Loading...
HomeMy WebLinkAbout1700 E Garry Ave - Plan4/27/2026 #989857 / B, C10 I HEREBY CERTIFY THAT THE WORK PROPOSED TO BE DONE ON THESE PLANS IS IN CONFORMANCE WITH ALL CODES AND ORDINANCES OF THE AHJ OF CITY OF SANTA ANA AND FURTHER, IF OMISSIONS OR ERRORS ARE DISCOVERED, I UNDERSTAND THAT THE WORK PERFORMED WILL BE REQUIRED TO COMPLY WITH THE CODES AND ORDINANCES OF THE AHJ OF CITY OF SANTA ANA PRIOR TO FINAL BUILDING INSPECTION. SIGNATURE DATE STATE LICENSE NO. PROJECT LOCATION: CRYOPORT SANTA ANA PV 15.26KW DC / 13.86KW AC 1700 E GARRY AVENUE SANTA ANA, CA 92705 NO.DATE DESCRIPTION 1 CONTRACTOR RENEWABLE ENERGY PARTNERS INC 198 LEWIS CT CORONA, CA 92882 CSLB #989857 / B, C10 (855) 519-6633 3/24/2026 INITIAL PLAN SET ELECT. A.L. ARCH D (24" X 36") PRINT PAPER SIZE DESCRIPTION: SYSTEM INFO: STATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER E 24451 EXP. 12/31/2026 ELECT RICAL ANDREW E LOPEZ PV 1 COVER PAGE 4/27/2026 1ST REVISION (RACKING)A.L. DRAWING INDEX CRYOPORT SANTA ANA PV 1700 E GARRY AVENUE SANTA ANA, CA 92705 SYSTEM INFORMATION SCOPE OF WORK VICINITY MAP CITY APPROVAL STAMPS LEGAL DESCRIPTION PARCEL MAP ABBREVIATIONS PHOTOVOLTAIC GENERAL NOTES 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 · · · · · · · ” 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 4/27/2026 #989857 / B, C10 I HEREBY CERTIFY THAT THE WORK PROPOSED TO BE DONE ON THESE PLANS IS IN CONFORMANCE WITH ALL CODES AND ORDINANCES OF THE AHJ OF CITY OF SANTA ANA AND FURTHER, IF OMISSIONS OR ERRORS ARE DISCOVERED, I UNDERSTAND THAT THE WORK PERFORMED WILL BE REQUIRED TO COMPLY WITH THE CODES AND ORDINANCES OF THE AHJ OF CITY OF SANTA ANA PRIOR TO FINAL BUILDING INSPECTION. SIGNATURE DATE STATE LICENSE NO. PROJECT LOCATION: CRYOPORT SANTA ANA PV 15.26KW DC / 13.86KW AC 1700 E GARRY AVENUE SANTA ANA, CA 92705 NO.DATE DESCRIPTION 1 CONTRACTOR RENEWABLE ENERGY PARTNERS INC 198 LEWIS CT CORONA, CA 92882 CSLB #989857 / B, C10 (855) 519-6633 3/24/2026 INITIAL PLAN SET ELECT. A.L. ARCH D (24" X 36") PRINT PAPER SIZE DESCRIPTION: SYSTEM INFO: STATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER E 24451 EXP. 12/31/2026 ELECT RICAL ANDREW E LOPEZ PV 2 SITE PLAN 4/27/2026 1ST REVISION (RACKING)A.L. SITE NOTES SCALE: 1" = 30' N S EW 1 A 2 3 SITE PLAN SCALE: 1/8" = 1'-0" ENLARGED ELECTRICAL ROOM A ARRAY INFORMATION ROOF 1 MODULE COUNT 28 MODULE AREA 773.6SQ.FT. ARRAY TILT 5° ARRAY AZIMUTH 180° 6' PERIMETER CLEARANCES PROPERTY LINE PR O P E R T Y L I N E PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E PR O P E R T Y L I N E EXISTING SYSTEM UTILITY SERVICE MAIN METER / SWITCHBOARD POINT OF INTERCONNECTION SCE METER # NEW PV SYSTEM 1 DISCONNECT 1 OF 1 EXISTING ROOF ACCESS HATCH 1 E GARRY AVE 6'-0" - A 4/27/2026 #989857 / B, C10 I HEREBY CERTIFY THAT THE WORK PROPOSED TO BE DONE ON THESE PLANS IS IN CONFORMANCE WITH ALL CODES AND ORDINANCES OF THE AHJ OF CITY OF SANTA ANA AND FURTHER, IF OMISSIONS OR ERRORS ARE DISCOVERED, I UNDERSTAND THAT THE WORK PERFORMED WILL BE REQUIRED TO COMPLY WITH THE CODES AND ORDINANCES OF THE AHJ OF CITY OF SANTA ANA PRIOR TO FINAL BUILDING INSPECTION. SIGNATURE DATE STATE LICENSE NO. PROJECT LOCATION: CRYOPORT SANTA ANA PV 15.26KW DC / 13.86KW AC 1700 E GARRY AVENUE SANTA ANA, CA 92705 NO.DATE DESCRIPTION 1 CONTRACTOR RENEWABLE ENERGY PARTNERS INC 198 LEWIS CT CORONA, CA 92882 CSLB #989857 / B, C10 (855) 519-6633 3/24/2026 INITIAL PLAN SET ELECT. A.L. ARCH D (24" X 36") PRINT PAPER SIZE DESCRIPTION: SYSTEM INFO: STATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER E 24451 EXP. 12/31/2026 ELECT RICAL ANDREW E LOPEZ PV 3 PLOT PLAN 4/27/2026 1ST REVISION (RACKING)A.L. PLAN LEGEND SCALE: 1" = 20' PLOT PLAN SCALE: 1/4" = 1'-0" ELEVATION VIEW B SCALE: 1/8" = 1'-0" ENLARGED ELECTRICAL ROOM C N S EW 40'-0" 3'-0" 6'-0" MIN. 45'-2" 86'-7" 180'-1" 186'-6" 281'-11" 341'-11" 1 2 - C - B 2'-0" TYP. 4/27/2026 #989857 / B, C10 I HEREBY CERTIFY THAT THE WORK PROPOSED TO BE DONE ON THESE PLANS IS IN CONFORMANCE WITH ALL CODES AND ORDINANCES OF THE AHJ OF CITY OF SANTA ANA AND FURTHER, IF OMISSIONS OR ERRORS ARE DISCOVERED, I UNDERSTAND THAT THE WORK PERFORMED WILL BE REQUIRED TO COMPLY WITH THE CODES AND ORDINANCES OF THE AHJ OF CITY OF SANTA ANA PRIOR TO FINAL BUILDING INSPECTION. SIGNATURE DATE STATE LICENSE NO. PROJECT LOCATION: CRYOPORT SANTA ANA PV 15.26KW DC / 13.86KW AC 1700 E GARRY AVENUE SANTA ANA, CA 92705 NO.DATE DESCRIPTION 1 CONTRACTOR RENEWABLE ENERGY PARTNERS INC 198 LEWIS CT CORONA, CA 92882 CSLB #989857 / B, C10 (855) 519-6633 3/24/2026 INITIAL PLAN SET ELECT. A.L. ARCH D (24" X 36") PRINT PAPER SIZE DESCRIPTION: SYSTEM INFO: STATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER E 24451 EXP. 12/31/2026 ELECT RICAL ANDREW E LOPEZ PV 8 RACKING DETAILS 4/27/2026 1ST REVISION (RACKING)A.L. PV MODULE PV MID / END CLAMP IRONRIDGE FLAT ROOF ATTACHMENT IRONRIDGE XR100 (8) #14 Self-Tapping Screws into (E) Metal Deck 71 4 " 4' 1'-31 4 " 5.0° 1'-9" IRONRIDGE NORTH TILT LEG IRONRIDGE SOUTH TILT LEG BUILDING SPECIFICATIONS TYPE: STORIES: BUILDING HEIGHT: SQUARE FOOTAGE: ROOF SLOPE (°): ROOF TYPE: FRAME: MOUNTING SPECIFICATIONS B 2 40'-0" 116,997 <5° TPO 36LH @ 8'-0" O.C. RACKING SYSTEM: ATTACHMENT SPACING: MOUNTING TYPE: TILT LEG HEIGHT: HEIGHT OF PV MODULE ABOVE ROOF SURFACE: IRONRIDGE XR100 5° TILT LEG N/A TILT 5° N/A ~12" 4/27/2026 #989857 / B, C10 I HEREBY CERTIFY THAT THE WORK PROPOSED TO BE DONE ON THESE PLANS IS IN CONFORMANCE WITH ALL CODES AND ORDINANCES OF THE AHJ OF CITY OF SANTA ANA AND FURTHER, IF OMISSIONS OR ERRORS ARE DISCOVERED, I UNDERSTAND THAT THE WORK PERFORMED WILL BE REQUIRED TO COMPLY WITH THE CODES AND ORDINANCES OF THE AHJ OF CITY OF SANTA ANA PRIOR TO FINAL BUILDING INSPECTION. SIGNATURE DATE STATE LICENSE NO. PROJECT LOCATION: CRYOPORT SANTA ANA PV 15.26KW DC / 13.86KW AC 1700 E GARRY AVENUE SANTA ANA, CA 92705 NO.DATE DESCRIPTION 1 CONTRACTOR RENEWABLE ENERGY PARTNERS INC 198 LEWIS CT CORONA, CA 92882 CSLB #989857 / B, C10 (855) 519-6633 3/24/2026 INITIAL PLAN SET ELECT. A.L. ARCH D (24" X 36") PRINT PAPER SIZE DESCRIPTION: SYSTEM INFO: STATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER E 24451 EXP. 12/31/2026 ELECT RICAL ANDREW E LOPEZ PV 9 STRUCTURAL 4/27/2026 1ST REVISION (RACKING)A.L. SCALE:1" = 20' STRUCTURAL FRAMING PLAN 4/27/2026 #989857 / B, C10 I HEREBY CERTIFY THAT THE WORK PROPOSED TO BE DONE ON THESE PLANS IS IN CONFORMANCE WITH ALL CODES AND ORDINANCES OF THE AHJ OF CITY OF SANTA ANA AND FURTHER, IF OMISSIONS OR ERRORS ARE DISCOVERED, I UNDERSTAND THAT THE WORK PERFORMED WILL BE REQUIRED TO COMPLY WITH THE CODES AND ORDINANCES OF THE AHJ OF CITY OF SANTA ANA PRIOR TO FINAL BUILDING INSPECTION. SIGNATURE DATE STATE LICENSE NO. PROJECT LOCATION: CRYOPORT SANTA ANA PV 15.26KW DC / 13.86KW AC 1700 E GARRY AVENUE SANTA ANA, CA 92705 NO.DATE DESCRIPTION 1 CONTRACTOR RENEWABLE ENERGY PARTNERS INC 198 LEWIS CT CORONA, CA 92882 CSLB #989857 / B, C10 (855) 519-6633 3/24/2026 INITIAL PLAN SET ELECT. A.L. ARCH D (24" X 36") PRINT PAPER SIZE DESCRIPTION: SYSTEM INFO: STATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER E 24451 EXP. 12/31/2026 ELECT RICAL ANDREW E LOPEZ PV 10 UL LISTING 4/27/2026 1ST REVISION (RACKING)A.L. NEW EQUIPMENT SCHEDULE #EQUIPMENT MANUFACTURER/MODEL EQUIPMENT DESCRIPTION 1 CANADIAN SOLAR CS6W-545MB-AG CANADIAN SOLAR 545W PV MODULE 2 YOTTA ENERGY DPI-480 YOTTA ENERGY 1800W MICRO-INVERTER 3 JUNCTION BOX NEMA 3R JUNCTION BOX 4 AC DISCONNECT SWITCH 30A, 20A FUSES, 600V, 3Ꝋ, 4W, NEMA 1, VISIBLE KNIFE BLADE SEPARATION WHILE OPEN & LOCKABLE WHILE IN THE OPEN POSITION 112112 112 112 112112 112 GND 4 SQUARE D VH361N OR SIMILAR M TO EXISTING LOADS (E) 2000A SWITCHGEAR 3Ꝋ, 4W, 480Y/277V NEMA 3R, 65KAIC SCE METER EXISTING 2000A 65KAIC TO UTILITY TRANSFORMER (E) EGC TO SWITCHGEAR FRAME/STRUCTURE (E) BONDING JUMPER TO GROUND ROD. GROUND SYSTEM SHALL HAVE RESISTANCE OF 25OHM MAX. (N) 20A 3P (E) BONDING JUMPER NEAREST METAL, WATER PIPE, GAS PIPE, HVAC PER 250.104 (A), (B), & (C). (E) 175A 3P (E) T-2G1A XFMR (E) 400A 2G1A (E) 20A RECPT. FOR PV MONITORING IN NEMA 3R ROOFTOP J-BOX CA 1/2" EMT (2) #10 THWN-2 (1) #10 GROUND 3 B 4/27/2026 #989857 / B, C10 I HEREBY CERTIFY THAT THE WORK PROPOSED TO BE DONE ON THESE PLANS IS IN CONFORMANCE WITH ALL CODES AND ORDINANCES OF THE AHJ OF CITY OF SANTA ANA AND FURTHER, IF OMISSIONS OR ERRORS ARE DISCOVERED, I UNDERSTAND THAT THE WORK PERFORMED WILL BE REQUIRED TO COMPLY WITH THE CODES AND ORDINANCES OF THE AHJ OF CITY OF SANTA ANA PRIOR TO FINAL BUILDING INSPECTION. SIGNATURE DATE STATE LICENSE NO. PROJECT LOCATION: CRYOPORT SANTA ANA PV 15.26KW DC / 13.86KW AC 1700 E GARRY AVENUE SANTA ANA, CA 92705 NO.DATE DESCRIPTION 1 CONTRACTOR RENEWABLE ENERGY PARTNERS INC 198 LEWIS CT CORONA, CA 92882 CSLB #989857 / B, C10 (855) 519-6633 3/24/2026 INITIAL PLAN SET ELECT. A.L. ARCH D (24" X 36") PRINT PAPER SIZE DESCRIPTION: SYSTEM INFO: STATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER E 24451 EXP. 12/31/2026 ELECT RICAL ANDREW E LOPEZ PV 4 SINGLE LINE DIAGRAM 4/27/2026 1ST REVISION (RACKING)A.L. EQUIPMENT NOTES 1 2 3 4 5 6 4/27/2026 #989857 / B, C10 I HEREBY CERTIFY THAT THE WORK PROPOSED TO BE DONE ON THESE PLANS IS IN CONFORMANCE WITH ALL CODES AND ORDINANCES OF THE AHJ OF CITY OF SANTA ANA AND FURTHER, IF OMISSIONS OR ERRORS ARE DISCOVERED, I UNDERSTAND THAT THE WORK PERFORMED WILL BE REQUIRED TO COMPLY WITH THE CODES AND ORDINANCES OF THE AHJ OF CITY OF SANTA ANA PRIOR TO FINAL BUILDING INSPECTION. SIGNATURE DATE STATE LICENSE NO. PROJECT LOCATION: CRYOPORT SANTA ANA PV 15.26KW DC / 13.86KW AC 1700 E GARRY AVENUE SANTA ANA, CA 92705 NO.DATE DESCRIPTION 1 CONTRACTOR RENEWABLE ENERGY PARTNERS INC 198 LEWIS CT CORONA, CA 92882 CSLB #989857 / B, C10 (855) 519-6633 3/24/2026 INITIAL PLAN SET ELECT. A.L. ARCH D (24" X 36") PRINT PAPER SIZE DESCRIPTION: SYSTEM INFO: STATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER E 24451 EXP. 12/31/2026 ELECT RICAL ANDREW E LOPEZ PV 5 GROUNDING 4/27/2026 1ST REVISION (RACKING)A.L. RAIL TO RAIL BONDING #6 BARE COPPER WIRE INVERTER (IF USED)MSP CONTINUOUS GROUND PER SLD JBOX GROUND BUSHINGS MODULE RAIL SOLAR METER (IF REQ) (A) (1) BOND STRIP GROUNDS RAIL TO RAIL SPLICES - STAR WASHERS USED TO BOND RAIL TO BONDING STRIP (2) SPLICE BAR, SELF-TAP SCREWS JOIN RAILS. BONDING STRIPS USED ON RAILS WITH GROUND LUGS. (1)(2) (3) IF SPLICE BAR HAS INTEGRATED GROUND, BONDING STRIP IS NOT NECESSARY. (3) WHERE NEITHER BONDING STRIP, INTEGRATED GROUNDING SPLICE BAR, OR INTEGRATED GROUNDING MIDCLAMP ARE USED, UL 2703 APPROVED GROUND LUG WITH #6 BARE COPPER SHALL BE USED TO GROUND SPLICED RAILS. USE METHOD (2) (1) (C) RAIL SPLICE GROUNDING (C) #6 BARE COPPER RAIL 1 RAIL 2 EITHER METHOD 1-3 PER MANUFACTURERS INSTALL INSTRUCTIONS CONDUIT GROUNDING BUSHING WHERE REQUIRED ENCLOSURE CONTINUOUS GROUND STRIP INSULATION CONDUIT GROUNDING DETAIL EQUIPMENT GROUND BUSHINGS REQ. FOR SYSTEMS OVER 250V (A) GROUNDING MID CLAMP EACH GROUNDING MID CLAMP PIERCES THROUGH THE ANODIZED COATINGS OF BOTH THE MODULE FRAME AND THE MOUNTING RAIL TO FORM SECURE ELECTRICAL BONDS, WHICH ARE REPEATED THROUGHOUT THE ARRAY. MIDCLAMP TEETH MODULE PENETRATION SERRATED T-BOLT BONDS CLAMP TO RAIL COMPRESSION FITTING LOCK NUT WHERE REQUIRED 4/27/2026 #989857 / B, C10 I HEREBY CERTIFY THAT THE WORK PROPOSED TO BE DONE ON THESE PLANS IS IN CONFORMANCE WITH ALL CODES AND ORDINANCES OF THE AHJ OF CITY OF SANTA ANA AND FURTHER, IF OMISSIONS OR ERRORS ARE DISCOVERED, I UNDERSTAND THAT THE WORK PERFORMED WILL BE REQUIRED TO COMPLY WITH THE CODES AND ORDINANCES OF THE AHJ OF CITY OF SANTA ANA PRIOR TO FINAL BUILDING INSPECTION. SIGNATURE DATE STATE LICENSE NO. PROJECT LOCATION: CRYOPORT SANTA ANA PV 15.26KW DC / 13.86KW AC 1700 E GARRY AVENUE SANTA ANA, CA 92705 NO.DATE DESCRIPTION 1 CONTRACTOR RENEWABLE ENERGY PARTNERS INC 198 LEWIS CT CORONA, CA 92882 CSLB #989857 / B, C10 (855) 519-6633 3/24/2026 INITIAL PLAN SET ELECT. A.L. ARCH D (24" X 36") PRINT PAPER SIZE DESCRIPTION: SYSTEM INFO: STATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER E 24451 EXP. 12/31/2026 ELECT RICAL ANDREW E LOPEZ PV 6 SIGNAGE 4/27/2026 1ST REVISION (RACKING)A.L. SIGNAGE REQUIREMENTS GENERAL FIRE GUIDELINES & MARKING REQTS: SEC. 5. MARKINGS, LABELS, AND WARNING SIGNS. CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED CAUTION: SOLAR CIRCUIT COMBINER BOX/ CIRCUITS/ CONDUIT/ COMBINER BOX/ ENCLOSURES/ EMT ENCLOSURES1 1 WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL 1 2 BUILDING / STRUCTURE2 CEC 705.10 - BY MAIN SERVICE PANEL: CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN. 1700 E GARRY AVENUE SANTA ANA, CA 92705 WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION MAIN ELECTRIC SERVICE DISCONNECT SOLAR A/C DISCONNECT PV SOLAR ARRAY(S) EMT/ DC CONDUIT RACEWAYS4 WARNING: PHOTOVOLTAIC POWER SOURCE PRODUCTION/ NET METER6 WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM AC DISCONNECT/ BREAKER/ POINTS OF CONNECTION7 PHOTOVOLTAIC AC DISCONNECT WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION BREAKER PANEL/ PULL BOXES8 WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL MAIN SERVICE DISCONNECT9 WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SOLAR ELECTRIC PV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN (690.56(C)(1)(a) YELLOW WITH BLACK LETTERING) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 10 BY RAPID SHUTDOWN SWITCH (WITHIN 3 FT)10 10 7 4 3 5 8 6 9 PV SYSTEM LABELING REQUIREMENTS NOT TO SCALE AC PHOTOVOLTAIC DISCONNECT OUTPUT CURRENT: OPERATING VOLTAGE: 1 AC PHOTOVOLTAIC DISCONNECT OUTPUT CURRENT: OPERATING VOLTAGE: 5 7 4 4 *RAPID SHUTDOWN SWITCH CAN BE EITHER THE AC DISCONNECT SWITCH OR A SEPARATE SWITCH. SEE PV 4 FOR TYPE OF RS SWITCH ARC FLASH AND SHOCK HAZARD APPROPRIATE PPE AND TOOLS REQUIRED WHILE WORKING ON THIS ENERGIZED EQUIPMENT. WARNING WARNING POWER SOURCE OUTPUT CONNECTION - DO NOT RELOCATE THIS OVERCURRENT DEVICE CEC 705.12(B)(2)(3)(b) CEC 690.13(B) CEC 690.13(B) CEC 690.13(B) CEC 690.31(G)(3) CEC 690.13(B) CEC 690.54 CEC 110.16 CEC 690.59, 705.12(D)(3) CEC 110.27(C) CEC 690.13(B) CEC 690.27(C) CEC 690.13(B) CEC 690.27(C) CEC 690.13(F), 705.12(B)(3-4) CEC 690.59, 705.12(B)(3-4) WARNING POWER SOURCE OUTPUT CONNECTION - DO NOT RELOCATE THIS OVERCURRENT DEVICE CEC 705.12(B)(2)(3)(b) 15A SOLAR DISCONNECT 15A N S E W 208V 208V 4/27/2026 #989857 / B, C10 I HEREBY CERTIFY THAT THE WORK PROPOSED TO BE DONE ON THESE PLANS IS IN CONFORMANCE WITH ALL CODES AND ORDINANCES OF THE AHJ OF CITY OF SANTA ANA AND FURTHER, IF OMISSIONS OR ERRORS ARE DISCOVERED, I UNDERSTAND THAT THE WORK PERFORMED WILL BE REQUIRED TO COMPLY WITH THE CODES AND ORDINANCES OF THE AHJ OF CITY OF SANTA ANA PRIOR TO FINAL BUILDING INSPECTION. SIGNATURE DATE STATE LICENSE NO. PROJECT LOCATION: CRYOPORT SANTA ANA PV 15.26KW DC / 13.86KW AC 1700 E GARRY AVENUE SANTA ANA, CA 92705 NO.DATE DESCRIPTION 1 CONTRACTOR RENEWABLE ENERGY PARTNERS INC 198 LEWIS CT CORONA, CA 92882 CSLB #989857 / B, C10 (855) 519-6633 3/24/2026 INITIAL PLAN SET ELECT. A.L. ARCH D (24" X 36") PRINT PAPER SIZE DESCRIPTION: SYSTEM INFO: STATE OF CALIFORNIA REGISTERED PROFESSIONAL ENGINEER E 24451 EXP. 12/31/2026 ELECT RICAL ANDREW E LOPEZ PV 7 EQUIPMENT SPECIFICATIONS 4/27/2026 1ST REVISION (RACKING)A.L. YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs V I N C I & A S S O C I A T E S Structural Engineers STRUCTURAL CALCULATIONS FOR PHOTOVOLTAIC Santa Ana, CA CLIENT: Renewable Energy Partners 805.496.2100 • VinciSE.com 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ARRAY JOB NO: 22-3457 Cryoport Santa Ana 1700 E Garry Ave DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Cryoport Santa Ana Structural Engineers JOB NO.:22-3457 1700 E Garry Ave 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Renewable Energy Partners DESIGN DATA: ROOF DESIGN LOAD: ROOFING ( Standing Seam )=3 psf SHEATHING =2 ROOF RAFTERS / TRUSS =2 MISCELLANEOUS =1 ROOF RAFTER/TRUSS DESIGN DEAD LOAD =8.0 psf CEILING & INSULATION =0 MISCELLANEOUS =1.25 DESIGN DEAD LOAD =9.3 psf DESIGN LIVE LOAD =20 psf DESIGN SNOW LOAD =0 psf WIND DESIGN CRITERIA: BASIC WIND SPEED =100 mph WIND EXPOSURE =C NUMBER OF STORIES =1 ROOF SLOPE =0° IMPORTANCE FACTOR =1 SOLAR MODULE Solar Module Width:=44.65 in Solar Module Length:=89.21 in Solar Module Area =27.66 ft2 Solar Module Dead Load =3 psf Number of PV Modules =28 Maximum Spacing of Mounts =8 ft o.c. Tributary Area to Mounts ( 8 ft oc x 89.21 in / 12''/ft ) / 2 =29.74 ft2 PV Array Point Load (DL) 29.74 ft2 x 3.00 psf =89.2 lbs TOTAL AREA OF ADDED SOLAR PANELS (3.72 ft x 7.43 ft ) x (28 Modules ) =774.5 ft2 4/28/2026 - 1 DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Cryoport Santa Ana Structural Engineers JOB NO.:19-3457 1700 E Garry Ave 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Renewable Energy Partners DESIGN CONNECTION TO ROOF TO RESIST WIND UPLIFT REFER TO NEXT SHEET FOR UPLIFT FORCE CALCULATIONS UPLIFT =- 3.00 psf Design Force = ( Uplift x (0.6) ) - 3.00 psf ADD Net Uplift = CONNECTION DETAIL HERE Max Trib Area =ft2 UPLIFT / CONN. =29.7 ft2 x 25.0 psf =lbs/conn PALLOW = 864 lbs FOS:3 for (6) 1/4" self-tapping screws into mtl deck PALLOW = 6 x 288 lbs = 1728.0 lbs >743 lbs Therefore O.K. 743.5 4/28/2026 - 46.7 psf 25.0 psf 29.74 2 DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Cryoport Santa Ana Structural Engineers JOB NO.: 1700 E Garry Ave 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:22-3457 Santa Ana, CA 805.496.2100 • VinciSE.com Company Renewable Energy Partners Wind Analysis Per ASCE 7-22 - Components and Cladding Roof Top Solar Panels - FLAT ROOF (psf)(ASCE 7 29.4.3) Exposure Category :C Lp (length of panel) :6.67 ft Importance Factor :1 Angle of Array (ω) :5° Basic Wind Speed :100 Array Edge Location : Topographical factor :1 Flat North :4.0 ft Bldg Ht to eave (H 1 ) :20 ft South :4.0 ft Ht of Parapet (H P ) :3 ft East :4.0 ft Bldg L :342 ft West :4.0 ft Bldg W :282 ft Effective area :29.74 ft2 qh =23.04 psf (q h = 0.00256K z K zt K e V 2 )(ASCE 7, 26.10) GCrn =(Ƴp) (Ƴc) (ƳΕ) (GCrn) nom (ASCE 7, 29.4-7) p =qh Kd (GCrn )(ASCE 7, 29.4-5) Zone 1 Zone 2 Zone 3 (GCrn) nom =0.96 1.33 1.51 (ASCE 7, Figure 29.4-7) WindUp Zone Ƴ P Ƴ c Ƴ E K d P (psf)USE:46.67 psf North Edge:3 1.05 1.00 1.5 0.85 46.7 South Edge:3 1.05 1.00 1.5 0.85 46.7 East Edge:3 1.05 1.00 1.5 0.85 46.7 West Edge:3 1.05 1.00 1.5 0.85 46.7 WindDown Zone Ƴ P Ƴ c Ƴ E K d P (psf)USE:31.11 psf North Edge:3 1.05 1.00 1 0.85 31.1 South Edge:3 1.05 1.00 1 0.85 31.1 East Edge:3 1.05 1.00 1 0.85 31.1 West Edge:3 1.05 1.00 1 0.85 31.11.51 4/28/2026 (GCrn) nom 1.51 1.51 1.51 1.51 (GCrn) nom 1.51 1.51 1.51 3 DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Cryoport Santa Ana Structural Engineers JOB NO.:22-3457 1700 E Garry Ave 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Renewable Energy Partners LATERAL FORCES: (Base Shear Calculations -2025 CBC /ASCE-22 ) SEISMIC: Site Class:D (Use D if unknown) S1=0.480 (USGS Software)SS=1.45 (USGS Software) I =1.0 (Sec 11.5-1 ASCE 7-22) R =5.0 (Table 12.2-1 ASCE 7-22) SMS =1.72 (USGS Software)SDS = (Eq. 11.4-1) SM1=1.16 (USGS Software)SD1 = (Eq. 11.4.2) T0 = s Cu =1.4 (Table 12.8-1 ASCE 7-22) TS = s Ct =0.02 (Table 12.8-2 ASCE 7-22) TL = 8 s x =0.75 (Table 12.8-2 ASCE 7-22) T = Ct * (hn)x =(Eq. 12.8-7)Cv =1.5 (Table 11.9-1 ASCE 7-22) hn =22.0 ft Sa =SD1 / TL = V =CS W (Eq. 12.8-1 ASCE 7-22) * *GOVERNS * * CS = ( SDS) / ( R / I ) =0.23 W (Eq. 12.8-3 ASCE 7-22) NEED NOT EXCEED: IF T ≤ TL USE: CS = ( SD1) / T *( R / I ) =(Eq. 12.8-4 ASCE 7-22) IF T > TL USE: CS = ( SD1)*(TL) / T² *( R / I ) =(Eq. 12.8-5 ASCE 7-22) SHALL NOT BE LESS THAN: CS = 0.044SDS I =0.05 >(Eq. 12.8-6 ASCE 7-22) WHERE S1 > 0.6, CS MIN SHALL BE: CS = 0.5S1 / ( R/I ) =0.048 (Eq. 12.8-7 ASCE 7-22) 4/28/2026 ²/3 * SMS = ²/3 * SM1 = ( SD1 / SDS ) 0.203 s 0.01 W = 0.674 0.2( SD1 / SDS )= 0.135 1.15 0.77 0.10 0.76 W 0.76 W 4       !""# $% &!! !% ' ()*% +&-.0 1123444% 524*3364)899:;< =>88>=8 ?@ BC" 7 "#EEGHIJ7A"-L- N7!!OQR @ S TUJV VT UUVJ J : UW HV J  X <  IJ H YQR @ S TUJV VT UUVJ J = UW HV J  X <  IJ H Y @ [ =P \ G < JR S]QVYJW @\^I^ WVW VJR_I] `@ Sa TUJV VT UUVJ HV RVJ TVW `H JR JTUJVI^a W JR IVTUHW J  @= [ =P \ G=< JR @ S TUJV VT UUVJ HV = UW `H JR JTVW TUJVI^a W JR IVTUHW J QR WY TUJV VT UUVJ HV RVJ TVW `H JR JTVW TUJVI^a W JR IVTUHW J <  IJ H YQR WY TUJV VT UUVJ HV = UW `H JR JTVW TUJVI^a W JR IVTUHW J <  IJ H Y 7A"-L- N7!! '.2O ^U WY UJYVbP?c @< JR c^JVU@ @\^I^ WVW VJR_I] `@ ca T] YVIW UUVJ HV JR IVTUHW J <  Id Q [ G=9 G <  UW< HV UJVIUJ H JR JTVW WY TUJVI^dP Q: [ : \ Q <  UW< HV UJVIUJ H JR JTVW WY VT TUJVI^Qe< JR YTVW JVJ TVW<  UW< HV UJVIUJ H JR JTVW WY VT TUJVI^ 5 DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Cryoport Santa Ana Structural Engineers JOB NO.:22-3457 1700 E Garry Ave 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Renewable Energy Partners LATERAL FORCES:(BASE SHEAR - Conservative) 2025 CBC F1 SEISMIC BASE SHEAR: V =0.23 W (SEE PREVIOUS)h1 =20.0 ft F1 ROOF =9 PSF WALLS =10 19.0 x 0.229 4.35 PSF WIND LOADS: Governs ps = λ kzt Iw ps30 (Eq. 6-1) λ =1.21 ps30A =psf psA psf Iw = 1.00 ps30B =psf psB psf kzt = 1.00 ps30C =psf psC psf ps30D =psf psD psf F1ULT:= ( 2 ft + 20 ft /2 ) x (23.2704 psf +12.12 psf ) =425 lb/ft F1ASD:=lb/ft x 0.6 =255 lb/ft424.68 2.0 ft 23.27 -12.12 15.39 -7.15 19.20 -10.00 12.70 -5.90 4/28/2026 hROOF= - 6 DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Cryoport Santa Ana Structural Engineers JOB NO.:22-3457 1700 E Garry Ave 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Renewable Energy Partners CHECK IMPACT OF NEW SOLAR PANELS ON SEISMIC LOAD ADD ROOF PLAN HERE TOTAL ROOF AREA: (342.0 ft x 282 ft ) + (0.0 ft x 0.0 ft ) + (0.0 ft x 0.0 ft ) + (0.0 ft x 0.0 ft ) = EXISTING ESTIMATED SEISMIC LOAD (BASE SHEAR) 96444 ft2 x 4.35 psf =419246 lbs AREA OF ADDED SOLAR PANELS (PER PAGE 1)=ft2 WEIGHT OF PANELS:3 psf ADDED SEISMIC LOAD: 3 psf x ft2 x 0.23 =532.9 lbs Therefore O.K. Per CEBC SECTION 502.5 774.5 774.5 =0.1%<10%% INCREASE =532.9 419245.872 4/28/2026 - 96444 ft2 7 DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Cryoport Santa Ana Structural Engineers JOB NO.:22-3457 1700 E Garry Ave 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Renewable Energy Partners CHECK IMPACT OF NEW SOLAR PANELS ON GRAVITY LOAD ADD ROOF PLAN HERE TOTAL ROOF AREA: (342.0 ft x 282 ft ) + (0.0 ft x 0.0 ft ) + (0.0 ft x 0.0 ft ) + (0.0 ft x 0.0 ft ) = EXISTING ESTIMATED GRAVITY LOAD 96444 ft2 x 9.25 psf =892107 lbs AREA OF ADDED SOLAR PANELS (PER PAGE 1)=ft2 WEIGHT OF PANELS:3 psf ADDED GRAVITY LOAD: 3 psf x ft2 x 1 =2323.5 lbs Therefore O.K. 774.5 774.5 % INCREASE =2323.5 =0.3%<5% 892107 4/28/2026 - 96444 ft2 8 DATE:V I N C I & A S S O C I A T E S SHEET: PROJECT:Cryoport Santa Ana Structural Engineers JOB NO.:22-3457 1700 E Garry Ave 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Renewable Energy Partners CHECK OF EXISTING ROOF STRUCTURE Existing Roof Dead Load 9.25 psf Existing Roof Live Load:20 psf reducable PV Array Dead Load 3 psf Per 2025 California Building Code Section 1607.12.1.1 when a PV array is installed less than 24" above the surface of the roof surface, the live load can be ignored below the PV array. Therefore - if the 20 psf (12psf min when reduced) is eliminated below the proposed PV Arrays, the roof is more than capable of supporting the additional 3.00 psf dead load due to the proposed array. Therefore, by observation, the existing roof structure is sufficient. CHECK EXISTING PURLIN 36LH Spacing:8 ft oc Existing Roof Dead Load:74 plf Existing Roof Live Load:160 plf PV Array Load:24 plf ACTUAL LOAD:258 plf ALLOWABLE LOAD 274 plf THEREFORE O.K. 4/28/2026 9