Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
10141615.pdf
I 'I pia %3"[)LjLjI"UIC Em I I I I son J16 Prospect Ave ermosa Beach ;alifornia 90254 Mao Cc rw' N �a o ,c I*Wm.� cc CL cA 0. o z,= vj cc cu co c ►r% c m • ITI a 10 [l[lCll M ANT©TI [� fILLIS DANItLS MUE DATE: Pntemher 11. 200 VALC: of to Scale a imu PAGE 1 OF SHEET I NIDEX GENERAL NOTES FIRE PREVENTION NOTES WILLIS lA COVER SWEET 2.0 NOTES AND INFORMATION 3.0 PATH OF TRAVEL AND iZEBTROOM ACCESSIBILITY PLAN 4.0 CONSTRUCTION PLAN 5.0 TELEPHONE /ELECTRICAL PLAN 6.0 REFLECTED CEILING PLAN 1.0 FINISH PLAN 8A INTERIOR ELEVATIONS AND DETAILS 9A DETAILS Y I G IN I TY MAF TENANT SPACE FIRST FLOOR SUITE #1048 5U I L D ING I NFORMAT ION 1. THE CONTRACTOR SHALL CONFORM TO ALL CODES, ORDINANCES, ETC. WHICH HAVE JURISDICTION OVER THE WOFW, THE CONTRACTOR SHALL RETAIN RESPONS151LITY FOR COMPLIANCE WITH THE LATEST REVISIONS OF- ALL OTHER APPLICABLE CODES AND ORDINANCES - INCLUDING THE FOLLOWING: 2. BUILDING CODE: SITE ADDRESS: 3. OCCUPANCY CLASSIFICATION: CONSTRUCTION TYPE: 4. USABLE SO. FT.: 5. BUILDING CODE: IeS4 UNIFORM BUILDING CODE 2800 N. MAIN STREET SUITE kJO40 SANTA ANA, CA S2105 1 ST FLOOR 5 TYPE I - FR CONSTRUCTION, FULLY SPRINKLED 1,339 SQ. FT. CONSTRUCTION AREA ISS4 UNIFORM BUILDING CODE, UPC, UMC AND NEC WITH STATE AND LOCAL AMENDMENTS. CLIENT: NAME: ADDRESS: CRESENT MARKETING INC. 5-18 S. STATE COLLEGE 5OULEVARD FULLERTON, CA °32831-5114 TELEPHONE: '14.5'12 W22 X 204 CELL: 114.1913028 CONTACT: KEVIN 5AQA1 CONSTRUCTION / BUILDING MANAGEMEN NAME: WESTFIELD AMERICA INC. ADDRESS: 11601 WILSHIRE BLVD. 12TW FLOOR LOS ANGELES, CA SOO25 TELEPHONE: 310. 418.4456 FAX: CONTACT: T.A. JONES SPAC NAME: WILLIS DANIELS DESIGN ADDRESS: 1016 PROSPECT AVENUE HERMOSA BEACH, CA W254 TELEPHONE: 3103193138 FAX: 310312.8101 CONTACT: WILLIS DANIELS GENERAL CONTRACTOR NAME: TO BE DETERMINED ADDRESS: TELEPHONE: FAX: CONTACT: TELEPHONE: FAX: CONTACT: NAME:ELECTRICAL ENGINEER BY: DESIGN ASSIST CONTRAC r r ADDRESS: TELEPHONE: FAX: CONTACT: SANTA ANA CITY NOTES SPECIAL REQUIREMENTS FOR MAIN PLACE: MALL. FIRE SPRINKLER SYSTEM: ALL C-CLAMPS (50TH NEW AND EXISTING) USED TO HANG FIRE SPRINKLER LINES MUST HAVE EARTHQUAKE RETAINING STRAPS INSTALLED,, EVERY SUITE IN THE MALL MUST HAVE IT'S OWN SPARE SPRINKLER HEAD SOX WITH SPARE HEADS AND THE CORRECT TOOLS REQUIRED TO CHANGE OUT SPRINKLER MEADS. NO SPRINKLER SYSTEM PIPING, HANGERS, OR SWAY BRACING MAY BE COVERED UNTIL A ROUGH INSPECTION IS COMPLETED AND SIGNED FOR BY THE SANTA ANA FIRE DEPARTMENT. SMOKE DETECTION AND REMOVAL SYSTEM: EVERY SUITE IS REQUIRED TO HAVE ONE SMOKE DETECTOR THAT IS PART OF THE MALLS SMOKE REMOVAL SYSTEM, INSTALLED WITHIN TEN (10) FEET OF THE MAIN SUITE ENTRANCE. ALL NEW WIRING FOR THE SMOKE REMOVAL SYSTEM MUST BE SIGNED FOR BY A CITY OF SANTA ANA ELECTRICAL INSPECTOR. PRETEST THE SMOKE REMOVAL SYSTEM TO ASSURE THAT 50TH THE INTERIOR AND EXTERIOR SMOKE REMOVAL FANS OPERATE PRIOR TO CALLING FOR FIRE INSPECTION. ANY CHANGES TO THE SMOKE REMOVAL SYSTEM DUCTI WILL REQUIRE APPROVAL FROM A CITY OF SANTA ANA HVAC INSPECTOR. ROLL UP SECURITY GRILLS: ALL ELECTRICALLY OPERATED STOREFRONT GRILLS MUST BE EQUIPPED WITH A -- MANUAL EMERGENCY RELEASE, THAT WHEN ACTIVATED WILL CAUSE THE GRILL TO RELEASE THE APPROPRIATE SMOKE REMOVAL SYSTEMS. NOTE******** -- THIS LIST IN NO WAY SHALL LIMIT THE RE SPONS15ILTY THE GENERAL CONTRACTOR TO ASSURE THAT ALL WORK IS DONE IN COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS OF THE CITY OF SANTA ANA. ON SITE INSPECTIONS OF WORK IN PROGRESS OR COMPLETION ARE STILL REQUIRED, AND MAY REVEAL ADDITIONAL WORK NEEDED OR CORRECTIONS. U-0N UNLESS OTHERWISE NOTED ARF ABOVE FINISHED FLOOR .�.�. ALIGN 'w, I ,E AT TENANTS EXPENSE N.T.S NOT TO SCALE N New EXISTING - TO REMAIN R move OR RELocare OCOLUMN NUMBER OROOM NUMBER 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS ON J05 SITE BEFORE START OF ANY CONSTRUCTION. ALL NOTED DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. 2. ANY DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF WILLIS DANIELS DESIGN. 3. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE STATE 4 LOCAL BUILDING CODE REQUIREMENTS, AND TRADE STANDARDS. 4. ALL AREAS TO RECEIVE MILLWORK SHALL BE FIELD MEASURED PRIOR TO FABRICATION. 5. ALL DRYWALL SHALL SE 5/8" TYPE 'X' GYPSUM BOARD AS REQUIRED ON WALLS AND CEILINGS, EXCEPT 5/8" WATER RESISTANT GYPSUM 50ARD WITHIN TOILET ROOMS AND JANITOR CLOSETS. 6. ALL METAL STUDS ARE 25 GAUGE. I C.5.0. 04036 UNLESS OTHERWISE NOTED. 1. CONTRACTOR TO FINISH SMOOTH ALL GYPSUM BOARD PARTITIONS TO ACCEPT PAINT. 8. CONTRACTOR SHALL INSPECT SLAB THROUGHOUT AND PREPARE SMOOTH SURFACE FOR CARPET OR VINYL COMPOSITION S. CONTRACTOR SHALL VERIFY WITH ALL EQUIPMENT RAWFACTURERS FOR EQUIPMENT ROUGH IN REQUIREMENTS. 10. CONTRACTOR SHALL PROVIDE ADEQUATE BACKING FOR ALL CABINET WORK AND WALL HUNG EQUIPMENT. 11. A MINIMUM EGRESS OF 44" CLEAR AISLE WIDTH SHALL BE MAINTAINED TO THE PUBLIC WAY. 12. CONTRACTOR SHALL SUBMIT (1) SEPIA AND (2) PRINTS OF ALL SHOP FABRICATION DRAWINGS FOR APPROVAL BY WILLIAM F. BURCH ARCHITECTS, INC. PRIOR TO EXECUTION OF WORK. 13. ALL WOOD FINISHING OF DOORS / MILLWORK TO 5E DONE OFF -SITE. 14. DIMENSIONS ARE FROM FINISHED FACE UNLESS OTHERWISE NOTED. IS. ALL PARTITION/FURRING INSULATION TO BE R-11 RATED. 16. CONTRACTOR TO SEAL ALL FIRE PENETRATIONS IN RATED CORRIDORS. 1-1. ENGINEERED DRAWINGS (ELECTRICAL/MECHANICAL/ FIRE SPRINKLER/FIRE LIFE SAFETY) TO 5E SUMMITTED TO 5UILDNG OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION OR FABRICATION. 1. EXIT DOORS SHALL SWING: IN THE DIRECTION OF EXIT TRAVEL WHEN SERVING ANY HAZARDOUS AREA OR WHEN SERVING AN AREA HAVING AN OCCUPANT LOAD OF 50 OR MORE. 2. EXIT DOORS SHALL BE OPENA5LE FROM INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. EXCEPTION: THIS REQUIREMENT SHALL NOT APPLY TO EXTERIOR EXIT DOORS IN A GROUP 45" OCCUPANCY IF THERE IS A VISIBLE, DURABLE SIGN ON OR ADJACENT TO THE DOOR STATING "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS." THE LETTERS SHALL BE NOT LESS THAN 1 INCH HIGH ON A CONTRASTING BACKGROUND. THE LOCKING DEVICE MUST BE A TYPE THAT WILL BE READILY DISTINGUISHABLE AS LOCKED. 3. PANIC HARDWARE WHEN INSTALLED, SHALL COMPLY WITH THE APPLICABLE BUILDING CODE REQUIREMENTS. THE ACTIVATING MEMBER SHALL BE MOUNTED AT A HEIGHT OF NOT LESS THAN 30 INCHES NOR MORE THAN 44 INCHES ABOVE THE FLOOR THE UNLATCHING FORCE SHALL NOT EXCEED 15 POUNDS WHEN APPLIED IN THE DIRECTION OF EXIT TRAVEL. 4. EXITS SHALL BE ILLUMINATED AT ANY TIME THE BUILDING IS OCCUPIED WITH LIGHT HAVING INTENSITY OF NOT LESS THAN i FOOT CANDLE AT FLOOR LEVEL. . 5. EXIT ILLUMINATION SHALL COMPLY WITH SECTION 133.0604 OF THE ELECTRICAL CODE. 6. EXIT SIGNS SHALL BE INSTALLED AT REQUIRED EXIT DOORWAYS AND WHERE OTHERWISE NECESSARY TO CLEARLY INDICATE THE DIRECTION OF EGRESS WHEN THE EXIT SERVES AN OCCUPANT LOAD OF 50 OR MORE. EXCEPTION: MAIN EXTERIOR EXIT DOORS WHICH 05VIOUSLY AND CLEARLY ARE IDENTIFIABLE AS EXITS NEED NOT BE SIGNED WHEN APPROVED BY THE BUILDING OFFICIAL. 1. THE CONTRACTOR PROVIDING THE SMOKE DETECTION AND BUILDING LIFE SAFETY SYSTEMS SHALL SUBMIT FIRE ALARM PLANS TO THE BUILDING DEPARTMENT FOR CHECKING AND APPROVAL PRIOR TO INSTALLATION. 8. WHEN NECESSARY, THE FINAL LOCATION AND QUANTITY OF EXIT SIGNS SHALL BE DETERMINED BY THE FIRE DEPARTMENT PRIOR TO CONSTRUCTION OF ANY WORK. 9. THE COLOR AND DESIGN OF LETTERING, ARROWS AND OTHER SYM50LS ON EXIT SIGN SHALL BE IN HIGH CONTRAST WITH THEIR BACKGROUND. WORDS ON THE SIGN SHALL BE IN BLOCK LETTERS 6 INCHES IN HEIGHT WITH A STROKE OF NOT LESS THAN 3/4 INCHES. 10. WHEN NECESSARY, THE FINAL LOCATION AND QUANTITY OF STR05E LIGHT LOCATIONS TO COMPLY WITH CODE AND TO BE DETERMINED BY THE FIRE DEPARTMENT PRIOR TO CONSTRUCTION. 11. THE COLOR AND DESIGN OF LETTERING, ARROWS AND OTHER SYMBOLS ON EXIT SIGN SHALL BE IN HIGH CONTRAST WITH THEIR BACKGROUND. WORDS ON THE SIGN SHALL BE IN 5LOCK LETTERS C6 INCHES IN HEIGHT WITH A STROKE OF NOT LESS THAN 3/4 INCHES. 12. ALL RATED CORRIDOR DOORS SHALL HAVE A THRESHOLD WITH A SMOKE AND DRAFT SEAL AT HEAD AND JAMBS. 13. INTERIOR WALL AND CEILING FINISHES SHALL BE NON-COi" 15UST15LE 'OR HAVE A FLAME SPREAD RATING OF 26 TO 15 OR LESS AT 1-HOUR CORRIDORS AND I6 TO 200 AT OTHER AREAS. 14. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A 10 BC WITHIN 15 FEET TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDING. 15. ALL DRAPES, HANGING CURTAINS AND OTHER DECORATIVE MATERIALS SHALL BE TREATED AND MAINTAINED IN A FLAME RETARDANT CONDITION. 16. ALL DOORS SHALL BE OPENA5LE BY A SINGLE EFFORT BY LEVER TYPE HARDWARE, UNLESS OTHERWISE APPROVED BY THE GOVERNING 5U ILD ING CODE. 11. EXTEND SPRINKLERS AND FIRE / LIFE SAFETY AS REQUIRED. DANIELSWILLIS 1016 Prospect Avenue Hermosa Beach California 90254 MOW Ibb • • • • � IIIIC� 1 • 1 r 2mO PAGE 2 OF 9 0 WILLIS WILLIS DANIELS 1016 Prospect Avenue Hermosa California 90254 310.379.3738 310.594.6989 cell 310.379.0752 i T" DOCUMENTATION0 : WILLIS DANIELS ISSUE DATE: September 11, 2003 0 October 29, 2003 my PAGE 3 OF 9 WILLIS WILLIS DANIELS 1016 Prospect Avenue Hermosa Beach California 9i 310.379.3738 310.594.6989 cel' 310.379.0752 fax a a a a r � l DOCUMENTATION. WILLIS DANIELS ISSUE DATE. September 11, 2003 SCALE: 1/411 =1'-0" ymizweims WILLIS WILLIS DANIELS 1016 Prospect Avenue Hermosa Beach California 90254 Nub 441 - II • 4R4 DOCUMENTATION: WILLIS DANIELS ISSUE DATE: September 11, 2003 SCALE: If . 1 1=011 1/4 � Aul WILLIS WILLIS DANIELS 1016 Prospect Avenue Hermosa Beach California 90254 1 1 1 -4 s REFLECTED CEILING PLAN DOCUMENTATION0 : WILLIS DANIELS ISSUE DATE: September 11, 2003 October 29, 2001 SCALE. 1/411- 11.011 ,' • d ce Rej We FIN16H LEGENED WILLIS CARPET THRU-OUT U.O.N. - SPECS TO FOLLOW. CT 12" x 12" CERAMIC TILE - COLOR TO FOLLOW. PLI PLASTIC LAMINATE - "WILSONART" OR EQUAL COUNTER TOPS - COLOR TO FOLLOW. PZ ACCENT PAINT - ICI RED - COLOR TO FOLLOW. MS GALVANIZED CORRUGATED METAL SIDING. SPAINTED SLO7lUALL - RlLI. HEIGHT -COLOR TO FOLLOW CD CHAIN LINK FENCING FROM 4'-0" A.F.F. TO FINISH CEILING. ,4C 1/4" COLORED PLEXIGLASS PANELS - COLOR TO FOLLOW. ALTERNATE PRICING FOR SHOP PAINTED MASONITE. -- PAINT THRU-OUT WITH ICI EGGSHELL PAINT COLOR TO FOLLOW. -- PROVIDE SURKE 4" RU55ER SASE OR EQUAL THRU-OUT = COLOR TO FOLLOW. 1 � 1 DANIELSWILLIS 1016 Prospect Avenue :iermosa Beach C�alifornia 90254 310.379.3738 310.594.6989 cell 310.379.0752 F-IN15H NOTE5 �ti a o = Q 'cc c� 3YP3UM BOARD CEILING tt-IRU-OUT.cc � O 0 Cc Alma cr 0 i (D (n L cc c 4)co � N FINISH PLAN DANIELSDOCUMENTATION WILLIS 0 ISSUE DATE. September 11, 2003 0 October 2' 2003 0 SCALE. 1/ 4 i 11 700' PAGE 7 OF 9 G*1P51JM 50ARD ENTR"'r CLEA /AL U1"-1 IN Ut*-1 -- WITH 1/4II COLORED REINFORCING CLIP G'*T 5U1"C 50ARD ENTR`r ACR*1`LIC PANEL FACING (T*rf=ICAL) _ — WITH 1/4" COLORED PLEXIGLASS PANEL FACING 1 3/4" x 3/4" CONTINUOUS _ "W" 5L- ACK 1" 1E TAL- CHANNEL r% ..: <: ::.y:?. .... :.: ;• •i•:: ?;:::•. �•.?',::.,+ •.? CORRUGATED 1/2" �' P R D METAL 5HE,4TING A2/ GLASS IN FRXIE F_ 1" 5,45E 1"11=TAL FRAt* 1E e OFEN o OPEN . m (2) 24' X 3(o" RECESSED 1/2 " T PERED 1/2 " TE PERED 1/2 " T PERED mv POSTER 5OXE6 GLASS- I FRAME GLASS 11,,%4 FR,41"1E GL A55 I FRAME (O" GALVANIZED 5,45E 4" CLEAR AU1" IINU1`°1 SHOE TOP AND 50TT01" I 1"IETAL- 3,45E A INTERIOR ELEVATIO 3/4" x 3/4" CONTINUOUS "W" 5L ACK METAL CHANNEL TRUCTURE A50VE LANDLORD C *rf=5U1" 1 50ARD ENTR�I' SCREW TOP TRACK TO NEUTRAL PIER 1 it 3,45E METAL FRr4ME WITH 1/4" COLORED PLEXIGL,4S5 e a a e° < .p.`/1,4�yCywsyONA/y�L/�_i5RACEREWS g Wf WO (2 PANEL FACING CHAIN L I1�lfC. ° ° SECURE W/ 1" POWER DRIVEN PIN O 1-IILTI OR EQUAL CORRUGATED FENCING 12-1/2" METAL STUD DIAL. 5RACING 1"I �,� L 5 a-i ,4 I I�IG -� 4' -0" OZ. STA sERED AS REQ'D. FASTENED TO STRUCTURE A50VE CORRUGATEDEXISTING GYPSUM BOARD CEILING 1 ,4 G R� L I C 5HEATING TOP TRACK, HILTI OR EQUAL, IC50 0 441S (WHITE) 2-1/2 MTL STUDS 25 GA� 2 -O O.C. W/ 1 /2 " T E PE RE D 1 /2 " TEMPERED 5/8" TYPE "x" GYP. 50ARD ON EACH SIDE. GLASS I FR�4ME GL�4S5 I 1=R-',4ME � UNITED SUPPLY OR EQUAL. AS PER ToP AN 50TTOM ToP AN 50TTo>"I l OPEN y! ° _ . � SLOT WALLle -- (:C.E3A. 'M562/3206 REF. USC tA5LE 15 16-1.1 FOR ADD'L INFORMATION Ilk 0 o BOTTOM TRACK ANCHORED* 2'-0" O.C. WITH 3/16" DIAMETER RED HEAD FAST- ENERS, ITW RAMSEY/ RED HEAD OR EQUAL. IC150 M312 CLEAR, ALU1",1INU1"*1 15ASE (SEE FINISH SCHEDULE) RE INFOR f NG CLIPS . V .���=r FINISHED FLOOR C T1'P I >4LLANNING DIVISIONa a...°'. a. e .�' 4 ! STE a.: d a 4 ° 4. ..° . °.a P. Y nO i TqrV a INTERIO E TION 3/Soy G INTERIOR ELEVATION. TYPE "A" PARTITION Sca Ise- N.T.S. DATA EXISTING MALL 5ULKHEAD j4 NO BUILDING STANDARD 3/4' "W" REVEAL d ° 4 d <. . < ° _ — CONCRETE SLAM AWVE J . - ill SASE METAL TRIM CAULKING SMOKE/FIRE DAMPER ON DUCT AT ALL PENETRATIONS. 4� N (714) 7- 7 `• GALVANIZED CORRUGATED 0 O : METAL PANEL "X11 5/8" TYPE GYPSUM 50ARD OVER METAL STUDS �— EXISTING C:YPwi 5oARD CEILING METAL HEAD TYP. (50TH SIDES) 7777777 a? — EXISTING GYPSUM 2-1/2" MTL STUDS 25 GA. 2'-0" O.C. W/ 5/8" TYPE "X" GYP LAIRD ON EACH SIDE. STORE FRONT ALLIMINUM SECURITY GRILLE TR4CK INSTALLED 5Y OTHERS ALUMINUM SECURITY GRILLE TRACK 7 50ARD CEILING UNITED SUPPLY OR EQUAL. AS PER *3108. 5/8" TEMPERED GLASS PLE IGLAss LARR 245i1 I IG1`30 FIRE IN CLEAR ALUMINUM GLAVANIzED CO�:REGATED O O AND SAND SMOOTH MOTH SIDES FROM DECK TO DECK, FRAME 5/8" TYPE "X" — 1/4" COLORED �� 1/4 COLORED PLEXIGLASS PANELS �� �� �� MET L P L O R 5/8 TYPE X.19 GYPSUM 5OARD STANDARD BULL HEIGHT : _ I.C.BA. M562/3206 REF. UC5 TABLE '1�3 .. GYPSUM BOARD PLEXIGLA55 PANELS OVER 25 GA STUDS (FULL HEIGHT) GULL HEIGHT) OVER 25 GA STUDS DEMISING WALL 16-1.1 FOR ADD L INFORMATION 5oTTOM TRACK ANCHORED 2'-0" O.C. WITH 3/16" DIAMETER RED HEAD FAST- L-41-1 ENERS, ITW RAMSEY/RED HEAD OR EQUAL. o IC50'M312/LARR 20333 15ASE (SEE FINISH SCHEDULES FINISHED FLOOR a a. ° a e < a ,. d d ° n ° ° .• AL ALUMINUM ROLL —DOWN SECURITY GRILL ENTRY Sca Is: I.T.S. STANDARD DEMISING WALL Sca Is: N.T.S. Sca I s N.T.S.GSECT I ON ATENTRY Sca Is: �...n WILLIS 1 WILLIS DANIELS 1016 Prospect Avenue Hermosa Beach California 90254 ! • • • • 00 DETAILS 00 DOCUMENTATIONs WILLIS DANIELS ISSUE DATE: September 11, 2003 �i October 29, 2003 0 Oz November 7, 2003 SCALE: As Noted PAGE 8 OF 9 � c< WILLIS J CD] O SUSSED CLGs. CONSTRUCTION AS PER I C.B.O.1P 2240 BRAG I NCB DETAIL N.T.5 r,.;:! „mom_ • ' " *8 WAGE HAI�FER WIRES SPACED 4'-0" O.C. ALONG 1 1/2: METAL CHANNELS. LOCATE WITHIN 8" OF ENDS OF= CH,4NNEL. RUNS. 11/2" STEEL CHANNEL ! 4'-O" O.C. PROVIDE 1" CLEARANCE r BETWEEN ABUTTING WALLS AND PARTITIONS. AT CHANNEL SPLICES, INTERIOR LOCK FLANGES, OVERLAP ENDS 12" AND SECURE EACH END WITH DOUBLE STRAND 18 GA. TIE WIRE. METAL FURRING CHANNEL WITH 1" CLEARANCE BETWEEN FURRING ENDS AND A5UTTM WALLS AND PARTITIONS. ATTACH FURRINGs CUMELS TO A 1/2" CHANNEL WITH FURRING CHANNEL CLIPS INSTALLED ON ALTERNATE SIDES AT SPLICES, NEST FURRINGS CHANNELS WITH AT LEAST 8" OVERLAP AND SECURELY WIRE TIE EACH END WITH DOUBLE STRAND 18 GA. TIE WIRE. LATERAL SUPPORT WIReES, +12 GA. (MIN) SPLAYED IN FOUR DIRECTIONS SO DEGREES APART. CONNECT TO 1 1/2" STEEL CHANNEL 9 6" MAX. FROM CROSS FURRINCs CHANNEL TO STRUCTURE A13OVE AT AN ANGLE NOT EXCEWWs 45 DEGREES FROM PLANE OF CEILINGS. INSTALL LATERAL SUPPORT WIRES s 12'-0" INTERVALS EACH DIRECTIONS WITH THE FIRST POINT 04'-0" (MAX) FROM EACH WALL. 5/8" TYPE 'X' GsYPSUM BOARD. Not to Scale DANIELS DESIGN WILLIS DANIELS 1016 Prospect Avenue Hermosa Beach California 90254 310.379.3738 310.594.6989 cell 310.379.0752 fax i Y i DANIELS1..10C UMENTATIONm WILLIS '-�SSUE DATE: September October 29, 2003 SCALE: As Noted PAGE 9 OF 9