GREASE INTERCEPTOR MEMORANDUM
To: Jin Sung - Applicant Date: 2/2/2026
Luis A. Dimas – Engineering Aide
From: PWA, Water Resources
Location: 305 W. 4TH ST. – OASIS CENTER INTERNATIONAL
The above referenced food service establishment (FSE) must comply with the Fats, Oils, and Grease
(FOG) Control Program Rules and Regulations as identified in Ordinance NS-2921 and as follows:
No improvements are required at this time. This FSE qualifies for at least one of the following
condition(s):
The proposed FSE’s FOG discharges are projected to be negligible and will not likely cause a significant
impact to the sewer system, or;
The proposed remodeling work does not increase the current amount of FOG generated, or;
The proposed remodeling work does not require: 1) under the slab plumbing in the kitchen area, 2) an
increase in the net public seating area, 3) an increase in the size of the kitchen area, or 4) any change in
the size or type of food preparation equipment, or
This is an existing FSE involving a change of ownership that will not result in an increase of FOG
discharged to the sewer system.
Special comments/conditions:
The developer/owner acknowledges that no tenant improvements that include change of plumbing in the
kitchen area, change of kitchen equipments, expansion of dining area, and or change in type of
operations or use, are being performed at this time. The developer/owner has been notified that any
improvements, that include that which is mentioned above, will result in the revocation of this waiver to
install a grease interceptor.
C/c: Water Resources Division
Planning & Building Agency
OC Health Care Agency
Public Works Agency (Development)
EEC Environmental
Applicant
CITY OF SANTA ANA
FOOD SERVICE ESTABLISHMENT
WASTEWATER DISCHARGE NOTICE
AND CONDITIONAL WAIVER
FSE ID: 97
FSE Owner: .tin sung
FSE Name: Oasis Center International
FSE Address: 305 w. 4th st.
FSE City, State, Zip: Santa Ana, CA, 92701
FSE Owner/Rep Email: sandro@madstudiola.com
A gravity grease interceptor is NOT required at this FSE:
Effective Date: 1/27/2026
CITY OF SANTA ANA
Planning and Building Agency
Approved
FOR PERMIT ISSUANCE
Master ID:
Date:
FSE Owner/Rep Phone: (442) 288-8720
Effective August 1, 2017, the City of Santa Ana adopted Ordinance Number NS 2921 amending Chapter 39
of the Santa Ana Municipal Code adding fats, oils and grease (FOG) control regulations applicable to Food
Service Establishments (FSEs). The ordinance requires all new and remodeled FSEs to install and maintain
grease interceptors. FSEs without grease interceptors and that meet certain criteria are hereby issued a
conditional waiver under the terms of this Notice and Conditional Waiver.
FSEs will be routinely inspected to evaluate the effectiveness of their grease control measures. Existing FSEs
that discharge FOG and are out of compliance with the Ordinance provisions will be required to install grease
interceptors. All FSEs must implement Kitchen Best Management Practices (BMPs) to remove FOG from the
waste stream entering the sewer system.
Program Rules and Regulations
The City has established Rules and Regulations for the FOG Program. Refer to the City website at
https://www.santa-ana.org/documents/fog-program-rules-and-regulations/ or contact the FOG Control
Program Manager at (714) 647-3320 for copies of the Rules and Regulations. Also refer to these sources for
the Fats, Oils, and Grease Control Regulations (Section 39-56 of the City's Municipal Code) and for copies
of forms and educational material.
Conditional Waiver
A Conditional Waiver to the requirement to install a grease interceptor is hereby granted. This waiver may be
revoked at any time upon a determination of one or more of the following:
1. Quantity of FOG discharge as measured or as indicated by the size of the FSE based on seating
capacity, number of meals served, menu, water usage, amount of on -site consumption of prepared
food and other conditions have changed since the granting of said waiver such that the FSE is
contributing to FOG discharges.
2. Any tenant or facility modification, addition or alteration of cooking or food preparation equipment
3. Identification of the FSE as a significant contributor of FOG into the Sewer System, which is based on
inspection or sampling of the FOG discharged from the FSE's sewer lateral to the Sewer System.
4. Adequacy of implementation and compliance with Kitchen Best Management Practices (BMPs).
5. Change in sewer size, grade, and condition based on visual information.
6. Failure to comply with any of the specific requirements set forth below in this Conditional Waiver.
7. Any other condition deemed reasonably related to the generation of FOG discharges by the FOG
Control Program Manager.
Page 1 of 2
CITY OF SANTA ANA
Planning and Building Agency
Current FSE Equipment
Approved
FOR PERMIT ISSUANCE
FSE acknowledges that below is the existing cooking equipment of the facility and that no ct
anges will or.rur.
Master ID:
Equipment
#
Equipment
#
Equipment
#
Equi
r®er*:
4
Automatic
Dishwasher
1
Grill
0
Rethermalizer
0
3 Compartment
Sink
Broiler
0
Hood
0
Rotisserie
0
Tilt Skillet
0
Char Broiler
0
Kettle
0
Skillet
0
Wok
0
Deep Fryer
0
Oven
0
Smoker
0
Stove
0
Griddle
0
Pressure Cooker
0
Steamer
0
Notice and Conditional Waiver Amendment Notice
The Developer/Owner acknowledges that no tenant improvements that include change of kitchen equipment,
expansion of dining area, and or change in type of operations or use, are being performed at this time. The
developer/owner has been notified that any improvements, that include what is mentioned above, will result in
the revocation of this waiver to install a grease interceptor. The City may amend this Notice and/or Conditional
Waiver at any time. Compliance with the requirements contained in this Notice and Conditional Waiver does
not relieve the FSE of its obligation to comply with the Fats, Oils, and Grease Control Regulations, any
applicable pretreatment regulations, standards or requirements under local, State, and Federal laws, including
any such regulations, standards, requirements or laws that may become effective during the term of this
Conditional Waiver. Non-compliance with any term or condition of this Notice and Conditional Waiver
constitutes a violation of the Fats, Oils and Grease Control Regulation and may result in revocation of the
Conditional Waiver.
Print Name (FSE Owner/Representative) I Sign Name (FSE Owner/Representative) I Date
BY signing, FSE owner agrees to all terms and conditions of this Notice and Conditional Waiver.
ma o Fernandez
Acti g Deputy Public Works Director
Water Resources Manager
Page 2 of 2
CITY OF SANTA ANA
FOOD SERVICE ESTABLISHMENT
WASTEWATER DISCHARGE NOTICE
AND CONDITIONAL WAIVER
FSE ID: 97
FSE Owner: .tin sung
FSE Name: Oasis Center International
FSE Address: 305 w. 4th st.
FSE City, State, Zip: Santa Ana, CA, 92701
FSE Owner/Rep Email: sandro@madstudiola.com
A gravity grease interceptor is NOT required at this FSE:
Effective Date: 1/27/2026
CITY OF SANTA ANA
Planning and Building Agency
Approved
FOR PERMIT ISSUANCE
Master ID:
Date:
FSE Owner/Rep Phone: (442) 288-8720
Effective August 1, 2017, the City of Santa Ana adopted Ordinance Number NS 2921 amending Chapter 39
of the Santa Ana Municipal Code adding fats, oils and grease (FOG) control regulations applicable to Food
Service Establishments (FSEs). The ordinance requires all new and remodeled FSEs to install and maintain
grease interceptors. FSEs without grease interceptors and that meet certain criteria are hereby issued a
conditional waiver under the terms of this Notice and Conditional Waiver.
FSEs will be routinely inspected to evaluate the effectiveness of their grease control measures. Existing FSEs
that discharge FOG and are out of compliance with the Ordinance provisions will be required to install grease
interceptors. All FSEs must implement Kitchen Best Management Practices (BMPs) to remove FOG from the
waste stream entering the sewer system.
Program Rules and Regulations
The City has established Rules and Regulations for the FOG Program. Refer to the City website at
https://www.santa-ana.org/documents/fog-program-rules-and-regulations/ or contact the FOG Control
Program Manager at (714) 647-3320 for copies of the Rules and Regulations. Also refer to these sources for
the Fats, Oils, and Grease Control Regulations (Section 39-56 of the City's Municipal Code) and for copies
of forms and educational material.
Conditional Waiver
A Conditional Waiver to the requirement to install a grease interceptor is hereby granted. This waiver may be
revoked at any time upon a determination of one or more of the following:
1. Quantity of FOG discharge as measured or as indicated by the size of the FSE based on seating
capacity, number of meals served, menu, water usage, amount of on -site consumption of prepared
food and other conditions have changed since the granting of said waiver such that the FSE is
contributing to FOG discharges.
2. Any tenant or facility modification, addition or alteration of cooking or food preparation equipment
3. Identification of the FSE as a significant contributor of FOG into the Sewer System, which is based on
inspection or sampling of the FOG discharged from the FSE's sewer lateral to the Sewer System.
4. Adequacy of implementation and compliance with Kitchen Best Management Practices (BMPs).
5. Change in sewer size, grade, and condition based on visual information.
6. Failure to comply with any of the specific requirements set forth below in this Conditional Waiver.
7. Any other condition deemed reasonably related to the generation of FOG discharges by the FOG
Control Program Manager.
Page 1 of 2
Sandro Polo 01/29/2026
305 W 4TH STREET, SANTA ANA, CA, 92701
SYMBOLS
BUILDING DEPARTMENT NOTES
FIRE DEPARTMENT NOTES
PROJECT DIRECTORY SHEET INDEXABBREVIATIONS
VICINITY MAP
BUILDING SUMMARY/SCOPE OF WORK
ARCHITECTURAL DRAWINGSEXISTING BUILDING INFORMATION
CONSTRUCTION TYPE:
NUMBER OF FLOORS:
SPRINKLERED:
OCCUPANCY TYPE:
PARCEL:
LEGAL DESCRIPTION:
ROOM DESIGNATION
ELEVATION NUMBER
V-B
EXISTING 3 (AND BASEMENT LEVEL)
YES (EXISTING) - ALL MODIFICATION SHALL BE REVIEWED AND APPROVED BY OCFA
PRIOR TO FINAL OF THE BUILDING PERMIT.
EXISTING 'B'
398-255-20
SEC 12 T5R10 LOT2 25 X 100 FT
CAfe oasis
1
ROOM NAME
No.
MECHANICAL DRAWINGS
ELECTRICAL DRAWINGS
PLUMBING DRAWINGS
id1.0 DEMOLITION PLAN AND CEILING DEMO PLAN
id2.0 PARTITION PLAN AND REFLECTED CEILING PLAN
id2.1 POWER & SIGNAL PLAN AND FURNITURE PLAN (FOR REFERENCE ONLY)
id2.2 WALL FINISH PLAN AND FLOOR FINISH PLAN
id3.0 DOOR AND HARDWARE SCHEDULE
id4.0 INTERIOR ELEVATIONS
id4.1 INTERIOR ELEVATIONS
id5.0 PARTITION CONSTRUCTION DETAILS
id5.2 CEILING CONSTRUCTION DETAILS
id6.0 MILLWORK DETAILS
M1.0 MECHANICAL DEMOLITION AND REMOVAL PLAN
M2.0 MECHANICAL DETAILS SHEET
E0.1 ELECTRICAL LEAD SHEET
E0.3 ELECTRICAL TITLE 24
P0.1 PLUMBING LEAD SHEET
P2.0 PLUMBING REMODEL PLANS
ADJUSTABLE
ACOUSTICAL
ACOUSTICAL
ABOVE FINISH FLOOR
ARCHITECTURAL
BUILDING
BOTTOM
ANODIZED
APPROXIMATE
CONTRACTOR
COLUMN
CONCRETE
CONNECTION
CONTINUOUS
CENTERLINE
DRINKING FOUNTAIN
DIAMETER
DIAMETER
EXISTING
DIMENSION
DRAWING
CORRIDOR
CERAMIC TILE
FINISH FACE
EXPOSED
FLOOR DRAIN
GALVANIZED
FIRE EXTINGUISHER
ALUMINUM
F.F.
GAUGEGA.
GALV.
FT.FOOT
FIN.
FLR.
FINISH
FLOOR
DOORDR.
EQUALEQ.
EXP.
F.D.
F.E.C.
(E)
DWG.
D.F.
Ø
DIA.
DIM.
CORR.
C.T.
DET.DETAIL
BOARDBD.
CONC.
CONN.
CONT.
CONTR.
COL.
CLO.
CLR.
CLOSET
CLEAR
C
CLG.CEILING
BLDG.
BLK.
BOT.
BLOCK
A.F.F.
ANOD.
@
APPROX.
ARCH.
AT
ACOUS.
ALUM.
A.C.T.
ADJ.
SOLID CORE
VINYL COMPOSITIONV.C.T.
WALL COVERINGW.C.
WD.WOOD
W/
W/O WITHOUT
WITH
SCHEDULED
STANDARD
SPECIFICATIONS
STAINLESS STEEL
STRUCTURAL
SUSPENDED
TELEPHONE
TEMPERED GLASS
UNLESS OTHERWISE
STORAGESTOR.
TEMP.GL.
THK.
TYP.
U.O.N.
TYPICAL
THICK
SUSP.
STRUCT.
TELE.
SPECS.
STD.
STL.
S.S.
STEEL
S.C.
SCHED.
SECT.
SIM.
SECTION
SIMILAR
MISC.
NOT IN CONTRACT
NOT TO SCALE
ON CENTER
OPPOSITE HAND
OWNER PROVIDE &
RM.
REQ'D.REQUIRED
ROOM
O.P.I.
OPNG.
OPP.
OPENING
O.C.
O.P.C.I.
O/OVER
MTD.
N.I.C.
N.T.S.
MOUNTED
HARDWOOD
GYPSUM BOARD
LAVATORY
MECHANICAL
MANUFACTURER
MISCELLANEOUS
HDWD.
MECH.
MFR.
MIN.
MET./MTL.
MINIMUM
METAL
HT.
LAV.
HEIGHT
GL.
GYP. BD.
GLASS
L
CABINETCAB.
ABANDON(A)
(D)DEMOLISH
CONTRACTOR INSTALL
OWNER PROVIDE &
CABINET
INSTALL
NOTED
TILE
CEILING TILE
F.O.S.FACE OF STUD
MAXIMUMMAX.
MUL.MULLION
R.O.ROUGH OPENING
V.I.F.VERIFY IN FIELD
SPACESP.
(R)RELOCATED
CEILING HEIGHT REFERENCE
KEY NOTE
ELEVATION REFERENCE
SHEET NUMBER
DETAIL NUMBER
DETAIL REFERENCE
SHEET NUMBER
SECTION NUMBER
SECTION REFERENCE
SHEET NUMBER
DETAIL NUMBER
PLAN DETAIL REFERENCE
SHEET NUMBER
A
ALIGNMENT OF NEW AND EXISTING ELEMENTS
MAT.SURFACE MATERIAL REFERENCE
1 FIXTURE REFERENCE
1 EQUIPMENT REFERENCE
WALL FINISH SPECIFICATION
BASE MATERIAL SPECIFICTION
WALL/BASE FINISH REFERENCE
FLOOR FINISH REFERENCEC
1
FLOOR FINISH DIRECTION
FLOOR FINISH TRANSITIONFINFIN
NORTH
APPLICABLE CODES:
STATE BUILDING STANDARDS (CCR, TITLE 24, 2025 EDITION)
MECHANICAL ELECTRICAL PLUMBING WORK SHALL BE ON SEPERATE BUILDING PERMITS.
FIRE LIFE SAFETY/FIRE PROTECTION WORK SHALL BE ON SEPARATE PERMITS.
PART 2.CALIFORNIA BUILDING CODE W/ CITY AMMENDMENTS
PART 3.CALIFORNIA ELECTRICAL CODE W/ CITY AMMENDMENTS
PART 4.CALIFORNIA MECHANICAL CODE W/ CITY AMMENDMENTS
PART 5.CALIFORNIA PLUMBING CODE W/ CITY AMMENDMENTS
PART 6.CALIFORNIA ENERGY EFFICIENCY STANDARDS W/ CITY AMMENDMENTS
PART 7.CALIFORNIA ELEVATOR SAFETY CONSTRUCTION CODE W/ CITY AMMENDMENTS
PART 8.CALIFORNIA HISTORICAL BUILDING CODE W/ CITY AMMENDMENTS
PART 9.CALIFORNIA FIRE CODE W/ CITY AMMENDMENTS
PART 10 CALIFORNIA CODE FOR BUILDING CONSERVATION W/ CITY AMMENDMENTS
PART 12 CALIFORNIA REFERENCE STANDARDS CODE W/ CITY AMMENDMENTS
id5.1 CONSTRUCTION DETAILS
id0.0 COVER SHEET
id0.1 GENERAL NOTES
id0.2 GENERAL NOTES
id0.4 NOT USED
id0.3 GENERAL ACCESSIBILITY NOTES
DEFERRED SUBMITTALS:
FIRE PROTECTION WORK - BACK-FLOW ASSEMBLY UPGRADES UNDER SEPARATE PERMIT.
1.FIRE PROTECTION WORK SHALL BE PERFORMED ON A DESIGN/BUILD BASIS UNDER SEPARATE PERMITS.
2.RESPECTIVE CONTRACTORS SHALL BE RESPONSIBLE FOR PLAN CHECK REVIEWS/APPROVALS AND
SECURING APPROPRIATE BUILDING PERMITS.
DESIGN BUILD WORK
1.ALL WORK SHALL CONFORM TO THE 2025 CALIFORNIA BUILDING CODE.
2.THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY
WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL-BOXES, TRANSFORMERS, VAULTS, PUMPS,
VALVES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION
SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES-WHETHER OR NOT THE LINES ARE LOCATED ON THE
PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES.
3.THE FACILITIES INCLUDING, BUT NOT LIMITED TO, SANITARY FACILITIES, DRINKING FOUNTAINS, AND
ELEVATORS ON ALL FLOORS, MUST COMPLY WITH ACCESSIBILITY REQUIREMENTS.
4.TOILET FACILITIES SHALL BE IDENTIFIED BY SIGNAGE IN COMPLIANCE WITH THE INTERNATIONAL SYMBOL OF
ACCESSIBILITY (CBC CHAPTER 11).
5.THE PATH OF TRAVEL FROM THE DESIGNATED HANDICAP PARKING SPACES AND THE PUBLIC SIDEWALK
PROVIDES A FREE AND UNOBSTRUCTED PASSAGE FOR ACCESS TO AND EGRESS FROM THE AREA OF WORK.
6.DOORS SHALL BE NOT LESS THAN 3'-0" IN WIDTH AND NOT LESS THAN 6'-8" IN HEIGHT.
7.FLOORS OR LANDINGS LOCATED AT A DOORWAY SHALL BE NOT MORE THAN 1/2" LOWER THAN THE TOP OF
THE THRESHOLD, WHICH SHALL HAVE A 1/4" MAXIMUM VERTICAL EDGE AND A CHANGE IN LEVEL NOT
GREATER THAN 1:2.
8.A CLEAR AND LEVEL AREA SHALL BE PROVIDED ON EACH SIDE OF EXIT DOORS WITH A LENGTH OF AT LEAST
60" IN THE DIRECTION OF THE DOOR SWING AND AT LEAST 48" IN THE OPPOSITE DIRECTION, MEASURED AT
RIGHT ANGLES THE DOOR IN ITS CLOSED POSITION.
HEIGHT
MATERIAL
SCOPE OF WORK:
TENANT IMPROVEMENT TO EXISTING OFFICE SPACE. EXISTING 'B'
OCCUPANCY TO REMAIN, NO CHANGE IN USE.
1ST FLOOR USABLE AREA:±2,133 SQ.FT.
SCOPE OF WORK:±800 SQ.FT.
1.THE CONTRACTOR SHALL SUPPLY AND INSTALL A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS
THAN 2-A OR 2-A10BC WITHIN 75'-0" TRAVEL DISTANCE TO ALL PORTIONS OF THE FLOOR, AND ANY
ADDITIONAL FIRE EXTINGUISHERS AS REQUIRED BY FIRE DEPARTMENT FIELD INSPECTOR. FIRE EXTINGUISHERS
SHALL ALSO BE PROVIDED DURING CONSTRUCTION.
2.DRAPES AND OTHER DECORATIVE MATERIALS SHALL BE FLAME RETARDANT. CERTIFICATION THEREOF SHALL BE
PROVIDED. EXITS, EXIT LIGHTS, FIRE ALARM STATIONS, HOSE CABINETS AND EXTINGUISHER LOCATIONS
SHALL NOT BE CONCEALED BY DECORATIVE MATERIAL (CBC CHAPTER 8).
3.INTERIOR WALL AND CEILING FINISHES FOR OFFICES SHALL BE OF CLASS C PER TABLE 803.11AND NOT
EXCEED A FLAME SPREAD INDEX OF 76-200 PER SECTION 803.1.1 OF CBC 2022.
4.INTERIOR WALL AND CEILING FINISHES FOR EXIT CORRIDORS AND STAIRWELLS SHALL BE OF CLASS B PER
TABLE 803.11 AND NOT EXCEED THE FLAME SPREAD INDEX OF 26-75 PER SECTION 803.1.1 OF CBC 2022.
5.ANY DECORATIONS USED SHALL BE NON-COMBUSTIBLE OR FLAME-RETARDANT TREATED IN AN APPROVED
MANNER (CURTAINS, DRAPES, SHADES, ETC.).
6.EXIT SIGNS SHALL BE ELECTRICALLY ILLUMINATED AND THE TWO LAMPS SHALL BE ENERGIZED FROM SEPARATE
CIRCUITS. ILLUMINATION SHALL NORMALLY BE PROVIDED BY THE PREMISES WIRING SYSTEMS. IN THE EVENT
OF THIS SYSTEM'S FAILURE, ILLUMINATION SHALL BE AUTOMATICALLY PROVIDED FROM AN EMERGENCY
SYSTEM. EMERGENCY LIGHTING SHALL GIVE A VALUE OF ONE FOOT-CANDLE AT FLOOR LEVEL (CBC
CHAPTER 10).
7.WHENEVER THE BUILDING IS OCCUPIED, EXIT SIGNS SHALL BE LIT SO THAT THEY ARE CLEARLY VISIBLE.
8.PROVIDE EXIT SIGNS WITH MINIMUM 6" HIGH BLOCK LETTERS WITH 3/4" STROKE ON A CONTRASTING
BACKGROUND. INDICATE THE LOCATION OF EXIT SIGNS ON PLANS (CBC CHAPTER 10).
9.EXIT PATH LIGHTING SHALL BE PROVIDED AT STAIRWAY, HALLWAY, EXIT PASSAGEWAY, AND EGRESS TO A
PUBLIC WAY WHENEVER THE BUILDING IS OCCUPIED, PER CBC CHAPTER 10.
10.EMERGENCY LIGHTING SYSTEM IS REQUIRED AND MUST COMPLY WITH CBC CHAPTER 10.
11.ALL FIRE ALARM DEVICES SHALL BE LOCATED AS NOTED BELOW.
12.ALTERATIONS TO THE FIRE AND LIFE SAFETY SYSTEM SHALL BE UNDER SEPARATE PERMIT FROM THE FIRE
PREVENTION SECTION PLANS. PERMIT APPLICATIONS AND FEES SHALL BE SUBMITTED AND PERMIT APPROVAL
SHALL BE OBTAINED PRIOR TO COMMENCEMENT OF ANY WORK ON THE FIRE AND LIFE SAFETY SYSTEM.
13.PROVIDE AN APPROVED FIRE ALARM SYSTEM WITH A DESCRIPTION OF SEQUENCE OF OPERATION AND LISTED
STATE FIRE MARSHALL APPROVED EQUIPMENT.
14.SUBMIT THREE COMPLETE SETS OF PLANS TO ELECTRICAL DIVISION, DEPARTMENT OF BUILDING AND SAFETY
FOR THE ABOVE REQUIREMENTS, ONE SET DESIGNATED AS THE FIRE DEPARTMENT COPY.
15.PROVIDE AUTOMATIC FIRE EXTINGUISHING SYSTEM THROUGHOUT THE FLOOR. ALTERATIONS TO THE
AUTOMATIC FIRE SPRINKLER SYSTEM SHALL BE UNDER SEPARATE PERMIT FROM THE FIRE PREVENTION
SECTION PLANS. PERMIT APPLICATIONS AND FEES SHALL BE SUBMITTED AND PERMIT APPROVAL SHALL BE
OBTAINED PRIOR TO COMMENCEMENT OF ANY WORK ON THE FIRE PROTECTION SYSTEM.
16.SPRINKLER SYSTEM SHALL BE APPROVED BY PLUMBING DIVISION OF LOCAL BUILDING DEPARTMENT PRIOR TO
INSTALLATION (CBC CHAPTER 9).
17.ELEVATOR DOORS SHALL NOT OPEN DIRECTLY INTO ONE-HOUR CORRIDORS (CBC CHAPTER 30).
18.KEY-LOCKING HARDWARE MAY BE USED ON THE MAIN EXIT WHEN THE MAIN EXIT CONSISTS OF A SINGLE
DOOR OR PAIR OF DOORS IF THERE IS A READILY VISIBLE, DURABLE SIGN ON OR ADJACENT TO THE DOOR
STATING "THIS DOOR MUST REMAIN UNLOCKED DURING BUSINESS HOURS".
19.EXIT CORRIDORS, EXTERIOR EXIT BALCONIES, AND AISLES LEADING TO REQUIRED EXITS SHALL HAVE A
MINIMUM WIDTH OF 44" (CBC CHAPTER 10).
20.AN EXIT WALKWAY WITH A MINIMUM WIDTH OF 44" SHALL BE MAINTAINED CONTINUOUSLY TO A PUBLIC
WAY (CBC CHAPTER 10). EXIT PATHS OR WALKWAYS TO PUBLIC WAY SHALL BE CLEARLY DELINEATED BY
PAINTED LINES, RAILINGS, BARRIER POSTS, WALKS, OR OTHER APPROVED MEANS.
21.GLAZING INSTALLED IN ONE-HOUR CORRIDOR MUST BE 1/2" WIRED GLASS IN STEEL FRAMES AND SHALL
NOT EXCEED 25% OF CORRIDOR/ROOM COMMON WALL.
22.FIRE DAMPERS OR DOORS SHALL BE PROVIDED WHERE HVAC DUCTS PENETRATE FIRE-RATED WALLS OR
CEILINGS.
id0.5 EXISTING SITEPLAN/ P.O.T. (FOR INFORMATION ONLY)
id0.7 OCCUPANCY/EGRESS PLAN
id0.6 EXISTING RESTROOMS (FOR INFORMATION ONLY)
MAD STUDIOMAD
OWNER/LANDLORD:S&A MANAGEMENT
RYAN CHASE
129 W. WILSON ST., STE 100
COSTA MESA, CA 92627
EMAIL:
DESIGN FIRM:MAD STUDIO
ED MELGAR
670 GLENMORE BLVD.
GLENDALE, CALIFORNIA 91206
EMAIL: ed@madstudiola.com
PHONE: 818.795.3900
GENERAL CONTRACTOR:CLUNE CONSTRUCTION
JASON RIVERA
725 S. FIGUEROA ST., STE 300
LOS ANGELES, CA 90017
PHONE: 213.437.6260
EMAIL: jrivera@clunegc.com
MEP ENGINEERS:LAM AND KAAINONI ENGINEERING
MATT KAAINONI
617 W. 7TH STREET, STE 301
LOS ANGELES, CA 90017
EMAIL: matt.kaainoni@lamkaainoni.com
TENANT OASIS CENTER INTERNATIONAL
JIN SUNG
305 W. 4TH STREET
SANTA ANA, CA 92701
EMAIL: jsung@oasiscenterintl.org
PROJECT SITE
M0.1 MECHANICAL LEAD SHEET
M0.2 MECHANICAL SCHEDULE SHEET
E0.2 ELECTRICAL SINGLE LINE AND DETAILS
E1.0 ELECTRICAL DEMOLITION AND POWER PLANS
E2.0 ELECTRICAL LIGHTING AND PHOTOMETRIC PLANS
P1.0 PLUMBING DEMOLITION PLAN
P3.0 PLUMBING DIAGRAMS
P4.0 PLUMBING DETAILS
Sheet Title:
ISSUE DATE
ISSUE FOR PLANCHECK 12.22.2025
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ENGINEER/CONSULTANT
ARCHITECT/ENGINEER STAMP
30
5
W
4
T
H
S
T
R
E
E
T
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
1
CA
F
E
OA
S
I
S
CLIENT
www.madstudiola.com
CITY STAMP
Project Director:
Project Designer:
Project Tech:
Project No:25030.300E.M.
E.M.
S.P.
ISSUED FOR MEP 01.13.2026
ISSUED FOR PLAN CHECK COMMENTS- PLANNING DEPT.01.22.2026
ISSUED FOR PRICING 02.17.2026
ISSUED FOR PLAN CHECK COMMENTS - PLANNING DEPT.02.20.2026
ISSUED FOR COUNTY REVIEW 03.24.2026
ISSUED FOR ADDENDUM A 03.27.2026
ISSUED FOR BUILDING DEPT REVIEW 04.08.2026
ISSUED FOR BUILDING DEPT REVIEW - RESUBMITTAL 05.05.2026
ISSUED FOR BUILDING DEPT CORRECTIONS 05.20.2026
ID0.0
COVER SHEET
GENERAL CONDITION NOTES
1.THESE DRAWINGS, NOTES, AND SCHEDULES CONVEY THE DESIGN INTENT. THE HIGHEST POSSIBLE QUALITY
OF WORKMANSHIP, MATERIAL, AND EQUIPMENT SHALL BE USED.
2.THESE DOCUMENTS INCORPORATE THE AIA GENERAL CONDITIONS OF THE CONTRACT FOR
CONSTRUCTION (AIA DOCUMENT A201 2017) AND SUPPLEMENTAL CONDITIONS PREPARED BY MAD, IF ANY,
BY REFERENCE. BIDDERS ARE REQUIRED TO BECOME FAMILIAR WITH THESE DOCUMENTS, WHICH CAN BE
OBTAINED FROM MAD.
3.THE BUILDING SHALL COMPLY WITH CBC CHAPTER 11B ACCESSIBILITY REQUIREMENTS AT ENTRANCE, PATH
OF TRAVEL TO AREA OF WORK, AND ANY REVISIONS OR ADDITIONAL WORK REQUIRED BY THE TENANT, FIELD
CONDITIONS, OR LOCAL GOVERNING AUTHORITIES SHALL BE BROUGHT TO THE ATTENTION OF THE
OWNER AND MAD BEFORE PROCEEDING, REGARDLESS OF COST, TIME, OR MATERIAL INCREASE.
4.ALL WORK PERFORMED BY THE CONTRACTOR SHALL CONFORM TO THE REQUIREMENTS OF MUNICIPAL,
LOCAL OR FEDERAL AND STATE LAWS AS WELL AS ANY OTHER GOVERNING REQUIREMENTS, WHETHER OR
NOT SPECIFIED ON THE DRAWINGS.
5.CONTRACTOR SHALL ENSURE THAT INSTALLATION METHODS CONFORM TO ALL BUILDING CODE
REQUIREMENTS. THE MATERIALS SPECIFIED ARE INTENDED TO MEET CODE REQUIREMENTS. ANY
DISCREPANCY BETWEEN THE CONSTRUCTION DOCUMENTS AND CODE REQUIREMENTS SHALL BE BROUGHT
TO THE ATTENTION OF MAD IMMEDIATELY BY THE CONTRACTOR, AND PRIOR TO PERFORMANCE OF
SPECIFIED WORK.
6.WHERE THE CONTRACT DOCUMENTS CALL FOR ANY WORK OF A MORE STRINGENT NATURE THAN THAT
REQUIRED BY THE BUILDING CODE OR ANY OTHER DEPARTMENT HAVING JURISDICTION OVER THE WORK,
THE WORK OF THE MOST STRINGENT NATURE CALLED FOR BY THE CONTRACT, CONSTRUCTION NOTES, OR
DRAWINGS SHALL BE FURNISHED IN ALL CASES.
7.ALL WORK LISTED, SHOWN, OR IMPLIED ON ANY CONSTRUCTION DOCUMENT SHALL BE SUPPLIED AND
INSTALLED BY THE CONTRACTOR, UNLESS SPECIFICALLY NOTED "NOT IN CONTRACT".
8.THE CONTRACTOR SHALL SUBMIT A DETAILED CONSTRUCTION SCHEDULE TO THE OWNER INDICATING
PHASING OF WORK FROM START TO FINISH OF THE PROJECT.
9.INSURANCE AND BONDING FOR THE PROJECT SHALL BE AS DIRECTED BY AND TO THE SATISFACTION OF THE
OWNER.
10.THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LEGALLY REQUIRED APPROVALS AND PERMITS NECESSARY
FOR THE EXECUTION AND COMPLETION OF HIS WORK AND SHALL FORWARD COPIES OF EXECUTED PERMITS
TO MAD AND TO LANDLORD.
11.ALL MAD DRAWINGS AND ALL CONSTRUCTION NOTES ARE COMPLEMENTARY, AND WHAT IS CALLED FOR BY
EITHER WILL BE BINDING AS IF CALLED FOR BY ALL. ANY WORK SHOWN OR REFERRED TO ON ANY ONE SET
OF DRAWINGS SHALL BE PROVIDED AS THOUGH SHOWN ON ALL RELATED DRAWINGS.
12.THE CONTRACTOR IS WHOLLY RESPONSIBLE FOR THE COORDINATION AND SCHEDULING OF THE WORK
FOR ALL SUBCONTRACTORS, CRAFTSMEN, AND TRADESMEN REQUIRED TO COMPLETE THE JOB.
13.THE CONTRACTOR SHALL NOTIFY MAD IMMEDIATELY IF HE CANNOT COMPLY WITH ALL REQUIREMENTS
CALLED FOR ON THESE DRAWINGS.
14.THE CONTRACTOR SHALL NOTIFY MAD IMMEDIATELY OF ANY DISCREPANCIES OR OMISSIONS BETWEEN THE
DRAWINGS, THESE NOTES, AND FIELD CONDITIONS, AND REQUEST CLARIFICATION BEFORE COMMENCING
ANY WORK.
15.BY ENTERING INTO AN AGREEMENT WITH THE OWNER, THE CONTRACTOR REPRESENTS THAT HE HAS VISITED
THE JOB SITE, FAMILIARIZED THEMSELVES WITH EXISTING CONDITIONS, AND NOTED ANY DISCREPANCIES
WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS.
16.DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. LARGE SCALE DETAILS GOVERN OVER SMALLER SCALE
DETAILS.
17.ALL SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS ARE CONSIDERED CONSTRUCTION
STANDARDS. IF THE CONTRACTOR HAS QUESTIONS REGARDING THEIR DEFINITION, MAD SHALL BE NOTIFIED
FOR CLARIFICATION.
18.CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE RELATING TO THE
WORK OF EACH TRADE. NO ALLOWANCE SHALL BE MADE FOR ANY EXTRA EXPENSE OR EXTENSION OF TIME
DUE TO CONTRACTOR'S FAILURE OR NEGLIGENCE IN COMPLETELY EXAMINING THE JOB SITE.
19.CONTRACTOR SHALL CONTACT BUILDING MANAGEMENT TO DETERMINE THE BUILDING OWNER'S RULES
FOR CONSTRUCTION, DELIVERIES, CONSTRUCTION TASKS TO BE PERFORMED OUTSIDE REGULAR BUSINESS
HOURS ONLY, AND ANY OTHER SPECIAL BUILDING REQUIREMENTS WHICH WILL AFFECT THE WORK. IF
OVERTIME WORK IS REQUIRED BY ANY TRADE, APPROVAL (INCLUDING COST APPROVAL) MUST BE OBTAINED
PRIOR TO THE EXECUTION OF ANY WORK. THE GENERAL INTENT IS THAT ALL WORK EXCEPT FOR
NOISE-GENERATING CONSTRUCTION SHALL BE PERFORMED ON REGULAR TIME.
20.THE GENERAL CONTRACTOR, SUBCONTRACTORS, AND ANY OTHER CONTRACTOR INVOLVED IN THIS
PROJECT SHALL TAKE NOTE THAT ANY COSTS DUE TO DEFECTIVE AND/OR ILL-TIMED WORK AS A RESULT OF,
BUT NOT LIMITED TO, INFERIOR WORKMANSHIP OR MATERIALS AND/OR IMPROPER SCHEDULING OR
DELINQUENT ORDERING, SHALL BE BORNE BY THE PARTY RESPONSIBLE.
21.THE GENERAL CONTRACTOR SHALL REMOVE ALL RUBBISH AND WASTE MATERIALS FROM HIS OWN AND HIS
SUBCONTRACTORS' WORK, CARPET AND TELECOMS INSTALLATION, ETC., AND PROVIDE FOR ITS REMOVAL
FROM THE JOB SITE.
22.THE CONTRACTOR SHALL EXERCISE STRICT DUST CONTAINMENT CONTROL TO PREVENT DIRT OR DUST FROM
LEAVING THE JOB SITE.
23.THE CONTRACTOR SHALL PROVIDE PROTECTION DURING SITE WORK, DEMOLITION, AND CONSTRUCTION.
THE CONTRACTOR SHALL PROTECT ALL AREAS FROM DAMAGE WHICH MAY OCCUR DURING
CONSTRUCTION. ANY DAMAGE TO NEW AND EXISTING CONSTRUCTION, STRUCTURE, OR EQUIPMENT
SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE OWNER, AT THE EXPENSE OF THE
CONTRACTOR.
24.THE CONTRACTOR SHALL MAINTAIN A CURRENT AND COMPLETE SET OF CONSTRUCTION DRAWINGS ON
SITE DURING ALL CONSTRUCTION PHASES FOR THE USE OF ALL TRADES. THE CONTRACTOR SHALL SEE THAT
ALL SUBCONTRACTORS RECEIVE COMPLETE SETS OF CONSTRUCTION DRAWINGS, OR ASSUME FULL
RESPONSIBILITY FOR COORDINATION OF WORK WHEN COMPLETE SETS ARE NOT AVAILABLE TO
SUBCONTRACTORS.
25.ALL EXISTING MANUFACTURED ITEMS NOT BEING REMOVED SHALL BE REFURBISHED AS REQUIRED, ANY
LOOSE ITEMS TIGHTENED (INCLUDING, BUT NOT LIMITED TO, EXIT SIGNS, DOWNLIGHTS, SPEAKERS,
MOLDINGS, ETC.), AND ANY MISSING PARTS REPLACED BY THE CONTRACTOR TO ACHIEVE A COMPLETE
INSTALLATION WITH A NEW APPEARANCE.
26.ALL REQUIRED EXITS, WAYS OF APPROACH THERETO, AND WAYS OF TRAVEL FROM THE EXIT INTO THE STREET
SHALL CONTINUOUSLY BE MAINTAINED FREE FROM ALL OBSTRUCTIONS AND IMPEDIMENTS FOR EGRESS IN
CASE OF FIRE OR OTHER EMERGENCY.
27.DURING THE ENTIRE PERIOD OF DEMOLITION AND CONSTRUCTION, ALL EXISTING EXIT SIGNS, EXIT
LIGHTING, FIRE PROTECTION DEVICES AND ALARMS SHALL BE CONTINUOUSLY MAINTAINED.
28.THE CONTRACTOR SHALL VERIFY SIZE, LOCATION, ELECTRICAL REQUIREMENTS, AND CHARACTERISTICS OF
ALL WORK AND/OR EQUIPMENT SUPPLIED BY THE OWNER OR OTHERS PRIOR TO THE START OF RELATED
WORK WITH THE MANUFACTURER OR SUPPLIER.
29.MANUFACTURER'S NAME, TRADEMARK, LOGOS, ETC., SHALL NOT BE VISIBLE TO THE PUBLIC.
30.THE TENANT, WITHOUT INVALIDATING THE CONTRACT, MAY ORDER EXTRA WORK OR MAKE CHANGES BY
ALTERING, ADDING TO, OR DEDUCTING FROM THE WORK. THE CONTRACT SUM AND CLAIMS FOR
EXTENSION OF TIME SHALL BE ADJUSTED ACCORDINGLY. SUCH WORK SHALL BE OTHERWISE EXECUTED
UNDER THE CONDITIONS OF THE ORIGINAL CONTRACT.
31.ALL "EXISTING TO REMAIN", "EXISTING TO BE RELOCATED", AND/OR NEW ITEMS INSTALLED BY THE
CONTRACTOR, IN ADDITION TO BEING AMPLY PROTECTED THROUGHOUT THE PERIOD OF CONSTRUCTION,
SHALL BE THOROUGHLY CLEANED TO THE SATISFACTION OF MAD PRIOR TO BEING TURNED OVER TO THE
OWNER.
32.THE CONTRACTOR AGREES TO PAY ALL TRANSPORTATION CHARGES ON ALL MATERIAL AND EQUIPMENT TO
THE POINT OF USE AND SHALL BE RESPONSIBLE FOR ALL UNLOADING, CHECKING, AND STORING OF SAME
IN CONNECTION WITH THIS CONTRACT.
33.IF THE CONTRACTOR CLAIMS THAT ANY REVISION TO THE DRAWINGS INVOLVES EXTRA COST UNDER THIS
CONTRACT, HE SHALL GIVE WRITTEN NOTICE TO MAD WITHIN A REASONABLE TIME AFTER RECEIPT OF SUCH
INSTRUCTIONS AND IN ANY EVENT, BEFORE PROCEEDING TO EXECUTE THE WORK. THE PROCEDURE SHALL
THEN BE AS PROVIDED FOR IN THE AGREEMENT UNDER "CHANGES IN THE WORK". NO SUCH CLAIMS SHALL
BE VALID UNLESS SO MADE. UNLESS OTHERWISE AGREED, NO PAYMENT ON SUCH BILLS WILL BE MADE UNTIL
FINAL SETTLEMENT.
34.ALL CLAIMS FOR ADDITIONAL WORK WILL BE SUBMITTED IN WRITING FOR REVIEW BY MAD AND SHALL
INCLUDE A COMPLETE DESCRIPTION OF THE WORK, MATERIALS USED, ROOM NUMBER OF THE AREA OF
WORK, AND AUTHORIZATION UNDER WHICH THE WORK IS BEING PERFORMED. TOTAL COST OF THE WORK,
INCLUDING THE CONTRACTOR'S MARK-UP, SHALL BE INCLUDED IN THE SUBMITTAL.
35.THE CONTRACTOR SHALL PROVIDE BLOCKING, BACKING, FRAMING HANGERS, OR OTHER SUPPORT FOR ALL
FIXTURES, EQUIPMENT, CABINETRY, FURNISHINGS, AND ALL OTHER ITEMS AS REQUIRED.
36.MAXIMUM ROOM OCCUPANT LOAD SIGNS SHALL BE FURNISHED AND INSTALLED AS REQUIRED BY THE LOCAL
GOVERNING BUILDING CODE.
37.AT THE TIME OF BID SUBMITTAL, THE CONTRACTOR SHALL ADVISE MAD, IN WRITING, OF ANY SPECIFIED
MATERIALS OR EQUIPMENT WHICH ARE EITHER UNAVAILABLE OR WILL CAUSE A DELAY IN THE COMPLETION
OF CONSTRUCTION.
38.THE CONTRACTOR SHALL PROVIDE AND INSTALL ROUGH PLUMBING AND FINAL HOOK-UP FOR ALL SPECIFIED
FIXTURES AND APPLIANCES AND SHALL SUPPLY ALL SUCH FIXTURES AND APPLIANCES, U.O.N.
39.PRIOR TO INSTALLATION OF CARPET AND WINDOW COVERING, THE CONTRACTOR SHALL MAINTAIN THE
SPACE IN BROOM CLEAN CONDITION WHETHER OR NOT SUCH INSTALLATION IS THE CONTRACTOR'S
RESPONSIBILITY.
40.THE CONTRACTOR SHALL PROVIDE ALLOWANCE FOR APPLIANCES, U.O.N.
41.THE CONTRACTOR SHALL LEAVE THE BUILDING IN A LOCKABLE CONDITION DURING THE PERIOD OF THIS
WORK WHEN THE CONTRACTOR'S WORKMEN ARE NOT PRESENT AT THE JOB SITE.
42.THE CONTRACTOR SHALL DEACTIVATE ALL UTILITY LINES IN CONTRACT AREA PRIOR TO START OF WORK AS
NECESSARY, AFTER SECURING OWNER'S PERMISSION.
43.THE CONTRACTOR SHALL PATCH, REPAIR, REPLACE, AND/OR REFINISH EXISTING CONSTRUCTION AS
NECESSARY TO REFURBISH THE AREA OF WORK.
44.ANY AND ALL PROPOSED REVISIONS SHALL BE SUBMITTED IN THE FORM OF A WRITTEN CHANGE ORDER TO
BE APPROVED AND AUTHORIZED BY MAD AND THE OWNER PRIOR TO START OF PROPOSED WORK.
45.THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL LIFE SAFETY EQUIPMENT AS REQUIRED BY
STATE AND LOCAL BUILDING CODES.
46.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF THE FIRE SPRINKLER
CONTRACTOR, WHO SHALL DESIGN AND PROVIDE CERTIFIED SPRINKLER DRAWINGS FOR MAD'S APPROVAL.
47.THE CONTRACTOR SHALL HOLD HARMLESS THE TENANT, BUILDING OWNER, MAD, AND THEIR
REPRESENTATIVES OF ANY LEGAL ACTION ARISING AS A RESULT OF THE CONTRACTOR'S WORK.
48.DAMAGE TO WORK SHALL BE REPAIRED BY THE TRADE WHOSE WORK IS DAMAGED AND CHARGED TO THE
PARTY RESPONSIBLE FOR THE DAMAGE.
49.THE GENERAL CONTRACTOR SHALL PROVIDE ALL FLOOR CUTOUTS AND PATCHING REQUIRED FOR
INSTALLATION OF ALL WORK.
50.CONTRACTOR TO INFORM MAD WHEN CHALKLINE LAYOUT OF PARTITIONS IS COMPLETED SO THAT IT CAN
BE VERIFIED AND ANY REQUIRED CHANGES MADE PRIOR TO CONSTRUCTION.
51.ALL PLUMBING FIXTURES SHALL BE SUPPLIED AND INSTALLED BY PLUMBING CONTRACTOR. GENERAL
CONTRACTOR SHALL COORDINATE SUPPLY OF ALL NECESSARY INFORMATION ON REQUIRED CUTOUTS TO
MILLWORK CONTRACTOR.
52.ALL MATERIALS AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE
ACCEPTANCE OF THE PROJECT BY THE OWNER, UNLESS STATED OTHERWISE.
53.CONTRACTOR SHALL PROVIDE SUBMITALS AS ELECTRONIC FILE (PDF PREFERRED, OR U.O.N.) TO MAD FOR
DESIGN APPROVAL AFTER HE HAS REVIEWED THEM FOR CONSTRUCTIBILITY, COORDINATION BETWEEN
TRADES, AND CONFORMANCE WITH THE CONTRACT DOCUMENTS.
54.THE CONTRACTOR SHALL SUBMIT (3) SAMPLES OF FINISH MATERIALS, FIXTURES AND EQUIPMENT TO MAD FOR
APPROVAL PRIOR TO INSTALLATION. THE CONTRACTOR SHALL BE WHOLLY LIABLE IF HE FAILS TO DO SO,
WHETHER MATERIALS ARE SPECIFIED CORRECTLY OR INCORRECTLY IN THE CONTRACT DOCUMENTS.
55.PROVIDE LIST OF ALL SUBMITTALS WITH SCHEDULE FOR TIMELY REVIEW OR RE-SELECTION IF REQUIRED. A
MINIMUM OF ONE (1) WEEK TIME FRAME FOR REVIEW OF ANY SUBMITTAL IS REQUIRED, UNLESS
ARRANGEMENTS FOR EXPEDITED REVIEW WITH MAD IS ACCEPTED.
56.GC SHALL SUBMIT THE LIGHTING PACKAGE TO MAD FOR REVIEW WITHIN THE FIRST TWO WEEKS AFTER
CONTRACT HAS BEEN AWARDED TO ENSURE SUFFICIENT TIME FOR REVIEW. A MINIMUM OF ONE (1) WEEK
TIME FRAME FOR REVIEW OF LIGHTING PACKAGE SUBMITTAL IS REQUIRED, UNLESS ARRANGEMENTS FOR
EXPEDITED REVIEW WITH MAD IS ACCEPTED.
57.BEFORE ACCEPTANCE BY THE OWNER, THE COMPLETED CONSTRUCTION SHALL BE CLEANED, LABELS
REMOVED, AND ALL OTHER TOUCH UP COMPLETED.
58.CONTRACT CLOSE-OUT SHALL OCCUR ONLY AFTER MAD HAS PREPARED THE CERTIFICATE OF SUBSTANTIAL
COMPLETION AND PUNCH LIST, AND PUNCH LIST ITEMS HAVE BEEN CORRECTED. THE CONTRACTOR SHALL
SUBMIT MAINTENANCE AND WARRANTY MANUALS, RELEASE OF LIENS, AND RECORD DRAWINGS TO MAD
WITH HIS FINAL APPLICATION FOR PAYMENT. MAD SHALL PREPARE ANY NECESSARY CHANGE ORDERS
REQUIRED TO FINALIZE THE COST OF THE PROJECT BASED ON THE CONTRACTOR'S FINAL SUBMITTALS.
GENERAL PARTITION NOTES
1.THE CONTRACTOR SHALL FURNISH AND INSTALL ALL PARTITIONS INDICATED ON THE DRAWINGS.
2.VERIFY ALIGNMENTS IN FIELD. NOTIFY MAD IMMEDIATELY IF MISALIGNMENT OF EXISTING ELEMENTS SHOULD
OCCUR.
3.THE CONTRACTOR SHALL USE CORNER BEADS AT ALL EXPOSED CORNERS AND EXPOSED ENDS IN PLASTER
AND DRYWALL PARTITIONS.
4.ALL PARTITIONS SHALL BE ANCHORED PER MANUFACTURERS' SPECIFICATIONS AND AS REQUIRED BY
APPLICABLE BUILDING CODES.
5.BRING TO THE ATTENTION OF MAD ANY FIELD CONDITIONS THAT DO NOT ALLOW CONSTRUCTION OR
INSTALLATION AS DRAWN.
6.NOTE ANY BASE BUILDING DEFICIENCIES BEFORE THE START OF CONSTRUCTION TO MAD.
7.MAD SHALL HAVE THE RIGHT TO REVIEW AND APPROVE CHALK LINES PRIOR TO INSTALLATION OF TRACKS.
MAD SHALL BE NOTIFIED OF ANY DEVIATION FROM DIMENSIONS OR CLEARANCES INDICATED ON PLANS
REQUIRED DUE TO FIELD CONDITION.
8.THE CONTRACTOR SHALL SUPPLY ALL RETURN AIR OPENINGS IN SLAB TO SLAB PARTITIONS ABOVE CEILINGS
AS REQUIRED BY ENGINEERING DRAWINGS. ALL OPENINGS IN DEMISING AND SOUND-ATTENUATED
PARTITIONS SHALL HAVE SOUND BOOTS AND ALL OPENINGS IN FIRE-RATED PARTITIONS SHALL HAVE FIRE
DAMPERS AS REQUIRED BY LOCAL BUILDING CODES. CONTRACTOR SHALL COORDINATE WITH
ENGINEERING DRAWINGS AND INFORM MAD OF DISCREPANCIES PRIOR TO BIDDING.
9.THE CONTRACTOR SHALL PROVIDE SUFFICIENT FRAMING IN PARTITIONS TO ACCOMMODATE ALL DUCT
WORK. RETURN AIR OPENINGS AND GRILLS ABOVE AND BELOW CEILINGS SHALL BE COORDINATED WITH
MECHANICAL ENGINEERING DRAWINGS AND MECHANICAL CONTRACTOR'S SHOP DRAWINGS. ALL
OPENINGS SHALL BE PROPERLY SEALED FOR SOUNDPROOFING AND AGAINST VIBRATION.
10.THE CONTRACTOR SHALL PROVIDE AND INSTALL ACCESS PANELS AS REQUIRED FOR MECHANICAL,
ELECTRICAL, AND PLUMBING INSTALLATIONS PER APPLICABLE BUILDING CODES. CONTRACTOR SHALL
COORDINATE TYPE AND LOCATION OF ACCESS PANELS WITH MAD PRIOR TO INSTALLATION.
11.THE GENERAL CONTRACTOR SHALL COORDINATE ALL PLUMBING ROUGH-INS, FIXTURES AND ACCESSORIES
INDICATED IN THE DRAWINGS.
12.THE GENERAL CONTRACTOR SHALL COORDINATE ALL VALVES AS INDICATED IN THE DRAWINGS AND/OR AS
REQUIRED FOR THE PROPER CONTROL OF THE PIPING AND APPARATUS INSTALLED AS PART OF THIS PROJECT
SO THAT ANY FIXTURE, LINE OR APPARATUS MAY BE CUT OFF AND REPAIRED WITHOUT INTERFERENCE OR
INTERRUPTION OF SERVICE TO THE REMAINDER OF THE BUILDING.
13.ALL PIPING SHALL BE TESTED AND INSPECTED AS REQUIRED BY THE AUTHORITIES HAVING JURISDICTION,
BEFORE CLOSING OR CONCEALING IN PARTITIONS.
14.GENERAL CONTRACTOR SHALL COORDINATE WITH MILLWORK CONTRACTOR/FURNITURE MANUFACTURER
FOR EXACT STUD LOCATIONS AND HEIGHTS OF MILLWORK AND FURNITURE BACKING PRIOR TO
INSTALLATION OF GYPSUM BOARD.
15.IF OUTLETS ARE INSTALLED DIRECTLY INTO CORE WALLS, SEAL/INSULATE AS REQUIRED PER CODES TO
MAINTAIN THE INTEGRITY OF WALL RATING. REFER TO POWER AND SIGNAL PLAN FOR LOCATIONS.
16.PATCH/REPAIR ALL EXISTING TO REMAIN PARTITIONS, TO RECEIVE A NEW FINISH.
17.INSTALL FIRE DAMPERS IN ALL DUCTS PENETRATING RATED CORRIDOR WALLS AND/OR CEILINGS. DAMPERS
ARE TO COMPLY WITH LOCAL MUNICIPAL CODES.
18.IN SOUND RATED ROOMS, ALL WALL AND FLOOR PENETRATIONS FOR PIPES, DUCTS AND OUTLETS SHALL BE
SEALED WITH AN ACOUSTICAL SEALANT AND CONCEALED OR RECESSED FIXTURES SHALL BE COVERED OR
BACKED WITH A SOUND ATTENUATION BLANKET.
19.PROVIDE WATER RESISTANT GYPSUM BOARD IN ALL TOILETS AND SHOWER ROOMS.
20.INSTALL COMBINATION FIRE/SMOKE DAMPERS AT ALL DUCTS PENETRATING RATED CORRIDOR WALL(S)
AND/OR CEILING(S). DAMPERS SHALL COMPLY WITH CBC CHAPTER 7.
21.THE GENERAL CONTRACTOR SHALL VERIFY THE MANUFACTURER OF ALL EXISTING INTERIOR BUILDING
ELEMENTS BUT NOT LIMITED TO DOOR FRAMES, DOORS, DOOR HARDWARE, FIRE EXTINGUISHER CABINETS,
MILLWORK FINISHES, AND MILLWORK HARDWARE.
22.WHEN NEW INTERIOR BUILDING ELEMENTS ARE TO MATCH EXISTING THE GENERAL CONTRACTOR SHALL
SUBMIT SAMPLES OF PROPOSED NEW AND EXISTING ELEMENTS FOR REVIEW AND APPROVAL PRIOR TO
COMMENCEMENT OF INSTALLATION OF SUCH ELEMENTS.
23.GYPSUM BOARD NOTES:
a.ALL GYPSUM BOARD SHEETS TO RUN VERTICALLY.
b.TAPE OUTER JOINTS OF GYPSUM BOARD ONLY.
c.NO JOINTS EXCEPT AT STUDS.
d.DRYWALL SCREW EDGE AND FIELD SPACING PER GYPSUM BOARD MANUFACTURERS' RECOMMENDATIONS.
e.ALL SCREWS SHALL ENGAGE STUDS, MINIMUM CSTC 40-44.
f.FIBERGLASS BATT INSULATION SHALL BE OWENS/CORNING FIBERGLASS NOISE BARRIER BATTS, OCF
FRICTION FIT OR APPROVED EQUAL. FIBERGLASS THICKNESS TO EQUAL STUD DEPTH.
g.STAGGER JOINTS OF GYPSUM BOARD WHERE MULTIPLE LAYERS OCCUR.
h.DO NOT GLUE MULTIPLE LAYERS OF GYPSUM BOARD TOGETHER.
i.NO MECHANICAL TIES BETWEEN OPPOSITE SIDES OF PARTITION.
j.ALL GYPSUM BOARD SHALL BE 5/8" TYPE "X" UNLESS OTHERWISE NOTED ON PLANS.
k.TAPE, BED, AND SAND SMOOTH ALL CORNERS AND JOINTS TO RECEIVE WALL FINISH.
GENERAL POWER & DATA NOTES
1.THE CONTRACTOR SHALL FURNISH AND INSTALL ALL LIGHT FIXTURES AND ELECTRICAL WORK AS SHOWN OR
IMPLIED IN DRAWINGS AND NOTES.
2.ALL LIGHT SWITCHES SHALL BE CIRCUITED AND INSTALLED TO COMPLY WITH APPLICABLE LOCAL CODES AND
STATE ENERGY REQUIREMENT.
3.THE MECHANICAL AND ELECTRICAL DRAWINGS ARE SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. IT
IS THE CONTRACTOR'S RESPONSIBILITY TO CHECK DRAWINGS FOR COORDINATION PRIOR TO BIDDING AND
AGAIN PRIOR TO INSTALLATION OF MECHANICAL AND ELECTRICAL WORK. ANY DISCREPANCY BETWEEN THE
DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF MAD FOR CLARIFICATION. WORK INSTALLED IN
CONFLICT WITH MAD'S DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR AT THE CONTRACTOR'S
EXPENSE AND SHALL NOT IMPACT THE SCHEDULE.
4.REFER TO ENGINEERING DRAWINGS FOR CIRCUITING AND EXACT SPECIFICATIONS. MECHANICAL AND
ELECTRICAL ENGINEERS' DRAWINGS ARE NOT INTENDED TO INDICATE EXACT LOCATIONS OF FIXTURES OR
EQUIPMENT. REFER TO MAD'S DRAWINGS FOR LOCATIONS OF FIXTURES, OUTLETS AND EQUIPMENT.
5.VERIFY COMMUNICATIONS REQUIREMENTS AND RACKS, RISERS, CIRCUITING, ETC. WITH APPROPRIATE
CONSULTANT DRAWINGS. PROVIDE BACK BOX WITH BLANK COVER PLATE AND CONDUIT STUB-UP TO
CEILING FOR CARD READERS. VERIFY SIZE AND LOCATION OF BACK BOX AND CONDUIT.
6.GENERAL CONTRACTOR TO COORDINATE ALL NEW SECURITY SYSTEM WORK WITH TENANT'S SECURITY
VENDER & ELECTRICAL ENGINEER DRAWINGS. CONTRACTOR TO PROVIDE ALL CONDUITS AND POWER AS
REQUIRED. CONTRACTOR TO ALSO VERIFY LOCATION OF SECURITY MONITORING SYSTEM PRIOR TO
INSTALLATION. NOTIFY MAD OF ANY CONFLICTS BETWEEN DRAWINGS PRIOR TO ORDERING OR INSTALLING
MATERIALS.
7.REFER TO MAD'S DRAWINGS FOR EXACT SPECIFICATIONS AND LOCATIONS OF FIXTURES, OUTLETS AND
EQUIPMENT.
8.REFER TO ELECTRICAL ENGINEER DRAWINGS FOR ADDITIONAL EQUIPMENT/DEVICE REQUIREMENTS.
9.THE GC SHALL BE RESPONSIBLE FOR VERIFYING THE EQUIPMENT'S ENVIRONMENTAL & ELECTRICAL
REQUIREMENTS.
10.CONTRACTOR SHALL VERIFY QUANTITY AND LOCATION OF EXISTING OUTLETS SHOWN TO REMAIN. ADVISE
MAD OF ANY CONFLICTS PRIOR TO CONSTRUCTION.
11.THE CONTRACTOR SHALL COORDINATE HIS WORK WITH MANUFACTURERS' SPECIFICATIONS AND
REQUIREMENTS.
12.THE WORK SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL
BOARD OF FIRE UNDERWRITERS, PUBLIC UTILITIES COMPANY, OWNER'S AND LANDLORD'S
COMMUNICATIONS COMPANY, AND ALL OTHER AUTHORITIES HAVING JURISDICTION.
13.ALL NEW MATERIALS REQUIRED SHALL CONFORM TO THE STANDARDS OF UNDERWRITERS' LABORATORIES,
INC. IN EVERY CASE WHERE SUCH A STANDARD HAS BEEN ESTABLISHED, U.O.N.
14.GENERAL CONTRACTOR TO COORDINATE SECURING OF PERMITS FOR LOW VOLTAGE WIRING.
15.GENERAL CONTRACTOR TO COORDINATE SECURING OF PERMITS FOR FIRE/LIFE SAFETY DEVICES.
16.THE CONTRACTOR SHALL FURNISH, INSTALL, AND COORDINATE ANY ELECTRICAL AND/OR LIGHTING ITEMS
WITH CABINET WORK AS REQUIRED, U.O.N.
17.THE CONTRACTOR SHALL COORDINATE ANY COMMUNICATIONS/DATA & AV REQUIREMENTS WITH THE
OWNER'S IT/AV CONTRACTOR AS REQUIRED.
18.THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY ELECTRICAL SERVICE AND LIGHTING FOR ALL TRADES AS
REQUIRED.
19.PROVIDE COMMUNICATIONS/DATA/AV OUTLETS AND ALL NECESSARY CONDUIT RUNS AS SHOWN ON
POWER AND DATA PLANS.
20.PROVIDE SLEEVES IN RATED PARTITIONS ABOVE CEILING FOR COMMUNICATIONS/DATA. VERIFY THE SIZE OF
REQUIRED CONDUITS WITH COMMUNICATIONS/DATA CONTRACTOR AND TENANT PRIOR TO START OF
WORK.
21.ALL POWER, COMMUNICATIONS/DATA, AND AV CONDUIT SHALL BE CONCEALED IN PARTITIONS AND/OR
CEILINGS.
22.PROVIDE METER, METER LOOP, AND SERVICE IN ACCORDANCE WITH LOCAL AND ELECTRICAL RUNS AS THEY
OCCUR.
23.PROVIDE POWER DISTRIBUTION TO ALL LIGHTING AND EQUIPMENT.
24.PROVIDE SERVICE AND CONNECTIONS FOR HVAC EQUIPMENT AND CONTROLS.
25.PROVIDE ALL PANELS, CUTTERS AND DISCONNECTS.
26.PROVIDE PANEL COMPLETE WITH TYPEWRITTEN DIRECTORY AND SPLIT BARS FOR TIME-CONTROLLED
CIRCUITS.
27.COORDINATE CONTROL WIRING WITH HVAC CONTRACTOR.
28.PROVIDE SERVICE, OUTLETS, OR CONNECTION AS REQUIRED FOR FIXTURES AND/OR EQUIPMENT FURNISHED
AND INSTALLED BY OTHERS.
29.ALL NEW COMMUNICATIONS AND/OR DATA CONDUIT SHALL BE 3/4"Ø STUB UP 10" ABOVE PARTITION WITH
90 DEGREE SWEEP TO PLENUM SPACE. PROVIDE PLASTIC BUSHING AT STUB UP CONDUIT.
30.ALL NEW AV CONDUIT SHALL BE 1-1/4"Ø (U.O.N.) STUB UP 10" ABOVE PARTITION WITH 90 DEGREE SWEEP TO
PLENUM SPACE. PROVIDE PLASTIC BUSHING AT STUB UP CONDUIT.
28.ALL VOICE AND DATA WIRING SHALL BE PLENUM RATED. CONTRACTOR SHALL PROVIDE WALL BOX AND
CONDUIT FROM BOX TO CEILING PLENUM. CONDUIT SHALL HAVE PULL STRINGS. COORDINATE WITH
TENANTS VOICE/DATA CONSULTANT.
29.THE MINIMUM SIZE JUNCTION BOX FOR ALL WALL MOUNTED OUTLETS SHALL BE 4S, DEEP. THIS SHALL
INCLUDE, BUT NOT BE LIMITED TO ELECTRICAL, PHONE/DATA, AUDIO/VISUAL AND SECURITY. REFER TO
ELECTRICAL ENGINEER'S DRAWINGS.
30.JUNCTION BOXES AT ALL ACOUSTICAL PARTITION SHALL RECEIVE 'LOWRY' OR APPROVED EQUAL, BOX PADS
(MIN. 1/8" THICK, PERMANENTLY RESILIENT MATERIAL) ALL HOLES IN JUNCTION BOXES SHALL BE COMPLETELY
COVERED WITH PADS, MOLDED AND PRESSED ONTO THE BACK AND SIDES OF BOX.
31.PROVIDE EXTENSION RING AT FIRE ALARM BOXES & WALL OUTLETS ALONG CORE WALLS WHEREVER FURRED
PARTITIONS & FABRIC-WRAPPED/TACKABLE WALL SURFACES OCCUR. REFER TO ELEVATIONS & FINISH PLAN(S)
FOR LOCATIONS OF THESE CONDITIONS.
32.THE GC SHALL SUBMIT, FOR DESIGNER'S APPROVAL, SAMPLES OF ALL SWITCHES, ELEC, COMMUNICATIONS &
DATA OUTLETS & ANY OTHER ELECTRICAL DEVICES THAT ARE TO BE SURFACE-MOUNTED ON THE PROJECT
(INCLUDING SUBCONTRACTOR DEVICES) PRIOR TO INSTALLATION.
33.THE GC SHALL SUBMIT TO MAD FOR APPROVAL, PLANS INDICATING LOCATIONS OF SURFACE-MOUNTED
FIRE/LIFE SAFETY DEVICES, INCLUDING STROBE LIGHTS, PRIOR TO INSTALLATION.
GENERAL DEMOLITION NOTES
1.THE GENERAL CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIAL AS REQUIRED TO COMPLETE
DEMOLITION AND REMOVAL OF ALL ITEMS AS INDICATED ON PLANS OR AS OTHERWISE DIRECTED BY
OWNER/TENANT.
2.THE GENERAL CONTRACTOR SHALL EXECUTE ALL WORK WITHIN THE REGULATIONS OF THE BUILDING FOR
DEMOLITION AND REMOVAL OF DEBRIS, INCLUDING OVERTIME WORK REQUIRED.
3.PRIOR TO FINAL BID SUBMITTAL, THE GENERAL CONTRACTOR SHALL VERIFY IF ANY EXISTING PIPING, HVAC OR
ANY OTHER BUILDING SYSTEM COMPONENTS NEED TO BE RELOCATED IN ORDER TO ACCOMMODATE THE
PROPOSED DESIGN. IF SO, SUCH MODIFICATIONS ARE TO BE IDENTIFIED IN THE BID AND PRESENTED TO
THE CLIENT/DESIGNER TO ACCEPT OR REJECT. CHANGE ORDERS FOR THESE KINDS OF MODIFICATIONS
WILL NOT BE ACCEPTED DURING CONSTRUCTION.
4.PRIOR TO FINAL BID SUBMITTAL, THE GENERAL CONTRACTOR SHALL VERIFY IF THE EXISTING CEILING SYSTEM
NEEDS TO BE UPGRADED TO COMPLY WITH LOCAL BUILDING AND SEISMIC CODES. IF SO, THIS SHALL BE
INCLUDED IN THE BID/BASE SCOPE OF WORK. CHANGE ORDERS FOR THIS MODIFICATION WILL NOT BE
ACCEPTED DURING CONSTRUCTION.
5.ALL DEMOLITION AND CONSTRUCTION SHALL BE PERFORMED DURING HOURS DETERMINED BY LANDLORD.
(MAY REQUIRE WORK BE PERFORMED AFTER HOURS AND DURING WEEKEND). THE GENERAL CONTRACTOR
SHALL PREPARE SCHEDULE OF PHASES AND TIME OF PERFORMANCE FOR OWNER/TENANT AND CLIENT'S
REVIEW AT BID SUBMITTAL.
6.GENERAL CONTRACTOR SHALL CONTACT LANDLORD IN ADVANCE TO ARRANGE WHERE STOCK CAN BE
MOVED/STORED.
7.THE GENERAL CONTRACTOR SHALL AT ALL TIMES PROTECT THE PROPERTY OF THE BUILDING OWNER,
INCLUDING BUT NOT LIMITED TO, WINDOWS, MULLIONS, ELECTRICAL AND AIR CONDITIONING
EQUIPMENT, CONVECTOR ENCLOSURES, ETC. COLUMNS, FLOORS AND CEILING TILES, PUBLIC TOILETS,
ELEVATORS, DOORS, BUCKS.
8.THE GENERAL CONTRACTOR SHALL DO ALL CUTTING, FITTING AND PATCHING WORK THAT MAY BE
REQUIRED TO MAKE ALL PARTS COME TOGETHER PROPERLY, AND FIT TO RECEIVE OR BE RECEIVED BY WORK
OF OTHER CONTRACTORS SHOWN UPON OR REASONABLY IMPLIED BY THE DRAWINGS AND NOTES.
9.CONTRACTOR SHALL PROVIDE ALL SUPPORTS AND SEISMIC BRACING REQUIRED FOR EXISTING BUILDING
ELEMENTS THAT ARE TO REMAIN (DUCTS, PIPES, ACOUSTICAL CEILING HANGER WIRES, LIGHT FIXTURES,
CONDUITS, SPRINKLER LINES, ETC.).
10.ALL WORK DEMOLISHED SHALL BE REMOVED FROM THE PREMISES EXCEPT ITEMS TO BE RE-USED OR
RETURNED TO TENANT OR AS OTHERWISE NOTED.
11.THE GENERAL CONTRACTOR SHALL REMOVE FROM PREMISES CONDUITS LEFT AFTER WALL DEMOLITION,
INCLUDING SWITCH BOXES, PLATES, BRIDGES, OR ANY OTHER TELEPHONE OR ELECTRICAL WIRING AND
EQUIPMENT. U.O.N.
12.THE GENERAL CONTRACTOR SHALL FURNISH A SYSTEM OF TEMPORARY LIGHTS THROUGHOUT THE SPACE
UNDER CONSTRUCTION AS REQUIRED.
13.THE GENERAL CONTRACTOR SHALL CAP AND FLUSH OFF BEHIND FINISH SURFACES ALL PROJECTING
PLUMBING, FLOOR ELECTRICAL/TELEPHONE OUTLETS, AND ALL OTHER PROJECTING ITEMS WHICH ARE BEING
ABANDONED.
14.TERMINATE AND PATCH ALL ABANDONED/UNUSED ELECTRICAL, DATA/TELEPHONE OUTLETS, THERMOSTATS
AND LIGHT SWITCHES AS NOTED ON PLANS.
15.PIPES AND CONDUIT ENCOUNTERED IN DEMOLISHED PARTITIONS AND AREAS WHICH ARE TO REMAIN IN USE
SHALL BE RE-ROUTED AND CONCEALED. THOSE WHICH ARE TO BE ABANDONED SHALL BE CAPPED AND
CONCEALED IN FLOOR, WALL OR CEILING.
16.UPON COMPLETION OF THE DEMOLITION WORK, THE GENERAL CONTRACTOR SHALL PROVIDE THAT ALL
AREAS BE LEFT BROOM CLEAN.
Sheet Title:
ISSUE DATE
ISSUE FOR PLANCHECK 12.22.2025
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ENGINEER/CONSULTANT
ARCHITECT/ENGINEER STAMP
30
5
W
4
T
H
S
T
R
E
E
T
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
1
CA
F
E
OA
S
I
S
CLIENT
www.madstudiola.com
CITY STAMP
Project Director:
Project Designer:
Project Tech:
Project No:25030.300E.M.
E.M.
S.P.
ISSUED FOR MEP 01.13.2026
ISSUED FOR PLAN CHECK COMMENTS- PLANNING DEPT.01.22.2026
ISSUED FOR PRICING 02.17.2026
ISSUED FOR PLAN CHECK COMMENTS - PLANNING DEPT.02.20.2026
ISSUED FOR COUNTY REVIEW 03.24.2026
ISSUED FOR ADDENDUM A 03.27.2026
ISSUED FOR BUILDING DEPT REVIEW 04.08.2026
ISSUED FOR BUILDING DEPT REVIEW - RESUBMITTAL 05.05.2026
ISSUED FOR BUILDING DEPT CORRECTIONS 05.20.2026
ID0.1
GENERAL NOTES
GENERAL REFLECTED CEILING PLAN NOTES
1.THE CONTRACTOR SHALL FURNISH AND INSTALL ALL LIGHT FIXTURES AND ELECTRICAL WORK AS SHOWN OR
IMPLIED IN DRAWINGS AND NOTES.
2.THE MECHANICAL AND ELECTRICAL DRAWINGS ARE SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. IT
IS THE CONTRACTOR'S RESPONSIBILITY TO CHECK DRAWINGS FOR COORDINATION PRIOR TO BIDDING AND
AGAIN PRIOR TO INSTALLATION OF MECHANICAL AND ELECTRICAL WORK. ANY DISCREPANCY BETWEEN THE
DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF MAD FOR CLARIFICATION. WORK INSTALLED IN
CONFLICT WITH MAD'S DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR AT THE CONTRACTOR'S
EXPENSE AND SHALL NOT IMPACT THE SCHEDULE.
3.CEILING HEIGHTS AND DETAILING SHALL BE AS INDICATED IN DRAWINGS. ANY DEVIATION FROM HEIGHT OR
DETAILING INDICATED SHALL BE SUBMITTED TO MAD FOR REVIEW PRIOR TO BIDDING.
4.REFER TO PLAN FOR ALL CEILING HEIGHTS. GENERAL CONTRACTOR SHALL VERIFY CLEARANCES BETWEEN
DUCTWORK, LIGHT FIXTURES, AND OTHER OBSTRUCTIONS IN THE CEILING PLENUM TO ASSURE THE FINISH
CEILING HEIGHT.
5.FOR DETAILS AND SPECIFICATIONS OF LIGHTING FIXTURES, SWITCHES, PANEL BOXES, DIMMER CONTROLS,
CIRCUITING, AIR CIRCUITING, AIR CONDITIONING, DUCTWORK AIR SUPPLY DIFFUSERS, AIR RETURN GRILLES,
JUMP DUCT, THERMOSTATS, SMOKE DETECTORS, ETC., SEE ELECTRICAL AND MECHANICAL DRAWINGS.
6.THE CEILING WORK SHALL BE CLOSELY COORDINATED WITH THAT OF OTHER TRADES WHEREVER IT IS
CONTIGUOUS.
7.GENERAL CONTRACTOR SHALL ENSURE COMPLIANCE WITH CURRENT TITLE 24.
8.GENERAL CONTRACTOR TO RE-CIRCUIT/RE-SWITCH ALL LIGHTING AS REQUIRED TO COMPLY WITH NEW
DESIGN AND LOCAL CODES. SWITCHING OF ALL OFFICES/ENCLOSED ROOMS SHALL COMPLY WITH TITLE 24
REQUIREMENTS.
9.GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING FIELD CONDITIONS AND DIMENSIONS AND NOTIFY MAD
OF ANY DISCREPANCIES ADVERSELY AFFECTING THE LIGHTING DESIGN AND/OR INSTALLATION (INCLUDING
CONFLICTS WITH STRUCTURE, MECHANICAL EQUIPMENT, DUCTWORK, ETC.) PRIOR TO PROCEEDING WITH
THE WORK.
10.FASCIAS OR ANY OTHER TRANSITION IN CEILING HEIGHT CREATED BY THE INSTALLATION AND/OR
ALTERATION OF HVAC DUCTS, PIPING, OR OTHER EQUIPMENT SHALL BE CONSTRUCTED OF GYPSUM BOARD
ON METAL FRAMING.
11.ALL JOINTS IN THE CEILING TILE FIELD SHALL BE SQUARE, LEVEL, AND PERFECTLY ALIGNED WITH EACH OTHER
AND WITH RECESSED LIGHT FIXTURES.
12.THE GENERAL CONTRACTOR SHALL PROVIDE CUTOUTS AND OTHER SPECIAL PROVISIONS IN ACOUSTICAL
CEILING TILE AS REQUIRED FOR LIGHT FIXTURES, REGISTERS, DIFFUSERS AND OTHER INSERTED ITEMS.
13.THE GENERAL CONTRACTOR SHALL REPAIR AND/OR REPLACE ANY DAMAGED CEILING TILES WHICH ARE
REMOVED TO FACILITATE PLENUM SYSTEMS INSTALLATIONS.
14.PRIOR TO CLOSING CEILINGS, PLENUM SYSTEMS (HVAC, PLUMBING, ELECTRICAL, ETC.) SHALL BE INSPECTED
AND TESTED AS REQUIRED BY CONTRACTOR'S ENGINEER AND BY AUTHORITIES HAVING JURISDICTION TO
ENSURE PROPER INSTALLATION AND FUNCTION.
15.THE GENERAL CONTRACTOR SHALL NOT BE REQUIRED TO OPEN ANY CEILINGS FOR TELEPHONE, SECURITY,
OR COMPUTER DATA SYSTEMS INSTALLATION, REPAIR, OR RECONFIGURATION AFTER CEILINGS ARE CLOSED.
IF SUCH WORK IS REQUIRED, THE EXPENSE TO REOPEN CEILINGS SHALL BE BORNE BY THE PARTY
RESPONSIBLE.
16.THE GENERAL CONTRACTOR SHALL FURNISH AND INSTALL NEW LIGHT FIXTURES (COMPLETE WITH LAMPS) OF
TYPES AND MANUFACTURERS SPECIFIED.
17.WHEN NOTED ON THE DRAWINGS TO REMOVE & RELOCATE EXISTING LIGHT FIXTURES, THEY SHALL BE
REFURBISHED, CLEANED, AND RELAMPED AS REQUIRED.
18.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD SUPERVISION OF ALL MECHANICAL WORK
DURING INSTALLATION AND SHALL INSPECT ALL SYSTEMS FOR OPERATION AND CODE COMPLIANCE AT
COMPLETION OF THE JOB.
19.LOCATE NEW DIFFUSERS TO ALIGN WITH NEW FIXTURE PATTERNS. COORDINATE DIFFUSER INSTALLATION TO
AVOID CONFLICT WITH WORK OF OTHER TRADES IN PLENUM.
20.WHEN NOTED FOR EXISTING DIFFUSERS TO BE REMOVED & RELOCATED, THEY SHALL BE CLEANED AND
REFURBISHED AS REQUIRED. COORDINATE DIFFUSER INSTALLATION TO AVOID CONFLICT WITH WORK OF
OTHER TRADES IN PLENUM.
21.LOCATE HVAC GRILLES TO MINIMIZE SOUND TRAVEL FROM AREA TO AREA. NOTIFY MAD OF ANY
ANTICIPATED ACOUSTICAL PROBLEMS BEFORE START OF WORK.
22.ALLOWANCE SHALL BE MADE FOR LATERAL MOVEMENT OF THE SYSTEM. MAIN RUNNERS AND CROSS
RUNNERS SHALL BE ATTACHED AT TWO ADJACENT WALLS WITH CLEARANCE BETWEEN THE WALL AND THE
RUNNERS MAINTAINED AT THE OTHER TWO WALLS. REFER TO DETAILS ON SHEET ID5.2.
23.INSTALL SUPPORT WIRES AND CROSS RUNNERS TO AVOID CONTACT WITH HVAC EQUIPMENT AND
DUCTWORK.
24.THE GENERAL CONTRACTOR SHALL COORDINATE FIRE/LIFE SAFETY PERMITS WITH THE BUILDING'S FIRE/LIFE
SAFETY CONTRACTOR AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BETWEEN THE FIRE/LIFE SAFETY
SYSTEM REQUIREMENTS AND THE PLANS.
25.FIRE SPRINKLERS - PROVIDE COMPLETE SYSTEM INCLUDING, BUT NOT LIMITED TO, PIPING, VALVES, SPRINKLER
DROPS, AND SPRINKLER HEADS. USE REFLECTED CEILING PLANS FOR LAYOUT GUIDELINES. ALL SPRINKLER
HEADS SHALL BE FULLY RECESSED (FLUSH TO CEILING).
26.RE-WORK, RELOCATE, RETROFIT AND/OR INSTALL NEW FIRE/LIFE SAFETY ANNUNCIATION DEVICES AS
REQUIRED TO COMPLY WITH LOCAL GOVERNING CODES.
27.EXTEND OR MODIFY EXISTING AUTOMATIC FIRE EXTINGUISHING SYSTEM AS NEEDED, TO BE APPROVED BY
BUILDING AND SAFETY MECHANICAL PLAN CHECK PRIOR TO INSTALLATION.
28.FURNISH AND INSTALL SMOKE DETECTORS PER ELECTRICAL ENGINEER'S DRAWINGS. LOCATION AND
QUANTITY OF SMOKE DETECTORS WITHIN TENANT SPACE SHALL BE DETERMINED BY THE FIRE MARSHAL.
29.WHERE CEILINGS ARE SPECIFIED TO BE OF FIRE-RATED CONSTRUCTION, ALL RECESSED LIGHT FIXTURES,
SPEAKERS, ETC. SHALL BE BOXED OUT ABOVE THE CEILING WITH A FIRE-RATED ENCLOSURE EQUAL TO THAT
OF THE CEILING.
30.GENERAL CONTRACTOR SHALL COORDINATE WORK TO ACCOMMODATE VARIATIONS IN CEILING HEIGHTS
AND EQUIPMENT INSTALLED THEREIN.
31.THE GENERAL CONTRACTOR SHALL VERIFY THAT SPRINKLER AND HVAC PLACEMENT COMPLIES WITH ALL
APPLICABLE LOCAL CODE REQUIREMENTS AND RE-WORK AS NECESSARY.
32.ALL SUSPENDED GYP. BD CEILINGS SHALL RECEIVE SKIM COAT. PREP FOR FLAT PAINT FINISH WITHOUT ANY
APPARENT SEAMS OR IMPERFECTIONS. UNLESS OTHERWISE NOTED, REFER TO REFLECTED CEILING PLAN AND
FINISH PLANS PAINT SPEC, FINISH AND LOCATION.
33.CEILING FIXTURES, TERMINALS, AND DEVICES:
a.ALL LIGHT FIXTURES, AIR TERMINALS/GRILLS, OR OTHER DEVICES (REFERRED TO ALL BY COMMON TERM
FIXTURES HEREAFTER) SHALL BE MOUNTED IN A MANNER THAT WILL NOT COMPROMISE CEILING
PERFORMANCE.
b.ALL FIXTURES SHALL BE SUPPORTED DIRECTLY BY MAIN RUNNERS OR BY SUPPLEMENTAL FRAMING WHICH IS
SUPPORTED BY MAIN RUNNERS AND POSITIVELY ATTACHED WITH SCREWS OR OTHER APPROVED
CONNECTORS.
c.SURFACE MOUNTED FIXTURES SHALL BE ATTACHED TO A MAIN RUNNER WITH A POSITIVE CLAMPING DEVICE
MADE OF MATERIAL WITH A MINIMUM OF 14 GAGE. ROTATIONAL SPRING CLAMPS DO NOT COMPLY.
d.ACCESS PANELS: ACCESS TO THE SPACE BETWEEN THE CEILING AND THE FLOOR OR ROOF ABOVE SHALL
NOT BE ALLOWED. SMALL ACCESS PANELS FOR THE INSPECTION, ADJUSTMENT, OR REPAIR OF UTILITY
SWITCHES, VALVES, SENSORS, ETC MAY BE ALLOWED IF THE PANEL IS LESS THAN 300 SQUARE INCHES. SUCH
PANELS SHALL ALSO HAVE PERMANENT WARNING LABEL AS FOLLOWS:
WARNING: 1. DO NOT CLIMB, WALK, OR CRAWL ON THE GYPSUM BOARD CEILING.
2. DO NOT STORE OR STOW ANYTHING ON THE GYPSUM BOARD CEILING.
e.ALL LIGHT FIXTURES WEIGHING LESS THAN OR EQUAL TO 10 LB. SHALL HAVE ONE NO. 12 GAUGE SAFETY
WIRE CONNECTED FROM FIXTURE HOUSING TO STRUCTURE ABOVE. IT IS NOT NECESSARY FOR THESE SAFETY
WIRES TO BE TAUT.
f.ALL FIXTURES WEIGHING GREATER THAN 10 LB. BUT LESS THAN OR EQUAL TO 56 LB. SHALL HAVE TWO NO. 12
GAUGE SAFETY WIRE CONNECTED FROM FIXTURE HOUSING TO STRUCTURE ABOVE. IT IS NOT NECESSARY
FOR THESE SAFETY WIRES TO BE TAUT.
g.ALL FIXTURES WEIGHING GREATER THAN 56 LB. SHALL BE SUPPORTED DIRECTLY FROM STRUCTURE ABOVE BY
APPROVED HANGERS.
h.PENDANT-HUNG FIXTURES SHALL BE SUPPORTED DIRECTLY FROM STRUCTURE ABOVE USING NO LESS THAN
NO. 9 GAUGE WIRE OR AN APPROVED ALTERNATE SUPPORT. THE CEILING SUSPENSION SYSTEM SHALL NOT
PROVIDE ANY DIRECT SUPPORT.
i.ALL RECESSED OR DROP-IN FIXTURES SHALL BE SUPPORTED DIRECTLY FROM FIXTURE HOUSING TO THE
STRUCTURE ABOVE WITH A MINIMUM OF TWO NO. 12 GAUGE WIRES LOCATED AT DIAGONALLY OPPOSITE
CORNERS. LEVELING OR POSITIONING OF FIXTURES MAY BE PROVIDED BY CEILING GRID. FIXTURE SUPPORT
WIRES MAY BE SLIGHTLY LOOSE TO ALLOW THE FIXTURE TO SEAT IN THE GRID SYSTEM. FIXTURES SHALL NOT
BE SUPPORTED FROM MAIN RUNNERS OR FURRING CHANNELS IF THE WEIGHT OF THE FIXTURES CAUSES
TOTAL LOAD TO EXCEED THE DEFLECTION CAPABILITY OF THE CEILING SUSPENSION SYSTEM.
j.PROVIDE A 2-INCH OVERSIZED RING, ADAPTER OR SLEEVE ON SPRINKLER AND SIMILAR PENETRATIONS TO
ALLOW FOR A 1-INCH HORIZONTAL DISPLACEMENT IN ANY DIRECTION.
34.ANY WALL MOUNTED FIXTURES SHALL BE MOUNTED SO AS NOT TO PROTRUDE BEYOND 4" FROM THE FACE
OF THE WALL IF MOUNTED AT HEIGHT OF LESS THAN 6'-8" A.F.F.
35.GENERAL CONTRACTOR SHALL FURNISH MAD WITH PLANS SHOWING LOCATIONS OF ALL LIGHT SENSORS,
EMERGENCY LIGHT STROBES, SMOKE DETECTORS, LIFE SAFETY PUBLIC ANNOUNCEMENT SPEAKERS AND
THERMOSTATS FOR REVIEW PRIOR TO ORDERING AND INSTALLATION.
36.CUT SHEETS AND/OR SHOP DRAWINGS OF ALL REGISTERS AND ACCESS PANELS (AS REQUIRED) SHALL BE
SUBMITTED TO MAD FOR REVIEW PRIOR TO FABRICATION, INSTALLATION, OR RELOCATION.
37.CONTRACTOR SHALL SUBMIT MECHANICAL AND SPRINKLER DRAWINGS TO MAD FOR APPROVAL OF
LOCATION OF SPRINKLER HEADS AND HVAC GRILLES.
38.THE GENERAL CONTRACTOR SHALL SUBMIT ONE (1) ELECTRONIC (PDF PREFERRED) SUBMITTAL OF SPECIFIED
LIGHT FIXTURES AND EQUIPMENT. IN ADDITION, TWO (2) FULL WORKING SAMPLES OF SPECIFIED LIGHT
FIXTURES SHALL BE SUBMITTED, IF REQUESTED BY MAD.
GENERAL FLOOR FINISH NOTES
1.ALL INTERIOR FINISHES SHALL CONFORM WITH CURRENT CBC CHAPTER 8 AND ARE TO COMPLY WITH CLASS
III FLAME-SPREAD REQUIREMENTS.
2.FLOORING SHALL MEET ALL CURRENT NON-SLIP STANDARDS AND REQUIREMENTS SPECIFIED BY APPLICABLE
CODES AND/OR AUTHORITIES. CONTRACTOR SHALL PROVIDE NON-SLIP COATINGS AS NECESSARY TO MEET
THESE REQUIREMENTS.
3.ALL MATERIALS AND INSTALLATIONS OF THE SAME SHALL COMPLY WITH ALL APPLICABLE LOCAL BUILDING,
FIRE AND ADA MUNICIPAL CODES.
4.ALL NEW FINISH FLOOR SHALL BE INSTALLED BY CONTRACTOR AS SPECIFIED ON FINISH PLANS.
5.ALL WORKMANSHIP SHALL BE OF THE BEST QUALITY. WHEN THE WORK IS COMPLETE, IT SHALL BE FREE FROM
BUCKLES, BUBBLES, OPEN JOINTS, OR OTHER IMPERFECTIONS. SEAMS SHALL BE KEPT IN ACCURATE
ALIGNMENT ALONG BOTH COORDINATES. TILES HAVING CHIPPED OR ROUNDED CORNERS WILL BE
REJECTED AND IF INSTALLED, SHALL BE REMOVED AND REPLACED WITH ACCEPTABLE TILES AT CONTRACTOR'S
EXPENSE.
6.THE GENERAL CONTRACTOR SHALL FLASH ALL CRACKS, HOLES, OR OTHER IMPERFECTIONS (PROJECTIONS
SHALL BE REMOVED AND PATCHED) TO PROVIDE A CONTINUOUSLY SMOOTH FLOOR SURFACE WITH
VARIATION IN LEVEL NOT TO EXCEED 1/4" IN 10'-0" NON-CUMULATIVE.
7.THE GENERAL CONTRACTOR SHALL NOTIFY MAD AFTER FLOOR PATCHING IS COMPLETE FOR FIELD
INSPECTION PRIOR TO THE INSTALLATION OF FINISH FLOOR.
8.GENERAL CONTRACTOR SHALL COORDINATE WORK OF ALL FLOORING CONTRACTORS TO ENSURE THAT
ALL VARYING FLOOR MATERIALS USED ARE INSTALLED FLUSH. ALL TRANSITION METHODS SHALL BE APPROVED
BY MAD PRIOR TO INSTALLATION.
9.GENERAL CONTRACTOR SHALL FOLLOW ALL MANUFACTURERS RECOMMENDATIONS AND INSTRUCTIONS
FOR THE INSTALLATION OF ANY FINISHES OR PRODUCTS.
10.TILES SHALL BE LAID IN SQUARE PATTERN WITH COURSES PARALLEL TO WALLS, U.O.N. ON THE DRAWINGS.
TILES SHALL BE SECURELY CEMENTED AND SHALL BE LAID WITH TIGHT JOINTS. THE ADHESIVE USED FOR
CEMENTING THE TILES SHALL BE APPLIED FAR ENOUGH IN ADVANCE OF SETTING TO PERMIT THE ADHESIVE
TO REACH ITS INITIAL SET, BUT NOT ITS FINAL SET. ADHESIVES USED ARE TO BE NON-COMBUSTIBLE.
11.AREAS WHERE FLOOR FINISH IS SCHEDULED SHALL BE CLOSED TO TRAFFIC AND OTHER WORK DURING
INSTALLATION OF FINISH FLOOR.
12.UPON COMPLETION, ALL FLOOR FINISH WORK SHALL BE CLEANED BY THE CONTRACTOR, REMOVING ALL
SPOTS OF ADHESIVE, SURFACE STAINS, AND ALL SCRAPS. CARTONS AND CONTAINERS SHALL BE REMOVED
FROM THE BUILDING.
13.AFTER CLEANING, THE CONTRACTOR SHALL PROVIDE (2) APPLICATIONS OF AN APPROVED NON-SLIP WAX TO
RESILIENT TILE FLOOR, WHICH SHALL BE THOROUGHLY MACHINE-BUFFED AND LEFT IN CONDITION ENTIRELY
ACCEPTABLE TO MAD.
14.THE CONTRACTOR SHALL PROVIDE AND MAINTAIN ADEQUATE PROTECTION FOR ALL FLOORING WORK FOR
THE DURATION OF THE CONTRACT. ALL PROTECTION SHALL BE REMOVED PRIOR TO PUNCH LIST.
15.ACCURATE, DIMENSIONED FLOORING PLANS SHALL BE SUBMITTED TO MAD FOR APPROVAL PRIOR TO
INSTALLATION. ELECTRONIC FILE (PDF PREFERRED) SUBMITTAL IS ACCEPTABLE.
16.GENERAL CONTRACTOR SHALL FOLLOW ALL MANUFACTURERS RECOMMENDATIONS AND INSTRUCTIONS
FOR THE INSTALLATION OF ALL FINISHES OR PRODUCTS.
17.GENERAL CONTRACTOR SHALL SUBMIT AN ELECTRONIC FILE (PDF PREFERRED) OF CARPET SEAMING DIAGRAM
INCLUDING DIRECTION OF CARPET TO MAD FOR APPROVAL PRIOR TO ORDERING AND PRIOR TO
INSTALLATION OF MATERIALS.
18.PLASTIC LAMINATE BASE SHALL BE PROVIDED ON ALL MILLWORK SCHEDULED TO RECEIVE PLASTIC LAMINATE
FINISH (SEE ELEVATIONS).
19.GENERAL CONTRACTOR SHALL SUBMIT (3) 8" X 8" SAMPLES OF ALL FINISHES TO MAD FOR APPROVAL, PRIOR
TO PURCHASE OR INSTALLATION.
20.NO SUBSTITUTIONS OF FINISHES SHALL BE MADE WITHOUT PRIOR WRITTEN APPROVAL FROM MAD.
GENERAL MILLWORK NOTES
1.REFER TO SHEET ID3.0 FOR EQUIPMENT, FIXTURE, AND MILLWORK HARDWARE/ACCESORY SCHEDULES FOR
CONTRACTOR SUPPLIED EQUIPMENT, FIXTURE, AND HARDWARE/ACCESSORIES.
2.ALL PLASTIC LAMINATE MILLWORK TO BE FABRICATED, ASSEMBLED, FINISHED AND ERECTED TO AWI CUSTOM
GRADE STANDARDS. ALL EXPOSED AND SEMI-EXPOSED SURFACES TO BE FINISHED WITH SCHEDULED PLASTIC
LAMINATE. MILLWORK TO BE 5/8" MELAMINE. MILLWORK FINISH, U.O.N.: BLACK AT COLOR PLASTIC
LAMINATE MILLWORK. WHITE AT WHITE OR LIGHT COLORED PLASTIC LAMINATE MILLWORK.
3.ALL VENEERED OR LACQUERED MILLWORK SHALL BE FABRICATED, ASSEMBLED, FINISHED AND ERECTED TO
AWI PREMIUM GRADE STANDARDS. ALL EXPOSED SURFACES INCLUDING DOORS, DRAWERS, FRONTS,
COUNTERTOPS AND BASE SHALL BE VENEERED. UNLESS OTHERWISE NOTED, MILLWORK SHALL BE FULLY
VENEERED.
4.THE GENERAL CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE.
ALL INSTALLED MILLWORK SHALL COMPLY WITH ALL APPLICABLE BUILDING CODES.
5.GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR TAKING FIELD DIMENSIONS IN ALL AREAS SCHEDULED
TO RECEIVE CABINETS NOTED HEREIN.
6.ALL INSTALLED MILLWORK SHALL BE SCRIBED TO WALL OR CEILING. CONTRACTOR SHALL COORDINATE
MILLWORK INSTALLATION WITH THE WORK OF ALL TRADES WHICH HAVE AN IMPACT ON MILLWORK.
7.PROVIDE BRACING IN WALLS AS REQUIRED FOR OVERHEAD CABINETS. WHERE OPEN SHELVING IS INDICATED
PROVIDE ALL EXPOSED EDGE SURFACES WITH PLASTIC LAMINATE FINISHES AND INTERIOR SURFACE WITH
WHITE KORTRON OR MELAMINE.
8.GENERAL CONTRACTOR SHALL ENSURE THAT MILLWORK CONTRACTOR SHALL BE RESPONSIBLE FOR ALL JOB
SITE CONDITIONS. ANY DISCREPANCIES SHALL BE REPORTED TO MAD PRIOR TO FABRICATION OF CABINET
WORK.
9.ALL MILLWORK IS TO BE FABRICATED IN A CONTROLLED SHOP ENVIRONMENT. FIELD WORK SHALL BE LIMITED
TO BLOCKING, TRIMMING, AND ASSEMBLED FINISHED COMPONENTS.
10.ALL MILLWORK JOINERY SHALL BE FABRICATED AND SECURED IN A MANNER WHICH ENSURES THAT THE JOINT
WILL NOT SEPARATE.
11.ALL CUTOUTS IN PLASTIC LAMINATE COUNTER TOPS (SINKS, GROMMET CHASES, ETC.) SHALL BE MADE BY
CABINET SUBCONTRACTOR AT SITE.
12.ALL WOOD VENEER PIECES SHALL BE FINISHED IN THE SHOP WITH SPRAY EQUIPMENT. NO FINISHING OTHER
THAN TOUCHUP TO BE DONE AT JOB SITE.
13.ALL REVEALS SHALL BE 1/8" U.O.N. AND BE ADJACENT WOOD FINISH OR ADJACENT PLASTIC LAMINATE WHERE
SPECIFIED. REFER TO ELEVATIONS.
14.GENERAL CONTRACTOR SHALL COORDINATE APPROPRIATE MUD RINGS FOR OUTLETS LOCATED ON FULL
HEIGHT BACKSPLASH.
15.GENERAL CONTRACTOR SHALL SUPPLY AND INSTALL ALL NECESSARY HARDWARE AS REQUIRED BY THE
SPECIFICATIONS OR INTENT OF THE DESIGNER. SUBMITTALS OF MILLWORK HARDWARE SHALL BE SUBMITTED
TO MAD FOR APPROVAL BEFORE ASSEMBLY.
16.CABINET HARDWARE - SEE MILLWORK HARDWARE/ACCESSORY SCHEDULE SHEET ID3.0 (U.O.N.):
a.ALL HINGES AT ALL MILLWORK SHALL BE FULLY CONCEALED.
b.ALL DRAWER GLIDES SHALL BE FULL EXTENSION EXTRA HEAVY DUTY; GLIDES TO BE BLACK AT BLACK
CASEWORK; SILVER OR WHITE AT WHITE CASEWORK.
c.ALL GROMMETS SHALL BE DOUG MOCKETT "THE MAX" SATIN ALUMINUM FINISH OR APPROVED EQUAL. ALL
GROMMET LOCATIONS TO BE FIELD VERIFIED BY ARCHITECT PRIOR TO INSTALLATION.
d.PEDESTAL CABINETS TO ACCOMMODATE PENDEFLAX LETTER AND/OR LEGAL FOLDERS. PROVIDE METAL
BRACES.
e.WASTE RECEPTACLE DRAWERS SHALL HAVE TWO (2) SETS OF HEAVY DUTY GLIDES.
17.ALL MILLWORK FINISHES SHALL BE AS SPECIFIED ON PLANS, SCHEDULES, ELEVATIONS AND/OR DETAILS,
U.O.N.
18.GENERAL CONTRACTOR TO SUBMIT AN ELECTRONIC FILE (PDF PREFERRED) MILLWORK SHOP DRAWINGS FOR
APPROVAL BEFORE FABRICATION AND INSTALLATION. CONFIRM FINISHES ON SHOP DRAWINGS FOR MAD'S
APPROVAL BEFORE FABRICATION. SUBMIT (4) 12"x12" SAMPLES OF EACH FINISH FOR APPROVAL.
19.ALL SPECIAL MILLWORK PRODUCTS AND SPECIAL ASSEMBLIES ARE SUBJECT TO SUBMITTAL AND REVIEW. SHOP
DRAWINGS AND SUBMITTALS SHALL NOT BE WAIVED UNLESS WRITTEN PERMISSION TO DO SO IS GIVEN BY
MAD.
20.MILLWORK SHOP DRAWINGS SHALL CALL OUT ALL MATERIALS AND FINISHES. ALL JOINTS, CORNERS, AND
EDGES SHALL BE DESCRIBED IN DETAIL DRAWINGS. ALL DIMENSIONS, CRITICAL OR OTHERWISE, SHALL BE
CALLED OUT ON THE SHOP DRAWINGS. MAD WILL NOT REVIEW SHOP DRAWINGS WHICH ARE INCOMPLETE
AND/OR WHICH SHOW MINIMAL DETAIL.
GENERAL WALL FINISH NOTES
1.ALL INTERIOR FINISHES SHALL CONFORM WITH CURRENT CBC CHAPTER 8.
2.ALL AREAS ARE TO BE PAINTED IN ACCORDANCE WITH FINISH PLANS UNLESS OTHERWISE NOTED OR
SPECIFIED.
3.PAINT COLORS AND ALL OTHER WALL FINISHES INCLUDING WALL COVERING SHALL BE AS SPECIFIED BY MAD.
4.THE GENERAL CONTRACTOR SHALL USE SPECIFIED PAINT PRODUCTS. IF SUBSTITUTION OF MANUFACTURER
IS REQUESTED, THE CONTRACTOR SHALL PROVIDE MANUFACTURER'S LITERATURE, INCLUDING FULL
APPLICATION SPECIFICATIONS, TO MAD FOR APPROVAL IN ADVANCE OF APPLICATION.
5.WALLS SHALL BE DEFINED AS SURFACES FROM FLOOR TO CEILING, INCLUDING PILASTERS, FASCIAS, JAMBS,
BUCKS, REVEALS, RETURNS, AND ALL VERTICAL SURFACES NOT INCLUDED IN CEILING.
6.INDICATIONS OF EXTENT OF WALL FINISH ARE GRAPHICALLY SYMBOLIC AND DO NOT REPRESENT EVERY
JOG, PROTRUSION, OR RECESS OCCURRING ON THE ACTUAL CONSTRUCTED SURFACE (NEW OR EXISTING).
THE CONTRACTOR SHALL PROVIDE SPECIFIED FINISH ON ALL SURFACES WITHIN THE LIMITS SHOWN ON THE
PLANS.
7.THE CONTRACTOR SHALL INSPECT ALL SURFACES FOR HOLES, CRACKS, AND ANY OTHER CONDITIONS
WHICH WOULD ADVERSELY IMPACT PAINT APPLICATION. ALL EXISTING LOOSE PAINT SHALL BE REMOVED.
ALL SURFACES SHALL BE PROPERLY PREPARED, PATCHED AS APPROPRIATE TO A SMOOTH CONDITION, AND
MADE READY FOR PRIME AND PAINT. THE CONTRACTOR SHALL NOT PROCEED WITH THE PAINTING WORK
UNTIL THIS HAS OCCURRED AT ALL SURFACES SCHEDULED TO RECEIVE PAINT.
8.COMMENCEMENT OF PAINTING WORK SHALL REPRESENT ACCEPTANCE OF SURFACE CONDITIONS.
9.THE GENERAL CONTRACTOR SHALL CAREFULLY REMOVE AND STORE ALL ELECTRICAL SWITCH AND OUTLET
PLATES, SURFACE HARDWARE, ETC. PRIOR TO PAINTING AND REPLACE THEM WHEN PAINTING WORK IS
COMPLETE. ALL PAINT SPILLED, SPLASHED, OR SPLATTERED ON DIFFUSERS, REGISTERS, SLAB FITTINGS, ETC.
SHALL BE REMOVED WHEN PAINTING WORK IS COMPLETE. THE CONTRACTOR SHALL REPLACE ANY ITEMS
DAMAGED DURING THIS PROCESS WITH NEW ITEM TO MATCH EXISTING.
10.ALL WOOD SHELVING AND PAINTED DOORS SHALL RECEIVE PRIMING, SANDING, AND (2) FULL COATS OF
SEMI-GLOSS ENAMEL FREE OF BRUSH MARKS. THE CONTRACTOR SHALL EXAMINE ALL AREAS OF
CONSTRUCTION AFTER COMPLETION OF ALL WORK AND PERFORM NECESSARY "TOUCH-UP" PAINTING
AND/OR PATCHING.
11.THE GENERAL CONTRACTOR SHALL INSTALL WALL COVERING PER MANUFACTURER'S SPECIFICATIONS WHERE
INDICATED ON FINISH PLANS. WALL COVERING SHALL BE INSTALLED SMOOTH, WITHOUT WRINKLES,
BUBBLES OR LOOSE EDGES. ALL PASTE AND BRUSH MARKS SHALL BE REMOVED. WALL COVERING
ADJOINING WOOD AND METAL TRIM SHALL BE CUT STRAIGHT AND SQUARE. WALL COVERING AT ALL
REVEALS SHALL RETURN INTO REVEAL. ALL WORKMANSHIP WHICH IS NOT JUDGED TO BE FIRST QUALITY BY
MAD WILL NOT BE ACCEPTED.
13.REPAIR, PATCH (IF REQUIRED) EXISTING WALLS AND RE PAINT AS SPECIFIED.
14.SOFFIT AND FASCIA FINISH SHALL MATCH ADJACENT WALL COLOR, U.O.N.
15.SEE REFLECTED CEILING PLAN FOR CEILING FINISHES & LOCATION.
16.ALL ACCESS DOORS AND PANELS LOCATED IN DRYWALL CEILINGS AND WALL SHALL BE PAINTED TO MATCH
ADJACENT SURFACE COLOR AND FINISH, U.O.N.
17.GENERAL CONTRACTOR SHALL COORDINATE ALL FINISHES ON MILLWORK AS SHOWN ON MILLWORK PLANS
WITH THE MILLWORK SUB-CONTRACTOR.
GREEN BUILDING NOTES
1.INTERIOR AND EXTERIOR LIGHTING SHALL BE INSTALLED SUCH THAT ZERO DIRECT-BEAM ILLUMINATION
LEAVES THE BUILDING SITE.
2.ALL NEW EXTERIOR LUMINAIRES SHALL BE SHIELDED OR BE CUTOFF LUMINAIRES AS DEFINED IN SECTION 132
(b) OF THE CALIFORNIA ENERGY CODE.
3.NEW NON-RESIDENTIAL GRADE EQUIPMENT AND APPLIANCES PROVIDED AND INSTALLED SHALL BE ENERGY
STAR LABELED IF ENERGY STAR IS APPLICABLE TO THAT EQUIPMENT OR APPLIANCE.
4.NONABSORBENT FLOOR AND WALL FINISH SHALL BE USED WITHIN AT LEAST TWO FEET AND PERPENDICULAR
TO EXTERIOR ENTRIES AND/OR OPENING SUBJECT TO FOOT TRAFFIC.
5.WHEN PROJECT OCCURS WITHIN THE LOS ANGELES CITY LIMITS, ONLY A CITY OF LOS ANGELES CERTIFIED
HAULER WILL BE USED FOR HAULING OF CONSTRUCTION WASTE.
6."AN OPERATION AND SYSTEMS MANUAL" SHALL BE PROVIDED TO THE FIELD INSPECTOR AT THE TIME OF
FINAL INSPECTION.
7.ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE,
PLASTIC, OR SHEETMETAL UNTIL THE FINAL STARTUP OF THE HEATING AND COOLING EQUIPMENT.
8.THE VOC CONTENT VERIFICATION CHECKLIST, FORM GRN 2, SHALL BE COMPLETED AND VERIFIED PRIOR TO
FINAL INSPECTION APPROVAL. THE MANUFACTURER'S SPECIFICATIONS SHOWING VOC CONTENT FOR ALL
APPLICABLE PRODUCTS SHALL BE READILY AVAILABLE AT THE JOB SITE AND BE PROVIDED TO THE FIELD
INSPECTOR FOR VERIFICATION.
9.ALL NEW CARPET INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE TESTING AND PRODUCT
REQUIREMENTS OF ONE OF THE FOLLOWING:
a.CARPET AND RUG INSTITUTE'S GREEN LABEL PLUS PROGRAM;
b.CALIFORNIA DEPARTMENT OF PUBLIC HEALTH STANDARD PRACTICE FOR TESTING OF (VOLATILE
ORGANIC COMPOUNDS) VOCs (SPECIFICATION 01350);
c.NSF/ANSI 140 AT THE GOLD LEVEL; OR
d.SCIENTIFIC CERTIFICATIONS SYSTEMS INDOOR ADVANTAGE GOLD
10.ALL NEW CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR SHALL MEET REQUIREMENTS OF THE
CARPET AND RUG INSTITUTE GREEN LABEL PROGRAM.
11.THE FORMALDEHYDE EMISSIONS VERIFICATION CHECKLIST, FORM GRN 3, SHALL BE COMPLETED PRIOR TO
FINAL INSPECTION APPROVAL. THE MANUFACTURER'S SPECIFICATIONS SHOWING FORMALDEHYDE CONTENT
FOR ALL APPLICABLE WOOD PRODUCTS SHALL BE READILY AVAILABLE AT THE JOB SITE AND BE PROVIDED TO
THE FIELD INSPECTOR FOR VERIFICATION.
12.50% OF THE TOTAL AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH THE VOC LIMITS OR BE
CERTIFIED UNDER THE RESILIENT FLOOR COVERING INSTITUTE (RFCI) FLOORSCORE PROGRAM.
13.AN AIR FILTER WITH A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 8 OR HIGHER SHALL BE INSTALLED
IN NEW MECHANICAL SYSTEMS FOR OUTSIDE AND RETURN AIR PRIOR TO OCCUPANCY.
14.THE HVAC, REFRIGERATION, FIRE SUPPRESSION EQUIPMENT SHALL NOT CONTAIN CFC OR HALONS.
15.ARCHITECTURAL PAINTS AND COATINGS, ADHESIVES, CAULKS AND SEALANTS SHALL COMPLY WITH THE
VOLATILE ORGANIC COMPOUND (VOC) LIMITS LISTED IN TABLES 10.504.4.1 - 10.504.4.3.
16.AEROSOL PAINTS AND COATINGS SHALL MEET THE PRODUCT-WEIGHTED MIR LIMITS FOR ROC IN SECTION
94522(A)(3) AND OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC
COMPOUNDS AND OZONE DEPLETING SUBSTANCES, IN SECTIONS 94522(C)(2) AND (D)(2) OF CALIFORNIA
CODE OF REGULATIONS, TITLE 17, COMMENCING WITH SECTION 94520; AND IN AREAS UNDER THE
JURISDICTION OF THE SOUTH COAST AREA AIR QUALITY MANAGEMENT DISTRICT ADDITIONALLY COMPLY
WITH THE PERCENT VOC BY WEIGHT OF PRODUCT LIMITS OF REGULATION 8, RULE 49
17.ALL SEALERS, STAINS, AND FINISHES ON CONCRETE, WOOD, BAMBOO, OR CORK MUST COMPLY WITH THE
SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQD) RULE 113, ARCHITECTURAL COATINGS.
GENERAL CONTRACTOR SHALL SUBMIT ALL SEALERS, STAINS, AND FINISHES BEING USED ON THE PROJECT TO
WDG FOR APPROVAL PRIOR TO INSTALLATION.
18.NEW PLUMBING FIXTURES AND FITTINGS SHALL NOT EXCEED THE MAXIMUM ALLOWABLE FLOW RATE
SPECIFIED IN TABLE 10.303.2.3.
19.A FINAL REPORT FOR THE TESTING AND ADJUSTING OF ALL NEW SYSTEMS SHALL BE COMPLETED AND
PROVIDED TO THE FIELD INSPECTOR PRIOR TO FINAL INSPECTION. THIS REPORT SHALL BE SIGNED BY THE
INDIVIDUAL RESPONSIBLE FOR PERFORMING THESE SERVICES.
20.NEW HARDWOOD PLYWOOD, PARTICLE BOARD, AND MEDIUM DENSITY FIBERBOARD COMPOSITE WOOD
PRODUCTS USED IN THE INTERIOR OR EXTERIOR OF THE BUILDING SHALL MEET THE FORMALDEHYDE LIMITS
LISTED IN TABLE 10.504.4.5.
21.THE BUILDING SHALL MEET OR EXCEED THE PROVISIONS FOR MECHANICAL VENTILATION OF SECTION 1203
OR THE LOS ANGELES BUILDING CODE.
22.BUILDINGS THAT USE DEMAND CONTROL VENTILATION SHALL HAVE CO₂ SENSORS AND VENTILATION
CONTROLS INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE CURRENT EDITION OF THE
CALIFORNIA ENERGY CODE, CCR, TITLE 24, PART 6, SECTION 121(c).
23.IF THE NEW HVAC SYSTEM IS USED DURING CONSTRUCTION, USE RETURN AIR FILTERS WITH A
MERV OF 8. REPLACE ALL FILTERS IMMEDIATELY PRIOR TO OCCUPPANCY.
24.TESTING AND ADJUSTMENT IS REQUIRED FOR ALL NEW INSTALLATION OF ANY OF THE FOLLOWING SYSTEMS:
a. HEATING VENTILATING AND AIR CONDITIONING SYSTEM
i. DESCRIBE THE HVAC SYSTEMS AND CONTROLS.
ii. PLANS SHALL INDICATE THAT THE HVAC SYSTEM AND COMPONENTS WILL BE TESTED, ADJUSTED
AND BALANCED IN ACCORDANCE WITH ONE OF THE FOLLOWING:
·TABB'S CONSTRUCTION SPECIFICATION INSTITUTE MASTERFORMAT
·NEBB'S STANDARDS FOR TESTING, ADJUSTMENT AND BALANCING OF ENVIRONMENTAL SYSTEMS
(7TH EDITION)
·AABC'S NATIONAL STANDARDS FOR TOTAL SYSTEM BALANCE (6TH EDITION)
·ASHRAE'S STANDARD 111-2008
b. INDOOR AND OUTDOOR LIGHTING AND CONTROLS:
i. DESCRIBE THE TYPES OF LIGHTING FIXTURES USED AND THEIR CORRESPONDING CONTROLS AT
VARIOUS SPACES/ROOMS WITHING THE BUILDING (E.G. DIMMERS, OCCUPANCY SENSORS,
PROGRAMMABLE TIME SWITCHES, PHOTOSENSORS, ETC.)
ii. PROVIDE A NARRATIVE OF THE TESTING AND ADJUSTMENT PROCEDURE FOR THE LIGHTING
CONTROLS.
Sheet Title:
ISSUE DATE
ISSUE FOR PLANCHECK 12.22.2025
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ENGINEER/CONSULTANT
ARCHITECT/ENGINEER STAMP
30
5
W
4
T
H
S
T
R
E
E
T
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
1
CA
F
E
OA
S
I
S
CLIENT
www.madstudiola.com
CITY STAMP
Project Director:
Project Designer:
Project Tech:
Project No:25030.300E.M.
E.M.
S.P.
ISSUED FOR MEP 01.13.2026
ISSUED FOR PLAN CHECK COMMENTS- PLANNING DEPT.01.22.2026
ISSUED FOR PRICING 02.17.2026
ISSUED FOR PLAN CHECK COMMENTS - PLANNING DEPT.02.20.2026
ISSUED FOR COUNTY REVIEW 03.24.2026
ISSUED FOR ADDENDUM A 03.27.2026
ISSUED FOR BUILDING DEPT REVIEW 04.08.2026
ISSUED FOR BUILDING DEPT REVIEW - RESUBMITTAL 05.05.2026
ISSUED FOR BUILDING DEPT CORRECTIONS 05.20.2026
ID0.2
GENERAL NOTES
FLOOR AND GROUND SURFACES
1.FLOOR AND GROUND SURFACES SHALL BE STABLE, FIRM, AND SLIP RESISTANT.
2.CARPET OR CARPET TILE SHALL BE SECURELY ATTACHED AND SHALL HAVE A FIRM CUSHION, PAD, OR
BACKING OR NO CUSHION OR PAD. CARPET OR CARPET TILE SHALL HAVE A LEVEL LOOP, TEXTURED LOOP,
LEVEL CUT PILE, OR LEVEL CUT/UNCUT PILE TEXTURE. PILE HEIGHT SHALL BE ½ INCH MAXIMUM.
CHANGES IN LEVEL
3.VERTICAL CHANGES IN LEVEL FOR FLOOR OR GROUND SURFACES MAY BE ¼ INCH HIGH MAXIMUM AND
WITHOUT EDGE TREATMENT. CHANGES IN LEVEL GREATER THAN ¼ INCH AND NOT EXCEEDING ½ INCH IN
HEIGHT SHALL BE BEVELED WITH A SLOPE NOT STEEPER THAN 1:2.
4.CHANGES IN LEVEL GREATER THAN ½ INCH IN HEIGHT SHALL BE RAMPED AND SHALL COMPLY WITH THE
REQUIREMENTS OF 11B-405 RAMPS OR 11B-406 CURB RAMPS AS APPLICABLE.
5.ABRUPT CHANGES IN LEVEL EXCEEDING 4 INCHES IN A VERTICAL DIMENSION BETWEEN WALKS, SIDEWALKS
OR OTHER PEDESTRIAN WAYS AND ADJACENT SURFACES OR FEATURES SHALL BE IDENTIFIED BY WARNING
CURBS AT LEAST 6 INCHES IN HEIGHT ABOVE THE WALK OR SIDEWALK SURFACE OR BY GUARDS OR
HANDRAILS WITH A GUIDE RAIL CENTERED 2 INCHES MINIMUM AND 4 INCHES MAXIMUM ABOVE THE
SURFACE OF THE WALK OR SIDEWALK. THESE REQUIREMENTS DO NOT APPLY BETWEEN A WALK OR
SIDEWALK AND AN ADJACENT STREET OR DRIVEWAY.
TURNING SPACE
6.CIRCULAR TURNING SPACES SHALL BE A SPACE OF 60 INCHES DIAMETER MINIMUM AND MAY INCLUDE KNEE
AND TOE CLEARANCE COMPLYING WITH 11B-306 KNEE AND TOE CLEARANCE.
7.T-SHAPED TURNING SPACES SHALL BE A T-SHAPED SPACE WITHIN A 60 INCH SQUARE MINIMUM WITH ARMS
AND BASE 36 INCHES WIDE MINIMUM. EACH ARM OF THE T SHALL BE CLEAR OF OBSTRUCTIONS 12 INCHES
MINIMUM IN EACH DIRECTION AND THE BASE SHALL BE CLEAR OF OBSTRUCTIONS 24 INCHES MINIMUM.
KNEE AND TOE CLEARANCE
8.FOR LAVATORIES AND BUILT-IN DINING AND WORK SURFACES REQUIRED TO BE ACCESSIBLE, TOE
CLEARANCE SHALL BE PROVIDED THAT IS 30 INCHES IN WIDTH AND 9 INCHES IN HEIGHT ABOVE THE FINISH
FLOOR OR GROUND FOR A DEPTH OF 19 INCHES MINIMUM.
9.TOE CLEARANCE SHALL EXTEND 19 INCHES MAXIMUM UNDER LAVATORIES FOR TOILET AND BATHING
FACILITIES AND 25 INCHES MAXIMUM UNDER OTHER ELEMENTS.
10.AT LAVATORIES IN TOILET AND BATHING FACILITIES, KNEE CLEARANCE SHALL BE PROVIDED THAT IS 30
INCHES IN WIDTH FOR A DEPTH OF 11 INCHES AT 9 INCHES ABOVE THE FINISH FLOOR OR GROUND AND
FOR A DEPTH OF 8 INCHES AT 27 INCHES ABOVE THE FINISH FLOOR OR GROUND INCREASING TO 29
INCHES HIGH MINIMUM ABOVE THE FINISH FLOOR OR GROUND AT THE FRONT EDGE OF A COUNTER
WITH A BUILT-IN LAVATORY OR AT THE FRONT EDGE OF A WALL-MOUNTED LAVATORY FIXTURE.
11.AT DINING AND WORK SURFACES REQUIRED TO BE ACCESSIBLE, KNEE CLEARANCE SHALL BE PROVIDED
THAT IS 30 INCHES IN WIDTH AT 27 INCHES ABOVE THE FINISH FLOOR OR GROUND FOR A DEPTH OF AT
LEAST 19 INCHES.
PROTRUDING OBJECTS
12.EXCEPT FOR HANDRAILS, OBJECTS WITH LEADING EDGES MORE THAN 27 INCHES AND LESS THAN 80
INCHES ABOVE THE FINISH FLOOR OR GROUND SHALL PROTRUDE NO MORE THAN 4 INCHES
HORIZONTALLY INTO THE CIRCULATION PATH. HANDRAILS MAY PROTRUDE 4½ INCHES MAXIMUM.
13.FREESTANDING OBJECTS MOUNTED ON POSTS OR PYLONS SHALL OVERHANG CIRCULATION PATHS NO
MORE THAN 12 INCHES WHEN LOCATED FROM 27 TO 80 INCHES ABOVE THE FINISH FLOOR OR GROUND.
14.PROTRUDING OBJECTS SHALL NOT REDUCE THE CLEAR WIDTH REQUIRED FOR ACCESSIBLE ROUTES.
15.LOWEST EDGE OF A SIGN OR OTHER OBSTRUCTION, WHEN MOUNTED BETWEEN POSTS OR PYLONS
SEPARATED WITH A CLEAR DISTANCE GREATER THAN 12 INCHES, SHALL BE LESS THAN 27 INCHES OR MORE
THAN 80 INCHES ABOVE THE FINISH FLOOR OR GROUND.
16.VERTICAL CLEARANCE SHALL BE AT LEAST 80 INCHES HIGH ON CIRCULATION PATHS EXCEPT AT DOOR
CLOSERS AND DOOR STOPS, WHICH MAY BE 78 INCHES MINIMUM ABOVE THE FINISH FLOOR OR
GROUND.
17.GUARDRAILS OR OTHER BARRIERS WITH A LEADING EDGE LOCATED 27 INCHES MAXIMUM ABOVE THE
FINISH FLOOR OR GROUND SHALL BE PROVIDED WHERE THE VERTICAL CLEARANCE ON CIRCULATION
PATHS IS LESS THAN 80 INCHES HIGH.
18.WHERE A GUY SUPPORT IS USED WITHIN EITHER THE WIDTH OF A CIRCULATION PATH OR 24 INCHES
MAXIMUM OUTSIDE OF A CIRCULATION PATH, A VERTICAL GUY BRACE, SIDEWALK GUY OR SIMILAR DEVICE
SHALL BE USED TO PREVENT A HAZARD OR AN OVERHEAD OBSTRUCTION.
REACH RANGES
19.ELECTRICAL CONTROLS AND SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF A ROOM OR AREA
TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES OR COOLING, HEATING AND
VENTILATING EQUIPMENT SHALL BE LOCATED WITHIN ALLOWABLE REACH RANGES. LOW REACH SHALL BE
MEASURED TO THE BOTTOM OF THE OUTLET BOX AND HIGH REACH SHALL BE MEASURED TO THE TOP OF
THE OUTLET BOX.
20.ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES OR LESS AND COMMUNICATION
SYSTEM RECEPTACLES SHALL BE LOCATED WITHIN ALLOWABLE REACH RANGES. LOW REACH SHALL BE
MEASURED TO THE BOTTOM OF THE OUTLET BOX AND HIGH REACH SHALL BE MEASURED TO THE TOP OF
THE OUTLET BOX.
21.HIGH FORWARD REACH THAT IS UNOBSTRUCTED SHALL BE 48 INCHES MAXIMUM AND THE LOW FORWARD
REACH SHALL BE 15 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND.
22.HIGH FORWARD REACH SHALL BE 48 INCHES MAXIMUM WHERE THE REACH DEPTH IS 20 INCHES OR LESS
AND 44 INCHES MAXIMUM WHERE THE REACH DEPTH EXCEEDS 20 INCHES. HIGH FORWARD REACH SHALL
NOT EXCEED 25 INCHES IN DEPTH.
23.HIGH SIDE REACH SHALL BE 48 INCHES MAXIMUM AND THE LOW SIDE REACH SHALL BE 15 INCHES
MINIMUM ABOVE THE FINISH FLOOR WHERE THE SIDE REACH IS UNOBSTRUCTED OR THE DEPTH OF ANY
OBSTRUCTION DOES NOT EXCEED 10 INCHES.
24.HIGH SIDE REACH SHALL BE 46 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND WHERE THE
HIGH SIDE REACH IS OVER AN OBSTRUCTION MORE THAN 10 INCHES BUT NOT MORE THAN 24 INCHES IN
DEPTH.
25.OBSTRUCTIONS FOR HIGH SIDE REACH SHALL NOT EXCEED 34 INCHES IN HEIGHT AND 24 INCHES IN
DEPTH.
26.OBSTRUCTED HIGH SIDE REACH FOR THE TOP OF WASHING MACHINES AND CLOTHES DRYERS SHALL BE
PERMITTED TO BE 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR.
27.OBSTRUCTED HIGH SIDE REACH FOR THE OPERABLE PARTS OF FUEL DISPENSERS SHALL BE PERMITTED TO BE
54 INCHES MAXIMUM MEASURED FROM THE SURFACE OF THE VEHICULAR WAY WHERE FUEL DISPENSERS
ARE INSTALLED ON EXISTING CURBS.
OPERABLE PARTS
28.OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING,
PINCHING, OR TWISTING OF THE WRIST. FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5
POUNDS MAXIMUM.
DETECTABLE WARNINGS AND DETECTABLE DIRECTIONAL TEXTURE
29.DETECTABLE WARNING SURFACES SHALL BE YELLOW AND APPROXIMATE FS 33538 OF FEDERAL STANDARD
595C.
30.DETECTABLE WARNING SURFACES SHALL PROVIDE A 70 PERCENT MINIMUM VISUAL CONTRAST WITH
ADJACENT WALKING SURFACES. CONTRAST IN PERCENT SHALL BE DETERMINED BY:
CONTRAST PERCENT = [(B1-B2)/B1] X 100 WHERE
B1 = LIGHT REFLECTANCE VALUE (LRV) OF THE LIGHTER AREA AND
B2 = LIGHT REFLECTANCE VALUE (LRV) OF THE DARKER AREA
DOORS, DOORWAYS, AND GATES
31.DOORS, DOORWAYS, AND GATES PROVIDING USER PASSAGE SHALL BE PROVIDED IN ACCORDANCE WITH
11B-206.5 DOORS, DOORWAYS, AND GATES.
32.DOORS, DOORWAYS AND GATES THAT ARE PART OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH 11B-404
DOORS, DOORWAYS, AND GATES.
33.DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32 INCHES MINIMUM. CLEAR OPENINGS OF
DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND THE
STOP, WITH THE DOOR OPEN 90 DEGREES. OPENINGS MORE THAN 24 INCHES DEEP SHALL PROVIDE A
CLEAR OPENING OF 36 INCHES MINIMUM. THERE SHALL BE NO PROJECTIONS INTO THE REQUIRED CLEAR
OPENING WIDTH LOWER THAN 34 INCHES ABOVE THE FINISH FLOOR OR GROUND. PROJECTIONS INTO
THE CLEAR OPENING WIDTH BETWEEN 34 INCHES AND 80 INCHES ABOVE THE FINISH FLOOR OR GROUND
SHALL NOT EXCEED 4 INCHES.
34.SWINGING DOORS AND GATES SHALL HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE
11B-404.2.4.1.
35.DOORWAYS LESS THAN 36 INCHES WIDE WITHOUT DOORS OR GATES, SLIDING DOORS, OR FOLDING
DOORS SHALL HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE 11B-404.2.4.2.
36.MANEUVERING CLEARANCES FOR FORWARD APPROACH SHALL BE PROVIDED WHEN ANY OBSTRUCTION
WITHIN 18 INCHES OF THE LATCH SIDE AN INTERIOR DOORWAY, OR WITHIN 24 INCHES OF THE LATCH
SIDE OF AN EXTERIOR DOORWAY, PROJECTS MORE THAN 8 INCHES BEYOND THE FACE OF THE DOOR,
MEASURED PERPENDICULAR TO THE FACE OF THE DOOR OR GATE.
37.THRESHOLDS, IF PROVIDED AT DOORWAYS, SHALL BE ½ INCH HIGH MAXIMUM. RAISED THRESHOLDS AND
CHANGES IN LEVEL AT DOORWAYS SHALL COMPLY WITH 11B-302 FLOOR OR GROUND SURFACES AND
11B-303 CHANGES IN LEVEL.
38.HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON DOORS AND GATES SHALL COMPLY
WITH 11B-309.4 OPERATION. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34 INCHES MINIMUM AND
44 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. WHERE SLIDING DOORS ARE IN THE FULLY
OPEN POSITION, OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES.
39.THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE OTHER THAN FIRE DOORS SHALL BE AS
FOLLOWS:
a.INTERIOR HINGED DOORS AND GATES: 5 POUNDS MAXIMUM.
b.SLIDING OR FOLDING DOORS: 5 POUNDS MAXIMUM.
c.REQUIRED FIRE DOORS: THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE
ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 POUNDS.
d.EXTERIOR HINGED DOORS: 5 POUNDS MAXIMUM.
40.SWINGING DOOR AND GATE SURFACES WITHIN 10 INCHES OF THE FINISH FLOOR OR GROUND
MEASURED VERTICALLY SHALL HAVE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH
OF THE DOOR OR GATE. PARTS CREATING HORIZONTAL OR VERTICAL JOINTS IN THESE SURFACES SHALL BE
WITHIN 1/16 INCH OF THE SAME PLANE AS THE OTHER AND BE FREE OF SHARP OR ABRASIVE EDGES.
CAVITIES CREATED BY ADDED KICK PLATES SHALL BE CAPPED.
RAMPS
41.RAMP RUNS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:12 (8.33%).
42.CROSS SLOPE OF RAMP RUNS SHALL NOT BE STEEPER THAN 1:48 (2.083%).
43.FLOOR OR GROUND SURFACES OF RAMP RUNS SHALL COMPLY WITH 11B-302 FLOOR OR GROUND
SURFACES. CHANGES IN LEVEL OTHER THAN THE RUNNING SLOPE AND CROSS SLOPE ARE NOT PERMITTED
ON RAMP RUNS.
44.THE CLEAR WIDTH OF A RAMP RUN SHALL BE 48 INCHES MINIMUM.
45.THE RISE FOR ANY RAMP RUN SHALL BE 30 INCHES MAXIMUM.
46.RAMPS SHALL HAVE LANDINGS AT THE TOP AND THE BOTTOM OF EACH RAMP RUN.
47.LANDINGS SHALL COMPLY WITH 11B-302 FLOOR OR GROUND SURFACES. CHANGES IN LEVEL ARE NOT
PERMITTED.
48.THE LANDING CLEAR WIDTH SHALL BE AT LEAST AS WIDE AS THE WIDEST RAMP RUN LEADING TO THE
LANDING.
49.TOP LANDINGS SHALL BE 60 INCHES WIDE MINIMUM.
50.THE LANDING CLEAR LENGTH SHALL BE 60 INCHES LONG MINIMUM.
51.BOTTOM LANDINGS SHALL EXTEND 72 INCHES MINIMUM IN THE DIRECTION OF RAMP RUN.
52.RAMPS THAT CHANGE DIRECTION BETWEEN RUNS AT LANDINGS SHALL HAVE A CLEAR LANDING 60 INCHES
MINIMUM BY 72 INCHES MINIMUM IN THE DIRECTION OF DOWNWARD TRAVEL FROM THE UPPER RAMP
RUN.
53.WHERE DOORWAYS ARE LOCATED ADJACENT TO A RAMP LANDING, MANEUVERING CLEARANCES REQUIRED
BY 11B-404.2.4 AND 11B-404.3.2 SHALL BE PERMITTED TO OVERLAP THE REQUIRED LANDING AREA. DOORS,
WHEN FULLY OPEN, SHALL NOT REDUCE THE REQUIRED RAMP LANDING WIDTH BY MORE THAN 3 INCHES.
DOORS, IN ANY POSITION, SHALL NOT REDUCE THE MINIMUM DIMENSION OF THE RAMP LANDING TO
LESS THAN 42 INCHES.
54.RAMP RUNS SHALL HAVE COMPLIANT HANDRAILS PER 11B-505 HANDRAILS.
55.EDGE PROTECTION COMPLYING WITH 11B-405.9.2 CURB OR BARRIER SHALL BE PROVIDED ON EACH SIDE
OF RAMP RUNS AND AT EACH SIDE OF RAMP LANDINGS. (SEE EXCEPTIONS)
56.A CURB OR BARRIER SHALL BE PROVIDED THAT PREVENTS THE PASSAGE OF A 4 INCH DIAMETER SPHERE,
WHERE ANY PORTION OF THE SPHERE IS WITHIN 4 INCHES OF THE FINISH FLOOR OR GROUND SURFACE.
TO PREVENT WHEEL ENTRAPMENT, THE CURB OR BARRIER SHALL PROVIDE A CONTINUOUS AND
UNINTERRUPTED BARRIER ALONG THE LENGTH OF THE RAMP.
57.LANDINGS SUBJECT TO WET CONDITIONS SHALL BE DESIGNED TO PREVENT THE ACCUMULATION OF
WATER.
HANDRAILS
58.HANDRAILS SHALL BE PROVIDED ON BOTH SIDES OF STAIRS AND RAMPS.
59.HANDRAILS SHALL BE CONTINUOUS WITHIN THE FULL LENGTH OF EACH STAIR FLIGHT OR RAMP RUN.
INSIDE HANDRAILS ON SWITCHBACK OR DOGLEG STAIRS AND RAMPS SHALL BE CONTINUOUS BETWEEN
FLIGHTS OR RUNS.
60.TOP OF GRIPPING SURFACES OF HANDRAILS SHALL BE 34 INCHES MINIMUM AND 38 INCHES MAXIMUM
VERTICALLY ABOVE WALKING SURFACES, STAIR NOSINGS, AND RAMP SURFACES. HANDRAILS SHALL BE AT A
CONSISTENT HEIGHT ABOVE WALKING SURFACES, STAIR NOSINGS, AND RAMP SURFACES.
61.CLEARANCE BETWEEN HANDRAIL GRIPPING SURFACES AND ADJACENT SURFACES SHALL BE 1½ INCHES
MINIMUM. HANDRAILS MAY BE LOCATED IN A RECESS IF THE RECESS IS 3 INCHES MAXIMUM DEEP AND 18
INCHES MINIMUM CLEAR ABOVE THE TOP OF THE HANDRAIL.
62.HANDRAIL GRIPPING SURFACES SHALL BE CONTINUOUS ALONG THEIR LENGTH AND SHALL NOT BE
OBSTRUCTED ALONG THEIR TOPS OR SIDES. THE BOTTOMS OF HANDRAIL GRIPPING SURFACES SHALL NOT
BE OBSTRUCTED FOR MORE THAN 20 PERCENT OF THEIR LENGTHS. WHERE PROVIDED, HORIZONTAL
PROJECTIONS SHALL OCCUR 1½ INCHES MINIMUM BELOW THE BOTTOM OF THE HANDRAIL-GRIPPING
SURFACE.
63.HANDRAIL GRIPPING SURFACES WITH A CIRCULAR CROSS SECTION SHALL HAVE AN OUTSIDE DIAMETER OF
1¼ INCHES MINIMUM AND 2 INCHES MAXIMUM.
64.HANDRAIL GRIPPING SURFACES WITH A NON-CIRCULAR CROSS SECTION SHALL HAVE A PERIMETER
DIMENSION OF 4 INCHES MINIMUM AND 6¼ INCHES MAXIMUM, AND A CROSS-SECTION DIMENSION OF
2¼ INCHES MAXIMUM.
65.HANDRAIL GRIPPING SURFACES SHALL EXTEND BEYOND AND IN THE SAME DIRECTION OF STAIR FLIGHTS
AND RAMP RUNS IN ACCORDANCE WITH SECTION 11B-505.10 HANDRAIL EXTENSIONS.
66.RAMP HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE THE LANDING FOR 12 INCHES MINIMUM BEYOND
THE TOP AND BOTTOM OF RAMP RUNS. EXTENSIONS SHALL RETURN TO A WALL, GUARD, OR THE LANDING
SURFACE, OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT RAMP RUN.
67.AT THE TOP OF A STAIR FLIGHT, HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE THE LANDING FOR 12
INCHES MINIMUM BEGINNING DIRECTLY ABOVE THE FIRST RISER NOSING. EXTENSIONS SHALL RETURN TO A
WALL, GUARD, OR THE LANDING SURFACE, OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN
ADJACENT STAIR FLIGHT.
68.AT THE BOTTOM OF A STAIR FLIGHT, HANDRAILS SHALL EXTEND AT THE SLOPE OF THE STAIR FLIGHT FOR A
HORIZONTAL DISTANCE EQUAL TO ONE TREAD DEPTH BEYOND THE LAST RISER NOSING. THE HORIZONTAL
EXTENSION OF A HANDRAIL SHALL BE 12 INCHES LONG MINIMUM AND A HEIGHT EQUAL TO THAT OF THE
SLOPING PORTION OF THE HANDRAIL AS MEASURED ABOVE THE STAIR NOSINGS. EXTENSION SHALL
RETURN TO A WALL, GUARD, OR THE LANDING SURFACE, OR SHALL BE CONTINUOUS TO THE HANDRAIL OF
AN ADJACENT STAIR FLIGHT.
STAIRWAYS
69.A STAIR IS DEFINED AS A CHANGE IN ELEVATION, CONSISTING OF ONE OR MORE RISERS.
70.ALL STEPS ON A FLIGHT OF STAIRS SHALL HAVE UNIFORM RISER HEIGHTS AND UNIFORM TREAD DEPTHS.
RISERS SHALL BE 4 INCHES HIGH MINIMUM AND 7 INCHES HIGH MAXIMUM. TREADS SHALL BE 11 INCHES
DEEP MINIMUM. CURVED STAIRWAYS WITH WINDER TREADS ARE PERMITTED AT STAIRS WHICH ARE NOT PART
OF A REQUIRED MEANS OF EGRESS. (SEE EXCEPTION)
71.OPEN RISERS ARE NOT PERMITTED. (SEE EXCEPTIONS)
72.INTERIOR STAIRS SHALL HAVE THE UPPER APPROACH AND LOWER TREAD MARKED BY A STRIPE PROVIDING
CLEAR VISUAL CONTRAST. EXTERIOR STAIRS SHALL HAVE THE UPPER APPROACH AND ALL TREADS MARKED BY
A STRIPE PROVIDING CLEAR VISUAL CONTRAST. THE STRIPE SHALL BE A MINIMUM OF 2 INCHES WIDE TO A
MAXIMUM OF 4 INCHES WIDE PLACED PARALLEL TO, AND NOT MORE THAN 1 INCH FROM, THE NOSE OF
THE STEP OR UPPER APPROACH. THE STRIPE SHALL EXTEND THE FULL WIDTH OF THE STEP OR UPPER
APPROACH AND SHALL BE OF MATERIAL THAT IS AT LEAST AS SLIP RESISTANT AS THE OTHER TREADS OF THE
STAIR. A PAINTED STRIPE SHALL BE ACCEPTABLE. GROOVES SHALL NOT BE USED TO SATISFY THIS
REQUIREMENT.
73.THE RADIUS OF CURVATURE AT THE LEADING EDGE OF THE TREAD SHALL BE ½ INCH MAXIMUM. NOSINGS
THAT PROJECT BEYOND RISERS SHALL HAVE THE UNDERSIDE OF THE LEADING EDGE CURVED OR BEVELED.
RISERS SHALL BE PERMITTED TO SLOPE UNDER THE TREAD AT AN ANGLE OF 30 DEGREES MAXIMUM FROM
VERTICAL. THE PERMITTED PROJECTION OF THE NOSING SHALL EXTEND 1¼ INCHES MAXIMUM OVER THE
TREAD BELOW. (SEE EXCEPTION FOR EXISTING BUILDINGS)
74.STAIRS SHALL HAVE HANDRAILS COMPLYING WITH SECTION 11B-505 HANDRAILS.
75.STAIR TREADS AND LANDINGS SUBJECT TO WET CONDITIONS SHALL BE DESIGNED TO PREVENT THE
ACCUMULATION OF WATER.
76.FLOOR IDENTIFICATION SIGNS REQUIRED BY CHAPTER 10, SECTION 1022.9 COMPLYING WITH SECTIONS
11B-703.1 SIGNS GENERAL, 11B-703.2 RAISED CHARACTERS, 11B-703.3 BRAILLE AND 11B-703.5 VISUAL
CHARACTERS SHALL BE LOCATED AT THE LANDING OF EACH FLOOR LEVEL, PLACED ADJACENT TO THE
DOOR ON THE LATCH SIDE, IN ALL ENCLOSED STAIRWAYS IN BUILDINGS TWO OR MORE STORIES IN
HEIGHT TO IDENTIFY THE FLOOR LEVEL. AT THE EXIT DISCHARGE LEVEL, THE SIGN SHALL INCLUDE A RAISED
FIVE POINTED STAR LOCATED TO THE LEFT OF THE IDENTIFYING FLOOR LEVEL. THE OUTSIDE DIAMETER OF
THE STAR SHALL BE THE SAME AS THE HEIGHT OF THE RAISED CHARACTERS.
CURB RAMPS, BLENDED TRANSITIONS AND ISLANDS
77.PERPENDICULAR RAMP RUNS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:12 (8.33%).
78.FOR PERPENDICULAR RAMPS, WHERE PROVIDED, CURB RAMP FLARES SHALL NOT BE STEEPER THAN 1:10.
79.THE RUNNING SLOPE OF THE CURB RAMP SEGMENTS SHALL BE IN-LINE WITH THE DIRECTION OF SIDEWALK
TRAVEL. RAMP RUNS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:12 (8.33%).
80.A TURNING SPACE 48 INCHES MINIMUM BY 48 INCHES MINIMUM SHALL BE PROVIDED AT THE BOTTOM OF
THE CURB RAMP. THE SLOPE OF THE TURNING SPACE IN ALL DIRECTIONS SHALL BE 1:48 MAXIMUM (2.083%).
81.BLENDED TRANSITION RAMPS HALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:20 (5%).
82.CURB RAMPS AND THE FLARED SIDES OF CURB RAMPS SHALL BE LOCATED SO THAT THEY DO NOT PROJECT
INTO VEHICULAR TRAFFIC LANES, PARKING SPACES, OR PARKING ACCESS AISLES. CURB RAMPS AT MARKED
CROSSINGS SHALL BE WHOLLY CONTAINED WITHIN THE MARKINGS, EXCLUDING ANY FLARED SIDES.
83.THE CLEAR WIDTH OF CURB RAMP RUNS (EXCLUDING ANY FLARED SIDES), BLENDED TRANSITIONS, AND
TURNING SPACES SHALL BE 48 INCHES MINIMUM.
84.LANDINGS SHALL BE PROVIDED AT THE TOPS OF CURB RAMPS AND BLENDED TRANSITIONS (PARALLEL CURB
RAMPS SHALL NOT BE REQUIRED TO COMPLY). THE LANDING CLEAR LENGTH SHALL BE 48 INCHES
MINIMUM. THE LANDING CLEAR WIDTH SHALL BE AT LEAST AS WIDE AS THE CURB RAMP, EXCLUDING ANY
FLARED SIDES, OR THE BLENDED TRANSITION LEADING TO THE LANDING. THE SLOPE OF THE LANDING IN
ALL DIRECTIONS SHALL BE 1:48 (2.083%) MAXIMUM.
85.GRADE BREAKS AT THE TOP AND BOTTOM OF CURB RAMP RUNS SHALL BE PERPENDICULAR TO THE
DIRECTION OF THE RAMP RUN. GRADE BREAKS SHALL NOT BE PERMITTED ON THE SURFACE OF RAMP RUNS
AND TURNING SPACES. SURFACE SLOPES THAT MEET AT GRADE BREAKS SHALL BE FLUSH.
86.THE CROSS SLOPE OF CURB RAMPS AND BLENDED TRANSITIONS SHALL BE 1:48 (2.083%) MAXIMUM.
87.COUNTER SLOPES OF ADJOINING GUTTERS AND ROAD SURFACES IMMEDIATELY ADJACENT TO AND
WITHIN 24 INCHES OF THE CURB RAMP SHALL NOT BE STEEPER THAN 1:20 (5%). THE ADJACENT SURFACES
AT TRANSITIONS AT CURB RAMPS TO WALKS, GUTTERS, AND STREETS SHALL BE AT THE SAME LEVEL.
88.THE BOTTOM OF DIAGONAL CURB RAMPS SHALL HAVE A CLEAR SPACE 48 INCHES MINIMUM OUTSIDE
ACTIVE TRAFFIC LANES OF THE ROADWAY. DIAGONAL CURB RAMPS PROVIDED AT MARKED CROSSINGS
SHALL PROVIDE THE 48 INCHES MINIMUM CLEAR SPACE WITHIN THE MARKINGS.
89.CURB RAMPS AND BLENDED TRANSITIONS SHALL HAVE DETECTABLE WARNINGS COMPLYING WITH 11B-705
DETECTABLE WARNINGS.
90.RAISED ISLANDS IN CROSSINGS SHALL BE CUT THROUGH LEVEL WITH THE STREET OR HAVE CURB RAMPS AT
BOTH SIDES. THE CLEAR WIDTH OF THE ACCESSIBLE ROUTE AT ISLANDS SHALL BE 60 INCHES WIDE
MINIMUM. WHERE CURB RAMPS ARE PROVIDED, THEY SHALL COMPLY WITH 11B-406 CURB RAMPS, BLENDED
TRANSITIONS AND ISLANDS. LANDINGS COMPLYING WITH 11B-406.5.3 LANDINGS AND THE ACCESSIBLE
ROUTE SHALL BE PERMITTED TO OVERLAP. ISLANDS SHALL HAVE DETECTABLE WARNINGS COMPLYING WITH
11B-705 DETECTABLE WARNINGS AND DETECTABLE DIRECTIONAL TEXTURE.
GENERAL SITE AND BUILDING ELEMENTS
91.WHERE PARKING SPACES ARE PROVIDED, ACCESSIBLE PARKING SPACES SHALL BE PROVIDED IN NUMBER AND
KIND REQUIRED PER SECTION 11B-208 PARKING SPACES.
92.WHERE PASSENGER LOADING ZONES, DROP-OFF ZONES, AND/OR BUS STOPS ARE PROVIDED, ACCESSIBLE
PASSENGER LOADING ZONES, DROP-OFF ZONES, AND/OR BUS STOPS ARE REQUIRED.
93.WHERE ELECTRIC VEHICLE CHARGING STATIONS (EVCS) ARE PROVIDED, THEY SHALL COMPLY WITH SECTION
11B-812 AS REQUIRED BY SECTION 11B-228.3.
94.EVCS COMPLYING WITH SECTION 11B-812 THAT SERVE A PARTICULAR BUILDING OR FACILITY SHALL BE
LOCATED ON AN ACCESSIBLE ROUTE TO AN ENTRANCE COMPLYING WITH SECTION 11B-206.4. WHERE
EVCS DO NOT SERVE A PARTICULAR BUILDING OR FACILITY, EVCS COMPLYING WITH SECTION 11B-812
SHALL BE LOCATED ON AN ACCESSIBLE ROUTE TO AN ACCESSIBLE PEDESTRIAN ENTRANCE OF THE EV
CHARGING FACILITY.
TOILET AND BATHING ROOM CLEARANCES
95.DOORS TO UNISEX TOILET ROOMS AND UNISEX BATHING ROOMS SHALL HAVE PRIVACY LATCHES.
96.MIRRORS LOCATED ABOVE THE LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITHIN THE BOTTOM
EDGE OF THE REFLECTING SURFACE 40 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
MIRRORS NOT LOCATED ABOVE THE LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE
BOTTOM EDGE OF THE REFLECTING SURFACE 35 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR
GROUND.
97.COAT HOOKS SHALL BE LOCATED WITHIN ONE OF THE REACH RANGES SPECIFIED IN SECTION 11B-308.
SHELVES SHALL BE LOCATED 40 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FINISH FLOOR.
MEDICINE CABINETS SHALL BE LOCATED WITH A USABLE SHELF NO HIGHER THAN 44 INCHES MAXIMUM
ABOVE THE FINISH FLOOR.
98.WHERE TOWEL OR SANITARY NAPKIN DISPENSERS, WASTE RECEPTACLES, OR OTHER ACCESSORIES ARE
PROVIDED IN TOILET FACILITIES, AT LEAST ONE OF EACH TYPE SHALL BE LOCATED ON AN ACCESSIBLE
ROUTE. ALL OPERABLE PARTS, INCLUDING COIN SLOTS, SHALL BE 40 INCHES MAXIMUM ABOVE THE FINISH
FLOOR. BABY CHANGING STATIONS ARE NOT REQUIRED TO COMPLY WITH SECTION 11B-603.5 (SEE
EXCEPTION)
WATER CLOSETS AND TOILET COMPARTMENTS
99.FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH CONTROLS SHALL
COMPLY WITH SECTION 11B-309.4 OPERATION EXCEPT THEY SHALL BE LOCATED 44 INCHES MAXIMUM
ABOVE THE FLOOR. FLUSH CONTROLS SHALL BE LOCATED ON THE OPEN SIDE OF THE WATER CLOSET
EXCEPT IN AMBULATORY ACCESSIBLE COMPARTMENTS COMPLYING WITH SECTION 11B-604.8.2
AMBULATORY ACCESSIBLE COMPARTMENTS.
100.TOILET PAPER DISPENSERS SHALL COMPLY WITH SECTION 11B-309.4 OPERATION AND SHALL BE 7 INCHES
MINIMUM AND 9 INCHES MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF
THE DISPENSER. THE OUTLET OF THE DISPENSER SHALL BE BELOW THE GRAB BAR, 19 INCHES MINIMUM
ABOVE THE FINISH FLOOR AND SHALL NOT BE LOCATED BEHIND THE GRAB BARS. DISPENSERS SHALL NOT
BE OF A TYPE THAT CONTROL DELIVERY OR THAT DOES NOT ALLOW CONTINUOUS PAPER FLOW.
101.SANITARY NAPKIN DISPOSAL UNITS, IF PROVIDED, SHALL COMPLY WITH SECTION 11B-309.4 AND SHALL BE
WALL MOUNTED AND LOCATED ON THE SIDEWALL BETWEEN THE REAR WALL OF THE TOILET AND THE
TOILET PAPER DISPENSER, ADJACENT TO THE TOILET PAPER DISPENSER. THE DISPOSAL UNIT SHALL BE
LOCATED BELOW THE GRAB BAR WITH THE OPENING OF THE DISPOSAL UNIT 19 INCHES MINIMUM (483
MM) ABOVE THE FINISH FLOOR.
102.URINALS SHALL BE THE STALL-TYPE OR THE WALL-HUNG TYPE WITH THE RIM 17 INCHES MAXIMUM ABOVE
THE FINISH FLOOR OR GROUND. URINALS SHALL BE 13½ INCHES DEEP MINIMUM MEASURED FROM THE
OUTER FACE OF THE URINAL RIM TO THE BACK OF THE FIXTURE.
103.FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH CONTROLS SHALL
COMPLY WITH SECTION 11B-309 OPERABLE PARTS EXCEPT THAT THE FLUSH CONTROL SHALL BE MOUNTED
AT A MAXIMUM HEIGHT OF 44 INCHES ABOVE THE FINISH FLOOR.
104.FOR LAVATORIES AND SINKS, A CLEAR FLOOR SPACE COMPLYING WITH SECTION 11B-305 CLEAR FLOOR
OR GROUND SURFACES, POSITIONED FOR A FORWARD APPROACH, AND KNEE AND TOE CLEARANCE
COMPLYING WITH SECTION 11B-306 KNEE AND TOE CLEARANCE SHALL BE PROVIDED.
105.LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT OF THE HIGHER OF THE RIM OR COUNTER
SURFACE 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
SIGNS RELATED TO TOILETS AND BATHING FACILITIES
106.ENTRANCES LEADING TO TOILET ROOMS AND BATHING ROOMS COMPLYING WITH 11B-603 TOILET AND
BATHING ROOMS SHALL BE IDENTIFIED BY A GEOMETRIC SYMBOL COMPLYING WITH 11B-703.7.2.6 TOILET
AND BATHING ROOM GEOMETRIC SYMBOLS. WHERE EXISTING TOILET ROOMS OR BATHING ROOMS DO
NOT COMPLY WITH 11B-603 TOILET AND BATHING ROOMS, DIRECTIONAL SIGNS INDICATING THE
LOCATION OF THE NEAREST COMPLIANT TOILET ROOM OR BATHING ROOM WITHIN THE FACILITY SHALL BE
PROVIDED. SIGNS SHALL COMPLY WITH 11B-703.5 VISUAL CHARACTERS AND SHALL INCLUDE THE
INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH 11B-703.7.2.1 ISA. WHERE EXISTING TOILET
ROOMS OR BATHING ROOMS DO NOT COMPLY WITH 11B-603 TOILET AND BATHING ROOMS, THE TOILET
ROOMS OR BATHING ROOMS COMPLYING WITH 11B-603 TOILET AND BATHING ROOMS SHALL BE
IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH 11B-703.7.2.1 ISA.
WHERE CLUSTERED SINGLE USER TOILET ROOMS OR BATHING FACILITIES ARE PERMITTED TO USE
EXCEPTIONS TO 11B-213.2 TOILET AND BATHING ROOMS, TOILET ROOMS OR BATHING FACILITIES
COMPLYING WITH 11B-603 TOILET AND BATHING ROOMS SHALL BE IDENTIFIED BY THE INTERNATIONAL
SYMBOL OF ACCESSIBILITY COMPLYING WITH 11B-703.7.2.1 ISA UNLESS ALL TOILET ROOMS AND BATHING
FACILITIES COMPLY WITH 11B-603 TOILET AND BATHING ROOMS. EXISTING BUILDINGS THAT HAVE BEEN
REMODELED TO PROVIDE SPECIFIC TOILET ROOMS OR BATHING ROOMS FOR PUBLIC USE THAT COMPLY
WITH THESE BUILDING STANDARDS SHALL HAVE THE LOCATION OF AND THE DIRECTIONS TO THESE
ROOMS POSTED IN OR NEAR THE BUILDING LOBBY OR ENTRANCE ON A SIGN COMPLYING WITH
11B-703.5 VISUAL CHARACTERS, INCLUDING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING
WITH 11B-703.7.2.1 ISA.
107.PICTOGRAMS SHALL COMPLY WITH THE FOLLOWING:
a.PICTOGRAMS SHALL HAVE A FIELD HEIGHT OF 6 INCHES MINIMUM. CHARACTERS AND BRAILLE SHALL
NOT BE LOCATED IN THE PICTOGRAM FIELD.
b.PICTOGRAMS AND THEIR FIELD SHALL HAVE A NON-GLARE FINISH. PICTOGRAMS SHALL CONTRAST WITH
THEIR FIELD WITH EITHER A LIGHT PICTOGRAM ON A DARK FIELD OR A DARK PICTOGRAM ON A LIGHT
FIELD.
c.PICTOGRAMS SHALL HAVE TEXT DESCRIPTORS LOCATED DIRECTLY BELOW THE PICTOGRAM FIELD. TEXT
DESCRIPTORS SHALL COMPLY WITH 11B-703.2 RAISED CHARACTERS, 11B-703.3 BRAILLE AND 11B-703.4
INSTALLATION HEIGHT AND LOCATION.
d.THE INSTALLATION HEIGHT AND LOCATION OF PICTOGRAM SIGNS SHALL BE PER 11B-703.4.1.
116.SYMBOLS SHALL COMPLY WITH THE FOLLOWING:
a.DOORWAYS LEADING TO TOILET ROOMS AND BATHING ROOMS SHALL BE IDENTIFIED BY A GEOMETRIC
SYMBOL COMPLYING WITH 11B-703.7.2.6 TOILET AND BATHING FACILITIES GEOMETRIC SYMBOLS. THE
SYMBOL SHALL BE MOUNTED AT 58 INCHES MINIMUM AND 60 INCHES MAXIMUM ABOVE THE FINISH
FLOOR OR GROUND SURFACE MEASURED FROM THE CENTERLINE OF THE SYMBOL. WHERE A DOOR IS
PROVIDED, THE SYMBOL SHALL BE MOUNTED WITHIN 1 INCH OF THE VERTICAL CENTERLINE OF THE
DOOR. 11B-703.7.2.6 (SEE EXCEPTION)
b.A TRIANGLE SYMBOL SHALL BE LOCATED AT ENTRANCES TO MEN’S TOILET AND BATHING FACILITIES
AND IT SHALL BE IDENTIFIED BY AN EQUILATERAL TRIANGLE, ¼ INCH THICK WITH EDGES 12 INCHES
LONG AND A VERTEX POINTING UPWARD. THE TRIANGLE SYMBOL SHALL CONTRAST WITH THE DOOR,
EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND.
c.A CIRCLE SYMBOL SHALL BE LOCATED AT ENTRANCES TO WOMEN’S TOILET AND BATHING FACILITIES
AND IT SHALL BE IDENTIFIED BY A CIRCLE, ¼ INCH THICK AND 12 INCHES IN DIAMETER. THE CIRCLE
SYMBOL SHALL CONTRAST WITH THE DOOR, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A
LIGHT BACKGROUND.
d.A COMBINED CIRCLE AND TRIANGLE SYMBOL SHALL BE LOCATED AT ENTRANCES TO UNISEX TOILET AND
BATHING FACILITIES AND IT SHALL BE SHALL BE IDENTIFIED BY A CIRCLE, ¼ INCH THICK AND 12 INCHES
IN DIAMETER WITH A ¼ INCH THICK TRIANGLE WITH A VERTEX POINTING UPWARD SUPERIMPOSED ON
THE CIRCLE AND WITHIN THE 12-INCH DIAMETER. THE TRIANGLE SYMBOL SHALL CONTRAST WITH THE
CIRCLE SYMBOL, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. THE
CIRCLE SYMBOL SHALL CONTRAST WITH THE DOOR, EITHER LIGHT ON A DARK BACKGROUND OR DARK
ON A LIGHT BACKGROUND.
FIRE ALARM SYSTEMS
117.WHERE FIRE ALARM SYSTEMS AND CARBON MONOXIDE ALARM SYSTEMS PROVIDE AUDIBLE ALARM
COVERAGE, ALARMS SHALL COMPLY WITH 11B-215 FIRE ALARM SYSTEMS. §11B-215.1 (SEE EXCEPTION)
118.ALARMS IN PUBLIC USE AREAS AND COMMON USE AREAS SHALL COMPLY WITH 702 CHAPTER 9, SECTION
907.5.2.3.1.
119.WHERE EMPLOYEE WORK AREAS HAVE AUDIBLE ALARM COVERAGE, THE WIRING SYSTEM SHALL BE DESIGNED
SO THAT VISIBLE ALARMS COMPLYING WITH 702 CHAPTER 9, SECTION 907.5.2.3.2 CAN BE INTEGRATED
INTO THE ALARM SYSTEM.
120.FIRE ALARM SYSTEMS SHALL HAVE PERMANENTLY INSTALLED AUDIBLE AND VISIBLE ALARMS COMPLYING WITH
NFPA 72 (1999 OR 2002 EDITION) (INCORPORATED BY REFERENCE, SEE “REFERENCED STANDARDS” IN
CHAPTER 1), EXCEPT THAT THE MAXIMUM ALLOWABLE SOUND LEVEL OF AUDIBLE NOTIFICATION
APPLIANCES COMPLYING WITH SECTION 4-3.2.1 OF NFPA 72 (1999 EDITION) SHALL HAVE A SOUND LEVEL
NO MORE THAN 110 DB AT THE MINIMUM HEARING DISTANCE FROM THE AUDIBLE APPLIANCE. IN
ADDITION, ALARMS IN GUEST ROOMS REQUIRED TO PROVIDE COMMUNICATION FEATURES SHALL COMPLY
WITH SECTIONS 4-3 AND 4-4 OF NFPA 72 (1999 EDITION) OR SECTIONS 7.4 AND 7.5 OF NFPA 72 (2002
EDITION), AND CHAPTER 9, SECTIONS 907.5.2.1 AND 907.5.2.3.
ASSISTED LISTENING SYSTEMS
121.ASSISTIVE LISTENING SYSTEMS SHALL BE PROVIDED IN ASSEMBLY AREAS, INCLUDING CONFERENCE AND
MEETING ROOMS, USED FOR THE PURPOSE OF ENTERTAINMENT, EDUCATIONAL OR CIVIC GATHERINGS,
OR SIMILAR PURPOSES.
NOTE: ASSEMBLY AREAS INCLUDE, BUT ARE NOT LIMITED TO, CLASSROOMS, LECTURE HALLS,
COURTROOMS, PUBLIC MEETING ROOMS, PUBLIC HEARING ROOMS, LEGISLATIVE CHAMBERS, MOTION
PICTURE HOUSES, AUDITORIA, THEATERS, PLAYHOUSES, DINNER THEATERS, CONCERT HALLS, CENTERS FOR
THE PERFORMING ARTS, AMPHITHEATERS, ARENAS, STADIUMS, GRANDSTANDS, OR CONVENTION CENTERS.
122.ASSISTIVE LISTENING SYSTEM SHALL PROVIDE AN AMPLIFICATION SYSTEM UTILIZING TRANSMITTERS,
RECEIVERS, AND COUPLING DEVICES TO BYPASS THE ACOUSTICAL SPACE BETWEEN A SOUND SOURCE AND
A LISTENER BY MEANS OF INDUCTION LOOP, RADIO FREQUENCY, INFRARED, OR DIRECT-WIRED
EQUIPMENT.
123.WHERE A BUILDING CONTAINS MORE THAN ONE ASSEMBLY AREA UNDER ONE MANAGEMENT, THE TOTAL
NUMBER OF REQUIRED RECEIVERS MAY BE CALCULATED USING THE TOTAL NUMBER OF SEATS IN THE
ASSEMBLY AREAS PROVIDED THAT ALL RECEIVERS ARE USABLE WITH ALL SYSTEMS. 11B-219.3 (SEE EXCEPTION)
124.TWENTY-FIVE PERCENT MINIMUM OF RECEIVERS PROVIDED FOR ASSISTIVE LISTENING SYSTEMS, BUT NO
FEWER THAN TWO, SHALL BE HEARING-AID COMPATIBLE EXCEPT WHEN ALL SEATS IN AN ASSEMBLY AREA ARE
SERVED BY MEANS OF AN INDUCTION LOOP.
125.WHEN ASSISTIVE-LISTENING SYSTEMS ARE LIMITED TO SPECIFIC AREAS OR SEATS, SUCH AREAS OR SEATS
SHALL BE WITHIN A 50-FOOT VIEWING DISTANCE OF THE STAGE OR PLAYING AREA AND SHALL HAVE A
COMPLETE VIEW OF THE STAGE OR PLAYING AREA.
126.PERMANENTLY INSTALLED ASSISTIVE-LISTENING SYSTEMS ARE REQUIRED IN AREAS IF (1) THEY HAVE FIXED
SEATING AND (2A) THEY ACCOMMODATE AT LEAST 50 PERSONS OR (2B) THEY HAVE AUDIO-AMPLIFICATION
SYSTEMS, EXCEPT THOSE USED EXCLUSIVELY FOR PAGING AND/OR BACKGROUND MUSIC.
127.PORTABLE ASSISTIVE-LISTENING SYSTEMS MAY SERVE MORE THAN ONE CONFERENCE OR MEETING ROOMS
IF AN ADEQUATE NUMBER OF ELECTRICAL OUTLETS OR OTHER SUPPLEMENTARY WIRING IS PROVIDED AND
PERMANENTLY INSTALLED SYSTEMS ARE NOT REQUIRED.
128.RECEIVERS REQUIRED FOR USE WITH AN ASSISTIVE LISTENING SYSTEM SHALL INCLUDE A 1/8 INCH
STANDARD MONO JACK.
129.RECEIVERS REQUIRED TO BE HEARING AID COMPATIBLE SHALL INTERFACE WITH TELECOILS IN HEARING AIDS
THROUGH THE PROVISION OF NECK LOOPS.
130.ASSISTIVE LISTENING SYSTEMS SHALL BE CAPABLE OF PROVIDING A SOUND PRESSURE LEVEL FROM 110 – 118
DB WITH A DYNAMIC RANGE ON THE VOLUME CONTROL OF 50 DB.
131.SIGNAL-TO-NOISE RATIO FOR INTERNALLY GENERATED NOISE IN ASSISTIVE LISTENING SYSTEMS SHALL BE 18
DB MINIMUM.
132.PEAK CLIPPING SHALL NOT EXCEED 18 DB OF CLIPPING RELATIVE TO THE PEAKS OF SPEECH.
Sheet Title:
ISSUE DATE
ISSUE FOR PLANCHECK 12.22.2025
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ENGINEER/CONSULTANT
ARCHITECT/ENGINEER STAMP
30
5
W
4
T
H
S
T
R
E
E
T
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
1
CA
F
E
OA
S
I
S
CLIENT
www.madstudiola.com
CITY STAMP
Project Director:
Project Designer:
Project Tech:
Project No:25030.300E.M.
E.M.
S.P.
ISSUED FOR MEP 01.13.2026
ISSUED FOR PLAN CHECK COMMENTS- PLANNING DEPT.01.22.2026
ISSUED FOR PRICING 02.17.2026
ISSUED FOR PLAN CHECK COMMENTS - PLANNING DEPT.02.20.2026
ISSUED FOR COUNTY REVIEW 03.24.2026
ISSUED FOR ADDENDUM A 03.27.2026
ISSUED FOR BUILDING DEPT REVIEW 04.08.2026
ISSUED FOR BUILDING DEPT REVIEW - RESUBMITTAL 05.05.2026
ISSUED FOR BUILDING DEPT CORRECTIONS 05.20.2026
ID0.3
ACCESSIBILITY NOTES
1
SCALE
N.T.S.ACCESSIBILITY SYMBOL
INTERNATIONAL SYMBOL OF ACCESSIBILITY DISPLAYED AT
PRIMARY ENTRANCE
SYMBOL PROPORTIONS
SCALE
1/2" = 1'-0"ACCESSIBLE DOOR CONSTRUCTION
RUBBER BUMPER
ON CHAIR
10
"
M
I
N
I
M
U
M
BO
T
T
O
M
R
A
I
L
1/
4
"
M
A
X
.
1/
2
"
M
A
X
.
AT
1
:
2
S
L
O
P
E
1
2
3
SCALE
NTSEXISTING SITEPLAN/PATH OF TRAVEL - FOR INFORMATION ONLY
NO
R
T
H
B
R
O
A
D
W
A
Y
WEST 4TH STREET
STREET LIGHT FIRE HYDRANT
APN: 398-255-20
STREET LIGHT
EXISTING ACCESSIBLE
ROUTE, SEE DETAIL 3
(E)BACK FLOW DEVICE
2” WILKINS 975 XL2
SERIAL # ACP6882
4
DN
UP
DN
UP
UP
(E) WOMENS
RESTROOM
104OFFICE
111
OFFICE
110
(E) MENS
RESTROOM
103
(E) OPEN
OFFICE
106
(E)
EXIT CORRIDOR
-
Sheet Title:
ISSUE DATE
ISSUE FOR PLANCHECK 12.22.2025
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ENGINEER/CONSULTANT
ARCHITECT/ENGINEER STAMP
30
5
W
4
T
H
S
T
R
E
E
T
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
1
CA
F
E
OA
S
I
S
CLIENT
www.madstudiola.com
CITY STAMP
Project Director:
Project Designer:
Project Tech:
Project No:25030.300E.M.
E.M.
S.P.
ISSUED FOR MEP 01.13.2026
ISSUED FOR PLAN CHECK COMMENTS- PLANNING DEPT.01.22.2026
ISSUED FOR PRICING 02.17.2026
ISSUED FOR PLAN CHECK COMMENTS - PLANNING DEPT.02.20.2026
ISSUED FOR COUNTY REVIEW 03.24.2026
ISSUED FOR ADDENDUM A 03.27.2026
ISSUED FOR BUILDING DEPT REVIEW 04.08.2026
ISSUED FOR BUILDING DEPT REVIEW - RESUBMITTAL 05.05.2026
ISSUED FOR BUILDING DEPT CORRECTIONS 05.20.2026
ID0.5
EXISTING SITE PLAN/
PATH OR TRAVEL
(FOR INFORMATION ONLY)
10
19
SCALE
3/8" = 1'-0"ACCESSIBLE MOUNTING HEIGHTS
PAPER
TOWEL/
TRASH
RECEPTACLE
40
"
M
A
X
.
2'
-
0
"
1'
-
7
"
MA
X
.
HAND
DRYER
TOILET SEAT
COVER
DISPENSER
SANITARY
NAPKIN
DISPOSAL
TOILET
PAPER
DISPENSER
MIRROR
2'
-
9
"
VARIES
GRAB BAR
SOAP
DISPENSER
SCALE
3/8" = 1'-0"ACCESSIBLE LAVATORY
48" MIN.
NOTE:
1.OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE
TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. FORCE REQUIRED TO
ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS MAXIMUM.
2.OPERABLE PARTS SHALL NOT BE FURTHER BACK FROM THE FRONT EDGE OF THE
LAVATORY COUNTER THAN THE THE WHEEL CHAIR SPACE IS ALLOWED TO EXTEND
BELOW.
30
"
MI
N
18
"
MI
N
.
PLAN VIEWSECTION VIEW
17" MIN.
19" MAX.
9"
MI
N
.
8"MIN.
KNEE
CLR.
11"
MIN.
34
"
M
A
X
.
29
"
M
I
N
.
27
"
M
I
N
.
CLEAR
FLOOR
SPACE
BOTTOM OF REFLECTIVE MIRROR
SURFACE SHALL BE AT 40" AFF
MAXIMUM HEIGHT
17" MIN.
19" MAX.
44
"
M
A
X
.
HE
I
G
H
T
O
F
OP
E
R
A
B
L
E
PA
R
T
S
KNEE CLEARANCE IS REDUCED 1"
IN DEPTH FOR 6" IN HEIGHT
BETWEEN 9" TO 27" AFF.
6"
MAX.
PROVIDE INSULATION OR
OTHER PROTECTION AT HOT
WATER SUPPLY AND DRAIN
PIPES.
SEE
NOTE 2
ABOVE
SCALE
3/8" = 1'-0"ACCESSIBLE WATER CLOSET
36" MIN.
24"MIN.12"
MIN.
33
"
-
3
6
"
33
"
-
3
6
"
17
"
-
1
9
"
7" TO 9"
WATER CLOSET FLOOR OR
WALLMOUNTED
17" TO 18"
19
"
M
I
N
.
CL
TRANSFER SIDE
SIDE WALL ELEVATION
24" MIN.
REAR WALL ELEVATION
NOTE:
1.GRAB BARS TO BE -1/4" TO 1-1/2" CLEARANCE TO FINISH
WALL.
2.GRAB BARS SHALL HAVE BACKING AND BE DESIGNED TO
SUPPORT A 250 POUND POINT LOAD.
3.FLUSH CONTROLS SHALL BE ACCESSIBLE FROM THE WIDE
SISE OF THE TOILET.
4.FLOOR TO SLOPE 1/2" PER FOOT MAX. IN ANY DIRECTION.
5.FLOOR SURFACE TO BE NON-SLIP.
1 1/2"
42" MIN.
AL
L
D
I
S
P
E
N
S
E
R
S
4
0
"
MA
X
.
T
O
H
I
G
H
E
S
T
OP
E
R
A
B
L
E
P
A
R
T
12"
MAX.
33
"
-
3
6
"
A.
F
.
F
.
T
O
T
O
P
OF
G
R
A
B
B
A
R
1-1/4"Ø TO
1-1/2"Ø
SCALE
3/8" = 1'-0"ACCESSIBLE URINAL
PLAN VIEWSECTION VIEW
48" MIN.
2'-0"
14" MIN.
1'
-
0
"
SE
E
E
L
E
V
A
T
I
O
N
URINAL
PARTITION
CLEAR
FLOOR
SPACE30
"
M
I
N
.
17
"
MA
X
.
44
"
M
A
X
.
FLUSH VALVE
RIM
18
"
MI
N
.
24"
MAX.
36
"
M
I
N
.
311
SCALE
1/4" = 1'-0"EXIST. MEN'S & WOMEN'S RESTROOM PLAN (FOR INFORMATION ONLY)
7'-3"
7'
-
1
1
"
7'
-
0
"
7'-2"
7'
-
5
"
8'
-
4
"
2'-0"
11"
9"5'-0"
5'-0"
48" x 60"
CLR.
1'-6"
1'-6"
1'-8"
1'-8"
30" x 48"
CLR.
30" x 48"
CLR.
7
SCALE
NTSACCESSIBLE RESTROOM IDENTIFICATION
58
"
M
I
N
.
A
N
D
6
0
"
M
A
X
.
FLR. FIN.
CL
18" MIN.
18
"
M
I
N
.
X:
6
0
"
M
A
X
.
(S
E
E
D
E
T
.
'
B
'
)
Y:
4
8
"
M
I
N
.
(S
E
E
D
E
T
.
'
B
'
)
EQ EQTACTILE SIGNAGE
CENTERED ON TACTILE
CHARACTERS
58
"
M
I
N
.
A
N
D
6
0
"
M
A
X
.
FLR. FIN.
CLRESTROOM
X:
6
0
"
M
A
X
.
(S
E
E
D
E
T
.
'
B
'
)
Y:
4
8
"
M
I
N
.
(S
E
E
D
E
T
.
'
B
'
)
(PLAN)
UNISEX (ELEV.)MENS/WOMENS (ELEV.)
UNISEX
RESTROOM
REFER TO
GEOMETRIC SYMBOLS
REFER TO
'TACTILE/BRAILLE
SIGNAGE'
(WOMEN)
(MEN)
WITHIN 1"
L(C OF DOOR AT
EITHER SIDE)
UNISEX
RESTROOM
BASELINE OF THE
LOWEST BRAILLE
CELLS
BASELINE OF THE
HIGHEST LINE OF
RAISED
CHARACTERS
X: 60" MAX.
C OF SIGNL
TACTILE/BRAILLE SIGNAGEGEOMETRIC SYMBOLS
LC OF SIGN.
SEE DETAIL 'A'
(UNISEX)
CL
1'
-
0
"
1'
-
0
"
1'-
0
"
1'-0"
Y: 48" MAX.
1.PICTOGRAMS NOT REQUIRED ON SYMBOLS OR TACTILE SIGNAGE.
2.GENDER SPECIFIC GEOMETRIC SYMBOLS (I.E. MEN, WOMEN) APPLY ONLY TO MULTI-ACCOMMODATION
RESTROOMS. A SANITARY FACILITY THAT IS NOT SPECIFICALLY IDENTIFIED AS FOR "MEN" OR "WOMEN"
SHALL BE IDENTIFIED AS A "UNISEX" FACILITY. THE "UNISEX" SYMBOL IS THE ONLY SPECIFIC INDICATOR
REQUIRED TO BE PROVIDED BY CHAPTER 11B FOR A TOILET FACILITY THAT IS AVAILABLE FOR USE BY ALL
INDIVIDUALS. NO PICTOGRAM, TEXT, OR BRAILLE IS REQUIRED ON THE SYMBOL.
3.PROVIDE TACTILE/BRAILLE SIGNAGE: USER SIGN STATEMENT AS - "UNISEX RESTROOM", "ALL GENDER
RESTROOM", "RESTROOM", "MEN", "WOMEN".
REFER TO
GEOMETRIC SYMBOLS
REFER TO
'TACTILE/BRAILLE
SIGNAGE'
Sheet Title:
ISSUE DATE
ISSUE FOR PLANCHECK 12.22.2025
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ENGINEER/CONSULTANT
ARCHITECT/ENGINEER STAMP
30
5
W
4
T
H
S
T
R
E
E
T
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
1
CA
F
E
OA
S
I
S
CLIENT
www.madstudiola.com
CITY STAMP
Project Director:
Project Designer:
Project Tech:
Project No:25030.300E.M.
E.M.
S.P.
ISSUED FOR MEP 01.13.2026
ISSUED FOR PLAN CHECK COMMENTS- PLANNING DEPT.01.22.2026
ISSUED FOR PRICING 02.17.2026
ISSUED FOR PLAN CHECK COMMENTS - PLANNING DEPT.02.20.2026
ISSUED FOR COUNTY REVIEW 03.24.2026
ISSUED FOR ADDENDUM A 03.27.2026
ISSUED FOR BUILDING DEPT REVIEW 04.08.2026
ISSUED FOR BUILDING DEPT REVIEW - RESUBMITTAL 05.05.2026
ISSUED FOR BUILDING DEPT CORRECTIONS 05.20.2026
ID0.6
EXISTING RESTROOMS
(FOR INFORMATION ONLY)
DN
DN
UP
DN
UP
EXISTING STAIRS, HANDRAILS &
GUARDRAILS
MATCH EXISTING
GUARDRAIL
EXISTING STAIRS, HANDRAILS &
GUARDRAILS
EXISTING
SHAFT
OPEN TO BELOW
OPEN TO BELOW
(E)
OPEN OFFICE
-
DN
DN
CNTR TOP W/ BAR SINK W/
GARB. DISP & UNDERCOUNTER
REFIG.
EXISTING
SHAFT
EXISTING STAIR, HANDRAIL &
GUARDRAIL
EXISTING
SHAFT
EXISTING STAIR, HANDRAIL &
GUARDRAIL
OPEN TO BELOW
OPEN TO BELOW
(E)
OPEN OFFICE
-
(E)
OPEN OFFICE
-
TC
S
(E)
STORAGE
-
(E)
BREAK ROOM
-
(E)
MEN'S
-
(E)
WOMEN'S
-
(E)
STORAGE
-
DN
UP
DN
UP
UP
(E) WOMENS
RESTROOM
104OFFICE
111
OFFICE
110
(E) MENS
RESTROOM
103
(E) OPEN
OFFICE
106
(E)
EXIT CORRIDOR
-
10
3
CAFE
101
BOH
102
LOBBY
100
105
STORAGE
105
11
0
91
'
-
0
"
TR
A
V
E
L
D
I
S
T
A
N
C
E
(
+
C
P
o
f
E
)
32
'
-
0
"
C
O
M
M
O
N
PA
T
H
O
F
E
G
R
E
S
S
33'-0" COMMON
PATH OF EGRESS
61
'
-
0
"
C
O
M
M
O
N
PA
T
H
O
F
E
G
R
E
S
S
81
'
-
0
"
(
T
O
T
A
L
D
I
S
T
A
N
C
E
T
R
A
V
E
L
E
D
:
1
1
3
'
-
0
"
)
TR
A
V
E
L
D
I
S
T
A
N
C
E
(
+
C
P
o
f
E
)
3'
-
0
"
3'-0"
OL:31
MIN. WIDTH: 32"
3'-0"
OC:32
MIN. WIDTH: 32"
88
'
-
0
"
(
T
O
T
A
L
D
I
S
T
A
N
C
E
T
R
A
V
E
L
E
D
:
2
1
1
'
-
0
"
)
TR
A
V
E
L
D
I
S
T
A
N
C
E
(
+
C
P
o
f
E
)
ALL TOTAL DISTANCE TRAVELED
<300' PER CBC TABLE 1017.2
EXISTING LIGHT WELL
67
'
-
0
"
(
T
O
T
A
L
D
I
S
T
A
N
C
E
T
R
A
V
E
L
E
D
:
1
2
8
'
-
0
"
)
TR
A
V
E
L
D
I
S
T
A
N
C
E
(
+
C
P
o
f
E
)
59
'
-
0
"
(
T
O
T
A
L
D
I
S
T
A
N
C
E
T
R
A
V
E
L
E
D
:
9
2
'
-
0
"
)
TR
A
V
E
L
D
I
S
T
A
N
C
E
(
+
C
P
o
f
E
)
Sheet Title:
ISSUE DATE
ISSUE FOR PLANCHECK 12.22.2025
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ENGINEER/CONSULTANT
ARCHITECT/ENGINEER STAMP
30
5
W
4
T
H
S
T
R
E
E
T
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
1
CA
F
E
OA
S
I
S
CLIENT
www.madstudiola.com
CITY STAMP
Project Director:
Project Designer:
Project Tech:
Project No:25030.300E.M.
E.M.
S.P.
ISSUED FOR MEP 01.13.2026
ISSUED FOR PLAN CHECK COMMENTS- PLANNING DEPT.01.22.2026
ISSUED FOR PRICING 02.17.2026
ISSUED FOR PLAN CHECK COMMENTS - PLANNING DEPT.02.20.2026
ISSUED FOR COUNTY REVIEW 03.24.2026
ISSUED FOR ADDENDUM A 03.27.2026
ISSUED FOR BUILDING DEPT REVIEW 04.08.2026
ISSUED FOR BUILDING DEPT REVIEW - RESUBMITTAL 05.05.2026
ISSUED FOR BUILDING DEPT CORRECTIONS 05.20.2026
KEYNOTESSHEET NOTES OCCUPANCY ANALYSIS
1.ALL AISLES SERVING AS THE PATH OF EGRESS ACCESS IN THE MEANS OF EGRESS SYSTEMS SHALL COMPLY
WITH THE REQUIREMENTS OF THE 2022 CBC CHAPTER 10. THE MINIMUM CLEAR WIDTH OF ALL AISLES IS
44" CLEAR.
2.EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, TOOL, OR SPECIAL
KNOWLEDGE OR EFFORT. SPECIAL LOCKING DEVICES SHALL BE AN APPROVED TYPE (CBC CHAPTER 10).
3.EXIT DOORS SHALL SWING IN THE DIRECTION OF PATH OF TRAVEL WHEN SERVING AN OCCUPANT LOAD
OF MORE THAN 49 OCCUPANTS (CBC CHAPTER 10).
4.TWO (2) EXITS ARE REQUIRED WHEN SERVING AN OCCUPANT LOAD OF MORE THAN 49 OCCUPANTS (CBC
CHAPTER 10).
5.THE MINIMUM CLEAR WIDTH OF A DOOR SHALL NOT BE LESS THAN 32" (CBC CHAPTER 10).
6.EGRESS SHALL NOT PASS THROUGH KITCHENS, STORAGE ROOMS, CLOSETS OR SPACES USED FOR SIMILAR
PURPOSES.
7.COMMON PATH OF EGRESS TRAVEL IN GROUP B SHALL BE A MAXIMUM OF 75 FEET, OR A MAXIMUM OF
100 FEET IF THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRIINKLER SYSTEM (CBC
CHAPTER 10).
8.EXIT ACCESS TRAVEL DISTANCE IN GROUP B SHALL BE A MAXIMUM OF 200 FEET OR A MAXIMUM OF 300
FEET IF THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM (CBC CHAPTER
10).
9.DEAD ENDS IN CORRIDORS IN GROUP B SHALL NOT EXCEED 20 FEET, OR 50 FEET IF THE BUILDING IS
EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM (CBC CHAPTER 10).
10.MEANS OF EGRESS SHALL BE ILLUMINATED AT A MINIMUM INTENSITY OF 1 FOOT-CANDLE AT THE FLOOR
LEVEL.
11.MEANS OF EGRESS ILLUMINATION SHALL BE PROVIDED FROM AN EMERGENCY POWER SYSTEM.
EXISTING 'B' OCCUPANCY TO REMAIN, NO CHANGE IN USE.
SECOND LEVEL 1,928 S.F. @ 150 GROSS = 13 OCC.
MEZZANINE LEVEL 491 S.F. @ 150 GROSS = 03 OCC.
FIRST LEVEL 1,903 S.F. @ 150 GROSS = 13 OCC.
LOBBY ASSEMBLY 313 S.F. @ 15 GROSS = 20 OCC.
BASEMENT LEVEL 2,057 S.F. @ 150 GROSS = 14 OCC.
EXITS REQUIRED: 2
EXITS PROVIDED: 2
TOTAL - (±) 6,461 S.F. = 63 OCC.
1 PER CURRENT CBC EXCEPTION 303.1.2 SMALL ASSEMBLY SPACES.
THE FOLLOWING ROOMS AND SPACES SHALL NOT BE CLASSIFIED AS ASSEMBLY OCCUPANCIES
ID0.7
OCCUPANCY & EGRESS
PLAN
SCALE :
NORTH
OCCUPANCY AND EGRESS PLAN
1/8" = 1'-0"
SCALE :
NORTH
(E) SECOND FLR - (NIC)
1/8" = 1'-0"SCALE :
NORTH
(E) MEZZANINE - (NIC)
1/8" = 1'-0"SCALE :
NORTH
FIRST FLOOR
1/8" = 1'-0"SCALE :
NORTH
(E) BASEMENT - (NIC)
1/8" = 1'-0"
EXISTING 'B' OCCUPANCY TO REMAIN, NO CHANGE IN USE.
SUITE 100 - SECOND LEVEL 1,928 S.F. @ 150 GROSS = 13 OCC.
EXISTING 'B' OCCUPANCY TO REMAIN, NO CHANGE IN USE.
SUITE 100 - MEZZANINE LEVEL 491 S.F. @ 150 GROSS = 03 OCC.
EXISTING 'B' OCCUPANCY TO REMAIN, NO CHANGE IN USE.
FIRST LEVEL 1,903 S.F. @ 150 GROSS = 13 OCC.
LOBBY ASSEMBLY 313 S.F. @ 15 GROSS = 20 OCC.
TOTAL - (±) 2,216 S.F. = 33 OCC.
EXISTING 'B' OCCUPANCY TO REMAIN, NO CHANGE IN USE.
SUITE 100 - BASEMENT LEVEL 2,057 S.F. @ 150 GROSS = 14 OCC.
CAFE SEATING AREA AT LOBBY - (±) 215 S.F. <10% OF TOTAL FLOOR AREA
TOTAL 1ST FLOOR AREA - (±) 2,216 S.F.
DN
UP
DN
UP
UP
(E) WOMENS
RESTROOM
104OFFICE
111
OFFICE
110
(E) MENS
RESTROOM
103
(E) OPEN
OFFICE
106
(E)
EXIT CORRIDOR
-
(D)
(D)(D)
(D)
(E)
(E)
(E)
(E)
(E)
(E)
DN
UP
DN
UP
UP
(E) WOMENS
RESTROOM
104OFFICE
111
OFFICE
110
(E) MENS
RESTROOM
103
(E) OPEN
OFFICE
106
(E)
EXIT CORRIDOR
-
OPEN TO
ABOVE
(E)
(E)
(D)
DN
UP
DN
UP
UP
(E) WOMENS
RESTROOM
104OFFICE
111
OFFICE
110
(E) MENS
RESTROOM
103
(E) OPEN
OFFICE
106
(E)
EXIT CORRIDOR
-
DN
UP
DN
UP
UP
(E) WOMENS
RESTROOM
104OFFICE
111
OFFICE
110
(E) MENS
RESTROOM
103
(E) OPEN
OFFICE
106
(E)
EXIT CORRIDOR
-
(E)
(E)
Sheet Title:
ISSUE DATE
ISSUE FOR PLANCHECK 12.22.2025
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ENGINEER/CONSULTANT
ARCHITECT/ENGINEER STAMP
30
5
W
4
T
H
S
T
R
E
E
T
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
1
CA
F
E
OA
S
I
S
CLIENT
www.madstudiola.com
CITY STAMP
Project Director:
Project Designer:
Project Tech:
Project No:25030.300E.M.
E.M.
S.P.
ISSUED FOR MEP 01.13.2026
ISSUED FOR PLAN CHECK COMMENTS- PLANNING DEPT.01.22.2026
ISSUED FOR PRICING 02.17.2026
ISSUED FOR PLAN CHECK COMMENTS - PLANNING DEPT.02.20.2026
ISSUED FOR COUNTY REVIEW 03.24.2026
ISSUED FOR ADDENDUM A 03.27.2026
ISSUED FOR BUILDING DEPT REVIEW 04.08.2026
ISSUED FOR BUILDING DEPT REVIEW - RESUBMITTAL 05.05.2026
ISSUED FOR BUILDING DEPT CORRECTIONS 05.20.2026
KEYNOTESSHEET NOTES LEGEND
1.REFER TO SHEET ID0.1 FOR GENERAL DEMOLITION NOTES.
2.REFER TO PARTITION PLAN FOR EXTENT OF DEMOLITION.
3.REFER TO ENGINEER'S DRAWINGS FOR ADDITIONAL DEMOLITION SCOPE.
4.THE GENERAL CONTRACTOR SHALL VISIT AND WALK THE PROJECT SITE PRIOR TO DETERMINING THE EXTENT
OF DEMOLITION WORK TO BE DONE.
5.ALL TRADES TO INSPECT EXISTING SITE CONDITIONS PRIOR TO SUBMITTING BIDS. CONTRACTOR TO NOTIFY
MAD OF ANY CONFLICT BETWEEN EXISTING CONDITIONS AND THE DRAWINGS.
6.THE GENERAL CONTRACTOR SHALL PATCH AND REPAIR EXISTING WALLS TO REMAIN WHERE DEMOLITION
OCCURS AND PREP WALLS TO RECEIVE NEW FINISHES AS INDICATED ON FINISH PLAN(S) AND/OR
SCHEDULE(S).
7.ALL DEMOLISHED DOORS, FRAMES AND DOOR HARDWARE TO BE SAVED AND STORED FOR POSSIBLE RE-USE.
8.ALL EXISTING POWER AND DATA RECEPTACLES AND ASSOCIATED WIRING ARE TO REMAIN, U.O.N. THE
GENERAL CONTRACTOR SHALL VERIFY IN THE FIELD THE LOCATION AND FUNCTIONAL CAPACITY OF ALL
EXISTING TO REMAIN OUTLETS AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BETWEEN THE
DRAWINGS AND EXISTING CONDITIONS.
9.WHERE PARTITIONS ARE DEMOLISHED, REMOVE ALL TELEPHONE, POWER, DATA RECEPTACLES, ETC AND ALL
ASSOCIATED WIRING ALL THE WAY BACK TO THE ORIGINATING SOURCE.
10.WHERE EXISTING PLUMBING FIXTURES ARE REMOVED, CAP-OFF EXISTING PLUMBING LINES AT THE SOURCE.
11.ALL EXISTING FLOOR CORES AND ASSOCIATED WIRING NOTED TO BE REMOVED SHALL BE TERMINATED ALL
THE WAY BACK TO ITS ORIGINATING SOURCE. FILL-IN CONCRETE SLAB WHERE OUTLETS ARE REMOVED.
12.GENERAL CONTRACTOR TO VERIFY EXISTING WALL BASE HEIGHT AND SKIM WALL AS REQUIRED TO RECEIVE
NEW WALL BASE.
13.IN ALL AREAS WHERE DEMOLITION (REMOVAL OF TILE, CARPETING, TACKLESS, PARTITIONS, ETC.) CAUSES AN
UNEVENNESS IN SLAB, THE CONTRACTOR SHALL PATCH/REPAIR/PREP THE SLAB FOR A SMOOTH LEVEL FLOOR
TO RECEIVE NEW FLOOR FINISHES.
14.CONTRACTOR SHALL DEMO AND REMOVE ALL ABANDONED CABLING IN THE CEILING TO THE POINT OF
ORIGIN AS REQUIRED BY LOCAL GOVERNING ELECTRICAL CODES, INCLUDING BUT NOT LIMITED TO THE
FOLLOWING; PHONE CABLE, COAXIAL CABLE, TV CABLE, LOW VOLTAGE CABLE, AND CONTROL WIRING NOT
BEING UTILIZED.
15.CONTRACTOR SHALL INSTALL FILTERS IN THE MAIN RETURN HVAC TRUNK WHILE IN CONSTRUCTION.
16.CONTRACTOR SHALL PATCH AND/OR REPAIR ALL EXISTING WALLS, COLUMNS, SILLS, ETC. WHICH ARE
DAMAGED OR EFFECTED BY DEMOLITION. EXISTING PARTITIONS SHALL BE EQUAL TO NEW.
REFLECTED CEILING DEMOLITION NOTES
17.REFER TO SHEET ID0.1 FOR GENERAL DEMOLITION NOTES AND ID0.2 FOR GENERAL REFLECTED CEILING
NOTES. REFER TO SHEET ID1.0 FOR (FLOOR) DEMOLITION PLAN.
18.REFER TO REFLECTED CEILING PLAN FOR EXTENT OF CEILING DEMOLITION.
19.REFER TO ENGINEER'S DRAWINGS FOR ADDITIONAL DEMOLITION SCOPE.
20.ALL DEMOLISHED CEILING FIXTURES (LIGHTS, EXIT SIGNS, ETC) ARE TO BE SAVED AND STORED FOR POSSIBLE
RE-USE.
21.ALL DEMOLISHED CEILING GRID AND TILES ARE TO BE SAVED, AND STORED FOR POSSIBLE RE-USE.
22.CONTRACTOR SHALL DEMO AND REMOVE ALL ABANDONED CABLING IN THE CEILING TO THE POINT OF
ORIGIN AS REQUIRED BY CITY OF LOS ANGELES ELECTRICAL CODES, INCLUDING BUT NOT LIMITED TO THE
FOLLOWING; PHONE CABLE, COAXIAL CABLE, TV CABLE, LOW VOLTAGE CABLE, AND CONTROL WIRING NOT
BEING UTILIZED.
23.CONTRACTOR SHALL INSTALL FILTERS IN THE MAIN RETURN HVAC TRUNK WHILE IN CONSTRUCTION.
24.CONTRACTOR SHALL PATCH AND/OR REPAIR ALL EXISTING WALLS, COLUMNS, SILLS, ETC. WHICH ARE
DAMAGED OR EFFECTED BY DEMOLITION. EXISTING PARTITIONS SHALL BE EQUAL TO NEW.
SYMBOL DESCRIPTION SYMBOL DESCRIPTION
SCALE :
NORTH
DEMOLITION PLAN
1/8" = 1'-0"
ID1.0
DEMOLITION PLAN AND
REFLECTED CEILING
DEMOLITION PLAN
EXISTING PARTITION TO REMAIN
EXISTING PARTITION TO BE REMOVED
SHADED AREA INDICATES PORTION OF BUILDING NOT INCLUDED IN SCOPE OF WORK
(NIC)
EXISTING DOOR TO BE REMOVED
DENOTES EXISTING TO BE REMOVED(D)
DENOTES EXISTING TO BE ABANDONED(A)
DENOTES EXISTING TO REMAIN(E)
EXISTING DOOR TO REMAIN
EXISTING GYPSUM BOARD CEILING TO REMAIN
EXISTING ACOUSTICAL CEILING TILE SYSTEM TO REMAIN
EXISTING ACOUSTICAL CEILING TILE SYSTEM TO BE REMOVED
EXISTING GYPSUM BOARD CEILING TO BE REMOVED
DENOTES EXISTING TO BE REMOVED(D)
DENOTES EXISTING TO BE ABANDONED(A)
DENOTES EXISTING TO REMAIN(E)
DENOTES EXISTING TO BE RELOCATED(R)
SCALE :
NORTH
REFLECTED CEILING DEMOLITION PLAN
1/8" = 1'-0"
DN
UP
DN
UP
UP
(E) WOMENS
RESTROOM
104OFFICE
111
OFFICE
110
(E) MENS
RESTROOM
103
(E) OPEN
OFFICE
106
(E)
EXIT CORRIDOR
-
CAFE
101
BOH
102
LOBBY
100
STORAGE
105
DN
UP
DN
UP
UP
(E) WOMENS
RESTROOM
104OFFICE
111
OFFICE
110
(E) MENS
RESTROOM
103
(E) OPEN
OFFICE
106
(E)
EXIT CORRIDOR
-
CAFE
101
BOH
102
LOBBY
100
STORAGE
105
(E)
(E)
(E)
(E)
(E)
(E)
DN
UP
DN
UP
UP
(E) WOMENS
RESTROOM
104OFFICE
111
OFFICE
110
(E) MENS
RESTROOM
103
(E) OPEN
OFFICE
106
(E)
EXIT CORRIDOR
-
OPEN TO
ABOVE
(E)
(E)
F1
F1
F2F2
F1 F1
F3F4
F3
F3
10
13
ID5.2 TYP.
6'-6"3'-4"
4'
-
1
"
4'
-
4
"
3'-4"
2'-6"
3'
-
2
"
2'-0"
6'-3"
3'-
0
"
1'
-
6
"
2'-0"
4'-10"
1'
-
6
"
2'-
1
"
4'-
2
"
1'-6"
7'-6"
11
11
11
11
12
12
12
1313
13
13
1
1
DN
UP
DN
UP
UP
(E) WOMENS
RESTROOM
104OFFICE
111
OFFICE
110
(E) MENS
RESTROOM
103
(E) OPEN
OFFICE
106
(E)
EXIT CORRIDOR
-
CAFE
101
BOH
102
LOBBY
100
STORAGE
105
DN
UP
DN
UP
UP
(E) WOMENS
RESTROOM
104OFFICE
111
OFFICE
110
(E) MENS
RESTROOM
103
(E) OPEN
OFFICE
106
(E)
EXIT CORRIDOR
-
CAFE
101
BOH
102
LOBBY
100
STORAGE
105
DN
UP
DN
UP
UP
(E) WOMENS
RESTROOM
104OFFICE
111
OFFICE
110
(E) MENS
RESTROOM
103
(E) OPEN
OFFICE
106
(E)
EXIT CORRIDOR
-
7'-2"
14
'
-
1
"
3'-0"
80°
3'
-
0
"
7'
-
4
"
4'-0"100
°
11
'
-
1
1
"
3'-
4
"
21
'
-
5
"
3'
-
0
"
±2
5
'
-
0
"
1'-6"
4'-8"
4'-0"
6'
-
7
"
6'-8"
12
'
-
1
"
R3'-
0
"
5'
-
0
"
M
I
N
.
-
ID4.0
-
ID4.0
3C
ID4.0
3A
ID4.0
-
ID4.0
C1
C1
C1
C2 C2
C1
C1
S
I
M
.
1
ID4.0
2A
ID4.0
2B
ID4.0
3C
ID4.0
3B
ID4.0
5'
-
9
"
2'-8"
1'
-
1
"
P
2'
-
4
"
1'-6"
2'-2"
2'-6"
2'-
1
1
"
C3
C3
2'-7"
2'
-
7
"
4
ID4.0
C
D
A
B
-
4
ID4.0
A
D
C
B
SIM.
1
1
Sheet Title:
ISSUE DATE
ISSUE FOR PLANCHECK 12.22.2025
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ENGINEER/CONSULTANT
ARCHITECT/ENGINEER STAMP
30
5
W
4
T
H
S
T
R
E
E
T
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
1
CA
F
E
OA
S
I
S
CLIENT
www.madstudiola.com
CITY STAMP
Project Director:
Project Designer:
Project Tech:
Project No:25030.300E.M.
E.M.
S.P.
ISSUED FOR MEP 01.13.2026
ISSUED FOR PLAN CHECK COMMENTS- PLANNING DEPT.01.22.2026
ISSUED FOR PRICING 02.17.2026
ISSUED FOR PLAN CHECK COMMENTS - PLANNING DEPT.02.20.2026
ISSUED FOR COUNTY REVIEW 03.24.2026
ISSUED FOR ADDENDUM A 03.27.2026
ISSUED FOR BUILDING DEPT REVIEW 04.08.2026
ISSUED FOR BUILDING DEPT REVIEW - RESUBMITTAL 05.05.2026
ISSUED FOR BUILDING DEPT CORRECTIONS 05.20.2026
SHEET NOTES LEGEND
SYMBOL DESCRIPTION DETAIL SYMBOL DESCRIPTION DETAIL 1.REFER TO SHEET ID0.1 FOR GENERAL PARTITION NOTES.
2.ALL NEW PARTITIONS SHALL BE TYPE "B1", U.O.N.
3.ALL WORK SHALL BE CONSTRUCTED TO FULLY COMPLY WITH LOCAL BUILDING CODES, INCLUDING
BUILDING AND SAFETY, FIRE/LIFE SAFETY AND ADA REQUIREMENTS.
4.REFER TO DETAIL 1/ID5.1 FOR TYPICAL CORNER AND JOINT DETAILS AT DRYWALL PARTITIONS
5.REFER TO SHEETS ID3.0 FOR DOOR, HARDWARE SCHEDULE, FIXTURE SCHEDULE, AND EQUIPMENT SCHEDULE.
6.PROVIDE SUPPORT BACKING AT ALL NEW AND EXISTING PARTITIONS THAT ARE TO RECEIVE NEW MILLWORK,
WALL-MOUNTED TELEVISIONS, MONITORS AND/OR MARKER BOARDS, U.O.N. ON PLAN. REFER TO DETAIL
3/ID6.0 FOR TYPICAL BRACING DETAIL.
7.ALL DIMENSIONS ARE FROM FACE OF FINISH TO FACE OF FINISH, U.O.N.
8.THE GENERAL CONTRACTOR SHALL VERIFY ALL ALIGNMENTS IN THE FIELD. IF MISALIGNMENT OF EXISTING
ELEMENTS SHOULD OCCUR, THE GENERAL CONTRACTOR SHALL VERIFY THE OPTION OF FURRING
PARTITION(S) AS NECESSARY TO PROVIDE THE REQUIRED ALIGNMENT.
9.WHERE ALIGNMENTS BETWEEN TWO ELEMENTS ARE CRITICAL, TOLERANCE FOR SUCH ALIGNMENT SHALL
NOT EXCEED 14" IN 10'-0".
10.REPAIR/PREP ALL EXISTING PARTITIONS, DOORS FRAMES, ETC SCHEDULED TO RECEIVE A NEW FINISH.
11.LEVEL OR "FLOAT" EXISTING FLOOR SLAB WHERE REQUIRED FOR LEVEL FINISH AND APPEARANCE.
12.GENERAL CONTRACTOR TO VERIFY EXISTING WALL BASE HEIGHT AND SKIM WALL AS REQUIRED TO RECEIVE
NEW WALL BASE.
13.PROVIDE TACTILE EXIT SIGNS AS REQUIRED BY THE INSPECTOR.
14.DOOR OPENINGS IN GYPSUM BOARD PARTITIONS NOT DIMENSIONED ARE TO BE LOCATED IN CENTER OF
ROOM OR 4" FROM ADJOINING PARTITION, U.O.N.
15.UNLESS OTHERWISE NOTED, CONTRACTOR SHALL PROVIDE 1/4" COPPER LINE AND ISOLATION VALVES AT ALL
SINK LOCATIONS FOR COFFEE MAKERS AND REFRIGERATORS. MOUNT BELOW COUNTERTOP.
16.FIRE EXTINGUISHER CABINETS (FEC) SHALL BE BUILDING STANDARD OR APPROVED EQUAL, U.O.N. (TYPICAL 6"
STUD DEPTH, TO BE VERIFIED).
17.LEVEL OR FLOAT FLOORS WHERE REQUIRED FOR LEVEL FINISH AND APPEARANCE, WHERE FURNITURE/MILLED
UNITS AND ARCHITECTURAL ELEMENT ALIGNMENTS ARE CRITICAL (I.E. @ SLIDING DOORS, FILE ENCLOSURES,
BASES AT FULL HEIGHT CLOSETS, ETC.) TOLERANCE TO BE NO MORE THAN 1/4" IN 10'-0".
REFLECTED CEILING NOTES
18.ALL CEILINGS SHALL BE +9'-0" A.F.F.
19.REFER TO SHEET ID0.2 FOR GENERAL REFLECTED CEILING PLAN NOTES. REFER TO SHEET ID0.4 FOR GREEN
BUILDING NOTES.
20.ALL NEW SCHEDULED CEILING TYPE (E.G. A.C.T, GYP. BD.) TO BE INSTALLED AT +8'-9" TO MATCH EXISTING
CEILING HEIGHTS, U.O.N.; VERIFY EXISTING CEILING HEIGHTS AND NOTIFY ARCHITECT OF ANY
DISCREPANCIES PRIOR TO INSTALLATION.
21.THE GENERAL CONTRACTOR SHALL OBTAIN EXACT LOCATIONS OF LIGHT FIXTURES AT OPEN OR HARD
CEILING FROM MAD STUDIO AND/OR LIGHTING CONSULTANT PRIOR TO INSTALLATION.
22.ALL LIGHT FIXTURES SHOWN ON PLAN ARE NEW, U.O.N. "(E)" INDICATES EXISTING FIXTURES TO REMAIN. "(R)"
INDICATES EXISTING FIXTURES TO BE REINSTALLED AT THE LOCATION SHOWN ON PLAN(S).
23.REFER TO ELECTRICAL ENGINEERING DRAWINGS FOR LIGHT SWITCH LOCATIONS, U.O.N.
24.ALL LIGHT SWITCHES, PROJECTION SCREEN CONTROLS, AND THERMOSTATS SHALL BE GANGED TOGETHER
WHERE POSSIBLE. REFER TO ENGINEERS DRAWINGS FOR LOCATION ON PLAN. REFER TO "OUTLET LOCATION
HEIGHTS" SECTION ON SHEET ID3.0 FOR HEIGHT LOCATIONS.
25.ALL CEILING SYSTEMS AND FIXTURES ARE TO BE SUPPORTED AND BRACED AS REQUIRED BY LOCAL
GOVERNING CODES.
26.AT CONDITIONS OF INTERFERENCE BETWEEN DUCTWORK AND LIGHT FIXTURE, PROVIDE NECESSARY
MEASURES TO ACCOMMODATE FIXTURE.
27.EXTEND OR MODIFY FIRE/LIFE SAFETY SYSTEM AS REQUIRED.
28.WHERE LIGHT FIXTURES, SPRINKLER HEADS, FIRE/LIFE SAFETY DEVICES, ETC. THAT ARE TO BE INSTALLED IN AN
ACOUSTICAL TILE CEILING, SUCH FIXTURES ARE TO BE INSTALLED IN THE CENTER OF THE CEILING TILE, U.O.N.
29.ALL CEILING FIXTURES SHALL BE CENTERED IN CEILING TILES (EQUALLY IN BOTH DIRECTIONS), U.O.N. IF TWO
OR MORE SPRINKLER HEADS OCCUR IN ONE ROOM, THEY SHALL BE ALIGNED WITH EACH OTHER. PROVIDE
SEMI-RECESSED CHROME HEADS WITH WHITE ESCUTCHEONS AT SUSPENDED TILE CEILINGS AND
CONCEALED TYPE HEADS AT DRYWALL CEILINGS, COLOR TO MATCH CEILING COLOR FINISH.
30.ALL EXPOSED DATA/PHONE LINES SHALL BE IN CABLE TRAYS OR SHALL BE IN RIGID CONDUIT WHEN
CROSSING OPEN CEILING AREAS.
31.PROVIDE ACCESS PANELS WHERE REQUIRED, SPEC: WIND-LOCK STEALTH GFRG. VERIFY LOCATION AND SIZE
WITH MAD PRIOR TO INSTALLATION.
32.PROVIDE LINEAR DIFFUSERS IN DRYWALL CEILINGS WHERE SUPPLY/RETURN AIR IS REQUIRED, U.O.N. REFER TO
MECHANICAL ENGINEERING DRAWINGS FOR HVAC REQUIREMENTS. VERIFY FINAL LOCATION OF DIFFUSERS
WITH MAD PRIOR TO INSTALLATION.
33.RE-USE EXISTING WINDOW TREATMENTS, CLEAN/FIX AS REQUIRED OR PROVIDE NEW WINDOW TREATMENTS
TO MATCH BUILDING STANDARD THROUGHOUT, U.O.N. MOUNT WINDOW TREATMENTS TO WINDOW
USING ONLY METHODS APPROVED BY THE BUILDING OWNER/LANDLORD.
34.PROVIDE ADDITIONAL EXIT SIGNS AS REQUIRED BY THE FIRE INSPECTOR.
35.ALL (E) CEILING AND ASSOCIATED CEILING DEVICES ARE TO REMAIN, U.O.N.
ADDITIONAL NOTES:
THE LIGHTING PACKAGE AS OUTLINED IN THE (RCP) LEGEND IS PROPRIETARY AND HAS BEEN APPROVED BY THE
OWNER/CLIENT FOR THE DESIGN INTENT FOR THIS PROJECT.
PRIOR TO FINAL BID SUBMITTAL, THE GENERAL CONTRACTOR SHALL VERIFY THIS LIGHTING PACKAGE CONFORMS
TO THE PROPOSED PROJECT SCHEDULE. IF THERE ARE ANY SCHEDULE CONFLICTS, THE GENERAL CONTRACTOR
SHALL PROMPTLY NOTIFY THE CLIENT/DESIGNER. SUB-CONTRACTOR TO PROVIDE UNIT PRICING PER FIXTURE; ANY
BIDS NOT CONTAINING UNIT PRICING WILL BE ELIMINATED.
AFTER AWARD OF CONTRACT, ANY CHANGE ORDERS DUE TO MODIFICATIONS TO THIS LIGHTING PACKAGE
WILL NOT BE ACCEPTED. MOREOVER, THE GENERAL CONTRACTOR, SUBCONTRACTORS, AND ANY OTHER
CONTRACTOR INVOLVED IN THIS PROJECT SHALL TAKE NOTE THAT ANY COSTS DUE TO REMEDIAL WORK AS A
RESULT OF, BUT NOT LIMITED TO, DEVIATION FROM THE LIGHTING PACKAGE, INFERIOR WORKMANSHIP OR
MATERIALS, AND/OR IMPROPER SCHEDULING OR DELINQUENT ORDERING, SHALL BE BORNE BY THE RESPONSIBLE
PARTY.
KEYNOTES
SCALE :
NORTH
REFLECTED CEILING PLAN
1/8" = 1'-0"
SHADED AREA INDICATES PORTION OF BUILDING NOT
INCLUDED IN SCOPE OF WORK (NIC)
FLOOR-TO-STRUCTURE ABOVE PARTITION (NON-RATED)
MILLWORK
BLDG STD FIRE EXTINGUISHER CABINET. SEE DETAIL 5/ID5.1
EXISTING PARTITION TO REMAIN
REFER TO SHEET ID4.0
REFER TO DETAIL 5/ID5.1
EXISTING DOOR TO REMAIN
NEW OR RELOCATED DOOR AS SCHEDULED#REFER TO ID3.0
FE
FEC
BLDG STD FIRE EXTINGUISHER
C1
C2 REFER TO DETAIL
3/ID5.0
REFER TO DETAIL
1/ID5.0
ID2.0
PARTITION PLAN AND
REFLECTED CEILING PLAN
SCALE :
NORTH
PARTITION PLAN
1/8" = 1'-0"
EXISTING GYPSUM BOARD CEILING TO REMAIN
NEW GYPSUM BOARD CEILING. REFER TO SHEET id5.2
A1
PARTITION TYPE DESIGNATION (I.E. 1-HOUR RATED, FULL-HEIGHT, LOW-HEIGHT, ETC.)
MODIFIER. REFER TO PARTITION DETAIL FOR DETAILED INFORMATION REGARDING STUD
GAUGE, SIZE & FRAMING AND ANY ADDITIONAL COMMENTS RELATED TO THE
CONSTRUCTION OF PARTITION TYPE
FLOOR-TO-STRUCTURE ABOVE PARTITION (NON-RATED)
10 SOFFIT TO ALIGN WITH MILLWORK BELOW
F1
F2 LED LIGHT TRACK LIGHT
SPECIFICATION: WAC LIGHTING PALOMA LED512:
WHK-LED512-F36°-35-870-_-BK
PENDANT CYLINDER LED LIGHT
SPECIFICATION: CAMMAN LIGHTING:
P4020-24-35K-50-CLV-MV-WM
F3
LED LIGHT TRACK LIGHT
SPECIFICATION: WAC LIGHTING PALOMA LED512:
WHK-LED512-F36°-35-870-_-BK
F4
LED LIGHT TRACK LIGHT
SPECIFICATION: WAC LIGHTING PALOMA LED512:
WHK-LED512-F36°-35-870-_-BK
12" X 12" FLOOR SINK
FLOOR DRAIN
F1 REFER TO DETAIL
5/ID5.0PARTIAL HEIGHT FURRING PARTITION (NON-RATED)
11 EXISTING DRYWALL CEILING AND RECESSED LIGHTS TO REMAIN
12 ALL EXISTING DUCT WORK/HVAC EQUIPMENT ABOVE EXISTING DRYWALL CEILING TO REMAIN
ENCLOSED.
13 TRACK LIGHTS FIXTURES AT SOFFIT AND DRYWALL CEILINGS SHALL BE MOUNTED FLUSH TO THE CEILING
A
A
1 AUTOMATIC DOOR ACTUATOR
DN
UP
DN
UP
UP
(E) WOMENS
RESTROOM
104OFFICE
111
OFFICE
110
(E) MENS
RESTROOM
103
(E) OPEN
OFFICE
106
(E)
EXIT CORRIDOR
-
10
3
CAFE
101
BOH
102
LOBBY
100
105
STORAGE
105
DN
UP
DN
UP
UP
(E) WOMENS
RESTROOM
104OFFICE
111
OFFICE
110
(E) MENS
RESTROOM
103
(E) OPEN
OFFICE
106
(E)
EXIT CORRIDOR
-
10
3
CAFE
101
BOH
102
LOBBY
100
105
STORAGE
105
4'-
0
"
AC
C
E
S
S
I
B
L
E
C
O
U
N
T
E
R
5'-2"
ACCESSIBLE COUNTER
ADA
ADA
DN
UP
DN
UP
UP
(E) WOMENS
RESTROOM
104OFFICE
111
OFFICE
110
(E) MENS
RESTROOM
103
(E) OPEN
OFFICE
106
(E)
EXIT CORRIDOR
-
10
3
CAFE
101
BOH
102
LOBBY
100
105
STORAGE
105
DN
UP
DN
UP
UP
(E) WOMENS
RESTROOM
104OFFICE
111
OFFICE
110
(E) MENS
RESTROOM
103
(E) OPEN
OFFICE
106
(E)
EXIT CORRIDOR
-
10
3
CAFE
101
BOH
102
LOBBY
100
105
STORAGE
105
+42
+42
+42
+42
+42
+42
+42
+72
4'-
0
"
AC
C
E
S
S
I
B
L
E
C
O
U
N
T
E
R
5'-2"
ACCESSIBLE COUNTER
ADA
ADA
Sheet Title:
ISSUE DATE
ISSUE FOR PLANCHECK 12.22.2025
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ENGINEER/CONSULTANT
ARCHITECT/ENGINEER STAMP
30
5
W
4
T
H
S
T
R
E
E
T
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
1
CA
F
E
OA
S
I
S
CLIENT
www.madstudiola.com
CITY STAMP
Project Director:
Project Designer:
Project Tech:
Project No:25030.300E.M.
E.M.
S.P.
ISSUED FOR MEP 01.13.2026
ISSUED FOR PLAN CHECK COMMENTS- PLANNING DEPT.01.22.2026
ISSUED FOR PRICING 02.17.2026
ISSUED FOR PLAN CHECK COMMENTS - PLANNING DEPT.02.20.2026
ISSUED FOR COUNTY REVIEW 03.24.2026
ISSUED FOR ADDENDUM A 03.27.2026
ISSUED FOR BUILDING DEPT REVIEW 04.08.2026
ISSUED FOR BUILDING DEPT REVIEW - RESUBMITTAL 05.05.2026
ISSUED FOR BUILDING DEPT CORRECTIONS 05.20.2026
SHEET NOTES
SYMBOL DESCRIPTION
KEYNOTES LEGEND
SYMBOL DESCRIPTION1.REFER TO SHEET ID0.1 FOR GENERAL POWER & DATA NOTES.
2.REFER TO SHEET ID3.0 FOR EQUIPMENT SCHEDULE. REFER TO ELECTRICAL ENGINEER DRAWINGS FOR
ADDITIONAL EQUIPMENT/DEVICE REQUIREMENTS.
3.REFER TO 3/ID5.1 FOR TYPICAL OUTLET INSTALLATION DETAIL.
4.ALL POWER AND DATA RECEPTACLES SHALL BE LOCATED AT THE CENTER OF WALLS OR COLUMNS IN WHICH
THEY OCCUR, U.O.N. IN PLANS AND DETAILS. THE MAXIMUM SEPARATION BETWEEN SIDE-BY-SIDE OUTLETS
SHALL BE 6" O.C, U.O.N.
5.ELECTRICAL, PHONE/DATA, & AV OUTLETS TO BE INSTALLED AT 18" AFF, U.O.N. REFER TO "OUTLET LOCATION
HEIGHTS" ON SHEET ID3.0 FOR ADDITIONAL REFERENCED OUTLETS.
6.CONTRACTOR SHALL CONFIRM ALL OUTLETS SHOWN BACK-TO-BACK IN PARTITION SHALL BE OFFSET THE
MINIMUM DIMENSION REQUIRED (WITHOUT TOUCHING) TO AVOID BACK-TO-BACK INSTALLATION.
7.PROVIDE THERMOSTATS AS REQUIRED PER ENGINEERING DRAWINGS. MAD TO APPROVE ALL LOCATIONS.
REFER TO "OUTLET LOCATION HEIGHTS" ON SHEET ID3.0 FOR ADDITIONAL REFERENCED OUTLETS.
8.PROVIDE NEW COVERPLATES THROUGHOUT, TO MATCH WALL COLOR FINISH; SPEC: LUTRON COLOR
SWATCH OR APPROVED EQUAL. PROVIDE BLACK COVERPLATES AT WOOD PANELING, DARK TILE, OR
DARK/BLACK FINISH WALLS.
9.GANG ALL SWITCHES UNDER ONE COVER PLATE WHERE POSSIBLE.
10.ALL POWER & DATA OUTLETS SHOWN ON PLAN ARE NEW TO MATCH BUILDING STANDARD, U.O.N. "(E)"
INDICATES EXISTING OUTLETS TO REMAIN.
11.PROVIDE SINKTOP SWITCH AT COUNTER FOR GARBAGE DISPOSAL, U.O.N.
12.THE GC SHALL COORDINATE LOCATION OF OUTLETS ON WALLS w/ MILLWORK & EQUIPMENT. VERIFY FINAL
LOCATION w/ MAD PRIOR TO INSTALLATION.
13.ALL OUTLETS MOUNTED ABOVE COUNTER TOPS TO BE HORIZONTAL. SEE PLAN FOR LOCATIONS.
14.ALL EXPOSED DATA/PHONE AND AV LINES SHALL BE IN CABLE TRAYS OR SHALL BE IN RIGID CONDUIT WHEN
CROSSING OPEN CEILING AREAS.
15.ALL CONDUIT, OTHER THAN THAT USED FOR ELECTRICAL OUTLETS AND LIGHT SWITCHES SHALL BE INSTALLED
TO COMPLY WITH RELEVANT CODES. JUNCTION BOXES SHALL RECEIVE PULL WIRE INSTALLED BY THE
CONTRACTOR.
16.THE CONTRACTOR SHALL VERIFY THE CONDUIT SIZE REQUIRED FOR ALL TELEPHONE/DATA, ELECTRICAL, AND
AV LINES WITH APPROPRIATE ENGINEERS PRIOR TO CORING TO OBTAIN PROPER CORE HOLE SIZES.
FURNITURE SHEET NOTES
17.FURNITURE ON PLANS IS SHOWN FOR REFERENCE ONLY (NIC).
18.ALL AISLES SERVING AS A PORTION OF AN EXIT ACCESS IN THE MEANS OF EGRESS SYSTEMS SHALL COMPLY
WITH THE REQUIREMENTS OF THE CURRENT CBC CHAPTER 10. THE MINIUM CLEAR WIDTH OF ALL AISLES IS
44", UON ON PLANS.
19.THE FURNITURE INSTALLER SHALL PROVIDE DIMENSIONED FURNITURE INSTALLATION PLANS FOR THE
DESIGNER'S APPROVAL PRIOR TO THE ORDERING AND INSTALLATION OF FURNITURE.
20.THE FURNITURE INSTALLER IS RESPONSIBLE FOR NOTIFYING MAD OF ANY DISCREPANCIES BETWEEN FIELD
CONDITIONS AND THE FURNITURE PLAN PRIOR TO INSTALLATION OF FURNITURE.FURNITURE DEALER TO
CONFIRM THAT ALL SPECIFIED FURNITURE IS LOCATED ON THE FURNITURE PLAN.
21.FURNITURE DEALER TO FIELD VERIFY DIMENSIONS OF ALL FURNITURE SPECIFIED AFTER MAD HAS APPROVED
DRYWALL PARTITION LAYOUT AT JOB SITE.
22.WHEN SPECIFICALLY CALLED FOR, FURNITURE DEALER SHALL PROVIDE DETAILED INVENTORY OF ALL EXISTING
FURNITURE TO INCLUDE MANUFACTURER, QUANTITY, SIZE, MODEL NUMBER AND FINISH.
23.FURNITURE DEALER SHALL PROVIDE FINISH OR FABRIC SAMPLES OF ALL SPECIFIED MATERIALS PRIOR TO
PLACEMENT OF ORDER.
24.FURNITURE DEALER SHALL VERIFY THAT ALL FURNITURE DELIVERED IS CORRECT PRIOR TO INSTALLATION.
25.WHERE TACK PANELS OCCUR ON DRYWALL PARTITIONS, DEALER SHALL LOCATE ALL ELECTRICAL OR
TELEPHONE OUTLETS PRIOR TO INSTALLATION, BASED ON DESIGNER'S PLAN OF OUTLET LOCATIONS.
DEALER TO ADVISE ON REQUIREMENTS FOR ALL REQUIRED ELECTRICAL OR TELEPHONE EXTENSION BOXES
WHICH OCCUR IN CONJUNCTION WITH APPLIED FABRIC WALL PANELS, IF PANELS ARE WITHIN DEALER
CONTRACT.
26.DEALER SHALL PROVIDE WEEKLY UPDATE ON STATUS OF ALL FURNITURE DELIVERIES AND OUTSTANDING
COSTS.
27.WHEN SPECIFICALLY CALLED FOR, DEALER AGREES TO PROVIDE, AT NO CHARGE TO THE CLIENT, RENTAL
FURNITURE OF ALL ITEMS NOT DELIVERED OR DELIVERED AS INCORRECT BY AGREED UPON INSTALLATION
DATE.
28.DESIGNER AND DEALER SHALL COORDINATE ORDER ENTRY DEADLINES AS PER MANUFACTURER REQUIRED
DELIVERY DATES.
29.DEALER, INSTALLATION FIRM, DESIGNER AND/OR ARCHITECT, AND CONTRACTOR SHALL COORDINATE TO
PROVIDE ALL REQUIRED PERMITS FROM THE LOCAL GOVERNING MUNICIPALITY AND TO COORDINATE WITH
THE CONTRACTOR'S PROJECT SCHEDULE TO INSURE THAT PERMITS ARE OBTAINED AND COINCIDE WITH
REQUIRED CODES AND/OR INSPECTIONS.
30.DEALER TO BE PROVIDED WITH FULL SET OF CONSTRUCTION DRAWINGS AND SHALL COORDINATE WITH
DESIGNER AND/OR ARCHITECT TO REVIEW POSSIBLE INSTALLATION PROBLEMS WHICH MIGHT OCCUR.
31.ALL DEALER PRICING TO INCLUDE TAX, FREIGHT, DELIVERY AND INSTALLATION. FOR THOSE COST ITEMS THAT
COULD NOT BE DETERMINED AT ORDER PLACEMENT, DEALER TO PROVIDE A "GOOD FAITH" ESTIMATE
OUTLINING ANY ADDITIONAL COSTS THAT THE CLIENT MAY INCUR.
32.DEALER TO REPAIR OR REPLACE ANY FURNITURE RECEIVED AS DAMAGED OR DAMAGED DUE TO
INSTALLATION. DEALER TO PROVIDE PRICING AND A SCHEDULE FOR THE ABOVE MENTIONED WORK.
33.DEALER TO BE RESPONSIBLE FOR COST AND OR REPAIR OF ANY DAMAGE TO CLIENT'S SPACE DUE TO
FURNITURE MOVE-IN.
34.DEALER AGREES TO BE RESPONSIBLE FOR ALL TIME AND/OR COSTS, INCURRED BY THE DESIGNER OR
ARCHITECT AS REQUIRED TO RE-SPECIFY, TRACK, OVERSEE INSTALLATION OF, PRODUCE A PUNCHLIST FOR,
OR TO RESOLVE ANY INCONVENIENCES TO THE CLIENT FOR ACTIONS NECESSARY DUE TO INCORRECT
FURNITURE DELIVERY, INCORRECT INSTALLATION, MISSING PIECES, LATE DELIVERIES, DISCONTINUED ITEMS,
OR ANY OTHER ISSUES WHICH MAY ARISE DUE TO CHANGES TO FURNITURE PURCHASE, DELIVERY AND
INSTALLATION WHICH DO NOT REFLECT THE AGREED UPON ISSUES AT THE TIME OF ORDER PLACEMENT.
SCALE :
NORTH
POWER & SIGNAL PLAN
1/8" = 1'-0"
ID2.1
POWER & SIGNAL PLAN
AND FURNITURE PLAN
(FOR REFERENCE ONLY)
SCALE :
NORTH
FURNITURE PLAN (FOR REFERENCE ONLY)
1/8" = 1'-0"
WALL-MOUNTED STANDARD DUPLEX OUTLET
WALL-MOUNTED DEDICATED DUPLEX OUTLET
WALL-MOUNTED STANDARD QUAD OUTLET
WALL MOUNTED ELECTRICAL JUNCTION BOX
WALL-MOUNTED G.F.C.I. DUPLEX OUTLET
J
FIXT. #J WALL MOUNTED ELECTRICAL JUNCTION BOX HARDWIRED TO FIXTURE. REFER TO LIGHT
FIXTURE SCHEDULE FOR TYPE AND MILLWORK ELEVATION FOR HEIGHT.
WALL-MOUNTED DOUBLE DUPLEX DATA OUTLET W/ 3/4" CONDUIT STUBBED TO CEILING
PLENUM
1-1/4" CONDUIT FOR AV CABLING - HOMERUN
1 -
10 BAR HIGH SEATS
8 TABLE SEATS (ADA) > 5% OF TOTAL SEATS
TOTAL CAFE SEATS 18
DN
UP
DN
UP
UP
(E) WOMENS
RESTROOM
104OFFICE
111
OFFICE
110
(E) MENS
RESTROOM
103
(E) OPEN
OFFICE
106
(E)
EXIT CORRIDOR
-
CAFE
101
BOH
102
LOBBY
100
STORAGE
105
FT1(E)
FT
1
FT
1
(E
)
QT
1
1
2
VF
1
VF1(E)
CB
1
2
1
DN
UP
DN
UP
UP
(E) WOMENS
RESTROOM
104OFFICE
111
OFFICE
110
(E) MENS
RESTROOM
103
(E) OPEN
OFFICE
106
(E)
EXIT CORRIDOR
-
CAFE
101
BOH
102
LOBBY
100
STORAGE
105
P-2
WT-1
CB-1
WT-1
CB-1
P-3
VF-1
WT-1
WT-1
Sheet Title:
ISSUE DATE
ISSUE FOR PLANCHECK 12.22.2025
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ENGINEER/CONSULTANT
ARCHITECT/ENGINEER STAMP
30
5
W
4
T
H
S
T
R
E
E
T
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
1
CA
F
E
OA
S
I
S
CLIENT
www.madstudiola.com
CITY STAMP
Project Director:
Project Designer:
Project Tech:
Project No:25030.300E.M.
E.M.
S.P.
ISSUED FOR MEP 01.13.2026
ISSUED FOR PLAN CHECK COMMENTS- PLANNING DEPT.01.22.2026
ISSUED FOR PRICING 02.17.2026
ISSUED FOR PLAN CHECK COMMENTS - PLANNING DEPT.02.20.2026
ISSUED FOR COUNTY REVIEW 03.24.2026
ISSUED FOR ADDENDUM A 03.27.2026
ISSUED FOR BUILDING DEPT REVIEW 04.08.2026
ISSUED FOR BUILDING DEPT REVIEW - RESUBMITTAL 05.05.2026
ISSUED FOR BUILDING DEPT CORRECTIONS 05.20.2026
KEYNOTESSHEET NOTES WALL, MILLWORK, AND FLOOR FINISHES SCHEDULE
MATERIALSYM MANUFACTURER STYLE COLOR NOTES MATERIALSYM MANUFACTURER STYLE COLOR NOTES1.REFER TO SHEET ID0.2 FOR GENERAL WALL FINISH NOTES.
2.ALL WALLS TO BE PAINTED P-1, U.O.N. ALL DRYWALL CEILINGS TO BE PAINTED P-1, U.O.N.
3.ALL WALLS/CEILINGS SHALL RECEIVE THE FOLLOWING, U.O.N.:
a.ONE (1) COAT OF PRIMER.
b.TWO (2) COATS OF PAINT FINISH AS SCHEDULED.
4.PROVIDE LEVEL 5 FINISH AT ALL DRYWALL SCHEDULED TO RECEIVE ACCENT PAINT.
5.PROVIDE B-1 WALL BASE, U.O.N.
6.PROVIDE 3/8" THK. x 2 1/2" H. PAINTED MDF WALL BASE OVER TILE, STONE FLOOR, EXPOSED CONCRETE,
AND/OR WOOD FLOORING, U.O.N.
7.NO BASE SHALL BE APPLIED TO CONCRETE WALLS, U.O.N.
8.REFER TO INTERIOR ELEVATIONS FOR MILLWORK FINISH DESIGNATIONS.
FLOOR FINISH NOTES
9.REFER TO SHEET ID0.2 FOR GENERAL FLOOR FINISH NOTES.
10.FOR WALL BASE REFER TO WALL FINISH PLAN AND SHEET NOTES.
11.THE GENERAL CONTRACTOR SHALL PATCH AND REPAIR THE EXISTING FLOOR AS REQUIRED.
12.ALL FINISHES ARE TO COMPLY WITH CLASS III FLAME-SPREAD REQUIREMENTS.
13.FLOOR FINISH SHALL BE CARPET C-1, U.O.N.
14.ALL FLOOR FINISHES TO BE INSTALLED PER MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS.
15.ALL CARPET TO BE INSTALLED USING THE MANUFACTURER'S RECOMMENDED NON-GLUE INSTALLATION.
SHOULD CARPET MANUFACTURER NOT HAVE A NON-GLUE INSTALLATION METHOD, CONTRACTOR SHALL
USE GRID-SET GREEN GLUE 2000 OR APPROVED SIMILAR. CONTRACTOR TO SUBMIT TECHNICAL DATA OF
GLUE PRIOR TO INSTALLATION.
16.ALL CARPET TO BE SEALED AS PER CARPET MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS.
17.PROVIDE BRUSHED STAINLESS STEEL TRANSITION STRIP AT CARPET TO EXPOSED CONCRETE FINISH, U.O.N.
18.ALL FLOORING TRANSITIONS SHOWN ARE EXISTING TO REMAIN, U.O.N. PROVIDE TRANSITION STRIP TO
MATCH EXISTING AT ALL NEW FLOOR TRANSITIONS, U.O.N.
19.GENERAL CONTRACTOR TO COORDINATE CARPET/VCT INSTALLATION AT ALL UNDER COUNTER AREAS.
20.FEATHER FLOORING AT ALL FINISH TRANSITIONS AS REQUIRED.
21.THE GENERAL CONTRACTOR SHALL PROVIDE SEAMING DIAGRAM FOR MAD'S APPROVAL PRIOR TO ORDERING
AND INSTALLING MATERIALS.
22.THE GENERAL CONTRACTOR SHALL PROVIDE THREE (3) SAMPLES EACH OF ALL FINISHED TO THE DESIGNER
FOR APPROVAL PRIOR TO INSTALLATION.
SCALE :
NORTH
FLOOR FINISH PLAN
1/8" = 1'-0"
ID2.2
WALL FINISH PLAN AND
FLOOR FINISH PLAN
SCALE :
NORTH
WALL FINISH PLAN
1/8" = 1'-0"
P-1 PAINT SHERWIN WILLIAMS 6441 WHITE EGGSHELL FINISH AT ALL WALLS.
PL-1 PLASTIC LAMINATE FORMICA 909 BLACK
FT
1 FLOOR TILE DALTILE QUARRY TILE ARID GRAY MATTE FINISH, 1/2" THICK
P-2 ART MURAL -CUSTOM CUSTOM -
SS-1 SOLID SURFACE CAESARSTONE 3100 JET BLACK
WT-1 WALL TILE DALTILE 0190 ARTIC WHITE 3 X 6 TILES
1 FLOOR TILE TO ALIGN WITH WALL TILE, REFER TO ELEVATIONS
1 FLOOR TILE TO ALIGN WITH WALL TILE, REFER TO ELEVATIONS
VF
1 VINYL FLOOR ARMSTRONG NATRAILS BIRCH SYRUP 4" MIN COVE BASE WITH 3/8" RADIUS
P-3 PAINT SHERWIN WILLIAMS 6441 WHITE SEMI GLOSS FINISH AT WALLS AND CEILINGS
CB
1 COVE BASE DALTILE QUARRY TILE ARID GRAY MATTE FINISH, ROUND TOP 1/2" THICK
5 X 6 TILES
C
1 CONCRETE ---EXISTING TO REMAIN
A
A
A
A
A
A
SYM MANUFACTURER
EQUIPMENT SCHEDULE
NOTESTYPEMODEL DESCRIPTION
SYM MANUFACTURER
FIXTURE SCHEDULE
NOTESTYPEMODEL DESCRIPTION
(ALL EQUIPMENT SHALL BE PROVIDED BY THE G.C. U.O.N.)
(ALL FIXTURES SHALL BE PROVIDED BY THE G.C. U.O.N.)
MANUFACTURER
DOOR HARDWARE GROUPS
QTY.MODEL DESCRIPTIONITEM FINISHGROUP
1A
LATCHSET
1 EA.LEVER LATCHSET SCHLAGE L- SERIES, LEVER TYPE -17, D - SPARTA SATIN STAINLESS STEEL
4 EA.BUTT HINGE HAGER B1279 4,5 x 4.5 STEEL W/ STEEL PINS ANSI A8112 SATIN
1 EA.DOOR STOP TRIMCO UNIVERSAL DOME STOP #1211 BLACK
1B
LATCHSET
1 EA.LEVER LATCHSET SCHLAGE L- SERIES, LEVER TYPE -17, D - SPARTA SATIN STAINLESS STEEL
4 EA.BUTT HINGE HAGER B1279 4,5 x 4.5 STEEL W/ STEEL PINS ANSI A8112 SATIN
1 EA.DOOR STOP TRIMCO UNIVERSAL DOME STOP #1211 BLACK
1 EA.CLOSER LCN 3130 - CONCEALED CLOSER ALUMINUM
1 EA.LEVER LOCKSET SCHLAGE L- SERIES, LEVER TYPE -17, D - SPARTA SATIN STAINLESS STEEL
4 EA.BUTT HINGE HAGER B1279 4,5 x 4.5 STEEL W/ STEEL PINS ANSI A8112 SATIN
1 EA.DOOR STOP TRIMCO UNIVERSAL DOME STOP #1211 BLACK
2B
LOCKSET
1 EA.LEVER LOCKSET SCHLAGE L- SERIES, LEVER TYPE -17, D - SPARTA SATIN STAINLESS STEEL
4 EA.BUTT HINGE HAGER B1279 4,5 x 4.5 STEEL W/ STEEL PINS ANSI A8112 SATIN
1 EA.DOOR STOP TRIMCO UNIVERSAL DOME STOP #1211 BLACK
1 EA.CLOSER LCN 3130 - CONCEALED CLOSER ALUMINUM
1 EA.LEVER LATCHSET SCHLAGE L- SERIES, LEVER TYPE -17, D - SPARTA SATIN STAINLESS STEEL
8 EA.BUTT HINGE HAGER B1279 4,5 x 4.5 STEEL W/ STEEL PINS ANSI A8112 SATIN
1 EA.DOOR STOP TRIMCO UNIVERSAL DOME STOP #1211 BLACK
1C
LATCHSET 1 EA.COORDINATOR IVES 900 SERIES
1 EA.ASTRAGAL PEMKO 355 S SATIN STAINLESS STEEL
1 EA.THRESHOLD
1 EA.AUTOMATIC FLUSH BOLTS TRIMCO #3810/3815
2A
LOCKSET
1 EA.LEVER LOCKSET SCHLAGE L- SERIES, LEVER TYPE -17, D - SPARTA SATIN STAINLESS STEEL
8 EA.BUTT HINGE HAGER B1279 4,5 x 4.5 STEEL W/ STEEL PINS ANSI A8112 SATIN
1 EA.DOOR STOP TRIMCO UNIVERSAL DOME STOP #1211 BLACK
1 EA.COORDINATOR IVES 900 SERIES
1 EA.ASTRAGAL PEMKO 355 S SATIN STAINLESS STEEL
1 EA.THRESHOLD
2C
LOCKSET
MILLWORK HARDWARE/ACCESORY SCHEDULE
SYM MANUFACTURER NOTESITEMMODEL DESCRIPTION
1 EA.AUTOMATIC FLUSH BOLTS TRIMCO #3810/3815
1 EA.CLOSER LCN 3130 - CONCEALED CLOSER ALUMINUM
1 EA.CLOSER LCN 3130 - CONCEALED CLOSER ALUMINUM
103 A 3'-0"8'-0"1 3/4"SCW STN ALU CLR 9A id5.1 9B id5.1 1A --
1 3 COMP SINK REGENCY 66" 16-GAUGE STAINLESS STEEL 3 COMPARTMENT COMMERCIAL SINK SINK WITH SS LEGS, CROSS BRACING, AND 2 DRAINBOARDS- 10" X 14" X 12" BOWLS
2 MOP SINK FAUCET ZURN Z843M1
3 MOP SERVICE BASIN ZURN ELKAY Z1996-24 24" X 24" X 10"
6 NOT USED ---
5 NOT USED ---
1 CABINET PULL
7 GROMMET DOUG MOCKETT MAX1/A-94 - "THE MAX" SMALL SIZE, 4 25/32" LONG, SATIN ALUMINUM
6 TRASH BIN CONTINENTAL 16 1/2" SQUARE SWINGLINE CAN, COLOR: GRAY
3 DRAWER GUIDE HAFELE ACCURIDE - 3832-22, FULL EXTENSION GUIDE, ZINC FINISH HEAVY DUTY
8 DOOR/DRAWER LOCK HAFELE CAM LOCKS, NATIONAL LOCK C8053-14A OWNER TO PROVIDE KEYING SCHEDULE AS REQUIRED
5 SHELF SUPPORTS HAFELE SELF SUPPORT, 1/4" DIA., ANGLE 282.11.761, NICKEL PLATED
WASTE: TRASH LOGO SATIN STAINLESS STEEL, REFER TO ELEV. FOR LOCATION RECYCLING:
RECYCLE LOGO SATIN STAINLESS STEEL, REFER TO ELEV. FOR LOCATION
DOOR TYPES
A
WIDTH
HE
I
G
H
T
DO
O
R
N
U
M
B
E
R
DO
O
R
W
I
D
T
H
DO
O
R
H
E
I
G
H
T
DO
O
R
T
H
I
C
K
N
E
S
S
DO
O
R
M
A
T
E
R
I
A
L
DO
O
R
F
I
N
I
S
H
FR
A
M
E
M
A
T
E
R
I
A
L
HA
R
D
W
A
R
E
G
R
O
U
P
FR
A
M
E
F
I
N
I
S
H
FI
R
E
R
A
T
I
N
G
DOOR FRAME
DO
O
R
T
Y
P
E
DOOR SCHEDULE
NOTES
ALU ALUMINUM
ANO ANODIZED
CLR CLEAR
(E)EXISTING
GL-1 CLEAR, TEMPERED GLASS (NON-RATED)
GL-2 20 MINUTE FIRE-RATED CLEAR, TEMPERED
GLASS - FIREGLASS, FIRELITE PLUS (OR
APPROVED EQUAL)
GLS TEMPERED GLASS (NON-RATED)
HM HOLLOW METAL
ABBREVIATIONS
MIN MINUTES
MC MINERAL CORE
N/A NOT APPLICABLE
NR NON-RATED
PT PAINT(ED)
PL PLASTIC LAMINATE
(R)RELOCATED
SCW SOLID CORE WOOD
STN STAINED FINISH
WF WOOD FRAME
DETAIL
HE
A
D
SI
L
L
JA
M
B
ENLARGED EQUIPMENT PLAN
5'
-
0
"
M
I
N
.
CL
E
A
R
A
N
C
E
1'-6"
MIN.
4'
-
0
"
M
I
N
.
CL
E
A
R
A
N
C
E
5'
-
0
"
M
I
N
.
CL
E
A
R
A
N
C
E
2'-0"
MIN.
1'-0"
MIN.
4'
-
0
"
M
I
N
.
CL
E
A
R
A
N
C
E
32"
MIN.CLR.
5'-0" MIN.
CLEARANCE
INTERIOR DOOREXTERIOR DOOR
DOORS IN SERIES
4'-0"MIN.
CLEARANCE
1'
-
6
"
MI
N
.
1'
-
0
"
MI
N
.
DOORS IN SERIES
4'-0" MIN.
CLEARANCE
1'
-
0
"
MI
N
.
1'
-
0
"
MI
N
.
DOOR CLEARANCES
OUTLET LOCATION HEIGHTS
FIRE
5'
-
0
"
6'
-
8
"
CENTERLINE DIMENSION OF SWITCHPLATES,
ELECTRICAL/DATA OUTLETS, SIGNAGE, OR FIRE
/MECHANICAL DEVICES
FIRE ALARM STROBE NEXT TO DOOR OPENING
ROOM SIGNAGE
THERMASTAT
LIGHT & PROJECTOR SCREEN SWITCHES, AND WALL
MOUNTED OCCUPANCY SENSORS
CARDREADER
LEVER TYPE DOOR HARDWARE
DATA OUTLET (INSTALL HORIZONTALLY WHEN OUTLET IS
INSTALLED OVER COUNTERTOP)
FINISHED FLOOR
NOTE:
LOCATE SWITCHPLATES, ELECTRICAL AND DATA WALL
OUTLETS AT NEAREST LOCATION ON PLAN, UNLESS
OTHERWISE NOTED ON PLAN, ELEVATION, OR LOCATION AS
PER DIAGRAM ABOVE.
CENTER FIRE ALARM STROBES DIRECTLY ABOVE FIRE
EXTINGUISHER CABINETS WHERE BOTH OCCUR.
S
CR
T
F
DEVICES SHOWN STACKED
IN PLAN ARE TO ALIGN
VERTICALLY AS SHOWN
ABOVE
6"
ELECTRICAL OUTLET (INSTALL HORIZONTALLY WHEN
OUTLET IS INSTALLED OVER COUNTERTOP)1'
-
6
"
(1
'
-
3
"
M
I
N
.
)
33
"
M
I
N
.
-
4
4
"
M
A
X
.
3'
-
6
"
(4
'
-
0
"
M
A
X
.
)
4'
-
0
"
M
A
X
.
DOOR & HARDWARE GENERAL NOTES
1.REFER TO SHEET ID0.3 FOR DOOR GENERAL ACCESSIBILITY NOTES.
2.THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON THE WORKING
DRAWINGS. THE CONTRACTOR SHALL NOTIFY MAD OF ANY DISCREPANCIES PRIOR TO COMMENCEMENT OF
ANY WORK. IN THE EVENT OF FAILURE TO DO SO, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
CORRECTION OF ANY ERROR.
3.PROVIDE HARDWARE AND ACCESSORIES AS REQUIRED FOR RATED AND MINERAL CORE DOORS.
4.ALL NEW DOORS SHALL RECEIVE LEVER HARDWARE (SEE HARDWARE SCHEDULE) UNLESS NOTED OTHERWISE.
HARDWARE SHALL BE IN COMPLIANCE WITH CBC TITLE 24 REQUIREMENTS.
5.ALL LABELED DOORS SHALL BE TIGHT-FITTING WITH A GASKET SO INSTALLED AS TO PROVIDE A SEAL WHERE
THE DOOR MEETS THE STOP ON BOTH SIDES AND ACROSS THE TOP.
6.GENERAL CONTRACTOR SHALL PROVIDE MANUFACTURERS' CERTIFICATION THAT GLAZING ON DOORS AND
WITHIN 4'-0" OF DOORS SHALL COMPLY WITH APPLICABLE CONSUMER PRODUCT SAFETY STANDARDS.
7.THE CONTRACTOR SHALL DEVELOP AND SUBMIT TO THE DESIGNER FOR APPROVAL FULL AND COMPLETE
SCHEDULE OF FINISH HARDWARE, INDICATING THE QUANTITY, PART NUMBER, INSTALLATION, LOCATION
AND FINISH OF EACH ITEM AS NEEDED FOR A COMPLETE AND PROPER INSTALLATION. BID PRICE SHALL BE
BASED ON THE HARDWARE SCHEDULE.
8.HARDWARE SCHEDULE SHALL INCLUDE BUT NOT NECESSARILY BE LIMITED TO: BUTTS, LOCKSETS, LATCHSETS,
CLOSERS, WEATHER-STRIPPING, PANIC HARDWARE, FLOOR HINGES, PIVOTS, KICK PLATES, PULLS, STOPS,
ANCHORS, WALL BUMPERS, THRESHOLDS, DOOR SHOES AND MUTES.
9.ALL DOORS TO HAVE INDIVIDUAL KEYS, STAMPED WITH ROOM NUMBER WITH ONE MASTER KEY. VERIFY
KEYING REQUIREMENTS AND QUANTITIES WITH OWNER. CONTRACTOR SHALL PROVIDE LOCK CYLINDERS,
KEYING AND KEYS.
10.CONTRACTOR TO PREP AND REWORK AND DRILL EXISTING DOORS, AS WELL AS NEW DOORS TO RECEIVE
SECURITY HARDWARE WHEN APPLICABLE.
11.THE MAXIMUM UNDERCUT OF ALL DOORS SHALL NOT EXCEED 1/2" (ONE-HALF INCH) ABOVE THE SURFACE
OF THE FINISHED FLOOR OR THRESHOLD. ALL DOORS SHALL BE UNDERCUT ON THE JOB SITE AND
SPECIFICALLY FOR INDIVIDUAL DOOR OPENINGS AND FLOOR FINISHES. THE CONTRACTOR SHALL VERIFY THE
FINISHED HEIGHT OF ALL FLOOR FINISHES PRIOR TO UNDERCUTTING OF DOORS.
12.HARDWARE SPECIFIED FOR INSTALLATION ON DOORS AND FRAMES WHICH REQUIRE A FIRE-RATED LABEL
SHALL COMPLY WITH ALL CODE REQUIREMENTS GOVERNING HARDWARE TYPE AND INSTALLATION METHODS
FOR RATED ASSEMBLIES.
13.INSTALL DOOR CLOSERS AS SPECIFIED ON ALL FIRE RATED DOORS.
14.ALL MORTISE STRIKES SHALL HAVE DUST COVERS.
15.ALL CORE BUILDING DOOR KEYWAYS SHALL BE APPROVED BUILDING STANDARD, UON.
1'-0"
1'-0"
MIN.
32"
MIN.CLR.
4 MILLWORK HINGE HAFELE 165° CONCEALED HINGE. PROVIDE 90° HINGE WHERE ADJACENT TO WALL
2 DOOR SYMBOL ARCH HARDWARE, INC.1/8" THK. x 2" SQUARE MEDALLION W/ ETCHED PATTERN
4 HAND WASH SINK REGENCY ONE COMPARTMENT DROP-IN SINK WITH 8" GOOSENECK FAUCET 20 GAUGE STAINLESS STEEL
A BACK FREEZER ATOSA MGF8405GR (E) TENANT PROVIDED
C COFFEE GRINDER MAHLKONIG EK43 (E) TENANT PROVIDED
D COFFEE PRESS PUQ PRESS 1-000-1420-2 (Q2/M2 FAMILY)(E) TENANT PROVIDED
E COFFEE SCALE ACAIA LUNAR SCALE ACA-AL012 Lithium-ion rechargeable 3.7 V 1100 mah
F DECAF COFFEE GRINDER MAZZER MINI ELECTRONIC (E) TENANT PROVIDED
G NOT USED ---
B TWIN COFFEE BREWER WILBUR CURTIS G4TP1T10A3100 (E) TENANT PROVIDED
I ESPRESSO GRINDER MAZZER KONY ELECTRONIC (E) TENANT PROVIDED
J ESPRESSO MACHINE LA MARZOCCO LINEA PB LN21 3AV (E) TENANT PROVIDED 208-240V, 30 A (2-grp); 50 A (3 grp)
K1 BACK FRIDGE TURBO AIR TWR-72SD-N (E) TENANT PROVIDED
K2 MILK FRIDGE BEVERAGE AIR UCR20HC-23 (E) TENANT PROVIDED
M GRAB AND GO TOM TOM-40LB-N (E) TENANT PROVIDED
N ICE MACHINE NOSHIZAKI KM-231-1BAJ (E) TENANT PROVIDED
O BLENDER VITAMIX -(E) TENANT PROVIDED
P REGISTER CLOVER POS
K3 SYRUP FRIDGE BEVERAGE AIR UCR20HC (E) TENANT PROVIDED
K4 REACH-IN REFRIGERATOR KUTANO KTR1SS (E) TENANT PROVIDED
7 ICE MAKER FILTER PENTAIR EVERPURE - IN LINE (E) TENANT PROVIDED
8 PITCHER RINSER RHINO WARE RHPR600-S
L HIGH SPEED OVEN MERRYCHEF EIKON E4 2-208V/240 60HZ
H BEVERAGE DISPENSER VOLLRATH VBBC4-37-A 115 V NEMA 5-15P
S LOCKERS SPG OR SIM KELMAX 4K0034 OR SIM W24" x D18" x H84"
R SHELVING TRINITY TBTPBA-0945B 6 TIER WIRE SHELVING 48 X 18 X 72
10
3
10
3
N
J
1
2
7
4
M
5
L
K3
K2
K4
P
B
A
K
E
K1
3
F
C
D
O
H
8
R
R
10
3
105
10
3
105
S
R
R
R
R
R
Sheet Title:
ISSUE DATE
ISSUE FOR PLANCHECK 12.22.2025
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ENGINEER/CONSULTANT
ARCHITECT/ENGINEER STAMP
30
5
W
4
T
H
S
T
R
E
E
T
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
1
CA
F
E
OA
S
I
S
CLIENT
www.madstudiola.com
CITY STAMP
Project Director:
Project Designer:
Project Tech:
Project No:25030.300E.M.
E.M.
S.P.
ISSUED FOR MEP 01.13.2026
ISSUED FOR PLAN CHECK COMMENTS- PLANNING DEPT.01.22.2026
ISSUED FOR PRICING 02.17.2026
ISSUED FOR PLAN CHECK COMMENTS - PLANNING DEPT.02.20.2026
ISSUED FOR COUNTY REVIEW 03.24.2026
ISSUED FOR ADDENDUM A 03.27.2026
ISSUED FOR BUILDING DEPT REVIEW 04.08.2026
ISSUED FOR BUILDING DEPT REVIEW - RESUBMITTAL 05.05.2026
ISSUED FOR BUILDING DEPT CORRECTIONS 05.20.2026
ID3.0
DOOR, HARDWARE &
EQUIPMENT SCHEDULE
A
A
1
2'
-
1
0
"
MA
X
.
5
ID6.0
SCALE
3/8" = 1'-0"MILLWORK ELEVATION - CAFE 101, 102
8'-4"CLR.5 EQ. SPACES
8'
-
6
"
1'
-
3
"
K1
2 EQ. SPACES
M
R
K4
2'
-
1
0
"
MA
X
.
9
ID6.0
3'-6"
1'
-
3
"
8'
-
6
"
9
ID6.0
3'-0"
11'-11"3'-4" CLR.
ABC
J
2'
-
2
"
1"1"1"1"
2'
-
2
"
NK2K3 A8
4'-3 1/2"
1"1"
2'-7"
1"1"
3'
-
0
1
/
2
"
4
7
ID6.0
S
L
SS-1PL-1
PL-1
PL-1 PL-1SS-1
SS-1
4'
-
0
"
4'
-
0
"
5'
-
0
"
5'
-
0
"
B10
ID6.0
WT-1
CB-1
WT-1
CB-1
3
2 R R
18"
SCALE
3/8" = 1'-0"MILLWORK ELEVATION - BREAK ROOM #
±25'-0"
2'
-
1
0
"
MA
X
.
8
ID6.0SS-1
2'
-
1
0
"
MA
X
.
9
ID6.0
SCALE
3/8" = 1'-0"MILLWORK ELEVATION - CAFE 100
AB
M
9'
-
9
"
1'
-
3
"
R
JJ
2'
-
2
"
2'
-
2
"
2'
-
1
0
"
8'
-
6
"
8'
-
6
"
1'
-
3
"
SS-1
SS-1
M
ART MURAL
ART MURAL
5'
-
0
"
5'
-
0
"
4"5"
6" EQUIPMENT
PLATFORM
10
ID6.0
2'
-
8
1
/
2
"
2
3
SCALE
3/8" = 1'-0"ELEVATIONS - EXISTING RESTROOMS
K-2035-8PINOIRLAVATORYVITREOUS CHINA
1'-0"
4'-0"
K-2035-8PINOIRLAVATORYVITREOUS CHINA
2'
-
1
0
"
1'
-
7
"
1'-6"
2'
-
1
0
"
1'
-
5
"
2'
-
1
0
"
D C B A
1'
-
5
"
2'
-
1
0
"
2'
-
2
1
/
2
"
1'-7 1/2"
6"
4'
-
0
"
3'-6"
2'
-
3
"
3
Sheet Title:
ISSUE DATE
ISSUE FOR PLANCHECK 12.22.2025
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ENGINEER/CONSULTANT
ARCHITECT/ENGINEER STAMP
30
5
W
4
T
H
S
T
R
E
E
T
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
1
CA
F
E
OA
S
I
S
CLIENT
www.madstudiola.com
CITY STAMP
Project Director:
Project Designer:
Project Tech:
Project No:25030.300E.M.
E.M.
S.P.
ISSUED FOR MEP 01.13.2026
ISSUED FOR PLAN CHECK COMMENTS- PLANNING DEPT.01.22.2026
ISSUED FOR PRICING 02.17.2026
ISSUED FOR PLAN CHECK COMMENTS - PLANNING DEPT.02.20.2026
ISSUED FOR COUNTY REVIEW 03.24.2026
ISSUED FOR ADDENDUM A 03.27.2026
ISSUED FOR BUILDING DEPT REVIEW 04.08.2026
ISSUED FOR BUILDING DEPT REVIEW - RESUBMITTAL 05.05.2026
ISSUED FOR BUILDING DEPT CORRECTIONS 05.20.2026
ID4.0
INTERIOR ELEVATIONS
A
A
A
A
A
A
A
A
A A A A
A
1
3
SCALE
3" = 1'-0"FLOOR-TO-STRUCT ABOVE PART. (NR)
TY
P
E
SIZE GA
STEEL STUD
SPAN NOTES/REMARKSINSUL
PARTITION TYPE "C1"
CONC SLAB
FLOOR FINISH AS
SCHEDULED
METAL STUD. REFER TO
CHART ABOVE FOR SIZE,
GAUGE, AND SPAN
CEILING AS SCHEDULED.
REFER TO REFLECTED
CEILING PLAN FOR
CEILING TYPE & HEIGHT
#10 SMS, ONE AT EA
SIDE OF STUD
600S162-54 @ 16" O.C.
CEILING JOISTS
FLOOR FINISH AS
SCHEDULED
CONC SLAB
CONTINUOUS
ACOUSTIC SEALANT
WALL BASE AS
SCHEDULED #10 SMS ONE AT EACH
SIDE OF STUD
CONT UNPUNCHED 20
GA FLOOR TRACK
ANCHORED TO SLAB
PROVIDE FRICTION-FIT
BATT INSULATION WHEN
INDICATED ABOVE
0.145"Ø x 1" EMBED POWDER
ACTUATED FASTENERS @ 32" O.C.
1 LAYER OF 5/8" THICK
TYPE "X" GYPSUM BOARD
AT EA SIDE OF STUD
GYPSUM BOARD NOTES:
1. ALL GYP BD SHEETS
ARE TO RUN VERTICALLY.
2. NO JOINTS EXCEPT AT
STUDS.
3. SEAL ALL
PENETRATIONS.
4. PROVIDE
WATER-RESISTANT GYP.
BD. AT WET AREAS.
5. ALL DUCTS
PENETRATING THIS
PARTITION SHALL
RECEIVE FIRE/SMOKE
DAMPERS.
8'
-
6
"
N
T
S
7/16" OSB PANEL
SHEATHING
C1 3-5/8"20 GA 16"R13
11
'
-
0
"
N
T
S
7/16"SHEATHING W/
#8 SCREWS @ 6" OC.
(ALL EDGES)
SCALE
3" = 1'-0"FLOOR-TO-STRUCT ABOVE PART. (NR)
TY
P
E
SIZE GA
STEEL STUD
SPAN NOTES/REMARKSINSUL
PARTITION TYPE "C2"
FLOOR FINISH AS
SCHEDULED
CONTINUOUS
ACOUSTICAL SEALANT
WALL BASE AS
SCHEDULED
C2 3-5/8"20 GA 16"R13
SCHEDULED CEILING
CONC SLAB
#10 SMS ONE AT
EA SIDE OF STUD
CONT UNPUNCHED 20 GA
FLOOR TRACK
ANCHORED TO SLAB
PROVIDE FRICTION-FIT
BATT INSULATION
WHEN INDICATED ABOVE
1 LAYER OF 5 8" THICK TYPE "X"
GYPSUM BOARD AT EACH
SIDE OF STUD
GYPSUM BOARD NOTES:
1.ALL GYP BD SHEETS ARE
TO RUN VERTICALLY.
2.NO JOINTS EXCEPT AT
STUDS.
3.SEAL ALL PENETRATIONS.
4.PROVIDE
WATER-RESISTANT GYP BD
AT WET AREAS.
REFER TO
RCP
11
'
-
0
"
PROVIDE ACOUSTICAL
SEAL, BOTH SIDES
600S162-54 @ 16" O.C.
CEILING JOISTS
7/16"SHEATHING W/
#8 SCREWS @ 6" OC.
(ALL EDGES)
7/16" OSB PANEL
SHEATHING
0.145"Ø x 1" EMBED POWDER
ACTUATED FASTENERS @ 32" O.C.
SCALE
3" = 1'-0"LOW-HEIGHT FURR PARTITION
FLOOR FINISH AS
SCHEDULED
FLOOR (E)
UL COMPLYING FASTENERS.
ONE AT EA SIDE OF EA
STUD
CONT UNPUNCHED 20 GA
FLOOR TRACK ANCHORED
TO SLAB
CONTINUOUS
ACCOUSTICAL SEALANT
(BOTH SIDES)
1 LAYER OF 5/8" THICK
TYPE "X" GYPSUM BOARD
AT FRONT SIDE OF STUD
GYPSUM BOARD NOTES:
1. ALL GYP BD SHEETS ARE
TO RUN VERTICALLY.
2. NO JOINTS EXCEPT AT
STUDS.
3. SEAL ALL
PENETRATIONS.
CONT. CORNER BEAD,
PAINTED TO MATCH WALL
METAL STUD FRAMING. REFER
TO CHART ABOVE FOR SIZE,
GAUGE AND SPAN
STEEL PLATE AT BASE OF
STRUCT. STEEL TUBE
STEEL STUDS: ICC-ESR-3064P
HILTI X-U SHOT PIN - 0.157
DIA X 1" EMBED @ 24" O.C.
(ICC ESR 2269)
TY
P
E
SIZE GA
STEEL STUD
SPAN NOTES/REMARKSINSUL
PARTITION TYPE "P"
F1 2-1/2"20 GA 24"R13
TOP OF MILLWORK PER
PLAN
EXISTING CONCRETE
PERIMETER WALL
5
Sheet Title:
ISSUE DATE
ISSUE FOR PLANCHECK 12.22.2025
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ENGINEER/CONSULTANT
ARCHITECT/ENGINEER STAMP
30
5
W
4
T
H
S
T
R
E
E
T
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
1
CA
F
E
OA
S
I
S
CLIENT
www.madstudiola.com
CITY STAMP
Project Director:
Project Designer:
Project Tech:
Project No:25030.300E.M.
E.M.
S.P.
ISSUED FOR MEP 01.13.2026
ISSUED FOR PLAN CHECK COMMENTS- PLANNING DEPT.01.22.2026
ISSUED FOR PRICING 02.17.2026
ISSUED FOR PLAN CHECK COMMENTS - PLANNING DEPT.02.20.2026
ISSUED FOR COUNTY REVIEW 03.24.2026
ISSUED FOR ADDENDUM A 03.27.2026
ISSUED FOR BUILDING DEPT REVIEW 04.08.2026
ISSUED FOR BUILDING DEPT REVIEW - RESUBMITTAL 05.05.2026
ISSUED FOR BUILDING DEPT CORRECTIONS 05.20.2026
ID5.0
CONSTRUCTION DETAILS
7 3
5
6
9 1
2
8
SCALE
N.T.S.TYPICAL CORNER/JOINT DETAIL
JOINT
END
CORNER
METAL CORNER BEAD W/ JOINT
COMPOUND & SAND SMOOTH
TAPE W/ JOINT COMPOUND & SAND SMOOTH
TAPE W/ JOINT COMPOUND & SAND SMOOTH
METAL CORNER BEAD W/ JOINT
COMPOUND & SAND SMOOTH
STAGGER JOINTS @ 24" MINIMUM
SCALE
3" = 1'-0"TYPICAL PARTITION INTERSECTION
PLAN C
PLAN A
PARTITION AS SCHEDULED
NOTE: GYPSUM BOARD IS NOT
CONTINUOUS. FILL INTERSECTION
CAVITY w/ ACOUSTICAL INSULATION
WHERE SCHEDULED
PLAN B
PLAN D
ACOUSTICAL
PARTITION AS
OCCURS
NOTE: GYPSUM
BOARD IS NOT
CONTINUOUS
SCALE
3" = 1'-0"OUTLET BOX @ PART w/ ACOUST INSUL
24" MIN
24" MIN
NOTE: SEPARATE CONDUIT
FOR OUTLET BOXES ON 2 SIDES
OF PARTITION. NO CONTACT
BETWEEN STUDS
NOTES:
1. PLACE OUTLET BOXES IN SEPARATE STUD SPACES
2. BACK-TO-BACK OUTLETS NOT PERMITTED
3. PLUG ALL UNUSED KNOCK-OUTS IN OUTLET BOXES WIT KNOCK-OUT CAPS
4. DEPTH OF OUTLET BOX MUST BE COMPATIBLE WITH STUD SIZE IN ORDER TO ACCOMMODATE BOX PAD
5. ACOUSTICAL BOX PAD REQUIREMENT APPLIES TO ALL PARTITIONS WITH ACOUSTICAL INSTALLATION
- APPLIES TO POWER, PHONE COMMUNICATIONS, ETC
TYPICAL DOUBLE STUD PARTITION WITH SOUND ISOLATION
(SIMILAR FOR STAGGERED STUDS)
TYPICAL SINGLE STUD PARTITION WITH SOUND ISOLATION
CONTINUOUS ACOUSTICAL
SEALANT AROUND ENTIRE
PERIMETER (TYP.)
TYPICAL OUTLET BOX
PARTITION AS SCHEDULED
BOX PAD
PARTITION AS SCHEDULED
SCALE
1-1/2" = 1'-0"FIRE EXTINGUISHER CAB (RATED/NR)
4'
-
0
"
A
F
F
T
O
T
O
P
O
F
C
A
B
I
N
E
T
,
U
.
O
.
N
.
ROUGH OPEN'G
VERIFY DIM.
W/ FEC SPEC
RO
U
G
H
O
P
E
N
I
N
G
VE
R
I
F
Y
W
/
S
P
E
C
I
F
I
C
A
T
I
O
N
RECESSED/ SEMI-RECESSED
FIRE EXTINGUISHER CABINET.
PROVIDE RATED CABINET AT
RATED WALLS
5/8" TYPE 'X' GYP BD AT
TOP, BOTTOM AND SIDES
OF RECESS
2 LAYERS OF 5/8" TYPE 'X'
GYP. BD.
PARTITION AS SCHEDULED.
PROVIDE 6" STUD AS
REQUIRED. REFER TO PLAN
SCALE
3" = 1'-0"ALUMINUM DOOR FRAME DETAIL
DOOR FRAME SILL B
A
DOOR FRAME JAMB C
PARTITION AS SCHEDULED
ALUMINUM DOOR FRAME
FRAME BEYOND
2"
VARIES
VERIFY PART. WIDTH
DOOR AS SCHEDULED
4"
PERPENDICULAR PARTITION
AS OCCURS
PARTITION AS SCHEDULED
ALUMINUM FRAME
DOOR HINGE, REFER TO
HARDWARE SCHEDULE
DOOR AS SCHEDULED
1
1
/
2
"
DO
O
R
O
P
E
N
'
G
RE
F
E
R
T
O
S
C
H
E
D
.
DOOR OPEN'G
REFER TO SCHED.
2"
2"
VA
R
I
E
S
VE
R
I
F
Y
P
A
R
T
.
W
I
D
T
H
1 1/2"
DOOR FRAME HEAD
2"
1/
2
"
MA
X
.
DOOR AS SCHEDULED
LINE OF FINISH FLOOR
LINE OF CONCRETE
FLOOR
17SCALE
6" = 1'-0"FLOOR TRANSITION TO CONC.DET.
CONCRETE FLOOR
FLOOR FINISH AS
SCHEDULED, FLOAT AS
REQUIRED
METAL REDUCER STRIP,
CONTRACTOR TO PROVIDE
SAMPLES FOR APPROVAL PRIOR TO
INSTALLATION
FULL DEPTH WOOD
BLOCKING
METAL STUDS, TYPICAL
CONT 16 GA (MODEL 54)
CEMCO CST/SLIP-TRK
SLOTTED (ICC-ESR-2012)
#10 SMS ONE AT
EA. SIDE OF STUD
SCREW TO PLATE W/
(2) #8 SMS
5/
8
"
M
A
X
.
DE
F
L
E
C
T
I
O
N
GA
P
SCALE
3" = 1'-0"METAL STUD ATTACHMENT
45°
45°
PERPENDICULAR
TO JOIST
PARRALLEL
TO JOIST
SCALE
NTSTYP. DIAGONAL BRACING DETAIL
EXISTING STRUCTURE ABOVE
212" X 20 GA METAL STUD
DIAGONAL BRACING AT 48"
OC MAX
ATTACH w/
#12 SMS
CEILING AS SCHEDULED.
REFER TO REFLECTED
CEILING PLAN
FULL DEPTH WOOD
BLOCKING. REFER TO
STRUCTURAL DWGS. FOR
ATTACHMENTS
~(E) WOOD JOIST BEYOND
(E) WOOD JOIST BEYOND
212" X 20 GA METAL STUD
DIAGONAL BRACING AT 48"
OC MAX
CEILING AS SCHEDULED.
REFER TO REFLECTED
CEILING PLAN
ATTACH w/
#12 SMS
EXISTING STRUCTURE ABOVE
FULL DEPTH WOOD
BLOCKING. REFER TO
STRUCTURAL DWGS. FOR
ATTACHMENTS
SCALE
3" = 1'-0"FLOOR / WALL QUARRY TILE DETAIL
6"
M
I
N
.
U
P
T
U
R
N
QUARRY WALL TILE AS
SCHEDULED O/ THINSET
OR MORTER BED
3 8" MAX. GROUT JOINT
QUARRY FLOOR TILE
(REFER TO FINISH FLOOR
PLAN)
WATERPROOF MEMBRANE
(MER-KRETE 300 OR
APPROVED EQUAL)
5/8" WATER RESISTANT
GYP.BD.
CEMENTITIOUS BACKER
BOARD
PARTITION AS SCHEDULED
EXISTING. FLOOR
A
B
C
LINE OF NEW CEILING
QUARRY COVE BASE -
FLOOR/WALL TRANSITION
RE
F
E
R
E
N
C
E
E
L
E
V
A
T
I
O
N
SCALE
3" = 1'-0"WALL TILE DETAIL
6"
M
I
N
.
U
P
T
U
R
N
WALL TILE AS SCHEDULED
O/ THINSET OR MORTER
BED
316" MAX. GROUT JOINT
FLOOR TILE
(REFER TO FINISH FLOOR
PLAN)
WATERPROOF MEMBRANE
(MER-KRETE 300 OR
APPROVED EQUAL)
5/8" WATER RESISTANT
GYP.BD.
CEMENTITIOUS BACKER
BOARD
PARTITION AS SCHEDULED
CONC. FLOOR
A
B
C
LINE OF NEW CEILING
3/8" SCHLUTERS®-DILEX-AHK
SS - FLOOR/WALL TRANSITION
RE
F
E
R
E
N
C
E
E
L
E
V
A
T
I
O
N
10
Sheet Title:
ISSUE DATE
ISSUE FOR PLANCHECK 12.22.2025
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ENGINEER/CONSULTANT
ARCHITECT/ENGINEER STAMP
30
5
W
4
T
H
S
T
R
E
E
T
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
1
CA
F
E
OA
S
I
S
CLIENT
www.madstudiola.com
CITY STAMP
Project Director:
Project Designer:
Project Tech:
Project No:25030.300E.M.
E.M.
S.P.
ISSUED FOR MEP 01.13.2026
ISSUED FOR PLAN CHECK COMMENTS- PLANNING DEPT.01.22.2026
ISSUED FOR PRICING 02.17.2026
ISSUED FOR PLAN CHECK COMMENTS - PLANNING DEPT.02.20.2026
ISSUED FOR COUNTY REVIEW 03.24.2026
ISSUED FOR ADDENDUM A 03.27.2026
ISSUED FOR BUILDING DEPT REVIEW 04.08.2026
ISSUED FOR BUILDING DEPT REVIEW - RESUBMITTAL 05.05.2026
ISSUED FOR BUILDING DEPT CORRECTIONS 05.20.2026
ID5.1
CONSTRUCTION DETAILS
A
A
A
SCALE
NTSTYPICAL GYPSUM BOARD CEILING
NOTES:
1.PROVIDE LATERAL FORCE BRACING PER DETAIL 3/ID5.2, SIMILAR.
2.VERTICAL SUPPORT SHALL BE PROVIDED AS REQUIRED IN CHAPTER 47 OF THE UNIFORM BUILDING CODE,
WITH THE ADDED REQUIREMENT THAT DISCONTINUOUS ENDS OF CROSS-RUNNERS AND MAIN RUNNERS
SHALL BE VERTICALLY SUPPORTED @ 8" MAX FROM SUCH DISCONTINUITIES WHICH OCCUR WHERE CEILING IS
DISRUPTED BY A WALL.
3.PROVIDE 118" x 112" x 20 GA ANGLE AT END OF EACH STUD TO CHANNEL.
#12 GA SPLAY BRACED
WIRES. REFER TO DETAIL 6
& 7 ON THIS SHEET
8 GA VERTICAL WIRE @
4'-0" O.C. FOR
ATTACHMENT TO STRUCT.
ABOVE SEE DETAIL 6 ON
THIS SHEET
REFER TO SCHEDULE
3/ID5.2
112" 1.12 LBS/FT METAL
CHANNEL @ 4'-0" OC
METAL FURRING CLIPS OR
MIN 2 STRANDS 18 GA
WIRE TIES
1/4" MACHINE BOLT
7/8" x 26 GA GALV. METAL
FURRING CHANNEL 2'-0"
O.C.
5/8" TYPE "X" GYP. BD.
2
3SCALE
3" = 1'-0"HANGING SOFFIT STUD ATTACHMENT
2-1/2" MET. STUD
BLOCKING SCREWED TO
STRUCTURE ABOVE
CONT 20 GA TOP TRACK
w/ 2 1/2" FLANGES.
ATTACH TO MET. STUD
BLOCKING W/ #10 SMS
METAL STUDS, TYPICAL
ATTACH TO TRACK W/ #8 SMS
EA. SIDE OF EACH STUD
COPE FLANGES OF CROSS
STUD AS REQUIRED
SCALE
1-1/2" = 1'-0"SOFFIT CEILING DETAIL
1'
-
3
"
8'
-
6
"
A
.
F
.
F
.
VARIES - REFER TO RCP
2'-0" MAX.
5/8" GYP. BD.,
TYP.
CORNER BEAD,
TYPICAL 3-5/8" x 20 GA. METAL STUD
FRAMING @ 16" O.C.
CORNER BEAD,
TYPICAL
5/8" GYP. BD., TYP.
16 GA LEDGER TRACK
W/ #10 SCREWS @
EACH SIDE
LINE OF EXISTING
CONC. WALL
3/8" Ø x 2" EMBED HILTI
KB-TZ @ 24" O.C.
ICC# ESR-1917
3-5/8" x 20 GA. BLOCKING
@ 24" O.C. MAX.
3-5/8" x 20 GA. METAL STUD
FRAMING @ 48" O.C. FOR
ATTACHMENT TO
STRUCTURE ABOVE SEE
DETAIL 10/ID5.2
1
Sheet Title:
ISSUE DATE
ISSUE FOR PLANCHECK 12.22.2025
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ENGINEER/CONSULTANT
ARCHITECT/ENGINEER STAMP
30
5
W
4
T
H
S
T
R
E
E
T
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
1
CA
F
E
OA
S
I
S
CLIENT
www.madstudiola.com
CITY STAMP
Project Director:
Project Designer:
Project Tech:
Project No:25030.300E.M.
E.M.
S.P.
ISSUED FOR MEP 01.13.2026
ISSUED FOR PLAN CHECK COMMENTS- PLANNING DEPT.01.22.2026
ISSUED FOR PRICING 02.17.2026
ISSUED FOR PLAN CHECK COMMENTS - PLANNING DEPT.02.20.2026
ISSUED FOR COUNTY REVIEW 03.24.2026
ISSUED FOR ADDENDUM A 03.27.2026
ISSUED FOR BUILDING DEPT REVIEW 04.08.2026
ISSUED FOR BUILDING DEPT REVIEW - RESUBMITTAL 05.05.2026
ISSUED FOR BUILDING DEPT CORRECTIONS 05.20.2026
ID5.2
CONSTRUCTION DETAILS
5
6
7
8
1
2
3
4
1
1
/
2
"
1/
8
"
3"
1/
2
"
2"
1/
8
"
2" MIN.
SCHEDULED COUNTERTOP
DRAWER/
DOOR FACE AS
SCHED.
3/4" PLYWOOD SUBSTRATE
SCHEDULED COUNTERTOP
3/4" PLYWOOD
SUBSTRATE
WALL/CEILING LINE
DRAWER/DOOR FACE
PLAS. LAM. REVEAL TO
MATCH CAB. LAMINATE
DOOR FACE
UNDERCABINET LIGHT
FIXTURE AS SCHEDULED
DOOR FACE
AS OCCURS
DRAWER/
DOOR FACE AS
SCHED.
DRAWER/
DOOR FACE AS
SCHED.
DRAWER/
DOOR FACE AS
SCHED.
CAB. PULL
AS SCHED.
CAB. PULL
AS SCHED.PULL TAB AS
SCHED.
CAB. PULL AS SCHED.
SEE DET. 1/id6.0
FOR ANCHOR.
SEE DET. 2/id6.0
FOR ANCHORAGE
BACK SPLASH AS OCCURS.
SEE ELEVATIONS
SCRIBE COUNTER
TO WALL
4"
M
I
N
SCALE
3" = 1'-0"CABINET DETAILS
A
B
C
D
E
F
G
SCALE
3" = 1'-0"MILLWORK BASE ANCHORAGE DETAIL
5/8"Ø EXPANSION ANCHOR, 3
@ EACH BLOCK MIN. 4" FROM
ENDS AND 4" MIN. EMBED: HILTI
KWIKBOLT III (ICC-ES, ESR-2302)
2 X 4 WD. BLOCKING (P.T.)
BASE W/#12 x 2" CADMIUM
PLATED F.H.W.S. @ 12" O.C.
PLAS. LAM. 0/ 3/4" MDF
DOOR/DRAWER
3"
LINE OF FINISH FLOOR
4"
M
I
N
SCALE
3" = 1'-0"MILLWORK BASE ANCHORAGE DETAIL
PARTITION AS SCHEDULED
SECURE CABINETS TO WALL W/
#14 x 4" SCREWS INTO STUDS
OR BACKING PLATE @ 4" O.C.
MIN. 2 PER UNIT
1 x 3 @ MID-HEIGHT. TYP. @
ALL CASEWORK OVER 3'-6"
HIGH. SECURE TO FRAMING W/
2- #10 x 2" WOOD SCREWS @
4'-0" O.C.
BACKING PLATE SEE DETAIL
3/id6.0
SCALE
NTSMETAL SUPPORT BACKING
ISOMETRIC
METAL STUD FRAMING (PER
PARTITION TYPE) @ 16" OC
FOR LENGTH OF MILLWORK,
SHELVING ETC.
3 - #12 SMS @ EACH STUD
6" x 20 GA UNPUNCHED
BACKING TRACK
EXTEND BACKING TRACK ONE STUD PAST
END OF CABINET EACH END.
PROVIDE (2) 20 GA BACKING TRACKS AT
35" & 67" O.C.
SCALE
1-1/2" = 1'-0"BASE CABINET
BACKSPLASH WHERE
OCCURS SEE ELEVATION
1
1
/
2
"
1/
8
"
2'-1"
U.O.N ON PLAN
2'
-
1
0
"
SCHEDULED COUNTERTOP O/
3/4" PLYWOOD SUBSTRATE
CABINET DOOR -
REFER TO ELEVATIONS FOR
SCHEDULED FINISH. FOR
MILLWORK HARDWARE &
ACCESSORY SCHEDULE
REFER TO SHEET ID3.0
LINE OF FINISH FLOOR
ADJ. SHELVES ON HEAVY
DUTY MTL. PIN SUPPORTS
QUARRY COVE BASE TILE,
SEE ELEVATION
4A
id6.0
4C
id6.0
4D
id6.0
SCALE
1-1/2" = 1'-0"BASE CABINET W/ DRAWER
1
1
/
2
"
1/
8
"
2'
-
1
0
"
ADJ. SHELVES ON HEAVY
DUTY MTL. PIN SUPPORTS
6"
DRAWERS ON FULL
EXTENSION GLIDES
2'-1"
U.O.N. ON PLAN
CABINET DOOR & DRAWER -
REFER TO ELEVATIONS FOR
SCHEDULED FINISH. FOR
MILLWORK HARDWARE &
ACCESSORY SCHEDULE
REFER TO SHEET ID3.0
LINE OF FINISH FLOOR
QUARRY COVE BASE TILE,
SEE ELEVATION
BACKSPLASH WHERE
OCCURS SEE ELEVATION
SCHEDULED COUNTERTOP O/
3/4" PLYWOOD SUBSTRATE
4A
id6.0
4C
id6.0
4D
id6.0
SCALE
1-1/2" = 1'-0"BASE CABINET W/ EQUIPMENT
1
1
/
2
"
2'
-
1
0
"
UNDERCOUNTER
REFRIGERATOR,
DISHWASHER, OR ICE
MAKER; SEE EQUIPMENT
SCHEDULE TO TYPE
LINE OF FINISH FLOOR
PROVIDE END PANEL AS
REQUIRED, SEE ELEVATION
SCHEDULED COUNTERTOP O/
3/4" MDF SUBSTRATE
BACKSPLASH WHERE
OCCURS SEE ELEVATION
2'-1"
U.O.N. ON PLAN
4A
id6.0
4D
id6.0
QUARRY COVE BASE TILE,
SEE ELEVATION
PARTIAL HEIGHT WALL WHERE
OCCURS SEE ELEVATION
SCALE
1-1/2" = 1'-0"MILWORK COUNTER W/ MTL. ANGLE
1
1
/
2
"
PARTITION AS SCHEDULED
LINE OF FINISH FLOOR
PAINT EXPOSED STEEL
SUPPORT & SUBSTRATE.
CONFIRM COLOR
2'
-
1
0
"
M
A
X
.
A
D
A
H
T
.
RAKKS SURFACE MOUNT
SUPPORT BRACKETS, OR
APPROVED EQUAL
2'-1"
U.O.N. ON PLANS
SCRIBE COUNTERTOP TO WALL
SCREW SCHEDULED
COUNTERTOP TO MTL
SUPPORT ANGLE BELOW
SCALE
1-1/2" = 1'-0"BASE CABINET W/ OPEN SHELF
1
1
/
2
"
2'
-
1
0
"
CABINET INTERIOR TO
MATCH ADJACENT
CABINET FACE
ADJ. SHELVES ON HEAVY
DUTY MTL. PIN SUPPORTS
BACKSPLASH WHERE
OCCURS SEE ELEVATION
SCHEDULED COUNTERTOP O/
3/4" PLYWOOD SUBSTRATE
2'-1"
U.O.N. ON PLAN
LINE OF FINISH FLOOR
QUARRY COVE BASE TILE,
SEE ELEVATION
4C
id6.0
4D
id6.0
PARTIAL HEIGHT WALL WHERE
OCCURS SEE ELEVATION
9
Sheet Title:
ISSUE DATE
ISSUE FOR PLANCHECK 12.22.2025
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ENGINEER/CONSULTANT
ARCHITECT/ENGINEER STAMP
30
5
W
4
T
H
S
T
R
E
E
T
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
1
CA
F
E
OA
S
I
S
CLIENT
www.madstudiola.com
CITY STAMP
Project Director:
Project Designer:
Project Tech:
Project No:25030.300E.M.
E.M.
S.P.
ISSUED FOR MEP 01.13.2026
ISSUED FOR PLAN CHECK COMMENTS- PLANNING DEPT.01.22.2026
ISSUED FOR PRICING 02.17.2026
ISSUED FOR PLAN CHECK COMMENTS - PLANNING DEPT.02.20.2026
ISSUED FOR COUNTY REVIEW 03.24.2026
ISSUED FOR ADDENDUM A 03.27.2026
ISSUED FOR BUILDING DEPT REVIEW 04.08.2026
ISSUED FOR BUILDING DEPT REVIEW - RESUBMITTAL 05.05.2026
ISSUED FOR BUILDING DEPT CORRECTIONS 05.20.2026
ID6.0
MILLWORK DETAILS
A
A
A
A
Sheet Title:
ISSUE DATE
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ENGINEER/CONSULTANT
ARCHITECT/ENGINEER STAMP
CLIENT
ISSUE FOR PLAN CHECK 02.06.2026
CITY STAMP
Project Director:
Project Designer:
Project Tech:
Project No:E.M.
E.M.
S.P
25030.300
30
5
W
4
T
H
S
T
R
E
E
T
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
1
SCALE :
PARTIAL SINGLE LINE DIAGRAM
N/A
TYPICAL ROOM CONTROLLER WIRING DETAIL
SCALE :N/A
1
2
3
4
5
6
7
8
PANEL SCHEDULES
SCALE :N/A
Sheet Title:
ISSUE DATE
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ENGINEER/CONSULTANT
ARCHITECT/ENGINEER STAMP
CLIENT
ISSUE FOR PLAN CHECK 02.06.2026
CITY STAMP
Project Director:
Project Designer:
Project Tech:
Project No:E.M.
E.M.
S.P
25030.300
30
5
W
4
T
H
S
T
R
E
E
T
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
1
Sheet Title:
ISSUE DATE
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ENGINEER/CONSULTANT
ARCHITECT/ENGINEER STAMP
CLIENT
ISSUE FOR PLAN CHECK 02.06.2026
CITY STAMP
Project Director:
Project Designer:
Project Tech:
Project No:E.M.
E.M.
S.P
25030.300
30
5
W
4
T
H
S
T
R
E
E
T
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
1
617 W. 7TH ST, STE 301
LOS ANGELES, CA 90017
E20243
213-593-9047
617 W. 7TH ST, STE 301
LOS ANGELES, CA 90017
305 W 4TH ST., SANTA ANA, CA 92701
305 W 4TH ST., SANTA ANA, CA 92701
02/05/2026
NA
213-593-9047
02/05/2026
DN
UP
DN
UP
UP
(E) WOMENS
RESTROOM
104OFFICE
111
OFFICE
110
(E) MENS
RESTROOM
103
(E) OPEN
OFFICE
106
(E)
EXIT CORRIDOR
-
(D)
(D)(D)
(D)
(E)
(E)
(E)
(E)
(E)
(E)
OPEN TO
ABOVE
(E)
(E)
(D)
DN
UP
DN
UP
UP
(E) WOMENS
RESTROOM
104OFFICE
111
OFFICE
110
(E) MENS
RESTROOM
103
(E) OPEN
OFFICE
106
(E)
EXIT CORRIDOR
-
10
3
CAFE
101
BOH
102
LOBBY
100
105
STORAGE
105
Sheet Title:
ISSUE DATE
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ENGINEER/CONSULTANT
ARCHITECT/ENGINEER STAMP
CLIENT
ISSUE FOR PLAN CHECK 02.06.2026
CITY STAMP
Project Director:
Project Designer:
Project Tech:
Project No:E.M.
E.M.
S.P
25030.300
30
5
W
4
T
H
S
T
R
E
E
T
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
1
SCALE :
NORTH
1/8" = 1'-0"SCALE :
NORTH
1/8" = 1'-0"
DN
UP
DN
UP
UP
(E) WOMENS
RESTROOM
104OFFICE
111
OFFICE
110
(E) MENS
RESTROOM
103
(E) OPEN
OFFICE
106
(E)
EXIT CORRIDOR
-
F1
F1
F2F2
F1 F1
F3F4
F3
F3
10
3
CAFE
101
BOH
102
LOBBY
100
105
STORAGE
105
DN
UP
DN
UP
UP
(E) WOMENS
RESTROOM
104OFFICE
111
OFFICE
110
(E) MENS
RESTROOM
103
(E) OPEN
OFFICE
106
(E)
EXIT CORRIDOR
-
F1
F1
F2F2
F1 F1
F3F4
F3
F3
10
3
CAFE
101
BOH
102
LOBBY
100
105
STORAGE
105
Sheet Title:
ISSUE DATE
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ENGINEER/CONSULTANT
ARCHITECT/ENGINEER STAMP
CLIENT
ISSUE FOR PLAN CHECK 02.06.2026
CITY STAMP
Project Director:
Project Designer:
Project Tech:
Project No:E.M.
E.M.
S.P
25030.300
30
5
W
4
T
H
S
T
R
E
E
T
,
S
A
N
T
A
A
N
A
,
C
A
9
2
7
0
1
SCALE :
NORTH
1/8" = 1'-0"SCALE :
NORTH
1/8" = 1'-0"
SCALE :NONE
YES NO
INSTRUCTIONS:
ORAN GE COUNTY FI RE AUTHORI TY
Plan Submittal Criteria
COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects
and RESIDENTIAL TRACT developments
· Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place.
· Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section.
· If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA.
· In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations.
· Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding
requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602.
Address Suite City
Project Scope/Business Description
1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways,
curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within
300 feet of an active or proposed oil well? Fire Master Plan (PR145)
2. Property is adjacent to a wildland area or non-irrigated native vegetation?
Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124)
3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from
an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170)
4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving
private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475)
5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000
sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable
to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless
classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration
or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses
where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories
with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285)
6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card,
button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan
depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520)
7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment;
industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible
liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium
ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations?
Special Equipment Plan (PR315, PR340-PR382)
8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft
maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if
H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240)
9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard
commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330)
10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a
commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335)
Initial each of the following two items indicating that you have read and understand the statement:
11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is
required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed
Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications.
12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located
in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327—
Initials the building department will determine specific requirements.
I certify under penalty of perjury under the laws of the State of California that the above is true:
Print Name Signature
Phone Number ( ) Date / /
Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA
review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the
applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the
appropriate plans and fees for OCFA review. 10-08-14 EE
COM
O R A N G E C O U N T Y F I R E A U T H O R I T Y
Plan Referral Form
Required for OCFA to review plans upon the request of the Building Department when
the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”.
City / County Official Requesting Review:
City / County Reference #: Date: __________________________________
City / County: _____________________________________ E-Mail: __________________________________
Contact Name: _____________________________________ Phone #: _________________________________
Title: _____________________________________
** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. **
Reason(s) for Review:
Please describe why OCFA Plan Review is or may be required by the City/County :
OCFA COMMENTS:
No further action required on this specific plan type, based
on information provided on: ____/______/______.
Project to be taken in for OCFA Review.
Other:
Name: _________________________________________
Contact #: ______________________________________ Date: _________________________________
OCFA Authorization
Updated: 06/02/2020 rs