HomeMy WebLinkAbout2223 S Rene Dr - REV 1 - Plan(E) VEGETATE LANDSCAPE PROPERTY LINE 55' (E) VEGETATE LANDSCAPE (E ) V E G E T A T E LA N D S C A P E (E ) V E G E T A T E LA N D S C A P E (N) ADDITION TO (N) ADU 798 SQ.FT (E)PATIO COVER 288 SQ.FT (E) SFD 1,630 SQ.FT. 2221 S. Rene Drive PROPERTY LINE 70' ALLEY NO EXISTING EASEMENT ON SITE (E) 5' BLOCK FENCE (E ) 5 ' B L O C K F E N C E (E ) 5 ' B L O C K F E N C E PR O P E R T Y L I N E 1 1 0 ' PR O P E R T Y L I N E 9 5 ' RE N E D R (E ) 5 ' B L O C K FE N C E 36' - 0" 15 ' - 0 " 25' - 6"8' - 6" 70' - 0 1/16" 2' - 9 " 29' - 6"6' - 0"12' - 6"(E ) 5 ' B L O C K FE N C E 5' - 9 " 21 ' - 3 " 61' - 6"8' - 6" 5' - 9 " 21 ' - 3 " 83 ' - 0 3 / 1 6 " 55' - 0" 95 ' - 0 " W SECREST WAY 15' - 0 " (N) PORCH (N) ELECTRIC METER 100 AMP (N) GAS LINE (E) SEWER CONNECTION. MAIN HOUSE (E) GAS METER (E) ELECTRICAL MAIN PANEL (E)WATER METER (N) WATER CONNECTION (E ) M A I N S E W E R L I N E (E ) M A I N S E W E R L I N E (N) SEWER CONNECTION. (N ) M A I N S E W E R L I N E (N ) G A S L I N E (E ) G A S L I N E SLOPE 2% SLOPE 2% SLOPE 5% SL O P E 5 % SL O P E 5 % FIRE SEPARATION LINE FIRE SEPARATION LINE FI R E S E P A R A T I O N L I N E 5' - 0" 3' - 0 " 5' - 0 " 3' - 0 " 10' - 0"38' - 0"21' - 6" DATE: SCALE: Adan MoralesDRAFTER: PERMIT No SH E E T T I L E : DESIGN - PLANNING - PERMIT 7469 Foothill Blvd, Tujunga, CA 91042 Cel: (323) 516-5846 Email: info@arkitpp.com info@arkitpp.com Office Hours Monday - Friday: 8:00am to 6:00 pm THIS DESIGN AND DRAWINGS, ARE COPYRIGHT PROTECTED AND ARE THE EXCLUSIVE PROPERTY OF ARKIT PLANS & PERMIT, THEY SHALL BE NO USED, MODIFIED DUPLICATED IN WHOLE OR IN ANY MANNER, NOR ASSIGNED TO A THIRD PARTY WITHOUT THE WRITTEN AUTHORIZATION OF ARKIT PLANS & PERMIT. 1 REVISIONS SYMB DESCRIPTIONS DATE REVISION OWNER: Gustavo Valencia / Yannet Leal ADDRESS: 2223 S Rene Dr, Santa Ana, CA 92704 PROPOSED FOR: PROJECT MANAGEMENT:Rafael Estevez AS SHOWN N Approval stamp FEB 5 2026 NE W A D U 7 9 8 S Q . F T . AD.1 CO V E R S H E E T LOT: 7,650 SQ. FT. (E) SFD 1,630 SQ.FT. (E) PATIO COVER 450 SQ.FT. (N) ADU 798 SQFT 1,630 + 450 + 798 = TOTAL 2,878 SQ. FT. RFA 37.62 %(35%) N NOTES: A. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE- FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL-BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOKUP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES-WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. B. AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWNSTREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. (PER ORDINANCE 170,158) (SEPARATE PLUMBING PERMIT IS REQUIRED). C. PLUMBING FIXTURES ARE REQUIRED TO BE CONNECTED TO A SANITARY SEWER OR TO AN APPROVED SEWAGE DISPOSAL SYSTEM. R306.3 D. KITCHEN SINKS, LAVATORIES, BATHTUBS, SHOWERS, BIDETS, LAUNDRY TUBS AND WASHING MACHINE OUTLETS SHALL BE PROVIDED WITH HOT AND COLD WATER AND CONNECTED TO AN APPROVED WATER SUPPLY. R306.4 E. BATHTUB AND SHOWER FLOORS, WALLS ABOVE BATHTUBS WITH A SHOWERHEAD, AND SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR. R307.2 F. PROVIDE ULTRA-LOW FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. G. UNIT SKYLIGHTS SHALL BE LABELED BY A LA CITY APPROVED LABELING AGENCY. SUCH LABEL SHALL STATE THE APPROVED LABELING AGENCY NAME, PRODUCT DESIGNATION AND PERFORMANCE GRADE RATING. (RESEARCH REPORT NOT REQUIRED). R308.6.9 H. WATER HEATER MUST BE STRAPPED TO WALL. SEC. 507.3, LAPC I. FOR EXISTING POOL ON SITE, PROVIDE AN ALARM FOR DOORS TO THE DWELLING THAT FORM A PART OF THE POOL ENCLOSURE. THE ALARM SHALL SOUND CONTINUOUSLY FOR A MIN. OF 30 SECONDS WHEN THE DOOR IS OPENED. IT SHALL AUTOMATICALLY RESET AND BE EQUIPPED WITH A MANUAL MEANS TO DEACTIVATE (FOR 15 SECS. MAX.) FOR A SINGLE OPENING. THE DEACTIVATION SWITCH SHALL BE AT LEAST 54" ABOVE THE FLOOR. 6109 OF LABC J. FOR EXISTING POOL ON SITE, PROVIDE ANTI – ENTRAPMENT COVER MEETING THE CURRENT ASTM OR ASME FOR THE SUCTION OUTLETS OF THE SWIMMING POOL, TODDLER POOL AND SPA FOR SINGLE FAMILY DWELLINGS PER ASSEMBLY BILL (AB) NO. 2977. 3162B K. AUTOMATIC GARAGE DOOR OPENERS, IF PROVIDED, SHALL BE LISTED IN ACCORDANCE WITH UL 325. R309.4 L. SMOKE DETECTORS SHALL BE PROVIDED FOR ALL DWELLING UNITS INTENDED FOR HUMAN OCCUPANCY, WHERE A PERMIT IS REQUIRED FOR ALTERATIONS, REPAIRS, OR ADDITIONS. R314.2 M. WHERE A PERMIT IS REQUIRED FOR ALTERATIONS, REPAIRS OR ADDITIONS, EXISTING DWELLINGS OR SLEEPING UNITS THAT HAVE ATTACHED GARAGES OR FUEL-BURNING APPLIANCES SHALL BE PROVIDED WITH A CARBON MONOXIDE ALARM IN ACCORDANCE WITH SECTION R315.2. CARBON MONOXIDE ALARMS SHALL ONLY BE REQUIRED IN THE SPECIFIC DWELLING UNIT OR SLEEPING UNIT FOR WHICH THE PERMIT WAS OBTAINED. R315.2 N. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH NATURAL LIGHT BY MEANS OF EXTERIOR GLAZED OPENINGS IN ACCORDANCE WITH SECTION R303.1 OR SHALL BE PROVIDED WITH ARTIFICIAL LIGHT THAT IS ADEQUATE TO PROVIDE AN AVERAGE ILLUMINATION OF 6 FOOT-CANDLES OVER THE AREA OF THE ROOM AT A HEIGHT OF 30 INCHES ABOVE THE FLOOR LEVEL. R303.1 O. A COPY OF THE EVALUATION REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE AVAILABLE AT THE JOB SITE UNDERGROUND UTILITY INSTALLATIONS PER SAMC SECTION 41-24 . ONLY ONE DROP CONNECTION IS ALLOWED, THE REMAINING CONDUITS NEED TO BE UNDERGROUND SCOPE OF WORK NEW A.D.U. 798 SQ.FT. 1 This project shall comply with the: 2022 California Building Code (CBC) 2022 California Residential Code (CRC) 2022 California Mechanical Code (CMC) 2022 California Plumbing Code (CPC) 2022 California Electrical Code (CEC) 2022 California Green Building Standards Code (CGBS) 2022 California Energy Code 1.LAND USE ZONE: R1 2.CONSTRUCTION TYPE: VB 3.FIRE SPRINKLERS: NONE 4. OCCUPANCY: R3 CODE INFORMATION The property is located at: 2223 S Rene Dr, Santa Ana, CA 92704 - Parking is not required for an Accessory Dwelling in the following instances: - It is located within one-half mile of public transit (any public transit stop along a fixed route with a fixed schedule) - This property is located 0.1 of a mile from : WARNER-RENE Bus stop VICINITY MAP LEGAL DESCRIPTION AIN Lot/Parcel Area (Calculated) ADU ADDRESS ADDRESS Legal description Zoning INDEX ARCHITECTURAL: AD-1 COVER SHEET AD-2 GENERAL NOTES AD-3 EXISTING / PROPOSED FLOOR PLAN & ROOF PLAN AD-4 ELEVATIONS & SECTION PLAN AD-5 FOUNDATION & FRAMING PLAN AD-6 CAL GREEN 1 AD-7 CAL GREEN 2 WF WOOD FRAME PRESCRIPTIVE PROVISIONS TITLE 24: T24-1 ENERGY CALCULATION T24-1 ENERGY CALCULATION 1/8" = 1'-0" 1.1_Plot Plan1 SFD SF: 1,630 ADU SF: 798 798 / 1,630 = .48 TOTAL: .48 ADU/SFD sf ratio (Park & Rec Development Fee) The ADU sf / SFD sf ratio is for Park & Rec fee purpose only. The applicant is responsible for the given “SFR sf” of the existing primary residence; Building Safety staff are not responsible for the accuracy of the given “SFR sf” of the existing residence NOTE: 408-465-09 7,650 (sq ft) 2223 S Rene Dr Santa Ana, CA 92704 2221 S Rene Dr Santa Ana, CA 92704 N TR 2207 LOT 10 R1 Soils report is not necessary as mentioned in Chapter 18, CBC: "The following types of buildings complying with the “Minimum Foundation Construction Requirements” in Section C below are met: c. New detached one-story accessory dwelling units (ADU) with a maximum building area of 750 sq. ft." NOTE: FEMA DESIGNATED FLOOD ZONE No, this project is located in a FEMA Zone X DATE: SCALE: Adan MoralesDRAFTER: PERMIT No SH E E T T I L E : DESIGN - PLANNING - PERMIT 7469 Foothill Blvd, Tujunga, CA 91042 Cel: (323) 516-5846 Email: info@arkitpp.com info@arkitpp.com Office Hours Monday - Friday: 8:00am to 6:00 pm THIS DESIGN AND DRAWINGS, ARE COPYRIGHT PROTECTED AND ARE THE EXCLUSIVE PROPERTY OF ARKIT PLANS & PERMIT, THEY SHALL BE NO USED, MODIFIED DUPLICATED IN WHOLE OR IN ANY MANNER, NOR ASSIGNED TO A THIRD PARTY WITHOUT THE WRITTEN AUTHORIZATION OF ARKIT PLANS & PERMIT. 1 REVISIONS SYMB DESCRIPTIONS DATE REVISION OWNER: Gustavo Valencia / Yannet Leal ADDRESS: 2223 S Rene Dr, Santa Ana, CA 92704 PROPOSED FOR: PROJECT MANAGEMENT:Rafael Estevez AS SHOWN N Approval stamp FEB 5 2026 NE W A D U 7 9 8 S Q . F T . AD.2 GE N E R A L N O T E S GENERAL NOTES 1. THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AND SHALL REPORT ALL DISCREPANCIES TO THE DESIGN CONSULTANTS PRIOR TO COMMENCING WORK. 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE UNIFORM BUILDING CODE, LATEST EDITION AND OR APPLICABLE LOCAL CODES AND REGULATIONS. 3. THE STRUCTURE IS DESIGNED AS A STABLE UNIT AFTER ALL COMPONENTS ARE IN PLACE. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING TEMPORARY BRACING AS REQUIRED TO ENSURE THE VERTICAL AND LATERAL STABILITY OF THE ENTIRE STRUCTURE OR A PORTION THEREOF DURING CONSTRUCTION. 4. PROVIDE OPENINGS AS REQUIRED FOR TYPICAL DETAILS, MECHANICAL AND ELECTRICAL EQUIPMENT, VENTS, DUCTS ETC., INCLUDING THOSE NOT SPECIFICALLY SHOWN ON THE DRAWINGS. 5. GENERAL CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES, INCLUDING ADVISING ALL TRADES OF FEATURES OF CONSTRUCTION, PROVIDING BLOCKS, HOLES, DEPRESSIONS, ETC., AS REQUIRED TO COMPLETE THE JOB. REFER TO DRAWINGS FOR SLAB DEPRESSIONS, SLOPES, CURBS, DRAINS, OPENINGS, ETC. 6. GENERAL CONTRACTOR IS TO BUILD AND MAINTAIN A CONSTRUCTION BARRICADE; [ ALL NECESSARY LIGHTS, SIGN, ETC., IF REQUIRED. ] FOR PROTECTION OF THE PUBLIC AS DIRECTED BY THE LOCAL BUILDING DEPARTMENT. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACEMENT OR REPAIR, WITHOUT CHARGE, FOR ANY DAMAGE CAUSED BY HIM OR HIS SUBCONTRACTORS. 8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO UNDERGROUND UTILITIES ENCOUNTERED IN AREAS WHERE EXCAVATIONS ARE INDICATED AND SHALL REPAIR ANY SUCH DAMAGE AT HIS OWN EXPENSE. WHERE UTILITY LINES MUST BE MAINTAINED UNDER BUILDING, THEY SHALL BE PROPERLY SLEEVED THROUGH FOUNDATION WALLS. FOOTINGS SHALL BE DROPPED TO A DEPTH BELOW UTILITY LINES AS REQUIRED BY DETAILS ON DRAWINGS, i. e. PRESSURE ZONE PROXIMITY, SLEEVE LOCATION, STEPS, REINFORCING, ETC.. ALL AT NO ADDITIONAL COST TO OWNER. 9. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN AND PAY FOR ALL REQUIRED PERMITS PRIOR TO THE START OF CONSTRUCTION. 10. NO STRUCTURAL CHANGES FROM THE APPROVED PLANS SHALL BE MADE IN THE FIELD UNLESS PRIOR TO MAKING SUCH CHANGES, WRITTEN APPROVAL IS OBTAINED. IF CHANGES ARE MADE WITHOUT WRITTEN APPROVAL, SUCH CHANGES SHALL BE THE LEGAL AND FINANCIAL RESPONSIBILITY OF THE CONTRACTOR TO REPLACE OR REPAIR THE CONDITION. 11. ALL CONCRETE AND / OR DECORATIVELY PAVED WALKS SHALL SLOPE AWAY FROM BUILDING, 1/8" PER FOOT OF WIDTH MINIMUM. 12. ALL CONTRACTORS TO PROVIDE LIABILITY INSURANCE AND WORKERS COMPENSATION BENEFITS IN ACCORDANCE WITH STATE LAW FOR ALL WORKERS AND AGENTS WHO WILL BE ON THE SITE AT ANY TIME WHILE PERFORMING WORK ON THIS PROJECT. 13. ALL WORK SHALL BE IN ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL CODES, ORDINANCES AND ANY APPLICABLE AMENDMENTS. 14. CONTRACTOR TO VERIFY LOCATION OF ALL UTILITIES AND SHALL NOTIFY DESIGN CONSULTANTS OF ANY AND ALL DISCREPANCIES PRIOR TO COMMENCING CONSTRUCTION. 15. CONTRACTOR SHALL REPORT ANY DEFECTS, DISCREPANCIES, PROBLEMS OR UNCERTAINTIES TO THE DESIGN CONSULTANTS FOR RESOLUTION PRIOR TO COMMENCING CONSTRUCTION. 16. ALL DEBRIS, EXCESS MATERIAL, ETC., IS TO BE REMOVED BY THE CONTRACTOR BY THE END OF THE JOB. JOB TO BE LEFT SUFFICIENTLY CLEAN AS TO WARRANT OWNERS APPROVAL. 17. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITS, FEES AND INSPECTIONS AS MAY BE REQUIRED FOR COMPLETION OF THE JOB AS PER ALL GOVERNING AGENCIES. 18. ALL WORK TO BE PERFORMED IN ACCORDANCE WITH THE BEST STANDARDS OF EACH PARTICULAR TRADE. 19. CONTRACTOR TO PROVIDE COST ESTIMATE FOR ALL WORK SHOWN ON DRAWINGS AND WORK NORMALLY REQUIRED TO CARRY OUT DESIGN INTENT OF THESE DRAWINGS. 20. INTERIOR CONCRETE SLABS SHALL BE POURED LEVEL ( UNLESS OTHERWISE INDICATED ) 1/8* TOLERANCE ON A 10'-0" EDGE IN ANY GIVEN DIRECTION. 21. ALL DIMENSIONS ARE TO FACE OF STUDS UNLESS NOTED OTHERWISE. 22. DRAWING ARE NOT TO BE SCALED, WORK SHALL BE GOVERNED BY DIMENSION ONLY. DISCREPANCIES BETWEEN THE DRAWINGS AND / OR THE EXISTING SITE CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN CONSULTANTS IMMEDIATELY. 23. ALL GLASS AND GLAZING SHALL COMPLY WITH THE REQUIREMENTS OF THE FEDERAL DESIGN CONSULTANTSURAL GLAZING STANDARDS AND NEW STATE REGULATIONS. 24. ALL BATHROOMS, WATER CLOSET COMPARTMENTS, LAUNDRY ROOMS AND SIMILAR ROOMS SHALL BE PROVIDED WITH NATURAL VENTILATION BY MEANS OF OPEN ABLE EXTERIOR OPENINGS WITH AN AREA OF NOT LESS THAN 1/20 OF THE FLOOR AREA OF THE ROOM ( MINIMUM 1 1/2 SQ. FT. ). APPROVED FAN EXHAUST SYSTEMS, CONNECTED TO THE OUTSIDE, MAY BE SUBSTITUTED FOR NATURAL VENTILATION. THE FAN EXHAUST SYSTEM SHALL BE DESIGN AND OPERATED SO AS TO PROVIDE A COMPLETE CHANGE OF AIR EVERY TWELVE MINUTES. SECURITY PROVISIONS NOTES PROVIDE DETAILS AND SPECIFICATIONS FOR ALL SWINGING DOORS IN SECURITY OPENINGS IN ACCORDANCE WITH THE FOLLOWING REQUIREMENTS: 1. WOOD FLUSH-TYPE DOORS SHALL BE 1 3/8" THICK MINIMUM WITH SOLID CORE CONSTRUCTION OR 2. HOLLOW CORE DOORS LESS THAN 1 3/8" IN THICKNESS COVERED ON THE INSIDE FACE WITH 16 GAUGE SHEET METAL ATTACHED WITH SCREWS AT 6" ON CENTERS AROUND THE PERIMETER OR EQUIVALENT OR 3. WOOD PANEL TYPE DOORS WITH PANELS FABRICATED OF LUMBER NOT LESS THAN 9/16 INCH THICKNESS, PROVIDED SHAPED PORTIONS OF THE PANELS ARE NOT LESS THAN 1/4 INCH NICK. INDIVIDUAL PANELS SHALL NOT EXCEED 300 SQ. FT. IN AREA. STILES AND RAILS SHALL BE OF SOLID LUMBER IN THICKNESS WITH OVERALL DIMENSIONS OF NOT LESS THAN 1 3/8 INCHES IN WIDTH. MULLIONS SHALL BE CONSIDERED A PART OF ADJACENT PANELS, UNLESS SIZED AS REQUIRED HEREIN FOR STILES AND RAILS EXCEPT MUWONS NOT OVER 18 INCHES LONG MAY HAVE AN OVERALL WIDTH OF NOT LESS THAN 2 INCHES. CARVED AREAS SHALL HAVE A THICKNESS OF NOT LESS THAN 3/8 INCHES. 4. GLAZED OPENINGS WITHIN 40" OF THE DOOR LOCK WHEN THE DOOR IS IN THE CLOSED POSITION, SHALL BE FULLY TEMPERED GLASS OR APPROVED BURGLARY RESISTANT MATERIAL, OR SHALL BE PROTECTED BY METAL BARS, SCREENS OR GRILLS HAVING A MAXIMUM OPENING OF 2". THE PROVISIONS OF THIS SECTION SHALL NOT APPLY TO VIEW PORTS OR WINDOWS WHICH DO NOT EXCEED 2¡ IN THEIR GREATEST DIMENSIONS. 91.6720 5. DOOR STOPS OF IN-SWINGING DOORS SHALL BE OF ONE-PIECE CONSTRUCTION WITH THE JAMB OR JOINED BY RABBET TO THE JAMB. 6. ALL PIN-TYPE HINGES WHICH ARE ACCESSIBLE FROM OUTSIDE THE SECURED AREA WHEN THE DOOR IS CLOSED SHALL HAVE NON-REMOVABLE HINGE PINS. IN ADDITION, THEY SHALL HAVE MINIMUM 1/4" DIAMETER STEEL JAMB STUD WITH 1/4" MINIMUM PROTECTION UNLESS THE HINGES ARE SHAPED TO PREVENT REMOVAL OF THE DOOR IF THE HINGE PINS ARE REMOVED. 7. THE STRIKE PLATE FOR LATCHES AND THE HOLDING DEVICE FOR PROTECTING DEADBOLTS IN WOOD CONSTRUCTION SHALL BE SECURED TO THE JAMB AND THE WALL FRAMING WITH SCREWS NOT LESS THAN 2 1/2" IN LENGTH. 91.6711(6) 8. SPECIFY DEADBOLTS WITH HARDENED INSERTS; DEADLOCKING LATCH KEY-OPERATED LOCKS ON EXTERIOR; LOCKS OPEN ABLE WITHOUT KEY, SPECIAL KNOWLEDGE OR SPECIAL EFFORT ON INTERIOR; AND TYPE THROW, AND EMBEDMENT OF DEADBOLTS FOR SINGLE SWINGING DOOR, ACTIVE LEAF OR PAIRS OF DOORS, OR BOTTOM LEAF OF DUTCH DOOR. 9. STRAIGHT DEADBOLTS SHALL HAVE A MINIMUM THROW OF 1" AND AN EMBEDMENT OF NOT LESS THAN 5/8". 91.6711 (8) 10. A HOOK-SHAPED OR AN EXPANDING-LUG DEADBOLT SHALL HAVE A MINIMUM THROW OF 3/4". 91.6711 (8) 11. CYLINDER GUARDS SHALL BE INSTALLED ON CYLINDER LOCKS WHENEVER THE CYLINDER PROTECTS BEYOND THE FACE OF THE DOOR OR IS OTHERWISE ACCESSIBLE TO GRIPPING TOOLS. 91.6711 (F) 12. SHOW MEANS OF SECURING INACTIVE LEAF OF DOUBLE DOOR AND UPPER LEAF OF DUTCH DOOR. 91.6711 (C) 13. SUDING GLASS DOORS AND WINDOWS SHALL BE EQUIPPED WITH LOCKING DEVICES AND SHALL BE SO CONSTRUCTED AND INSTALLED THAT THEY REMAIN INTACT AND ENGAGED WHEN SUBJECTED TO THE TEST SPECIFIED IN 91.6731 AND 91.6732 14. SUDING DOORS AND WINDOWS SHALL BE PROVIDED WITH A DEVICE IN THE UPPER CHANNEL OF THE MOVING PANEL TO PROHIBIT RAISING AND REMOVING OF THE MOVING PANEL IN THE CLOSED OR PARTIALLY OPEN POSITION. 15. LOUVERED WINDOWS SHALL BE PROTECTED BY METAL BARS GRILLS WITH OPENINGS THAT HAVE AT LEAST ONE DIMENSION OF 6" OR LESS, WHICH ARE CONSTRUCTED TO PRECLUDE HUMAN ENTRY. 91.6722 (C) 16. ANY RELEASE FOR METAL BARS, GRILLS, GRATES OR SIMILAR DEVICES CONSTRUCTED TO PRECLUDE HUMAN ENTRY THAT ARE INSTALLED SHALL BE LOCATED ON THE INSIDE OF THE ADJACENT ROOM AND AT LEAST 24 INCHES FROM THE CLOSES OPENING THROUGH SUCH METAL BARS, GRILLS, GRATES OR SIMILAR DEVICES THAT EXCEEDS TWO INCHES IN ANY DIMENSION. 91.6722 (D) 17. IN 8-2, B-4 OCCUPANCIES, PANES OF GLAZING WITH A LEAST DIMENSION GREATER THAN 6" BUT LESS THAN 48" SHALL BE FULLY TEMPERED GLASS OR APPROVED BURGLAR - RESISTANT MATERIAL OR SHALL BE PROTECTED BY METAL BARS OR GRILLS WITH OPENINGS THAT HAVE AT LEAST ONE DIMENSION OF 6" OR LESS. 91.6721 18. OTHER OPEN ABLE WINDOWS SHALL BE PROVIDED WITH SUBSTANTIAL LOCKING DEVICES. IN G OCCUPANCIES, SUCH DEVICES SHALL BE GLIDE BARS, BOLTS, CROSS-BARS, AND/OR PADLOCKS WITH MINIMUM 9/32" HARDENED STEEL SHACKLES AND BOLTED, HARDENED STEEL HASPS. 19. PROVIDE DETAILS AND SPECIFICATIONS FOR THE PROTECTION OF SECURITY OPENINGS OTHER THAN DOORS OR GLAZED OPENINGS PER 91.6723 20. SCREENS, BARRICADES, OR FENCES MADE OF MATERIAL WHICH PRECLUDE HUMAN CLIMBING SHALL BE PROVIDED AT EVERY PORTION OF EVERY ROOF, BALCONY, OR SIMILAR SURFACE WHICH IS WITHIN 8' OF THE UTILITY POLE OR SIMILAR STRUCTURE. ENERGY CONSERVATION STANDARD NOTES 1. THE BUILDING DESIGN MEETS THE REQUIREMENTS OF 'TILE 24, PART 2, CHAPTER 2 - 53. 2. INSULATION INSTALLER SHALL POST IN A CONSPICUOUS LOCATION IN THE BUILDING A CERTIFICATE SIGNED BY THE INSTALLER AND BUILDER STATING THAT THE INSTALLATION CONFORMS WITH THE REQUIREMENTS OF TILE 20, CHAPTER 2, SUBCHAPTER 4, ARTICLE 3. 3. ALL INSULATION MATERIALS SHALL BE CERTIFIED BY THE MANUFACTURER AS COMPLYING WITH THE CALIFORNIA QUALITY STANDARDS FOR INSULATING MATERIAL. 4. DOORS AND WINDOWS BETWEEN CONDITIONED AND OUTSIDE OF UNCONDITIONED SPACES SUCH AS GARAGES AND COMPARTMENTS FOR CENTRAL AIR GAS FURNACES SHALL BE FULLY WEATHER STRIPPED. 5. MANUFACTURED DOORS AND WINDOWS SHALL BE CERTIFIED AND LABELED IN COMPLIANCE WITH THE APPROPRIATE INFILTRATION STANDARDS. 6. CAULK PLUMBING AND ELECTRICAL PENETRATIONS, ALL WINDOW AND DOOR FRAMES, BETWEEN WALL SOLE PLATES AND FLOORS AND ALL OTHER OPENING IN THE ENVELOPE. 7. A NIGHT SETBACK THERMOSTAT SHALL BE INSTALLED. 8. DUCTS SHALL BE CONSTRUCTED, INSTALLED AND INSULATED PER CHAPTER 10 OF 1976 UMC. 9. 25 LUMENS / WATT EFFICIENCY SHALL BE PROVIDED FOR GENERAL LIGHTING IN KITCHENS AND BATHROOMS ( FLUORESCENT LIGHTS ). 10. ALL OPENINGS ( DOORS AND WINDOWS ) SHALL BE PROPERLY WEATHER-STRIPPED, CERTIFIED, AND LABELED. 11. BACK DRAFT DAMPERS FOR ALL EXHAUST AND FAN SYSTEMS SHALL BE PROVIDED. 12. A R-12 EXTERIOR BLANKET SHALL BE PROVIDED FOR HOT WATER HEATER AND SOLAR TANKS. 13. R-3 INSULATION SHALL BE PROVIDED FOR THE FIRST FIVE FEET OF THE WATER HEATER OUTLET PIPE. 14. ALL WATER HEATING AND SPACE CONDITIONING EQUIPMENT, SHOWER HEADS AND FAUCETS SHALL BE C.E.C. CERTIFIED. 15. MASONRY AND FACTORY BUILT FIREPLACES SHALL BE INSTALLED WITH TIGHT FITTING CLOSE ABLE METAL OR GLASS DOORS, OUTSIDE AIR INTAKE WITH DAMPER, AND FLUTE DAMPERS. CONTINUOUS BURNING GAS PILOTS ARE PROHIBITED. 16. ALL STEAM AND STEAM CONDENSATE RETURN PIPING AND ALL CONTINUOUSLY CIRCULATING DOMESTIC HEATING OR HOT WATER PIPING SHALL BE INSULATED AS REQUIRED BY THE PLUMBING DIVISION. ABBREVIATION LIST ABV Above AFF Above Finish Floor AC or Acst Acoustic AC PLAST Acoustical Plaster AC Air conditioner AL or ALUM Aluminum AD Area drain @ At AVG Average BM Beam BLKG Blocking BD Board BR Brass BRZ Bronze BLDG. Building BLTÑIN BuiltÑin CAB Cabinet CB Ceiling CL Center line CM Centimeter CER Ceramic CLR Clear CW Cold water COL Column CONC Concrete CMU Concrete masonry unit CONST Construction CONT Continuous CONIR Contractor DEMO Demolition DIET Detail DIA Diameter DIM Dimension DW Dishwasher DR Door DBL Double DG Double glazed DSG Double strength gloss DF Douglas fir DS Downspout DWR Drawer DWG Drawing DF Drinking fountain EA Each ELEC Electrical EWC Electric water cooler EL or ELEV Elevation EQ Equal EQUIP Equipment EST Estimate EXH Exhaust EXIST Existing EXP JT Expansion joint EXT Exterior FAB Fabricate FOS Face of studs ' or FT Feet FIN Finish FF Finish floor FAO Finish all ove FP Fireproof FG Fix glass FL Floor FD Floor drain FL JT Floor joint FLOUR Fluorescent FTG Footing FAU Forced air unit FRMG Framing FURN Furnish GI Galvanized iron GAR DISP Garbage disposal GEN'L Gloss GR Grade GYP BD Gypsum board HDW Hardware HDWD Hardwood HDR Header HTR Heater HT or HGT Height HC Hollow core HOR or HORIZ Horizontal HW Hot water HR Hour " or IN Inch INSUL Insulation INT Interior JT Joint JÑBOX or JB Junction box LAM Laminated LAV Lavatory LT Light LTG Lighting LTWT Lightweight LIN Linen LINO Linoleum MFG Manufacture MFD Manufactured MRB Marble MAS Masonry MO Masonry opening MR Material MAX Medicine cabinet MECH Mechanical MTL Metal M Meter MIN Minimum MISC Miscellaneous MTD Mounted MULL Mullion NAT Natural NOM Nominal NIC Not in contract # or NO Number OC On center OPG Opening OPP Opposite OS Overflow scupper PTN Partition PLAS Plaste LEGEND PL LAM Plastic laminate PL Plate PLBG Plumbing PLYWD Plywood P/L Property line QTY Quantity QT Quarry tile R Radius REF Reference REFRG Refrigerator REINF Reinforced RMV Remove REQD Required REV Revision R Roof drain RM Room RGH OPNG Schedule SECT Section SHTG Sheothing SH Sheet S & P Shelf and pole SHOW Shower SIM Simular SL Sliding SD Smoke detector SC Solid core SPECS Specifications SQ FT Square feet SQ IN Square inches S ST Stoinless steel STD Standard ST Steel STRL Structural SUSP Suspended SYS System TEL Telephone TEMP Temperature T & G Tongue and groove TC Top of curve TP Top of pavement TR Tread TYP Typical UNF Unfinished UR Urinal VTR Vent through roof VIF Verify in the field VERT Vertical VGDF Vertical grain Douglas fir VTILE Vinyl tile WCT Water closet WH Water heater WP Waterproof WT Weight W Width W / With W / 0 Without WD Wood WI Wrought iron YD Yard (E) Garage door to be removed (E ) W I N D O W T O BE R E M O V E D (E ) D O O R T O B E RE M O V E D (E) Wall to be demo (E) Wall to be demo (E ) W a l l t o b e d e m o (E ) W a l l t o b e d e m o 8' - 0" 2' - 0 " 10 ' - 9 " 11' - 6" 3' - 0" 3' - 0 " 5' - 6" 5 AD.4 130 CFM range hood vented directly to the outside exhaousting.(N) KITCHEN (N) BATHROOM FAN (N) BATHROOMFAN (N) W&D A B C A FAN (N) BEDROOM SD (N) BEDROOM SD (N) LIVING ROOM 15''15'' 24 ' ' 15''15'' 24 ' ' (N) CLOSET (N) CLOSET 5' - 0 " 2' - 0 " 14 ' - 3 " 4' - 0"3' - 0"3' - 0"5' - 6"4' - 0"3' - 11" 13' - 6" 10' - 6"3' - 0" 3' - 0" 2' - 0 " 8' - 0" 3' - 6" 5' - 6 " SD CM 2' - 0 " 3' - 0" 1 22 2 2 3 (N) 22''X30'' ATTIC ACCESS A-A AD.4 A-A AD.4 (N) ELECTRIC METER 100 AMP (N) GAS METER (N) WATER HEATER-WH ENCLOSURE MUST MATCH WITH EXISTING SIDING DRAWING LEGEND NEW WALLS SMOKE DETECTORS CARBON MOXIDE DETECTORS - ENERGY STAR EXHAUST FAN NOTE: -BATHROOM EXHAUST FANS SHALL BE ENERGY STAR COMPLIANT AND CONTROLLED BY HUMIDISTAT 4.506.1 TO BE TERMINATED OUTSIDE OF THE BUILDING MIN 50 CFM FOR FANS CM SD FAN Walls are 6' foot thick with 2''X 6''STUDS every 4'' Provide a min. 26-gage weep screed for stucco at the foundation plate line a minimum of 4-in. above the earth or 2-in above paved areas. NOTE: SMOKE DETECTORS shall be interconnected hard-wired with battery backup and shall be installed in accordance with NFPA 72. EXISTING WALLS DEMO WALLS V A THERMOSTATIC PRESSURE BALANCED VALVE (CPC 408.3) 21 ' - 3 " (N) PORCH 2' - 9 " 6' - 0" 3' - 6 " (N)THRESHOLD 1.25'' ELECTRICAL STOVE ø 36"ø 36" 1-HR FIRE RATEDWALL 5' - 8 " 21 ' - 0 " 3' - 0"19' - 0" (N) HEAT PUMP 46 CFM PER ENERGY CALCS 46 CFM PER ENERGY CALCS 46 CFM PER ENERGY CALCS (N) 1 HOUR FIRE RATED WALL 11' - 0" 11 ' - 3 " 11' - 0" 8' - 2 " 11 ' - 3 " 19 ' - 1 1 " 7' - 6" 16' - 0" 38' - 0" 2' - 8 " 4' - 3 " 4' - 0 " 8' - 4 " 2' - 0 " 4' - 0"4' - 0"6' - 7" 38' - 0" 0' - 4"0' - 4" C A 1' - 0 " 2' - 0" 1' - 0 " 1' - 0" AD U W A L L S P R O J E C T I O N AD U W A L L S P R O J E C T I O N ADU WALLS PROJECTION ADU WALLS PROJECTION EXISTING PATIO COVER SL O P E 3 " / 1 2 " SL O P E 3 " / 1 2 " SL O P E 3 " / 1 2 " SL O P E 3 " / 1 2 " SL O P E 3 " / 1 2 " SL O P E 3 " / 1 2 " A-A AD.4 A-A AD.4 (E) SLOPE 2" / 12"(E) SLOPE 2" / 12" DATE: SCALE: Adan MoralesDRAFTER: PERMIT No SH E E T T I L E : DESIGN - PLANNING - PERMIT 7469 Foothill Blvd, Tujunga, CA 91042 Cel: (323) 516-5846 Email: info@arkitpp.com info@arkitpp.com Office Hours Monday - Friday: 8:00am to 6:00 pm THIS DESIGN AND DRAWINGS, ARE COPYRIGHT PROTECTED AND ARE THE EXCLUSIVE PROPERTY OF ARKIT PLANS & PERMIT, THEY SHALL BE NO USED, MODIFIED DUPLICATED IN WHOLE OR IN ANY MANNER, NOR ASSIGNED TO A THIRD PARTY WITHOUT THE WRITTEN AUTHORIZATION OF ARKIT PLANS & PERMIT. 1 REVISIONS SYMB DESCRIPTIONS DATE REVISION OWNER: Gustavo Valencia / Yannet Leal ADDRESS: 2223 S Rene Dr, Santa Ana, CA 92704 PROPOSED FOR: PROJECT MANAGEMENT:Rafael Estevez AS SHOWN N Approval stamp FEB 5 2026 NE W A D U 7 9 8 S Q . F T . AD.3 EX I S T I N G A N D P R O P O S E D F L O O R PL A N & R O O F P L A N WINDOW SCHEDULE NO.SIZES WIDTH HEIGHT TYPE MATERIAL QUANTITY REMARKS SHDC U-FACTOR A 4'-0''4'-0''VINYL 4 TEMPERED GLAZED SLIDINGB3'-0''3'-0''VINYL 1 TEMPERED GLAZED DOOR SCHEDULE NO.SIZES WIDTH HEIGHT TYPE MATERIAL QUANTITYNo. PANELS 1 4'-0''6'-8''SOLID CORE HINGE23'-0''6'-8''WOOD 4 REMARKS 1- HOLLOW CORE .23 NFRC .3 .23 NFRC .3 - 3 3'-6''6'-8''1- SLIDINGC2'-0''2'-0''VINYL 2 TEMPERED GLAZED .23 NFRC .3 HINGE WOOD WOOD SLIDING FOLDING HOLLOW CORE 1/4" = 1'-0" EXISTING FLOOR PLAN1 1/4" = 1'-0" PROPOSED FLOOR PLAN2 1/4" = 1'-0" ROOF PLAN3 Carbon monoxide detectors are required to be hard wired with battery backup (CRC R315.6). 2. NOTE: ATTIC VENTILATION CALCS: ADU 798 SQ.FT DIVIDED BY 150 = 5.32 5.32 x 144 = 766.08 766.08 SQ. INCHES REQUIRED VENTILATION: AREA (766.08) REQUIRED DIVIDED BY 242 (NET FREE AREA) SQ. INCHES = 3.16 24" X 24" VENT = 242 NET FREE AREA VENTS REQUIRED: 3.16 PROVIDE (3) 24" X 24" SCREENED Louvered door with a minimum of 100 sq.in. is required for door 3 per CMC 504.4.0 3. NOTE: Plans to comply with Energy Code 150.0(s)(t)(u)(v) 4- NOTE: WALL REINFORCEMENT FOR GRAB BARS PER CRC R327.1.1A- DETAIL: Note: The suggested dimensions are to accommodate the minimum required 36-in clearance, center to center, at a water closet; and minimum 24-in clear space in front of water closet. B-DETAIL: ELECTRICAL RECEPTACLES, SWITCH AND DOORBELLS PER CRC R327 Note: Dedicated receptacle outlets; floor receptacle outlets; controls mounted on ceiling fans and ceiling lights and controls located on appliances; and required receptacles on a wall space that has a built-in feature above finish floor less than 15-in. Annular spaces around pipes, electrical cables, conduits or other openings in sole/bottom plates at exterior walls Shall be protected against the passage of rodents by closing such openings with cement mortar, concrete masonry or similar methods. 1. NOTE: 150.0(s) Battery Ready: Mandates a 225-amp main panel, a 1-inch raceway for future installation, space for a transfer switch, and four dedicated branch circuits for essential loads. 150.0(t) Heat Pump Ready: Requires a dedicated 240V, 30-amp (or greater) circuit within 3 feet of a gas furnace, with space in the panel. 150.0(u) Electric Cooktop Ready: Mandates a dedicated 240V, 50-amp circuit near the gas cooktop. 150.0(v) Electric Dryer Ready: Mandates a dedicated 240V, 30-amp circuit near the gas dryer. 1. RECEPTACLES OUTLETS SHALL BE TAMPER RESISTANT. 2. LAUNDRY BRANCH CIRCUITS. AT LEST ONE 20- AMP BRANCH CIRCUITS SHALL BE PROVIDED TO SUPPLY LAUNDRY RECEPTACLE OUTLETS. THIS CIRCUIT SHALL HAVE NO OTHER OUTLETS. 3. A DEDICATED 20-AMP CIRCUITS SHALL BE PROVIDED TO SERVE THE REQUIRED BATHROOM OUTLETS. THIS CIRCUITS CANNOT SUPPLY ANY OTHER OUTLETS (INCLUDING BATHROOM LIGHTING AND FANS). 4. CLOTHES DRYER AND ELECTRICAL RANGER SHALL HAVE AWIRE GROUNDED ELECTRICAL OUTLET. 5. ALL RECESSED LIGHT FIXTURES SHALL BE IC RATED OR FIXTURES NOT IDENTIFIED FOR CONTACT WITH INSULATION SHALL HAVE ALL RECESSED PARTS SPACED AL LEAST 12'' FROM COMBUSTIBLE MATERIALS AND 3'' FROM THERMAL INSULATION. 6. TWO SMALL- APPLIANCE BRANCH CIRCUITS FOR THE KITCHEN LIMITED TO SUPPLYING WALL AND COUNTER OUTLETS ONLY. ADDITIONAL CIRCUITS SHALL BE PROVIDED TO SUPPLY OTHER APPLIANCES, SUCH GARBAGE DISPOSAL, DISH WATER, AND OTHERS. 7. ALL 120 VOLT. SINGLE PHASE. 15 AND 20 -AMP BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOM, OR SIMILAR ROOMS OR AREAS SHALL DE PROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION- TYPE, INSTALLED TO PROVIDED PROTECTION OF BRANCH CIRCUIT. ELECTRICAL NOTES E.G.L. 0' - 0"E.G.L. 0' - 0" (N) CLASS 'A' COMP ICC Evaluation Report ESR-1389 Code: 0668-0055 SHINGLES OVER 13 PAPER ICC Evaluation Report ESR-1389 Code 0668-0055 - CertainTeed Corporation: CertainTeed LAndmark Solaris AGED CEDAR Steep Slope: Asphalt Shingles Orange, Grey, Brown, Multicolor SRI VALUE 28 / 3 YR SOAR REFLECTANCE 0.27 THERMAL EMMITANCE 0.89 ICC Evaluation Report ESR-1389 ASTM D3018 Type I, ASTM D3462 ASTM E108 Fire Resistance: Class A ASTM D3161 Class F Wind Resistance ASTM D7158 Class H Wind Resistance UL 2390/ASTM D6381 Class H Wind Resistance UL 790 Fire Resistance: Class A UL 997 Wind Resistance, NYC-MEA-120-79-M CSA Standard A123.5-98 (&-05) Ontario BMEC Auth. 97-10-219 Miami-Dade Product Control Approved Florida Product Approval # FL5444 Energy Star Rated CA Title 24, Part 6 (Cool Steep Slope Roofing) USGBC LEED®-NC 12 ' - 0 " 0' - 6 " 12 ' - 6 " 3' - 4 9 / 1 6 " 8' - 7 7 / 1 6 " 0' - 6 " 12 ' - 6 " (N) SIDING (N) SIDING (N) WHITE WOOD TRIM (N) WHITE WOOD TRIM 14' - 9" E.G.L. 0' - 0" (N) SIDING E.G.L. 0' - 0" (N) SIDING 0' - 6 " 8' - 7 7 / 1 6 " 3' - 4 9 / 1 6 " 12 ' - 6 " 9' - 1 7 / 1 6 " 3' - 4 9 / 1 6 " 12 ' - 6 " (N) CLASS 'A' COMP ICC Evaluation Report ESR-1389 Code: 0668-0055 SHINGLES OVER 13 PAPER ICC Evaluation Report ESR-1389 Code 0668-0055 - CertainTeed Corporation: CertainTeed LAndmark Solaris AGED CEDAR Steep Slope: Asphalt Shingles Orange, Grey, Brown, Multicolor SRI VALUE 28 / 3 YR SOAR REFLECTANCE 0.27 THERMAL EMMITANCE 0.89 ICC Evaluation Report ESR-1389 ASTM D3018 Type I, ASTM D3462 ASTM E108 Fire Resistance: Class A ASTM D3161 Class F Wind Resistance ASTM D7158 Class H Wind Resistance UL 2390/ASTM D6381 Class H Wind Resistance UL 790 Fire Resistance: Class A UL 997 Wind Resistance, NYC-MEA-120-79-M CSA Standard A123.5-98 (&-05) Ontario BMEC Auth. 97-10-219 Miami-Dade Product Control Approved Florida Product Approval # FL5444 Energy Star Rated CA Title 24, Part 6 (Cool Steep Slope Roofing) USGBC LEED®-NC E.G.L. 0' - 0"E.G.L. 0' - 0" (N) SIDING (N) CLASS 'A' COMP ICC Evaluation Report ESR-1389 Code: 0668-0055 SHINGLES OVER 13 PAPER ICC Evaluation Report ESR-1389 Code 0668-0055 - CertainTeed Corporation: CertainTeed LAndmark Solaris AGED CEDAR Steep Slope: Asphalt Shingles Orange, Grey, Brown, Multicolor SRI VALUE 28 / 3 YR SOAR REFLECTANCE 0.27 THERMAL EMMITANCE 0.89 ICC Evaluation Report ESR-1389 ASTM D3018 Type I, ASTM D3462 ASTM E108 Fire Resistance: Class A ASTM D3161 Class F Wind Resistance ASTM D7158 Class H Wind Resistance UL 2390/ASTM D6381 Class H Wind Resistance UL 790 Fire Resistance: Class A UL 997 Wind Resistance, NYC-MEA-120-79-M CSA Standard A123.5-98 (&-05) Ontario BMEC Auth. 97-10-219 Miami-Dade Product Control Approved Florida Product Approval # FL5444 Energy Star Rated CA Title 24, Part 6 (Cool Steep Slope Roofing) USGBC LEED®-NC 3' - 4 9 / 1 6 " 8' - 7 7 / 1 6 " 0' - 6 " 12 ' - 6 " 3' - 4 9 / 1 6 " 8' - 7 7 / 1 6 " 0' - 6 " (N) CLASS 'A' COMP ICC Evaluation Report ESR-1389 Code: 0668-0055 SHINGLES OVER 13 PAPER ICC Evaluation Report ESR-1389 Code 0668-0055 - CertainTeed Corporation: CertainTeed LAndmark Solaris AGED CEDAR Steep Slope: Asphalt Shingles Orange, Grey, Brown, Multicolor SRI VALUE 28 / 3 YR SOAR REFLECTANCE 0.27 THERMAL EMMITANCE 0.89 E.G.L. 0' - 0"E.G.L. 0' - 0" (N) SIDDING 4' - 0 " 8' - 0 " 0' - 6 " 12 ' - 6 " 4' - 0 " 8' - 0 " 0' - 6 " 12 ' - 6 " (N) ATTIC VENT 24"x24" COVERED W/ CORROSION RESISTANT METAL MESH W/ MAXIMUM MESH OPENINGS OF 1/8" IN DIMENSION 5 AD.4 1/2'' GYP DRYWALL BOARD R15 INSULATION R38 INSULATION 8' - 0 " 1/2'' GYP DRYWALL BOARD R15 INSULATION (N) ATTIC AREA A-A AD.4 (N) ATTIC AREA 1/2'' GYP DRYWALL BOARD R15 INSULATION FIRE RATED WALL DATE: SCALE: Adan MoralesDRAFTER: PERMIT No SH E E T T I L E : DESIGN - PLANNING - PERMIT 7469 Foothill Blvd, Tujunga, CA 91042 Cel: (323) 516-5846 Email: info@arkitpp.com info@arkitpp.com Office Hours Monday - Friday: 8:00am to 6:00 pm THIS DESIGN AND DRAWINGS, ARE COPYRIGHT PROTECTED AND ARE THE EXCLUSIVE PROPERTY OF ARKIT PLANS & PERMIT, THEY SHALL BE NO USED, MODIFIED DUPLICATED IN WHOLE OR IN ANY MANNER, NOR ASSIGNED TO A THIRD PARTY WITHOUT THE WRITTEN AUTHORIZATION OF ARKIT PLANS & PERMIT. 1 REVISIONS SYMB DESCRIPTIONS DATE REVISION OWNER: Gustavo Valencia / Yannet Leal ADDRESS: 2223 S Rene Dr, Santa Ana, CA 92704 PROPOSED FOR: PROJECT MANAGEMENT:Rafael Estevez AS SHOWN N Approval stamp FEB 5 2026 NE W A D U 7 9 8 S Q . F T . AD.4 EL E V A T I O N S & S E C T I O N 1/4" = 1'-0" SOUTH ELEVATION1 1/4" = 1'-0" NORTH ELEVATION2 1/4" = 1'-0" EAST ELEVATION3 1/4" = 1'-0" WEST ELEVATION4 Note: Annular spaces around pipes, electrical cables, conduits or other openings in sole/bottom plates at exterior walls Shall be protected against the passage of rodents by closing such openings with cement mortar, concrete masonry or similar methods. 1/4" = 1'-0" A-A SECTIONA-A 1/4" = 1'-0" B-B SECTION5 NOTE: NEW SIDING TO MATCH WITH EXISTING SIDING . NEW SIDING SPECIFICATIONS: Coverage Area - 3.33 sq ft Product Thickness - .5 in Material - Composite Product Weight - 10.52 lb ICC EVALUATION - ESR-3923 Manufacturer - New Tech Wood ATTIC VENTILATION CALCS: ADU 798 SQ.FT DIVIDED BY 150 = 5.32 5.32 x 144 = 766.08 766.08 SQ. INCHES REQUIRED VENTILATION: AREA (766.08) REQUIRED DIVIDED BY 242 (NET FREE AREA) SQ. INCHES = 3.16 24" X 24" VENT = 242 NET FREE AREA VENTS REQUIRED: 3.16 PROVIDE (4) 24" X 24" SCREENED DATE: SCALE: Rafael EstevezDESIGNER: PERMIT No (N ) A D U 7 9 8 S Q F T . SH E E T T I L E : DESING - PLANNING - PERMIT 7501 CORBIN AVE. WINNETKA, CA, 91306-3003 Cel: (323) 5116-5864 Email: planning Qarkitpp.com Office Hours Monday - Friday: 8:00am to 6:00 pm THIS DESIGN AND DRAWINGS, ARE COPYRIGHT PROTECTED AND ARE THE EXCLUSIVE PROPERTY OF ARKIT PLANS & PERMIT, THEY SHALL BE NO USED, MODIFIED DUPLICATED IN WHOLE OR IN ANY MANNER, NOR ASSIGNED TO A THIRD PARTY WITHOUT THE WRITTEN AUTHORIZATION OF ARKIT PLANS & PERMIT. 1 REVISION SSYM B DESCRIPTION S DAT E REVISIO N OWNE R ADDRES S PROPOSED FOR: 8/13/25 T2 Ti t l e 2 4 DATE: SCALE: Rafael EstevezDESIGNER: PERMIT No (N ) A D U 7 9 8 S Q F T . SH E E T T I L E : DESING - PLANNING - PERMIT 7501 CORBIN AVE. WINNETKA, CA, 91306-3003 Cel: (323) 5116-5864 Email: planning Qarkitpp.com Office Hours Monday - Friday: 8:00am to 6:00 pm THIS DESIGN AND DRAWINGS, ARE COPYRIGHT PROTECTED AND ARE THE EXCLUSIVE PROPERTY OF ARKIT PLANS & PERMIT, THEY SHALL BE NO USED, MODIFIED DUPLICATED IN WHOLE OR IN ANY MANNER, NOR ASSIGNED TO A THIRD PARTY WITHOUT THE WRITTEN AUTHORIZATION OF ARKIT PLANS & PERMIT. 1 REVISION SSYM B DESCRIPTION S DAT E REVISIO N OWNE R ADDRES S PROPOSED FOR: 8/13/25 T2 Ti t l e 2 4 DATE: SCALE: Adan MoralesDRAFTER: PERMIT No SH E E T T I L E : DESIGN - PLANNING - PERMIT 7469 Foothill Blvd, Tujunga, CA 91042 Cel: (323) 516-5846 Email: info@arkitpp.com info@arkitpp.com Office Hours Monday - Friday: 8:00am to 6:00 pm THIS DESIGN AND DRAWINGS, ARE COPYRIGHT PROTECTED AND ARE THE EXCLUSIVE PROPERTY OF ARKIT PLANS & PERMIT, THEY SHALL BE NO USED, MODIFIED DUPLICATED IN WHOLE OR IN ANY MANNER, NOR ASSIGNED TO A THIRD PARTY WITHOUT THE WRITTEN AUTHORIZATION OF ARKIT PLANS & PERMIT. 1 REVISIONS SYMB DESCRIPTIONS DATE REVISION OWNER: Gustavo Valencia / Yannet Leal ADDRESS: 2223 S Rene Dr, Santa Ana, CA 92704 PROPOSED FOR: PROJECT MANAGEMENT:Rafael Estevez AS SHOWN N Approval stamp FEB 5 2026 NE W A D U 7 9 8 S Q . F T . AD.6 CA L G R E E N DATE: SCALE: Adan MoralesDRAFTER: PERMIT No SH E E T T I L E : DESIGN - PLANNING - PERMIT 7469 Foothill Blvd, Tujunga, CA 91042 Cel: (323) 516-5846 Email: info@arkitpp.com info@arkitpp.com Office Hours Monday - Friday: 8:00am to 6:00 pm THIS DESIGN AND DRAWINGS, ARE COPYRIGHT PROTECTED AND ARE THE EXCLUSIVE PROPERTY OF ARKIT PLANS & PERMIT, THEY SHALL BE NO USED, MODIFIED DUPLICATED IN WHOLE OR IN ANY MANNER, NOR ASSIGNED TO A THIRD PARTY WITHOUT THE WRITTEN AUTHORIZATION OF ARKIT PLANS & PERMIT. 1 REVISIONS SYMB DESCRIPTIONS DATE REVISION OWNER: Gustavo Valencia / Yannet Leal ADDRESS: 2223 S Rene Dr, Santa Ana, CA 92704 PROPOSED FOR: PROJECT MANAGEMENT:Rafael Estevez AS SHOWN N Approval stamp FEB 5 2026 NE W A D U 7 9 8 S Q . F T . AD.7 CA L G R E E N 2 (N) 4X6 HDR (N) 4X6 HDR (N) 4X6 HDR (N) 4X6 HDR (N) 4X6 HDR (N) 4X6 HDR (N) 4X6 HDR (N) 4X6 HDR (N) 4X6 HDR (N) 4X6 HDR (N ) 4 X 6 HD R (N ) 4 X 6 HD R 1' - 0 " NE W F O O T I N G 1' - 0 " NEW FOOTING 1' - 0" NE W F O O T I N G 1' - 0 " L= 4 ' HD U 2 1 L=4' HDU2 L=4' HDU2 1 1 22' - 0" L= 4 ' HD U 2 1 L= 4 ' HD U 2 1 L= 4 ' HD U 2 1 17 ' - 0 " L=4' HDU2 L=4' HDU2 1 1 24' - 11" NEW FOOTING 1' - 0" (N) CONCRETE SLAB 4" THICK BASE OF 1/2 " OR LARGER AGGREGATE, A 10 MIL VAPOR BARRIER SHALL BE PROVIDED IN DIRECT CONTACT WITH CONCRETE. THE SLABS SHALL BE AT LEAST 4" THICK AND SHALL BE REINFORCED WITH #4 BARS SPACED AT INTERVALS NO EXCEEDING 16" EACH WAY (N) CONCRETE SLAB 4" THICK BASE OF 1/2 " OR LARGER AGGREGATE, A 10 MIL VAPOR BARRIER SHALL BE PROVIDED IN DIRECT CONTACT WITH CONCRETE. THE SLABS SHALL BE AT LEAST 4" THICK AND SHALL BE REINFORCED WITH #4 BARS SPACED AT INTERVALS NO EXCEEDING 16" EACH WAY NE W F O O T I N G 1' - 0 " NE W F O O T I N G 1' - 0 " NE W F O O T I N G 1' - 0 " L= 1 1 ' - 6 ' ' HD U 4 1 L=4' HDU2 1 L=4' HDU2 1 12' - 0" 9' - 1" (N) CONCRETE SLAB 4" THICK BASE OF 1/2 " OR LARGER AGGREGATE, A 10 MIL VAPOR BARRIER SHALL BE PROVIDED IN DIRECT CONTACT WITH CONCRETE. THE SLABS SHALL BE AT LEAST 4" THICK AND SHALL BE REINFORCED WITH #4 BARS SPACED AT INTERVALS NO EXCEEDING 16" EACH WAY 14 AD.5 14 AD.5 20 AD.5 18 AD.5 17 AD.5 17 AD.5 18 AD.5 EXISTING GARAGE FOOTING (E) 4" CONCRET SLAB Leveling of existing concrete slab where required. Installation of RedGard. Waterproofing and Crack Prevention Membrane. Be provided in the indicated areas, it complies with the required standard ESR-1413 SEE NOTES TO COMPLY WITH WATER RESISTIVE BARRIERS (E) 4" CONCRET SLAB Leveling of existing concrete slab where required. Installation of RedGard. Waterproofing and Crack Prevention Membrane. Be provided in the indicated areas, it complies with the required standard ESR-1413 SEE NOTES TO COMPLY WITH WATER RESISTIVE BARRIERS 17 ' - 6 " (N) 4X6 HDR (N) 4X6 HDR (N) 4X6 HDR (N) 4X6 HDR (N) 4X6 HDR (N) 4X6 HDR (N) 4X6 HDR (N) 4X6 HDR (N) 4X6 HDR (N) 4X6 HDR (N) 4X6 HDR (N) 4X6 HDR (N ) 4 X 6 HD R (N ) 4 X 6 HD R (N ) 4 X 6 HD R (N ) 2 X 1 0 C . J . @ 1 2 ' ' O . C . (N ) 2 X 6 R . R . @ 1 2 ' ' O . C . (N ) 2 X R . R . @ 1 6 ' ' O . C . (N ) 2 X R . R . @ 1 2 ' ' O . C . (N ) 2 X 6 R . R . @ 1 2 ' ' O . C . (N ) 2 X 6 R . R . @ 1 2 ' ' O . C . (N ) 2 X 6 R . R . @ 1 2 ' ' O . C . (N ) 2 X 1 0 C . J . @ 1 2 ' ' O . C . (N ) 2 X 1 0 C . J . @ 1 2 ' ' O . C . (N ) 4 X 6 HD R 2x8 RIDGE BOARD 2x8 RIDGE BOARD (N ) 4 X 6 HD R DATE: SCALE: Adan MoralesDRAFTER: PERMIT No SH E E T T I L E : DESIGN - PLANNING - PERMIT 7469 Foothill Blvd, Tujunga, CA 91042 Cel: (323) 516-5846 Email: info@arkitpp.com info@arkitpp.com Office Hours Monday - Friday: 8:00am to 6:00 pm THIS DESIGN AND DRAWINGS, ARE COPYRIGHT PROTECTED AND ARE THE EXCLUSIVE PROPERTY OF ARKIT PLANS & PERMIT, THEY SHALL BE NO USED, MODIFIED DUPLICATED IN WHOLE OR IN ANY MANNER, NOR ASSIGNED TO A THIRD PARTY WITHOUT THE WRITTEN AUTHORIZATION OF ARKIT PLANS & PERMIT. 1 REVISIONS SYMB DESCRIPTIONS DATE REVISION OWNER: Gustavo Valencia / Yannet Leal ADDRESS: 2223 S Rene Dr, Santa Ana, CA 92704 PROPOSED FOR: PROJECT MANAGEMENT:Rafael Estevez AS SHOWN N Approval stamp FEB 5 2026 NE W A D U 7 9 8 S Q . F T . AD.5 FO U N D A T I O N & F R A M I N G P L A N Note: Annular spaces around pipes, electrical cables, conduits or other openings in sole/bottom plates at exterior walls Shall be protected against the passage of rodents by closing such openings with cement mortar, concrete masonry or similar methods. SHEAR WALL 1/2" WOOD STRUCTURAL PANEL W/ 8D @ 6"/6"/12" O.C. 7/8" STUCCO O/ WOVEN WIRE OR EXPANDED METAL LATH W/ NO. 11 GA. NAILS 1-1/2"x7/16" HEADS W/ 1/4" FURRING APPLIES TO NAILING AT ALL STUDS TOP & BOTTOM PLATES & BLOCKING. WOOD SOLE PLATES AT ALL EXTERIOR WALLS ON MONOLITHIC SLABS, WOOD SOLE PLATES OF BRACED WALL PANELS AT BUILDING INTERIORS ON MONOLITHIC SLABS AND ALL WOOD SILL PLATES SHALL BE ANCHORED TO THE FOUNDATION WITH ANCHOR BOLTS SPACED A MAXIMUM OF 6 FEET (1829 MM)ON CENTER. BOLTS SHALL BE AT LEAST z INCH (12.7 MM) IN DIAMETER AND SHALL EXTEND A MINIMUM OF 7 INCHES (178 MM) INTO CONCRETE OR GROUTED CELLS OF CONCRETE MASONRY UNITS. A NUT AND WASHER SHALL BE TIGHTENED ON EACH ANCHOR BOLT. THERE SHALL BE A MINIMUM OF TWO BOLTS PER PLATE SECTION WITH ONE BOLT LOCATED NOT MORE THAN 12 INCHES (305 MM) OR LESS THAN SEVEN BOLT DIAMETERS FROM EACH END OF THE PLATE SECTION. INTERIOR BEARING WALL SOLE PLATES ON MONOLITHIC SLAB FOUNDATION THAT ARE NOT PART OF A BRACED WALL PANEL SHALL BE POSITIVELY ANCHORED WITH APPROVED FASTENERS. SILL PLATES AND SOLE PLATES SHALL BE PROTECTED AGAINST DECAY AND TERMITES WHERE REQUIRED BY SECTION R317 AND R318. COLD- FORMED STEEL FRAMING SYSTEMS SHALL BE FASTENED TO WOOD SILL PLATES OR ANCHORED DIRECTLY TO THE FOUNDATION AS REQUIRED IN SECTION R505.3.1 OR R603.3.1. 1 DETAIL 1/4" = 1'-0" FOUNDATION PLAN1 1/4" = 1'-0" FRAMING PLAN2 20 14 17 18 1) Depth of foundations below the natural grade shall not be less than 18 inches. 2) Continuous foundations shall be reinforced with at least four continuous #4 reinforcing bars, two #4 bars at the top and two #4 bars at the bottom. 3) Slab construction shall be minimum 4” thick, reinforced with #4 bars at 18” on center each way. 4) Doweling of the new foundations and slabs into the existing foundations and slabs shall be required. Dowels shall be a minimum of 6” into the existing concrete and shall extend a minimum of 24” into the new concrete. Dowels shall be minimum #3 bars at 18” on center or #4 bars at 24” on center. FOUNDATION NOTES: CERTIFICATE NO. 100081 SANTA ANA UNIFIED SCHOOL DISTRICT SCHOOL FACILITIES FEE CERTIFICATION OF COMPLIANCE AND RECEIPT FOR PAYMENT FOR Project Number:PRJ-1843672 Project Request ID:PA2BI5TOTC Request Contact:Isaac Miranda (CONTRACTOR) Job Location / Address: 2223 S Rene Dr, Santa Ana, CA 92704 Permit Issuing Office: City of Santa Ana This is to certify that all fees due to the Santa Ana Unified School District under Provision of Government Code Section 65995 as a prerequisite to the issuance of a Building Permit have been received, based on the above referenced information, this Certification is hereby Executed. PMT-622232 Address Development Type Construction Type Square Feet 2223 S Rene Dr, Santa Ana, CA 92704 Residential Accessory Dwelling Unit (ADU) 798 Permit Number 101126772 Plan Check Number 101126817 622232-Residential Accessory Dwelling Unit (ADU) fees as required in the amount of:$4,125.66 ($5.17 [Rate] x 798 [Square Footage]) Address Development Type Construction Type Square Feet 2223 S Rene Dr, Santa Ana, CA 92704 Residential Tear-Down / Rebuild 798 Permit Number 101124136 622232-Residential Tear-Down / Rebuild Credit given as required in the amount of:$-4,125.66 ($5.17 [Rate] x 798 [Square Footage]) Developer Fees Paid:$0.00 Jeremy Cogan School District Representative Date: 05/01/2026 CERTIFICATE NO. 100081 NOTICE OF 90-DAY PERIOD FOR PROTEST OF FEES Pursuant to Section 66020 of the California Government Code and other applicable law, you have a period of ninety (90) days from the date of payment of school fees, mitigation payments or other extractions to protest the validity thereof. This ninety (90) day period commences upon such payment of performance of any other requirement as provided in Section 66020. Any such protest must be in writing and received by the Santa Ana Unified School District within ninety (90) calendar days of the date of the School District Certification above.