0
9
P
M
P-001
PLUMBING COVER SHEET
2510
Au
t
h
o
r
PIPE MATERIAL SCHEDULE
PLUMBING GENERAL NOTES
PLUMBING LEGENDPIPING SIZING SCHEDULE
ANCHORAGE AND CORING
WATER PIPE SIZING CALCULATION
PIPING MATERIAL NOTES FIXTURE FLOW REQUIREMENT
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 03/09/2026
PLUMBING SCOPE OF WORK
SHEET # SHEET NAME
5 - PLUMBING
P-001 PLUMBING COVER SHEET
P-200 PLUMBING PLANS
P-500 PLUMBING DETAILS
P-700 PLUMBING CUTSHEETS
P-701 PLUMBING CUTSHEETS
P-800 TITLE 24 COMPLIANCE
TOTAL: 6
2APPLICABLE PLUMBING CODE
3 4
1/2" Ø
1/2" Ø
1/2" Ø
3/4" Ø
3/4" Ø
1/2" Ø
1/2" Ø
FLOOR DRAIN, TYP.
SEE DETAIL /4 P-500
FLOOR SINK, TYP.
SEE DETAIL /3 P-500
3/4" Ø
DRAIN IN
MOP SINK
1/2"Ø
P1
(E) UTILITY METER,
SEE PHOTO ON P-200
(E) BOLLARD TO REMAIN
3 4
3/4"Ø
3/4" Ø
CW
SEE MECHANICAL FOR
CUTSHEET INFORMATION
8
P-500
2
P-500
8
P-500
5
P-500
WALL CLEANOUT
1
2
3
4
5
6
10
8
1410
9
(E) 3" WATER
P.O.C.
1/2"Ø
3/8"Ø
TP
ICE
0.5FU
FD
2.5FU
FD
2.5FU
DW
4FU
LAV
2FU
HS
2FU
HS
2FU
MOP
2FU
REF
0.5FU
SNK
2.5FU
SNK
2.5FU
WC
5FU
1/2"Ø
1/2"Ø
TANKLESS WATER
HEATER IN ROOF WELL
ABOVE - SEE P-700
FOR SPECIFICATIONS
(E) KITCHEN
DRAIN LINE2"Ø
4"Ø
(E) DRAIN LINE.
CONNECT TO
GGI -V.I.F.
2"Ø
(E) 3" SEWER
LINE -V.I.F.
REF
0.5FU
11
CONDENSATION FROM
WATER HEATER TO DRIP
INTO DRAINAGE LINE OF
THE MOP SINK BENEATH
CHECK
VALVE
12
1
1
1
FS
2.5FU
FS
2.5FU
SEE ARCHITECTURAL
FOR THE ROOF WELL
7
13
F C/O
INDIRECT CONDENSATION
DRAIN FOR 9
INDIRECT CONDENSATION
DRAIN FOR 2
INDIRECT CONDENSATION
DRAIN FOR 11
INDIRECT CONDENSATION
DRAIN FOR 3
FS
2.5FU
FS
2.5FU
1. FOR NEW POST INSTALLED ANCHORAGE (E.G. MECHANICAL OR CHEMICAL ANCHORAGES, ETC.)
INTO EXISTING CONCRETE, FULLY OR PARTIALLY GROUTED CONCRETE MASONRY UNIT, ETC.,
LOCATE AND IDENTIFY ALL EXISTING REINFORCING, PT TENDONS, EMBEDDED CONDUITS, ETC.,
WITHIN THE AREA OF THE NEW ANCHORAGE VIA NON-DESTRUCTIVE METHODS (E.G. GROUND
PENETRATING RADAR (GPR), X-RAY, ETC.), PRIOR TO POST INSTALLATION IN ORDER TO ENSURE
THAT THE NEW ANCHORAGE DOES NOT CUT, DAMAGE, CHIP, OR ADVERSELY IMPACT THE
INTEGRITY OF THE EXISTING STRUCTURAL AND NON-STRUCTURAL ELEMENTS AND COMPONENTS.
AS-BUILT DRAWINGS CAN BE PROVIDED UPON REQUEST.
2. NO CORING OF ANY KIND THROUGH EXISTING STRUCTURAL AND NON-STRUCTURAL ELEMENTS
AND COMPONENTS (E.G. SLABS, BEAMS, COLUMNS, WALLS, ETC.) SHALL OCCUR WITHOUT
APPROVAL FROM SEOR. FOR ALL CORED PENETRATIONS THAT ARE APPROVED BY SEOR, THESE
CORING LOCATIONS MUST BE CLEARLY IDENTIFIED ON THE DRAWINGS AND MARKED IN THE FIELD
DURING CONSTRUCTION WITH DIMENSIONS, SIZE, ETC. LOCATE AND IDENTIFY ALL EXISTING
REINFORCING, PT TENDONS, EMBEDDED CONDUITS, ETC., WITHIN THE AREA OF THE CORED
PENETRATIONS VIA NON-DESTRUCTIVE METHODS, (E.G. X-RAY, ETC.) AT ANY STRUCTURAL AND
NON-STRUCTURAL ELEMENT AND COMPONENT IN ORDER TO AVOID CUTTING, DAMAGING,
CHIPPING, OR ADVERSELY IMPACTING THE INTEGRITY OF THESE EXISTING ELEMENTS AND
COMPONENTS. AS-BUILT DRAWINGS CAN BE PROVIDED UPON REQUEST.
3. ALL POST-INSTALLED ANCHORAGE, FASTENERS, ETC. REQUIRED FOR ATTACHING AND/OR
SECURING BOTH STRUCTURAL AND NON-STRUCTURE ELEMENTS AND COMPONENTS SHALL HAVE
A CURRENT AND VALID PRODUCT TESTING AND ACCEPTANCE DOCUMENT THAT VERIFIES ITS
APPLICABLE USE AND COMPLIANCE WITH THE APPROPRIATE GOVERNING CODES FOR THE
PROJECT (E.G. ICC-ESR, IAPMO, LARR, ECT.)
4. FOR UNIQUE SITUATIONS WHERE THE ABOVE CANNOT BE ACHIEVED, THOSE CONDITIONS MUST
BE BROUGHT UP TO THE OWNER AND SEOR ENGINEERING FOR FURTHER EVALUATION
AND ASSESSMENT.
HWR
(E)W
SOV IN YB
S OR W
S OR W
ABBREVIATION
POC
COTG
GC
CV
SOV
COYB
WCO
(E) G
G
HWR
(E) G
G
FCO
HW
CD
CW
CD
V
SYMBOL
POINT OF CONNECTION
CLEANOUT TO GRADE
WALL CLEANOUT
CLEANOUT IN YARDBOX
SHUT-OFF VALVE IN YARD BOX
CHECK VALVE
SHUT-OFF VALVE
GAS COCK
HOT WATER RETURN
GAS (LOW PRESSURE)
EXISTING GAS
HOT WATER
FLOOR CLEANOUT
EXISTING SOIL OR WASTE
SANITARY VENT
COLD WATER
CONDENSATE DRAIN
SOIL OR WASTE (BELOW GRADE)
DESCRIPTION
SOIL OR WASTE (ABOVE GRADE)
(E) CW (E) CW EXISTING COLD WATER
(E) HW (E) HW EXISTING HOT WATER
(E) HWR (E) HWR EXISTING HOT WATER RETURN
(E) CD (E) CD EXISTING CONDENSATE DRAIN
(E) V (E) V EXISTING VENT
(E) W (E) W EXISTING WASTE
POD POINT OF DISCONNECT
UP UP PIPING
DOWN DOWN PIPING
WHA WATER HAMMER ARESTOR
TP TRAP PRIMER
EQ #QTY EQUIPMENT
NAME
EXISTING /
NEW DESCRIPTION
WASTE
PLUMBING
HOT
WATER
COLD
WATER GAS
FURNISH
/INSTALL
1
2
3
4
5
1
1
1
1
1
6 1
7 1
8 1
REFRIGERANT
/ BTUS
3-BAY HAND AND
DISHWASHING SINK NEW
NEWFREESTANDING ICE
MAKER AND BIN
JANITOR
MOP SINK
DIRECT AND
INDIRECT
OMCAN #43789 3 COMPARTMENT STAINLESS STEEL
COMMERCIAL SINK
ICE-O-MATIC ICEU220K
NEWCOMBINATION GAS
RANGE
DCR60-6B24GM DUKERS COMBINATION 6
BURNER AND GRIDDLE TOP 33,000 BTU
NEWREFRIGERATED S/W
PREP TABLE REFRIGERATION X, XST-48-18-N R290 REFRIGERANT;
3,400 BTU
NEWFRYER W/ THREE
TUBE BURNER
THREE TUBE BURNER
DCF3-NG
NEW2 DOOR FULL HEIGHT
REFRIGERATOR MIGALI C-2FB-HC R290 REFRIGERANT
90,000 BTU
NEWGAS PASTA COOKER 48000 (CE-CN-0022-NG)70,000 BTU; 1/2" GAS
CONNECTION
NEWWALK IN
REFRIGERATOR
AMERIKOOLER SELF-CONTAINED
REFRIGERATION
NEWSTOCK POT
STOVE
MIGALI C-SPS-1-18 COMPETITOR SERIES
STOCK POT STOVE - 2 BURNER
80,000 BTU; 3/4" GAS
CONNECTION
YES YES
YES YES
YES YES
YES
9 1
10 2
SEE
SPECS
YES
NEW STEELTON 24" X 24" X 12" 18 GAUGE 304 STAINLESS
STEEL ONE COMPARTMENT FLOOR MOP SINK
OFCI
OFCI
OFCI
OFCI
OFCI
OFCI
OFCI
OFCI
OFCI
OFCI
REGENCY 49 1/2" 16 GA STAINLESS STEEL ONE
COMPARTMENT COMMERCIAL SINK WITH SS LEGS1 NEWFOOD PREP SINK YES YES- - OFCI
- -- YES
- ---
- -- YES
- -- -
-
- --
-
- -
-
-- --
- --
- --
11
12 SOLVENTUM 5624704 DETAILSNEWWATER FILTRATION
SYSTEM1 OFCI
13 1 NEWFREEZER 2 DOOR
W/ PREP TABLE MIGALI C-U48F-HC R290 REFRIGERANT;
2,080 BTU
2
OFCI
14
-- YES-
-- - OFCI
-
-
-
-
-
-
NEW 3/4″ WATER IN/OUT STANDARD.NAVIEN NPE-240A2 / S2, 199,900 BTU/HR INDIRECTTANKLESS HOT
WATER HEATER
PLUMBING
FIXTURE
WASTE (DRAIN)WATER
QTY.FU
HAND SINK
MOP SINK
3 COMPARTMENT SINK
PREP SINK
TOTAL
2 2 4
WATER LINE:
WASTE LINE:
FU TOTAL FU (GPM)
PER TABLE A103.1. 702.1, CHART A 103.1(2)
1 2 2
23.5
1 2.5 2.5
1 2.5 2.5
(E) 1-1/4" CW BRANCH PER TENANT SPACE
(E) 4" WASTE TO PLAZA SEWER LATERAL
ICE MAKER
REFRIGERATOR
LAVATORY
HOT WATER DEMAND:PROVIDE A COMMERCIAL HOT WATER SYSTEM CONSISTING OF A TWO
TETHERED TANKLESS STORAGE WATER HEATERS (NAVIEN NPE-240A2 UNITS
IN CASCADE) SIZED TO MEET FIRST HOUR DEMAND FOR A 23.5 FIXTURE UNIT
RESTAURANT TO HANDLE CONTINUOUS FLOW AND HIGH TEMPERATURE RISE
REQUIREMENTS. SYSTEM SHALL INCLUDE MIXING VALVE, RECIRCULATION
PUMP, AND CONTROLS TO MAINTAIN SETPOINT AND PREVENT SCALDING AT
FIXTURES. SELECTED EQUIPMENT SIZING CALCULATIONS BASED ON LOCAL
PLUMBING CODE AND ANTICIPATED SIMULTANEOUS DEMANDS. ONE
INDIVIDUAL UNIT CAN PROCESS 11.2 GALLONS PER MINUTE.
SEE P-700 FOR WATER HEATER SPECIFICATIONS
1
2
11
WATER CLOSET
1
1
TOTAL FU (GPM)
0.5
0.5
2
5
0.5
1
2
5
DISHWASHER 1 4 4
2
2
2.5
2.5
0.5
0.5
2
5
4
2.5
4
2
23.5
2.5
2.5
0.5
1
2
5
4
1
DUKERS DCR60-6B24GM COMBO GAS RANGE
DUKERS DCF3-NG DEEP FRYER
EQUIPMENT
EQUIP.
CONNECTION
SIZE
MAX.
TEMP
GAS INPUT
(CFH)
TOTAL
(CFH)
NAVIEN NPE-240A2 TANKLESS WATER HEATER
GAS SUPPLY SYSTEM PER CPC TABLE 1215.2
TOTAL GAS MAX. CAPACITY OF (E) 2Ø AT LOW PRESSURE PROVIDED: 575-CFH
MIN. GAS PIPE SIZE PER CPC TABLE 1215.2:2Ø AT 900-CFH MAX.
PROVIDE GAS LINE SIZE:(1) 2"Ø = 2"Ø
500°F
1
-
1/2"Ø
3/4"Ø 300
90
200
300
90
400
370
NOTES:CONNECTION SIZE SHOWN IN THIS TABLE IS NOT NECESSARILY THE BRANCH PIPE SIZE TO
EQUIPMENT. SEE NATURAL GAS PIPING PLAN FOR PIPE SIZE.
GAS PIPE SIZING
3/4"Ø 2 250
3/4"Ø 1 120
3/4"Ø
WOK RANGE
DUKERS DCSPA1 STOCK POT RANGE
OMCAN CE-CN-0022-NG PASTA COOKER
QTY.
1
1
2
1
2
703/4"Ø 210°F 701
240
TOTAL BTU/HR:
TOTAL CFH NATURAL GAS:
899,900 BTU/HR MAX.
900 CFH MAX.
WASTE AND WATER FIXTURE UNIT CALC
GAS DEMAND CALCULATION
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATE OF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
3/
9
/
2
0
2
6
4
:
2
5
:
1
1
P
M
P-200
PLUMBING PLANS
2510
Au
t
h
o
r
1/4" = 1'-0"GAS LINE - FLOOR PLAN 2 1/4" = 1'-0"PLUMBING FLOOR PLAN 1
ANCHORAGE AND CORING
PLUMBING LEGEND
PLUMBING FIXTURE SCHEDULE
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
1 PLAN RESUBMITTAL 01/16/2026
B HEALTH SUB 2 02/04/2026
C HEALTH SUB 3 02/25/2026
2 PLAN RESUBMITTAL 03/09/2026
(E) CONCRETE,
SLAB ON GRADE
#4 X 24" LG.
@16" O.C.
CONCRETE SLAB ON GRADE
TO MATCHING EXISTING
SUBGRADE
HILTI HIT RE 500 V3
TYP. (ICC ESR-3814)
EQ
E
Q
SAW CUT WIDTH0' - 4"0' - 4"
#4 @ 26" O.C.
EACH WAY
CONDENSATE DRAINS FROM FOOD STOREROOMS, WALK-IN FREEZERS AND
COOLERS, AND REFRIGERATED EQUIPMENT SHALL HAVE INDIRECT WASTE PIPING
TERMINATING OVER FLOOR SINK WITH P-TRAP AND A MINIMUM OF 1 INCH AIR GAP.
RAISED CURB
(OPTIONAL)
FINISHED FLOOR -
SEE FINISH PLANS
CONCRETE SLAB
FLOOR SINK
P-TRAP
DRAIN PIPERAISED CURB
(OPTIONAL)
1"
M
I
N
.
12"2"2"
2"
6"
12
"
STAINLESS STEEL
CLAMP AND SCREW
(E) OR (N) PIPE PENETRATION,
REFER TO PLUMBING
DRAWINGS
SINGLE PLY CAULKING
SLOP TO SHED WATER
SINGLE PLY SEALING
MASTIC
SEAL TO PENETRATION
WITH COMPATIBLE MASTIC
ALL AROUND
12
"
T
Y
P
.
FASTENED COVER
OVER BITUMEN
UNDER LAYER
SINGLE PLY ROOF MEMBRANE
ADHERED WITH MEMBRANE
BOND ADHESIVE
STRETCH SINGLE PLY ROOF
MEMBRANE WITH 1" MIN. TURN-UP
THERMOPLASTIC STORM
COLLAR COUNTER FLASHING,
SECURE WITH SS CLAMP AND
SEAL TOP EDGE
MI
N
.
4"
COMPATIBLE SEALANT OR
WATER CUT-OFF MASTIC
SINGLE PLY
ROOF SYSTEM
(E) PLYWOOD DECK
TO REMAIN,
PROTECT IN PLACE
(E) ROOF SHINGLE
(E) INSULATION
FASTENER AND PLATE
AT 12" O.C. MAX.
24" MIN.
24" MIN.
FAUCET WITH
VACUUM BREAKER
HOT WATER
COLD WATER
BACKFLOW
PREVENTER
PROVIDE COVE
BASE AT TILE
FLOOR AS OCCURS
PER /2 A-500
1
PROVIDE CLEANOUTS IN
TURNS/ENDS OF PIPE. USE
DWV FITTINGS IF SIZE IS
LARGER THAN 1".
SLOPE PIPE AS
MUCH AS
POSSIBLE
TOWARD
DISCHARGE.
DISCHARGE INTO CENTER HOLE
OF GRATE OF FLOOR SINK WITH
AIR GAP SUFFICIENT TO REMOVE
GRATE AND STRAINER. MINIMUM
GAP = TWICE PIPE DIAMETER.
MAKE PIPE MINIMUM ONE SIZE
LARGER THAN EQUIPMENT
CONNECTION, MINIMUM 3/4". USE "M"
OR "L" HARD COPPER UP TO 1" AND
TYPE DWV FOR LARGER.
ROUTE PIPE INCONSPICUOUSLY AND UNOBTRUSIVELY. HANG PIPE
AS REQUIRED. DO NOT INSULATE INDIRECT DRAIN PIPE WHEN
INSTALLED IN FOOD SERVICE FACILITY. REFER TO LOCAL CODES
FOR FURTHER INFORMATION.
PROVIDE TRAP AND 6" HIGH
PIPE VENT OPEN TO
ATMOSPHERE WHEN DRAIN
LINE IS LONGER THAN 5'
(IAPMO) OR 2' (BOCA).
MAKE CONNECTION TO
EQUIPMENT AS
REQUIRED.
I W
DRIP LINES TO SIT 6" MIN. ABOVE
OFF THE FLOOR AND 1/2" AWAY
FROM WALLS AND NOT CROSS
ANY AISLE, TRAFFIC AREA, OR
DOOR OPENING.
LIQUID WASTE DRAIN LINES SHALL NOT PASS THROUGH AN ICE MACHINE OR ICE STORAGE BIN.
PROVIDE 3/4" ROUGH-IN
AND PROVIDE FULL PORT
BALL SHUT-OFF VALVE
3/4" COLD WATER SUPPLY
DOWN IN PARTITION
WHERE SHOWN ON PLAN
INSTALL WATER FILTERS
PER MANUFACTURERS
INSTRUCTIONS.
FINISHED FLOOR PER
ARCHITECTURAL
ICE BIN
CUBER
(OPTIONAL. SEE
CUTSHEETS AND
SPECIFICATIONS
FOR SELECTED
MODEL
ADAPTERS AND SOFT
COPPER TUBES. SIZE OF
CONNECTION TO (2)
CUBER WATER INLETS.
CONNECT TO CUBERS AND
ICE BIN DRAIN OUTLETS
INDIRECT CONDENSATE
DRAIN LINE. REFER TO
FLOOR SINK DETAIL FOR
INFORMATION
FLOOR SINK PER
PLUMBING PLANSNOTES:
PROVIDE A FLOOR SINK AT SIDE EDGE OF ICE MACHINE, WHERE ACCESSIBLE FOR CLEANING -
CANNOT BE PLACED DIRECTLY UNDERNEATH EQUIPMENT. PROVIDE COLD WATER ROUGH-INSAT
TOP OF ICE MACHINE. ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT CONDITIONS. VERIFY
CONNECTION TYPES PRIOR TO INSTALLATION WITH MANUFACTURER.
3/4"
C/O
FLOOR DRAIN PER
DETAIL
1 1/2" VENT
3" SEWER
3" SEWER
FINISHED WALL
VENT TO ROOF
COLUMN OR
PARTITION AS SHOWN
ON FLOOR PLAN
2"
V
E
N
T
NOTE: VENT NOT
ALLOWED TO BE TIED
TOGETHER UNTIL 6"
ABOVE FLOOR LEVEL RIM.
6"
M
I
N
.
/4 P-500
NOTE*
USE OF DRAIN WITH 6" MINIMUM DEPTH PREVENTS CONCRETE
FROM SURROUNDING WASTE CONNECTION WHEN INSTALLED
ON GRADE AND MAKES FORMING EASIER ABOVE GRADE.
RUBBER SEALANT
WATERTIGHT APPLICATION
6"
CONCRETE SLAB
FINISHED FLOOR -
SEE FINISH PLANS
ANCHOR BOLT,
WASHER AND NUT
ANCHOR CLIP SECURELY
FASTENED TO DRAIN
BODY INTO CONCRETE
SQUARE GRATE
RAISED RIM
1/2" DEEP SQUARE FLANGE
5/
8
"
CONCRETE
FLOOR SLAB FINISHED GRADE
CUT OFF PERRULE
AND SCREW PLUG
PLUG WHERE C.O.
OCCURS AT END OF LINE
CONCRETE BLOCK
FLUSH WITH
FLOOR
SOFT-COLD WATER
SUPPLY TO WATER
HEATER
PIPE UNION, MAKE
DIELECTRIC IF
DISSIMILAR METALS
WELDED STEEL
EXPANSION TANK
WITH POLYPRO-
PYLENE LINING
BUTYL DIAPHRAGM
AIR CHANGING VALVE.
FILL TANK WITH AIR
PRESSURE TO MATCH
WATER PRESSURE,
THEN OPEN VALVE
PIPE HANGER NEXT
TO PIPE TEE
SHUT-OFF VALVE
WATTS NO. 530 1/2"
CALIBRATED
PRESSURE RELIEF
VALVE SET AT 100 PSI
HARD COPPER RELIEF
VALVE INDIRECTLY
DISCHARGE TO FLOOR
MOP SINK AT 2" ABOVE
FLOOD RIM.
UNIT SHALL USE FDA APPROVED COMMERCIAL WATER FOR PUBLIC USE. PIPING
ARRANGEMENTS ARE SHOWN AS A DIAGRAM, ADJUST TO SPECIFIC FIELD
CONDITIONS. VERIFY PIPE SIZES MATCH TANK FITTINGS, FOLLOW
MANUFACTURERS INSTRUCTIONS FOR INSTALLATION PROCEDURE.
1 1/2" SOFT WATER
FROM FILTER
ARRANGEMENT SHOWN IS SCHEMATIC. MAKE FINAL CONNECTION TO
EQUIPMENT AS RECOMMENDED BY MANUFACTURER. PROVIDE W ELDED
FITTINGS AND JOINTS IN ANY CONCEALED, UNSLEEVED LOCATION.
CONFORM TO REQUIREMENTS IN NFPA 54 AND LOCAL CODES AND
JURISDICTION. GAS SYSTEMS TO BE TEST PRESSURE OF NO LESS THAN
1.5 TIMES THE PROPOSED MAXIMUM WORKING PRESSURE (3 PSIG MIN.)
FOR A DURATION OF NO LESS THAN 1 HOUR FOR EACH 500 CUBIC FEET
OF PIPE VOLUME OR FRACTION THEREOF. SEE NFPA 54 FOR FURTHER
TESTING REQUIREMENTS.
ROOF
CEILING
EXHAUST HOOD
SEE MECHANICAL
FLEXIBLE APPLIANCE
CONNECTOR. STUB OUT
WITH MANUAL VALVE
AND CAULK AROUND
GAS PIPE WATERTIGHT
FLOOR
LINE SIZE MANUAL
GAS VALVE (TYP.)
LINE SIZE AUTOMATIC
VALVE FOR EMERGENCY
SHUT-OFF. WIRE TO
HOOD CONTROL PANEL.
TYPICAL 6" DIRT LEG
TO 6" ABOVE FLOOR
G
LOCATE FLOOR DRAIN/FLOOR SINK WHERE SHOWN ON DIMENSIONED ARCHITECTURAL PLAN. IF FLOOR
STRUCTURE INTERFERES WITH FLOOR SINK, MOVE SIDEWAYS IF POSSIBLE, OTHERWISE MOVE BACK.
ALWAYS LOCATE WHERE EASILY ACCESSIBLE, BUT NOT IN FOOT TRAFFIC. IF SITUATION IS FLOOR SLAB
ON GRADE, PROVIDE BACKFILL PER SPECIFICATIONS. IF CONCRETE FLOOR SLAB, SET DRAIN IN PLACE
AND POUR AROUND IT. IF CONCRETE FLOOR IS EXISTING, SAW CUT OR CORE DRILL IT, SET DRAIN BODY
IN PLACE AND POUR AROUND IT. RECESS TOP OF FLOOR SINK 1/2”BELOW FLOOR SURFACE AND SLOPE
FLOOR TO IT. DO NOT RECESS TOP OF FLOOR DRAIN. IF SITUATION IS FLOOR NOT ON GRADE, REFER TO
“FLOOR PENETRATION”DETAIL FOR VENTS.
PROVIDE AN INDIVIDUAL VENT ON ALL FLOOR DRAINS. INSTALL VENT IN PARTITION OR CHASE WHERE
SHOWN ON PLAN. HORIZONTAL VENT BELOW FLOOR IS NOT PERMITTED. IF FLOOR DRAIN/SINK IS
MORE THAN 5’A 2”WASTE OR 6’ON A 3”WASTE FROM THE PARTITION, PROVIDE A TRAP AND WASTE
LINE TWO PIPE SIZES LARGER THAN THE DRAIN/SINK OUTLET, WITH A REDUCER ON THE TRAP INLET,
AND VENT WITHIN 15 FEET. OTHER VENTING METHODS MAY BE USED IF APPROVED BY LOCAL CODE.
PROVIDE TRAP PRIMER
IF REQUIRED BY LOCAL
AUTHORITIES.
MAXIMUM 15’WHERE
ENLARGED WASTE
LINE IS USED AS A
COMBINATION WASTE
AND VENT SYSTEM.
MEMBRANE CLAMPING
COLLAR AND SEEPAGE PAN
MAXIMUM TAILPIECE
LENGTH IS 2 FEET.
SLOPE WASTE
AT 2% MIN. TYP.
MAXIMUM 5’ON 2”
WASTE OR 6’ON 3”.
TRAP
CONCRETE SLAB
ON GRADE
OTHERWISE DEEP-
SEAL P-TRAP.
CONCRETE SLAB
ON GRADE
ORIENTATION OF SINK MAY
VARY PER MANUFACTURER
SINK BOWL CONFIRGURATION
MAY VARY PER MANUFACTURER
THE POT SINK WITH A F/D, THE FIXTURE SHALL BE CONNECTED ON
THE SEWER SIDE OF THE FLOOR DRAIN TRAP PER CPC SECTION 704.3
3"2"2"
2"
2" TRAP
6" F.S.
1 1/2"
1 1/2"
1 1/2"
2 1/2"
CO
2" VTR
TRAP PRIMER INLET
FINISHED FLOOR
30" MAX.30" MAX.
2"
INDIRECT DRAIN LINE PER /13 P-500
1
24" DIA. CAST IRON
FRAME AND
COVER GASKET
COMPACTED FILL OR
UNDISTURBED EARTH
AS REQUIRED
ELEVATION
SECTION
PLAN VIEW COVERS
AND RISERS REMOVED
CONNECTOR SHOWN
WITH PIPE INSTALLED
INSIDE OUTSIDE
PIPE CONNECTOR CAST INTEGRALLY
IN WALL PIPE 0.0. INCHES
4.25" MINIMUM TO 6.25" MAXIMUM
SEE Z-LOCK PIPE CONNECTOR PAGE
FOR ADDITIONAL INFORMATION
2432-03 RISER-3"
2432-06 RISER-6"
2432-12 RISER-12"
24" DIA. SAMPLE BOX WITH
PIPE CONNECTOR
MODEL 2432Z-1
STRAIGHT THROUGH
CONNECTORDIA.
32".
36
.
5
"
M
I
N
.
VA
R
I
A
B
L
E
.
32
"
VARIABLE
PIPE CONNECTOR
(Z-LOCK)
12
"
DIA.
2' - 0"
17
"
SAMPLE BOX WEIGHT: 1,250 LBS.
BOX DESIGN LOAD: H-20 TRAFFIC
SAMPLE BOX MUST BE PLACED ON SUITABLE
BASE OF COMPACTED SOIL OR UNDISTURBED
EARTH IN TRAFFIC CONDITION
FOR COMPLETE DESIGN AND PRODUCT
INFORMATION, CONTACT JENSEN PRECAST.
WALL: FLOOR LEVEL GAS SUPPLY
EQUIPMENT: REAR LOW INLET CONNECTION
RECOMMENDATION: SINGLE SWIVEL KIT INSTALLATION
EG, DORMANT MODEL #1675-SKIT48
FLEXIBLE GAS LINE WITH KEEPER CHAIN
SEDIMENT
TRAP
GAS
CONNECT
EQUIPMENT
PER PLANS
4" MIN.
W/LOCKING
CASTERS
UNDERNEATH
PROVIDE CLEANOUT TEE
WITH SCREWED COUNTER-
SUNK ABS PLASTIC PLUG.
TAPERED THREAD WITH
JOINT COMPOUND
WHERE CLEANOUT TEE IS
CONCEALED IN A CHASE OR
PARTITION, PROVIDE A ROUND 18
GA. STAINLESS STEEL COVER
WITH BEVELED EDGES AND
FLATHEAD MACHINE SCREW.
CONCRETE
SLAB ON GRADE
REFER TO PLUMBING
FIXTURE SCHEDULE
FOR FURTHER
INFORMATION.
COLUMN OR
PARTITION PER
FLOOR PLAN
CLEANOUT FACE
SHALL BE WITHIN
4" OF WALL
SURFACE.
PROVIDE PIPE
EXTENSION IF
REQUIRED.
PROVIDE WCO AT BASE OF ALL RAIN-LEADER
DOWNSPOUTS. PROVIDE WCO WITH A FLOOR CLEANOUT.
LOCATE ABOVE FIXTURE FLOOD RIM WITHIN 4' OF FLOOR.
CONSULT LOCAL CODES FOR OTHER WCO REQUIREMENTS
BTU_OUT = GPM × 500 × ΔT
GPM AT 50 DEG = BTU_OUT / (500 × 50)
NPE-210A2 PUBLISHED: 10.1 GPM @ 35°F.
10.1 × 500 = 5,050.
5,050 × 35 = 176,750 BTU/HR.
GPM AT 50°F = 176,750 ÷ 25,000 = 7.07 GPM.
TWO NPE-210A2 (CASCADE): 7.07 × 2 = 14.14 GPM.
TANKLESS
WATER
HEATER
#1
TANKLESS
WATER
HEATER
#2
PRESSURE
RELEASE
VALVE
UNIONS
BALL VALVES
UNIONS
BALL VALVES
GAS SUPPLY
COLD WATER INLET
UNION
BALL
VALVE
RECIRCULATION
PUMP
CHECK
VALVE
HOT WATER
OUTLETS TO
FIXTURES
SMALL
ELECTRIC
WATER
HEATER
UNION
BALL
VALVE
PRESSURE
RELEASE
VALVE
EXPANSION
TANK
1" = 1'-0"TYP. FLOOR SAWCUT DETAIL 16 1" = 1'-0"TYP. FLOOR SINK 15 1 1/2" =
1'-0"PIPE FLASHING DETAIL 14
1" = 1'-0"MOP SINK DETAIL 5
1" = 1'-0"INDIRECT DRAIN DETAIL 13
1/4" = 1'-0"ICE MACHINE WALL CONNECTION 8
1" = 1'-0"FLOOR DRAIN VENT CONNECT DETAIL 12
1" = 1'-0"FLOOR DRAIN DETAIL, TYP.4
1" = 1'-0"FLOOR CLEANOUT DETAIL TYP.11 1" = 1'-0"EXPANSION TANK PIPE DETAIL 10 1 1/2" =
1'-0"COOKING APPLIANCE GAS DETAIL 9
1" = 1'-0"FLOOR SINK DRAIN DETAIL 3 1/4" = 1'-0"3 COMPARTMENT SINK LINE 2
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATE OF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
3/
9
/
2
0
2
6
4
:
2
5
:
1
2
P
M
P-500
PLUMBING DETAILS
2510
Au
t
h
o
r
1/2" = 1'-0"MULTI WATER HEATER TETHER DIAGRAM 001/4" = 1'-0"SAMPLE BOX DIAGRAM 1
1 1/2" =
1'-0"GAS QUICK DISCONNECT DETAIL 61/4" = 1'-0"WALL CLEANOUT DETAIL, TYP.7
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
1 PLAN RESUBMITTAL 01/16/2026
B HEALTH SUB 2 02/04/2026
C HEALTH SUB 3 02/25/2026
2 PLAN RESUBMITTAL 03/09/2026
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATE OF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
3/
9
/
2
0
2
6
4
:
2
5
:
1
2
P
M
P-700
PLUMBING CUTSHEETS
2510
Au
t
h
o
r
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
1 PLAN RESUBMITTAL 01/16/2026
B HEALTH SUB 2 02/04/2026
C HEALTH SUB 3 02/25/2026
D HEALTH SUB 4 03/06/2026
2 PLAN RESUBMITTAL 03/09/2026
HANDWASHING SINKJANITORIAL FLOOR SINK
WATER FILTRATION SYSTEM
1
FOOD PREP SINK
ICE MAKER
3 COMPARTMENT SINK
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATE OF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
3/
9
/
2
0
2
6
4
:
2
5
:
1
3
P
M
P-701
PLUMBING CUTSHEETS
2510
Au
t
h
o
r
REV DESCRIPTION DATE
C HEALTH SUB 3 02/25/2026
2 PLAN RESUBMITTAL 03/09/2026
PASTA / NOODLE COOKER
FAUCET FOR 3 COMPARTMENT SINK
2 DOOR WORKTOP REFRIGERATOR
FULL HEIGHT 2 DOOR REFRIGERATOR
DEEP FRYER
2 DOOR WORKTOP FREEZER
EMPLOYEE HANDWASHING SINK
LICENSED A RCHITECT
SAMUEL
PIPER
C-39936
RENEWAL
DATE
STATE OF C A LIFORNIA12/31/27
17595 HARVARD AVE, SUITE C
IRVINE, CA. 92614
TEL: 707.815.6742
PROJECT NO.
DRAWN BY
CHECKED BY
APPROVED BY
PROJECT IDENTIFICATION
THE ORIGINAL SIZE OF THIS SHEET IS 30" X 42"
THESE DRAWINGS AND SPECIFICATIONS ARE THE
PROPERTY AND COPYRIGHT OF SANDPIPER ARCHITECTURE
AND SHALL NOT BE USED ON ANY OTHER PROJECT OR
LOCATIONS EXCEPT AS DESCRIBED ON THE DRAWINGS,
WITHOUT WRITTEN AGREEMENT WITH THE ARCHITECT.
STAMP
STAMP
ARCHITECT ON RECORD
CLIENT
SHEET TITLE
SHEET NUMBER
APPROVAL
PL
O
T
D
A
T
E
:
U
S
E
R
:
128 W MACARTHUR BLVD, SANTA ANA,
CA 92707
THE NOODLE LOFT
ISSUE
SP
SP
SANDPIPER
ARCHITECTURE
3/
9
/
2
0
2
6
4
:
2
5
:
1
4
P
M
P-800
TITLE 24 COMPLIANCE
2510
Au
t
h
o
r
REV DESCRIPTION DATE
A UPLOAD 12/02/2026
B HEALTH SUB 2 02/04/2026
2 PLAN RESUBMITTAL 03/09/2026
128 W MacArthur BlvdSanta Ana, CA 92707