HomeMy WebLinkAbout2344 N Fairmont Ave - REV 2 - PlanI. PROJECT DATA: 1. PROJECT LOCATION: 2344 FAIRMONT AVENUE, SANTA ANA 3. APPLICABLE CODES: CALIFORNIA CODE OF REGULATIONS LIST OF CALIFORNIA CODE OF REGULATIONS (C.C.R.): PART 1 2022 BUILDING STANDARDS ADMINISTRATIVE CODE, TITLE 24 C.C.R. PART 2 2022 CALIFORNIA BUILDING CODE, TITLE 24 C.C.R. PART 2.5, 2022 CALIFORNIA RESIDENTIAL CODE (CRC), WHICH IS BASED ON THE 2021 INTERNATIONAL RESIDENTIAL CODE (IRC) PUBLISHED BY THE INTERNATIONAL CODE COUNCIL (ICC). THIS IS A COMPLETELY NEW PART OF T-24 PART 3 2022 CALIFORNIA ELECTRICAL CODE (CEC), TITLE 24 C.C.R. WHICH IS BASED ON THE 2020 NATIONAL ELECTRICAL CODE AND 2022 CALIFORNIA AMENDMENTS) CODE OF THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) PART 4 2022 CALIFORNIA MECHANICAL CODE (CMC), TITLE 24 C.C.R. BASED ON THE 2021 UNIFORM MECHANICAL CODE OF THE INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS, (IAPMO) PART 5 2022 CALIFORNIA PLUMBING CODE (CPC), TITLE 24 C.C.R. WHICH IS BASED ON THE 2021 UNIFORM PLUMBING CODE OF THE INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS, IAPMO) PART 6 2022 CALIFORNIA ENERGY CODE, TITLE 24 C.C.R.. PART 9 2022 CALIFORNIA FIRE CODE, TITLE 24 C.C.R. PART 10 2022 CALIFORNIA EXISTING BUILDING CODE, TITLE 24 C.C.R. PART 11 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN CODE). TITLE 24 C.C.R. CITY OF SANTA ANA MUNICIPAL CODE REQUIREMENTS 2. DESCRIPTION OF WORK: DEMOLITION OF EXISTING ALUMINUM PATIO ENCLOSURE. NEW FAMILY ROOM ADDITION IN EXISTING FOOTPRINT. DEMOLITION AND REPLACEMENT OF EXISTING CHIMNEY 4. DESIGNER: LINDSAY L A THOMPSON IV 1598 CAMELOT DRIVE, CORONA, CA 92882 T: 714-504-2544 5. STRUCTURAL ENGINEER VCA ENGINEERS YOUNG K. NAM, P.E, S.E LICENSE # S4029 2151 MICHELSON DR. #240, iRVINE, CA 92612 T: 949-679-0870 PROJECT NUMBER: A P R O J E C T F O R : CHECKED: DRAWN: ISSUE/REVISION: DE S I G N E R : LI N D S A Y L A T H O M P S O N I V 15 9 8 C A M E L O T D R I V E , CO R O N A , C A , 9 2 8 8 2 PH O N E : 7 1 4 - 5 0 4 - 2 5 4 4 5/ 6 / 2 0 2 6 1 1 : 4 0 : 1 5 A M C : \ U s e r s \ l t h o m p s o n \ O n e D r i v e - C an n o n D e s i g n \ C D H o m e \ D o c u m e n t s \ i m p o r t a n t d o c s \ P a r e n t s h o u s e \ T h o m p s o n _ R 2 2 . r v t LT201801 00 - A 0 . 0 T I T L E S H E E T Th o m p s o n R e s i d e n c e Th o m p s o n , L i n d s a y & B o n n i e LLATIV LLATIV 00-A0.0 TITLE SHEET 5/15/2025 CITY SUBMITTAL 23 4 4 N . F a i r m o n t A v e n u e , Sa n t a A n a , C A 9 2 7 0 6 PROPERTY OWNER: LINDSAY & BONNIE THOMPSON PROJECT ADDRESS: 2344 N. FAIRMONT AVENUE ZONE: R1 (SINGLE FAMILY RESIDENTIAL) APN: 003-091-08 OCCUPANCY TYPE: R-3 CONSTRUCTION TYPE: V-B SPRINKLER: NONE EXISTS NUMBER OF STORIES: ONE CLIMATE ZONE: 8 GENERAL PLAN: LR 7.0 LOT SIZE: 6,750 SQ FT BUILDING SIZE: EXISTING STRUCTURE: 1,471 SQ FT ADDITION: 343 SQ FT GARAGE: 323 SQ FT TOTAL: 2,137 SQ FT LOT COVERAGE: 31.6% OPEN SPACE: 4,613 SQ FT THOMPSON RESIDENCE - FAMILY ROOM ADDITION 2344 N. FAIRMONT AVENUE, SANTA ANA, CA 92706 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2022 CALIFORNIA BUILDING, PLUMBING, MECHANICAL AND ELECTRICAL CODES, AND LOCAL ORDINANCES LISTED 2. VERIFY ALL DIMENSIONS, DO NOT SCALE DRAWINGS 3. ULTIMATE CONCRETE STRENGTH TO BE 3,000 PSI @ 28 DAYS 4. LUMBER: USE DOUGLAS FIR COMMERCIAL GRADE #1 FOR ALL POSTS AND 6X LARGER BEAMS AND COMMERCIAL GRADE #2 FOR ALL 4X AND SMALLER, ALL LUMBER SHALL BE GRADE MARKED. 5. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT IN CONJUCTION WITH THE PRODUCTION OF THIS WORK. 6. COMPLIANCE SHALL BE MADE WITH THE STATE'S ENERGY CONSERVATION REQUIREMENTS. FIEL REQUIRED DOCUMENTATION ON THE DRAWINGS. 7. DRAWINGS AND WORK MUST SHOW COMPLIANCE WITH GENERAL AND CONVENTIONAL CONSTRRUCTION REQUIREMENTS OF CBC SECTIONS 2308 AND CHAPTER 18 FOUNDATION REQUIREMENTS. GENERAL NOTES PROPERTY NOTES SHEET INDEX SHEET NO. SHEET NAME ISSU E NO. 1 0 3 / 2 8 / 2 0 2 4 - I S S U E # 1 ISS UE NO. 2 0 5 / 1 5 / 2 0 2 5 - I S S U E # 2 GENERAL 00-A0.0 TITLE SHEET Yes ● Yes ● 00-A0.1 EXISTING PICTURES AND ELEVATIONS Yes ● Yes ● 00-A0.2 EXISTING AND NEW SITE PLANS Yes ● Yes ● ARCHITECTURAL 01-A1.0 DEMOLITION AND CONSTRUCTION PLANS Yes ● Yes ● 01-A2.0 INTERIOR AND EXTERIOR ELEVATIONS AND SECTIONS Yes ● Yes ● 01-A3.0 WALL SECTIONS Yes ● Yes ● 01-A4.0 DETAILS Yes ● Yes ● 01-A5.0 WINDOW AND DOOR SCHEDULES Yes ● STRUCTURAL 02-S001 GENERAL NOTES Yes ● Yes ● 02-S101 TYPICAL DETAILS Yes ● Yes ● 02-S102 TYPICAL DETAILS Yes ● Yes ● 02-S103 TYPICAL DETAILS Yes ● Yes ● 02-S201 FOUNDATION & FRAMING PLAN Yes ● Yes ● 02-S301 TYPICAL DETAILS Yes ● Yes ● 02-S401 FRAMING DETAILS Yes ● Yes ● ENERGY 03-T24.1 TITLE 24 ENERGY COMPLIANCE FORMS No Yes ● 03-T24.2 TITLE 24 ENERGY COMPLIANCE FORMS No Yes ● PROJECT DATA: THE EXISTING SINGLE FAMILY RESIDENCE HAS AN ALUMINUM ENCLOSURE ERECTED IN THE BACK OF THE HOUSE THAT IS TO BE DEMOLISHED. THE EXISTING CONCRETE PAD IS TO REMAIN EXCEPT WHERE NOTED TO BE DEMOLISHED FOR THE NEW FOOTINGS. A NEW FAMILY ROOM IS TO BE BUILT WITHIN THE EXISTING FOOTPRINT. THERE IS AN EXISTING STAIR ACCESS TO THE CELLAR/BASEMENT THAT HOUSES THE MECHANICAL EQUIPMENT WHICH IS TO REMAIN. A NEW PLATFORM WITH HIDDEN DOOR IS TO CONCEAL THE ACCESS. THE REMAINING FLOOR IS TO BE COVERED WITH SALTILO TILE AND A NEW GAS FIRE PLACE IS TO BE INSTALLED. SALVAGED WINDOWS ARE TO BE INSTALLED TO ALIGN WITH THE HISTORIC CHARACTER OF THE EXISTING BUILDING. THE EXISTING BRICK CHIMNEY IS PULLING AWAY FROM THE LIVING ROOM WALL. THE WALL FRAMING WHICH SUPPORTS AN EXISTING BUILT-IN THAT SURROUNDS THE HEARTH IS ALL TO REMAIN. A NEW WOOD FRAMED FAUX CHIMNEY IS TO BE INSTALLED TO MATCH THE EXISTING. A NEW GAS FIREPLACE IS TO BE INSTALLED WITHIN THE WOOD FRAMED HEARTH. A NEW FOOTING IS TO BE INSTALLED UNDER THE EXISTING PORTION OF ADJACENT WALLS AS WELL AS FOR THE NEW FRAMED FIREPLACE TO TIE IT ALL TOGETHER. SCOPE OF WORK VICINITY MAP 05/15/2025 BLDG DEPT RESUBMITTAL 05/06/2026 Revision 2 1 1 Revision Description: Revision 1 (Previous Approved): Request by owner to value engineer the structure to deal with rising project costs including but not limited to removing beams, supporting columns and 2x T&G ceiling/deck and replacing with smaller beams, conventional ceiling framing and 1x T&G ceiling Revision 2: Approved assumed existing footing condition found to be less than expected which required review and modification by the structural engineer to comply with minimum requirements indicated 3 GENERAL NOTES: 1. DETAILS OF CONSTRUCTION NOT SHOWN SHALL BE OF SAME NATURE AS THOSE SHOWN FOR SIMILAR CONDITIONS. REFER TO THE TYPICAL DETAIL SHEETS FOR TYPICAL DETAILS OF CONSTRUCTION. TYPICAL DETAILS APPLY TO ALL CONSTRUCTION UNLESS SPECIFICALLY NOTED OR SHOWN OTHERWISE. WHERE CONDITIONS REQUIRE MODIFICATIONS OF A TYPICAL DETAIL, THE CONTRACTOR SHALL SUBMIT MODIFIED DETAIL FOR APPROVAL BY THE ENGINEER OF RECORD PRIOR TO FABRICATION AND INSTALLATION. DETAILS OF CONSTRUCTION NOT SHOWN SHALL BE OF SAME NATURE AS THOSE SHOWN FOR SIMILAR CONSTRUCTION. 2. CONTRACTOR SHALL CONSIDER THE PROJECT SPECIFICATIONS A PART OF THE CONTRACT DOCUMENTS. WHERE INFORMATION IS CONFLICTING, SPECIFIC DETAILS SHALL GOVERN OVER TYPICAL DETAILS WHICH SHALL GOVERN OVER THESE NOTES WHICH SHALL GOVERN OVER SPECIFICATIONS. 3. REFER TO THE PROJECT SPECIFICATIONS FOR SHOP DRAWING REQUIREMENTS AND SUBMITTALS. 4. ALL DIMENSIONS ON STRUCTURAL DRAWINGS SHALL BE CHECKED AGAINST ARCHITECTURAL DIMENSIONS. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE OMITTED OR NOT CLEAR, CONTACT THE ARCHITECT (ARCH) OR STRUCTURAL ENGINEER OF RECORD (SEOR). ALL DIMENSIONS RELATED TO EXISTING CONDITIONS SHALL BE FIELD VERIFIED BY THE CONTRACTOR. DIMENSIONS ARE TO THE FACE OF STUDS, AND TO CENTERLINE OF COLUMNS UNO. 5. IT IS THE CONTRACTOR'S RESPONSIBILITY TO IMMEDIATELY NOTIFY THE SEOR OF ANY CONFLICTS BETWEEN THE STRUCTURAL DRAWINGS AND OTHER DRAWINGS; OR EXISTING CONDITIONS NOT SHOWN OR DIFFERENT FROM THOSE SHOWN ON DRAWINGS PRIOR TO COMMENCEMENT OF WORK. THE CONTRACTOR IS NOT TO ORDER MATERIAL OR CONSTRUCT ANY PORTION OF THE BUILDING THAT IS IN CONFLICT UNTIL THE CONFLICT IS RESOLVED WITH THE AFFECTED PARTIES. 6. THE STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. UNLESS OTHERWISE SHOWN THEY DO NOT INDICATE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE CONSTRUCTION AND ALL ADJACENT PROPERTIES DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE BUT ARE NOT LIMITED TO BRACING, SHORING OF LOADS DUE TO CONSTRUCTION EQUIPMENT, ETC. OBSERVATION VISITS TO THE SITE BY THE ARCHITECT OR SEOR SHALL NOT INCLUDE OBSERVATION OF THE ABOVE ITEMS. 7. SUBSTITUTION REQUESTS FOR MATERIALS SPECIFIED ON THE STRUCTURAL DRAWINGS MAY BE CONSIDERED WITH MATERIALS HAVING EQUIVALENT OR GREATER CAPACITY AND PERFORMANCE. CURRENT EVALUATION REPORTS AND PRODUCT INFORMATION SHALL BE PROVIDED TO THE STRUCTURAL ENGINEER DEMONSTRATING THE REQUIRED CAPACITY AND PERFORMANCE OF THE MATERIAL TO BE SUBSTITUTED. WRITTEN APPROVAL FROM THE SEOR AND DSA SHALL BE OBTAINED PRIOR TO THE SUBSTITUTION OF ANY MATERIAL SPECIFIED ON THE STRUCTURAL DOCUMENTS. 8. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPLY WITH THE PERTINENT SECTIONS OF THE "CONSTRUCTION SAFETY ORDERS" ISSUED BY THE STATE OF CALIFORNIA, LATEST EDITION, AND ALL OSHA REQUIREMENTS AS THEY APPLY TO THIS PROJECT. THE ARCHITECT, SEOR AND DSA, AND THE OWNER DO NOT ACCEPT ANY RESPONSIBILITY FOR THE CONTRACTOR'S FAILURE TO COMPLY WITH THESE REQUIREMENTS. 9. NOT USED 10. CONSTRUCTION MATERIALS SHALL BE DISTRIBUTED WHEN PLACED ON THE STRUCTURE SUCH THAT LOADS DO NOT EXCEED DESIGN LIVE LOADS OR RESULT IN AN UNBALANCED CONDITION. STRUCTURAL DESIGN CRITERIA: 1. CODES: ALL WORK SHALL BE IN CONFORMANCE WITH THE CALIFORNIA BUILDING CODE (CBC) 2022 EDITION, INCLUDING ALL AMENDMENTS. ALL STANDARDS USED SHALL BE THE LATEST VERSION APPROVED BY THE CODE ENFORCEMENT AGENCY ON THE DATE OF THE PERMIT ISSUANCE UNLESS SPECIFICALLY NOTED OTHERWISE. 2. SEISMIC DESIGN INFORMATION: 3. WIND DESIGN INFORMATION: 4. LIVE LOADS RESIDENTIAL: 40 PSF ROOF: 20 PSF BASIC WIND SPEED V = 95 MPH (3 SEC GUST) EXPOSURE C I = 1.0 OCCUPANCY CAT. II SITE CLASS D (DEFAULT) SS = 1.323 S1 = 0.471 SDS = 1.508 SD1 = 0.532 SEISMIC DESIGN CATEGORY = D R = 6.5 Cd = 4 Ω Kz = 0.85 Kd = 0.85 AB ANCHOR BOLT ABV ABOVE ADDT'L ADDITIONAL ADJ ADJACENT AFF ABOVE FINISH FLOOR ALT ALTERNATE ARCH ARCHITECT(URAL) BLDG BUILDING BLKG BLOCKING BLW BELOW BM BEAM BN BOUNDARY NAILING B.O. BOTTOM OF BOTT BOTTOM BRG BEARING BS BOTH SIDES BTWN BETWEEN C CAMBER CIP CAST IN PLACE CJ CONTROL/ CONSTRUCTION JOINT CL CENTERLINE CLR CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONN CONNECTION CONT CONTINUOUS CP COMPLETE PENETRATION CSK COUNTERSINK CTR(D) CENTER(ED) D BAR OR BOLT DIAMETER DBL DOUBLE DEMO DEMOLITION DET DETAIL DIA DIAMETER DIAG DIAGONAL DIM DIMENSION DO DITTO DWG DRAWING (E) EXISTING EA EACH EF EACH FACE EJ EXPANSION JOIST EMBED EMBEDMENT ELEC ELECTRICAL ELEV ELEVATION EN EDGE NAILING E.O. EDGE OF EOR ENGINEER OF RECORD EQ EQUAL EQUIP EQUIPMENT ES EACH SIDE OR EDGE SCREW EW EACH WAY EXP EXPANSION EXT EXTERIOR FIN FINISH FLR FLOOR FN FIELD NAILING FND FOUNDATION F.O. FACE OF FS FAR SIDE OR FIELD SCREW FRMG FRAMING FT FOOT OR FEET FTG FOOTING G GIRDER GA GAGE GALV GALVANIZED HAB HEADED ANCHOR BOLT HD HOLDDOWN HDR HEADER HGR HANGER HK HOOK HORIZ HORIZONTAL HP HIGH POINT HS HIGH STRENGTH HSS HOLLOW STRUCTURAL STEEL HT HEIGHT IN INCH INT INTERIOR JST JOIST KLF KIPS PER LINEAR FOOT KSL KIPS PER SQUARE FOOT KSI KIPS PER SQUARE INCH L ANGLE LFRS LATERAL FORCE RESISTING SYSTEM LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LP LOW POINT LWC LIGHTWEIGHT CONCRETE MAX MAXIMUM MB MACHINE BOLT MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM MTL METAL (N) NEW NS NEAR SIDE OR NON-SHRINK NTS NOT TO SCALE NWC NORMAL WEIGHT CONCRETE OC ON CENTER O.F. OUTSIDE FACE OH OPPOSITE HAND OPNG OPENING PDF POWDER DRIVEN FASTENER PJ PANEL JOIST PL PLATE PLC(S) PLACE(S) PLF POUND PER LINEAR FOOT PLYWD PLYWOOD PREFAB PREFABRICATED PSF POUND PER SQUARE FOOT PSI POUND PER SQUARE INCH PT PRESSURE TREATED OR POST TENSION QTY QUANTITY RAD, R RADIUS REF REFERENCE REINF REINFORCING REQD REQUIRED SB SILL BOLT SC SAW CUT OR SLIP CRITICAL SCHED SCHEDULE SEOR STRUCTURAL ENGINEER ON RECORD SHTG SHEATHING SIM SIMILAR SMS SHEET METAL SCREW SN SILL NAIL SOG SLAB ON GRADE SQ SQUARE SS STAINLESS STEEL STD STANDARD STGRD STAGGERED STIFF STIFFENER STL STEEL STRUCT STRUCTURAL T&B TOP AND BOTTOM THK THICK T.O. TOP OF TOM TOP OF MASONRY TOS TOP OF STEEL TYP TYPICAL UNO UNLESS NOTED OTHERWISE VERT VERTICAL W/ WITH W/O WITHOUT WF WIDE FLANGE WLD WELDED WO WHERE OCCURS WP WORK POINT WT WEIGHT WWF WELDED WIRE FABRIC Ø = DIAMETER = REFERENCE ELEVATION OR WORK POINT TYPICAL ABBREVIATIONS 1. FIELD VERIFY ALL CONDITIONS & DIMENSIONS PRIOR TO SHOP DRAWING PRODUCTION AND FABRICATION OF STRUCTURAL ELEMENTS. 2. WHERE ALL OTHER EXISTING CONDITIONS VARY SIGNIFICANTLY FROM THOSE SHOWN ON THESE DRAWINGS, THE STRUCTURAL ENGINEER SHALL BE NOTIFIED PRIOR TO CONTINUED CONSTRUCTION RELATED TO SUBJECT CONDITIONS. 3. SHORE ALL EXISTING CONSTRUCTION AS REQUIRED. EXISTING CONDITIONS NOTES: 1. THE ARCHITECT AND ENGINEERS ARE NOT RESPONSIBLE FOR THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES WHETHER OR NOT SHOWN ON THE DRAWINGS. THE LOCATION OF ANY EXISTING UNDERGROUND UTILITIES SHOWN ON THE DRAWINGS ARE APPROXIMATE. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER SHOULD ANY SUCH UNIDENTIFIED CONDITIONS BE DISCOVERED. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGES WHICH MAY RESULT FROM HIS FAILURE TO EXACTLY LOCATE AND PRESERVE ALL EXISTING UNDERGROUND UTILITIES. EXISTING UNDERGROUND UTILITY NOTES: 1. REINFORCING GRADES FOR CONCRETE OR MASONRY: A. ALL BARS EXCEPT THOSE TO BE WELDED.............. ASTM A615, GRADE 60 B. TIES AND STIRRUPS .................................................. ASTM A615, GRADE 60 C. WELDED WIRE FABRIC ........................................... ASTM A185 D. ALL BARS TO BE WELDED ........................................ ASTM A706, GRADE 60 2. MAINTAIN MINIMUM CONCRETE COVER FROM FACE OF CONCRETE TO EDGE OF ALL REINFORCEMENT AS FOLLOWS (UNO): PROVIDE THE LARGEST COVER REQUIRED FOR ALL APPLICABLE CONDITIONS. WHERE #3 STIRRUPS OR TIES ARE USED, ENSURE THAT THE COVER FOR LONGITUDINAL BARS IS ADEQUATE. 3. REINFORCEMENT SHALL BE PLACED IN ACCORDANCE WITH THE CONCRETE REINFORCING STEEL INSTITUTE (CRSI) "MANUAL OF STANDARD PRACTICE". EACH REINFORCING BAR SHALL BE WIRED TO A CROSS BAR AT A MAXIMUM SPACING OF 24" OC. PROVIDE ALL ACCESSORIES NECESSARY TO SUPPORT REINFORCING IN POSITIONS SHOWN ON THE PLANS. 4. SPLICES IN CONTINUOUS REINFORCEMENT, SHALL HAVE A CLASS "B" LAP (1'-6" MIN) AND THE SPLICES IN ADJACENT BARS SHALL BE NOT LESS THAN 5'-0" APART. BARS MAY BE WIRED TOGETHER AT SPLICES OR LAPS EXCEPT FOR TOP REINFORCING OF BEAMS AND SLABS OR WHERE SPECIFICALLY DETAILED TO BE SEPARATED. WELDED WIRE FABRIC SHALL BE LAPPED 12" MINIMUM. 5. ALL DOWELS, ANCHOR BOLTS AND OTHER HARDWARE TO BE SET IN CONCRETE SHALL BE TIED IN PLACE PRIOR TO PLACEMENT OF CONCRETE. NO WET SETTING, STABBING, RODDING OR OTHER MOVEMENT OF EMBEDDED ITEMS SHALL BE PERFORMED DURING PLACEMENT OF CONCRETE. 6. BEND REINFORCING BARS COLD. 7. STEEL SHALL BE KEPT CLEAN AND FREE OF RUST. 8. DOWELS BETWEEN FOOTING AND WALLS OR COLUMNS SHALL BE THE SAME GRADE, SIZE AND SPACING AS THE MAIN REINFORCING UNO. 9. ALL BARS SHALL BE MARKED SO THEIR IDENTIFICATION CAN BE MADE WHEN THE FINAL IN PLACE INSPECTION IS MADE. 10. CHAIRS OR SPACERS FOR REINFORCING SHALL BE NON-FERROUS OR PLASTIC COATED WHEN RESTING ON EXPOSED SURFACES. CONDITION COVER CONCRETE POURED AGAINST EARTH 3" CONCRETE POURED IN FORMS AND EXPOSED TO WEATHER OR EARTH - #6 BARS AND LARGER 2" - #5 BARS AND SMALLER 1 1/2" STRUCTURAL SLABS ON GRADE - FROM BOTTOM OF SLAB 2" - FROM TOP OF SLAB 1 1/2" OTHER CONCRETE NOT EXPOSED TO WEATHER OR EARTH FOR #11 BARS AND SMALLER REINFORCING STEEL NOTES: 3/4" 1. CONCRETE SHALL BE MIXED, PLACED AND CURED IN ACCORDANCE WITH ACI 318, 2019 EDITION, AND PROJECT SPECIFICATIONS. 2. CONCRETE SHALL NOT BE DROPPED THROUGH REINFORCING STEEL (AS IN WALLS) SO AS TO CAUSE SEGREGATION OF AGGREGATES. IN SUCH CASES, HOPPERS AND VERTICAL CHUTES OR TRUNKS SHALL BE USED. CHUTES OR TRUNKS SHALL BE OF VARIABLE LENGTHS SO THAT FREE UNCONFINED FALL OF CONCRETE SHALL NOT EXCEED SIX FEET. A SUFFICIENT NUMBER OF CHUTES OR TRUNKS SHALL BE USED TO ENSURE THE CONCRETE IS KEPT LEVEL AT ALL TIMES. 3. CONSTRUCTION JOINTS SHALL BE CLEANED AND ROUGHENED BY REMOVING THE ENTIRE SURFACE TO EXPOSE CLEAN AGGREGATE SOLIDLY EMBEDDED IN THE MORTAR MATRIX. SEE PLANS AND DETAILS FOR LOCATION AND TYPE OF CONSTRUCTION JOINT. LOCATIONS OF ADDITIONAL CONSTRUCTION JOINTS NOT SHOWN ON THESE PLANS SHALL BE SUBMITTED FOR APPROVAL BY THE EOR PRIOR TO PLACING ANY CONCRETE. 4. STRUCTURAL CONCRETE SHALL MEET THE FOLLOWING DESIGN CRITERIA: a. MAXIMUM DRY WEIGHT OF LIGHTWEIGHT CONCRETE SHALL BE 110 PCF, UNLESS APPROVED BY SEOR. b. SLUMP MEASURED PRIOR TO SUPERPLASTICIZER, WHERE OCCURS. c. USE TYPE II/V CEMENT. 5. CONCRETE MIX DESIGN AND TESTING SHALL MEET THE REQUIREMENTS OF THE BUILDING CODE, AND SPECIFICATIONS. ALL CONCRETE MIXES SHALL BE DESIGNED BY A RECOGNIZED TESTING LAB STAMPED AND SEALED BY A LICENSED CALIFORNIA CIVIL ENGINEER AND SUBMITTED TO THE SEOR FOR REVIEW PRIOR TO CONCRETE PLACEMENT. STRUCTURAL CONCRETE MIXES SHALL CONSIST OF 5 SACK MINIMUM UNO. 6. AGGREGATES IN NORMAL WEIGHT CONCRETE SHALL CONFORM TO ASTM C-33 (HARDROCK). AGGREGATES IN LIGHT WEIGHT CONCRETE SHALL CONFORM TO ASTM C-330. 7. COMPRESSIVE STRENGTH TEST REPORTS SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT AND THE SEOR. 8. PORTLAND CEMENT SHALL BE TYPE II/V FOR ALL CONCRETE CONFORMING TO ASTM C150, LOW ALKALI. MILL TESTS WITH CERTIFICATES OF COMPLIANCE SHALL BE SUBMITTED. 9. FLY ASH OR OTHER POZZOLANS CONFORMING TO ASTM C618 CLASS N OR F MAY BE USED AS A PARTIAL SUBSTITUTION FOR PORTLAND CEMENT UP TO A MAXIMUM OF 15% TOTAL CEMENTITIOUS MATERIALS BY WEIGHT IF THE MIX DESIGN IS PROPORTIONED PER ACI 318, SECTION 5.3. 10. CONCRETE MIXING OPERATIONS, ETC. SHALL CONFORM TO ASTM C94. 11. NOT USED. 12. DRYPACK OR NONSHRINK GROUT SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 2 TIMES THE SUPPORTING CONCRETE STRENGTH, AND SHALL BE OF MASTERFLOW 713, FIVE STAR GROUT, SIKA GROUT 212, EMBECO 636, OR APPROVED EQUAL. FOR THICK GROUT LAYERS FOLLOW MANUFACTURER'S GUIDELINES TO ATTAIN THE REQUIRED STRENGTH, WHICH MAY INCLUDE THE ADDITION OF PEA GRAVEL. 13. DO NOT USE ANY CONCRETE OR GROUT CONTAINING CHLORIDES. WATER USED IN MIX SHALL BE CLEAN AND POTABLE. 14. PRIOR TO ERECTING ANY ELEMENTS THAT LOAD THE FOUNDATION, CONCRETE MUST REACH AN UNCONFINED COMPRESSION STRENGTH OF 2000 PSI MINIMUM AS DETERMINED BY TESTING OR PREVIOUSLY DOCUMENTED DATA FOR THE MIX DESIGN USED UNDER SIMILAR CONDITIONS, AND MUST BE ALLOWED TO CURE FOR A MINIMUM OF 3 DAYS. 15. FOR INTERIOR SLABS-ON-GRADE AND ALL OTHER SLABS RECEIVING ADHERED FLOORING FINISHES (I.E., GLUED, ETC.), THE MAXIMUM W/C RATIO SHALL NOT EXCEED 0.45. CURING COMPOUNDS USED ON CONCRETE THAT IS TO RECIEVE FINISHES SHALL BE COMPATIBLE WITH TILE AND ADHESIVES OR GROUTS IN ACCORDANCE WITH MANUFACTURER'S DATA AND BE APPROVED BEFORE USE. 16. MAINTAIN CONCRETE ABOVE 50 DEGREES FAHRENHEIT AND IN A MOIST CONDITION FOR A MINIMUM OF 7 DAYS AFTER PLACEMENT UNLESS OTHERWISE ACCEPTED BY SEOR. 17. SEE ARCHITECTURAL DRAWINGS FOR WALL OPENINGS, WALL OFFSETS, CHAMFERS, KERFS, DRIPS AND FOR EXTENT OF DEPRESSIONS, RAMPS, ETC. PROVIDE SLEEVES FOR ALL PIPES THROUGH CONCRETE WALLS AND FOOTINGS WHERE SHOWN ON THESE DRAWINGS. CORING IS NOT PERMITTED WITHOUT PRIOR APPROVAL BY THE SEOR AND DSA. 18. EXPOSED CORNERS OF SLABS, BEAMS, WALLS, COLUMNS, ETC. SHALL BE FORMED WITH 3/4" CHAMFER, UNO. STRUCTURAL CONCRETE NOTES: LOCATION CONC TYPE MAX AGGR. SIZE MAX W/C RATIO MAX SLUMP FOUNDATIONS 3000 PSI NWC 1 1/2" 0.45 4" SLAB ON GRADE 3000 PSI NWC 1" 0.45 4" ALL OTHER STRUCTURAL CONCRETE NOT NOTED ABOVE 3000 PSI NWC 1" 0.50 6" MIN 28-DAY COMP STRENGTH Kzt = 1 Rho = 1.0 INTERNAL PRESSURE COEFF. = +/- 0.18 DESIGN PROCEDURE: ELFP STATEMENT OF SPECIAL INSPECTIONS: 1. THE OWNER SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS TO PROVIDE INSPECTIONS DURING CONSTRUCTION. THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL DEMONSTRATE COMPETENCE, TO THE SATISFACTION OF THE BUILDING OFFICIAL, FOR INSPECTION OF THE PARTICULAR TYPE OF CONSTRUCTION OR OPERATION REQUIRING SPECIAL INSPECTION. 2. SPECIAL INSPECTIONS ARE NOT REQUIRED WHERE THE WORK IS DONE ON THE PREMISES OF A LA APPROVED FABRICATOR REGISTERED AND APPROVED TO PERFORM SUCH WORK WITHOUT SPECIAL INSPECTION. APPROVED FABRICATORS MUST SUBMIT A CERTIFICATE OF COMPLIANCE FOR OFFSITE FABRICATIONS SUCH AS STRUCTURAL STEEL, PRECAST CONCRETE, GLUED LAMINATED TIMBER, ETC. 3. ALL INSPECTIONS SHALL BE PERFORMED BY INDEPENDENT SPECIAL INSPECTORS. JOB SITE VISITS BY THE STRUCTURAL ENGINEER OR BUILDING OFFICIAL DO NOT CONSTITUTE AND ARE NOT A SUBSTITUTE FOR INSPECTIONS BY A SPECIAL INSPECTOR. 4. ALL INSPECTION REPORTS SHALL BE SUBMITTED TO THE BUILDING OFFICIAL AND SEOR. THE FINAL REPORTS BY THE SPECIAL INSPECTOR(S) MUST CERTIFY THAT THE ENTIRE STRUCTURAL SYSTEM COMPLIES WITH THE APPROVED PLANS AND SPECIFICATIONS. 5. IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO SEE THAT THESE INSPECTIONS ARE PERFORMED. 6. WORK REQUIRING SPECIAL INSPECTION SHALL BE INSPECTED BY THE SPECIAL INSPECTOR WHO IS PRESENT IN THE AREA WHERE THE WORK IS PERFORMED AND AT THE COMPLETION OF WORK. CONTINUOUS INSPECTION CONSISTS OF FULL-TIME INSPECTION; PERIODIC INSPECTION CONSISTS OF PART-TIME OR INTERMITTENT INSPECTION. 7. THE FOLLOWING SPECIAL INSPECTIONS ARE IN ADDITION TO INSPECTIONS BY THE BUILDING OFFICIAL. THIS LIST IS NOT INTENDED TO BE ALL INCLUSIVE. TABLE 1705.6 REQUIRED VERIFICATION AND INSPECTION OF SOILS VERIFICATION AND INSPECTION TASK CONTINUOUS DURING TASK LISTED PERIODICALLY DURING TASK LISTED 1.VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY. - X 2.VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL. - X 3.PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS.- X 4. VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESSES DURING PLACEMENT AND COMPACTION OF COMPACTED FILL. X - 5. PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE SUBGRADE AND VERIFY THAT SITE HAS BEE N PREPARED PROPERLY. - X TABLE 1705.3 REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION VERIFICATION AND INSPECTION CONT. PERIODIC REF. STANDARD CBC REF. 1.INSPECTION OF REINFORCING STEEL, INCLUDING PRESTRESSING TENDONS, AND PLACEMENT. -AIC 318: 3.5, 7.1-7.7 1913.4 2. INSPECTION OF REINFORCING STEEL WELDING IN ACCORDANCE WITH TABLE 1704A.3, ITEM 5B. - -AWS D1.4; ACI 318: 3.5.2 - 3. INSPECTION OF BOLTS TO BE INSTALLED IN CONCRETE PRIOR TO AND DURING PLACEMENT OF CONCRETE WHERE ALLOWABLE LOADS HAVE BEEN INCREASED OR WHERE STRENGTH DESIGN IS USED. X -ACI 318: 8.1.3, 21.2.8 1911.5, 1912.1 4.INSPECTION OF ANCHORS INSTALLED IN HARDENED CONCRETE.-ACI 318: 3.8.6, 8.1.3, 21.2.8 1912.1 5.VERIFYING USE OF REQUIRED DESIGN MIX.- X ACI 318: CH 4, 5.2-5.4 1904.2.2, 1913.2, 1913.3 6.AT THE TIME FRESH CONCRETE IS SAMPLED TO FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF THE CONCRETE. X - ASTM C172 ASTM C31; ACI 318: 5.6, 5.8 1913.10 7.INSPECTION OF CONCRETE AND SHOTCRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUES. X -ACI 318: 5.9, 5.10 1913.6, 1913.7, 1913.8 8. INSPECTION FOR MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES. -ACI 318: 5.11-5.13 1913.9 9.INSPECTION OF PRESTRESSED CONCRETE:X - A . APPLICATION OF PRESTRESSING FORCES.ACI 318: 18.20 - B . GROUTING OF BONDED PRESTRESSING TENDONS IN THE SEISMIC-FORECE-RESISTING SYSTEM. ACI 318: 18.18.4 - 10.ERECTION OF PRECAST CONCRETE MEMBERS.-ACI 318: CH 16 - 11.VERIFICATION OF IN-SITU CONCRETE STRENGTH, PRIOR TO STRESSING OF TENDONS IN POSTTENSIONED CONCRETE AND PRIOR TO REMOVAL OF SHORES AND FORMS FROM BEAMS AND STRUCTURAL SLABS. -ACI 318: 6.2 - 12.INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED. -ACI 318: 6.1.1 - FOR SI: 1 INCH = 25.4 MM A. WHERE APPLICABLE, SEE ALSO SECTION 1705.11, SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE. B. SPECIFIC REQUIREMENTS FOR SPECIAL INSPECTIONS SHALL BE INCLUDED IN THE RESEARCH REPORT FOR THE ANCHOR ISSUED BY AN APPROVED SOURCE IN ACCORDANCE WITH ACI 355.2 OR SHALL BE APPROVED BY THE BUILDING OFFICIAL PRIOR TO COMMENCEMENT OF THE WORK. C. INSTALLATION OFF ALL ADHESIVE ANCHORS IN THE HORIZONTAL AND UPWARDS INCLINED POSITIONS SHALL BE PERFORMED BY AN ACI/CRSI CERTIFIED ANCHOR INSTALLER. 1. ALL GRADES SPECIFIED ARE MINIMUM GRADES REQUIRED. 2. DOUGLAS FIR (DF) SHALL BE GRADED BY THE WESTERN WOOD PRODUCTS ASSOCIATION GRADING RULES, AND ASTM D245. 3. REDWOOD SHALL BE GRADED BY THE CALIFORNIA REDWOOD ASSOCIATION, REDWOOD INSPECTION SERVICE. 4. SILL PLATES SHALL BE PRESSURE-TREATED (PT) DOUGLAS FIR #1. REDWOOD IS PERMITTED WITH SEOR APPROVAL. 5. TOP PLATES, SILL PLATES, STUDS SHALL BE....................................DF #1 JOISTS, RAFTERS, PURLINS, BEAMS & POSTS SHALL BE ................DF #1 (UNO) LOAD BEARING STUDS SHALL BE.........................................................DF #1 6. MOISTURE CONTENT OF SAWN LUMBER SHALL NOT EXCEED 18% WHEN FRAMING STARTS OR SHEATHING IS APPLIED. ANY NONCOMPLIANT WORK SHALL BE REJECTED AND REFRAMED WITH ACCEPTABLE LUMBER. 7. TIMBERS 4" NOMINAL IN THE LEAST DIMENSION SHALL NOT CONTAIN BOXED HEART. 8. SILL PLATES SHALL BE PRESSURE-TREATED AND SHALL BE BOLTED TO CONCRETE WITH 5/8" DIAMETER ANCHOR BOLTS AT 32" OC MAX, UNO WITH A BOLT BETWEEN 4" TO 12" FROM THE END OF EACH PIECE OF SILL (2 BOLTS MIN EACH PIECE). PIECE OF SILL SHALL BE CONSIDERED ENDED WHERE PLATE IS CUT OUT OVER ONE-THIRD OF CROSS-SECTION. 9. ANCHOR BOLTS FOR NON-STRUCTURAL WALLS SUPPORTED ON SLABS SHALL HAVE 3 1/2" EMBEDMENT (UNO) MEASURED FROM TOP OF SLAB. 10. ANCHOR BOLTS FOR STRUCTURAL WALLS SHALL HAVE 12" EMBEDMENT (UNO) MEASURED FROM TOP OF SLAB. 11. STUD BEARING WALLS AND PARTITIONS SHALL HAVE DOUBLE TOP PLATES LAPPED AT WALL AND PARTITION INTERSECTIONS. JOINTS IN UPPER AND LOWER MEMBERS OF DOUBLE TOP PLATES SHALL BE STAGGERED AT LEAST 4'-0". 12. HOLES IN WOOD AND STEEL MEMBERS FOR BOLTS SHALL BE THE NOMINAL BOLT DIAMETER PLUS 1/16". 13. ALL BOLTS IN WOOD SHALL BE ASTM A307 STANDARD BOLTS, UNO. BOLTS AND SCREWS SHALL BE TIGHTENED AT TIME OF ERECTION AND RETIGHTENED BEFORE CLOSING IN OR AT THE COMPLETION OF THE JOB. 14. HOLES IN WOOD FOR LAG SCREW SHANK SHALL BE BORED TO THE SAME DIAMETER AND DEPTH AS THE SHANK, AND FOR THE THREADED PORTION BORED WITH A BIT NOT LARGER THAN 40% TO 70% OF THE SHANK DIAMETER. 15. LAG SCREWS AND SCREWS SHALL BE SCREWED AND NOT DRIVEN INTO PLACE. BOLT HOLES SHALL BE A MINIMUM OF 1/32" TO A MAXIMUM 1/16" LARGER THAN THE BOLT DIAMETER. HOLES SHALL BE ACCURATELY ALIGNED IN MAIN MEMBERS AND SIDE PLATES. BOLTS SHALL NOT BE FORCIBLY DRIVEN. 16. METAL FRAMING CONNECTORS SHALL BE MANUFACTURED BY SIMPSON STRONG TIE COMPANY (CURRENT CATALOG), OR "USP" WITH EQUIVALENT ICC PUBLISHED VALUES AND SHALL BE INSTALLED PER SPECIFICATIONS, NO EXCEPTIONS. 17. INSTALL WINDOWS AND DOORS IN STUD WALLS AFTER DEAD LOADS ARE APPLIED, AND PROVIDE A 1/2" SHIM SPACE AT THE HEAD CONDITION. 18. STEEL WASHERS SHALL BE PROVIDED UNDER HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS WHICH BEAR ON WOOD. STANDARD CUT WASHERS MAY BE USED IN ALL CASES EXCEPT SILL PLATES AND WOOD LEDGERS AGAINST CONCRETE OR MASONRY. NOTE, WASHERS UNDER CARRIAGE BOLT HEADS SHALL BE LARGE ENOUGH TO ALLOW FOR SQUARE SHOULDERS. 19. ONLY LOAD BEARING AND/OR SHEAR WALLS ARE SHOWN. SEE ARCHITECTURAL DRAWINGS FOR ALL OTHER PARTITIONS. 20. ELEVATIONS SHOWN ON PLANS ARE FROM FINISHED FIRST FLOOR, DATUM ELEVATION = 0'-0". 21. ALL EXTERIOR WALLS AND INTERIOR BEARING WALLS ARE 2x6 STUDS @ 16"OC TYPICAL, UNO. 22. ALL EXTERIOR STUD WALLS SHALL BE COMPLETELY SHEATHED WITH 15/32" APA RATED SHEATHING, EXPOSURE-1 (32/16). 23. INTERIOR STRUCTURAL SHEATHED WALLS ARE SHOWN ON PLANS AND SHALL HAVE 15/32" APA RATED SHEATHING EXPOSURE-1, (32/16),TYPICAL UNO. 24. ALL STRUCTURAL WALL SHEATHING IS SPLICED ON 2" NOMINAL BLOCKING AT HORIZONTAL JOINTS, UNO. 25. STRUCTURAL FLOOR AND ROOF SHEATHING SHALL BE AS SPECIFIED BELOW. NOTE: 1/8" GAP SHALL BE PROVIDED BETWEEN ADJACENT PANELS. PANELS WITH GRADE STAMP INDICATION "SIZED FOR SPACING" MAY BE USED TO FACILITATE THIS REQUIREMENT. SEE PLANS FOR REQUIRED BOUNDARY AND EDGE NAILING NOT LISTED BELOW. FLOOR SHEATHING SHALL BE GLUED AND NAILED PER PLAN. ( * - SHEATHING @ EXTERIOR DECKS SHALL BE EXTERIOR RATED PLYWOOD.) BN=BOUNDARY NAILING EN=EDGE NAILING FN=FIELD NAILING 26. SEE PLANS FOR LOCATION OF NOMINAL 2X FLAT BLOCKING AT ROOF SHEATHING PANEL JOINTS. SEE THIS SHEET FOR PLY CLIP REQUIREMENTS AT UNBLOCKED ROOF PANEL JOINTS. T&G SHEATHING IS NOT REQUIRED WHERE JOINTS ARE BLOCKED. 27. (S) INDICATES METAL FRAMING CONNECTORS MANUFACTURED BY SIMPSON STRONG TIE COMPANY (CURRENT CATALOG) OR "USP" WITH EQUIVALENT ICC PUBLISHED VALUES AND SHALL BE INSTALLED PER SPECIFICATIONS, NO EXCEPTIONS. ROUGH CARPENTRY/ WOOD NOTES: 1705.11.2 STRUCTURAL WOOD. CONTINUOUS SPECIAL INSPECTION IS REQUIRED DURING FIELD GLUING OPERATION OF ELEMENTS OF THE SEISMIC FORCE-RESISTING SYSTEM. PERIODIC SPECIAL INSPECTION IS REQUIRED FOR NAILING, BOLTING, ANCHORING AND OTHER FASTENING OF COMPONENTS WITHIN THE SEISMIC FORCE-RESISTING SYSTEM, INCLUDING WOOD SHEAR WALLS, WOOD DIAPHRAGMS, DRAG STRUTS, BRACES, SHEAR PANELS AND HOLD0DOWNS. WOOD LATERAL LOAD RESISTING SYSTEM SPECIAL INSPECTION: EXCEPTION: SPECIAL INSPECTION IS NOT REQUIRED FOR WOOD SHEAR WALLS, SHEAR PANELS AND DIAPHRAGMS, INCLUDING NAILING, BOLTING, ANCHORING AND OTHER FASTENING TO OTHER COMPONENTS OF THE SEISMIC FORCE0RESISTING SYSTEM, WHERE THE FASTENER SPACING IF THE SHEATHING IS MORE THAN 4INCHES (102MM) ON CENTER (O/C) FOUNDATION NOTES (NO SOILS REPORT): (UNLESS OTHERWISE NOTED ON PLANS) NAIL SPACING TO BE NOT LESS THAN REQUIRED PENETRATION. EDGE AND END DISTANCES SHALL BE NOT LESS THAN HALF THIS SPACING. ALL SPACING AND EDGE AND END DISTANCES SHALL BE SUCH AS TO AVOID SPLITTING OF THE WOOD. HOLES FOR NAILS, WHERE NECESSARY TO PREVENT SPLITTING, SHALL BE BORED OF A DIAMETER SMALLER THAN THAT OF THE NAILS. COMMON NAILS SHALL BE USED FOR NAILING AT TYPICAL CONNECTIONS NOTED BELOW (U.N.O.). FOR ALL CONNECTIONS OTHERWISE NOTED OR DETAILED ON PLANS, COMMON NAILS SHALL BE USED (SEE SCHEDULE BELOW). NAILING SCHEDULE SHORTENED 10d COMMON NAILS MAY BE USED TO FASTEN WOOD STRUCTURAL PANELS UNO. USE THE FOLLOWING MINIMUM LENGTHS: 10d x 2 1/4" FOR 15/32" OR THINNER PANELS, 10d x 2 3/8" FOR 19/32" PANELS, AND FULL LENGTH FOR 5/8" OR THICKER PANELS. NAIL TYPES SIZE DIAMETER (IN) LENGTH (IN) 8d 0.131 2 1/2 10d 0.148 3 12d 0.148 3 1/4 16d 0.162 3 1/2 20d 0.192 4 ROOF 1. BLOCKING BETWEEN CEILING JOISTS, RAFTERS OR TRUSSES TO TOP PLATE OR OTHER FRAMING BELOW •EACH END, TOENAIL (4-8D BOX NAILS; OR 3-8D COMMON NAILS; OR 3-10D BOX NAILS; OR 3-3" × 0.131" NAILS) 2. BLOCKING BETWEEN RAFTERS OR TRUSS NOT AT THE WALL TOP PLATE, TO RAFTER OR TRUSS •EACH END, TOENAIL (2-8D COMMON NAILS; OR 2-3" × 0.131" NAILS) •END NAIL (2-16D COMMON NAILS; OR 3-3" × 0.131" NAILS) 3. FLAT BLOCKING TO TRUSS AND WEB FILLER •FACE NAIL (16D COMMON NAILS @ 6" O.C.; OR 3" × 0.131" NAILS @ 6" O.C.) 4. CEILING JOISTS TO TOP PLATE •EACH JOIST, TOENAIL (4-8D BOX NAILS; OR 3-8D COMMON NAILS; OR 3-10D BOX NAILS; OR 3-3" × 0.131" NAILS) 5. RAFTER OR ROOF TRUSS TO TOP PLATE (SEE CBC SECTION 2308.7.5, CBC TABLE 2308.7.5) •2 TOENAILS ON ONE SIDE AND 1 TOENAIL ON OPPOSITE SIDE OF RAFTER OR TRUSSC (3-10 COMMON (3" × 0.148"); OR 3-16D BOX (3 1/2" × 0.135"); OR 4-10D BOX NAILS; OR 4-3" × 0.131 NAILS) 6. ROOF RAFTERS TO RIDGE VALLEY OR HIP RAFTERS; OR ROOF RAFTER TO 2-INCH RIDGE BEAM •END NAIL (2-16D COMMON NAILS; OR 3-16D BOX (3 1/2" × 0.135"); OR 3-10D BOX NAILS; OR 3-3" × 0.131" NAILS) •TOENAIL (3-10D COMMON (3 1/2" × 0.148"); OR 4-16D BOX (3 1/2" × 0.135"); OR 4-10D BOX NAILS; OR 4-3" × 0.131" NAILS) WALL 1. STUD TO STUD (NOT AT BRACED WALL PANELS) •24" O.C. FACE NAIL (16D COMMON NAILS) •FACE NAIL (10D BOX NAILS; OR 3" × 0.131" NAILS) 2. STUD TO STUD AND ABUTTING STUDS AT INTERSECTING WALL CORNERS (AT BRACED WALL PANELS) •16" O.C. FACE NAIL (16D COMMON NAILS) •12" O.C. FACE NAIL (16D BOX NAILS; OR 3" × 0.131" NAILS) 3. BUILT-UP HEADER (2" TO 2" HEADER) •16" O.C. EACH EDGE, FACE NAIL (16D COMMON NAILS) •12" O.C. EACH EDGE, FACE NAIL (16D BOX NAILS) 4. CONTINUOUS HEADER TO STUD •TOENAIL (4-8D COMMON NAILS; OR 4-10D BOX NAILS; OR 5-8D BOX NAILS) 5. TOP PLATE TO TOP PLATE •16" O.C. FACE NAIL (16D COMMON NAILS) •12" O.C. FACE NAIL (10D BOX NAILS; OR 3" × 0.131" NAILS) 6. TOP PLATE TO TOP PLATE, AT END JOINTS •EACH SIDE OF END JOINT, FACE NAIL WITH MINIMUM 24" LAP SPLICE LENGTH EACH SIDE OF END JOINT (8-16D COMMON NAILS; OR 12-16D BOX NAILS; OR 12-10D BOX NAILS; OR 12-3" × 0.131" NAILS) 7. BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING (NOT AT BRACED WALL PANELS) •16" O.C. FACE NAIL (16D COMMON NAILS ) •16" O.C. FACE NAIL (16D BOX NAILS; OR 3" × 0.131" NAILS) 8. BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING AT BRACED WALL PANELS •16" O.C. FACE NAIL (2-16D COMMON NAILS; OR 3-16D BOX NAILS; OR 4-3" × 0.131" NAILS) 9. STUD TO TOP OR BOTTOM PLATE •TOENAIL( 3-16D BOX; OR 4-8D COMMON NAILS; OR 4-10D BOX NAILS; OR 4-3" × 0.131" NAILS; OR 4-8D BOX NAILS) •END NAIL (2-16D COMMON NAILS; OR 3-16D BOX; OR 3-10D BOX NAILS; OR 3-3" × 0.131" NAILS) 10. TOP PLATES, LAPS AT CORNERS AND INTERSECTIONS •FACE NAIL (2-16D COMMON NAILS; OR 3-10D BOX NAILS; OR 3-3" × 0.131" NAILS) FLOOR 1. JOIST TO SILL, TOP PLATE, OR GIRDER •TOENAIL (4-8D BOX; OR 3-8D COMMON NAILS; OR 3-10D BOX NAILS; OR 3-3" × 0.131" NAILS) 2. RIM JOIST, BAND JOIST, OR BLOCKING TO TOP PLATE, SILL OR OTHER FRAMING BELOW •4" O.C., TOENAIL (8D BOX NAILS) •6" O.C., TOENAIL (8D COMMON NAILS; OR 10D BOX NAILS; OR 3" × 0.131" NAILS) 3. 26. BUILT-UP GIRDERS AND BEAMS, 2" LUMBER LAYERS •32" O.C., FACE NAIL AT TOP AND BOTTOM STAGGERED ON OPPOSITE SIDES (20D COMMON NAILS) •24" O.C. FACE NAIL AT TOP AND BOTTOM STAGGERED ON OPPOSITE SIDES (10D BOX NAILS; OR 3" × 0.131" NAILS) •AT ENDS AND AT EACH SPLICE, FACE NAIL (2-20D COMMON NAILS; OR 3-10D BOX NAILS; OR 3-3" × 0.131" NAILS) 4. LEDGER STRIP SUPPORTING JOISTS OR RAFTERS •EACH JOIST OR RAFTER, FACE NAIL (3-16D COMMON NAILS; OR 4-16D BOX NAILS; OR 4-10D BOX NAILS; OR 4-3" × 0.131" NAILS) 5. JOIST TO BAND JOIST OR RIM JOIST •END NAIL (3-16D COMMON NAILS; OR 4-10D BOX NAILS; OR 4-3" × 0.131" NAILS) 6. BRIDGING OR BLOCKING TO JOIST, RAFTER OR TRUSS •EACH END, TOENAIL (2-8D COMMON NAILS; OR 2-10D BOX NAILS; OR 2-3" × 0.131" NAILS) 1. NO SOILS REPORT AVAILABLE; THEREFORE, MINIMUM VALUES USED PER 2022 CBC. 2. ALLOWABLE VERTICAL BEARING PRESSURE = 1500 PSF ALLOWABLE LATERAL BEARING PRESSURE = 100 PSF PER FT OF DEPTH 3. THE CONTRACTOR SHALL CONFORM TO ALL RECOMMENDATIONS AND CONDITIONS INDICATED IN THE 2022 CBC. A GEOTECHNICAL ENGINEER SHALL OBSERVE ALL FOOTING EXCAVATIONS PRIOR TO PLACING CONCRETE. 4. WHERE THE BUILDING OFFICIAL HAS REASON TO DOUBT THE CLASSIFICATION, STRENGTH OR COMPRESSIBILITY OF THE SOIL OR WHERE A LOAD-BEARING VALUE SUPERIOR TO THAT SPECIFIED IN THIS CODE IS CLAIMED, THE BULIDNG OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A GEOTECHNICAL INVESTIGATION BE CONDUCTED. 5. PRESUMPTIVE LOAD-BEARING VALUES SHALL APPLY TO MATERIALS WITH SIMILAR PHYSICAL CHARACTERISTICS AND DISPOSITIONS.MUD, ORGANIC SILT, ORGANIC CLAYS, PEAT OR UNPREPARED FILL SHALL NOT BE ASSUMED TO HAVE A PRESUMPTIVE LOAD-BEARING CAPACITY UNLESS DATA TO SUBSTANIATE THE USE OF SUCH A VALUE ARE SUBMITTED. 5.1. EXCEPTION: A PRESUMPTIVE LOAD-BEARING CAPACITY SHALL BE PERMITTED TO BE USED WHERE THE BUILDING OFFICIAL DEEMS THE LOAD-BEARING CAPACITY OF MUD, ORGANIC SILT OR UNPREPARED FILL IS ADEQUATE FOR THE SUPPORT OF LIGHTWEIGHT OR TEMPORARY STRUCTURES. 6. THE BOTTOM OF FOUNDATION SHALL BE CLEARED AND COMPACTED TO 90 PERCENT OF THE MAXIMUM DRY DENSITY AT OPTIMUM MOISTURE CONTENT DETERMINED IN ACCORDANCE WITH ASTM D1557. 7. SPREAD FOOTINGS ARE CENTERED UNDER WALLS AND COLUMNS, UNO. 8. FOOTING ELEVATIONS ARE NOTED ON THE PLANS AND DETAILS AND SHALL BE USED FOR BIDDING. IN ANY CASE, FOOTINGS SHALL BEAR ON FIRM UNDISTURBED SOIL OR ENGINEERED FILL, IN ACCORDANCE WITH THE CURRENT BUILDING CODE AND DETAILS SHOWN. 9. CONTRACTOR SHALL PROTECT ALL UTILITY LINES, ETC. ENCOUNTERED DURING EXCAVATION AND BACKFILLING. 10. ALL EXCAVATION SHALL COMPLY WITH APPLICABLE OSHA REQUIREMENTS. 11. PRIOR TO REINFORCEMENT FOR FOUNDATIONS BEING PLACED, THE CONTRACTOR SHALL SUBMIT A REPORT INDICATES THE ITEMS 5, 6, 7, 8, 9 AND 10 ARE VERIFIED. THE REPORT SHALL ALSO STATE THAT: 11.1. THE BUILDING PAD WAS PREPARED IN ACCORDANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS. 11.2. THE UTILITY TRENCHES HAVE BEEN PROPERLY BACKFILLED AND COMPACTED. 11.3. THE FOUNDATION EXCAVATIONS COMPLY WITH THE INTENT OF THE APPROVED CONSTRUCTION DOCUMENTS. PROJECT NUMBER: A P R O J E C T F O R : CHECKED: DRAWN: ISSUE/REVISION: 7/ 1 2 / 2 0 1 9 4 : 0 6 : 5 5 P M C : \ U s e r s \ y m i n \ D o c u m e n t s \ S - T h o m p so n _ R 1 7 _ Y m i n . r v t LT201801 S- 2 . 1 2 / 2 7 / 2 0 1 9 Th o m p s o n R e s i d e n c e CITY SUBMITTAL 23 4 4 N . F a i r m o n t Av e n u e , S a n t a A n a , C A , 9 2 7 0 6 E N G I N E E R S I N C 2401 E Katella Ave. #430 Anaheim, CA 92806 Tel. 949.679.0870 Fax. 949.679.9370 Project No.: F482 V C A C I V I LQuality Service Commitment S T R U C T U R A L DBEMBE SBE 02-S001 05/06/2026 Revision 23 3 3 NTS DETAIL10 NTS DETAIL6 NTS DETAIL2 NTS NEW CONC WALL TO (E) CONC WALL14 NTS BUILT UP WOOD STEP9 NTS DETAIL5 NTS DETAIL1 NTS DETAIL13 NTS DETAIL11 NTS DETAIL7 NTS DETAIL3 NTS NEW FOOTING TO (E) FOOTING15 NTS DETAIL8 NTS CHIMNEY INFILL16 SHEAR WALL PER PLAN 3" C L R TY P 2X6 STUDS @16"O/C SIZE & SPACING OF DOWEL TO MATCH SLAB REINF. ± 3" E.N. 2X MIN PTDF SILL PL. W/ S.B. PER SCHED (2) #3 SLAB PER PLAN 18" #3 TIES @24"O/C (2) #5 T&B 6"± ADD ADDT'L #5 @ 12" O/C (3 MIN) W/ STD HOOKS @ FTG EXTENSION 24 " M I N (E) CONC BASEMENT WALL (E) STEPS DOWN TO BASEMENT (N) SLAB ON GRADE PER PLAN 3" C L R TY P SIZE & SPACING OF DOWEL TO MATCH SLAB REINF. SLAB PER PLAN WIDTH PER PLAN #3 TIES @24"O/C (2) #5 T&B 6"± de MI N . HOLDOWN PER PLAN SILL PLATE POST PER SCHEDULE ANCHOR BOLTS PER SCHEDULE EN EQ EQ "F" MIN PAB ANCHOR BOLT SCHEDULE 5/8" DIAMETER 1 3/8" PLATE WASHER SIZE 1/2"X 1 3/4"X 1 3/4" L1 L 1 PLATE WASHER HOLDOWN SCHEDULE HDU2 SIZE SIMPSON PAB PAB4 - 1/2"6" "de" (U.N.O)F 9" (FROM TOP OF PLATE WASHER TO END OF ANCHOR ROD) SHEAR WALL PER PLAN 3"CL R TY P 24 " M I N "F" MIN 6" ± ADD ADDT'L #5 @ 12" O/C T&B (3 MIN)W/ STD HOOKS @ FTG EXTENSION MIN FTG WIDTH PER PLANEXTEND TO MEET "F" MIN ±6" MAX EXTEND TO MEET F MIN PER HOLDOWN SCHEDULE FTG PER PLAN FOR INFORMATION NOT SHOWN HERE SEE 1 - PLAN VIEW HOLDOWN ANCHOR BOLT POST SIZE (2) 2X6 EXTEND TO MEET F MIN PER HOLDOWN SCHEDULE WALL BEYOND SEE ARCHT'L / DRAWINGS EXTERIOR PAVEMENT PER ARCHT'L / CIVIL DRAWINGS 24 " M I N NOT SHOWN ON FDN PLAN 18" MIN V.I.F. (E) FTG (N)CONC SLAB (E) RAISED FLOOR & STEM WALL E.N. A35 @EA SIDE OF POST (N) POST @ (E) WALL (E) SHT'G V.I.F. NOTIFY SEOR ONCE FINISHES REMOVED S.N. B.N. SHEAR WALL PER PLAN E.N. SLAB PER PLAN 2X6 STUDS @16"O/C 24" MIN LAP SPLICE 4" EMBED W/ SIMPSON "SET-3G" EXPOXY ICC #ESR-4057 #3 DOWELS @ MATCH CONC SALB REINF. SPACING 18 " M A X BALANCE OF INFO PER 1 - 18 " M I N "SET-3G" EXPOXY ICC #ESR-4057 6" EMBED W/ SIMPSON ALL FRM'G TO BE PTDF #4 @ 12" O/C SEE ARCHT'L 3" CLR EQ BUILT UP WOOD STEPS PER PLAN 2X MIN PTDF SILL PL. W/ S.B. PER SCHED SIZE & SPACING OF DOWEL TO MATCH SLAB REINF. 12 " SHEAR WALL PER PLAN (2) 2X4 @ 16" O/C BUILT UP WOOD PER PLAN STEPS SLAB ON GRADE PER PLAN 1/2" Ø HEAVY HEX. HED A.B. @ E.A. RCKW 6" EMBED 12" 2x PTDF SILL SIMPSON RCKW3 W/ (4) SD SCREWS TO EA STUD 2" DIA WROUGHT IRON POST @ 4'-0" O.C. (E) WOOD FRAMING (V.I.F.) (E) FTG 3X6 PTDF W/ (2) 1/4" SDD X 5" LONG @24"O/C 2X6 @16"O/C W/ HU HANGERS @ EA END 10d @6"O/C 3x SHAPED 10d @6"O/C SLAB ON GRADE PER PLAN A35 @ EA SHAPED 3x 3/4" PLY TYP @ RISER MIN 2X10 P.T. SILL W/1/2" DIA HILTI KB-TZ-2 EXP ANCHORS W/ 3"NOM EMBED @12"O/C PER ICC ESR 4266 (2) 10d TO EA STRINGER 15" MIN V.I.F. NEW FOOTING TO MATCH EXISTING VERIFY IN FIELD EXISTING DIMENSIONS W/ (2) #5 CONT. AT BOTTOM AND #5@12" O.C. TRANSVERSE (E) RAISED FLOOR FRAMING BEYOND 10d @ 6" O.C. (N) 2X STUDS @ 16" O.C. TO MATCH EXISTING STUDS (E) ROOF FRAMING BEYOND (E) DBL. TOP PLATES SHT'G PER PLAN PROVIDE NEW 1/2" STRUCT-1 PLYWOOD SHEATHING TO MATCH EXISTING W /10d @ 6", 12" PROVIDE NEW 2X CONT. BETWEEN (E) JOISTS THAT HEADED OUT THE (E) CHIMNEY 2X PTDF SILL PL W/ 5/8" DIA. A.B (7" EMBED) @ 16" O.C., (2) A.B. MIN PER SILL PL 10d @ 6" O.C. 12 " M I N V. I . F . STEM WALL TO MATCH EXISTING PROVIDE #4 VERT W/ STD HOOK @ 12 " O.C. AND #4 CONT. HORIZ. @ 12" O.C. FOOTING LONG. REINF. PER PLAN TYP. (E) FOOTING DOWELS TO MATCH FOOTING LONG. REINF. WHERE NEW FOOTING IS DEEPER THAN THE EXISTING FOOTING, PROVIDE 1V:2H BEND IN DOWEL 24" MIN LAP SPLICE 3" TY P . 4" EMBED W/ SIMPSON SET-3G EPOXY PER ICC ESR 4057 (LOCATE EXISTING REINF. BY NON-DESTRUCTIVE MEANS, DO NOT CUT EXISTING REINF.) WALL HORIZ. REINF. PER PLAN TYP. (E) CONC WALL DOWELS TO MATCH WALL HORIZ. REINF. 24" MIN LAP SPLICE EQ . 4" EMBED W/ SIMPSON SET-3G EPOXY PER ICC ESR 4057 (LOCATE EXISTING REINF. BY NON-DESTRUCTIVE MEANS, DO NOT CUT EXISTING REINF.) EQ . #5 STD HOOK DOWEL @ 12" O.C. #4 (30" LONG) TO MATCH SLAB REINF SPACING 3" EMBED W/ SIMPSON SET-3G PER ICC ESR 4057 HOLDOWN PER PLAN SILL PLATE 4X POST @ HOLDOWN EN EQ EQ SHEAR WALL PER PLAN 12 " E M B E D (E) FTG AND STEM WALL (N) SOLID BLK'G @ HOLDOWN POST SIMPSON URFP @ 48" O.C. (N) A35 SIMPSON SET 3G EPOXY PER ICC ESR-4057 SHAPED 2x STAIR STRINGER @ 12" O/C 6" EM B E D PROJECT NUMBER: A P R O J E C T F O R : CHECKED: DRAWN: ISSUE/REVISION: 7/ 1 2 / 2 0 1 9 4 : 0 6 : 5 5 P M C: \ U s e r s \ y m i n \ D o c u m e n t s \ S - T h o m p s o n _ R 1 7 _ Y m i n . r v t LT201801 S- 2 . 1 2 / 2 7 / 2 0 1 9 Th o m p s o n R e s i d e n c e Th o m p s o n , L i n d s a y & B o n n i e Alex.N Alex.Q 04/21/2025 CITY SUBMITTAL 23 4 4 N . F a i r m o n t Av e n u e , S a n t a A n a , C A , 9 2 7 0 6 E N G I N E E R S I N C 2401 E Katella Ave. #430 Anaheim, CA 92806 Tel. 949.679.0870 Fax. 949.679.9370 Project No.: F482 V C A C I V I LQuality Service Commitment S T R U C T U R A L DBEMBE SBE TYPICAL DETAILS 02-S301 SEE DET.- 11 RFI 001 RFI 001 ISSUE/REVISION: 05/15/2025 BLDG DEPT RESUBMITTAL1 03/20/2026 Revision 23 3 05/06/2026 Revision 2