Loading...
HomeMy WebLinkAboutHOLD-516 S Ross, Unit C & D - Plan516 S. Ross St. 92701 Conversion of 2 garages within and existing building into a 499 SF and a 477 SF ADUs 2 0 SF0 SF976 SF 976 SF Juan F. Aceytuno, Jr.April 8, 2025 818 317-5762 j.aceytuno.architect@gmail.com ADU C&D City of Santa Ana G-0.1 51 6 S . R O S S S T . S A N T A A N A , C A 9 2 7 0 1 - U N I T C & D JO E M I N H T O & K I M - T H A O T H A N V O La Crescenta, CA 91214 2310 El Moreno St. 818 317-5762 j.aceytuno.architect@gmail.com APPROVAL STAMP SHEET INDEX PROJECT DATAVICINITY MAP ZONING INFORMATION S FLOWER ST MAIN STRE ET S BRI STOL ST S RO SS ST S VAN NE SS AVE W 1ST STREET W BISHOP ST W McFADDEN AVE W CAMILLE ST W WALNUT ST PROJECT SITE W CIVIC CENTER DR PROJECT TEAM OWNER: TITLE 24 ARCHITECT: PROPERTY MANAGER GARAGE CONVERSION TO ADUs BATH EXISTING GARAGE 220 SF EXISTING UTILITY AND D W WH (E) STO (E) STO WH WH (E) PATIO UP STO HALL LIVING KITCHEN BEDROOM 12’−3"x10’−1" 13’−5"x10’−10" 9’−5"x9’−7" LIVING 12’−1"x11’−6" BEDROOM 10’−3"x11’−6" TV TV ADU #C 499 SF PROPOSED DIN. DIN. ADU #D 477 SF PROPOSED (E) PORCH (E) PORCHCOMMON LAUNDRY ROOM SINK Sink Pantry CL O S & P KITCHEN 9’−3"x10’−6" Pantry Ref. Sink D/W SCOPE OF WORK GOVERNING CODES G-0.1 TITLE SHEET - ADU CONVERSION, PROJECT DATA, INDEX, CODE & ZONING DATA, SCOPE OF WORK, VICINITY MAP G-0.2 GENERAL NOTES FOR SINGLE FAMILY DWELLINGS A-1.1 SITE PLAN A-2.1 EXISTING GARAGE & 1ST FLOOR DEMOLITION PLAN A-2.2 NEW ADU FLOOR PLAN, DR. AND WINDOW SCHEDULES A-2.3 EXISTING APTS. 2ND FLOOR AND ROOF PLANS (FOR REFERENCE ONLY - NO WORK PROPOSED) A-3.1 EXISTING EXTERIOR ELEVATIONS A-3.2 PROPOSED EXTERIOR ELEVATIONS A-4.1 ARCHITECTURAL AND FLASHING DETAILS S-1.1 STRUCTURAL CONSTRUCTION NOTES S-2.1 EXISTING FOUNDATION AND 2ND FLOOR FRAMING PLANS S-3.1 EXISTING BUILDING SECTIONS S-4.1 FOUNDATION & FRAMING DETAILS GC-1.1 GREEN BLDG. CODE - MANDATORY MEASURES GC-1.2 GREEN BLDG. CODE - MANDATORY MEASURES T24-C.1 TITLE 24 ENERGY CALCS. - CF1R FORMS - ADU C T24-C.2 TITLE 24 MANDATORY REQ. SUMMARY - ADU C T24-D.1 TITLE 24 ENERGY CALCS. - CF1R FORMS - ADU D T24-D.2 TITLE 24 MANDATORY REQ. SUMMARY - ADU D E-1.1 ELECTRICAL PLAN, NOTES AND LEGEND Ref. D/W Shower NOTE: THE GARAGE CONVERSION TO ADUs FLOOR PLAN IS AS APPROVED BY THE PLANNING DEPARTMENT UNDER THE NEIGHBORHOOD REVIEW PROCESS. APPLICATION #: RES-2024-2565-SCND Range, Micro w/ Exh Fan Range, Micro w/ Exh Fan ABBREVIATIONS alley EX I S T I N G D R I V E W A Y A P R O N 195 SF (NO WORK PROPOSED) (NO WORK PROPOSED) SEPARATE PERMITS CL O S & P BATH HALL ENTRY ENTRY Shower G-0.2 APPROVAL STAMPGENERAL NOTES 51 6 S . R O S S S T . S A N T A A N A , C A 9 2 7 0 1 - U N I T C & D JO E M I N H T O & K I M - T H A O T H A N V O La Crescenta, CA 91214 2310 El Moreno St. 818 317-5762 j.aceytuno.architect@gmail.com PL 140.00’PL BATH 51 4 - 5 1 6 S R O S S S T R E E T BEDROOM KITCHEN LIVINGDINING DEN BEDROOM BEDROOM PORCH BATH (E) 1 STORY RESIDENCE 1,356 SF − 3BED/1BA 514 S. ROSS STREET NO FIRE SPRINKLERS HALL LOT AREA 7,000 SF (E ) D R I V E W A Y A P R O N WH STO STO PATIO UP SITE PLAN - PROPOSED ADUs AND (E) RESIDENCE (E) CLO CLO ENTRY ENTRY ENTRY PL 50.00’ 140.00’PL LIN 50.00’ CONVERT (E) GARAGE AND UNPERMITTED STUDIO INTO A 477 SF ADU #D WH WHSTO CONVERT (E) GARAGE AND UNPERMITTED STUDIO INTO A 499 SF ADU #C (E ) S I D E W A L K (E ) P A R K W A Y A-1.1 51 6 S . R O S S S T . S A N T A A N A , C A 9 2 7 0 1 - U N I T C & D JO E M I N H T O & K I M - T H A O T H A N V O La Crescenta, CA 91214 2310 El Moreno St. 818 317-5762 j.aceytuno.architect@gmail.com APPROVAL STAMP SI T E P L A N CL SINKD W NOTE: NO EXTERIOR SITE WORK IS PROPOSED AL L E Y CL CLO (E) LEGEND AND SYMBOLS WH EXISTING GARAGE & 1ST FLOOR DEMOLITION PLAN A-2.1 51 6 S . R O S S S T . S A N T A A N A , C A 9 2 7 0 1 - U N I T C & D JO E M I N H T O & K I M - T H A O T H A N V O La Crescenta, CA 91214 2310 El Moreno St. 818 317-5762 j.aceytuno.architect@gmail.com (E ) D R I V E W A Y (E) STO (E) STO (E) PATIO UP ENTRY ENTRY APPROVAL STAMP EXISTING GARAGE UNPERMITTED STUDIO EXISTING GARAGE EXISTING GARAGE BATH (E) EXISTING UNPERMITTED STUDIO EXISTING (E) PORCH (E) PORCH LEGEND AND SYMBOLS WH (E) GARAGE DRIVEWAY APRON Shower (E) UTILITY & COMMON LAUNDRY RM. TO REMAIN 220 SF 195 SF (E) D (E) W (E) WH(E) SINK C&D A B (E) WH (E) WH A-2.2 WINDOW SCHEDULE QTYNO. DOOR SCHEDULE TYPESIZE (WxHxT)FRAME MAT.REMARKSDR. MAT. MNFTRQTYNO. LEGEND AND SYMBOLS WINDOW AND DOOR NOTES 51 6 S . R O S S S T . S A N T A A N A , C A 9 2 7 0 1 - U N I T C & D JO E M I N H T O & K I M - T H A O T H A N V O La Crescenta, CA 91214 2310 El Moreno St. 818 317-5762 j.aceytuno.architect@gmail.com FIRST FLOOR PLAN - PROPOSED ADUs C & D APPROVAL STAMP WH BATH (E) STO (E) STO (E) PATIO UP Pantry Ref. STO HALL Shower CL O S & P LIVING BATH KITCHEN Sink BEDROOM 12’−2"x10’−0" HALL 13’−5"x10’−10" 9’−5"x9’−7" ENTRY LIVING 12’−1"x11’−6" BEDROOM 10’−3"x11’−6" ADU #C 499 SF PROPOSED (E) DIN. DIN. ADU #D 477 SF PROPOSED (E) PORCH (E) PORCH ENTRY Pantry CL O S & P Ref. KITCHEN 9’−3"x10’−6" (N ) S h e l v i n g (E) GARAGE DRIVEWAY APRON D/W Shower (E) D (E) W (E) WH WH WH(E) SINK C&D A B EXISTING GARAGE (E) UTILITY & COMMON LAUNDRY RM. TO REMAIN 220 SF 195 SF TYPESIZE (WxH)FRAME MAT.REMARKSGLASSMNFTR Range/Oven Micro W/ 300 CFM Exhaust Over Electric Range/Oven Micro W/ 300 CFM Exhaust Over Electric Sink 24" D/W 18" 24" Wide 24" Wide 18" 24" (E) BEDROOM FLOOR PLAN - EXISTING 2ND FLOOR APARTMENTS (E) BATH DN(E) BEDROOM (E)DINING 12’−0"x11−8" KITCHEN 8’−6"X9’−8" (E) LIVING 8−5"X10’−9" Sink LANDING Ref. Range Pantry 13’−0"x11−0" (E) 13’−0"x9−0" CLOSET CLOSET Linen UNIT B 760 SF (E) APARTMENT UNIT A 760 SF (E) APARTMENT (E) BEDROOM 13’−0"x9−0" (E) BEDROOM 13’−0"x11−0" CLOSET CLOSET HALL HALL Linen (E) DINING 8’−5"x10−9" (E) LIVING 12’−0"X11’−8" Range SinkPantry Ref.KITCHEN 8’−6"X9’−8" (E) (E) BATH DN LANDING Heater ENTRY ENTRY Heater A-2.3 (E ) A P T S - 2 N D F L O O R P L A N & R O O F P L A N 51 6 S . R O S S S T . S A N T A A N A , C A 9 2 7 0 1 - U N I T C & D JO E M I N H T O & K I M - T H A O T H A N V O La Crescenta, CA 91214 2310 El Moreno St. 818 317-5762 j.aceytuno.architect@gmail.com EXISTING ROOF PLAN NO WORK TO BE PERFORMED - FOR REFERENCE ONLY APPROVAL STAMP NO WORK TO BE PERFORMED - FOR REFERENCE ONLY A-3.1 EX I S I S T I N G E X T E R I O R E L E V A T I O N S 51 6 S . R O S S S T . S A N T A A N A , C A 9 2 7 0 1 - U N I T C & D JO E M I N H T O & K I M - T H A O T H A N V O La Crescenta, CA 91214 2310 El Moreno St. 818 317-5762 j.aceytuno.architect@gmail.com EXISTING EAST ELEVATION EXISTING WEST ELEVATIONEXISTING SOUTH ELEVATION EXISTING NORTH ELEVATION APPROVAL STAMPKEY NOTES NOTE: EXTERIOR BUILDING ELEVATIONS IN THIS SHEET ARE OF THE EXISTING BUILDING TO REMAIN. NEW WINDOWS ARE SHOWN IN DASHED LINE RECTANGLES. SEE SHEET A-3.2 FOR PROPOSED ELEVATIONS. WINDOW SCHEDULE QTYNO.TYPESIZE (WxH)FRAME MAT.REMARKSGLASSMNFTR WINDOW NOTES A-3.2 PR O P O S E D E X T E R I O R E L E V A T I O N S 51 6 S . R O S S S T . S A N T A A N A , C A 9 2 7 0 1 - U N I T C & D JO E M I N H T O & K I M - T H A O T H A N V O La Crescenta, CA 91214 2310 El Moreno St. 818 317-5762 j.aceytuno.architect@gmail.com PROPOSED EAST ELEVATION PROPOSED WEST ELEVATIONPROPOSED SOUTH ELEVATION PROPOSED NORTH ELEVATION APPROVAL STAMPKEY NOTESWINDOW NOTES NOTE: EXTERIOR BUILDING ELEVATIONS IN THIS SHEET ARE OF THE EXISTING BUILDING. NEW WINDOWS, GARAGE DOORS AND WINDOW WALL INFILL ARE SHOWN SHADED. SEE SHEET A-3.1 FOR EXISTING BUILDING ELEVATIONS. WINDOW SCHEDULE QTYNO.TYPESIZE (WxH)FRAME MAT.REMARKSGLASSMNFTR 51 6 S . R O S S S T . S A N T A A N A , C A 9 2 7 0 1 - U N I T C & D JO E M I N H T O & K I M - T H A O T H A N V O La Crescenta, CA 91214 2310 El Moreno St. 818 317-5762 j.aceytuno.architect@gmail.com 11 A-4.1 AR C H I T E C T U R A L & F L A S H I N G D E T A I L S NAIL-ON O R RETROFIT WINDOW FRAME INSTALLED PER MFR. REQUIREMENTS CAULK/SEALANT EXTERIOR CEMENT PLASTER OVER METAL LATH AND 2 LAYERS OF BUILDING PAPER SELF-ADHESIVE WATERPROOF FLASHING MEMBRANE PER TYPICAL WINDOW AND LOUVER FLASHING DETAIL R-15 INSULATION SELF-ADHESIVE WATERPROOF FLASHING MEMBRANE PER TYPICAL WINDOW AND LOUVER FLASHING DETAIL EXTERIOR CEMENT PLASTER OVER METAL LATH AND 2 LAYERS OF BUILDING PAPER WOOD STRUCTURAL PANELS WHERE OCCURS 1 5 9 6 2 7 SELF-ADHESIVE, SELF-SEALING 6" WIDE FLEXIBLE FLASHING OVER NAILING FLANGE SELF-ADHESIVE, SELF-SEALING WATERPROOF FLASHING MEMBRANE UNDER SILL NAILING FLANGE AND JAMB FLASHING AND OVER BUILDING PAPER SELF-ADHESIVE, SELF-SEALING 6" WIDE FLEXIBLE FLASHING UNDER NAILING FLANGE AT JAMBS 3 SELF-ADHESIVE WATERPROOF FLASHING MEMBRANE PER TYPICAL WINDOW AND LOUVER FLASHING DETAIL R-15 INSULATION EXTERIOR CEMENT PLASTER OVER METAL LATH AND 2 LAYERS OF BUILDING PAPER 2X4 STUDS @ 16" OC HEADER PER FRAMING PLAN R-15 INSULATION APPROVAL STAMP 5/8" DRYWALL INTERIOR WOOD CASING SELF-ADHESIVE WATERPROOF FLASHING MEMBRANE PER TYPICAL WINDOW AND LOUVER FLASHING DETAIL R-15 INSULATION EXTERIOR CEMENT PLASTER OVER METAL LATH AND 2 LAYERS OF BUILDING PAPER 2X4 STUDS @ 16" OC HEADER PER FRAMING PLAN WOOD STRUCTURAL PANELS WHERE OCCURS 5/8" DRYWALL INTERIOR WOOD CASING CAULK/SEALANT EXTERIOR DOOR PER SCHEDULE (VERIFY DOOR SWING W/ PLANS) SHIM SOLID WOOD FRAME DRIP EDGE METAL 5/8" DRYWALL HEADER PER FRAMING PLAN INTERIOR WOOD CASING INTERIOR WOOD DOOR FRAME 1X APPLIED WOOD STOP INTERIOR WOOD DOOR INTERIOR WOOD CASING NAIL-ON O R RETROFIT WINDOW FRAME INSTALLED PER MFR. REQUIREMENTS CAULK/SEALANT 5/8" DRYWALL NAIL-ON O R RETROFIT WINDOW FRAME INSTALLED PER MFR. REQUIREMENTS INTERIOR WOOD CASING DBL. 2X JAMB FRAMING CORNER METAL CASING EDGE METAL CASING CAULK/SEALANT DBL. 2X SILL FRAMING 5/8" DRYWALL 10 NAILING FLANGE WINDOW - SEE SCHEDULE NOTE: NO GAS FIRED WATER HEATERS ARE ALLOWED IN BEDROOM, BATHROOMS, CLOTHES CLOSET OR ANY SPACE OPENING INTO A BEDROOM OR BATHROOM 4 8 WOOD STRUCTURAL PANELS WHERE OCCURS WOOD STRUCTURAL PANEL WHERE OCCURS 51 6 S . R O S S S T . S A N T A A N A , C A 9 2 7 0 1 - U N I T C & D JO E M I N H T O & K I M - T H A O T H A N V O La Crescenta, CA 91214 2310 El Moreno St. 818 317-5762 j.aceytuno.architect@gmail.com APPROVAL STAMPGENERAL STRUCTURAL NOTES REINFORCING STEEL NOTES WOOD FRAMING GRADE & SPECIES SPECS WOOD FRAMING NOTESFOUNDATION & CONCRETE NOTES ABBREVIATIONS MASONRY AND GROUT NOTES STRUCTURAL STEEL NOTES STRUCTURAL OBSERVATION SPECIAL INSPECTIONS GE N E R A L S T R U C T U R A L N O T E S S-1.1 RETROFIT HD, & ANCHOR BOLTS Rafter to plate 16d (3-1/2" x 0.135") 4-8d (2-1/2" x 0.113") Ceiling joists not attached to parallel rafter, laps over partitions Blocking between joists or rafters to top plate Ceiling joists to plate Roof rafter to ridge, valley or hip rafters: Toe nail Toe nail Face nail Toe nail FLOOR Top or sole plate stud 10d (3" x 0.128") 16d (3-1/2" x 0.135") 2-16d (3-1/2" x 0.135") Double top plates, min. 48 inch offset of end joints Sole plate to joist or blocking Built-up corner studs Built-up header, two pieces with 1/2" spacer Continued header, two pieces Continuous header to stud Ledger strip supporting joists or rafters Top plates, lap at corners and intersections Stud to sole plate Face nail Double studs Double top plates 4-16d (3-1/2" x 0.135") 3-16d (3-1/2" x 0.135") WALL 3-16d (3-1/2" x 0.135") Sole plate to joist or blocking at braced wall panels 3-8d (2-1/2" x 0.113") 3-8d (2-1/2" x 0.113") ROOF CONNECTION FASTENER REMARKS 8-16d (3-1/2" x 0.135") 16d (3-1/2" x 0.135") 3-10d (3" x 0.128") Toe nail 10d (3" x 0.128") 10d (3" x 0.128") 2-16d (3-1/2" x 0.135") 2-10d (3" x 0.128") 24" o.c. 16" o.c. along each edge 16" o.c. along each edge Toe nail Face nail 24" o.c. Nail each layer as follows: 32" o.c. at top and bottom and staggered. Two nails at ends and at each splice. Face nail 24" o.c. Face nail in lapped area Face nail 16" o.c. 16" o.c. Joist to sill or girder Rim joist to top plate (roof application also) 16d (3-1/2" x 0.135") 3-8d (2-1/2" x 0.113") or 2-16d (3-1/2" x 0.135") At each joist or rafter End nail Face nail Toe nail Toe nail Built-up girders and beams, 2-inch lumber layers 3-8d (2-1/2" x 0.113") 8d (2-1/2" x 0.113") 10d (3" x 0.128") Toe nail 6"o.c. FASTENER SCHEDULE Table R602.3(1) SCOPE OF WORK EXISTING GARAGE SPACES TO BE CONVERTED INTO ADU. STRUCTURAL ANALYSIS SHOW THE PROPOSED WINDOW OPENINGS TO COMPLY WITH THE EXCEPTION NOTED IN THE 2022 CALIFORNIA EXISTING BUILDING CODE SECTION 503.4. LOADING 1. GRAVITY LOADS 2. WIND ANALYSIS PER CURRENT EDITION OF ASCE 7 RISK CATEGORY = II BASIC WIND SPEED V = 95 MPH EXPOSURE = B 3. SEISMIC ANALYSIS PER CHAPTER 16 OF THE CURRENT EDITION OF THE CALIFORNIA BUILDING CODE: A. PROCEDURE - EQUIVALENT LATERLA FORCE ANALYSIS B. SYSTEM - LIGHT FRAME (WOOD) WALLS SHEATHED WITH WOOD STRUCTURAL PANELS RATED FOR SHEAR RESISTANCE C. SEISMIC PARAMETERS: DESIGN CATETORY = D SITE CLASS = D I = 1.0 R = 6.5 OMEGA = 3.0 Cd = 4.0 S_s = 1.290 S_1 = 0.460 S_ds = 1.032 S_d1 = 0.860 7 P E R M I T S E T 0 3 . 2 4 . 2 6 MARCH 24, 2026 EXISTING FOUNDATION PLAN S-2.1 51 6 S . R O S S S T . S A N T A A N A , C A 9 2 7 0 1 - U N I T C & D JO E M I N H T O & K I M - T H A O T H A N V O La Crescenta, CA 91214 2310 El Moreno St. 818 317-5762 j.aceytuno.architect@gmail.com APPROVAL STAMP (E) LAUNDRY ROOM EXISTING GARAGE LEGEND AND SYMBOLS EXISTING 2ND FLOOR FRAMING PLAN ADU #C 499 SF PROPOSED ADU #D 477 SF PROPOSED ENTRY ENTRY (E) PORCH (E) PORCH(E) EXISTING ADU #C 499 SF PROPOSED ADU #D 477 SF PROPOSED ENTRY ENTRY GARAGE LAUNDRY ROOM BATH (E) S-3.1 EX I S T I N G B U I L D I N G S E C T I O N S N O T C H I N G D E T . 51 6 S . R O S S S T . S A N T A A N A , C A 9 2 7 0 1 - U N I T C & D JO E M I N H T O & K I M - T H A O T H A N V O La Crescenta, CA 91214 2310 El Moreno St. 818 317-5762 j.aceytuno.architect@gmail.com EXISTING SECTION - B EXISTING SECTION -A APPROVAL STAMP & UTILITY RM.(N) LIVING (N) KITCHEN (N) LIVING (E) KITCHEN (E)KITCHEN (E) DIN/LIV(E) DIN/LIV (E) BEDROOM CLOSET (E) DINING(E) LIVING (N) BEDROOM CLO.BATH (N) LIVING (E) ATTIC KEY NOTES (E) (N)(N) (E) LAUNDRY 1 2 3NOTCHING AND BORING IN DOUBLE TOP PLATE & SILL 4 OPENING WIDTH GREATER THAN STUD SPACINGB L LL EN 'CMST14' w/ 16d NAILS T&B o/ 4x BLKG SHEAR WALL PER PLAN CMST16 W/ 10d NAILS OVER BLKG 3x BLKG W/ A34 EACH END TOP & BOT. 4TYPICAL WALL OPENING DETAIL 5 (E) BLK'G WHERE OCCURS SHEATH & FINISH PER ARCH DRAWINGS, 1/2" MIN STRUCT I SHEATHING w/ 10d EN @ 6" OC (E) BLKG OR BEAM 2x6 JOISTS @ 16" O.C. w/ HU HANGERS EA END 2x6 ALONG PERIMETER w/ 3/8"x3" LONG LAG SCREWS @ 16"O.C. TO (E) BLKG OR JOIST (MIN. 2X6, V.I.F.) A35 CLIP AT EA CORNER MAX. 5'-0"x5'-0" MIN. 2x4 TOP & BOT W/ 3/8"x3" LONG WOOD SCREWS @ 16"O.C. TO (E) BLKG OR HEADER / SILL MIN. 2x4 @ 16"O.C. W/ A34 EACH SIDE / EA END A34 ON 1 SIDE ONLY AT LAST 2x REMAINING OPENING PER ARCH'L ELEVATION SHEATH & FINISH PER ARCH DRAWINGS, MIN 3/8" STRUCT I SHEATHING W/ 10d @ 6"O.C. FO U N D A T I O N A N D F R A M I N G D E T A I L S S-4.1 12 10 34 APPROVAL STAMP 8 11 (N) WALL & CONC CURB AT GARAGE OPENING 9LAP SPLICE AT TOP PLATES 51 6 S . R O S S S T . S A N T A A N A , C A 9 2 7 0 1 - U N I T C & D JO E M I N H T O & K I M - T H A O T H A N V O La Crescenta, CA 91214 2310 El Moreno St. 818 317-5762 j.aceytuno.architect@gmail.com TYPICAL (E) PERIMETER FOOTING & WALL HEADERS WITH TRIMMERS OR HANGERSSTUD WALL CORNER FRAMING PLANS (N) INT. WALL OVER (E) SLABTYP. (E) INT. FOOTING & SEPARATION WALL EXISTING FOUNDATION PLAN S-2.1 51 6 S . R O S S S T . S A N T A A N A , C A 9 2 7 0 1 - U N I T C & D JO E M I N H T O & K I M - T H A O T H A N V O La Crescenta, CA 91214 2310 El Moreno St. 818 317-5762 j.aceytuno.architect@gmail.com APPROVAL STAMP (E) LAUNDRY ROOM EXISTING GARAGE LEGEND AND SYMBOLS EXISTING 2ND FLOOR FRAMING PLAN ADU #C 499 SF PROPOSED ADU #D 477 SF PROPOSED ENTRY ENTRY (E) PORCH (E) PORCH(E) EXISTING ADU #C 499 SF PROPOSED ADU #D 477 SF PROPOSED ENTRY ENTRY GARAGE LAUNDRY ROOM BATH (E) S-3.1 EX I S T I N G B U I L D I N G S E C T I O N S N O T C H I N G D E T . 51 6 S . R O S S S T . S A N T A A N A , C A 9 2 7 0 1 - U N I T C & D JO E M I N H T O & K I M - T H A O T H A N V O La Crescenta, CA 91214 2310 El Moreno St. 818 317-5762 j.aceytuno.architect@gmail.com EXISTING SECTION - B EXISTING SECTION -A APPROVAL STAMP & UTILITY RM.(N) LIVING (N) KITCHEN (N) LIVING (E) KITCHEN (E) KITCHEN (E) DIN/LIV(E) DIN/LIV (E) BEDROOM CLOSET (E) DINING(E) LIVING (N) BEDROOM CLO.BATH (N) LIVING (E) ATTIC KEY NOTES (E) (N)(N) (E) LAUNDRY 1 2 3NOTCHING AND BORING IN DOUBLE TOP PLATE & SILL 4 5 FO U N D A T I O N A N D F R A M I N G D E T A I L S S-4.1 12 10 34 APPROVAL STAMP 8 11 (N) WALL & CONC CURB AT GARAGE OPENING 9LAP SPLICE AT TOP PLATES 51 6 S . R O S S S T . S A N T A A N A , C A 9 2 7 0 1 - U N I T C & D JO E M I N H T O & K I M - T H A O T H A N V O La Crescenta, CA 91214 2310 El Moreno St. 818 317-5762 j.aceytuno.architect@gmail.com TYPICAL (E) PERIMETER FOOTING & WALL HEADERS WITH TRIMMERS OR HANGERSSTUD WALL CORNER FRAMING PLANS (N) INT. WALL OVER (E) SLABTYP. (E) INT. FOOTING & SEPARATION WALL GR E E N B L D G . C O D E M A N D A T O R Y M E A S U R E S GC-1.1 51 6 S . R O S S S T . S A N T A A N A , C A 9 2 7 0 1 - U N I T C & D JO E M I N H T O & K I M - T H A O T H A N V O La Crescenta, CA 91214 2310 El Moreno St. 818 317-5762 j.aceytuno.architect@gmail.com GC-1.2 51 6 S . R O S S S T . S A N T A A N A , C A 9 2 7 0 1 - U N I T C & D JO E M I N H T O & K I M - T H A O T H A N V O La Crescenta, CA 91214 2310 El Moreno St. 818 317-5762 j.aceytuno.architect@gmail.com GR E E N B L D G . C O D E M A N D A T O R Y M E A S U R E S 02/18/2026 SHEET NUMBER DATE ISSUED JOB NO. PROJECT ADDRESS: Sarmen Mirzakhani 7942 Hillrose St. Sunland CA 91040 Phone: 818-419-1831 Calducttesting@gmail.com CERT# CC2021057 TI T L E - 2 4 R E P O R T AN D H E R S R A T I N G - D U C T TE S T I N G S E R V I C E S 516 S ROSS ST (ADU-C), SANTA ANA, CA 92701 Revisions 0 - - 0 - - CA L L : 81 8 - 4 1 9 - 1 8 3 1 F O R C F 2 - R , H E R S & T i t l e 2 4 T 24 -C 1 02/18/2026 SHEET NUMBER DATE ISSUED JOB NO. PROJECT ADDRESS: Sarmen Mirzakhani 7942 Hillrose St. Sunland CA 91040 Phone: 818-419-1831 Calducttesting@gmail.com CERT# CC2021057 TI T L E - 2 4 R E P O R T AN D H E R S R A T I N G - D U C T TE S T I N G S E R V I C E S 516 S ROSS ST (ADU-C), SANTA ANA, CA 92701 Revisions 0 - - 0 - - CA L L : 81 8 - 4 1 9 - 1 8 3 1 F O R C F 2 - R , H E R S & T i t l e 2 4 T 24 -C.2 04/14/2025 SHEET NUMBER DATE ISSUED JOB NO. PROJECT ADDRESS: Sarmen Mirzakhani 7942 Hillrose St. Sunland CA 91040 Phone: 818-419-1831 Calducttesting@gmail.com CERT# CC2021057 TI T L E - 2 4 R E P O R T AN D H E R S R A T I N G - D U C T TE S T I N G S E R V I C E S 516 S ROSS ST (ADU D), SANTA ANA, CA 92701 Revisions 0 - - 0 - - CA L L : 81 8 - 4 1 9 - 1 8 3 1 F O R C F 2 - R , H E R S & T i t l e 2 4 T 24 -D 1 04/14/2025 SHEET NUMBER DATE ISSUED JOB NO. PROJECT ADDRESS: Sarmen Mirzakhani 7942 Hillrose St. Sunland CA 91040 Phone: 818-419-1831 Calducttesting@gmail.com CERT# CC2021057 TI T L E - 2 4 R E P O R T AN D H E R S R A T I N G - D U C T TE S T I N G S E R V I C E S 516 S ROSS ST (ADU D), SANTA ANA, CA 92701 Revisions 0 - - 0 - - CA L L : 81 8 - 4 1 9 - 1 8 3 1 F O R C F 2 - R , H E R S & T i t l e 2 4 T 24 -D.2 E-1.1 51 6 S . R O S S S T . S A N T A A N A , C A 9 2 7 0 1 - U N I T C & D JO E M I N H T O & K I M - T H A O T H A N V O La Crescenta, CA 91214 2310 El Moreno St. 818 317-5762 j.aceytuno.architect@gmail.com ELECTRICAL PLAN FOR PROPOSED ADUs C & D APPROVAL STAMPELECTRICAL NOTES# DESCRIPTIONSYMBOLS ELECTRICAL SYMBOLS/LEGEND W/D BATH EXISTING GARAGE (E) UTILITY & COMMON (E) D (E) W (E) WH (E) STO (E) STO WH WH Pantry Ref. STO HALL CL O S & P LIVINGBATH KITCHEN Sink BEDROOM 12’−3"x10’−1" HALL 13’−5"x10’−10" 9’−5"x9’−7" ENTRY LIVING BEDROOM 10’−3"x11’−6" ADU #C 499 SF PROPOSED (E) DIN. ADU #D 477 SF PROPOSED (E) PORCH (E) PORCH ENTRY LAUNDRY ROOM (E) SINK Pantry CL O S & P Ref. KITCHEN (N ) S h e l v i n g (E) GARAGE DRIVEWAY APRON Sink 24" D/W 18" D/WTO REMAIN 12’−1"x11’−6" 9’−3"x10’−6" WH C&D A B TO REMAIN Range/Oven Micro W/ 300 CFM Exhaust Over Electric Range/Oven Micro W/ 300 CFM Exhaust Over Electric 24" Wide 24" Wide 18" 24" LEGEND AND SYMBOLS DIN. Page 1 Structural Calculations ADU 516 S Ross St Santa Ana, CA 90701 Prepared for: 516 S Ross St Santa Ana, CA 90701 Prepared By Chieh Chieng Assoc. Structural Engineers 5942 Edinger Ave #113-193 Huntington Beach, CA 92649 December, 2025 February, 2026 550 South Hope St, Suite 1700 Los Angeles, CA 90071 915 N. Vicentia new garage 11/25/19 CCN Scope of work: Provide like for like replacement of existing 4 car residential garage. Page 2 TABLE OF CONTENTS Project Description & Loading Criteria _______ Pg 3 Existing Building Code Check ______________ Pg 9 514-516 S Ross St CCN 12/2025 550 South Hope St, Suite 1700 Los Angeles, CA 90071 915 N. Vicentia new garage 11/25/19 CCN Scope of work: Provide like for like replacement of existing 4 car residential garage. Page 3 PROJECT DESCRIPTION & LOADING CRITERIA 514-516 S Ross St CCN 12/2025 550 South Hope St, Suite 1700 Los Angeles, CA 90071 915 N. Vicentia new garage 11/25/19 CCN Scope of work: Provide like for like replacement of existing 4 car residential garage. Page 4 SCOPE OF WORK Conversion of existing garage spaces into ADU LOADING CRITERIA Wind Load Kz = 0.70 (Exposure B, h < 30'-0") Table 26.10-1 Kzt = (1+K1K2K3)2 - flat site use 1.0 Eq. 26.8-1 Kd = 0.85 Table 26.6-1 Ke = 1.0 Table 26.9-1 Wind speed V = 95 mph see ATC Wind Council Maps qh = 0.00256 Kz Kzt Kd Ke V2 = 13.7 psf Eq. 26.10-1 G = 0.85 Sect 26.11.1 Cp = 1.3 G Cpi = -0.18 p = qh (GCp - GCpi) = 17.6 psf (strength level) Eq 27.3-1 Total wind load East-west direction P = p * (158ft2 + 537ft2) / 1000 = 12.2k 514-516 S Ross St CCN 12/2025 550 South Hope St, Suite 1700 Los Angeles, CA 90071 915 N. Vicentia new garage 11/25/19 CCN Scope of work: Provide like for like replacement of existing 4 car residential garage. Page 5 514-516 S Ross St CCN 12/2025 Wall weight Exterior walls {[A_2nd floor] + [A_1st floor]} * w {[9' * (38'+38'+42'+42')] + [8' * (35'+35') + 4' * (42'+42')]} * 10psf = 22k {[A_2nd floor] + [A_1st floor]} * w Interior walls {[9' * (20'+38'+20'+20'+20')] + [4' (35'+35'+20'+20'+20')]} *5psf = 7.9k ASCE Hazards Report Address: 516 S Ross St Santa Ana, California 92701 Standard:ASCE/SEI 7-16 Latitude:33.740109 Risk Category:II Longitude:-117.872565 Soil Class:D - Default (see Section 11.4.3) Elevation:95.85753194539367 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Fri Dec 26 2025 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Page 1 of 3https://ascehazardtool.org/Fri Dec 26 2025 Page 6 SS : 1.29 S1 : 0.46 F a : 1.2 F v : N/A SMS : 1.548 SM1 : N/A SDS : 1.032 SD1 : N/A T L : 8 PGA : 0.546 PGA M : 0.655 F PGA : 1.2 Ie : 1 C v : 1.358 Seismic Site Soil Class: Results: Data Accessed: Date Source: D - Default (see Section 11.4.3) USGS Seismic Design Maps Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Fri Dec 26 2025 Page 2 of 3https://ascehazardtool.org/Fri Dec 26 2025 Page 7 The ASCE Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE Hazard Tool. Page 3 of 3https://ascehazardtool.org/Fri Dec 26 2025 Page 8 550 South Hope St, Suite 1700 Los Angeles, CA 90071 915 N. Vicentia new garage 11/25/19 CCN Scope of work: Provide like for like replacement of existing 4 car residential garage. Page 9 EXISTING BUILDING CODE CHECK 514-516 S Ross St CCN 12/2025 550 South Hope St, Suite 1700 Los Angeles, CA 90071 915 N. Vicentia new garage 11/25/19 CCN Scope of work: Provide like for like replacement of existing 4 car residential garage. Page 10 514-516 S Ross St CCN 12/2025 EXISTING WALL CHECK The following analysis and design check will be for the two walls (north wall 1st floor and south wall 1st floor). The north wall will have only 1 new window. The south wall will have no new windows. NORTH WALL SOUTH WALL BATH EXISTING GARAGE (E) UTILITY & COMMON (E) D (E) W (E) WH (E) STO (E) STO WH WH Pantry Ref. STO HALL CL O S & P LIVINGBATH KITCHEN Sink BEDROOM12’−3"x10’−1" HALL 13’−5"x10’−10" 9’−5"x9’−7" ENTRY LIVING BEDROOM 10’−3"x11’−6"ADU #C 499 SF PROPOSED (E) DIN. ADU #D 477 SF PROPOSED (E) PORCH (E) PORCH ENTRY LAUNDRY ROOM (E) SINK Pantry CL O S & P Ref. KITCHEN (N ) S h e l v i n g (E) GARAGE DRIVEWAY APRON Sink 24" D/W 18" D/WTO REMAIN 12’−1"x11’−6" 9’−3"x10’−6" C&D A B TO REMAIN Range/Oven Micro W/ 300CFM Exhaust Over Electric Range/Oven Micro W/ 300CFM Exhaust Over Electric 24" Wide 24" Wide 18" 24"DIN. 550 South Hope St, Suite 1700 Los Angeles, CA 90071 915 N. Vicentia new garage 11/25/19 CCN Scope of work: Provide like for like replacement of existing 4 car residential garage. Page 11 514-516 S Ross St CCN 12/2025 North wall Vb = 12.9k / 1.4 = 9.2k V to each wall = Vb / 2 = 4.6k W = 12.2k / 1.4 = 8.7k W to each wall = W / 2 = 4.35k Existing lnorth wall = 35'-0" vnorth wall = V / lnorth wall = 131plf vn = 370plf (see following page for capacities) dcrexisting seismic = vnorth wall / vn = 0.36 << 1.0 wnorth wall = W / lnorth wall = 124.3plf vn = 520plf (see following page for capacities) dcrexisting wind = wnorth wall / vn = 0.24 << 1.0 Proposed lnorth wall = 35'-0" - 2'-6" = 32'-6" vnorth wall = V / lnorth wall = 141plf vn = 370plf dcrproposed seismic = vnorth wall / vn = 0.38 << 1.0 wnorth wall = W / lnorth wall = 133plf vn = 520plf (see following page for capacities) dcrexisting wind = wnorth wall / vn = 0.25 << 1.0 Compare demand capacity ratios (dcr) Seismic dcrproposed / dcrexisting = 1.05 Wind dcrproposed / dcrexisting = 1.04 The proposed demand-capacity ratio with the alteration is NOT more than 10 percent greater than its demand-capacity ratio with the alteration ignored. Per 503.4 it is permitted to remain unaltered. In addition the actual demand capacity ratios are very low. permitted. [BS] 503.4 Existing structural elements carrying lateral load. Except as permitted by Section 503.13, where the alter- ation increases design lateral loads, results in a prohibited structural irregularity as defined in ASCE 7, or decreases the capacity of any existing lateral load-carrying structural element, the structure of the altered building or structure shall meet the requirements of Sections 1609 and 1613 of the Cali- fornia Building Code. Reduced seismic forces shall be permitted. Exceptions: 1. Any existing lateral load-carrying structural element whose demand-capacity ratio with the alteration considered is not more than 10 percent greater than its demand-capacity ratio with the alteration ignored shall be permitted to remain unaltered. For purposes of calculating demand-capacity ratios, the demand shall consider applicable load combinations with design lateral loads or forces in accordance with Sections 1609 and 1613 of the California Building Code. Reduced seismic forces shall be permitted. For purposes of this exception, comparisons of demand-capacity ratios and calculation of design lateral loads, forces and capacities shall account for the cumulative effects of additions and alterations since original construction. 550 South Hope St, Suite 1700 Los Angeles, CA 90071 915 N. Vicentia new garage 11/25/19 CCN Scope of work: Provide like for like replacement of existing 4 car residential garage. Page 12 514-516 S Ross St CCN 12/2025 Existing capacities used are clouded based on conservative assumption of existing construction. Same capacities will be used for checking both the existing and proposed wall lengths to keep the demand capacity ratios comparison consistent. 550 South Hope St, Suite 1700 Los Angeles, CA 90071 915 N. Vicentia new garage 11/25/19 CCN Scope of work: Provide like for like replacement of existing 4 car residential garage. Page 13 South wall Proposed scope is to reduce the existing 4'x4' window to 2'x2'. No additional structural analysis required. Reduce existing 4'x4' window to 2'x2' 550 South Hope St, Suite 1700 Los Angeles, CA 90071 915 N. Vicentia new garage 11/25/19 CCN Scope of work: Provide like for like replacement of existing 4 car residential garage. Page 14 514-516 S Ross St CCN 12/2025 2 SCALE: NONE TYP. WALL INFILL DETAIL (E) BLK'G WHERE OCCURS SHEATH & FINISH PER ARCH DRAWINGS, 1/2" MIN STRUCT I SHEATHING w/ 10d EN @ 6" OC (E) BLKG OR BEAM 2x6 JOISTS @ 16" O.C. w/ HU HANGERS EA END 2x6 ALONG PERIMETER w/ 3/8"x3" LONG LAG SCREWS @ 16"O.C. TO (E) BLKG OR JOIST (MIN. 2X6, V.I.F.) A35 CLIP AT EA CORNER MAX. 5'-0"x5'-0" MIN. 2x4 TOP & BOT W/ 3/8"x3" LONG WOOD SCREWS @ 16"O.C. TO (E) BLKG OR HEADER / SILL MIN. 2x4 @ 16"O.C. W/ A34 EACH SIDE / EA END A34 ON 1 SIDE ONLY AT LAST 2x REMAINING OPENING PER ARCH'L ELEVATION SHEATH & FINISH PER ARCH DRAWINGS, MIN 3/8" STRUCT I SHEATHING W/ 10d @ 6"O.C.        !"   #" "$! %&'()*+,-.)&/"012344 55%&'()*+)6,)7+/"89:9525)6,)7+';+<*+/0=>?@ABC=?DE FG'.'*<+H';IJJ&)77/ 4DKKCLAACM>?C>?>M53 %)&-H+77,H;NOOH*)/PCBDQ>?C>?>)&+HOS+R<+<TTO))7J,)+'+R)<;+<;<;HOH)J*R''TH7+&H*+,;J)&%&'UH7H';'OV'U)&;-);+'J)Z&)&)6,H7H+)+'+R)H77,<;*)'O<[,HTJH;N%)&-H+R<U).));&)*)HU)J\.<7)J';+R)<.'U)&)O)&);*)J\+RH7)&+HOH*<+H';H7R)&).S])*,+)J^#AaAbDcdA?CBcA D?KCL=@CPD?BcA e=>LAAAC7+&))+;H+;<\Yghif )7HJ);+H<T **)77'&Sj)TTH;N;H+kl mYYdnALo)7HJ);+H<T**)77'&Sj)TTH;N;H+klO))7<7&)6,H&)JH;+R)<-',;+'O/+)t]mYYs6,<&)''+<N)tl#AaAbDcdA?CBcA D?KCL=@CPD?BcA e=>LAAAC7+&))+;H+;<\Yghif )7HJ);+H<T **)77'&Sj)TTH;N;H+kl mhhgL>@CuVvr\[uw\m\xy "ALdPC =dnALfigfgmfWY)7HJ);+H<T**)77'&Sj)TTH;N;H+klO))7<7&)6,H&)JH;+R)<-',;+'O/+)t]mhhs6,<&)''+<N)tlAAK">P`zAC|D`z!z}}}}32 ">BdA?C#>CAz :~3~3 34+&H*+)Z&)7);+<+HU)<+)/i    !" #$%%&'(%)&$**+&,%-'#.),&!$)#/&0'!$1'$%&2'#$2&%-'!#33.)(#4.'.#567& -#0'#3'!)&2&,$)$%-'2#%'&,3#71'$%&,"(-&&.,''"61)%):#%)&$3#71'$%"&!&%-'!';%!#(%)&$"%&3!&%'"%%-'0#.)2)%7%-'!92#73'!)&2(&11'$('" 3&$" (-3#71'$%&,3'!,&!1#$('&,#$7&%-'!!'= )!'1'$%#"3!&0)2'2)$7" (-3!&%'"%1 "%4')$5!)%)$:#$2!'(')0'247%-'#$%#$#>$),)'2(-&&.)"%!)(%5)%-)$$)$'%78#7"&,%-'2#%'&,%-'(-&&.)"%!)(%'!%),)(#%)&$#4&0'< Page 1 of 1 EXISTING ONE & TWO FAMILY DWELLINGS ELECTRICAL SERVICES UNDERGROUND EXCEPTION CEC 2022 ELC-04 All new utility connections are required to be installed below grade by Santa Ana Municipal Code 41- 626(b). There is a standing exception for one and two family dwellings. This exception applies only when the new electrical service is designed to be fed from below grade as well as overhead. This diagram is a typical unit. The utility is able to feed this cabinet from the top or the bottom without interfering with the distribution wiring. All the circuit breakers and branch circuits are contained in the circuit breaker side of this cabinet. Only listed combination overhead and underground feed service boxes may be used to connect to an overhead utility drop. This exception to an underground fed service applies only to existing single family and two family residences. Planning & Building Agency Permits & Plan Check Section 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 Rigid Conduit Service Entrance Conductor Riser Underground Service Lateral METER Rev. 1/21/2020