HomeMy WebLinkAbout1201-1235 E Wilshire Ave & 1401-1403, 1425 S Minnie St - PlanD:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG LEGEND AND ABBREVIATIONS DISCLAIMER: PLEASE NOTE THAT THE ABBREVIATIONS, ANNOTATIONS, AND SYMBOLS LISTED ARE INTENDED TO ILLUSTRATE THOSE THAT ARE COMMONLY USED; NOT ALL ARE NECESSARILY UTILIZED WITHIN THIS SET OF DRAWINGS. ATTIC VENT FLUSH ATTIC VENT PVC PIPE VENT SATELLITE DISH T-VENT CHIMNEY FIRE SETBACKS METAL PIPE VENT HARDSCAPE PROPERTY LINEPL MAIN PANEL & SUB PANELS INVERTER(S) WITH INTEGRATED DC DISCONNECT AND AFCI GENERAL LOCATION OF EQUIPMENT METER SOCKET & DISCONNECTS PV LOAD CENTER BESS (IF APPLICABLE) GENERAL NOTES VICINITY MAP AMPERE ALTERNATING CURRENT AC DISCONNECT AMERICANS WITH DISABILITIES ACT AVAILABLE FAULT CURRENT AMERICAN SOCIETY FOR TESTING AND MATERIALS BATTERY ENERGY STORAGE SYSTEM BUILDING CLEAR CANOPY, NEW CONCRETE CONDITIONS OF USE CANOPY, RETROFIT DIRECT CURRENT DIAMETER DISTANCE EQUAL EQUIPMENT GROUNDING CONDUCTOR EXISTING EACH ELECTRICAL METALLIC TUBING GALVANIZED GROUNDING ELECTRODE CONDUCTOR GROUND HOT DIPPED GALVANIZED CURRENT CURRENT AT MAX POWER INVERTERS SHORT CIRCUIT CURRENT KILOVOLT AMPERE KILOWATT KILOWATT-HOUR LOAD BEARING WALL MAXIMUM MINIMUM NEW NATIONAL ELECTRIC CODE NOT IN CONTRACT NOT TO SCALE ON CENTER OVERCURRENT PROTECTION POWER CONTROL SYSTEM PROPERTY LINES PHOTOVOLTAIC POLYVINYL CHLORIDE ROOF, BALLAST ROOF, FLUSH MOUNT SCHEDULE SQUARE INCHES STAINLESS STEEL SEE STRUCTURAL DRAWINGS STANDARD TESTING CONDITIONS TYPICAL UNLESS OTHERWISE NOTED UNINTERRUPTIBLE POWER SUPPLY VERIFY IN FIELD VOLT VOLTAGE AT MAX POWER VOLTAGE AT OPEN CIRCUIT WATT NEMA 3R, RAINTIGHT A AC ACDS ADA AFC ASTM BESS BLDG CLR CN CONC C.O.U CR DC DIA DIST EQ EGC (E) EA. EMT GALV GEC GND HDG I Imp INVS Isc kVA kW kWh LBW MAX MIN (N) NEC NIC NTS OC OCP PCS PL PV PVC RB RF SCH SQ. IN. SS SSD STC TYP UON UPS VIF V Vmp Voc W 3R ABBREVIATIONS DESIGN WIND SPEED: 96 MPH EXPOSURE: B SNOWLOAD: 0 PSF WEATHER STATION: POLARIS DATA DESIGN LOW TEMP: -2°C 2% DRY BULB: 38°C SDS: 1.023 MOUNTING PLANE HEIGHT(S): 20 FT BUILDING STORIES: 2/1 CONSTRUCTION TYPE: V-A OCCUPANCY GROUP: R-2 AUTOMATIC FIRE SPRINKLERS: No PROJECT INFORMATION RAIL STANDOFFS & FOOTINGS SOLAR MODULES AERIAL MAP SITE NOTES: ·A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. ·THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. ·THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. ·PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. ·ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE. ·NO CHANGE TO PARKING OR STRIPING ·PV MODULES ARE TYPE I FIRE RATED AND THE CANOPY STRUCTURE IS OPEN AIR AND NON-HABITABLE. EQUIPMENT LOCATIONS: ·ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26. ·WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND NEC TABLES 310.15 (B)(1) AND 310.15 (B)(2) IF RACEWAYS ARE < 7/8" ABOVE THE ROOF. ·JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO NEC 690.34. ·ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. ·ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC APPLICABLE CODES. ·ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. STRUCTURAL NOTES: ·RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAIL MANUFACTURER’S INSTRUCTIONS. ·JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL REQUIREMENTS. ·ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED W/ APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. ·ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. ·WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: ·DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS). ·DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH. ·DC DISCONNECT INTEGRATED INTO ROOFTOP DC COMBINER OR INSTALLED WITHIN 6 FT, ACCORDING TO NEC 690.15(B). ·ALL PV CIRCUITS LOCATED OUTSIDE THE ARRAY BOUNDARY OR MORE THAN 3 FT FROM THE POINT OF ENTRY INSIDE A BUILDING SHALL BE LIMITED TO NOT MORE THAN 30 VOLTS WITHIN 30 SECONDS, CIRCUITS INSIDE THE ARRAY BOUNDARY OR NOT MORE THAN 3 FT FROM THE POINT OF PENETRATION SHALL BE LIMITED TO NOT MORE THAN 80 VOLTS UPON RAPID SHUT-DOWN INITIATION PER 690.12. ·ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9, AND 240. WIRING & CONDUIT NOTES: ·ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. ·CONDUCTORS SIZED ACCORDING TO NEC 690.8, NEC 690.7. ·ALL CONDUIT MUST ACCOUNT FOR ENVIRONMENTAL CONDITIONS AND THERMAL EXPANSIONS ACCORDING TO NEC 300.7. ·PV WIRE BLACK WIRE MAY BE FIELD-MARKED BY MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING, MARKING TAPE, TAGGING, OR OTHER APPROVED MEANS. ·MODULE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY. ·RACKING, MID CLIPS, END CLIPS, AND MODULES UL2703 LISTED ·ACCORDING TO NEC 200.7, SYSTEMS DC CONDUCTORS COLORED OR MARKED AS FOLLOWS: ···DC POSITIVE- RED, OR OTHER COLOR EXCLUDING WHITE, GRAY AND GREEN ···DC NEGATIVE- BLACK, OR ANY COLOR EXCLUDING WHITE, GRAY AND GREEN ·AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: ···PHASE A OR L1- BLACK ···PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE ···PHASE C OR L3- BLUE, YELLOW, ORANGE*, OR OTHER CONVENTION ···NEUTRAL- WHITE OR GRAY *IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [NEC 110.15]. CODES AND STANDARDS SHEET INDEXBILL OF MATERIALS NEW PV AND ENERGY STORAGE SYSTEM: ON ROOF PV SYSTEM: 259.12 DCkW, 186.2 ACkW, 241.45 CEC ACkW ENERGY STORAGE SYSTEM: 184.8 ACkW, 523.8 kWH WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN #: 014-251-49/014-251-50 BUILDING: IBC 2024 LOCAL BUILDING: CBC 2025 OCCUPANCY GROUP: R-2 ELECTRICAL: NEC 2023 LOCAL ELECTRICAL: CEC 2025 FIRE: CFC 2025 AHJ: CA-CITY OF SANTA ANA UTILITY: SCE C100 : COVERSHEET E100 : ELECTRICAL SITE PLAN E101 : ELECTRICAL SITE PLAN E102 : ELECTRICAL SITE PLAN E200 : ELECTRICAL PLAN VIEWS E201 : ELECTRICAL PLAN VIEWS E202 : ELECTRICAL PLAN VIEWS E300 : ELECTRICAL STRINGING E301 : ELECTRICAL STRINGING E302 : ELECTRICAL STRINGING E303 : ELECTRICAL STRINGING E400 : ELECTRICAL DETAILS E401 : ELECTRICAL DETAILS E500 : ELECTRICAL NOTES E600 : ONELINE DIAGRAM POI-1 E601 : ONELINE DIAGRAM POI-2 E602 : ONELINE DIAGRAM POI-3 E603 : ONELINE DIAGRAM POI-4 E604 : ONELINE DIAGRAM POI-5 E605 : ONELINE DIAGRAM POI-6 E606 : ONELINE DIAGRAM POI-7 E800 : WARNING LABELS E801 : WARNING LABELS E810 : SITE PLACARDS S100 : STRUCTURAL SITE PLAN S200 : STRUCTURAL ARRAY DETAIL S201 : STRUCTURAL ARRAY DETAIL S202 : STRUCTURAL ARRAY DETAIL S203 : STRUCTURAL ARRAY DETAIL S300 : STRUCTURAL SIDE SECTIONS S400 : STRUCTURAL ATTACHMENT DETAILS S401 : STRUCTURAL ATTACHMENT DETAILS S500 : EQUIPMENT PAD R100 : REFERENCE SHEETS R101 : REFERENCE SHEETS R102 : REFERENCE SHEETS R103 : REFERENCE SHEETS R104 : REFERENCE SHEETS R105 : UL9540A R106 : UL9540A R107 : UL9540A MODULES: (632) QCELLS NORTH AMERICA Q.PEAK DUO BLK ML-G10.C+ 410 OPTIMIZERS: (632) SOLAREDGE U650 INVERTERS: (11) SOLAREDGE SE11400H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM] (8) SOLAREDGE SE7600H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM] MONITORING: (19) CELL-B-R05-US-S-S2 BESS: (54) SOLAREDGE BAT-10K1P (19) SOLAREDGE HOME NET CARD (54) SEDG FLOOR MOUNT RACKING: FLUSH ROOF: ULTRAFOOT RAFTER - 1 LAG FLAT ROOF: SNAPNRACK TILT KIT - OMNIBASE SCOPE OF WORK INSTALL 259.12 kW-DC OF PV AND 523.8 kWh OF ESS AT SEVEN (7) DIFFERENT INTERCONNECTION POINTS (POIs) AT WILSHIRE MINNIE APARTMENTS: POI #PV LOCATION PV kW ESS Location ESS QTY ESS kWh INTERCONNECTION LOCATION 1 1201 E WILSHIRE AVE 19.68 1209 3/4 E WILSHIRE AVE UNIT# ELE01 12 116.4 1209 E WILSHIRE AVE UNIT# MTR021209 E WILSHIRE AVE 17.22 1213 E WILSHIRE AVE 17.22 2 1221 E WILSHIRE AVE 17.22 1221 3/4 E WILSHIRE AVE UNIT# ELE01 9 87.3 1221 E WILSHIRE AVE UNIT# MTR02 1225 E WILSHIRE AVE 30.34 3 1229 E WILSHIRE AVE 29.52 1229 3/4 E WILSHIRE AVE UNIT# ELE01 9 87.3 1229 E WILSHIRE AVE UNIT# MTR02 1235 E WILSHIRE AVE 17.22 4 1233 E WILSHIRE AVE 28.70 ESS CONCRETE PAD 6 58.2 1233 E WILSHIRE AVE UNIT# MTR01 5 1401 S MINNIE ST 35.67 1401 S MINNIE ST (WALL MOUNT)6 58.2 1401 S MINNIE ST UNIT# MTR01 6 1403 S MINNIE ST 22.96 1403 S MINNIE ST (WALL MOUNT)6 58.2 1403 S MINNIE ST UNIT# MTR01 7 1425 S MINNIE ST 23.37 1425 S MINNIE ST (WALL MOUNT)6 58.2 1425 S MINNIE ST UNIT# MTR01 TOTALS 259.12 54 524 D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG COVER SHEET CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH C100 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #ESTAMP #SSTAMP WILSHIRE MINNIE 1209 E WILSHIRE AVE UNIT# MTR02 1209 3/4 E WILSHIRE AVE UNIT# ELE01 1221 E WILSHIRE AVE UNIT# MTR02 1221 3/4 E WILSHIRE AVE UNIT# ELE01 1229 E WILSHIRE AVE UNIT# MTR02 1229 3/4 E WILSHIRE AVE UNIT# ELE01 1233 E WILSHIRE AVE UNIT# MTR01 1401 S MINNIE ST UNIT# MTR01 1403 S MINNIE ST UNIT# MTR01 1425 S MINNIE ST UNIT# MTR01 APN: 014-251-49 / 014-251-50 DEVELOPER: C&C DEVELOPMENT PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PLPLPLPLPLPLPLPLPL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL 1209 E WILSHIRE AVE 1213 E WILSHIRE AVE 1221 E WILSHIRE AVE 1225 E WILSHIRE AVE 1229 E WILSHIRE AVE 1233 E WILSHIRE AVE 1401 S MINNIE ST 1409 S MINNIE ST 1413 S MINNIE ST 1421 S MINNIE ST 1235 E WILSHIRE AVE POI POI PO I POI PO I POI POI POI PO I POI POI (N) CONDUIT RUN (ENTRENCHED ~ 30 FT) (N) CONDUIT RUN (ENTRENCHED ~ 10 FT) (N) CONDUIT RUN (ENTRENCHED ~ 20 FT) (N) CONDUIT RUN (ENTRENCHED ~ 6 FT) (N) CONDUIT RUN (ENTRENCHED ~ 10 FT) 1425 S MINNIE ST 1429 S MINNIE ST S S T A N D A R D A V E MI N N I E S T E WILSHIRE AVE (N) CONDUIT RUN (ENTRENCHED ~ 13 FT) (N) CONDUIT RUN (ENTRENCHED ~ 10 FT) RB03 TL: 5° AZ: 270° RB04 TL: 5° AZ: 90° RB05 TL: 5° AZ: 270° RB06 TL: 5° AZ: 90° RB07 TL: 5° AZ: 270° RB08 TL: 5° AZ: 90° RB09 TL: 5° AZ: 322° RB10 TL: 5° AZ: 142° RB11 TL: 5° AZ: 180° RB12 TL: 5° AZ: 180° RB13 TL: 5° AZ: 270° RB14 TL: 5° AZ: 90° RF01 TL: 10° AZ: 270° RF02 TL: 10° AZ: 90° RF03 TL: 10° AZ: 270° RF04 TL: 10° AZ: 90° RF05 TL: 19° AZ: 270° RF06 TL: 19° AZ: 90° RF07 TL: 15° AZ: 0° RF08 TL: 15° AZ: 270° RF09 TL: 15° AZ: 180° RF10 TL: 15° AZ: 90° RF11 TL: 10° AZ: 0° RF12 TL: 10° AZ: 180° RF13 TL: 10° AZ: 270° RF14 TL: 10° AZ: 90° S200 A S201 A S201 B S202 A S202 B S203 B S203 A 1433 S MINNIE ST 1437 S MINNIE ST FIRE SETBACKS (3' TYP) ROOF PATHWAY (3' TYP) 4' PERIMETER SETBACKS ROOF PATHWAY (3' TYP) FIRE SETBACKS (3' TYP) APN #: 014-251-50 APN #: 014-251-49 S203 A 1439 S MINNIE ST 1201 E WILSHIRE AVE RB01 TL: 5° AZ: 270° RB02 TL: 5° AZ: 90° 4' PERIMETER SETBACKS 1403 S MINNIE ST 1229 3/4 E WILSHIRE AVE UNIT# ELE01 1221 3/4 E WILSHIRE AVE UNIT# ELE01 1209 3/4 E WILSHIRE AVE UNIT# ELE01 (N) SOLAR CANOPY STRUCTURAL COLUMN DOWN SLOPE FLUSH FOOTING RAIL LEGEND ATTIC VENT FLUSH ATTIC VENT PVC PIPE VENT SATELLITE DISH T-VENT CHIMNEY FIRE SETBACKS METAL PIPE VENT HARDSCAPE PROPERTY LINEPL PITCH 2° X XX DETAIL CUT SHEET NUMBER X XX SECTION CUT SHEET NUMBER GENERAL NOTES RAIL STANDOFFS & FOOTINGS SOLAR MODULES ·ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND ANY OTHER REGULATING AUTHORITIES WHICH HAVE AUTHORITY OVER ANY PORTION OF THE WORK. ·DRAWINGS HAVE BEEN DETAILED IN COMPLIANCE WITH UL LISTING REQUIREMENTS, OSFM SOLAR PHOTOVOLTAIC INSTALLATION REQUIREMENTS, AND BUILDING CODES FOR THE MATERIALS SPECIFIED. PRIOR TO COMMENCEMENT OF ANY WORK, THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND NOTIFY THE DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE FROM SUNRUN OF ANY DISCREPANCIES. ANY WORK PERFORMED IN CONFLICT WITH THE CONTRACT DOCUMENTS SHALL BE CORRECTED AT THE SUBCONTRACTORS SOLE EXPENSE. ·SUBCONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO SUNRUN FOR APPROVAL BEFORE MAKING ANY CHANGES OR DEVIATION FROM PLANS BEFORE WRITTEN APPROVAL FROM SUNRUN PLACES LIABILITY ON THE SUBCONTRACTOR. ·ALL EQUIPMENT SHALL BE MOUNTED AS SHOWN. WHERE DETAILS ARE NOT PROVIDED, CONTRACTOR SHALL USE STANDARD CONSTRUCTION PRACTICES. ·ALL SURFACES SHALL BE PATCHED AND PAINTED AROUND NEW DEVICES AND EQUIPMENT TO MATCH EXISTING FINISHES. ANY METAL SHAVINGS FROM SITE WORK SHALL BE CLEANED FROM ALL SURFACES WHERE OXIDIZED OR CONDUCTIVE METAL SHAVINGS MY CAUSE RUST, ELECTRICAL SHORT CIRCUITS, OR OTHER DAMAGE. ·BEAMS OR PURLINS SHALL NOT BE DRILLED UNLESS AUTHORIZED OR SHOWN IN THE DRAWINGS. ·APPROVALS FROM BUILDING INSPECTORS SHALL NOT CONSTITUTE AUTHORITY TO DEVIATE FROM THE DRAWINGS. ·NO CHANGE TO PARKING OR STRIPING LAYOUT. ·IT IS THE RESPONSIBILITY OF THE INSTALLER TO ENSURE THAT RACKING SYSTEMS ARE BUILT PER THE INSTALLATION MANUAL AND MEET ALL LOCAL BUILDING CODES. IT IS ALSO THE RESPONSIBILITY OF THE INSTALLER TO CHECK THE BUILDING FOR STRUCTURAL ADEQUACY AND MAKE THE FINAL DETERMINATION ON CONTINUOUS ARRAY LENGTH TO ACCOUNT FOR THERMAL EXPANSION AND CONTRACTION OF THE SYSTEM. ·FOR BALLASTED RACKING THE CONTRACTOR SHALL FIELD VERIFY THE ROOF IS SLOPED AT 1/4" PER FOOT OR MORE TO LIMIT EFFECTS OF PONDING. IF ROOF SLOPE IS LESS THAN 1/4" PER FOOT, THE CONTRACTOR SHALL NOTIFY THE SEOR AND/OR SUNRUN PRIOR TO MOVING FORWARD WITH CONSTRUCTION. CANOPY FOOTING XX## TL: ##° AZ: ###° ROOF IDENTIFIER MOUNTING INDEX MOUNTING TYPE TILT AZUMUTH ROOF FRAMING D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG STRUCTURAL PLAN CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH S100 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & SCALE: 1" = 40' #SSTAMP IFC SECTION 1205.2 ACCESS PATHWAYS BLDG NUMBER PLAN VIEW AREA (sqft) MODULE COUNT COVERAGE (%) 1225 3023.5 74 53.2% 1229 3036.7 72 51.5% 1235 2045.1 42 44.6% 1401 4332.9 87 43.6% 1425 3711.3 57 33.4% Totals 16150 332 WILSHIRE MINNIE 1209 E WILSHIRE AVE UNIT# MTR02 1209 3/4 E WILSHIRE AVE UNIT# ELE01 1221 E WILSHIRE AVE UNIT# MTR02 1221 3/4 E WILSHIRE AVE UNIT# ELE01 1229 E WILSHIRE AVE UNIT# MTR02 1229 3/4 E WILSHIRE AVE UNIT# ELE01 1233 E WILSHIRE AVE UNIT# MTR01 1401 S MINNIE ST UNIT# MTR01 1403 S MINNIE ST UNIT# MTR01 1425 S MINNIE ST UNIT# MTR01 APN: 014-251-49 / 014-251-50 DEVELOPER: C&C DEVELOPMENT (N) SOLAR CANOPY STRUCTURAL COLUMN LEGEND ATTIC VENT FLUSH ATTIC VENT PVC PIPE VENT SATELLITE DISH T-VENT CHIMNEY FIRE SETBACKS METAL PIPE VENT HARDSCAPE PROPERTY LINEPL CLAMPING ZONES RAIL STANDOFFS & FOOTINGS SOLAR MODULES XX## TL: ##° AZ: ###° ROOF IDENTIFIER MOUNTING INDEX MOUNTING TYPE TILT AZUMUTH DOWN SLOPE FLUSH FOOTING RAIL PITCH 2° CANOPY FOOTING Q.PEAK DUO BLK ML-G10.C+ 410 [DCC] LANDSCAPE CLAMP ZONE 0.79" TO 7.87" 0.8 18.9 19.7 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC] PORTRAIT CLAMP ZONE 0.79" TO 19.7" 0.8 7.1 7.9 ROOF FRAMING MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF WIND SPEED: 96 MPH LAG SCREWS: 5/16"x3.5": 2.5" MIN EMBEDMENT NOTE: INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND SLOPED SPANS, AND NOTIFY E.O.R. OF ANY DISCREPANCIES BEFORE PROCEEDING. ADDITIONAL DETAILS WINDZONES 1209 E WILSHIRE AVE 1213 E WILSHIRE AVE RB03 TL: 5° AZ: 270° RB04 TL: 5° AZ: 90° RB05 TL: 5° AZ: 270° RB06 TL: 5° AZ: 90° 1201 E WILSHIRE AVE RB01 TL: 5° AZ: 270° RB02 TL: 5° AZ: 90° D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG STRUCTURAL DETAIL CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH S200 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #SSTAMP SCALE: 1/8" = 1'-0" ADDRESS 1201,1209 & 1213 DETAIL • POI-1A 78 ' - 1 " 37'-5" 77 ' - 3 " 37'-8" 77 ' - 6 " 36'-11" A S300 7' - 4 " 14 ' - 1 1 " 4'-8"5'-2" POI-1 ROOF SCHEDULE ADDRESS LABEL RACKING TILT (DEG)AZIMUTH (DEG) BUILDING HEIGHT (FT) MODULE COUNT MODULE AREA (SQFT)KW DC 1201 RB01 FIXED TILT 5°270°20 20 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]422.4 8.20 1201 RB02 FIXED TILT 5°90°20 28 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]591.4 11.48 1209 RB03 FIXED TILT 5°270°20 21 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]443.5 8.61 1209 RB04 FIXED TILT 5°90°20 21 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]443.5 8.61 1213 RB05 FIXED TILT 5°270°20 17 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]359.1 6.97 1213 RB06 FIXED TILT 5°90°20 25 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]528.0 10.25 Totals 132 2788 54 6' T Y P . WILSHIRE MINNIE 1209 E WILSHIRE AVE UNIT# MTR02 APN: 014-251-49 DEVELOPER: C&C DEVELOPMENT 2"x4" RAFTERS @ 24" O.C. TYP.2"x4" RAFTERS @ 24" O.C. TYP.2"x4" RAFTERS @ 24" O.C. TYP. (N) SOLAR CANOPY STRUCTURAL COLUMN LEGEND ATTIC VENT FLUSH ATTIC VENT PVC PIPE VENT SATELLITE DISH T-VENT CHIMNEY FIRE SETBACKS METAL PIPE VENT HARDSCAPE PROPERTY LINEPL CLAMPING ZONES RAIL STANDOFFS & FOOTINGS SOLAR MODULES XX## TL: ##° AZ: ###° ROOF IDENTIFIER MOUNTING INDEX MOUNTING TYPE TILT AZUMUTH DOWN SLOPE FLUSH FOOTING RAIL PITCH 2° CANOPY FOOTING Q.PEAK DUO BLK ML-G10.C+ 410 [DCC] LANDSCAPE CLAMP ZONE 0.79" TO 7.87" 0.8 18.9 19.7 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC] PORTRAIT CLAMP ZONE 0.79" TO 19.7" 0.8 7.1 7.9 ROOF FRAMING MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF WIND SPEED: 96 MPH LAG SCREWS: 5/16"x3.5": 2.5" MIN EMBEDMENT NOTE: INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND SLOPED SPANS, AND NOTIFY E.O.R. OF ANY DISCREPANCIES BEFORE PROCEEDING. ADDITIONAL DETAILS WINDZONES 1229 E WILSHIRE AVE 1401 S MINNIE ST 1235 E WILSHIRE AVE RB10 TL: 5° AZ: 142° RF03 TL: 10° AZ: 270° RF04 TL: 10° AZ: 90° RF05 TL: 19° AZ: 270° RF06 TL: 19° AZ: 90° RF08 TL: 15° AZ: 270° S201 B S202 A 1229 3/4 E WILSHIRE AVE UNIT# ELE01 1221 E WILSHIRE AVE 1225 E WILSHIRE AVE RB07 TL: 5° AZ: 270° RB08 TL: 5° AZ: 90° RF01 TL: 10° AZ: 270° RF02 TL: 10° AZ: 90° D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG STRUCTURAL DETAIL CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH S201 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #SSTAMP SCALE: 1/8" = 1'-0" ADDRESS 1221,1225 DETAIL • POI-2A SCALE: 1/8" = 1'-0" ADDRESS 1229,1235 DETAIL • POI-3B 76 ' - 9 " 37'-6" 76 ' - 9 " 37'-5" 6' T Y P . 2'-4" 3' - 1 " 7' - 1 " 5'-7" 76 ' - 3 " 37'-9" 1' - 8 " 3' - 1 " 4' - 2 " 3' - 4 " A S300 B S300 2"x6" RAFTERS @ 24" O.C. TYP. 2"x6" RAFTERS @ 24" O.C. TYP. 2"x6" RAFTERS @ 24" O.C. TYP. POI-2 ROOF SCHEDULE ADDRESS LABEL RACKING TILT (DEG)AZIMUTH (DEG)BUILDING HEIGHT (FT) MODULE COUNT MODULE AREA (SQFT)KW DC 1221 RB07 FIXED TILT 5°270°20 25 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]528.0 10.25 1221 RB08 FIXED TILT 5°90°20 17 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]359.1 6.97 1225 RF01 FLUSH MOUNT 10°270°20 32 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]675.9 13.12 1225 RF02 FLUSH MOUNT 10°90°20 42 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]887.1 17.22 Totals 116 2450 48 POI-3 ROOF SCHEDULE ADDRESS LABEL RACKING TILT (DEG)AZIMUTH (DEG)BUILDING HEIGHT (FT) MODULE COUNT MODULE AREA (SQFT)KW DC 1229 RF03 FLUSH MOUNT 10°270°20 40 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]844.8 16.40 1229 RF04 FLUSH MOUNT 10°90°20 32 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]675.9 13.12 1235 RF05 FLUSH MOUNT 19°270°20 20 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]422.4 8.20 1235 RF06 FLUSH MOUNT 19°90°20 22 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]464.7 9.02 Totals 114 2408 47 6' T Y P . WILSHIRE MINNIE 1221 E WILSHIRE AVE UNIT# MTR02 1229 E WILSHIRE AVE UNIT# MTR02 APN: 014-251-49 DEVELOPER: C&C DEVELOPMENT 6' T Y P . 2"x4" RAFTERS @ 24" O.C. TYP. (N) SOLAR CANOPY STRUCTURAL COLUMN LEGEND ATTIC VENT FLUSH ATTIC VENT PVC PIPE VENT SATELLITE DISH T-VENT CHIMNEY FIRE SETBACKS METAL PIPE VENT HARDSCAPE PROPERTY LINEPL CLAMPING ZONES RAIL STANDOFFS & FOOTINGS SOLAR MODULES XX## TL: ##° AZ: ###° ROOF IDENTIFIER MOUNTING INDEX MOUNTING TYPE TILT AZUMUTH DOWN SLOPE FLUSH FOOTING RAIL PITCH 2° CANOPY FOOTING Q.PEAK DUO BLK ML-G10.C+ 410 [DCC] LANDSCAPE CLAMP ZONE 0.79" TO 7.87" 0.8 18.9 19.7 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC] PORTRAIT CLAMP ZONE 0.79" TO 19.7" 0.8 7.1 7.9 ROOF FRAMING MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF WIND SPEED: 96 MPH LAG SCREWS: 5/16"x3.5": 2.5" MIN EMBEDMENT NOTE: INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND SLOPED SPANS, AND NOTIFY E.O.R. OF ANY DISCREPANCIES BEFORE PROCEEDING. ADDITIONAL DETAILS WINDZONES 1233 E WILSHIRE AVE 1401 S MINNIE ST 1235 E WILSHIRE AVE RB09 TL: 5° AZ: 322° RB10 TL: 5° AZ: 142° 1401 S MINNIE ST RB10 TL: 5° AZ: 142° RF07 TL: 15° AZ: 0° RF08 TL: 15° AZ: 270° RF09 TL: 15° AZ: 180° RF10 TL: 15° AZ: 90° D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG STRUCTURAL DETAIL CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH S202 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #SSTAMP SCALE: 3/32" = 1'-0" ADDRESS 1233 DETAIL • POI-4A SCALE: 3/32" = 1'-0" ADDRESS 1401 DETAIL • POI-5B 116 ' - 5 " 37' 7'-1 0 " 4'-1 1 " A S300 B S300 1'-9" 9'-1" 10 " 1' - 2 " 1' 10'-5" 8'-3" 6' TYP. 3'-6" POI-4 ROOF SCHEDULE ADDRESS LABEL RACKING TILT (DEG)AZIMUTH (DEG)BUILDING HEIGHT (FT) MODULE COUNT MODULE AREA (SQFT)KW DC 1233 RB09 FIXED TILT 5°322°20 44 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]929.3 18.04 1233 RB10 FIXED TILT 5°142°20 26 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]549.1 10.66 Totals 70 1478 29 POI-5 ROOF SCHEDULE ADDRESS LABEL RACKING TILT (DEG)AZIMUTH (DEG)BUILDING HEIGHT (FT) MODULE COUNT MODULE AREA (SQFT)KW DC 1401 RF07 FLUSH MOUNT 15°0°20 39 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]823.7 15.99 1401 RF08 FLUSH MOUNT 15°270°20 5 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]105.6 2.05 1401 RF09 FLUSH MOUNT 15°180°20 39 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]823.7 15.99 1401 RF10 FLUSH MOUNT 15°90°20 4 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]84.5 1.64 Totals 87 1838 36 6' T Y P . 2"x6" RAFTERS @ 24" O.C. TYP. WILSHIRE MINNIE 1233 E WILSHIRE AVE UNIT# MTR01 1401 S MINNIE ST UNIT# MTR01 APN: 014-251-49 DEVELOPER: C&C DEVELOPMENT 2"x4" RAFTERS @ 24" O.C. TYP. (N) SOLAR CANOPY STRUCTURAL COLUMN LEGEND ATTIC VENT FLUSH ATTIC VENT PVC PIPE VENT SATELLITE DISH T-VENT CHIMNEY FIRE SETBACKS METAL PIPE VENT HARDSCAPE PROPERTY LINEPL CLAMPING ZONES RAIL STANDOFFS & FOOTINGS SOLAR MODULES XX## TL: ##° AZ: ###° ROOF IDENTIFIER MOUNTING INDEX MOUNTING TYPE TILT AZUMUTH DOWN SLOPE FLUSH FOOTING RAIL PITCH 2° CANOPY FOOTING Q.PEAK DUO BLK ML-G10.C+ 410 [DCC] LANDSCAPE CLAMP ZONE 0.79" TO 7.87" 0.8 18.9 19.7 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC] PORTRAIT CLAMP ZONE 0.79" TO 19.7" 0.8 7.1 7.9 ROOF FRAMING MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF WIND SPEED: 96 MPH LAG SCREWS: 5/16"x3.5": 2.5" MIN EMBEDMENT NOTE: INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND SLOPED SPANS, AND NOTIFY E.O.R. OF ANY DISCREPANCIES BEFORE PROCEEDING. ADDITIONAL DETAILS WINDZONES RB11 TL: 5° AZ: 180° RB12 TL: 5° AZ: 180° RB13 TL: 5° AZ: 270° RB14 TL: 5° AZ: 90° 1403 S MINNIE ST 1425 S MINNIE ST RF11 TL: 10° AZ: 0° RF12 TL: 10° AZ: 180° RF13 TL: 10° AZ: 270° RF14 TL: 10° AZ: 90° POI-7 ROOF SCHEDULE ADDRESS LABEL RACKING TILT (DEG)AZIMUTH (DEG)BUILDING HEIGHT (FT) MODULE COUNT MODULE AREA (SQFT)KW DC 1425 RF11 FLUSH MOUNT 10°0°20 16 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]337.9 6.56 1425 RF12 FLUSH MOUNT 10°180°20 23 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]485.8 9.43 1425 RF13 FLUSH MOUNT 10°270°20 8 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]169.0 3.28 1425 RF14 FLUSH MOUNT 10°90°20 10 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]211.2 4.10 Totals 57 1204 23 D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG STRUCTURAL DETAIL CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH S203 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #SSTAMP SCALE: 3/32" = 1'-0" ADDRESS 1403 DETAIL • POI-6A 82'-9" 57 ' - 1 0 " 8' - 8 " 8'-9" SCALE: 3/32" = 1'-0" ADDRESS 1425 DETAIL • POI-7B 80'-10" 56 ' - 1 1 " 5' - 1 " 8' - 3 " 4'-6" 1'-9" 1'-1" 4'-2" 4' - 2 " 7" POI-6 ROOF SCHEDULE ADDRESS LABEL RACKING TILT (DEG)AZIMUTH (DEG)BUILDING HEIGHT (FT) MODULE COUNT MODULE AREA (SQFT)KW DC 1403 RB11 FIXED TILT 5°180°20 18 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]380.2 7.38 1403 RB12 FIXED TILT 5°180°20 15 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]316.8 6.15 1403 RB13 FIXED TILT 5°270°20 6 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]126.7 2.46 1403 RB14 FIXED TILT 5°90°20 17 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]359.1 6.97 Totals 56 1183 23 B S300 A S300 6' TYP. 6' TYP. 2"x6" RAFTERS @ 24" O.C. TYP. WILSHIRE MINNIE 1403 S MINNIE ST UNIT# MTR01 1425 S MINNIE ST UNIT# MTR01 APN: 014-251-49 / 014-251-50 DEVELOPER: C&C DEVELOPMENT 2"x4" RAFTERS @ 24" O.C. TYP. (N) SOLAR CANOPY STRUCTURAL COLUMN LEGEND ATTIC VENT FLUSH ATTIC VENT PVC PIPE VENT SATELLITE DISH T-VENT CHIMNEY FIRE SETBACKS METAL PIPE VENT HARDSCAPE PROPERTY LINEPL CLAMPING ZONES RAIL STANDOFFS & FOOTINGS SOLAR MODULES XX## TL: ##° AZ: ###° ROOF IDENTIFIER MOUNTING INDEX MOUNTING TYPE TILT AZUMUTH DOWN SLOPE FLUSH FOOTING RAIL PITCH2° CARPORT FOOTING Q.PEAK DUO BLK ML-G10.C+ 410 [DCC] LANDSCAPE CLAMP ZONE 0.79" TO 7.87" 0.8 18.9 19.7 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC] PORTRAIT CLAMP ZONE 0.79" TO 19.7" 0.8 7.1 7.9 ROOF FRAMING MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF WIND SPEED: 96 MPH LAG SCREWS: 5/16"x3.5": 2.5" MIN EMBEDMENT NOTE: INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND SLOPED SPANS, AND NOTIFY E.O.R. OF ANY DISCREPANCIES BEFORE PROCEEDING. ADDITIONAL DETAILS WINDZONES BLDG 1425 BLDG 1429 RF11 TL: 10° AZ: 0° RF12 TL: 10° AZ: 180°RF13 TL: 10° AZ: 270° RF14 TL: 10° AZ: 90° RF15 TL: 10° AZ: 270° RF16 TL: 10° AZ: 90°RF17 TL: 10° AZ: 0° RF18 TL: 10° AZ: 180° C:\USERS\EMILIANO.MORALES\DESKTOP\WORKING PROJECTS\1235_WILSHIRE_MINNIE\CD100\WILSHIRE MINNIE_WORKINGDOCS_V0\WILSHIRE MINNIE.DWG STRUCTURAL DETAIL CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 PROJECT DETAILS: PV SYSTEM: ·355.88 kW DC ·250.8 kW AC ·331.612 CEC AC ENERGY STORAGE: ·243.2 kW AC ·756.6 kWH S204 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM ORIGINAL CONTRACT NUMBER: 3003197607 PJT #: PROP-001235 SCALE: 1/8" = 1'-0" BLDG 1425,1429 DETAIL • POI-10 & POI-11A 4'-2" 5' - 1 " 4' - 1 " 3'7' - 5 " 4'-2" 4'-6" 1'-10" 8' - 5 " 4'-1" 4' - 6 " 3'-7" 6'TYP.B S300 2"x6" RAFTERS @ 24" O.C. TYP. 2"x6" RAFTERS @ 24" O.C. TYP. POI-10 ROOF SCHEDULE BLDG LABEL RACKING TILT (DEG)AZIMUTH (DEG)BUILDING HEIGHT (FT)MODULE COUNT MODULE AREA (SQFT)KW DC 1425 RF11 FLUSH 10°0°20 24 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]506.9 9.84 1425 RF12 FLUSH 10°180°20 26 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]549.1 10.66 1425 RF13 FLUSH 10°270°20 8 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]169.0 3.28 1425 RF14 FLUSH 10°90°20 10 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]211.2 4.10 Totals 68 1436.2 27.9 POI-11 ROOF SCHEDULE BLDG LABEL RACKING TILT (DEG)AZIMUTH (DEG)BUILDING HEIGHT (FT)MODULE COUNT MODULE AREA (SQFT)KW DC 1429 RF15 FLUSH 10°270°20 8 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]169.0 3.28 1429 RF16 FLUSH 10°90°20 10 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]211.2 4.10 1429 RF17 FLUSH 10°0°20 20 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]422.4 8.20 1429 RF18 FLUSH 10°180°20 26 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]549.1 10.66 Totals 64 1351.7 26.2 80'-4" 80'-10" REVIEWED FOR STRUCTURAL 6/26/25 PARAPET ROOF FRAMING STRUCTURE 2"x4" @ 24" O.C. TYP.20' BUILDING HEIGHT FINISHED GRADE S401 C NOTE: DETAILS ARE APPROXIMATE AND ARE FOR SCHEMATIC PURPOSES ONLY 4' FIRE SETBACKS A STRUCTURAL SIDE SECTION - OMNIBASE TILT-KIT NTS 11.2 6.1 5° 56.9 14.9 8.3 SOLAR MODULE OMNISHIELD OMNIBASE TILT-KIT S400 C NOTE: DETAILS ARE APPROXIMATE AND ARE FOR SCHEMATIC PURPOSES ONLY FINISHED GRADE SE E T A B L E SOLAR MODULE 5'-5 1/2" (TYP.) 3'-5 1/2" (TYP.) 3/4" 6 7/8" (TYP.) (N) ULTRAFOOT RAFTER - 1 LAG ATTACHMENT B STRUCTURAL SIDE SECTIONS - ULTRAFOOT NTS SEE TABLE (E) LBW (E) CARPENTER TRUSS 2"x6" @ 24 O.C. TYP. RACKING SPAN TABLES PORTRAIT LANDSCAPE SPANS [IN] / CANTILEVER [IN]SPANS [IN] / CANTILEVER [IN] ROOF PITCH BUILDING HEIGHT INTERIOR EDGE CORNER INTERIOR EDGE CORNER 10 20 72 / 24 72 / 24 72 / 24 96 / 32 72 / 24 72 / 24 NOTE: SPAN TABLES ARE BASED ON 5/16“Ø LAG SCREW WITH AND EFFECTIVE EMBEDMENT OF 2-1/2“ INTO DOUGLAS FIR SUBSTRATE. INSTALLATIONS INTO ALTERNATE SUBSTRATES THE SPAN LENGTHS IDENTIFIED IN THE “SPAN TABLES“ SHALL BE REDUCED ACCORDING TO THE MORE RESTRICTIVE FORMULAS PROVIDED ON PAGE 3 OF THE SNAPNRACK REPORT # 2017-03227.11 EMBEDDED THROUGH FRAMING EMBEDDED THROUGH FRAMING D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG STRUCTURAL SIDE SECTIONS CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH S300 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #SSTAMP WILSHIRE MINNIE 1209 E WILSHIRE AVE UNIT# MTR02 1221 E WILSHIRE AVE UNIT# MTR02 1229 E WILSHIRE AVE UNIT# MTR02 1233 E WILSHIRE AVE UNIT# MTR01 1401 S MINNIE ST UNIT# MTR01 1403 S MINNIE ST UNIT# MTR01 1425 S MINNIE ST UNIT# MTR01 APN: 014-251-49 / 014-251-50 DEVELOPER: C&C DEVELOPMENT ULTRAFOOT FLIP CLAMP TAPPED ULTRAFOOT FLIP CLAMP THRU ULTRAFOOT BASE ANCHOR ULTRA RAIL SPRING 3.750 5/16"∅-18 X 1", SS BOLT, WIDE FLANGE, RECESSED BUTYL PAD 2.180 EXPLODED TOP ROOF RAFTER, TYP. RAFTER ATTACHMENT DETAIL SECTION VIEW ROOF DECKING, TYP. MIN 2 1/2" EMBEDMENT MODULE HEIGHT MAX: UR-40 = 4 1/2" UR-45 = 4 1/2" UR-60 = 5 1/8" (X1) 5/16"∅ S.S. LAG SCREW ULTRAFOOT ANCHOR SNAPNRACK, ULTRA RAIL FASTENER HEIGHT OFF ROOF: 5/16" C SNAPNRACK, ULTRA RAIL ULTRAFOOT NTS FASTENER CONFIGURATIONS (X2) DECKANCHORS INTO WOOD DECK (X1) LAG INTO RAFTER UR-40 RAIL | UR-45 RAIL | UR-60 RAIL FOR USE WITH SNAPNRACK ULTRA SERIES RAILS 2 1 4" 1 1 2" 1 1 2" 1 5 8"1 3 4 " 1 1 2" FOR SNAPNRACK ENGINEERING TO APPLY, THE EMBEDMENT CRITERIA SHOWN HEREIN MUST BE MET (IF CRITERIA CANNOT BE MET OR SPANS ARE NOT SUFFICIENT, CONTACT SNAPNRACK FOR SUPPORT): REFER TO SNAPNRACK INSTALLATION MANUAL FOR 5/16"Ø HARDWARE TORQUE SPECIFICATIONS. REFER TO MANUFACTUER SPECIFICATIONS FOR OTHER FASTENER TORQUE REQUIREMENTS. B REDUCED SPACING AND OVERHANG DETAIL NTS NOTE: IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" BOUNDARY REGION OF ANY ROOF PLANE EDGES (EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: ·ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50% (REFER TO TABLE ABOVE) ·ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS (REFER TO TABLE ABOVE) 12" BOUNDARY 12" SETBACK DOES NOT APPLY TO VALLEYS 48" BOUNDARY ·ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50% (REFER TO TABLE ABOVE) ·ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS (REFER TO TABLE ABOVE) PITCHED/SLOPED ROOFS - REDUCED SPACING AND OVERHANG DETAIL FOR 12" BOUNDARY REGION FLAT ROOFS - REDUCED SPACING AND OVERHANG DETAIL FOR 48" BOUNDARY REGION C ULTRA RAIL MID CLAMP NTS 1. 4 1 1.57 1.29 1. 3 3 .9 4 1 1.75 .1 9 .33 1. 4 8 .57 SNAPNRACK ULTRA END CLAMP, FITS 30MM - 46MM MODULE HEIGHTS "RAIL END OVERHANG" DISTANCE FROM RAIL END TO OUTER ROOF ATTACHMENT CENTER. NOT TO EXCEED 34% OF ALLOWABLE SPAN STRUCTURAL MEMBER "RAIL SPAN" DISTANCE BETWEEN CENTERS OF TWO ROOF ATTACHMENTS DETAIL A: SNAPNRACK, ULTRA RAIL END CLAMP BA SNAPNRACK ULTRA MID CLAMP, FITS 30MM - 46MM MODULE HEIGHTS SNAPNRACK, ULTRA RAIL PV MODULE, TYP. SNAPNRACK, ULTRA RAIL DETAIL B: SNAPNRACK, ULTRA RAIL MID CLAMP DETAIL C: PV MODULE FRAME, TYP. SNAPNRACK, UNIVERSAL END CLAMP. MODULE HEIGHT AGNOSTIC AND HIDDEN BENEATH MODULES SNAPNRACK, ULTRA RAIL SNAPNRACK, UNIVERSAL END CLAMP C PV MODULE, TYP. 3 4" MODULE SPACING PV MODULE, TYP. SNAPNRACK, ULTRA RAIL OVERVIEW OF THE SNAPNRACK ULTRA RAIL SYSTEM INSTALLED ON A TYPICAL ROOF REFER TO SPECIFIC "ATTACHMENT DETAIL" FOR DETAILS ON ATTACHING AND WATERPROOFING THE VARIOUS SNAPNRACK ROOF ATTACHMENT PRODUCTS REFER TO SPECIFIC "COMPONENT DETAIL" FOR DETAILS ON VARIOUS SNAPNRACK ACCESSARY AND COMPONENT PRODUCTS BOTH THE SNAPNRACK, UNIVERSAL END CLAMP AND SNAPNRACK, ADJUSTABLE END CLAMP CAN BE USED ON END MODULES MODULES MAY BE CLAMPED ON SHORT OR LONG SIDE PER MODULE MANUFACTURER REQUIREMENTS RAILS MAY BE MOUNTED UP/DOWN OR ACROSS THE SLOPE OF THE ROOF REFER TO SNAPNRACK INSTALLATION SPECIFICATIONS SNAPNRACK, ADJUSTABLE END CLAMP. SELECT TO MATCH MODULE HEIGHT PV MODULE, TYP. MANUAL FOR 5/16" Ø HARDWARE TORQUE SNAPNRACK, MID CLAMP. SELECT TO MATCH MODULE HEIGHT "MODULE OVERHANG" SNAPNRACK, ULTRA RAIL DISTANCE FROM RAIL SIDE TO MODULE EDGE. NOT TO EXCEED 25% OF MODULE LENGTH OR MODULE MANUFACTURER RECOMMENDATIONS SNAPNRACK, ULTRA RAIL END CAP, OPTIONAL ROOFING MATERIAL, COMP SHINGLE SHOWN, TYP. ROOF SHEATHING AND UNDERLAYMENT MATERIAL, TYP. STRUCTURAL MEMBER, WOODEN RAFTER SHOWN, TYP. SNAPNRACK ROOF ATTACHMENT, VAIRES WITH ROOF TYPE. REFER TO SPECIFIC "ATTACHMENT DETAIL" FOR ATTACHMENT & WATERPROOFING DETAILS BIN: ALL A ULTRA RAIL, SYSTEM OVERVIEW ULTRA MIDS & ENDS NTS UR-40 RAIL | UR-45 RAIL | UR-60 RAIL FOR USE WITH SNAPNRACK ULTRA SERIES RAILS 2 1 4" 1 1 2" 1 1 2" 1 5 8"1 3 4 " 1 1 2" .60 1.50 1.56 .29 35° 54°.96 .90 FLANGE LENGTH (FLAT SURFACE) .39 - 1.21 [10.0 - 30.7] FLANGE THICKNESS .05 - .10 [1.2 - 2.5] MIN BOX WIDTH .22 [5.5] MODULE FRAME GEOMETRY REQUIREMENTS .85 D ULTRA RAIL UNIVERSAL END CLAMP NTS D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG RACKING ATTACHMENT DETAILS CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH S400 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #SSTAMP WILSHIRE MINNIE 1221 E WILSHIRE AVE UNIT# MTR02 1229 E WILSHIRE AVE UNIT# MTR02 1401 S MINNIE ST UNIT# MTR01 1425 S MINNIE ST UNIT# MTR01 APN: 014-251-49 / 014-251-50 DEVELOPER: C&C DEVELOPMENT C ULTRA RAIL MID CLAMP NTS 1. 4 1 1.57 1.29 1. 3 3 .9 4 1 1.75 .1 9 .33 1. 4 8 .57 .60 1.50 1.56 .29 35° 54°.96 .90 FLANGE LENGTH (FLAT SURFACE) .39 - 1.21 [10.0 - 30.7] FLANGE THICKNESS .05 - .10 [1.2 - 2.5] MIN BOX WIDTH .22 [5.5] MODULE FRAME GEOMETRY REQUIREMENTS .85 D ULTRA RAIL UNIVERSAL END CLAMP NTS C OMNIBASE WITH STANDOFF TO RAFTER NTS *THE SNAPNRACK OMNISHIELD CAN BE USED TO CHEMICALLY FLASH LOW SLOPE ROOF APPLICATIONS. OMNISHIELD SNAPNRACK ULTRA RAIL STANDARD STANDOFF ON OMNIBASE FOR MOUNTING TO VARIOUS ROOF TYPES REFER TO SNAPNRACK ENGINEERING CHARTS FOR APPLICABLE RAIL SPANS. "BIN" NUMBER ON CHART SHOULD MATCH "BIN" NUMBER ON THIS DRAWING 5 16"Ø S.S. LAG SCREW MUST EMBED A MIN. OF 212" INTO STRUCTURAL MEMBER FOR SNAPNRACK ENGINEERING TO APPLY REFER TO SNAPNRACK INSTALLATION MANUAL SNAPNRACK OMNIBASE CAN MOUNT IN ANY ORIENTATION ON THE ROOF AND RAILS CAN MOUNT ON ANY SIDE OF THE STANDOFF POST FOR ADDITTIONAL LEVELING DETAILS, REFER TO SNAPNRACK DETAIL DRAWINGS SNR-DC-00334 AND SNR-DC-00447 FOR 5 16"Ø HARDWARE TORQUE SPECIFICATIONS SNAPNRACK STANDOFF, LENGTH VARIES 5 16"Ø S.S. LAG SCREW WITH S.S. FLAT WASHER. CHOOSE LENGTH FOR PROPER EMBEDMENT SNAPNRACK, OMNIBASE EXPLODED SNAPNRACK, UR STANDOFF CLAMP ASSEMBLY. VARIES FOR FLUSH AND TILT APPLICATIONS SNAPNRACK, ULTRA RAIL (UR-40 SHOWN) STRUCTURAL MEMBER, WOOD RAFTER, TYP. INSTALLED *FLASH BASE APPROPRIATELY FOR THE APPLICATION, REFER TO SNAPNRACK INSTALLATION MANUAL ROOF DECKING, TYP. SNAPNRACK, ULTRA RAIL (UR-40 SHOWN) 212" MIN. EMBEDMENT INTO WOOD RAFTER FOR SNAPNRACK ENGINEERING TO APPLY ATTACHMENT DETAIL STRUCTURAL MEMBER, WOOD RAFTER, TYP. 5 16"Ø S.S. LAG SCREW WITH S.S. FLAT WASHER. CHOOSE LENGTH FOR PROPER EMBEDMENT 7" STANDOFF SHOWN, LENGTH VARIES MODULE HEIGHT OFF ROOF, RANGE: (SHOWN FOR 7" STANDOFF, ADJUST PER STANDOFF LENGTH) ROOF DECKING, TYP. BASE HEIGHT: .70 3.00 4.00 OMNIBASE, TOP OMNIBASE UR-40: 73 4" - 87 8" UR-60: 83 8" - 912" THE SNAPNRACK TILT-MOUNT (FIXED TILT) IS A SIMPLE SOLUTION FOR INSTALLATIONS REQUIRING MODULE TILT BEYOND THE EXISTING ROOF SLOPE. IT IS DESIGNED FOR TILT ANGLES FROM 0°-30° ABOVE THE HORIZONTAL UTILIZING FIXED STANDOFF HEIGHTS THE SNAPNRACK TILT-MOUNT IS COMPATIBLE WITH THE VARIOUS SNAPNRACK ROOF ATTACHMENTS SHOWN. REFER TO SPECIFIC "ATTACHMENT DETAIL" REFER TO SNAPNRACK ENGINEERING CHARTS FOR APPLICABLE RAIL SPANS. "BIN" NUMBER ON CHART SHOULD MATCH "BIN" NUMBER ON THIS DRAWING REFER TO THE SNAPNRACK INSTALLATION MANUAL FOR 5 16" Ø HARDWARE TORQUE SPECIFICATIONS FOR ADDITIONAL SYSTEM REQUIREMENTS, INCLUDING MODULE OVERHANG, SEE "SNR-DC-00329 ULTRA RAIL, SYSTEM OVERVIEW, TYPICAL" SNAPNRACK TILT- MOUNT, FRONT LEG (LENGTH VARIES) PV MODULE, TYP. SNAPNRACK TILT- MOUNT, REAR LEG (LENGTH VARIES) TILT ABOVE ROOF SURFACE (5°-30°) ROOF DECKING, (ROOFING MATERIAL NOT SHOWN) FOR LEVELING REQUIREMENTS SEE "SNR-DC-00334 ULTRA RAIL, COMPONENT DETAIL, LEVELING SPACER ON STANDOFF" RAILS CAN MOUNT ON ANY SIDE OF THE STANDOFF POST FOR "ROOF PITCH" GREATER THAN 7°, "TILT ANGLE" MUST BE IN SAME DIRECTION AS "ROOF PITCH" THE SNAPNRACK OMNISHIELD CAN BE USED TO CHEMICALLY FLASH LOW SLOPE ROOF APPLICATIONS. IT IS REQUIRED WHEN DECK MOUNTING THE SNAPNRACK TILT-MOUNT KIT (FIXED TILT) DETAIL A OMNISHIELD (REFER TO SNR-DC-001255) FIXED TILT, FRONT LEG (RAIL HIDDEN) DETAIL B FIXED TILT, REAR LEG ALLOWABLE ANGLES ROOF PITCH, VARIES INSTALLED SYSTEM 5 16"-18 BOLT WITH SERRATED FLANGE NUT, S.S. SNAPNRACK STANDOFF CLAMP SNAPNRACK STANDARD STANDOFF, LENGTH VARIES: 5-12" OR 10" SNAPNRACK STANDARD STANDOFF, LENGTH VARIES: 10", 14" OR 23" SNAPNRACK ROOF ATTACHMENT - COMPATIBLE WITH ATTACHMENTS SHOWN ABOVE. REFER TO SPECIFIC SNAPNRACK "ATTACHMENT DETAIL" SNAPNRACK AP 90 L FOOT WITH UR MOUNT HARDWARE STRUCTURAL MEMBER, WOOD RAFTER SHOWN A TILT ANGLE, RELATIVE TO HORIZONTAL (30° MAX) B SNAPNRACK TILT- MOUNT, REAR LEG (LENGTH VARIES) SNAPNRACK TILT- MOUNT, FRONT LEG (LENGTH VARIES) SNAPNRACK MODULE CLAMPS PV MODULE, TYP. SNAPNRACK ULTRA RAIL A TILT-MOUNT KIT (FIXED TILT) NTS UR-40 RAIL | UR-45 RAIL | UR-60 RAIL FOR USE WITH SNAPNRACK ULTRA SERIES RAILS 2 1 4" 1 1 2" 1 1 2" 1 5 8"1 3 4 " 1 1 2" D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG RACKING ATTACHMENT DETAILS CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH S401 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #SSTAMP WILSHIRE MINNIE 1209 E WILSHIRE AVE UNIT# MTR02 1221 E WILSHIRE AVE UNIT# MTR02 1233 E WILSHIRE AVE UNIT# MTR01 1403 S MINNIE ST UNIT# MTR01 APN: 014-251-49 DEVELOPER: C&C DEVELOPMENT B SLAB GROUNDING DETAIL NTS MIN 2" LISTED SYSTEM GROUND CLAMPS - SEE NEC 250.70 NOTE: 20 FEET (6 M) OR MORE OF 1/2" (13 MM) DIAMETER REINFORCING STEEL OR #4 BARE COPPER WIRE (OR LARGER). SEE NEC 250.52 (A) (3). REINFORCING RODS THAT ARE COATED WITH A NONCONDUCTIVE MATERIAL ARE NOT ACCEPTABLE AS AN ELECTRODE. GROUND ELECTRODE – SEE NEC 250.52 (A) (3). CONCRETE SLAB GRADE GROUNDING ELECTRODE CONDUCTOR - SEE NEC 250.62 FOR MATERIAL, NEC 250.64 FOR INSTALLATION, AND NEC 250.66 FOR SIZE. 2" DIAMETER STANDARD SCH40 PIPE HOLLANDER PIPE FLANGE WITH (4) 3/8" TITAN HD STAINLESS STEEL ANCHORS 2-3/4" EMBEDMENT 1-5/8" STRUT SOLAREDGE ENERGY BANK BAT-10K1P 1 TO 4 MOUNTED TOGETHER UTILIZING FLOOR STAND KIT - C #4 REBAR EVENLY SPACED LESS THAN OR EQUAL TO 12" OC VERIFY PAD DIMENSIONS AND THICKNESS BASED ON SITE CONDITIONS A SLAB ANCHORAGE DETAIL NTS OPTIONAL ENERGY BANK WITH STACK KIT WALL BRACKET ATTACHMENT SIDE BRACKETS MIN 2" MIN 4"MIN 6" MIN 6" MIN 36" OTHER ELECTRICAL EQUIPMENT PERMITTED TO MOUNT ON BACK OF EQUIPMENT RACKING FLOOR CONNECTOR (OPTIONAL) C HOLLAENDER BASE DETAILS NTS E G DFH 1/2 E 1/2 H B C A #48H RECTANGULAR FLOOR FLANGE 29789 = 2 HOLE SCALE: HALF 29790 = 4 HOLE INCHES PIPE SIZE A B C D E F G H J 2"2.40 0.56 3.50 8.00 6.00 5.50 0.81 2"2.40 0.56 3.50 8.00 6.00 6.00 4.50 0.56 JØ DESIGN CRITERIA: MAXIMUM WEIGHT PER VERTICAL SUPPORT: 224LBS SEISMIC: SDS = 1.023G SCOPE OF WORK: 1.PROVIDE A CONCRETE SLAB TO SUPPORT THE PRE-MANUFACTURED EQUIPMENT 2.PROVIDE ANCHORAGE OF THE EQUIPMENT TO THE SLAB MATERIALS SPECIFICATIONS: 1.ALL CONCRETE SHALL BE 2,500 PSI AT 28 DAYS. WORK CAN BEGIN 14 DAYS AFTER PAD IS POURED 2.CONCRETE REINFORCING SHALL MEET THE TEMPERATURE AND SHRINKAGE REQUIREMENTS OF ACI 318. 3.ALL REBAR SHALL BE #4 60 KSI STEEL ON 16"OC OR LESS CENTERED IN 6" CONCRETE SLAB RUNNING EACH WAY WITH A MIN. 3" COVER FOR CONCRETE FACING SOIL 4.POSTS SHALL BE 2" SCH 40 STEEL PIPES 5.1-5/8" STRUTS AND HARDWARE SHALL BE USED TO ATTACH ELECTRICAL EQUIPMENT TO POSTS. 6.ALL HARDWARE FASTENERS AND WEDGE ANCHORS SHALL BE STAINLESS STEEL 5.(4) 3/8" TITAN HD STAINLESS STEEL ANCHOR WITH 2-3/4" EMBEDMENT WITH FLAT RUBBER WASHERS. A MIN. 6" DISTANCE FROM EDGE OF SLAB. 6.PATCO 585 PE DISSIMILAR METAL TAPE WHERE PIPE CONTACTS BASE 7.PADS CAN BE MOUNTED ADJACENT AND BACK-TO-BACK. 6" SPACING BETWEEN HOLLAENDER ATTACHMENTS REQUIRED. TYP. CONCRETE PAD SIZES TOTAL BATERIES CONFIGURATION X Y 6 2X3 75.2 IN 58.6 IN 9 3X3 114.4 IN 58.6 IN 12 3X4 114.4 IN 72.6 IN 15 4X4*153.6 IN 72.6 IN * ONE GROUP WILL CONTAIN 3 BATTERIES. D BESS PAD SIZES AND EXAMPLES NTS 72.6" (TYP) NOTE: USE TABLES TO DETERMINE THE DIMENSIONS OF THE PAD NEEDED. ADJACENT GROUPS OF BATTERIES MUST MAINTAIN A MIN. 8" SPACING. TYP. PAD EXAMPLE UP TO (4) SOLAREDGE ENERGY BANKS IN GROUP 36" (TYP) HOLLAENDER FLANGE W/ (4) 3/8" TITAN HD STAINLESS STEEL ANCHORS 2-3/4" EMBEDMENT MIN. 2 POSTS PER BATTERY GROUP SOLAREDGE ENERGY BANK, 1 TO 4 MOUNTED IN GROUP UTILIZING FLOOR STAND KIT TYP. PAD EXAMPLE (15) ENERGY BANK BATTERIES. 4X4 PAD CONFIGURATION SHOWN. Y X 6" THICK CONCRETE PAD 1-5/8" STRUTS AND HARDWARE CONCRETE PAD DIMENSIONS TOTAL GROUPS X BATTERIES IN GROUP Y 1 36 IN 1 36 IN 2 75.2 IN 2 41.6 IN 3 114.4 IN 3 58.6 IN 4 153.6 IN 4 72.6 IN DETAIL 1. BRACKET INSTALLATION 1.1. LEVEL THE BRACKET. 2.MARK TWO DRILLING SPOTS. 3.DRILL HOLES IN THE INSTALLATION SURFACE. 4.INSTALL THE MOUNTING BRACKET AND SECURE WITH SCREWS: 4.1.DIAMETER: 1/4" 4.2.MINIMUM EMBEDMENT: 2-1/2" (EXCLUDING TAPERED TIP) 4.3.MINIMUM FASTENER COUNT: 4 5.MOUNTING BRACKETS MUST BE PLACED ACCORDING TO MANUFACTURER GUIDELINES. 6.FASTEN BATTERY COMPONENTS TO MOUNTS PER MANUFACTURER GUIDELINES. 7.FOR EXTERIOR APPLICATIONS, M5 SEALANT SHALL BE PROVIDED AT BATTERY ANCHOR HOLES. HOLES SHALL BE FULLY CAULKED. DETAIL 2. BATTERY INSTALLATION WALL STUDS 16" FOR 24" SPACING, USE OUTER BOLT HOLES BATTERY BRACKET SOLARMOUNT BATTERY BATTERY BRACKET (2) 1/4" X 2-1/2" LAG SCREWS PER STUD, INSTALLED AT TOP AND BOTTOM OF BRACKET 2-1/2" MIN. EMBEDMENT INTO STRUCTURAL MEMBER 24" OUTER BOLT HOLE 1.SCREW IN ALL FOUR HANDLES TO THE BATTERY FRAME. MAKE SURE TO SCREW IN THE HANDLES ALL THE WAY. 2.LIFT THE BATTERY TO THE HEIGHT OF THE MOUNTING BRACKET. 3.HANG THE BATTERY ON THE MOUNTING BRACKET, WHILE HOLDING IT BY THE HANDLES. 4.SECURE WITH A MOUNTING BRACKET SCREW ON EACH SIDE. APPLY A TORQUE OF 42 in-lbs / 4.7 N*m. 5.MAINTAIN A CLEARANCE OF MIN 8" / 20 cm FROM OTHER OBJECTS. ADDITIONAL NOTES 1.IF MOUNTING IN THE PATHWAY OF A VEHICLE, BATTERY MUST BE MOUNTED AT A LEVEL ABOVE CAR BUMPER TO AVOID ANY POTENTIAL DAMAGE. 2.THIS DETAIL IS ONLY APPLICABLE FOR WOOD FRAMED WALL STUD SPACING FROM 12" (MIN) TO 24" (MAX) WITH WOOD 2X4 (MIN) NOMINAL WALL FRAMING MEMBERS. 3.ALL WALL FRAMING REFERENCED IN THE DETAILS SHALL BE SHEATHED ON A MINIMUM OF ONE SIDE AND SHALL BE PART OF THE STRUCTURE'S MAIN PERMITTED BEARING WALL AND OR LATERAL RESISTING SYSTEM. E WALL MOUNT DETAIL NTS D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG EQUIPMENT PAD CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH S500 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #SSTAMP WILSHIRE MINNIE 1209 3/4 E WILSHIRE AVE UNIT# ELE01 1221 3/4 E WILSHIRE AVE UNIT# ELE01 1229 3/4 E WILSHIRE AVE UNIT# ELE01 1233 E WILSHIRE AVE UNIT# MTR01 1401 S MINNIE ST UNIT# MTR01 1403 S MINNIE ST UNIT# MTR01 1425 S MINNIE ST UNIT# MTR01 APN: 014-251-49 / 014-251-50 DEVELOPER: C&C DEVELOPMENT POINT OF INTERCONNECTION SEE WARNING LABEL DETAIL 1/E700 PV AC DISCONNECT SEE WARNING LABEL DETAIL 2/E700 AC DISCO # LOAD CENTER SEE WARNING LABEL DETAIL 6 & 7/E700 LOAD CENTER # XX PV INVERTER AND DC DISCONNECT SWITCH SEE WARNING LABEL DETAIL 3 & 9/E700 INVERTER # XX H (N) SOLAR CANOPY STRUCTURAL COLUMN DOWN SLOPE (E) POLE-MOUNTED LIGHT FIXTURE (E) FIRE HYDRANT ELECTRICAL EQUIPMENT LEGEND MAIN PANEL & SUB PANELS INVERTER(S) WITH INTEGRATED DC DISCONNECT AND AFCI GENERAL LOCATION OF EQUIPMENT ATTIC VENT FLUSH ATTIC VENT PVC PIPE VENT SATELLITE DISH T-VENT FIRE SETBACKS METAL PIPE VENT HARDSCAPE PROPERTY LINEPL PITCH 2° POI # X XX SECTION CUT SHEET NUMBER XX X DETAIL CUT SHEET NUMBER RAIL STANDOFFS & FOOTINGS SOLAR MODULES METER SOCKET & DISCONNECTS PV LOAD CENTER POI BOUNDARY AC-X.X LC-X.X INV-X.X POI-X XX## TL: ##° AZ: ###° ROOF IDENTIFIER MOUNTING INDEX MOUNTING TYPE TILT AZUMUTH CHIMNEY ELECTRICAL CONDUIT POI TRENCHING ℄ TESLA BACKUP GATEWAY 2 (IF APPLICABLE) TESLA PAOWERWALL 2 WALL OR PAD MOUNTED (IF APPLICABLE) SOLAREDGE ENERGY BANK WALL OR PAD MOUNTED (IF APPLICABLE) PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PLPLPLPLPLPLPLPLPL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL 1209 E WILSHIRE AVE 1213 E WILSHIRE AVE 1221 E WILSHIRE AVE 1225 E WILSHIRE AVE 1229 E WILSHIRE AVE 1233 E WILSHIRE AVE 1401 S MINNIE ST 1409 S MINNIE ST 1413 S MINNIE ST 1421 S MINNIE ST 1235 E WILSHIRE AVE POI POI PO I POI PO I POI POI POI PO I POI POI (N) CONDUIT RUN (ENTRENCHED ~ 30 FT) (N) CONDUIT RUN (ENTRENCHED ~ 10 FT) (N) CONDUIT RUN (ENTRENCHED ~ 20 FT) (N) CONDUIT RUN (ENTRENCHED ~ 6 FT) (N) CONDUIT RUN (ENTRENCHED ~ 10 FT) 1425 S MINNIE ST 1429 S MINNIE ST S S T A N D A R D A V E MI N N I E S T E WILSHIRE AVE (N) CONDUIT RUN (ENTRENCHED ~ 13 FT) (N) CONDUIT RUN (ENTRENCHED ~ 10 FT) LC-7.1 INV-7.1 INV-7.2 BES-7.1-7.6 RB03 TL: 5° AZ: 270° RB04 TL: 5° AZ: 90° RB05 TL: 5° AZ: 270° RB06 TL: 5° AZ: 90° RB07 TL: 5° AZ: 270° RB08 TL: 5° AZ: 90° RB09 TL: 5° AZ: 322° RB10 TL: 5° AZ: 142° RB11 TL: 5° AZ: 180° RB12 TL: 5° AZ: 180° RB13 TL: 5° AZ: 270° RB14 TL: 5° AZ: 90° RF01 TL: 10° AZ: 270° RF02 TL: 10° AZ: 90° RF03 TL: 10° AZ: 270° RF04 TL: 10° AZ: 90° RF05 TL: 19° AZ: 270° RF06 TL: 19° AZ: 90° RF07 TL: 15° AZ: 0° RF08 TL: 15° AZ: 270° RF09 TL: 15° AZ: 180° RF10 TL: 15° AZ: 90° RF11 TL: 10° AZ: 0° RF12 TL: 10° AZ: 180° RF13 TL: 10° AZ: 270° RF14 TL: 10° AZ: 90° POI-1 AC-1.1 AC-1.2 LC-1.1 INV-1.1 INV-1.2 INV-1.3 INV-1.4 BES-1.1-1.12 POI-2 AC-2.1 AC-2.2 LC-2.1 INV-2.1 INV-2.2 INV-2.3 BES-2.1-2.9 POI-3 AC-3.1 AC-3.2 LC-3.1 INV-3.1 INV-3.2 INV-3.3 BES-3.1-3.9 BES-5.1-5.6 POI-6 AC-6.1 AC-6.2 POI-4 AC-4.1 AC-4.2 LC-4.1 INV-4.1 INV-4.2 BES-4.1-4.6 E200 E E200 F E200 G E201 B E201 C E201 D E201 D E300 A E301 A E301 B E302 A E302 B E303 B LC-6.1 INV-6.1 INV-6.2 BES-6.1-6.6 E201 C E303 A 1433 S MINNIE ST 1437 S MINNIE ST FIRE SETBACKS (3' TYP) ROOF PATHWAY (3' TYP) 4' PERIMETER SETBACKS ROOF PATHWAY (3' TYP) FIRE SETBACKS (3' TYP) APN #: 014-251-50 APN #: 014-251-49 1439 S MINNIE ST 1201 E WILSHIRE AVE RB01 TL: 5° AZ: 270° RB02 TL: 5° AZ: 90° 4' PERIMETER SETBACKS POI-5 AC-5.1 AC-5.2 LC-5.1 INV-5.1 INV-5.2 INV-5.3 E201 A 1403 S MINNIE ST 1229 3/4 E WILSHIRE AVE UNIT# ELE01 1221 3/4 E WILSHIRE AVE UNIT# ELE01 1209 3/4 E WILSHIRE AVE UNIT# ELE01 (N) SCE PV PRODUCTION METER REF MTR #: 222012-828414 ADDR: 1229 E WILSHIRE AVE UNIT# MTR02 (N) SCE PV PRODUCTION METER REF MTR #: 222013-142908 ADDR: 1233 E WILSHIRE AVE UNIT# MTR01 (N) SCE PV PRODUCTION METER REF MTR #: 222013-048110 ADDR: 1403 S MINNIE ST UNIT# MTR01 (N) SCE PV PRODUCTION METER REF MTR #: 222012-828760 ADDR: 1209 E WILSHIRE AVE UNIT# MTR02 (N) SCE PV PRODUCTION METER REF MTR #: 222010-847068 ADDR: 1221 E WILSHIRE AVE UNIT# MTR02 (N) SCE PV PRODUCTION METER REF MTR #: 222012-825599 ADDR: 1401 S MINNIE ST UNIT# MTR01 POI-7 AC-7.1 AC-7.2 (N) SCE PV PRODUCTION METER REF MTR #: 222013-124043 ADDR: 1425 S MINNIE ST UNIT# MTR01 D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG ELECTRICAL SITE PLAN CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH E100 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #ESTAMP SCALE: 1" = 40' 1.PV LAYOUT ADHERES TO CFC 2022 SECTION 1205.2.1.1 THRU 1205.2.1.3. 2.PER SECTION 1205.3 EXCEPTION, ROOF CONFIGURATION IS SIMILAR TO THAT OF A GROUP R-3 OCCUPANCY. ROOF PITCH EXCEEDS 2:12. 3.REQUIREMENTS OBSERVED TO PROVIDE ROOF ACCESS, PROVIDE SMOKE VENTILATION OPPORTUNITIES, PROVIDE EMERGENCY EGRESS FROM THE ROOF. ACCESS NOTES SITE PLAN KEY E101 E102 IFC SECTION 1205.2 ACCESS PATHWAYS BLDG NUMBER PLAN VIEW AREA (sqft) MODULE COUNT COVERAGE (%) 1225 3023.5 74 53.2% 1229 3036.7 72 51.5% 1235 2045.1 42 44.6% 1401 4332.9 87 43.6% 1425 3711.3 57 33.4% Totals 16150 332 (N) CONCRETE PAD SEE S500 (N) DC DISCONNECT WILSHIRE MINNIE 1209 E WILSHIRE AVE UNIT# MTR02 1209 3/4 E WILSHIRE AVE UNIT# ELE01 1221 E WILSHIRE AVE UNIT# MTR02 1221 3/4 E WILSHIRE AVE UNIT# ELE01 1229 E WILSHIRE AVE UNIT# MTR02 1229 3/4 E WILSHIRE AVE UNIT# ELE01 1233 E WILSHIRE AVE UNIT# MTR01 1401 S MINNIE ST UNIT# MTR01 1403 S MINNIE ST UNIT# MTR01 1425 S MINNIE ST UNIT# MTR01 APN: 014-251-49 / 014-251-50 DEVELOPER: C&C DEVELOPMENT (N) DC DISCONNECT (N) DC DISCONNECT (N) DC DISCONNECT POINT OF INTERCONNECTION SEE WARNING LABEL DETAIL 1/E700 PV AC DISCONNECT SEE WARNING LABEL DETAIL 2/E700 AC DISCO # LOAD CENTER SEE WARNING LABEL DETAIL 6 & 7/E700 LOAD CENTER # XX PV INVERTER AND DC DISCONNECT SWITCH SEE WARNING LABEL DETAIL 3 & 9/E700 INVERTER # XX H (N) SOLAR CANOPY STRUCTURAL COLUMN DOWN SLOPE (E) POLE-MOUNTED LIGHT FIXTURE (E) FIRE HYDRANT ELECTRICAL EQUIPMENT LEGEND MAIN PANEL & SUB PANELS INVERTER(S) WITH INTEGRATED DC DISCONNECT AND AFCI GENERAL LOCATION OF EQUIPMENT ATTIC VENT FLUSH ATTIC VENT PVC PIPE VENT SATELLITE DISH T-VENT FIRE SETBACKS METAL PIPE VENT HARDSCAPE PROPERTY LINEPL PITCH 2° POI # X XX SECTION CUT SHEET NUMBER XX X DETAIL CUT SHEET NUMBER RAIL STANDOFFS & FOOTINGS SOLAR MODULES METER SOCKET & DISCONNECTS PV LOAD CENTER POI BOUNDARY AC-X.X LC-X.X INV-X.X POI-X XX## TL: ##° AZ: ###° ROOF IDENTIFIER MOUNTING INDEX MOUNTING TYPE TILT AZUMUTH CHIMNEY ELECTRICAL CONDUIT POI TRENCHING ℄ TESLA BACKUP GATEWAY 2 (IF APPLICABLE) TESLA PAOWERWALL 2 WALL OR PAD MOUNTED (IF APPLICABLE) SOLAREDGE ENERGY BANK WALL OR PAD MOUNTED (IF APPLICABLE) 1209 E WILSHIRE AVE 1213 E WILSHIRE AVE 1221 E WILSHIRE AVE 1225 E WILSHIRE AVE 1229 E WILSHIRE AVE 1233 E WILSHIRE AVE 1401 S MINNIE ST 1235 E WILSHIRE AVEPO I POIPOIPOI PO I POI POI POI PO I PO I POIPOI PO I PO I POI POI POI POIPOI POI POI PO I PO I POI POI PO I POI POI POI POI PO I POI POI (N) CONDUIT RUN (ENTRENCHED ~ 30 FT) (N) CONDUIT RUN (ENTRENCHED ~ 10 FT) (N) CONDUIT RUN (ENTRENCHED ~ 20 FT) (N) CONDUIT RUN (ENTRENCHED ~ 6 FT) (N) CONDUIT RUN (ENTRENCHED ~ 10 FT) E WILSHIRE AVE (N) CONDUIT RUN (ENTRENCHED ~ 13 FT) (N) CONDUIT RUN (ENTRENCHED ~ 10 FT) RB03 TL: 5° AZ: 270° RB04 TL: 5° AZ: 90° RB05 TL: 5° AZ: 270° RB06 TL: 5° AZ: 90° RB07 TL: 5° AZ: 270° RB08 TL: 5° AZ: 90° RB09 TL: 5° AZ: 322° RB10 TL: 5° AZ: 142° RF01 TL: 10° AZ: 270° RF02 TL: 10° AZ: 90° RF03 TL: 10° AZ: 270° RF04 TL: 10° AZ: 90° RF05 TL: 19° AZ: 270° RF06 TL: 19° AZ: 90° RF07 TL: 15° AZ: 0° RF08 TL: 15° AZ: 270° RF09 TL: 15° AZ: 180° RF10 TL: 15° AZ: 90° POI-1 AC-1.1 AC-1.2 LC-1.1 INV-1.1 INV-1.2 INV-1.3 INV-1.4 BES-1.1-1.12 POI-2 AC-2.1 AC-2.2 LC-2.1 INV-2.1 INV-2.2 INV-2.3 BES-2.1-2.9 POI-3 AC-3.1 AC-3.2 LC-3.1 INV-3.1 INV-3.2 INV-3.3 BES-3.1-3.9 BES-5.1-5.6 POI-4 AC-4.1 AC-4.2 LC-4.1 INV-4.1 INV-4.2 BES-4.1-4.6 E200 E E200 F E200 G E201 B E300 A E301 A E301 B E302 A E302 B FIRE SETBACKS (3' TYP) ROOF PATHWAY (3' TYP) APN #: 014-251-49 1201 E WILSHIRE AVE RB01 TL: 5° AZ: 270° RB02 TL: 5° AZ: 90° 4' PERIMETER SETBACKS POI-5 AC-5.1 AC-5.2 LC-5.1 INV-5.1 INV-5.2 INV-5.3 E201 A 1229 3/4 E WILSHIRE AVE UNIT# ELE01 1221 3/4 E WILSHIRE AVE UNIT# ELE01 1209 3/4 E WILSHIRE AVE UNIT# ELE01 (N) SCE PV PRODUCTION METER REF MTR #: 222012-828414 ADDR: 1229 E WILSHIRE AVE UNIT# MTR02 (N) SCE PV PRODUCTION METER REF MTR #: 222013-142908 ADDR: 1233 E WILSHIRE AVE UNIT# MTR01 (N) SCE PV PRODUCTION METER REF MTR #: 222012-828760 ADDR: 1209 E WILSHIRE AVE UNIT# MTR02 (N) SCE PV PRODUCTION METER REF MTR #: 222010-847068 ADDR: 1221 E WILSHIRE AVE UNIT# MTR02 (N) SCE PV PRODUCTION METER REF MTR #: 222012-825599 ADDR: 1401 S MINNIE ST UNIT# MTR01 PL D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG ELECTRICAL SITE PLAN CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH E101 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #ESTAMP SITE PLAN KEY E101 E102 POI-1 ROOF SCHEDULE ADDRESS LABEL RACKING TILT (DEG)AZIMUTH (DEG) BUILDING HEIGHT (FT) MODULE COUNT MODULE AREA (SQFT)KW DC 1201 RB01 FIXED TILT 5°270°20 20 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]422.4 8.20 1201 RB02 FIXED TILT 5°90°20 28 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]591.4 11.48 1209 RB03 FIXED TILT 5°270°20 21 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]443.5 8.61 1209 RB04 FIXED TILT 5°90°20 21 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]443.5 8.61 1213 RB05 FIXED TILT 5°270°20 17 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]359.1 6.97 1213 RB06 FIXED TILT 5°90°20 25 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]528.0 10.25 Totals 132 2788 54 POI-2 ROOF SCHEDULE ADDRESS LABEL RACKING TILT (DEG)AZIMUTH (DEG) BUILDING HEIGHT (FT) MODULE COUNT MODULE AREA (SQFT)KW DC 1221 RB07 FIXED TILT 5°270°20 25 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]528.0 10.25 1221 RB08 FIXED TILT 5°90°20 17 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]359.1 6.97 1225 RF01 FLUSH MOUNT 10°270°20 32 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]675.9 13.12 1225 RF02 FLUSH MOUNT 10°90°20 42 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]887.1 17.22 Totals 116 2450 48 POI-3 ROOF SCHEDULE ADDRESS LABEL RACKING TILT (DEG)AZIMUTH (DEG) BUILDING HEIGHT (FT) MODULE COUNT MODULE AREA (SQFT)KW DC 1229 RF03 FLUSH MOUNT 10°270°20 40 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]844.8 16.40 1229 RF04 FLUSH MOUNT 10°90°20 32 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]675.9 13.12 1235 RF05 FLUSH MOUNT 19°270°20 20 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]422.4 8.20 1235 RF06 FLUSH MOUNT 19°90°20 22 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]464.7 9.02 Totals 114 2408 47 POI-4 ROOF SCHEDULE ADDRESS LABEL RACKING TILT (DEG)AZIMUTH (DEG) BUILDING HEIGHT (FT) MODULE COUNT MODULE AREA (SQFT)KW DC 1233 RB09 FIXED TILT 5°322°20 44 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]929.3 18.04 1233 RB10 FIXED TILT 5°142°20 26 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]549.1 10.66 Totals 70 1478 29 POI-5 ROOF SCHEDULE ADDRESS LABEL RACKING TILT (DEG)AZIMUTH (DEG) BUILDING HEIGHT (FT) MODULE COUNT MODULE AREA (SQFT)KW DC 1401 RF07 FLUSH MOUNT 15°0°20 39 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]823.7 15.99 1401 RF08 FLUSH MOUNT 15°270°20 5 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]105.6 2.05 1401 RF09 FLUSH MOUNT 15°180°20 39 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]823.7 15.99 1401 RF10 FLUSH MOUNT 15°90°20 4 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]84.5 1.64 Totals 87 1838 36 SCALE: 1" = 20' (N) DC DISCONNECT (N) DC DISCONNECT (N) DC DISCONNECT (N) DC DISCONNECT (N) DC DISCONNECT (N) DC DISCONNECT (N) DC DISCONNECT (N) DC DISCONNECT (N) CONCRETE PAD SEE S500 WILSHIRE MINNIE 1209 E WILSHIRE AVE UNIT# MTR02 1209 3/4 E WILSHIRE AVE UNIT# ELE01 1221 E WILSHIRE AVE UNIT# MTR02 1221 3/4 E WILSHIRE AVE UNIT# ELE01 1229 E WILSHIRE AVE UNIT# MTR02 1229 3/4 E WILSHIRE AVE UNIT# ELE01 1233 E WILSHIRE AVE UNIT# MTR01 1401 S MINNIE ST UNIT# MTR01 APN: 014-251-49 DEVELOPER: C&C DEVELOPMENT POINT OF INTERCONNECTION SEE WARNING LABEL DETAIL 1/E700 PV AC DISCONNECT SEE WARNING LABEL DETAIL 2/E700 AC DISCO # LOAD CENTER SEE WARNING LABEL DETAIL 6 & 7/E700 LOAD CENTER # XX PV INVERTER AND DC DISCONNECT SWITCH SEE WARNING LABEL DETAIL 3 & 9/E700 INVERTER # XX H (N) SOLAR CANOPY STRUCTURAL COLUMN DOWN SLOPE (E) POLE-MOUNTED LIGHT FIXTURE (E) FIRE HYDRANT ELECTRICAL EQUIPMENT LEGEND MAIN PANEL & SUB PANELS INVERTER(S) WITH INTEGRATED DC DISCONNECT AND AFCI GENERAL LOCATION OF EQUIPMENT ATTIC VENT FLUSH ATTIC VENT PVC PIPE VENT SATELLITE DISH T-VENT FIRE SETBACKS METAL PIPE VENT HARDSCAPE PROPERTY LINEPL PITCH 2° POI # X XX SECTION CUT SHEET NUMBER XX X DETAIL CUT SHEET NUMBER RAIL STANDOFFS & FOOTINGS SOLAR MODULES METER SOCKET & DISCONNECTS PV LOAD CENTER POI BOUNDARY AC-X.X LC-X.X INV-X.X POI-X XX## TL: ##° AZ: ###° ROOF IDENTIFIER MOUNTING INDEX MOUNTING TYPE TILT AZUMUTH CHIMNEY ELECTRICAL CONDUIT POI TRENCHING ℄ TESLA BACKUP GATEWAY 2 (IF APPLICABLE) TESLA PAOWERWALL 2 WALL OR PAD MOUNTED (IF APPLICABLE) SOLAREDGE ENERGY BANK WALL OR PAD MOUNTED (IF APPLICABLE) 1409 S MINNIE ST 1413 S MINNIE ST 1421 S MINNIE ST PO I POI POI PO I POIPOI POIPOIPOI PO I POI POI PO I POI POI 1425 S MINNIE ST LC-7.1 INV-7.1 INV-7.2 BES-7.1-7.6 RB11 TL: 5° AZ: 180° RB12 TL: 5° AZ: 180° RB13 TL: 5° AZ: 270° RB14 TL: 5° AZ: 90° TL: 15° AZ: 180° RF11 TL: 10° AZ: 0° RF12 TL: 10° AZ: 180° RF13 TL: 10° AZ: 270° RF14 TL: 10° AZ: 90° POI-6 AC-6.1 AC-6.2 E201 C E201 D E201 D E303 B LC-6.1 INV-6.1 INV-6.2 BES-6.1-6.6 E201 C E303 A 4' PERIMETER SETBACKS ROOF PATHWAY (3' TYP) FIRE SETBACKS (3' TYP) 1403 S MINNIE ST (N) SCE PV PRODUCTION METER REF MTR #: 222013-048110 ADDR: 1403 S MINNIE ST UNIT# MTR01 POI-7 AC-7.1 AC-7.2 (N) SCE PV PRODUCTION METER REF MTR #: 222013-124043 ADDR: 1425 S MINNIE ST UNIT# MTR01 PL D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG ELECTRICAL SITE PLAN CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH E102 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #ESTAMP SCALE: 1/16" = 1'-0" SITE PLAN KEY E101 E102 POI-6 ROOF SCHEDULE ADDRESS LABEL RACKING TILT (DEG)AZIMUTH (DEG) BUILDING HEIGHT (FT) MODULE COUNT MODULE AREA (SQFT)KW DC 1403 RB11 FIXED TILT 5°180°20 18 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]380.2 7.38 1403 RB12 FIXED TILT 5°180°20 15 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]316.8 6.15 1403 RB13 FIXED TILT 5°270°20 6 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]126.7 2.46 1403 RB14 FIXED TILT 5°90°20 17 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]359.1 6.97 Totals 56 1183 23 POI-7 ROOF SCHEDULE ADDRESS LABEL RACKING TILT (DEG)AZIMUTH (DEG) BUILDING HEIGHT (FT) MODULE COUNT MODULE AREA (SQFT)KW DC 1425 RF11 FLUSH MOUNT 10°0°20 16 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]337.9 6.56 1425 RF12 FLUSH MOUNT 10°180°20 23 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]485.8 9.43 1425 RF13 FLUSH MOUNT 10°270°20 8 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]169.0 3.28 1425 RF14 FLUSH MOUNT 10°90°20 10 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]211.2 4.10 Totals 57 1204 23 WILSHIRE MINNIE 1403 S MINNIE ST UNIT# MTR01 1425 S MINNIE ST UNIT# MTR01 APN: 014-251-49 / 014-251-50 DEVELOPER: C&C DEVELOPMENT FLOOR STAND KIT 16" MIN. CLEAR 3' 8" 11'-5" 11"11" 16" MIN. CLEAR 11" 4'-6" FLOOR STAND KIT 3' 8" 11'-5" 16" MIN. CLEAR 11" 4'-6" FLOOR STAND KIT 3'8" 11'-5" 16" MIN. CLEAR 11" 4'-6" 11" D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG ELECTRICAL PLAN VIEWS CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH E200 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #ESTAMP (N) PV POINT OF INTERCONNECTION (POI-1) (N) PV PRODUCTION METER SOCKET 1209 E WILSHIRE AVE UNIT# MTR02 PV PRODUCTION METER REFERENCE METER NUMBER: 222012-828760 (N) UTILITY AC DISCONNECT (ACDS-1.1) (N) MAINTENANCE AC DISCONNECT (ACDS-1.2) (N) AC LOAD CENTER (LC-1.1) (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-1.4) (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-1.1) (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-1.2) (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-1.3)(N) 77.6 kWh ESS GROUP OF (8) SOLAREDGE BAT-10K1P BATTERIES (FLOOR MOUNTED) A EQUIPMENT PLAN - POI-1 - 1209 E WILSHIRE AVE SCALE: 3/16" = 1'-0" (N) PV POINT OF INTERCONNECTION (POI-2) (N) PV PRODUCTION METER SOCKET 1221 E WILSHIRE AVE UNIT# MTR02 PV PRODUCTION METER REFERENCE METER NUMBER: 222010-847068 (N) UTILITY AC DISCONNECT (ACDS-2.1) (N) MAINTENANCE AC DISCONNECT (ACDS-2.2) (N) AC LOAD CENTER (LC-2.1) (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-2.3) (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-2.2) (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-2.1) C EQUIPMENT PLAN - POI-2 - 1221 E WILSHIRE AVE SCALE: 3/16" = 1'-0" (N) PV POINT OF INTERCONNECTION (POI-3) (N) PV PRODUCTION METER SOCKET 1229 E WILSHIRE AVE UNIT# MTR02 PV PRODUCTION METER REFERENCE METER NUMBER: 222012-828414 (N) UTILITY AC DISCONNECT (ACDS-3.1) (N) MAINTENANCE AC DISCONNECT (ACDS-3.2) (N) AC LOAD CENTER (LC-3.1) (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-3.1) (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-3.3) (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-3.2) E EQUIPMENT PLAN - POI-3 - 1229 E WILSHIRE AVE SCALE: 3/16" = 1'-0" B ESS ELEVATION - POI-1 - 1209 E WILSHIRE AVE SCALE: 1/2" = 1'-0" 1201 E WILSHIRE 1209 E WILSHIRE 1209 3/4 E WILSHIRE AVE UNIT# ELE01 (N) 38.8 kWh ESS GROUP OF (4) SOLAREDGE BAT-10K1P BATTERIES (FLOOR MOUNTED)(EACH BATTERY 9.7KWh) 1207.5.1 & UL 9540A TEST 1207.8.3 (N) 77.6 kWh ESS GROUP OF (8) SOLAREDGE BAT-10K1P BATTERIES (FLOOR MOUNTED) (N) 38.8 kWh ESS GROUP OF (4) SOLAREDGE BAT-10K1P BATTERIES (FLOOR MOUNTED) 1209 3/4 E WILSHIRE AVE UNIT# ELE01 (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-1.4) (N) PV INVERTERWITH PV+ESS DC DISCONNECT (INV-1.1) (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-1.2) (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-1.3) 1213 E WILSHIRE 1221 E WILSHIRE 1221 3/4 E WILSHIRE AVE UNIT# ELE01 1207.5.1 & UL 9540A TEST 1207.8.3 (N) 58.2 kWh ESS GROUP OF (6) SOLAREDGE BAT-10K1P BATTERIES (FLOOR MOUNTED)(EACH BATTERY 9.7KWh) (N) 29.1 kWh ESS GROUP OF (3) SOLAREDGE BAT-10K1P BATTERIES (FLOOR MOUNTED)(EACH BATTERY 9.7KWh) D ESS ELEVATION - POI-2 - 1221 E WILSHIRE AVE SCALE: 1/2" = 1'-0" 1221 3/4 E WILSHIRE AVE UNIT# ELE01 (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-2.3) (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-2.2) (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-2.1) (N) 58.2 kWh ESS GROUP OF (6) SOLAREDGE BAT-10K1P BATTERIES (FLOOR MOUNTED) (N) 29.1 kWh ESS GROUP OF (3) SOLAREDGE BAT-10K1P BATTERIES (FLOOR MOUNTED) 1207.5.1 & UL 9540A TEST 1207.8.3 1225 E WILSHIRE 1229 E WILSHIRE (N) 58.2 kWh ESS GROUP OF (6) SOLAREDGE BAT-10K1P BATTERIES (FLOOR MOUNTED)(EACH BATTERY 9.7KWh) (N) 29.1 kWh ESS GROUP OF (3) SOLAREDGE BAT-10K1P BATTERIES (FLOOR MOUNTED)(EACH BATTERY 9.7KWh) F ESS ELEVATION - POI-3 - 1229 E WILSHIRE AVE SCALE: 1/2" = 1'-0" 1229 3/4 E WILSHIRE AVE UNIT# ELE01 (N) 58.2 kWh ESS GROUP OF (6) SOLAREDGE BAT-10K1P BATTERIES (FLOOR MOUNTED) (N) 29.1 kWh ESS GROUP OF (3) SOLAREDGE BAT-10K1P BATTERIES (FLOOR MOUNTED) 1229 3/4 E WILSHIRE AVE UNIT# ELE01 (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-3.1) (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-3.3) (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-3.2) (N) DC DISCONNECTS (N) DC DISCONNECT (N) DC DISCONNECT (N) DC DISCONNECT 1207.4.2 & 110.26(A)(1) WORKING CLEARANCE 1207.4.2 & 110.26(A)(1) WORKING CLEARANCE 1207.4.2 & 110.26(A)(1) WORKING CLEARANCE WILSHIRE MINNIE 1209 E WILSHIRE AVE UNIT# MTR02 1209 3/4 E WILSHIRE AVE UNIT# ELE01 1221 E WILSHIRE AVE UNIT# MTR02 1221 3/4 E WILSHIRE AVE UNIT# ELE01 1229 E WILSHIRE AVE UNIT# MTR02 1229 3/4 E WILSHIRE AVE UNIT# ELE01 APN: 014-251-49 DEVELOPER: C&C DEVELOPMENT 3'4' - 5 " 3'3' - 3 " 3' - 3 " 3' 6' - 7 " 10 ' - 5 " 10'10' 10'17'-11 " 22'-9" 11 ' - 6 " 8"8" 8" 8"8"8" 8"8"8" 13 ' PL PL PL PL PL PL PL PL PL PL 8"8"1'-8" 8"8" 8"8"8" 4" 1'1' 4" 1'1'1' D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG ELECTRICAL PLAN VIEWS CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH E201 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #ESTAMP (N) PV POINT OF INTERCONNECTION (POI-4) (N) PV PRODUCTION METER SOCKET 1233 E WILSHIRE AVE UNIT# MTR01 PV PRODUCTION METER REFERENCE METER NUMBER: 222013-142908 (N) UTILITY AC DISCONNECT (ACDS-4.1) (N) MAINTENANCE AC DISCONNECT (ACDS-4.2) (N) AC LOAD CENTER (LC-4.1) (ON BATTERY PAD) (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-4.1) (ON BATTERY PAD) (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-4.2) (ON BATTERY PAD) (N) 58.2 kWh ESS GROUP OF (6) SOLAREDGE BAT-10K1P BATTERIES (ON BATTERY PAD SEE S500) (EACH BATTERY 9.7KWh) A EQUIPMENT PLAN - POI-4 1233 E WILSHIRE AVE SCALE: 1/4"=1'-0" (N) PV POINT OF INTERCONNECTION (POI-5) (N) PV PRODUCTION METER SOCKET 1401 S MINNIE ST UNIT# MTR01 PV PRODUCTION METER REFERENCE METER NUMBER: 222012-825599 (N) UTILITY AC DISCONNECT (ACDS-5.1) (N) MAINTENANCE AC DISCONNECT (ACDS-5.2) (N) AC LOAD CENTER (LC-5.1) (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-5.1) (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-5.2) (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-5.3) (N) 58.2 kWh ESS GROUP OF (6) SOLAREDGE BAT-10K1P BATTERIES WALL MOUNTED(EACH BATTERY 9.7KWh) B EQUIPMENT PLAN - POI-5 1401 MINNIE ST SCALE: 1/8" = 1'-0" (N) PV POINT OF INTERCONNECTION (POI-6) (N) PV PRODUCTION METER SOCKET 1403 S MINNIE ST UNIT# MTR01 PV PRODUCTION METER REFERENCE METER NUMBER: 222013-048110 (N) UTILITY AC DISCONNECT (ACDS-6.1) (N) MAINTENANCE AC DISCONNECT (ACDS-6.2) D EQUIPMENT PLAN - POI-6 1403 MINNIE ST SCALE: 1/8" = 1'-0" (N) AC LOAD CENTER (LC-6.1) (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-6.2) (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-6.1) GARBAGE BIN 4'-6 " 10' 17' 30'-2" 1207.8.3 1207.4.2 & 110.26(A)(1) 1233 E WILSHIRE 1207.8.3 1207.8.3 1207.4.2 & 110.26(A)(1) WORKING CLEARANCE (E) FENCE (N) TYP. IMPACT PROTECTION BOLLARDS 1207.4.5 & 312.2 1207.8.3 1401 MINNIE ST C ESS ELEVATION - POI-5 1401 MINNIE ST SCALE: 3/4" = 1'-0" 3' 5'- 4 " 3'-2" 13'-9" 1401 MINNIE ST (E) WINDOW (E) WINDOW 1207.8.4 & UL 9540A REPORT (N) 58.2 kWh ESS GROUP OF (6) SOLAREDGE BAT-10K1P BATTERIES WALL MOUNTED (N) 58.2 kWh ESS GROUP OF (6) SOLAREDGE BAT-10K1P BATTERIES WALL MOUNTED (EACH BATTERY 9.7KWh) 1403 MINNIE ST 1409 MINNIE ST 1207.8.3 1207.4.2 & 110.26(A)(1) WORKING CLEARANCE E ESS ELEVATION - POI-6 1403 MINNIE ST SCALE: 3/8" = 1'-0" (N) AC LOAD CENTER (LC-6.1) (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-6.2) (N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-6.1) 37' 3'-8"12'-10" (N) 58.2 kWh ESS GROUP OF (6) SOLAREDGE BAT-10K1P BATTERIES WALL MOUNTED 1403 MINNIE ST (N) DC DISCONNECT 8' - 9 " DISTANCE BETWEEN BUILDINGS (N) CONCRETE PAD SEE S500 WILSHIRE MINNIE 1233 E WILSHIRE AVE UNIT# MTR01 1401 S MINNIE ST UNIT# MTR01 1403 S MINNIE ST UNIT# MTR01 APN: 014-251-49 DEVELOPER: C&C DEVELOPMENT 30'-2" 4'3'10'-6" 3' 13'-9" 11'-10" 12'-9" 11 ' - 1 " 6' - 3 " M A X 4' - 0 " M I N FR O M G R A D E B (N) NGO METER SOCKET ≤ 200A NTS 10" MIN. MIN. CLEARANCE TO OBSTRUCTIONS OR SIDE WALLS 36" MIN. (N) HOUSEKEEPING PAD THE PAD SHALL BE FLUSH WITH THE BOTTOM OF THE SERVICE EQUIPMENT AND EXTEND A MINIMUM OF THREE FEET. 10" MIN. 18" MIN. MIN. CLEARANCE TO EDGE OF WINDOW OR DOOR - NGO METER WORKING SPACE TO BE MAINTAINED. - EQUIPMENT ABOVE OR BELOW NGOM WILL NOT EXCEED DEPTH OF NGOM. - NGOM TO BE MOUNTED ON STRUT IF NEEDED TO ACCOUNT FOR ANY DEPTH DIFFERENCES. - CENTER OF METER CAN NOT TO EXCEED 6'-3" MAX, 4'-0" MIN. -EQUIPMENT AND CONDUIT SHOWN IS DIAGRAMMATIC ONLY. SEE LINE DRAWINGS FOR CONDUIT SIZING. NOTES MIN. CLEARANCE TO PLUMBING FIXTURES EXTENDING 6" OUT FROM WALL SURFACE 6' - 6 " M I N H E I G H T CL E A R A N C E FR O M G R A D E (E) GRADE A AC DISCONNECT (E) GRADE 75 " M A X HE I G H T F R O M G R A D E NOTES - INSTALLED AT VERTICAL HIEGHT OF BEWTEEN 48" MIN AND 75" MAX, MEASURED FROM GROUND TO TOP OF ENCLOSURE -EQUIPMENT AND CONDUIT SHOWN IS DIAGRAMMATIC ONLY. SEE LINE DRAWINGS FOR CONDUIT SIZING. DISCONNECT (N) PV UTILITY DISCONNECT C INVERTER CLEARANCE - SOLAREDGE HOME HUB MIN. CLEARANCE BACK TO BACK INVERTERS 8" MIN. CLEAR 16" MIN. CLEAR 8" MIN. CLEAR MIN. CLEARANCE VERTICALLY STACKED INVERTERS 8" MIN. CLEAR MIN. CLEARANCE SIDE-BY-SIDE INVERTERS - LISTED MIN. CLEARANCES FOR INVERTER TO OTHER OBJECTS, UNLESS NOTED - MIN. CLEARANCES REQUIRED FOR HEAT DISSIPATION - CONDUIT MAY BE REQUIRE ADDITIONAL CLEARANCE -EQUIPMENT AND CONDUIT SHOWN IS DIAGRAMMATIC ONLY. SEE LINE DRAWINGS FOR CONDUIT SIZING. NOTES 8" MIN. CLEAR 4" MIN. CLEAR 4" MIN. CLEAR 4" MIN. CLEAR 46.4" 9.84" BATTERY WEIGHT: 262LBS 31.1" 8" MIN. CLEAR MIN. CLEARANCE BATTERY SHOWN ON OPTIONAL FLOOR STAND KIT SOLAREDGE ENERGY BANK BAT-10K1P D BESS CLEARANCE - SOLAREDGE ENERGY BANK ·LISTED MIN. CLEARANCES FOR ENERGY BANK TO OTHER OBJECTS AS REQUIRED BY MANUFACTURER. NEC 110.3(B) ·BATTERY CAN BE WALL MOUNTED OR USE MANUFACTURES FLOOR STAND KIT. ·8" MIN. CLEARANCES REQUIRED FOR HEAT DISSIPATION ·CONDUIT MAY REQUIRE ADDITIONAL CLEARANCE. ·EQUIPMENT AND CONDUIT SHOWN IS DIAGRAMMATIC ONLY. ·WORKING CLEARANCES SHALL BE IN ACCORDANCE WITH NEC 110.26 FOR ANY COMPONENTS THAT ARE LIKELY TO REQUIRE EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE WHILE ENERGIZED. ·BATTERIES SHALL NOT BE INSTALLED IN DIRECT SUNLIGHT WITH OUT SHADE COVER NOTES 8" MIN. CLEAR 8" MIN. CLEAR 8" MIN. CLEAR SOLAREDGE ENERGY BANK WITH 4 BATTERIES ON FLOOR STAND KITS 53.15" MIN. 6.3" 13.78" 1ST BATTERY FLOOR STAND TO BE ANCHORED TO WALL/RACK SIDE BRACKETS FOR ATTACHING BATTERIES MIN. CLEAR IF WALL MOUNTING DC CONNECTION LOCATION (N) AC DISCONNECT GENERAL NOTES ·FIELD VERIFY ALL MEASUREMENTS ·ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND ANY OTHER REGULATING AUTHORITIES WHICH HAVE AUTHORITY OVER ANY PORTION OF THE WORK. ·DRAWINGS HAVE BEEN DETAILED IN COMPLIANCE WITH UL LISTING REQUIREMENTS, OSFM SOLAR PHOTOVOLTAIC INSTALLATION REQUIREMENTS, AND BUILDING CODES FOR THE MATERIALS SPECIFIED. PRIOR TO COMMENCEMENT OF ANY WORK, THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND NOTIFY THE DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE FROM SUNRUN OF ANY DISCREPANCIES. ANY WORK PERFORMED IN CONFLICT WITH THE CONTRACT DOCUMENTS SHALL BE CORRECTED AT THE SUBCONTRACTORS SOLE EXPENSE. ·SUBCONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO SUNRUN FOR APPROVAL BEFORE MAKING ANY CHANGES OR DEVIATION FROM PLANS BEFORE WRITTEN APPROVAL FROM SUNRUN PLACES LIABILITY ON THE SUBCONTRACTOR. ·ALL EQUIPMENT SHALL BE MOUNTED AS SHOWN. WHERE DETAILS ARE NOT PROVIDED, CONTRACTOR SHALL USE STANDARD CONSTRUCTION PRACTICES. ·ALL SURFACES SHALL BE PATCHED AND PAINTED AROUND NEW DEVICES AND EQUIPMENT TO MATCH EXISTING FINISHES. ANY METAL SHAVINGS FROM SITE WORK SHALL BE CLEANED FROM ALL SURFACES WHERE OXIDIZED OR CONDUCTIVE METAL SHAVINGS MY CAUSE RUST, ELECTRICAL SHORT CIRCUITS, OR OTHER DAMAGE. ·APPROVALS FROM BUILDING INSPECTORS SHALL NOT CONSTITUTE AUTHORITY TO DEVIATE FROM THE DRAWINGS. ·ACCESS AND WORKING SPACE SHALL BE PROVIDED AND MAINTAINED ABOUT ALL ELECTRICAL EQUIPMENT TO PERMIT READY AND SAFE OPERATION AND MAINTENANCE OF SUCH EQUIPMENT IN ACCORDANCE WITH THE CALIFORNIA ELECTRICAL CODE AND THE MANUFACTURER'S INSTRUCTIONS. ·ELECTROCHEMICAL ESS SHALL BE SEGREGATED INTO GROUPS NOT EXCEEDING 80 KWH PER CFC 127.5.1 AND UL9540A REPORT. EACH GROUP SHALL BE SEPARATED A MINIMUM OF 3 FEET (914 MM) FROM OTHER GROUPS AND FROM WALLS IN THE STORAGE ROOM OR AREA. THE STORAGE ARRANGEMENTS SHALL COMPLY WITH CHAPTER 10. ·AREAS WITHIN 10 FEET (3048 MM) ON EACH SIDE OF OUTDOOR ESS SHALL BE CLEARED OF COMBUSTIBLE VEGETATION AND OTHER COMBUSTIBLE GROWTH. SINGLE SPECIMENS OF TREES, SHRUBBERY OR CULTIVATED GROUND COVER SUCH AS GREEN GRASS, IVY, SUCCULENTS OR SIMILAR PLANTS USED AS GROUND COVER SHALL BE PERMITTED TO BE EXEMPT PROVIDED THAT THEY DO NOT FORM A MEANS OF READILY TRANSMITTING FIRE. ·OUTDOOR INSTALLATIONS SHALL BE IN ACCORDANCE WITH SECTIONS 1207.8.1 THROUGH 1207.8.3. EXTERIOR WALL INSTALLATIONS FOR INDIVIDUAL ESS UNITS ARE 9.7 KWH AND DO NOT EXCEED 20 KWH. ESS OUTDOOR INSTALLATION SHALL BE IN ACCORDANCE WITH SECTION 1207.8.4. ··THE MAXIMUM ENERGY CAPACITY OF INDIVIDUAL ESS UNITS SHALL NOT EXCEED 20 KWH. ··THE ESS SHALL COMPLY WITH APPLICABLE REQUIREMENTS IN SECTION 1207. ··THE ESS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND THEIR LISTING. ··INDIVIDUAL ESS UNITS SHALL BE SEPARATED FROM EACH OTHER BY AT LEAST 8" PER MANUFACTURER INSTRUCTIONS AND UL9540A REPORT ·THE ESS SHALL BE SEPARATED FROM DOORS, WINDOWS, OPERABLE OPENINGS INTO BUILDINGS OR HVAC INLETS BY AT LEAST 3 FEET PER UL9540A REPORT ·ESS LOCATED OUTDOORS SHALL BE SEPARATED BY A MINIMUM OF 10 FEET (3048 MM) FROM EXPOSURES LISTED ON CFC 1207.8.3. 1'1' 4" 1'1'1' D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG ELECTRICAL PLAN VIEWS CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH E202 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #ESTAMP (N) PV POINT OF INTERCONNECTION (POI-7) (N) PV PRODUCTION METER SOCKET 1425 S MINNIE ST UNIT# MTR01 PV PRODUCTION METER REFERENCE METER NUMBER: 222013-124043 (N) UTILITY AC DISCONNECT (ACDS-7.1) (N) MAINTENANCE AC DISCONNECT (ACDS-7.2) (N) AC LOAD CENTER (LC-7.1) (N) PV INVERTER AND ESS AC DISCONNECT (INV-7.1) (N) PV INVERTER AND ESS AC DISCONNECT (INV-7.2) E EQUIPMENT PLAN - POI-7 1425 MINNIE ST SCALE: 3/16" = 1'-0" (N) 58.2 kWh ESS GROUP OF (6) SOLAREDGE BAT-10K1P BATTERIES WALL MOUNTED (EACH BATTERY 9.7KWh) 1425 MINNIE ST 1207.8.3 1207.4.2 & 110.26(A)(1) WORKING CLEARANCE 1429 MINNIE ST F ESS ELEVATION - POI-7 1425 MINNIE ST SCALE: 3/8" = 1'-0" 1425 MINNIE ST (N) AC LOAD CENTER (LC-7.1) (N) PV INVERTER AND ESS AC DISCONNECT (INV-7.1) (N) PV INVERTER AND ESS AC DISCONNECT (INV-7.2) (N) 58.2 kWh ESS GROUP OF (6) SOLAREDGE BAT-10K1P BATTERIES WALL MOUNTED 3'-6"11'-10" 35'-11" DISTANCE BETWEEN BUILDIGNS WILSHIRE MINNIE 1425 S MINNIE ST UNIT# MTR01 APN: 014-251-50 DEVELOPER: C&C DEVELOPMENT 11 ' - 0 " 10 ' - 1 " LEGEND STRING PATH GENERAL NOTES ·FIELD VERIFY ALL MEASUREMENTS ·SEE SHEET E-100 FOR LEGEND OF SYMBOLS STRING ID. X INVERTER ID. # INTERCONNECTION ID. # INCREMENT COUNT 1.1B.A # 1209 E WILSHIRE AVE 1213 E WILSHIRE AVE 1.1.A 2 3 4 5 6 7 8 9 10 11 12 13 1.1.A 1.1.B 2 3 4 5 6 7 8 9 10 11 12 13 1. 1 . B 1. 1 . C 2 3 4 5 6 7 8 9 10 11 12 13 1. 1 . C 1.2.A 2 3 4 5 6 7 8 9 10 11 12 13 1.2.A 1.2.B 2 3 4 5 6 7 8 9 10 11 12 13 1. 2 . B 1. 2 . C 2 3 4 5 6 7 8 9 10 11 12 13 1. 2 . C RB03 TL: 5° AZ: 270° RB04 TL: 5° AZ: 90° RB05 TL: 5° AZ: 270° RB06 TL: 5° AZ: 90° 1201 E WILSHIRE AVE 1.3.A 2 3 4 5 6 7 8 9 10 11 1.3.A 1.3.B 2 3 4 5 6 7 8 9 10 11 1. 3 . B 1. 4 . A 2 3 4 5 6 7 8 9 10 11 1. 4 . A 1. 4 . B 2 3 4 5 6 7 8 9 10 11 1. 4 . B RB01 TL: 5° AZ: 270° RB02 TL: 5° AZ: 90° AVE UNIT# ELE01AVE UNIT# ELE01 PL D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG ELECTRICAL STRINGING CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH E300 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #ESTAMP SCALE: 1/8" = 1'-0" ADDRESSES 1201,1209 & 1213 STRINGING • POI-1A PV INVERTERS INTERCONNECTION LOCATION (1209 WILSHIRE AVE) BESS LOCATION POI-1 MODULE ALLOCATION STR-A STR-B STR-C UNIT INVERTER MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM] MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM] MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM] INV-1.1 SOLAREDGE SE11400H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM] Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RB03 [5°, 270°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (7) RB03 [5°, 270°]; (7) RB04 [5°, 90°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RB04 [5°, 90°]; INV-1.2 SOLAREDGE SE11400H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM] Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RB05 [5°, 270°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (3) RB05 [5°, 270°]; (11) RB06 [5°, 90°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RB06 [5°, 90°]; INV-1.3 SOLAREDGE SE7600H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM] Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RB01 [5°, 270°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (8) RB01 [5°, 270°]; (4) RB02 [5°, 90°]; INV-1.4 SOLAREDGE SE7600H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM] Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RB02 [5°, 90°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RB02 [5°, 90°]; SITE PLAN KEY E302 E303 E301 E300 WILSHIRE MINNIE 1209 E WILSHIRE AVE UNIT# MTR02 1209 3/4 E WILSHIRE AVE UNIT# ELE01 APN: 014-251-49 DEVELOPER: C&C DEVELOPMENT LEGEND STRING PATH GENERAL NOTES ·FIELD VERIFY ALL MEASUREMENTS ·SEE SHEET E-100 FOR LEGEND OF SYMBOLS STRING ID. X INVERTER ID. # INTERCONNECTION ID. # INCREMENT COUNT 1.1B.A # 1221 E WILSHIRE AVE 1225 E WILSHIRE AVE 2.1.A 2 3 4 5 6 7 8 9 10 11 12 13 2.1.A 2.1.B 2 3 4 5 6 7 8 9 10 11 12 13 2. 1 . B 2. 1 . C 2 3 4 5 6 7 8 9 10 11 12 13 2. 1 . C 2.2.A 2 3 4 5 6 7 8 9 10 11 12 2.2.A 2.2.B 2 3 4 5 6 7 8 9 10 11 2.2.B 2.2.C 2 3 4 5 6 7 8 9 10 11 2. 2 . C 2. 3 . A 2 3 4 5 6 7 8 9 10 11 12 2. 3 . A 2. 3 . B 2 3 4 5 6 7 8 9 10 11 2. 3 . B 2. 3 . C 2 3 4 5 6 7 8 9 10 11 2. 3 . C RB07 TL: 5° AZ: 270° RB08 TL: 5° AZ: 90° RF01 TL: 10° AZ: 270° RF02 TL: 10° AZ: 90° 1225 E WILSHIRE AVE 1229 E WILSHIRE AVE 1401 S MINNIE ST 1235 E WILSHIRE AVE 3.1.A 2 3 4 5 6 7 8 9 10 11 3.1.A 3.1.B 2 3 4 5 6 7 8 9 10 11 3.1.B 3.1.C 2 3 4 5 6 7 8 9 10 11 3.1.C 3.2.A 2 3 4 5 6 7 8 9 10 11 3. 2 . A 3. 2 . B 2 3 4 5 6 7 8 9 10 11 3. 2 . B 3. 2 . C 2 3 4 5 6 7 8 9 10 11 3. 2 . C 3. 3 . A 2 3 4 5 6 7 8 9 10 11 12 13 3. 3 . A 3. 3 . B 2 3 4 5 6 7 8 9 10 11 12 13 3. 3 . B 3. 3 . C 2 3 4 5 6 7 8 9 10 11 12 13 3. 3 . C 11 12 13 4.1. A 4.1. B 2 3 4 5 6 7 8 9 10 11 12 13 4.1. B 4.1. C 2 3 4 5 6 7 8 9 10 11 12 13 4.2. A 4.2. B 2 3 4 5 6 7 8 9 10 RB10 TL: 5° AZ: 142° RF03 TL: 10° AZ: 270° RF04 TL: 10° AZ: 90° RF05 TL: 19° AZ: 270° RF06 TL: 19° AZ: 90° RF08 TL: 15° AZ: 270° 1229 3/4 E WILSHIRE AVE UNIT# ELE01 PL D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG ELECTRICAL STRINGING CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH E301 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #ESTAMP SCALE: 1/8" = 1'-0" ADDRESSES 1221,1225 STRINGING • POI-2A SCALE: 1/8" = 1'-0" ADDRESSES 1229,1235 STRINGING • POI-3B BESS LOCATION INTERCONNECTION LOCATION (1221 E WILSHIRE AVE) PV INVERTERS INTERCONNECTION LOCATION (1229 E WILSHIRE AVE) BESS LOCATION PV INVERTERS POI-2 MODULE ALLOCATION STR-A STR-B STR-C UNIT INVERTER MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM] MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM] MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM] INV-2.1 SOLAREDGE SE11400H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM] Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RB07 [5°, 270°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (11) RB07 [5°, 270°]; (3) RB08 [5°, 90°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RB08 [5°, 90°]; INV-2.2 SOLAREDGE SE11400H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM] Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]13 U650 (13) RF01 [10°, 270°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RF01 [10°, 270°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (7) RF01 [10°, 270°]; (5) RF02 [10°, 90°]; INV-2.3 SOLAREDGE SE11400H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM] Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]13 U650 (13) RF02 [10°, 90°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RF02 [10°, 90°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RF02 [10°, 90°]; POI-3 MODULE ALLOCATION STR-A STR-B STR-C UNIT INVERTER MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM] MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM] MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM] INV-3.1 SOLAREDGE SE11400H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM] Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RF03 [10°, 270°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RF03 [10°, 270°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RF03 [10°, 270°]; INV-3.2 SOLAREDGE SE11400H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM] Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (4) RF03 [10°, 270°]; (8) RF04 [10°, 90°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RF04 [10°, 90°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RF04 [10°, 90°]; INV-3.3 SOLAREDGE SE11400H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM] Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RF05 [19°, 270°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (6) RF05 [19°, 270°]; (8) RF06 [19°, 90°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RF06 [19°, 90°]; SITE PLAN KEY E302 E303 E301 E300 WILSHIRE MINNIE 1221 E WILSHIRE AVE UNIT# MTR02 1221 3/4 E WILSHIRE AVE UNIT# ELE01 1229 E WILSHIRE AVE UNIT# MTR02 1229 3/4 E WILSHIRE AVE UNIT# ELE01 APN: 014-251-49 DEVELOPER: C&C DEVELOPMENT LEGEND STRING PATH GENERAL NOTES ·FIELD VERIFY ALL MEASUREMENTS ·SEE SHEET E-100 FOR LEGEND OF SYMBOLS STRING ID. X INVERTER ID. # INTERCONNECTION ID. # INCREMENT COUNT 1.1B.A # 1233 E WILSHIRE AVE 1401 S MINNIE ST 1235 E WILSHIRE AVE 2 3 4 5 6 7 8 9 10 11 12 13 3. 3 . A 3. 3 . B 4 5 6 7 8 9 10 11 12 13 3. 3 . B 3. 3 . C 2 3 4 5 6 7 8 9 10 11 12 13 3. 3 . C 4.1. A 2 3 4 5 6 7 8 9 10 11 12 13 4.1. A 4.1. B 2 3 4 5 6 7 8 9 10 11 12 13 4.1. B 4.1. C 2 3 4 5 6 7 8 9 10 11 12 13 4.1. C 4.2. A 2 3 4 5 6 7 8 9 10 11 12 13 4.2. A 4.2. B 2 3 4 5 6 7 8 9 10 11 12 13 4.2. B RB09 TL: 5° AZ: 322° RB10 TL: 5° AZ: 142° 1401 S MINNIE ST 5.1.A 2 3 4 5 6 7 8 9 10 11 12 5.1.A 5.1.B 2 3 4 5 67891011125.1.B5.1.C2345678910115.1.C5.2.A2 3 4 5 6 7 8 9 10 11 12 5.2.A 5.2.B 2 3 4 5 6 7 8910115.2.B 5.3.A2345678910 11 12 5.3.A 5.3.B 2 3 4 5 6 7 8 9 10 5. 3 . B RB10 TL: 5° AZ: 142° RF07 TL: 15° AZ: 0° RF08 TL: 15° AZ: 270° RF09 TL: 15° AZ: 180° RF10 TL: 15° AZ: 90° PL D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG ELECTRICAL STRINGING CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH E302 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #ESTAMP SCALE: 3/32" = 1'-0" ADDRESS 1233 STRINGING • POI-4A SCALE: 3/32" = 1'-0" ADDRESS 1401 STRINGING • POI-5B BESS LOCATION (ON CONCRETE PAD) INTERCONNECTION LOCATION (1233 E WILSHIRE AVE) PV INVERTERS (RACK ON CONCRETE PAD) INTERCONNECTION LOCATION (1401 S MINNIE ST) BESS LOCATION PV INVERTERS POI-4 MODULE ALLOCATION STR-A STR-B STR-C UNIT INVERTER MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM] MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM] MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM] INV-4.1 SOLAREDGE SE11400H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM] Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RB09 [5°, 322°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RB09 [5°, 322°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RB09 [5°, 322°]; INV-4.2 SOLAREDGE SE7600H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM] Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (2) RB09 [5°, 322°]; (12) RB10 [5°, 142°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RB10 [5°, 142°]; POI-5 MODULE ALLOCATION STR-A STR-B STR-C UNIT INVERTER MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM] MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM] MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM] INV-5.1 SOLAREDGE SE11400H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM] Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]13 U650 (13) RF07 [15°, 0°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]13 U650 (13) RF07 [15°, 0°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RF07 [15°, 0°]; INV-5.2 SOLAREDGE SE7600H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM] Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]13 U650 (1) RF07 [15°, 0°]; (5) RF08 [15°, 270°]; (7) RF09 [15°, 180°]; Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RF09 [15°, 180°]; INV-5.3 SOLAREDGE SE7600H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM] Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]13 U650 (13) RF09 [15°, 180°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]11 U650 (7) RF09 [15°, 180°]; (4) RF10 [15°, 90°]; SITE PLAN KEY E302 E303 E301 E300 WILSHIRE MINNIE 1233 E WILSHIRE AVE UNIT# MTR01 1401 S MINNIE ST UNIT# MTR01 APN: 014-251-49 DEVELOPER: C&C DEVELOPMENT LEGEND STRING PATH GENERAL NOTES ·FIELD VERIFY ALL MEASUREMENTS ·SEE SHEET E-100 FOR LEGEND OF SYMBOLS STRING ID. X INVERTER ID. # INTERCONNECTION ID. # INCREMENT COUNT 1.1B.A # 6.1.A 2 3 4 5 6 7 8 9 10 11 12 136.1.A6.1.B234 5 6 7 8 9 10 11 12 13 6.1.B 6.2.A 2 3 4 5 6 7 8 9 10 11 12 13 6.2.A 6.2.B 2 3 4 5 6 7 8 9 10 11 12 13 6.2.B RB11 TL: 5° AZ: 180° RB12 TL: 5° AZ: 180° RB13 TL: 5° AZ: 270° RB14 TL: 5° AZ: 90° 1403 S MINNIE ST 1425 S MINNIE ST 7.1.A2345678910117.1.A7.1.B234 5 6 7 8 9 10 7.1.B 7.1.C 2 3 4 5 6 7 8 9 10 7.1.C 7.2.A 2 3 4 5 6 7 89 10 11 7. 2 . A 7. 2 . B 2 3 4 5 6 7 89 10 7. 2 . B RF11 TL: 10° AZ: 0° RF12 TL: 10° AZ: 180° RF13 TL: 10° AZ: 270° RF14 TL: 10° AZ: 90° PL D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG ELECTRICAL STRINGING CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH E303 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #ESTAMP SCALE: 3/32" = 1'-0" ADDRESS 1403 STRINGING • POI-6 A BESS LOCATION INTERCONNECTION LOCATION (1403 S MINNIE ST) PV INVERTERS SCALE: 3/32" = 1'-0" ADDRESS 1425 STRINGING • POI-7A POI-6 MODULE ALLOCATION STR-A STR-B UNIT INVERTER MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM]MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM] INV-6.1 SOLAREDGE SE7600H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM] Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RB11 [5°, 180°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (4) RB11 [5°, 180°]; (10) RB12 [5°, 180°]; INV-6.2 SOLAREDGE SE7600H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM] Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (5) RB12 [5°, 180°]; (6) RB13 [5°, 270°]; (3) RB14 [5°, 90°]; Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RB14 [5°, 90°]; POI-7 MODULE ALLOCATION STR-A STR-B STR-C UNIT INVERTER MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM] MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM] MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM] INV-7.1 SOLAREDGE SE11400H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM] Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RF11 [10°, 0°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]11 U650 (4) RF11 [10°, 0°]; (7) RF12 [10°, 180°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]11 U650 (11) RF12 [10°, 180°]; INV-7.2 SOLAREDGE SE7600H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM] Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (5) RF12 [10°, 180°]; (7) RF13 [10°, 270°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]11 U650 (1) RF13 [10°, 270°]; (10) RF14 [10°, 90°]; SITE PLAN KEY E302 E303 E301 E300 BESS LOCATION PV INVERTERS INTERCONNECTION LOCATION (1425 S MINNIE ST) WILSHIRE MINNIE 1403 S MINNIE ST UNIT# MTR01 1425 S MINNIE ST UNIT# MTR01 APN: 014-251-49 / 014-251-50 DEVELOPER: C&C DEVELOPMENT LEGEND STRING PATH GENERAL NOTES ·FIELD VERIFY ALL MEASUREMENTS ·SEE SHEET E-100 FOR LEGEND OF SYMBOLS STRING ID. X INVERTER ID. # INTERCONNECTION ID. # INCREMENT COUNT 1.1B.A # BLDG 1425 BLDG 1429 RF11 TL: 10° AZ: 0° RF12 TL: 10° AZ: 180°RF13 TL: 10° AZ: 270° RF14 TL: 10° AZ: 90° RF15 TL: 10° AZ: 270° RF16 TL: 10° AZ: 90°RF17 TL: 10° AZ: 0° RF18 TL: 10° AZ: 180° 10.1.A 2 3 4 5678910 11 12 13 10.1.A 10.1.B 2 3 4 5 6 7 8 9 10 11121310.1.B10.1.C234567 8 9 10 11 12 13 10.1.C 10.2.A23 4 5 6 7 10.2.A 10 . 2 . B 2 3 4 5 6 7 10 . 2 . B 10 . 2 . C 2 3 4 5 6 7 8 9 10 . 2 . C 11.1.A 2 3 4 5 6 7 8910111211.1.A 11.1.B234567 8 9 10 11 12 11.1.B 11.1.C234567 8 9 10 11 11.1.C 11.2.A 2 3 4 5 6 7 11.2.A 11 . 2 . B 2 3 4 5 6 7 11 . 2 . B 11 . 2 . C 2 3 4 5 6 7 8 9 11 . 2 . C C:\USERS\EMILIANO.MORALES\DESKTOP\WORKING PROJECTS\1235_WILSHIRE_MINNIE\CD100\WILSHIRE MINNIE_WORKINGDOCS_V0\WILSHIRE MINNIE.DWG ELECTRICAL STRINGING CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 PROJECT DETAILS: PV SYSTEM: ·355.88 kW DC ·250.8 kW AC ·331.612 CEC AC ENERGY STORAGE: ·243.2 kW AC ·756.6 kWH E304 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM ORIGINAL CONTRACT NUMBER: 3003197607 PJT #: PROP-001235 SCALE: 1/8" = 1'-0" BLDG 1425,1429 STRINGING • POI-10 & POI-11A INTERCONNECTION LOCATION BESS LOCATION PV INVERTER AND ESS AC DISCONNECT POI-10 MODULE ALLOCATION STR-A STR-B STR-C UNIT INVERTER MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM] MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM] MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM] INV-10.1 SOLAREDGE SE11400H-US HOME HUB [SI1-SB] Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RF11 [10°, 0°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (10) RF11 [10°, 0°]; (4) RF12 [10°, 180°]; Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RF12 [10°, 180°]; INV-10.2 SOLAREDGE SE7600H-US HOME HUB [SI1-SB] Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]8 U650 (8) RF12 [10°, 180°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]8 U650 (8) RF13 [10°, 270°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]10 U650 (10) RF14 [10°, 90°]; POI-11 MODULE ALLOCATION STR-A STR-B STR-C UNIT INVERTER MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM] MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM] MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM] INV-11.1 SOLAREDGE SE11400H-US HOME HUB [SI1-SB] Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]13 U650 (13) RF18 [10°, 180°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]13 U650 (13) RF18 [10°, 180°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RF17 [10°, 0°]; INV-11.2 SOLAREDGE SE7600H-US HOME HUB [SI1-SB] Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]8 U650 (8) RF17 [10°, 0°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]8 U650 (8) RF15 [10°, 270°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]10 U650 (10) RF16 [10°, 90°]; STRUT CONDUIT CLAMP 12 GA GALVANIZED STEEL SIZED AS APPROPRIATE 1-5/8" STRUT CHANNEL 12 GA, HDG NOTE: ALL HOLES FOR CONDUIT SHALL BE PROVIDED WITH CONDUIT FITTINGS HAVING AN ENVIRONMENTAL RATING APPROVED TO MAINTAIN NEMA 3R ENCLOSURE RATING (UL508A, TABLE 19.2). IN GENERAL COMPONENTS MARKED "WEATHERPROOF" OR "RAINPROOF" SHALL BE INSTALLED ONLY BELOW THE LOWEST UNINSULATED LIVE PARTS WITHIN THE ENCLOSURE. CONDUIT OPENINGS ABOVE THE LOWEST UNINSULATED LIVE PARTS SHALL BE PROVIDED WITH CONDUIT FITTINGS MARKED "WET LOCATION" OR "RAINTIGHT". WOOD: MIN. 2" EMBED W/ 3/8" LAG TO (E) STUD OR 4"xBLOCK W/ A34 EA. END T&B MASONRY: USE ICC-APPROVED MASONRY ANCHORS STEEL: USE SELF-DRILLING, SELF-TAPPING SCREWS OPTION 1 OPTION 2 2-HOLE 12 GA GALV STEEL STRAP NTS CONDUIT SUPPORT - WALLC 24 " S U G G . D E P T H 18 " M I N . C O V E R 8" (E) ASPHALT/CONCRETE (N) FINISHED GRADE, REPAIR CAP TO MATCH EXISTING. RED WARNING TAPE W/ TRACE WIRE APPROVED BACKFILL PVC CONDUIT (REFER TO PLANS AND WIRE SCHEDULE FOR ACTUAL NUMBER AND LOCATION OF CONDUITS). 3" MIN. NTS TRENCH THROUGH PAVEMENT NON-TRAFFIC DETAILD USE EXISTING HOLES TO TERMINATE CONDUCTORS, TORQUE PER MANUFACTURER REQUIREMENTS. USE GRADE 5 OR LARGER BOLT. UL LISTED CRIMP RATED FOR 600 VOLTS CRIMPED IN 2 PLACES. USE MANUFACTURER APPROVED CRIMPING DEVICE ONLY AND APPLY ANTIOXIDANT COMPOUND BEFORE CRIMPING. SIDE VIEWFRONT VIEW (E) BUS NOTE: ALUMINUM CONDUCTORS SHALL NOT BE TERMINATED WITH MECHANICAL LUGS. TORQUE MARK BOLT WITH PAINT PEN AFTER TORQUING NUT/BOLT B CONDUCTOR TERMINATION DETAIL NTS CONTINUOUS GROUND STRIP INSULATION AT LUG ENCLOSURE LOCK NUT GROUNDING BUSHING WITH LAY-IN LUG CONDUIT COMPRESSION FITTING NTS CONDUIT GROUNDING DETAILA 30 " S U G G . D E P T H 24 " M I N . C O V E R 8" (E) ASPHALT/CONCRETE (N) FINISHED GRADE, REPAIR CAP TO MATCH EXISTING. RED WARNING TAPE W/ TRACE WIRE APPROVED BACKFILL PVC CONDUIT (REFER TO PLANS AND WIRE SCHEDULE FOR ACTUAL NUMBER AND LOCATION OF CONDUITS). 3" MIN. E TRENCH THROUGH PAVEMENT TRAFFIC DETAIL NTS 4'-0" MIN (N) PVC SWEEPER BORE PIT VARIES NOTE: 4' BORE DEPTH TO BE MAINTAINED EXCEPT WHERE ELEVATION CHANGES ARE REQUIRED TO AVOID OBSTACLES RECEIVING PIT NTSFHORIZONTAL BORE DETAIL NOTE: ACCESSIBLE MEANS EXTERNAL TO ENCLOSURES FOR CONNECTING INTERSYSTEM BONDING AND GROUNDING CONDUCTORS SHALL BE PROVIDED. SEE NEC 250.94. SERVICE DISCONNECT 1 OF 2 WHERE NEUTRAL TERMINAL BUS IS INSULATED FROM THE ENCLOSURE, INSTALL A MAIN BONDING JUMPER OR SCREW WITH A GREEN SEE NEC 250.8, 250.28. NEUTRAL DISCONNECT MEANS. SEE NEC 230.75. WHERE SERVICE ENTRANCE RACEWAY IS INSTALLED WITH LOCKNUTS, INSTALL A GROUND BUSHING OR DEVICE AND BOND TO THE ENCLOSURE. SEE NEC 250.92 (B) (4). GROUNDING ELECTRODE SYSTEM – SEE NEC 250.50. IF METALLIC CONDUIT, BONDING REQUIRED (BOTH ENDS) SEE NEC 250.92. GROUNDING ELECTRODE CONDUCTOR – SEE NEC 250.62 FOR MATERIAL, NEC 250.64 FOR INSTALLATION, AND NEC 250.66 FOR SIZE. CONNECTION TO ELECTRODE – CONNECT GROUNDING ELECTRODE CONDUCTOR TO GROUNDING ELECTRODE WITH LISTED GROUND SEE NEC 250.70. BONDING JUMPER SEE NEC 250.92 (A) (2). FOR SIZES, SEE NEC 250.102 (C). LAY IN LUG. WHERE LUG IS INSULATED FROM ENCLOSURE, INSTALL A BONDING JUMPER OR SCREW. GROUNDED (NEUTRAL) SERVICE ENTRANCE CONDUCTOR FROM PV SYSTEM SERVICE DISCONNECT 2 OF 2 METER ENCLOSURE G METER GROUNDING DETAIL NTS D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG ELECTRICAL DETAILS CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH E400 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #ESTAMP WILSHIRE MINNIE 1209 E WILSHIRE AVE UNIT# MTR02 1209 3/4 E WILSHIRE AVE UNIT# ELE01 1221 E WILSHIRE AVE UNIT# MTR02 1221 3/4 E WILSHIRE AVE UNIT# ELE01 1229 E WILSHIRE AVE UNIT# MTR02 1229 3/4 E WILSHIRE AVE UNIT# ELE01 1233 E WILSHIRE AVE UNIT# MTR01 1401 S MINNIE ST UNIT# MTR01 1403 S MINNIE ST UNIT# MTR01 1425 S MINNIE ST UNIT# MTR01 APN: 014-251-49 / 014-251-50 DEVELOPER: C&C DEVELOPMENT RAIL CHANNEL NUT MODULE FRAME MID CLAMP ASSEMBLY SS BONDING PIN NOTE: 1.ADJUSTABLE END CLAMPS USE SAME BONDING PIN DESIGN TO BOND MODULES TO RAIL C MID CLAMP ASSEMBLY NTS NOTES: 1.INSTALL EXPANSION COUPLING EVERY 100' OF STRAIGHT CONDUIT RUN 2.IF EXPANSION COUPLINGS ARE INSTALLED AT LESS THAN 100'.THE DISTANCES OF EXPANSION/CONTRACTION SHALL BE ADJUSTED PROPORTIONALLY. 3.IF EXPANSION JOINT IS NOT PROVIDED WITH INTERNAL BONDING JUMBER, AN EXTERNAL BONDING JUMPER MUST BE INSTALLED. INSTALL EXPANSION COUPLINGS SO THAT THE LENGTH CHANGE FOR CONTINUOUS CONDUIT DOES NOT EXCEED 1/4". SEE NEC 352.44 FOR STEEL CONDUIT, MULTIPLY THE EXPANSIONS LISTED IN TABLE 352.44 BY 0.2. SEE NEC 300.7 0°F - EXTEND 3/8" BEYOND CENTER 60°F - CENTERED 30°F - EXTEND 3/16" BEYOND CENTER 90°F - EXTEND 3/16" BEYOND CENTER 120°F - EXTEND 3/8" BEYOND CENTER CONDUIT TYPE COEFFICIENT (IN./IN/°F)TEMP °F EXPANSION/ 100FT (IN) STEEL 6.5 X 10-6 120 0.94 PVC 3.4 X 10-5 120 4.87 B CONDUIT THERMAL EXPANSION DETAIL NTS D SNAPNRACK ULTRA RAIL BONDING SPLICE NTS RAIL GAP RANGE THERMAL EXPANSION GAP: 1/8" - 1/4" RAIL EDGE MUST NOT PASS THE BONDING CLIP EDGE, AS SHOWN. SPLICE ALIGNMENT LIMITS SNAPNRACK, UR-40/UR-45 RAIL TORQUE ALL FASTENERS TO THE SPECIFIED VALUES PRIOR TO INSTALLING PV MODULES SNAPNRACK, ULTRA RAIL SPLICE SNAPNRACK, UR-40/UR-45 SPLICE INSALLED SNAPNRACK BONDING CLIP, TYPE 2 FOR BONDING ACROSS RAILS NOTE: 1.ALL HARDWARE IS INCLUDED FROM MANUFACTURER 2.REFER TO SNAPNRACK INSTALLATION MANUAL FOR 5/16"Ø HARDWARE TORQUE SPEC 3.SPLICE POSITIONING: 3.1.APPROVED - ANYWHERE ALONG RAIL SPAN BETWEEN TWO ROOF ATTACMENTS 3.2.NOT APPROVED - RAIL OVERHANGS / CANTILEVERS 4.USE OF THE UR-40/UR-45 SPLICE WITH UR-60 RAIL IS PROHIBITED SNAPNRACK, UR-40 RAIL 1 3/4" 1 5/8" 1 1/2" 1 1/2" SNAPNRACK, UR-45 RAIL E SNAPNRACK OMNILUG NTS OMNILUG GROUND LUG ON ULTRA RAIL OMNILUG MPLE ATTACHMENT ON ULTRA RAIL GROUND LUG NOTE: 1.PLACE THE GROUNDING CONDUCTOR INTO THE SLOT ON THE BONDING BRACKET UNDERNEATH THE CONICAL WASHER ON THE SEMS BOLT. 1.1.GROUNDING CONDUCTOR MUST EXTEND BEYOND THE ENTIRE CONICAL WASHER TO ASSURE PROPER BONDING. 1.2.TIGHTEN THE MOUNTING BOLT TO 10.8 LB-FT. 2.OPTIMIZERS AND MICROINVERTERS SHOULD ALWAYS BE INSTALLED PER SPECIFIC MANUFACTURER'S INSTRUCTION. MLPE NOTE: 1.PLACE THE MOUNTING PLATE CHASSIS OF THE MLPE DEVICE ON THE BONDING BRACKET UNDERNEATH THE CONICAL WASHER ON THE SEMS BOLT. 2.TIGHTEN THE MOUNTING BOLT TO 10.8 LB-FT. 2 1 3 EXPLODED VIEW ITEM QTY 1 2 3 PARTS LIST DESCRIPTION 1 SNAPNRACK, OMNILUG, BONDING BRACKET, SS 1 SEMS SCREW, HEX, 5-16IN-18 X 1-1-4IN, 7-8 OD CONICAL WSH, TOOTH, SS 1 SNAPNRACK CHANNEL NUT 5-16IN-18 TOP VIEW SIDE VIEW 1.78 1.78 0.29 0.41 1.53 G SNR GROUND PATH DETAIL - SOLAREDGE NTS X M M M X TO EGC X M M M X U M U U U TO EGC U M U U U GROUND PATH RAIL RAIL SPLICE MOUNT EQUIPMENT GROUNDING CONDUCTOR GROUND LUG SOLAREDGE OPTIMIZER M MODULE CLAMP M = MIDCLAMP X = X-END CLAMP U = UNIVERSAL END CLAMP F SNAPNRACK FRAME MLPE ATTACHMENT NTS .66 .14 R.12 .63 .30 2.24 1.50 .50 .95 SOLAR MODULE SNR MLPE FRAME ATTACHMENT MODULE LEVEL POWER ELECTRONIC SOLAR MODULE FRAME MODULE FRAME MLPE INSTALLATION VIEW INTEGRATED SMART CLIP MODULE FRAME MLPE TOP VIEW MODULE FRAME MLPE SIDE VIEW SCE BARRIERS SCE ESR-3: 16.11 PROTECTIVE BARRIERS (POSTS/ BOLLARDS) FOR SERVICE EQUIPMENT (1-26-2024)A NOTES: ·MAINTAIN A MINIMUM OF 3' CLEAR AND LEVEL WORKING SPACE IN FRONT OF ALL THE SERVICE EQUIPMENT ENCLOSURES. ·90 DEG MIN. OPENING FOR SERVICE EQUIPMENT DOORS/ PANELS. ·4" GALVANIZED STEEL PIPE (1/4" MIN. WALL) FILLED WITH CONCRETE AND PAINTED "CAUTION YELLOW." ·CONCRETE ENCASEMENT 6" MIN. IN STABLE SOIL, 12" MIN. IN SANDY OR UNSTABLE SOIL. ·BARRIERS MUST BE INSTALLED IN LINE WITH EACH END OF SERVICE EQUIPMENT. ·4'-6" MIN. DISTANCE BETWEEN CENTER OF BARRIERS. 2'-6" CONCRETE 6" or 12" FINAL GRADE CONCRETE FILLED CONCRETE CAP 2'-6" 5'-0" 4'-6" MAX. 3'-0" MIN. PULL CAN / SECTION OR METERS 4'-6" MAX. NON-REMOVABLE BARRIER POST DETAILPLAN VIEW 3" PARKING SPACES OR VEHICULAR TRAFFIC 4'-6" MAX. 3'-0" MIN. 4'-6" MAX. 3'-0" MIN. 4'-6" MAX. D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG ELECTRICAL DETAILS CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH E401 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #ESTAMP WILSHIRE MINNIE 1209 E WILSHIRE AVE UNIT# MTR02 1209 3/4 E WILSHIRE AVE UNIT# ELE01 1221 E WILSHIRE AVE UNIT# MTR02 1221 3/4 E WILSHIRE AVE UNIT# ELE01 1229 E WILSHIRE AVE UNIT# MTR02 1229 3/4 E WILSHIRE AVE UNIT# ELE01 1233 E WILSHIRE AVE UNIT# MTR01 1401 S MINNIE ST UNIT# MTR01 1403 S MINNIE ST UNIT# MTR01 1425 S MINNIE ST UNIT# MTR01 APN: 014-251-49 / 014-251-50 DEVELOPER: C&C DEVELOPMENT GENERAL ELECTRICAL NOTES MODULE CHARACTERISTICS OPTIMIZER CHARACTERISTICS SINGLE LINE DIAGRAM LEGEND CURRENT TRANSFORMER (DOT INDICATES DIRECTION) METER CIRCUIT BREAKER SWITCH PV MODULE FUSE INVERTER~ -- M CELLULAR ANTENNA DC COMBINER TRANSFORMER BATTERY MODULE A B TRANSFER SWITCH (ATS/ MTS) JUNCTION BOX +- INTERCONNECTION NOTES INTERCONNECTION NOTES ·SUPPLY SIDE INTERCONNECTIONS SHALL COMPLY WITH ART. 705.11 AND ART 230 FOR THE INSTALLATION OF AN ADDITIONAL SERVICE ENTRANCE ·THE OVERCURRENT PROTECTION DEVICE ON THE SUPPLY SIDE OF THE SERVICE DISCONNECTING MEANS SHALL BE WITHIN 10 FEET OF THE INTERCONNECTION POINT UNLESS CABLE LIMITERS OR CURRENT-LIMITED CIRCUIT BREAKERS ARE INSTALLED ON EACH UNGROUNDED CONDUCTOR AT THE POINT OF INTERCONNECTION PER ART. 705.11(C). THIS OVERCURRENT DEVICE MUST BE SIZED FOR THE SHORT-CIRCUIT CURRENT SUPPLIED FROM THE PRIMARY SOURCE(S) OF ELECTRICITY. ·SUPPLY SIDE INTERCONNECTIONS SHALL BE MADE IN ACCORDANCE WITH THE EQUIPMENT MANUFACTURER'S INSTRUCTIONS AND SHALL NOT INVALIDATE THE NRTL LISTING OF THE EQUIPMENT. ·RMC OR SCH 80 PVC TYPE CONDUIT SHALL BE USED TO ENCLOSE NEW SERVICE CONDUCTORS USED FOR A SUPPLY SIDE INTERCONNECTION. ·NEW SERVICE CONDUCTORS USED FOR SUPPLY SIDE INTERCONNECTIONS SHALL BE INSTALLED IN A SEPARATE RACEWAY FROM ANY LOAD SIDE CONDUCTORS WITHIN THE MAIN SWITCHBOARD PER NEC 230.7. GENERAL NOTES ·ALL ELECTRICAL WORK SHALL COMPLY WITH THE NEC 2020 CODE AS AMENDED BY APPLICABLE STATE AND LOCAL CODES. ·EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM PER ART 210.5. ·BRANCH CIRCUITS SUPPLIED FROM DC SYSTEMS MUST BE IDENTIFIED IN COMPLIANCE WITH ART. 210.5(C)(2) WHERE DC POSITIVE (+) IS RED/ RED-STRIPED AND DC NEGATIVE (-) IS BLACK/BLACK-STRIPED. ·ALL EQUIPMENT SHALL BE LISTED BY A NRTL IN COMPLIANCE WITH ART 110.3. ·DC CONDUCTORS INSIDE BUILDING SHALL BE IN METALLIC RACEWAY PER ART 690.31(D). ·ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NRTL LISTING. ·PARALLEL CONDUCTORS SHALL BE INSTALLED PER ART 310.10(G). ·ALL VALUES FOR Imp, Isc AND Vmp ARE PER MANUFACTURER'S LISTED DATA AT STC. MAXIMUM VOLTAGE CALCULATED IN ACCORDANCE WITH ARTICLE NEC 690.7. ·REFER TO CURRENT MANUFACTURER'S PLANNING AND INSTALLATION MANUAL FOR TORQUE SPECS FOR ALL BOLTS AND TERMINAL CONNECTIONS. ·BRANCH CIRCUITS RUN IN OUTDOOR ROOFTOP AMBIENT CONDITIONS SHALL BE INSTALLED > 7/8 INCH ABOVE ROOF SURFACE. ·ALL PV CIRCUITS LOCATED OUTSIDE THE ARRAY BOUNDARY OR MORE THAN 3 FT FROM THE POINT OF ENTRY INSIDE A BUILDING SHALL BE LIMITED TO NOT MORE THAN 30 VOLTS WITHIN 30 SECONDS, CIRCUITS INSIDE THE ARRAY BOUNDARY OR NOT MORE THAN 3 FT FROM THE POINT OF PENETRATION SHALL BE LIMITED TO NOT MORE THAN 80 VOLTS UPON RAPID SHUT-DOWN INITIATION PER 690.12. ·PV SYSTEM SHALL CONTAIN OR INTERACT WITH DEVICES CAPABLE OF DETECTING AND INTERRUPTING ARCING FAULTS WITHIN THE SYSTEM PER 690.11. ·BURIED CONDUCTORS SHALL BE BURIED TO THE MINIMUM DEPTH SPECIFIED IN ART. 300.5 FOR CIRCUITS 1000V AND UNDER AND ART. 300.50 FOR CIRCUITS ABOVE 1000V. ·SPACES ABOUT ELECTRICAL EQUIPMENT 1000V AND UNDER SHALL COMPLY WITH 110.26 AND SPACES ABOUT ELECTRICAL ENCLOSURES ABOUT EQUIPMENT ABOVE 1000V SHALL COMPLY WITH 110.34. ·REFER TO THE CONDUCTOR SCHEDULE FOR THE TYPE OF CONDUCTORS TO BE USED FOR THE LISTED CIRCUITS. ·PV WIRE SHALL BE SECURED USING NON-METALLIC UV-RATED TIE WRAPS. ·ALL LINE SIDE AND LOAD SIDE TERMINATIONS OF ALUMINUM AND COPPER CONDUCTORS SHALL BE MADE WITH HIGH PRESS CRIMP LUGS ON BUSSING UNLESS OTHERWISE NOTED. ·ALL TERMINATIONS OF ALUMINUM CONDUCTORS SHALL BE PROPERLY INSTALLED WITH BEST PRACTICE PROCEDURES THAT INCLUDE BUT NOT LIMITED TO: USE OF TERMINATION EQUIPMENT RATED FOR ALUMINUM AT THE CONDUCTOR TEMPERATURE, CURRENT, AND VOLTAGE; ALLOWANCE FOR MOVEMENT DUE TO THERMAL EXPANSION/CONTRACTION; PROPER COATING OF EXPOSED ALUMINUM WITH ANTI-OXIDIZATION COMPOUND; USE OF CALIBRATED DEVICES TO TORQUE AND MARK TERMINALS TO REQUIRED SETTINGS. ·AT MULTIPLE INVERTERS OUTPUT COMBINER PANEL, TOTAL RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, THE MAIN OVERCURRENT DEVICE MAY BE EXCLUDED ACCORDING TO NEC 705.12 (B)(3)(3). GROUNDING NOTES ·GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVICES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. ·PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM NEC TABLE 250.122. ·METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136. ·EACH MODULE WILL BE GROUNDED USING THE HARDWARE INTEGRATED GROUNDING PINS OR OTHER MEANS APPROVED BY THE MODULE MANUFACTURE AND AHJ. ·THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. ··GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER [NEC 250.119(A)] ·THE AC & DC GEC SHALL BE CONTINUOUS FROM THE INVERTER GROUND BUSBAR TO THE MAIN ELECTRICAL SERVICE GROUNDING ELECTRODE SYSTEM. THE DC GEC SHALL BE ATTACHED TO THE GROUND ELECTRODE USING AN IRREVERSIBLE MEANS AS CALLED OUT IN ART 250.64 AND 690.47. ·PV INVERTER CONTAINS AN INTEGRATED GFDI CIRCUIT. DO NOT BOND THE GROUNDED DC CONDUCTOR TO GROUND EXCEPT THROUGH THE INVERTER GFDI. ·ALL EXPOSED METAL PARTS (MODULE FRAMES, RAIL, PIPE, BOXES, ETC) SHALL BE GROUNDED USING TIN-PLATED COPPER LAY-IN LUGS OR GROUNDING CLIPS LISTED FOR THE PURPOSE. RAIL CLAMPS SHALL BE MADE ELECTRICALLY CONTINUOUS WITH ATTACHED RAIL. ·RACKING SYSTEMS SHALL BE BONDED PER MANUFACTURER'S UL 2703 INSTRUCTIONS. ·MIN #10 BARE COPPER EGC AT SOURCE CIRCUITS SHALL BE ROUTED SECURELY TO MOUNTING HARDWARE IN A MANNER THAT PROTECTS FROM PHYSICAL HARM. #6 BARE COPPER EGC FOR AREAS SUBJECT TO PHYSICAL DAMAGE. ·MODULE FRAMES SHALL BE GROUNDED AT THE LISTED LOCATION PROVIDED BY THE MANUFACTURER OR USING LISTED THIRD-PARTY HARDWARE ONLY IF SPECIFICALLY REFERRED TO IN MANUFACTURER'S INSTRUCTIONS PER UL 1703.INSTALLER SHALL COMPLY WITH MANUFACTURER GROUND IN BONDING REQUIREMENTS ·BOTH ENDS OF ALL METALLIC CONDUIT CONTAINING GROUNDING ELECTRODE CONDUCTORS SHALL BE BONDED PER ART 250.64(E). ·GROUNDING ELECTRODE CONDUCTOR TO BE BONDED TO (E) GROUNDING ELECTRODE PER ART 250.68. ·DC GROUNDING ELECTRODE CONDUCTOR SIZED PER ART 690.47. AC GROUNDING ELECTRODE CONDUCTOR PER 250.66. ·MAIN BONDING JUMPERS AND GROUNDED CONDUCTORS (NEUTRALS) SHALL BE SIZED PER 250.102 UNLESS OTHERWISE ALLOWED TO BE SIZED PER 705.28(C). ·INCREASES IN DC EQUIPMENT GROUNDING CONDUCTOR SIZE TO ADDRESS VOLTAGE CONSIDERATIONS SHALL NOT BE REQUIRED PER ART 690.45. ·INCREASES IN AC EQUIPMENT GROUNDING CONDUCTOR SIZE TO ADDRESS VOLTAGE CONSIDERATIONS SHALL BE REQUIRED PER 250.122(B). ·INSTALLATION SHALL COMPLY WITH ART 250.52, 250.53. ·CIRCUITS OVER 250V SHALL COMPLY WITH ART. 250.97, 250.92(B). SITE TEMPERATURES MAX TEMP [°C]: 38 MIN TEMP [°C]: -2 NO CONDUCTOR PERMITTED IN SHADED AREA A SCE METERING NOTES NTS GENERATOR CONDUCTORS CONNECT ON LOAD TERMINALS UTILITY CONDUCTORS CONNECT ON LINE TERMINALS SELF-CONTAINED ENCLOSURE COMBINATION CURRENT TRANSFORMER AND METER CAN 1.WIRING OF A NGO METER SOCKET FOR VIRTUAL NET METERING PROJECTS , THE GENERATOR SHALL BE CONNECTED TO THE LOAD SIDE OF THE NGO SOCKET. 2.THE HORIZONTAL CLEARANCE FROM THE CENTERLINE OF THE METER TO THE NEAREST SIDE WALL OR OTHER OBSTRUCTION SHALL BE 10" MINIMUM. A HORIZONTAL CLEARANCE FROM THE EDGE OF THE METER PANEL TO THE EDGE OF A WINDOW OR DOORWAY (INCLUDING SLIDING GLASS DOORS) SHALL BE 10" MINIMUM. 3.A CLEAR AND LEVEL WORKING SURFACE SHALL BE PROVIDED WITH A THE MINIMUM WIDTH OF THE WORKSPACE SHALL BE 36 AND A MINIMUM DEPTH OF 36". 4.THE MINIMUM HEIGHT OF THE METER SHALL BE 4' AND MAXIMUM HEIGHT SHALL NOT EXCEED 6'-3" MEASURED FROM STANDING SURFACE TO CENTERLINE OF METER SOCKET. 4.1.THE MINIMUM HEIGHT CAN BE REDUCED TO 3' IF LOCATED IN A METER ROOM. 5.DRAWING IS FOR WIRE REFERENCE ONLY AND IS NOT REFLECTIVE OF ACTUAL WIRE PENETRATIONS. 5 5 REMOVABLE TEST PERCH 5 5 ℄ ℄REFER TO DC STRING SCHEDULES FOR FOR STRING LENGTHS AND OPTIMIZER QUANTITY B STRING WIRING - SINGLE OPTIMIZER (TYP.) NTS NOTE: 1.NEGATIVE TOO RUN ALONG SIDE THE POSITIVE WIRE. ALL WIRES MUST BE SECURED TO UNDERSIDE OF THE RACKING AND MODULES USING SUNRUN APPROVED METHODS AND MATERIALS WITH APPROPRIATE UV AND ENVIRONMENTAL RATINGS. 2.CONDUIT TRANSITIONS SHALL BE MADE UNDER ARRAY. 3.INSTALL STRING LABELS ON BOTH ENDS OF HOMERUNS USING LABELS SUITABLE FOR THE ENVIRONMENT. 4.FIELD INSTALLED CONNECTOR, 1000VDC, MATING MUST MATCH MANUFACTURES RECOMMENDATIONS (TYP. TWO PER STRING) 5.TOTAL CIRCUIT LENGTH SHALL NOT EXCEED MANUFACTURE SPECIFICATIONS 6.FREE-AIR PV WIRE TO MATCH GAUGE OF DC-X.X CIRCUIT LOCATED ON DC WIRE SCHEDULES. 4 4 3 3 2 1 (N) SOLAREGDE OPTIMIZER (N) PV MODULE 5 6 150' MAX DISTANCE FOR WIRELESS OPTIONAL THIRD BATTERY (N) J-BOX WITH 3 OR 4 PORT POLARIS LUG OR EQUIV. (N) SOLAREDGE ENERGY BANK BAT-10K1P, WALL MOUNTED OR USING MANUFACTURES FLOOR STAND KIT (IAC-RBAT-FLRSTD-01) (N) SOLAREDGE HOME HUB INVERTER MC-4 CONNECTORS TO BATTERY CONNECTION UNIT ES-1 ES-2 #CONDUIT CONDUCTOR GROUND ES-1 FLOOR STAND INTERNAL CHANNEL OR 3/4" EMT OR EQUIV. (2) 10 AWG PV WIRE (1) 10 AWG THHN/THWN-2 ES-2 3/4" EMT OR EQUIV.(2) 8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 SOLAREDGE BESS WIRING NTSC OPTIMIZER A: MAKE/MODEL: SOLAREDGE U650 MAX INPUT POWER [W]: 650 MAX INPUT Voc [V]: 60 MAX INPUT Isc [A]: 15 OUTPUT CURRENT [A]: 15 MODULE A: MAKE/MODEL: QCELLS NORTH AMERICA Q.PEAK DUO BLK ML-G10.C+ 410 POWER [W]: 410 Voc [V]: 45.37 Isc [A]: 11.2 Vmp [V]: 37.64 Imp [A]: 10.89 Voc coeff. [%/degC]: -0.27% Isc coeff. [%/degC]: 0.04% # IN SERIES: 1 Vmax CALCULATION: 48.7 VDC = 1 X ( 45.37 VDC - ( 25 - (-2)°C X ( 45.37 X -0.0027 ) V/°C ) D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG ELECTRICAL NOTES CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH E500 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #ESTAMP WILSHIRE MINNIE 1209 E WILSHIRE AVE UNIT# MTR02 1209 3/4 E WILSHIRE AVE UNIT# ELE01 1221 E WILSHIRE AVE UNIT# MTR02 1221 3/4 E WILSHIRE AVE UNIT# ELE01 1229 E WILSHIRE AVE UNIT# MTR02 1229 3/4 E WILSHIRE AVE UNIT# ELE01 1233 E WILSHIRE AVE UNIT# MTR01 1401 S MINNIE ST UNIT# MTR01 1403 S MINNIE ST UNIT# MTR01 1425 S MINNIE ST UNIT# MTR01 APN: 014-251-49 / 014-251-50 DEVELOPER: C&C DEVELOPMENT ##KEYED NOTES#EQUIPMENT NOTES# # COMMUNICATION CAT5E 600V RATED SHIELDED CABLE. INSTALLER SHALL FOLLOW MANUFACTURES RECOMMENDATION FOR WIRE SIZING BASED ON LENGTH. CIRCUIT IDENTIFIER EQUIPMENT INDEX EQUIPMENT TYPE SYSTEM IDENTIFIER X INDICATES LETTERS # INDICATES NUMBERS XX-#.# SYSTEM SUMMARY 38.00 ACKW | 54.12 DCKW | 50.43 CECKW 38.00 BESS ACKW | 116.40 BESS KWH TOTAL FAULT CURRENTS UTILITY: 42,000A | GENERATORS: 296A DESCRIPTION OF OPERATION (DOO) 1.INVERTERS WITH ESS ARE CERTIFIED TO UL 1741 PCS CRD AND WILL HAVE EXPORT-ONLY MODES ENABLED. THEY WILL UTILIZE EXCESS PV POWER TO CHARGE THE BATTERIES AND THE BATTERIES WILL DISCHARGE DURING SET HOURS. 2.THE PRODUCER'S STORAGE DEVICE(S) WILL NOT CONSUME POWER FROM THE DISTRIBUTION PROVIDER'S DISTRIBUTION SYSTEM AT ANY TIME. 3.GRID EXPORT IS ALLOWED THROUGH NEMV METER. 4.DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO THE ACCEPTABLE MEASURE. +- 18 14 1 13 14 ES-1 (3 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 1 . 1 . A - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . ST R - 1 . 1 . B - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . ST R - 1 . 1 . C - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . 14 ES-2 DC-1.1.1 SO L A R 3 16 BA T T E R Y 7 12 4A A-B 60A INV-1.1 +- 18 14 1 13 14 ES-1 (3 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 1 . 2 . A - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . ST R - 1 . 2 . B - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . ST R - 1 . 2 . C - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . ES-2 DC-1.2.2 SO L A R 3 16 BA T T E R Y 7 12 4A A-B 60A INV-1.2 +- 18 14 1 13 14 ES-1 (3 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 1 . 3 . A - ( 1 2 ) 4 1 0 W M O D U L E W / ( 1 2 ) U 6 5 0 O P T S . ST R - 1 . 3 . B - ( 1 2 ) 4 1 0 W M O D U L E W / ( 1 2 ) U 6 5 0 O P T S . ES-2 DC-1.3.3 SO L A R 3 16 BA T T E R Y 7 12 4B A-B 40A INV-1.3 +- 18 14 1 13 14 ES-1 (3 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 1 . 4 . A - ( 1 2 ) 4 1 0 W M O D U L E W / ( 1 2 ) U 6 5 0 O P T S . ST R - 1 . 4 . B - ( 1 2 ) 4 1 0 W M O D U L E W / ( 1 2 ) U 6 5 0 O P T S . ES-2 DC-1.4.4 SO L A R 3 16 BA T T E R Y 7 12 4B A-B 40A INV-1.4 6 LC-1.1 6 8 5 (N) ACDS-2 SYSTEM AC DISCONNECT SWITCH,, SQUARE D, VHU364R, 600V RATED, 240V OPERATIONAL, 200A, 3 POLE, NON-FUSIBLE, NEMA 3R. VISIBLE, LOCKABLE. SEE REFERENCE SHEETS FOR KAIC RATING. AC-1.2 M9 4 (N) SCE PV PRODUCTION METER SOCKET ADDRESS: 1209 E WILSHIRE AVE UNIT# MTR02, COOPER B-LINE, 124TB, 200 A, SERVICE 1 PHASE 3 WIRE 120/240 VAC, NEMA 3R AC-1.2 10 3 (N) ACDS-1 SYSTEM UTILITY AC DISCONNECT SWITCH, SQUARE D, VH224NR, 240V RATED, 240V OPERATIONAL, 200A, 2 POLE, FUSIBLE, NEMA 3R, OR EQUIVALENT ON THE UTILITIES APPROVED LIST. VISIBLE, LOCKABLE. CLASS J FUSE, 200KAIC RATING. A-B 200AAC-1.1 M M M M M FACILITY LOADS (E) TENANT METERS (TYP.) (N) POLARIS BLOCK - A 11101 15 200A POI-1 DC STRING SCHEDULE STR-A STR-B STR-C TAG DESTINATION CIRCUIT LENGTH ²VD%MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES CIRCUIT LENGTH ²VD%MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES CIRCUIT LENGTH ²VD%MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES DC-1.1.1 INV-1.1 80 0.48%410 14 U650 8 / 16¹85 0.48%410 14 U650 8 / 16¹65 0.39%410 14 U650 8 / 16¹ DC-1.2.2 INV-1.2 100 0.59%410 14 U650 8 / 16¹80 0.45%410 14 U650 8 / 16¹75 0.45%410 14 U650 8 / 16¹ DC-1.3.3 INV-1.3 150 1.22%410 12 U650 8 / 16¹155 1.18%410 12 U650 8 / 16¹------------ DC-1.4.4 INV-1.4 155 1.26%410 12 U650 8 / 16¹135 1.03%410 12 U650 8 / 16¹------------ ¹ MAXIMUM STRING LENGTH IS USING MANUFACTURES EXCEPTION ² LENGTHS ARE ESTIMATED FOR CALCULATIONS, CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS AND TAKEOFFS ³ WHERE EXPOSED TO PHYSICAL DAMAGE #6 TO BE USED PER NEC 250.120(C) ⁴ AFC VALUES ARE CALCULATED BASED ON WIRE LENGTHS. LENGTHS SHOULD REMAIN GREATER THAN OR EQUAL TO THE LENGTH LISTED IN THE TABLE. A INTERCONNECTION LOCATION NTS1209 E WILSHIRE AVE UNIT# MTR02 POI-1 DC WIRE SCHEDULE TAG WIRE GAUGE CONDUCTOR JACKET MAX ISC 1.25 X MAX CIRCUIT AMPS CIRCUIT FUSE RATING CCC PER CONDUIT MAX AMBIENT TEMP (C) C.O.U TEMP. DERATE C.O.U CONDUIT FILL DERATE 75°C AMPACITY COMPLIES WITH 690.8(B)(1) 90°C AMPACITY WITH C.O.U COMPLIES WITH 690.8(B)(2) FAULT CURRENT FROM PARALLEL STRINGS COMPLIES WITH 690.9(A) GROUNDING PER CONDUIT GROUNDING ³EMT RMC PVC 40 PVC 80 DC-1.1.1 CU #8 THWN2 15 18.75 NONE 6 38 91%80%50 YES 40.0 YES 30 YES 3 CU #10 1"1"1"1 1/4" DC-1.2.2 CU #8 THWN2 15 18.75 NONE 6 38 91%80%50 YES 40.0 YES 30 YES 3 CU #10 1"1"1"1 1/4" DC-1.3.3 CU #10 THWN2 15 18.75 NONE 4 38 91%80%35 YES 29.1 YES 15 YES 2 CU #10 3/4"3/4"3/4"3/4" DC-1.4.4 CU #10 THWN2 15 18.75 NONE 4 38 91%80%35 YES 29.1 YES 15 YES 2 CU #10 3/4"3/4"3/4"3/4" LINE SIDE TAP VIA POLARIS TAPS (POINT OF INTERCONNECTION) SCE METER UTILITY METER REFERENCE NUMBER: 222012-828760 SCE UTILITY GRID 240V, 1ø,3W ENTRENCHED ~20' PVC-80 EMT EMT ENTRENCHED ~20' PVC-80 EMT EMT ENTRENCHED ~23.5' PVC-80 EMT EMT ENTRENCHED ~23.5' PVC-80 EMT EMT 14 14 14 ENTRENCHED ~20' PVC-80 EMT ENTRENCHED ~6' PVC-80 EMT ENTRENCHED ~23.5' PVC-80 EMT ENTRENCHED ~23.5' PVC-80 EMT ENTRENCHED ~20' PVC-80 EMT EMT EMT EMT EMT 1209 E WILSHIRE AVE E401 G BLDG 1209 GEC E401 G BLDG 1213 GEC E401 G BLDG 1201 GEC E401 G BLDG 1201 GEC 1209 E WILSHIRE AVE 1213 E WILSHIRE AVE 1201 E WILSHIRE AVE 1201 E WILSHIRE AVE PARKING STRUCTURE NEW ADDRESS TO BE ASSIGNED 1. PV MODULES (132) QCELLS NORTH AMERICA Q.PEAK DUO BLK ML-G10.C+ 410 2. (132) SOLAREDGE DC OPTIMIZER U650 3. DC PV AND ESS CONNECTION UNIT W/ INTEGRAL LOAD BREAK DISCONNECT 4. 4A: (2) SOLAREDGE SE11400H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM], 11,400W, 240VAC, 1ø, 3W 4B: (2) SOLAREDGE SE7600H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM], 7,600W, 240VAC, 1ø, 3W 5. (N) REVENUE GRADE METER, 1ø, INTERGRATED RGM, W/ NOT REQUIRED CTS 6. (1) LOAD CENTER, 200A, 1ø, MIN.240VAC, MIN. 10KAIC, NEMA 3R 7. NOT USED 8.(N) ACDS-2 SYSTEM AC DISCONNECT SWITCH, SQUARE D, VHU364R, 600V RATED, 240V OPERATIONAL, 200A, 3 POLE, NON-FUSIBLE, NEMA 3R. SEE REFERENCE SHEETS FOR KAIC RATING. 9. (N) SCE PV PRODUCTION METER SOCKET ADDRESS: 1209 E WILSHIRE AVE UNIT# MTR02, COOPER B-LINE, 124TB, 200A, SERVICE: 1 PHASE 3 WIRE 120/240 VAC, # JAW, NEMA 3R, EUSERC: 305 10. (N) ACDS-1 SYSTEM UTILITY AC DISCONNECT SWITCH, SQUARE D, VH224NR, 240V RATED, 240V OPERATIONAL, 200A, 2 POLE, FUSIBLE, NEMA 3R, OR EQUIVALENT ON THE UTILITIES APPROVED LIST. CLASS J FUSE, 200KAIC RATING. 11. (E) MAIN SERVICE EQUIPMENT: 1 PHASE 3 WIRE 120/240 VAC, 200A 12. (N) CELL-B-R05-US-S-S2 CELL CARD 13. (12) SOLAREDGE BAT-10K1P BATTERIES, 9.70KWH, 5,000DCW, NEMA 3R, MOUNTED TO WALL OR MANUFACTURER FLOOR MOUNT KIT 14. (N) DC DISCONNECT SWITCH 15. (N) POLARIS BLOCKS 16. NOT USED 1.(E) MAIN SWITCHGEAR AND (N) POINT OF AC INTERCONNECTION. ALL CONNECTIONS MADE INSIDE (E) SWITCHGEAR AT OTHER THAN CIRCUIT BREAKERS OR FUSED SWITCHES LISTED FOR USE WITH THAT SWITCHGEAR SHALL BE PERFORMED FOLLOWING MANUFACTURERS INSTRUCTIONS OR BE RE-LISTED BY A NRTL. ALL TERMINATIONS OF ALUMINUM CONDUCTORS SHALL BE WITH HIGH PRESS CRIMP LUGS ONLY. WARNING LABEL DETAIL 1/E800 2.(E) UTILITY TENANT LOAD METER. UTILITY REFERENCE METER NUMBER: 222012-828760 3.(N) PV SYSTEM UTILITY AC DISCONNECT 'ACDS-1'. WARNING LABEL DETAIL 1/E810 4.(N) UTILITY BIDIRECTIONAL KWH METER. WARNING LABEL DETAIL 1/E810 5.(N) PV SYSTEM MAINTENANCE AC DISCONNECT 'ACDS-2'. WARNING LABEL DETAIL 2/E800 & 1/E810 6.NOT USED 7.(N) GRID-INTERACTIVE PV INVERTER LISTED TO UL 1741 WITH GROUND FAULT DETECTION & INTERRUPTION. WARNING LABEL DETAIL 15/E800. 8.NOT USED 9.NOT USED 10.FOR SUPPLY SIDE CONNECTIONS, A PLAQUE SHALL BE INSTALLED AT THE MAIN SERVICE DISCONNECTING DEVICE AND THE PV SYSTEM UTILITY AC DISCONNECT INDICATING THE LOCATION OF THE RESPECTIVE SERVICE DISCONNECT. WARNING LABEL DETAIL 1/E800 & 1/E810 11.NOT USED 12.CONDUCTORS RUN IN PARALLEL SHALL BE INSTALLED PER ART 310.4/310.10(G) AND 250.122 (F). 13.NOT USED 14.NEW PULL/JUNCTION BOXES. PROVIDE SERVICE LOOP IN ALL DC BRANCH CONDUCTORS SOURCED FROM ROOFTOPS, MIN LOOP RADIUS = 12X CONDUCTOR DIAMETER. 15.NOT USED 16.(N) INVERTER INTERNAL DC DISCONNECT SWITCH(ES). WARNING LABEL DETAIL 3/E800 17.NOT USED 18.(N) PV MODULE LISTED TO UL 1703. 19.EXTRA MODULES THAT ARE UNABLE TO BE PAIRED WILL HAVE THEIR OWN OPTIMIZER. 20.(N) COMMUNICATION WIRING TO FOLLOW MANUFACTURING SPECIFICATIONS. 21.DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO THE ACCEPTED MEASURE. 22.BATTERY AC OUTPUT POWER IS LIMITED TO THE CORRESPONDING INVERTER OR TOTAL BATTERIES CONNECTED TO A SINGLE INVERTER,WHICHEVER IS LOWER. 23.BATTERIES SHOULD NOT BE INSTALLED IN DIRECT SUNLIGHT OR LOCATIONS SUBJECTED TO WATER SPRAY. SPRINKLERS SHOULD BE DIVERTED WHEN NECESSARY. 24.BATTERIES CAN COMMUNICATE WIRELESSLY OR VIA RS-485 TO INVERTER. BATTERIES WITHIN 150' (IDEALLY 50') OF RESPECTIVE INVERTER CAN USE WIRELESS COMMUNICATIONS VIA SEDG HOME NETWORK CARD. 25.COMBINED PV AND BESS OUTPUT POWER IS LIMITED TO THE INVERTER AC RATING. 26.SOLAREDGE ENERGY BANK MAY BE WALL, FLOOR, OR PAD MOUNTED INDIVIDUALLY OR IN GROUPS OF (2), (3), OR (4) UTILIZING THE SOLAREDGE FLOOR MOUNT STAND. ENERGY BANK MEETS THE UNIT LEVEL PERFORMANCE CRITERIA OF UL 9540A, ALLOWING ENERGY BANK TO BE STACKED FRONT TO BACK AS LONG AS THE CLEARANCE REQUIREMENTS ARE FOLLOWED TO ALLOW FOR AIR FLOW AROUND THE UNITS. RMC ONLY E500 D E500 D E500 D E500 D AHJ NOTES: 1.FUSED AC DISCONNECTS MUST BE SUSE RATED WITH A MAIN BONDING JUMPER INSTALLED. CEC 230.82(6) 2.THE "GROUND" WIRE OF FUSED AC DISCONNECTS IS A GROUNDING ELECTRODE CONDUCTOR TO BE BONDED TO THE GEC SYSTEM OF THE BUILDING 3.DISCONNECTS MUST BE WITHIN RMC TO THE POI. THE DISCONNECT AND THE SUPPLY-SIDE POI MUST BE SEALED BY SCE. THIS IS CITY POLICY FOR SE CONDUCTORS TO MINIMIZE POWER THEFT AND DAMAGE. TO GEC EGCRMC ONLY RMC ONLY UTILITY TERMINATION WEATHERHEAD - UTILITY TERMINATION POINT SCE CECTION CUSTOMER SECTION DISTANCE FROM FUSED ACD TO POI ~ 5 FT POI-1 AC WIRE SCHEDULE LABEL DESTINATION NOMINAL VAC LINE SELECTION FLA FLAX1.25 OCPD PHASE CONDUCTOR NEUTRAL CONDUCTOR GROUNDING CONDUCTOR CONDUCTORS PER PHASE CONDUIT QTY 75°C AMPS 90°C AMPS 90°C AMPS W/ C.O.U C.O.U TEMP DERATE C.O.U CONDUIT FILL CIRCUIT LENGTH ²SEGMENT VD%DC/AC RATIO AFC START AFC END ⁴EMT IMC PVC 40 PVC 80 INV-1.1 LC-1.1 240 A-B 47.5 59.4 60 CU #6 CU #10 CU #10 1 1 65 75 68.3 91%100%75 1.40%151.1%5,810 2,326 3/4"3/4"3/4"3/4" INV-1.2 LC-1.1 240 A-B 47.5 59.4 60 CU #6 CU #10 CU #10 1 1 65 75 68.3 91%100%75 1.40%151.1%5,810 2,326 3/4"3/4"3/4"3/4" INV-1.3 LC-1.1 240 A-B 31.7 39.6 40 CU #8 CU #10 CU #10 1 1 50 55 50.1 91%100%75 1.48%129.5%5,810 1,744 1/2"1/2"3/4"3/4" INV-1.4 LC-1.1 240 A-B 31.7 39.6 40 CU #8 CU #10 CU #10 1 1 50 55 50.1 91%100%75 1.48%129.5%5,810 1,744 1/2"1/2"3/4"3/4" LC-1.1 AC-1.2 240 A-B 158.3 197.9 200 CU #3/0 CU #6 CU #6 1 1 200 225 204.8 91%100%19 0.19%--6,258 5,810 1 1/2"1 1/4"1 1/2"1 1/2" AC-1.2 AC-1.1 240 A-B 158.3 197.9 200 CU #3/0 CU #6 CU #6 1 1 200 225 204.8 91%100%10 0.10%--6,523 6,258 1 1/2"1 1/4"1 1/2"1 1/2" AC-1.1 POI-1.1 240 A-B 158.3 197.9 200 CU #3/0 CU #3/0 CU #4 1 1 200 225 204.8 91%100%5 0.05%--42,000 36,964 2"1 1/2"2"2" D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG POI-1 ONE LINE CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH E600 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #ESTAMP WILSHIRE MINNIE 1209 E WILSHIRE AVE UNIT# MTR02 1209 3/4 E WILSHIRE AVE UNIT# ELE01 APN: 014-251-49 DEVELOPER: C&C DEVELOPMENT ##KEYED NOTES#EQUIPMENT NOTES# # COMMUNICATION CAT5E 600V RATED SHIELDED CABLE. INSTALLER SHALL FOLLOW MANUFACTURES RECOMMENDATION FOR WIRE SIZING BASED ON LENGTH. CIRCUIT IDENTIFIER EQUIPMENT INDEX EQUIPMENT TYPE SYSTEM IDENTIFIER X INDICATES LETTERS # INDICATES NUMBERS XX-#.# SYSTEM SUMMARY 34.20 ACKW | 47.56 DCKW | 44.32 CECKW 34.20 BESS ACKW | 87.30 BESS KWH TOTAL FAULT CURRENTS UTILITY: 42,000A | GENERATORS: 222A DESCRIPTION OF OPERATION (DOO) 1.INVERTERS WITH ESS ARE CERTIFIED TO UL 1741 PCS CRD AND WILL HAVE EXPORT-ONLY MODES ENABLED. THEY WILL UTILIZE EXCESS PV POWER TO CHARGE THE BATTERIES AND THE BATTERIES WILL DISCHARGE DURING SET HOURS. 2.THE PRODUCER'S STORAGE DEVICE(S) WILL NOT CONSUME POWER FROM THE DISTRIBUTION PROVIDER'S DISTRIBUTION SYSTEM AT ANY TIME. 3.GRID EXPORT IS ALLOWED THROUGH NEMV METER. 4.DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO THE ACCEPTABLE MEASURE. +- 18 14 1 13 14 ES-1 (3 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 2 . 1 . A - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . ST R - 2 . 1 . B - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . ST R - 2 . 1 . C - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . 14 ES-2 DC-2.1.1 SO L A R 3 16 BA T T E R Y 7 12 4 A-B 60A INV-2.1 +- 18 14 1 13 14 ES-1 (3 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 2 . 2 . A - ( 1 3 ) 4 1 0 W M O D U L E W / ( 1 3 ) U 6 5 0 O P T S . ST R - 2 . 2 . B - ( 1 2 ) 4 1 0 W M O D U L E W / ( 1 2 ) U 6 5 0 O P T S . ST R - 2 . 2 . C - ( 1 2 ) 4 1 0 W M O D U L E W / ( 1 2 ) U 6 5 0 O P T S . 14 ES-2 DC-2.2.2 SO L A R 3 16 BA T T E R Y 7 12 4 A-B 60A INV-2.2 +- 18 14 1 13 14 ES-1 (3 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 2 . 3 . A - ( 1 3 ) 4 1 0 W M O D U L E W / ( 1 3 ) U 6 5 0 O P T S . ST R - 2 . 3 . B - ( 1 2 ) 4 1 0 W M O D U L E W / ( 1 2 ) U 6 5 0 O P T S . ST R - 2 . 3 . C - ( 1 2 ) 4 1 0 W M O D U L E W / ( 1 2 ) U 6 5 0 O P T S . 14 ES-2 DC-2.3.3 SO L A R 3 16 BA T T E R Y 7 12 4 A-B 60A INV-2.3 6 LC-2.1 6 8 5 (N) ACDS-2 SYSTEM AC DISCONNECT SWITCH,, SQUARE D, VHU364R, 600V RATED, 240V OPERATIONAL, 200A, 3 POLE, NON-FUSIBLE, NEMA 3R. VISIBLE, LOCKABLE. SEE REFERENCE SHEETS FOR KAIC RATING. AC-2.2 M9 4 (N) SCE PV PRODUCTION METER SOCKET ADDRESS: 1221 E WILSHIRE AVE UNIT# MTR02, COOPER B-LINE, 124TB, 200 A, SERVICE 1 PHASE 3 WIRE 120/240 VAC, NEMA 3R AC-2.2 10 3 (N) ACDS-1 SYSTEM UTILITY AC DISCONNECT SWITCH, SQUARE D, VH224NR, 240V RATED, 240V OPERATIONAL, 200A, 2 POLE, FUSIBLE, NEMA 3R, OR EQUIVALENT ON THE UTILITIES APPROVED LIST. VISIBLE, LOCKABLE. CLASS J FUSE, 200KAIC RATING. A-B 200AAC-2.1 A INTERCONNECTION LOCATION NTS1221 E WILSHIRE AVE UNIT# MTR02 POI-2 DC STRING SCHEDULE STR-A STR-B STR-C TAG DESTINATION CIRCUIT LENGTH ²VD%MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES CIRCUIT LENGTH ²VD%MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES CIRCUIT LENGTH ²VD%MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES DC-2.1.1 INV-2.1 50 0.30%410 14 U650 8 / 16¹90 0.50%410 14 U650 8 / 16¹65 0.39%410 14 U650 8 / 16¹ DC-2.2.2 INV-2.2 80 0.44%410 13 U650 8 / 16¹75 0.36%410 12 U650 8 / 16¹120 0.61%410 12 U650 8 / 16¹ DC-2.3.3 INV-2.3 130 0.72%410 13 U650 8 / 16¹95 0.46%410 12 U650 8 / 16¹115 0.59%410 12 U650 8 / 16¹ ¹ MAXIMUM STRING LENGTH IS USING MANUFACTURES EXCEPTION ² LENGTHS ARE ESTIMATED FOR CALCULATIONS, CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS AND TAKEOFFS ³ WHERE EXPOSED TO PHYSICAL DAMAGE #6 TO BE USED PER NEC 250.120(C) ⁴ AFC VALUES ARE CALCULATED BASED ON WIRE LENGTHS. LENGTHS SHOULD REMAIN GREATER THAN OR EQUAL TO THE LENGTH LISTED IN THE TABLE. POI-2 DC WIRE SCHEDULE TAG WIRE GAUGE CONDUCTOR JACKET MAX ISC 1.25 X MAX CIRCUIT AMPS CIRCUIT FUSE RATING CCC PER CONDUIT MAX AMBIENT TEMP (C) C.O.U TEMP. DERATE C.O.U CONDUIT FILL DERATE 75°C AMPACITY COMPLIES WITH 690.8(B)(1) 90°C AMPACITY WITH C.O.U COMPLIES WITH 690.8(B)(2) FAULT CURRENT FROM PARALLEL STRINGS COMPLIES WITH 690.9(A) GROUNDING PER CONDUIT GROUNDING ³EMT RMC PVC 40 PVC 80 DC-2.1.1 CU #8 THWN2 15 18.75 NONE 6 38 91%80%50 YES 40.0 YES 30 YES 3 CU #10 1"1"1"1 1/4" DC-2.2.2 CU #8 THWN2 15 18.75 NONE 6 38 91%80%50 YES 40.0 YES 30 YES 3 CU #10 1"1"1"1 1/4" DC-2.3.3 CU #8 THWN2 15 18.75 NONE 6 38 91%80%50 YES 40.0 YES 30 YES 3 CU #10 1"1"1"1 1/4" LINE SIDE TAP VIA POLARIS TAPS (POINT OF INTERCONNECTION) SCE METER 1. PV MODULES (116) QCELLS NORTH AMERICA Q.PEAK DUO BLK ML-G10.C+ 410 2. (116) SOLAREDGE DC OPTIMIZER U650 3. DC PV AND ESS CONNECTION UNIT W/ INTEGRAL LOAD BREAK DISCONNECT 4. (3) SOLAREDGE SE11400H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM], 11,400W, 240VAC, 1ø, 3W 5. (N) REVENUE GRADE METER, 1ø, INTERGRATED RGM, W/ NOT REQUIRED CTS 6. (1) LOAD CENTER, 200A, 1ø, MIN.240VAC, MIN. 10KAIC, NEMA 3R 7. NOT USED 8.(N) ACDS-2 SYSTEM AC DISCONNECT SWITCH, SQUARE D, VHU364R, 600V RATED, 240V OPERATIONAL, 200A, 3 POLE, NON-FUSIBLE, NEMA 3R. SEE REFERENCE SHEETS FOR KAIC RATING. 9. (N) SCE PV PRODUCTION METER SOCKET ADDRESS: 1221 E WILSHIRE AVE UNIT# MTR02, COOPER B-LINE, 124TB, 200A, SERVICE: 1 PHASE 3 WIRE 120/240 VAC, # JAW, NEMA 3R, EUSERC: 305 10. (N) ACDS-1 SYSTEM UTILITY AC DISCONNECT SWITCH, SQUARE D, VH224NR, 240V RATED, 240V OPERATIONAL, 200A, 2 POLE, FUSIBLE, NEMA 3R, OR EQUIVALENT ON THE UTILITIES APPROVED LIST. CLASS J FUSE, 200KAIC RATING. 11. (E) MAIN SERVICE EQUIPMENT: 1 PHASE 3 WIRE 120/240 VAC, 200A 12. (N) CELL-B-R05-US-S-S2 CELL CARD 13. (9) SOLAREDGE BAT-10K1P BATTERIES, 9.70KWH, 5,000DCW, NEMA 3R, MOUNTED TO WALL OR MANUFACTURER FLOOR MOUNT KIT 14. (N) DC DISCONNECT SWITCH 15. (N) POLARIS BLOCKS 16. NOT USED 1.(E) MAIN SWITCHGEAR AND (N) POINT OF AC INTERCONNECTION. ALL CONNECTIONS MADE INSIDE (E) SWITCHGEAR AT OTHER THAN CIRCUIT BREAKERS OR FUSED SWITCHES LISTED FOR USE WITH THAT SWITCHGEAR SHALL BE PERFORMED FOLLOWING MANUFACTURERS INSTRUCTIONS OR BE RE-LISTED BY A NRTL. ALL TERMINATIONS OF ALUMINUM CONDUCTORS SHALL BE WITH HIGH PRESS CRIMP LUGS ONLY. WARNING LABEL DETAIL 1/E800 2.(E) UTILITY TENANT LOAD METER. UTILITY REFERENCE METER NUMBER: 222010-847068 3.(N) PV SYSTEM UTILITY AC DISCONNECT 'ACDS-1'. WARNING LABEL DETAIL 1/E810 4.(N) UTILITY BIDIRECTIONAL KWH METER. WARNING LABEL DETAIL 1/E810 5.(N) PV SYSTEM MAINTENANCE AC DISCONNECT 'ACDS-2'. WARNING LABEL DETAIL 2/E800 & 1/E810 6.NOT USED 7.(N) GRID-INTERACTIVE PV INVERTER LISTED TO UL 1741 WITH GROUND FAULT DETECTION & INTERRUPTION. WARNING LABEL DETAIL 15/E800. 8.NOT USED 9.NOT USED 10.FOR SUPPLY SIDE CONNECTIONS, A PLAQUE SHALL BE INSTALLED AT THE MAIN SERVICE DISCONNECTING DEVICE AND THE PV SYSTEM UTILITY AC DISCONNECT INDICATING THE LOCATION OF THE RESPECTIVE SERVICE DISCONNECT. WARNING LABEL DETAIL 1/E800 & 1/E810 11.NOT USED 12.CONDUCTORS RUN IN PARALLEL SHALL BE INSTALLED PER ART 310.4/310.10(G) AND 250.122 (F). 13.NOT USED 14.NEW PULL/JUNCTION BOXES. PROVIDE SERVICE LOOP IN ALL DC BRANCH CONDUCTORS SOURCED FROM ROOFTOPS, MIN LOOP RADIUS = 12X CONDUCTOR DIAMETER. 15.NOT USED 16.(N) INVERTER INTERNAL DC DISCONNECT SWITCH(ES). WARNING LABEL DETAIL 3/E800 17.NOT USED 18.(N) PV MODULE LISTED TO UL 1703. 19.EXTRA MODULES THAT ARE UNABLE TO BE PAIRED WILL HAVE THEIR OWN OPTIMIZER. 20.(N) COMMUNICATION WIRING TO FOLLOW MANUFACTURING SPECIFICATIONS. 21.DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO THE ACCEPTED MEASURE. 22.BATTERY AC OUTPUT POWER IS LIMITED TO THE CORRESPONDING INVERTER OR TOTAL BATTERIES CONNECTED TO A SINGLE INVERTER,WHICHEVER IS LOWER. 23.BATTERIES SHOULD NOT BE INSTALLED IN DIRECT SUNLIGHT OR LOCATIONS SUBJECTED TO WATER SPRAY. SPRINKLERS SHOULD BE DIVERTED WHEN NECESSARY. 24.BATTERIES CAN COMMUNICATE WIRELESSLY OR VIA RS-485 TO INVERTER. BATTERIES WITHIN 150' (IDEALLY 50') OF RESPECTIVE INVERTER CAN USE WIRELESS COMMUNICATIONS VIA SEDG HOME NETWORK CARD. 25.COMBINED PV AND BESS OUTPUT POWER IS LIMITED TO THE INVERTER AC RATING. 26.SOLAREDGE ENERGY BANK MAY BE WALL, FLOOR, OR PAD MOUNTED INDIVIDUALLY OR IN GROUPS OF (2), (3), OR (4) UTILIZING THE SOLAREDGE FLOOR MOUNT STAND. ENERGY BANK MEETS THE UNIT LEVEL PERFORMANCE CRITERIA OF UL 9540A, ALLOWING ENERGY BANK TO BE STACKED FRONT TO BACK AS LONG AS THE CLEARANCE REQUIREMENTS ARE FOLLOWED TO ALLOW FOR AIR FLOW AROUND THE UNITS. ENTRENCHED ~10' PVC-80 EMT EMT ENTRENCHED ~10' PVC-80 EMT EMT ENTRENCHED ~10' PVC-80 EMT EMT ENTRENCHED ~10' PVC-80 EMT EMT ENTRENCHED ~10' PVC-80 EMT ENTRENCHED ~10' PVC-80 EMT EMT ENTRENCHED ~10' PVC-80 EMT ENTRENCHED ~10' PVC-80 EMT EMT M M M M M FACILITY LOADS (E) TENANT METERS (TYP.) (N) POLARIS BLOCK - A 11101 15 200A UTILITY METER REFERENCE NUMBER: 222010-847068 SCE UTILITY GRID 240V, 1ø,3W RMC ONLY 1221 E WILSHIRE AVE E401 G BLDG 1221 GEC 1221 E WILSHIRE AVE E401 G BLDG 1225 GEC 1225 E WILSHIRE AVE E401 G BLDG 1225 GEC 1225 E WILSHIRE AVE E500 D E500 D E500 D PARKING STRUCTURE NEW ADDRESS TO BE ASSIGNED AHJ NOTES: 1.FUSED AC DISCONNECTS MUST BE SUSE RATED WITH A MAIN BONDING JUMPER INSTALLED. CEC 230.82(6) 2.THE "GROUND" WIRE OF FUSED AC DISCONNECTS IS A GROUNDING ELECTRODE CONDUCTOR TO BE BONDED TO THE GEC SYSTEM OF THE BUILDING 3.DISCONNECTS MUST BE WITHIN RMC TO THE POI. THE DISCONNECT AND THE SUPPLY-SIDE POI MUST BE SEALED BY SCE. THIS IS CITY POLICY FOR SE CONDUCTORS TO MINIMIZE POWER THEFT AND DAMAGE. TO GEC EGCRMC ONLY RMC ONLY WEATHERHEAD - UTILITY TERMINATION POINT SCE CECTION CUSTOMER SECTION DISTANCE FROM FUSED ACD TO POI ~ 5 FT UTILITY TERMINATION POI-2 AC WIRE SCHEDULE LABEL DESTINATION NOMINAL VAC LINE SELECTION FLA FLAX1.25 OCPD PHASE CONDUCTOR NEUTRAL CONDUCTOR GROUNDING CONDUCTOR CONDUCTORS PER PHASE CONDUIT QTY 75°C AMPS 90°C AMPS 90°C AMPS W/ C.O.U C.O.U TEMP DERATE C.O.U CONDUIT FILL CIRCUIT LENGTH ²SEGMENT VD%DC/AC RATIO AFC START AFC END ⁴EMT IMC PVC 40 PVC 80 INV-2.1 LC-2.1 240 A-B 47.5 59.4 60 CU #6 CU #10 CU #10 1 1 65 75 68.3 91%100%60 1.12%151.1%5,810 2,643 3/4"3/4"3/4"3/4" INV-2.2 LC-2.1 240 A-B 47.5 59.4 60 CU #6 CU #10 CU #10 1 1 65 75 68.3 91%100%60 1.12%133.1%5,810 2,643 3/4"3/4"3/4"3/4" INV-2.3 LC-2.1 240 A-B 47.5 59.4 60 CU #6 CU #10 CU #10 1 1 65 75 68.3 91%100%60 1.12%133.1%5,810 2,643 3/4"3/4"3/4"3/4" LC-2.1 AC-2.2 240 A-B 142.5 178.1 200 CU #3/0 CU #6 CU #6 1 1 200 225 204.8 91%100%19 0.17%--6,258 5,810 1 1/2"1 1/4"1 1/2"1 1/2" AC-2.2 AC-2.1 240 A-B 142.5 178.1 200 CU #3/0 CU #6 CU #6 1 1 200 225 204.8 91%100%10 0.09%--6,523 6,258 1 1/2"1 1/4"1 1/2"1 1/2" AC-2.1 POI-2.2 240 A-B 142.5 178.1 200 CU #3/0 CU #3/0 CU #4 1 1 200 225 204.8 91%100%5 0.05%--42,000 36,964 2"1 1/2"2"2" D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG POI-2 ONE LINE CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH E601 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #ESTAMP WILSHIRE MINNIE 1221 E WILSHIRE AVE UNIT# MTR02 1221 3/4 E WILSHIRE AVE UNIT# ELE01 APN: 014-251-49 DEVELOPER: C&C DEVELOPMENT ##KEYED NOTES#EQUIPMENT NOTES# # COMMUNICATION CAT5E 600V RATED SHIELDED CABLE. INSTALLER SHALL FOLLOW MANUFACTURES RECOMMENDATION FOR WIRE SIZING BASED ON LENGTH. CIRCUIT IDENTIFIER EQUIPMENT INDEX EQUIPMENT TYPE SYSTEM IDENTIFIER X INDICATES LETTERS # INDICATES NUMBERS XX-#.# SYSTEM SUMMARY 34.20 ACKW | 46.74 DCKW | 43.55 CECKW 34.20 BESS ACKW | 87.30 BESS KWH TOTAL FAULT CURRENTS UTILITY: 42,000A | GENERATORS: 222A DESCRIPTION OF OPERATION (DOO) 1.INVERTERS WITH ESS ARE CERTIFIED TO UL 1741 PCS CRD AND WILL HAVE EXPORT-ONLY MODES ENABLED. THEY WILL UTILIZE EXCESS PV POWER TO CHARGE THE BATTERIES AND THE BATTERIES WILL DISCHARGE DURING SET HOURS. 2.THE PRODUCER'S STORAGE DEVICE(S) WILL NOT CONSUME POWER FROM THE DISTRIBUTION PROVIDER'S DISTRIBUTION SYSTEM AT ANY TIME. 3.GRID EXPORT IS ALLOWED THROUGH NEMV METER. 4.DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO THE ACCEPTABLE MEASURE. +- 18 14 1 13 14 ES-1 (3 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 3 . 1 . A - ( 1 2 ) 4 1 0 W M O D U L E W / ( 1 2 ) U 6 5 0 O P T S . ST R - 3 . 1 . B - ( 1 2 ) 4 1 0 W M O D U L E W / ( 1 2 ) U 6 5 0 O P T S . ST R - 3 . 1 . C - ( 1 2 ) 4 1 0 W M O D U L E W / ( 1 2 ) U 6 5 0 O P T S . 14 ES-2 DC-3.1.1 SO L A R 3 16 BA T T E R Y 7 12 4 A-B 60A INV-3.1 +- 18 14 1 13 14 ES-1 (3 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 3 . 2 . A - ( 1 2 ) 4 1 0 W M O D U L E W / ( 1 2 ) U 6 5 0 O P T S . ST R - 3 . 2 . B - ( 1 2 ) 4 1 0 W M O D U L E W / ( 1 2 ) U 6 5 0 O P T S . ST R - 3 . 2 . C - ( 1 2 ) 4 1 0 W M O D U L E W / ( 1 2 ) U 6 5 0 O P T S . 14 ES-2 DC-3.2.2 SO L A R 3 16 BA T T E R Y 7 12 4 A-B 60A INV-3.2 +- 18 14 1 13 14 ES-1 (3 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 3 . 3 . A - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . ST R - 3 . 3 . B - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . ST R - 3 . 3 . C - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . 14 ES-2 DC-3.3.3 SO L A R 3 16 BA T T E R Y 7 12 4 A-B 60A INV-3.3 6 LC-3.1 6 8 5 (N) ACDS-2 SYSTEM AC DISCONNECT SWITCH,, SQUARE D, VHU364R, 600V RATED, 240V OPERATIONAL, 200A, 3 POLE, NON-FUSIBLE, NEMA 3R. VISIBLE, LOCKABLE. SEE REFERENCE SHEETS FOR KAIC RATING. AC-3.2 M9 4 (N) SCE PV PRODUCTION METER SOCKET ADDRESS: 1229 E WILSHIRE AVE UNIT# MTR02, COOPER B-LINE, 124TB, 200 A, SERVICE 1 PHASE 3 WIRE 120/240 VAC, NEMA 3R AC-3.2 10 3 (N) ACDS-1 SYSTEM UTILITY AC DISCONNECT SWITCH, SQUARE D, VH224NR, 240V RATED, 240V OPERATIONAL, 200A, 2 POLE, FUSIBLE, NEMA 3R, OR EQUIVALENT ON THE UTILITIES APPROVED LIST. VISIBLE, LOCKABLE. CLASS J FUSE, 200KAIC RATING. A-B 200A AC-3.1 A INTERCONNECTION LOCATION NTS 1229 E WILSHIRE AVE UNIT# MTR02 POI-3 DC STRING SCHEDULE STR-A STR-B STR-C TAG DESTINATION CIRCUIT LENGTH ²VD%MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES CIRCUIT LENGTH ²VD%MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES CIRCUIT LENGTH ²VD%MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES DC-3.1.1 INV-3.1 60 0.31%410 12 U650 8 / 16¹85 0.41%410 12 U650 8 / 16¹90 0.46%410 12 U650 8 / 16¹ DC-3.2.2 INV-3.2 60 0.31%410 12 U650 8 / 16¹65 0.31%410 12 U650 8 / 16¹80 0.41%410 12 U650 8 / 16¹ DC-3.3.3 INV-3.3 100 0.59%410 14 U650 8 / 16¹105 0.59%410 14 U650 8 / 16¹110 0.65%410 14 U650 8 / 16¹ ¹ MAXIMUM STRING LENGTH IS USING MANUFACTURES EXCEPTION ² LENGTHS ARE ESTIMATED FOR CALCULATIONS, CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS AND TAKEOFFS ³ WHERE EXPOSED TO PHYSICAL DAMAGE #6 TO BE USED PER NEC 250.120(C) ⁴ AFC VALUES ARE CALCULATED BASED ON WIRE LENGTHS. LENGTHS SHOULD REMAIN GREATER THAN OR EQUAL TO THE LENGTH LISTED IN THE TABLE. POI-3 DC WIRE SCHEDULE TAG WIRE GAUGE CONDUCTOR JACKET MAX ISC 1.25 X MAX CIRCUIT AMPS CIRCUIT FUSE RATING CCC PER CONDUIT MAX AMBIENT TEMP (C) C.O.U TEMP. DERATE C.O.U CONDUIT FILL DERATE 75°C AMPACITY COMPLIES WITH 690.8(B)(1) 90°C AMPACITY WITH C.O.U COMPLIES WITH 690.8(B)(2) FAULT CURRENT FROM PARALLEL STRINGS COMPLIES WITH 690.9(A) GROUNDING PER CONDUIT GROUNDING ³EMT RMC PVC 40 PVC 80 DC-3.1.1 CU #8 THWN2 15 18.75 NONE 6 38 91%80%50 YES 40.0 YES 30 YES 3 CU #10 1"1"1"1 1/4" DC-3.2.2 CU #8 THWN2 15 18.75 NONE 6 38 91%80%50 YES 40.0 YES 30 YES 3 CU #10 1"1"1"1 1/4" DC-3.3.3 CU #8 THWN2 15 18.75 NONE 6 38 91%80%50 YES 40.0 YES 30 YES 3 CU #10 1"1"1"1 1/4" LINE SIDE TAP VIA POLARIS TAPS (POINT OF INTERCONNECTION) SCE METER 1. PV MODULES (114) QCELLS NORTH AMERICA Q.PEAK DUO BLK ML-G10.C+ 410 2. (114) SOLAREDGE DC OPTIMIZER U650 3. DC PV AND ESS CONNECTION UNIT W/ INTEGRAL LOAD BREAK DISCONNECT 4. (3) SOLAREDGE SE11400H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM], 11,400W, 240VAC, 1ø, 3W 5. (N) REVENUE GRADE METER, 1ø, INTERGRATED RGM, W/ NOT REQUIRED CTS 6. (1) LOAD CENTER, 200A, 1ø, MIN.240VAC, MIN. 10KAIC, NEMA 3R 7. NOT USED 8.(N) ACDS-2 SYSTEM AC DISCONNECT SWITCH, SQUARE D, VHU364R, 600V RATED, 240V OPERATIONAL, 200A, 3 POLE, NON-FUSIBLE, NEMA 3R. SEE REFERENCE SHEETS FOR KAIC RATING. 9. (N) SCE PV PRODUCTION METER SOCKET ADDRESS: 1229 E WILSHIRE AVE UNIT# MTR02, COOPER B-LINE, 124TB, 200A, SERVICE: 1 PHASE 3 WIRE 120/240 VAC, # JAW, NEMA 3R, EUSERC: 305 10. (N) ACDS-1 SYSTEM UTILITY AC DISCONNECT SWITCH, SQUARE D, VH224NR, 240V RATED, 240V OPERATIONAL, 200A, 2 POLE, FUSIBLE, NEMA 3R, OR EQUIVALENT ON THE UTILITIES APPROVED LIST. CLASS J FUSE, 200KAIC RATING. 11. (E) MAIN SERVICE EQUIPMENT: 1 PHASE 3 WIRE 120/240 VAC, 200A 12. (N) CELL-B-R05-US-S-S2 CELL CARD 13. (9) SOLAREDGE BAT-10K1P BATTERIES, 9.70KWH, 5,000DCW, NEMA 3R, MOUNTED TO WALL OR MANUFACTURER FLOOR MOUNT KIT 14. (N) DC DISCONNECT SWITCH 15. (N) POLARIS BLOCKS 16. NOT USED 1.(E) MAIN SWITCHGEAR AND (N) POINT OF AC INTERCONNECTION. ALL CONNECTIONS MADE INSIDE (E) SWITCHGEAR AT OTHER THAN CIRCUIT BREAKERS OR FUSED SWITCHES LISTED FOR USE WITH THAT SWITCHGEAR SHALL BE PERFORMED FOLLOWING MANUFACTURERS INSTRUCTIONS OR BE RE-LISTED BY A NRTL. ALL TERMINATIONS OF ALUMINUM CONDUCTORS SHALL BE WITH HIGH PRESS CRIMP LUGS ONLY. WARNING LABEL DETAIL 1/E800 2.(E) UTILITY TENANT LOAD METER. UTILITY REFERENCE METER NUMBER: 222012-828414 3.(N) PV SYSTEM UTILITY AC DISCONNECT 'ACDS-1'. WARNING LABEL DETAIL 1/E810 4.(N) UTILITY BIDIRECTIONAL KWH METER. WARNING LABEL DETAIL 1/E810 5.(N) PV SYSTEM MAINTENANCE AC DISCONNECT 'ACDS-2'. WARNING LABEL DETAIL 2/E800 & 1/E810 6.NOT USED 7.(N) GRID-INTERACTIVE PV INVERTER LISTED TO UL 1741 WITH GROUND FAULT DETECTION & INTERRUPTION. WARNING LABEL DETAIL 15/E800. 8.NOT USED 9.NOT USED 10.FOR SUPPLY SIDE CONNECTIONS, A PLAQUE SHALL BE INSTALLED AT THE MAIN SERVICE DISCONNECTING DEVICE AND THE PV SYSTEM UTILITY AC DISCONNECT INDICATING THE LOCATION OF THE RESPECTIVE SERVICE DISCONNECT. WARNING LABEL DETAIL 1/E800 & 1/E810 11.NOT USED 12.CONDUCTORS RUN IN PARALLEL SHALL BE INSTALLED PER ART 310.4/310.10(G) AND 250.122 (F). 13.NOT USED 14.NEW PULL/JUNCTION BOXES. PROVIDE SERVICE LOOP IN ALL DC BRANCH CONDUCTORS SOURCED FROM ROOFTOPS, MIN LOOP RADIUS = 12X CONDUCTOR DIAMETER. 15.NOT USED 16.(N) INVERTER INTERNAL DC DISCONNECT SWITCH(ES). WARNING LABEL DETAIL 3/E800 17.NOT USED 18.(N) PV MODULE LISTED TO UL 1703. 19.EXTRA MODULES THAT ARE UNABLE TO BE PAIRED WILL HAVE THEIR OWN OPTIMIZER. 20.(N) COMMUNICATION WIRING TO FOLLOW MANUFACTURING SPECIFICATIONS. 21.DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO THE ACCEPTED MEASURE. 22.BATTERY AC OUTPUT POWER IS LIMITED TO THE CORRESPONDING INVERTER OR TOTAL BATTERIES CONNECTED TO A SINGLE INVERTER,WHICHEVER IS LOWER. 23.BATTERIES SHOULD NOT BE INSTALLED IN DIRECT SUNLIGHT OR LOCATIONS SUBJECTED TO WATER SPRAY. SPRINKLERS SHOULD BE DIVERTED WHEN NECESSARY. 24.BATTERIES CAN COMMUNICATE WIRELESSLY OR VIA RS-485 TO INVERTER. BATTERIES WITHIN 150' (IDEALLY 50') OF RESPECTIVE INVERTER CAN USE WIRELESS COMMUNICATIONS VIA SEDG HOME NETWORK CARD. 25.COMBINED PV AND BESS OUTPUT POWER IS LIMITED TO THE INVERTER AC RATING. 26.SOLAREDGE ENERGY BANK MAY BE WALL, FLOOR, OR PAD MOUNTED INDIVIDUALLY OR IN GROUPS OF (2), (3), OR (4) UTILIZING THE SOLAREDGE FLOOR MOUNT STAND. ENERGY BANK MEETS THE UNIT LEVEL PERFORMANCE CRITERIA OF UL 9540A, ALLOWING ENERGY BANK TO BE STACKED FRONT TO BACK AS LONG AS THE CLEARANCE REQUIREMENTS ARE FOLLOWED TO ALLOW FOR AIR FLOW AROUND THE UNITS. ENTRENCHED ~13' PVC-80 EMT EMT ENTRENCHED ~13' PVC-80 EMT EMT ENTRENCHED ~13' PVC-80 EMT EMT ENTRENCHED ~13' PVC-80 EMT EMT ENTRENCHED ~13' PVC-80 EMT EMT ENTRENCHED ~20' PVC-80 EMT ENTRENCHED ~13' PVC-80 EMT EMT M M M M M FACILITY LOADS (E) TENANT METERS (TYP.) (N) POLARIS BLOCK - A 11101 15 200A UTILITY METER REFERENCE NUMBER: 222012-828414 SCE UTILITY GRID 240V, 1ø,3W RMC ONLY 1229 E WILSHIRE AVE E401 G BLDG 1229 GEC 1229 E WILSHIRE AVE E401 G BLDG 1229 GEC 1229 E WILSHIRE AVE E401 G BLDG 1235 GEC 1235 E WILSHIRE AVE E500 D E500 D E500 D PARKING STRUCTURE NEW ADDRESS TO BE ASSIGNED AHJ NOTES: 1.FUSED AC DISCONNECTS MUST BE SUSE RATED WITH A MAIN BONDING JUMPER INSTALLED. CEC 230.82(6) 2.THE "GROUND" WIRE OF FUSED AC DISCONNECTS IS A GROUNDING ELECTRODE CONDUCTOR TO BE BONDED TO THE GEC SYSTEM OF THE BUILDING 3.DISCONNECTS MUST BE WITHIN RMC TO THE POI. THE DISCONNECT AND THE SUPPLY-SIDE POI MUST BE SEALED BY SCE. THIS IS CITY POLICY FOR SE CONDUCTORS TO MINIMIZE POWER THEFT AND DAMAGE. TO GEC EGCRMC ONLY RMC ONLY WEATHERHEAD - UTILITY TERMINATION POINT SCE CECTION CUSTOMER SECTION DISTANCE FROM FUSED ACD TO POI ~ 5 FT UTILITY TERMINATION POI-3 AC WIRE SCHEDULE LABEL DESTINATION NOMINAL VAC LINE SELECTION FLA FLAX1.25 OCPD PHASE CONDUCTOR NEUTRAL CONDUCTOR GROUNDING CONDUCTOR CONDUCTORS PER PHASE CONDUIT QTY 75°C AMPS 90°C AMPS 90°C AMPS W/ C.O.U C.O.U TEMP DERATE C.O.U CONDUIT FILL CIRCUIT LENGTH ²SEGMENT VD%DC/AC RATIO AFC START AFC END ⁴EMT IMC PVC 40 PVC 80 INV-3.1 LC-3.1 240 A-B 47.5 59.4 60 CU #6 CU #10 CU #10 1 1 65 75 68.3 91%100%65 1.21%129.5%5,810 2,528 3/4"3/4"3/4"3/4" INV-3.2 LC-3.1 240 A-B 47.5 59.4 60 CU #6 CU #10 CU #10 1 1 65 75 68.3 91%100%65 1.21%129.5%5,810 2,528 3/4"3/4"3/4"3/4" INV-3.3 LC-3.1 240 A-B 47.5 59.4 60 CU #6 CU #10 CU #10 1 1 65 75 68.3 91%100%65 1.21%151.1%5,810 2,528 3/4"3/4"3/4"3/4" LC-3.1 AC-3.2 240 A-B 142.5 178.1 200 CU #3/0 CU #6 CU #6 1 1 200 225 204.8 91%100%19 0.17%--6,258 5,810 1 1/2"1 1/4"1 1/2"1 1/2" AC-3.2 AC-3.1 240 A-B 142.5 178.1 200 CU #3/0 CU #6 CU #6 1 1 200 225 204.8 91%100%10 0.09%--6,523 6,258 1 1/2"1 1/4"1 1/2"1 1/2" AC-3.1 POI-3.3 240 A-B 142.5 178.1 200 CU #3/0 CU #3/0 CU #4 1 1 200 225 204.8 91%100%5 0.05%--42,000 36,964 2"1 1/2"2"2" D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG POI-3 ONE LINE CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH E602 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #ESTAMP WILSHIRE MINNIE 1229 E WILSHIRE AVE UNIT# MTR02 1229 3/4 E WILSHIRE AVE UNIT# ELE01 APN: 014-251-49 DEVELOPER: C&C DEVELOPMENT ##KEYED NOTES#EQUIPMENT NOTES# # COMMUNICATION CAT5E 600V RATED SHIELDED CABLE. INSTALLER SHALL FOLLOW MANUFACTURES RECOMMENDATION FOR WIRE SIZING BASED ON LENGTH. CIRCUIT IDENTIFIER EQUIPMENT INDEX EQUIPMENT TYPE SYSTEM IDENTIFIER X INDICATES LETTERS # INDICATES NUMBERS XX-#.# SYSTEM SUMMARY 19.00 ACKW | 28.70 DCKW | 26.74 CECKW 19.00 BESS ACKW | 58.20 BESS KWH TOTAL FAULT CURRENTS UTILITY: 42,000A | GENERATORS: 148A DESCRIPTION OF OPERATION (DOO) 1.INVERTERS WITH ESS ARE CERTIFIED TO UL 1741 PCS CRD AND WILL HAVE EXPORT-ONLY MODES ENABLED. THEY WILL UTILIZE EXCESS PV POWER TO CHARGE THE BATTERIES AND THE BATTERIES WILL DISCHARGE DURING SET HOURS. 2.THE PRODUCER'S STORAGE DEVICE(S) WILL NOT CONSUME POWER FROM THE DISTRIBUTION PROVIDER'S DISTRIBUTION SYSTEM AT ANY TIME. 3.GRID EXPORT IS ALLOWED THROUGH NEMV METER. 4.DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO THE ACCEPTABLE MEASURE. +- 18 14 1 13 14 ES-1 (3 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 4 . 1 . A - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . ST R - 4 . 1 . B - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . ST R - 4 . 1 . C - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . 14 ES-2 DC-4.1.1 SO L A R 3 16 BA T T E R Y 7 12 4A A-B 60A INV-4.1 +- 18 14 1 13 14 ES-1 (3 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 4 . 2 . A - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . ST R - 4 . 2 . B - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . 14 ES-2 DC-4.2.2 SO L A R 3 16 BA T T E R Y 7 12 4B A-B 40A INV-4.2 6 LC-4.1 6 8 5 (N) ACDS-2 SYSTEM AC DISCONNECT SWITCH,, SQUARE D, VHU363RB, 600V RATED, 240V OPERATIONAL, 100A, 3 POLE, NON-FUSIBLE, NEMA 3R. VISIBLE, LOCKABLE. SEE REFERENCE SHEETS FOR KAIC RATING. AC-4.2 M9 4 (N) SCE PV PRODUCTION METER SOCKET ADDRESS: 1233 E WILSHIRE AVE UNIT# MTR01, COOPER B-LINE, 114TB, 100 A, SERVICE 1 PHASE 3 WIRE 120/240 VAC, NEMA 3R AC-4.2 10 3 (N) ACDS-1 SYSTEM UTILITY AC DISCONNECT SWITCH, SQUARE D, VH223NRB, 240V RATED, 240V OPERATIONAL, 100A, 2 POLE, FUSIBLE, NEMA 3R, OR EQUIVALENT ON THE UTILITIES APPROVED LIST. VISIBLE, LOCKABLE. CLASS J FUSE, 200KAIC RATING. A-B 100A AC-4.1 A INTERCONNECTION LOCATION NTS1233 E WILSHIRE AVE UNIT# MTR01 POI-4 DC STRING SCHEDULE STR-A STR-B STR-C TAG DESTINATION CIRCUIT LENGTH ²VD%MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES CIRCUIT LENGTH ²VD%MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES CIRCUIT LENGTH ²VD%MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES DC-4.1.1 INV-4.1 70 0.42%410 14 U650 8 / 16¹100 0.56%410 14 U650 8 / 16¹75 0.45%410 14 U650 8 / 16¹ DC-4.2.2 INV-4.2 75 0.71%410 14 U650 8 / 16¹50 0.45%410 14 U650 8 / 16¹------------ ¹ MAXIMUM STRING LENGTH IS USING MANUFACTURES EXCEPTION ² LENGTHS ARE ESTIMATED FOR CALCULATIONS, CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS AND TAKEOFFS ³ WHERE EXPOSED TO PHYSICAL DAMAGE #6 TO BE USED PER NEC 250.120(C) ⁴ AFC VALUES ARE CALCULATED BASED ON WIRE LENGTHS. LENGTHS SHOULD REMAIN GREATER THAN OR EQUAL TO THE LENGTH LISTED IN THE TABLE. POI-4 DC WIRE SCHEDULE TAG WIRE GAUGE CONDUCTOR JACKET MAX ISC 1.25 X MAX CIRCUIT AMPS CIRCUIT FUSE RATING CCC PER CONDUIT MAX AMBIENT TEMP (C) C.O.U TEMP. DERATE C.O.U CONDUIT FILL DERATE 75°C AMPACITY COMPLIES WITH 690.8(B)(1) 90°C AMPACITY WITH C.O.U COMPLIES WITH 690.8(B)(2) FAULT CURRENT FROM PARALLEL STRINGS COMPLIES WITH 690.9(A) GROUNDING PER CONDUIT GROUNDING ³EMT RMC PVC 40 PVC 80 DC-4.1.1 CU #8 THWN2 15 18.75 NONE 6 38 91%80%50 YES 40.0 YES 30 YES 3 CU #10 1"1"1"1 1/4" DC-4.2.2 CU #10 THWN2 15 18.75 NONE 4 38 91%80%35 YES 29.1 YES 15 YES 2 CU #10 3/4"3/4"3/4"3/4" LINE SIDE TAP VIA POLARIS TAPS (POINT OF INTERCONNECTION) SCE METER 1. PV MODULES (70) QCELLS NORTH AMERICA Q.PEAK DUO BLK ML-G10.C+ 410 2. (70) SOLAREDGE DC OPTIMIZER U650 3. DC PV AND ESS CONNECTION UNIT W/ INTEGRAL LOAD BREAK DISCONNECT 4. 4A: (1) SOLAREDGE SE11400H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM], 11,400W, 240VAC, 1ø, 3W 4B: (1) SOLAREDGE SE7600H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM], 7,600W, 240VAC, 1ø, 3W 5. (N) REVENUE GRADE METER, 1ø, INTERGRATED RGM, W/ NOT REQUIRED CTS 6. (1) LOAD CENTER, 100A, 1ø, MIN.240VAC, MIN. 10KAIC, NEMA 3R 7. NOT USED 8.(N) ACDS-2 SYSTEM AC DISCONNECT SWITCH, SQUARE D, VHU363RB, 600V RATED, 240V OPERATIONAL, 100A, 3 POLE, NON-FUSIBLE, NEMA 3R. SEE REFERENCE SHEETS FOR KAIC RATING. 9. (N) SCE PV PRODUCTION METER SOCKET ADDRESS: 1233 E WILSHIRE AVE UNIT# MTR01, COOPER B-LINE, 114TB, 100A, SERVICE: 1 PHASE 3 WIRE 120/240 VAC, # JAW, NEMA 3R, EUSERC: 304 10. (N) ACDS-1 SYSTEM UTILITY AC DISCONNECT SWITCH, SQUARE D, VH223NRB, 240V RATED, 240V OPERATIONAL, 100A, 2 POLE, FUSIBLE, NEMA 3R, OR EQUIVALENT ON THE UTILITIES APPROVED LIST. CLASS J FUSE, 200KAIC RATING. 11. (E) MAIN SERVICE EQUIPMENT: 1 PHASE 3 WIRE 120/240 VAC, 150A 12. (N) CELL-B-R05-US-S-S2 CELL CARD 13. (6) SOLAREDGE BAT-10K1P BATTERIES, 9.70KWH, 5,000DCW, NEMA 3R, MOUNTED TO WALL OR MANUFACTURER FLOOR MOUNT KIT 14. (N) DC SIDCONNECT SWITCH 15. (N) POLARIS BLOCKS 16. NOT USED 1.(E) MAIN SWITCHGEAR AND (N) POINT OF AC INTERCONNECTION. ALL CONNECTIONS MADE INSIDE (E) SWITCHGEAR AT OTHER THAN CIRCUIT BREAKERS OR FUSED SWITCHES LISTED FOR USE WITH THAT SWITCHGEAR SHALL BE PERFORMED FOLLOWING MANUFACTURERS INSTRUCTIONS OR BE RE-LISTED BY A NRTL. ALL TERMINATIONS OF ALUMINUM CONDUCTORS SHALL BE WITH HIGH PRESS CRIMP LUGS ONLY. WARNING LABEL DETAIL 1/E800 2.(E) UTILITY TENANT LOAD METER. UTILITY REFERENCE METER NUMBER: 222013-142908 3.(N) PV SYSTEM UTILITY AC DISCONNECT 'ACDS-1'. WARNING LABEL DETAIL 1/E810 4.(N) UTILITY BIDIRECTIONAL KWH METER. WARNING LABEL DETAIL 1/E810 5.(N) PV SYSTEM MAINTENANCE AC DISCONNECT 'ACDS-2'. WARNING LABEL DETAIL 2/E800 & 1/E810 6.NOT USED 7.(N) GRID-INTERACTIVE PV INVERTER LISTED TO UL 1741 WITH GROUND FAULT DETECTION & INTERRUPTION. WARNING LABEL DETAIL 15/E800. 8.NOT USED 9.NOT USED 10.FOR SUPPLY SIDE CONNECTIONS, A PLAQUE SHALL BE INSTALLED AT THE MAIN SERVICE DISCONNECTING DEVICE AND THE PV SYSTEM UTILITY AC DISCONNECT INDICATING THE LOCATION OF THE RESPECTIVE SERVICE DISCONNECT. WARNING LABEL DETAIL 1/E800 & 1/E810 11.NOT USED 12.CONDUCTORS RUN IN PARALLEL SHALL BE INSTALLED PER ART 310.4/310.10(G) AND 250.122 (F). 13.NOT USED 14.NEW PULL/JUNCTION BOXES. PROVIDE SERVICE LOOP IN ALL DC BRANCH CONDUCTORS SOURCED FROM ROOFTOPS, MIN LOOP RADIUS = 12X CONDUCTOR DIAMETER. 15.NOT USED 16.(N) INVERTER INTERNAL DC DISCONNECT SWITCH(ES). WARNING LABEL DETAIL 3/E800 17.NOT USED 18.(N) PV MODULE LISTED TO UL 1703. 19.EXTRA MODULES THAT ARE UNABLE TO BE PAIRED WILL HAVE THEIR OWN OPTIMIZER. 20.(N) COMMUNICATION WIRING TO FOLLOW MANUFACTURING SPECIFICATIONS. 21.DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO THE ACCEPTED MEASURE. 22.BATTERY AC OUTPUT POWER IS LIMITED TO THE CORRESPONDING INVERTER OR TOTAL BATTERIES CONNECTED TO A SINGLE INVERTER,WHICHEVER IS LOWER. 23.BATTERIES SHOULD NOT BE INSTALLED IN DIRECT SUNLIGHT OR LOCATIONS SUBJECTED TO WATER SPRAY. SPRINKLERS SHOULD BE DIVERTED WHEN NECESSARY. 24.BATTERIES CAN COMMUNICATE WIRELESSLY OR VIA RS-485 TO INVERTER. BATTERIES WITHIN 150' (IDEALLY 50') OF RESPECTIVE INVERTER CAN USE WIRELESS COMMUNICATIONS VIA SEDG HOME NETWORK CARD. 25.COMBINED PV AND BESS OUTPUT POWER IS LIMITED TO THE INVERTER AC RATING. 26.SOLAREDGE ENERGY BANK MAY BE WALL, FLOOR, OR PAD MOUNTED INDIVIDUALLY OR IN GROUPS OF (2), (3), OR (4) UTILIZING THE SOLAREDGE FLOOR MOUNT STAND. ENERGY BANK MEETS THE UNIT LEVEL PERFORMANCE CRITERIA OF UL 9540A, ALLOWING ENERGY BANK TO BE STACKED FRONT TO BACK AS LONG AS THE CLEARANCE REQUIREMENTS ARE FOLLOWED TO ALLOW FOR AIR FLOW AROUND THE UNITS. M M M M M FACILITY LOADS (E) TENANT METERS (TYP.) (N) POLARIS BLOCK - A 11101 15 200A UTILITY METER REFERENCE NUMBER: 222013-142908 SCE UTILITY GRID 240V, 1ø,3W RMC ONLY ENTRENCHED ~10' PVC-80 EMT EMT ENTRENCHED ~10' PVC-80 EMT EMT ENTRENCHED ~10' PVC-80 EMT EMT 1233 E WILSHIRE AVE E401 G BLDG 1233 GEC 1233 E WILSHIRE AVE E401 G BLDG 1233 GEC 1233 E WILSHIRE AVE ON ESS CONCRETE PAD E500 D E500 D AHJ NOTES: 1.FUSED AC DISCONNECTS MUST BE SUSE RATED WITH A MAIN BONDING JUMPER INSTALLED. CEC 230.82(6) 2.THE "GROUND" WIRE OF FUSED AC DISCONNECTS IS A GROUNDING ELECTRODE CONDUCTOR TO BE BONDED TO THE GEC SYSTEM OF THE BUILDING 3.DISCONNECTS MUST BE WITHIN RMC TO THE POI. THE DISCONNECT AND THE SUPPLY-SIDE POI MUST BE SEALED BY SCE. THIS IS CITY POLICY FOR SE CONDUCTORS TO MINIMIZE POWER THEFT AND DAMAGE. TO GEC EGCRMC ONLY RMC ONLY WEATHERHEAD - UTILITY TERMINATION POINT SCE CECTION CUSTOMER SECTION DISTANCE FROM FUSED ACD TO POI ~ 5 FT UTILITY TERMINATION POI-4 AC WIRE SCHEDULE LABEL DESTINATION NOMINAL VAC LINE SELECTION FLA FLAX1.25 OCPD PHASE CONDUCTOR NEUTRAL CONDUCTOR GROUNDING CONDUCTOR CONDUCTORS PER PHASE CONDUIT QTY 75°C AMPS 90°C AMPS 90°C AMPS W/ C.O.U C.O.U TEMP DERATE C.O.U CONDUIT FILL CIRCUIT LENGTH ²SEGMENT VD%DC/AC RATIO AFC START AFC END ⁴EMT IMC PVC 40 PVC 80 INV-4.1 LC-4.1 240 A-B 47.5 59.4 60 CU #6 CU #10 CU #10 1 1 65 75 68.3 91%100%5 0.09%151.1%3,436 3,244 3/4"3/4"3/4"3/4" INV-4.2 LC-4.1 240 A-B 31.7 39.6 40 CU #8 CU #10 CU #10 1 1 50 55 50.1 91%100%5 0.10%151.1%3,436 3,146 1/2"1/2"3/4"3/4" LC-4.1 AC-4.2 240 A-B 79.2 99.0 100 CU #3 CU #8 CU #8 1 1 100 115 104.7 91%100%10 0.16%--3,655 3,436 1"1"1"1" AC-4.2 AC-4.1 240 A-B 79.2 99.0 100 CU #3 CU #8 CU #8 1 1 100 115 104.7 91%100%10 0.16%--3,904 3,655 1"1"1"1" AC-4.1 POI-4.4 240 A-B 79.2 99.0 100 CU #3 CU #3 CU #8 1 1 100 115 104.7 91%100%5 0.08%--42,000 30,734 1"1"1"1 1/4" D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG POI-4 ONE LINE CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH E603 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #ESTAMP WILSHIRE MINNIE 1233 E WILSHIRE AVE UNIT# MTR01 APN: 014-251-49 DEVELOPER: C&C DEVELOPMENT ##KEYED NOTES#EQUIPMENT NOTES# # COMMUNICATION CAT5E 600V RATED SHIELDED CABLE. INSTALLER SHALL FOLLOW MANUFACTURES RECOMMENDATION FOR WIRE SIZING BASED ON LENGTH. CIRCUIT IDENTIFIER EQUIPMENT INDEX EQUIPMENT TYPE SYSTEM IDENTIFIER X INDICATES LETTERS # INDICATES NUMBERS XX-#.# SYSTEM SUMMARY 26.60 ACKW | 35.67 DCKW | 33.24 CECKW 25.20 BESS ACKW | 58.20 BESS KWH TOTAL FAULT CURRENTS UTILITY: 42,000A | GENERATORS: 222A DESCRIPTION OF OPERATION (DOO) 1.INVERTERS WITH ESS ARE CERTIFIED TO UL 1741 PCS CRD AND WILL HAVE EXPORT-ONLY MODES ENABLED. THEY WILL UTILIZE EXCESS PV POWER TO CHARGE THE BATTERIES AND THE BATTERIES WILL DISCHARGE DURING SET HOURS. 2.THE PRODUCER'S STORAGE DEVICE(S) WILL NOT CONSUME POWER FROM THE DISTRIBUTION PROVIDER'S DISTRIBUTION SYSTEM AT ANY TIME. 3.GRID EXPORT IS ALLOWED THROUGH NEMV METER. 4.DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO THE ACCEPTABLE MEASURE. +- 18 14 1 13 14 ES-1 (2 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 5 . 1 . A - ( 1 3 ) 4 1 0 W M O D U L E W / ( 1 3 ) U 6 5 0 O P T S . ST R - 5 . 1 . B - ( 1 3 ) 4 1 0 W M O D U L E W / ( 1 3 ) U 6 5 0 O P T S . ST R - 5 . 1 . C - ( 1 2 ) 4 1 0 W M O D U L E W / ( 1 2 ) U 6 5 0 O P T S . ES-2 DC-5.1.1 SO L A R 3 16 BA T T E R Y 7 12 4A A-B 60A INV-5.1 +- 18 14 1 13 14 ES-1 (2 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 5 . 2 . A - ( 1 3 ) 4 1 0 W M O D U L E W / ( 1 3 ) U 6 5 0 O P T S . ST R - 5 . 2 . B - ( 1 2 ) 4 1 0 W M O D U L E W / ( 1 2 ) U 6 5 0 O P T S . ES-2 DC-5.2.2 SO L A R 3 16 BA T T E R Y 7 12 4B A-B 40A INV-5.2 +- 18 14 1 13 14 ES-1 (2 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 5 . 3 . A - ( 1 3 ) 4 1 0 W M O D U L E W / ( 1 3 ) U 6 5 0 O P T S . ST R - 5 . 3 . B - ( 1 1 ) 4 1 0 W M O D U L E W / ( 1 1 ) U 6 5 0 O P T S . ES-2 DC-5.3.3 SO L A R 3 16 BA T T E R Y 7 12 4B A-B 40A INV-5.3 6 LC-5.1 6 8 5 (N) ACDS-2 SYSTEM AC DISCONNECT SWITCH,, SQUARE D, VHU364R, 600V RATED, 240V OPERATIONAL, 200A, 3 POLE, NON-FUSIBLE, NEMA 3R. VISIBLE, LOCKABLE. SEE REFERENCE SHEETS FOR KAIC RATING. AC-5.2 M9 4 (N) SCE PV PRODUCTION METER SOCKET ADDRESS: 1401 S MINNIE ST UNIT# MTR01, COOPER B-LINE, 124TB, 200 A, SERVICE 1 PHASE 3 WIRE 120/240 VAC, NEMA 3R AC-5.2 10 3 (N) ACDS-1 SYSTEM UTILITY AC DISCONNECT SWITCH, SQUARE D, VH224NR, 240V RATED, 240V OPERATIONAL, 200A, 2 POLE, FUSIBLE, NEMA 3R, OR EQUIVALENT ON THE UTILITIES APPROVED LIST. VISIBLE, LOCKABLE. CLASS J FUSE, 200KAIC RATING. A-B 150AAC-5.1 A INTERCONNECTION LOCATION NTS1401 S MINNIE ST UNIT# MTR01 POI-5 DC STRING SCHEDULE STR-A STR-B STR-C TAG DESTINATION CIRCUIT LENGTH ²VD%MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES CIRCUIT LENGTH ²VD%MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES CIRCUIT LENGTH ²VD%MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES DC-5.1.1 INV-5.1 70 0.39%410 13 U650 8 / 16¹75 0.39%410 13 U650 8 / 16¹80 0.41%410 12 U650 8 / 16¹ DC-5.2.2 INV-5.2 120 1.06%410 13 U650 8 / 16¹105 0.80%410 12 U650 8 / 16¹------------ DC-5.3.3 INV-5.3 80 0.70%410 13 U650 8 / 16¹90 0.63%410 11 U650 8 / 16¹------------ ¹ MAXIMUM STRING LENGTH IS USING MANUFACTURES EXCEPTION ² LENGTHS ARE ESTIMATED FOR CALCULATIONS, CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS AND TAKEOFFS ³ WHERE EXPOSED TO PHYSICAL DAMAGE #6 TO BE USED PER NEC 250.120(C) ⁴ AFC VALUES ARE CALCULATED BASED ON WIRE LENGTHS. LENGTHS SHOULD REMAIN GREATER THAN OR EQUAL TO THE LENGTH LISTED IN THE TABLE. POI-5 DC WIRE SCHEDULE TAG WIRE GAUGE CONDUCTOR JACKET MAX ISC 1.25 X MAX CIRCUIT AMPS CIRCUIT FUSE RATING CCC PER CONDUIT MAX AMBIENT TEMP (C) C.O.U TEMP. DERATE C.O.U CONDUIT FILL DERATE 75°C AMPACITY COMPLIES WITH 690.8(B)(1) 90°C AMPACITY WITH C.O.U COMPLIES WITH 690.8(B)(2) FAULT CURRENT FROM PARALLEL STRINGS COMPLIES WITH 690.9(A) GROUNDING PER CONDUIT GROUNDING ³EMT RMC PVC 40 PVC 80 DC-5.1.1 CU #8 THWN2 15 18.75 NONE 6 38 91%80%50 YES 40.0 YES 30 YES 3 CU #10 1"1"1"1 1/4" DC-5.2.2 CU #10 THWN2 15 18.75 NONE 4 38 91%80%35 YES 29.1 YES 15 YES 2 CU #10 3/4"3/4"3/4"3/4" DC-5.3.3 CU #10 THWN2 15 18.75 NONE 4 38 91%80%35 YES 29.1 YES 15 YES 2 CU #10 3/4"3/4"3/4"3/4" LINE SIDE TAP POINT OF INTERCONNECTION USING MECHANICAL LUG CUSTOMER SECTION UTILITY SECTION (N) GLASTIC BARRIER SCE METER SCE PULL SECTION 1. PV MODULES (87) QCELLS NORTH AMERICA Q.PEAK DUO BLK ML-G10.C+ 410 2. (87) SOLAREDGE DC OPTIMIZER U650 3. DC PV AND ESS CONNECTION UNIT W/ INTEGRAL LOAD BREAK DISCONNECT 4. 4A: (1) SOLAREDGE SE11400H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM], 11,400W, 240VAC, 1ø, 3W 4B: (2) SOLAREDGE SE7600H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM], 7,600W, 240VAC, 1ø, 3W 5. (N) REVENUE GRADE METER, 1ø, INTERGRATED RGM, W/ NOT REQUIRED CTS 6. (1) LOAD CENTER, 200A, 1ø, MIN.240VAC, MIN. 10KAIC, NEMA 3R 7. NOT USED 8.(N) ACDS-2 SYSTEM AC DISCONNECT SWITCH, SQUARE D, VHU364R, 600V RATED, 240V OPERATIONAL, 200A, 3 POLE, NON-FUSIBLE, NEMA 3R. SEE REFERENCE SHEETS FOR KAIC RATING. 9. (N) SCE PV PRODUCTION METER SOCKET ADDRESS: 1401 S MINNIE ST UNIT# MTR01, COOPER B-LINE, 124TB, 200A, SERVICE: 1 PHASE 3 WIRE 120/240 VAC, # JAW, NEMA 3R, EUSERC: 305 10. (N) ACDS-1 SYSTEM UTILITY AC DISCONNECT SWITCH, SQUARE D, VH224NR, 240V RATED, 240V OPERATIONAL, 200A, 2 POLE, FUSIBLE, NEMA 3R, OR EQUIVALENT ON THE UTILITIES APPROVED LIST. CLASS J FUSE, 200KAIC RATING. 11. (E) MAIN SERVICE EQUIPMENT: 1 PHASE 3 WIRE 120/240 VAC, 200A 12. (N) CELL-B-R05-US-S-S2 CELL CARD 13. (6) SOLAREDGE BAT-10K1P BATTERIES, 9.70KWH, 5,000DCW, NEMA 3R, MOUNTED TO WALL OR MANUFACTURER FLOOR MOUNT KIT 14. NOT USED 15. NOT USED 16. NOT USED 1.(E) MAIN SWITCHGEAR AND (N) POINT OF AC INTERCONNECTION. ALL CONNECTIONS MADE INSIDE (E) SWITCHGEAR AT OTHER THAN CIRCUIT BREAKERS OR FUSED SWITCHES LISTED FOR USE WITH THAT SWITCHGEAR SHALL BE PERFORMED FOLLOWING MANUFACTURERS INSTRUCTIONS OR BE RE-LISTED BY A NRTL. ALL TERMINATIONS OF ALUMINUM CONDUCTORS SHALL BE WITH HIGH PRESS CRIMP LUGS ONLY. WARNING LABEL DETAIL 1/E800 2.(E) UTILITY TENANT LOAD METER. UTILITY REFERENCE METER NUMBER: 222012-825599 3.(N) PV SYSTEM UTILITY AC DISCONNECT 'ACDS-1'. WARNING LABEL DETAIL 1/E810 4.(N) UTILITY BIDIRECTIONAL KWH METER. WARNING LABEL DETAIL 1/E810 5.(N) PV SYSTEM MAINTENANCE AC DISCONNECT 'ACDS-2'. WARNING LABEL DETAIL 2/E800 & 1/E810 6.NOT USED 7.(N) GRID-INTERACTIVE PV INVERTER LISTED TO UL 1741 WITH GROUND FAULT DETECTION & INTERRUPTION. WARNING LABEL DETAIL 15/E800. 8.NOT USED 9.NOT USED 10.FOR SUPPLY SIDE CONNECTIONS, A PLAQUE SHALL BE INSTALLED AT THE MAIN SERVICE DISCONNECTING DEVICE AND THE PV SYSTEM UTILITY AC DISCONNECT INDICATING THE LOCATION OF THE RESPECTIVE SERVICE DISCONNECT. WARNING LABEL DETAIL 1/E800 & 1/E810 11.NOT USED 12.CONDUCTORS RUN IN PARALLEL SHALL BE INSTALLED PER ART 310.4/310.10(G) AND 250.122 (F). 13.NOT USED 14.NEW PULL/JUNCTION BOXES. PROVIDE SERVICE LOOP IN ALL DC BRANCH CONDUCTORS SOURCED FROM ROOFTOPS, MIN LOOP RADIUS = 12X CONDUCTOR DIAMETER. 15.NOT USED 16.(N) INVERTER INTERNAL DC DISCONNECT SWITCH(ES). WARNING LABEL DETAIL 3/E800 17.NOT USED 18.(N) PV MODULE LISTED TO UL 1703. 19.EXTRA MODULES THAT ARE UNABLE TO BE PAIRED WILL HAVE THEIR OWN OPTIMIZER. 20.(N) COMMUNICATION WIRING TO FOLLOW MANUFACTURING SPECIFICATIONS. 21.DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO THE ACCEPTED MEASURE. 22.BATTERY AC OUTPUT POWER IS LIMITED TO THE CORRESPONDING INVERTER OR TOTAL BATTERIES CONNECTED TO A SINGLE INVERTER,WHICHEVER IS LOWER. 23.BATTERIES SHOULD NOT BE INSTALLED IN DIRECT SUNLIGHT OR LOCATIONS SUBJECTED TO WATER SPRAY. SPRINKLERS SHOULD BE DIVERTED WHEN NECESSARY. 24.BATTERIES CAN COMMUNICATE WIRELESSLY OR VIA RS-485 TO INVERTER. BATTERIES WITHIN 150' (IDEALLY 50') OF RESPECTIVE INVERTER CAN USE WIRELESS COMMUNICATIONS VIA SEDG HOME NETWORK CARD. 25.COMBINED PV AND BESS OUTPUT POWER IS LIMITED TO THE INVERTER AC RATING. 26.SOLAREDGE ENERGY BANK MAY BE WALL, FLOOR, OR PAD MOUNTED INDIVIDUALLY OR IN GROUPS OF (2), (3), OR (4) UTILIZING THE SOLAREDGE FLOOR MOUNT STAND. ENERGY BANK MEETS THE UNIT LEVEL PERFORMANCE CRITERIA OF UL 9540A, ALLOWING ENERGY BANK TO BE STACKED FRONT TO BACK AS LONG AS THE CLEARANCE REQUIREMENTS ARE FOLLOWED TO ALLOW FOR AIR FLOW AROUND THE UNITS. E401 G BLDG 1401 GEC E500 D E401 G BLDG 1401 GEC E500 D E401 G BLDG 1401 GEC E500 D M M M M M FACILITY LOADS (E) TENANT METERS (TYP.) - A 11101 UTILITY METER REFERENCE NUMBER: 222012-825599 SCE UTILITY GRID 240V, 1ø,3W RMC ONLY (N) LUGS ON (E) HOLES CUSTOMER SECTION UTILITY SECTION AHJ NOTES: 1.FUSED AC DISCONNECTS MUST BE SUSE RATED WITH A MAIN BONDING JUMPER INSTALLED. CEC 230.82(6) 2.THE "GROUND" WIRE OF FUSED AC DISCONNECTS IS A GROUNDING ELECTRODE CONDUCTOR TO BE BONDED TO THE GEC SYSTEM OF THE BUILDING 3.DISCONNECTS MUST BE WITHIN RMC TO THE POI. THE DISCONNECT AND THE SUPPLY-SIDE POI MUST BE SEALED BY SCE. THIS IS CITY POLICY FOR SE CONDUCTORS TO MINIMIZE POWER THEFT AND DAMAGE. TO GEC EGCRMC ONLY RMC ONLY DISTANCE FROM FUSED ACD TO POI ~ 10 FT UTILITY TERMINATION POI-5 AC WIRE SCHEDULE LABEL DESTINATION NOMINAL VAC LINE SELECTION FLA FLAX1.25 OCPD PHASE CONDUCTOR NEUTRAL CONDUCTOR GROUNDING CONDUCTOR CONDUCTORS PER PHASE CONDUIT QTY 75°C AMPS 90°C AMPS 90°C AMPS W/ C.O.U C.O.U TEMP DERATE C.O.U CONDUIT FILL CIRCUIT LENGTH ²SEGMENT VD%DC/AC RATIO AFC START AFC END ⁴EMT IMC PVC 40 PVC 80 INV-5.1 LC-5.1 240 A-B 47.5 59.4 60 CU #6 CU #10 CU #10 1 1 65 75 68.3 91%100%5 0.09%136.7%4,784 4,421 3/4"3/4"3/4"3/4" INV-5.2 LC-5.1 240 A-B 31.7 39.6 40 CU #8 CU #10 CU #10 1 1 50 55 50.1 91%100%5 0.10%134.9%4,784 4,241 1/2"1/2"3/4"3/4" INV-5.3 LC-5.1 240 A-B 31.7 39.6 40 CU #8 CU #10 CU #10 1 1 50 55 50.1 91%100%5 0.10%129.5%4,784 4,241 1/2"1/2"3/4"3/4" LC-5.1 AC-5.2 240 A-B 110.8 138.5 150 CU #1/0 CU #6 CU #6 1 1 150 170 154.7 91%100%10 0.11%--5,008 4,784 1 1/4"1 1/4"1 1/4"1 1/4" AC-5.2 AC-5.1 240 A-B 110.8 138.5 150 CU #1/0 CU #6 CU #6 1 1 150 170 154.7 91%100%10 0.11%--5,253 5,008 1 1/4"1 1/4"1 1/4"1 1/4" AC-5.1 POI-5.5 240 A-B 110.8 138.5 150 CU #1/0 CU #1/0 CU #6 1 1 150 170 154.7 91%100%5 0.05%--42,000 35,115 1 1/2"1 1/4"1 1/2"1 1/2" D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG POI-5 ONE LINE CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH E604 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #ESTAMP WILSHIRE MINNIE 1401 S MINNIE ST UNIT# MTR01 APN: 014-251-49 DEVELOPER: C&C DEVELOPMENT ##KEYED NOTES#EQUIPMENT NOTES# # COMMUNICATION CAT5E 600V RATED SHIELDED CABLE. INSTALLER SHALL FOLLOW MANUFACTURES RECOMMENDATION FOR WIRE SIZING BASED ON LENGTH. CIRCUIT IDENTIFIER EQUIPMENT INDEX EQUIPMENT TYPE SYSTEM IDENTIFIER X INDICATES LETTERS # INDICATES NUMBERS XX-#.# SYSTEM SUMMARY 15.20 ACKW | 22.96 DCKW | 21.39 CECKW 15.20 BESS ACKW | 58.20 BESS KWH TOTAL FAULT CURRENTS UTILITY: 42,000A | GENERATORS: 148A DESCRIPTION OF OPERATION (DOO) 1.INVERTERS WITH ESS ARE CERTIFIED TO UL 1741 PCS CRD AND WILL HAVE EXPORT-ONLY MODES ENABLED. THEY WILL UTILIZE EXCESS PV POWER TO CHARGE THE BATTERIES AND THE BATTERIES WILL DISCHARGE DURING SET HOURS. 2.THE PRODUCER'S STORAGE DEVICE(S) WILL NOT CONSUME POWER FROM THE DISTRIBUTION PROVIDER'S DISTRIBUTION SYSTEM AT ANY TIME. 3.GRID EXPORT IS ALLOWED THROUGH NEMV METER. 4.DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO THE ACCEPTABLE MEASURE. +- 18 14 1 13 14 ES-1 (3 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 6 . 1 . A - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . ST R - 6 . 1 . B - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . ES-2 DC-6.1.1 SO L A R 3 16 BA T T E R Y 7 12 4 A-B 40A INV-6.1 +- 18 14 1 13 14 ES-1 (3 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 6 . 2 . A - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . ST R - 6 . 2 . B - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . ES-2 DC-6.2.2 SO L A R 3 16 BA T T E R Y 7 12 4 A-B 40A INV-6.2 6 LC-6.1 6 8 5 (N) ACDS-2 SYSTEM AC DISCONNECT SWITCH,, SQUARE D, VHU363RB, 600V RATED, 240V OPERATIONAL, 100A, 3 POLE, NON-FUSIBLE, NEMA 3R. VISIBLE, LOCKABLE. SEE REFERENCE SHEETS FOR KAIC RATING. AC-6.2 M9 4 (N) SCE PV PRODUCTION METER SOCKET ADDRESS: 1403 S MINNIE ST UNIT# MTR01, COOPER B-LINE, 114TB, 100 A, SERVICE 1 PHASE 3 WIRE 120/240 VAC, NEMA 3R AC-6.2 10 3 (N) ACDS-1 SYSTEM UTILITY AC DISCONNECT SWITCH, SQUARE D, VH223NRB, 240V RATED, 240V OPERATIONAL, 100A, 2 POLE, FUSIBLE, NEMA 3R, OR EQUIVALENT ON THE UTILITIES APPROVED LIST. VISIBLE, LOCKABLE. CLASS J FUSE, 200KAIC RATING. A-B 80AAC-6.1 A INTERCONNECTION LOCATION NTS1403 S MINNIE ST UNIT# MTR01 POI-6 DC STRING SCHEDULE STR-A STR-B TAG DESTINATION CIRCUIT LENGTH ²VD%MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES CIRCUIT LENGTH ²VD%MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES DC-6.1.1 INV-6.1 75 0.71%410 14 U650 8 / 16¹80 0.71%410 14 U650 8 / 16¹ DC-6.2.2 INV-6.2 85 0.81%410 14 U650 8 / 16¹50 0.45%410 14 U650 8 / 16¹ ¹ MAXIMUM STRING LENGTH IS USING MANUFACTURES EXCEPTION ² LENGTHS ARE ESTIMATED FOR CALCULATIONS, CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS AND TAKEOFFS ³ WHERE EXPOSED TO PHYSICAL DAMAGE #6 TO BE USED PER NEC 250.120(C) ⁴ AFC VALUES ARE CALCULATED BASED ON WIRE LENGTHS. LENGTHS SHOULD REMAIN GREATER THAN OR EQUAL TO THE LENGTH LISTED IN THE TABLE. POI-6 DC WIRE SCHEDULE TAG WIRE GAUGE CONDUCTOR JACKET MAX ISC 1.25 X MAX CIRCUIT AMPS CIRCUIT FUSE RATING CCC PER CONDUIT MAX AMBIENT TEMP (C) C.O.U TEMP. DERATE C.O.U CONDUIT FILL DERATE 75°C AMPACITY COMPLIES WITH 690.8(B)(1) 90°C AMPACITY WITH C.O.U COMPLIES WITH 690.8(B)(2) FAULT CURRENT FROM PARALLEL STRINGS COMPLIES WITH 690.9(A) GROUNDING PER CONDUIT GROUNDING ³EMT RMC PVC 40 PVC 80 DC-6.1.1 CU #10 THWN2 15 18.75 NONE 4 38 91%80%35 YES 29.1 YES 15 YES 2 CU #10 3/4"3/4"3/4"3/4" DC-6.2.2 CU #10 THWN2 15 18.75 NONE 4 38 91%80%35 YES 29.1 YES 15 YES 2 CU #10 3/4"3/4"3/4"3/4" LINE SIDE TAP VIA POLARIS TAPS (POINT OF INTERCONNECTION) SCE METER 1. PV MODULES (56) QCELLS NORTH AMERICA Q.PEAK DUO BLK ML-G10.C+ 410 2. (56) SOLAREDGE DC OPTIMIZER U650 3. DC PV AND ESS CONNECTION UNIT W/ INTEGRAL LOAD BREAK DISCONNECT 4. (2) SOLAREDGE SE7600H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM], 7,600W, 240VAC, 1ø, 3W 5. (N) REVENUE GRADE METER, 1ø, INTERGRATED RGM, W/ NOT REQUIRED CTS 6. (1) LOAD CENTER, 100A, 1ø, MIN.240VAC, MIN. 10KAIC, NEMA 3R 7. NOT USED 8.(N) ACDS-2 SYSTEM AC DISCONNECT SWITCH, SQUARE D, VHU363RB, 600V RATED, 240V OPERATIONAL, 100A, 3 POLE, NON-FUSIBLE, NEMA 3R. SEE REFERENCE SHEETS FOR KAIC RATING. 9. (N) SCE PV PRODUCTION METER SOCKET ADDRESS: 1403 S MINNIE ST UNIT# MTR01, COOPER B-LINE, 114TB, 100A, SERVICE: 1 PHASE 3 WIRE 120/240 VAC, # JAW, NEMA 3R, EUSERC: 304 10. (N) ACDS-1 SYSTEM UTILITY AC DISCONNECT SWITCH, SQUARE D, VH223NRB, 240V RATED, 240V OPERATIONAL, 100A, 2 POLE, FUSIBLE, NEMA 3R, OR EQUIVALENT ON THE UTILITIES APPROVED LIST. CLASS J FUSE, 200KAIC RATING. 11. (E) MAIN SERVICE EQUIPMENT: 1 PHASE 3 WIRE 120/240 VAC, 100A 12. (N) CELL-B-R05-US-S-S2 CELL CARD 13. (6) SOLAREDGE BAT-10K1P BATTERIES, 9.70KWH, 5,000DCW, NEMA 3R, MOUNTED TO WALL OR MANUFACTURER FLOOR MOUNT KIT 14. NOT USED 15. (N) POLARIS BLOCKS 16. NOT USED 1.(E) MAIN SWITCHGEAR AND (N) POINT OF AC INTERCONNECTION. ALL CONNECTIONS MADE INSIDE (E) SWITCHGEAR AT OTHER THAN CIRCUIT BREAKERS OR FUSED SWITCHES LISTED FOR USE WITH THAT SWITCHGEAR SHALL BE PERFORMED FOLLOWING MANUFACTURERS INSTRUCTIONS OR BE RE-LISTED BY A NRTL. ALL TERMINATIONS OF ALUMINUM CONDUCTORS SHALL BE WITH HIGH PRESS CRIMP LUGS ONLY. WARNING LABEL DETAIL 1/E800 2.(E) UTILITY TENANT LOAD METER. UTILITY REFERENCE METER NUMBER: 222013-048110 3.(N) PV SYSTEM UTILITY AC DISCONNECT 'ACDS-1'. WARNING LABEL DETAIL 1/E810 4.(N) UTILITY BIDIRECTIONAL KWH METER. WARNING LABEL DETAIL 1/E810 5.(N) PV SYSTEM MAINTENANCE AC DISCONNECT 'ACDS-2'. WARNING LABEL DETAIL 2/E800 & 1/E810 6.NOT USED 7.(N) GRID-INTERACTIVE PV INVERTER LISTED TO UL 1741 WITH GROUND FAULT DETECTION & INTERRUPTION. WARNING LABEL DETAIL 15/E800. 8.NOT USED 9.NOT USED 10.FOR SUPPLY SIDE CONNECTIONS, A PLAQUE SHALL BE INSTALLED AT THE MAIN SERVICE DISCONNECTING DEVICE AND THE PV SYSTEM UTILITY AC DISCONNECT INDICATING THE LOCATION OF THE RESPECTIVE SERVICE DISCONNECT. WARNING LABEL DETAIL 1/E800 & 1/E810 11.NOT USED 12.CONDUCTORS RUN IN PARALLEL SHALL BE INSTALLED PER ART 310.4/310.10(G) AND 250.122 (F). 13.NOT USED 14.NEW PULL/JUNCTION BOXES. PROVIDE SERVICE LOOP IN ALL DC BRANCH CONDUCTORS SOURCED FROM ROOFTOPS, MIN LOOP RADIUS = 12X CONDUCTOR DIAMETER. 15.NOT USED 16.(N) INVERTER INTERNAL DC DISCONNECT SWITCH(ES). WARNING LABEL DETAIL 3/E800 17.NOT USED 18.(N) PV MODULE LISTED TO UL 1703. 19.EXTRA MODULES THAT ARE UNABLE TO BE PAIRED WILL HAVE THEIR OWN OPTIMIZER. 20.(N) COMMUNICATION WIRING TO FOLLOW MANUFACTURING SPECIFICATIONS. 21.DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO THE ACCEPTED MEASURE. 22.BATTERY AC OUTPUT POWER IS LIMITED TO THE CORRESPONDING INVERTER OR TOTAL BATTERIES CONNECTED TO A SINGLE INVERTER,WHICHEVER IS LOWER. 23.BATTERIES SHOULD NOT BE INSTALLED IN DIRECT SUNLIGHT OR LOCATIONS SUBJECTED TO WATER SPRAY. SPRINKLERS SHOULD BE DIVERTED WHEN NECESSARY. 24.BATTERIES CAN COMMUNICATE WIRELESSLY OR VIA RS-485 TO INVERTER. BATTERIES WITHIN 150' (IDEALLY 50') OF RESPECTIVE INVERTER CAN USE WIRELESS COMMUNICATIONS VIA SEDG HOME NETWORK CARD. 25.COMBINED PV AND BESS OUTPUT POWER IS LIMITED TO THE INVERTER AC RATING. 26.SOLAREDGE ENERGY BANK MAY BE WALL, FLOOR, OR PAD MOUNTED INDIVIDUALLY OR IN GROUPS OF (2), (3), OR (4) UTILIZING THE SOLAREDGE FLOOR MOUNT STAND. ENERGY BANK MEETS THE UNIT LEVEL PERFORMANCE CRITERIA OF UL 9540A, ALLOWING ENERGY BANK TO BE STACKED FRONT TO BACK AS LONG AS THE CLEARANCE REQUIREMENTS ARE FOLLOWED TO ALLOW FOR AIR FLOW AROUND THE UNITS. M M M M M FACILITY LOADS (E) TENANT METERS (TYP.) (N) POLARIS BLOCK - A 11101 15 100A UTILITY METER REFERENCE NUMBER: 222013-048110 SCE UTILITY GRID 240V, 1ø,3W RMC ONLY E401 G BLDG 1403 GEC E500 D E401 G BLDG 1403 GEC E500 D AHJ NOTES: 1.FUSED AC DISCONNECTS MUST BE SUSE RATED WITH A MAIN BONDING JUMPER INSTALLED. CEC 230.82(6) 2.THE "GROUND" WIRE OF FUSED AC DISCONNECTS IS A GROUNDING ELECTRODE CONDUCTOR TO BE BONDED TO THE GEC SYSTEM OF THE BUILDING 3.DISCONNECTS MUST BE WITHIN RMC TO THE POI. THE DISCONNECT AND THE SUPPLY-SIDE POI MUST BE SEALED BY SCE. THIS IS CITY POLICY FOR SE CONDUCTORS TO MINIMIZE POWER THEFT AND DAMAGE. TO GEC EGCRMC ONLY RMC ONLY WEATHERHEAD - UTILITY TERMINATION POINT SCE CECTION CUSTOMER SECTION DISTANCE FROM FUSED ACD TO POI ~ 5 FT UTILITY TERMINATION POI-6 AC WIRE SCHEDULE LABEL DESTINATION NOMINAL VAC LINE SELECTION FLA FLAX1.25 OCPD PHASE CONDUCTOR NEUTRAL CONDUCTOR GROUNDING CONDUCTOR CONDUCTORS PER PHASE CONDUIT QTY 75°C AMPS 90°C AMPS 90°C AMPS W/ C.O.U C.O.U TEMP DERATE C.O.U CONDUIT FILL CIRCUIT LENGTH ²SEGMENT VD%DC/AC RATIO AFC START AFC END ⁴EMT IMC PVC 40 PVC 80 INV-6.1 LC-6.1 240 A-B 31.7 39.6 40 CU #8 CU #10 CU #10 1 1 50 55 50.1 91%100%5 0.10%151.1%2,851 2,649 1/2"1/2"3/4"3/4" INV-6.2 LC-6.1 240 A-B 31.7 39.6 40 CU #8 CU #10 CU #10 1 1 50 55 50.1 91%100%5 0.10%151.1%2,851 2,649 1/2"1/2"3/4"3/4" LC-6.1 AC-6.2 240 A-B 63.3 79.1 80 CU #4 CU #8 CU #8 1 1 85 95 86.5 91%100%10 0.16%--3,041 2,851 1"1"1"1" AC-6.2 AC-6.1 240 A-B 63.3 79.1 80 CU #4 CU #8 CU #8 1 1 85 95 86.5 91%100%10 0.16%--3,258 3,041 1"1"1"1" AC-6.1 POI-6.6 240 A-B 63.3 79.1 80 CU #4 CU #4 CU #8 1 1 85 95 86.5 91%100%5 0.08%--42,000 28,771 1"1"1"1 1/4" D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG POI-6 ONE LINE CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH E605 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #ESTAMP WILSHIRE MINNIE 1403 S MINNIE ST UNIT# MTR01 APN: 014-251-49 DEVELOPER: C&C DEVELOPMENT ##KEYED NOTES#EQUIPMENT NOTES# # COMMUNICATION CAT5E 600V RATED SHIELDED CABLE. INSTALLER SHALL FOLLOW MANUFACTURES RECOMMENDATION FOR WIRE SIZING BASED ON LENGTH. CIRCUIT IDENTIFIER EQUIPMENT INDEX EQUIPMENT TYPE SYSTEM IDENTIFIER X INDICATES LETTERS # INDICATES NUMBERS XX-#.# SYSTEM SUMMARY 19.00 ACKW | 23.37 DCKW | 21.78 CECKW 19.00 BESS ACKW | 58.20 BESS KWH TOTAL FAULT CURRENTS UTILITY: 42,000A | GENERATORS: 148A DESCRIPTION OF OPERATION (DOO) 1.INVERTERS WITH ESS ARE CERTIFIED TO UL 1741 PCS CRD AND WILL HAVE EXPORT-ONLY MODES ENABLED. THEY WILL UTILIZE EXCESS PV POWER TO CHARGE THE BATTERIES AND THE BATTERIES WILL DISCHARGE DURING SET HOURS. 2.THE PRODUCER'S STORAGE DEVICE(S) WILL NOT CONSUME POWER FROM THE DISTRIBUTION PROVIDER'S DISTRIBUTION SYSTEM AT ANY TIME. 3.GRID EXPORT IS ALLOWED THROUGH NEMV METER. 4.DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO THE ACCEPTABLE MEASURE. +- 18 14 1 13 14 ES-1 (3 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 7 . 1 . A - ( 1 2 ) 4 1 0 W M O D U L E W / ( 1 2 ) U 6 5 0 O P T S . ST R - 7 . 1 . B - ( 1 1 ) 4 1 0 W M O D U L E W / ( 1 1 ) U 6 5 0 O P T S . ST R - 7 . 1 . C - ( 1 1 ) 4 1 0 W M O D U L E W / ( 1 1 ) U 6 5 0 O P T S . ES-2 DC-7.1.1 SO L A R 3 16 BA T T E R Y 7 12 4A A-B 60A INV-7.1 +- 18 14 1 13 14 ES-1 (3 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 7 . 2 . A - ( 1 2 ) 4 1 0 W M O D U L E W / ( 1 2 ) U 6 5 0 O P T S . ST R - 7 . 2 . B - ( 1 1 ) 4 1 0 W M O D U L E W / ( 1 1 ) U 6 5 0 O P T S . ES-2 DC-7.2.2 SO L A R 3 16 BA T T E R Y 7 12 4B A-B 40A INV-7.2 6 LC-7.1 6 8 5 (N) ACDS-2 SYSTEM AC DISCONNECT SWITCH,, SQUARE D, VHU363RB, 600V RATED, 240V OPERATIONAL, 100A, 3 POLE, NON-FUSIBLE, NEMA 3R. VISIBLE, LOCKABLE. SEE REFERENCE SHEETS FOR KAIC RATING. AC-7.2 M9 4 (N) SCE PV PRODUCTION METER SOCKET ADDRESS: 1425 S MINNIE ST UNIT# MTR01, COOPER B-LINE, 114TB, 100 A, SERVICE 1 PHASE 3 WIRE 120/240 VAC, NEMA 3R AC-7.2 10 3 (N) ACDS-1 SYSTEM UTILITY AC DISCONNECT SWITCH, SQUARE D, VH223NRB, 240V RATED, 240V OPERATIONAL, 100A, 2 POLE, FUSIBLE, NEMA 3R, OR EQUIVALENT ON THE UTILITIES APPROVED LIST. VISIBLE, LOCKABLE. CLASS J FUSE, 200KAIC RATING. A-B 100AAC-7.1 A INTERCONNECTION LOCATION NTSAINTERCONNECTION LOCATION NTS1425 S MINNIE ST UNIT# MTR01 POI-7 DC STRING SCHEDULE STR-A STR-B STR-C TAG DESTINATION CIRCUIT LENGTH ²VD%MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES CIRCUIT LENGTH ²VD%MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES CIRCUIT LENGTH ²VD%MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES DC-7.1.1 INV-7.1 82 0.42%410 12 U650 8 / 16¹100 0.44%410 11 U650 8 / 16¹88 0.41%410 11 U650 8 / 16¹ DC-7.2.2 INV-7.2 60 0.49%410 12 U650 8 / 16¹60 0.42%410 11 U650 8 / 16¹------------ ¹ MAXIMUM STRING LENGTH IS USING MANUFACTURES EXCEPTION ² LENGTHS ARE ESTIMATED FOR CALCULATIONS, CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS AND TAKEOFFS ³ WHERE EXPOSED TO PHYSICAL DAMAGE #6 TO BE USED PER NEC 250.120(C) ⁴ AFC VALUES ARE CALCULATED BASED ON WIRE LENGTHS. LENGTHS SHOULD REMAIN GREATER THAN OR EQUAL TO THE LENGTH LISTED IN THE TABLE. POI-7 DC WIRE SCHEDULE TAG WIRE GAUGE CONDUCTOR JACKET MAX ISC 1.25 X MAX CIRCUIT AMPS CIRCUIT FUSE RATING CCC PER CONDUIT MAX AMBIENT TEMP (C) C.O.U TEMP. DERATE C.O.U CONDUIT FILL DERATE 75°C AMPACITY COMPLIES WITH 690.8(B)(1) 90°C AMPACITY WITH C.O.U COMPLIES WITH 690.8(B)(2) FAULT CURRENT FROM PARALLEL STRINGS COMPLIES WITH 690.9(A) GROUNDING PER CONDUIT GROUNDING ³EMT RMC PVC 40 PVC 80 DC-7.1.1 CU #8 THWN2 15 18.75 NONE 6 38 91%80%50 YES 40.0 YES 30 YES 3 CU #10 1"1"1"1 1/4" DC-7.2.2 CU #10 THWN2 15 18.75 NONE 4 38 91%80%35 YES 29.1 YES 15 YES 2 CU #10 3/4"3/4"3/4"3/4" LINE SIDE TAP VIA POLARIS TAPS (POINT OF INTERCONNECTION) SCE METER 1. PV MODULES (57) QCELLS NORTH AMERICA Q.PEAK DUO BLK ML-G10.C+ 410 2. (57) SOLAREDGE DC OPTIMIZER U650 3. DC PV AND ESS CONNECTION UNIT W/ INTEGRAL LOAD BREAK DISCONNECT 4. 4A: (1) SOLAREDGE SE11400H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM], 11,400W, 240VAC, 1ø, 3W 4B: (1) SOLAREDGE SE7600H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM], 7,600W, 240VAC, 1ø, 3W 5. (N) REVENUE GRADE METER, 1ø, INTERGRATED RGM, W/ NOT REQUIRED CTS 6. (1) LOAD CENTER, 100A, 1ø, MIN.240VAC, MIN. 10KAIC, NEMA 3R 7. NOT USED 8.(N) ACDS-2 SYSTEM AC DISCONNECT SWITCH, SQUARE D, VHU363RB, 600V RATED, 240V OPERATIONAL, 100A, 3 POLE, NON-FUSIBLE, NEMA 3R. SEE REFERENCE SHEETS FOR KAIC RATING. 9. (N) SCE PV PRODUCTION METER SOCKET ADDRESS: 1425 S MINNIE ST UNIT# MTR01, COOPER B-LINE, 114TB, 100A, SERVICE: 1 PHASE 3 WIRE 120/240 VAC, # JAW, NEMA 3R, EUSERC: 304 10. (N) ACDS-1 SYSTEM UTILITY AC DISCONNECT SWITCH, SQUARE D, VH223NRB, 240V RATED, 240V OPERATIONAL, 100A, 2 POLE, FUSIBLE, NEMA 3R, OR EQUIVALENT ON THE UTILITIES APPROVED LIST. CLASS J FUSE, 200KAIC RATING. 11. (E) MAIN SERVICE EQUIPMENT: 1 PHASE 3 WIRE 120/240 VAC, 100A 12. (N) CELL-B-R05-US-S-S2 CELL CARD 13. (6) SOLAREDGE BAT-10K1P BATTERIES, 9.70KWH, 5,000DCW, NEMA 3R, MOUNTED TO WALL OR MANUFACTURER FLOOR MOUNT KIT 14. NOT USED 15. (N) POLARIS BLOCKS 16. NOT USED 1.(E) MAIN SWITCHGEAR AND (N) POINT OF AC INTERCONNECTION. ALL CONNECTIONS MADE INSIDE (E) SWITCHGEAR AT OTHER THAN CIRCUIT BREAKERS OR FUSED SWITCHES LISTED FOR USE WITH THAT SWITCHGEAR SHALL BE PERFORMED FOLLOWING MANUFACTURERS INSTRUCTIONS OR BE RE-LISTED BY A NRTL. ALL TERMINATIONS OF ALUMINUM CONDUCTORS SHALL BE WITH HIGH PRESS CRIMP LUGS ONLY. WARNING LABEL DETAIL 1/E800 2.(E) UTILITY TENANT LOAD METER. UTILITY REFERENCE METER NUMBER: 222013-124043 3.(N) PV SYSTEM UTILITY AC DISCONNECT 'ACDS-1'. WARNING LABEL DETAIL 1/E810 4.(N) UTILITY BIDIRECTIONAL KWH METER. WARNING LABEL DETAIL 1/E810 5.(N) PV SYSTEM MAINTENANCE AC DISCONNECT 'ACDS-2'. WARNING LABEL DETAIL 2/E800 & 1/E810 6.NOT USED 7.(N) GRID-INTERACTIVE PV INVERTER LISTED TO UL 1741 WITH GROUND FAULT DETECTION & INTERRUPTION. WARNING LABEL DETAIL 15/E800. 8.NOT USED 9.NOT USED 10.FOR SUPPLY SIDE CONNECTIONS, A PLAQUE SHALL BE INSTALLED AT THE MAIN SERVICE DISCONNECTING DEVICE AND THE PV SYSTEM UTILITY AC DISCONNECT INDICATING THE LOCATION OF THE RESPECTIVE SERVICE DISCONNECT. WARNING LABEL DETAIL 1/E800 & 1/E810 11.NOT USED 12.CONDUCTORS RUN IN PARALLEL SHALL BE INSTALLED PER ART 310.4/310.10(G) AND 250.122 (F). 13.NOT USED 14.NEW PULL/JUNCTION BOXES. PROVIDE SERVICE LOOP IN ALL DC BRANCH CONDUCTORS SOURCED FROM ROOFTOPS, MIN LOOP RADIUS = 12X CONDUCTOR DIAMETER. 15.NOT USED 16.(N) INVERTER INTERNAL DC DISCONNECT SWITCH(ES). WARNING LABEL DETAIL 3/E800 17.NOT USED 18.(N) PV MODULE LISTED TO UL 1703. 19.EXTRA MODULES THAT ARE UNABLE TO BE PAIRED WILL HAVE THEIR OWN OPTIMIZER. 20.(N) COMMUNICATION WIRING TO FOLLOW MANUFACTURING SPECIFICATIONS. 21.DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO THE ACCEPTED MEASURE. 22.BATTERY AC OUTPUT POWER IS LIMITED TO THE CORRESPONDING INVERTER OR TOTAL BATTERIES CONNECTED TO A SINGLE INVERTER,WHICHEVER IS LOWER. 23.BATTERIES SHOULD NOT BE INSTALLED IN DIRECT SUNLIGHT OR LOCATIONS SUBJECTED TO WATER SPRAY. SPRINKLERS SHOULD BE DIVERTED WHEN NECESSARY. 24.BATTERIES CAN COMMUNICATE WIRELESSLY OR VIA RS-485 TO INVERTER. BATTERIES WITHIN 150' (IDEALLY 50') OF RESPECTIVE INVERTER CAN USE WIRELESS COMMUNICATIONS VIA SEDG HOME NETWORK CARD. 25.COMBINED PV AND BESS OUTPUT POWER IS LIMITED TO THE INVERTER AC RATING. 26.SOLAREDGE ENERGY BANK MAY BE WALL, FLOOR, OR PAD MOUNTED INDIVIDUALLY OR IN GROUPS OF (2), (3), OR (4) UTILIZING THE SOLAREDGE FLOOR MOUNT STAND. ENERGY BANK MEETS THE UNIT LEVEL PERFORMANCE CRITERIA OF UL 9540A, ALLOWING ENERGY BANK TO BE STACKED FRONT TO BACK AS LONG AS THE CLEARANCE REQUIREMENTS ARE FOLLOWED TO ALLOW FOR AIR FLOW AROUND THE UNITS. M M M M M FACILITY LOADS (E) TENANT METERS (TYP.) (N) POLARIS BLOCK - A 11101 15 100A UTILITY METER REFERENCE NUMBER: 222013-124043 SCE UTILITY GRID 240V, 1ø,3W RMC ONLY E401 G BLDG 1425 GEC E401 G BLDG 1425 GEC E500 D E500 D AHJ NOTES: 1.FUSED AC DISCONNECTS MUST BE SUSE RATED WITH A MAIN BONDING JUMPER INSTALLED. CEC 230.82(6) 2.THE "GROUND" WIRE OF FUSED AC DISCONNECTS IS A GROUNDING ELECTRODE CONDUCTOR TO BE BONDED TO THE GEC SYSTEM OF THE BUILDING 3.DISCONNECTS MUST BE WITHIN RMC TO THE POI. THE DISCONNECT AND THE SUPPLY-SIDE POI MUST BE SEALED BY SCE. THIS IS CITY POLICY FOR SE CONDUCTORS TO MINIMIZE POWER THEFT AND DAMAGE. TO GEC EGCRMC ONLY RMC ONLY WEATHERHEAD - UTILITY TERMINATION POINT SCE CECTION CUSTOMER SECTION DISTANCE FROM FUSED ACD TO POI ~ 5 FT UTILITY TERMINATION POI-7 AC WIRE SCHEDULE LABEL DESTINATION NOMINAL VAC LINE SELECTION FLA FLAX1.25 OCPD PHASE CONDUCTOR NEUTRAL CONDUCTOR GROUNDING CONDUCTOR CONDUCTORS PER PHASE CONDUIT QTY 75°C AMPS 90°C AMPS 90°C AMPS W/ C.O.U C.O.U TEMP DERATE C.O.U CONDUIT FILL CIRCUIT LENGTH ²SEGMENT VD%DC/AC RATIO AFC START AFC END ⁴EMT IMC PVC 40 PVC 80 INV-7.1 LC-7.1 240 A-B 47.5 59.4 60 CU #6 CU #10 CU #10 1 1 65 75 68.3 91%100%5 0.09%122.3%3,542 3,339 3/4"3/4"3/4"3/4" INV-7.2 LC-7.1 240 A-B 31.7 39.6 40 CU #8 CU #10 CU #10 1 1 50 55 50.1 91%100%5 0.10%124.1%3,542 3,235 1/2"1/2"3/4"3/4" LC-7.1 AC-7.2 240 A-B 79.2 99.0 100 CU #3 CU #8 CU #8 1 1 100 115 104.7 91%100%10 0.16%--3,775 3,542 1"1"1"1" AC-7.2 AC-7.1 240 A-B 79.2 99.0 100 CU #3 CU #8 CU #8 1 1 100 115 104.7 91%100%5 0.08%--3,904 3,775 1"1"1"1" AC-7.1 POI-7.7 240 A-B 79.2 99.0 100 CU #3 CU #3 CU #8 1 1 100 115 104.7 91%100%5 0.08%--42,000 30,734 1"1"1"1 1/4" D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG POI-7 ONE LINE CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH E606 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #ESTAMP WILSHIRE MINNIE 1425 S MINNIE ST UNIT# MTR01 APN: 014-251-50 DEVELOPER: C&C DEVELOPMENT ##KEYED NOTES#EQUIPMENT NOTES# A INTERCONNECTION LOCATION NTS COMMUNICATION CIRCUIT IDENTIFIER ##KEYED NOTES#EQUIPMENT NOTES# A INTERCONNECTION LOCATION NTS COMMUNICATION CIRCUIT IDENTIFIER SYSTEM SUMMARY 15.20 ACKW | 22.14 DCKW | 20.63 CECKW 15.20 BESS ACKW | 58.20 BESS KWH TOTAL FAULT CURRENTS UTILITY: 42,000A | GENERATORS: 156.2A + -18 14 1 13 14 ES-1 (3 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 8 . 1 . A - ( 1 3 ) 4 1 0 W M O D U L E W / ( 1 3 ) U 6 5 0 O P T S . ST R - 8 . 1 . B - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . ES-2 DC-8.1.1 SO L A R 3 16 BA T T E R Y 7 12 4 A-B 40A INV-8.1 + -18 14 1 13 14 ES-1 (3 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 8 . 2 . A - ( 1 3 ) 4 1 0 W M O D U L E W / ( 1 3 ) U 6 5 0 O P T S . ST R - 8 . 2 . B - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . ES-2 DC-8.2.2 SO L A R 3 16 BA T T E R Y 7 12 4 A-B 40A INV-8.2 6 LC-8.1 6 8 5 (N) ACDS-2 SYSTEM AC DISCONNECT SWITCH,, SQUARE D, VHU363RB, 600V RATED, 240V OPERATIONAL, 100A, 3 POLE, NON-FUSIBLE, NEMA 3R. SEE REFERENCE SHEETS FOR KAIC RATING. AC-8.2 M9 4 (N) SCE PV PRODUCTION METER SOCKET ADDRESS: 1235 E WILSHIRE AVE BLDG 1413 SOMAH8, COOPER B-LINE, 114TB, 100 A, SERVICE 1 PHASE 3 WIRE 120/240 VAC, NEMA 3R AC-8.2 10 3 (N) ACDS-1 SYSTEM UTILITY AC DISCONNECT SWITCH, SQUARE D, VH223NRB, 240V RATED, 240V OPERATIONAL, 100A, 2 POLE, FUSIBLE, NEMA 3R, OR EQUIVALENT ON THE UTILITIES APPROVED LIST. CLASS R FUSE WITH REJECTION CLIPS OR CLASS J FOR 200KAIC RATING. A-B 80AAC-8.1 1. PV MODULES (54) QCELLS NORTH AMERICA Q.PEAK DUO BLK ML-G10.C+ 410 2. (54) SOLAREDGE DC OPTIMIZER U650 3. DC PV AND ESS CONNECTION UNIT W/ INTEGRAL LOAD BREAK DISCONNECT 4. (2) SOLAREDGE SE7600H-US HOME HUB [SI1-SB], 7,600W, 240VAC, 1ø, 3W 5. (N) REVENUE GRADE METER, 1ø, INTERGRATED RGM, W/ NOT REQUIRED CTS 6. (1) LOAD CENTER, 100A, 1ø, MIN.240VAC, MIN. 22KAIC, NEMA 3R 7. NOT USED 8. (N) ACDS-2 SYSTEM AC DISCONNECT SWITCH, SQUARE D, VHU363RB, 600V RATED, 240V OPERATIONAL, 100A, 3 POLE, NON-FUSIBLE, NEMA 3R. SEE REFERENCE SHEETS FOR KAIC RATING. 9. (N) SCE PV PRODUCTION METER SOCKET ADDRESS: 1235 E WILSHIRE AVE BLDG 1413 SOMAH8, COOPER B-LINE, 114TB, 100A, SERVICE: 1 PHASE 3 WIRE 120/240 VAC, # JAW, NEMA 3R, EUSERC: 304 10. (N) ACDS-1 SYSTEM UTILITY AC DISCONNECT SWITCH, SQUARE D, VH223NRB, 240V RATED, 240V OPERATIONAL, 100A, 2 POLE, FUSIBLE, NEMA 3R, OR EQUIVALENT ON THE UTILITIES APPROVED LIST. CLASS R FUSE WITH REJECTION CLIPS OR CLASS J FOR 200KAIC RATING. 11. (E) MAIN SERVICE EQUIPMENT: 1 PHASE 3 WIRE 120/240 VAC, 100A 12. MANUFACTURER INTERGRATED CELL CARD 13. (6) SOLAREDGE BAT-10K1P BATTERIES, 9.70KWH, 5,000DCW, NEMA 3R, MOUNTED TO WALL OR MANUFACTURER FLOOR MOUNT KIT 14. NOT USED 15. (N) POLARIS BLOCKS 16. NOT USED 1. (E) MAIN SWITCHGEAR AND (N) POINT OF AC INTERCONNECTION. ALL CONNECTIONS MADE INSIDE (E) SWITCHGEAR AT OTHER THAN CIRCUIT BREAKERS OR FUSED SWITCHES LISTED FOR USE WITH THAT SWITCHGEAR SHALL BE PERFORMED FOLLOWING MANUFACTURERS INSTRUCTIONS OR BE RE-LISTED BY A NRTL. ALL TERMINATIONS OF ALUMINUM CONDUCTORS SHALL BE WITH HIGH PRESS CRIMP LUGS ONLY. WARNING LABEL DETAIL 1/E800 2. (E) UTILITY TENANT LOAD METER. UTILITY REFERENCE METER NUMBER: 222013-048131 3. (N) PV SYSTEM UTILITY AC DISCONNECT 'ACDS-1'. WARNING LABEL DETAIL 1/E810 4. (N) UTILITY BIDIRECTIONAL KWH METER. WARNING LABEL DETAIL 1/E810 5. (N) PV SYSTEM MAINTENANCE AC DISCONNECT 'ACDS-2'. WARNING LABEL DETAIL 2/E800 & 1/E810 6. NOT USED 7. (N) GRID-INTERACTIVE PV INVERTER LISTED TO UL 1741 WITH GROUND FAULT DETECTION & INTERRUPTION. WARNING LABEL DETAIL 15/E800. 8. NOT USED 9. NOT USED 10. FOR SUPPLY SIDE CONNECTIONS, A PLAQUE SHALL BE INSTALLED AT THE MAIN SERVICE DISCONNECTING DEVICE AND THE PV SYSTEM UTILITY AC DISCONNECT INDICATING THE LOCATION OF THE RESPECTIVE SERVICE DISCONNECT. WARNING LABEL DETAIL 1/E800 & 1/E810 11. NOT USED 12. CONDUCTORS RUN IN PARALLEL SHALL BE INSTALLED PER ART 310.4/310.10(G) AND 250.122 (F). 13. NOT USED 14. NEW PULL/JUNCTION BOXES. PROVIDE SERVICE LOOP IN ALL DC BRANCH CONDUCTORS SOURCED FROM ROOFTOPS, MIN LOOP RADIUS = 12X CONDUCTOR DIAMETER. 15. NOT USED 16. (N) INVERTER INTERNAL DC DISCONNECT SWITCH(ES). WARNING LABEL DETAIL 3/E800 17. NOT USED 18. (N) PV MODULE LISTED TO UL 1703. 19. EXTRA MODULES THAT ARE UNABLE TO BE PAIRED WILL HAVE THEIR OWN OPTIMIZER. 20. (N) COMMUNICATION WIRING TO FOLLOW MANUFACTURING SPECIFICATIONS. 21. DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO THE ACCEPTED MEASURE. 22. BATTERY AC OUTPUT POWER IS LIMITED TO THE CORRESPONDING INVERTER OR TOTAL BATTERIES CONNECTED TO A SINGLE INVERTER,WHICHEVER IS LOWER. 23. BATTERIES SHOULD NOT BE INSTALLED IN DIRECT SUNLIGHT OR LOCATIONS SUBJECTED TO WATER SPRAY. SPRINKLERS SHOULD BE DIVERTED WHEN NECESSARY. 24. BATTERIES CAN COMMUNICATE WIRELESSLY OR VIA RS-485 TO INVERTER. BATTERIES WITHIN 150' (IDEALLY 50') OF RESPECTIVE INVERTER CAN USE WIRELESS COMMUNICATIONS VIA SEDG HOME NETWORK CARD. 25. COMBINED PV AND BESS OUTPUT POWER IS LIMITED TO THE INVERTER AC RATING. 26. NOT USED # CAT5E 600V RATED SHIELDED CABLE. INSTALLER SHALL FOLLOW MANUFACTURES RECOMMENDATION FOR WIRE SIZING BASED ON LENGTH. EQUIPMENT TYPE SYSTEM IDENTIFIER X INDICATES LETTERS # INDICATES NUMBERS XX-#.# 1235 E WILSHIRE AVE BLDG 1413 SOMAH8 POI-8 DC STRING SCHEDULE STR-A STR-B TAG DESTINATION CIRCUIT LENGTH ²VD% MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES CIRCUIT LENGTH ²VD% MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES DC-8.1.1 INV-8.1 120 1.06%410 13 U650 8 / 16¹50 0.45%410 14 U650 8 / 16¹ DC-8.2.2 INV-8.2 95 0.84%410 13 U650 8 / 16¹95 0.85%410 14 U650 8 / 16¹ ¹ MAXIMUM STRING LENGTH IS USING MANUFACTURES EXCEPTION ² LENGTHS ARE ESTIMATED FOR CALCULATIONS, CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS AND TAKEOFFS ³ WHERE EXPOSED TO PHYSICAL DAMAGE #6 TO BE USED PER NEC 250.120(C) ⁴ AFC VALUES ARE CALCULATED BASED ON WIRE LENGTHS. LENGTHS SHOULD REMAIN GREATER THAN OR EQUAL TO THE LENGTH LISTED IN THE TABLE. POI-8 DC WIRE SCHEDULE TAG WIRE GAUGE CONDUCTOR JACKET CCC PER CONDUIT GROUNDING ³EMT RMC PVC 40 PVC 80 DC-8.1.1 CU #10 THWN2 4 CU #10 3/4"3/4"3/4"3/4" DC-8.2.2 CU #10 THWN2 4 CU #10 3/4"3/4"3/4"3/4" POI-8 AC WIRE SCHEDULE LABEL DESTINATION NOMINAL VAC LINE SELECTION FLA FLAX1.25 PHASE CONDUCTOR NEUTRAL CONDUCTOR GROUNDING CONDUCTOR CONDUCTORS PER PHASE CONDUIT QTY CIRCUIT LENGTH ² SEGMENT VD% DC/AC RATIO AFC START AFC END ⁴EMT IMC PVC 40 PVC 80 INV-8.1 LC-8.1 240 A-B 31.7 39.6 CU #8 CU #10 CU #10 1 1 5 0.10% 145.7%4,918 4,346 1/2"1/2"3/4"3/4" INV-8.2 LC-8.1 240 A-B 31.7 39.6 CU #8 CU #10 CU #10 1 1 5 0.10% 145.7%4,918 4,346 1/2"1/2"3/4"3/4" LC-8.1 AC-8.2 240 A-B 63.3 79.1 CU #4 CU #8 CU #8 1 1 70 1.10%--19,967 4,918 1"1"1"1" AC-8.2 AC-8.1 240 A-B 63.3 79.1 CU #4 CU #8 CU #8 1 1 7 0.11%--28,771 19,967 1"1"1"1" AC-8.1 POI-8.8 240 A-B 63.3 79.1 CU #4 CU #4 CU #8 1 1 5 0.08%--42,000 28,771 1"1"1"1 1/4" M M M M M FACILITY LOADS (N) TENANT METERS (TYP.) UTILITY METER REFERENCE NUMBER: 222013-048131 SCE UTILITY GRID 240V, 1ø,3W 11101 - A 15 (N) POLARIS BLOCK POLARIS SUPPLY SIDE TAP POINT OF INTERCONNECTION C:\USERS\EMILIANO.MORALES\DESKTOP\WORKING PROJECTS\1235_WILSHIRE_MINNIE\CD100\WILSHIRE MINNIE_WORKINGDOCS_V0\WILSHIRE MINNIE.DWG POI-8 ONE LINE CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 PROJECT DETAILS: PV SYSTEM: ·355.88 kW DC ·250.8 kW AC ·331.612 CEC AC ENERGY STORAGE: ·243.2 kW AC ·756.6 kWH E607 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM ORIGINAL CONTRACT NUMBER: 3003197607 PJT #: PROP-001235 ##KEYED NOTES#EQUIPMENT NOTES# A INTERCONNECTION LOCATION NTS COMMUNICATION CIRCUIT IDENTIFIER ##KEYED NOTES#EQUIPMENT NOTES# A INTERCONNECTION LOCATION NTS COMMUNICATION CIRCUIT IDENTIFIER SYSTEM SUMMARY 15.20 ACKW | 21.73 DCKW | 20.25 CECKW 15.20 BESS ACKW | 58.20 BESS KWH TOTAL FAULT CURRENTS UTILITY: 42,000A | GENERATORS: 156.2A + -18 14 1 13 14 ES-1 (3 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 9 . 1 . A - ( 1 2 ) 4 1 0 W M O D U L E W / ( 1 2 ) U 6 5 0 O P T S . ST R - 9 . 1 . B - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . ES-2 DC-9.1.1 SO L A R 3 16 BA T T E R Y 7 12 4 A-B 40A INV-9.1 + -18 14 1 13 14 ES-1 (3 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 9 . 2 . A - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . ST R - 9 . 2 . B - ( 1 3 ) 4 1 0 W M O D U L E W / ( 1 3 ) U 6 5 0 O P T S . ES-2 DC-9.2.2 SO L A R 3 16 BA T T E R Y 7 12 4 A-B 40A INV-9.2 6 LC-9.1 6 8 5 (N) ACDS-2 SYSTEM AC DISCONNECT SWITCH,, SQUARE D, VHU363RB, 600V RATED, 240V OPERATIONAL, 100A, 3 POLE, NON-FUSIBLE, NEMA 3R. SEE REFERENCE SHEETS FOR KAIC RATING. AC-9.2 M9 4 (N) SCE PV PRODUCTION METER SOCKET ADDRESS: 1235 E WILSHIRE AVE BLDG 1421 SOMAH9, COOPER B-LINE, 114TB, 100 A, SERVICE 1 PHASE 3 WIRE 120/240 VAC, NEMA 3R AC-9.2 10 3 (N) ACDS-1 SYSTEM UTILITY AC DISCONNECT SWITCH, SQUARE D, VH223NRB, 240V RATED, 240V OPERATIONAL, 100A, 2 POLE, FUSIBLE, NEMA 3R, OR EQUIVALENT ON THE UTILITIES APPROVED LIST. CLASS R FUSE WITH REJECTION CLIPS OR CLASS J FOR 200KAIC RATING. A-B 80AAC-9.1 1. PV MODULES (53) QCELLS NORTH AMERICA Q.PEAK DUO BLK ML-G10.C+ 410 2. (53) SOLAREDGE DC OPTIMIZER U650 3. DC PV AND ESS CONNECTION UNIT W/ INTEGRAL LOAD BREAK DISCONNECT 4. (2) SOLAREDGE SE7600H-US HOME HUB [SI1-SB], 7,600W, 240VAC, 1ø, 3W 5. (N) REVENUE GRADE METER, 1ø, INTERGRATED RGM, W/ NOT REQUIRED CTS 6. (1) LOAD CENTER, 100A, 1ø, MIN.240VAC, MIN. 22KAIC, NEMA 3R 7. NOT USED 8. (N) ACDS-2 SYSTEM AC DISCONNECT SWITCH, SQUARE D, VHU363RB, 600V RATED, 240V OPERATIONAL, 100A, 3 POLE, NON-FUSIBLE, NEMA 3R. SEE REFERENCE SHEETS FOR KAIC RATING. 9. (N) SCE PV PRODUCTION METER SOCKET ADDRESS: 1235 E WILSHIRE AVE BLDG 1421 SOMAH9, COOPER B-LINE, 114TB, 100A, SERVICE: 1 PHASE 3 WIRE 120/240 VAC, # JAW, NEMA 3R, EUSERC: 304 10. (N) ACDS-1 SYSTEM UTILITY AC DISCONNECT SWITCH, SQUARE D, VH223NRB, 240V RATED, 240V OPERATIONAL, 100A, 2 POLE, FUSIBLE, NEMA 3R, OR EQUIVALENT ON THE UTILITIES APPROVED LIST. CLASS R FUSE WITH REJECTION CLIPS OR CLASS J FOR 200KAIC RATING. 11. (E) MAIN SERVICE EQUIPMENT: 1 PHASE 3 WIRE 120/240 VAC, 100A 12. MANUFACTURER INTERGRATED CELL CARD 13. (6) SOLAREDGE BAT-10K1P BATTERIES, 9.70KWH, 5,000DCW, NEMA 3R, MOUNTED TO WALL OR MANUFACTURER FLOOR MOUNT KIT 14. NOT USED 15. (N) POLARIS BLOCKS 16. NOT USED 1. (E) MAIN SWITCHGEAR AND (N) POINT OF AC INTERCONNECTION. ALL CONNECTIONS MADE INSIDE (E) SWITCHGEAR AT OTHER THAN CIRCUIT BREAKERS OR FUSED SWITCHES LISTED FOR USE WITH THAT SWITCHGEAR SHALL BE PERFORMED FOLLOWING MANUFACTURERS INSTRUCTIONS OR BE RE-LISTED BY A NRTL. ALL TERMINATIONS OF ALUMINUM CONDUCTORS SHALL BE WITH HIGH PRESS CRIMP LUGS ONLY. WARNING LABEL DETAIL 1/E800 2. (E) UTILITY TENANT LOAD METER. UTILITY REFERENCE METER NUMBER: 222013-048104 3. (N) PV SYSTEM UTILITY AC DISCONNECT 'ACDS-1'. WARNING LABEL DETAIL 1/E810 4. (N) UTILITY BIDIRECTIONAL KWH METER. WARNING LABEL DETAIL 1/E810 5. (N) PV SYSTEM MAINTENANCE AC DISCONNECT 'ACDS-2'. WARNING LABEL DETAIL 2/E800 & 1/E810 6. NOT USED 7. (N) GRID-INTERACTIVE PV INVERTER LISTED TO UL 1741 WITH GROUND FAULT DETECTION & INTERRUPTION. WARNING LABEL DETAIL 15/E800. 8. NOT USED 9. NOT USED 10. FOR SUPPLY SIDE CONNECTIONS, A PLAQUE SHALL BE INSTALLED AT THE MAIN SERVICE DISCONNECTING DEVICE AND THE PV SYSTEM UTILITY AC DISCONNECT INDICATING THE LOCATION OF THE RESPECTIVE SERVICE DISCONNECT. WARNING LABEL DETAIL 1/E800 & 1/E810 11. NOT USED 12. CONDUCTORS RUN IN PARALLEL SHALL BE INSTALLED PER ART 310.4/310.10(G) AND 250.122 (F). 13. NOT USED 14. NEW PULL/JUNCTION BOXES. PROVIDE SERVICE LOOP IN ALL DC BRANCH CONDUCTORS SOURCED FROM ROOFTOPS, MIN LOOP RADIUS = 12X CONDUCTOR DIAMETER. 15. NOT USED 16. (N) INVERTER INTERNAL DC DISCONNECT SWITCH(ES). WARNING LABEL DETAIL 3/E800 17. NOT USED 18. (N) PV MODULE LISTED TO UL 1703. 19. EXTRA MODULES THAT ARE UNABLE TO BE PAIRED WILL HAVE THEIR OWN OPTIMIZER. 20. (N) COMMUNICATION WIRING TO FOLLOW MANUFACTURING SPECIFICATIONS. 21. DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO THE ACCEPTED MEASURE. 22. BATTERY AC OUTPUT POWER IS LIMITED TO THE CORRESPONDING INVERTER OR TOTAL BATTERIES CONNECTED TO A SINGLE INVERTER,WHICHEVER IS LOWER. 23. BATTERIES SHOULD NOT BE INSTALLED IN DIRECT SUNLIGHT OR LOCATIONS SUBJECTED TO WATER SPRAY. SPRINKLERS SHOULD BE DIVERTED WHEN NECESSARY. 24. BATTERIES CAN COMMUNICATE WIRELESSLY OR VIA RS-485 TO INVERTER. BATTERIES WITHIN 150' (IDEALLY 50') OF RESPECTIVE INVERTER CAN USE WIRELESS COMMUNICATIONS VIA SEDG HOME NETWORK CARD. 25. COMBINED PV AND BESS OUTPUT POWER IS LIMITED TO THE INVERTER AC RATING. 26. NOT USED # CAT5E 600V RATED SHIELDED CABLE. INSTALLER SHALL FOLLOW MANUFACTURES RECOMMENDATION FOR WIRE SIZING BASED ON LENGTH. EQUIPMENT TYPE SYSTEM IDENTIFIER X INDICATES LETTERS # INDICATES NUMBERS XX-#.# 1235 E WILSHIRE AVE BLDG 1421 SOMAH9 POI-9 DC STRING SCHEDULE STR-A STR-B TAG DESTINATION CIRCUIT LENGTH ²VD% MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES CIRCUIT LENGTH ²VD% MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES DC-9.1.1 INV-9.1 105 0.85%410 12 U650 8 / 16¹95 0.85%410 14 U650 8 / 16¹ DC-9.2.2 INV-9.2 50 0.47%410 14 U650 8 / 16¹60 0.50%410 13 U650 8 / 16¹ ¹ MAXIMUM STRING LENGTH IS USING MANUFACTURES EXCEPTION ² LENGTHS ARE ESTIMATED FOR CALCULATIONS, CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS AND TAKEOFFS ³ WHERE EXPOSED TO PHYSICAL DAMAGE #6 TO BE USED PER NEC 250.120(C) ⁴ AFC VALUES ARE CALCULATED BASED ON WIRE LENGTHS. LENGTHS SHOULD REMAIN GREATER THAN OR EQUAL TO THE LENGTH LISTED IN THE TABLE. POI-9 DC WIRE SCHEDULE TAG WIRE GAUGE CONDUCTOR JACKET CCC PER CONDUIT GROUNDING ³EMT RMC PVC 40 PVC 80 DC-9.1.1 CU #10 THWN2 4 CU #10 3/4"3/4"3/4"3/4" DC-9.2.2 CU #10 THWN2 4 CU #10 3/4"3/4"3/4"3/4" POI-9 AC WIRE SCHEDULE LABEL DESTINATION NOMINAL VAC LINE SELECTION FLA FLAX1.25 PHASE CONDUCTOR NEUTRAL CONDUCTOR GROUNDING CONDUCTOR CONDUCTORS PER PHASE CONDUIT QTY CIRCUIT LENGTH ² SEGMENT VD% DC/AC RATIO AFC START AFC END ⁴EMT IMC PVC 40 PVC 80 INV-9.1 LC-9.1 240 A-B 31.7 39.6 CU #8 CU #10 CU #10 1 1 5 0.10% 140.3%4,764 4,225 1/2"1/2"3/4"3/4" INV-9.2 LC-9.1 240 A-B 31.7 39.6 CU #8 CU #10 CU #10 1 1 5 0.10% 145.7%4,764 4,225 1/2"1/2"3/4"3/4" LC-9.1 AC-9.2 240 A-B 63.3 79.1 CU #4 CU #8 CU #8 1 1 75 1.18%--21,880 4,764 1"1"1"1" AC-9.2 AC-9.1 240 A-B 63.3 79.1 CU #4 CU #8 CU #8 1 1 5 0.08%--28,771 21,880 1"1"1"1" AC-9.1 POI-9.9 240 A-B 63.3 79.1 CU #4 CU #4 CU #8 1 1 5 0.08%--42,000 28,771 1"1"1"1 1/4" M M M M M FACILITY LOADS (N) TENANT METERS (TYP.) UTILITY METER REFERENCE NUMBER: 222013-048104 SCE UTILITY GRID 240V, 1ø,3W 11101 - A 15 (N) POLARIS BLOCK POLARIS SUPPLY SIDE TAP POINT OF INTERCONNECTION C:\USERS\EMILIANO.MORALES\DESKTOP\WORKING PROJECTS\1235_WILSHIRE_MINNIE\CD100\WILSHIRE MINNIE_WORKINGDOCS_V0\WILSHIRE MINNIE.DWG POI-8 ONE LINE CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 PROJECT DETAILS: PV SYSTEM: ·355.88 kW DC ·250.8 kW AC ·331.612 CEC AC ENERGY STORAGE: ·243.2 kW AC ·756.6 kWH E608 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM ORIGINAL CONTRACT NUMBER: 3003197607 PJT #: PROP-001235 ##KEYED NOTES#EQUIPMENT NOTES# A INTERCONNECTION LOCATION NTS COMMUNICATION CIRCUIT IDENTIFIER ##KEYED NOTES#EQUIPMENT NOTES# A INTERCONNECTION LOCATION NTS COMMUNICATION CIRCUIT IDENTIFIER SYSTEM SUMMARY 19.00 ACKW | 27.88 DCKW | 25.98 CECKW 19.00 BESS ACKW | 58.20 BESS KWH TOTAL FAULT CURRENTS UTILITY: 42,000A | GENERATORS: 156.2A + -18 14 1 13 14 ES-1 (3 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 1 0 . 1 . A - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . ST R - 1 0 . 1 . B - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . ST R - 1 0 . 1 . C - ( 1 4 ) 4 1 0 W M O D U L E W / ( 1 4 ) U 6 5 0 O P T S . ES-2 DC-10.1.1 SO L A R 3 16 BA T T E R Y 7 12 4A A-B 60A INV-10.1 + -18 14 1 13 14 ES-1 (3 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 1 0 . 2 . A - ( 8 ) 4 1 0 W M O D U L E W / ( 8 ) U 6 5 0 O P T S . ST R - 1 0 . 2 . B - ( 8 ) 4 1 0 W M O D U L E W / ( 8 ) U 6 5 0 O P T S . ST R - 1 0 . 2 . C - ( 1 0 ) 4 1 0 W M O D U L E W / ( 1 0 ) U 6 5 0 O P T S . ES-2 DC-10.2.2 SO L A R 3 16 BA T T E R Y 7 12 4B A-B 40A INV-10.2 6 LC-10.1 6 8 5 (N) ACDS-2 SYSTEM AC DISCONNECT SWITCH,, SQUARE D, VHU362RB, 600V RATED, 240V OPERATIONAL, 60A, 3 POLE, NON-FUSIBLE, NEMA 3R. SEE REFERENCE SHEETS FOR KAIC RATING. AC-10.2 M9 4 (N) SCE PV PRODUCTION METER SOCKET ADDRESS: 1235 E WILSHIRE AVE BLDG 1425 SOMAH10, COOPER B-LINE, 114TB, 100 A, SERVICE 1 PHASE 3 WIRE 120/240 VAC, NEMA 3R AC-10.2 10 3 (N) ACDS-1 SYSTEM UTILITY AC DISCONNECT SWITCH, SQUARE D, VH223NRB, 240V RATED, 240V OPERATIONAL, 100A, 2 POLE, FUSIBLE, NEMA 3R, OR EQUIVALENT ON THE UTILITIES APPROVED LIST. CLASS R FUSE WITH REJECTION CLIPS OR CLASS J FOR 200KAIC RATING. A-B 100AAC-10.1 1. PV MODULES (68) QCELLS NORTH AMERICA Q.PEAK DUO BLK ML-G10.C+ 410 2. (68) SOLAREDGE DC OPTIMIZER U650 3. DC PV AND ESS CONNECTION UNIT W/ INTEGRAL LOAD BREAK DISCONNECT 4. 4A: (1) SOLAREDGE SE11400H-US HOME HUB [SI1-SB], 11,400W, 240VAC, 1ø, 3W 4B: (1) SOLAREDGE SE7600H-US HOME HUB [SI1-SB], 7,600W, 240VAC, 1ø, 3W 5. (N) REVENUE GRADE METER, 1ø, INTERGRATED RGM, W/ NOT REQUIRED CTS 6. (1) LOAD CENTER, 100A, 1ø, MIN.240VAC, MIN. 22KAIC, NEMA 3R 7. NOT USED 8. (N) ACDS-2 SYSTEM AC DISCONNECT SWITCH, SQUARE D, VHU362RB, 600V RATED, 240V OPERATIONAL, 60A, 3 POLE, NON-FUSIBLE, NEMA 3R. SEE REFERENCE SHEETS FOR KAIC RATING. 9. (N) SCE PV PRODUCTION METER SOCKET ADDRESS: 1235 E WILSHIRE AVE BLDG 1425 SOMAH10, COOPER B-LINE, 114TB, 100A, SERVICE: 1 PHASE 3 WIRE 120/240 VAC, # JAW, NEMA 3R, EUSERC: 304 10. (N) ACDS-1 SYSTEM UTILITY AC DISCONNECT SWITCH, SQUARE D, VH223NRB, 240V RATED, 240V OPERATIONAL, 100A, 2 POLE, FUSIBLE, NEMA 3R, OR EQUIVALENT ON THE UTILITIES APPROVED LIST. CLASS R FUSE WITH REJECTION CLIPS OR CLASS J FOR 200KAIC RATING. 11. (E) MAIN SERVICE EQUIPMENT: 1 PHASE 3 WIRE 120/240 VAC, 100A 12. MANUFACTURER INTERGRATED CELL CARD 13. (6) SOLAREDGE BAT-10K1P BATTERIES, 9.70KWH, 5,000DCW, NEMA 3R, MOUNTED TO WALL OR MANUFACTURER FLOOR MOUNT KIT 14. NOT USED 15. (N) POLARIS BLOCKS 16. NOT USED 1. (E) MAIN SWITCHGEAR AND (N) POINT OF AC INTERCONNECTION. ALL CONNECTIONS MADE INSIDE (E) SWITCHGEAR AT OTHER THAN CIRCUIT BREAKERS OR FUSED SWITCHES LISTED FOR USE WITH THAT SWITCHGEAR SHALL BE PERFORMED FOLLOWING MANUFACTURERS INSTRUCTIONS OR BE RE-LISTED BY A NRTL. ALL TERMINATIONS OF ALUMINUM CONDUCTORS SHALL BE WITH HIGH PRESS CRIMP LUGS ONLY. WARNING LABEL DETAIL 1/E800 2. (E) UTILITY TENANT LOAD METER. UTILITY REFERENCE METER NUMBER: 222013-124043 3. (N) PV SYSTEM UTILITY AC DISCONNECT 'ACDS-1'. WARNING LABEL DETAIL 1/E810 4. (N) UTILITY BIDIRECTIONAL KWH METER. WARNING LABEL DETAIL 1/E810 5. (N) PV SYSTEM MAINTENANCE AC DISCONNECT 'ACDS-2'. WARNING LABEL DETAIL 2/E800 & 1/E810 6. NOT USED 7. (N) GRID-INTERACTIVE PV INVERTER LISTED TO UL 1741 WITH GROUND FAULT DETECTION & INTERRUPTION. WARNING LABEL DETAIL 15/E800. 8. NOT USED 9. NOT USED 10. FOR SUPPLY SIDE CONNECTIONS, A PLAQUE SHALL BE INSTALLED AT THE MAIN SERVICE DISCONNECTING DEVICE AND THE PV SYSTEM UTILITY AC DISCONNECT INDICATING THE LOCATION OF THE RESPECTIVE SERVICE DISCONNECT. WARNING LABEL DETAIL 1/E800 & 1/E810 11. NOT USED 12. CONDUCTORS RUN IN PARALLEL SHALL BE INSTALLED PER ART 310.4/310.10(G) AND 250.122 (F). 13. NOT USED 14. NEW PULL/JUNCTION BOXES. PROVIDE SERVICE LOOP IN ALL DC BRANCH CONDUCTORS SOURCED FROM ROOFTOPS, MIN LOOP RADIUS = 12X CONDUCTOR DIAMETER. 15. NOT USED 16. (N) INVERTER INTERNAL DC DISCONNECT SWITCH(ES). WARNING LABEL DETAIL 3/E800 17. NOT USED 18. (N) PV MODULE LISTED TO UL 1703. 19. EXTRA MODULES THAT ARE UNABLE TO BE PAIRED WILL HAVE THEIR OWN OPTIMIZER. 20. (N) COMMUNICATION WIRING TO FOLLOW MANUFACTURING SPECIFICATIONS. 21. DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO THE ACCEPTED MEASURE. 22. BATTERY AC OUTPUT POWER IS LIMITED TO THE CORRESPONDING INVERTER OR TOTAL BATTERIES CONNECTED TO A SINGLE INVERTER,WHICHEVER IS LOWER. 23. BATTERIES SHOULD NOT BE INSTALLED IN DIRECT SUNLIGHT OR LOCATIONS SUBJECTED TO WATER SPRAY. SPRINKLERS SHOULD BE DIVERTED WHEN NECESSARY. 24. BATTERIES CAN COMMUNICATE WIRELESSLY OR VIA RS-485 TO INVERTER. BATTERIES WITHIN 150' (IDEALLY 50') OF RESPECTIVE INVERTER CAN USE WIRELESS COMMUNICATIONS VIA SEDG HOME NETWORK CARD. 25. COMBINED PV AND BESS OUTPUT POWER IS LIMITED TO THE INVERTER AC RATING. 26. NOT USED # CAT5E 600V RATED SHIELDED CABLE. INSTALLER SHALL FOLLOW MANUFACTURES RECOMMENDATION FOR WIRE SIZING BASED ON LENGTH. EQUIPMENT TYPE SYSTEM IDENTIFIER X INDICATES LETTERS # INDICATES NUMBERS XX-#.# 1235 E WILSHIRE AVE BLDG 1425 SOMAH10 POI-10 DC STRING SCHEDULE STR-A STR-B STR-C TAG DESTINATION CIRCUIT LENGTH ² VD% MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES CIRCUIT LENGTH ² VD% MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES CIRCUIT LENGTH ² VD% MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES DC-10.1.1 INV-10.1 110 0.65%410 14 U650 8 / 16¹110 0.62%410 14 U650 8 / 16¹100 0.59%410 14 U650 8 / 16¹ DC-10.2.2 INV-10.2 90 0.31%410 8 U650 8 / 16¹70 0.22%410 8 U650 8 / 16¹50 0.21%410 10 U650 8 / 16¹ ¹ MAXIMUM STRING LENGTH IS USING MANUFACTURES EXCEPTION ² LENGTHS ARE ESTIMATED FOR CALCULATIONS, CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS AND TAKEOFFS ³ WHERE EXPOSED TO PHYSICAL DAMAGE #6 TO BE USED PER NEC 250.120(C) ⁴ AFC VALUES ARE CALCULATED BASED ON WIRE LENGTHS. LENGTHS SHOULD REMAIN GREATER THAN OR EQUAL TO THE LENGTH LISTED IN THE TABLE. POI-10 DC WIRE SCHEDULE TAG WIRE GAUGE CONDUCTOR JACKET CCC PER CONDUIT GROUNDING ³EMT RMC PVC 40 PVC 80 DC-10.1.1 CU #8 THWN2 6 CU #10 1"1"1"1 1/4" DC-10.2.2 CU #8 THWN2 6 CU #10 1"1"1"1 1/4" POI-10 AC WIRE SCHEDULE LABEL DESTINATION NOMINAL VAC LINE SELECTION FLA FLAX1.25 PHASE CONDUCTOR NEUTRAL CONDUCTOR GROUNDING CONDUCTOR CONDUCTORS PER PHASE CONDUIT QTY CIRCUIT LENGTH ² SEGMENT VD% DC/AC RATIO AFC START AFC END ⁴EMT IMC PVC 40 PVC 80 INV-10.1 LC-10.1 240 A-B 47.5 59.4 CU #6 CU #10 CU #10 1 1 5 0.09% 151.1%6,463 5,817 3/4"3/4"3/4"3/4" INV-10.2 LC-10.1 240 A-B 31.7 39.6 CU #8 CU #10 CU #10 1 1 5 0.10% 140.3% 6,463 5,510 1/2"1/2"3/4"3/4" LC-10.1 AC-10.1 240 A-B 79.2 99.0 CU #3 CU #8 CU #8 1 1 70 1.11%--30,734 6,463 1"1"1"1" AC-10.2 AC-10.1 240 0.0 0.0 CU #14 CU #14 CU #10 1 1 5 0.00%--30,734 7,161 1/2"1/2"1/2"1/2" AC-10.1 POI-10.10 240 A-B 79.2 99.0 CU #3 CU #3 CU #8 1 1 5 0.08%--42,000 30,734 1"1"1"1 1/4" M M M M M FACILITY LOADS (N) TENANT METERS (TYP.) UTILITY METER REFERENCE NUMBER: 222013-124043 SCE UTILITY GRID 240V, 1ø,3W 11101 - A 100A 15 (N) POLARIS BLOCK POLARIS SUPPLY SIDE TAP POINT OF INTERCONNECTION C:\USERS\EMILIANO.MORALES\DESKTOP\WORKING PROJECTS\1235_WILSHIRE_MINNIE\CD100\WILSHIRE MINNIE_WORKINGDOCS_V0\WILSHIRE MINNIE.DWG POI-8 ONE LINE CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 PROJECT DETAILS: PV SYSTEM: ·355.88 kW DC ·250.8 kW AC ·331.612 CEC AC ENERGY STORAGE: ·243.2 kW AC ·756.6 kWH E609 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM ORIGINAL CONTRACT NUMBER: 3003197607 PJT #: PROP-001235 ##KEYED NOTES#EQUIPMENT NOTES# A INTERCONNECTION LOCATION NTS COMMUNICATION CIRCUIT IDENTIFIER ##KEYED NOTES#EQUIPMENT NOTES# A INTERCONNECTION LOCATION NTS COMMUNICATION CIRCUIT IDENTIFIER SYSTEM SUMMARY 19.00 ACKW | 26.24 DCKW | 24.45 CECKW 19.00 BESS ACKW | 58.20 BESS KWH TOTAL FAULT CURRENTS UTILITY: 42,000A | GENERATORS: 156.2A + -18 14 1 13 14 ES-1 (3 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 1 1 . 1 . A - ( 1 3 ) 4 1 0 W M O D U L E W / ( 1 3 ) U 6 5 0 O P T S . ST R - 1 1 . 1 . B - ( 1 3 ) 4 1 0 W M O D U L E W / ( 1 3 ) U 6 5 0 O P T S . ST R - 1 1 . 1 . C - ( 1 2 ) 4 1 0 W M O D U L E W / ( 1 2 ) U 6 5 0 O P T S . ES-2 DC-11.1.1 SO L A R 3 16 BA T T E R Y 7 12 4A A-B 60A INV-11.1 + -18 14 1 13 14 ES-1 (3 ) S O L A R E D G E B A T - 1 0 K 1 P B A T T E R I E ( S ) ST R - 1 1 . 2 . A - ( 8 ) 4 1 0 W M O D U L E W / ( 8 ) U 6 5 0 O P T S . ST R - 1 1 . 2 . B - ( 8 ) 4 1 0 W M O D U L E W / ( 8 ) U 6 5 0 O P T S . ST R - 1 1 . 2 . C - ( 1 0 ) 4 1 0 W M O D U L E W / ( 1 0 ) U 6 5 0 O P T S . ES-2 DC-11.2.2 SO L A R 3 16 BA T T E R Y 7 12 4B A-B 40A INV-11.2 6 LC-11.1 6 8 5 (N) ACDS-2 SYSTEM AC DISCONNECT SWITCH,, SQUARE D, VHU363RB, 600V RATED, 240V OPERATIONAL, 100A, 3 POLE, NON-FUSIBLE, NEMA 3R. SEE REFERENCE SHEETS FOR KAIC RATING. AC-11.2 M9 4 (N) SCE PV PRODUCTION METER SOCKET ADDRESS: 1235 E WILSHIRE AVE BLDG 1429 SOMAH11, COOPER B-LINE, 114TB, 100 A, SERVICE 1 PHASE 3 WIRE 120/240 VAC, NEMA 3R AC-11.2 10 3 (N) ACDS-1 SYSTEM UTILITY AC DISCONNECT SWITCH, SQUARE D, VH223NRB, 240V RATED, 240V OPERATIONAL, 100A, 2 POLE, FUSIBLE, NEMA 3R, OR EQUIVALENT ON THE UTILITIES APPROVED LIST. CLASS R FUSE WITH REJECTION CLIPS OR CLASS J FOR 200KAIC RATING. A-B 100AAC-11.1 1. PV MODULES (64) QCELLS NORTH AMERICA Q.PEAK DUO BLK ML-G10.C+ 410 2. (64) SOLAREDGE DC OPTIMIZER U650 3. DC PV AND ESS CONNECTION UNIT W/ INTEGRAL LOAD BREAK DISCONNECT 4. 4A: (1) SOLAREDGE SE11400H-US HOME HUB [SI1-SB], 11,400W, 240VAC, 1ø, 3W 4B: (1) SOLAREDGE SE7600H-US HOME HUB [SI1-SB], 7,600W, 240VAC, 1ø, 3W 5. (N) REVENUE GRADE METER, 1ø, INTERGRATED RGM, W/ NOT REQUIRED CTS 6. (1) LOAD CENTER, 100A, 1ø, MIN.240VAC, MIN. 22KAIC, NEMA 3R 7. NOT USED 8. (N) ACDS-2 SYSTEM AC DISCONNECT SWITCH, SQUARE D, VHU363RB, 600V RATED, 240V OPERATIONAL, 100A, 3 POLE, NON-FUSIBLE, NEMA 3R. SEE REFERENCE SHEETS FOR KAIC RATING. 9. (N) SCE PV PRODUCTION METER SOCKET ADDRESS: 1235 E WILSHIRE AVE BLDG 1429 SOMAH11, COOPER B-LINE, 114TB, 100A, SERVICE: 1 PHASE 3 WIRE 120/240 VAC, # JAW, NEMA 3R, EUSERC: 304 10. (N) ACDS-1 SYSTEM UTILITY AC DISCONNECT SWITCH, SQUARE D, VH223NRB, 240V RATED, 240V OPERATIONAL, 100A, 2 POLE, FUSIBLE, NEMA 3R, OR EQUIVALENT ON THE UTILITIES APPROVED LIST. CLASS R FUSE WITH REJECTION CLIPS OR CLASS J FOR 200KAIC RATING. 11. (E) MAIN SERVICE EQUIPMENT: 1 PHASE 3 WIRE 120/240 VAC, 125A 12. MANUFACTURER INTERGRATED CELL CARD 13. (6) SOLAREDGE BAT-10K1P BATTERIES, 9.70KWH, 5,000DCW, NEMA 3R, MOUNTED TO WALL OR MANUFACTURER FLOOR MOUNT KIT 14. NOT USED 15. (N) POLARIS BLOCKS 16. NOT USED 1. (E) MAIN SWITCHGEAR AND (N) POINT OF AC INTERCONNECTION. ALL CONNECTIONS MADE INSIDE (E) SWITCHGEAR AT OTHER THAN CIRCUIT BREAKERS OR FUSED SWITCHES LISTED FOR USE WITH THAT SWITCHGEAR SHALL BE PERFORMED FOLLOWING MANUFACTURERS INSTRUCTIONS OR BE RE-LISTED BY A NRTL. ALL TERMINATIONS OF ALUMINUM CONDUCTORS SHALL BE WITH HIGH PRESS CRIMP LUGS ONLY. WARNING LABEL DETAIL 1/E800 2. (E) UTILITY TENANT LOAD METER. UTILITY REFERENCE METER NUMBER: 222013-124041 3. (N) PV SYSTEM UTILITY AC DISCONNECT 'ACDS-1'. WARNING LABEL DETAIL 1/E810 4. (N) UTILITY BIDIRECTIONAL KWH METER. WARNING LABEL DETAIL 1/E810 5. (N) PV SYSTEM MAINTENANCE AC DISCONNECT 'ACDS-2'. WARNING LABEL DETAIL 2/E800 & 1/E810 6. NOT USED 7. (N) GRID-INTERACTIVE PV INVERTER LISTED TO UL 1741 WITH GROUND FAULT DETECTION & INTERRUPTION. WARNING LABEL DETAIL 15/E800. 8. NOT USED 9. NOT USED 10. FOR SUPPLY SIDE CONNECTIONS, A PLAQUE SHALL BE INSTALLED AT THE MAIN SERVICE DISCONNECTING DEVICE AND THE PV SYSTEM UTILITY AC DISCONNECT INDICATING THE LOCATION OF THE RESPECTIVE SERVICE DISCONNECT. WARNING LABEL DETAIL 1/E800 & 1/E810 11. NOT USED 12. CONDUCTORS RUN IN PARALLEL SHALL BE INSTALLED PER ART 310.4/310.10(G) AND 250.122 (F). 13. NOT USED 14. NEW PULL/JUNCTION BOXES. PROVIDE SERVICE LOOP IN ALL DC BRANCH CONDUCTORS SOURCED FROM ROOFTOPS, MIN LOOP RADIUS = 12X CONDUCTOR DIAMETER. 15. NOT USED 16. (N) INVERTER INTERNAL DC DISCONNECT SWITCH(ES). WARNING LABEL DETAIL 3/E800 17. NOT USED 18. (N) PV MODULE LISTED TO UL 1703. 19. EXTRA MODULES THAT ARE UNABLE TO BE PAIRED WILL HAVE THEIR OWN OPTIMIZER. 20. (N) COMMUNICATION WIRING TO FOLLOW MANUFACTURING SPECIFICATIONS. 21. DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO THE ACCEPTED MEASURE. 22. BATTERY AC OUTPUT POWER IS LIMITED TO THE CORRESPONDING INVERTER OR TOTAL BATTERIES CONNECTED TO A SINGLE INVERTER,WHICHEVER IS LOWER. 23. BATTERIES SHOULD NOT BE INSTALLED IN DIRECT SUNLIGHT OR LOCATIONS SUBJECTED TO WATER SPRAY. SPRINKLERS SHOULD BE DIVERTED WHEN NECESSARY. 24. BATTERIES CAN COMMUNICATE WIRELESSLY OR VIA RS-485 TO INVERTER. BATTERIES WITHIN 150' (IDEALLY 50') OF RESPECTIVE INVERTER CAN USE WIRELESS COMMUNICATIONS VIA SEDG HOME NETWORK CARD. 25. COMBINED PV AND BESS OUTPUT POWER IS LIMITED TO THE INVERTER AC RATING. 26. NOT USED # CAT5E 600V RATED SHIELDED CABLE. INSTALLER SHALL FOLLOW MANUFACTURES RECOMMENDATION FOR WIRE SIZING BASED ON LENGTH. EQUIPMENT TYPE SYSTEM IDENTIFIER X INDICATES LETTERS # INDICATES NUMBERS XX-#.# 1235 E WILSHIRE AVE BLDG 1429 SOMAH11 POI-11 DC STRING SCHEDULE STR-A STR-B STR-C TAG DESTINATION CIRCUIT LENGTH ² VD% MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES CIRCUIT LENGTH ² VD% MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES CIRCUIT LENGTH ² VD% MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES DC-11.1.1 INV-11.1 115 0.63%410 13 U650 8 / 16¹115 0.60%410 13 U650 8 / 16¹110 0.56%410 12 U650 8 / 16¹ DC-11.2.2 INV-11.2 90 0.31%410 8 U650 8 / 16¹60 0.19%410 8 U650 8 / 16¹35 0.15%410 10 U650 8 / 16¹ ¹ MAXIMUM STRING LENGTH IS USING MANUFACTURES EXCEPTION ² LENGTHS ARE ESTIMATED FOR CALCULATIONS, CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS AND TAKEOFFS ³ WHERE EXPOSED TO PHYSICAL DAMAGE #6 TO BE USED PER NEC 250.120(C) ⁴ AFC VALUES ARE CALCULATED BASED ON WIRE LENGTHS. LENGTHS SHOULD REMAIN GREATER THAN OR EQUAL TO THE LENGTH LISTED IN THE TABLE. POI-11 DC WIRE SCHEDULE TAG WIRE GAUGE CONDUCTOR JACKET CCC PER CONDUIT GROUNDING ³EMT RMC PVC 40 PVC 80 DC-11.1.1 CU #8 THWN2 6 CU #10 1"1"1"1 1/4" DC-11.2.2 CU #8 THWN2 6 CU #10 1"1"1"1 1/4" POI-11 AC WIRE SCHEDULE LABEL DESTINATION NOMINAL VAC LINE SELECTION FLA FLAX1.25 PHASE CONDUCTOR NEUTRAL CONDUCTOR GROUNDING CONDUCTOR CONDUCTORS PER PHASE CONDUIT QTY CIRCUIT LENGTH ² SEGMENT VD% DC/AC RATIO AFC START AFC END ⁴EMT IMC PVC 40 PVC 80 INV-11.1 LC-11.1 240 A-B 47.5 59.4 CU #6 CU #10 CU #10 1 1 5 0.09% 136.7%6,118 5,536 3/4"3/4"3/4"3/4" INV-11.2 LC-11.1 240 A-B 31.7 39.6 CU #8 CU #10 CU #10 1 1 5 0.10% 140.3%6,118 5,257 1/2"1/2"3/4"3/4" LC-11.1 AC-11.2 240 A-B 79.2 99.0 CU #3 CU #8 CU #8 1 1 70 1.11%--24,234 6,118 1"1"1"1" AC-11.2 AC-11.1 240 A-B 79.2 99.0 CU #3 CU #8 CU #8 1 1 5 0.08%--30,734 24,234 1"1"1"1" AC-11.1 POI-11.11 240 A-B 79.2 99.0 CU #3 CU #3 CU #8 1 1 5 0.08%--42,000 30,734 1"1"1"1 1/4" M M M M M FACILITY LOADS (N) TENANT METERS (TYP.) UTILITY METER REFERENCE NUMBER: 222013-124041 SCE UTILITY GRID 240V, 1ø,3W 11101 - A 125A 15 (N) POLARIS BLOCK POLARIS SUPPLY SIDE TAP POINT OF INTERCONNECTION C:\USERS\EMILIANO.MORALES\DESKTOP\WORKING PROJECTS\1235_WILSHIRE_MINNIE\CD100\WILSHIRE MINNIE_WORKINGDOCS_V0\WILSHIRE MINNIE.DWG POI-8 ONE LINE CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 PROJECT DETAILS: PV SYSTEM: ·355.88 kW DC ·250.8 kW AC ·331.612 CEC AC ENERGY STORAGE: ·243.2 kW AC ·756.6 kWH E610 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM ORIGINAL CONTRACT NUMBER: 3003197607 PJT #: PROP-001235 NOTE: 1.RED BACKGROUND 2.WHITE LETTERING 3.TEXT HEIGHT: 1/8" MIN. 3 1/8" NOTE: 1. MARKING PER ART 690.54 2. RED BACKGROUND 3. WHITE LETTERING 4. TEXT HEIGHT: 1/8" MIN. NOTE: 1. RED BACKGROUND 2. WHITE LETTERING 3. TEXT HEIGHT: 1/8" MIN. 1 POINT OF INTERCONNECTION Scale NTS 7 INVERTER AC CIRCUIT BREAKER Scale NTS 8 SHOCK HAZARD Scale NTS 4 PV SYSTEM MAINTENANCE DISCONNECT Scale NTS 2 PV SYSTEM UTILITY AC DISCONNECT Scale NTS 5 MAIN SERVICE WITH REMOTE PV SYSTEM DISCONNECT Scale NTS 16 UTILITY NET GENERATION OUTPUT Scale NTS 9 INVERTER ID Scale NTS STRING INVERTERS CENTRAL INVERTERS 3 1/8" 6 AC COMBINER PANEL Scale NTS 3 5/8" 3 1/8" 3 DC DISCONNECT Scale NTS NOTE: 1. MARKING PER ART 690.17, 690.53 2. RED BACKGROUND 3. WHITE LETTERING 4. TEXT HEIGHT: 1/8" MIN. CAUTION SOLAR ELECTRIC SYSTEM CONNECTED CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECT LOCATED AS SHOWN ! DO NOT ADD LOADS PHOTOVOLTAIC SYSTEM COMBINER PANEL WARNING ! LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): CEC 2022: 705.12(B)(3)(2), NEC 2020: 705.12(B)(3)(2), NEC 2017: 705.12(B)(2)(3)(b), NEC 2014: 705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4) ELECTRICAL SHOCK HAZARD WARNING! LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2022: 690.13(B), NEC 2020: 690.13(B), NEC 2017: 690.13(B), NEC 2014: 690.17(E), NEC 2011: 690.17(4) TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: AMPS VAC PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2022: 690.54, NEC 2020: 690.54, NEC 2017: 690.54, NEC 2014: 690.54, NEC 2011: 690.54 INVERTER DC SYSTEM SIZE : NUMBER OF STRINGS: MODULES PER STRING: kW DC SYSTEM SIZE ____kW POINT OF INTERCONNECTION PHOTOVOLTAIC POWER SOURCE ELECTRICAL SHOCK HAZARD WARNING! TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION DC PHOTOVOLTAIC DISCONNECT PHOTOVOLTAIC DC DISCONNECT MAXIMUM POWER POINT VOLTAGE(Vmp): MAXIMUM POWER POINT CURRENT(Imp): MAXIMUM SYSTEM VOLTAGE(Voc): SHORT-CIRCUIT CURRENT(Isc): V A V A LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): CEC 2022: 690.53, NEC 2020: 690.53, NEC 2017: 690.53, NEC 2014: 690.53, NEC 2011: 690.53 15 INVERTER WARNING Scale NTS ELECTRICAL SHOCK HAZARD WARNING! LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2022: 690.13(B), NEC 2020: 690.13(B), NEC 2017: 690.13(B), NEC 2014: 690.17(E), NEC 2011: 690.17(4) TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NOT USED 13 NOT USED Scale NTS 12 RAPID SHUTDOWN LABEL Scale NTS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS 6" 3.5"TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): CEC 2022: 690.56(C)(1), NEC 2020: 690.56(C)(1); NEC 2017: 690.56(C)(1)(a) LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2022: 690.13(B), NEC 2020: 690.13(B), NEC 2017: 690.13(B), NEC 2014: 690.17(E), NEC 2011: 690.17(4) ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING!! WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): CEC 2022: 705.12(B)(3)(2), NEC 2020: 705.12(B)(3)(2), NEC 2017: 705.12(B)(2)(3)(b), NEC 2014: 705.12(D)(2)(3)(b), NEC 2011: 705.12(D)(7) NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: AMPS VAC PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2022: 690.54, NEC 2020: 690.54, NEC 2017: 690.54, NEC 2014: 690.54, NEC 2011: 690.54 ELECTRICAL SHOCK HAZARD WARNING! LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2022: 690.13(B), NEC 2020: 690.13(B), NEC 2017: 690.13(B), NEC 2014: 690.17(E), NEC 2011: 690.17(4) TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION INV-1 LABEL LOCATION: INVERTER (1) INV-2 LABEL LOCATION: INVERTER (2) [When applicable] INV-3 LABEL LOCATION: INVERTER (3) [When applicable] INV-4 LABEL LOCATION: INVERTER (4) [When applicable] LABEL LOCATION: INSTALLED WITHIN 3' OF RAPID SHUT DOWN SWITCH PER CODE(S): NEC 2020: 690.56(C)(2), CEC 2022: 690.56(C)(2), IFC 2018: 1204.5.3 RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 10 RAPID SHUTDOWN SWITCH Scale NTS WARNING! SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM DUAL POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): CEC 2022: 705.12(C), NEC 2020: 705.12(C) 14 NOT USED Scale NTS NOT USED 11 NOT USED Scale NTS NOT USED CLASS J FUSE ONLY WARNING! LABEL LOCATION: FUSED AC DISCONNECT(S) FAST-ACTING, CURRENT-LIMIT EQUIVALENT REQUIRED TO PREVENT DAMAGE CAUSED BY SHORT-CIRCUIT EVENTS. D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG WARNING LABELS CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH E800 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #ESTAMP WILSHIRE MINNIE 1209 E WILSHIRE AVE UNIT# MTR02 1209 3/4 E WILSHIRE AVE UNIT# ELE01 1221 E WILSHIRE AVE UNIT# MTR02 1221 3/4 E WILSHIRE AVE UNIT# ELE01 1229 E WILSHIRE AVE UNIT# MTR02 1229 3/4 E WILSHIRE AVE UNIT# ELE01 1233 E WILSHIRE AVE UNIT# MTR01 1401 S MINNIE ST UNIT# MTR01 1403 S MINNIE ST UNIT# MTR01 1425 S MINNIE ST UNIT# MTR01 APN: 014-251-49 / 014-251-50 DEVELOPER: C&C DEVELOPMENT 1 ESS AC DISCONNECT Scale NTS 3 POI-1 ESS ARC FLASH AND SHOCK HAZARD Scale NTS 4 POI-2 ESS ARC FLASH AND SHOCK HAZARD Scale NTS 1 0 0 N.A. 2 NFPA 704 SIGNAGE - SEDG ENERGY BANK BESS Scale NTS 15" 15" 6" 7-1/2"7-1/2" LABEL LOCATION: SIGNS SHOULD BE PLACED WHERE THEY ARE EASILY VISIBLE IN CASE OF AN EMERGENCY, SUCH AS ON EXTERIOR WALLS OF BUILDINGS, ENTRANCES TO ROOMS OR AREAS, AND PRINCIPAL ACCESS POINTS TO EXTERIOR STORAGE AREAS. LABEL LOCATION: ON OR NEAR THE ESS DISCONNECTING MEANS I.E INVERTERS FOR DC-COUPLED ESS ENERGY STORAGE SYSTEM AC DISCONNECT ENERGY STORAGE SYSTEM DISCONNECT ARC FLASH AND SHOCK HAZARD WARNING! APPROPRIATE PPE AND TOOLS REQUIRED WHILE WORKING ON THIS EQUIPMENT REFER TO NFPA 70 E. LABEL LOCATION: ESS AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020 706.15(C)(4) 2 7/8" 4 1/8" NOMINAL ESS AC VOLTAGE: MAXIMUM ESS DC VOLTAGE: AVAILABLE FAULT CURRENT DERIVED FROM THE ESS: DATE CALCULATION PREFORMED: 240 VAC 450 VDC 222A 2/18/26 ENERGY STORAGE SYSTEM DISCONNECT ARC FLASH AND SHOCK HAZARD WARNING! APPROPRIATE PPE AND TOOLS REQUIRED WHILE WORKING ON THIS EQUIPMENT REFER TO NFPA 70 E. LABEL LOCATION: ESS AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020 706.15(C)(4) 2 7/8" 4 1/8" NOMINAL ESS AC VOLTAGE: MAXIMUM ESS DC VOLTAGE: AVAILABLE FAULT CURRENT DERIVED FROM THE ESS: DATE CALCULATION PREFORMED: 240 VAC 450 VDC 296 A 2/18/26 5 POI-3 ESS ARC FLASH AND SHOCK HAZARD Scale NTS 6 POI-4 ESS ARC FLASH AND SHOCK HAZARD Scale NTS ENERGY STORAGE SYSTEM DISCONNECT ARC FLASH AND SHOCK HAZARD WARNING! APPROPRIATE PPE AND TOOLS REQUIRED WHILE WORKING ON THIS EQUIPMENT REFER TO NFPA 70 E. LABEL LOCATION: ESS AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020 706.15(C)(4) 2 7/8" 4 1/8" NOMINAL ESS AC VOLTAGE: MAXIMUM ESS DC VOLTAGE: AVAILABLE FAULT CURRENT DERIVED FROM THE ESS: DATE CALCULATION PREFORMED: 240 VAC 450 VDC 222 A 2/18/26 7 POI-5 ESS ARC FLASH AND SHOCK HAZARD Scale NTS 8 POI-6 ESS ARC FLASH AND SHOCK HAZARD Scale NTS ENERGY STORAGE SYSTEM DISCONNECT ARC FLASH AND SHOCK HAZARD WARNING! APPROPRIATE PPE AND TOOLS REQUIRED WHILE WORKING ON THIS EQUIPMENT REFER TO NFPA 70 E. LABEL LOCATION: ESS AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020 706.15(C)(4) 2 7/8" 4 1/8" NOMINAL ESS AC VOLTAGE: MAXIMUM ESS DC VOLTAGE: AVAILABLE FAULT CURRENT DERIVED FROM THE ESS: DATE CALCULATION PREFORMED: 240 VAC 450 VDC 222 A 2/18/26 9 POI-7 ESS ARC FLASH AND SHOCK HAZARD Scale NTS ENERGY STORAGE SYSTEM DISCONNECT ARC FLASH AND SHOCK HAZARD WARNING! APPROPRIATE PPE AND TOOLS REQUIRED WHILE WORKING ON THIS EQUIPMENT REFER TO NFPA 70 E. LABEL LOCATION: ESS AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020 706.15(C)(4) 2 7/8" 4 1/8" NOMINAL ESS AC VOLTAGE: MAXIMUM ESS DC VOLTAGE: AVAILABLE FAULT CURRENT DERIVED FROM THE ESS: DATE CALCULATION PREFORMED: 240 VAC 450 VDC 148 A 2/18/26 ENERGY STORAGE SYSTEM DISCONNECT ARC FLASH AND SHOCK HAZARD WARNING! APPROPRIATE PPE AND TOOLS REQUIRED WHILE WORKING ON THIS EQUIPMENT REFER TO NFPA 70 E. LABEL LOCATION: ESS AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020 706.15(C)(4) 2 7/8" 4 1/8" NOMINAL ESS AC VOLTAGE: MAXIMUM ESS DC VOLTAGE: AVAILABLE FAULT CURRENT DERIVED FROM THE ESS: DATE CALCULATION PREFORMED: 240 VAC 450 VDC 148 A 2/18/26 ENERGY STORAGE SYSTEM DISCONNECT ARC FLASH AND SHOCK HAZARD WARNING! APPROPRIATE PPE AND TOOLS REQUIRED WHILE WORKING ON THIS EQUIPMENT REFER TO NFPA 70 E. LABEL LOCATION: ESS AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020 706.15(C)(4) 2 7/8" 4 1/8" NOMINAL ESS AC VOLTAGE: MAXIMUM ESS DC VOLTAGE: AVAILABLE FAULT CURRENT DERIVED FROM THE ESS: DATE CALCULATION PREFORMED: 240 VAC 450 VDC 148 A 2/18/26 BATTERY ID CONNECTED INV LABEL : INV SERIAL NO.: BATTERY SERIAL NO.: LABEL LOCATION: All Batteries[When applicable]. Use Connected Inv Label names as 1.1, 1.2,..for POI#1, 2.1, 2.2,...for POI#2 and so on. Last 4 digits of the serial numbers can be used. INV- LABEL LOCATION: ALL INVERTERS Match Inv labels as shown in Plans. Ex. 1.1, 1.2, 1.3, 2.1,2.2, 3.1, 3.2 and so on 10 BATTERY MAPPING SIGNAGES Scale NTS D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG WARNING LABELS CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH E801 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & #ESTAMP WILSHIRE MINNIE 1209 E WILSHIRE AVE UNIT# MTR02 1209 3/4 E WILSHIRE AVE UNIT# ELE01 1221 E WILSHIRE AVE UNIT# MTR02 1221 3/4 E WILSHIRE AVE UNIT# ELE01 1229 E WILSHIRE AVE UNIT# MTR02 1229 3/4 E WILSHIRE AVE UNIT# ELE01 1233 E WILSHIRE AVE UNIT# MTR01 1401 S MINNIE ST UNIT# MTR01 1403 S MINNIE ST UNIT# MTR01 1425 S MINNIE ST UNIT# MTR01 APN: 014-251-49 / 014-251-50 DEVELOPER: C&C DEVELOPMENT NGOM M SCE LINE SIDE DISCONNECT GENERATION LOAD SIDE DISCONNECTUTILITY DISTRIBUTION SYSTEM 1 3 8 2 7 9 PV GENERATION FACILITY 46 5 SCE LINE SIDE DISCONNECT LABEL LOCATION: LINE SIDE DISCONNECT LABEL LOCATION: LOAD SIDE DISCONNECT LABEL LOCATION: IF PANEL MODIFICATIONS ARE MADE APPROPRIATE PLACARDS MUST BE INSTALLED LABELING THE SECTIONS. 1 2 7 LABEL LOCATION: THE WIRING SEQUENCE OF FACTORY-INSTALLED TEST-BYPASS BLOCKS, FROM LEFT TO RIGHT, IS LINE-LOAD, LINE-LOAD, LINE-LOAD. THIS WIRING SEQUENCE SHALL BE PERMANENTLY LABELED IN 3/4-INCH BLOCK LETTERS BELOW THE TEST-BYPASS TERMINALS. LINE AND LOAD CONDUCTORS SHALL BE CONNECTED ONLY TO TEST-BYPASS BLOCK TERMINALS DESIGNED AS LINE AND LOAD, RESPECTIVELY. 3 LABEL LOCATION: ON THE METER PANEL OR ADJACENT TO THE METER SOCKET. ACCEPTABLE METHODS FOR LABELING CUSTOMER NGO METERING SECTIONS OR PANEL(S) SHALL BE EITHER BY PERMANENTLY ATTACHED MACHINE-ENGRAVED LAMINATED PHENOLIC (OR EQUAL) TAGS OR BY PERMANENT STENCILED PAINT LETTERING. TEXT HEIGHT MIN. 1/4". 8 SCE METERING PLACARDS NTS SOLAR INTERCONNECTION TERMINATION SECTION LINE LOAD SCE UTILITY TERMINATION SECTION DISCONNECT 1 OF 2 GENERATION LOAD SIDE DISCONNECT DISCONNECT 2 OF 2 NET GENERATION OUTPUT METERING NOTE: SCE REQUIRES A SAFETY-SOCKET BOX WITH FACTORY-INSTALLED TEST-BYPASS BLOCKS FOR NON-INSTRUMENT RATED (SELF-CONTAINED) NGO METERING. FOR SWITCHBOARDS/SWITCHGEAR, THE CUSTOMER MUST LABEL THE GENERATOR OUTPUT BUS/CABLE DIRECTION (E.G., "TOP GENERATOR FED"). IF NGO AND PCC METERING ARE SEPARATED BY OVER 100 FEET OR ON DIFFERENT LEVELS, A PERMANENT SIGN AT THE PCC METER MUST INDICATE THE NGO METER'S LOCATION. CURRENT FLOW LABEL LOCATION: FOR INSTRUMENT TRANSFORMER RATED CT NGOM PANELS, THE ARROW POINTING TOWARDS THE UTILITY SIDE DISCONNECT SHALL BE INSTALLED ON THE INSIDE SIDE WALL OF PANEL OR ON THE OUTSIDE FRONT OF NGOM PANEL. 5 SCE LINE SIDE PV LOAD SIDE LABEL LOCATION: PULL SECTIONS 4 GRID GENERATION LABEL LOCATION: GRID AND GENERATION CONDUCTORS 6 LABEL LOCATION: PLACE A UNIQUE ADDRESS PLACARD ON THE NGOM THAT MATCHES THE AHJ PERMIT AND THE SCE SERVICE REQUEST ADDRESS. 9 123 MAIN ST. SOMAH1 NOTE: IF INTERCONNECTION IS MADE WITHIN A NEW TERMINATION CAN, THE "SOLAR INTERCONNECTION TERMINATION SECTION" PLACARD IS REQUIRED D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG SITE PLACARDS CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH E810 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG #ESTAMP MULTIPLE SOURCES OF POWER CAUTION: 1209 E WILSHIRE AVE UNIT# MTR02 PV ARRAY DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION [NEC 690.56(B)] WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, A DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE INSTALLED AT EACH DC PV SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF ALL AC AND DC PV SYSTEM DISCONNECTING MEANS IN THE BUILDING. [NEC 690.4(D)] CAUTION: DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION [NEC 690.56(B)] WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, A DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE INSTALLED AT EACH DC PV SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF ALL AC AND DC PV SYSTEM DISCONNECTING MEANS IN THE BUILDING. [NEC 690.4(D)] CAUTION: DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION [NEC 690.56(B)] WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, A DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE INSTALLED AT EACH DC PV SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF ALL AC AND DC PV SYSTEM DISCONNECTING MEANS IN THE BUILDING. [NEC 690.4(D)] CAUTION: DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION [NEC 690.56(B)] WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, A DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE INSTALLED AT EACH DC PV SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF ALL AC AND DC PV SYSTEM DISCONNECTING MEANS IN THE BUILDING. [NEC 690.4(D)] CAUTION: DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION [NEC 690.56(B)] WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, A DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE INSTALLED AT EACH DC PV SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF ALL AC AND DC PV SYSTEM DISCONNECTING MEANS IN THE BUILDING. [NEC 690.4(D)] CAUTION: DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION [NEC 690.56(B)] WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, A DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE INSTALLED AT EACH DC PV SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF ALL AC AND DC PV SYSTEM DISCONNECTING MEANS IN THE BUILDING. [NEC 690.4(D)] PV ARRAY PV ARRAY * YOU ARE HERE * MAIN SERVICE DISCONNECT POI LOCATION (EXT.) AC DISCONNECT(FUSED)(EXT.) NGOM METER (EXT.) AC DISCONNECT(NON-FUSED)(EXT.) BESS LOCATION (EXT.) 1213 E WILSHIRE AVE 1401 MINNIE ST PV INVERTERS LOCATION (EXT.) POI-4POI-3POI-2POI-1 POI-6POI-5 1221 E WILSHIRE AVE UNIT# MTR02 1229 E WILSHIRE AVE UNIT# MTR02 1233 E WILSHIRE AVE UNIT# MTR01 1401 S MINNIE ST UNIT# MTR01 1403 S MINNIE ST UNIT# MTR01 CAUTION: DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION [NEC 690.56(B)] WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, A DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE INSTALLED AT EACH DC PV SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF ALL AC AND DC PV SYSTEM DISCONNECTING MEANS IN THE BUILDING. [NEC 690.4(D)] POI-7 1425 S MINNIE ST UNIT# MTR01 MULTIPLE SOURCES OF POWER MULTIPLE SOURCES OF POWER MULTIPLE SOURCES OF POWER MULTIPLE SOURCES OF POWER MULTIPLE SOURCES OF POWER MULTIPLE SOURCES OF POWER E WILSHIRE AVE 1209 E WILSHIRE AVE 1201 E WILSHIRE AVE PV ARRAY PV ARRAY E WILSHIRE AVE 1225 E WILSHIRE AVE 1221 E WILSHIRE AVE PV ARRAY PV ARRAY BESS LOCATION (EXT.) PV INVERTERS LOCATION (EXT.) * YOU ARE HERE * MAIN SERVICE DISCONNECT POI LOCATION (EXT.)AC DISCONNECT(FUSED)(EXT.) NGOM METER (EXT.) AC DISCONNECT(NON-FUSED)(EXT.) E WILSHIRE AVE BESS LOCATION (EXT.) PV INVERTERS LOCATION (EXT.) 1229 E WILSHIRE AVE PV ARRAY 1235 E WILSHIRE AVE * YOU ARE HERE * MAIN SERVICE DISCONNECT POI LOCATION (EXT.) AC DISCONNECT(NON-FUSED)(EXT.)NGOM METER (EXT.) AC DISCONNECT(FUSED)(EXT.) E WILSHIRE AVE 1233 E WILSHIRE AVE BESS LOCATION (EXT.) PV INVERTERS LOCATION (EXT.) * YOU ARE HERE * MAIN SERVICE DISCONNECT POI LOCATION (EXT.) AC DISCONNECT(NON-FUSED)(EXT.) NGOM METER (EXT.) AC DISCONNECT(FUSED)(EXT.) MINNIE ST BESS LOCATION (EXT.) * YOU ARE HERE * MAIN SERVICE DISCONNECT POI LOCATION (EXT.) PV INVERTERS LOCATION (EXT.) AC DISCONNECT(FUSED)(EXT.) NGOM METER (EXT.) AC DISCONNECT(NON-FUSED)(EXT.) MINNIE ST MINNIE ST PV ARRAY 1403 MINNIE ST BESS LOCATION (EXT.) PV INVERTERS LOCATION (EXT.) * YOU ARE HERE * MAIN SERVICE DISCONNECT POI LOCATION (EXT.)AC DISCONNECT(FUSED)(EXT.) NGOM METER (EXT.) AC DISCONNECT(NON-FUSED)(EXT.) PV ARRAY 1425 MINNIE ST BESS LOCATION (EXT.) PV INVERTERS LOCATION (EXT.) * YOU ARE HERE * MAIN SERVICE DISCONNECT POI LOCATION (EXT.)AC DISCONNECT(FUSED)(EXT.) NGOM METER (EXT.) AC DISCONNECT(NON-FUSED)(EXT.) WILSHIRE MINNIE 1209 E WILSHIRE AVE UNIT# MTR02 1209 3/4 E WILSHIRE AVE UNIT# ELE01 1221 E WILSHIRE AVE UNIT# MTR02 1221 3/4 E WILSHIRE AVE UNIT# ELE01 1229 E WILSHIRE AVE UNIT# MTR02 1229 3/4 E WILSHIRE AVE UNIT# ELE01 1233 E WILSHIRE AVE UNIT# MTR01 1401 S MINNIE ST UNIT# MTR01 1403 S MINNIE ST UNIT# MTR01 1425 S MINNIE ST UNIT# MTR01 APN: 014-251-49 / 014-251-50 DEVELOPER: C&C DEVELOPMENT 1235 E WILSHIRE AVE BLDG 1421 SOMAH9 DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION [NEC 690.56(B)] WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, A DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE INSTALLED AT EACH DC PV SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF ALL AC AND DC PV SYSTEM DISCONNECTING MEANS IN THE BUILDING. [NEC 690.4(D)] POI-9 POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN CAUTION: 1235 E WILSHIRE AVE BLDG 1425 SOMAH10 DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION [NEC 690.56(B)] WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, A DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE INSTALLED AT EACH DC PV SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF ALL AC AND DC PV SYSTEM DISCONNECTING MEANS IN THE BUILDING. [NEC 690.4(D)] POI-10 POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN CAUTION: 1235 E WILSHIRE AVE BLDG 1429 SOMAH11 DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION [NEC 690.56(B)] WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, A DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE INSTALLED AT EACH DC PV SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF ALL AC AND DC PV SYSTEM DISCONNECTING MEANS IN THE BUILDING. [NEC 690.4(D)] POI-11 PV ARRAY PV ARRAY POI LOCATION (EXT.) POI LOCATION (EXT.) TENANT METERS (EXT.) AC DISCONNECT(FUSED)(EXT.) NGOM METER (EXT.) AC DISCONNECT(NON-FUSED)(EXT.) BESS LOCATION (EXT.) TENANT METERS (EXT.)AC DISCONNECT(FUSED)(EXT.) NGOM METER (EXT.) AC DISCONNECT(NON-FUSED)(EXT.) BESS LOCATION (EXT.) BLDG 1421 BLDG 1429 PV INVERTER AND ESS AC DISCONNECT LOCATION (EXT.) PV INVERTER AND ESS AC DISCONNECT LOCATION (EXT.) C:\USERS\EMILIANO.MORALES\DESKTOP\WORKING PROJECTS\1235_WILSHIRE_MINNIE\CD100\WILSHIRE MINNIE_WORKINGDOCS_V0\WILSHIRE MINNIE.DWG SITE PLACARDS CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 PROJECT DETAILS: PV SYSTEM: ·355.88 kW DC ·250.8 kW AC ·331.612 CEC AC ENERGY STORAGE: ·243.2 kW AC ·756.6 kWH E811 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM ORIGINAL CONTRACT NUMBER: 3003197607 PJT #: PROP-001235 C:\USERS\EMILIANO.MORALES\DESKTOP\WORKING PROJECTS\1235_WILSHIRE_MINNIE\CD100\WILSHIRE MINNIE_WORKINGDOCS_V0\WILSHIRE MINNIE.DWG POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN CAUTION: PV ARRAY POI LOCATION (EXT.) TENANT METERS (EXT.) AC DISCONNECT(FUSED)(EXT.) NGOM METER (EXT.) AC DISCONNECT(NON-FUSED)(EXT.) BESS LOCATION (EXT.) BLDG 1425 PV INVERTER AND ESS AC DISCONNECT LOCATION (EXT.) D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG REFERENCE SHEET - 1 CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH R100 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & WILSHIRE MINNIE 1209 E WILSHIRE AVE UNIT# MTR02 1209 3/4 E WILSHIRE AVE UNIT# ELE01 1221 E WILSHIRE AVE UNIT# MTR02 1221 3/4 E WILSHIRE AVE UNIT# ELE01 1229 E WILSHIRE AVE UNIT# MTR02 1229 3/4 E WILSHIRE AVE UNIT# ELE01 1233 E WILSHIRE AVE UNIT# MTR01 1401 S MINNIE ST UNIT# MTR01 1403 S MINNIE ST UNIT# MTR01 1425 S MINNIE ST UNIT# MTR01 APN: 014-251-49 / 014-251-50 DEVELOPER: C&C DEVELOPMENT D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG REFERENCE SHEET - 2 CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH R101 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & WILSHIRE MINNIE 1209 E WILSHIRE AVE UNIT# MTR02 1209 3/4 E WILSHIRE AVE UNIT# ELE01 1221 E WILSHIRE AVE UNIT# MTR02 1221 3/4 E WILSHIRE AVE UNIT# ELE01 1229 E WILSHIRE AVE UNIT# MTR02 1229 3/4 E WILSHIRE AVE UNIT# ELE01 1233 E WILSHIRE AVE UNIT# MTR01 1401 S MINNIE ST UNIT# MTR01 1403 S MINNIE ST UNIT# MTR01 1425 S MINNIE ST UNIT# MTR01 APN: 014-251-49 / 014-251-50 DEVELOPER: C&C DEVELOPMENT D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG REFERENCE SHEET - 3 CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH R102 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & WILSHIRE MINNIE 1209 E WILSHIRE AVE UNIT# MTR02 1209 3/4 E WILSHIRE AVE UNIT# ELE01 1221 E WILSHIRE AVE UNIT# MTR02 1221 3/4 E WILSHIRE AVE UNIT# ELE01 1229 E WILSHIRE AVE UNIT# MTR02 1229 3/4 E WILSHIRE AVE UNIT# ELE01 1233 E WILSHIRE AVE UNIT# MTR01 1401 S MINNIE ST UNIT# MTR01 1403 S MINNIE ST UNIT# MTR01 1425 S MINNIE ST UNIT# MTR01 APN: 014-251-49 / 014-251-50 DEVELOPER: C&C DEVELOPMENT D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG REFERENCE SHEET - 4 CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH R103 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & WILSHIRE MINNIE 1209 E WILSHIRE AVE UNIT# MTR02 1209 3/4 E WILSHIRE AVE UNIT# ELE01 1221 E WILSHIRE AVE UNIT# MTR02 1221 3/4 E WILSHIRE AVE UNIT# ELE01 1229 E WILSHIRE AVE UNIT# MTR02 1229 3/4 E WILSHIRE AVE UNIT# ELE01 1233 E WILSHIRE AVE UNIT# MTR01 1401 S MINNIE ST UNIT# MTR01 1403 S MINNIE ST UNIT# MTR01 1425 S MINNIE ST UNIT# MTR01 APN: 014-251-49 / 014-251-50 DEVELOPER: C&C DEVELOPMENT D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG REFERENCE SHEET - 5 CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH R104 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & WILSHIRE MINNIE 1209 E WILSHIRE AVE UNIT# MTR02 1209 3/4 E WILSHIRE AVE UNIT# ELE01 1221 E WILSHIRE AVE UNIT# MTR02 1221 3/4 E WILSHIRE AVE UNIT# ELE01 1229 E WILSHIRE AVE UNIT# MTR02 1229 3/4 E WILSHIRE AVE UNIT# ELE01 1233 E WILSHIRE AVE UNIT# MTR01 1401 S MINNIE ST UNIT# MTR01 1403 S MINNIE ST UNIT# MTR01 1425 S MINNIE ST UNIT# MTR01 APN: 014-251-49 / 014-251-50 DEVELOPER: C&C DEVELOPMENT D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG UL9540A CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH R105 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & WILSHIRE MINNIE 1209 E WILSHIRE AVE UNIT# MTR02 1209 3/4 E WILSHIRE AVE UNIT# ELE01 1221 E WILSHIRE AVE UNIT# MTR02 1221 3/4 E WILSHIRE AVE UNIT# ELE01 1229 E WILSHIRE AVE UNIT# MTR02 1229 3/4 E WILSHIRE AVE UNIT# ELE01 1233 E WILSHIRE AVE UNIT# MTR01 1401 S MINNIE ST UNIT# MTR01 1403 S MINNIE ST UNIT# MTR01 1425 S MINNIE ST UNIT# MTR01 APN: 014-251-49 / 014-251-50 DEVELOPER: C&C DEVELOPMENT D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG UL9540A CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH R106 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & WILSHIRE MINNIE 1209 E WILSHIRE AVE UNIT# MTR02 1209 3/4 E WILSHIRE AVE UNIT# ELE01 1221 E WILSHIRE AVE UNIT# MTR02 1221 3/4 E WILSHIRE AVE UNIT# ELE01 1229 E WILSHIRE AVE UNIT# MTR02 1229 3/4 E WILSHIRE AVE UNIT# ELE01 1233 E WILSHIRE AVE UNIT# MTR01 1401 S MINNIE ST UNIT# MTR01 1403 S MINNIE ST UNIT# MTR01 1425 S MINNIE ST UNIT# MTR01 APN: 014-251-49 / 014-251-50 DEVELOPER: C&C DEVELOPMENT D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG UL9540A CONTRACTOR: ENGINEERING APPROVAL: 600 CALIFORNIA ST #1800, SAN FRANCISCO, CA 94104 CA CL #750184 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. WILSHIRE MINNIE 1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA APN:014-251-49/014-251-50 DEVELOPER: C&C DEVELOPMENT DESCRIPTION DATE REV 0ORIGINAL06/23/25 BAHJ COMMENTS #2 12/10/25 CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 PROJECT DETAILS: PV SYSTEM: ·259.12 kW DC ·186.2 kW AC ·241.45 CEC AC ENERGY STORAGE: ·184.8 kW AC ·523.8 kWH R107 SHEET SIZE: REVISION: SHEET TITLE: 36" X 24" (ARCH D) DESIGNER: FINS_TM C PROJECT NUMBER: PROP-001235 ASYSTEM DOWNSIZED 09/05/25 AHJ COMMENTS #1 & WILSHIRE MINNIE 1209 E WILSHIRE AVE UNIT# MTR02 1209 3/4 E WILSHIRE AVE UNIT# ELE01 1221 E WILSHIRE AVE UNIT# MTR02 1221 3/4 E WILSHIRE AVE UNIT# ELE01 1229 E WILSHIRE AVE UNIT# MTR02 1229 3/4 E WILSHIRE AVE UNIT# ELE01 1233 E WILSHIRE AVE UNIT# MTR01 1401 S MINNIE ST UNIT# MTR01 1403 S MINNIE ST UNIT# MTR01 1425 S MINNIE ST UNIT# MTR01 APN: 014-251-49 / 014-251-50 DEVELOPER: C&C DEVELOPMENT YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs STRUCTURAL CALCULATIONS FOR THE WILSHIRE MINNIE ROOFTOP PV 1235 E WILSHIRE AVE. SANTA ANA, CA 92707 ORANGE COUNTY CA Issue Date: 10/24/2025 jeremy@roguestructures.com Rogue Structures Project #: 21-001 1 of 11 FOR PAGES 1-11 10/24/2510/24/25 WILSHIRE MINNIE ROOFTOP PV Project No. 21-001 6/26/25 PROJECT DESCRIPTION: - Existing buildings are being checked to a support PV system PROJECT LOCATION: 2 of 11 ASCE Hazards Report Address: 1235 E Wilshire Ave Santa Ana, California 92707 Standard:ASCE/SEI 7-16 Latitude:33.73068 Risk Category:II Longitude:-117.855471 Soil Class:D - Default (see Section 11.4.3) Elevation:89.14482221615128 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Wed Jun 25 2025 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Page 1 of 3https://ascehazardtool.org/Thu Jun 26 2025 3 of 11 WILSHIRE MINNIE ROOFTOP PV Project No. 21-001 6/26/25 ROOFTOP SOLAR PANELS PARALLEL TO THE ROOF SURFACE PER ASCE 7-16 29.4.4 Roof Mounted PV Attachment Calculations p = q h (GC p )(†E )(†a ) Kz =0.62 ASCE7 Table 26.10-1 Kzt =1.00 Kd =0.85 ASCE7 Table 26.6-1 V =95 mph Exposure =B qz =12.3 psf (Ultimate) Building Type: Surface Type: Roof Roof Angle : 10 Roof Height: 20 ft Height of Canopy †E=1.5 †a=0.8 1, 2e 2r, 2n GC:-2.0 -2.54 -28.7 -37.3 psf (Ultimate) -17.2 -22.4 psf (Working Stress) Module Dimensions Length Width Area inches inches sq. ft 74 41 21.07 Interior Zone 72 in Edge Zone 72 in Attachment area = 18.5 18.5 ft2 Load per attachment = 319 414 lbs See following page for manufacturer's allowable attachment uplift load Therefore the manufacturer's spacings are ok for the loads Enclosed Uplift Wind Pressure Manufacturer Spacing Information ݍ௛ = .00256 כ ܭ௭ כ ܭ௭௧ כ ܭௗ כ ܸ ଶ 4 of 11 WILSHIRE MINNIE ROOFTOP PV Project No. 21-001 6/26/25 5 of 11 WILSHIRE MINNIE ROOFTOP PV Project No. 21-001 6/26/25 ROOFTOP SOLAR PANELS PARALLEL TO THE ROOF SURFACE PER ASCE 7-16 29.4.4 Roof Mounted PV Attachment Calculations p = q h (GC p )(†E )(†a ) Kz =0.62 ASCE7 Table 26.10-1 Kzt =1.00 Kd =0.85 ASCE7 Table 26.6-1 V =95 mph Exposure =B qz =12.3 psf (Ultimate) Building Type: Surface Type: Roof Roof Angle : 2 Roof Height: 20 ft Height of Canopy †E=1.5 †a=0.8 1, 2e 2r, 2n GC:-1.6 -2.13 -23 -31.3 psf (Ultimate) -13.8 -18.8 psf (Working Stress) Module Dimensions Length Width Area inches inches sq. ft 74 41 21.07 Interior Zone 72 in Edge Zone 72 in Attachment area = 18.5 18.5 ft2 Load per attachment = 256 347 lbs See following page for manufacturer's allowable attachment uplift load Therefore the manufacturer's spacings are ok for the loads Enclosed Uplift Wind Pressure Manufacturer Spacing Information ݍ௛ = .00256 כ ܭ௭ כ ܭ௭௧ כ ܭௗ כ ܸ ଶ 6 of 11 WILSHIRE MINNIE ROOFTOP PV Project No. 21-001 6/26/25 7 of 11 WILSHIRE MINNIE ROOFTOP PV Project No. 21-001 6/26/25 Check Building for PV Roof Loads weight (psf) Wall Loads weight (psf) Roofing 4.4 Stucco 10 15/32" Sheathing 1.5 15/32" sheathing 1.5 Roof Trusses 3 2x6 @ 16"oc 1.5 Insulation 1.0 Gypboard 1.8 Fire Sprinklers 1.0 Misc 1.2 Girders 1.5 Wall Total Weight 16 psf Ceiling 1.8 Mechanical 1.5 Misc.1.3 Total 17.0 psf PV Weight 3.0 psf System Total 20.0 Check existing structure per California Existing Building Code Section 503.3 and 503.4 Vertical Capacity (CEBC 503.3) Lateral Capacity (CEBC 503.4) Building Areas (Worst Case) Building #1225 Roof Area 3024 ft2 Wall Area 500 ft2 PV Area 1609 ft2 Wind Check The modules are mounted parallel to the roof, therefore the wind loading will not change. Seismic Check Existing 59408 lbs Solar Weight 4826 lbs New Total Weight 64234 lbs Percentage Change 8.1% Total increase in weight to the structure is less than 10%, therefore the existing structure is ok Modules may not be walked on after installation. The live load on the roof is replaced with the dead load of the PV system. This is less than the live load, therefore the vertical system is ok to support the system. Photos of the existing roof were reviewed to look for signs of potential distress in the roof or poor drainage which increasing the load on the roof would make worse. The photos showed that the roof appeared to be in good condition without signs of damage or significant ponding. Based on this observation as well as the live load offset, the roof is sufficient to support the proposed PV system. 8 of 11 SS : 1.279 S1 : 0.457 F a : 1.2 F v : N/A SMS : 1.535 SM1 : N/A SDS : 1.023 SD1 : N/A T L : 8 PGA : 0.539 PGA M : 0.647 F PGA : 1.2 Ie : 1 C v : 1.356 Seismic Site Soil Class: Results: Data Accessed: Date Source: D - Default (see Section 11.4.3) USGS Seismic Design Maps Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Wed Jun 25 2025 Page 2 of 3https://ascehazardtool.org/Thu Jun 26 2025 9 of 11 The ASCE Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE Hazard Tool. Page 3 of 3https://ascehazardtool.org/Thu Jun 26 2025 10 of 11 WILSHIRE MINNIE ROOFTOP PV Project No. 21-001 6/26/25 Site Class=D-Default Seismic Design Category=D (ASCE Table 11.6-1) Importance Factor (IE) =1.00 (ASCE Table 1.5-2) Mapped Spectral Response acceleration @ short period (SS)=1.279 from OSHPD website Site Coefficient (Fa)=1.2 from OSHPD website Maximum Considered Spectral Response acceleration, short period (SMS)=1.535 (ASCE 11.4-1) Design Spectral Response acceleration @ short period (SDS)=1.023 (ASCE 11.4-3) Mapped Spectral acceleration @ 1-second period (S1)=0.457 from OSHPD website Site Coefficient (Fv)=1.84 (ASCE Table 11.4-2) Maximum Considered Spectral acceleration @ 1-second period (SM1)=0.842 (ASCE 11.4-2) Spectral acceleration @ 1-second period (SD1)=0.562 (ASCE 11.4-4) Long Period Transition Period (TL)=8 (ASCE Fig. 22-14) Short Period Transition Period (Ts)=0.55 (ASCE 11.4.6) Risk Category (Ie)=II (ASCE Table 1.5-2) Seismic Response Modification Factor (R)=6.50 (ASCE Table 12.2-1) Equivalent Lateral Force Procedure:[ASCE Section 12.8.1 ] Cs, max= 0.768 Cs, min=0.045 шϬ͘Ϭϭ Cs =0.157 10.0 0.020 0.75 0.112 V= 0.157 W (ULTIMATE) V= 0.110 W (ASD) SEISMIC DESIGN, ASCE 7-16 Story Height (hn) = Building Period Coefficient (Ct) = Exponent (x) = Fundamental Period (Ta) =(ASCE 12.8.2.1) 11 of 11