HomeMy WebLinkAbout1201-1235 E Wilshire Ave & 1401-1403, 1425 S Minnie St - PlanD:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
LEGEND AND ABBREVIATIONS
DISCLAIMER: PLEASE NOTE THAT THE ABBREVIATIONS, ANNOTATIONS, AND SYMBOLS LISTED ARE
INTENDED TO ILLUSTRATE THOSE THAT ARE COMMONLY USED; NOT ALL ARE NECESSARILY
UTILIZED WITHIN THIS SET OF DRAWINGS.
ATTIC VENT
FLUSH ATTIC VENT
PVC PIPE VENT
SATELLITE DISH
T-VENT
CHIMNEY
FIRE SETBACKS
METAL PIPE VENT
HARDSCAPE
PROPERTY LINEPL
MAIN PANEL & SUB
PANELS
INVERTER(S) WITH
INTEGRATED DC
DISCONNECT AND AFCI
GENERAL LOCATION OF
EQUIPMENT
METER SOCKET &
DISCONNECTS
PV LOAD CENTER
BESS
(IF APPLICABLE)
GENERAL NOTES
VICINITY MAP
AMPERE
ALTERNATING CURRENT
AC DISCONNECT
AMERICANS WITH DISABILITIES ACT
AVAILABLE FAULT CURRENT
AMERICAN SOCIETY FOR TESTING AND MATERIALS
BATTERY ENERGY STORAGE SYSTEM
BUILDING
CLEAR
CANOPY, NEW
CONCRETE
CONDITIONS OF USE
CANOPY, RETROFIT
DIRECT CURRENT
DIAMETER
DISTANCE
EQUAL
EQUIPMENT GROUNDING CONDUCTOR
EXISTING
EACH
ELECTRICAL METALLIC TUBING
GALVANIZED
GROUNDING ELECTRODE CONDUCTOR
GROUND
HOT DIPPED GALVANIZED
CURRENT
CURRENT AT MAX POWER
INVERTERS
SHORT CIRCUIT CURRENT
KILOVOLT AMPERE
KILOWATT
KILOWATT-HOUR
LOAD BEARING WALL
MAXIMUM
MINIMUM
NEW
NATIONAL ELECTRIC CODE
NOT IN CONTRACT
NOT TO SCALE
ON CENTER
OVERCURRENT PROTECTION
POWER CONTROL SYSTEM
PROPERTY LINES
PHOTOVOLTAIC
POLYVINYL CHLORIDE
ROOF, BALLAST
ROOF, FLUSH MOUNT
SCHEDULE
SQUARE INCHES
STAINLESS STEEL
SEE STRUCTURAL DRAWINGS
STANDARD TESTING CONDITIONS
TYPICAL
UNLESS OTHERWISE NOTED
UNINTERRUPTIBLE POWER SUPPLY
VERIFY IN FIELD
VOLT
VOLTAGE AT MAX POWER
VOLTAGE AT OPEN CIRCUIT
WATT
NEMA 3R, RAINTIGHT
A
AC
ACDS
ADA
AFC
ASTM
BESS
BLDG
CLR
CN
CONC
C.O.U
CR
DC
DIA
DIST
EQ
EGC
(E)
EA.
EMT
GALV
GEC
GND
HDG
I
Imp
INVS
Isc
kVA
kW
kWh
LBW
MAX
MIN
(N)
NEC
NIC
NTS
OC
OCP
PCS
PL
PV
PVC
RB
RF
SCH
SQ. IN.
SS
SSD
STC
TYP
UON
UPS
VIF
V
Vmp
Voc
W
3R
ABBREVIATIONS
DESIGN WIND SPEED: 96 MPH
EXPOSURE: B
SNOWLOAD: 0 PSF
WEATHER STATION: POLARIS DATA
DESIGN LOW TEMP: -2°C
2% DRY BULB: 38°C
SDS: 1.023
MOUNTING PLANE HEIGHT(S): 20 FT
BUILDING STORIES: 2/1
CONSTRUCTION TYPE: V-A
OCCUPANCY GROUP: R-2
AUTOMATIC FIRE SPRINKLERS: No
PROJECT INFORMATION
RAIL
STANDOFFS &
FOOTINGS
SOLAR MODULES
AERIAL MAP
SITE NOTES:
·A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS.
·THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES.
·THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS.
·PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26.
·ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S
INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE.
·NO CHANGE TO PARKING OR STRIPING
·PV MODULES ARE TYPE I FIRE RATED AND THE CANOPY STRUCTURE IS OPEN AIR AND NON-HABITABLE.
EQUIPMENT LOCATIONS:
·ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26.
·WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND
NEC TABLES 310.15 (B)(1) AND 310.15 (B)(2) IF RACEWAYS ARE < 7/8" ABOVE THE ROOF.
·JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO NEC 690.34.
·ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT.
·ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC APPLICABLE CODES.
·ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE.
STRUCTURAL NOTES:
·RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE
BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAIL
MANUFACTURER’S INSTRUCTIONS.
·JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL
REQUIREMENTS.
·ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED W/ APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED
CONTRACTOR.
·ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER.
·WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS.
DISCONNECTION AND OVER-CURRENT PROTECTION NOTES:
·DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO
THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS).
·DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH.
·DC DISCONNECT INTEGRATED INTO ROOFTOP DC COMBINER OR INSTALLED WITHIN 6 FT, ACCORDING TO NEC 690.15(B).
·ALL PV CIRCUITS LOCATED OUTSIDE THE ARRAY BOUNDARY OR MORE THAN 3 FT FROM THE POINT OF ENTRY INSIDE A BUILDING SHALL BE LIMITED TO NOT
MORE THAN 30 VOLTS WITHIN 30 SECONDS, CIRCUITS INSIDE THE ARRAY BOUNDARY OR NOT MORE THAN 3 FT FROM THE POINT OF PENETRATION SHALL BE
LIMITED TO NOT MORE THAN 80 VOLTS UPON RAPID SHUT-DOWN INITIATION PER 690.12.
·ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9, AND 240.
WIRING & CONDUIT NOTES:
·ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE
REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING.
·CONDUCTORS SIZED ACCORDING TO NEC 690.8, NEC 690.7.
·ALL CONDUIT MUST ACCOUNT FOR ENVIRONMENTAL CONDITIONS AND THERMAL EXPANSIONS ACCORDING TO NEC 300.7.
·PV WIRE BLACK WIRE MAY BE FIELD-MARKED BY MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING, MARKING TAPE,
TAGGING, OR OTHER APPROVED MEANS.
·MODULE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY.
·RACKING, MID CLIPS, END CLIPS, AND MODULES UL2703 LISTED
·ACCORDING TO NEC 200.7, SYSTEMS DC CONDUCTORS COLORED OR MARKED AS FOLLOWS:
···DC POSITIVE- RED, OR OTHER COLOR EXCLUDING WHITE, GRAY AND GREEN
···DC NEGATIVE- BLACK, OR ANY COLOR EXCLUDING WHITE, GRAY AND GREEN
·AC CONDUCTORS COLORED OR MARKED AS FOLLOWS:
···PHASE A OR L1- BLACK
···PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE
···PHASE C OR L3- BLUE, YELLOW, ORANGE*, OR OTHER CONVENTION
···NEUTRAL- WHITE OR GRAY
*IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [NEC 110.15].
CODES AND STANDARDS
SHEET INDEXBILL OF MATERIALS
NEW PV AND ENERGY STORAGE SYSTEM:
ON ROOF
PV SYSTEM: 259.12 DCkW, 186.2 ACkW, 241.45 CEC ACkW
ENERGY STORAGE SYSTEM: 184.8 ACkW, 523.8 kWH
WILSHIRE MINNIE
1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA
APN #: 014-251-49/014-251-50
BUILDING: IBC 2024
LOCAL BUILDING: CBC 2025
OCCUPANCY GROUP: R-2
ELECTRICAL: NEC 2023
LOCAL ELECTRICAL: CEC 2025
FIRE: CFC 2025
AHJ: CA-CITY OF SANTA ANA
UTILITY: SCE
C100 : COVERSHEET
E100 : ELECTRICAL SITE PLAN
E101 : ELECTRICAL SITE PLAN
E102 : ELECTRICAL SITE PLAN
E200 : ELECTRICAL PLAN VIEWS
E201 : ELECTRICAL PLAN VIEWS
E202 : ELECTRICAL PLAN VIEWS
E300 : ELECTRICAL STRINGING
E301 : ELECTRICAL STRINGING
E302 : ELECTRICAL STRINGING
E303 : ELECTRICAL STRINGING
E400 : ELECTRICAL DETAILS
E401 : ELECTRICAL DETAILS
E500 : ELECTRICAL NOTES
E600 : ONELINE DIAGRAM POI-1
E601 : ONELINE DIAGRAM POI-2
E602 : ONELINE DIAGRAM POI-3
E603 : ONELINE DIAGRAM POI-4
E604 : ONELINE DIAGRAM POI-5
E605 : ONELINE DIAGRAM POI-6
E606 : ONELINE DIAGRAM POI-7
E800 : WARNING LABELS
E801 : WARNING LABELS
E810 : SITE PLACARDS
S100 : STRUCTURAL SITE PLAN
S200 : STRUCTURAL ARRAY DETAIL
S201 : STRUCTURAL ARRAY DETAIL
S202 : STRUCTURAL ARRAY DETAIL
S203 : STRUCTURAL ARRAY DETAIL
S300 : STRUCTURAL SIDE SECTIONS
S400 : STRUCTURAL ATTACHMENT DETAILS
S401 : STRUCTURAL ATTACHMENT DETAILS
S500 : EQUIPMENT PAD
R100 : REFERENCE SHEETS
R101 : REFERENCE SHEETS
R102 : REFERENCE SHEETS
R103 : REFERENCE SHEETS
R104 : REFERENCE SHEETS
R105 : UL9540A
R106 : UL9540A
R107 : UL9540A
MODULES:
(632) QCELLS NORTH AMERICA Q.PEAK DUO BLK ML-G10.C+ 410
OPTIMIZERS:
(632) SOLAREDGE U650
INVERTERS:
(11) SOLAREDGE SE11400H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM]
(8) SOLAREDGE SE7600H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM]
MONITORING:
(19) CELL-B-R05-US-S-S2
BESS:
(54) SOLAREDGE BAT-10K1P
(19) SOLAREDGE HOME NET CARD
(54) SEDG FLOOR MOUNT
RACKING:
FLUSH ROOF: ULTRAFOOT RAFTER - 1 LAG
FLAT ROOF: SNAPNRACK TILT KIT - OMNIBASE
SCOPE OF WORK
INSTALL 259.12 kW-DC OF PV AND 523.8 kWh OF ESS AT SEVEN (7) DIFFERENT INTERCONNECTION POINTS (POIs) AT WILSHIRE MINNIE APARTMENTS:
POI #PV LOCATION PV kW ESS Location ESS
QTY
ESS
kWh INTERCONNECTION LOCATION
1
1201 E WILSHIRE AVE 19.68
1209 3/4 E WILSHIRE AVE UNIT# ELE01 12 116.4 1209 E WILSHIRE AVE UNIT# MTR021209 E WILSHIRE AVE 17.22
1213 E WILSHIRE AVE 17.22
2
1221 E WILSHIRE AVE 17.22
1221 3/4 E WILSHIRE AVE UNIT# ELE01 9 87.3 1221 E WILSHIRE AVE UNIT# MTR02
1225 E WILSHIRE AVE 30.34
3
1229 E WILSHIRE AVE 29.52
1229 3/4 E WILSHIRE AVE UNIT# ELE01 9 87.3 1229 E WILSHIRE AVE UNIT# MTR02
1235 E WILSHIRE AVE 17.22
4 1233 E WILSHIRE AVE 28.70 ESS CONCRETE PAD 6 58.2 1233 E WILSHIRE AVE UNIT# MTR01
5 1401 S MINNIE ST 35.67 1401 S MINNIE ST (WALL MOUNT)6 58.2 1401 S MINNIE ST UNIT# MTR01
6 1403 S MINNIE ST 22.96 1403 S MINNIE ST (WALL MOUNT)6 58.2 1403 S MINNIE ST UNIT# MTR01
7 1425 S MINNIE ST 23.37 1425 S MINNIE ST (WALL MOUNT)6 58.2 1425 S MINNIE ST UNIT# MTR01
TOTALS 259.12 54 524
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
COVER SHEET
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
C100
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#ESTAMP
#SSTAMP
WILSHIRE MINNIE
1209 E WILSHIRE AVE UNIT# MTR02
1209 3/4 E WILSHIRE AVE UNIT# ELE01
1221 E WILSHIRE AVE UNIT# MTR02
1221 3/4 E WILSHIRE AVE UNIT# ELE01
1229 E WILSHIRE AVE UNIT# MTR02
1229 3/4 E WILSHIRE AVE UNIT# ELE01
1233 E WILSHIRE AVE UNIT# MTR01
1401 S MINNIE ST UNIT# MTR01
1403 S MINNIE ST UNIT# MTR01
1425 S MINNIE ST UNIT# MTR01
APN: 014-251-49 / 014-251-50
DEVELOPER: C&C DEVELOPMENT
PL PL PL PL PL
PL
PL
PL
PL
PL
PL PL
PL
PL
PL
PL
PL
PL
PL
PLPLPLPLPLPLPLPLPL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL PL
1209 E WILSHIRE AVE 1213 E WILSHIRE AVE
1221 E WILSHIRE AVE
1225 E WILSHIRE AVE
1229 E WILSHIRE AVE
1233 E WILSHIRE AVE
1401 S MINNIE ST
1409 S MINNIE ST
1413 S MINNIE ST
1421 S MINNIE ST
1235 E WILSHIRE AVE
POI
POI
PO
I
POI
PO
I
POI
POI
POI
PO
I
POI
POI
(N) CONDUIT RUN
(ENTRENCHED ~ 30 FT)
(N) CONDUIT RUN
(ENTRENCHED ~ 10 FT)
(N) CONDUIT RUN
(ENTRENCHED ~ 20 FT)
(N) CONDUIT RUN
(ENTRENCHED ~ 6 FT)
(N) CONDUIT RUN
(ENTRENCHED ~ 10 FT)
1425 S MINNIE ST
1429 S MINNIE ST
S
S
T
A
N
D
A
R
D
A
V
E
MI
N
N
I
E
S
T
E WILSHIRE AVE
(N) CONDUIT RUN
(ENTRENCHED ~ 13 FT)
(N) CONDUIT RUN
(ENTRENCHED ~ 10 FT)
RB03
TL: 5° AZ: 270°
RB04
TL: 5° AZ: 90°
RB05
TL: 5° AZ: 270°
RB06
TL: 5° AZ: 90°
RB07
TL: 5° AZ: 270°
RB08
TL: 5° AZ: 90°
RB09
TL: 5° AZ: 322°
RB10
TL: 5° AZ: 142°
RB11
TL: 5° AZ: 180°
RB12
TL: 5° AZ: 180°
RB13
TL: 5° AZ: 270°
RB14
TL: 5° AZ: 90°
RF01
TL: 10° AZ: 270°
RF02
TL: 10° AZ: 90°
RF03
TL: 10° AZ: 270°
RF04
TL: 10° AZ: 90°
RF05
TL: 19° AZ: 270°
RF06
TL: 19° AZ: 90°
RF07
TL: 15° AZ: 0°
RF08
TL: 15° AZ: 270°
RF09
TL: 15° AZ: 180°
RF10
TL: 15° AZ: 90°
RF11
TL: 10° AZ: 0°
RF12
TL: 10° AZ: 180°
RF13
TL: 10° AZ: 270°
RF14
TL: 10° AZ: 90°
S200
A
S201
A
S201
B
S202
A
S202
B
S203
B
S203
A
1433 S MINNIE ST
1437 S MINNIE ST
FIRE SETBACKS (3' TYP)
ROOF PATHWAY (3' TYP)
4' PERIMETER
SETBACKS
ROOF PATHWAY (3' TYP)
FIRE SETBACKS (3' TYP)
APN #: 014-251-50
APN #: 014-251-49
S203
A
1439 S MINNIE ST
1201 E WILSHIRE AVE
RB01
TL: 5° AZ: 270°
RB02
TL: 5° AZ: 90°
4' PERIMETER
SETBACKS
1403
S MINNIE ST
1229 3/4 E WILSHIRE
AVE UNIT# ELE01
1221 3/4 E WILSHIRE
AVE UNIT# ELE01
1209 3/4 E WILSHIRE
AVE UNIT# ELE01
(N) SOLAR CANOPY
STRUCTURAL COLUMN
DOWN SLOPE
FLUSH FOOTING
RAIL
LEGEND
ATTIC VENT
FLUSH ATTIC VENT
PVC PIPE VENT
SATELLITE DISH
T-VENT
CHIMNEY
FIRE SETBACKS
METAL PIPE VENT
HARDSCAPE
PROPERTY LINEPL
PITCH
2°
X
XX
DETAIL CUT
SHEET NUMBER
X
XX
SECTION CUT
SHEET NUMBER
GENERAL NOTES
RAIL
STANDOFFS &
FOOTINGS
SOLAR MODULES
·ALL WORK SHALL COMPLY WITH ALL STATE AND
LOCAL CODES AND ANY OTHER REGULATING
AUTHORITIES WHICH HAVE AUTHORITY OVER
ANY PORTION OF THE WORK.
·DRAWINGS HAVE BEEN DETAILED IN
COMPLIANCE WITH UL LISTING REQUIREMENTS,
OSFM SOLAR PHOTOVOLTAIC INSTALLATION
REQUIREMENTS, AND BUILDING CODES FOR
THE MATERIALS SPECIFIED. PRIOR TO
COMMENCEMENT OF ANY WORK, THE
CONTRACTOR SHALL VERIFY EXISTING
CONDITIONS AND NOTIFY THE DESIGN
PROFESSIONAL IN RESPONSIBLE CHARGE
FROM SUNRUN OF ANY DISCREPANCIES. ANY
WORK PERFORMED IN CONFLICT WITH THE
CONTRACT DOCUMENTS SHALL BE CORRECTED
AT THE SUBCONTRACTORS SOLE EXPENSE.
·SUBCONTRACTOR INITIATED CHANGES SHALL
BE SUBMITTED IN WRITING TO SUNRUN FOR
APPROVAL BEFORE MAKING ANY CHANGES OR
DEVIATION FROM PLANS BEFORE WRITTEN
APPROVAL FROM SUNRUN PLACES LIABILITY
ON THE SUBCONTRACTOR.
·ALL EQUIPMENT SHALL BE MOUNTED AS
SHOWN. WHERE DETAILS ARE NOT PROVIDED,
CONTRACTOR SHALL USE STANDARD
CONSTRUCTION PRACTICES.
·ALL SURFACES SHALL BE PATCHED AND
PAINTED AROUND NEW DEVICES AND
EQUIPMENT TO MATCH EXISTING FINISHES.
ANY METAL SHAVINGS FROM SITE WORK SHALL
BE CLEANED FROM ALL SURFACES WHERE
OXIDIZED OR CONDUCTIVE METAL SHAVINGS
MY CAUSE RUST, ELECTRICAL SHORT CIRCUITS,
OR OTHER DAMAGE.
·BEAMS OR PURLINS SHALL NOT BE DRILLED
UNLESS AUTHORIZED OR SHOWN IN THE
DRAWINGS.
·APPROVALS FROM BUILDING INSPECTORS
SHALL NOT CONSTITUTE AUTHORITY TO
DEVIATE FROM THE DRAWINGS.
·NO CHANGE TO PARKING OR STRIPING LAYOUT.
·IT IS THE RESPONSIBILITY OF THE INSTALLER
TO ENSURE THAT RACKING SYSTEMS ARE
BUILT PER THE INSTALLATION MANUAL AND
MEET ALL LOCAL BUILDING CODES. IT IS ALSO
THE RESPONSIBILITY OF THE INSTALLER TO
CHECK THE BUILDING FOR STRUCTURAL
ADEQUACY AND MAKE THE FINAL
DETERMINATION ON CONTINUOUS ARRAY
LENGTH TO ACCOUNT FOR THERMAL
EXPANSION AND CONTRACTION OF THE
SYSTEM.
·FOR BALLASTED RACKING THE CONTRACTOR
SHALL FIELD VERIFY THE ROOF IS SLOPED AT
1/4" PER FOOT OR MORE TO LIMIT EFFECTS OF
PONDING. IF ROOF SLOPE IS LESS THAN 1/4"
PER FOOT, THE CONTRACTOR SHALL NOTIFY
THE SEOR AND/OR SUNRUN PRIOR TO MOVING
FORWARD WITH CONSTRUCTION.
CANOPY FOOTING
XX##
TL: ##° AZ: ###°
ROOF IDENTIFIER
MOUNTING INDEX
MOUNTING TYPE
TILT
AZUMUTH
ROOF FRAMING
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
STRUCTURAL PLAN
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
S100
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
SCALE: 1" = 40'
#SSTAMP
IFC SECTION 1205.2 ACCESS
PATHWAYS
BLDG
NUMBER
PLAN VIEW
AREA (sqft)
MODULE
COUNT
COVERAGE
(%)
1225 3023.5 74 53.2%
1229 3036.7 72 51.5%
1235 2045.1 42 44.6%
1401 4332.9 87 43.6%
1425 3711.3 57 33.4%
Totals 16150 332
WILSHIRE MINNIE
1209 E WILSHIRE AVE UNIT# MTR02
1209 3/4 E WILSHIRE AVE UNIT# ELE01
1221 E WILSHIRE AVE UNIT# MTR02
1221 3/4 E WILSHIRE AVE UNIT# ELE01
1229 E WILSHIRE AVE UNIT# MTR02
1229 3/4 E WILSHIRE AVE UNIT# ELE01
1233 E WILSHIRE AVE UNIT# MTR01
1401 S MINNIE ST UNIT# MTR01
1403 S MINNIE ST UNIT# MTR01
1425 S MINNIE ST UNIT# MTR01
APN: 014-251-49 / 014-251-50
DEVELOPER: C&C DEVELOPMENT
(N) SOLAR CANOPY
STRUCTURAL COLUMN
LEGEND
ATTIC VENT
FLUSH ATTIC VENT
PVC PIPE VENT
SATELLITE DISH
T-VENT
CHIMNEY
FIRE SETBACKS
METAL PIPE VENT
HARDSCAPE
PROPERTY LINEPL
CLAMPING ZONES
RAIL
STANDOFFS &
FOOTINGS
SOLAR MODULES
XX##
TL: ##° AZ: ###°
ROOF IDENTIFIER
MOUNTING INDEX
MOUNTING TYPE
TILT
AZUMUTH
DOWN SLOPE
FLUSH FOOTING
RAIL
PITCH
2°
CANOPY FOOTING
Q.PEAK DUO BLK ML-G10.C+ 410
[DCC]
LANDSCAPE CLAMP ZONE
0.79" TO 7.87"
0.8
18.9
19.7
Q.PEAK DUO BLK ML-G10.C+ 410
[DCC]
PORTRAIT CLAMP ZONE
0.79" TO 19.7"
0.8
7.1
7.9
ROOF FRAMING
MAX DISTRIBUTED LOAD: 3 PSF
SNOW LOAD: 0 PSF
WIND SPEED: 96 MPH
LAG SCREWS:
5/16"x3.5": 2.5" MIN EMBEDMENT
NOTE:
INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND
SLOPED SPANS, AND NOTIFY E.O.R. OF ANY
DISCREPANCIES BEFORE PROCEEDING.
ADDITIONAL DETAILS
WINDZONES
1209 E WILSHIRE AVE
1213 E WILSHIRE AVE
RB03
TL: 5° AZ: 270°
RB04
TL: 5° AZ: 90°
RB05
TL: 5° AZ: 270°
RB06
TL: 5° AZ: 90°
1201 E WILSHIRE AVE
RB01
TL: 5° AZ: 270°
RB02
TL: 5° AZ: 90°
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
STRUCTURAL DETAIL
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
S200
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#SSTAMP
SCALE: 1/8" = 1'-0"
ADDRESS 1201,1209 & 1213 DETAIL • POI-1A
78
'
-
1
"
37'-5"
77
'
-
3
"
37'-8"
77
'
-
6
"
36'-11"
A
S300
7'
-
4
"
14
'
-
1
1
"
4'-8"5'-2"
POI-1 ROOF SCHEDULE
ADDRESS LABEL RACKING TILT (DEG)AZIMUTH
(DEG)
BUILDING
HEIGHT (FT)
MODULE
COUNT
MODULE AREA (SQFT)KW DC
1201 RB01 FIXED TILT 5°270°20 20 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]422.4 8.20
1201 RB02 FIXED TILT 5°90°20 28 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]591.4 11.48
1209 RB03 FIXED TILT 5°270°20 21 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]443.5 8.61
1209 RB04 FIXED TILT 5°90°20 21 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]443.5 8.61
1213 RB05 FIXED TILT 5°270°20 17 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]359.1 6.97
1213 RB06 FIXED TILT 5°90°20 25 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]528.0 10.25
Totals 132 2788 54
6'
T
Y
P
.
WILSHIRE MINNIE
1209 E WILSHIRE AVE UNIT# MTR02
APN: 014-251-49
DEVELOPER:
C&C DEVELOPMENT
2"x4" RAFTERS @ 24" O.C. TYP.2"x4" RAFTERS @ 24" O.C. TYP.2"x4" RAFTERS @ 24" O.C. TYP.
(N) SOLAR CANOPY
STRUCTURAL COLUMN
LEGEND
ATTIC VENT
FLUSH ATTIC VENT
PVC PIPE VENT
SATELLITE DISH
T-VENT
CHIMNEY
FIRE SETBACKS
METAL PIPE VENT
HARDSCAPE
PROPERTY LINEPL
CLAMPING ZONES
RAIL
STANDOFFS &
FOOTINGS
SOLAR MODULES
XX##
TL: ##° AZ: ###°
ROOF IDENTIFIER
MOUNTING INDEX
MOUNTING TYPE
TILT
AZUMUTH
DOWN SLOPE
FLUSH FOOTING
RAIL
PITCH
2°
CANOPY FOOTING
Q.PEAK DUO BLK ML-G10.C+ 410
[DCC]
LANDSCAPE CLAMP ZONE
0.79" TO 7.87"
0.8
18.9
19.7
Q.PEAK DUO BLK ML-G10.C+ 410
[DCC]
PORTRAIT CLAMP ZONE
0.79" TO 19.7"
0.8
7.1
7.9
ROOF FRAMING
MAX DISTRIBUTED LOAD: 3 PSF
SNOW LOAD: 0 PSF
WIND SPEED: 96 MPH
LAG SCREWS:
5/16"x3.5": 2.5" MIN EMBEDMENT
NOTE:
INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND
SLOPED SPANS, AND NOTIFY E.O.R. OF ANY
DISCREPANCIES BEFORE PROCEEDING.
ADDITIONAL DETAILS
WINDZONES
1229 E WILSHIRE AVE
1401 S MINNIE ST
1235 E WILSHIRE AVE
RB10
TL: 5° AZ: 142°
RF03
TL: 10° AZ: 270°
RF04
TL: 10° AZ: 90°
RF05
TL: 19° AZ: 270°
RF06
TL: 19° AZ: 90°
RF08
TL: 15° AZ: 270°
S201
B
S202
A
1229 3/4 E WILSHIRE
AVE UNIT# ELE01
1221 E WILSHIRE AVE
1225 E WILSHIRE AVE
RB07
TL: 5° AZ: 270°
RB08
TL: 5° AZ: 90°
RF01
TL: 10° AZ: 270°
RF02
TL: 10° AZ: 90°
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
STRUCTURAL DETAIL
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
S201
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#SSTAMP
SCALE: 1/8" = 1'-0"
ADDRESS 1221,1225 DETAIL • POI-2A SCALE: 1/8" = 1'-0"
ADDRESS 1229,1235 DETAIL • POI-3B
76
'
-
9
"
37'-6"
76
'
-
9
"
37'-5"
6'
T
Y
P
.
2'-4"
3'
-
1
"
7'
-
1
"
5'-7"
76
'
-
3
"
37'-9"
1'
-
8
"
3'
-
1
"
4'
-
2
"
3'
-
4
"
A
S300
B
S300
2"x6" RAFTERS
@ 24" O.C. TYP.
2"x6" RAFTERS @ 24" O.C. TYP.
2"x6" RAFTERS @ 24" O.C. TYP.
POI-2 ROOF SCHEDULE
ADDRESS LABEL RACKING TILT (DEG)AZIMUTH (DEG)BUILDING HEIGHT
(FT)
MODULE COUNT MODULE AREA (SQFT)KW DC
1221 RB07 FIXED TILT 5°270°20 25 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]528.0 10.25
1221 RB08 FIXED TILT 5°90°20 17 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]359.1 6.97
1225 RF01 FLUSH MOUNT 10°270°20 32 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]675.9 13.12
1225 RF02 FLUSH MOUNT 10°90°20 42 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]887.1 17.22
Totals 116 2450 48
POI-3 ROOF SCHEDULE
ADDRESS LABEL RACKING TILT (DEG)AZIMUTH (DEG)BUILDING HEIGHT
(FT)
MODULE COUNT MODULE AREA (SQFT)KW DC
1229 RF03 FLUSH MOUNT 10°270°20 40 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]844.8 16.40
1229 RF04 FLUSH MOUNT 10°90°20 32 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]675.9 13.12
1235 RF05 FLUSH MOUNT 19°270°20 20 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]422.4 8.20
1235 RF06 FLUSH MOUNT 19°90°20 22 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]464.7 9.02
Totals 114 2408 47
6'
T
Y
P
.
WILSHIRE MINNIE
1221 E WILSHIRE AVE UNIT# MTR02
1229 E WILSHIRE AVE UNIT# MTR02
APN: 014-251-49
DEVELOPER:
C&C DEVELOPMENT
6'
T
Y
P
.
2"x4" RAFTERS
@ 24" O.C. TYP.
(N) SOLAR CANOPY
STRUCTURAL COLUMN
LEGEND
ATTIC VENT
FLUSH ATTIC VENT
PVC PIPE VENT
SATELLITE DISH
T-VENT
CHIMNEY
FIRE SETBACKS
METAL PIPE VENT
HARDSCAPE
PROPERTY LINEPL
CLAMPING ZONES
RAIL
STANDOFFS &
FOOTINGS
SOLAR MODULES
XX##
TL: ##° AZ: ###°
ROOF IDENTIFIER
MOUNTING INDEX
MOUNTING TYPE
TILT
AZUMUTH
DOWN SLOPE
FLUSH FOOTING
RAIL
PITCH
2°
CANOPY FOOTING
Q.PEAK DUO BLK ML-G10.C+ 410
[DCC]
LANDSCAPE CLAMP ZONE
0.79" TO 7.87"
0.8
18.9
19.7
Q.PEAK DUO BLK ML-G10.C+ 410
[DCC]
PORTRAIT CLAMP ZONE
0.79" TO 19.7"
0.8
7.1
7.9
ROOF FRAMING
MAX DISTRIBUTED LOAD: 3 PSF
SNOW LOAD: 0 PSF
WIND SPEED: 96 MPH
LAG SCREWS:
5/16"x3.5": 2.5" MIN EMBEDMENT
NOTE:
INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND
SLOPED SPANS, AND NOTIFY E.O.R. OF ANY
DISCREPANCIES BEFORE PROCEEDING.
ADDITIONAL DETAILS
WINDZONES
1233 E WILSHIRE AVE
1401 S MINNIE ST
1235 E WILSHIRE AVE
RB09
TL: 5° AZ: 322°
RB10
TL: 5° AZ: 142°
1401 S MINNIE ST
RB10
TL: 5° AZ: 142°
RF07
TL: 15° AZ: 0°
RF08
TL: 15° AZ: 270°
RF09
TL: 15° AZ: 180°
RF10
TL: 15° AZ: 90°
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
STRUCTURAL DETAIL
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
S202
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#SSTAMP
SCALE: 3/32" = 1'-0"
ADDRESS 1233 DETAIL • POI-4A SCALE: 3/32" = 1'-0"
ADDRESS 1401 DETAIL • POI-5B
116
'
-
5
"
37'
7'-1
0
"
4'-1
1
"
A
S300
B
S300
1'-9"
9'-1"
10
"
1'
-
2
"
1'
10'-5"
8'-3"
6' TYP.
3'-6"
POI-4 ROOF SCHEDULE
ADDRESS LABEL RACKING TILT (DEG)AZIMUTH (DEG)BUILDING HEIGHT
(FT)
MODULE COUNT MODULE AREA (SQFT)KW DC
1233 RB09 FIXED TILT 5°322°20 44 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]929.3 18.04
1233 RB10 FIXED TILT 5°142°20 26 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]549.1 10.66
Totals 70 1478 29
POI-5 ROOF SCHEDULE
ADDRESS LABEL RACKING TILT (DEG)AZIMUTH (DEG)BUILDING HEIGHT
(FT)
MODULE COUNT MODULE AREA (SQFT)KW DC
1401 RF07 FLUSH MOUNT 15°0°20 39 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]823.7 15.99
1401 RF08 FLUSH MOUNT 15°270°20 5 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]105.6 2.05
1401 RF09 FLUSH MOUNT 15°180°20 39 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]823.7 15.99
1401 RF10 FLUSH MOUNT 15°90°20 4 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]84.5 1.64
Totals 87 1838 36
6' T
Y
P
.
2"x6" RAFTERS @ 24" O.C. TYP.
WILSHIRE MINNIE
1233 E WILSHIRE AVE UNIT# MTR01
1401 S MINNIE ST UNIT# MTR01
APN: 014-251-49
DEVELOPER:
C&C DEVELOPMENT
2"x4" RAFTERS @ 24" O.C. TYP.
(N) SOLAR CANOPY
STRUCTURAL COLUMN
LEGEND
ATTIC VENT
FLUSH ATTIC VENT
PVC PIPE VENT
SATELLITE DISH
T-VENT
CHIMNEY
FIRE SETBACKS
METAL PIPE VENT
HARDSCAPE
PROPERTY LINEPL
CLAMPING ZONES
RAIL
STANDOFFS &
FOOTINGS
SOLAR MODULES
XX##
TL: ##° AZ: ###°
ROOF IDENTIFIER
MOUNTING INDEX
MOUNTING TYPE
TILT
AZUMUTH
DOWN SLOPE
FLUSH FOOTING
RAIL
PITCH
2°
CANOPY FOOTING
Q.PEAK DUO BLK ML-G10.C+ 410
[DCC]
LANDSCAPE CLAMP ZONE
0.79" TO 7.87"
0.8
18.9
19.7
Q.PEAK DUO BLK ML-G10.C+ 410
[DCC]
PORTRAIT CLAMP ZONE
0.79" TO 19.7"
0.8
7.1
7.9
ROOF FRAMING
MAX DISTRIBUTED LOAD: 3 PSF
SNOW LOAD: 0 PSF
WIND SPEED: 96 MPH
LAG SCREWS:
5/16"x3.5": 2.5" MIN EMBEDMENT
NOTE:
INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND
SLOPED SPANS, AND NOTIFY E.O.R. OF ANY
DISCREPANCIES BEFORE PROCEEDING.
ADDITIONAL DETAILS
WINDZONES
RB11
TL: 5° AZ: 180°
RB12
TL: 5° AZ: 180°
RB13
TL: 5° AZ: 270°
RB14
TL: 5° AZ: 90°
1403
S MINNIE ST
1425 S MINNIE ST
RF11
TL: 10° AZ: 0°
RF12
TL: 10° AZ: 180°
RF13
TL: 10° AZ: 270°
RF14
TL: 10° AZ: 90°
POI-7 ROOF SCHEDULE
ADDRESS LABEL RACKING TILT (DEG)AZIMUTH (DEG)BUILDING
HEIGHT (FT)
MODULE COUNT MODULE AREA (SQFT)KW DC
1425 RF11 FLUSH MOUNT 10°0°20 16 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]337.9 6.56
1425 RF12 FLUSH MOUNT 10°180°20 23 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]485.8 9.43
1425 RF13 FLUSH MOUNT 10°270°20 8 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]169.0 3.28
1425 RF14 FLUSH MOUNT 10°90°20 10 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]211.2 4.10
Totals 57 1204 23
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
STRUCTURAL DETAIL
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
S203
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#SSTAMP
SCALE: 3/32" = 1'-0"
ADDRESS 1403 DETAIL • POI-6A
82'-9"
57
'
-
1
0
"
8'
-
8
"
8'-9"
SCALE: 3/32" = 1'-0"
ADDRESS 1425 DETAIL • POI-7B
80'-10"
56
'
-
1
1
"
5'
-
1
"
8'
-
3
"
4'-6"
1'-9"
1'-1"
4'-2"
4'
-
2
"
7"
POI-6 ROOF SCHEDULE
ADDRESS LABEL RACKING TILT (DEG)AZIMUTH (DEG)BUILDING
HEIGHT (FT)
MODULE COUNT MODULE AREA (SQFT)KW DC
1403 RB11 FIXED TILT 5°180°20 18 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]380.2 7.38
1403 RB12 FIXED TILT 5°180°20 15 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]316.8 6.15
1403 RB13 FIXED TILT 5°270°20 6 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]126.7 2.46
1403 RB14 FIXED TILT 5°90°20 17 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]359.1 6.97
Totals 56 1183 23
B
S300
A
S300
6' TYP.
6' TYP.
2"x6" RAFTERS @ 24" O.C. TYP.
WILSHIRE MINNIE
1403 S MINNIE ST UNIT# MTR01
1425 S MINNIE ST UNIT# MTR01
APN: 014-251-49 / 014-251-50
DEVELOPER:
C&C DEVELOPMENT
2"x4" RAFTERS @ 24" O.C. TYP.
(N) SOLAR CANOPY
STRUCTURAL COLUMN
LEGEND
ATTIC VENT
FLUSH ATTIC VENT
PVC PIPE VENT
SATELLITE DISH
T-VENT
CHIMNEY
FIRE SETBACKS
METAL PIPE VENT
HARDSCAPE
PROPERTY LINEPL
CLAMPING ZONES
RAIL
STANDOFFS &
FOOTINGS
SOLAR MODULES
XX##
TL: ##° AZ: ###°
ROOF IDENTIFIER
MOUNTING INDEX
MOUNTING TYPE
TILT
AZUMUTH
DOWN SLOPE
FLUSH FOOTING
RAIL
PITCH2°
CARPORT FOOTING
Q.PEAK DUO BLK ML-G10.C+ 410
[DCC]
LANDSCAPE CLAMP ZONE
0.79" TO 7.87"
0.8
18.9
19.7
Q.PEAK DUO BLK ML-G10.C+ 410
[DCC]
PORTRAIT CLAMP ZONE
0.79" TO 19.7"
0.8
7.1
7.9
ROOF FRAMING
MAX DISTRIBUTED LOAD: 3 PSF
SNOW LOAD: 0 PSF
WIND SPEED: 96 MPH
LAG SCREWS:
5/16"x3.5": 2.5" MIN EMBEDMENT
NOTE:
INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND
SLOPED SPANS, AND NOTIFY E.O.R. OF ANY
DISCREPANCIES BEFORE PROCEEDING.
ADDITIONAL DETAILS
WINDZONES
BLDG 1425
BLDG 1429
RF11
TL: 10° AZ: 0°
RF12
TL: 10° AZ: 180°RF13
TL: 10° AZ: 270°
RF14
TL: 10° AZ: 90°
RF15
TL: 10° AZ: 270°
RF16
TL: 10° AZ: 90°RF17
TL: 10° AZ: 0°
RF18
TL: 10° AZ: 180°
C:\USERS\EMILIANO.MORALES\DESKTOP\WORKING PROJECTS\1235_WILSHIRE_MINNIE\CD100\WILSHIRE MINNIE_WORKINGDOCS_V0\WILSHIRE MINNIE.DWG
STRUCTURAL DETAIL
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
PROJECT DETAILS:
PV SYSTEM:
·355.88 kW DC
·250.8 kW AC
·331.612 CEC AC
ENERGY STORAGE:
·243.2 kW AC
·756.6 kWH
S204
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER: FINS_TM
ORIGINAL
CONTRACT NUMBER:
3003197607
PJT #: PROP-001235
SCALE: 1/8" = 1'-0"
BLDG 1425,1429 DETAIL • POI-10 & POI-11A
4'-2"
5'
-
1
"
4'
-
1
"
3'7'
-
5
"
4'-2"
4'-6"
1'-10"
8'
-
5
"
4'-1"
4'
-
6
"
3'-7"
6'TYP.B
S300
2"x6" RAFTERS @ 24" O.C. TYP.
2"x6" RAFTERS @ 24" O.C. TYP.
POI-10 ROOF SCHEDULE
BLDG LABEL RACKING TILT (DEG)AZIMUTH (DEG)BUILDING HEIGHT (FT)MODULE COUNT MODULE AREA (SQFT)KW DC
1425 RF11 FLUSH 10°0°20 24 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]506.9 9.84
1425 RF12 FLUSH 10°180°20 26 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]549.1 10.66
1425 RF13 FLUSH 10°270°20 8 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]169.0 3.28
1425 RF14 FLUSH 10°90°20 10 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]211.2 4.10
Totals 68 1436.2 27.9
POI-11 ROOF SCHEDULE
BLDG LABEL RACKING TILT (DEG)AZIMUTH (DEG)BUILDING HEIGHT (FT)MODULE COUNT MODULE AREA (SQFT)KW DC
1429 RF15 FLUSH 10°270°20 8 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]169.0 3.28
1429 RF16 FLUSH 10°90°20 10 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]211.2 4.10
1429 RF17 FLUSH 10°0°20 20 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]422.4 8.20
1429 RF18 FLUSH 10°180°20 26 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]549.1 10.66
Totals 64 1351.7 26.2
80'-4"
80'-10"
REVIEWED FOR STRUCTURAL
6/26/25
PARAPET
ROOF FRAMING STRUCTURE
2"x4" @ 24" O.C. TYP.20'
BUILDING
HEIGHT
FINISHED GRADE
S401
C
NOTE: DETAILS ARE APPROXIMATE AND
ARE FOR SCHEMATIC PURPOSES ONLY
4'
FIRE SETBACKS
A STRUCTURAL SIDE SECTION - OMNIBASE TILT-KIT
NTS
11.2
6.1 5°
56.9
14.9
8.3
SOLAR MODULE
OMNISHIELD
OMNIBASE TILT-KIT
S400
C
NOTE: DETAILS ARE APPROXIMATE AND
ARE FOR SCHEMATIC PURPOSES ONLY
FINISHED GRADE
SE
E
T
A
B
L
E
SOLAR MODULE
5'-5 1/2" (TYP.)
3'-5 1/2" (TYP.)
3/4"
6 7/8" (TYP.)
(N) ULTRAFOOT RAFTER - 1 LAG ATTACHMENT
B STRUCTURAL SIDE SECTIONS - ULTRAFOOT
NTS
SEE TABLE
(E) LBW
(E) CARPENTER TRUSS
2"x6" @ 24 O.C. TYP.
RACKING SPAN TABLES
PORTRAIT LANDSCAPE
SPANS [IN] / CANTILEVER [IN]SPANS [IN] / CANTILEVER [IN]
ROOF PITCH BUILDING
HEIGHT INTERIOR EDGE CORNER INTERIOR EDGE CORNER
10 20 72 / 24 72 / 24 72 / 24 96 / 32 72 / 24 72 / 24
NOTE: SPAN TABLES ARE BASED ON 5/16“Ø LAG SCREW WITH AND EFFECTIVE EMBEDMENT OF 2-1/2“ INTO DOUGLAS FIR SUBSTRATE.
INSTALLATIONS INTO ALTERNATE SUBSTRATES THE SPAN LENGTHS IDENTIFIED IN THE “SPAN TABLES“ SHALL BE REDUCED
ACCORDING TO THE MORE RESTRICTIVE FORMULAS PROVIDED ON PAGE 3 OF THE SNAPNRACK REPORT # 2017-03227.11
EMBEDDED
THROUGH
FRAMING
EMBEDDED
THROUGH
FRAMING
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
STRUCTURAL SIDE SECTIONS
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
S300
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#SSTAMP
WILSHIRE MINNIE
1209 E WILSHIRE AVE UNIT# MTR02
1221 E WILSHIRE AVE UNIT# MTR02
1229 E WILSHIRE AVE UNIT# MTR02
1233 E WILSHIRE AVE UNIT# MTR01
1401 S MINNIE ST UNIT# MTR01
1403 S MINNIE ST UNIT# MTR01
1425 S MINNIE ST UNIT# MTR01
APN: 014-251-49 / 014-251-50
DEVELOPER:
C&C DEVELOPMENT
ULTRAFOOT FLIP CLAMP
TAPPED
ULTRAFOOT FLIP CLAMP
THRU
ULTRAFOOT BASE
ANCHOR
ULTRA RAIL SPRING
3.750
5/16"∅-18 X 1", SS
BOLT, WIDE FLANGE, RECESSED
BUTYL PAD
2.180
EXPLODED
TOP
ROOF RAFTER, TYP.
RAFTER ATTACHMENT DETAIL
SECTION VIEW
ROOF DECKING, TYP.
MIN 2 1/2"
EMBEDMENT
MODULE HEIGHT MAX:
UR-40 = 4 1/2"
UR-45 = 4 1/2"
UR-60 = 5 1/8"
(X1) 5/16"∅ S.S. LAG SCREW
ULTRAFOOT
ANCHOR
SNAPNRACK, ULTRA RAIL
FASTENER HEIGHT
OFF ROOF:
5/16"
C SNAPNRACK, ULTRA RAIL ULTRAFOOT
NTS
FASTENER CONFIGURATIONS
(X2) DECKANCHORS
INTO WOOD DECK
(X1) LAG INTO
RAFTER
UR-40 RAIL | UR-45 RAIL | UR-60 RAIL
FOR USE WITH SNAPNRACK ULTRA SERIES RAILS
2 1 4"
1 1 2"
1 1 2"
1 5 8"1 3
4 "
1 1 2"
FOR SNAPNRACK ENGINEERING TO APPLY, THE EMBEDMENT
CRITERIA SHOWN HEREIN MUST BE MET (IF CRITERIA CANNOT
BE MET OR SPANS ARE NOT SUFFICIENT, CONTACT SNAPNRACK
FOR SUPPORT):
REFER TO SNAPNRACK INSTALLATION MANUAL FOR 5/16"Ø
HARDWARE TORQUE SPECIFICATIONS. REFER TO
MANUFACTUER SPECIFICATIONS FOR OTHER FASTENER TORQUE
REQUIREMENTS.
B REDUCED SPACING AND OVERHANG DETAIL
NTS
NOTE: IF ARRAY (EXCLUDING SKIRT) IS
WITHIN 12" BOUNDARY REGION OF ANY
ROOF PLANE EDGES (EXCEPT VALLEYS),
THEN ATTACHMENTS NEED TO BE ADDED
AND OVERHANG REDUCED WITHIN THE
12" BOUNDARY REGION ONLY AS
FOLLOWS:
·ALLOWABLE ATTACHMENT SPACING
INDICATED ON PLANS TO BE
REDUCED BY 50% (REFER TO TABLE
ABOVE)
·ALLOWABLE OVERHANG INDICATED
ON PLANS TO BE 1/5TH OF
ALLOWABLE ATTACHMENT SPACING
INDICATED ON PLANS (REFER TO
TABLE ABOVE)
12" BOUNDARY
12" SETBACK DOES
NOT APPLY TO
VALLEYS
48" BOUNDARY
·ALLOWABLE ATTACHMENT
SPACING INDICATED ON PLANS
TO BE REDUCED BY 50% (REFER
TO TABLE ABOVE)
·ALLOWABLE OVERHANG
INDICATED ON PLANS TO BE
1/5TH OF ALLOWABLE
ATTACHMENT SPACING
INDICATED ON PLANS (REFER TO
TABLE ABOVE)
PITCHED/SLOPED ROOFS - REDUCED SPACING AND OVERHANG DETAIL FOR
12" BOUNDARY REGION
FLAT ROOFS - REDUCED SPACING AND OVERHANG DETAIL FOR 48"
BOUNDARY REGION
C ULTRA RAIL MID CLAMP
NTS
1.
4
1
1.57
1.29
1.
3
3
.9
4
1
1.75
.1
9
.33
1.
4
8
.57
SNAPNRACK ULTRA END CLAMP,
FITS 30MM - 46MM MODULE HEIGHTS
"RAIL END OVERHANG"
DISTANCE FROM RAIL END
TO OUTER ROOF ATTACHMENT CENTER.
NOT TO EXCEED 34% OF ALLOWABLE SPAN
STRUCTURAL MEMBER
"RAIL SPAN" DISTANCE BETWEEN
CENTERS OF TWO ROOF ATTACHMENTS
DETAIL A:
SNAPNRACK, ULTRA RAIL END CLAMP
BA
SNAPNRACK ULTRA MID CLAMP,
FITS 30MM - 46MM MODULE HEIGHTS
SNAPNRACK, ULTRA RAIL
PV MODULE, TYP.
SNAPNRACK, ULTRA RAIL
DETAIL B:
SNAPNRACK, ULTRA RAIL MID CLAMP
DETAIL C:
PV MODULE FRAME, TYP.
SNAPNRACK, UNIVERSAL END CLAMP.
MODULE HEIGHT AGNOSTIC AND
HIDDEN BENEATH MODULES
SNAPNRACK, ULTRA RAIL
SNAPNRACK, UNIVERSAL END CLAMP
C
PV MODULE, TYP.
3 4" MODULE SPACING
PV MODULE, TYP.
SNAPNRACK, ULTRA RAIL
OVERVIEW OF THE SNAPNRACK ULTRA RAIL
SYSTEM INSTALLED ON A TYPICAL ROOF
REFER TO SPECIFIC "ATTACHMENT DETAIL"
FOR DETAILS ON ATTACHING AND
WATERPROOFING THE VARIOUS
SNAPNRACK ROOF ATTACHMENT PRODUCTS
REFER TO SPECIFIC "COMPONENT DETAIL"
FOR DETAILS ON VARIOUS SNAPNRACK
ACCESSARY AND COMPONENT PRODUCTS
BOTH THE SNAPNRACK, UNIVERSAL END
CLAMP AND SNAPNRACK, ADJUSTABLE END
CLAMP CAN BE USED ON END MODULES
MODULES MAY BE CLAMPED ON SHORT OR
LONG SIDE PER MODULE MANUFACTURER
REQUIREMENTS
RAILS MAY BE MOUNTED UP/DOWN OR
ACROSS THE SLOPE OF THE ROOF
REFER TO SNAPNRACK INSTALLATION
SPECIFICATIONS
SNAPNRACK, ADJUSTABLE
END CLAMP. SELECT TO
MATCH MODULE HEIGHT
PV MODULE, TYP.
MANUAL FOR 5/16" Ø HARDWARE TORQUE
SNAPNRACK, MID CLAMP.
SELECT TO MATCH MODULE HEIGHT
"MODULE OVERHANG"
SNAPNRACK, ULTRA RAIL DISTANCE FROM RAIL SIDE TO MODULE EDGE.
NOT TO EXCEED 25% OF MODULE LENGTH OR
MODULE MANUFACTURER RECOMMENDATIONS
SNAPNRACK, ULTRA RAIL
END CAP, OPTIONAL
ROOFING MATERIAL,
COMP SHINGLE SHOWN, TYP.
ROOF SHEATHING AND
UNDERLAYMENT MATERIAL, TYP.
STRUCTURAL MEMBER,
WOODEN RAFTER SHOWN, TYP.
SNAPNRACK ROOF ATTACHMENT, VAIRES WITH
ROOF TYPE. REFER TO SPECIFIC "ATTACHMENT DETAIL"
FOR ATTACHMENT & WATERPROOFING DETAILS
BIN:
ALL
A ULTRA RAIL, SYSTEM OVERVIEW ULTRA MIDS & ENDS
NTS
UR-40 RAIL | UR-45 RAIL | UR-60 RAIL
FOR USE WITH SNAPNRACK ULTRA SERIES RAILS
2 1 4"
1 1 2"
1 1 2"
1 5 8"1 3
4 "
1 1 2"
.60 1.50
1.56 .29
35°
54°.96
.90
FLANGE LENGTH
(FLAT SURFACE)
.39 - 1.21
[10.0 - 30.7]
FLANGE THICKNESS
.05 - .10
[1.2 - 2.5]
MIN BOX WIDTH
.22
[5.5]
MODULE FRAME GEOMETRY REQUIREMENTS
.85
D ULTRA RAIL UNIVERSAL END CLAMP
NTS
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
RACKING ATTACHMENT
DETAILS
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
S400
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#SSTAMP
WILSHIRE MINNIE
1221 E WILSHIRE AVE UNIT# MTR02
1229 E WILSHIRE AVE UNIT# MTR02
1401 S MINNIE ST UNIT# MTR01
1425 S MINNIE ST UNIT# MTR01
APN: 014-251-49 / 014-251-50
DEVELOPER:
C&C DEVELOPMENT
C ULTRA RAIL MID CLAMP
NTS
1.
4
1
1.57
1.29
1.
3
3
.9
4
1
1.75
.1
9
.33
1.
4
8
.57
.60 1.50
1.56 .29
35°
54°.96
.90
FLANGE LENGTH
(FLAT SURFACE)
.39 - 1.21
[10.0 - 30.7]
FLANGE THICKNESS
.05 - .10
[1.2 - 2.5]
MIN BOX WIDTH
.22
[5.5]
MODULE FRAME GEOMETRY REQUIREMENTS
.85
D ULTRA RAIL UNIVERSAL END CLAMP
NTS
C OMNIBASE WITH STANDOFF TO RAFTER
NTS
*THE SNAPNRACK OMNISHIELD CAN
BE USED TO CHEMICALLY FLASH LOW
SLOPE ROOF APPLICATIONS.
OMNISHIELD
SNAPNRACK ULTRA RAIL STANDARD STANDOFF
ON OMNIBASE FOR MOUNTING TO VARIOUS
ROOF TYPES
REFER TO SNAPNRACK ENGINEERING CHARTS
FOR APPLICABLE RAIL SPANS. "BIN" NUMBER ON
CHART SHOULD MATCH "BIN" NUMBER ON THIS
DRAWING
5 16"Ø S.S. LAG SCREW MUST EMBED A MIN. OF
212" INTO STRUCTURAL MEMBER FOR
SNAPNRACK ENGINEERING TO APPLY
REFER TO SNAPNRACK INSTALLATION MANUAL
SNAPNRACK OMNIBASE CAN MOUNT IN ANY
ORIENTATION ON THE ROOF AND RAILS CAN
MOUNT ON ANY SIDE OF THE STANDOFF POST
FOR ADDITTIONAL LEVELING DETAILS, REFER TO
SNAPNRACK DETAIL DRAWINGS SNR-DC-00334
AND SNR-DC-00447
FOR 5 16"Ø HARDWARE TORQUE SPECIFICATIONS
SNAPNRACK STANDOFF,
LENGTH VARIES
5 16"Ø S.S. LAG SCREW WITH
S.S. FLAT WASHER. CHOOSE
LENGTH FOR PROPER EMBEDMENT
SNAPNRACK, OMNIBASE
EXPLODED
SNAPNRACK, UR STANDOFF
CLAMP ASSEMBLY. VARIES
FOR FLUSH AND TILT APPLICATIONS
SNAPNRACK, ULTRA RAIL
(UR-40 SHOWN)
STRUCTURAL MEMBER,
WOOD RAFTER, TYP.
INSTALLED
*FLASH BASE APPROPRIATELY
FOR THE APPLICATION, REFER TO
SNAPNRACK INSTALLATION MANUAL
ROOF DECKING, TYP.
SNAPNRACK, ULTRA RAIL
(UR-40 SHOWN)
212" MIN. EMBEDMENT
INTO WOOD RAFTER
FOR SNAPNRACK
ENGINEERING TO APPLY ATTACHMENT DETAIL
STRUCTURAL MEMBER,
WOOD RAFTER, TYP.
5 16"Ø S.S. LAG SCREW WITH
S.S. FLAT WASHER. CHOOSE
LENGTH FOR PROPER EMBEDMENT
7" STANDOFF SHOWN,
LENGTH VARIES
MODULE HEIGHT OFF ROOF, RANGE:
(SHOWN FOR 7" STANDOFF,
ADJUST PER STANDOFF LENGTH)
ROOF DECKING, TYP.
BASE HEIGHT:
.70
3.00
4.00
OMNIBASE, TOP
OMNIBASE
UR-40: 73 4" - 87 8"
UR-60: 83 8" - 912"
THE SNAPNRACK TILT-MOUNT (FIXED
TILT) IS A SIMPLE SOLUTION FOR
INSTALLATIONS REQUIRING MODULE TILT
BEYOND THE EXISTING ROOF SLOPE. IT
IS DESIGNED FOR TILT ANGLES FROM
0°-30° ABOVE THE HORIZONTAL
UTILIZING FIXED STANDOFF HEIGHTS
THE SNAPNRACK TILT-MOUNT IS
COMPATIBLE WITH THE VARIOUS
SNAPNRACK ROOF ATTACHMENTS
SHOWN. REFER TO SPECIFIC
"ATTACHMENT DETAIL"
REFER TO SNAPNRACK ENGINEERING
CHARTS FOR APPLICABLE RAIL SPANS.
"BIN" NUMBER ON CHART SHOULD MATCH
"BIN" NUMBER ON THIS DRAWING
REFER TO THE SNAPNRACK INSTALLATION
MANUAL FOR 5 16" Ø HARDWARE TORQUE
SPECIFICATIONS
FOR ADDITIONAL SYSTEM
REQUIREMENTS, INCLUDING MODULE
OVERHANG, SEE "SNR-DC-00329 ULTRA
RAIL, SYSTEM OVERVIEW, TYPICAL"
SNAPNRACK TILT-
MOUNT, FRONT LEG
(LENGTH VARIES)
PV MODULE, TYP.
SNAPNRACK TILT-
MOUNT, REAR LEG
(LENGTH VARIES)
TILT ABOVE
ROOF SURFACE
(5°-30°)
ROOF DECKING,
(ROOFING MATERIAL
NOT SHOWN)
FOR LEVELING REQUIREMENTS SEE
"SNR-DC-00334 ULTRA RAIL, COMPONENT
DETAIL, LEVELING SPACER ON STANDOFF"
RAILS CAN MOUNT ON ANY SIDE OF THE
STANDOFF POST
FOR "ROOF PITCH" GREATER THAN 7°,
"TILT ANGLE" MUST BE IN SAME
DIRECTION AS "ROOF PITCH"
THE SNAPNRACK OMNISHIELD CAN
BE USED TO CHEMICALLY FLASH LOW
SLOPE ROOF APPLICATIONS.
IT IS REQUIRED WHEN DECK MOUNTING
THE SNAPNRACK TILT-MOUNT KIT (FIXED TILT)
DETAIL A
OMNISHIELD
(REFER TO SNR-DC-001255)
FIXED TILT, FRONT LEG
(RAIL HIDDEN)
DETAIL B
FIXED TILT, REAR LEG
ALLOWABLE ANGLES ROOF PITCH, VARIES
INSTALLED SYSTEM
5 16"-18 BOLT WITH
SERRATED FLANGE NUT, S.S.
SNAPNRACK
STANDOFF CLAMP
SNAPNRACK STANDARD
STANDOFF, LENGTH VARIES:
5-12" OR 10"
SNAPNRACK STANDARD
STANDOFF, LENGTH VARIES:
10", 14" OR 23"
SNAPNRACK ROOF ATTACHMENT - COMPATIBLE
WITH ATTACHMENTS SHOWN ABOVE. REFER TO
SPECIFIC SNAPNRACK "ATTACHMENT DETAIL"
SNAPNRACK AP 90 L FOOT
WITH UR MOUNT HARDWARE
STRUCTURAL MEMBER,
WOOD RAFTER SHOWN
A
TILT ANGLE, RELATIVE
TO HORIZONTAL
(30° MAX)
B
SNAPNRACK TILT-
MOUNT, REAR LEG
(LENGTH VARIES)
SNAPNRACK TILT-
MOUNT, FRONT LEG
(LENGTH VARIES)
SNAPNRACK
MODULE CLAMPS
PV MODULE, TYP.
SNAPNRACK
ULTRA RAIL
A TILT-MOUNT KIT (FIXED TILT)
NTS
UR-40 RAIL | UR-45 RAIL | UR-60 RAIL
FOR USE WITH SNAPNRACK ULTRA SERIES RAILS
2 1 4"
1 1 2"
1 1 2"
1 5 8"1 3
4 "
1 1 2"
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
RACKING ATTACHMENT
DETAILS
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
S401
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#SSTAMP
WILSHIRE MINNIE
1209 E WILSHIRE AVE UNIT# MTR02
1221 E WILSHIRE AVE UNIT# MTR02
1233 E WILSHIRE AVE UNIT# MTR01
1403 S MINNIE ST UNIT# MTR01
APN: 014-251-49
DEVELOPER:
C&C DEVELOPMENT
B SLAB GROUNDING DETAIL
NTS
MIN 2"
LISTED SYSTEM GROUND
CLAMPS - SEE NEC 250.70
NOTE: 20 FEET (6 M) OR MORE OF 1/2" (13 MM)
DIAMETER REINFORCING STEEL OR #4 BARE
COPPER WIRE (OR LARGER). SEE NEC 250.52 (A)
(3). REINFORCING RODS THAT ARE COATED
WITH A NONCONDUCTIVE MATERIAL ARE NOT
ACCEPTABLE AS AN ELECTRODE.
GROUND ELECTRODE – SEE NEC
250.52 (A) (3).
CONCRETE SLAB
GRADE
GROUNDING ELECTRODE CONDUCTOR - SEE
NEC 250.62 FOR MATERIAL, NEC 250.64 FOR
INSTALLATION, AND NEC 250.66 FOR SIZE.
2" DIAMETER
STANDARD SCH40
PIPE
HOLLANDER PIPE
FLANGE WITH (4)
3/8" TITAN HD
STAINLESS STEEL
ANCHORS 2-3/4"
EMBEDMENT
1-5/8" STRUT
SOLAREDGE ENERGY BANK BAT-10K1P
1 TO 4 MOUNTED TOGETHER UTILIZING
FLOOR STAND KIT
-
C
#4 REBAR EVENLY
SPACED LESS THAN
OR EQUAL TO 12" OC
VERIFY PAD DIMENSIONS
AND THICKNESS BASED
ON SITE CONDITIONS
A SLAB ANCHORAGE DETAIL
NTS
OPTIONAL ENERGY BANK
WITH STACK KIT
WALL BRACKET
ATTACHMENT
SIDE BRACKETS
MIN 2"
MIN 4"MIN 6"
MIN 6"
MIN 36"
OTHER ELECTRICAL
EQUIPMENT
PERMITTED TO
MOUNT ON BACK OF
EQUIPMENT RACKING
FLOOR CONNECTOR
(OPTIONAL)
C HOLLAENDER BASE DETAILS
NTS
E
G
DFH
1/2 E
1/2 H
B
C
A
#48H RECTANGULAR FLOOR FLANGE
29789 = 2 HOLE SCALE: HALF
29790 = 4 HOLE
INCHES
PIPE SIZE A B C D E F G H J
2"2.40 0.56 3.50 8.00 6.00 5.50 0.81
2"2.40 0.56 3.50 8.00 6.00 6.00 4.50 0.56
JØ
DESIGN CRITERIA:
MAXIMUM WEIGHT PER VERTICAL SUPPORT: 224LBS
SEISMIC: SDS = 1.023G
SCOPE OF WORK:
1.PROVIDE A CONCRETE SLAB TO SUPPORT THE PRE-MANUFACTURED
EQUIPMENT
2.PROVIDE ANCHORAGE OF THE EQUIPMENT TO THE SLAB
MATERIALS SPECIFICATIONS:
1.ALL CONCRETE SHALL BE 2,500 PSI AT 28 DAYS. WORK CAN BEGIN 14 DAYS
AFTER PAD IS POURED
2.CONCRETE REINFORCING SHALL MEET THE TEMPERATURE AND
SHRINKAGE REQUIREMENTS OF ACI 318.
3.ALL REBAR SHALL BE #4 60 KSI STEEL ON 16"OC OR LESS CENTERED IN 6"
CONCRETE SLAB RUNNING EACH WAY WITH A MIN. 3" COVER FOR
CONCRETE FACING SOIL
4.POSTS SHALL BE 2" SCH 40 STEEL PIPES
5.1-5/8" STRUTS AND HARDWARE SHALL BE USED TO ATTACH ELECTRICAL
EQUIPMENT TO POSTS.
6.ALL HARDWARE FASTENERS AND WEDGE ANCHORS SHALL BE STAINLESS
STEEL
5.(4) 3/8" TITAN HD STAINLESS STEEL ANCHOR WITH 2-3/4" EMBEDMENT WITH
FLAT RUBBER WASHERS. A MIN. 6" DISTANCE FROM EDGE OF SLAB.
6.PATCO 585 PE DISSIMILAR METAL TAPE WHERE PIPE CONTACTS BASE
7.PADS CAN BE MOUNTED ADJACENT AND BACK-TO-BACK. 6" SPACING
BETWEEN HOLLAENDER ATTACHMENTS REQUIRED.
TYP. CONCRETE PAD SIZES
TOTAL BATERIES CONFIGURATION X Y
6 2X3 75.2 IN 58.6 IN
9 3X3 114.4 IN 58.6 IN
12 3X4 114.4 IN 72.6 IN
15 4X4*153.6 IN 72.6 IN
* ONE GROUP WILL CONTAIN 3 BATTERIES.
D BESS PAD SIZES AND EXAMPLES
NTS
72.6" (TYP)
NOTE: USE TABLES TO DETERMINE THE
DIMENSIONS OF THE PAD NEEDED. ADJACENT
GROUPS OF BATTERIES MUST MAINTAIN A MIN. 8"
SPACING.
TYP. PAD EXAMPLE
UP TO (4) SOLAREDGE ENERGY
BANKS IN GROUP
36" (TYP)
HOLLAENDER FLANGE W/ (4)
3/8" TITAN HD STAINLESS
STEEL ANCHORS 2-3/4"
EMBEDMENT MIN. 2 POSTS
PER BATTERY GROUP
SOLAREDGE ENERGY BANK, 1
TO 4 MOUNTED IN GROUP
UTILIZING FLOOR STAND KIT
TYP. PAD EXAMPLE
(15) ENERGY BANK BATTERIES.
4X4 PAD CONFIGURATION SHOWN.
Y
X
6" THICK CONCRETE
PAD
1-5/8" STRUTS AND
HARDWARE
CONCRETE PAD DIMENSIONS
TOTAL GROUPS X BATTERIES IN GROUP Y
1 36 IN 1 36 IN
2 75.2 IN 2 41.6 IN
3 114.4 IN 3 58.6 IN
4 153.6 IN 4 72.6 IN
DETAIL 1. BRACKET INSTALLATION
1.1. LEVEL THE BRACKET.
2.MARK TWO DRILLING SPOTS.
3.DRILL HOLES IN THE INSTALLATION SURFACE.
4.INSTALL THE MOUNTING BRACKET AND SECURE WITH SCREWS:
4.1.DIAMETER: 1/4"
4.2.MINIMUM EMBEDMENT: 2-1/2" (EXCLUDING TAPERED TIP)
4.3.MINIMUM FASTENER COUNT: 4
5.MOUNTING BRACKETS MUST BE PLACED ACCORDING TO MANUFACTURER GUIDELINES.
6.FASTEN BATTERY COMPONENTS TO MOUNTS PER MANUFACTURER GUIDELINES.
7.FOR EXTERIOR APPLICATIONS, M5 SEALANT SHALL BE PROVIDED AT BATTERY ANCHOR HOLES. HOLES SHALL BE FULLY CAULKED.
DETAIL 2. BATTERY INSTALLATION
WALL STUDS
16"
FOR 24" SPACING, USE
OUTER BOLT HOLES
BATTERY BRACKET
SOLARMOUNT BATTERY
BATTERY BRACKET
(2) 1/4" X 2-1/2" LAG SCREWS PER
STUD, INSTALLED AT TOP
AND BOTTOM OF BRACKET
2-1/2" MIN. EMBEDMENT INTO
STRUCTURAL MEMBER
24"
OUTER BOLT HOLE
1.SCREW IN ALL FOUR HANDLES TO THE BATTERY FRAME. MAKE SURE TO SCREW IN THE HANDLES ALL THE WAY.
2.LIFT THE BATTERY TO THE HEIGHT OF THE MOUNTING BRACKET.
3.HANG THE BATTERY ON THE MOUNTING BRACKET, WHILE HOLDING IT BY THE HANDLES.
4.SECURE WITH A MOUNTING BRACKET SCREW ON EACH SIDE. APPLY A TORQUE OF 42 in-lbs / 4.7 N*m.
5.MAINTAIN A CLEARANCE OF MIN 8" / 20 cm FROM OTHER OBJECTS.
ADDITIONAL NOTES
1.IF MOUNTING IN THE PATHWAY OF A VEHICLE, BATTERY MUST BE MOUNTED AT A LEVEL ABOVE CAR BUMPER TO AVOID ANY
POTENTIAL DAMAGE.
2.THIS DETAIL IS ONLY APPLICABLE FOR WOOD FRAMED WALL STUD SPACING FROM 12" (MIN) TO 24" (MAX) WITH WOOD 2X4 (MIN)
NOMINAL WALL FRAMING MEMBERS.
3.ALL WALL FRAMING REFERENCED IN THE DETAILS SHALL BE SHEATHED ON A MINIMUM OF ONE SIDE AND SHALL BE PART OF
THE STRUCTURE'S MAIN PERMITTED BEARING WALL AND OR LATERAL RESISTING SYSTEM.
E WALL MOUNT DETAIL
NTS
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
EQUIPMENT PAD
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
S500
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#SSTAMP
WILSHIRE MINNIE
1209 3/4 E WILSHIRE AVE UNIT# ELE01
1221 3/4 E WILSHIRE AVE UNIT# ELE01
1229 3/4 E WILSHIRE AVE UNIT# ELE01
1233 E WILSHIRE AVE UNIT# MTR01
1401 S MINNIE ST UNIT# MTR01
1403 S MINNIE ST UNIT# MTR01
1425 S MINNIE ST UNIT# MTR01
APN: 014-251-49 / 014-251-50
DEVELOPER:
C&C DEVELOPMENT
POINT OF INTERCONNECTION
SEE WARNING LABEL DETAIL 1/E700
PV AC DISCONNECT
SEE WARNING LABEL DETAIL 2/E700
AC DISCO #
LOAD CENTER
SEE WARNING LABEL DETAIL 6 & 7/E700
LOAD CENTER #
XX
PV INVERTER AND DC DISCONNECT
SWITCH
SEE WARNING LABEL DETAIL 3 & 9/E700
INVERTER # XX
H
(N) SOLAR CANOPY
STRUCTURAL COLUMN
DOWN SLOPE
(E) POLE-MOUNTED LIGHT
FIXTURE
(E) FIRE HYDRANT
ELECTRICAL EQUIPMENT
LEGEND
MAIN PANEL & SUB
PANELS
INVERTER(S) WITH
INTEGRATED DC
DISCONNECT AND AFCI
GENERAL LOCATION OF EQUIPMENT
ATTIC VENT
FLUSH ATTIC VENT
PVC PIPE VENT
SATELLITE DISH
T-VENT
FIRE SETBACKS
METAL PIPE VENT
HARDSCAPE
PROPERTY LINEPL
PITCH
2°
POI #
X
XX
SECTION CUT
SHEET NUMBER
XX
X
DETAIL CUT
SHEET NUMBER
RAIL
STANDOFFS &
FOOTINGS
SOLAR MODULES
METER SOCKET & DISCONNECTS
PV LOAD CENTER
POI BOUNDARY
AC-X.X
LC-X.X
INV-X.X
POI-X
XX##
TL: ##° AZ: ###°
ROOF IDENTIFIER
MOUNTING INDEX
MOUNTING TYPE
TILT
AZUMUTH
CHIMNEY
ELECTRICAL CONDUIT
POI
TRENCHING
℄
TESLA BACKUP GATEWAY 2
(IF APPLICABLE)
TESLA PAOWERWALL 2
WALL OR PAD MOUNTED
(IF APPLICABLE)
SOLAREDGE ENERGY BANK
WALL OR PAD MOUNTED
(IF APPLICABLE)
PL
PL PL PL PL PL
PL
PL
PL
PL
PL
PL PL
PL
PL
PL
PL
PL
PL
PL
PLPLPLPLPLPLPLPLPL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL PL
1209 E WILSHIRE AVE 1213 E WILSHIRE AVE
1221 E WILSHIRE AVE
1225 E WILSHIRE AVE
1229 E WILSHIRE AVE
1233 E WILSHIRE AVE
1401 S MINNIE ST
1409 S MINNIE ST
1413 S MINNIE ST
1421 S MINNIE ST
1235 E WILSHIRE AVE
POI
POI
PO
I
POI
PO
I
POI
POI
POI
PO
I
POI
POI
(N) CONDUIT RUN
(ENTRENCHED ~ 30 FT)
(N) CONDUIT RUN
(ENTRENCHED ~ 10 FT)
(N) CONDUIT RUN
(ENTRENCHED ~ 20 FT)
(N) CONDUIT RUN
(ENTRENCHED ~ 6 FT)
(N) CONDUIT RUN
(ENTRENCHED ~ 10 FT)
1425 S MINNIE ST
1429 S MINNIE ST
S
S
T
A
N
D
A
R
D
A
V
E
MI
N
N
I
E
S
T
E WILSHIRE AVE
(N) CONDUIT RUN
(ENTRENCHED ~ 13 FT)
(N) CONDUIT RUN
(ENTRENCHED ~ 10 FT)
LC-7.1
INV-7.1
INV-7.2
BES-7.1-7.6
RB03
TL: 5° AZ: 270°
RB04
TL: 5° AZ: 90°
RB05
TL: 5° AZ: 270°
RB06
TL: 5° AZ: 90°
RB07
TL: 5° AZ: 270°
RB08
TL: 5° AZ: 90°
RB09
TL: 5° AZ: 322°
RB10
TL: 5° AZ: 142°
RB11
TL: 5° AZ: 180°
RB12
TL: 5° AZ: 180°
RB13
TL: 5° AZ: 270°
RB14
TL: 5° AZ: 90°
RF01
TL: 10° AZ: 270°
RF02
TL: 10° AZ: 90°
RF03
TL: 10° AZ: 270°
RF04
TL: 10° AZ: 90°
RF05
TL: 19° AZ: 270°
RF06
TL: 19° AZ: 90°
RF07
TL: 15° AZ: 0°
RF08
TL: 15° AZ: 270°
RF09
TL: 15° AZ: 180°
RF10
TL: 15° AZ: 90°
RF11
TL: 10° AZ: 0°
RF12
TL: 10° AZ: 180°
RF13
TL: 10° AZ: 270°
RF14
TL: 10° AZ: 90°
POI-1
AC-1.1
AC-1.2
LC-1.1
INV-1.1 INV-1.2
INV-1.3
INV-1.4
BES-1.1-1.12
POI-2
AC-2.1
AC-2.2
LC-2.1 INV-2.1
INV-2.2
INV-2.3
BES-2.1-2.9 POI-3
AC-3.1
AC-3.2
LC-3.1 INV-3.1
INV-3.2
INV-3.3
BES-3.1-3.9
BES-5.1-5.6
POI-6
AC-6.1
AC-6.2
POI-4
AC-4.1
AC-4.2
LC-4.1
INV-4.1
INV-4.2
BES-4.1-4.6
E200
E
E200
F
E200
G
E201
B
E201
C
E201
D
E201
D
E300
A
E301
A
E301
B
E302
A
E302
B
E303
B
LC-6.1
INV-6.1
INV-6.2
BES-6.1-6.6
E201
C
E303
A
1433 S MINNIE ST
1437 S MINNIE ST
FIRE SETBACKS (3' TYP)
ROOF PATHWAY (3' TYP)
4' PERIMETER
SETBACKS
ROOF PATHWAY (3' TYP)
FIRE SETBACKS (3' TYP)
APN #: 014-251-50
APN #: 014-251-49
1439 S MINNIE ST
1201 E WILSHIRE AVE
RB01
TL: 5° AZ: 270°
RB02
TL: 5° AZ: 90°
4' PERIMETER
SETBACKS
POI-5
AC-5.1
AC-5.2
LC-5.1
INV-5.1
INV-5.2
INV-5.3
E201
A
1403
S MINNIE ST
1229 3/4 E WILSHIRE
AVE UNIT# ELE01
1221 3/4 E WILSHIRE
AVE UNIT# ELE01
1209 3/4 E WILSHIRE
AVE UNIT# ELE01
(N) SCE PV PRODUCTION METER
REF MTR #: 222012-828414
ADDR: 1229 E WILSHIRE AVE UNIT#
MTR02
(N) SCE PV PRODUCTION METER
REF MTR #: 222013-142908
ADDR: 1233 E WILSHIRE AVE UNIT#
MTR01
(N) SCE PV PRODUCTION METER
REF MTR #: 222013-048110
ADDR: 1403 S MINNIE ST UNIT# MTR01
(N) SCE PV PRODUCTION METER
REF MTR #: 222012-828760
ADDR: 1209 E WILSHIRE AVE UNIT#
MTR02
(N) SCE PV PRODUCTION METER
REF MTR #: 222010-847068
ADDR: 1221 E WILSHIRE AVE UNIT#
MTR02
(N) SCE PV PRODUCTION METER
REF MTR #: 222012-825599
ADDR: 1401 S MINNIE ST UNIT# MTR01
POI-7
AC-7.1
AC-7.2
(N) SCE PV PRODUCTION METER
REF MTR #: 222013-124043
ADDR: 1425 S MINNIE ST UNIT# MTR01
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
ELECTRICAL SITE PLAN
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
E100
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#ESTAMP
SCALE: 1" = 40'
1.PV LAYOUT ADHERES TO CFC 2022
SECTION 1205.2.1.1 THRU 1205.2.1.3.
2.PER SECTION 1205.3 EXCEPTION,
ROOF CONFIGURATION IS SIMILAR TO
THAT OF A GROUP R-3 OCCUPANCY.
ROOF PITCH EXCEEDS 2:12.
3.REQUIREMENTS OBSERVED TO
PROVIDE ROOF ACCESS, PROVIDE
SMOKE VENTILATION
OPPORTUNITIES, PROVIDE
EMERGENCY EGRESS FROM THE
ROOF.
ACCESS NOTES
SITE PLAN KEY
E101
E102
IFC SECTION 1205.2 ACCESS
PATHWAYS
BLDG
NUMBER
PLAN VIEW
AREA (sqft)
MODULE
COUNT
COVERAGE
(%)
1225 3023.5 74 53.2%
1229 3036.7 72 51.5%
1235 2045.1 42 44.6%
1401 4332.9 87 43.6%
1425 3711.3 57 33.4%
Totals 16150 332
(N) CONCRETE PAD
SEE S500
(N) DC DISCONNECT WILSHIRE MINNIE
1209 E WILSHIRE AVE UNIT# MTR02
1209 3/4 E WILSHIRE AVE UNIT# ELE01
1221 E WILSHIRE AVE UNIT# MTR02
1221 3/4 E WILSHIRE AVE UNIT# ELE01
1229 E WILSHIRE AVE UNIT# MTR02
1229 3/4 E WILSHIRE AVE UNIT# ELE01
1233 E WILSHIRE AVE UNIT# MTR01
1401 S MINNIE ST UNIT# MTR01
1403 S MINNIE ST UNIT# MTR01
1425 S MINNIE ST UNIT# MTR01
APN: 014-251-49 / 014-251-50
DEVELOPER: C&C DEVELOPMENT
(N) DC DISCONNECT
(N) DC DISCONNECT
(N) DC
DISCONNECT
POINT OF INTERCONNECTION
SEE WARNING LABEL DETAIL 1/E700
PV AC DISCONNECT
SEE WARNING LABEL DETAIL 2/E700
AC DISCO #
LOAD CENTER
SEE WARNING LABEL DETAIL 6 & 7/E700
LOAD CENTER #
XX
PV INVERTER AND DC DISCONNECT
SWITCH
SEE WARNING LABEL DETAIL 3 & 9/E700
INVERTER # XX
H
(N) SOLAR CANOPY
STRUCTURAL COLUMN
DOWN SLOPE
(E) POLE-MOUNTED LIGHT
FIXTURE
(E) FIRE HYDRANT
ELECTRICAL EQUIPMENT
LEGEND
MAIN PANEL & SUB
PANELS
INVERTER(S) WITH
INTEGRATED DC
DISCONNECT AND AFCI
GENERAL LOCATION OF EQUIPMENT
ATTIC VENT
FLUSH ATTIC VENT
PVC PIPE VENT
SATELLITE DISH
T-VENT
FIRE SETBACKS
METAL PIPE VENT
HARDSCAPE
PROPERTY LINEPL
PITCH
2°
POI #
X
XX
SECTION CUT
SHEET NUMBER
XX
X
DETAIL CUT
SHEET NUMBER
RAIL
STANDOFFS &
FOOTINGS
SOLAR MODULES
METER SOCKET & DISCONNECTS
PV LOAD CENTER
POI BOUNDARY
AC-X.X
LC-X.X
INV-X.X
POI-X
XX##
TL: ##° AZ: ###°
ROOF IDENTIFIER
MOUNTING INDEX
MOUNTING TYPE
TILT
AZUMUTH
CHIMNEY
ELECTRICAL CONDUIT
POI
TRENCHING
℄
TESLA BACKUP GATEWAY 2
(IF APPLICABLE)
TESLA PAOWERWALL 2
WALL OR PAD MOUNTED
(IF APPLICABLE)
SOLAREDGE ENERGY BANK
WALL OR PAD MOUNTED
(IF APPLICABLE)
1209 E WILSHIRE AVE
1213 E WILSHIRE AVE
1221 E WILSHIRE AVE
1225 E WILSHIRE AVE
1229 E WILSHIRE AVE
1233 E WILSHIRE AVE
1401 S MINNIE ST
1235 E WILSHIRE AVEPO
I
POIPOIPOI
PO
I
POI POI POI
PO
I
PO
I
POIPOI
PO
I
PO
I
POI POI
POI
POIPOI
POI POI
PO
I
PO
I
POI
POI
PO
I
POI
POI
POI
POI
PO
I
POI
POI
(N) CONDUIT RUN
(ENTRENCHED ~ 30 FT)
(N) CONDUIT RUN
(ENTRENCHED ~ 10 FT)
(N) CONDUIT RUN
(ENTRENCHED ~ 20 FT)
(N) CONDUIT RUN
(ENTRENCHED ~ 6 FT)
(N) CONDUIT RUN
(ENTRENCHED ~ 10 FT)
E WILSHIRE AVE
(N) CONDUIT RUN
(ENTRENCHED ~ 13 FT)
(N) CONDUIT RUN
(ENTRENCHED ~ 10 FT)
RB03
TL: 5° AZ: 270°
RB04
TL: 5° AZ: 90°
RB05
TL: 5° AZ: 270°
RB06
TL: 5° AZ: 90°
RB07
TL: 5° AZ: 270°
RB08
TL: 5° AZ: 90°
RB09
TL: 5° AZ: 322°
RB10
TL: 5° AZ: 142°
RF01
TL: 10° AZ: 270°
RF02
TL: 10° AZ: 90°
RF03
TL: 10° AZ: 270°
RF04
TL: 10° AZ: 90°
RF05
TL: 19° AZ: 270°
RF06
TL: 19° AZ: 90°
RF07
TL: 15° AZ: 0°
RF08
TL: 15° AZ: 270°
RF09
TL: 15° AZ: 180°
RF10
TL: 15° AZ: 90°
POI-1
AC-1.1
AC-1.2
LC-1.1
INV-1.1 INV-1.2
INV-1.3
INV-1.4
BES-1.1-1.12
POI-2
AC-2.1
AC-2.2
LC-2.1 INV-2.1
INV-2.2
INV-2.3
BES-2.1-2.9 POI-3
AC-3.1
AC-3.2
LC-3.1 INV-3.1
INV-3.2
INV-3.3
BES-3.1-3.9
BES-5.1-5.6
POI-4
AC-4.1
AC-4.2
LC-4.1
INV-4.1
INV-4.2
BES-4.1-4.6
E200
E
E200
F
E200
G
E201
B
E300
A
E301
A
E301
B
E302
A
E302
B
FIRE SETBACKS (3' TYP)
ROOF PATHWAY (3' TYP)
APN #: 014-251-49
1201 E WILSHIRE AVE
RB01
TL: 5° AZ: 270°
RB02
TL: 5° AZ: 90°
4' PERIMETER
SETBACKS
POI-5
AC-5.1
AC-5.2
LC-5.1
INV-5.1
INV-5.2
INV-5.3
E201
A
1229 3/4 E WILSHIRE
AVE UNIT# ELE01
1221 3/4 E WILSHIRE
AVE UNIT# ELE01
1209 3/4 E WILSHIRE
AVE UNIT# ELE01
(N) SCE PV PRODUCTION METER
REF MTR #: 222012-828414
ADDR: 1229 E WILSHIRE AVE UNIT#
MTR02
(N) SCE PV PRODUCTION METER
REF MTR #: 222013-142908
ADDR: 1233 E WILSHIRE AVE UNIT#
MTR01
(N) SCE PV PRODUCTION METER
REF MTR #: 222012-828760
ADDR: 1209 E WILSHIRE AVE UNIT#
MTR02
(N) SCE PV PRODUCTION METER
REF MTR #: 222010-847068
ADDR: 1221 E WILSHIRE AVE UNIT#
MTR02
(N) SCE PV PRODUCTION METER
REF MTR #: 222012-825599
ADDR: 1401 S MINNIE ST UNIT# MTR01
PL
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
ELECTRICAL SITE PLAN
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
E101
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#ESTAMP
SITE PLAN KEY
E101
E102
POI-1 ROOF SCHEDULE
ADDRESS LABEL RACKING TILT (DEG)AZIMUTH
(DEG)
BUILDING
HEIGHT (FT)
MODULE
COUNT
MODULE AREA (SQFT)KW DC
1201 RB01 FIXED TILT 5°270°20 20 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]422.4 8.20
1201 RB02 FIXED TILT 5°90°20 28 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]591.4 11.48
1209 RB03 FIXED TILT 5°270°20 21 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]443.5 8.61
1209 RB04 FIXED TILT 5°90°20 21 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]443.5 8.61
1213 RB05 FIXED TILT 5°270°20 17 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]359.1 6.97
1213 RB06 FIXED TILT 5°90°20 25 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]528.0 10.25
Totals 132 2788 54
POI-2 ROOF SCHEDULE
ADDRESS LABEL RACKING TILT (DEG)AZIMUTH
(DEG)
BUILDING
HEIGHT (FT)
MODULE
COUNT
MODULE AREA (SQFT)KW DC
1221 RB07 FIXED TILT 5°270°20 25 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]528.0 10.25
1221 RB08 FIXED TILT 5°90°20 17 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]359.1 6.97
1225 RF01 FLUSH MOUNT 10°270°20 32 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]675.9 13.12
1225 RF02 FLUSH MOUNT 10°90°20 42 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]887.1 17.22
Totals 116 2450 48
POI-3 ROOF SCHEDULE
ADDRESS LABEL RACKING TILT (DEG)AZIMUTH
(DEG)
BUILDING
HEIGHT (FT)
MODULE
COUNT
MODULE AREA (SQFT)KW DC
1229 RF03 FLUSH MOUNT 10°270°20 40 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]844.8 16.40
1229 RF04 FLUSH MOUNT 10°90°20 32 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]675.9 13.12
1235 RF05 FLUSH MOUNT 19°270°20 20 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]422.4 8.20
1235 RF06 FLUSH MOUNT 19°90°20 22 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]464.7 9.02
Totals 114 2408 47
POI-4 ROOF SCHEDULE
ADDRESS LABEL RACKING TILT (DEG)AZIMUTH
(DEG)
BUILDING
HEIGHT (FT)
MODULE
COUNT
MODULE AREA (SQFT)KW DC
1233 RB09 FIXED TILT 5°322°20 44 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]929.3 18.04
1233 RB10 FIXED TILT 5°142°20 26 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]549.1 10.66
Totals 70 1478 29
POI-5 ROOF SCHEDULE
ADDRESS LABEL RACKING TILT (DEG)AZIMUTH
(DEG)
BUILDING
HEIGHT (FT)
MODULE
COUNT
MODULE AREA (SQFT)KW DC
1401 RF07 FLUSH MOUNT 15°0°20 39 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]823.7 15.99
1401 RF08 FLUSH MOUNT 15°270°20 5 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]105.6 2.05
1401 RF09 FLUSH MOUNT 15°180°20 39 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]823.7 15.99
1401 RF10 FLUSH MOUNT 15°90°20 4 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]84.5 1.64
Totals 87 1838 36
SCALE: 1" = 20'
(N) DC
DISCONNECT
(N) DC
DISCONNECT
(N) DC
DISCONNECT
(N) DC
DISCONNECT
(N) DC
DISCONNECT
(N) DC
DISCONNECT
(N) DC
DISCONNECT
(N) DC
DISCONNECT
(N) CONCRETE PAD
SEE S500
WILSHIRE MINNIE
1209 E WILSHIRE AVE UNIT# MTR02
1209 3/4 E WILSHIRE AVE UNIT# ELE01
1221 E WILSHIRE AVE UNIT# MTR02
1221 3/4 E WILSHIRE AVE UNIT# ELE01
1229 E WILSHIRE AVE UNIT# MTR02
1229 3/4 E WILSHIRE AVE UNIT# ELE01
1233 E WILSHIRE AVE UNIT# MTR01
1401 S MINNIE ST UNIT# MTR01
APN: 014-251-49
DEVELOPER: C&C DEVELOPMENT
POINT OF INTERCONNECTION
SEE WARNING LABEL DETAIL 1/E700
PV AC DISCONNECT
SEE WARNING LABEL DETAIL 2/E700
AC DISCO #
LOAD CENTER
SEE WARNING LABEL DETAIL 6 & 7/E700
LOAD CENTER #
XX
PV INVERTER AND DC DISCONNECT
SWITCH
SEE WARNING LABEL DETAIL 3 & 9/E700
INVERTER # XX
H
(N) SOLAR CANOPY
STRUCTURAL COLUMN
DOWN SLOPE
(E) POLE-MOUNTED LIGHT
FIXTURE
(E) FIRE HYDRANT
ELECTRICAL EQUIPMENT
LEGEND
MAIN PANEL & SUB
PANELS
INVERTER(S) WITH
INTEGRATED DC
DISCONNECT AND AFCI
GENERAL LOCATION OF EQUIPMENT
ATTIC VENT
FLUSH ATTIC VENT
PVC PIPE VENT
SATELLITE DISH
T-VENT
FIRE SETBACKS
METAL PIPE VENT
HARDSCAPE
PROPERTY LINEPL
PITCH
2°
POI #
X
XX
SECTION CUT
SHEET NUMBER
XX
X
DETAIL CUT
SHEET NUMBER
RAIL
STANDOFFS &
FOOTINGS
SOLAR MODULES
METER SOCKET & DISCONNECTS
PV LOAD CENTER
POI BOUNDARY
AC-X.X
LC-X.X
INV-X.X
POI-X
XX##
TL: ##° AZ: ###°
ROOF IDENTIFIER
MOUNTING INDEX
MOUNTING TYPE
TILT
AZUMUTH
CHIMNEY
ELECTRICAL CONDUIT
POI
TRENCHING
℄
TESLA BACKUP GATEWAY 2
(IF APPLICABLE)
TESLA PAOWERWALL 2
WALL OR PAD MOUNTED
(IF APPLICABLE)
SOLAREDGE ENERGY BANK
WALL OR PAD MOUNTED
(IF APPLICABLE)
1409 S MINNIE ST
1413 S MINNIE ST
1421 S MINNIE ST
PO
I
POI
POI
PO
I
POIPOI
POIPOIPOI
PO
I
POI
POI
PO
I
POI POI
1425 S MINNIE ST LC-7.1
INV-7.1
INV-7.2
BES-7.1-7.6
RB11
TL: 5° AZ: 180°
RB12
TL: 5° AZ: 180°
RB13
TL: 5° AZ: 270°
RB14
TL: 5° AZ: 90°
TL: 15° AZ: 180°
RF11
TL: 10° AZ: 0°
RF12
TL: 10° AZ: 180°
RF13
TL: 10° AZ: 270°
RF14
TL: 10° AZ: 90°
POI-6
AC-6.1
AC-6.2
E201
C
E201
D
E201
D
E303
B
LC-6.1
INV-6.1
INV-6.2
BES-6.1-6.6
E201
C
E303
A
4' PERIMETER
SETBACKS
ROOF PATHWAY (3' TYP)
FIRE SETBACKS (3' TYP)
1403
S MINNIE ST
(N) SCE PV PRODUCTION METER
REF MTR #: 222013-048110
ADDR: 1403 S MINNIE ST UNIT# MTR01
POI-7
AC-7.1
AC-7.2
(N) SCE PV PRODUCTION METER
REF MTR #: 222013-124043
ADDR: 1425 S MINNIE ST UNIT# MTR01
PL
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
ELECTRICAL SITE PLAN
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
E102
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#ESTAMP
SCALE: 1/16" = 1'-0"
SITE PLAN KEY
E101
E102
POI-6 ROOF SCHEDULE
ADDRESS LABEL RACKING TILT (DEG)AZIMUTH
(DEG)
BUILDING
HEIGHT (FT)
MODULE
COUNT
MODULE AREA (SQFT)KW DC
1403 RB11 FIXED TILT 5°180°20 18 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]380.2 7.38
1403 RB12 FIXED TILT 5°180°20 15 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]316.8 6.15
1403 RB13 FIXED TILT 5°270°20 6 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]126.7 2.46
1403 RB14 FIXED TILT 5°90°20 17 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]359.1 6.97
Totals 56 1183 23
POI-7 ROOF SCHEDULE
ADDRESS LABEL RACKING TILT (DEG)AZIMUTH
(DEG)
BUILDING
HEIGHT (FT)
MODULE
COUNT
MODULE AREA (SQFT)KW DC
1425 RF11 FLUSH MOUNT 10°0°20 16 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]337.9 6.56
1425 RF12 FLUSH MOUNT 10°180°20 23 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]485.8 9.43
1425 RF13 FLUSH MOUNT 10°270°20 8 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]169.0 3.28
1425 RF14 FLUSH MOUNT 10°90°20 10 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]211.2 4.10
Totals 57 1204 23
WILSHIRE MINNIE
1403 S MINNIE ST UNIT# MTR01
1425 S MINNIE ST UNIT# MTR01
APN: 014-251-49 / 014-251-50
DEVELOPER:
C&C DEVELOPMENT
FLOOR STAND KIT
16" MIN.
CLEAR
3'
8"
11'-5"
11"11"
16" MIN.
CLEAR
11"
4'-6"
FLOOR STAND KIT
3'
8"
11'-5"
16" MIN.
CLEAR
11"
4'-6"
FLOOR STAND KIT
3'8"
11'-5"
16" MIN.
CLEAR
11"
4'-6"
11"
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
ELECTRICAL PLAN VIEWS
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
E200
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#ESTAMP
(N) PV POINT OF INTERCONNECTION (POI-1)
(N) PV PRODUCTION METER SOCKET
1209 E WILSHIRE AVE UNIT# MTR02 PV PRODUCTION
METER
REFERENCE METER NUMBER: 222012-828760
(N) UTILITY AC DISCONNECT
(ACDS-1.1)
(N) MAINTENANCE AC DISCONNECT (ACDS-1.2)
(N) AC LOAD
CENTER (LC-1.1)
(N) PV INVERTER WITH PV+ESS
DC DISCONNECT (INV-1.4)
(N) PV INVERTER WITH PV+ESS
DC DISCONNECT (INV-1.1)
(N) PV INVERTER WITH PV+ESS
DC DISCONNECT (INV-1.2)
(N) PV INVERTER WITH PV+ESS
DC DISCONNECT (INV-1.3)(N) 77.6 kWh ESS GROUP OF
(8) SOLAREDGE BAT-10K1P BATTERIES
(FLOOR MOUNTED)
A EQUIPMENT PLAN - POI-1 - 1209 E WILSHIRE AVE
SCALE: 3/16" = 1'-0"
(N) PV POINT OF INTERCONNECTION (POI-2)
(N) PV PRODUCTION METER SOCKET 1221 E
WILSHIRE AVE UNIT# MTR02 PV PRODUCTION
METER
REFERENCE METER NUMBER: 222010-847068
(N) UTILITY AC DISCONNECT (ACDS-2.1)
(N) MAINTENANCE AC DISCONNECT (ACDS-2.2)
(N) AC LOAD
CENTER (LC-2.1)
(N) PV INVERTER WITH PV+ESS
DC DISCONNECT (INV-2.3)
(N) PV INVERTER WITH PV+ESS
DC DISCONNECT (INV-2.2)
(N) PV INVERTER WITH PV+ESS
DC DISCONNECT (INV-2.1)
C EQUIPMENT PLAN - POI-2 - 1221 E WILSHIRE AVE
SCALE: 3/16" = 1'-0"
(N) PV POINT OF INTERCONNECTION (POI-3)
(N) PV PRODUCTION METER SOCKET 1229 E
WILSHIRE AVE UNIT# MTR02 PV PRODUCTION
METER
REFERENCE METER NUMBER: 222012-828414
(N) UTILITY AC DISCONNECT (ACDS-3.1)
(N) MAINTENANCE AC DISCONNECT (ACDS-3.2)
(N) AC LOAD
CENTER (LC-3.1)
(N) PV INVERTER WITH PV+ESS
DC DISCONNECT (INV-3.1)
(N) PV INVERTER WITH PV+ESS
DC DISCONNECT (INV-3.3)
(N) PV INVERTER WITH PV+ESS
DC DISCONNECT (INV-3.2)
E EQUIPMENT PLAN - POI-3 - 1229 E WILSHIRE AVE
SCALE: 3/16" = 1'-0"
B ESS ELEVATION - POI-1 - 1209 E WILSHIRE AVE
SCALE: 1/2" = 1'-0"
1201 E WILSHIRE 1209 E WILSHIRE
1209 3/4 E WILSHIRE
AVE UNIT# ELE01
(N) 38.8 kWh ESS GROUP OF
(4) SOLAREDGE BAT-10K1P BATTERIES
(FLOOR MOUNTED)(EACH BATTERY 9.7KWh)
1207.5.1 &
UL 9540A TEST
1207.8.3
(N) 77.6 kWh ESS GROUP OF
(8) SOLAREDGE BAT-10K1P BATTERIES
(FLOOR MOUNTED)
(N) 38.8 kWh ESS GROUP OF
(4) SOLAREDGE BAT-10K1P BATTERIES
(FLOOR MOUNTED)
1209 3/4 E WILSHIRE
AVE UNIT# ELE01 (N) PV INVERTER WITH PV+ESS
DC DISCONNECT (INV-1.4)
(N) PV INVERTERWITH PV+ESS
DC DISCONNECT (INV-1.1)
(N) PV INVERTER WITH PV+ESS
DC DISCONNECT (INV-1.2)
(N) PV INVERTER WITH PV+ESS
DC DISCONNECT (INV-1.3)
1213 E WILSHIRE 1221 E WILSHIRE
1221 3/4 E WILSHIRE
AVE UNIT# ELE01
1207.5.1 &
UL 9540A TEST
1207.8.3
(N) 58.2 kWh ESS GROUP OF
(6) SOLAREDGE BAT-10K1P BATTERIES
(FLOOR MOUNTED)(EACH BATTERY 9.7KWh)
(N) 29.1 kWh ESS GROUP OF
(3) SOLAREDGE BAT-10K1P BATTERIES
(FLOOR MOUNTED)(EACH BATTERY 9.7KWh)
D ESS ELEVATION - POI-2 - 1221 E WILSHIRE AVE
SCALE: 1/2" = 1'-0"
1221 3/4 E WILSHIRE
AVE UNIT# ELE01
(N) PV INVERTER WITH PV+ESS
DC DISCONNECT (INV-2.3)
(N) PV INVERTER WITH PV+ESS
DC DISCONNECT (INV-2.2)
(N) PV INVERTER WITH PV+ESS
DC DISCONNECT (INV-2.1)
(N) 58.2 kWh ESS GROUP OF
(6) SOLAREDGE BAT-10K1P BATTERIES
(FLOOR MOUNTED)
(N) 29.1 kWh ESS GROUP OF
(3) SOLAREDGE BAT-10K1P BATTERIES
(FLOOR MOUNTED)
1207.5.1 &
UL 9540A TEST
1207.8.3
1225 E WILSHIRE 1229 E WILSHIRE
(N) 58.2 kWh ESS GROUP OF
(6) SOLAREDGE BAT-10K1P BATTERIES
(FLOOR MOUNTED)(EACH BATTERY 9.7KWh)
(N) 29.1 kWh ESS GROUP OF
(3) SOLAREDGE BAT-10K1P BATTERIES
(FLOOR MOUNTED)(EACH BATTERY 9.7KWh)
F ESS ELEVATION - POI-3 - 1229 E WILSHIRE AVE
SCALE: 1/2" = 1'-0"
1229 3/4 E WILSHIRE
AVE UNIT# ELE01
(N) 58.2 kWh ESS GROUP OF
(6) SOLAREDGE BAT-10K1P BATTERIES
(FLOOR MOUNTED)
(N) 29.1 kWh ESS GROUP OF
(3) SOLAREDGE BAT-10K1P BATTERIES
(FLOOR MOUNTED)
1229 3/4 E WILSHIRE
AVE UNIT# ELE01
(N) PV INVERTER WITH PV+ESS
DC DISCONNECT (INV-3.1)
(N) PV INVERTER WITH PV+ESS
DC DISCONNECT (INV-3.3)
(N) PV INVERTER WITH PV+ESS
DC DISCONNECT (INV-3.2)
(N) DC
DISCONNECTS
(N) DC
DISCONNECT
(N) DC
DISCONNECT
(N) DC
DISCONNECT
1207.4.2 &
110.26(A)(1)
WORKING CLEARANCE
1207.4.2 &
110.26(A)(1)
WORKING CLEARANCE
1207.4.2 &
110.26(A)(1)
WORKING CLEARANCE
WILSHIRE MINNIE
1209 E WILSHIRE AVE UNIT# MTR02
1209 3/4 E WILSHIRE AVE UNIT# ELE01
1221 E WILSHIRE AVE UNIT# MTR02
1221 3/4 E WILSHIRE AVE UNIT# ELE01
1229 E WILSHIRE AVE UNIT# MTR02
1229 3/4 E WILSHIRE AVE UNIT# ELE01
APN: 014-251-49
DEVELOPER:
C&C DEVELOPMENT
3'4'
-
5
"
3'3'
-
3
"
3'
-
3
"
3'
6'
-
7
"
10
'
-
5
"
10'10'
10'17'-11
"
22'-9"
11
'
-
6
"
8"8"
8"
8"8"8"
8"8"8"
13
'
PL
PL
PL
PL
PL
PL
PL
PL
PL
PL
8"8"1'-8"
8"8"
8"8"8"
4"
1'1'
4"
1'1'1'
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
ELECTRICAL PLAN VIEWS
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
E201
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#ESTAMP
(N) PV POINT OF INTERCONNECTION (POI-4)
(N) PV PRODUCTION METER SOCKET 1233 E WILSHIRE AVE UNIT# MTR01 PV PRODUCTION METER
REFERENCE METER NUMBER: 222013-142908
(N) UTILITY AC DISCONNECT (ACDS-4.1)
(N) MAINTENANCE AC DISCONNECT (ACDS-4.2)
(N) AC LOAD CENTER (LC-4.1) (ON BATTERY PAD)
(N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-4.1) (ON BATTERY PAD)
(N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-4.2) (ON BATTERY PAD)
(N) 58.2 kWh ESS GROUP OF (6) SOLAREDGE BAT-10K1P BATTERIES
(ON BATTERY PAD SEE S500)
(EACH BATTERY 9.7KWh)
A EQUIPMENT PLAN - POI-4 1233 E WILSHIRE AVE
SCALE: 1/4"=1'-0"
(N) PV POINT OF INTERCONNECTION (POI-5)
(N) PV PRODUCTION METER SOCKET 1401 S MINNIE ST UNIT# MTR01 PV PRODUCTION METER
REFERENCE METER NUMBER: 222012-825599
(N) UTILITY AC DISCONNECT (ACDS-5.1)
(N) MAINTENANCE AC DISCONNECT (ACDS-5.2)
(N) AC LOAD CENTER (LC-5.1)
(N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-5.1)
(N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-5.2)
(N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-5.3)
(N) 58.2 kWh ESS GROUP OF (6) SOLAREDGE BAT-10K1P BATTERIES WALL
MOUNTED(EACH BATTERY 9.7KWh)
B EQUIPMENT PLAN - POI-5 1401 MINNIE ST
SCALE: 1/8" = 1'-0"
(N) PV POINT OF INTERCONNECTION (POI-6)
(N) PV PRODUCTION METER SOCKET 1403 S
MINNIE ST UNIT# MTR01 PV PRODUCTION METER
REFERENCE METER NUMBER: 222013-048110
(N) UTILITY AC DISCONNECT (ACDS-6.1)
(N) MAINTENANCE AC DISCONNECT (ACDS-6.2)
D EQUIPMENT PLAN - POI-6 1403 MINNIE ST
SCALE: 1/8" = 1'-0"
(N) AC LOAD CENTER (LC-6.1)
(N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-6.2)
(N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-6.1)
GARBAGE BIN
4'-6
"
10'
17'
30'-2"
1207.8.3
1207.4.2 &
110.26(A)(1)
1233 E WILSHIRE
1207.8.3
1207.8.3
1207.4.2 &
110.26(A)(1) WORKING CLEARANCE
(E) FENCE
(N) TYP. IMPACT PROTECTION BOLLARDS
1207.4.5 & 312.2
1207.8.3
1401 MINNIE ST
C ESS ELEVATION - POI-5 1401 MINNIE ST
SCALE: 3/4" = 1'-0"
3'
5'-
4
"
3'-2"
13'-9"
1401 MINNIE ST
(E) WINDOW
(E) WINDOW
1207.8.4 & UL 9540A REPORT
(N) 58.2 kWh ESS GROUP OF (6) SOLAREDGE BAT-10K1P BATTERIES WALL MOUNTED
(N) 58.2 kWh ESS GROUP OF
(6) SOLAREDGE BAT-10K1P BATTERIES WALL MOUNTED
(EACH BATTERY 9.7KWh)
1403 MINNIE ST
1409 MINNIE ST
1207.8.3
1207.4.2 & 110.26(A)(1) WORKING CLEARANCE E ESS ELEVATION - POI-6 1403 MINNIE ST
SCALE: 3/8" = 1'-0"
(N) AC LOAD CENTER (LC-6.1)
(N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-6.2)
(N) PV INVERTER WITH PV+ESS DC DISCONNECT (INV-6.1)
37'
3'-8"12'-10"
(N) 58.2 kWh ESS GROUP OF
(6) SOLAREDGE BAT-10K1P BATTERIES WALL MOUNTED
1403 MINNIE ST
(N) DC DISCONNECT
8'
-
9
"
DISTANCE BETWEEN BUILDINGS
(N) CONCRETE PAD
SEE S500
WILSHIRE MINNIE
1233 E WILSHIRE AVE UNIT# MTR01
1401 S MINNIE ST UNIT# MTR01
1403 S MINNIE ST UNIT# MTR01
APN: 014-251-49
DEVELOPER:
C&C DEVELOPMENT
30'-2"
4'3'10'-6"
3'
13'-9"
11'-10"
12'-9"
11
'
-
1
"
6'
-
3
"
M
A
X
4'
-
0
"
M
I
N
FR
O
M
G
R
A
D
E
B (N) NGO METER SOCKET ≤ 200A
NTS
10"
MIN.
MIN. CLEARANCE
TO OBSTRUCTIONS
OR SIDE WALLS
36" MIN.
(N) HOUSEKEEPING PAD
THE PAD SHALL BE FLUSH WITH
THE BOTTOM OF THE SERVICE EQUIPMENT
AND EXTEND A MINIMUM OF THREE FEET.
10"
MIN.
18" MIN.
MIN. CLEARANCE TO
EDGE OF WINDOW
OR DOOR
- NGO METER WORKING SPACE
TO BE MAINTAINED.
- EQUIPMENT ABOVE OR BELOW
NGOM WILL NOT EXCEED
DEPTH OF NGOM.
- NGOM TO BE MOUNTED ON
STRUT IF NEEDED TO
ACCOUNT FOR ANY DEPTH
DIFFERENCES.
- CENTER OF METER CAN NOT
TO EXCEED 6'-3" MAX, 4'-0" MIN.
-EQUIPMENT AND CONDUIT
SHOWN IS DIAGRAMMATIC
ONLY. SEE LINE DRAWINGS
FOR CONDUIT SIZING.
NOTES
MIN. CLEARANCE TO
PLUMBING FIXTURES
EXTENDING 6" OUT
FROM WALL SURFACE
6'
-
6
"
M
I
N
H
E
I
G
H
T
CL
E
A
R
A
N
C
E
FR
O
M
G
R
A
D
E
(E) GRADE
A AC DISCONNECT
(E) GRADE
75
"
M
A
X
HE
I
G
H
T
F
R
O
M
G
R
A
D
E
NOTES
- INSTALLED AT VERTICAL
HIEGHT OF BEWTEEN 48" MIN
AND 75" MAX, MEASURED
FROM GROUND TO TOP OF
ENCLOSURE
-EQUIPMENT AND CONDUIT
SHOWN IS DIAGRAMMATIC
ONLY. SEE LINE DRAWINGS
FOR CONDUIT SIZING.
DISCONNECT
(N) PV UTILITY
DISCONNECT
C INVERTER CLEARANCE - SOLAREDGE HOME HUB
MIN. CLEARANCE
BACK TO BACK
INVERTERS 8" MIN.
CLEAR
16" MIN.
CLEAR
8" MIN.
CLEAR
MIN. CLEARANCE
VERTICALLY
STACKED INVERTERS
8" MIN.
CLEAR
MIN. CLEARANCE
SIDE-BY-SIDE INVERTERS
- LISTED MIN. CLEARANCES FOR
INVERTER TO OTHER
OBJECTS, UNLESS NOTED
- MIN. CLEARANCES REQUIRED
FOR HEAT DISSIPATION
- CONDUIT MAY BE REQUIRE
ADDITIONAL CLEARANCE
-EQUIPMENT AND CONDUIT
SHOWN IS DIAGRAMMATIC
ONLY. SEE LINE DRAWINGS
FOR CONDUIT SIZING.
NOTES
8" MIN.
CLEAR
4" MIN.
CLEAR
4" MIN.
CLEAR
4" MIN.
CLEAR
46.4"
9.84"
BATTERY WEIGHT: 262LBS
31.1" 8" MIN. CLEAR
MIN. CLEARANCE
BATTERY SHOWN ON
OPTIONAL FLOOR STAND
KIT
SOLAREDGE ENERGY BANK
BAT-10K1P
D BESS CLEARANCE - SOLAREDGE ENERGY BANK
·LISTED MIN. CLEARANCES FOR ENERGY BANK TO OTHER
OBJECTS AS REQUIRED BY MANUFACTURER. NEC 110.3(B)
·BATTERY CAN BE WALL MOUNTED OR USE MANUFACTURES
FLOOR STAND KIT.
·8" MIN. CLEARANCES REQUIRED FOR HEAT DISSIPATION
·CONDUIT MAY REQUIRE ADDITIONAL CLEARANCE.
·EQUIPMENT AND CONDUIT SHOWN IS DIAGRAMMATIC ONLY.
·WORKING CLEARANCES SHALL BE IN ACCORDANCE WITH NEC
110.26 FOR ANY COMPONENTS THAT ARE LIKELY TO REQUIRE
EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE
WHILE ENERGIZED.
·BATTERIES SHALL NOT BE INSTALLED IN DIRECT SUNLIGHT
WITH OUT SHADE COVER
NOTES
8" MIN.
CLEAR
8" MIN.
CLEAR
8" MIN.
CLEAR
SOLAREDGE ENERGY BANK
WITH 4 BATTERIES ON FLOOR STAND KITS
53.15"
MIN.
6.3"
13.78"
1ST BATTERY FLOOR
STAND TO BE ANCHORED
TO WALL/RACK
SIDE BRACKETS
FOR
ATTACHING
BATTERIES
MIN. CLEAR IF
WALL MOUNTING
DC
CONNECTION
LOCATION
(N) AC DISCONNECT
GENERAL NOTES
·FIELD VERIFY ALL MEASUREMENTS
·ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND ANY OTHER REGULATING AUTHORITIES
WHICH HAVE AUTHORITY OVER ANY PORTION OF THE WORK.
·DRAWINGS HAVE BEEN DETAILED IN COMPLIANCE WITH UL LISTING REQUIREMENTS, OSFM SOLAR
PHOTOVOLTAIC INSTALLATION REQUIREMENTS, AND BUILDING CODES FOR THE MATERIALS SPECIFIED. PRIOR
TO COMMENCEMENT OF ANY WORK, THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND NOTIFY THE
DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE FROM SUNRUN OF ANY DISCREPANCIES. ANY WORK
PERFORMED IN CONFLICT WITH THE CONTRACT DOCUMENTS SHALL BE CORRECTED AT THE
SUBCONTRACTORS SOLE EXPENSE.
·SUBCONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO SUNRUN FOR APPROVAL BEFORE
MAKING ANY CHANGES OR DEVIATION FROM PLANS BEFORE WRITTEN APPROVAL FROM SUNRUN PLACES
LIABILITY ON THE SUBCONTRACTOR.
·ALL EQUIPMENT SHALL BE MOUNTED AS SHOWN. WHERE DETAILS ARE NOT PROVIDED, CONTRACTOR SHALL
USE STANDARD CONSTRUCTION PRACTICES.
·ALL SURFACES SHALL BE PATCHED AND PAINTED AROUND NEW DEVICES AND EQUIPMENT TO MATCH EXISTING
FINISHES. ANY METAL SHAVINGS FROM SITE WORK SHALL BE CLEANED FROM ALL SURFACES WHERE OXIDIZED
OR CONDUCTIVE METAL SHAVINGS MY CAUSE RUST, ELECTRICAL SHORT CIRCUITS, OR OTHER DAMAGE.
·APPROVALS FROM BUILDING INSPECTORS SHALL NOT CONSTITUTE AUTHORITY TO DEVIATE FROM THE
DRAWINGS.
·ACCESS AND WORKING SPACE SHALL BE PROVIDED AND MAINTAINED ABOUT ALL ELECTRICAL EQUIPMENT TO
PERMIT READY AND SAFE OPERATION AND MAINTENANCE OF SUCH EQUIPMENT IN ACCORDANCE WITH THE
CALIFORNIA ELECTRICAL CODE AND THE MANUFACTURER'S INSTRUCTIONS.
·ELECTROCHEMICAL ESS SHALL BE SEGREGATED INTO GROUPS NOT EXCEEDING 80 KWH PER CFC 127.5.1 AND
UL9540A REPORT. EACH GROUP SHALL BE SEPARATED A MINIMUM OF 3 FEET (914 MM) FROM OTHER GROUPS
AND FROM WALLS IN THE STORAGE ROOM OR AREA. THE STORAGE ARRANGEMENTS SHALL COMPLY WITH
CHAPTER 10.
·AREAS WITHIN 10 FEET (3048 MM) ON EACH SIDE OF OUTDOOR ESS SHALL BE CLEARED OF COMBUSTIBLE
VEGETATION AND OTHER COMBUSTIBLE GROWTH. SINGLE SPECIMENS OF TREES, SHRUBBERY OR CULTIVATED
GROUND COVER SUCH AS GREEN GRASS, IVY, SUCCULENTS OR SIMILAR PLANTS USED AS GROUND COVER
SHALL BE PERMITTED TO BE EXEMPT PROVIDED THAT THEY DO NOT FORM A MEANS OF READILY TRANSMITTING
FIRE.
·OUTDOOR INSTALLATIONS SHALL BE IN ACCORDANCE WITH SECTIONS 1207.8.1 THROUGH 1207.8.3. EXTERIOR
WALL INSTALLATIONS FOR INDIVIDUAL ESS UNITS ARE 9.7 KWH AND DO NOT EXCEED 20 KWH. ESS OUTDOOR
INSTALLATION SHALL BE IN ACCORDANCE WITH SECTION 1207.8.4.
··THE MAXIMUM ENERGY CAPACITY OF INDIVIDUAL ESS UNITS SHALL NOT EXCEED 20 KWH.
··THE ESS SHALL COMPLY WITH APPLICABLE REQUIREMENTS IN SECTION 1207.
··THE ESS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND THEIR
LISTING.
··INDIVIDUAL ESS UNITS SHALL BE SEPARATED FROM EACH OTHER BY AT LEAST 8" PER MANUFACTURER
INSTRUCTIONS AND UL9540A REPORT
·THE ESS SHALL BE SEPARATED FROM DOORS, WINDOWS, OPERABLE OPENINGS INTO BUILDINGS OR HVAC
INLETS BY AT LEAST 3 FEET PER UL9540A REPORT
·ESS LOCATED OUTDOORS SHALL BE SEPARATED BY A MINIMUM OF 10 FEET (3048 MM) FROM EXPOSURES
LISTED ON CFC 1207.8.3.
1'1'
4"
1'1'1'
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
ELECTRICAL PLAN VIEWS
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
E202
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#ESTAMP
(N) PV POINT OF INTERCONNECTION (POI-7)
(N) PV PRODUCTION METER SOCKET 1425 S MINNIE
ST UNIT# MTR01 PV PRODUCTION METER
REFERENCE METER NUMBER: 222013-124043
(N) UTILITY AC DISCONNECT (ACDS-7.1)
(N) MAINTENANCE AC DISCONNECT (ACDS-7.2)
(N) AC LOAD CENTER (LC-7.1)
(N) PV INVERTER AND ESS AC DISCONNECT (INV-7.1)
(N) PV INVERTER AND ESS AC DISCONNECT (INV-7.2)
E EQUIPMENT PLAN - POI-7 1425 MINNIE ST
SCALE: 3/16" = 1'-0"
(N) 58.2 kWh ESS GROUP OF
(6) SOLAREDGE BAT-10K1P BATTERIES WALL MOUNTED
(EACH BATTERY 9.7KWh)
1425 MINNIE ST
1207.8.3
1207.4.2 & 110.26(A)(1)
WORKING CLEARANCE
1429 MINNIE ST
F ESS ELEVATION - POI-7 1425 MINNIE ST
SCALE: 3/8" = 1'-0"
1425 MINNIE ST
(N) AC LOAD CENTER (LC-7.1)
(N) PV INVERTER AND ESS AC DISCONNECT (INV-7.1)
(N) PV INVERTER AND ESS AC DISCONNECT (INV-7.2)
(N) 58.2 kWh ESS GROUP OF
(6) SOLAREDGE BAT-10K1P BATTERIES WALL MOUNTED
3'-6"11'-10"
35'-11"
DISTANCE
BETWEEN
BUILDIGNS
WILSHIRE MINNIE
1425 S MINNIE ST UNIT# MTR01
APN: 014-251-50
DEVELOPER:
C&C DEVELOPMENT
11
'
-
0
"
10
'
-
1
"
LEGEND
STRING PATH
GENERAL NOTES
·FIELD VERIFY ALL MEASUREMENTS
·SEE SHEET E-100 FOR LEGEND OF SYMBOLS
STRING ID. X
INVERTER ID. #
INTERCONNECTION ID. #
INCREMENT
COUNT
1.1B.A
#
1209 E WILSHIRE AVE
1213 E WILSHIRE AVE
1.1.A
2
3
4
5
6
7
8
9
10
11
12
13
1.1.A
1.1.B
2
3
4
5
6
7
8
9
10
11
12
13
1.
1
.
B
1.
1
.
C
2
3
4
5
6
7
8
9
10
11
12
13
1.
1
.
C
1.2.A
2
3
4
5
6
7
8
9
10
11
12
13
1.2.A
1.2.B
2
3
4
5
6
7
8
9
10
11
12
13
1.
2
.
B
1.
2
.
C
2
3
4
5
6
7
8
9
10
11
12
13
1.
2
.
C
RB03
TL: 5° AZ: 270°
RB04
TL: 5° AZ: 90°
RB05
TL: 5° AZ: 270°
RB06
TL: 5° AZ: 90°
1201 E WILSHIRE AVE
1.3.A
2
3
4
5
6
7
8
9
10
11
1.3.A
1.3.B
2
3
4
5
6
7
8
9
10
11
1.
3
.
B
1.
4
.
A
2
3
4
5
6
7
8
9
10
11
1.
4
.
A
1.
4
.
B
2
3
4
5
6
7
8
9
10
11
1.
4
.
B
RB01
TL: 5° AZ: 270°
RB02
TL: 5° AZ: 90°
AVE UNIT# ELE01AVE UNIT# ELE01
PL
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
ELECTRICAL STRINGING
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
E300
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#ESTAMP
SCALE: 1/8" = 1'-0"
ADDRESSES 1201,1209 & 1213 STRINGING • POI-1A
PV INVERTERS
INTERCONNECTION LOCATION
(1209 WILSHIRE AVE)
BESS LOCATION
POI-1 MODULE ALLOCATION
STR-A STR-B STR-C
UNIT INVERTER MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG
[TILT,AZM]
MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG
[TILT,AZM]
MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG
[TILT,AZM]
INV-1.1 SOLAREDGE SE11400H-US HOME
HUB [240V] [SI1-SB] [CRD-PCS NEM]
Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RB03 [5°, 270°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (7) RB03 [5°, 270°]; (7) RB04 [5°, 90°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RB04 [5°, 90°];
INV-1.2 SOLAREDGE SE11400H-US HOME
HUB [240V] [SI1-SB] [CRD-PCS NEM]
Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RB05 [5°, 270°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (3) RB05 [5°, 270°]; (11) RB06 [5°, 90°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RB06 [5°, 90°];
INV-1.3 SOLAREDGE SE7600H-US HOME
HUB [240V] [SI1-SB] [CRD-PCS NEM]
Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RB01 [5°, 270°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (8) RB01 [5°, 270°]; (4) RB02 [5°, 90°];
INV-1.4 SOLAREDGE SE7600H-US HOME
HUB [240V] [SI1-SB] [CRD-PCS NEM]
Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RB02 [5°, 90°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RB02 [5°, 90°];
SITE PLAN KEY
E302
E303
E301
E300
WILSHIRE MINNIE
1209 E WILSHIRE AVE UNIT# MTR02
1209 3/4 E WILSHIRE AVE UNIT# ELE01
APN: 014-251-49
DEVELOPER:
C&C DEVELOPMENT
LEGEND
STRING PATH
GENERAL NOTES
·FIELD VERIFY ALL MEASUREMENTS
·SEE SHEET E-100 FOR LEGEND OF SYMBOLS
STRING ID. X
INVERTER ID. #
INTERCONNECTION ID. #
INCREMENT
COUNT
1.1B.A
#
1221 E WILSHIRE AVE
1225 E WILSHIRE AVE
2.1.A
2
3
4
5
6
7
8
9
10
11
12
13
2.1.A
2.1.B
2
3
4
5
6
7
8
9
10
11
12
13
2.
1
.
B
2.
1
.
C
2
3
4
5
6
7
8
9
10
11
12
13
2.
1
.
C
2.2.A
2
3
4
5
6
7
8
9
10
11
12
2.2.A
2.2.B 2
3
4
5
6
7
8
9
10
11
2.2.B
2.2.C
2
3
4
5
6
7
8
9
10
11
2.
2
.
C
2.
3
.
A
2
3
4
5
6
7
8
9
10
11
12
2.
3
.
A
2.
3
.
B
2
3 4
5
6
7
8
9
10
11
2.
3
.
B
2.
3
.
C
2
3
4
5
6
7
8
9
10
11
2.
3
.
C
RB07
TL: 5° AZ: 270°
RB08
TL: 5° AZ: 90°
RF01
TL: 10° AZ: 270°
RF02
TL: 10° AZ: 90°
1225 E WILSHIRE AVE
1229 E WILSHIRE AVE
1401 S MINNIE ST
1235 E WILSHIRE AVE
3.1.A
2
3
4
5
6
7
8
9
10
11
3.1.A
3.1.B
2
3
4
5
6
7
8 9
10
11
3.1.B
3.1.C
2
3
4
5
6
7
8
9
10
11
3.1.C
3.2.A
2
3
4
5
6
7
8
9
10
11
3.
2
.
A
3.
2
.
B
2
3
4
5
6
7
8
9
10 11
3.
2
.
B
3.
2
.
C
2
3
4
5
6
7
8
9
10
11
3.
2
.
C
3.
3
.
A
2
3
4
5
6
7
8
9
10
11
12
13
3.
3
.
A
3.
3
.
B
2 3
4
5
6 7
8
9
10
11
12
13
3.
3
.
B
3.
3
.
C
2
3
4
5 6
7
8
9
10
11
12
13
3.
3
.
C
11
12
13
4.1.
A
4.1.
B
2
3
4
5
6
7
8
9
10
11
12
13
4.1.
B
4.1.
C
2
3
4
5
6
7
8
9
10
11
12
13
4.2.
A
4.2.
B
2
3
4
5
6
7
8
9
10
RB10
TL: 5° AZ: 142°
RF03
TL: 10° AZ: 270°
RF04
TL: 10° AZ: 90°
RF05
TL: 19° AZ: 270°
RF06
TL: 19° AZ: 90°
RF08
TL: 15° AZ: 270°
1229 3/4 E WILSHIRE
AVE UNIT# ELE01
PL
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
ELECTRICAL STRINGING
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
E301
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#ESTAMP
SCALE: 1/8" = 1'-0"
ADDRESSES 1221,1225 STRINGING • POI-2A SCALE: 1/8" = 1'-0"
ADDRESSES 1229,1235 STRINGING • POI-3B
BESS
LOCATION
INTERCONNECTION LOCATION
(1221 E WILSHIRE AVE)
PV INVERTERS
INTERCONNECTION LOCATION
(1229 E WILSHIRE AVE)
BESS LOCATION
PV
INVERTERS
POI-2 MODULE ALLOCATION
STR-A STR-B STR-C
UNIT INVERTER MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG
[TILT,AZM]
MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG
[TILT,AZM]
MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG
[TILT,AZM]
INV-2.1 SOLAREDGE SE11400H-US HOME
HUB [240V] [SI1-SB] [CRD-PCS NEM]
Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RB07 [5°, 270°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (11) RB07 [5°, 270°]; (3) RB08 [5°, 90°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RB08 [5°, 90°];
INV-2.2 SOLAREDGE SE11400H-US HOME
HUB [240V] [SI1-SB] [CRD-PCS NEM]
Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]13 U650 (13) RF01 [10°, 270°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RF01 [10°, 270°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (7) RF01 [10°, 270°]; (5) RF02 [10°, 90°];
INV-2.3 SOLAREDGE SE11400H-US HOME
HUB [240V] [SI1-SB] [CRD-PCS NEM]
Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]13 U650 (13) RF02 [10°, 90°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RF02 [10°, 90°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RF02 [10°, 90°];
POI-3 MODULE ALLOCATION
STR-A STR-B STR-C
UNIT INVERTER MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG
[TILT,AZM]
MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG
[TILT,AZM]
MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG
[TILT,AZM]
INV-3.1 SOLAREDGE SE11400H-US HOME
HUB [240V] [SI1-SB] [CRD-PCS NEM]
Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RF03 [10°, 270°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RF03 [10°, 270°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RF03 [10°, 270°];
INV-3.2 SOLAREDGE SE11400H-US HOME
HUB [240V] [SI1-SB] [CRD-PCS NEM]
Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (4) RF03 [10°, 270°]; (8) RF04 [10°, 90°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RF04 [10°, 90°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RF04 [10°, 90°];
INV-3.3 SOLAREDGE SE11400H-US HOME
HUB [240V] [SI1-SB] [CRD-PCS NEM]
Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RF05 [19°, 270°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (6) RF05 [19°, 270°]; (8) RF06 [19°, 90°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RF06 [19°, 90°];
SITE PLAN KEY
E302
E303
E301
E300
WILSHIRE MINNIE
1221 E WILSHIRE AVE UNIT# MTR02
1221 3/4 E WILSHIRE AVE UNIT# ELE01
1229 E WILSHIRE AVE UNIT# MTR02
1229 3/4 E WILSHIRE AVE UNIT# ELE01
APN: 014-251-49
DEVELOPER:
C&C DEVELOPMENT
LEGEND
STRING PATH
GENERAL NOTES
·FIELD VERIFY ALL MEASUREMENTS
·SEE SHEET E-100 FOR LEGEND OF SYMBOLS
STRING ID. X
INVERTER ID. #
INTERCONNECTION ID. #
INCREMENT
COUNT
1.1B.A
#
1233 E WILSHIRE AVE
1401 S MINNIE ST
1235 E WILSHIRE AVE
2
3
4
5
6
7
8
9
10
11
12
13
3.
3
.
A
3.
3
.
B
4
5
6 7
8
9
10
11
12
13
3.
3
.
B
3.
3
.
C
2
3
4
5 6
7
8
9
10
11
12
13
3.
3
.
C
4.1.
A
2
3
4
5
6
7
8
9
10
11
12
13
4.1.
A
4.1.
B
2
3
4
5
6
7
8
9
10
11
12
13
4.1.
B
4.1.
C
2
3
4
5
6
7
8
9
10
11
12
13
4.1.
C
4.2.
A
2
3
4
5
6
7
8
9
10
11
12
13
4.2.
A
4.2.
B
2
3
4
5
6
7
8
9
10
11
12
13
4.2.
B
RB09
TL: 5° AZ: 322°
RB10
TL: 5° AZ: 142°
1401 S MINNIE ST
5.1.A 2 3 4 5 6 7 8 9 10 11 12 5.1.A 5.1.B 2 3 4 5
67891011125.1.B5.1.C2345678910115.1.C5.2.A2
3
4
5
6
7 8
9 10 11 12 5.2.A
5.2.B 2 3 4 5 6 7
8910115.2.B 5.3.A2345678910
11 12 5.3.A 5.3.B 2 3 4 5 6 7
8
9
10
5.
3
.
B
RB10
TL: 5° AZ: 142°
RF07
TL: 15° AZ: 0°
RF08
TL: 15° AZ: 270°
RF09
TL: 15° AZ: 180°
RF10
TL: 15° AZ: 90°
PL
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
ELECTRICAL STRINGING
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
E302
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#ESTAMP
SCALE: 3/32" = 1'-0"
ADDRESS 1233 STRINGING • POI-4A SCALE: 3/32" = 1'-0"
ADDRESS 1401 STRINGING • POI-5B
BESS LOCATION
(ON CONCRETE PAD)
INTERCONNECTION LOCATION
(1233 E WILSHIRE AVE)
PV INVERTERS
(RACK ON
CONCRETE PAD)
INTERCONNECTION LOCATION
(1401 S MINNIE ST)
BESS LOCATION
PV INVERTERS
POI-4 MODULE ALLOCATION
STR-A STR-B STR-C
UNIT INVERTER MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG
[TILT,AZM]
MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG
[TILT,AZM]
MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG
[TILT,AZM]
INV-4.1 SOLAREDGE SE11400H-US HOME
HUB [240V] [SI1-SB] [CRD-PCS NEM]
Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RB09 [5°, 322°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RB09 [5°, 322°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RB09 [5°, 322°];
INV-4.2 SOLAREDGE SE7600H-US HOME
HUB [240V] [SI1-SB] [CRD-PCS NEM]
Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (2) RB09 [5°, 322°]; (12) RB10 [5°, 142°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RB10 [5°, 142°];
POI-5 MODULE ALLOCATION
STR-A STR-B STR-C
UNIT INVERTER MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG
[TILT,AZM]
MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG
[TILT,AZM]
MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG
[TILT,AZM]
INV-5.1 SOLAREDGE SE11400H-US HOME
HUB [240V] [SI1-SB] [CRD-PCS NEM]
Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]13 U650 (13) RF07 [15°, 0°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]13 U650 (13) RF07 [15°, 0°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RF07 [15°, 0°];
INV-5.2 SOLAREDGE SE7600H-US HOME
HUB [240V] [SI1-SB] [CRD-PCS NEM]
Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]13 U650 (1) RF07 [15°, 0°]; (5) RF08 [15°, 270°]; (7)
RF09 [15°, 180°];
Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RF09 [15°, 180°];
INV-5.3 SOLAREDGE SE7600H-US HOME
HUB [240V] [SI1-SB] [CRD-PCS NEM]
Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]13 U650 (13) RF09 [15°, 180°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]11 U650 (7) RF09 [15°, 180°]; (4) RF10 [15°, 90°];
SITE PLAN KEY
E302
E303
E301
E300
WILSHIRE MINNIE
1233 E WILSHIRE AVE UNIT# MTR01
1401 S MINNIE ST UNIT# MTR01
APN: 014-251-49
DEVELOPER:
C&C DEVELOPMENT
LEGEND
STRING PATH
GENERAL NOTES
·FIELD VERIFY ALL MEASUREMENTS
·SEE SHEET E-100 FOR LEGEND OF SYMBOLS
STRING ID. X
INVERTER ID. #
INTERCONNECTION ID. #
INCREMENT
COUNT
1.1B.A
#
6.1.A 2 3 4 5 6 7 8 9 10 11 12
136.1.A6.1.B234
5 6 7 8 9 10 11 12 13 6.1.B 6.2.A 2 3
4 5
6
7
8
9
10
11
12
13
6.2.A
6.2.B
2
3
4
5 6
7
8
9
10
11
12
13
6.2.B
RB11
TL: 5° AZ: 180°
RB12
TL: 5° AZ: 180°
RB13
TL: 5° AZ: 270°
RB14
TL: 5° AZ: 90°
1403
S MINNIE ST
1425 S MINNIE ST
7.1.A2345678910117.1.A7.1.B234
5 6 7 8 9 10 7.1.B
7.1.C 2 3 4 5 6 7 8
9 10 7.1.C
7.2.A 2 3
4 5
6
7
89
10
11
7.
2
.
A
7.
2
.
B
2
3
4 5
6
7
89
10
7.
2
.
B
RF11
TL: 10° AZ: 0°
RF12
TL: 10° AZ: 180°
RF13
TL: 10° AZ: 270°
RF14
TL: 10° AZ: 90°
PL
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
ELECTRICAL STRINGING
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
E303
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#ESTAMP
SCALE: 3/32" = 1'-0"
ADDRESS 1403 STRINGING • POI-6 A
BESS LOCATION
INTERCONNECTION LOCATION
(1403 S MINNIE ST)
PV INVERTERS
SCALE: 3/32" = 1'-0"
ADDRESS 1425 STRINGING • POI-7A
POI-6 MODULE ALLOCATION
STR-A STR-B
UNIT INVERTER MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM]MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG [TILT,AZM]
INV-6.1 SOLAREDGE SE7600H-US HOME HUB [240V]
[SI1-SB] [CRD-PCS NEM]
Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RB11 [5°, 180°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (4) RB11 [5°, 180°]; (10) RB12 [5°, 180°];
INV-6.2 SOLAREDGE SE7600H-US HOME HUB [240V]
[SI1-SB] [CRD-PCS NEM]
Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (5) RB12 [5°, 180°]; (6) RB13 [5°, 270°]; (3) RB14 [5°,
90°];
Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RB14 [5°, 90°];
POI-7 MODULE ALLOCATION
STR-A STR-B STR-C
UNIT INVERTER MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG
[TILT,AZM]
MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG
[TILT,AZM]
MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG
[TILT,AZM]
INV-7.1 SOLAREDGE SE11400H-US HOME
HUB [240V] [SI1-SB] [CRD-PCS NEM]
Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RF11 [10°, 0°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]11 U650 (4) RF11 [10°, 0°]; (7) RF12 [10°, 180°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]11 U650 (11) RF12 [10°, 180°];
INV-7.2 SOLAREDGE SE7600H-US HOME
HUB [240V] [SI1-SB] [CRD-PCS NEM]
Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (5) RF12 [10°, 180°]; (7) RF13 [10°, 270°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]11 U650 (1) RF13 [10°, 270°]; (10) RF14 [10°, 90°];
SITE PLAN KEY
E302
E303
E301
E300
BESS LOCATION
PV INVERTERS
INTERCONNECTION LOCATION
(1425 S MINNIE ST)
WILSHIRE MINNIE
1403 S MINNIE ST UNIT# MTR01
1425 S MINNIE ST UNIT# MTR01
APN: 014-251-49 / 014-251-50
DEVELOPER:
C&C DEVELOPMENT
LEGEND
STRING PATH
GENERAL NOTES
·FIELD VERIFY ALL MEASUREMENTS
·SEE SHEET E-100 FOR LEGEND OF SYMBOLS
STRING ID. X
INVERTER ID. #
INTERCONNECTION ID. #
INCREMENT
COUNT
1.1B.A
#
BLDG 1425
BLDG 1429
RF11
TL: 10° AZ: 0°
RF12
TL: 10° AZ: 180°RF13
TL: 10° AZ: 270°
RF14
TL: 10° AZ: 90°
RF15
TL: 10° AZ: 270°
RF16
TL: 10° AZ: 90°RF17
TL: 10° AZ: 0°
RF18
TL: 10° AZ: 180°
10.1.A 2 3 4
5678910
11 12 13 10.1.A 10.1.B 2 3 4 5 6 7 8 9 10
11121310.1.B10.1.C234567
8 9 10 11 12 13 10.1.C
10.2.A23
4 5 6 7 10.2.A
10
.
2
.
B
2
3 4
5
6
7
10
.
2
.
B
10
.
2
.
C
2
3
4
5
6 7
8
9
10
.
2
.
C
11.1.A 2 3 4 5 6 7
8910111211.1.A
11.1.B234567
8 9 10 11 12 11.1.B
11.1.C234567
8 9 10 11 11.1.C 11.2.A 2 3 4 5 6 7 11.2.A
11
.
2
.
B
2
3
4
5
6
7
11
.
2
.
B
11
.
2
.
C
2
3
4
5
6
7
8
9
11
.
2
.
C
C:\USERS\EMILIANO.MORALES\DESKTOP\WORKING PROJECTS\1235_WILSHIRE_MINNIE\CD100\WILSHIRE MINNIE_WORKINGDOCS_V0\WILSHIRE MINNIE.DWG
ELECTRICAL STRINGING
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
PROJECT DETAILS:
PV SYSTEM:
·355.88 kW DC
·250.8 kW AC
·331.612 CEC AC
ENERGY STORAGE:
·243.2 kW AC
·756.6 kWH
E304
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER: FINS_TM
ORIGINAL
CONTRACT NUMBER:
3003197607
PJT #: PROP-001235
SCALE: 1/8" = 1'-0"
BLDG 1425,1429 STRINGING • POI-10 & POI-11A
INTERCONNECTION LOCATION
BESS LOCATION
PV INVERTER AND
ESS AC DISCONNECT
POI-10 MODULE ALLOCATION
STR-A STR-B STR-C
UNIT INVERTER MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG
[TILT,AZM]
MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG
[TILT,AZM]
MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG
[TILT,AZM]
INV-10.1 SOLAREDGE SE11400H-US HOME
HUB [SI1-SB]
Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RF11 [10°, 0°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (10) RF11 [10°, 0°]; (4) RF12 [10°, 180°]; Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]14 U650 (14) RF12 [10°, 180°];
INV-10.2 SOLAREDGE SE7600H-US HOME
HUB [SI1-SB]
Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]8 U650 (8) RF12 [10°, 180°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]8 U650 (8) RF13 [10°, 270°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]10 U650 (10) RF14 [10°, 90°];
POI-11 MODULE ALLOCATION
STR-A STR-B STR-C
UNIT INVERTER MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG
[TILT,AZM]
MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG
[TILT,AZM]
MODULE TOTAL MODS OPT BREAKOUT - (QTY) ROOF TAG
[TILT,AZM]
INV-11.1 SOLAREDGE SE11400H-US HOME
HUB [SI1-SB]
Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]13 U650 (13) RF18 [10°, 180°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]13 U650 (13) RF18 [10°, 180°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]12 U650 (12) RF17 [10°, 0°];
INV-11.2 SOLAREDGE SE7600H-US HOME
HUB [SI1-SB]
Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]8 U650 (8) RF17 [10°, 0°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]8 U650 (8) RF15 [10°, 270°];Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]10 U650 (10) RF16 [10°, 90°];
STRUT CONDUIT CLAMP
12 GA GALVANIZED
STEEL
SIZED AS APPROPRIATE
1-5/8" STRUT CHANNEL
12 GA, HDG
NOTE: ALL HOLES FOR CONDUIT SHALL BE PROVIDED WITH CONDUIT FITTINGS
HAVING AN ENVIRONMENTAL RATING APPROVED TO MAINTAIN NEMA 3R
ENCLOSURE RATING (UL508A, TABLE 19.2). IN GENERAL COMPONENTS MARKED
"WEATHERPROOF" OR "RAINPROOF" SHALL BE INSTALLED ONLY BELOW THE
LOWEST UNINSULATED LIVE PARTS WITHIN THE ENCLOSURE. CONDUIT
OPENINGS ABOVE THE LOWEST UNINSULATED LIVE PARTS SHALL BE PROVIDED
WITH CONDUIT FITTINGS MARKED "WET LOCATION" OR "RAINTIGHT".
WOOD: MIN. 2" EMBED W/ 3/8" LAG TO
(E) STUD OR 4"xBLOCK W/ A34 EA.
END T&B
MASONRY: USE ICC-APPROVED
MASONRY ANCHORS
STEEL: USE SELF-DRILLING,
SELF-TAPPING SCREWS
OPTION 1 OPTION 2
2-HOLE 12 GA GALV
STEEL STRAP
NTS
CONDUIT SUPPORT - WALLC
24
"
S
U
G
G
.
D
E
P
T
H
18
"
M
I
N
.
C
O
V
E
R
8"
(E) ASPHALT/CONCRETE
(N) FINISHED GRADE,
REPAIR CAP TO MATCH
EXISTING.
RED WARNING TAPE
W/ TRACE WIRE
APPROVED BACKFILL
PVC CONDUIT (REFER TO
PLANS AND WIRE
SCHEDULE FOR ACTUAL
NUMBER AND LOCATION
OF CONDUITS).
3" MIN.
NTS
TRENCH THROUGH PAVEMENT NON-TRAFFIC DETAILD
USE EXISTING HOLES TO
TERMINATE CONDUCTORS,
TORQUE PER
MANUFACTURER
REQUIREMENTS. USE
GRADE 5 OR LARGER BOLT.
UL LISTED CRIMP RATED FOR 600
VOLTS CRIMPED IN 2 PLACES. USE
MANUFACTURER APPROVED
CRIMPING DEVICE ONLY AND
APPLY ANTIOXIDANT COMPOUND
BEFORE CRIMPING.
SIDE VIEWFRONT VIEW
(E) BUS
NOTE:
ALUMINUM CONDUCTORS SHALL NOT BE TERMINATED WITH MECHANICAL LUGS.
TORQUE MARK BOLT WITH PAINT
PEN AFTER TORQUING NUT/BOLT
B CONDUCTOR TERMINATION DETAIL
NTS
CONTINUOUS GROUND
STRIP INSULATION AT LUG
ENCLOSURE
LOCK NUT
GROUNDING BUSHING
WITH LAY-IN LUG
CONDUIT COMPRESSION FITTING
NTS
CONDUIT GROUNDING DETAILA
30
"
S
U
G
G
.
D
E
P
T
H
24
"
M
I
N
.
C
O
V
E
R
8"
(E) ASPHALT/CONCRETE (N) FINISHED GRADE,
REPAIR CAP TO MATCH
EXISTING.
RED WARNING TAPE
W/ TRACE WIRE
APPROVED BACKFILL
PVC CONDUIT (REFER TO
PLANS AND WIRE
SCHEDULE FOR ACTUAL
NUMBER AND LOCATION
OF CONDUITS).
3" MIN.
E TRENCH THROUGH PAVEMENT TRAFFIC DETAIL
NTS
4'-0" MIN
(N) PVC SWEEPER
BORE PIT
VARIES
NOTE:
4' BORE DEPTH TO BE MAINTAINED EXCEPT WHERE ELEVATION
CHANGES ARE
REQUIRED TO AVOID OBSTACLES
RECEIVING PIT
NTSFHORIZONTAL BORE DETAIL
NOTE:
ACCESSIBLE MEANS EXTERNAL TO ENCLOSURES FOR
CONNECTING INTERSYSTEM BONDING AND GROUNDING
CONDUCTORS SHALL BE PROVIDED. SEE NEC 250.94.
SERVICE DISCONNECT 1 OF 2
WHERE NEUTRAL TERMINAL BUS IS
INSULATED FROM THE ENCLOSURE,
INSTALL A MAIN BONDING JUMPER
OR SCREW WITH A GREEN SEE NEC
250.8, 250.28. NEUTRAL DISCONNECT
MEANS. SEE NEC 230.75.
WHERE SERVICE ENTRANCE
RACEWAY IS INSTALLED WITH
LOCKNUTS, INSTALL A GROUND
BUSHING OR DEVICE AND BOND TO
THE ENCLOSURE. SEE NEC 250.92
(B) (4).
GROUNDING ELECTRODE SYSTEM –
SEE NEC 250.50.
IF METALLIC CONDUIT, BONDING
REQUIRED (BOTH ENDS) SEE NEC
250.92.
GROUNDING ELECTRODE
CONDUCTOR – SEE NEC 250.62
FOR MATERIAL, NEC 250.64 FOR
INSTALLATION, AND NEC 250.66
FOR SIZE.
CONNECTION TO ELECTRODE –
CONNECT GROUNDING ELECTRODE
CONDUCTOR TO GROUNDING
ELECTRODE WITH LISTED GROUND
SEE NEC 250.70.
BONDING JUMPER SEE NEC
250.92 (A) (2). FOR SIZES,
SEE NEC 250.102 (C).
LAY IN LUG. WHERE LUG IS
INSULATED FROM
ENCLOSURE, INSTALL A
BONDING JUMPER OR
SCREW.
GROUNDED (NEUTRAL) SERVICE
ENTRANCE CONDUCTOR
FROM PV SYSTEM
SERVICE
DISCONNECT
2 OF 2
METER ENCLOSURE
G METER GROUNDING DETAIL
NTS
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
ELECTRICAL DETAILS
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
E400
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#ESTAMP
WILSHIRE MINNIE
1209 E WILSHIRE AVE UNIT# MTR02
1209 3/4 E WILSHIRE AVE UNIT# ELE01
1221 E WILSHIRE AVE UNIT# MTR02
1221 3/4 E WILSHIRE AVE UNIT# ELE01
1229 E WILSHIRE AVE UNIT# MTR02
1229 3/4 E WILSHIRE AVE UNIT# ELE01
1233 E WILSHIRE AVE UNIT# MTR01
1401 S MINNIE ST UNIT# MTR01
1403 S MINNIE ST UNIT# MTR01
1425 S MINNIE ST UNIT# MTR01
APN: 014-251-49 / 014-251-50
DEVELOPER: C&C DEVELOPMENT
RAIL
CHANNEL NUT
MODULE
FRAME
MID CLAMP ASSEMBLY
SS BONDING PIN
NOTE:
1.ADJUSTABLE END CLAMPS USE SAME BONDING PIN DESIGN TO
BOND MODULES TO RAIL
C MID CLAMP ASSEMBLY
NTS
NOTES:
1.INSTALL EXPANSION COUPLING EVERY 100' OF
STRAIGHT CONDUIT RUN
2.IF EXPANSION COUPLINGS ARE INSTALLED AT
LESS THAN 100'.THE DISTANCES OF
EXPANSION/CONTRACTION SHALL BE
ADJUSTED PROPORTIONALLY.
3.IF EXPANSION JOINT IS NOT PROVIDED WITH
INTERNAL BONDING JUMBER, AN EXTERNAL
BONDING JUMPER MUST BE INSTALLED.
INSTALL EXPANSION COUPLINGS SO THAT THE
LENGTH CHANGE FOR CONTINUOUS CONDUIT
DOES NOT EXCEED 1/4".
SEE NEC 352.44
FOR STEEL CONDUIT, MULTIPLY THE EXPANSIONS
LISTED IN TABLE 352.44 BY 0.2.
SEE NEC 300.7
0°F - EXTEND 3/8" BEYOND CENTER
60°F - CENTERED
30°F - EXTEND 3/16" BEYOND CENTER
90°F - EXTEND 3/16" BEYOND CENTER
120°F - EXTEND 3/8" BEYOND CENTER
CONDUIT TYPE COEFFICIENT (IN./IN/°F)TEMP °F EXPANSION/ 100FT (IN)
STEEL 6.5 X 10-6 120 0.94
PVC 3.4 X 10-5 120 4.87
B CONDUIT THERMAL EXPANSION DETAIL
NTS
D SNAPNRACK ULTRA RAIL BONDING SPLICE
NTS
RAIL GAP
RANGE
THERMAL EXPANSION GAP:
1/8" - 1/4"
RAIL EDGE MUST NOT PASS THE
BONDING CLIP EDGE, AS SHOWN.
SPLICE ALIGNMENT LIMITS
SNAPNRACK, UR-40/UR-45 RAIL
TORQUE ALL FASTENERS TO
THE SPECIFIED VALUES PRIOR
TO INSTALLING PV MODULES
SNAPNRACK, ULTRA RAIL SPLICE
SNAPNRACK, UR-40/UR-45 SPLICE INSALLED
SNAPNRACK BONDING CLIP, TYPE 2
FOR BONDING ACROSS RAILS
NOTE:
1.ALL HARDWARE IS INCLUDED FROM MANUFACTURER
2.REFER TO SNAPNRACK INSTALLATION MANUAL FOR 5/16"Ø
HARDWARE TORQUE SPEC
3.SPLICE POSITIONING:
3.1.APPROVED - ANYWHERE ALONG RAIL SPAN BETWEEN TWO
ROOF ATTACMENTS
3.2.NOT APPROVED - RAIL OVERHANGS / CANTILEVERS
4.USE OF THE UR-40/UR-45 SPLICE WITH UR-60 RAIL IS PROHIBITED
SNAPNRACK, UR-40 RAIL
1 3/4"
1 5/8"
1 1/2"
1 1/2"
SNAPNRACK, UR-45 RAIL
E SNAPNRACK OMNILUG
NTS
OMNILUG GROUND LUG ON ULTRA RAIL
OMNILUG MPLE ATTACHMENT ON ULTRA RAIL
GROUND LUG NOTE:
1.PLACE THE GROUNDING CONDUCTOR INTO THE
SLOT ON THE BONDING BRACKET UNDERNEATH THE
CONICAL WASHER ON THE SEMS BOLT.
1.1.GROUNDING CONDUCTOR MUST EXTEND
BEYOND THE ENTIRE CONICAL WASHER TO
ASSURE PROPER BONDING.
1.2.TIGHTEN THE MOUNTING BOLT TO 10.8 LB-FT.
2.OPTIMIZERS AND MICROINVERTERS SHOULD
ALWAYS BE INSTALLED PER SPECIFIC
MANUFACTURER'S INSTRUCTION.
MLPE NOTE:
1.PLACE THE MOUNTING PLATE CHASSIS OF THE MLPE
DEVICE ON THE BONDING BRACKET UNDERNEATH
THE CONICAL WASHER ON THE SEMS BOLT.
2.TIGHTEN THE MOUNTING BOLT TO 10.8 LB-FT.
2
1
3
EXPLODED VIEW
ITEM QTY
1
2
3
PARTS LIST
DESCRIPTION
1 SNAPNRACK, OMNILUG, BONDING BRACKET, SS
1 SEMS SCREW, HEX, 5-16IN-18 X 1-1-4IN, 7-8 OD CONICAL WSH, TOOTH, SS
1 SNAPNRACK CHANNEL NUT 5-16IN-18
TOP VIEW
SIDE VIEW
1.78
1.78
0.29
0.41
1.53
G SNR GROUND PATH DETAIL - SOLAREDGE
NTS
X M M M X
TO EGC
X M M M X
U M U U U
TO EGC
U M U U U
GROUND PATH
RAIL RAIL SPLICE MOUNT
EQUIPMENT GROUNDING
CONDUCTOR
GROUND LUG
SOLAREDGE
OPTIMIZER
M MODULE CLAMP
M = MIDCLAMP
X = X-END CLAMP
U = UNIVERSAL END
CLAMP
F SNAPNRACK FRAME MLPE ATTACHMENT
NTS
.66
.14
R.12 .63
.30
2.24
1.50 .50
.95
SOLAR MODULE
SNR MLPE FRAME
ATTACHMENT
MODULE LEVEL POWER
ELECTRONIC
SOLAR MODULE
FRAME
MODULE FRAME MLPE INSTALLATION VIEW
INTEGRATED
SMART CLIP
MODULE FRAME MLPE TOP VIEW
MODULE FRAME MLPE SIDE VIEW
SCE BARRIERS
SCE ESR-3: 16.11 PROTECTIVE BARRIERS (POSTS/ BOLLARDS) FOR SERVICE EQUIPMENT (1-26-2024)A
NOTES:
·MAINTAIN A MINIMUM OF 3' CLEAR AND LEVEL
WORKING SPACE IN FRONT OF ALL THE SERVICE
EQUIPMENT ENCLOSURES.
·90 DEG MIN. OPENING FOR SERVICE EQUIPMENT
DOORS/ PANELS.
·4" GALVANIZED STEEL PIPE (1/4" MIN. WALL)
FILLED WITH CONCRETE AND PAINTED "CAUTION
YELLOW."
·CONCRETE ENCASEMENT 6" MIN. IN STABLE SOIL,
12" MIN. IN SANDY OR UNSTABLE SOIL.
·BARRIERS MUST BE INSTALLED IN LINE WITH
EACH END OF SERVICE EQUIPMENT.
·4'-6" MIN. DISTANCE BETWEEN CENTER OF
BARRIERS.
2'-6"
CONCRETE
6" or 12"
FINAL
GRADE
CONCRETE
FILLED
CONCRETE
CAP
2'-6"
5'-0"
4'-6"
MAX.
3'-0"
MIN.
PULL CAN / SECTION
OR METERS
4'-6"
MAX.
NON-REMOVABLE
BARRIER POST DETAILPLAN VIEW
3"
PARKING SPACES
OR VEHICULAR
TRAFFIC
4'-6"
MAX.
3'-0"
MIN.
4'-6"
MAX.
3'-0"
MIN.
4'-6"
MAX.
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
ELECTRICAL DETAILS
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
E401
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#ESTAMP
WILSHIRE MINNIE
1209 E WILSHIRE AVE UNIT# MTR02
1209 3/4 E WILSHIRE AVE UNIT# ELE01
1221 E WILSHIRE AVE UNIT# MTR02
1221 3/4 E WILSHIRE AVE UNIT# ELE01
1229 E WILSHIRE AVE UNIT# MTR02
1229 3/4 E WILSHIRE AVE UNIT# ELE01
1233 E WILSHIRE AVE UNIT# MTR01
1401 S MINNIE ST UNIT# MTR01
1403 S MINNIE ST UNIT# MTR01
1425 S MINNIE ST UNIT# MTR01
APN: 014-251-49 / 014-251-50
DEVELOPER: C&C DEVELOPMENT
GENERAL ELECTRICAL NOTES MODULE CHARACTERISTICS
OPTIMIZER CHARACTERISTICS
SINGLE LINE DIAGRAM LEGEND
CURRENT TRANSFORMER
(DOT INDICATES DIRECTION)
METER
CIRCUIT BREAKER
SWITCH
PV MODULE
FUSE
INVERTER~
--
M
CELLULAR ANTENNA
DC COMBINER
TRANSFORMER
BATTERY MODULE
A
B TRANSFER SWITCH (ATS/ MTS)
JUNCTION BOX
+-
INTERCONNECTION NOTES
INTERCONNECTION NOTES
·SUPPLY SIDE INTERCONNECTIONS SHALL COMPLY WITH ART. 705.11 AND ART 230 FOR THE
INSTALLATION OF AN ADDITIONAL SERVICE ENTRANCE
·THE OVERCURRENT PROTECTION DEVICE ON THE SUPPLY SIDE OF THE SERVICE
DISCONNECTING MEANS SHALL BE WITHIN 10 FEET OF THE INTERCONNECTION POINT UNLESS
CABLE LIMITERS OR CURRENT-LIMITED CIRCUIT BREAKERS ARE INSTALLED ON EACH
UNGROUNDED CONDUCTOR AT THE POINT OF INTERCONNECTION PER ART. 705.11(C). THIS
OVERCURRENT DEVICE MUST BE SIZED FOR THE SHORT-CIRCUIT CURRENT SUPPLIED FROM THE
PRIMARY SOURCE(S) OF ELECTRICITY.
·SUPPLY SIDE INTERCONNECTIONS SHALL BE MADE IN ACCORDANCE WITH THE EQUIPMENT
MANUFACTURER'S INSTRUCTIONS AND SHALL NOT INVALIDATE THE NRTL LISTING OF THE
EQUIPMENT.
·RMC OR SCH 80 PVC TYPE CONDUIT SHALL BE USED TO ENCLOSE NEW SERVICE CONDUCTORS
USED FOR A SUPPLY SIDE INTERCONNECTION.
·NEW SERVICE CONDUCTORS USED FOR SUPPLY SIDE INTERCONNECTIONS SHALL BE INSTALLED
IN A SEPARATE RACEWAY FROM ANY LOAD SIDE CONDUCTORS WITHIN THE MAIN SWITCHBOARD
PER NEC 230.7.
GENERAL NOTES
·ALL ELECTRICAL WORK SHALL COMPLY WITH THE NEC 2020 CODE AS AMENDED BY
APPLICABLE STATE AND LOCAL CODES.
·EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED
BY PHASE AND SYSTEM PER ART 210.5.
·BRANCH CIRCUITS SUPPLIED FROM DC SYSTEMS MUST BE IDENTIFIED IN COMPLIANCE WITH
ART. 210.5(C)(2) WHERE DC POSITIVE (+) IS RED/ RED-STRIPED AND DC NEGATIVE (-) IS
BLACK/BLACK-STRIPED.
·ALL EQUIPMENT SHALL BE LISTED BY A NRTL IN COMPLIANCE WITH ART 110.3.
·DC CONDUCTORS INSIDE BUILDING SHALL BE IN METALLIC RACEWAY PER ART 690.31(D).
·ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS
REQUIRED BY NRTL LISTING.
·PARALLEL CONDUCTORS SHALL BE INSTALLED PER ART 310.10(G).
·ALL VALUES FOR Imp, Isc AND Vmp ARE PER MANUFACTURER'S LISTED DATA AT STC. MAXIMUM
VOLTAGE CALCULATED IN ACCORDANCE WITH ARTICLE NEC 690.7.
·REFER TO CURRENT MANUFACTURER'S PLANNING AND INSTALLATION MANUAL FOR
TORQUE SPECS FOR ALL BOLTS AND TERMINAL CONNECTIONS.
·BRANCH CIRCUITS RUN IN OUTDOOR ROOFTOP AMBIENT CONDITIONS SHALL BE INSTALLED
> 7/8 INCH ABOVE ROOF SURFACE.
·ALL PV CIRCUITS LOCATED OUTSIDE THE ARRAY BOUNDARY OR MORE THAN 3 FT FROM THE
POINT OF ENTRY INSIDE A BUILDING SHALL BE LIMITED TO NOT MORE THAN 30 VOLTS
WITHIN 30 SECONDS, CIRCUITS INSIDE THE ARRAY BOUNDARY OR NOT MORE THAN 3 FT
FROM THE POINT OF PENETRATION SHALL BE LIMITED TO NOT MORE THAN 80 VOLTS UPON
RAPID SHUT-DOWN INITIATION PER 690.12.
·PV SYSTEM SHALL CONTAIN OR INTERACT WITH DEVICES CAPABLE OF DETECTING AND
INTERRUPTING ARCING FAULTS WITHIN THE SYSTEM PER 690.11.
·BURIED CONDUCTORS SHALL BE BURIED TO THE MINIMUM DEPTH SPECIFIED IN ART. 300.5
FOR CIRCUITS 1000V AND UNDER AND ART. 300.50 FOR CIRCUITS ABOVE 1000V.
·SPACES ABOUT ELECTRICAL EQUIPMENT 1000V AND UNDER SHALL COMPLY WITH 110.26
AND SPACES ABOUT ELECTRICAL ENCLOSURES ABOUT EQUIPMENT ABOVE 1000V SHALL
COMPLY WITH 110.34.
·REFER TO THE CONDUCTOR SCHEDULE FOR THE TYPE OF CONDUCTORS TO BE USED FOR
THE LISTED CIRCUITS.
·PV WIRE SHALL BE SECURED USING NON-METALLIC UV-RATED TIE WRAPS.
·ALL LINE SIDE AND LOAD SIDE TERMINATIONS OF ALUMINUM AND COPPER CONDUCTORS
SHALL BE MADE WITH HIGH PRESS CRIMP LUGS ON BUSSING UNLESS OTHERWISE NOTED.
·ALL TERMINATIONS OF ALUMINUM CONDUCTORS SHALL BE PROPERLY INSTALLED WITH
BEST PRACTICE PROCEDURES THAT INCLUDE BUT NOT LIMITED TO: USE OF TERMINATION
EQUIPMENT RATED FOR ALUMINUM AT THE CONDUCTOR TEMPERATURE, CURRENT, AND
VOLTAGE; ALLOWANCE FOR MOVEMENT DUE TO THERMAL EXPANSION/CONTRACTION;
PROPER COATING OF EXPOSED ALUMINUM WITH ANTI-OXIDIZATION COMPOUND; USE OF
CALIBRATED DEVICES TO TORQUE AND MARK TERMINALS TO REQUIRED SETTINGS.
·AT MULTIPLE INVERTERS OUTPUT COMBINER PANEL, TOTAL RATING OF ALL OVERCURRENT
DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, THE MAIN OVERCURRENT
DEVICE MAY BE EXCLUDED ACCORDING TO NEC 705.12 (B)(3)(3).
GROUNDING NOTES
·GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND
GROUNDING DEVICES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE.
·PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM NEC TABLE
250.122.
·METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED
GROUNDED IN ACCORD WITH 250.134 AND 250.136.
·EACH MODULE WILL BE GROUNDED USING THE HARDWARE INTEGRATED GROUNDING PINS
OR OTHER MEANS APPROVED BY THE MODULE MANUFACTURE AND AHJ.
·THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE
REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER
MODULE.
··GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR
MARKED GREEN IF #4 AWG OR LARGER [NEC 250.119(A)]
·THE AC & DC GEC SHALL BE CONTINUOUS FROM THE INVERTER GROUND BUSBAR TO THE
MAIN ELECTRICAL SERVICE GROUNDING ELECTRODE SYSTEM. THE DC GEC SHALL BE
ATTACHED TO THE GROUND ELECTRODE USING AN IRREVERSIBLE MEANS AS CALLED OUT
IN ART 250.64 AND 690.47.
·PV INVERTER CONTAINS AN INTEGRATED GFDI CIRCUIT. DO NOT BOND THE GROUNDED DC
CONDUCTOR TO GROUND EXCEPT THROUGH THE INVERTER GFDI.
·ALL EXPOSED METAL PARTS (MODULE FRAMES, RAIL, PIPE, BOXES, ETC) SHALL BE
GROUNDED USING TIN-PLATED COPPER LAY-IN LUGS OR GROUNDING CLIPS LISTED FOR
THE PURPOSE. RAIL CLAMPS SHALL BE MADE ELECTRICALLY CONTINUOUS WITH ATTACHED
RAIL.
·RACKING SYSTEMS SHALL BE BONDED PER MANUFACTURER'S UL 2703 INSTRUCTIONS.
·MIN #10 BARE COPPER EGC AT SOURCE CIRCUITS SHALL BE ROUTED SECURELY TO
MOUNTING HARDWARE IN A MANNER THAT PROTECTS FROM PHYSICAL HARM. #6 BARE
COPPER EGC FOR AREAS SUBJECT TO PHYSICAL DAMAGE.
·MODULE FRAMES SHALL BE GROUNDED AT THE LISTED LOCATION PROVIDED BY THE
MANUFACTURER OR USING LISTED THIRD-PARTY HARDWARE ONLY IF SPECIFICALLY
REFERRED TO IN MANUFACTURER'S INSTRUCTIONS PER UL 1703.INSTALLER SHALL COMPLY
WITH MANUFACTURER GROUND IN BONDING REQUIREMENTS
·BOTH ENDS OF ALL METALLIC CONDUIT CONTAINING GROUNDING ELECTRODE
CONDUCTORS SHALL BE BONDED PER ART 250.64(E).
·GROUNDING ELECTRODE CONDUCTOR TO BE BONDED TO (E) GROUNDING ELECTRODE PER
ART 250.68.
·DC GROUNDING ELECTRODE CONDUCTOR SIZED PER ART 690.47. AC GROUNDING
ELECTRODE CONDUCTOR PER 250.66.
·MAIN BONDING JUMPERS AND GROUNDED CONDUCTORS (NEUTRALS) SHALL BE SIZED PER
250.102 UNLESS OTHERWISE ALLOWED TO BE SIZED PER 705.28(C).
·INCREASES IN DC EQUIPMENT GROUNDING CONDUCTOR SIZE TO ADDRESS VOLTAGE
CONSIDERATIONS SHALL NOT BE REQUIRED PER ART 690.45.
·INCREASES IN AC EQUIPMENT GROUNDING CONDUCTOR SIZE TO ADDRESS VOLTAGE
CONSIDERATIONS SHALL BE REQUIRED PER 250.122(B).
·INSTALLATION SHALL COMPLY WITH ART 250.52, 250.53.
·CIRCUITS OVER 250V SHALL COMPLY WITH ART. 250.97, 250.92(B).
SITE TEMPERATURES
MAX TEMP [°C]: 38
MIN TEMP [°C]: -2
NO CONDUCTOR
PERMITTED IN SHADED
AREA
A SCE METERING NOTES
NTS
GENERATOR
CONDUCTORS
CONNECT ON LOAD
TERMINALS
UTILITY
CONDUCTORS
CONNECT ON LINE
TERMINALS
SELF-CONTAINED ENCLOSURE
COMBINATION CURRENT
TRANSFORMER AND METER CAN
1.WIRING OF A NGO METER SOCKET FOR VIRTUAL NET METERING PROJECTS , THE GENERATOR SHALL BE
CONNECTED TO THE LOAD SIDE OF THE NGO SOCKET.
2.THE HORIZONTAL CLEARANCE FROM THE CENTERLINE OF THE METER TO THE NEAREST SIDE WALL OR
OTHER OBSTRUCTION SHALL BE 10" MINIMUM. A HORIZONTAL CLEARANCE FROM THE EDGE OF THE
METER PANEL TO THE EDGE OF A WINDOW OR DOORWAY (INCLUDING SLIDING GLASS DOORS) SHALL BE
10" MINIMUM.
3.A CLEAR AND LEVEL WORKING SURFACE SHALL BE PROVIDED WITH A THE MINIMUM WIDTH OF THE
WORKSPACE SHALL BE 36 AND A MINIMUM DEPTH OF 36".
4.THE MINIMUM HEIGHT OF THE METER SHALL BE 4' AND MAXIMUM HEIGHT SHALL NOT EXCEED 6'-3"
MEASURED FROM STANDING SURFACE TO CENTERLINE OF METER SOCKET.
4.1.THE MINIMUM HEIGHT CAN BE REDUCED TO 3' IF LOCATED IN A METER ROOM.
5.DRAWING IS FOR WIRE REFERENCE ONLY AND IS NOT REFLECTIVE OF ACTUAL WIRE PENETRATIONS.
5 5
REMOVABLE TEST
PERCH
5
5
℄
℄REFER TO DC
STRING SCHEDULES
FOR FOR STRING
LENGTHS AND
OPTIMIZER
QUANTITY
B STRING WIRING - SINGLE OPTIMIZER (TYP.)
NTS
NOTE:
1.NEGATIVE TOO RUN ALONG SIDE THE POSITIVE WIRE. ALL WIRES MUST BE
SECURED TO UNDERSIDE OF THE RACKING AND MODULES USING SUNRUN
APPROVED METHODS AND MATERIALS WITH APPROPRIATE UV AND
ENVIRONMENTAL RATINGS.
2.CONDUIT TRANSITIONS SHALL BE MADE UNDER ARRAY.
3.INSTALL STRING LABELS ON BOTH ENDS OF HOMERUNS USING LABELS
SUITABLE FOR THE ENVIRONMENT.
4.FIELD INSTALLED CONNECTOR, 1000VDC, MATING MUST MATCH
MANUFACTURES RECOMMENDATIONS (TYP. TWO PER STRING)
5.TOTAL CIRCUIT LENGTH SHALL NOT EXCEED MANUFACTURE SPECIFICATIONS
6.FREE-AIR PV WIRE TO MATCH GAUGE OF DC-X.X CIRCUIT LOCATED ON DC
WIRE SCHEDULES.
4
4
3
3
2 1
(N) SOLAREGDE
OPTIMIZER
(N) PV MODULE
5
6
150' MAX DISTANCE
FOR WIRELESS
OPTIONAL THIRD BATTERY
(N) J-BOX WITH 3 OR 4 PORT POLARIS LUG OR
EQUIV.
(N) SOLAREDGE ENERGY BANK
BAT-10K1P, WALL MOUNTED OR
USING MANUFACTURES FLOOR
STAND KIT (IAC-RBAT-FLRSTD-01)
(N) SOLAREDGE HOME HUB INVERTER
MC-4
CONNECTORS TO
BATTERY
CONNECTION
UNIT
ES-1
ES-2
#CONDUIT CONDUCTOR GROUND
ES-1
FLOOR STAND INTERNAL
CHANNEL OR 3/4" EMT OR
EQUIV.
(2) 10 AWG PV WIRE (1) 10 AWG THHN/THWN-2
ES-2 3/4" EMT OR EQUIV.(2) 8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2
SOLAREDGE BESS WIRING
NTSC
OPTIMIZER A:
MAKE/MODEL: SOLAREDGE U650
MAX INPUT POWER [W]: 650
MAX INPUT Voc [V]: 60
MAX INPUT Isc [A]: 15
OUTPUT CURRENT [A]: 15
MODULE A:
MAKE/MODEL: QCELLS NORTH AMERICA Q.PEAK DUO BLK ML-G10.C+ 410
POWER [W]: 410
Voc [V]: 45.37
Isc [A]: 11.2
Vmp [V]: 37.64
Imp [A]: 10.89
Voc coeff. [%/degC]: -0.27%
Isc coeff. [%/degC]: 0.04%
# IN SERIES: 1
Vmax CALCULATION: 48.7 VDC = 1 X ( 45.37 VDC - ( 25 - (-2)°C X ( 45.37 X -0.0027 ) V/°C )
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
ELECTRICAL NOTES
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
E500
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#ESTAMP
WILSHIRE MINNIE
1209 E WILSHIRE AVE UNIT# MTR02
1209 3/4 E WILSHIRE AVE UNIT# ELE01
1221 E WILSHIRE AVE UNIT# MTR02
1221 3/4 E WILSHIRE AVE UNIT# ELE01
1229 E WILSHIRE AVE UNIT# MTR02
1229 3/4 E WILSHIRE AVE UNIT# ELE01
1233 E WILSHIRE AVE UNIT# MTR01
1401 S MINNIE ST UNIT# MTR01
1403 S MINNIE ST UNIT# MTR01
1425 S MINNIE ST UNIT# MTR01
APN: 014-251-49 / 014-251-50
DEVELOPER: C&C DEVELOPMENT
##KEYED NOTES#EQUIPMENT NOTES#
#
COMMUNICATION
CAT5E 600V RATED SHIELDED CABLE.
INSTALLER SHALL FOLLOW
MANUFACTURES RECOMMENDATION FOR
WIRE SIZING BASED ON LENGTH.
CIRCUIT IDENTIFIER
EQUIPMENT INDEX
EQUIPMENT TYPE
SYSTEM IDENTIFIER X INDICATES LETTERS
# INDICATES NUMBERS
XX-#.#
SYSTEM SUMMARY
38.00 ACKW | 54.12 DCKW | 50.43 CECKW
38.00 BESS ACKW | 116.40 BESS KWH
TOTAL FAULT CURRENTS
UTILITY: 42,000A | GENERATORS: 296A
DESCRIPTION OF OPERATION (DOO)
1.INVERTERS WITH ESS ARE CERTIFIED TO UL 1741 PCS CRD AND WILL HAVE
EXPORT-ONLY MODES ENABLED. THEY WILL UTILIZE EXCESS PV POWER TO CHARGE
THE BATTERIES AND THE BATTERIES WILL DISCHARGE DURING SET HOURS.
2.THE PRODUCER'S STORAGE DEVICE(S) WILL NOT CONSUME POWER FROM THE
DISTRIBUTION PROVIDER'S DISTRIBUTION SYSTEM AT ANY TIME.
3.GRID EXPORT IS ALLOWED THROUGH NEMV METER.
4.DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT
FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO
THE ACCEPTABLE MEASURE.
+-
18
14
1
13
14
ES-1
(3
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
1
.
1
.
A
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
ST
R
-
1
.
1
.
B
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
ST
R
-
1
.
1
.
C
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
14
ES-2
DC-1.1.1
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4A
A-B
60A
INV-1.1
+-
18
14
1
13
14
ES-1
(3
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
1
.
2
.
A
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
ST
R
-
1
.
2
.
B
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
ST
R
-
1
.
2
.
C
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
ES-2
DC-1.2.2
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4A
A-B
60A
INV-1.2
+-
18
14
1
13
14
ES-1
(3
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
1
.
3
.
A
-
(
1
2
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
2
)
U
6
5
0
O
P
T
S
.
ST
R
-
1
.
3
.
B
-
(
1
2
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
2
)
U
6
5
0
O
P
T
S
.
ES-2
DC-1.3.3
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4B
A-B
40A
INV-1.3
+-
18
14
1
13
14
ES-1
(3
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
1
.
4
.
A
-
(
1
2
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
2
)
U
6
5
0
O
P
T
S
.
ST
R
-
1
.
4
.
B
-
(
1
2
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
2
)
U
6
5
0
O
P
T
S
.
ES-2
DC-1.4.4
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4B
A-B
40A
INV-1.4
6
LC-1.1
6
8
5
(N) ACDS-2 SYSTEM AC DISCONNECT
SWITCH,, SQUARE D, VHU364R, 600V RATED,
240V OPERATIONAL, 200A, 3 POLE,
NON-FUSIBLE, NEMA 3R. VISIBLE, LOCKABLE.
SEE REFERENCE SHEETS FOR KAIC RATING.
AC-1.2
M9
4
(N) SCE PV PRODUCTION METER SOCKET
ADDRESS: 1209 E WILSHIRE AVE UNIT#
MTR02, COOPER B-LINE, 124TB, 200 A,
SERVICE 1 PHASE 3 WIRE 120/240 VAC, NEMA
3R
AC-1.2
10
3
(N) ACDS-1 SYSTEM UTILITY AC DISCONNECT
SWITCH, SQUARE D, VH224NR, 240V RATED,
240V OPERATIONAL, 200A, 2 POLE, FUSIBLE,
NEMA 3R, OR EQUIVALENT ON THE UTILITIES
APPROVED LIST. VISIBLE, LOCKABLE.
CLASS J FUSE, 200KAIC RATING.
A-B
200AAC-1.1
M
M
M
M
M FACILITY
LOADS
(E) TENANT
METERS (TYP.)
(N) POLARIS
BLOCK
-
A
11101
15
200A
POI-1 DC STRING SCHEDULE
STR-A STR-B STR-C
TAG DESTINATION CIRCUIT LENGTH ²VD%MODULE
WATTAGE
MODULE QTY OPTIMIZER MIN/MAX
MODULES
CIRCUIT LENGTH ²VD%MODULE
WATTAGE
MODULE QTY OPTIMIZER MIN/MAX
MODULES
CIRCUIT LENGTH ²VD%MODULE
WATTAGE
MODULE QTY OPTIMIZER MIN/MAX
MODULES
DC-1.1.1 INV-1.1 80 0.48%410 14 U650 8 / 16¹85 0.48%410 14 U650 8 / 16¹65 0.39%410 14 U650 8 / 16¹
DC-1.2.2 INV-1.2 100 0.59%410 14 U650 8 / 16¹80 0.45%410 14 U650 8 / 16¹75 0.45%410 14 U650 8 / 16¹
DC-1.3.3 INV-1.3 150 1.22%410 12 U650 8 / 16¹155 1.18%410 12 U650 8 / 16¹------------
DC-1.4.4 INV-1.4 155 1.26%410 12 U650 8 / 16¹135 1.03%410 12 U650 8 / 16¹------------
¹ MAXIMUM STRING LENGTH IS USING MANUFACTURES EXCEPTION
² LENGTHS ARE ESTIMATED FOR CALCULATIONS, CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS AND TAKEOFFS
³ WHERE EXPOSED TO PHYSICAL DAMAGE #6 TO BE USED PER NEC 250.120(C)
⁴ AFC VALUES ARE CALCULATED BASED ON WIRE LENGTHS. LENGTHS SHOULD REMAIN GREATER THAN OR EQUAL TO THE LENGTH LISTED IN THE TABLE.
A INTERCONNECTION LOCATION
NTS1209 E WILSHIRE AVE UNIT# MTR02
POI-1 DC WIRE SCHEDULE
TAG WIRE GAUGE CONDUCTOR
JACKET
MAX ISC 1.25 X MAX
CIRCUIT AMPS
CIRCUIT FUSE
RATING
CCC PER
CONDUIT
MAX AMBIENT
TEMP (C)
C.O.U TEMP.
DERATE
C.O.U CONDUIT
FILL DERATE
75°C AMPACITY COMPLIES WITH
690.8(B)(1)
90°C AMPACITY
WITH C.O.U
COMPLIES WITH
690.8(B)(2)
FAULT CURRENT
FROM PARALLEL
STRINGS
COMPLIES WITH
690.9(A)
GROUNDING
PER CONDUIT
GROUNDING ³EMT RMC PVC 40 PVC 80
DC-1.1.1 CU #8 THWN2 15 18.75 NONE 6 38 91%80%50 YES 40.0 YES 30 YES 3 CU #10 1"1"1"1 1/4"
DC-1.2.2 CU #8 THWN2 15 18.75 NONE 6 38 91%80%50 YES 40.0 YES 30 YES 3 CU #10 1"1"1"1 1/4"
DC-1.3.3 CU #10 THWN2 15 18.75 NONE 4 38 91%80%35 YES 29.1 YES 15 YES 2 CU #10 3/4"3/4"3/4"3/4"
DC-1.4.4 CU #10 THWN2 15 18.75 NONE 4 38 91%80%35 YES 29.1 YES 15 YES 2 CU #10 3/4"3/4"3/4"3/4"
LINE SIDE TAP VIA POLARIS TAPS
(POINT OF INTERCONNECTION)
SCE METER
UTILITY METER REFERENCE NUMBER:
222012-828760
SCE UTILITY GRID 240V, 1ø,3W
ENTRENCHED
~20' PVC-80
EMT
EMT
ENTRENCHED
~20' PVC-80
EMT
EMT
ENTRENCHED
~23.5' PVC-80
EMT
EMT
ENTRENCHED
~23.5' PVC-80
EMT
EMT
14 14 14
ENTRENCHED
~20' PVC-80
EMT
ENTRENCHED
~6' PVC-80
EMT ENTRENCHED
~23.5' PVC-80
EMT
ENTRENCHED
~23.5' PVC-80
EMT
ENTRENCHED
~20' PVC-80
EMT
EMT EMT EMT
EMT
1209 E WILSHIRE AVE
E401
G
BLDG
1209
GEC
E401
G
BLDG
1213
GEC
E401
G
BLDG
1201
GEC
E401
G
BLDG
1201
GEC
1209 E WILSHIRE AVE 1213 E WILSHIRE AVE 1201 E WILSHIRE AVE 1201 E WILSHIRE AVE
PARKING STRUCTURE
NEW ADDRESS TO BE
ASSIGNED
1. PV MODULES (132) QCELLS NORTH
AMERICA Q.PEAK DUO BLK ML-G10.C+ 410
2. (132) SOLAREDGE DC OPTIMIZER U650
3. DC PV AND ESS CONNECTION UNIT W/
INTEGRAL LOAD BREAK DISCONNECT
4. 4A: (2) SOLAREDGE SE11400H-US HOME
HUB [240V] [SI1-SB] [CRD-PCS NEM],
11,400W, 240VAC, 1ø, 3W
4B: (2) SOLAREDGE SE7600H-US HOME
HUB [240V] [SI1-SB] [CRD-PCS NEM],
7,600W, 240VAC, 1ø, 3W
5. (N) REVENUE GRADE METER, 1ø,
INTERGRATED RGM, W/ NOT REQUIRED
CTS
6. (1) LOAD CENTER, 200A, 1ø, MIN.240VAC,
MIN. 10KAIC, NEMA 3R
7. NOT USED
8.(N) ACDS-2 SYSTEM AC DISCONNECT
SWITCH, SQUARE D, VHU364R, 600V
RATED, 240V OPERATIONAL, 200A, 3 POLE,
NON-FUSIBLE, NEMA 3R. SEE REFERENCE
SHEETS FOR KAIC RATING.
9. (N) SCE PV PRODUCTION METER SOCKET
ADDRESS: 1209 E WILSHIRE AVE UNIT#
MTR02, COOPER B-LINE, 124TB, 200A,
SERVICE: 1 PHASE 3 WIRE 120/240 VAC, #
JAW, NEMA 3R, EUSERC: 305
10. (N) ACDS-1 SYSTEM UTILITY AC
DISCONNECT SWITCH, SQUARE D,
VH224NR, 240V RATED, 240V
OPERATIONAL, 200A, 2 POLE, FUSIBLE,
NEMA 3R, OR EQUIVALENT ON THE
UTILITIES APPROVED LIST.
CLASS J FUSE, 200KAIC RATING.
11. (E) MAIN SERVICE EQUIPMENT: 1 PHASE 3
WIRE 120/240 VAC, 200A
12. (N) CELL-B-R05-US-S-S2 CELL CARD
13. (12) SOLAREDGE BAT-10K1P BATTERIES,
9.70KWH, 5,000DCW, NEMA 3R, MOUNTED
TO WALL OR MANUFACTURER FLOOR
MOUNT KIT
14. (N) DC DISCONNECT SWITCH
15. (N) POLARIS BLOCKS
16. NOT USED
1.(E) MAIN SWITCHGEAR AND (N) POINT OF
AC INTERCONNECTION. ALL
CONNECTIONS MADE INSIDE (E)
SWITCHGEAR AT OTHER THAN CIRCUIT
BREAKERS OR FUSED SWITCHES LISTED
FOR USE WITH THAT SWITCHGEAR SHALL
BE PERFORMED FOLLOWING
MANUFACTURERS INSTRUCTIONS OR BE
RE-LISTED BY A NRTL. ALL TERMINATIONS
OF ALUMINUM CONDUCTORS SHALL BE
WITH HIGH PRESS CRIMP LUGS ONLY.
WARNING LABEL DETAIL 1/E800
2.(E) UTILITY TENANT LOAD METER. UTILITY
REFERENCE METER NUMBER:
222012-828760
3.(N) PV SYSTEM UTILITY AC DISCONNECT
'ACDS-1'. WARNING LABEL DETAIL 1/E810
4.(N) UTILITY BIDIRECTIONAL KWH METER.
WARNING LABEL DETAIL 1/E810
5.(N) PV SYSTEM MAINTENANCE AC
DISCONNECT 'ACDS-2'. WARNING LABEL
DETAIL 2/E800 & 1/E810
6.NOT USED
7.(N) GRID-INTERACTIVE PV INVERTER
LISTED TO UL 1741 WITH GROUND FAULT
DETECTION & INTERRUPTION. WARNING
LABEL DETAIL 15/E800.
8.NOT USED
9.NOT USED
10.FOR SUPPLY SIDE CONNECTIONS, A
PLAQUE SHALL BE INSTALLED AT THE
MAIN SERVICE DISCONNECTING DEVICE
AND THE PV SYSTEM UTILITY AC
DISCONNECT INDICATING THE LOCATION
OF THE RESPECTIVE SERVICE
DISCONNECT. WARNING LABEL DETAIL
1/E800 & 1/E810
11.NOT USED
12.CONDUCTORS RUN IN PARALLEL SHALL
BE INSTALLED PER ART 310.4/310.10(G)
AND 250.122 (F).
13.NOT USED
14.NEW PULL/JUNCTION BOXES. PROVIDE
SERVICE LOOP IN ALL DC BRANCH
CONDUCTORS SOURCED FROM
ROOFTOPS, MIN LOOP RADIUS = 12X
CONDUCTOR DIAMETER.
15.NOT USED
16.(N) INVERTER INTERNAL DC DISCONNECT
SWITCH(ES). WARNING LABEL DETAIL
3/E800
17.NOT USED
18.(N) PV MODULE LISTED TO UL 1703.
19.EXTRA MODULES THAT ARE UNABLE TO
BE PAIRED WILL HAVE THEIR OWN
OPTIMIZER.
20.(N) COMMUNICATION WIRING TO FOLLOW
MANUFACTURING SPECIFICATIONS.
21.DURING UTILITY GRID OUTAGE THE PV
GENERATION AND BESS WILL
DISCONNECT FROM THE GRID AND
REMAIN DISCONNECTED UNTIL GRID
VOLTAGE IS RESTORED TO THE
ACCEPTED MEASURE.
22.BATTERY AC OUTPUT POWER IS LIMITED
TO THE CORRESPONDING INVERTER OR
TOTAL BATTERIES CONNECTED TO A
SINGLE INVERTER,WHICHEVER IS LOWER.
23.BATTERIES SHOULD NOT BE INSTALLED IN
DIRECT SUNLIGHT OR LOCATIONS
SUBJECTED TO WATER SPRAY.
SPRINKLERS SHOULD BE DIVERTED
WHEN NECESSARY.
24.BATTERIES CAN COMMUNICATE
WIRELESSLY OR VIA RS-485 TO INVERTER.
BATTERIES WITHIN 150' (IDEALLY 50') OF
RESPECTIVE INVERTER CAN USE
WIRELESS COMMUNICATIONS VIA SEDG
HOME NETWORK CARD.
25.COMBINED PV AND BESS OUTPUT POWER
IS LIMITED TO THE INVERTER AC RATING.
26.SOLAREDGE ENERGY BANK MAY BE
WALL, FLOOR, OR PAD MOUNTED
INDIVIDUALLY OR IN GROUPS OF (2), (3),
OR (4) UTILIZING THE SOLAREDGE FLOOR
MOUNT STAND. ENERGY BANK MEETS
THE UNIT LEVEL PERFORMANCE
CRITERIA OF UL 9540A, ALLOWING
ENERGY BANK TO BE STACKED FRONT TO
BACK AS LONG AS THE CLEARANCE
REQUIREMENTS ARE FOLLOWED TO
ALLOW FOR AIR FLOW AROUND THE
UNITS.
RMC ONLY
E500
D
E500
D
E500
D
E500
D
AHJ NOTES:
1.FUSED AC DISCONNECTS MUST BE SUSE RATED WITH A MAIN BONDING JUMPER
INSTALLED. CEC 230.82(6)
2.THE "GROUND" WIRE OF FUSED AC DISCONNECTS IS A GROUNDING ELECTRODE
CONDUCTOR TO BE BONDED TO THE GEC SYSTEM OF THE BUILDING
3.DISCONNECTS MUST BE WITHIN RMC TO THE POI. THE DISCONNECT AND THE
SUPPLY-SIDE POI MUST BE SEALED BY SCE. THIS IS CITY POLICY FOR SE
CONDUCTORS TO MINIMIZE POWER THEFT AND DAMAGE.
TO
GEC
EGCRMC ONLY
RMC ONLY
UTILITY TERMINATION
WEATHERHEAD - UTILITY
TERMINATION POINT
SCE CECTION
CUSTOMER
SECTION
DISTANCE FROM FUSED
ACD TO POI ~ 5 FT
POI-1 AC WIRE SCHEDULE
LABEL DESTINATION NOMINAL VAC LINE SELECTION FLA FLAX1.25 OCPD PHASE
CONDUCTOR
NEUTRAL
CONDUCTOR
GROUNDING
CONDUCTOR
CONDUCTORS PER
PHASE
CONDUIT QTY 75°C AMPS 90°C AMPS 90°C AMPS W/
C.O.U
C.O.U TEMP
DERATE
C.O.U CONDUIT
FILL
CIRCUIT LENGTH ²SEGMENT VD%DC/AC RATIO AFC START AFC END ⁴EMT IMC PVC 40 PVC 80
INV-1.1 LC-1.1 240 A-B 47.5 59.4 60 CU #6 CU #10 CU #10 1 1 65 75 68.3 91%100%75 1.40%151.1%5,810 2,326 3/4"3/4"3/4"3/4"
INV-1.2 LC-1.1 240 A-B 47.5 59.4 60 CU #6 CU #10 CU #10 1 1 65 75 68.3 91%100%75 1.40%151.1%5,810 2,326 3/4"3/4"3/4"3/4"
INV-1.3 LC-1.1 240 A-B 31.7 39.6 40 CU #8 CU #10 CU #10 1 1 50 55 50.1 91%100%75 1.48%129.5%5,810 1,744 1/2"1/2"3/4"3/4"
INV-1.4 LC-1.1 240 A-B 31.7 39.6 40 CU #8 CU #10 CU #10 1 1 50 55 50.1 91%100%75 1.48%129.5%5,810 1,744 1/2"1/2"3/4"3/4"
LC-1.1 AC-1.2 240 A-B 158.3 197.9 200 CU #3/0 CU #6 CU #6 1 1 200 225 204.8 91%100%19 0.19%--6,258 5,810 1 1/2"1 1/4"1 1/2"1 1/2"
AC-1.2 AC-1.1 240 A-B 158.3 197.9 200 CU #3/0 CU #6 CU #6 1 1 200 225 204.8 91%100%10 0.10%--6,523 6,258 1 1/2"1 1/4"1 1/2"1 1/2"
AC-1.1 POI-1.1 240 A-B 158.3 197.9 200 CU #3/0 CU #3/0 CU #4 1 1 200 225 204.8 91%100%5 0.05%--42,000 36,964 2"1 1/2"2"2"
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
POI-1 ONE LINE
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
E600
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#ESTAMP
WILSHIRE MINNIE
1209 E WILSHIRE AVE UNIT# MTR02
1209 3/4 E WILSHIRE AVE UNIT# ELE01
APN: 014-251-49
DEVELOPER:
C&C DEVELOPMENT
##KEYED NOTES#EQUIPMENT NOTES#
#
COMMUNICATION
CAT5E 600V RATED SHIELDED CABLE.
INSTALLER SHALL FOLLOW
MANUFACTURES RECOMMENDATION FOR
WIRE SIZING BASED ON LENGTH.
CIRCUIT IDENTIFIER
EQUIPMENT INDEX
EQUIPMENT TYPE
SYSTEM IDENTIFIER X INDICATES LETTERS
# INDICATES NUMBERS
XX-#.#
SYSTEM SUMMARY
34.20 ACKW | 47.56 DCKW | 44.32 CECKW
34.20 BESS ACKW | 87.30 BESS KWH
TOTAL FAULT CURRENTS
UTILITY: 42,000A | GENERATORS: 222A
DESCRIPTION OF OPERATION (DOO)
1.INVERTERS WITH ESS ARE CERTIFIED TO UL 1741 PCS CRD AND WILL HAVE
EXPORT-ONLY MODES ENABLED. THEY WILL UTILIZE EXCESS PV POWER TO CHARGE
THE BATTERIES AND THE BATTERIES WILL DISCHARGE DURING SET HOURS.
2.THE PRODUCER'S STORAGE DEVICE(S) WILL NOT CONSUME POWER FROM THE
DISTRIBUTION PROVIDER'S DISTRIBUTION SYSTEM AT ANY TIME.
3.GRID EXPORT IS ALLOWED THROUGH NEMV METER.
4.DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT
FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO
THE ACCEPTABLE MEASURE.
+-
18
14
1
13
14
ES-1
(3
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
2
.
1
.
A
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
ST
R
-
2
.
1
.
B
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
ST
R
-
2
.
1
.
C
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
14
ES-2
DC-2.1.1
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4
A-B
60A
INV-2.1
+-
18
14
1
13
14
ES-1
(3
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
2
.
2
.
A
-
(
1
3
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
3
)
U
6
5
0
O
P
T
S
.
ST
R
-
2
.
2
.
B
-
(
1
2
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
2
)
U
6
5
0
O
P
T
S
.
ST
R
-
2
.
2
.
C
-
(
1
2
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
2
)
U
6
5
0
O
P
T
S
.
14
ES-2
DC-2.2.2
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4
A-B
60A
INV-2.2
+-
18
14
1
13
14
ES-1
(3
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
2
.
3
.
A
-
(
1
3
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
3
)
U
6
5
0
O
P
T
S
.
ST
R
-
2
.
3
.
B
-
(
1
2
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
2
)
U
6
5
0
O
P
T
S
.
ST
R
-
2
.
3
.
C
-
(
1
2
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
2
)
U
6
5
0
O
P
T
S
.
14
ES-2
DC-2.3.3
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4
A-B
60A
INV-2.3
6
LC-2.1
6
8
5
(N) ACDS-2 SYSTEM AC DISCONNECT
SWITCH,, SQUARE D, VHU364R, 600V RATED,
240V OPERATIONAL, 200A, 3 POLE,
NON-FUSIBLE, NEMA 3R. VISIBLE, LOCKABLE.
SEE REFERENCE SHEETS FOR KAIC RATING.
AC-2.2
M9
4
(N) SCE PV PRODUCTION METER SOCKET
ADDRESS: 1221 E WILSHIRE AVE UNIT#
MTR02, COOPER B-LINE, 124TB, 200 A,
SERVICE 1 PHASE 3 WIRE 120/240 VAC, NEMA
3R
AC-2.2
10
3
(N) ACDS-1 SYSTEM UTILITY AC DISCONNECT
SWITCH, SQUARE D, VH224NR, 240V RATED,
240V OPERATIONAL, 200A, 2 POLE, FUSIBLE,
NEMA 3R, OR EQUIVALENT ON THE UTILITIES
APPROVED LIST. VISIBLE, LOCKABLE.
CLASS J FUSE, 200KAIC RATING.
A-B
200AAC-2.1
A INTERCONNECTION LOCATION
NTS1221 E WILSHIRE AVE UNIT# MTR02
POI-2 DC STRING SCHEDULE
STR-A STR-B STR-C
TAG DESTINATION CIRCUIT LENGTH ²VD%MODULE
WATTAGE
MODULE QTY OPTIMIZER MIN/MAX
MODULES
CIRCUIT LENGTH ²VD%MODULE
WATTAGE
MODULE QTY OPTIMIZER MIN/MAX
MODULES
CIRCUIT LENGTH ²VD%MODULE
WATTAGE
MODULE QTY OPTIMIZER MIN/MAX
MODULES
DC-2.1.1 INV-2.1 50 0.30%410 14 U650 8 / 16¹90 0.50%410 14 U650 8 / 16¹65 0.39%410 14 U650 8 / 16¹
DC-2.2.2 INV-2.2 80 0.44%410 13 U650 8 / 16¹75 0.36%410 12 U650 8 / 16¹120 0.61%410 12 U650 8 / 16¹
DC-2.3.3 INV-2.3 130 0.72%410 13 U650 8 / 16¹95 0.46%410 12 U650 8 / 16¹115 0.59%410 12 U650 8 / 16¹
¹ MAXIMUM STRING LENGTH IS USING MANUFACTURES EXCEPTION
² LENGTHS ARE ESTIMATED FOR CALCULATIONS, CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS AND TAKEOFFS
³ WHERE EXPOSED TO PHYSICAL DAMAGE #6 TO BE USED PER NEC 250.120(C)
⁴ AFC VALUES ARE CALCULATED BASED ON WIRE LENGTHS. LENGTHS SHOULD REMAIN GREATER THAN OR EQUAL TO THE LENGTH LISTED IN THE TABLE.
POI-2 DC WIRE SCHEDULE
TAG WIRE GAUGE CONDUCTOR
JACKET
MAX ISC 1.25 X MAX
CIRCUIT AMPS
CIRCUIT FUSE
RATING
CCC PER
CONDUIT
MAX AMBIENT
TEMP (C)
C.O.U TEMP.
DERATE
C.O.U CONDUIT
FILL DERATE
75°C AMPACITY COMPLIES WITH
690.8(B)(1)
90°C AMPACITY
WITH C.O.U
COMPLIES WITH
690.8(B)(2)
FAULT CURRENT
FROM PARALLEL
STRINGS
COMPLIES WITH
690.9(A)
GROUNDING
PER CONDUIT
GROUNDING ³EMT RMC PVC 40 PVC 80
DC-2.1.1 CU #8 THWN2 15 18.75 NONE 6 38 91%80%50 YES 40.0 YES 30 YES 3 CU #10 1"1"1"1 1/4"
DC-2.2.2 CU #8 THWN2 15 18.75 NONE 6 38 91%80%50 YES 40.0 YES 30 YES 3 CU #10 1"1"1"1 1/4"
DC-2.3.3 CU #8 THWN2 15 18.75 NONE 6 38 91%80%50 YES 40.0 YES 30 YES 3 CU #10 1"1"1"1 1/4"
LINE SIDE TAP VIA POLARIS TAPS
(POINT OF INTERCONNECTION)
SCE METER
1. PV MODULES (116) QCELLS NORTH
AMERICA Q.PEAK DUO BLK ML-G10.C+ 410
2. (116) SOLAREDGE DC OPTIMIZER U650
3. DC PV AND ESS CONNECTION UNIT W/
INTEGRAL LOAD BREAK DISCONNECT
4. (3) SOLAREDGE SE11400H-US HOME HUB
[240V] [SI1-SB] [CRD-PCS NEM], 11,400W,
240VAC, 1ø, 3W
5. (N) REVENUE GRADE METER, 1ø,
INTERGRATED RGM, W/ NOT REQUIRED
CTS
6. (1) LOAD CENTER, 200A, 1ø, MIN.240VAC,
MIN. 10KAIC, NEMA 3R
7. NOT USED
8.(N) ACDS-2 SYSTEM AC DISCONNECT
SWITCH, SQUARE D, VHU364R, 600V
RATED, 240V OPERATIONAL, 200A, 3 POLE,
NON-FUSIBLE, NEMA 3R. SEE REFERENCE
SHEETS FOR KAIC RATING.
9. (N) SCE PV PRODUCTION METER SOCKET
ADDRESS: 1221 E WILSHIRE AVE UNIT#
MTR02, COOPER B-LINE, 124TB, 200A,
SERVICE: 1 PHASE 3 WIRE 120/240 VAC, #
JAW, NEMA 3R, EUSERC: 305
10. (N) ACDS-1 SYSTEM UTILITY AC
DISCONNECT SWITCH, SQUARE D,
VH224NR, 240V RATED, 240V
OPERATIONAL, 200A, 2 POLE, FUSIBLE,
NEMA 3R, OR EQUIVALENT ON THE
UTILITIES APPROVED LIST.
CLASS J FUSE, 200KAIC RATING.
11. (E) MAIN SERVICE EQUIPMENT: 1 PHASE 3
WIRE 120/240 VAC, 200A
12. (N) CELL-B-R05-US-S-S2 CELL CARD
13. (9) SOLAREDGE BAT-10K1P BATTERIES,
9.70KWH, 5,000DCW, NEMA 3R, MOUNTED
TO WALL OR MANUFACTURER FLOOR
MOUNT KIT
14. (N) DC DISCONNECT SWITCH
15. (N) POLARIS BLOCKS
16. NOT USED
1.(E) MAIN SWITCHGEAR AND (N) POINT OF
AC INTERCONNECTION. ALL
CONNECTIONS MADE INSIDE (E)
SWITCHGEAR AT OTHER THAN CIRCUIT
BREAKERS OR FUSED SWITCHES LISTED
FOR USE WITH THAT SWITCHGEAR SHALL
BE PERFORMED FOLLOWING
MANUFACTURERS INSTRUCTIONS OR BE
RE-LISTED BY A NRTL. ALL TERMINATIONS
OF ALUMINUM CONDUCTORS SHALL BE
WITH HIGH PRESS CRIMP LUGS ONLY.
WARNING LABEL DETAIL 1/E800
2.(E) UTILITY TENANT LOAD METER. UTILITY
REFERENCE METER NUMBER:
222010-847068
3.(N) PV SYSTEM UTILITY AC DISCONNECT
'ACDS-1'. WARNING LABEL DETAIL 1/E810
4.(N) UTILITY BIDIRECTIONAL KWH METER.
WARNING LABEL DETAIL 1/E810
5.(N) PV SYSTEM MAINTENANCE AC
DISCONNECT 'ACDS-2'. WARNING LABEL
DETAIL 2/E800 & 1/E810
6.NOT USED
7.(N) GRID-INTERACTIVE PV INVERTER
LISTED TO UL 1741 WITH GROUND FAULT
DETECTION & INTERRUPTION. WARNING
LABEL DETAIL 15/E800.
8.NOT USED
9.NOT USED
10.FOR SUPPLY SIDE CONNECTIONS, A
PLAQUE SHALL BE INSTALLED AT THE
MAIN SERVICE DISCONNECTING DEVICE
AND THE PV SYSTEM UTILITY AC
DISCONNECT INDICATING THE LOCATION
OF THE RESPECTIVE SERVICE
DISCONNECT. WARNING LABEL DETAIL
1/E800 & 1/E810
11.NOT USED
12.CONDUCTORS RUN IN PARALLEL SHALL
BE INSTALLED PER ART 310.4/310.10(G)
AND 250.122 (F).
13.NOT USED
14.NEW PULL/JUNCTION BOXES. PROVIDE
SERVICE LOOP IN ALL DC BRANCH
CONDUCTORS SOURCED FROM
ROOFTOPS, MIN LOOP RADIUS = 12X
CONDUCTOR DIAMETER.
15.NOT USED
16.(N) INVERTER INTERNAL DC DISCONNECT
SWITCH(ES). WARNING LABEL DETAIL
3/E800
17.NOT USED
18.(N) PV MODULE LISTED TO UL 1703.
19.EXTRA MODULES THAT ARE UNABLE TO
BE PAIRED WILL HAVE THEIR OWN
OPTIMIZER.
20.(N) COMMUNICATION WIRING TO FOLLOW
MANUFACTURING SPECIFICATIONS.
21.DURING UTILITY GRID OUTAGE THE PV
GENERATION AND BESS WILL
DISCONNECT FROM THE GRID AND
REMAIN DISCONNECTED UNTIL GRID
VOLTAGE IS RESTORED TO THE
ACCEPTED MEASURE.
22.BATTERY AC OUTPUT POWER IS LIMITED
TO THE CORRESPONDING INVERTER OR
TOTAL BATTERIES CONNECTED TO A
SINGLE INVERTER,WHICHEVER IS LOWER.
23.BATTERIES SHOULD NOT BE INSTALLED IN
DIRECT SUNLIGHT OR LOCATIONS
SUBJECTED TO WATER SPRAY.
SPRINKLERS SHOULD BE DIVERTED
WHEN NECESSARY.
24.BATTERIES CAN COMMUNICATE
WIRELESSLY OR VIA RS-485 TO INVERTER.
BATTERIES WITHIN 150' (IDEALLY 50') OF
RESPECTIVE INVERTER CAN USE
WIRELESS COMMUNICATIONS VIA SEDG
HOME NETWORK CARD.
25.COMBINED PV AND BESS OUTPUT POWER
IS LIMITED TO THE INVERTER AC RATING.
26.SOLAREDGE ENERGY BANK MAY BE
WALL, FLOOR, OR PAD MOUNTED
INDIVIDUALLY OR IN GROUPS OF (2), (3),
OR (4) UTILIZING THE SOLAREDGE FLOOR
MOUNT STAND. ENERGY BANK MEETS
THE UNIT LEVEL PERFORMANCE
CRITERIA OF UL 9540A, ALLOWING
ENERGY BANK TO BE STACKED FRONT TO
BACK AS LONG AS THE CLEARANCE
REQUIREMENTS ARE FOLLOWED TO
ALLOW FOR AIR FLOW AROUND THE
UNITS.
ENTRENCHED
~10' PVC-80
EMT
EMT
ENTRENCHED
~10' PVC-80
EMT
EMT
ENTRENCHED
~10' PVC-80
EMT
EMT
ENTRENCHED
~10' PVC-80
EMT
EMT ENTRENCHED
~10' PVC-80
EMT
ENTRENCHED
~10' PVC-80
EMT
EMT
ENTRENCHED
~10' PVC-80
EMT
ENTRENCHED
~10' PVC-80
EMT
EMT
M
M
M
M
M FACILITY
LOADS
(E) TENANT
METERS (TYP.)
(N) POLARIS
BLOCK
-
A
11101
15
200A
UTILITY METER REFERENCE NUMBER:
222010-847068
SCE UTILITY GRID 240V, 1ø,3W
RMC ONLY
1221 E WILSHIRE AVE
E401
G
BLDG
1221
GEC
1221 E WILSHIRE AVE
E401
G
BLDG
1225
GEC
1225 E WILSHIRE AVE
E401
G
BLDG
1225
GEC
1225 E WILSHIRE AVE
E500
D
E500
D
E500
D
PARKING STRUCTURE
NEW ADDRESS TO BE
ASSIGNED
AHJ NOTES:
1.FUSED AC DISCONNECTS MUST BE SUSE RATED WITH A MAIN BONDING JUMPER
INSTALLED. CEC 230.82(6)
2.THE "GROUND" WIRE OF FUSED AC DISCONNECTS IS A GROUNDING ELECTRODE
CONDUCTOR TO BE BONDED TO THE GEC SYSTEM OF THE BUILDING
3.DISCONNECTS MUST BE WITHIN RMC TO THE POI. THE DISCONNECT AND THE
SUPPLY-SIDE POI MUST BE SEALED BY SCE. THIS IS CITY POLICY FOR SE
CONDUCTORS TO MINIMIZE POWER THEFT AND DAMAGE.
TO
GEC
EGCRMC ONLY
RMC ONLY
WEATHERHEAD - UTILITY
TERMINATION POINT
SCE CECTION
CUSTOMER
SECTION
DISTANCE FROM FUSED
ACD TO POI ~ 5 FT
UTILITY TERMINATION
POI-2 AC WIRE SCHEDULE
LABEL DESTINATION NOMINAL VAC LINE SELECTION FLA FLAX1.25 OCPD PHASE
CONDUCTOR
NEUTRAL
CONDUCTOR
GROUNDING
CONDUCTOR
CONDUCTORS PER
PHASE
CONDUIT QTY 75°C AMPS 90°C AMPS 90°C AMPS W/
C.O.U
C.O.U TEMP
DERATE
C.O.U CONDUIT
FILL
CIRCUIT LENGTH ²SEGMENT VD%DC/AC RATIO AFC START AFC END ⁴EMT IMC PVC 40 PVC 80
INV-2.1 LC-2.1 240 A-B 47.5 59.4 60 CU #6 CU #10 CU #10 1 1 65 75 68.3 91%100%60 1.12%151.1%5,810 2,643 3/4"3/4"3/4"3/4"
INV-2.2 LC-2.1 240 A-B 47.5 59.4 60 CU #6 CU #10 CU #10 1 1 65 75 68.3 91%100%60 1.12%133.1%5,810 2,643 3/4"3/4"3/4"3/4"
INV-2.3 LC-2.1 240 A-B 47.5 59.4 60 CU #6 CU #10 CU #10 1 1 65 75 68.3 91%100%60 1.12%133.1%5,810 2,643 3/4"3/4"3/4"3/4"
LC-2.1 AC-2.2 240 A-B 142.5 178.1 200 CU #3/0 CU #6 CU #6 1 1 200 225 204.8 91%100%19 0.17%--6,258 5,810 1 1/2"1 1/4"1 1/2"1 1/2"
AC-2.2 AC-2.1 240 A-B 142.5 178.1 200 CU #3/0 CU #6 CU #6 1 1 200 225 204.8 91%100%10 0.09%--6,523 6,258 1 1/2"1 1/4"1 1/2"1 1/2"
AC-2.1 POI-2.2 240 A-B 142.5 178.1 200 CU #3/0 CU #3/0 CU #4 1 1 200 225 204.8 91%100%5 0.05%--42,000 36,964 2"1 1/2"2"2"
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
POI-2 ONE LINE
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
E601
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#ESTAMP
WILSHIRE MINNIE
1221 E WILSHIRE AVE UNIT# MTR02
1221 3/4 E WILSHIRE AVE UNIT# ELE01
APN: 014-251-49
DEVELOPER:
C&C DEVELOPMENT
##KEYED NOTES#EQUIPMENT NOTES#
#
COMMUNICATION
CAT5E 600V RATED SHIELDED CABLE.
INSTALLER SHALL FOLLOW
MANUFACTURES RECOMMENDATION FOR
WIRE SIZING BASED ON LENGTH.
CIRCUIT IDENTIFIER
EQUIPMENT INDEX
EQUIPMENT TYPE
SYSTEM IDENTIFIER X INDICATES LETTERS
# INDICATES NUMBERS
XX-#.#
SYSTEM SUMMARY
34.20 ACKW | 46.74 DCKW | 43.55 CECKW
34.20 BESS ACKW | 87.30 BESS KWH
TOTAL FAULT CURRENTS
UTILITY: 42,000A | GENERATORS: 222A
DESCRIPTION OF OPERATION (DOO)
1.INVERTERS WITH ESS ARE CERTIFIED TO UL 1741 PCS CRD AND WILL HAVE
EXPORT-ONLY MODES ENABLED. THEY WILL UTILIZE EXCESS PV POWER TO CHARGE
THE BATTERIES AND THE BATTERIES WILL DISCHARGE DURING SET HOURS.
2.THE PRODUCER'S STORAGE DEVICE(S) WILL NOT CONSUME POWER FROM THE
DISTRIBUTION PROVIDER'S DISTRIBUTION SYSTEM AT ANY TIME.
3.GRID EXPORT IS ALLOWED THROUGH NEMV METER.
4.DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT
FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO
THE ACCEPTABLE MEASURE.
+-
18
14
1
13
14
ES-1
(3
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
3
.
1
.
A
-
(
1
2
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
2
)
U
6
5
0
O
P
T
S
.
ST
R
-
3
.
1
.
B
-
(
1
2
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
2
)
U
6
5
0
O
P
T
S
.
ST
R
-
3
.
1
.
C
-
(
1
2
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
2
)
U
6
5
0
O
P
T
S
.
14
ES-2
DC-3.1.1
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4
A-B
60A
INV-3.1
+-
18
14
1
13
14
ES-1
(3
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
3
.
2
.
A
-
(
1
2
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
2
)
U
6
5
0
O
P
T
S
.
ST
R
-
3
.
2
.
B
-
(
1
2
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
2
)
U
6
5
0
O
P
T
S
.
ST
R
-
3
.
2
.
C
-
(
1
2
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
2
)
U
6
5
0
O
P
T
S
.
14
ES-2
DC-3.2.2
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4
A-B
60A
INV-3.2
+-
18
14
1
13
14
ES-1
(3
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
3
.
3
.
A
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
ST
R
-
3
.
3
.
B
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
ST
R
-
3
.
3
.
C
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
14
ES-2
DC-3.3.3
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4
A-B
60A
INV-3.3
6
LC-3.1
6
8
5
(N) ACDS-2 SYSTEM AC DISCONNECT
SWITCH,, SQUARE D, VHU364R, 600V RATED,
240V OPERATIONAL, 200A, 3 POLE,
NON-FUSIBLE, NEMA 3R. VISIBLE, LOCKABLE.
SEE REFERENCE SHEETS FOR KAIC RATING.
AC-3.2
M9
4
(N) SCE PV PRODUCTION METER SOCKET
ADDRESS: 1229 E WILSHIRE AVE UNIT#
MTR02, COOPER B-LINE, 124TB, 200 A,
SERVICE 1 PHASE 3 WIRE 120/240 VAC, NEMA
3R
AC-3.2
10
3
(N) ACDS-1 SYSTEM UTILITY AC DISCONNECT
SWITCH, SQUARE D, VH224NR, 240V RATED,
240V OPERATIONAL, 200A, 2 POLE, FUSIBLE,
NEMA 3R, OR EQUIVALENT ON THE UTILITIES
APPROVED LIST. VISIBLE, LOCKABLE.
CLASS J FUSE, 200KAIC RATING.
A-B
200A
AC-3.1
A INTERCONNECTION LOCATION
NTS
1229 E WILSHIRE AVE UNIT# MTR02
POI-3 DC STRING SCHEDULE
STR-A STR-B STR-C
TAG DESTINATION CIRCUIT LENGTH ²VD%MODULE
WATTAGE
MODULE QTY OPTIMIZER MIN/MAX
MODULES
CIRCUIT LENGTH ²VD%MODULE
WATTAGE
MODULE QTY OPTIMIZER MIN/MAX
MODULES
CIRCUIT LENGTH ²VD%MODULE
WATTAGE
MODULE QTY OPTIMIZER MIN/MAX
MODULES
DC-3.1.1 INV-3.1 60 0.31%410 12 U650 8 / 16¹85 0.41%410 12 U650 8 / 16¹90 0.46%410 12 U650 8 / 16¹
DC-3.2.2 INV-3.2 60 0.31%410 12 U650 8 / 16¹65 0.31%410 12 U650 8 / 16¹80 0.41%410 12 U650 8 / 16¹
DC-3.3.3 INV-3.3 100 0.59%410 14 U650 8 / 16¹105 0.59%410 14 U650 8 / 16¹110 0.65%410 14 U650 8 / 16¹
¹ MAXIMUM STRING LENGTH IS USING MANUFACTURES EXCEPTION
² LENGTHS ARE ESTIMATED FOR CALCULATIONS, CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS AND TAKEOFFS
³ WHERE EXPOSED TO PHYSICAL DAMAGE #6 TO BE USED PER NEC 250.120(C)
⁴ AFC VALUES ARE CALCULATED BASED ON WIRE LENGTHS. LENGTHS SHOULD REMAIN GREATER THAN OR EQUAL TO THE LENGTH LISTED IN THE TABLE.
POI-3 DC WIRE SCHEDULE
TAG WIRE GAUGE CONDUCTOR
JACKET
MAX ISC 1.25 X MAX
CIRCUIT AMPS
CIRCUIT FUSE
RATING
CCC PER
CONDUIT
MAX AMBIENT
TEMP (C)
C.O.U TEMP.
DERATE
C.O.U CONDUIT
FILL DERATE
75°C AMPACITY COMPLIES WITH
690.8(B)(1)
90°C AMPACITY
WITH C.O.U
COMPLIES WITH
690.8(B)(2)
FAULT CURRENT
FROM PARALLEL
STRINGS
COMPLIES WITH
690.9(A)
GROUNDING
PER CONDUIT
GROUNDING ³EMT RMC PVC 40 PVC 80
DC-3.1.1 CU #8 THWN2 15 18.75 NONE 6 38 91%80%50 YES 40.0 YES 30 YES 3 CU #10 1"1"1"1 1/4"
DC-3.2.2 CU #8 THWN2 15 18.75 NONE 6 38 91%80%50 YES 40.0 YES 30 YES 3 CU #10 1"1"1"1 1/4"
DC-3.3.3 CU #8 THWN2 15 18.75 NONE 6 38 91%80%50 YES 40.0 YES 30 YES 3 CU #10 1"1"1"1 1/4"
LINE SIDE TAP VIA POLARIS TAPS
(POINT OF INTERCONNECTION)
SCE METER
1. PV MODULES (114) QCELLS NORTH
AMERICA Q.PEAK DUO BLK ML-G10.C+ 410
2. (114) SOLAREDGE DC OPTIMIZER U650
3. DC PV AND ESS CONNECTION UNIT W/
INTEGRAL LOAD BREAK DISCONNECT
4. (3) SOLAREDGE SE11400H-US HOME HUB
[240V] [SI1-SB] [CRD-PCS NEM], 11,400W,
240VAC, 1ø, 3W
5. (N) REVENUE GRADE METER, 1ø,
INTERGRATED RGM, W/ NOT REQUIRED
CTS
6. (1) LOAD CENTER, 200A, 1ø, MIN.240VAC,
MIN. 10KAIC, NEMA 3R
7. NOT USED
8.(N) ACDS-2 SYSTEM AC DISCONNECT
SWITCH, SQUARE D, VHU364R, 600V
RATED, 240V OPERATIONAL, 200A, 3 POLE,
NON-FUSIBLE, NEMA 3R. SEE REFERENCE
SHEETS FOR KAIC RATING.
9. (N) SCE PV PRODUCTION METER SOCKET
ADDRESS: 1229 E WILSHIRE AVE UNIT#
MTR02, COOPER B-LINE, 124TB, 200A,
SERVICE: 1 PHASE 3 WIRE 120/240 VAC, #
JAW, NEMA 3R, EUSERC: 305
10. (N) ACDS-1 SYSTEM UTILITY AC
DISCONNECT SWITCH, SQUARE D,
VH224NR, 240V RATED, 240V
OPERATIONAL, 200A, 2 POLE, FUSIBLE,
NEMA 3R, OR EQUIVALENT ON THE
UTILITIES APPROVED LIST.
CLASS J FUSE, 200KAIC RATING.
11. (E) MAIN SERVICE EQUIPMENT: 1 PHASE 3
WIRE 120/240 VAC, 200A
12. (N) CELL-B-R05-US-S-S2 CELL CARD
13. (9) SOLAREDGE BAT-10K1P BATTERIES,
9.70KWH, 5,000DCW, NEMA 3R, MOUNTED
TO WALL OR MANUFACTURER FLOOR
MOUNT KIT
14. (N) DC DISCONNECT SWITCH
15. (N) POLARIS BLOCKS
16. NOT USED
1.(E) MAIN SWITCHGEAR AND (N) POINT OF
AC INTERCONNECTION. ALL
CONNECTIONS MADE INSIDE (E)
SWITCHGEAR AT OTHER THAN CIRCUIT
BREAKERS OR FUSED SWITCHES LISTED
FOR USE WITH THAT SWITCHGEAR SHALL
BE PERFORMED FOLLOWING
MANUFACTURERS INSTRUCTIONS OR BE
RE-LISTED BY A NRTL. ALL TERMINATIONS
OF ALUMINUM CONDUCTORS SHALL BE
WITH HIGH PRESS CRIMP LUGS ONLY.
WARNING LABEL DETAIL 1/E800
2.(E) UTILITY TENANT LOAD METER. UTILITY
REFERENCE METER NUMBER:
222012-828414
3.(N) PV SYSTEM UTILITY AC DISCONNECT
'ACDS-1'. WARNING LABEL DETAIL 1/E810
4.(N) UTILITY BIDIRECTIONAL KWH METER.
WARNING LABEL DETAIL 1/E810
5.(N) PV SYSTEM MAINTENANCE AC
DISCONNECT 'ACDS-2'. WARNING LABEL
DETAIL 2/E800 & 1/E810
6.NOT USED
7.(N) GRID-INTERACTIVE PV INVERTER
LISTED TO UL 1741 WITH GROUND FAULT
DETECTION & INTERRUPTION. WARNING
LABEL DETAIL 15/E800.
8.NOT USED
9.NOT USED
10.FOR SUPPLY SIDE CONNECTIONS, A
PLAQUE SHALL BE INSTALLED AT THE
MAIN SERVICE DISCONNECTING DEVICE
AND THE PV SYSTEM UTILITY AC
DISCONNECT INDICATING THE LOCATION
OF THE RESPECTIVE SERVICE
DISCONNECT. WARNING LABEL DETAIL
1/E800 & 1/E810
11.NOT USED
12.CONDUCTORS RUN IN PARALLEL SHALL
BE INSTALLED PER ART 310.4/310.10(G)
AND 250.122 (F).
13.NOT USED
14.NEW PULL/JUNCTION BOXES. PROVIDE
SERVICE LOOP IN ALL DC BRANCH
CONDUCTORS SOURCED FROM
ROOFTOPS, MIN LOOP RADIUS = 12X
CONDUCTOR DIAMETER.
15.NOT USED
16.(N) INVERTER INTERNAL DC DISCONNECT
SWITCH(ES). WARNING LABEL DETAIL
3/E800
17.NOT USED
18.(N) PV MODULE LISTED TO UL 1703.
19.EXTRA MODULES THAT ARE UNABLE TO
BE PAIRED WILL HAVE THEIR OWN
OPTIMIZER.
20.(N) COMMUNICATION WIRING TO FOLLOW
MANUFACTURING SPECIFICATIONS.
21.DURING UTILITY GRID OUTAGE THE PV
GENERATION AND BESS WILL
DISCONNECT FROM THE GRID AND
REMAIN DISCONNECTED UNTIL GRID
VOLTAGE IS RESTORED TO THE
ACCEPTED MEASURE.
22.BATTERY AC OUTPUT POWER IS LIMITED
TO THE CORRESPONDING INVERTER OR
TOTAL BATTERIES CONNECTED TO A
SINGLE INVERTER,WHICHEVER IS LOWER.
23.BATTERIES SHOULD NOT BE INSTALLED IN
DIRECT SUNLIGHT OR LOCATIONS
SUBJECTED TO WATER SPRAY.
SPRINKLERS SHOULD BE DIVERTED
WHEN NECESSARY.
24.BATTERIES CAN COMMUNICATE
WIRELESSLY OR VIA RS-485 TO INVERTER.
BATTERIES WITHIN 150' (IDEALLY 50') OF
RESPECTIVE INVERTER CAN USE
WIRELESS COMMUNICATIONS VIA SEDG
HOME NETWORK CARD.
25.COMBINED PV AND BESS OUTPUT POWER
IS LIMITED TO THE INVERTER AC RATING.
26.SOLAREDGE ENERGY BANK MAY BE
WALL, FLOOR, OR PAD MOUNTED
INDIVIDUALLY OR IN GROUPS OF (2), (3),
OR (4) UTILIZING THE SOLAREDGE FLOOR
MOUNT STAND. ENERGY BANK MEETS
THE UNIT LEVEL PERFORMANCE
CRITERIA OF UL 9540A, ALLOWING
ENERGY BANK TO BE STACKED FRONT TO
BACK AS LONG AS THE CLEARANCE
REQUIREMENTS ARE FOLLOWED TO
ALLOW FOR AIR FLOW AROUND THE
UNITS.
ENTRENCHED
~13' PVC-80
EMT
EMT
ENTRENCHED
~13' PVC-80
EMT
EMT
ENTRENCHED
~13' PVC-80
EMT
EMT
ENTRENCHED
~13' PVC-80
EMT
EMT
ENTRENCHED
~13' PVC-80
EMT
EMT
ENTRENCHED
~20' PVC-80
EMT
ENTRENCHED
~13' PVC-80
EMT
EMT
M
M
M
M
M FACILITY
LOADS
(E) TENANT
METERS (TYP.)
(N) POLARIS
BLOCK
-
A
11101
15
200A
UTILITY METER REFERENCE NUMBER:
222012-828414
SCE UTILITY GRID 240V, 1ø,3W
RMC ONLY
1229 E WILSHIRE AVE
E401
G
BLDG
1229
GEC
1229 E WILSHIRE AVE
E401
G
BLDG
1229
GEC
1229 E WILSHIRE AVE
E401
G
BLDG
1235
GEC
1235 E WILSHIRE AVE
E500
D
E500
D
E500
D
PARKING STRUCTURE
NEW ADDRESS TO BE
ASSIGNED
AHJ NOTES:
1.FUSED AC DISCONNECTS MUST BE SUSE RATED WITH A MAIN BONDING JUMPER
INSTALLED. CEC 230.82(6)
2.THE "GROUND" WIRE OF FUSED AC DISCONNECTS IS A GROUNDING ELECTRODE
CONDUCTOR TO BE BONDED TO THE GEC SYSTEM OF THE BUILDING
3.DISCONNECTS MUST BE WITHIN RMC TO THE POI. THE DISCONNECT AND THE
SUPPLY-SIDE POI MUST BE SEALED BY SCE. THIS IS CITY POLICY FOR SE
CONDUCTORS TO MINIMIZE POWER THEFT AND DAMAGE.
TO
GEC
EGCRMC ONLY
RMC ONLY
WEATHERHEAD - UTILITY
TERMINATION POINT
SCE CECTION
CUSTOMER
SECTION
DISTANCE FROM FUSED
ACD TO POI ~ 5 FT
UTILITY TERMINATION
POI-3 AC WIRE SCHEDULE
LABEL DESTINATION NOMINAL VAC LINE SELECTION FLA FLAX1.25 OCPD PHASE
CONDUCTOR
NEUTRAL
CONDUCTOR
GROUNDING
CONDUCTOR
CONDUCTORS PER
PHASE
CONDUIT QTY 75°C AMPS 90°C AMPS 90°C AMPS W/
C.O.U
C.O.U TEMP
DERATE
C.O.U CONDUIT
FILL
CIRCUIT LENGTH ²SEGMENT VD%DC/AC RATIO AFC START AFC END ⁴EMT IMC PVC 40 PVC 80
INV-3.1 LC-3.1 240 A-B 47.5 59.4 60 CU #6 CU #10 CU #10 1 1 65 75 68.3 91%100%65 1.21%129.5%5,810 2,528 3/4"3/4"3/4"3/4"
INV-3.2 LC-3.1 240 A-B 47.5 59.4 60 CU #6 CU #10 CU #10 1 1 65 75 68.3 91%100%65 1.21%129.5%5,810 2,528 3/4"3/4"3/4"3/4"
INV-3.3 LC-3.1 240 A-B 47.5 59.4 60 CU #6 CU #10 CU #10 1 1 65 75 68.3 91%100%65 1.21%151.1%5,810 2,528 3/4"3/4"3/4"3/4"
LC-3.1 AC-3.2 240 A-B 142.5 178.1 200 CU #3/0 CU #6 CU #6 1 1 200 225 204.8 91%100%19 0.17%--6,258 5,810 1 1/2"1 1/4"1 1/2"1 1/2"
AC-3.2 AC-3.1 240 A-B 142.5 178.1 200 CU #3/0 CU #6 CU #6 1 1 200 225 204.8 91%100%10 0.09%--6,523 6,258 1 1/2"1 1/4"1 1/2"1 1/2"
AC-3.1 POI-3.3 240 A-B 142.5 178.1 200 CU #3/0 CU #3/0 CU #4 1 1 200 225 204.8 91%100%5 0.05%--42,000 36,964 2"1 1/2"2"2"
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
POI-3 ONE LINE
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
E602
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#ESTAMP
WILSHIRE MINNIE
1229 E WILSHIRE AVE UNIT# MTR02
1229 3/4 E WILSHIRE AVE UNIT# ELE01
APN: 014-251-49
DEVELOPER:
C&C DEVELOPMENT
##KEYED NOTES#EQUIPMENT NOTES#
#
COMMUNICATION
CAT5E 600V RATED SHIELDED CABLE.
INSTALLER SHALL FOLLOW
MANUFACTURES RECOMMENDATION FOR
WIRE SIZING BASED ON LENGTH.
CIRCUIT IDENTIFIER
EQUIPMENT INDEX
EQUIPMENT TYPE
SYSTEM IDENTIFIER X INDICATES LETTERS
# INDICATES NUMBERS
XX-#.#
SYSTEM SUMMARY
19.00 ACKW | 28.70 DCKW | 26.74 CECKW
19.00 BESS ACKW | 58.20 BESS KWH
TOTAL FAULT CURRENTS
UTILITY: 42,000A | GENERATORS: 148A
DESCRIPTION OF OPERATION (DOO)
1.INVERTERS WITH ESS ARE CERTIFIED TO UL 1741 PCS CRD AND WILL HAVE
EXPORT-ONLY MODES ENABLED. THEY WILL UTILIZE EXCESS PV POWER TO CHARGE
THE BATTERIES AND THE BATTERIES WILL DISCHARGE DURING SET HOURS.
2.THE PRODUCER'S STORAGE DEVICE(S) WILL NOT CONSUME POWER FROM THE
DISTRIBUTION PROVIDER'S DISTRIBUTION SYSTEM AT ANY TIME.
3.GRID EXPORT IS ALLOWED THROUGH NEMV METER.
4.DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT
FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO
THE ACCEPTABLE MEASURE.
+-
18
14
1
13
14
ES-1
(3
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
4
.
1
.
A
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
ST
R
-
4
.
1
.
B
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
ST
R
-
4
.
1
.
C
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
14
ES-2
DC-4.1.1
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4A
A-B
60A
INV-4.1
+-
18
14
1
13
14
ES-1
(3
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
4
.
2
.
A
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
ST
R
-
4
.
2
.
B
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
14
ES-2
DC-4.2.2
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4B
A-B
40A
INV-4.2
6
LC-4.1
6
8
5
(N) ACDS-2 SYSTEM AC DISCONNECT
SWITCH,, SQUARE D, VHU363RB, 600V RATED,
240V OPERATIONAL, 100A, 3 POLE,
NON-FUSIBLE, NEMA 3R. VISIBLE, LOCKABLE.
SEE REFERENCE SHEETS FOR KAIC RATING.
AC-4.2
M9
4
(N) SCE PV PRODUCTION METER SOCKET
ADDRESS: 1233 E WILSHIRE AVE UNIT#
MTR01, COOPER B-LINE, 114TB, 100 A,
SERVICE 1 PHASE 3 WIRE 120/240 VAC, NEMA
3R
AC-4.2
10
3
(N) ACDS-1 SYSTEM UTILITY AC DISCONNECT
SWITCH, SQUARE D, VH223NRB, 240V RATED,
240V OPERATIONAL, 100A, 2 POLE, FUSIBLE,
NEMA 3R, OR EQUIVALENT ON THE UTILITIES
APPROVED LIST. VISIBLE, LOCKABLE.
CLASS J FUSE, 200KAIC RATING.
A-B
100A
AC-4.1
A INTERCONNECTION LOCATION
NTS1233 E WILSHIRE AVE UNIT# MTR01
POI-4 DC STRING SCHEDULE
STR-A STR-B STR-C
TAG DESTINATION CIRCUIT LENGTH ²VD%MODULE
WATTAGE
MODULE QTY OPTIMIZER MIN/MAX
MODULES
CIRCUIT LENGTH ²VD%MODULE
WATTAGE
MODULE QTY OPTIMIZER MIN/MAX
MODULES
CIRCUIT LENGTH ²VD%MODULE
WATTAGE
MODULE QTY OPTIMIZER MIN/MAX
MODULES
DC-4.1.1 INV-4.1 70 0.42%410 14 U650 8 / 16¹100 0.56%410 14 U650 8 / 16¹75 0.45%410 14 U650 8 / 16¹
DC-4.2.2 INV-4.2 75 0.71%410 14 U650 8 / 16¹50 0.45%410 14 U650 8 / 16¹------------
¹ MAXIMUM STRING LENGTH IS USING MANUFACTURES EXCEPTION
² LENGTHS ARE ESTIMATED FOR CALCULATIONS, CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS AND TAKEOFFS
³ WHERE EXPOSED TO PHYSICAL DAMAGE #6 TO BE USED PER NEC 250.120(C)
⁴ AFC VALUES ARE CALCULATED BASED ON WIRE LENGTHS. LENGTHS SHOULD REMAIN GREATER THAN OR EQUAL TO THE LENGTH LISTED IN THE TABLE.
POI-4 DC WIRE SCHEDULE
TAG WIRE GAUGE CONDUCTOR
JACKET
MAX ISC 1.25 X MAX
CIRCUIT AMPS
CIRCUIT FUSE
RATING
CCC PER
CONDUIT
MAX AMBIENT
TEMP (C)
C.O.U TEMP.
DERATE
C.O.U CONDUIT
FILL DERATE
75°C AMPACITY COMPLIES WITH
690.8(B)(1)
90°C AMPACITY
WITH C.O.U
COMPLIES WITH
690.8(B)(2)
FAULT CURRENT
FROM PARALLEL
STRINGS
COMPLIES WITH
690.9(A)
GROUNDING
PER CONDUIT
GROUNDING ³EMT RMC PVC 40 PVC 80
DC-4.1.1 CU #8 THWN2 15 18.75 NONE 6 38 91%80%50 YES 40.0 YES 30 YES 3 CU #10 1"1"1"1 1/4"
DC-4.2.2 CU #10 THWN2 15 18.75 NONE 4 38 91%80%35 YES 29.1 YES 15 YES 2 CU #10 3/4"3/4"3/4"3/4"
LINE SIDE TAP VIA POLARIS TAPS
(POINT OF INTERCONNECTION)
SCE METER
1. PV MODULES (70) QCELLS NORTH
AMERICA Q.PEAK DUO BLK ML-G10.C+ 410
2. (70) SOLAREDGE DC OPTIMIZER U650
3. DC PV AND ESS CONNECTION UNIT W/
INTEGRAL LOAD BREAK DISCONNECT
4. 4A: (1) SOLAREDGE SE11400H-US HOME
HUB [240V] [SI1-SB] [CRD-PCS NEM],
11,400W, 240VAC, 1ø, 3W
4B: (1) SOLAREDGE SE7600H-US HOME
HUB [240V] [SI1-SB] [CRD-PCS NEM],
7,600W, 240VAC, 1ø, 3W
5. (N) REVENUE GRADE METER, 1ø,
INTERGRATED RGM, W/ NOT REQUIRED
CTS
6. (1) LOAD CENTER, 100A, 1ø, MIN.240VAC,
MIN. 10KAIC, NEMA 3R
7. NOT USED
8.(N) ACDS-2 SYSTEM AC DISCONNECT
SWITCH, SQUARE D, VHU363RB, 600V
RATED, 240V OPERATIONAL, 100A, 3 POLE,
NON-FUSIBLE, NEMA 3R. SEE REFERENCE
SHEETS FOR KAIC RATING.
9. (N) SCE PV PRODUCTION METER SOCKET
ADDRESS: 1233 E WILSHIRE AVE UNIT#
MTR01, COOPER B-LINE, 114TB, 100A,
SERVICE: 1 PHASE 3 WIRE 120/240 VAC, #
JAW, NEMA 3R, EUSERC: 304
10. (N) ACDS-1 SYSTEM UTILITY AC
DISCONNECT SWITCH, SQUARE D,
VH223NRB, 240V RATED, 240V
OPERATIONAL, 100A, 2 POLE, FUSIBLE,
NEMA 3R, OR EQUIVALENT ON THE
UTILITIES APPROVED LIST.
CLASS J FUSE, 200KAIC RATING.
11. (E) MAIN SERVICE EQUIPMENT: 1 PHASE 3
WIRE 120/240 VAC, 150A
12. (N) CELL-B-R05-US-S-S2 CELL CARD
13. (6) SOLAREDGE BAT-10K1P BATTERIES,
9.70KWH, 5,000DCW, NEMA 3R, MOUNTED
TO WALL OR MANUFACTURER FLOOR
MOUNT KIT
14. (N) DC SIDCONNECT SWITCH
15. (N) POLARIS BLOCKS
16. NOT USED
1.(E) MAIN SWITCHGEAR AND (N) POINT OF
AC INTERCONNECTION. ALL
CONNECTIONS MADE INSIDE (E)
SWITCHGEAR AT OTHER THAN CIRCUIT
BREAKERS OR FUSED SWITCHES LISTED
FOR USE WITH THAT SWITCHGEAR SHALL
BE PERFORMED FOLLOWING
MANUFACTURERS INSTRUCTIONS OR BE
RE-LISTED BY A NRTL. ALL TERMINATIONS
OF ALUMINUM CONDUCTORS SHALL BE
WITH HIGH PRESS CRIMP LUGS ONLY.
WARNING LABEL DETAIL 1/E800
2.(E) UTILITY TENANT LOAD METER. UTILITY
REFERENCE METER NUMBER:
222013-142908
3.(N) PV SYSTEM UTILITY AC DISCONNECT
'ACDS-1'. WARNING LABEL DETAIL 1/E810
4.(N) UTILITY BIDIRECTIONAL KWH METER.
WARNING LABEL DETAIL 1/E810
5.(N) PV SYSTEM MAINTENANCE AC
DISCONNECT 'ACDS-2'. WARNING LABEL
DETAIL 2/E800 & 1/E810
6.NOT USED
7.(N) GRID-INTERACTIVE PV INVERTER
LISTED TO UL 1741 WITH GROUND FAULT
DETECTION & INTERRUPTION. WARNING
LABEL DETAIL 15/E800.
8.NOT USED
9.NOT USED
10.FOR SUPPLY SIDE CONNECTIONS, A
PLAQUE SHALL BE INSTALLED AT THE
MAIN SERVICE DISCONNECTING DEVICE
AND THE PV SYSTEM UTILITY AC
DISCONNECT INDICATING THE LOCATION
OF THE RESPECTIVE SERVICE
DISCONNECT. WARNING LABEL DETAIL
1/E800 & 1/E810
11.NOT USED
12.CONDUCTORS RUN IN PARALLEL SHALL
BE INSTALLED PER ART 310.4/310.10(G)
AND 250.122 (F).
13.NOT USED
14.NEW PULL/JUNCTION BOXES. PROVIDE
SERVICE LOOP IN ALL DC BRANCH
CONDUCTORS SOURCED FROM
ROOFTOPS, MIN LOOP RADIUS = 12X
CONDUCTOR DIAMETER.
15.NOT USED
16.(N) INVERTER INTERNAL DC DISCONNECT
SWITCH(ES). WARNING LABEL DETAIL
3/E800
17.NOT USED
18.(N) PV MODULE LISTED TO UL 1703.
19.EXTRA MODULES THAT ARE UNABLE TO
BE PAIRED WILL HAVE THEIR OWN
OPTIMIZER.
20.(N) COMMUNICATION WIRING TO FOLLOW
MANUFACTURING SPECIFICATIONS.
21.DURING UTILITY GRID OUTAGE THE PV
GENERATION AND BESS WILL
DISCONNECT FROM THE GRID AND
REMAIN DISCONNECTED UNTIL GRID
VOLTAGE IS RESTORED TO THE
ACCEPTED MEASURE.
22.BATTERY AC OUTPUT POWER IS LIMITED
TO THE CORRESPONDING INVERTER OR
TOTAL BATTERIES CONNECTED TO A
SINGLE INVERTER,WHICHEVER IS LOWER.
23.BATTERIES SHOULD NOT BE INSTALLED IN
DIRECT SUNLIGHT OR LOCATIONS
SUBJECTED TO WATER SPRAY.
SPRINKLERS SHOULD BE DIVERTED
WHEN NECESSARY.
24.BATTERIES CAN COMMUNICATE
WIRELESSLY OR VIA RS-485 TO INVERTER.
BATTERIES WITHIN 150' (IDEALLY 50') OF
RESPECTIVE INVERTER CAN USE
WIRELESS COMMUNICATIONS VIA SEDG
HOME NETWORK CARD.
25.COMBINED PV AND BESS OUTPUT POWER
IS LIMITED TO THE INVERTER AC RATING.
26.SOLAREDGE ENERGY BANK MAY BE
WALL, FLOOR, OR PAD MOUNTED
INDIVIDUALLY OR IN GROUPS OF (2), (3),
OR (4) UTILIZING THE SOLAREDGE FLOOR
MOUNT STAND. ENERGY BANK MEETS
THE UNIT LEVEL PERFORMANCE
CRITERIA OF UL 9540A, ALLOWING
ENERGY BANK TO BE STACKED FRONT TO
BACK AS LONG AS THE CLEARANCE
REQUIREMENTS ARE FOLLOWED TO
ALLOW FOR AIR FLOW AROUND THE
UNITS.
M
M
M
M
M FACILITY
LOADS
(E) TENANT
METERS (TYP.)
(N) POLARIS
BLOCK
-
A
11101
15
200A
UTILITY METER REFERENCE NUMBER:
222013-142908
SCE UTILITY GRID 240V, 1ø,3W
RMC ONLY
ENTRENCHED
~10' PVC-80
EMT
EMT
ENTRENCHED
~10' PVC-80
EMT
EMT
ENTRENCHED
~10' PVC-80
EMT
EMT
1233 E WILSHIRE AVE
E401
G
BLDG
1233
GEC
1233 E WILSHIRE AVE
E401
G
BLDG
1233
GEC
1233 E WILSHIRE AVE
ON ESS
CONCRETE
PAD
E500
D
E500
D
AHJ NOTES:
1.FUSED AC DISCONNECTS MUST BE SUSE RATED WITH A MAIN BONDING JUMPER
INSTALLED. CEC 230.82(6)
2.THE "GROUND" WIRE OF FUSED AC DISCONNECTS IS A GROUNDING ELECTRODE
CONDUCTOR TO BE BONDED TO THE GEC SYSTEM OF THE BUILDING
3.DISCONNECTS MUST BE WITHIN RMC TO THE POI. THE DISCONNECT AND THE
SUPPLY-SIDE POI MUST BE SEALED BY SCE. THIS IS CITY POLICY FOR SE
CONDUCTORS TO MINIMIZE POWER THEFT AND DAMAGE.
TO
GEC
EGCRMC ONLY
RMC ONLY
WEATHERHEAD - UTILITY
TERMINATION POINT
SCE CECTION
CUSTOMER
SECTION
DISTANCE FROM FUSED
ACD TO POI ~ 5 FT
UTILITY TERMINATION
POI-4 AC WIRE SCHEDULE
LABEL DESTINATION NOMINAL VAC LINE SELECTION FLA FLAX1.25 OCPD PHASE
CONDUCTOR
NEUTRAL
CONDUCTOR
GROUNDING
CONDUCTOR
CONDUCTORS PER
PHASE
CONDUIT QTY 75°C AMPS 90°C AMPS 90°C AMPS W/
C.O.U
C.O.U TEMP
DERATE
C.O.U CONDUIT
FILL
CIRCUIT LENGTH ²SEGMENT VD%DC/AC RATIO AFC START AFC END ⁴EMT IMC PVC 40 PVC 80
INV-4.1 LC-4.1 240 A-B 47.5 59.4 60 CU #6 CU #10 CU #10 1 1 65 75 68.3 91%100%5 0.09%151.1%3,436 3,244 3/4"3/4"3/4"3/4"
INV-4.2 LC-4.1 240 A-B 31.7 39.6 40 CU #8 CU #10 CU #10 1 1 50 55 50.1 91%100%5 0.10%151.1%3,436 3,146 1/2"1/2"3/4"3/4"
LC-4.1 AC-4.2 240 A-B 79.2 99.0 100 CU #3 CU #8 CU #8 1 1 100 115 104.7 91%100%10 0.16%--3,655 3,436 1"1"1"1"
AC-4.2 AC-4.1 240 A-B 79.2 99.0 100 CU #3 CU #8 CU #8 1 1 100 115 104.7 91%100%10 0.16%--3,904 3,655 1"1"1"1"
AC-4.1 POI-4.4 240 A-B 79.2 99.0 100 CU #3 CU #3 CU #8 1 1 100 115 104.7 91%100%5 0.08%--42,000 30,734 1"1"1"1 1/4"
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
POI-4 ONE LINE
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
E603
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#ESTAMP
WILSHIRE MINNIE
1233 E WILSHIRE AVE UNIT# MTR01
APN: 014-251-49
DEVELOPER:
C&C DEVELOPMENT
##KEYED NOTES#EQUIPMENT NOTES#
#
COMMUNICATION
CAT5E 600V RATED SHIELDED CABLE.
INSTALLER SHALL FOLLOW
MANUFACTURES RECOMMENDATION FOR
WIRE SIZING BASED ON LENGTH.
CIRCUIT IDENTIFIER
EQUIPMENT INDEX
EQUIPMENT TYPE
SYSTEM IDENTIFIER X INDICATES LETTERS
# INDICATES NUMBERS
XX-#.#
SYSTEM SUMMARY
26.60 ACKW | 35.67 DCKW | 33.24 CECKW
25.20 BESS ACKW | 58.20 BESS KWH
TOTAL FAULT CURRENTS
UTILITY: 42,000A | GENERATORS: 222A
DESCRIPTION OF OPERATION (DOO)
1.INVERTERS WITH ESS ARE CERTIFIED TO UL 1741 PCS CRD AND WILL HAVE
EXPORT-ONLY MODES ENABLED. THEY WILL UTILIZE EXCESS PV POWER TO CHARGE
THE BATTERIES AND THE BATTERIES WILL DISCHARGE DURING SET HOURS.
2.THE PRODUCER'S STORAGE DEVICE(S) WILL NOT CONSUME POWER FROM THE
DISTRIBUTION PROVIDER'S DISTRIBUTION SYSTEM AT ANY TIME.
3.GRID EXPORT IS ALLOWED THROUGH NEMV METER.
4.DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT
FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO
THE ACCEPTABLE MEASURE.
+-
18
14
1
13
14
ES-1
(2
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
5
.
1
.
A
-
(
1
3
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
3
)
U
6
5
0
O
P
T
S
.
ST
R
-
5
.
1
.
B
-
(
1
3
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
3
)
U
6
5
0
O
P
T
S
.
ST
R
-
5
.
1
.
C
-
(
1
2
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
2
)
U
6
5
0
O
P
T
S
.
ES-2
DC-5.1.1
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4A
A-B
60A
INV-5.1
+-
18
14
1
13
14
ES-1
(2
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
5
.
2
.
A
-
(
1
3
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
3
)
U
6
5
0
O
P
T
S
.
ST
R
-
5
.
2
.
B
-
(
1
2
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
2
)
U
6
5
0
O
P
T
S
.
ES-2
DC-5.2.2
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4B
A-B
40A
INV-5.2
+-
18
14
1
13
14
ES-1
(2
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
5
.
3
.
A
-
(
1
3
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
3
)
U
6
5
0
O
P
T
S
.
ST
R
-
5
.
3
.
B
-
(
1
1
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
1
)
U
6
5
0
O
P
T
S
.
ES-2
DC-5.3.3
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4B
A-B
40A
INV-5.3
6
LC-5.1
6
8
5
(N) ACDS-2 SYSTEM AC DISCONNECT
SWITCH,, SQUARE D, VHU364R, 600V RATED,
240V OPERATIONAL, 200A, 3 POLE,
NON-FUSIBLE, NEMA 3R. VISIBLE, LOCKABLE.
SEE REFERENCE SHEETS FOR KAIC RATING.
AC-5.2
M9
4
(N) SCE PV PRODUCTION METER SOCKET
ADDRESS: 1401 S MINNIE ST UNIT# MTR01,
COOPER B-LINE, 124TB, 200 A, SERVICE 1
PHASE 3 WIRE 120/240 VAC, NEMA 3R
AC-5.2
10
3
(N) ACDS-1 SYSTEM UTILITY AC DISCONNECT
SWITCH, SQUARE D, VH224NR, 240V RATED,
240V OPERATIONAL, 200A, 2 POLE, FUSIBLE,
NEMA 3R, OR EQUIVALENT ON THE UTILITIES
APPROVED LIST. VISIBLE, LOCKABLE.
CLASS J FUSE, 200KAIC RATING.
A-B
150AAC-5.1
A INTERCONNECTION LOCATION
NTS1401 S MINNIE ST UNIT# MTR01
POI-5 DC STRING SCHEDULE
STR-A STR-B STR-C
TAG DESTINATION CIRCUIT LENGTH ²VD%MODULE
WATTAGE
MODULE QTY OPTIMIZER MIN/MAX
MODULES
CIRCUIT LENGTH ²VD%MODULE
WATTAGE
MODULE QTY OPTIMIZER MIN/MAX
MODULES
CIRCUIT LENGTH ²VD%MODULE
WATTAGE
MODULE QTY OPTIMIZER MIN/MAX
MODULES
DC-5.1.1 INV-5.1 70 0.39%410 13 U650 8 / 16¹75 0.39%410 13 U650 8 / 16¹80 0.41%410 12 U650 8 / 16¹
DC-5.2.2 INV-5.2 120 1.06%410 13 U650 8 / 16¹105 0.80%410 12 U650 8 / 16¹------------
DC-5.3.3 INV-5.3 80 0.70%410 13 U650 8 / 16¹90 0.63%410 11 U650 8 / 16¹------------
¹ MAXIMUM STRING LENGTH IS USING MANUFACTURES EXCEPTION
² LENGTHS ARE ESTIMATED FOR CALCULATIONS, CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS AND TAKEOFFS
³ WHERE EXPOSED TO PHYSICAL DAMAGE #6 TO BE USED PER NEC 250.120(C)
⁴ AFC VALUES ARE CALCULATED BASED ON WIRE LENGTHS. LENGTHS SHOULD REMAIN GREATER THAN OR EQUAL TO THE LENGTH LISTED IN THE TABLE.
POI-5 DC WIRE SCHEDULE
TAG WIRE GAUGE CONDUCTOR
JACKET
MAX ISC 1.25 X MAX
CIRCUIT AMPS
CIRCUIT FUSE
RATING
CCC PER
CONDUIT
MAX AMBIENT
TEMP (C)
C.O.U TEMP.
DERATE
C.O.U CONDUIT
FILL DERATE
75°C AMPACITY COMPLIES WITH
690.8(B)(1)
90°C AMPACITY
WITH C.O.U
COMPLIES WITH
690.8(B)(2)
FAULT CURRENT
FROM PARALLEL
STRINGS
COMPLIES WITH
690.9(A)
GROUNDING
PER CONDUIT
GROUNDING ³EMT RMC PVC 40 PVC 80
DC-5.1.1 CU #8 THWN2 15 18.75 NONE 6 38 91%80%50 YES 40.0 YES 30 YES 3 CU #10 1"1"1"1 1/4"
DC-5.2.2 CU #10 THWN2 15 18.75 NONE 4 38 91%80%35 YES 29.1 YES 15 YES 2 CU #10 3/4"3/4"3/4"3/4"
DC-5.3.3 CU #10 THWN2 15 18.75 NONE 4 38 91%80%35 YES 29.1 YES 15 YES 2 CU #10 3/4"3/4"3/4"3/4"
LINE SIDE TAP POINT OF INTERCONNECTION
USING MECHANICAL LUG
CUSTOMER SECTION
UTILITY SECTION
(N) GLASTIC BARRIER
SCE METER
SCE PULL SECTION
1. PV MODULES (87) QCELLS NORTH
AMERICA Q.PEAK DUO BLK ML-G10.C+ 410
2. (87) SOLAREDGE DC OPTIMIZER U650
3. DC PV AND ESS CONNECTION UNIT W/
INTEGRAL LOAD BREAK DISCONNECT
4. 4A: (1) SOLAREDGE SE11400H-US HOME
HUB [240V] [SI1-SB] [CRD-PCS NEM],
11,400W, 240VAC, 1ø, 3W
4B: (2) SOLAREDGE SE7600H-US HOME
HUB [240V] [SI1-SB] [CRD-PCS NEM],
7,600W, 240VAC, 1ø, 3W
5. (N) REVENUE GRADE METER, 1ø,
INTERGRATED RGM, W/ NOT REQUIRED
CTS
6. (1) LOAD CENTER, 200A, 1ø, MIN.240VAC,
MIN. 10KAIC, NEMA 3R
7. NOT USED
8.(N) ACDS-2 SYSTEM AC DISCONNECT
SWITCH, SQUARE D, VHU364R, 600V
RATED, 240V OPERATIONAL, 200A, 3 POLE,
NON-FUSIBLE, NEMA 3R. SEE REFERENCE
SHEETS FOR KAIC RATING.
9. (N) SCE PV PRODUCTION METER SOCKET
ADDRESS: 1401 S MINNIE ST UNIT# MTR01,
COOPER B-LINE, 124TB, 200A, SERVICE: 1
PHASE 3 WIRE 120/240 VAC, # JAW, NEMA
3R, EUSERC: 305
10. (N) ACDS-1 SYSTEM UTILITY AC
DISCONNECT SWITCH, SQUARE D,
VH224NR, 240V RATED, 240V
OPERATIONAL, 200A, 2 POLE, FUSIBLE,
NEMA 3R, OR EQUIVALENT ON THE
UTILITIES APPROVED LIST.
CLASS J FUSE, 200KAIC RATING.
11. (E) MAIN SERVICE EQUIPMENT: 1 PHASE 3
WIRE 120/240 VAC, 200A
12. (N) CELL-B-R05-US-S-S2 CELL CARD
13. (6) SOLAREDGE BAT-10K1P BATTERIES,
9.70KWH, 5,000DCW, NEMA 3R, MOUNTED
TO WALL OR MANUFACTURER FLOOR
MOUNT KIT
14. NOT USED
15. NOT USED
16. NOT USED
1.(E) MAIN SWITCHGEAR AND (N) POINT OF
AC INTERCONNECTION. ALL
CONNECTIONS MADE INSIDE (E)
SWITCHGEAR AT OTHER THAN CIRCUIT
BREAKERS OR FUSED SWITCHES LISTED
FOR USE WITH THAT SWITCHGEAR SHALL
BE PERFORMED FOLLOWING
MANUFACTURERS INSTRUCTIONS OR BE
RE-LISTED BY A NRTL. ALL TERMINATIONS
OF ALUMINUM CONDUCTORS SHALL BE
WITH HIGH PRESS CRIMP LUGS ONLY.
WARNING LABEL DETAIL 1/E800
2.(E) UTILITY TENANT LOAD METER. UTILITY
REFERENCE METER NUMBER:
222012-825599
3.(N) PV SYSTEM UTILITY AC DISCONNECT
'ACDS-1'. WARNING LABEL DETAIL 1/E810
4.(N) UTILITY BIDIRECTIONAL KWH METER.
WARNING LABEL DETAIL 1/E810
5.(N) PV SYSTEM MAINTENANCE AC
DISCONNECT 'ACDS-2'. WARNING LABEL
DETAIL 2/E800 & 1/E810
6.NOT USED
7.(N) GRID-INTERACTIVE PV INVERTER
LISTED TO UL 1741 WITH GROUND FAULT
DETECTION & INTERRUPTION. WARNING
LABEL DETAIL 15/E800.
8.NOT USED
9.NOT USED
10.FOR SUPPLY SIDE CONNECTIONS, A
PLAQUE SHALL BE INSTALLED AT THE
MAIN SERVICE DISCONNECTING DEVICE
AND THE PV SYSTEM UTILITY AC
DISCONNECT INDICATING THE LOCATION
OF THE RESPECTIVE SERVICE
DISCONNECT. WARNING LABEL DETAIL
1/E800 & 1/E810
11.NOT USED
12.CONDUCTORS RUN IN PARALLEL SHALL
BE INSTALLED PER ART 310.4/310.10(G)
AND 250.122 (F).
13.NOT USED
14.NEW PULL/JUNCTION BOXES. PROVIDE
SERVICE LOOP IN ALL DC BRANCH
CONDUCTORS SOURCED FROM
ROOFTOPS, MIN LOOP RADIUS = 12X
CONDUCTOR DIAMETER.
15.NOT USED
16.(N) INVERTER INTERNAL DC DISCONNECT
SWITCH(ES). WARNING LABEL DETAIL
3/E800
17.NOT USED
18.(N) PV MODULE LISTED TO UL 1703.
19.EXTRA MODULES THAT ARE UNABLE TO
BE PAIRED WILL HAVE THEIR OWN
OPTIMIZER.
20.(N) COMMUNICATION WIRING TO FOLLOW
MANUFACTURING SPECIFICATIONS.
21.DURING UTILITY GRID OUTAGE THE PV
GENERATION AND BESS WILL
DISCONNECT FROM THE GRID AND
REMAIN DISCONNECTED UNTIL GRID
VOLTAGE IS RESTORED TO THE
ACCEPTED MEASURE.
22.BATTERY AC OUTPUT POWER IS LIMITED
TO THE CORRESPONDING INVERTER OR
TOTAL BATTERIES CONNECTED TO A
SINGLE INVERTER,WHICHEVER IS LOWER.
23.BATTERIES SHOULD NOT BE INSTALLED IN
DIRECT SUNLIGHT OR LOCATIONS
SUBJECTED TO WATER SPRAY.
SPRINKLERS SHOULD BE DIVERTED
WHEN NECESSARY.
24.BATTERIES CAN COMMUNICATE
WIRELESSLY OR VIA RS-485 TO INVERTER.
BATTERIES WITHIN 150' (IDEALLY 50') OF
RESPECTIVE INVERTER CAN USE
WIRELESS COMMUNICATIONS VIA SEDG
HOME NETWORK CARD.
25.COMBINED PV AND BESS OUTPUT POWER
IS LIMITED TO THE INVERTER AC RATING.
26.SOLAREDGE ENERGY BANK MAY BE
WALL, FLOOR, OR PAD MOUNTED
INDIVIDUALLY OR IN GROUPS OF (2), (3),
OR (4) UTILIZING THE SOLAREDGE FLOOR
MOUNT STAND. ENERGY BANK MEETS
THE UNIT LEVEL PERFORMANCE
CRITERIA OF UL 9540A, ALLOWING
ENERGY BANK TO BE STACKED FRONT TO
BACK AS LONG AS THE CLEARANCE
REQUIREMENTS ARE FOLLOWED TO
ALLOW FOR AIR FLOW AROUND THE
UNITS.
E401
G
BLDG
1401
GEC
E500
D
E401
G
BLDG
1401
GEC
E500
D
E401
G
BLDG
1401
GEC
E500
D
M
M
M
M
M FACILITY
LOADS
(E) TENANT
METERS (TYP.)
-
A
11101
UTILITY METER REFERENCE NUMBER:
222012-825599
SCE UTILITY GRID 240V, 1ø,3W
RMC ONLY
(N) LUGS ON (E)
HOLES
CUSTOMER
SECTION
UTILITY
SECTION
AHJ NOTES:
1.FUSED AC DISCONNECTS MUST BE SUSE RATED WITH A MAIN BONDING JUMPER
INSTALLED. CEC 230.82(6)
2.THE "GROUND" WIRE OF FUSED AC DISCONNECTS IS A GROUNDING ELECTRODE
CONDUCTOR TO BE BONDED TO THE GEC SYSTEM OF THE BUILDING
3.DISCONNECTS MUST BE WITHIN RMC TO THE POI. THE DISCONNECT AND THE
SUPPLY-SIDE POI MUST BE SEALED BY SCE. THIS IS CITY POLICY FOR SE
CONDUCTORS TO MINIMIZE POWER THEFT AND DAMAGE.
TO
GEC
EGCRMC ONLY
RMC ONLY
DISTANCE FROM FUSED
ACD TO POI ~ 10 FT
UTILITY TERMINATION
POI-5 AC WIRE SCHEDULE
LABEL DESTINATION NOMINAL VAC LINE SELECTION FLA FLAX1.25 OCPD PHASE
CONDUCTOR
NEUTRAL
CONDUCTOR
GROUNDING
CONDUCTOR
CONDUCTORS PER
PHASE
CONDUIT QTY 75°C AMPS 90°C AMPS 90°C AMPS W/
C.O.U
C.O.U TEMP
DERATE
C.O.U CONDUIT
FILL
CIRCUIT LENGTH ²SEGMENT VD%DC/AC RATIO AFC START AFC END ⁴EMT IMC PVC 40 PVC 80
INV-5.1 LC-5.1 240 A-B 47.5 59.4 60 CU #6 CU #10 CU #10 1 1 65 75 68.3 91%100%5 0.09%136.7%4,784 4,421 3/4"3/4"3/4"3/4"
INV-5.2 LC-5.1 240 A-B 31.7 39.6 40 CU #8 CU #10 CU #10 1 1 50 55 50.1 91%100%5 0.10%134.9%4,784 4,241 1/2"1/2"3/4"3/4"
INV-5.3 LC-5.1 240 A-B 31.7 39.6 40 CU #8 CU #10 CU #10 1 1 50 55 50.1 91%100%5 0.10%129.5%4,784 4,241 1/2"1/2"3/4"3/4"
LC-5.1 AC-5.2 240 A-B 110.8 138.5 150 CU #1/0 CU #6 CU #6 1 1 150 170 154.7 91%100%10 0.11%--5,008 4,784 1 1/4"1 1/4"1 1/4"1 1/4"
AC-5.2 AC-5.1 240 A-B 110.8 138.5 150 CU #1/0 CU #6 CU #6 1 1 150 170 154.7 91%100%10 0.11%--5,253 5,008 1 1/4"1 1/4"1 1/4"1 1/4"
AC-5.1 POI-5.5 240 A-B 110.8 138.5 150 CU #1/0 CU #1/0 CU #6 1 1 150 170 154.7 91%100%5 0.05%--42,000 35,115 1 1/2"1 1/4"1 1/2"1 1/2"
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
POI-5 ONE LINE
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
E604
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#ESTAMP
WILSHIRE MINNIE
1401 S MINNIE ST UNIT# MTR01
APN: 014-251-49
DEVELOPER:
C&C DEVELOPMENT
##KEYED NOTES#EQUIPMENT NOTES#
#
COMMUNICATION
CAT5E 600V RATED SHIELDED CABLE.
INSTALLER SHALL FOLLOW
MANUFACTURES RECOMMENDATION FOR
WIRE SIZING BASED ON LENGTH.
CIRCUIT IDENTIFIER
EQUIPMENT INDEX
EQUIPMENT TYPE
SYSTEM IDENTIFIER X INDICATES LETTERS
# INDICATES NUMBERS
XX-#.#
SYSTEM SUMMARY
15.20 ACKW | 22.96 DCKW | 21.39 CECKW
15.20 BESS ACKW | 58.20 BESS KWH
TOTAL FAULT CURRENTS
UTILITY: 42,000A | GENERATORS: 148A
DESCRIPTION OF OPERATION (DOO)
1.INVERTERS WITH ESS ARE CERTIFIED TO UL 1741 PCS CRD AND WILL HAVE
EXPORT-ONLY MODES ENABLED. THEY WILL UTILIZE EXCESS PV POWER TO CHARGE
THE BATTERIES AND THE BATTERIES WILL DISCHARGE DURING SET HOURS.
2.THE PRODUCER'S STORAGE DEVICE(S) WILL NOT CONSUME POWER FROM THE
DISTRIBUTION PROVIDER'S DISTRIBUTION SYSTEM AT ANY TIME.
3.GRID EXPORT IS ALLOWED THROUGH NEMV METER.
4.DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT
FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO
THE ACCEPTABLE MEASURE.
+-
18
14
1
13
14
ES-1
(3
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
6
.
1
.
A
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
ST
R
-
6
.
1
.
B
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
ES-2
DC-6.1.1
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4
A-B
40A
INV-6.1
+-
18
14
1
13
14
ES-1
(3
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
6
.
2
.
A
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
ST
R
-
6
.
2
.
B
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
ES-2
DC-6.2.2
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4
A-B
40A
INV-6.2
6
LC-6.1
6
8
5
(N) ACDS-2 SYSTEM AC DISCONNECT
SWITCH,, SQUARE D, VHU363RB, 600V RATED,
240V OPERATIONAL, 100A, 3 POLE,
NON-FUSIBLE, NEMA 3R. VISIBLE, LOCKABLE.
SEE REFERENCE SHEETS FOR KAIC RATING.
AC-6.2
M9
4
(N) SCE PV PRODUCTION METER SOCKET
ADDRESS: 1403 S MINNIE ST UNIT# MTR01,
COOPER B-LINE, 114TB, 100 A, SERVICE 1
PHASE 3 WIRE 120/240 VAC, NEMA 3R
AC-6.2
10
3
(N) ACDS-1 SYSTEM UTILITY AC DISCONNECT
SWITCH, SQUARE D, VH223NRB, 240V RATED,
240V OPERATIONAL, 100A, 2 POLE, FUSIBLE,
NEMA 3R, OR EQUIVALENT ON THE UTILITIES
APPROVED LIST. VISIBLE, LOCKABLE.
CLASS J FUSE, 200KAIC RATING.
A-B
80AAC-6.1
A INTERCONNECTION LOCATION
NTS1403 S MINNIE ST UNIT# MTR01
POI-6 DC STRING SCHEDULE
STR-A STR-B
TAG DESTINATION CIRCUIT LENGTH ²VD%MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES CIRCUIT LENGTH ²VD%MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES
DC-6.1.1 INV-6.1 75 0.71%410 14 U650 8 / 16¹80 0.71%410 14 U650 8 / 16¹
DC-6.2.2 INV-6.2 85 0.81%410 14 U650 8 / 16¹50 0.45%410 14 U650 8 / 16¹
¹ MAXIMUM STRING LENGTH IS USING MANUFACTURES EXCEPTION
² LENGTHS ARE ESTIMATED FOR CALCULATIONS, CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS AND TAKEOFFS
³ WHERE EXPOSED TO PHYSICAL DAMAGE #6 TO BE USED PER NEC 250.120(C)
⁴ AFC VALUES ARE CALCULATED BASED ON WIRE LENGTHS. LENGTHS SHOULD REMAIN GREATER THAN OR EQUAL TO THE LENGTH LISTED IN THE TABLE.
POI-6 DC WIRE SCHEDULE
TAG WIRE GAUGE CONDUCTOR
JACKET
MAX ISC 1.25 X MAX
CIRCUIT AMPS
CIRCUIT FUSE
RATING
CCC PER
CONDUIT
MAX AMBIENT
TEMP (C)
C.O.U TEMP.
DERATE
C.O.U CONDUIT
FILL DERATE
75°C AMPACITY COMPLIES WITH
690.8(B)(1)
90°C AMPACITY
WITH C.O.U
COMPLIES WITH
690.8(B)(2)
FAULT CURRENT
FROM PARALLEL
STRINGS
COMPLIES WITH
690.9(A)
GROUNDING
PER CONDUIT
GROUNDING ³EMT RMC PVC 40 PVC 80
DC-6.1.1 CU #10 THWN2 15 18.75 NONE 4 38 91%80%35 YES 29.1 YES 15 YES 2 CU #10 3/4"3/4"3/4"3/4"
DC-6.2.2 CU #10 THWN2 15 18.75 NONE 4 38 91%80%35 YES 29.1 YES 15 YES 2 CU #10 3/4"3/4"3/4"3/4"
LINE SIDE TAP VIA POLARIS TAPS
(POINT OF INTERCONNECTION)
SCE METER
1. PV MODULES (56) QCELLS NORTH
AMERICA Q.PEAK DUO BLK ML-G10.C+ 410
2. (56) SOLAREDGE DC OPTIMIZER U650
3. DC PV AND ESS CONNECTION UNIT W/
INTEGRAL LOAD BREAK DISCONNECT
4. (2) SOLAREDGE SE7600H-US HOME HUB
[240V] [SI1-SB] [CRD-PCS NEM], 7,600W,
240VAC, 1ø, 3W
5. (N) REVENUE GRADE METER, 1ø,
INTERGRATED RGM, W/ NOT REQUIRED
CTS
6. (1) LOAD CENTER, 100A, 1ø, MIN.240VAC,
MIN. 10KAIC, NEMA 3R
7. NOT USED
8.(N) ACDS-2 SYSTEM AC DISCONNECT
SWITCH, SQUARE D, VHU363RB, 600V
RATED, 240V OPERATIONAL, 100A, 3 POLE,
NON-FUSIBLE, NEMA 3R. SEE REFERENCE
SHEETS FOR KAIC RATING.
9. (N) SCE PV PRODUCTION METER SOCKET
ADDRESS: 1403 S MINNIE ST UNIT# MTR01,
COOPER B-LINE, 114TB, 100A, SERVICE: 1
PHASE 3 WIRE 120/240 VAC, # JAW, NEMA
3R, EUSERC: 304
10. (N) ACDS-1 SYSTEM UTILITY AC
DISCONNECT SWITCH, SQUARE D,
VH223NRB, 240V RATED, 240V
OPERATIONAL, 100A, 2 POLE, FUSIBLE,
NEMA 3R, OR EQUIVALENT ON THE
UTILITIES APPROVED LIST.
CLASS J FUSE, 200KAIC RATING.
11. (E) MAIN SERVICE EQUIPMENT: 1 PHASE 3
WIRE 120/240 VAC, 100A
12. (N) CELL-B-R05-US-S-S2 CELL CARD
13. (6) SOLAREDGE BAT-10K1P BATTERIES,
9.70KWH, 5,000DCW, NEMA 3R, MOUNTED
TO WALL OR MANUFACTURER FLOOR
MOUNT KIT
14. NOT USED
15. (N) POLARIS BLOCKS
16. NOT USED
1.(E) MAIN SWITCHGEAR AND (N) POINT OF
AC INTERCONNECTION. ALL
CONNECTIONS MADE INSIDE (E)
SWITCHGEAR AT OTHER THAN CIRCUIT
BREAKERS OR FUSED SWITCHES LISTED
FOR USE WITH THAT SWITCHGEAR SHALL
BE PERFORMED FOLLOWING
MANUFACTURERS INSTRUCTIONS OR BE
RE-LISTED BY A NRTL. ALL TERMINATIONS
OF ALUMINUM CONDUCTORS SHALL BE
WITH HIGH PRESS CRIMP LUGS ONLY.
WARNING LABEL DETAIL 1/E800
2.(E) UTILITY TENANT LOAD METER. UTILITY
REFERENCE METER NUMBER:
222013-048110
3.(N) PV SYSTEM UTILITY AC DISCONNECT
'ACDS-1'. WARNING LABEL DETAIL 1/E810
4.(N) UTILITY BIDIRECTIONAL KWH METER.
WARNING LABEL DETAIL 1/E810
5.(N) PV SYSTEM MAINTENANCE AC
DISCONNECT 'ACDS-2'. WARNING LABEL
DETAIL 2/E800 & 1/E810
6.NOT USED
7.(N) GRID-INTERACTIVE PV INVERTER
LISTED TO UL 1741 WITH GROUND FAULT
DETECTION & INTERRUPTION. WARNING
LABEL DETAIL 15/E800.
8.NOT USED
9.NOT USED
10.FOR SUPPLY SIDE CONNECTIONS, A
PLAQUE SHALL BE INSTALLED AT THE
MAIN SERVICE DISCONNECTING DEVICE
AND THE PV SYSTEM UTILITY AC
DISCONNECT INDICATING THE LOCATION
OF THE RESPECTIVE SERVICE
DISCONNECT. WARNING LABEL DETAIL
1/E800 & 1/E810
11.NOT USED
12.CONDUCTORS RUN IN PARALLEL SHALL
BE INSTALLED PER ART 310.4/310.10(G)
AND 250.122 (F).
13.NOT USED
14.NEW PULL/JUNCTION BOXES. PROVIDE
SERVICE LOOP IN ALL DC BRANCH
CONDUCTORS SOURCED FROM
ROOFTOPS, MIN LOOP RADIUS = 12X
CONDUCTOR DIAMETER.
15.NOT USED
16.(N) INVERTER INTERNAL DC DISCONNECT
SWITCH(ES). WARNING LABEL DETAIL
3/E800
17.NOT USED
18.(N) PV MODULE LISTED TO UL 1703.
19.EXTRA MODULES THAT ARE UNABLE TO
BE PAIRED WILL HAVE THEIR OWN
OPTIMIZER.
20.(N) COMMUNICATION WIRING TO FOLLOW
MANUFACTURING SPECIFICATIONS.
21.DURING UTILITY GRID OUTAGE THE PV
GENERATION AND BESS WILL
DISCONNECT FROM THE GRID AND
REMAIN DISCONNECTED UNTIL GRID
VOLTAGE IS RESTORED TO THE
ACCEPTED MEASURE.
22.BATTERY AC OUTPUT POWER IS LIMITED
TO THE CORRESPONDING INVERTER OR
TOTAL BATTERIES CONNECTED TO A
SINGLE INVERTER,WHICHEVER IS LOWER.
23.BATTERIES SHOULD NOT BE INSTALLED IN
DIRECT SUNLIGHT OR LOCATIONS
SUBJECTED TO WATER SPRAY.
SPRINKLERS SHOULD BE DIVERTED
WHEN NECESSARY.
24.BATTERIES CAN COMMUNICATE
WIRELESSLY OR VIA RS-485 TO INVERTER.
BATTERIES WITHIN 150' (IDEALLY 50') OF
RESPECTIVE INVERTER CAN USE
WIRELESS COMMUNICATIONS VIA SEDG
HOME NETWORK CARD.
25.COMBINED PV AND BESS OUTPUT POWER
IS LIMITED TO THE INVERTER AC RATING.
26.SOLAREDGE ENERGY BANK MAY BE
WALL, FLOOR, OR PAD MOUNTED
INDIVIDUALLY OR IN GROUPS OF (2), (3),
OR (4) UTILIZING THE SOLAREDGE FLOOR
MOUNT STAND. ENERGY BANK MEETS
THE UNIT LEVEL PERFORMANCE
CRITERIA OF UL 9540A, ALLOWING
ENERGY BANK TO BE STACKED FRONT TO
BACK AS LONG AS THE CLEARANCE
REQUIREMENTS ARE FOLLOWED TO
ALLOW FOR AIR FLOW AROUND THE
UNITS.
M
M
M
M
M FACILITY
LOADS
(E) TENANT
METERS (TYP.)
(N) POLARIS
BLOCK
-
A
11101
15
100A
UTILITY METER REFERENCE NUMBER:
222013-048110
SCE UTILITY GRID 240V, 1ø,3W
RMC ONLY
E401
G
BLDG
1403
GEC
E500
D
E401
G
BLDG
1403
GEC
E500
D
AHJ NOTES:
1.FUSED AC DISCONNECTS MUST BE SUSE RATED WITH A MAIN BONDING JUMPER
INSTALLED. CEC 230.82(6)
2.THE "GROUND" WIRE OF FUSED AC DISCONNECTS IS A GROUNDING ELECTRODE
CONDUCTOR TO BE BONDED TO THE GEC SYSTEM OF THE BUILDING
3.DISCONNECTS MUST BE WITHIN RMC TO THE POI. THE DISCONNECT AND THE
SUPPLY-SIDE POI MUST BE SEALED BY SCE. THIS IS CITY POLICY FOR SE
CONDUCTORS TO MINIMIZE POWER THEFT AND DAMAGE.
TO
GEC
EGCRMC ONLY
RMC ONLY
WEATHERHEAD - UTILITY
TERMINATION POINT
SCE CECTION
CUSTOMER
SECTION
DISTANCE FROM FUSED
ACD TO POI ~ 5 FT
UTILITY TERMINATION
POI-6 AC WIRE SCHEDULE
LABEL DESTINATION NOMINAL VAC LINE SELECTION FLA FLAX1.25 OCPD PHASE
CONDUCTOR
NEUTRAL
CONDUCTOR
GROUNDING
CONDUCTOR
CONDUCTORS PER
PHASE
CONDUIT QTY 75°C AMPS 90°C AMPS 90°C AMPS W/
C.O.U
C.O.U TEMP
DERATE
C.O.U CONDUIT
FILL
CIRCUIT LENGTH ²SEGMENT VD%DC/AC RATIO AFC START AFC END ⁴EMT IMC PVC 40 PVC 80
INV-6.1 LC-6.1 240 A-B 31.7 39.6 40 CU #8 CU #10 CU #10 1 1 50 55 50.1 91%100%5 0.10%151.1%2,851 2,649 1/2"1/2"3/4"3/4"
INV-6.2 LC-6.1 240 A-B 31.7 39.6 40 CU #8 CU #10 CU #10 1 1 50 55 50.1 91%100%5 0.10%151.1%2,851 2,649 1/2"1/2"3/4"3/4"
LC-6.1 AC-6.2 240 A-B 63.3 79.1 80 CU #4 CU #8 CU #8 1 1 85 95 86.5 91%100%10 0.16%--3,041 2,851 1"1"1"1"
AC-6.2 AC-6.1 240 A-B 63.3 79.1 80 CU #4 CU #8 CU #8 1 1 85 95 86.5 91%100%10 0.16%--3,258 3,041 1"1"1"1"
AC-6.1 POI-6.6 240 A-B 63.3 79.1 80 CU #4 CU #4 CU #8 1 1 85 95 86.5 91%100%5 0.08%--42,000 28,771 1"1"1"1 1/4"
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
POI-6 ONE LINE
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
E605
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#ESTAMP
WILSHIRE MINNIE
1403 S MINNIE ST UNIT# MTR01
APN: 014-251-49
DEVELOPER:
C&C DEVELOPMENT
##KEYED NOTES#EQUIPMENT NOTES#
#
COMMUNICATION
CAT5E 600V RATED SHIELDED CABLE.
INSTALLER SHALL FOLLOW
MANUFACTURES RECOMMENDATION FOR
WIRE SIZING BASED ON LENGTH.
CIRCUIT IDENTIFIER
EQUIPMENT INDEX
EQUIPMENT TYPE
SYSTEM IDENTIFIER X INDICATES LETTERS
# INDICATES NUMBERS
XX-#.#
SYSTEM SUMMARY
19.00 ACKW | 23.37 DCKW | 21.78 CECKW
19.00 BESS ACKW | 58.20 BESS KWH
TOTAL FAULT CURRENTS
UTILITY: 42,000A | GENERATORS: 148A
DESCRIPTION OF OPERATION (DOO)
1.INVERTERS WITH ESS ARE CERTIFIED TO UL 1741 PCS CRD AND WILL HAVE
EXPORT-ONLY MODES ENABLED. THEY WILL UTILIZE EXCESS PV POWER TO CHARGE
THE BATTERIES AND THE BATTERIES WILL DISCHARGE DURING SET HOURS.
2.THE PRODUCER'S STORAGE DEVICE(S) WILL NOT CONSUME POWER FROM THE
DISTRIBUTION PROVIDER'S DISTRIBUTION SYSTEM AT ANY TIME.
3.GRID EXPORT IS ALLOWED THROUGH NEMV METER.
4.DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT
FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO
THE ACCEPTABLE MEASURE.
+-
18
14
1
13
14
ES-1
(3
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
7
.
1
.
A
-
(
1
2
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
2
)
U
6
5
0
O
P
T
S
.
ST
R
-
7
.
1
.
B
-
(
1
1
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
1
)
U
6
5
0
O
P
T
S
.
ST
R
-
7
.
1
.
C
-
(
1
1
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
1
)
U
6
5
0
O
P
T
S
.
ES-2
DC-7.1.1
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4A
A-B
60A
INV-7.1
+-
18
14
1
13
14
ES-1
(3
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
7
.
2
.
A
-
(
1
2
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
2
)
U
6
5
0
O
P
T
S
.
ST
R
-
7
.
2
.
B
-
(
1
1
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
1
)
U
6
5
0
O
P
T
S
.
ES-2
DC-7.2.2
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4B
A-B
40A
INV-7.2
6
LC-7.1
6
8
5
(N) ACDS-2 SYSTEM AC DISCONNECT
SWITCH,, SQUARE D, VHU363RB, 600V RATED,
240V OPERATIONAL, 100A, 3 POLE,
NON-FUSIBLE, NEMA 3R. VISIBLE, LOCKABLE.
SEE REFERENCE SHEETS FOR KAIC RATING.
AC-7.2
M9
4
(N) SCE PV PRODUCTION METER SOCKET
ADDRESS: 1425 S MINNIE ST UNIT# MTR01,
COOPER B-LINE, 114TB, 100 A, SERVICE 1
PHASE 3 WIRE 120/240 VAC, NEMA 3R
AC-7.2
10
3
(N) ACDS-1 SYSTEM UTILITY AC DISCONNECT
SWITCH, SQUARE D, VH223NRB, 240V RATED,
240V OPERATIONAL, 100A, 2 POLE, FUSIBLE,
NEMA 3R, OR EQUIVALENT ON THE UTILITIES
APPROVED LIST. VISIBLE, LOCKABLE.
CLASS J FUSE, 200KAIC RATING.
A-B
100AAC-7.1
A INTERCONNECTION LOCATION
NTSAINTERCONNECTION LOCATION
NTS1425 S MINNIE ST UNIT# MTR01
POI-7 DC STRING SCHEDULE
STR-A STR-B STR-C
TAG DESTINATION CIRCUIT LENGTH ²VD%MODULE
WATTAGE
MODULE QTY OPTIMIZER MIN/MAX
MODULES
CIRCUIT LENGTH ²VD%MODULE
WATTAGE
MODULE QTY OPTIMIZER MIN/MAX
MODULES
CIRCUIT LENGTH ²VD%MODULE
WATTAGE
MODULE QTY OPTIMIZER MIN/MAX
MODULES
DC-7.1.1 INV-7.1 82 0.42%410 12 U650 8 / 16¹100 0.44%410 11 U650 8 / 16¹88 0.41%410 11 U650 8 / 16¹
DC-7.2.2 INV-7.2 60 0.49%410 12 U650 8 / 16¹60 0.42%410 11 U650 8 / 16¹------------
¹ MAXIMUM STRING LENGTH IS USING MANUFACTURES EXCEPTION
² LENGTHS ARE ESTIMATED FOR CALCULATIONS, CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS AND TAKEOFFS
³ WHERE EXPOSED TO PHYSICAL DAMAGE #6 TO BE USED PER NEC 250.120(C)
⁴ AFC VALUES ARE CALCULATED BASED ON WIRE LENGTHS. LENGTHS SHOULD REMAIN GREATER THAN OR EQUAL TO THE LENGTH LISTED IN THE TABLE.
POI-7 DC WIRE SCHEDULE
TAG WIRE GAUGE CONDUCTOR
JACKET
MAX ISC 1.25 X MAX
CIRCUIT AMPS
CIRCUIT FUSE
RATING
CCC PER
CONDUIT
MAX AMBIENT
TEMP (C)
C.O.U TEMP.
DERATE
C.O.U CONDUIT
FILL DERATE
75°C AMPACITY COMPLIES WITH
690.8(B)(1)
90°C AMPACITY
WITH C.O.U
COMPLIES WITH
690.8(B)(2)
FAULT CURRENT
FROM PARALLEL
STRINGS
COMPLIES WITH
690.9(A)
GROUNDING
PER CONDUIT
GROUNDING ³EMT RMC PVC 40 PVC 80
DC-7.1.1 CU #8 THWN2 15 18.75 NONE 6 38 91%80%50 YES 40.0 YES 30 YES 3 CU #10 1"1"1"1 1/4"
DC-7.2.2 CU #10 THWN2 15 18.75 NONE 4 38 91%80%35 YES 29.1 YES 15 YES 2 CU #10 3/4"3/4"3/4"3/4"
LINE SIDE TAP VIA POLARIS TAPS
(POINT OF INTERCONNECTION)
SCE METER
1. PV MODULES (57) QCELLS NORTH
AMERICA Q.PEAK DUO BLK ML-G10.C+ 410
2. (57) SOLAREDGE DC OPTIMIZER U650
3. DC PV AND ESS CONNECTION UNIT W/
INTEGRAL LOAD BREAK DISCONNECT
4. 4A: (1) SOLAREDGE SE11400H-US HOME
HUB [240V] [SI1-SB] [CRD-PCS NEM],
11,400W, 240VAC, 1ø, 3W
4B: (1) SOLAREDGE SE7600H-US HOME
HUB [240V] [SI1-SB] [CRD-PCS NEM],
7,600W, 240VAC, 1ø, 3W
5. (N) REVENUE GRADE METER, 1ø,
INTERGRATED RGM, W/ NOT REQUIRED
CTS
6. (1) LOAD CENTER, 100A, 1ø, MIN.240VAC,
MIN. 10KAIC, NEMA 3R
7. NOT USED
8.(N) ACDS-2 SYSTEM AC DISCONNECT
SWITCH, SQUARE D, VHU363RB, 600V
RATED, 240V OPERATIONAL, 100A, 3 POLE,
NON-FUSIBLE, NEMA 3R. SEE REFERENCE
SHEETS FOR KAIC RATING.
9. (N) SCE PV PRODUCTION METER SOCKET
ADDRESS: 1425 S MINNIE ST UNIT# MTR01,
COOPER B-LINE, 114TB, 100A, SERVICE: 1
PHASE 3 WIRE 120/240 VAC, # JAW, NEMA
3R, EUSERC: 304
10. (N) ACDS-1 SYSTEM UTILITY AC
DISCONNECT SWITCH, SQUARE D,
VH223NRB, 240V RATED, 240V
OPERATIONAL, 100A, 2 POLE, FUSIBLE,
NEMA 3R, OR EQUIVALENT ON THE
UTILITIES APPROVED LIST.
CLASS J FUSE, 200KAIC RATING.
11. (E) MAIN SERVICE EQUIPMENT: 1 PHASE 3
WIRE 120/240 VAC, 100A
12. (N) CELL-B-R05-US-S-S2 CELL CARD
13. (6) SOLAREDGE BAT-10K1P BATTERIES,
9.70KWH, 5,000DCW, NEMA 3R, MOUNTED
TO WALL OR MANUFACTURER FLOOR
MOUNT KIT
14. NOT USED
15. (N) POLARIS BLOCKS
16. NOT USED
1.(E) MAIN SWITCHGEAR AND (N) POINT OF
AC INTERCONNECTION. ALL
CONNECTIONS MADE INSIDE (E)
SWITCHGEAR AT OTHER THAN CIRCUIT
BREAKERS OR FUSED SWITCHES LISTED
FOR USE WITH THAT SWITCHGEAR SHALL
BE PERFORMED FOLLOWING
MANUFACTURERS INSTRUCTIONS OR BE
RE-LISTED BY A NRTL. ALL TERMINATIONS
OF ALUMINUM CONDUCTORS SHALL BE
WITH HIGH PRESS CRIMP LUGS ONLY.
WARNING LABEL DETAIL 1/E800
2.(E) UTILITY TENANT LOAD METER. UTILITY
REFERENCE METER NUMBER:
222013-124043
3.(N) PV SYSTEM UTILITY AC DISCONNECT
'ACDS-1'. WARNING LABEL DETAIL 1/E810
4.(N) UTILITY BIDIRECTIONAL KWH METER.
WARNING LABEL DETAIL 1/E810
5.(N) PV SYSTEM MAINTENANCE AC
DISCONNECT 'ACDS-2'. WARNING LABEL
DETAIL 2/E800 & 1/E810
6.NOT USED
7.(N) GRID-INTERACTIVE PV INVERTER
LISTED TO UL 1741 WITH GROUND FAULT
DETECTION & INTERRUPTION. WARNING
LABEL DETAIL 15/E800.
8.NOT USED
9.NOT USED
10.FOR SUPPLY SIDE CONNECTIONS, A
PLAQUE SHALL BE INSTALLED AT THE
MAIN SERVICE DISCONNECTING DEVICE
AND THE PV SYSTEM UTILITY AC
DISCONNECT INDICATING THE LOCATION
OF THE RESPECTIVE SERVICE
DISCONNECT. WARNING LABEL DETAIL
1/E800 & 1/E810
11.NOT USED
12.CONDUCTORS RUN IN PARALLEL SHALL
BE INSTALLED PER ART 310.4/310.10(G)
AND 250.122 (F).
13.NOT USED
14.NEW PULL/JUNCTION BOXES. PROVIDE
SERVICE LOOP IN ALL DC BRANCH
CONDUCTORS SOURCED FROM
ROOFTOPS, MIN LOOP RADIUS = 12X
CONDUCTOR DIAMETER.
15.NOT USED
16.(N) INVERTER INTERNAL DC DISCONNECT
SWITCH(ES). WARNING LABEL DETAIL
3/E800
17.NOT USED
18.(N) PV MODULE LISTED TO UL 1703.
19.EXTRA MODULES THAT ARE UNABLE TO
BE PAIRED WILL HAVE THEIR OWN
OPTIMIZER.
20.(N) COMMUNICATION WIRING TO FOLLOW
MANUFACTURING SPECIFICATIONS.
21.DURING UTILITY GRID OUTAGE THE PV
GENERATION AND BESS WILL
DISCONNECT FROM THE GRID AND
REMAIN DISCONNECTED UNTIL GRID
VOLTAGE IS RESTORED TO THE
ACCEPTED MEASURE.
22.BATTERY AC OUTPUT POWER IS LIMITED
TO THE CORRESPONDING INVERTER OR
TOTAL BATTERIES CONNECTED TO A
SINGLE INVERTER,WHICHEVER IS LOWER.
23.BATTERIES SHOULD NOT BE INSTALLED IN
DIRECT SUNLIGHT OR LOCATIONS
SUBJECTED TO WATER SPRAY.
SPRINKLERS SHOULD BE DIVERTED
WHEN NECESSARY.
24.BATTERIES CAN COMMUNICATE
WIRELESSLY OR VIA RS-485 TO INVERTER.
BATTERIES WITHIN 150' (IDEALLY 50') OF
RESPECTIVE INVERTER CAN USE
WIRELESS COMMUNICATIONS VIA SEDG
HOME NETWORK CARD.
25.COMBINED PV AND BESS OUTPUT POWER
IS LIMITED TO THE INVERTER AC RATING.
26.SOLAREDGE ENERGY BANK MAY BE
WALL, FLOOR, OR PAD MOUNTED
INDIVIDUALLY OR IN GROUPS OF (2), (3),
OR (4) UTILIZING THE SOLAREDGE FLOOR
MOUNT STAND. ENERGY BANK MEETS
THE UNIT LEVEL PERFORMANCE
CRITERIA OF UL 9540A, ALLOWING
ENERGY BANK TO BE STACKED FRONT TO
BACK AS LONG AS THE CLEARANCE
REQUIREMENTS ARE FOLLOWED TO
ALLOW FOR AIR FLOW AROUND THE
UNITS.
M
M
M
M
M FACILITY
LOADS
(E) TENANT
METERS (TYP.)
(N) POLARIS
BLOCK
-
A
11101
15
100A
UTILITY METER REFERENCE NUMBER:
222013-124043
SCE UTILITY GRID 240V, 1ø,3W
RMC ONLY
E401
G
BLDG
1425
GEC
E401
G
BLDG
1425
GEC
E500
D
E500
D
AHJ NOTES:
1.FUSED AC DISCONNECTS MUST BE SUSE RATED WITH A MAIN BONDING JUMPER
INSTALLED. CEC 230.82(6)
2.THE "GROUND" WIRE OF FUSED AC DISCONNECTS IS A GROUNDING ELECTRODE
CONDUCTOR TO BE BONDED TO THE GEC SYSTEM OF THE BUILDING
3.DISCONNECTS MUST BE WITHIN RMC TO THE POI. THE DISCONNECT AND THE
SUPPLY-SIDE POI MUST BE SEALED BY SCE. THIS IS CITY POLICY FOR SE
CONDUCTORS TO MINIMIZE POWER THEFT AND DAMAGE.
TO
GEC
EGCRMC ONLY
RMC ONLY
WEATHERHEAD - UTILITY
TERMINATION POINT
SCE CECTION
CUSTOMER
SECTION
DISTANCE FROM FUSED
ACD TO POI ~ 5 FT
UTILITY TERMINATION
POI-7 AC WIRE SCHEDULE
LABEL DESTINATION NOMINAL VAC LINE SELECTION FLA FLAX1.25 OCPD PHASE
CONDUCTOR
NEUTRAL
CONDUCTOR
GROUNDING
CONDUCTOR
CONDUCTORS PER
PHASE
CONDUIT QTY 75°C AMPS 90°C AMPS 90°C AMPS W/
C.O.U
C.O.U TEMP
DERATE
C.O.U CONDUIT
FILL
CIRCUIT LENGTH ²SEGMENT VD%DC/AC RATIO AFC START AFC END ⁴EMT IMC PVC 40 PVC 80
INV-7.1 LC-7.1 240 A-B 47.5 59.4 60 CU #6 CU #10 CU #10 1 1 65 75 68.3 91%100%5 0.09%122.3%3,542 3,339 3/4"3/4"3/4"3/4"
INV-7.2 LC-7.1 240 A-B 31.7 39.6 40 CU #8 CU #10 CU #10 1 1 50 55 50.1 91%100%5 0.10%124.1%3,542 3,235 1/2"1/2"3/4"3/4"
LC-7.1 AC-7.2 240 A-B 79.2 99.0 100 CU #3 CU #8 CU #8 1 1 100 115 104.7 91%100%10 0.16%--3,775 3,542 1"1"1"1"
AC-7.2 AC-7.1 240 A-B 79.2 99.0 100 CU #3 CU #8 CU #8 1 1 100 115 104.7 91%100%5 0.08%--3,904 3,775 1"1"1"1"
AC-7.1 POI-7.7 240 A-B 79.2 99.0 100 CU #3 CU #3 CU #8 1 1 100 115 104.7 91%100%5 0.08%--42,000 30,734 1"1"1"1 1/4"
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
POI-7 ONE LINE
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
E606
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#ESTAMP
WILSHIRE MINNIE
1425 S MINNIE ST UNIT# MTR01
APN: 014-251-50
DEVELOPER:
C&C DEVELOPMENT
##KEYED NOTES#EQUIPMENT NOTES#
A INTERCONNECTION LOCATION
NTS
COMMUNICATION
CIRCUIT IDENTIFIER
##KEYED NOTES#EQUIPMENT NOTES#
A INTERCONNECTION LOCATION
NTS
COMMUNICATION
CIRCUIT IDENTIFIER
SYSTEM SUMMARY
15.20 ACKW | 22.14 DCKW | 20.63 CECKW
15.20 BESS ACKW | 58.20 BESS KWH
TOTAL FAULT CURRENTS
UTILITY: 42,000A | GENERATORS: 156.2A
+ -18
14
1 13
14
ES-1
(3
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
8
.
1
.
A
-
(
1
3
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
3
)
U
6
5
0
O
P
T
S
.
ST
R
-
8
.
1
.
B
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
ES-2
DC-8.1.1
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4
A-B
40A
INV-8.1
+ -18
14
1 13
14
ES-1
(3
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
8
.
2
.
A
-
(
1
3
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
3
)
U
6
5
0
O
P
T
S
.
ST
R
-
8
.
2
.
B
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
ES-2
DC-8.2.2
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4
A-B
40A
INV-8.2
6
LC-8.1
6
8
5 (N) ACDS-2 SYSTEM AC DISCONNECT
SWITCH,, SQUARE D, VHU363RB, 600V RATED,
240V OPERATIONAL, 100A, 3 POLE,
NON-FUSIBLE, NEMA 3R. SEE REFERENCE
SHEETS FOR KAIC RATING.
AC-8.2
M9
4
(N) SCE PV PRODUCTION METER SOCKET
ADDRESS: 1235 E WILSHIRE AVE BLDG 1413
SOMAH8, COOPER B-LINE, 114TB, 100 A,
SERVICE 1 PHASE 3 WIRE 120/240 VAC, NEMA
3R
AC-8.2
10
3
(N) ACDS-1 SYSTEM UTILITY AC DISCONNECT
SWITCH, SQUARE D, VH223NRB, 240V RATED,
240V OPERATIONAL, 100A, 2 POLE, FUSIBLE,
NEMA 3R, OR EQUIVALENT ON THE UTILITIES
APPROVED LIST. CLASS R FUSE WITH
REJECTION CLIPS OR CLASS J FOR 200KAIC
RATING.
A-B
80AAC-8.1
1. PV MODULES (54) QCELLS NORTH
AMERICA Q.PEAK DUO BLK ML-G10.C+ 410
2. (54) SOLAREDGE DC OPTIMIZER U650
3. DC PV AND ESS CONNECTION UNIT W/
INTEGRAL LOAD BREAK DISCONNECT
4. (2) SOLAREDGE SE7600H-US HOME HUB
[SI1-SB], 7,600W, 240VAC, 1ø, 3W
5. (N) REVENUE GRADE METER, 1ø,
INTERGRATED RGM, W/ NOT REQUIRED
CTS
6. (1) LOAD CENTER, 100A, 1ø, MIN.240VAC,
MIN. 22KAIC, NEMA 3R
7. NOT USED
8. (N) ACDS-2 SYSTEM AC DISCONNECT
SWITCH, SQUARE D, VHU363RB, 600V
RATED, 240V OPERATIONAL, 100A, 3 POLE,
NON-FUSIBLE, NEMA 3R. SEE REFERENCE
SHEETS FOR KAIC RATING.
9. (N) SCE PV PRODUCTION METER SOCKET
ADDRESS: 1235 E WILSHIRE AVE BLDG
1413 SOMAH8, COOPER B-LINE, 114TB,
100A, SERVICE: 1 PHASE 3 WIRE 120/240
VAC, # JAW, NEMA 3R, EUSERC: 304
10. (N) ACDS-1 SYSTEM UTILITY AC
DISCONNECT SWITCH, SQUARE D,
VH223NRB, 240V RATED, 240V
OPERATIONAL, 100A, 2 POLE, FUSIBLE,
NEMA 3R, OR EQUIVALENT ON THE
UTILITIES APPROVED LIST. CLASS R FUSE
WITH REJECTION CLIPS OR CLASS J FOR
200KAIC RATING.
11. (E) MAIN SERVICE EQUIPMENT: 1 PHASE 3
WIRE 120/240 VAC, 100A
12. MANUFACTURER INTERGRATED CELL
CARD
13. (6) SOLAREDGE BAT-10K1P BATTERIES,
9.70KWH, 5,000DCW, NEMA 3R, MOUNTED
TO WALL OR MANUFACTURER FLOOR
MOUNT KIT
14. NOT USED
15. (N) POLARIS BLOCKS
16. NOT USED
1. (E) MAIN SWITCHGEAR AND (N) POINT OF
AC INTERCONNECTION. ALL
CONNECTIONS MADE INSIDE (E)
SWITCHGEAR AT OTHER THAN CIRCUIT
BREAKERS OR FUSED SWITCHES LISTED
FOR USE WITH THAT SWITCHGEAR SHALL
BE PERFORMED FOLLOWING
MANUFACTURERS INSTRUCTIONS OR BE
RE-LISTED BY A NRTL. ALL TERMINATIONS
OF ALUMINUM CONDUCTORS SHALL BE
WITH HIGH PRESS CRIMP LUGS ONLY.
WARNING LABEL DETAIL 1/E800
2. (E) UTILITY TENANT LOAD METER. UTILITY
REFERENCE METER NUMBER:
222013-048131
3. (N) PV SYSTEM UTILITY AC DISCONNECT
'ACDS-1'. WARNING LABEL DETAIL 1/E810
4. (N) UTILITY BIDIRECTIONAL KWH METER.
WARNING LABEL DETAIL 1/E810
5. (N) PV SYSTEM MAINTENANCE AC
DISCONNECT 'ACDS-2'. WARNING LABEL
DETAIL 2/E800 & 1/E810
6. NOT USED
7. (N) GRID-INTERACTIVE PV INVERTER
LISTED TO UL 1741 WITH GROUND FAULT
DETECTION & INTERRUPTION. WARNING
LABEL DETAIL 15/E800.
8. NOT USED
9. NOT USED
10. FOR SUPPLY SIDE CONNECTIONS, A
PLAQUE SHALL BE INSTALLED AT THE
MAIN SERVICE DISCONNECTING DEVICE
AND THE PV SYSTEM UTILITY AC
DISCONNECT INDICATING THE LOCATION
OF THE RESPECTIVE SERVICE
DISCONNECT. WARNING LABEL DETAIL
1/E800 & 1/E810
11. NOT USED
12. CONDUCTORS RUN IN PARALLEL SHALL
BE INSTALLED PER ART 310.4/310.10(G)
AND 250.122 (F).
13. NOT USED
14. NEW PULL/JUNCTION BOXES. PROVIDE
SERVICE LOOP IN ALL DC BRANCH
CONDUCTORS SOURCED FROM
ROOFTOPS, MIN LOOP RADIUS = 12X
CONDUCTOR DIAMETER.
15. NOT USED
16. (N) INVERTER INTERNAL DC DISCONNECT
SWITCH(ES). WARNING LABEL DETAIL
3/E800
17. NOT USED
18. (N) PV MODULE LISTED TO UL 1703.
19. EXTRA MODULES THAT ARE UNABLE TO
BE PAIRED WILL HAVE THEIR OWN
OPTIMIZER.
20. (N) COMMUNICATION WIRING TO FOLLOW
MANUFACTURING SPECIFICATIONS.
21. DURING UTILITY GRID OUTAGE THE PV
GENERATION AND BESS WILL
DISCONNECT FROM THE GRID AND
REMAIN DISCONNECTED UNTIL GRID
VOLTAGE IS RESTORED TO THE
ACCEPTED MEASURE.
22. BATTERY AC OUTPUT POWER IS LIMITED
TO THE CORRESPONDING INVERTER OR
TOTAL BATTERIES CONNECTED TO A
SINGLE INVERTER,WHICHEVER IS LOWER.
23. BATTERIES SHOULD NOT BE INSTALLED IN
DIRECT SUNLIGHT OR LOCATIONS
SUBJECTED TO WATER SPRAY.
SPRINKLERS SHOULD BE DIVERTED
WHEN NECESSARY.
24. BATTERIES CAN COMMUNICATE
WIRELESSLY OR VIA RS-485 TO INVERTER.
BATTERIES WITHIN 150' (IDEALLY 50') OF
RESPECTIVE INVERTER CAN USE
WIRELESS COMMUNICATIONS VIA SEDG
HOME NETWORK CARD.
25. COMBINED PV AND BESS OUTPUT POWER
IS LIMITED TO THE INVERTER AC RATING.
26. NOT USED
#
CAT5E 600V RATED SHIELDED CABLE.
INSTALLER SHALL FOLLOW
MANUFACTURES RECOMMENDATION FOR
WIRE SIZING BASED ON LENGTH.
EQUIPMENT TYPE
SYSTEM IDENTIFIER X INDICATES LETTERS
# INDICATES NUMBERS
XX-#.#
1235 E WILSHIRE AVE BLDG 1413 SOMAH8
POI-8 DC STRING SCHEDULE
STR-A STR-B
TAG DESTINATION CIRCUIT LENGTH ²VD% MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES CIRCUIT LENGTH ²VD% MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES
DC-8.1.1 INV-8.1 120 1.06%410 13 U650 8 / 16¹50 0.45%410 14 U650 8 / 16¹
DC-8.2.2 INV-8.2 95 0.84%410 13 U650 8 / 16¹95 0.85%410 14 U650 8 / 16¹
¹ MAXIMUM STRING LENGTH IS USING MANUFACTURES EXCEPTION
² LENGTHS ARE ESTIMATED FOR CALCULATIONS, CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS AND TAKEOFFS
³ WHERE EXPOSED TO PHYSICAL DAMAGE #6 TO BE USED PER NEC 250.120(C)
⁴ AFC VALUES ARE CALCULATED BASED ON WIRE LENGTHS. LENGTHS SHOULD REMAIN GREATER THAN OR EQUAL TO THE LENGTH LISTED IN THE TABLE.
POI-8 DC WIRE SCHEDULE
TAG WIRE GAUGE CONDUCTOR JACKET CCC PER CONDUIT GROUNDING ³EMT RMC PVC 40 PVC 80
DC-8.1.1 CU #10 THWN2 4 CU #10 3/4"3/4"3/4"3/4"
DC-8.2.2 CU #10 THWN2 4 CU #10 3/4"3/4"3/4"3/4"
POI-8 AC WIRE SCHEDULE
LABEL DESTINATION NOMINAL VAC LINE
SELECTION
FLA FLAX1.25 PHASE
CONDUCTOR
NEUTRAL
CONDUCTOR
GROUNDING
CONDUCTOR
CONDUCTORS
PER PHASE
CONDUIT QTY CIRCUIT
LENGTH ²
SEGMENT
VD%
DC/AC RATIO AFC START AFC END ⁴EMT IMC PVC 40 PVC 80
INV-8.1 LC-8.1 240 A-B 31.7 39.6 CU #8 CU #10 CU #10 1 1 5 0.10% 145.7%4,918 4,346 1/2"1/2"3/4"3/4"
INV-8.2 LC-8.1 240 A-B 31.7 39.6 CU #8 CU #10 CU #10 1 1 5 0.10% 145.7%4,918 4,346 1/2"1/2"3/4"3/4"
LC-8.1 AC-8.2 240 A-B 63.3 79.1 CU #4 CU #8 CU #8 1 1 70 1.10%--19,967 4,918 1"1"1"1"
AC-8.2 AC-8.1 240 A-B 63.3 79.1 CU #4 CU #8 CU #8 1 1 7 0.11%--28,771 19,967 1"1"1"1"
AC-8.1 POI-8.8 240 A-B 63.3 79.1 CU #4 CU #4 CU #8 1 1 5 0.08%--42,000 28,771 1"1"1"1 1/4"
M
M
M
M
M FACILITY
LOADS
(N) TENANT
METERS (TYP.)
UTILITY METER REFERENCE NUMBER:
222013-048131
SCE UTILITY GRID 240V,
1ø,3W
11101
-
A
15
(N) POLARIS
BLOCK
POLARIS SUPPLY SIDE TAP
POINT OF INTERCONNECTION
C:\USERS\EMILIANO.MORALES\DESKTOP\WORKING PROJECTS\1235_WILSHIRE_MINNIE\CD100\WILSHIRE MINNIE_WORKINGDOCS_V0\WILSHIRE MINNIE.DWG
POI-8 ONE LINE
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
PROJECT DETAILS:
PV SYSTEM:
·355.88 kW DC
·250.8 kW AC
·331.612 CEC AC
ENERGY STORAGE:
·243.2 kW AC
·756.6 kWH
E607
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER: FINS_TM
ORIGINAL
CONTRACT NUMBER:
3003197607
PJT #: PROP-001235
##KEYED NOTES#EQUIPMENT NOTES#
A INTERCONNECTION LOCATION
NTS
COMMUNICATION
CIRCUIT IDENTIFIER
##KEYED NOTES#EQUIPMENT NOTES#
A INTERCONNECTION LOCATION
NTS
COMMUNICATION
CIRCUIT IDENTIFIER
SYSTEM SUMMARY
15.20 ACKW | 21.73 DCKW | 20.25 CECKW
15.20 BESS ACKW | 58.20 BESS KWH
TOTAL FAULT CURRENTS
UTILITY: 42,000A | GENERATORS: 156.2A
+ -18
14
1 13
14
ES-1
(3
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
9
.
1
.
A
-
(
1
2
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
2
)
U
6
5
0
O
P
T
S
.
ST
R
-
9
.
1
.
B
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
ES-2
DC-9.1.1
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4
A-B
40A
INV-9.1
+ -18
14
1 13
14
ES-1
(3
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
9
.
2
.
A
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
ST
R
-
9
.
2
.
B
-
(
1
3
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
3
)
U
6
5
0
O
P
T
S
.
ES-2
DC-9.2.2
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4
A-B
40A
INV-9.2
6
LC-9.1
6
8
5 (N) ACDS-2 SYSTEM AC DISCONNECT
SWITCH,, SQUARE D, VHU363RB, 600V RATED,
240V OPERATIONAL, 100A, 3 POLE,
NON-FUSIBLE, NEMA 3R. SEE REFERENCE
SHEETS FOR KAIC RATING.
AC-9.2
M9
4
(N) SCE PV PRODUCTION METER SOCKET
ADDRESS: 1235 E WILSHIRE AVE BLDG 1421
SOMAH9, COOPER B-LINE, 114TB, 100 A,
SERVICE 1 PHASE 3 WIRE 120/240 VAC, NEMA
3R
AC-9.2
10
3
(N) ACDS-1 SYSTEM UTILITY AC DISCONNECT
SWITCH, SQUARE D, VH223NRB, 240V RATED,
240V OPERATIONAL, 100A, 2 POLE, FUSIBLE,
NEMA 3R, OR EQUIVALENT ON THE UTILITIES
APPROVED LIST. CLASS R FUSE WITH
REJECTION CLIPS OR CLASS J FOR 200KAIC
RATING.
A-B
80AAC-9.1
1. PV MODULES (53) QCELLS NORTH
AMERICA Q.PEAK DUO BLK ML-G10.C+ 410
2. (53) SOLAREDGE DC OPTIMIZER U650
3. DC PV AND ESS CONNECTION UNIT W/
INTEGRAL LOAD BREAK DISCONNECT
4. (2) SOLAREDGE SE7600H-US HOME HUB
[SI1-SB], 7,600W, 240VAC, 1ø, 3W
5. (N) REVENUE GRADE METER, 1ø,
INTERGRATED RGM, W/ NOT REQUIRED
CTS
6. (1) LOAD CENTER, 100A, 1ø, MIN.240VAC,
MIN. 22KAIC, NEMA 3R
7. NOT USED
8. (N) ACDS-2 SYSTEM AC DISCONNECT
SWITCH, SQUARE D, VHU363RB, 600V
RATED, 240V OPERATIONAL, 100A, 3 POLE,
NON-FUSIBLE, NEMA 3R. SEE REFERENCE
SHEETS FOR KAIC RATING.
9. (N) SCE PV PRODUCTION METER SOCKET
ADDRESS: 1235 E WILSHIRE AVE BLDG
1421 SOMAH9, COOPER B-LINE, 114TB,
100A, SERVICE: 1 PHASE 3 WIRE 120/240
VAC, # JAW, NEMA 3R, EUSERC: 304
10. (N) ACDS-1 SYSTEM UTILITY AC
DISCONNECT SWITCH, SQUARE D,
VH223NRB, 240V RATED, 240V
OPERATIONAL, 100A, 2 POLE, FUSIBLE,
NEMA 3R, OR EQUIVALENT ON THE
UTILITIES APPROVED LIST. CLASS R FUSE
WITH REJECTION CLIPS OR CLASS J FOR
200KAIC RATING.
11. (E) MAIN SERVICE EQUIPMENT: 1 PHASE 3
WIRE 120/240 VAC, 100A
12. MANUFACTURER INTERGRATED CELL
CARD
13. (6) SOLAREDGE BAT-10K1P BATTERIES,
9.70KWH, 5,000DCW, NEMA 3R, MOUNTED
TO WALL OR MANUFACTURER FLOOR
MOUNT KIT
14. NOT USED
15. (N) POLARIS BLOCKS
16. NOT USED
1. (E) MAIN SWITCHGEAR AND (N) POINT OF
AC INTERCONNECTION. ALL
CONNECTIONS MADE INSIDE (E)
SWITCHGEAR AT OTHER THAN CIRCUIT
BREAKERS OR FUSED SWITCHES LISTED
FOR USE WITH THAT SWITCHGEAR SHALL
BE PERFORMED FOLLOWING
MANUFACTURERS INSTRUCTIONS OR BE
RE-LISTED BY A NRTL. ALL TERMINATIONS
OF ALUMINUM CONDUCTORS SHALL BE
WITH HIGH PRESS CRIMP LUGS ONLY.
WARNING LABEL DETAIL 1/E800
2. (E) UTILITY TENANT LOAD METER. UTILITY
REFERENCE METER NUMBER:
222013-048104
3. (N) PV SYSTEM UTILITY AC DISCONNECT
'ACDS-1'. WARNING LABEL DETAIL 1/E810
4. (N) UTILITY BIDIRECTIONAL KWH METER.
WARNING LABEL DETAIL 1/E810
5. (N) PV SYSTEM MAINTENANCE AC
DISCONNECT 'ACDS-2'. WARNING LABEL
DETAIL 2/E800 & 1/E810
6. NOT USED
7. (N) GRID-INTERACTIVE PV INVERTER
LISTED TO UL 1741 WITH GROUND FAULT
DETECTION & INTERRUPTION. WARNING
LABEL DETAIL 15/E800.
8. NOT USED
9. NOT USED
10. FOR SUPPLY SIDE CONNECTIONS, A
PLAQUE SHALL BE INSTALLED AT THE
MAIN SERVICE DISCONNECTING DEVICE
AND THE PV SYSTEM UTILITY AC
DISCONNECT INDICATING THE LOCATION
OF THE RESPECTIVE SERVICE
DISCONNECT. WARNING LABEL DETAIL
1/E800 & 1/E810
11. NOT USED
12. CONDUCTORS RUN IN PARALLEL SHALL
BE INSTALLED PER ART 310.4/310.10(G)
AND 250.122 (F).
13. NOT USED
14. NEW PULL/JUNCTION BOXES. PROVIDE
SERVICE LOOP IN ALL DC BRANCH
CONDUCTORS SOURCED FROM
ROOFTOPS, MIN LOOP RADIUS = 12X
CONDUCTOR DIAMETER.
15. NOT USED
16. (N) INVERTER INTERNAL DC DISCONNECT
SWITCH(ES). WARNING LABEL DETAIL
3/E800
17. NOT USED
18. (N) PV MODULE LISTED TO UL 1703.
19. EXTRA MODULES THAT ARE UNABLE TO
BE PAIRED WILL HAVE THEIR OWN
OPTIMIZER.
20. (N) COMMUNICATION WIRING TO FOLLOW
MANUFACTURING SPECIFICATIONS.
21. DURING UTILITY GRID OUTAGE THE PV
GENERATION AND BESS WILL
DISCONNECT FROM THE GRID AND
REMAIN DISCONNECTED UNTIL GRID
VOLTAGE IS RESTORED TO THE
ACCEPTED MEASURE.
22. BATTERY AC OUTPUT POWER IS LIMITED
TO THE CORRESPONDING INVERTER OR
TOTAL BATTERIES CONNECTED TO A
SINGLE INVERTER,WHICHEVER IS LOWER.
23. BATTERIES SHOULD NOT BE INSTALLED IN
DIRECT SUNLIGHT OR LOCATIONS
SUBJECTED TO WATER SPRAY.
SPRINKLERS SHOULD BE DIVERTED
WHEN NECESSARY.
24. BATTERIES CAN COMMUNICATE
WIRELESSLY OR VIA RS-485 TO INVERTER.
BATTERIES WITHIN 150' (IDEALLY 50') OF
RESPECTIVE INVERTER CAN USE
WIRELESS COMMUNICATIONS VIA SEDG
HOME NETWORK CARD.
25. COMBINED PV AND BESS OUTPUT POWER
IS LIMITED TO THE INVERTER AC RATING.
26. NOT USED
#
CAT5E 600V RATED SHIELDED CABLE.
INSTALLER SHALL FOLLOW
MANUFACTURES RECOMMENDATION FOR
WIRE SIZING BASED ON LENGTH.
EQUIPMENT TYPE
SYSTEM IDENTIFIER X INDICATES LETTERS
# INDICATES NUMBERS
XX-#.#
1235 E WILSHIRE AVE BLDG 1421 SOMAH9
POI-9 DC STRING SCHEDULE
STR-A STR-B
TAG DESTINATION CIRCUIT LENGTH ²VD% MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES CIRCUIT LENGTH ²VD% MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES
DC-9.1.1 INV-9.1 105 0.85%410 12 U650 8 / 16¹95 0.85%410 14 U650 8 / 16¹
DC-9.2.2 INV-9.2 50 0.47%410 14 U650 8 / 16¹60 0.50%410 13 U650 8 / 16¹
¹ MAXIMUM STRING LENGTH IS USING MANUFACTURES EXCEPTION
² LENGTHS ARE ESTIMATED FOR CALCULATIONS, CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS AND TAKEOFFS
³ WHERE EXPOSED TO PHYSICAL DAMAGE #6 TO BE USED PER NEC 250.120(C)
⁴ AFC VALUES ARE CALCULATED BASED ON WIRE LENGTHS. LENGTHS SHOULD REMAIN GREATER THAN OR EQUAL TO THE LENGTH LISTED IN THE TABLE.
POI-9 DC WIRE SCHEDULE
TAG WIRE GAUGE CONDUCTOR JACKET CCC PER CONDUIT GROUNDING ³EMT RMC PVC 40 PVC 80
DC-9.1.1 CU #10 THWN2 4 CU #10 3/4"3/4"3/4"3/4"
DC-9.2.2 CU #10 THWN2 4 CU #10 3/4"3/4"3/4"3/4"
POI-9 AC WIRE SCHEDULE
LABEL DESTINATION NOMINAL VAC LINE
SELECTION
FLA FLAX1.25 PHASE
CONDUCTOR
NEUTRAL
CONDUCTOR
GROUNDING
CONDUCTOR
CONDUCTORS
PER PHASE
CONDUIT QTY CIRCUIT
LENGTH ²
SEGMENT
VD%
DC/AC RATIO AFC START AFC END ⁴EMT IMC PVC 40 PVC 80
INV-9.1 LC-9.1 240 A-B 31.7 39.6 CU #8 CU #10 CU #10 1 1 5 0.10% 140.3%4,764 4,225 1/2"1/2"3/4"3/4"
INV-9.2 LC-9.1 240 A-B 31.7 39.6 CU #8 CU #10 CU #10 1 1 5 0.10% 145.7%4,764 4,225 1/2"1/2"3/4"3/4"
LC-9.1 AC-9.2 240 A-B 63.3 79.1 CU #4 CU #8 CU #8 1 1 75 1.18%--21,880 4,764 1"1"1"1"
AC-9.2 AC-9.1 240 A-B 63.3 79.1 CU #4 CU #8 CU #8 1 1 5 0.08%--28,771 21,880 1"1"1"1"
AC-9.1 POI-9.9 240 A-B 63.3 79.1 CU #4 CU #4 CU #8 1 1 5 0.08%--42,000 28,771 1"1"1"1 1/4"
M
M
M
M
M FACILITY
LOADS
(N) TENANT
METERS (TYP.)
UTILITY METER REFERENCE NUMBER:
222013-048104
SCE UTILITY GRID 240V,
1ø,3W
11101
-
A
15
(N) POLARIS
BLOCK
POLARIS SUPPLY SIDE TAP
POINT OF INTERCONNECTION
C:\USERS\EMILIANO.MORALES\DESKTOP\WORKING PROJECTS\1235_WILSHIRE_MINNIE\CD100\WILSHIRE MINNIE_WORKINGDOCS_V0\WILSHIRE MINNIE.DWG
POI-8 ONE LINE
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
PROJECT DETAILS:
PV SYSTEM:
·355.88 kW DC
·250.8 kW AC
·331.612 CEC AC
ENERGY STORAGE:
·243.2 kW AC
·756.6 kWH
E608
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER: FINS_TM
ORIGINAL
CONTRACT NUMBER:
3003197607
PJT #: PROP-001235
##KEYED NOTES#EQUIPMENT NOTES#
A INTERCONNECTION LOCATION
NTS
COMMUNICATION
CIRCUIT IDENTIFIER
##KEYED NOTES#EQUIPMENT NOTES#
A INTERCONNECTION LOCATION
NTS
COMMUNICATION
CIRCUIT IDENTIFIER
SYSTEM SUMMARY
19.00 ACKW | 27.88 DCKW | 25.98 CECKW
19.00 BESS ACKW | 58.20 BESS KWH
TOTAL FAULT CURRENTS
UTILITY: 42,000A | GENERATORS: 156.2A
+ -18
14
1 13
14
ES-1
(3
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
1
0
.
1
.
A
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
ST
R
-
1
0
.
1
.
B
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
ST
R
-
1
0
.
1
.
C
-
(
1
4
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
4
)
U
6
5
0
O
P
T
S
.
ES-2
DC-10.1.1
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4A
A-B
60A
INV-10.1
+ -18
14
1 13
14
ES-1
(3
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
1
0
.
2
.
A
-
(
8
)
4
1
0
W
M
O
D
U
L
E
W
/
(
8
)
U
6
5
0
O
P
T
S
.
ST
R
-
1
0
.
2
.
B
-
(
8
)
4
1
0
W
M
O
D
U
L
E
W
/
(
8
)
U
6
5
0
O
P
T
S
.
ST
R
-
1
0
.
2
.
C
-
(
1
0
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
0
)
U
6
5
0
O
P
T
S
.
ES-2
DC-10.2.2
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4B
A-B
40A
INV-10.2
6
LC-10.1
6
8
5 (N) ACDS-2 SYSTEM AC DISCONNECT
SWITCH,, SQUARE D, VHU362RB, 600V RATED,
240V OPERATIONAL, 60A, 3 POLE,
NON-FUSIBLE, NEMA 3R. SEE REFERENCE
SHEETS FOR KAIC RATING.
AC-10.2
M9
4
(N) SCE PV PRODUCTION METER SOCKET
ADDRESS: 1235 E WILSHIRE AVE BLDG 1425
SOMAH10, COOPER B-LINE, 114TB, 100 A,
SERVICE 1 PHASE 3 WIRE 120/240 VAC, NEMA
3R
AC-10.2
10
3
(N) ACDS-1 SYSTEM UTILITY AC DISCONNECT
SWITCH, SQUARE D, VH223NRB, 240V RATED,
240V OPERATIONAL, 100A, 2 POLE, FUSIBLE,
NEMA 3R, OR EQUIVALENT ON THE UTILITIES
APPROVED LIST. CLASS R FUSE WITH
REJECTION CLIPS OR CLASS J FOR 200KAIC
RATING.
A-B
100AAC-10.1
1. PV MODULES (68) QCELLS NORTH
AMERICA Q.PEAK DUO BLK ML-G10.C+ 410
2. (68) SOLAREDGE DC OPTIMIZER U650
3. DC PV AND ESS CONNECTION UNIT W/
INTEGRAL LOAD BREAK DISCONNECT
4. 4A: (1) SOLAREDGE SE11400H-US HOME
HUB [SI1-SB], 11,400W, 240VAC, 1ø, 3W
4B: (1) SOLAREDGE SE7600H-US HOME
HUB [SI1-SB], 7,600W, 240VAC, 1ø, 3W
5. (N) REVENUE GRADE METER, 1ø,
INTERGRATED RGM, W/ NOT REQUIRED
CTS
6. (1) LOAD CENTER, 100A, 1ø, MIN.240VAC,
MIN. 22KAIC, NEMA 3R
7. NOT USED
8. (N) ACDS-2 SYSTEM AC DISCONNECT
SWITCH, SQUARE D, VHU362RB, 600V
RATED, 240V OPERATIONAL, 60A, 3 POLE,
NON-FUSIBLE, NEMA 3R. SEE REFERENCE
SHEETS FOR KAIC RATING.
9. (N) SCE PV PRODUCTION METER SOCKET
ADDRESS: 1235 E WILSHIRE AVE BLDG
1425 SOMAH10, COOPER B-LINE, 114TB,
100A, SERVICE: 1 PHASE 3 WIRE 120/240
VAC, # JAW, NEMA 3R, EUSERC: 304
10. (N) ACDS-1 SYSTEM UTILITY AC
DISCONNECT SWITCH, SQUARE D,
VH223NRB, 240V RATED, 240V
OPERATIONAL, 100A, 2 POLE, FUSIBLE,
NEMA 3R, OR EQUIVALENT ON THE
UTILITIES APPROVED LIST. CLASS R FUSE
WITH REJECTION CLIPS OR CLASS J FOR
200KAIC RATING.
11. (E) MAIN SERVICE EQUIPMENT: 1 PHASE 3
WIRE 120/240 VAC, 100A
12. MANUFACTURER INTERGRATED CELL
CARD
13. (6) SOLAREDGE BAT-10K1P BATTERIES,
9.70KWH, 5,000DCW, NEMA 3R, MOUNTED
TO WALL OR MANUFACTURER FLOOR
MOUNT KIT
14. NOT USED
15. (N) POLARIS BLOCKS
16. NOT USED
1. (E) MAIN SWITCHGEAR AND (N) POINT OF
AC INTERCONNECTION. ALL
CONNECTIONS MADE INSIDE (E)
SWITCHGEAR AT OTHER THAN CIRCUIT
BREAKERS OR FUSED SWITCHES LISTED
FOR USE WITH THAT SWITCHGEAR SHALL
BE PERFORMED FOLLOWING
MANUFACTURERS INSTRUCTIONS OR BE
RE-LISTED BY A NRTL. ALL TERMINATIONS
OF ALUMINUM CONDUCTORS SHALL BE
WITH HIGH PRESS CRIMP LUGS ONLY.
WARNING LABEL DETAIL 1/E800
2. (E) UTILITY TENANT LOAD METER. UTILITY
REFERENCE METER NUMBER:
222013-124043
3. (N) PV SYSTEM UTILITY AC DISCONNECT
'ACDS-1'. WARNING LABEL DETAIL 1/E810
4. (N) UTILITY BIDIRECTIONAL KWH METER.
WARNING LABEL DETAIL 1/E810
5. (N) PV SYSTEM MAINTENANCE AC
DISCONNECT 'ACDS-2'. WARNING LABEL
DETAIL 2/E800 & 1/E810
6. NOT USED
7. (N) GRID-INTERACTIVE PV INVERTER
LISTED TO UL 1741 WITH GROUND FAULT
DETECTION & INTERRUPTION. WARNING
LABEL DETAIL 15/E800.
8. NOT USED
9. NOT USED
10. FOR SUPPLY SIDE CONNECTIONS, A
PLAQUE SHALL BE INSTALLED AT THE
MAIN SERVICE DISCONNECTING DEVICE
AND THE PV SYSTEM UTILITY AC
DISCONNECT INDICATING THE LOCATION
OF THE RESPECTIVE SERVICE
DISCONNECT. WARNING LABEL DETAIL
1/E800 & 1/E810
11. NOT USED
12. CONDUCTORS RUN IN PARALLEL SHALL
BE INSTALLED PER ART 310.4/310.10(G)
AND 250.122 (F).
13. NOT USED
14. NEW PULL/JUNCTION BOXES. PROVIDE
SERVICE LOOP IN ALL DC BRANCH
CONDUCTORS SOURCED FROM
ROOFTOPS, MIN LOOP RADIUS = 12X
CONDUCTOR DIAMETER.
15. NOT USED
16. (N) INVERTER INTERNAL DC DISCONNECT
SWITCH(ES). WARNING LABEL DETAIL
3/E800
17. NOT USED
18. (N) PV MODULE LISTED TO UL 1703.
19. EXTRA MODULES THAT ARE UNABLE TO
BE PAIRED WILL HAVE THEIR OWN
OPTIMIZER.
20. (N) COMMUNICATION WIRING TO FOLLOW
MANUFACTURING SPECIFICATIONS.
21. DURING UTILITY GRID OUTAGE THE PV
GENERATION AND BESS WILL
DISCONNECT FROM THE GRID AND
REMAIN DISCONNECTED UNTIL GRID
VOLTAGE IS RESTORED TO THE
ACCEPTED MEASURE.
22. BATTERY AC OUTPUT POWER IS LIMITED
TO THE CORRESPONDING INVERTER OR
TOTAL BATTERIES CONNECTED TO A
SINGLE INVERTER,WHICHEVER IS LOWER.
23. BATTERIES SHOULD NOT BE INSTALLED IN
DIRECT SUNLIGHT OR LOCATIONS
SUBJECTED TO WATER SPRAY.
SPRINKLERS SHOULD BE DIVERTED
WHEN NECESSARY.
24. BATTERIES CAN COMMUNICATE
WIRELESSLY OR VIA RS-485 TO INVERTER.
BATTERIES WITHIN 150' (IDEALLY 50') OF
RESPECTIVE INVERTER CAN USE
WIRELESS COMMUNICATIONS VIA SEDG
HOME NETWORK CARD.
25. COMBINED PV AND BESS OUTPUT POWER
IS LIMITED TO THE INVERTER AC RATING.
26. NOT USED
#
CAT5E 600V RATED SHIELDED CABLE.
INSTALLER SHALL FOLLOW
MANUFACTURES RECOMMENDATION FOR
WIRE SIZING BASED ON LENGTH.
EQUIPMENT TYPE
SYSTEM IDENTIFIER X INDICATES LETTERS
# INDICATES NUMBERS
XX-#.#
1235 E WILSHIRE AVE BLDG 1425 SOMAH10
POI-10 DC STRING SCHEDULE
STR-A STR-B STR-C
TAG DESTINATION CIRCUIT
LENGTH ²
VD% MODULE
WATTAGE
MODULE QTY OPTIMIZER MIN/MAX
MODULES
CIRCUIT
LENGTH ²
VD% MODULE
WATTAGE
MODULE QTY OPTIMIZER MIN/MAX
MODULES
CIRCUIT
LENGTH ²
VD% MODULE
WATTAGE
MODULE QTY OPTIMIZER MIN/MAX
MODULES
DC-10.1.1 INV-10.1 110 0.65%410 14 U650 8 / 16¹110 0.62%410 14 U650 8 / 16¹100 0.59%410 14 U650 8 / 16¹
DC-10.2.2 INV-10.2 90 0.31%410 8 U650 8 / 16¹70 0.22%410 8 U650 8 / 16¹50 0.21%410 10 U650 8 / 16¹
¹ MAXIMUM STRING LENGTH IS USING MANUFACTURES EXCEPTION
² LENGTHS ARE ESTIMATED FOR CALCULATIONS, CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS AND TAKEOFFS
³ WHERE EXPOSED TO PHYSICAL DAMAGE #6 TO BE USED PER NEC 250.120(C)
⁴ AFC VALUES ARE CALCULATED BASED ON WIRE LENGTHS. LENGTHS SHOULD REMAIN GREATER THAN OR EQUAL TO THE LENGTH LISTED IN THE TABLE.
POI-10 DC WIRE SCHEDULE
TAG WIRE GAUGE CONDUCTOR JACKET CCC PER CONDUIT GROUNDING ³EMT RMC PVC 40 PVC 80
DC-10.1.1 CU #8 THWN2 6 CU #10 1"1"1"1 1/4"
DC-10.2.2 CU #8 THWN2 6 CU #10 1"1"1"1 1/4"
POI-10 AC WIRE SCHEDULE
LABEL DESTINATION NOMINAL VAC LINE
SELECTION
FLA FLAX1.25 PHASE
CONDUCTOR
NEUTRAL
CONDUCTOR
GROUNDING
CONDUCTOR
CONDUCTORS
PER PHASE
CONDUIT QTY CIRCUIT
LENGTH ²
SEGMENT
VD%
DC/AC RATIO AFC START AFC END ⁴EMT IMC PVC 40 PVC 80
INV-10.1 LC-10.1 240 A-B 47.5 59.4 CU #6 CU #10 CU #10 1 1 5 0.09% 151.1%6,463 5,817 3/4"3/4"3/4"3/4"
INV-10.2 LC-10.1 240 A-B 31.7 39.6 CU #8 CU #10 CU #10 1 1 5 0.10% 140.3% 6,463 5,510 1/2"1/2"3/4"3/4"
LC-10.1 AC-10.1 240 A-B 79.2 99.0 CU #3 CU #8 CU #8 1 1 70 1.11%--30,734 6,463 1"1"1"1"
AC-10.2 AC-10.1 240 0.0 0.0 CU #14 CU #14 CU #10 1 1 5 0.00%--30,734 7,161 1/2"1/2"1/2"1/2"
AC-10.1 POI-10.10 240 A-B 79.2 99.0 CU #3 CU #3 CU #8 1 1 5 0.08%--42,000 30,734 1"1"1"1 1/4"
M
M
M
M
M FACILITY
LOADS
(N) TENANT
METERS (TYP.)
UTILITY METER REFERENCE NUMBER:
222013-124043
SCE UTILITY GRID 240V,
1ø,3W
11101
-
A
100A
15
(N) POLARIS
BLOCK
POLARIS SUPPLY SIDE TAP
POINT OF INTERCONNECTION
C:\USERS\EMILIANO.MORALES\DESKTOP\WORKING PROJECTS\1235_WILSHIRE_MINNIE\CD100\WILSHIRE MINNIE_WORKINGDOCS_V0\WILSHIRE MINNIE.DWG
POI-8 ONE LINE
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
PROJECT DETAILS:
PV SYSTEM:
·355.88 kW DC
·250.8 kW AC
·331.612 CEC AC
ENERGY STORAGE:
·243.2 kW AC
·756.6 kWH
E609
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER: FINS_TM
ORIGINAL
CONTRACT NUMBER:
3003197607
PJT #: PROP-001235
##KEYED NOTES#EQUIPMENT NOTES#
A INTERCONNECTION LOCATION
NTS
COMMUNICATION
CIRCUIT IDENTIFIER
##KEYED NOTES#EQUIPMENT NOTES#
A INTERCONNECTION LOCATION
NTS
COMMUNICATION
CIRCUIT IDENTIFIER
SYSTEM SUMMARY
19.00 ACKW | 26.24 DCKW | 24.45 CECKW
19.00 BESS ACKW | 58.20 BESS KWH
TOTAL FAULT CURRENTS
UTILITY: 42,000A | GENERATORS: 156.2A
+ -18
14
1 13
14
ES-1
(3
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
1
1
.
1
.
A
-
(
1
3
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
3
)
U
6
5
0
O
P
T
S
.
ST
R
-
1
1
.
1
.
B
-
(
1
3
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
3
)
U
6
5
0
O
P
T
S
.
ST
R
-
1
1
.
1
.
C
-
(
1
2
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
2
)
U
6
5
0
O
P
T
S
.
ES-2
DC-11.1.1
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4A
A-B
60A
INV-11.1
+ -18
14
1 13
14
ES-1
(3
)
S
O
L
A
R
E
D
G
E
B
A
T
-
1
0
K
1
P
B
A
T
T
E
R
I
E
(
S
)
ST
R
-
1
1
.
2
.
A
-
(
8
)
4
1
0
W
M
O
D
U
L
E
W
/
(
8
)
U
6
5
0
O
P
T
S
.
ST
R
-
1
1
.
2
.
B
-
(
8
)
4
1
0
W
M
O
D
U
L
E
W
/
(
8
)
U
6
5
0
O
P
T
S
.
ST
R
-
1
1
.
2
.
C
-
(
1
0
)
4
1
0
W
M
O
D
U
L
E
W
/
(
1
0
)
U
6
5
0
O
P
T
S
.
ES-2
DC-11.2.2
SO
L
A
R
3
16 BA
T
T
E
R
Y
7
12
4B
A-B
40A
INV-11.2
6
LC-11.1
6
8
5 (N) ACDS-2 SYSTEM AC DISCONNECT
SWITCH,, SQUARE D, VHU363RB, 600V RATED,
240V OPERATIONAL, 100A, 3 POLE,
NON-FUSIBLE, NEMA 3R. SEE REFERENCE
SHEETS FOR KAIC RATING.
AC-11.2
M9
4
(N) SCE PV PRODUCTION METER SOCKET
ADDRESS: 1235 E WILSHIRE AVE BLDG 1429
SOMAH11, COOPER B-LINE, 114TB, 100 A,
SERVICE 1 PHASE 3 WIRE 120/240 VAC, NEMA
3R
AC-11.2
10
3
(N) ACDS-1 SYSTEM UTILITY AC DISCONNECT
SWITCH, SQUARE D, VH223NRB, 240V RATED,
240V OPERATIONAL, 100A, 2 POLE, FUSIBLE,
NEMA 3R, OR EQUIVALENT ON THE UTILITIES
APPROVED LIST. CLASS R FUSE WITH
REJECTION CLIPS OR CLASS J FOR 200KAIC
RATING.
A-B
100AAC-11.1
1. PV MODULES (64) QCELLS NORTH
AMERICA Q.PEAK DUO BLK ML-G10.C+ 410
2. (64) SOLAREDGE DC OPTIMIZER U650
3. DC PV AND ESS CONNECTION UNIT W/
INTEGRAL LOAD BREAK DISCONNECT
4. 4A: (1) SOLAREDGE SE11400H-US HOME
HUB [SI1-SB], 11,400W, 240VAC, 1ø, 3W
4B: (1) SOLAREDGE SE7600H-US HOME
HUB [SI1-SB], 7,600W, 240VAC, 1ø, 3W
5. (N) REVENUE GRADE METER, 1ø,
INTERGRATED RGM, W/ NOT REQUIRED
CTS
6. (1) LOAD CENTER, 100A, 1ø, MIN.240VAC,
MIN. 22KAIC, NEMA 3R
7. NOT USED
8. (N) ACDS-2 SYSTEM AC DISCONNECT
SWITCH, SQUARE D, VHU363RB, 600V
RATED, 240V OPERATIONAL, 100A, 3 POLE,
NON-FUSIBLE, NEMA 3R. SEE REFERENCE
SHEETS FOR KAIC RATING.
9. (N) SCE PV PRODUCTION METER SOCKET
ADDRESS: 1235 E WILSHIRE AVE BLDG
1429 SOMAH11, COOPER B-LINE, 114TB,
100A, SERVICE: 1 PHASE 3 WIRE 120/240
VAC, # JAW, NEMA 3R, EUSERC: 304
10. (N) ACDS-1 SYSTEM UTILITY AC
DISCONNECT SWITCH, SQUARE D,
VH223NRB, 240V RATED, 240V
OPERATIONAL, 100A, 2 POLE, FUSIBLE,
NEMA 3R, OR EQUIVALENT ON THE
UTILITIES APPROVED LIST. CLASS R FUSE
WITH REJECTION CLIPS OR CLASS J FOR
200KAIC RATING.
11. (E) MAIN SERVICE EQUIPMENT: 1 PHASE 3
WIRE 120/240 VAC, 125A
12. MANUFACTURER INTERGRATED CELL
CARD
13. (6) SOLAREDGE BAT-10K1P BATTERIES,
9.70KWH, 5,000DCW, NEMA 3R, MOUNTED
TO WALL OR MANUFACTURER FLOOR
MOUNT KIT
14. NOT USED
15. (N) POLARIS BLOCKS
16. NOT USED
1. (E) MAIN SWITCHGEAR AND (N) POINT OF
AC INTERCONNECTION. ALL
CONNECTIONS MADE INSIDE (E)
SWITCHGEAR AT OTHER THAN CIRCUIT
BREAKERS OR FUSED SWITCHES LISTED
FOR USE WITH THAT SWITCHGEAR SHALL
BE PERFORMED FOLLOWING
MANUFACTURERS INSTRUCTIONS OR BE
RE-LISTED BY A NRTL. ALL TERMINATIONS
OF ALUMINUM CONDUCTORS SHALL BE
WITH HIGH PRESS CRIMP LUGS ONLY.
WARNING LABEL DETAIL 1/E800
2. (E) UTILITY TENANT LOAD METER. UTILITY
REFERENCE METER NUMBER:
222013-124041
3. (N) PV SYSTEM UTILITY AC DISCONNECT
'ACDS-1'. WARNING LABEL DETAIL 1/E810
4. (N) UTILITY BIDIRECTIONAL KWH METER.
WARNING LABEL DETAIL 1/E810
5. (N) PV SYSTEM MAINTENANCE AC
DISCONNECT 'ACDS-2'. WARNING LABEL
DETAIL 2/E800 & 1/E810
6. NOT USED
7. (N) GRID-INTERACTIVE PV INVERTER
LISTED TO UL 1741 WITH GROUND FAULT
DETECTION & INTERRUPTION. WARNING
LABEL DETAIL 15/E800.
8. NOT USED
9. NOT USED
10. FOR SUPPLY SIDE CONNECTIONS, A
PLAQUE SHALL BE INSTALLED AT THE
MAIN SERVICE DISCONNECTING DEVICE
AND THE PV SYSTEM UTILITY AC
DISCONNECT INDICATING THE LOCATION
OF THE RESPECTIVE SERVICE
DISCONNECT. WARNING LABEL DETAIL
1/E800 & 1/E810
11. NOT USED
12. CONDUCTORS RUN IN PARALLEL SHALL
BE INSTALLED PER ART 310.4/310.10(G)
AND 250.122 (F).
13. NOT USED
14. NEW PULL/JUNCTION BOXES. PROVIDE
SERVICE LOOP IN ALL DC BRANCH
CONDUCTORS SOURCED FROM
ROOFTOPS, MIN LOOP RADIUS = 12X
CONDUCTOR DIAMETER.
15. NOT USED
16. (N) INVERTER INTERNAL DC DISCONNECT
SWITCH(ES). WARNING LABEL DETAIL
3/E800
17. NOT USED
18. (N) PV MODULE LISTED TO UL 1703.
19. EXTRA MODULES THAT ARE UNABLE TO
BE PAIRED WILL HAVE THEIR OWN
OPTIMIZER.
20. (N) COMMUNICATION WIRING TO FOLLOW
MANUFACTURING SPECIFICATIONS.
21. DURING UTILITY GRID OUTAGE THE PV
GENERATION AND BESS WILL
DISCONNECT FROM THE GRID AND
REMAIN DISCONNECTED UNTIL GRID
VOLTAGE IS RESTORED TO THE
ACCEPTED MEASURE.
22. BATTERY AC OUTPUT POWER IS LIMITED
TO THE CORRESPONDING INVERTER OR
TOTAL BATTERIES CONNECTED TO A
SINGLE INVERTER,WHICHEVER IS LOWER.
23. BATTERIES SHOULD NOT BE INSTALLED IN
DIRECT SUNLIGHT OR LOCATIONS
SUBJECTED TO WATER SPRAY.
SPRINKLERS SHOULD BE DIVERTED
WHEN NECESSARY.
24. BATTERIES CAN COMMUNICATE
WIRELESSLY OR VIA RS-485 TO INVERTER.
BATTERIES WITHIN 150' (IDEALLY 50') OF
RESPECTIVE INVERTER CAN USE
WIRELESS COMMUNICATIONS VIA SEDG
HOME NETWORK CARD.
25. COMBINED PV AND BESS OUTPUT POWER
IS LIMITED TO THE INVERTER AC RATING.
26. NOT USED
#
CAT5E 600V RATED SHIELDED CABLE.
INSTALLER SHALL FOLLOW
MANUFACTURES RECOMMENDATION FOR
WIRE SIZING BASED ON LENGTH.
EQUIPMENT TYPE
SYSTEM IDENTIFIER X INDICATES LETTERS
# INDICATES NUMBERS
XX-#.#
1235 E WILSHIRE AVE BLDG 1429 SOMAH11
POI-11 DC STRING SCHEDULE
STR-A STR-B STR-C
TAG DESTINATION CIRCUIT
LENGTH ²
VD% MODULE
WATTAGE
MODULE QTY OPTIMIZER MIN/MAX
MODULES
CIRCUIT
LENGTH ²
VD% MODULE
WATTAGE
MODULE QTY OPTIMIZER MIN/MAX
MODULES
CIRCUIT
LENGTH ²
VD% MODULE
WATTAGE
MODULE QTY OPTIMIZER MIN/MAX
MODULES
DC-11.1.1 INV-11.1 115 0.63%410 13 U650 8 / 16¹115 0.60%410 13 U650 8 / 16¹110 0.56%410 12 U650 8 / 16¹
DC-11.2.2 INV-11.2 90 0.31%410 8 U650 8 / 16¹60 0.19%410 8 U650 8 / 16¹35 0.15%410 10 U650 8 / 16¹
¹ MAXIMUM STRING LENGTH IS USING MANUFACTURES EXCEPTION
² LENGTHS ARE ESTIMATED FOR CALCULATIONS, CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS AND TAKEOFFS
³ WHERE EXPOSED TO PHYSICAL DAMAGE #6 TO BE USED PER NEC 250.120(C)
⁴ AFC VALUES ARE CALCULATED BASED ON WIRE LENGTHS. LENGTHS SHOULD REMAIN GREATER THAN OR EQUAL TO THE LENGTH LISTED IN THE TABLE.
POI-11 DC WIRE SCHEDULE
TAG WIRE GAUGE CONDUCTOR JACKET CCC PER CONDUIT GROUNDING ³EMT RMC PVC 40 PVC 80
DC-11.1.1 CU #8 THWN2 6 CU #10 1"1"1"1 1/4"
DC-11.2.2 CU #8 THWN2 6 CU #10 1"1"1"1 1/4"
POI-11 AC WIRE SCHEDULE
LABEL DESTINATION NOMINAL VAC LINE
SELECTION
FLA FLAX1.25 PHASE
CONDUCTOR
NEUTRAL
CONDUCTOR
GROUNDING
CONDUCTOR
CONDUCTORS
PER PHASE
CONDUIT QTY CIRCUIT
LENGTH ²
SEGMENT
VD%
DC/AC RATIO AFC START AFC END ⁴EMT IMC PVC 40 PVC 80
INV-11.1 LC-11.1 240 A-B 47.5 59.4 CU #6 CU #10 CU #10 1 1 5 0.09% 136.7%6,118 5,536 3/4"3/4"3/4"3/4"
INV-11.2 LC-11.1 240 A-B 31.7 39.6 CU #8 CU #10 CU #10 1 1 5 0.10% 140.3%6,118 5,257 1/2"1/2"3/4"3/4"
LC-11.1 AC-11.2 240 A-B 79.2 99.0 CU #3 CU #8 CU #8 1 1 70 1.11%--24,234 6,118 1"1"1"1"
AC-11.2 AC-11.1 240 A-B 79.2 99.0 CU #3 CU #8 CU #8 1 1 5 0.08%--30,734 24,234 1"1"1"1"
AC-11.1 POI-11.11 240 A-B 79.2 99.0 CU #3 CU #3 CU #8 1 1 5 0.08%--42,000 30,734 1"1"1"1 1/4"
M
M
M
M
M FACILITY
LOADS
(N) TENANT
METERS (TYP.)
UTILITY METER REFERENCE NUMBER:
222013-124041
SCE UTILITY GRID 240V,
1ø,3W
11101
-
A
125A
15
(N) POLARIS
BLOCK
POLARIS SUPPLY SIDE TAP
POINT OF INTERCONNECTION
C:\USERS\EMILIANO.MORALES\DESKTOP\WORKING PROJECTS\1235_WILSHIRE_MINNIE\CD100\WILSHIRE MINNIE_WORKINGDOCS_V0\WILSHIRE MINNIE.DWG
POI-8 ONE LINE
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
PROJECT DETAILS:
PV SYSTEM:
·355.88 kW DC
·250.8 kW AC
·331.612 CEC AC
ENERGY STORAGE:
·243.2 kW AC
·756.6 kWH
E610
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER: FINS_TM
ORIGINAL
CONTRACT NUMBER:
3003197607
PJT #: PROP-001235
NOTE:
1.RED BACKGROUND
2.WHITE LETTERING
3.TEXT HEIGHT: 1/8" MIN.
3 1/8"
NOTE:
1. MARKING PER ART 690.54
2. RED BACKGROUND
3. WHITE LETTERING
4. TEXT HEIGHT: 1/8" MIN.
NOTE:
1. RED BACKGROUND
2. WHITE LETTERING
3. TEXT HEIGHT: 1/8" MIN.
1 POINT OF INTERCONNECTION
Scale NTS
7 INVERTER AC CIRCUIT BREAKER
Scale NTS
8 SHOCK HAZARD
Scale NTS
4 PV SYSTEM MAINTENANCE DISCONNECT
Scale NTS
2 PV SYSTEM UTILITY AC DISCONNECT
Scale NTS
5 MAIN SERVICE WITH REMOTE PV SYSTEM DISCONNECT
Scale NTS
16 UTILITY NET GENERATION OUTPUT
Scale NTS
9 INVERTER ID
Scale NTS
STRING INVERTERS
CENTRAL INVERTERS
3 1/8"
6 AC COMBINER PANEL
Scale NTS
3 5/8"
3 1/8"
3 DC DISCONNECT
Scale NTS
NOTE:
1. MARKING PER ART 690.17, 690.53
2. RED BACKGROUND
3. WHITE LETTERING
4. TEXT HEIGHT: 1/8" MIN.
CAUTION
SOLAR ELECTRIC
SYSTEM CONNECTED
CAUTION
POWER TO THIS BUILDING IS
ALSO SUPPLIED FROM THE
FOLLOWING SOURCES WITH
DISCONNECT LOCATED AS
SHOWN
!
DO NOT ADD LOADS
PHOTOVOLTAIC SYSTEM
COMBINER PANEL
WARNING !
LABEL LOCATION:
PHOTOVOLTAIC AC COMBINER (IF
APPLICABLE).
PER CODE(S): CEC 2022: 705.12(B)(3)(2),
NEC 2020: 705.12(B)(3)(2), NEC 2017:
705.12(B)(2)(3)(b), NEC 2014:
705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4)
ELECTRICAL SHOCK HAZARD
WARNING!
LABEL LOCATION:
INVERTER(S), AC DISCONNECT(S), AC
COMBINER PANEL (IF APPLICABLE).
PER CODE(S): CEC 2022: 690.13(B), NEC
2020: 690.13(B), NEC 2017: 690.13(B),
NEC 2014: 690.17(E), NEC 2011:
690.17(4)
TERMINALS ON LINE AND LOAD
SIDES MAY BE ENERGIZED IN
THE OPEN POSITION
MAXIMUM AC OPERATING CURRENT:
NOMINAL OPERATING AC VOLTAGE:
AMPS
VAC
PHOTOVOLTAIC AC DISCONNECT
LABEL LOCATION:
AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION.
PER CODE(S): CEC 2022: 690.54, NEC 2020: 690.54, NEC
2017: 690.54, NEC 2014: 690.54, NEC 2011: 690.54
INVERTER
DC SYSTEM SIZE :
NUMBER OF STRINGS:
MODULES PER STRING:
kW
DC SYSTEM SIZE ____kW
POINT OF INTERCONNECTION
PHOTOVOLTAIC POWER SOURCE
ELECTRICAL SHOCK HAZARD
WARNING!
TERMINALS ON LINE AND LOAD
SIDES MAY BE ENERGIZED IN
THE OPEN POSITION
DC PHOTOVOLTAIC
DISCONNECT
PHOTOVOLTAIC DC DISCONNECT
MAXIMUM POWER POINT VOLTAGE(Vmp):
MAXIMUM POWER POINT CURRENT(Imp):
MAXIMUM SYSTEM VOLTAGE(Voc):
SHORT-CIRCUIT CURRENT(Isc):
V
A
V
A
LABEL LOCATION:
INVERTER(S), DC DISCONNECT(S).
PER CODE(S): CEC 2022: 690.53, NEC 2020: 690.53, NEC 2017: 690.53, NEC
2014: 690.53, NEC 2011: 690.53
15 INVERTER WARNING
Scale NTS
ELECTRICAL SHOCK HAZARD
WARNING!
LABEL LOCATION:
INVERTER(S), AC DISCONNECT(S), AC
COMBINER PANEL (IF APPLICABLE).
PER CODE(S): CEC 2022: 690.13(B), NEC
2020: 690.13(B), NEC 2017: 690.13(B),
NEC 2014: 690.17(E), NEC 2011:
690.17(4)
TERMINALS ON LINE AND LOAD
SIDES MAY BE ENERGIZED IN
THE OPEN POSITION
NOT USED
13 NOT USED
Scale NTS
12 RAPID SHUTDOWN LABEL
Scale NTS
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
SOLAR ELECTRIC
PV PANELS
6"
3.5"TURN RAPID SHUTDOWN
SWITCH TO THE "OFF"
POSITION TO SHUT DOWN
PV SYSTEM AND REDUCE
SHOCK HAZARD IN THE
ARRAY.
LABEL LOCATION:
ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING
MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED.
PER CODE(S): CEC 2022: 690.56(C)(1), NEC 2020: 690.56(C)(1); NEC 2017:
690.56(C)(1)(a)
LABEL LOCATION:
INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL
(IF APPLICABLE).
PER CODE(S): CEC 2022: 690.13(B), NEC 2020: 690.13(B),
NEC 2017: 690.13(B), NEC 2014: 690.17(E), NEC 2011:
690.17(4)
ELECTRICAL SHOCK HAZARD
TERMINALS ON THE LINE AND
LOAD SIDES MAY BE ENERGIZED
IN THE OPEN POSITION
WARNING!!
WARNING!
DO NOT RELOCATE THIS
OVERCURRENT DEVICE
POWER SOURCE OUTPUT CONNECTION
LABEL LOCATION:
ADJACENT TO PV BREAKER (IF APPLICABLE).
PER CODE(S): CEC 2022: 705.12(B)(3)(2), NEC
2020: 705.12(B)(3)(2), NEC 2017:
705.12(B)(2)(3)(b), NEC 2014: 705.12(D)(2)(3)(b),
NEC 2011: 705.12(D)(7)
NOTES AND SPECIFICATIONS:
·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE
110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF
REQUESTED BY THE LOCAL AHJ.
·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
WORDS, COLORS AND SYMBOLS.
·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD
AND SHALL NOT BE HAND WRITTEN.
·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
INVOLVED.
·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS
AND LABELS, UNLESS OTHERWISE SPECIFIED.
·DO NOT COVER EXISTING MANUFACTURER LABELS.
MAXIMUM AC OPERATING CURRENT:
NOMINAL OPERATING AC VOLTAGE:
AMPS
VAC
PHOTOVOLTAIC AC DISCONNECT
LABEL LOCATION:
AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION.
PER CODE(S): CEC 2022: 690.54, NEC 2020: 690.54, NEC
2017: 690.54, NEC 2014: 690.54, NEC 2011: 690.54
ELECTRICAL SHOCK HAZARD
WARNING!
LABEL LOCATION:
INVERTER(S), AC DISCONNECT(S), AC
COMBINER PANEL (IF APPLICABLE).
PER CODE(S): CEC 2022: 690.13(B), NEC
2020: 690.13(B), NEC 2017: 690.13(B),
NEC 2014: 690.17(E), NEC 2011:
690.17(4)
TERMINALS ON LINE AND LOAD
SIDES MAY BE ENERGIZED IN
THE OPEN POSITION
INV-1
LABEL LOCATION:
INVERTER (1)
INV-2
LABEL LOCATION:
INVERTER (2)
[When applicable]
INV-3
LABEL LOCATION:
INVERTER (3)
[When applicable]
INV-4
LABEL LOCATION:
INVERTER (4)
[When applicable]
LABEL LOCATION:
INSTALLED WITHIN 3' OF RAPID SHUT DOWN
SWITCH PER CODE(S): NEC 2020: 690.56(C)(2),
CEC 2022: 690.56(C)(2), IFC 2018: 1204.5.3
RAPID SHUTDOWN SWITCH
FOR SOLAR PV SYSTEM
10 RAPID SHUTDOWN SWITCH
Scale NTS
WARNING!
SOURCES: UTILITY GRID
AND PV SOLAR ELECTRIC
SYSTEM
DUAL POWER SUPPLY
LABEL LOCATION:
UTILITY SERVICE METER AND MAIN
SERVICE PANEL.
PER CODE(S): CEC 2022: 705.12(C), NEC
2020: 705.12(C)
14 NOT USED
Scale NTS
NOT USED
11 NOT USED
Scale NTS
NOT USED
CLASS J FUSE ONLY
WARNING!
LABEL LOCATION:
FUSED AC DISCONNECT(S)
FAST-ACTING, CURRENT-LIMIT
EQUIVALENT REQUIRED TO
PREVENT DAMAGE CAUSED BY
SHORT-CIRCUIT EVENTS.
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
WARNING LABELS
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
E800
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#ESTAMP
WILSHIRE MINNIE
1209 E WILSHIRE AVE UNIT# MTR02
1209 3/4 E WILSHIRE AVE UNIT# ELE01
1221 E WILSHIRE AVE UNIT# MTR02
1221 3/4 E WILSHIRE AVE UNIT# ELE01
1229 E WILSHIRE AVE UNIT# MTR02
1229 3/4 E WILSHIRE AVE UNIT# ELE01
1233 E WILSHIRE AVE UNIT# MTR01
1401 S MINNIE ST UNIT# MTR01
1403 S MINNIE ST UNIT# MTR01
1425 S MINNIE ST UNIT# MTR01
APN: 014-251-49 / 014-251-50
DEVELOPER: C&C DEVELOPMENT
1 ESS AC DISCONNECT
Scale NTS
3 POI-1 ESS ARC FLASH AND SHOCK HAZARD
Scale NTS 4 POI-2 ESS ARC FLASH AND SHOCK HAZARD
Scale NTS
1
0 0
N.A.
2 NFPA 704 SIGNAGE - SEDG ENERGY BANK BESS
Scale NTS
15"
15"
6"
7-1/2"7-1/2"
LABEL LOCATION:
SIGNS SHOULD BE PLACED
WHERE THEY ARE EASILY VISIBLE
IN CASE OF AN EMERGENCY,
SUCH AS ON EXTERIOR WALLS OF
BUILDINGS, ENTRANCES TO
ROOMS OR AREAS, AND
PRINCIPAL ACCESS POINTS TO
EXTERIOR STORAGE AREAS.
LABEL LOCATION:
ON OR NEAR THE ESS DISCONNECTING MEANS I.E
INVERTERS FOR DC-COUPLED ESS
ENERGY STORAGE SYSTEM
AC DISCONNECT
ENERGY STORAGE SYSTEM DISCONNECT
ARC FLASH AND SHOCK HAZARD
WARNING!
APPROPRIATE PPE AND TOOLS REQUIRED WHILE WORKING ON THIS EQUIPMENT
REFER TO NFPA 70 E.
LABEL LOCATION:
ESS AC DISCONNECT(S), AC
COMBINER PANEL (IF APPLICABLE).
PER CODE(S): NEC 2020 706.15(C)(4)
2 7/8"
4 1/8"
NOMINAL ESS AC VOLTAGE:
MAXIMUM ESS DC VOLTAGE:
AVAILABLE FAULT CURRENT
DERIVED FROM THE ESS:
DATE CALCULATION PREFORMED:
240 VAC
450 VDC
222A
2/18/26
ENERGY STORAGE SYSTEM DISCONNECT
ARC FLASH AND SHOCK HAZARD
WARNING!
APPROPRIATE PPE AND TOOLS REQUIRED WHILE WORKING ON THIS EQUIPMENT
REFER TO NFPA 70 E.
LABEL LOCATION:
ESS AC DISCONNECT(S), AC
COMBINER PANEL (IF APPLICABLE).
PER CODE(S): NEC 2020 706.15(C)(4)
2 7/8"
4 1/8"
NOMINAL ESS AC VOLTAGE:
MAXIMUM ESS DC VOLTAGE:
AVAILABLE FAULT CURRENT
DERIVED FROM THE ESS:
DATE CALCULATION PREFORMED:
240 VAC
450 VDC
296 A
2/18/26
5 POI-3 ESS ARC FLASH AND SHOCK HAZARD
Scale NTS 6 POI-4 ESS ARC FLASH AND SHOCK HAZARD
Scale NTS
ENERGY STORAGE SYSTEM DISCONNECT
ARC FLASH AND SHOCK HAZARD
WARNING!
APPROPRIATE PPE AND TOOLS REQUIRED WHILE WORKING ON THIS EQUIPMENT
REFER TO NFPA 70 E.
LABEL LOCATION:
ESS AC DISCONNECT(S), AC
COMBINER PANEL (IF APPLICABLE).
PER CODE(S): NEC 2020 706.15(C)(4)
2 7/8"
4 1/8"
NOMINAL ESS AC VOLTAGE:
MAXIMUM ESS DC VOLTAGE:
AVAILABLE FAULT CURRENT
DERIVED FROM THE ESS:
DATE CALCULATION PREFORMED:
240 VAC
450 VDC
222 A
2/18/26
7 POI-5 ESS ARC FLASH AND SHOCK HAZARD
Scale NTS 8 POI-6 ESS ARC FLASH AND SHOCK HAZARD
Scale NTS
ENERGY STORAGE SYSTEM DISCONNECT
ARC FLASH AND SHOCK HAZARD
WARNING!
APPROPRIATE PPE AND TOOLS REQUIRED WHILE WORKING ON THIS EQUIPMENT
REFER TO NFPA 70 E.
LABEL LOCATION:
ESS AC DISCONNECT(S), AC
COMBINER PANEL (IF APPLICABLE).
PER CODE(S): NEC 2020 706.15(C)(4)
2 7/8"
4 1/8"
NOMINAL ESS AC VOLTAGE:
MAXIMUM ESS DC VOLTAGE:
AVAILABLE FAULT CURRENT
DERIVED FROM THE ESS:
DATE CALCULATION PREFORMED:
240 VAC
450 VDC
222 A
2/18/26
9 POI-7 ESS ARC FLASH AND SHOCK HAZARD
Scale NTS
ENERGY STORAGE SYSTEM DISCONNECT
ARC FLASH AND SHOCK HAZARD
WARNING!
APPROPRIATE PPE AND TOOLS REQUIRED WHILE WORKING ON THIS EQUIPMENT
REFER TO NFPA 70 E.
LABEL LOCATION:
ESS AC DISCONNECT(S), AC
COMBINER PANEL (IF APPLICABLE).
PER CODE(S): NEC 2020 706.15(C)(4)
2 7/8"
4 1/8"
NOMINAL ESS AC VOLTAGE:
MAXIMUM ESS DC VOLTAGE:
AVAILABLE FAULT CURRENT
DERIVED FROM THE ESS:
DATE CALCULATION PREFORMED:
240 VAC
450 VDC
148 A
2/18/26
ENERGY STORAGE SYSTEM DISCONNECT
ARC FLASH AND SHOCK HAZARD
WARNING!
APPROPRIATE PPE AND TOOLS REQUIRED WHILE WORKING ON THIS EQUIPMENT
REFER TO NFPA 70 E.
LABEL LOCATION:
ESS AC DISCONNECT(S), AC
COMBINER PANEL (IF APPLICABLE).
PER CODE(S): NEC 2020 706.15(C)(4)
2 7/8"
4 1/8"
NOMINAL ESS AC VOLTAGE:
MAXIMUM ESS DC VOLTAGE:
AVAILABLE FAULT CURRENT
DERIVED FROM THE ESS:
DATE CALCULATION PREFORMED:
240 VAC
450 VDC
148 A
2/18/26
ENERGY STORAGE SYSTEM DISCONNECT
ARC FLASH AND SHOCK HAZARD
WARNING!
APPROPRIATE PPE AND TOOLS REQUIRED WHILE WORKING ON THIS EQUIPMENT
REFER TO NFPA 70 E.
LABEL LOCATION:
ESS AC DISCONNECT(S), AC
COMBINER PANEL (IF APPLICABLE).
PER CODE(S): NEC 2020 706.15(C)(4)
2 7/8"
4 1/8"
NOMINAL ESS AC VOLTAGE:
MAXIMUM ESS DC VOLTAGE:
AVAILABLE FAULT CURRENT
DERIVED FROM THE ESS:
DATE CALCULATION PREFORMED:
240 VAC
450 VDC
148 A
2/18/26
BATTERY ID
CONNECTED INV LABEL :
INV SERIAL NO.:
BATTERY SERIAL NO.:
LABEL LOCATION:
All Batteries[When applicable].
Use Connected Inv Label names as 1.1, 1.2,..for POI#1, 2.1, 2.2,...for POI#2
and so on.
Last 4 digits of the serial numbers can be used.
INV-
LABEL LOCATION:
ALL INVERTERS
Match Inv labels as shown in
Plans. Ex. 1.1, 1.2, 1.3,
2.1,2.2, 3.1, 3.2 and so on
10 BATTERY MAPPING SIGNAGES
Scale NTS
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
WARNING LABELS
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
E801
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
#ESTAMP
WILSHIRE MINNIE
1209 E WILSHIRE AVE UNIT# MTR02
1209 3/4 E WILSHIRE AVE UNIT# ELE01
1221 E WILSHIRE AVE UNIT# MTR02
1221 3/4 E WILSHIRE AVE UNIT# ELE01
1229 E WILSHIRE AVE UNIT# MTR02
1229 3/4 E WILSHIRE AVE UNIT# ELE01
1233 E WILSHIRE AVE UNIT# MTR01
1401 S MINNIE ST UNIT# MTR01
1403 S MINNIE ST UNIT# MTR01
1425 S MINNIE ST UNIT# MTR01
APN: 014-251-49 / 014-251-50
DEVELOPER: C&C DEVELOPMENT
NGOM
M
SCE LINE SIDE
DISCONNECT
GENERATION LOAD
SIDE DISCONNECTUTILITY
DISTRIBUTION
SYSTEM
1
3
8
2
7
9
PV
GENERATION
FACILITY
46
5
SCE LINE SIDE DISCONNECT
LABEL LOCATION:
LINE SIDE DISCONNECT
LABEL LOCATION:
LOAD SIDE DISCONNECT
LABEL LOCATION:
IF PANEL MODIFICATIONS ARE MADE
APPROPRIATE PLACARDS MUST BE INSTALLED
LABELING THE SECTIONS.
1
2
7
LABEL LOCATION:
THE WIRING SEQUENCE OF
FACTORY-INSTALLED TEST-BYPASS BLOCKS,
FROM LEFT TO RIGHT, IS LINE-LOAD,
LINE-LOAD, LINE-LOAD. THIS WIRING
SEQUENCE SHALL BE PERMANENTLY
LABELED IN 3/4-INCH BLOCK LETTERS BELOW
THE TEST-BYPASS TERMINALS. LINE AND
LOAD CONDUCTORS SHALL BE CONNECTED
ONLY TO TEST-BYPASS BLOCK TERMINALS
DESIGNED AS LINE AND LOAD,
RESPECTIVELY.
3
LABEL LOCATION:
ON THE METER PANEL OR ADJACENT TO THE
METER SOCKET. ACCEPTABLE METHODS FOR
LABELING CUSTOMER NGO METERING
SECTIONS OR PANEL(S) SHALL BE EITHER BY
PERMANENTLY ATTACHED
MACHINE-ENGRAVED LAMINATED PHENOLIC
(OR EQUAL) TAGS OR BY PERMANENT
STENCILED PAINT LETTERING. TEXT HEIGHT
MIN. 1/4".
8
SCE METERING PLACARDS
NTS
SOLAR INTERCONNECTION
TERMINATION SECTION
LINE LOAD
SCE UTILITY TERMINATION
SECTION
DISCONNECT 1 OF 2
GENERATION LOAD SIDE
DISCONNECT
DISCONNECT 2 OF 2
NET GENERATION OUTPUT
METERING
NOTE: SCE REQUIRES A SAFETY-SOCKET BOX WITH FACTORY-INSTALLED
TEST-BYPASS BLOCKS FOR NON-INSTRUMENT RATED (SELF-CONTAINED)
NGO METERING. FOR SWITCHBOARDS/SWITCHGEAR, THE CUSTOMER MUST
LABEL THE GENERATOR OUTPUT BUS/CABLE DIRECTION (E.G., "TOP
GENERATOR FED"). IF NGO AND PCC METERING ARE SEPARATED BY OVER
100 FEET OR ON DIFFERENT LEVELS, A PERMANENT SIGN AT THE PCC METER
MUST INDICATE THE NGO METER'S LOCATION.
CURRENT FLOW
LABEL LOCATION:
FOR INSTRUMENT TRANSFORMER RATED CT
NGOM PANELS, THE ARROW POINTING
TOWARDS THE UTILITY SIDE DISCONNECT
SHALL BE INSTALLED ON THE INSIDE SIDE
WALL OF PANEL OR ON THE OUTSIDE FRONT
OF NGOM PANEL.
5
SCE LINE SIDE PV LOAD SIDE
LABEL LOCATION:
PULL SECTIONS
4
GRID GENERATION
LABEL LOCATION:
GRID AND GENERATION CONDUCTORS
6
LABEL LOCATION:
PLACE A UNIQUE ADDRESS PLACARD ON THE
NGOM THAT MATCHES THE AHJ PERMIT AND
THE SCE SERVICE REQUEST ADDRESS.
9
123 MAIN ST. SOMAH1
NOTE: IF INTERCONNECTION IS MADE WITHIN A NEW TERMINATION
CAN, THE "SOLAR INTERCONNECTION TERMINATION SECTION"
PLACARD IS REQUIRED
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
SITE PLACARDS
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
E810
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
#ESTAMP
MULTIPLE SOURCES OF POWER
CAUTION:
1209 E WILSHIRE AVE UNIT# MTR02
PV ARRAY
DIRECTORY
PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF
THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC
SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION
[NEC 690.56(B)]
WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, A
DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE INSTALLED AT EACH DC PV
SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND
AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF
ALL AC AND DC PV SYSTEM DISCONNECTING MEANS IN THE BUILDING.
[NEC 690.4(D)]
CAUTION:
DIRECTORY
PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF
THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC
SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION
[NEC 690.56(B)]
WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, A
DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE INSTALLED AT EACH DC PV
SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND
AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF
ALL AC AND DC PV SYSTEM DISCONNECTING MEANS IN THE BUILDING.
[NEC 690.4(D)]
CAUTION:
DIRECTORY
PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF
THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC
SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION
[NEC 690.56(B)]
WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, A
DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE INSTALLED AT EACH DC PV
SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND
AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF
ALL AC AND DC PV SYSTEM DISCONNECTING MEANS IN THE BUILDING.
[NEC 690.4(D)]
CAUTION:
DIRECTORY
PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF
THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC
SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION
[NEC 690.56(B)]
WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, A
DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE INSTALLED AT EACH DC PV
SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND
AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF
ALL AC AND DC PV SYSTEM DISCONNECTING MEANS IN THE BUILDING.
[NEC 690.4(D)]
CAUTION:
DIRECTORY
PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF
THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC
SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION
[NEC 690.56(B)]
WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, A
DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE INSTALLED AT EACH DC PV
SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND
AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF
ALL AC AND DC PV SYSTEM DISCONNECTING MEANS IN THE BUILDING.
[NEC 690.4(D)]
CAUTION:
DIRECTORY
PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF
THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC
SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION
[NEC 690.56(B)]
WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, A
DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE INSTALLED AT EACH DC PV
SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND
AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF
ALL AC AND DC PV SYSTEM DISCONNECTING MEANS IN THE BUILDING.
[NEC 690.4(D)]
PV ARRAY
PV ARRAY
* YOU ARE HERE *
MAIN SERVICE DISCONNECT
POI LOCATION (EXT.)
AC DISCONNECT(FUSED)(EXT.)
NGOM METER (EXT.)
AC DISCONNECT(NON-FUSED)(EXT.)
BESS
LOCATION
(EXT.)
1213 E
WILSHIRE
AVE
1401
MINNIE ST
PV
INVERTERS
LOCATION
(EXT.)
POI-4POI-3POI-2POI-1
POI-6POI-5
1221 E WILSHIRE AVE UNIT# MTR02 1229 E WILSHIRE AVE UNIT# MTR02 1233 E WILSHIRE AVE UNIT# MTR01
1401 S MINNIE ST UNIT# MTR01 1403 S MINNIE ST UNIT# MTR01
CAUTION:
DIRECTORY
PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF
THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC
SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION
[NEC 690.56(B)]
WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, A
DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE INSTALLED AT EACH DC PV
SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND
AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF
ALL AC AND DC PV SYSTEM DISCONNECTING MEANS IN THE BUILDING.
[NEC 690.4(D)]
POI-7
1425 S MINNIE ST UNIT# MTR01
MULTIPLE SOURCES OF POWER MULTIPLE SOURCES OF POWER MULTIPLE SOURCES OF POWER
MULTIPLE SOURCES OF POWER MULTIPLE SOURCES OF POWER MULTIPLE SOURCES OF POWER
E WILSHIRE AVE
1209 E
WILSHIRE
AVE
1201 E
WILSHIRE
AVE
PV ARRAY PV ARRAY
E WILSHIRE AVE
1225 E
WILSHIRE
AVE
1221 E
WILSHIRE
AVE
PV ARRAY
PV ARRAY
BESS
LOCATION
(EXT.)
PV
INVERTERS
LOCATION
(EXT.)
* YOU ARE HERE *
MAIN SERVICE DISCONNECT
POI LOCATION (EXT.)AC DISCONNECT(FUSED)(EXT.)
NGOM METER (EXT.)
AC DISCONNECT(NON-FUSED)(EXT.)
E WILSHIRE AVE
BESS
LOCATION
(EXT.)
PV
INVERTERS
LOCATION
(EXT.)
1229 E
WILSHIRE
AVE
PV ARRAY
1235 E
WILSHIRE
AVE
* YOU ARE HERE *
MAIN SERVICE DISCONNECT
POI LOCATION (EXT.)
AC DISCONNECT(NON-FUSED)(EXT.)NGOM METER (EXT.)
AC DISCONNECT(FUSED)(EXT.)
E WILSHIRE AVE
1233 E
WILSHIRE
AVE
BESS
LOCATION
(EXT.)
PV
INVERTERS
LOCATION
(EXT.)
* YOU ARE HERE *
MAIN SERVICE DISCONNECT
POI LOCATION (EXT.)
AC DISCONNECT(NON-FUSED)(EXT.)
NGOM METER (EXT.)
AC DISCONNECT(FUSED)(EXT.)
MINNIE ST
BESS
LOCATION
(EXT.)
* YOU ARE HERE *
MAIN SERVICE DISCONNECT
POI LOCATION (EXT.)
PV
INVERTERS
LOCATION
(EXT.)
AC DISCONNECT(FUSED)(EXT.)
NGOM METER (EXT.)
AC DISCONNECT(NON-FUSED)(EXT.)
MINNIE ST MINNIE ST
PV ARRAY
1403
MINNIE ST
BESS
LOCATION
(EXT.)
PV
INVERTERS
LOCATION
(EXT.)
* YOU ARE HERE *
MAIN SERVICE DISCONNECT
POI LOCATION (EXT.)AC DISCONNECT(FUSED)(EXT.)
NGOM METER (EXT.)
AC DISCONNECT(NON-FUSED)(EXT.)
PV ARRAY
1425
MINNIE ST
BESS
LOCATION
(EXT.)
PV
INVERTERS
LOCATION
(EXT.)
* YOU ARE HERE *
MAIN SERVICE DISCONNECT
POI LOCATION (EXT.)AC DISCONNECT(FUSED)(EXT.)
NGOM METER (EXT.)
AC DISCONNECT(NON-FUSED)(EXT.)
WILSHIRE MINNIE
1209 E WILSHIRE AVE UNIT# MTR02
1209 3/4 E WILSHIRE AVE UNIT# ELE01
1221 E WILSHIRE AVE UNIT# MTR02
1221 3/4 E WILSHIRE AVE UNIT# ELE01
1229 E WILSHIRE AVE UNIT# MTR02
1229 3/4 E WILSHIRE AVE UNIT# ELE01
1233 E WILSHIRE AVE UNIT# MTR01
1401 S MINNIE ST UNIT# MTR01
1403 S MINNIE ST UNIT# MTR01
1425 S MINNIE ST UNIT# MTR01
APN: 014-251-49 / 014-251-50
DEVELOPER: C&C DEVELOPMENT
1235 E WILSHIRE AVE BLDG 1421 SOMAH9
DIRECTORY
PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF
THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC
SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION
[NEC 690.56(B)]
WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, A
DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE INSTALLED AT EACH DC PV
SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND
AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF
ALL AC AND DC PV SYSTEM DISCONNECTING MEANS IN THE BUILDING.
[NEC 690.4(D)]
POI-9
POWER TO THIS BUILDING IS ALSO
SUPPLIED FROM THE FOLLOWING
SOURCES WITH DISCONNECTS AS
SHOWN
CAUTION:
1235 E WILSHIRE AVE BLDG 1425 SOMAH10
DIRECTORY
PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF
THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC
SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION
[NEC 690.56(B)]
WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, A
DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE INSTALLED AT EACH DC PV
SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND
AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF
ALL AC AND DC PV SYSTEM DISCONNECTING MEANS IN THE BUILDING.
[NEC 690.4(D)]
POI-10
POWER TO THIS BUILDING IS ALSO
SUPPLIED FROM THE FOLLOWING
SOURCES WITH DISCONNECTS AS
SHOWN
CAUTION:
1235 E WILSHIRE AVE BLDG 1429 SOMAH11
DIRECTORY
PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF
THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC
SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION
[NEC 690.56(B)]
WHERE THE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, A
DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE INSTALLED AT EACH DC PV
SYSTEM DISCONNECTING MEANS, AT EACH AC DISCONNECTING MEANS, AND
AT THE MAIN SERVICE DISCONNECTING MEANS SHOWING THE LOCATION OF
ALL AC AND DC PV SYSTEM DISCONNECTING MEANS IN THE BUILDING.
[NEC 690.4(D)]
POI-11
PV ARRAY
PV ARRAY
POI LOCATION (EXT.)
POI LOCATION (EXT.)
TENANT METERS (EXT.)
AC DISCONNECT(FUSED)(EXT.)
NGOM METER (EXT.)
AC DISCONNECT(NON-FUSED)(EXT.)
BESS LOCATION (EXT.)
TENANT METERS (EXT.)AC DISCONNECT(FUSED)(EXT.)
NGOM METER (EXT.)
AC DISCONNECT(NON-FUSED)(EXT.)
BESS LOCATION (EXT.)
BLDG 1421
BLDG 1429
PV INVERTER AND
ESS AC DISCONNECT
LOCATION (EXT.)
PV INVERTER AND
ESS AC DISCONNECT
LOCATION (EXT.)
C:\USERS\EMILIANO.MORALES\DESKTOP\WORKING PROJECTS\1235_WILSHIRE_MINNIE\CD100\WILSHIRE MINNIE_WORKINGDOCS_V0\WILSHIRE MINNIE.DWG
SITE PLACARDS
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
PROJECT DETAILS:
PV SYSTEM:
·355.88 kW DC
·250.8 kW AC
·331.612 CEC AC
ENERGY STORAGE:
·243.2 kW AC
·756.6 kWH
E811
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER: FINS_TM
ORIGINAL
CONTRACT NUMBER:
3003197607
PJT #: PROP-001235
C:\USERS\EMILIANO.MORALES\DESKTOP\WORKING PROJECTS\1235_WILSHIRE_MINNIE\CD100\WILSHIRE MINNIE_WORKINGDOCS_V0\WILSHIRE MINNIE.DWG
POWER TO THIS BUILDING IS ALSO
SUPPLIED FROM THE FOLLOWING
SOURCES WITH DISCONNECTS AS
SHOWN
CAUTION:
PV ARRAY
POI LOCATION (EXT.)
TENANT METERS (EXT.)
AC DISCONNECT(FUSED)(EXT.)
NGOM METER (EXT.)
AC DISCONNECT(NON-FUSED)(EXT.)
BESS LOCATION (EXT.)
BLDG 1425
PV INVERTER AND
ESS AC DISCONNECT
LOCATION (EXT.)
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
REFERENCE SHEET - 1
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
R100
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
WILSHIRE MINNIE
1209 E WILSHIRE AVE UNIT# MTR02
1209 3/4 E WILSHIRE AVE UNIT# ELE01
1221 E WILSHIRE AVE UNIT# MTR02
1221 3/4 E WILSHIRE AVE UNIT# ELE01
1229 E WILSHIRE AVE UNIT# MTR02
1229 3/4 E WILSHIRE AVE UNIT# ELE01
1233 E WILSHIRE AVE UNIT# MTR01
1401 S MINNIE ST UNIT# MTR01
1403 S MINNIE ST UNIT# MTR01
1425 S MINNIE ST UNIT# MTR01
APN: 014-251-49 / 014-251-50
DEVELOPER: C&C DEVELOPMENT
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
REFERENCE SHEET - 2
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
R101
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
WILSHIRE MINNIE
1209 E WILSHIRE AVE UNIT# MTR02
1209 3/4 E WILSHIRE AVE UNIT# ELE01
1221 E WILSHIRE AVE UNIT# MTR02
1221 3/4 E WILSHIRE AVE UNIT# ELE01
1229 E WILSHIRE AVE UNIT# MTR02
1229 3/4 E WILSHIRE AVE UNIT# ELE01
1233 E WILSHIRE AVE UNIT# MTR01
1401 S MINNIE ST UNIT# MTR01
1403 S MINNIE ST UNIT# MTR01
1425 S MINNIE ST UNIT# MTR01
APN: 014-251-49 / 014-251-50
DEVELOPER: C&C DEVELOPMENT
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
REFERENCE SHEET - 3
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
R102
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
WILSHIRE MINNIE
1209 E WILSHIRE AVE UNIT# MTR02
1209 3/4 E WILSHIRE AVE UNIT# ELE01
1221 E WILSHIRE AVE UNIT# MTR02
1221 3/4 E WILSHIRE AVE UNIT# ELE01
1229 E WILSHIRE AVE UNIT# MTR02
1229 3/4 E WILSHIRE AVE UNIT# ELE01
1233 E WILSHIRE AVE UNIT# MTR01
1401 S MINNIE ST UNIT# MTR01
1403 S MINNIE ST UNIT# MTR01
1425 S MINNIE ST UNIT# MTR01
APN: 014-251-49 / 014-251-50
DEVELOPER: C&C DEVELOPMENT
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
REFERENCE SHEET - 4
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
R103
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
WILSHIRE MINNIE
1209 E WILSHIRE AVE UNIT# MTR02
1209 3/4 E WILSHIRE AVE UNIT# ELE01
1221 E WILSHIRE AVE UNIT# MTR02
1221 3/4 E WILSHIRE AVE UNIT# ELE01
1229 E WILSHIRE AVE UNIT# MTR02
1229 3/4 E WILSHIRE AVE UNIT# ELE01
1233 E WILSHIRE AVE UNIT# MTR01
1401 S MINNIE ST UNIT# MTR01
1403 S MINNIE ST UNIT# MTR01
1425 S MINNIE ST UNIT# MTR01
APN: 014-251-49 / 014-251-50
DEVELOPER: C&C DEVELOPMENT
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
REFERENCE SHEET - 5
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
R104
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
WILSHIRE MINNIE
1209 E WILSHIRE AVE UNIT# MTR02
1209 3/4 E WILSHIRE AVE UNIT# ELE01
1221 E WILSHIRE AVE UNIT# MTR02
1221 3/4 E WILSHIRE AVE UNIT# ELE01
1229 E WILSHIRE AVE UNIT# MTR02
1229 3/4 E WILSHIRE AVE UNIT# ELE01
1233 E WILSHIRE AVE UNIT# MTR01
1401 S MINNIE ST UNIT# MTR01
1403 S MINNIE ST UNIT# MTR01
1425 S MINNIE ST UNIT# MTR01
APN: 014-251-49 / 014-251-50
DEVELOPER: C&C DEVELOPMENT
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
UL9540A
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
R105
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
WILSHIRE MINNIE
1209 E WILSHIRE AVE UNIT# MTR02
1209 3/4 E WILSHIRE AVE UNIT# ELE01
1221 E WILSHIRE AVE UNIT# MTR02
1221 3/4 E WILSHIRE AVE UNIT# ELE01
1229 E WILSHIRE AVE UNIT# MTR02
1229 3/4 E WILSHIRE AVE UNIT# ELE01
1233 E WILSHIRE AVE UNIT# MTR01
1401 S MINNIE ST UNIT# MTR01
1403 S MINNIE ST UNIT# MTR01
1425 S MINNIE ST UNIT# MTR01
APN: 014-251-49 / 014-251-50
DEVELOPER: C&C DEVELOPMENT
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
UL9540A
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
R106
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
WILSHIRE MINNIE
1209 E WILSHIRE AVE UNIT# MTR02
1209 3/4 E WILSHIRE AVE UNIT# ELE01
1221 E WILSHIRE AVE UNIT# MTR02
1221 3/4 E WILSHIRE AVE UNIT# ELE01
1229 E WILSHIRE AVE UNIT# MTR02
1229 3/4 E WILSHIRE AVE UNIT# ELE01
1233 E WILSHIRE AVE UNIT# MTR01
1401 S MINNIE ST UNIT# MTR01
1403 S MINNIE ST UNIT# MTR01
1425 S MINNIE ST UNIT# MTR01
APN: 014-251-49 / 014-251-50
DEVELOPER: C&C DEVELOPMENT
D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG
UL9540A
CONTRACTOR:
ENGINEERING APPROVAL:
600 CALIFORNIA ST #1800, SAN
FRANCISCO, CA 94104
CA CL #750184
UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
WILSHIRE MINNIE
1235 E WILSHIRE AVE,
SANTA ANA, CA 92707, USA
APN:014-251-49/014-251-50
DEVELOPER:
C&C DEVELOPMENT
DESCRIPTION DATE REV
0ORIGINAL06/23/25
BAHJ COMMENTS #2 12/10/25
CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26
PROJECT DETAILS:
PV SYSTEM:
·259.12 kW DC
·186.2 kW AC
·241.45 CEC AC
ENERGY STORAGE:
·184.8 kW AC
·523.8 kWH
R107
SHEET SIZE:
REVISION:
SHEET TITLE:
36" X 24" (ARCH D)
DESIGNER:
FINS_TM
C
PROJECT NUMBER:
PROP-001235
ASYSTEM DOWNSIZED 09/05/25
AHJ COMMENTS #1 &
WILSHIRE MINNIE
1209 E WILSHIRE AVE UNIT# MTR02
1209 3/4 E WILSHIRE AVE UNIT# ELE01
1221 E WILSHIRE AVE UNIT# MTR02
1221 3/4 E WILSHIRE AVE UNIT# ELE01
1229 E WILSHIRE AVE UNIT# MTR02
1229 3/4 E WILSHIRE AVE UNIT# ELE01
1233 E WILSHIRE AVE UNIT# MTR01
1401 S MINNIE ST UNIT# MTR01
1403 S MINNIE ST UNIT# MTR01
1425 S MINNIE ST UNIT# MTR01
APN: 014-251-49 / 014-251-50
DEVELOPER: C&C DEVELOPMENT
YES NO
INSTRUCTIONS:
ORAN GE COUNTY FI RE AUTHORI TY
Plan Submittal Criteria
COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects
and RESIDENTIAL TRACT developments
· Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place.
· Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section.
· If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA.
· In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations.
· Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding
requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602.
Address Suite City
Project Scope/Business Description
1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways,
curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within
300 feet of an active or proposed oil well? Fire Master Plan (PR145)
2. Property is adjacent to a wildland area or non-irrigated native vegetation?
Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124)
3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from
an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170)
4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving
private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475)
5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000
sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable
to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless
classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration
or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses
where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories
with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285)
6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card,
button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan
depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520)
7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment;
industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible
liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium
ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations?
Special Equipment Plan (PR315, PR340-PR382)
8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft
maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if
H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240)
9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard
commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330)
10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a
commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335)
Initial each of the following two items indicating that you have read and understand the statement:
11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is
required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed
Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications.
12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located
in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327—
Initials the building department will determine specific requirements.
I certify under penalty of perjury under the laws of the State of California that the above is true:
Print Name Signature
Phone Number ( ) Date / /
Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA
review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the
applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the
appropriate plans and fees for OCFA review. 10-08-14 EE
COM
O R A N G E C O U N T Y F I R E A U T H O R I T Y
Plan Referral Form
Required for OCFA to review plans upon the request of the Building Department when
the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”.
City / County Official Requesting Review:
City / County Reference #: Date: __________________________________
City / County: _____________________________________ E-Mail: __________________________________
Contact Name: _____________________________________ Phone #: _________________________________
Title: _____________________________________
** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. **
Reason(s) for Review:
Please describe why OCFA Plan Review is or may be required by the City/County :
OCFA COMMENTS:
No further action required on this specific plan type, based
on information provided on: ____/______/______.
Project to be taken in for OCFA Review.
Other:
Name: _________________________________________
Contact #: ______________________________________ Date: _________________________________
OCFA Authorization
Updated: 06/02/2020 rs
STRUCTURAL CALCULATIONS
FOR THE
WILSHIRE MINNIE
ROOFTOP PV
1235 E WILSHIRE AVE.
SANTA ANA, CA 92707
ORANGE COUNTY
CA
Issue Date:
10/24/2025
jeremy@roguestructures.com
Rogue Structures Project #: 21-001
1 of 11
FOR PAGES 1-11
10/24/2510/24/25
WILSHIRE MINNIE
ROOFTOP PV
Project No. 21-001
6/26/25
PROJECT DESCRIPTION:
- Existing buildings are being checked to a support PV system
PROJECT LOCATION:
2 of 11
ASCE Hazards Report
Address:
1235 E Wilshire Ave
Santa Ana, California
92707
Standard:ASCE/SEI 7-16 Latitude:33.73068
Risk Category:II Longitude:-117.855471
Soil Class:D - Default (see
Section 11.4.3)
Elevation:89.14482221615128 ft
(NAVD 88)
Wind
Results:
Wind Speed 95 Vmph
10-year MRI 66 Vmph
25-year MRI 72 Vmph
50-year MRI 76 Vmph
100-year MRI 81 Vmph
Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2
Date Accessed: Wed Jun 25 2025
Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear
interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds
correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability =
0.00143, MRI = 700 years).
Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2.
Page 1 of 3https://ascehazardtool.org/Thu Jun 26 2025
3 of 11
WILSHIRE MINNIE
ROOFTOP PV
Project No. 21-001
6/26/25
ROOFTOP SOLAR PANELS PARALLEL TO THE ROOF SURFACE PER ASCE 7-16 29.4.4
Roof Mounted PV Attachment Calculations
p = q h (GC p )(E )(a )
Kz =0.62 ASCE7 Table 26.10-1
Kzt =1.00
Kd =0.85 ASCE7 Table 26.6-1
V =95 mph
Exposure =B
qz =12.3 psf (Ultimate)
Building Type:
Surface Type: Roof
Roof Angle : 10
Roof Height: 20 ft Height of Canopy
E=1.5
a=0.8
1, 2e 2r, 2n
GC:-2.0 -2.54
-28.7 -37.3 psf (Ultimate)
-17.2 -22.4 psf (Working Stress)
Module Dimensions Length Width Area
inches inches sq. ft
74 41 21.07
Interior Zone 72 in
Edge Zone 72 in
Attachment area = 18.5 18.5 ft2
Load per attachment = 319 414 lbs
See following page for manufacturer's allowable attachment uplift load
Therefore the manufacturer's spacings are ok for the loads
Enclosed
Uplift
Wind Pressure
Manufacturer Spacing Information
ݍ = .00256 כ ܭ௭ כ ܭ௭௧ כ ܭௗ כ ܸ ଶ
4 of 11
WILSHIRE MINNIE
ROOFTOP PV
Project No. 21-001
6/26/25
5 of 11
WILSHIRE MINNIE
ROOFTOP PV
Project No. 21-001
6/26/25
ROOFTOP SOLAR PANELS PARALLEL TO THE ROOF SURFACE PER ASCE 7-16 29.4.4
Roof Mounted PV Attachment Calculations
p = q h (GC p )(E )(a )
Kz =0.62 ASCE7 Table 26.10-1
Kzt =1.00
Kd =0.85 ASCE7 Table 26.6-1
V =95 mph
Exposure =B
qz =12.3 psf (Ultimate)
Building Type:
Surface Type: Roof
Roof Angle : 2
Roof Height: 20 ft Height of Canopy
E=1.5
a=0.8
1, 2e 2r, 2n
GC:-1.6 -2.13
-23 -31.3 psf (Ultimate)
-13.8 -18.8 psf (Working Stress)
Module Dimensions Length Width Area
inches inches sq. ft
74 41 21.07
Interior Zone 72 in
Edge Zone 72 in
Attachment area = 18.5 18.5 ft2
Load per attachment = 256 347 lbs
See following page for manufacturer's allowable attachment uplift load
Therefore the manufacturer's spacings are ok for the loads
Enclosed
Uplift
Wind Pressure
Manufacturer Spacing Information
ݍ = .00256 כ ܭ௭ כ ܭ௭௧ כ ܭௗ כ ܸ ଶ
6 of 11
WILSHIRE MINNIE
ROOFTOP PV
Project No. 21-001
6/26/25
7 of 11
WILSHIRE MINNIE
ROOFTOP PV
Project No. 21-001
6/26/25
Check Building for PV
Roof Loads weight (psf) Wall Loads weight (psf)
Roofing 4.4 Stucco 10
15/32" Sheathing 1.5 15/32" sheathing 1.5
Roof Trusses 3 2x6 @ 16"oc 1.5
Insulation 1.0 Gypboard 1.8
Fire Sprinklers 1.0 Misc 1.2
Girders 1.5 Wall Total Weight 16 psf
Ceiling 1.8
Mechanical 1.5
Misc.1.3
Total 17.0 psf
PV Weight 3.0 psf
System Total 20.0
Check existing structure per California Existing Building Code Section 503.3 and 503.4
Vertical Capacity (CEBC 503.3)
Lateral Capacity (CEBC 503.4)
Building Areas (Worst Case)
Building #1225
Roof Area 3024 ft2
Wall Area 500 ft2
PV Area 1609 ft2
Wind Check
The modules are mounted parallel to the roof, therefore the wind loading will not change.
Seismic Check
Existing 59408 lbs
Solar Weight 4826 lbs
New Total Weight 64234 lbs
Percentage Change 8.1%
Total increase in weight to the structure is less than 10%, therefore the existing structure is ok
Modules may not be walked on after installation. The live load on the roof is replaced with the dead load of
the PV system. This is less than the live load, therefore the vertical system is ok to support the system.
Photos of the existing roof were reviewed to look for signs of potential distress in the roof or poor drainage
which increasing the load on the roof would make worse. The photos showed that the roof appeared to be
in good condition without signs of damage or significant ponding. Based on this observation as well as the
live load offset, the roof is sufficient to support the proposed PV system.
8 of 11
SS : 1.279
S1 : 0.457
F a : 1.2
F v : N/A
SMS : 1.535
SM1 : N/A
SDS : 1.023
SD1 : N/A
T L : 8
PGA : 0.539
PGA M : 0.647
F PGA : 1.2
Ie : 1
C v : 1.356
Seismic
Site Soil Class:
Results:
Data Accessed:
Date Source:
D - Default (see Section 11.4.3)
USGS Seismic Design Maps
Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8.
Wed Jun 25 2025
Page 2 of 3https://ascehazardtool.org/Thu Jun 26 2025
9 of 11
The ASCE Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any
kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or
has been extrapolated from maps incorporated in the ASCE standard. While ASCE has made every effort to use data obtained from reliable
sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or
quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation,
relationship, or sponsorship of such third-party content by or from ASCE.
ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent
professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such
professionals in interpreting and applying the contents of this Tool or the ASCE standard.
In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors,
employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential
damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by
law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data
provided by the ASCE Hazard Tool.
Page 3 of 3https://ascehazardtool.org/Thu Jun 26 2025
10 of 11
WILSHIRE MINNIE
ROOFTOP PV
Project No. 21-001
6/26/25
Site Class=D-Default
Seismic Design Category=D (ASCE Table 11.6-1)
Importance Factor (IE) =1.00 (ASCE Table 1.5-2)
Mapped Spectral Response acceleration @ short period (SS)=1.279 from OSHPD website
Site Coefficient (Fa)=1.2 from OSHPD website
Maximum Considered Spectral Response acceleration, short period (SMS)=1.535 (ASCE 11.4-1)
Design Spectral Response acceleration @ short period (SDS)=1.023 (ASCE 11.4-3)
Mapped Spectral acceleration @ 1-second period (S1)=0.457 from OSHPD website
Site Coefficient (Fv)=1.84 (ASCE Table 11.4-2)
Maximum Considered Spectral acceleration @ 1-second period (SM1)=0.842 (ASCE 11.4-2)
Spectral acceleration @ 1-second period (SD1)=0.562 (ASCE 11.4-4)
Long Period Transition Period (TL)=8 (ASCE Fig. 22-14)
Short Period Transition Period (Ts)=0.55 (ASCE 11.4.6)
Risk Category (Ie)=II (ASCE Table 1.5-2)
Seismic Response Modification Factor (R)=6.50 (ASCE Table 12.2-1)
Equivalent Lateral Force Procedure:[ASCE Section 12.8.1 ]
Cs, max= 0.768
Cs, min=0.045 шϬ͘Ϭϭ
Cs =0.157
10.0
0.020
0.75
0.112
V= 0.157 W (ULTIMATE)
V= 0.110 W (ASD)
SEISMIC DESIGN, ASCE 7-16
Story Height (hn) =
Building Period Coefficient (Ct) =
Exponent (x) =
Fundamental Period (Ta) =(ASCE 12.8.2.1)
11 of 11